OAC-P, MicroSet PIR Ceiling Sensor Line Voltage

advertisement
Type
Catalog #
Project
Comments
Date
Prepared by
OAC-P,
MicroSet PIR
Ceiling Sensor
Line Voltage
PIR
Activated
MicroSet
Self-Adjusting
• MicroSet self-adjusting Time Delay
and sensitivity
• Units available for control of single or
two separate loads
• NEMA WD7 Standard robotic method
utilized to verify coverage patterns
Specifications:
Technology: Passive Infrared (PIR)
Power Requirements:
120 to 347 VAC, 50/60 Hz - Neutral Required
120 VAC:
• Incandescent/Tungsten - 0 to 800W, 50/60 Hz
• Fluorescent/Ballast - 0 to 1200W, 50/60 Hz
• Motor Load: ¼ HP @ 125 VAC
230 VAC:
• Fluorescent/Ballast - 0 to 1200W, 50/60 Hz
277 VAC:
• Fluorescent/Ballast - 0 to 2700W, 50/60 Hz
347 VAC:
• Fluorescent/Ballast - 0 to 1500W, 50/60 Hz
Time Delays: Self-adjustable, 15 seconds/test (10 min.
Auto), or Selectable 5, 15, 30 minutes
Coverage: 500 and 1,500 sq. ft.
Light Level Sensing: 0 to 300 foot-candles
Operating Environment:
• Temperature: 32°F - 104°F (0°C - 40°C)
• Relative humidity: 20% to 90%, non-condensing
• For indoor use only
Housing: Durable, injection molded housing.
Polycarbonate resin complies with UL 94V0.
Size: 4.5”H x 1.42”W (114.3mm x 36.068mm)
LED lamp: Red LED for Passive Infrared
Warranty: Five year
Overview
The MicroSet Passive Infrared Line Voltage Occupancy Sensing Ceiling Sensor is a
motion sensing lighting control that is used for energy savings and convenience. The
sensor is available in both single and dual load control.
Operation
The sensor is designed to detect motion from a heat-emitting source (such as a
person entering a room) within its field-of-view and automatically switch lights ON.
These sensors have multi-segmented lenses. For units to sense motion, the person
must cross between two segments. The distance between segments increases the
farther you are from the sensor, so motion has to be larger the farther you are from
the unit. PIR sensors are considered line-of-sight sensors, meaning that the sensor
must be able to have a direct line-of-sight to the person making the motion. The
sensor includes self-adaptive technology that continuously self-adjusts sensitivity
and time delay in real-time, maximizing the potential energy savings that are
available in the particular application. The MicroSet Passive Infrared Line Voltage
Ceiling Sensor has an ambient light level sensor. When enabled, the daylighting
feature prevents lights from turning ON when the room is adequately illuminated by
natural light.
Applications
conference rooms
common areas
open office areas
break rooms
small private offices
restrooms (non-partitioned)
Ordering
Catalog #
Recommended Room Size
Field of View
OAC-P-0500-MV
500 sq.ft.
360°
OAC-P-0500-DMV
500 sq.ft.
360°
Dual Relay w/Daylight Sensor
OAC-P-1500-MV
1,500 sq.ft.
360°
w/Daylight Sensor
OAC-P-1500-DMV
1,500 sq.ft.
360°
Dual Relay w/Daylight Sensor
FCC Compliant
cULus Listed
RoHS Compliant
www.coopercontrol.com
utility closets
203 Cooper Circle
Peachtree City, GA 30269
P: 800-553-3879
F: 800-954-7016
Features
w/Daylight Sensor
Occupancy Sensors - Ceiling Mount
• Built-in light level sensor
OAC-P, MicroSet PIR Line Voltage
Wiring Diagrams
One Sensor, One Load (-MV units)
One Sensor, Two Loads (-DMV units)
120-347 VAC
Line
120-347 VAC
Neutral
Line
Neutral
Black
White
Blue
Red
Red
Load 1
Black
Blue
White
Load 1
Load 2
Red leads are non-polorarity sensitive.
Coverage
OAC-P-1500-MV/DMV
OAC-P-0500-MV/DMV
1,500 sq. ft.
500 sq. ft.
7 ft
(2.13 m)
20 ft
(6.096m)
5 ft
(1.5 m)
15 ft
(4.57 m)
10 ft
(3 m)
0
5 ft
(1.5 m)
0
DT1k
5 ft
(1.5 m)
5 ft
(1.5 m)
7 ft
(2.13 m)
10 ft
(3 m)
8.5 ft
(2.59 m)
3 ft
(0.91)
0
15 ft
(4.57 m)
0
7 ft
5 ft
(2.13 m) (1.5 m)
20 ft
(6.096m)
8.5 ft
(2.59 m)
Minor Motion, IR
3 ft
(0.91)
0
The NEMA WD 7 Standard and robotic
method were utilized to verify
coverage patterns.
Major Motion, IR
20 ft
(6.096m)
15 ft
(4.57 m)
10 ft
(3 m)
5 ft
(1.5 m)
0
5 ft
(1.5 m)
10 ft
(3 m)
15 ft
(4.57 m)
5 ft
7 ft
(1.5 m) (2.13 m)
Maximum coverage area may
vary somewhat according to room
shape and the presence of obstacles.
20 ft
(6.096m)
Recommended Mounting Height: 8 to 12 feet
Controls
Not Used
LEDs
Override
Daylighting
Not Used
Bathroom Mode
Relay Swap
Relay 2
Relay 1 & 2
(DMV model only) (DMV model only) (DMV model only)
Daylight Sensor Adjustment
PIR Detector
ON
1 2 3 4 5 6
www.coopercontrol.com
203 Cooper Circle, Peachtree City, GA 30269
P: 800-553-3879 F: 800-954-7016
ACC120012
7 8 9 10 11 12
Cooper Controls, Greengate, Novitas, Yes Box, PCI Lighting Control Systems, VisionTouch, VisionSwitch,
MicroSet, Digita, ControlKeeper, LiteKeeper, Revio, Ineo, TracKeeper, IntelliRelay are valuable trademarks
of Cooper Industries in the U.S and other countries. You are not permitted to use Cooper Trademarks
without the prior written consent of Cooper Industries.
Download