UTG Shut-off, Balancing And Gas Damper UTG equipped with pneumatic actuator, junction box and solenoid valve Halton UTG dampers are used to shut-off and balance • Outer frame of galvanized, painted or stainless steel. airflow rates in high pressure ductwork. Dampers meet Blades of galvanized or stainless steel with double international standards for rectangular and round ducts. sheet construction, silicon sealings. Maintenance- In the open position, the blades face the direction of free stainless steel bearings and shafts. flow and do not cause a significant pressure loss. • Electrical, pneumatical or manual operation system The UTG is used as a shut-off, gas and balancing available damper in applications where tightness and reliability • UTG dampers can be supplied with connection are important. pieces for round duct • Maximum duct pressure for damper construction • For shut-off and balancing of air intake and exhaust 5000 Pa and maximum air velocity 15 m/s. In case of • ATEX approved. Shock tested. high duct pressure, contact Halton Marine for finding • Closed damper fullfils the requirement of leakage up the most suitable solution. to class 3. Details available from Halton. • Classification of casing leakage EN 1751 class B PART MATERIAL FINISHING Frame Carbon steel Painted or galvanised Frame Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) - Blades Steel Galvanized Blades Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) - Maintenance-free bearings Stainless steel EN 1.4404 (AISI316L) - Shafts Stainless steel EN 1.4404 (AISI316L) - UTG - Shut-off, Balancing And Gas Damper 1 UTG DIMENSIONS AND MATERIAL THICKNESS Actuator effect on dimensions UTG shut-off, gas and balancing dampers meet ACTUATOR international standards for both rectangular (width DIMENSIONS R B 100-1200 mm and height H 100-1600 mm, 1 mm division) and circular ducts (Ø100-1250 mm). Nonstandard dimensions are available on request. Standard flange width 27 mm. Flanges and drilling also available according to ISO 15138 standards. Modular construction sizes available up to 2400X3200 mm. Frame thicknesses from 3 mm to 10 mm. Standard A Manual Handle 95 H Electrical GGA 326.1E 100 H<300 = 300 H>300 = H Pneumatic PNL Linear actuator 245/300 N 170 H<500 = 500 H>500 = H Pneumatic PNR Pneumatic rotating actuator AT100 170 H<300 = 300 H>300 = H Pneumatic PNR Pneumatic rotating actuator AT200 190 H<350 = 350 H>350 = H GENERAL UTG DRAWING UTG CIRCULAR CONNECTIONS ØD H+4 H+58 n*150 150 10 n*150 MIN. 50 150 n*150 B+4 10 R n*150 150 ACTUATOR 150 MIN. 50 18 30 10 Ø1 2 The above table contains only some examples of actuators and their effect on dimensions. A frame thickness is 3 mm. 10 B+58 361 UTG CIRCULAR, WITH CONNECTION FLANGES ØD 240, BLADES IN OPEN POSITION 210 160 3 GENERAL UTG DRAWING, TOP 367 UTG - Shut-off, Balancing And Gas Damper 2 B / Width (mm) H / Height mm 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 100 200 300 400 500 600 700 800 900 1000 1100 1200 4 6 8 10 13 15 17 19 21 23 26 27 30 32 34 36 6 8 10 12 15 17 20 22 24 26 29 31 33 35 38 40 7 9 12 14 17 19 22 24 27 29 32 34 37 39 42 44 9 11 14 16 19 21 25 27 30 32 35 37 41 43 46 48 10 13 15 18 21 24 27 29 33 35 38 41 44 47 50 52 12 14 17 20 23 26 29 32 36 38 42 44 48 50 54 56 13 16 19 22 25 28 32 35 38 41 45 48 51 54 58 60 15 17 21 23 28 30 34 37 41 44 48 51 55 58 62 65 16 19 22 25 30 33 37 40 44 47 51 54 58 61 66 69 17 21 24 27 32 35 39 43 47 50 55 58 62 65 70 73 19 22 26 29 34 37 42 45 50 53 58 61 66 69 74 77 20 24 28 31 36 39 44 48 53 56 61 64 69 73 77 81 D2 Ø D Weight mm kg 7 100 8 125 11 160 12 200 17 250 19 315 26 400 34 500 44 630 59 800 80 1000 110 1250 Examples of actuator weights: UTG-EL GGA 326.1E 2,3 kg, GNA 326.1E 1,3 kg, BF230 +3,2 kg, BLF230 +1,7 kg, ExMax/Redmax +3,5 kg, CSQP +3 kg, UTG-PNR AT100 +2,1 kg, AT100 as AISI316 4,4 kg, AT50 1,2 kg, UTG-PNL Roder +4 kg, UTG-MAN + 1 kg. Control enclosure +4 kg. UTG-EL WIRING DIAGRAM with Belimo actuator UTG-EL WIRING DIAGRAM with ExMax or RedMax actuator POWER SUPPLY 24, 120, 230 VAC 24 VDC L/+ N/- DAMPER CLOSED 1 DAMPER OPEN 2 3 4 DAMPER CLOSED POWER SUPPLY 24-230V AC/DC L/+ N/- PE 1 4 3 M16 M20 N/- 1 3 2 4 PE 1 2 3 4 5 6 7 8 9 10 11 S2 S3 S4 S5 N/- 1 3 2 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PE -EARTHING RAIL S1 END CLAMP 1 2 3 4 5 6 7 8 9 10 11 2(BN) 1(BU) L/+ END CLAMP L/+ M20 S6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 3 2 5 4 1 1 3 2 4 5 END CLAMP M20 END CLAMP DAMPER OPEN 2 6 PE M16 M16 M16 M20 2 x 0,75 mm² 6 x 0,75 mm² 1 2 M S1 5° S2 M20 6 x 0,5 mm² S3 S4 S5 80° S6 WHEN DAMPER IS NOT ENERGIZED CONTACTS S1-S2, S4-S5 ARE CLOSED BELIMO BF24 BF120 BF230 BLF24 BLF230 PE 2 3 5 HEATER IP54 UTG - Shut-off, Balancing And Gas Damper 3 6 x 0,5 mm² 1 4 1 5° 2 3 4 5 6 85° WHEN DAMPER IS NOT ENERGIZED CONTACTS S1-S2, S4-S6 ARE CLOSED ExMax-5.10-SF RedMax-5.10-SF ExMax-15-SF RedMax-15-SF IP66 V6M09Y2015/Halton Marine reserves the right to alter products without notice. WEIGHTS OF STANDARD HALTON MARINE UTG DAMPERS (KG) without an actuator UTG-EL WIRING DIAGRAM with Elodriveactuator POWER SUPPLY 24V AC/DC 120/230 V AC L/+ N/- DAMPER CLOSED 1 UTG-PNR/PNL PNEUMATIC DIAGRAM DAMPER OPEN 2 OPTION: LIMIT SWITCHES 4 3 CLOSED 21 13 21 13 OPEN 22 14 13 14 JUNCTION BOX S6 S5 3 6 M16 M16 6 LIMIT SW M 87° 3° 1 2 N L1 3 5 24/220 V 6 3 6 IP 54 8 6 OPTION: SOLENOID VALVE 3 PORT/2 WAY BELIMO BF24 / BF120 / BF230 BLF24 / BLF230 ELODRIVE CSQP-05A1E CSQP-05A2E CSQP-10A1E CSQP-10A2E CSQP-15A1E CSQP-15A2E 6 3 DAMPER OPEN LIMIT SW S6 DAMPER CLOSED S5 S4 S3 S2 2 S1 1 3 x 0,75 mm² 12. SPEED CONTROLLER 10 OPTION: MANUAL VALVE 3 PORT/2 WAY 14 11. PRESSURE REGULATOR 8 6 FUSIBLE LINK OPTION: 13 50/74/100°C 13 10. OPTION: MANUAL VALVE 4 M16 14 8 6 FUSIBLE LINK VALVE 3 PORT/2 WAY THERMAL FUSE SM-072-A0-2A (72°C) M16 9. OPTION: OPEN / CLOSED SWITCHES PIPELINES:POLYAMIDE 14 8 9 10 11 M16 8. PLASTIC TUBE. OPTION: STAINLESS STEEL 2 QUICK EXHAUST VALVES 3 M16 6. MALE CONNECTOR 4 END CLAMP 4 3 7 S4 12 4 3 3 (-) 2END CLAMP S3 4 5 6 13 5. OPTION: SOLENOID VALVE 7 1 M16 2 1 3. SILENCER 7. DOUBLE NIPPLE 1 2 3 4 5 6 7 8 9 10 11 3 2. QUICK EXHAUST VALVE 1 3 SPEED CONTROLLER N/- 9 4. FUSIBLE LINK VALVE DAMPER OPEN 1 2 3 4 5 6 7 8 9 10 11 S2 3 2 L/+ 2 S1 2 1 1 1 (+) M20 SPRING RETURN ACTUATOR M16 2 1 AC24VM20 DC24...48V AC120V DAMPER AC230V CLOSED (-) (+) 1. SPRING RETURN VALVE 22 14 8 PRESSURE REGULATOR 6 11 PNEU. INLET (5 - 8 BAR) IP66 T - ~ + FOR A PLASTIC TUBE Ø6 MM AC24V UTG-EL WIRING DIAGRAM with Siemens actuator DC24...48V DAMPER CLOSED 3 DAMPER CLOSED 2 1 POWER SUPPLY 24, 120, 230 VAC 24...48 VDC L/+ N/- M20 1 DAMPER OPEN 2 3 M20 JUNCTION BOX S6 S5 S4 2 3 4 5 6 7 8 2 3 5 1 4 9 10 11 12 13 14 15 8 9 10 11 7 N/- PE 1 (-) 4 3 2 L/+ S3 4 5 6 S2 (+) 1 M20 4 JUNCTION BOX M16 3 S1 1(3) 2(4) 2 CLOSED AND OPENED INFORMATION OUT M16 M20 1 24....230 VAC/DC (+)(-) PE ~ ~ DAMPER OPEN 4 AC120V AC230V (-) (+) 1 THERMAL FUSE SM-072-A0-2A (72°C) 3 2 PE BK BE BN S1 S2 S3 S4 S5 S6 4 S3 M16 2 x 0,75 mm² S5 S6 FUSIBLE LINK OPTION: 50/74/100°C M16 87° 3° S4 M20 M16 SIEMENS GGA.126.1E/HA GGA226.1E/HA GGA326.1E/HA GNA126.1E/HA GNA326.1E/HA IP 54 6 x 0,75 mm² FUSIBLE LINK OPTION: 50/74/100°C (BARTEC) PE 2 1(3) 2(4) M S1 5° M20 S6 S2 S5 S4 S3 S2 S1 1(3) 2(4) S1 M20 BROWN 1 2 3 4 5 6 7 8 9 10 11 BN BU 1(3) 2(4) M M16 BLUE M16 BLACK M16 END CLAMP END CLAMP 1 2 3 4 5 6 7 8 9 10 11 S2 S3 S4 S5 80° S6 WHEN DAMPER IS NOT ENERGIZED CONTACTS S1-S2, S4-S5 ARE CLOSED SIEMENS GGA.126.1E/HA GGA.226.1E/HA GGA.326.1E/HA GNA.126.1E/HA GNA.326.1E/HA 3 5 1 4 S1 S2 S3 S4 S5 S6 Schischek 5° IP54 UTG - Shut-off, Balancing And Gas Damper 4 85° IP 66