Centrifugal Fans AT belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0180 to 0560, ADH and RDH fans of the L, R, K, K1 and K2 versions, from sizes 0630 to 1000, AT fans of the S, SC, C and TIC versions, from sizes 7/7 to 30/28, shown herein are licensed to bear the AMCA Seal. Nicotra Gebhardt GmbH (Germany) certifies that RZR fans of the 11, 12, 15 versions, from sizes 0355 to 1000, shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Air performance with Installation Type “A” (“with free outlet”), and that of the twin fan versions G2L, G2R, G2K, G2K2, G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2, and that of the triple fan versions G3C and G3C-C2 in any installation type is not AMCA licensed. Nicotra Gebhardt stands for: A Maximised flexibility and minimised design effort for customers, because all radial fan casings have identical dimensions – no matter what kind of impeller geometry A Top product quality and shorter delivery times – thanks to state-of-the-art production technology A Energy efficiency through comprehensive system know-how I The Nicotra Gebhardt portfolio A strong provider for many optimal solutions When it comes to radial fans, we are the first people you should talk to. From belt-driven radial fans to plugfans, it’s all there in our product portfolio. We offer the largest, most comprehensive range of products in this area – and of course the matching services. ADH-E / ADH AT RDH-E / RDH RZR double-inlet forward-curved impeller geometry double-inlet inch diameters forward-curved impeller geometry double-inlet backward-curved impeller geometry double-inlet hollow aerofoil impeller geometry When everything fits To us, perfection in our product portfolio means that all product series in the area of encased radial fans are attuned to one another and are 100% compatible in their dimensions. How did we do it? By using an identical design for the connection dimensions of every fan size in our newly developed series ADH-E and RDH-E and carefully coordinating our options and accessories. In this way, we have standardised and harmonised our product portfolio in all relevant areas. Well designed, easy to install, economical A system that saves space, time, and money – in an air handling unit or any other application: our compact base frame offers decisive advantages: A The frame lengths have been optimised and adjusted for the casing position and motor installation height to achieve the smallest possible overall height and length A Exact, optimised coordination of all components, all the way through to installation, adjustment and testing A Suitable for all fans of the series ADH-E0, RDH-E0 and RZR-11 up to size 0500 II The compact base frame from Nicotra Gebhardt proSELECTA II Simple and reliable selection proSELECTA II is a technical selection program that allows you to configure your own individually designed fan. It provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proSELECTA II is the provision of all the technical data for your fan, including sound level data, dimension specifications and accessories. Apart from that, as a registered user, your purchase prices are provided. Additionally fully dimensioned drawings in DXF format are available, which can be downloaded and transferred straight into your CAD system. So that you can be sure Models and options that are technically not permissible, are automatically excluded in proSELECTA II. So there is no chance that you will configure a “wrong” device option. What else is important to you During the fan selection process, you can choose any of the standardised ATEX options. Free registration and many advantages You can register as a proSELECTA II user with us, which enables us to offer you faster order processing. What this means for you is: A The complete configuration of your fan with its associated system accessories and belt drive layout. A The possibility to produce fans that operate via a frequency inverter. A The option of saving your own fan configuration on our server. A The opportunity to modify your saved configuration, even over the phone to your Nicotra Gebhardt representative. 2 A Volume up to 300,000 m³/h A Pressure up to 2,200 Pa ADH High performance centrifugal fan ADH double inlet for belt drive impeller with forward curved blades of galvanised sheet steel A Volume up to 65,000 m³/h A Pressure up to 2,500 Pa AT High performance centrifugal fan AT double inlet for belt drive impeller with forward curved blades of galvanised sheet steel A Volume up to 290,000 m³/h A Pressure up to 3,500 Pa RDH High performance centrifugal fan RDH double inlet for belt drive centrifugal impeller with backward inclined blades A Volume up to 300,000 m³/h A Pressure up to 3,500 Pa RZR High performance centrifugal fan RZR double inlet for belt drive high performance impeller with backward curved hollow section true aerofoil blades Fittings / Accessories Accessories Ac omplete system accessories Am iscellaneous fittings Description 3 Description A technical description A operating limits The Nicotra Gebhardt best-sellers, simply! The series AT Fans of AT series don’t need any presentation: they have been one of the main strengths in the Nicotra Gebhardt product range for over 35 years and have long been appreciated for their unequalled combination of compactness, efficiency, quietness of operation and versatility, at an extremely affordable price. News How we can improve a perfect fan? We tried, anyway: we developed a new seaming process, to join the back plate to the side plates with a fully automated process. The result is a new scroll without welding and whatever can become rusty, also providing a better structural strength to vibrations. And, since we like to be coherent, we even deleted welding of the side frames, which are now screwed to scrolls, and from spars, now riveted. Searching for excellence Who have say that a product with a nice price cannot be a nice product? The success of the AT series confirm is the real proof: the bearings have been selected to achieve, at maximum load and with suitable pulleys, a bearing life of 40.000 hours, a number that can be considerably greater in more common load conditions. Top quality materials, innovative technology of scroll and impeller manufacturing and assembly, high efficiency, options and accessories, everything has been chosen to provide a long operating life time, with the maximum quietness and safety. Complete range Aren’t you convinced? Have a look to the range of the AT fans, you immediately realize that, as far as we can, we’re doing our best to try and meet all your requirements. We have single, twin and triple fans, with or without side frames, with one, two or three bearings for light or heavy duty, we have versions with hollow shafts, when there is the need of reducing the weight without reducing the fan performance, and also spark-proof versions. Do you still think that we don’t have the right fan for you? 4 Product overview range AT This kind of fans are specially conceived for mechanical ventilation, at temperatures from -20 °C to +40 °C on S, SC, G2L and SC2 models, or up to 100 °C on AR, TIC, G2C, G2C-C2, G3C, G3C-C2 models. Air performance and sound data have been obtained in a laboratory registered by AMCA for AMCA 210/99 air performance testing and they are within the tolerances allowed by the DIN 24166 standard for Class 2. Single, twin and triple fans Impeller size (diameter/width) from 7/7 to 30/28 Lap-jointed scroll of galvanized steel assembled with roller-lock seaming (sizes up to 18/18) or with Pittsburgh lock seam (for sizes larger than 18/18) Straight cut off plate at fan outlet Impeller with forward curved blades of galvanized steel, optimized for the best efficiency and quietness Galvanized steel shaft Single, twin and triple fans. Airflow up to 180.000 m³/h Total pressure up to 1.400 Pa The variety We have the right fan for all your applications! Depending on the fan size, five single fan versions, four twin fan versions and two triple fan versions are available in the AT range. Version Description AT S Light construction, without feet and outlet flange.Light-duty bearing and pressed steel bearing supporting brackets. AT SC With rectangular side frame and without outlet flange.Light-duty bearing and pressed steel bearing supporting brackets. C version has also three steel bars with the ends welded to three corners of both the side frames. AT AR With heavy duty reinforced side frames, joined by three steel bars in three corners and without outlet flange. Medium duty bearing inside lubricatable, cast iron pillow block, mounted on a robust cross-bar. AT TIC With heavy duty reinforced side frames, joined by four steel bars in four corners and without outlet flange. Medium-heavy duty bearing inside lubricatable, cast iron pillow block, mounted on a robust cross-bar. Version Description AT G2L Two S-version single fans joined together by three U-section spars. The two impellers are mounted on a common shaft, supported by three bearings. AT SC2 Two SC-version single fans joined together by three L-section spars. The two impellers are mounted on a common shaft, supported by three bearings. AT G2C Two single fans mounted side-by-side inside a common supporting frame of three L-section spars. The two impellers are mounted on a common shaft, supported at the ends by just two bearings.Use of hollow shafts on the larger sizes. AT G2C-C2 Figure Figure Mechanically similar to G2C fans but stronger, thanks to the use of hollow shafts with larger diameter (45 mm) journals and plummer blocks with heavy-duty bearings. 5 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 7/7 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 200 mm 46 0.009 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 1.25 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2000 59 3.0 56 2.2 42 1.5 48 1.1 % kW 40 1500 54 ηr Pa 4.0 0.75 29 0.55 1000 0.37 800 0.25 600 95 dB 0.18 500 400 0.12 90 300 0.06 200 0.04 85 150 0.01 300 0.06 19 17 17 2400 16 16 2200 15 15 2000 13 13 1800 12 12 1600 11 11 1400 9 9 1200 8 8 1000 7 7 800 5 5 700 5 5 600 4 4 A7 LW Normal operation area 400 0.08 500 600 0.1 65 800 N 1000 1500 0.2 2000 0.4 3000 0.6 4000 5000 0.8 1 m³/h Measured in m³/s installation B according to 1.4 0.6 0.8 1 pd2 2 2 ∆LWrel4(A) 6 70 SX 200 0.9 1 v2 Speed 1/min 2200 1400 800 2200 1400 800 2200 1400 800 60 DX pF 40 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 19 2600 AT SC Pb 55 50 qV 2800 75 60 30 150 W 20 80 100 80 W 20 AT S P r 0.02 1/min 3000 3 3 4 4 6 5 8 10 6 7 20 8 9 10 40 60 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 14 20 80 100 200 400 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 3 3 2 3 2 2 3 2 2 -2 -6 -2 -4 -9 -5 -7 -11 -9 -7 -1 2 -10 -2 2 -12 -7 -3 0 -3 -8 0 -3 -9 -4 -4 -11 -8 -8 -5 -9 -9 -6 -8 -11 -8 dB dB dB dB dB dB dB dB dB 9 3 5 6 0 2 3 -3 -3 2 6 7 -2 4 6 -4 -2 2 6 2 -5 6 1 -6 1 0 -7 -6 -5 -8 -6 -5 -7 -7 -6 -6 -7 -10 -12 -7 -9 -11 -6 -6 -8 -12 -14 -18 -11 -13 -17 -7 -8 -11 m/s ISO 5801: 600 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc dB -8 -6 -3 -9 -6 -4 -10 -8 -6 30 500 1000 2000 4000 8000 -4 -5 -3 -5 -6 -4 -4 -7 -5 -5 -4 -2 -6 -5 -3 -6 -5 -3 -4 -3 -6 -5 -4 -6 -5 -4 -4 -5 -8 -10 -5 -7 -10 -4 -5 -6 -10 -13 -16 -9 -11 -16 -6 -7 -11 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 7/7 Dimensions in mm, subject to change. AT S-7/7 5 kg 258 282 232 131 131 288 11 × 16 319 156 47 350 186 208 325 203 28 145 86 201 115.5 115.5 257 19 ø9 ø20 153 117 17 316 340 232 88 225 147 169 172 224 28 6 321 254 272 9 × 12 232 288 324 156 350 172 131 224 28 = 131 186 208 35 337 262 201 115.5 115.5 257 ø9 ø20 153 = 59 19 394 232 6 AT SC-7/7 6 kg = 210 285 = 36 7 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 9/7 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 242 mm 43 0.029 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 2.3 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 7.5 44 0.55 800 95 0.37 600 W W W 2800 19 19 34 2500 17 17 30 2200 15 15 26 2000 13 13 24 1800 12 12 22 1600 11 11 19 1400 9 9 17 1200 8 8 14 1000 7 7 12 800 5 5 10 600 4 4 7 100 dB 0.75 1000 1/min AT AR 65 68 3.0 AT SC 57 % 48 5.5 1.5 kW 1.1 1500 2.2 64 ηr 2500 Pa 2000 AT S Dr z J 56 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 0.25 500 90 0.18 400 0.12 300 85 0.06 200 P r 80 150 0.03 75 70 SX Normal operation area N pF 60 50 300 qV 400 500 pd2 Speed 1/min 2200 1400 800 2200 1400 800 2200 1400 800 1000 1500 0.2 2 3 2 3 ∆LWrel4(A) 8 800 0.1 1.4 v2 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 600 4 0.4 4 6 2000 5 8 10 6 7 20 3000 0.6 8 0.8 9 10 40 60 4000 5000 6000 m³/h 1 14 m³/s 20 80 100 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 400 Pb 65 60 80 LW A7 0.02 DX 100 m/s Measured in installation B according to ISO 5801: 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc dB 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 500 1000 2000 4000 8000 Hz 4 2 2 3 2 1 2 2 2 12 2 -2 10 -1 -6 0 -10 -10 -5 -1 2 -8 -3 2 -15 -8 -4 0 -3 -6 0 -3 -7 -5 -8 -12 -7 -7 -3 -8 -7 -4 -12 -12 -4 dB dB dB dB dB dB dB dB dB 24 11 5 20 7 0 9 -3 -5 3 5 6 0 2 6 -9 -3 -1 5 1 -4 5 0 -4 -1 -5 -10 -5 -4 -1 -5 -5 -3 -9 -10 -2 dB dB dB dB dB dB dB dB dB -7 -4 -4 -8 -5 -4 -10 -5 -5 -6 -6 -8 -6 -6 -7 -5 -6 -6 -9 -11 -15 -8 -9 -13 -6 -7 -9 -15 -18 -22 -12 -15 -20 -9 -11 -14 -5 -2 -2 -5 -4 -3 -7 -3 -4 -4 -4 -6 -5 -5 -6 -3 -4 -5 -7 -9 -13 -7 -8 -11 -5 -6 -8 -13 -16 -20 -11 -14 -18 -8 -10 -14 Belt Driven Centrifugal Fans / AT / Technical Data AT 9/7 Dimensions in mm, subject to change. AT S-9/7 6.6 kg 258 282 232 131 131 288 11 × 16 383 188 120 412 215 262 387 253 30 177 124 255 142.5 142.5 311 19 ø9 ø20 185 119 38 380 340 232 123 300 179 199 172 224 28 6 385 254 272 131 9 × 12 232 288 418 215 262 399 324 35 388 188 172 224 28 172 224 28 = 255 142.5 142.5 311 ø9 ø20 185 = 59 19 394 232 6 AT SC-9/7 8.3 kg 131 = 274 349 = 36 385 262 288 16 × 11 131 232 288 131 418 215 262 50 399 324 ø25 388 188 = ø9 255 142.5 142.5 311 8 185 = 81 7 28 450 232 6 AT AR-9/7 8.3 kg = 274 349 = 36 9 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 9/9 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 242 mm 43 0.034 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 2.9 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2500 Pa ηr 0.75 800 0.55 1/min W W W 2300 15 15 28 2100 14 14 25 1900 13 13 23 1700 11 11 20 1500 10 10 18 1400 9 9 17 1300 9 9 16 1200 8 8 14 1100 7 7 13 1000 7 7 12 900 6 6 11 800 5 5 10 700 5 5 8 600 4 4 7 550 4 4 7 AT AR 100 dB 1.1 1000 41 53 63 7.5 AT SC 1.5 4.0 AT S 53 kW 3.0 59 % 2.2 67 1500 64 2000 95 600 0.37 500 0.25 400 90 0.18 300 0.12 85 200 0.06 80 P r 150 0.03 80 60 500 600 2 v2 pd2 800 2000 Speed 1/min 1900 1200 700 1900 1200 700 1900 1200 700 1500 2 0.4 3 3 ∆LWrel4(A) 10 1000 0.2 qV Duty point SX SX SX qV opt qV opt qV opt DX DX DX Normal operation area N 50 400 70 SX pF 60 65 DX 0.02 LW A7 75 4 4 6 5 8 10 3000 0.6 6 7 20 8 0.8 1 9 10 40 60 4000 5000 6000 8000 10000 m³/h 2 14 m³/s 20 80 100 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 400 m/s Relative sound power level for discharge side LWrel4 at octave centre frequencies fc 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 2 2 2 2 1 1 2 2 2 0 -4 4 -5 -8 2 -9 -13 -5 -5 4 0 -8 3 0 -12 -3 -6 2 -5 -4 2 -4 -5 -3 -10 -11 -8 -5 -3 -7 -6 -4 -12 -11 -7 dB dB dB dB dB dB dB dB dB 9 3 9 3 -2 6 -2 -7 -1 1 8 4 -3 6 3 -8 1 -4 6 -2 -1 4 -2 -2 1 -8 -8 -6 -6 -8 -6 -6 -7 -6 -5 -6 -10 -12 -16 -9 -10 -14 -6 -7 -8 -16 -20 -23 -13 -17 -21 -7 -10 -14 Measured in installation B according to ISO 5801: 600 800 Pa dB -7 -5 -4 -7 -5 -4 -10 -7 -5 Pb 100 500 1000 2000 4000 8000 -5 -3 -1 -5 -4 -3 -9 -8 -4 -4 -3 -2 -5 -4 -3 -6 -4 -3 -5 -5 -7 -6 -5 -6 -4 -4 -4 -8 -10 -14 -8 -9 -12 -4 -5 -7 -14 -18 -22 -12 -16 -20 -6 -9 -14 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 9/9 Dimensions in mm, subject to change. AT S-9/9 7.9 kg 324 348 298 164 164 354 11 × 16 383 188 120 412 215 262 387 253 30 177 124 255 142.5 142.5 311 19 ø9 ø20 185 119 38 380 394 298 123 300 179 199 172 224 28 6 385 320 338 164 9 × 12 298 354 418 215 262 399 324 40 388 188 172 224 28 172 224 28 = 255 142.5 142.5 311 ø9 ø20 185 = 61 19 460 298 6 AT SC-9/9 9.5 kg 164 = 274 349 = 36 385 320 354 16 × 11 164 298 354 164 418 215 262 50 399 324 ø25 388 188 = ø9 255 142.5 142.5 311 8 185 = 81 7 28 500 298 6 AT AR-9/9 9.5 kg = 274 349 = 36 11 Belt Driven Centrifugal Fans / AT / Technical Data AT 10/8 Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 273 mm 48 0.047 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 2.8 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 1500 1.5 1.1 100 dB 1000 W 19 W 19 W 34 2500 17 17 30 2200 15 15 26 1900 13 13 23 1600 11 11 19 1400 9 9 17 1300 9 9 16 1200 8 8 14 1100 7 7 13 1000 7 7 12 900 6 6 11 800 5 5 10 700 5 5 8 600 4 4 7 500 3 3 6 AT AR Pb 2.2 1/min 2800 AT SC 4.0 42 60 % 66 7.5 5.5 AT S 3.0 52 kW 2500 Pa 2000 55 68 65 ηr 0.75 800 0.55 600 95 0.37 500 0.25 400 90 0.18 300 0.12 85 200 0.06 150 P r 80 0.03 500 600 1000 1500 2 3 4 ∆LWrel4(A) Speed 1/min 1900 1200 700 1900 1200 700 1900 1200 700 2000 0.4 3 2 v2 pd2 800 0.2 qV 12 Normal operation area SX 50 400 70 N pF 60 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 65 60 LW 80 A7 75 DX 100 4 6 5 8 10 3000 0.6 6 20 7 8 0.8 9 10 40 60 4000 5000 6000 1 8000 10000 14 80 100 20 m³/s 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 400 m/s 600 800 63 125 250 500 1000 2000 4000 8000 Hz 63 125 250 3 3 2 2 2 2 2 2 2 -9 -7 -3 -12 -10 -6 -12 -12 -11 -8 -3 1 -11 -5 0 -12 -9 -6 -2 -3 -6 -3 -3 -8 -7 -8 -13 -8 -7 -2 -7 -9 -2 -11 -13 -6 dB dB dB dB dB dB dB dB dB 2 2 4 -2 -2 0 -4 -5 -5 0 3 5 -4 0 4 -6 -4 -3 4 1 -3 2 1 -5 -2 -5 -9 -5 -7 -8 -5 -7 -8 -6 -6 -6 -9 -11 -14 -8 -10 -12 -6 -7 -8 -14 -18 -21 -12 -15 -19 -7 -9 -13 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc dB -6 -3 -5 -7 -4 -5 -10 -6 -5 m³/h 2 500 1000 2000 4000 8000 -4 -4 1 -4 -6 0 -8 -9 -4 -3 -1 -3 -4 -2 -4 -6 -4 -3 -3 -5 -6 -4 -6 -6 -3 -4 -5 -7 -9 -12 -7 -8 -11 -4 -5 -6 -12 -16 -20 -10 -14 -18 -6 -8 -13 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 10/8 Dimensions in mm, subject to change. AT S-10/8 8.3 kg 291 315 265 147.5 147.5 321 11 × 16 428 206 132 469 249 289 443 287 198 132 157 284 157 35 340 19 ø9 ø20 203 136 38 425 355 265 135 340 197 227 172 224 28 6 431 287 305 475 249 289 = 434 206 172 224 28 172 224 28 = 265 147.5 147.5 321 9 × 12 455 390 284 157 40 203 340 ø9 ø20 157 60 19 425 265 6 AT SC-10/8 9.8 kg = 330 395 = 36 431 295 321 16 × 11 265 147.5 147.5 321 = 334 206 475 50 249 289 ø25 455 365 ø9 203 = 8 284 157 157 340 79.5 7 28 480 265 6 AT AR-10/8 9.8 kg = 305 395 = 36 13 Belt Driven Centrifugal Fans / AT / Technical Data AT 10/10 Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 273 mm 48 0.055 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 3.5 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 43 66 7.5 kW 1.5 1000 100 dB 1/min W W W 2200 14 14 26 2000 13 13 24 1800 12 12 22 1600 11 11 19 1400 9 9 17 1300 9 9 16 1200 8 8 14 1100 7 7 13 1000 7 7 12 900 6 6 11 800 5 5 10 700 5 5 8 600 4 4 7 AT AR 2.2 5.5 AT SC 1500 3.0 4.0 AT S 57 62 % 68 65 56 ηr 2500 Pa 2000 1.1 800 0.75 600 95 0.55 500 0.37 90 400 0.25 300 0.18 85 0.12 r 200 P 80 A7 150 LW 0.06 70 65 75 Normal operation area N pF 60 50 600 qV v2 800 1000 0.2 2 pd2 3 3 4 14 Speed 1/min 1800 1200 700 1800 1200 700 1800 1200 700 4 6 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 1500 2000 0.4 3000 0.6 5 8 10 6 0.8 7 8 20 4000 5000 6000 9 10 40 60 8000 10000 2 1 14 80 100 200 dB 63 125 250 3 2 2 2 2 2 3 2 2 0 -1 -1 -4 -6 -4 -1 -2 -5 -4 0 3 -8 -3 0 -5 -4 -2 1 0 -4 -1 -2 -6 -3 -4 -9 500 1000 2000 4000 8000 -7 -7 -4 -8 -7 -4 -9 -9 -7 -7 -5 -4 -7 -6 -4 -8 -7 -6 -7 -6 -7 -6 -6 -7 -7 -6 -6 -9 -10 -13 -8 -9 -11 -7 -7 -8 -14 -17 -21 -11 -14 -19 -8 -10 -13 4 30 400 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 15000 m³/h 3 20 Pb SX 80 DX 100 40 m³/s m/s Measured in installation B according to ISO 5801: 600 800 1000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 9 8 5 4 2 1 7 5 0 3 5 7 -2 2 4 1 0 1 5 4 -1 3 1 -3 1 -1 -5 500 1000 2000 4000 8000 -3 -4 -2 -5 -4 -3 -5 -6 -4 -4 -4 -3 -4 -4 -3 -5 -4 -4 -5 -5 -6 -5 -5 -5 -4 -4 -4 -7 -8 -12 -6 -7 -10 -5 -6 -7 -12 -15 -20 -10 -13 -18 -7 -8 -13 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 10/10 Dimensions in mm, subject to change. AT S-10/10 9.3 kg 357 381 331 180.5 180.5 387 11 × 16 428 206 132 469 249 289 443 287 198 132 157 284 157 35 340 19 ø9 ø20 203 136 38 425 420 331 135 340 197 227 172 224 28 6 431 353 371 475 249 289 = 434 206 172 224 28 172 224 28 = 331 180.5 180.5 387 9 × 12 455 390 284 157 40 203 340 ø9 ø20 157 59 19 490 331 6 AT SC-10/10 11 kg = 330 395 = 36 431 361 387 16 × 11 331 180.5 180.5 387 = 434 206 475 50 249 289 ø25 455 365 ø9 203 = 8 284 157 157 340 76.5 7 28 540 331 6 AT AR-10/10 11 kg = 305 395 = 36 15 Belt Driven Centrifugal Fans / AT / Technical Data AT 12/9 Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 322 mm 43 0.097 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 4.4 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. ηr W W W 2200 26 26 33 110 dB 2000 24 24 30 1800 22 22 27 1600 19 19 24 1400 17 17 21 1300 16 16 20 1200 14 14 18 1100 13 13 17 1000 12 12 15 900 11 11 14 800 10 10 12 700 8 8 11 600 7 7 9 500 6 6 8 AT SC AT AR Pb 53 64 68 2.2 1500 1/min AT S 49 11 40 4.0 % kW 3.0 7.5 64 5.5 57 2500 Pa 2000 1.5 1000 105 1.1 800 0.75 100 0.55 600 500 0.37 400 95 0.25 P r 300 0.18 90 0.12 200 150 85 70 65 100 75 80 SX DX Normal operation area 80 LW A7 0.06 N pF 60 50 600 qV 800 2 3 3 4 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 16 1500 Speed 1/min 1800 1200 700 1800 1200 700 1800 1200 700 2000 0.4 2 v2 pd2 1000 0.2 4 6 3000 0.6 5 8 10 6 0.8 7 20 4000 5000 6000 8 40 8000 10000 2 1 9 10 60 14 80 100 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 15000 3 4 30 400 250 500 1000 2000 4000 8000 Hz 63 125 250 2 2 2 1 1 1 2 2 2 1 0 3 0 -1 -4 -10 -10 -6 -2 2 -1 -7 -5 -5 -10 -6 -7 0 -5 -5 -5 -8 -6 -7 -10 -11 -8 -7 -3 -9 -8 -3 -12 -12 -5 dB dB dB dB dB dB dB dB dB 10 7 7 8 6 0 -4 -5 -3 4 6 2 -2 -1 -3 -5 -3 -5 3 -3 -3 -2 -6 -4 -4 -8 -8 -13 -16 -18 -11 -14 -17 -10 -11 -13 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc 125 -9 -10 -13 -8 -9 -11 -7 -8 -10 Measured in installation B 50m/s according to ISO 5801: 600 800 1000 63 -6 -7 -7 -5 -6 -7 -4 -5 -7 m³/s 40 dB -6 -4 -5 -6 -4 -5 -9 -5 -4 m³/h 500 1000 2000 4000 8000 -6 -5 -1 -7 -5 -2 -9 -8 -3 -4 -3 -3 -5 -4 -4 -6 -3 -2 -4 -5 -5 -5 -5 -5 -2 -4 -5 -7 -7 -10 -6 -7 -10 -5 -6 -8 -10 -14 -16 -9 -12 -16 -8 -10 -13 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 12/9 Dimensions in mm, subject to change. AT S-12/9 12.7 kg 335 359 11 × 16 546 38 294 341 521 232 153 309 169.5 169.5 365 494 233 153 182 35 230 161 332 334 182 ø9 ø25 390 8 7 28 491 420 309 161 408 224 266 172 224 28 6 339 365 552 172 224 28 172 224 28 = 309 169.5 169.5 365 11 × 16 500 233 294 341 334 182 45 533 443 ø9 ø25 390 8 230 = 497 182 65 7 28 495 309 6 AT SC-12/9 16 kg = 371 461 = 36 497 339 365 16 × 11 309 169.5 169.5 365 = 500 233 552 60 295 341 ø30 533 443 ø9 230 = 8 334 182 182 390 97.5 7 33 560 309 6 AT AR-12/9 16 kg = 371 461 = 36 17 Belt Driven Centrifugal Fans / AT / Technical Data AT 12/12 Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 322 mm 43 0.118 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 5.2 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. Pa 2000 11 4.0 3.0 2.2 kW 1000 100 dB 1.5 800 1.1 600 0.75 500 95 0.55 1/min W W W 1700 20 20 26 1600 19 19 24 1500 18 18 23 1400 17 17 21 1300 16 16 20 1200 14 14 18 1100 13 13 17 1000 12 12 15 900 11 11 14 800 10 10 12 700 8 8 11 600 7 7 9 500 6 6 8 AT AR 42 7.5 AT SC 64 5.5 AT S 50 58 % 1500 54 67 64 ηr 400 0.37 90 300 0.25 0.18 200 85 0.12 Normal operation area 50 800 N pF 60 1000 1500 qV v2 2 2 pd2 3 3 4 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 18 2000 0.4 Speed 1/min 1400 900 600 1400 900 600 1400 900 600 3000 0.6 4 6 4000 5000 6000 0.8 5 8 10 6 8000 10000 2 1 7 20 8 9 10 40 60 14 63 125 250 2 2 2 2 2 1 2 2 2 -6 -2 5 -3 -2 2 -4 -4 -2 1 5 3 -2 2 0 -4 -2 -3 2 -4 -5 -1 -5 -5 -3 -6 -8 80 100 200 500 1000 2000 4000 8000 -7 -6 -4 -7 -6 -5 -9 -8 -6 -7 -5 -4 -7 -5 -4 -8 -6 -4 -7 -7 -7 -6 -6 -7 -6 -6 -7 -9 -10 -14 -8 -9 -12 -7 -8 -10 4 20 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 15000 3 -14 -18 -21 -13 -17 -20 -10 -12 -14 400 m³/h 5 30 Pb SX 80 75 DX 65 0.06 100 LW 80 70 A7 P r 150 m³/s 40 m/s Measured in installation B according to ISO 5801: 600 800 1000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 2 4 10 4 3 6 2 2 2 6 9 7 3 5 3 1 2 1 6 -1 -2 3 -2 -3 0 -3 -4 500 1000 2000 4000 8000 -5 -4 -3 -5 -4 -3 -5 -4 -3 -6 -4 -3 -5 -4 -3 -5 -4 -3 -5 -5 -5 -5 -5 -6 -4 -4 -5 -7 -8 -12 -7 -8 -11 -6 -7 -8 -13 -17 -20 -11 -16 -20 -9 -11 -15 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 12/12 Dimensions in mm, subject to change. AT S-12/12 15.2 kg 421 445 11 × 16 546 38 294 341 521 232 153 395 212.5 212.5 451 494 233 153 182 35 230 161 332 334 182 ø9 ø25 390 8 7 28 491 510 395 161 408 224 266 172 224 28 6 425 451 = 552 172 224 28 172 224 28 = 395 212.5 212.5 451 11 × 16 500 233 294 341 334 182 45 533 443 ø9 ø25 230 390 8 182 497 67 7 28 585 395 6 AT SC-12/12 18.4 kg = 371 461 = 36 497 425 451 16 × 11 395 212.5 212.5 451 = 500 233 552 60 294 341 ø30 533 443 ø9 230 = 8 334 182 182 390 85 7 33 620 395 6 AT AR-12/12 18.4 kg = 371 461 = 36 19 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 15/11 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 381 mm 51 0.186 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 6.2 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2000 5.5 100 dB 4.0 1500 W 26 W 33 2000 24 24 30 1800 22 22 27 1600 19 19 24 1400 17 17 21 1200 14 14 18 1100 13 13 17 1000 12 12 15 900 11 11 14 800 10 10 12 700 8 8 11 600 7 7 9 500 6 6 8 450 5 5 7 AT AR 58 67 7.5 W 26 AT SC 67 15 1/min 2200 AT S 2500 63 11 58 3000 54 kW % Pa 3500 70 ηr 3.0 95 2.2 1000 1.5 800 90 1.1 600 0.75 500 85 0.55 400 0.37 300 80 0.25 0.12 150 LW 75 A7 P r 200 70 80 1500 0.3 qV pd2 2000 0.4 2 v2 4 20 Speed 1/min 1600 1000 600 1600 1000 600 1600 1000 600 0.8 4 6 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 3000 0.6 3 3 Normal operation area N SX pF 100 5 8 10 4000 5000 6000 8000 10000 1 6 2 7 20 8 40 9 10 60 15000 3 14 80 100 4 20 63 125 250 200 3 3 2 2 2 1 2 2 2 -6 -1 6 -6 -2 4 -7 -6 -3 2 4 0 2 1 -1 -5 -4 -6 0 -3 -2 -2 -3 -3 -5 -7 -7 500 1000 2000 4000 8000 -5 -4 -3 -5 -5 -4 -8 -8 -6 -6 -6 -6 -6 -6 -5 -8 -7 -6 -8 -7 -7 -8 -7 -6 -7 -6 -6 -9 -9 -12 -8 -9 -11 -6 -7 -8 -12 -15 -18 -11 -13 -17 -8 -10 -12 6 400 m³/h 7 40 30 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 20000 5 Pb DX 65 m³/s 50 m/s 600 800 1000 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 3 6 11 1 4 9 -1 0 1 8 8 3 7 5 2 0 0 -3 4 1 1 1 0 -1 -1 -5 -4 500 1000 2000 4000 8000 -2 -2 -1 -3 -3 -4 -5 -5 -4 -4 -4 -4 -5 -6 -4 -5 -5 -4 -6 -5 -5 -7 -5 -5 -5 -4 -4 -7 -7 -10 -6 -7 -9 -5 -6 -7 -10 -13 -17 -9 -12 -16 -7 -9 -12 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 15/11 Dimensions in mm, subject to change. AT S-15/11 17.7 kg 399 423 373 201.5 201.5 429 11 × 16 200 634 38 572 267 342 404 609 380 35 264 197 272 211 ø9 ø25 397 213.5 213.5 453 8 7 28 569 510 373 201 495 258 309 172 224 28 6 403 429 640 172 224 28 172 224 28 = 373 201.5 201.5 429 11 × 16 342 404 45 578 267 = ø9 ø25 264 621 531 8 397 213.5 213.5 453 575 78 7 28 585 373 6 AT SC-15/11 20.9 kg = 449 539 = 36 575 403 429 16 × 11 373 201.5 201.5 429 = 578 267 640 60 342 404 ø30 621 531 ø9 264 = 8 397 213.5 213.5 453 96 7 33 620 373 6 AT AR-15/11 20.9 kg = 449 539 = 36 21 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 15/15 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 381 mm 51 0.233 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 7.5 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2500 Pa 2000 100 dB 800 1.5 1.1 600 95 500 0.75 400 0.55 1/min 1300 W 16 W 16 W 20 1200 14 14 18 1100 13 13 17 1000 12 12 15 900 11 11 14 800 10 10 12 700 8 8 11 600 7 7 9 500 6 6 8 450 5 5 7 400 5 5 6 AT AR 47 58 70 11 AT SC 67 4.0 60 % 3.0 7.5 AT S 1000 54 kW 2.2 5.5 67 ηr 1500 90 0.37 300 0.25 200 85 0.18 150 80 A7 P r 0.12 LW 0.09 70 65 80 N pF 60 50 1500 0.3 qV v2 pd2 2 2000 0.6 0.8 2 3 4 3 4 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 22 Speed 1/min 1100 800 500 1100 800 500 1100 800 500 3000 0.4 6 4000 5000 6000 8000 10000 1 2 5 6 8 10 7 20 8 40 9 10 60 15000 3 14 80 100 63 125 250 200 2 2 1 2 2 2 2 2 2 -4 1 5 -8 -3 1 -4 -1 0 2 2 -1 -1 -1 -3 -2 -2 -6 -3 -2 -1 -5 -3 -2 -6 -5 -4 500 1000 2000 4000 8000 -3 -5 -4 -4 -5 -5 -6 -7 -7 -7 -6 -5 -7 -6 -5 -7 -7 -5 -8 -7 -7 -7 -6 -6 -7 -6 -6 -9 -10 -12 -8 -9 -11 -7 -8 -9 -14 -16 -19 -12 -14 -17 -10 -11 -14 5 20 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 20000 4 6 m³/h 7 m³/s 40 m/s 30 400 Pb SX Normal operation area 75 DX 100 600 800 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 2 6 8 -2 2 4 2 3 3 6 5 2 2 2 0 2 1 -3 0 1 1 -2 0 1 -3 -3 -1 500 1000 2000 4000 8000 -1 -4 -4 -1 -3 -4 -2 -4 -4 -6 -5 -4 -5 -5 -4 -5 -4 -3 -6 -5 -5 -6 -5 -5 -5 -4 -5 -7 -8 -11 -7 -8 -10 -6 -6 -8 -12 -15 -19 -11 -13 -17 -9 -11 -14 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 15/15 Dimensions in mm, subject to change. AT S-15/15 20.6 kg 497 521 471 250.5 250.5 527 11 × 16 200 634 38 572 267 342 404 609 380 40 264 197 272 211 ø9 ø25 397 213.5 213.5 453 8 7 28 569 608 471 201 495 258 309 172 224 28 6 501 527 640 172 224 28 172 224 28 = 471 250.5 250.5 527 11 × 16 342 404 55 578 267 = ø9 ø25 264 621 531 8 397 213.5 213.5 453 575 79 7 28 685 471 6 AT SC-15/15 24.5 kg = 449 539 = 36 575 501 527 16 × 11 471 250.5 250.5 527 = 578 267 640 60 342 404 ø30 621 531 ø9 264 = 8 397 213.5 213.5 453 87 7 33 700 471 6 AT AR-15/15 24.5 kg = 449 539 = 36 23 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 18/13 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 459 mm 48 0.463 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 10.5 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 3.0 1000 2.2 800 100 dB 1.5 600 1.1 500 95 0.75 400 1/min W W W 1300 16 16 22 1200 14 14 20 1100 13 13 19 1000 12 12 17 900 11 11 15 800 10 10 14 700 8 8 12 600 7 7 10 500 6 6 8 400 5 5 7 350 4 4 6 300 4 4 5 AT AR 69 48 71 67 7.5 AT SC 1500 5.5 15 11 AT S kW 4.0 62 % 72 2000 61 ηr 2500 Pa 0.55 300 90 0.37 0.25 200 85 P r 0.18 150 0.12 80 70 SX Normal operation area 50 1500 2000 3000 0.4 qV 0.6 0.8 2 v2 3 4 pd2 3 4 6 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX Speed 1/min 1100 700 400 1100 700 400 1100 700 400 4000 5000 6000 5 8 10 8000 10000 2 1 6 7 20 8 40 9 10 60 15000 3 4 14 80 100 63 125 250 3 2 2 2 2 2 2 2 2 1 7 8 -3 2 6 -8 -3 -2 6 5 -1 1 3 -2 -3 -4 -8 0 -4 -3 1 -5 -3 -7 -9 -4 30000 6 20 8 7 200 400 m³/h 10 m³/s 40 30 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 20000 5 m/s 600 800 1000 Hz 63 125 250 -7 -4 -4 -7 -5 -5 -10 -5 -6 dB dB dB dB dB dB dB dB dB 8 13 12 5 8 10 -2 2 2 11 9 1 6 7 1 2 -1 -4 3 -2 -1 4 -2 -2 -3 -6 -1 -9 -7 -7 -8 -6 -6 -7 -6 -6 -9 -10 -13 -8 -9 -13 -6 -8 -10 -14 -17 -21 -12 -15 -19 -10 -12 -15 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc 500 1000 2000 4000 8000 -6 -7 -5 -6 -7 -5 -5 -7 -5 Pb DX 75 N pF 60 24 65 60 80 LW A7 100 500 1000 2000 4000 8000 -5 -3 -2 -4 -3 -4 -6 -2 -4 -4 -5 -3 -5 -6 -3 -3 -5 -3 -6 -4 -4 -7 -4 -5 -6 -4 -5 -6 -7 -12 -6 -7 -11 -5 -7 -10 -11 -15 -21 -11 -14 -20 -9 -12 -16 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 18/13 Dimensions in mm, subject to change. AT S-18/13 27 kg 456 480 430 230 230 486 11 × 16 288 764 42 687 317 415 478 739 457 40 314 262 340 283 ø9 ø25 471 250.5 250.5 527 8 7 28 684 567 430 278 608 307 376 172 224 28 6 470 506 430 230 230 486 11 × 16 770 415 478 55 751 641 ø9 ø25 693 317 172 224 28 172 224 28 = 8 314 = 690 471 250.5 250.5 527 80 7 28 666 430 6 AT SC-18/13 33 kg = 544 654 = 36 690 470 506 18 × 13 430 230 230 486 = 643 317 770 60 415 478 ø35 751 641 ø9 314 = 10 471 250.5 250.5 527 120 8 38 690 430 6 AT AR-18/13 33 kg = 544 654 = 41 25 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 18/18 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 459 mm 48 0.568 kgm² Performance Curves Please note coloured area! N all types suitable N AT AR only N do not use in this area m r1 15.2 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2500 Pa 2000 44 67 70 2.2 600 1.5 500 100 dB 1.1 400 95 0.55 0.37 90 200 0.25 P r 0.18 85 0.12 13 13 19 1000 12 12 17 900 11 11 15 800 10 10 14 700 8 8 12 600 7 7 10 550 7 7 9 500 6 6 8 450 5 5 8 400 5 5 7 350 4 4 6 75 300 4 4 5 N 50 2000 qV v2 3000 0.6 0.8 2 2 pd2 3 4 ∆LWrel4(A) Speed 1/min 1000 700 400 1000 700 400 1000 700 400 4000 5000 6000 2 4 6 8000 10000 1 5 8 10 6 7 20 15000 3 8 9 10 40 60 4 14 20000 5 6 20 80 100 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 63 125 250 2 2 2 2 2 1 2 2 1 2 6 7 -3 0 2 -5 -5 -6 5 4 1 0 0 -1 -6 -7 -7 -1 -2 -2 -2 -3 -3 -8 -8 -5 500 1000 2000 4000 8000 -5 -4 -3 -5 -4 -4 -7 -6 -6 -6 -6 -5 -6 -6 -5 -6 -7 -5 -8 -8 -7 -7 -7 -6 -7 -6 -6 -10 -10 -13 -8 -9 -13 -6 -7 -9 30000 7 -15 -17 -21 -13 -16 -20 -9 -11 -16 8 400 m³/h 9 10 30 Pb Normal operation area SX 80 LW 70 65 60 60 pF 1100 DX 80 26 20 A7 100 Duty point SX SX SX qV opt qV opt qV opt DX DX DX W 14 0.75 300 150 W 14 AT AR 800 W 1200 AT SC % 3.0 1/min AT S 1000 5.5 55 kW 4.0 15 11 62 7.5 68 1500 57 ηr 40 m³/s m/s Measured in installation B according to ISO 5801: 600 800 1000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 8 12 11 3 5 5 1 0 -2 10 8 4 4 3 2 -2 -3 -4 3 2 0 1 0 -1 -4 -4 -2 500 1000 2000 4000 8000 -2 -2 -2 -2 -3 -3 -4 -3 -4 -4 -4 -4 -5 -5 -3 -4 -5 -4 -7 -6 -6 -6 -5 -5 -5 -5 -4 -8 -9 -12 -7 -8 -12 -5 -6 -9 -13 -16 -21 -12 -15 -21 -8 -11 -17 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 18/18 Dimensions in mm, subject to change. AT S-18/18 32.5 kg 583 607 557 293.5 293.5 613 11 × 16 764 415 478 739 42 687 317 288 40 457 ø9 ø25 314 262 340 283 8 471 250.5 250.5 527 694 557 7 28 684 278 608 307 376 172 224 28 6 597 633 557 293.5 293.5 613 11 × 16 770 415 478 55 751 641 ø9 ø25 693 317 172 224 28 172 224 28 = 8 314 = 690 471 250.5 250.5 527 78 7 28 790 557 6 AT SC-18/18 38.2 kg = 544 654 = 36 690 597 633 18 × 13 557 293.5 293.5 613 = 693 317 770 60 415 478 ø35 751 641 ø9 314 = 10 471 250.5 250.5 527 121 8 38 875 557 6 AT AR-18/18 38.2 kg = 544 654 = 41 27 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 20/15 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 516 mm 42 1.026 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 17.7 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 1500 57 67 70 22 44 kW 7.5 15 68 58 % 2000 11 64 ηr 2500 Pa 5.5 105 dB 4.0 1000 3.0 800 1.5 500 1400 24 1300 22 1200 20 1100 19 1000 17 900 15 800 14 700 12 600 10 500 8 400 7 350 6 300 5 250 4 95 1.1 400 W 100 2.2 600 1/min 0.75 90 300 0.37 85 200 150 0.18 P r 80 0.09 75 65 40 2000 qV pd2 3000 0.6 4 2 28 8000 10000 2 1 3 ∆LWrel4(A) Speed 1/min 1100 700 400 1100 700 400 1100 700 400 4000 5000 6000 0.8 2 v2 Duty point SX SX SX qV opt qV opt qV opt DX DX DX DX SX N pF 50 Normal operation area 70 4 6 5 8 10 6 15000 3 7 20 8 4 9 10 40 60 20000 5 14 63 125 250 80 100 3 3 2 2 2 2 2 2 2 3 6 9 0 2 6 -1 -2 1 4 6 1 1 4 1 -4 -1 -2 3 -1 -1 0 -1 0 -4 -3 0 500 1000 2000 4000 8000 -4 -4 -4 -4 -3 -4 -4 -3 -4 -7 -7 -5 -6 -7 -5 -5 -6 -5 -10 -8 -8 -9 -8 -8 -8 -7 -8 -11 -11 -12 -10 -10 -12 -10 -11 -11 -14 -16 -18 -13 -15 -17 -13 -14 -16 7 8 200 m³/h 9 10 m³/s 30 m/s 20 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 30000 6 400 Pb 60 60 LW A7 80 AT TIC 100 Measured in installation B according to ISO 5801: 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 10 12 13 5 7 10 4 3 4 10 10 4 6 7 3 1 2 1 6 2 2 4 1 2 0 0 2 500 1000 2000 4000 8000 -1 -2 -2 -1 -2 -3 -1 0 -2 -5 -4 -3 -5 -5 -4 -3 -4 -4 -8 -6 -5 -8 -6 -6 -6 -6 -7 -9 -8 -11 -9 -9 -11 -8 -9 -11 -12 -14 -18 -12 -14 -17 -11 -14 -18 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 20/15 830 13 × 18 200 200 502 542 578 833 372 950 = 520 629 65 967 827 ø11 ø35 542 578 369 38 = 10 275 275 622 662 698 96 8 38 770 502 52 Dimensions in mm, subject to change. AT TIC-20/15 71 kg = 632 772 = 58 29 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 20/20 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 516 mm 42 1.175 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 20 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 58 65 68 22 48 59 % 15 54 11 65 ηr 2500 Pa 2000 kW 7.5 1500 105 dB 5.5 1000 100 4.0 3.0 800 2.2 95 600 1.5 500 1.1 400 1/min W 1400 24 1300 22 1200 20 1100 19 1000 17 900 15 800 14 700 12 600 10 500 8 400 7 350 6 300 5 250 4 90 0.75 300 85 0.55 0.37 200 P r 80 150 0.18 75 100 70 3000 4000 5000 6000 1.4 v2 2 3 4 2 ∆LWrel4(A) 30 Speed 1/min 1100 700 400 1100 700 400 1100 700 400 2 1 qV 8000 10000 4 6 5 8 10 15000 3 6 7 20 4 8 5 9 10 40 20000 30000 6 7 14 60 80 100 63 125 250 3 3 2 3 2 2 3 2 2 8 11 12 3 6 10 -2 0 4 2 8 4 -1 7 3 -5 2 0 5 -1 2 5 -1 2 1 -2 0 500 1000 2000 4000 8000 -4 -2 -5 -4 -2 -4 -3 -3 -4 -9 -9 -6 -8 -8 -6 -6 -6 -5 -12 -10 -8 -11 -9 -8 -9 -7 -8 -14 -13 -14 -12 -12 -13 -10 -11 -12 -18 -19 -20 -17 -18 -20 -14 -16 -18 m³/h 9 10 20 14 m³/s 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8 40000 400 Pb SX 40 2000 pd2 Normal operation area N pF 50 DX 65 AT TIC 60 60 Duty point SX SX SX qV opt qV opt qV opt DX DX DX LW A7 80 0.09 m/s Measured in installation B according to ISO 5801: 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 13 17 16 8 12 15 1 5 9 8 13 7 4 12 6 1 7 4 9 2 4 9 2 4 5 2 3 500 1000 2000 4000 8000 -1 0 -4 -1 0 -3 0 0 -2 -8 -8 -4 -6 -7 -5 -4 -4 -4 -11 -8 -7 -10 -8 -7 -7 -6 -7 -12 -11 -13 -11 -11 -12 -8 -10 -12 -16 -18 -21 -15 -17 -21 -14 -15 -19 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 20/20 830 13 × 18 275 275 630 670 706 833 372 950 = 520 629 65 967 827 ø11 ø35 670 706 369 38 = 10 275 275 622 662 698 97 8 38 900 630 52 Dimensions in mm, subject to change. AT TIC-20/20 78 kg = 632 772 = 58 31 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 22/15 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 566 mm 48 1.370 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 20 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 30 70 22 39 2000 52 11 60 15 % 2500 Pa 67 ηr 54 Dr z J 66 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia kW 7.5 1500 110 dB 5.5 4.0 1000 105 3.0 800 2.2 600 100 1.5 500 1.1 400 95 0.75 1/min 1400 W 24 1300 22 1200 20 1100 19 1000 17 900 15 800 14 700 12 600 10 500 8 400 7 300 5 250 4 300 90 0.37 P r 200 80 0.09 70 SX 2000 qV 3000 0.6 0.8 1.4 v2 pd2 32 1 2 2 8000 10000 2 3 4 ∆LWrel4(A) Speed 1/min 1100 700 400 1100 700 400 1100 700 400 4000 5000 6000 N 50 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 75 Normal operation area DX pF 60 A7 65 4 6 5 8 10 15000 3 6 7 20 8 4 5 9 10 40 20000 60 6 63 125 250 3 3 2 2 2 2 2 2 2 2 4 9 0 2 6 -5 -4 2 3 6 1 0 3 0 -4 0 -3 3 -3 -1 1 -3 0 -2 -5 -1 -6 -6 -5 -5 -6 -6 -4 -6 -6 -9 -8 -9 -9 -8 -8 -8 -7 -8 -11 -12 -13 -11 -11 -12 -9 -10 -10 -15 -17 -18 -14 -15 -16 -13 -13 -14 8 200 40000 m³/h m³/s Measured in 9 10 20 80 100 500 1000 2000 4000 8000 -6 -3 -3 -5 -2 -3 -6 -2 -3 7 14 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 30000 30 400 Pb 80 LW 100 85 0.18 AT TIC 150 installation B 40 m/s according to ISO 5801: 600 8001000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 8 11 14 5 8 11 11 2 7 9 11 4 6 8 3 3 4 1 7 0 1 5 0 1 1 -2 2 500 1000 2000 4000 8000 -3 -1 -1 -2 -1 -2 -2 0 -1 -4 -4 -3 -4 -5 -4 -4 -4 -4 -6 -6 -6 -7 -7 -7 -7 -6 -7 -9 -9 -11 -9 -9 -11 -11 -9 -10 -13 -15 -18 -12 -14 -17 -17 -12 -16 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 22/15 905 13 × 18 225 225 514 554 590 908 401 1041 = 573 695 65 1058 918 ø11 ø35 554 590 398 38 = 10 300 300 688 728 764 96 8 38 782 514 52 Dimensions in mm, subject to change. AT TIC-22/15 73 kg = 707 847 = 58 33 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 22/22 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 566 mm 48 1.729 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 26 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. kW 64 50 30 69 67 22 62 15 57 2500 Pa 2000 % ηr 34 11 1500 7.5 110 dB 5.5 1000 4.0 800 105 3.0 600 2.2 500 100 1.5 400 19 1000 17 900 15 800 14 700 12 10 500 9 85 400 7 100 350 6 0.12 80 300 5 70 250 4 A7 Normal operation area 75 50 3000 qV 4000 5000 6000 0.8 pd2 8000 10000 2 1 2 v2 3 4 2 ∆LWrel4(A) Speed 1/min 1100 700 400 1100 700 400 1100 700 400 4 6 N DX 60 65 LW SX 60 15000 3 5 8 10 6 4 7 8 20 40 20000 5 6 9 10 60 30000 7 8 63 125 250 3 3 2 3 3 2 3 3 2 3 6 13 1 4 13 -1 1 8 3 9 6 2 9 6 0 5 -1 5 1 1 5 1 1 3 -4 -2 500 1000 2000 4000 8000 -4 -4 -5 -4 -3 -4 -7 -4 -4 -9 -9 -6 -8 -8 -6 -6 -6 -5 -13 -10 -9 -13 -10 -8 -8 -7 -8 -14 -13 -13 -14 -13 -13 -10 -10 -11 -17 -18 -22 -17 -18 -21 -13 -14 -17 14 20 m³/s 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 60000 m³/h 9 10 14 80 100 40000 Pb P r 0.25 AT TIC 150 pF 20 1100 90 200 34 1200 600 95 0.75 0.55 Duty point SX SX SX qV opt qV opt qV opt DX DX DX W 22 1.1 300 80 1/min 1300 400 m/s Measured in installation B according to ISO 5801: 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 7 12 18 5 10 17 3 6 12 9 14 9 7 13 9 5 10 3 9 4 3 9 4 3 7 0 1 500 1000 2000 4000 8000 -1 -2 -3 -1 -1 -3 -2 -1 -2 -8 -7 -5 -7 -7 -5 -3 -4 -3 -11 -8 -7 -11 -9 -7 -6 -5 -6 -12 -11 -12 -12 -11 -12 -8 -9 -10 -16 -17 -22 -16 -17 -22 -12 -14 -18 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 22/22 905 13 × 18 300 300 692 732 768 908 401 1041 = 573 695 65 1058 918 ø11 ø35 732 768 398 38 = 10 300 300 688 728 764 96 8 38 960 692 52 Dimensions in mm, subject to change. AT TIC-22/22 82.5 kg = 707 847 = 58 35 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 25/20 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 636 mm 56 2.475 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 29 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 47 66 71 40 15 30 66 22 54 kW 57 % ηr 2500 Pa 2000 11 1500 7.5 5.5 1000 105 dB 4.0 800 2.2 500 100 1.5 400 900 19 800 17 700 15 600 13 500 11 400 8 350 7 300 6 250 5 200 4 90 200 85 0.25 80 100 0.12 75 2000 3000 v2 1.4 2 ∆LWrel4(A) Duty Speed point 1/min SX 900 SX 600 SX 300 qV opt 900 qV opt 600 qV opt 300 900 DX DX 600 DX 300 3 4 15000 3 4 6 N 8000 10000 2 2 0.8 1 pd2 70 DX 4000 5000 6000 1 qV LW Normal operation area SX 50 A7 65 5 8 10 4 6 7 20 20000 5 8 40 30000 6 7 9 10 60 63 125 250 4 3 2 2 2 1 3 2 2 5 7 13 2 4 10 -2 -1 4 8 9 4 5 7 3 0 1 -1 2 1 0 1 -1 1 -2 -4 0 500 1000 2000 4000 8000 -4 -4 -3 -5 -2 -3 -6 -3 -3 -7 -7 -6 -5 -7 -6 -4 -5 -5 -11 -10 -8 -10 -9 -9 -8 -8 -8 -14 -12 -13 -13 -12 -14 -10 -11 -12 -15 -17 -21 -16 -17 -21 -14 -15 -18 9 10 14 200 m³/h 14 20 80 100 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8 40000 50000 m³/s Measured in 30 400 Pb 60 60 AT TIC P r 150 pF 21 0.75 0.55 36 1000 95 1.1 300 40 W 23 3.0 600 80 1/min 1100 installation B m/s according to ISO 5801: 600 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 10 14 17 6 9 14 2 5 8 14 13 8 10 11 5 5 5 3 6 4 2 4 2 2 2 0 2 500 1000 2000 4000 8000 -1 -2 -1 -3 -2 -2 -2 0 -1 -5 -5 -4 -4 -6 -5 -2 -4 -4 -9 -8 -6 -9 -8 -7 -6 -6 -7 -11 -10 -11 -11 -11 -13 -9 -10 -12 -13 -15 -22 -15 -17 -23 -13 -15 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 25/20 1010 13 × 18 300 300 664 704 740 1013 441 1175 = 652 797 65 1192 1052 ø11 ø40 704 740 438 38 = 12 350 350 790 830 866 95 8 43 930 664 52 Dimensions in mm, subject to change. AT TIC-25/20 93 kg = 812 952 = 58 37 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 25/25 Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 636 mm 56 2.753 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 33 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. kW 65 30 39 47 57 % 69 65 ηr 2500 Pa 2000 54 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 22 15 11 1500 7.5 1000 5.5 800 105 dB 4.0 3.0 600 100 2.2 500 400 1.5 95 1.1 300 0.75 90 1/min 1000 W 21 900 19 800 17 750 16 700 15 650 14 600 13 550 12 500 11 450 9 400 8 350 7 300 6 250 5 200 4 0.55 P r 200 85 150 0.25 100 80 40 3000 qV 0.8 v2 4000 5000 6000 8000 10000 1 2 2 1.4 0.8 1 pd2 2 ∆LWrel4(A) Duty Speed point 1/min SX 800 SX 500 SX 300 qV opt 800 qV opt 500 qV opt 300 800 DX DX 500 DX 300 3 4 3 4 6 15000 4 5 8 10 6 7 20 20000 30000 5 6 8 9 10 40 7 60 8 63 125 250 80 100 3 2 2 3 2 2 2 2 2 5 8 12 4 7 12 3 4 5 7 8 3 6 7 3 3 2 1 3 -2 0 2 -2 0 -1 -5 -2 -5 -3 -4 -5 -3 -4 -5 -4 -4 -7 -7 -5 -7 -7 -5 -6 -6 -5 -10 -7 -9 -10 -7 -8 -7 -7 -8 -11 -13 -15 -11 -13 -15 -9 -10 -11 -17 -19 -21 -17 -19 -21 -13 -15 -18 m³/h 20 m³/s Measured in 14 500 1000 2000 4000 8000 60000 9 10 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 40000 Pb DX SX N pF 50 38 Normal operation area 75 70 AT TIC 65 60 LW A7 80 0.12 20 200 30 400 600 installation B m/s according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 9 14 17 8 12 16 6 9 10 12 12 6 11 11 7 8 6 4 6 1 1 6 2 2 3 -1 1 500 1000 2000 4000 8000 -3 -3 -3 -2 -2 -2 -2 -1 -2 -7 -6 -3 -5 -6 -3 -4 -4 -3 -8 -6 -7 -8 -6 -7 -6 -5 -7 -10 -11 -14 -10 -11 -14 -8 -10 -12 -16 -19 -23 -16 -19 -23 -13 -15 -21 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 25/25 1010 13 × 18 350 350 794 834 870 1013 441 1175 = 652 797 65 1192 1052 ø11 ø40 834 870 438 38 = 12 350 350 790 830 866 95 8 43 1060 794 52 Dimensions in mm, subject to change. AT TIC-25/25 105 kg = 812 952 = 58 39 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 28/20 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 710 mm 56 3.204 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 31 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 2500 Pa 2000 kW 11 58 72 68 18.5 46 60 % 50 1500 68 ηr 30 7.5 1000 105 dB 4.0 600 100 3.0 500 2.2 400 95 1.5 300 1.1 90 0.75 200 0.55 17 700 15 600 13 550 12 500 10 450 9 400 8 350 7 300 6 250 5 200 4 P r 0.37 80 100 60 Normal operation area 70 LW N DX SX 75 3000 4000 5000 6000 8000 10000 0.9 1 qV 2 2 v2 pd2 2 3 3 ∆LWrel4(A) Duty Speed point 1/min SX 700 SX 450 SX 250 qV opt 700 qV opt 450 qV opt 250 700 DX DX 450 DX 250 4 3 4 6 15000 5 8 10 20000 4 6 5 7 8 20 30000 6 7 9 10 60 40 8 40000 9 10 14 63 125 250 80 100 3 3 2 2 2 2 2 1 1 5 8 8 1 5 8 3 3 0 7 4 5 5 3 3 1 -3 -2 0 2 2 -1 1 2 -5 -4 -2 500 1000 2000 4000 8000 -1 -2 -5 -2 -2 -5 -4 -4 -4 -8 -8 -5 -7 -8 -5 -7 -6 -4 -11 -9 -9 -10 -8 -8 -6 -7 -8 -12 -12 -15 -11 -12 -14 -9 -11 -11 -17 -19 -22 -15 -18 -21 -12 -13 -16 14 m³/h 20 20 400 m³/s m/s 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 60000 Pb 65 AT TIC 80 A7 0.18 pF 800 85 150 40 W 19 5.5 800 50 1/min 900 Measured in installation B according to ISO 5801: 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 11 15 13 6 10 12 6 8 4 12 8 8 10 7 7 6 1 1 4 5 4 2 3 3 -1 -1 0 500 1000 2000 4000 8000 1 0 -3 0 -1 -3 -1 -2 -3 -6 -6 -3 -6 -6 -4 -5 -4 -3 -8 -7 -6 -8 -7 -6 -5 -6 -8 -10 -10 -14 -9 -10 -14 -8 -10 -12 -15 -18 -24 -14 -18 -24 -12 -14 -19 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 28/20 1118 17 × 22 300 300 676 716 752 1121 488 1294 = 718 870 90 1311 1171 ø11 ø40 726 772 485 38 = 12 400 400 863 903 939 134 8 43 1040 676 52 Dimensions in mm, subject to change. AT TIC-28/20 120 kg = 920 1060 = 58 41 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 28/28 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 710 mm 56 3.867 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 35 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. % 54 42 30 48 kW 1500 57 2000 66 69 65 ηr 2500 Pa 18.5 15 11 1000 1/min 900 W 19 800 17 700 15 600 13 550 12 500 11 450 10 400 8 350 7 300 6 250 5 200 4 105 dB 800 7.5 5.5 600 100 4.0 500 3.0 400 95 2.2 300 1.5 90 1.1 200 0.75 70 Normal operation area 50 5000 6000 8000 10000 1.4 qV v2 N 60 2 3 3 4 42 4 4 6 ∆LWrel4(A) Duty Speed point 1/min SX 600 SX 400 SX 250 qV opt 600 qV opt 400 qV opt 250 600 DX DX 400 DX 250 15000 3 2 pd2 DX 75 SX pF 80 5 8 10 20000 5 6 6 7 20 8 40 30000 7 8 9 10 9 10 60 40000 60000 14 14 80 100 20 20 200 63 125 250 3 2 2 2 2 1 2 2 1 9 14 12 7 11 8 7 8 4 10 2 3 8 0 3 5 -1 1 -1 1 2 -1 1 1 -2 -1 -3 500 1000 2000 4000 8000 -3 -3 -4 -2 -3 -4 -5 -5 -4 -9 -7 -6 -8 -6 -5 -7 -5 -5 -11 -9 -9 -9 -8 -9 -7 -7 -8 -13 -14 -15 -12 -12 -14 -10 -10 -11 -19 -18 -19 -16 -18 -19 -13 -14 -17 30 400 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 80000 100000 Pb 80 65 WA 7 0.37 L r P 100 85 0.55 AT TIC 150 m³/h 30 m³/s 40 m/s 600 800 1000 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 13 18 16 11 15 12 11 12 7 14 5 6 11 3 6 9 2 4 2 3 3 2 3 3 2 2 0 500 1000 2000 4000 8000 -1 -1 -2 -1 -1 -2 -2 -3 -2 -7 -5 -4 -6 -5 -4 -5 -4 -3 -9 -8 -8 -8 -7 -8 -6 -6 -7 -12 -13 -15 -11 -12 -14 -9 -10 -12 -18 -19 -22 -16 -19 -22 -13 -16 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 28/28 1118 17 × 22 400 400 870 910 946 1121 488 1294 = 718 870 90 1311 1171 ø11 ø40 920 966 485 38 = 12 400 400 863 903 939 136 8 43 1238 870 52 Dimensions in mm, subject to change. AT TIC-28/28 127 kg = 920 1060 = 58 43 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 30/20 Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 762 mm 64 4.378 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 34 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 15 1500 1/min W 900 19 800 17 700 15 600 13 550 12 500 11 450 10 400 8 350 7 300 6 250 5 200 4 150 3 47 73 69 62 kW 18.5 52 2000 % 30 69 ηr 2500 Pa 59 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 11 7.5 1000 105 dB 5.5 800 4.0 600 100 3.0 500 2.2 400 95 1.5 300 1.1 90 0.75 200 0.55 P r 85 150 80 0.25 100 80 2 15000 3 4 20000 30000 5 6 7 8 9 10 8 40000 60000 80000 100000 m³/h 20 9 10 Measured in 30 m³/s installation B according to 2 2 3 4 ∆LWrel4(A) Duty Speed point 1/min SX 600 SX 400 SX 250 qV opt 600 qV opt 400 qV opt 250 600 DX DX 400 DX 250 DX 8000 10000 1 1 pd2 44 N 4000 5000 6000 1.4 v2 70 Pb 65 Normal operation area SX pF 40 3000 qV A7 LW 60 50 AT TIC 60 75 0.12 4 6 5 8 10 6 7 20 40 60 14 20 80 100 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 63 125 250 3 3 2 2 2 2 2 2 1 6 9 11 7 8 9 8 8 2 7 6 7 6 4 5 3 -2 -1 2 3 2 1 2 2 -3 -3 -2 500 1000 2000 4000 8000 -2 -3 -6 -2 -3 -5 -4 -4 -5 -10 -9 -6 -8 -8 -6 -7 -6 -5 -11 -9 -8 -10 -9 -8 -7 -7 -8 -12 -13 -15 -12 -12 -13 -10 -10 -10 -18 -20 -21 -16 -18 -20 -12 -13 -15 30 400 50 m/s ISO 5801: 40 600 800 1000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 12 15 16 12 14 13 13 13 7 13 10 10 11 9 8 8 3 3 6 5 4 5 4 3 2 0 1 500 1000 2000 4000 8000 0 -1 -4 -1 -2 -4 -2 -2 -3 -8 -6 -4 -7 -7 -4 -5 -4 -3 -9 -7 -6 -9 -7 -6 -5 -6 -7 -10 -11 -14 -10 -11 -13 -9 -10 -11 -16 -20 -23 -16 -19 -23 -12 -14 -18 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 30/20 1196 17 × 22 300 300 676 716 752 1200 520 1393 = 776 936 90 1410 1270 ø11 ø40 726 772 516 38 = 12 425 425 929 969 1005 134 8 43 1040 676 52 Dimensions in mm, subject to change. AT TIC-30/20 131 kg = 998 1138 = 58 45 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). AT 30/28 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 762 mm 64 5.07 kgm² Performance Curves Please note coloured area! N all types suitable N do not use in this area m r1 40 kg 1.2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 1/min 58 68 15 1500 W 45 71 68 30 61 51 kW 18.5 % ηr 2500 Pa 2000 11 110 dB 900 19 800 17 700 15 600 13 550 12 500 11 450 9 400 8 350 7 300 6 250 5 200 4 150 3 7.5 1000 5.5 800 105 4.0 600 3.0 500 100 2.2 400 95 1.5 300 1.1 90 0.75 200 0.55 150 85 P r 0.37 80 100 65 60 70 4000 5000 6000 2 1 v2 3 3 2 4 2 ∆LWrel4(A) 46 DX 15000 20000 4 5 30000 6 7 8 40000 60000 9 10 80000 100000 m³/h 20 Measured in 30 m³/s installation B according to 1.4 0.8 1 pd2 Duty Speed point 1/min SX 600 SX 400 SX 250 qV opt 600 qV opt 400 qV opt 250 600 DX DX 400 DX 250 8000 10000 N 40 3000 qV Normal operation area SX pF 50 Pb 75 60 AT TIC LW A7 0.18 80 4 6 5 6 8 10 7 20 8 40 9 10 60 14 80 100 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 63 125 250 3 2 2 3 2 2 3 2 2 9 14 14 8 12 13 9 11 8 11 5 2 10 4 2 8 2 1 -2 -2 0 -2 -1 0 -2 -2 -2 500 1000 2000 4000 8000 -5 -3 -2 -4 -3 -3 -5 -4 -3 -7 -6 -6 -7 -6 -6 -7 -6 -5 -11 -9 -9 -10 -9 -9 -8 -8 -8 -13 -13 -15 -12 -12 -14 -11 -10 -10 -19 -19 -21 -17 -18 -20 -13 -14 -17 20 200 m/s ISO 5801: 30 400 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 14 18 18 12 16 17 13 15 12 15 9 5 14 8 5 12 5 4 1 0 1 1 1 2 2 2 1 500 1000 2000 4000 8000 -4 -1 0 -2 -1 -1 -2 -2 -1 -5 -5 -5 -5 -5 -5 -5 -4 -4 -9 -8 -8 -9 -7 -7 -7 -6 -7 -12 -12 -15 -11 -11 -14 -9 -10 -11 -18 -20 -24 -16 -19 -23 -13 -15 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / AT / Technical Data AT 30/28 1196 17 × 22 400 400 870 910 946 1200 520 1393 = 776 936 90 1410 1270 ø11 ø40 920 966 516 38 = 12 425 425 929 969 1005 136 8 43 1238 870 52 Dimensions in mm, subject to change. AT TIC-30/28 138 kg = 998 1138 = 58 47 Belt Driven Centrifugal Fans / AT / Twin fan arrangement AT G2L E A1 G1 G X1 172 S X2 X4 B B1 C F Q E A R K X3 V AT G2L 07/07-18/18 AT G2L 12/09-18/18 t ød ø9 B2 t1 t1 AT G2L 07/07-10/10 6 F2 P L ød w w z E2 z A2 C2 E2 AT G2L 07/07-18/18 A B 7/7 316 325 9/7 380 387 9/9 380 387 10/8 425 443 10/10 425 443 12/09 491 521 12/12 491 521 15/11 569 609 15/15 569 609 18/13 684 739 18/18 684 739 C 208 262 262 289 289 341 341 404 404 478 478 E 232 232 298 265 331 309 395 373 471 430 557 F 186 215 215 249 249 294 294 342 342 415 415 G 153 185 185 203 203 230 230 264 264 314 314 H 184 184 244 214 264 244 324 294 384 343 458 L 698 698 890 794 976 912 1164 1190 1376 1253 1622 M 808 808 1000 904 1086 1082 1334 1260 1546 1423 1792 P 258 258 324 291 357 335 425 399 497 456 583 Q 203 253 253 287 287 332 332 380 380 457 457 R 169 199 199 227 227 266 266 309 309 376 376 7/7 9/7 9/9 10/8 10/10 12/09 12/12 15/11 15/15 18/13 18/18 S 145 177 177 198 198 232 232 272 272 340 340 V 147 179 179 197 197 224 224 258 258 307 307 K 225 300 300 340 340 408 408 495 495 608 608 X1 117 119 119 136 136 161 161 197 197 262 262 X2 86 124 124 132 132 153 153 211 211 283 283 X3 88 123 123 135 135 161 161 201 201 278 278 X4 47 120 120 132 132 153 153 200 200 288 288 U×S 11×16 11×16 11×16 11×16 11×16 11×16 11×16 11×16 11×16 11×16 11×16 t – – – – – 8 8 8 8 8 8 t1 19 19 19 19 19 28 28 28 28 28 28 w 60 60 60 60 60 90 90 90 90 90 90 z 65 65 65 73 73 105 105 105 105 110 110 7/7 9/7 9/9 10/8 10/10 12/09 12/12 15/11 15/15 18/13 18/18 A1 319 383 383 428 428 494 494 572 572 687 687 B1 350 412 412 469 469 546 546 634 634 764 764 G1 156 188 188 206 206 233 233 267 267 317 317 A2 232 232 298 265 331 309 395 373 471 430 557 B2 201 255 255 284 284 334 334 397 397 471 471 C2 288 288 354 321 387 365 451 429 527 486 316 D2 257 311 311 340 340 390 390 453 453 527 527 E2 131.0 131.0 164.0 147.5 180.5 169.5 212.5 201.5 250.5 230.0 293.5 F2 115.5 142.5 142.5 157.0 157.0 182.0 182.0 213.5 213.5 250.5 250.5 48 28 224 F2 P U×S D2 M H 17 Dimensions in mm, subject to change. AT G2L 07/07-18/18 d 20 20 20 20 20 25 25 25 25 25 25 Belt Driven Centrifugal Fans / AT / Twin fan arrangement AT SC2 Dimensions in mm, subject to change. AT SC2 7/7-18/18 E H K G H1 G1 S M Q E B X2 B1 C F = R X1 A = AT SC2 7/7-18/18 t1 AT SC2 7/7-18/18 t ø9 B2 F2 ød w E2 z AT SC2 7/7-18/18 A 7/7 285 9/7 349 9/9 349 10/8 395 10/10 395 12/9 461 12/12 461 15/11 539 15/15 539 18/13 654 18/18 654 28 F2 = P 224 D2 = V L P 172 U×S A2 C2 B 337 399 399 455 455 533 533 621 621 751 751 C 208 262 262 289 289 341 341 404 404 477 477 E 232 232 298 265 331 309 395 373 471 430 557 F 186 215 215 249 249 294 294 342 342 415 415 G 153 185 185 203 203 230 230 264 264 314 314 H 321 385 385 431 431 497 497 575 575 690 690 L 686 684 872 773 957 913 1165 1094 1384 1262 1647 M 843 843 1033 950 1134 1066 1316 1243 1537 1425 1805 P 254 254 320 287 353 339 425 403 501 470 597 Q 182 180 236 203 255 239 319 292 386 326 457 z 75.5 76.5 77.5 85.5 85.5 79.5 78.5 77.5 79.5 84.5 82.0 d 20 20 20 20 20 25 25 25 25 25 25 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 S 6 6 6 6 6 6 6 6 6 6 6 V 160 158 214 181 233 209 289 262 356 286 417 K 78.5 79.5 80.5 88.5 88.5 76.5 75.5 74.5 76.5 81.5 79.0 X1 210 274 274 330 330 371 371 449 449 544 544 X2 262 324 324 390 390 443 443 531 531 641 641 U×S 9×12 9×12 9×12 9×12 9×12 11×16 11×16 11×16 11×16 11×16 11×16 t 6 6 6 6 6 8 8 8 8 8 8 t1 23 23 23 23 23 28 28 28 28 28 28 w 60 60 60 60 60 65 65 65 65 65 65 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 B1 350 418 418 475 475 552 552 640 640 770 770 G1 156 188 188 206 206 233 233 267 267 317 317 H1 324 388 388 434 434 500 500 578 578 693 693 A2 232 232 298 265 331 309 395 373 471 430 557 B2 201 255 255 284 284 334 334 397 397 471 471 C2 288 288 354 321 387 365 451 429 527 486 613 D2 257 311 311 340 340 390 390 453 453 527 527 E2 131.0 131.0 164.0 147.5 180.5 169.5 212.5 201.5 250.5 230.0 293.5 F2 115.5 142.5 142.5 157.0 157.0 182.0 182.0 213.5 213.5 250.5 250.5 E2 R 20 20 20 20 20 28 28 28 28 38 38 49 Belt Driven Centrifugal Fans / AT / Twin fan arrangement AT G2C Dimensions in mm, subject to change. AT G2C 09/07-18/18 E H K G S M Q E H1 G1 B X2 B1 C F = R = X1 A V AT G2C 09/07-18/18 t1 AT G2C 09/07-18/18 t = F2 ø9 B2 F2 ød w E2 A2 E2 C2 z AT G2C 09/07-18/18 A B 9/7 347 423 9/9 347 423 10/8 393 479 10/10 393 479 12/09 457 580 12/12 457 580 15/11 533 667 15/15 533 667 18/13 646 797 18/18 646 797 C 262 262 289 289 341 341 404 404 478 478 E 232 298 265 331 309 395 373 471 430 557 F 215 215 249 249 294 294 342 342 415 415 G 185 185 203 203 230 230 264 264 314 314 H 385 385 431 431 497 497 575 575 690 690 L 704 896 800 982 938 1190 1116 1402 1299 1668 M 864 1056 960 1142 1158 1410 1336 1622 1519 1888 P 678 870 774 956 902 1154 1080 1366 1253 1622 Q 184 244 214 264 244 324 294 384 343 458 9/7 9/9 10/8 10/10 12/09 12/12 15/11 15/15 18/13 18/18 S 31 31 31 31 52 52 52 52 52 52 V 38 38 38 38 40 40 42 42 44 44 K 80 80 80 80 110 110 110 110 110 110 X1 257 257 289 289 327 327 403 403 506 506 X2 333 333 375 375 450 450 537 537 657 657 t 8 8 8 8 10 10 10 10 12 12 t1 33 33 33 33 38 38 38 38 43 43 w 55 55 55 55 90 90 90 90 90 90 z 60 60 60 60 91 91 91 91 97 97 d 30 30 30 30 35 35 35 35 40 40 u×s 13x18 13x18 13x18 13x18 13x18 13x18 13x18 13x18 17x22 17x22 9/7 9/9 10/8 10/10 12/09 12/12 15/11 15/15 18/13 18/18 B1 418 418 475 475 553 553 640 640 770 770 G1 188 188 206 206 233 233 267 267 317 317 H1 388 388 434 434 500 500 578 578 693 693 A2 232 298 265 331 309 395 373 471 430 557 B2 255 255 284 284 334 334 397 397 471 471 C2 288 354 321 387 365 451 429 527 486 613 D2 311 311 340 340 390 390 453 453 527 527 E2 131.0 164.0 147.5 180.5 169.5 212.5 201.5 250.5 230.0 293.5 F2 142.5 142.5 157.0 157.0 182.0 182.0 213.5 213.5 250.5 250.5 50 D2 U×S P L 224 = 172 R 28 28 28 28 38 38 38 38 48 48 28 Belt Driven Centrifugal Fans / AT / Twin fan arrangement AT G2C Dimensions in mm, subject to change. AT G2C 20/15-30/28 E H K G S M Q E H1 G1 B X2 B1 C F = R = 38 = X1 A V AT G2C 20/15-30/28 t1 AT G2C 20/15-30/28 t = ø11 H2 B2 F2 D2 U×S P L H2 ød w G2 z AT G2C 20/15-30/28 A B 20/15 772 967 20/20 772 967 22/15 847 1058 22/22 847 1058 25/20 952 1192 25/25 952 1192 28/20 1060 1311 28/28 1060 1311 30/20 1138 1410 30/28 1138 1410 A2 E2 C2 G2 C 629 629 695 695 797 797 870 870 936 936 E 502 630 514 692 664 794 676 870 676 870 F 520 520 573 573 652 652 718 718 776 776 G 369 369 398 398 438 438 485 485 516 516 H 830 830 905 905 1010 1010 1118 1118 1196 1196 L 1470 1866 1470 2050 1934 2240 1958 2550 1958 2550 M 1730 2126 1730 2310 2194 2500 2220 2810 2220 2810 P 1424 1820 1424 2004 1888 2194 1912 2504 1912 2504 Q 370 510 346 570 510 556 510 714 510 714 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 S 52 52 52 52 52 52 52 52 52 52 V 58 58 58 58 58 58 58 58 58 58 K 130 130 130 130 130 130 131 130 131 130 X1 632 632 707 707 812 812 920 920 998 998 X2 827 827 918 918 1052 1052 1171 1171 1270 1270 U×S 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 t 12 12 12 12 12 12 12 12 12 12 t1 43 43 43 43 43 43 43 43 43 43 w 90 90 90 90 90 90 90 90 90 90 z 117 117 117 117 117 117 118 117 118 117 d 40 40 40 40 40 40 40 40 40 40 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 B1 950 950 1041 1041 1175 1175 1293 1293 1393 1393 G1 372 372 401 401 441 441 488 488 520 520 H1 833 833 908 908 1013 1013 1121 1121 1200 1200 A2 502 630 514 692 664 794 676 870 676 870 B2 622 622 688 688 790 790 863 863 929 929 C2 578 706 590 768 740 870 752 946 752 946 D2 698 698 764 764 866 866 939 939 1005 1005 E2 542 670 554 732 704 834 716 910 716 910 F2 662 662 728 728 830 830 903 903 969 969 G2 200 275 225 300 300 350 300 400 300 400 H2 275 275 300 300 350 350 400 400 425 425 R 48 48 48 48 48 48 48 48 48 48 51 Belt Driven Centrifugal Fans / AT / Twin fan arrangement AT G2C-C2 Dimensions in mm, subject to change. AT G2C-C2 20/15-30/28 E H K G S M Q E H1 G1 B X2 C B1 F = R = 38 = X1 A V AT G2C-C2 20/15-30/28 ø11 t1 AT G2C-C2 20/15-30/28 t = H2 B2 F2 D2 U×S P L H2 ød w G2 z AT G2C-C2 20/15-30/28 A B 20/15 772 967 20/20 772 967 22/15 847 1058 22/22 847 1058 25/20 952 1192 25/25 952 1192 28/20 1060 1311 28/28 1060 1311 30/20 1138 1410 30/28 1138 1410 A2 E2 C2 C 629 629 695 695 797 797 870 870 936 936 E 502 630 514 692 664 794 676 870 676 870 F 520 520 573 573 652 652 718 718 776 776 G 369 369 398 398 438 438 485 485 516 516 H 830 830 905 905 1010 1010 1118 1118 1196 1196 L 1470 1866 1470 2050 1934 2240 1958 2550 1958 2550 M 1816 2212 1816 2396 2280 2586 2304 2896 2304 2896 P 1424 1820 1424 2004 1888 2194 1912 2504 1912 2504 Q 370 510 346 570 510 556 510 714 510 714 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 S 52 52 52 52 52 52 52 52 52 52 V 58 58 58 58 58 58 58 58 58 58 K 173 173 173 173 173 173 173 173 173 173 X1 632 632 707 707 812 812 920 920 998 998 X2 827 827 918 918 1052 1052 1171 1171 1270 1270 U×S 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 17×22 t 14 14 14 14 14 14 14 14 14 14 t1 48 48 48 48 48 48 48 48 48 48 w 90 90 90 90 90 90 90 90 90 90 z 130 130 130 130 130 130 130 130 130 130 d 45 45 45 45 45 45 45 45 45 45 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 B1 950 950 1041 1041 1175 1175 1293 1293 1393 1393 G1 372 372 401 401 441 441 488 488 520 520 H1 833 833 908 908 1013 1013 1121 1121 1200 1200 A2 502 630 514 692 664 794 676 870 676 870 B2 622 622 688 688 790 790 863 863 929 929 C2 578 706 590 768 740 870 752 946 752 946 D2 698 698 764 764 866 866 939 939 1005 1005 E2 542 670 554 732 704 834 716 910 716 910 F2 662 662 728 728 830 830 903 903 969 969 G2 200 275 225 300 300 350 300 400 300 400 H2 275 275 300 300 350 350 400 400 425 425 52 G2 R 48 48 48 48 48 48 48 48 48 48 Belt Driven Centrifugal Fans / Notes Notes Notes 53 Belt Driven Centrifugal Fans / AT / Specifications AT S 7/7-18/18 Specifications High performance centrifugal fan AT S Double width double inlet (DWDI) belt driven fan, with forward curved blades. Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming. Straight cut off plate at fan outlet. Impeller with forward curved blades of galvanized steel EN 10142, statically and dynamically balanced to grade G4, according to UNI ISO 1940. Light construction, without side frames. Single row, deep groove, self-aligning ball bearings, lubricated and sealed for life, with eccentric collar locking. Bearings are mounted inside conductive rubber vibration absorbers on bearing supporting spiders. The mounting feet, which allow the fan to be installed in the 4 positions 0, 90, 180 and 270, as well as the outlet flange, are available on request. For sizes from 7/7 to 10/10, in addition to the standard construction version with flats on shaft ends (“type 1”), it is also available a version with keyways (“type 2”). Shaft ends of larger sizes are only of “Type 2”. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 54 Belt Driven Centrifugal Fans / AT / Specifications AT SC 7/7-18/18 AT C 7/7-18/18 Specifications High performance centrifugal fan AT SC and AT C Double width double inlet (DWDI) belt driven fan, with forward curved blades. Lap-jointed scroll of galvanized steel EN 10142 assembled through roller-lock seaming. Straight cut off plate at fan outlet. Impeller with forward curved blades of galvanized steel EN 10142, statically and dynamically balanced to grade G4, according to UNI ISO 1940. Construction with two side frames, made of cold-formed galvanized steel angular sections welded to the side plates, for a better strength and stiffness of the fan structure. Single row, deep groove, self-aligning ball bearings, lubricated and sealed for life, with eccentric collar locking. Bearings are mounted inside conductive rubber vibration absorbers on bearing supporting spiders. It can be easily installed in four different positions. Discharge flange on request. Where an even better mechanical strength is required, e.g. when the fan itself is used as a stiffening element of the base frame, a further reinforced version is available. It is identified by the letter C. This version is available in the same sizes as the SC version, with the same dimensions and the same performance limits. With the addition of three steel bars, welded between three corners of the side frames, the frames of these fans are joined to form a closed, box-like supporting structure. For sizes from 7/7 to 10/10, in addition to the standard construction version with flats on shaft ends (“type 1”), it is also available a version with keyways (“type 2”). Shaft ends of larger sizes are only of “Type 2”. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 55 Belt Driven Centrifugal Fans / AT / Specifications AT AR 9/7-18/18 Specifications High performance centrifugal fan AT AR Double width double inlet (DWDI) belt driven fan, with forward curved blades. Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming. Straight cut off plate at fan outlet. Impeller with forward curved blades of galvanized steel EN 10142, statically and dynamically balanced to grade G4, according to UNI ISO 1940. For applications requiring even higher installed power, or where there is a requirement for re-lubricatable bearings, the AR version is the correct solution. The reinforced side-frames are made of galvanized steel sections, welded to the sides of the scroll and joined together in three corners. Single row, deep groove, self-aligning ball bearings, re-lubricatable and reinforced, with eccentric collar locking. Bearings are mounted inside a single-piece cast iron pillow block. It can be easily installed in four different positions. Discharge flange on request. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 56 Belt Driven Centrifugal Fans / AT / Specifications AT TIC 20/15-30/28 Specifications High performance centrifugal fan AT TIC Double width double inlet (DWDI) belt driven fan, with forward curved blades. Lap-jointed scroll of galvanized steel EN 10142 assembled with Pittsburgh lock seam. Straight cut off plate at fan outlet. Impeller with forward curved blades of galvanized steel EN 10142, statically and dynamically balanced with grade G4, according to UNI ISO 1940. Mechanically designed in a way very similar to the previous version, apart for the larger sized impeller and a fourth traverse, so the frames on the sides are joined together in all the four corners. Single row, deep groove, self-aligning ball bearings, re-lubricatable and reinforced, with eccentric collar locking. Bearings are mounted inside a single-piece cast iron pillow block. It can be easily installed in four different positions. Discharge flange on request. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Options may be available only for orders of a minimum quantity, to be previously agreed • Matching flange • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 57 Belt Driven Centrifugal Fans / AT / Specifications AT G2L 7/7-18/18 Specifications High performance centrifugal twin fan AT G2L (size from 7/7 to 18/18) Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming. This twin version is made with two S version single fans, connected through three U-section spars and is fitted with two double-inlet impellers mounted on a common shaft, supported by three bearings. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 58 Belt Driven Centrifugal Fans / AT / Specifications AT SC2 7/7-18/18 Specifications High performance centrifugal twin fan AT-SC2 (size from 7/7 to 18/18) Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming. Twin version, made of two SC version fans, joined by three L-section spars, welded in the corners of the side frames. Two double-inlet impellers are mounted on a single shaft, supported by three bearings on rubber shock absorbers and inlet-mounted supporting spiders. The SC2 fans have the same characteristics of the G2L versions but with the additional stiffness provided by the welded frame. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 59 Belt Driven Centrifugal Fans / AT / Specifications AT G2C 9/7-30/28 AT G2C-C2 20/15-30/28 Specifications High performance centrifugal twin fan AT-G2C (size from 9/7 to 30/28) Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming (size up to 18/18) or with Pittsburgh lock seam (for sizes larger than 18/18). Inside a common supporting frame, made of galvanized steel sections, two doubleinlet fans are mounted side-by-side. They are joined by a single shaft, supported at the ends by two pillow-block bearings, bolted on the side frames. This particular design doesn’t need a third bearing between the impellers, and weight is kept low thanks to the use of large section, hollow shafts on the larger sizes. High performance centrifugal twin fan AT-G2C-C2 (size from 20/15 to 30/28) Lap-jointed scroll of galvanized steel EN 10142 assembled with Pittsburgh lock seam. The G2C-C2 fan is a reinforced twin unit, suitable to achieve higher speed and power levels than the G2C. Mechanical design is similar to that of the G2C fans, but hollow shafts with larger diameter (45 mm) journals and heavy duty split-block bearings make them stronger. The G2C-C2 fans retain the other characteristics of the G2C fans. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 60 Belt Driven Centrifugal Fans / AT / Specifications AT SC2 7/7-18/18 Specifications High performance centrifugal tripple fan AT G3C (size from 12/9 to 30/28) Lap-jointed scroll of galvanized steel EN 10142 assembled with roller-lock seaming (size up to 18/18) or with Pittsburgh lock seam (for sizes larger than 18/18) The G3C is a triple fan: three identical double-inlet units are mounted inside a common frame of steel sections. The single, common shaft is supported by just two pillow-block bearings, bolted on the end frames. This special version is particularly suited when a large airflow must be distributed on a wide surface, or when a fan of particularly limited height can be useful. Other advantages of this design are the use of a single motor, operation without bearings installed between the impellers, and low weight thanks to the use of hollow shafts. Using a common shaft, without intermediate bearings and couplings, provides also a reliable and smooth operation, with limited operating noise. High performance centrifugal tripple fan AT G3C-C2 (size from 20/15 to 30/28) Lap-jointed scroll of galvanized steel EN 10142 assembled with Pittsburgh lock seam. Of similar construction to the G3C version, but employs larger diameter hollow shafts, with larger diameter journals and heavy-duty bearings on split-type pillow blocks. These improvements allow operation at higher speed and power levels. The G3C-C2 fans keep unchanged all the other characteristics of the G3C fans. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • Mounting feet Motor brackets (Pick-A-Back) Discharge flange Discharge flex with flexible sleeve Inlet guards Discharge guard Shaft guard for free shaft end Matching flange Options may be available only for orders of a minimum quantity, to be previously agreed • Inspection door • Drain plug • Single or double thickness powder coating • Shaft made of stainless steel • Nuts and bolts and fastening elements made of stainless steel • Aluminium inlet cone • Copper inlet cone 61 Fittings / Accessories [1] Mounting feet [2] Discharge flange [3] Discharge flex [4] Inlet guard [5] Discharge guard [6] Shaft guard [7] Mounting flange [8] Inspection door [9] Drain plug A extended corrosion protection A ATEX-Execution (RZR) A Impellerblades continuosly welded (RZR) A Casing continuosly welden-inside (RZR) A Casing continuosly welden- inside/outside (RZR) A Split casing (RZR 13/19) A Shaft from stainless steel A Nuts and bolts from stainless steel A Thread for impuls sensor fitting A Volumeter (RDH / RZR) A Copper inlet cone A Aluminium inlet cone (ADH / AT / RDH) A hot dip galvanised side frame (ADH / RDH) A relubricatable bearings (relubrication during operation, RZR) Fan set (ADH / AT / RDH on request) [10] Base frame [11] Pick-a-Back [12] Belt drive [13] Drive guard A Belt guard split horizontally A Access door on belt guard A Opening on belt guard for speed measuring device [14] Drive motor [15] Anti-vibration mounts 62 Gebhardt fan systems – the "completely carefree" package for installation fans with belt drive Fan systems with components tailored for each other, precisely assembled and adjusted, individually tested, delivered quickly and on time, allow for problem-free processing and ensure long and reliable operation. Size has its price so we build as small as possible Where required, we deliver our fan systems with safety equipment complying with DIN EN ISO 13857 for safe operation! A Optimised base frame lengths, tailored to the casing position and motor size and small system construction heights save valuable space in the air conditioning unit A Various casing and drive positions allow for individual adjustment to the most diverse applications A Optimised flat belt drives allow for efficient operation with a high level of convenience e.g. Belt guard A also as segmented design A also with inspection hole A also with rotation speed measurement opening. Fan set diversity Version Description Pick-A-Back for sizes 0200/-0355 Pick-A-Back for sizes 0400/-1000 Compact base frame Integrated compact base frame for sizes up to 0500. Base Frame, CC-profile Base frames made from CC-profiles with length optimation. Base Frame, U-profile Heavy duty base frame made from U-profiles, welded and painted, from size 0800 upward. Figure 63 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Drain Plug If the fan is installed outside, or if conveying a medium containing humidty, condensation of water may accumulate inside the fan scroll. For extraction of this water a condense water drain has to be installed at the lowest point of the scroll. The drain will be provided with a thread for connecting it to a piping. At order please indicate the required casing position. Connecting thread / hole A ADH / RDH = female thread R 1/8" A AT = drain hole A RZR 0200/-1000 = male thread R 1/2" A RZR 1120/-1600 = male thread R 1" Dimensions R R Inspection Door For the purposes of maintenance and cleaning there is an opening, which can be securely closed by means of an access door, in the fan casing. As it can only be opened with a tool, the access door complies with safety and accident prevention regulations. Additional securing with locking bars can be supplied on request. The site and orientation of the inspection opening depends on the casing position. The position should be specified when ordering according to the following diagram: e.g. Access door, Pos. 2. Inspection Door Positions Pos.1 Pos.2 Pos.3 Pos.1 Pos.1 Pos.2 Pos.2 Pos.4 Pos.3 Pos.3 ADH / RDH RZR 0200/-1000 RZR 1120 RZR 1250/-1600 Dimensions in mm, subject to change. ADH ..0160/-0180 0200/-0280 0315/-0560 0630/-1000 – 64 RZR ..- RDH ..100 × 230 240 × 240 360 × 360 500 × 500 500 × 500 0180 0200/-0280 0315/-0560 0630/-1000 1120/-1400 100 × 230 240 × 240 360 × 360 500 × 500 500 × 500 – 0200 0225/-0315 0355/-1000 1120/-1600 160 × 160 210 × 210 310 × 310 500 × 500 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Corrosion Protection Systems Nicotra Gebhardt fans are treated with high quality corrosion protection as standard. Under extreme operating conditions, however, additional corrosion protection is advisable. ADH / AT / RDH Extended corrosion protection for series ADH, AT and RDH only available on request. RZR Depending on the use to which the fan is to be put and the degree of exposure to corrosion, we offer various anti-corrosion protection measures. Corrosion protection - Class S40 Degreasing, ironphosphating A Powder coating Layer thickness ≥40 μm, Colour RAL 7039 A Wet lacquering Layer thickness ≥40 μm (primer + lacquer finish), Colour RAL 7039 Corrosion protection - Class K90 Degreasing, ironphosphating A Powder coating Layer thickness ≥90 μm, Colour RAL 7039 A Wet lacquerinag Layer thickness ≥90 μm (primer + lacquer finish), Colour RAL 7039 Corrosion protection - Class P100 Degreasing, ironphosphating A Thermoplastic powder coating Layer thickness ≥100 μm, Colour RAL 7001 Continuously welded blades Impeller blades can be continuously welded in order to increase the corrosion resistance when conveying a humid or slightly aggressive medium. The continuous welding has no influence on the material resistance or on the max. tip speed. Continuously welded scroll The casing can be continuously welded in order to increase the corrosion resistance when conveying a humid or slightly aggressive medium. By continuous welding the casing is provided with additional impermeability. A GEH 01 - Casing inside continuously welded A GEH 02 - Casing inside and outside continuously welded 65 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Split Casing There may be a lot of reasons to choose a split casing, the advantages of split casings are: A smaller openings for fan chambers A easier refitting of fan A easier transport to site A easier access to impeller for cleaning and maintenance The joint face on the casing position runs horizontally above or under the fan axis (see drawing). The reinforced side frames are not divisible. The fan is supplied fully assembled. Dimensions in mm, subject to change. a c7 t5 h6 t8 t11 h4 t7 c8 w w RZR RZR a c7c8h4h6t5t7t8t11w 13-19-0500 709 822 950 957 783 410 13-19-0560 785 914 1061 1083 884 458 13-19-0630 872 1021 1188 1204 984 511 13-19-0710 9671143133113501100572 13-19-080010861280149815201245640 13-19-090012191439168617071386719 13-19-100013561568184718691509784 473 531 594 666 749 843 923 409 456 510 571 640 720 784 477 530 594 665 749 843 924 652 743 820 905 1035 1140 1230 Stainless Steel Shaft For applications where there is an increased risk of corrosion, an optional shaft made of stainless steel can be supplied. A ADH / AT / RDH Stainless steel 1.4301 / AISI 304 / XCrNi18-10 A RZR Stainless steel 1.4305 Stainless Steel Nuts and Bolts For applications where there is an increased risk of corrosion, the connecting elements of the fan can be ordered made of stainless steel. Impuls Sensor Thread A tapped hole M6 or M8 can be provided in the pedestal bearing cast housing for admission of sensors to measure the shock impulses. (The measuring connecting piece is not included in the scope of delivery). 66 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Volumeter pin With the flow measuring device it is possible to easily measure/monitor the flow rate after the fan is installed. A pressure tapping at a predetermined position on the inlet cone is provided whereby the differential pressure in relation to the static pressure is measured in front ofthe inlet cone in a static atmosphere. Permissible media temperature: +80 °C (RZR), +70 °C (RDH). qV = K × 2 — × pDü Measuring connector in inlet cone Hose pipe to connecting piece in the side wall Connecting piece (external diameter of 6mm) for the pressure measurement In order to calculate the flow rate, a calibrating factor "K" is required. This factor is determined by comparativemeasurement on a standard test rig. Standard-calibration faktor K Where fans are built into a plenum, the pressure difference between the static pressure in the inlet side plenum and the pressure on the inlet cone is to bemeasured. It must be ensured that the static pressureto be measured in front of the inlet cone is not tampered by dynamic pressure fractions. It is often recommended to arrange a ring of points on the wall facing the outlet side as illustrated in the sketch. When using the K‑factors specified below, a minimum clearance of 0.5×D between the inlet cone of the fan and the side wall of the plenum must be maintained. Indentations that obstruct the flow to the cone canlead to faults when measuring the flow rate. In the event that the differential pressure is fed via a pressure sensor, the signal can also be used for regulating purposes. pin Calibration factors A v olume flow qV [m³/h] A calibration factor K [m²s/h] A density of media r [kg/m³] A pressure difference at cone DpDü [Pa] Type Standard calibration factor K m²s/h IMV 13-0200 IMV 13-0225 IMV 13-0250 IMV 13-0280 IMV 13-0315 IMV 13-0355 IMV 13-0400 IMV 13-0450 IMV 13-0500 IMV 13-0560 IMV 13-0630 IMV 13-0710 IMV 13-0800 IMV 13-0900 IMV 13-1000 IMV 13-1120 IMV 13-1250 IMV 13-1400 IMV 13-1600 100 115 140 165 190 235 290 360 460 560 730 960 1180 1450 1850 2400 3000 3800 4700 Inlet Cones Inlet cone of copper or aluminium prevent the production of sparks during operation. These can be employed when spark protection is required, but ATEX is not mandatory. Hot Dip Galvanised Side Frame Fan Ranges ADH/RDH E4, E6, E7 or K, K1, K2 For applications where an increased corrosion protection is required the reinforcing side frames of the casing can be executed in hot dip galvanisation as an option. 67 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Relubrications Series RZR The lubrication unit IWN allows the fan bearings to be greased even when in operation. The lubrication tubes screwed into the bearing housing are lead out and fastened at the side wall of the fan. If desired, the lubrication tubes can be lead to the drive side of the fan. A IWN 01 - uses standard grease A IWN 11 - uses moisture resistant grease ADH / AT / RDH RZR For more details see "Technical Description" - "Bearings"! Series ADH / RDH The bearing housings of the fan ranges ADH / RDH E4, E6, E7 or K, K1, K2 and AT AR, TIC are equipped with directly fitted grease nipples. Mounting feet Feet made from galvanized steel, either mounted or loose, enable the fan to be installed with a 0, 90 and 270 orientation. Protection guards The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 12100 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. Shaft Guards Contact guard for the free end of the shaft for double inlet centrifugal fans. Models in accordance with DIN EN ISO 13857, made of painted steel mesh. Flanges Made from galvanized or painted steel, to connect ducts and system components to the fan outlet side. Flexible Connections Connecting piece with elastic intermediate section for the vibration or impact-noise decoupled connection of the fan to the system or unit. Made out of two connecting flanges with elastic intermediate section. Temperature range / Application A Standard up to +80 °C A ATEX max. +60 °C 68 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Anti Vibration Mounts AV mounts are designed to prevent noise and vibrations being transmitted through the base of the fan. AV mounts should be mounted beneath the fan base frame so the weight and spring deflections are evenly distributed. They should not be mounted symmetrically because a counter force is induced into the system by the pressure created by the working fan. It is difficult for the manufacturer to establish the position of the AV mounts to suit all types of application. Vibration and noise insulation can also be improved by ensuring that the fan is connected to its external environment by a flexible coupling. Fastening for CC-profile Rubber pads and buffers for both vibration and noise insulation at fan speeds above 1400 rpm or 850 rpm. Fastening for U-profile Rubber buffers for noise insulation only at fan speeds under 800 rpm or 1700 rpm. Spring diffusers with noise insulation layer and height adjustment, for both vibration and noise insulation at fan speeds above 400 rpm. Available AV mounts for different fans, see proSELECTA II. The AVM-mounts are supplied with the suitable mounting material for the base frame. Anti Vibration Rubber Pads E H ZBD ZBD A B C D E G H 21-6035A* 21-6065A* 21-5935A* 21-5950A* 21-6035C* 21-6065C* 21-5935C* 21-5950C* 60 60 90 90 45 45 70 70 35 35 50 50 30 30 45 45 20 20 32 32 5 6 9 9 M6 M6 M10 M10 * A = for U-profile, C = for CC-profile G D C A B Anti Vibration Rubber Buffers K E F H G ZBD ZBD A E F G H K 01-0405A* 03-0503A* 01-0504A* 03-0806A* 03-1007A 03-1510A* 02-2008A* 01-0405C* 03-0503C* 01-0504C* 03-0806C* 03-1007C* 03-1510C* 02-2008C* 20 25 25 40 50 75 100 25 15 20 30 34 50 40 16 11 11 21 26.5 39 44 M 6 M 6 M 6 M 8 M 10 M 12 M 16 M 6 M 6 M 6 M 8 M 10 M 12 M 16 6.5 6.5 6.5 9.5 10.5 12.5 16.5 A * A = for U-profile, C = for CC-profile 69 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories H E Anti Vibration Spring Diffusers ZBD ZBD A B C D ~E ~F G H 60-0101A* 60-0103A* 60-0105A* 60-0108A* 60-0112A* 60-0120A* 60-0130A* 60-0150A* 60-0101C* 60-0103C* 60-0105C* 60-0108C* 60-0112C* 60-0120C* 60-0130C* 60-0150C* 130 130 130 130 150 150 150 150 100 100 100 100 120 120 120 120 70 70 70 70 82 82 82 82 72 72 72 72 92 92 92 92 70-50 70-50 70-50 70-50 90-75 90-75 90-75 110-85 35 35 35 35 35 35 35 35 13 13 13 13 13 13 13 13 M10 M10 M10 M10 M12 M12 M12 M12 G * A = for U-profile, C = for CC-profile B A Anti Vibration Spring Diffusers ~60 M8 M8 ZBD ZBD SP-7701A* SP-7702A* SP-7703A* SP-7704A* SP-7705A* SP-7706A* SP-7707A* SP-7701C* SP-7702C* SP-7703C* SP-7704C* SP-7705C* SP-7706C* SP-7707C* 45 * A = for U-profile, C = for CC-profile 11 95 70 ~106 M10 50 Anti Vibration Spring Diffusers ZBD ZBD SP-7501A* SP-7502A* SP-7503A* SP-7504A* SP-7505A* SP-7506A* SP-7507A* SP-7508A* SP-7501C* SP-7502C* SP-7503C* SP-7504C* SP-7505C* SP-7506C* SP-7507C* SP-7508C* * A = for U-profile, C = for CC-profile 120 150 Anti Vibration Spring Diffusers E H ZBD ZBD E H kg 80-W603A* 80-W605A* 80-W608A* 80-W612A* 80-W616A* 80-W603C* 80-W605C* 80-W608C* 80-W612C* 80-W616C* 68-101 76-101 86-105 84-104 92-105 M 16 M 16 M 16 M 16 M 24 8.3 8.6 9.0 9.3 9.7 14 200 * A = for U-profile, C = for CC-profile 240 270 70 Belt Driven Centrifugal Fans / Fan Set Fan Sets Base Frame with Belt Tensioning Device G2Z-component size 0200/-0500 (only RZR 11/19) This compact base frame with integrated motor tensioning slider provides optimum compactness and easiest handling. A The base frame made of galvanized sheet steel is screwed directly onto the fan (without any casing feet) – the result being the low overall height of the system. A The overall length depending on the casing position and size of the motor is a further factor influencing the optimum compactness. A The integrated tensioning slider considerably simplifies re-adjustment of the belt drive during maintenance and service work. G1Z-component size 0400/-0710 The base frames up to motor size 180 are manufactured from galvanized CC-profiles. The anti-vibration mounts in the CC-profile provide infinitely variable adjustment. From motor size 200 the base frames are of U-profile, welded and painted. Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow for the simple adjustment of the belt tension. G1Z-component size 0800/-1600 Base frame of stable U-profiles, welded and painted, with holes for attaching the antivibration mounts. Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow for the simple adjustment of the belt tension. Equipment A FKS hot-dip galvanized for U-profile base frame Pick-A-Back This allows the motor to be fixed directly onto the fan casing, where space around the fan is limited. One side of the pick-a-back is fixed to the casing so that it swivels, while the other is supported on a spindle. Thus the pick-a-back becomes adjustable to leave room for tensioning the drive belt. The various motor arrangements and casing positions are shown in the drawings. The accompanying tables also show the maximum permissible motor sizes. When using a pick-a-back arrangement and fitting anti vibration mounts (AVM) an additional base frame for fitting the AVM may be required depending on the position of the centre of gravity of the whole fan set. 71 Belt Driven Centrifugal Fans / Fan Set Fan Sets Belt Drive Wedge Belts High performance narrow V-belts in accordance with DIN 7753 are temperature stable up to +80 °C, resistant to mineral oils and electrostatically conductive. The belt pulleys are made of high quality cast iron and, depending on the peripheral velocity and number of grooves, are statically (G 16) or dynamically (G 6.3) balanced. They are fastened to the shaft of the motor or fan by means of a clamping bush. Flat Belts The flat belt drives employed are made using the most modern technology and materials. They are the centrepiece of highly developed, powerful belt drives. This modern flat belt drive has distinct advantages over traditionally employed V-belt drives and exceeds it in efficiency, quiet running and economy. Overview of the advantages: A higher efficiency A longer service life A quieter running A easy to install A low maintenance A no wear on the belt - so it is possible to dispense with the 2nd filter stage in the air conditioning unit (in accordance with VDI 6022) Belt Guard Totally enclosed belt guards are made from galvanised sheet steel in accordance with DIN DIN EN ISO 13857. The front section can be removed for maintenance. If there is no standard belt guard available for the selected belt drive (see table), a suitable belt guard will be made as a welded construction and then coated. Features A belt guard split horizontally A access door on belt guard A opening on belt guard for speed measuring device u4 b8 ~b7 Dimensions in mm, subject to change. l3 a7 l4 ~u3 RBS a7max DWmax b8 b7 s5 u4 u3 l4 l3 01-....-01 01-....-02 01-....-03 01-....-04 01-....-05 01-....-06 01-....-07 01-....-08 01-....-09 01-....-10 01-....-11 01-....-12 01-....-13 01-....-14 01-....-15 01-....-16 01-....-17 01-....-18 01-....-19 250 300 350 400 450 500 600 700 800 900 450 500 600 700 800 900 1000 1100 1200 90 90 160 160 160 160 160 125 125 125 250 250 250 315 315 315 315 315 315 194 194 264 264 264 264 264 264 264 264 344 344 344 484 484 484 484 484 484 159 159 229 229 229 229 229 229 229 229 304 304 304 444 444 444 444 444 444 97 97 132 132 132 132 132 132 132 132 172 172 172 242 242 242 242 242 242 72 72 72 72 72 72 72 72 72 72 122 122 122 122 122 122 122 122 122 69 69 69 69 69 69 69 69 69 69 119 119 119 119 119 119 119 119 119 444 494 614 664 714 764 864 964 1064 1164 794 844 944 1184 1284 1384 1484 1584 1684 404 454 574 624 674 724 824 924 1024 1124 754 804 904 1144 1244 1344 1444 1544 1644 ....Spaceholder for fansize 72 DWmaxDiameter of the biggest pulley a7maxMaximum axle centre distance Belt Driven Centrifugal Fans / Fan Set RZR 11-0200/-0500 Fan set arrangement with base frame Dimensions in mm, subject to change. RD 0 G L90 L90 L0 H0 H0 H90 L0 RD 90 G G0 G90 G0 LG LG 180 G LG 270 G G90 RD RD 180 G L270 RD 270 G L270 L180 H180 H180 H270 L180 P180 H90 LG 90 G G270 G180 H270 LG 0 G G180 G270 P180 G2Z L2 X2 X2 RZRRZR 2 2 2 2 G0 G90 G180G270H0 H90 H180H270 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 625 650 880 650 358 680 710 925 710 404 705 730 974 730 440 725 755 1031 755 489 750 785 1094 785 542 845 885 1207 885 603 990 970 1350 970 671 103010101440 910755 1070105015301050827 RZRRZR 2 2 2 2 L0 L90 L180L270 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 745 740 880 740 100 793 792 925 792 100 843 829 974 829 100 893 876 1031 876 100 952 931 1094 931 100 1087109012071060100 1219112013501120120 1315120314401203120 1400127915301279120 L2 408 467 510 569 623 689 773 868 956 356 401 438 485 537 601 667 750 821 386 431 477 531 597 670 749 840 929 P180X2 Motor Base frame ~ kg max. 396 423 450 482 520 552 587 646 700 132 6 132 7 132 7.5 132 8 132 9 16010 18011 18012 18014 286 322 356 395 438 487 546 612 680 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 73 Belt Driven Centrifugal Fans / Fan Set RZR 11-0400/-0710 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G270 P4 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 P4 G3 G3 H0 G3 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 RZR 2 2 2 2 G0 G90 G180G270 G3 for motor size 63-7180-90100-132160-180 200-225 250-280 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 11-0710-U 1240130016501240 1300135017401298 1434140517721405 1558150819081508 1600157420061574 1708168021451680 1700170021151700 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC – 82-CC 82-CC – 82-CC82-CC ––– RZR H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC 80-U100-U 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 11-0710-U 671 773 667 749 120 755 868 750 840 120 827 956 821 929 120 921 1071 914 1041 150 1028119510211168150 1152134111431316180 1152134111431316180 22531 3 3 22532 3 3 2253360– 2253463– 2253568– 18037 – – 250– 94 145 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 74 X2 275 320 348 384 432 479 – 355 408 452 502 566 625 – 669 275 718 320 766 348 851 384 915432 1014479 – – 3 Dimensions on request 550 614 682 759 846 943 943 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC – 80-U 3– 80-U 3– 80-U 3– 80-U 3– 80-U 3– – – 100-U 120-U 3 Belt Driven Centrifugal Fans / Fan Set RZR 12-0200/-0710 Fan set arrangement with base frame Dimensions in mm, subject to change. G0 RD RD 180 G G3 G180 H180 H180 P3 P1 RD 270 G H270 LG 270 G G90 H270 P2 G90 G270 P4 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 RZR 2 2 2 2 G0 G90 G180G270 G3 for motor size 63-71 80-90 100-132160-180200-225250-280 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 12-0710-U 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1430131216551312 1522138817401388 1610146018301460 1736156119581561 1865167020781670 2008178422351784 2035184022351840 – – –––– – – –––– – – –––– – – –––– – – –––– – – –––– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– – 82-CC 82-CC 82-CC 80-U 3– – 82-CC 82-CC82-CC– – ––– – 100-U 120-U 3 RZR H0 H90 H180H270L2 X2 Motor Base frame ~ kg max. CC 80-U100-U 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 12-0710-U 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 669 769 669 750 120 753 865 753 841 120 825 955 825 931 120 920 1067 920 1046 150 1027119510271173150 1152134111521324180 1152134111521324180 4 4 4 4 4 4 550 614 682 759 846 943 – 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 22531 3 3 22532 3 3 2253360– 2253463– 2253568– 18037 – – 250– 94 155 2T he base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 3 Dimensions on request 4 The RZR 12-0200 to 0355 can only be supplied as standard basic models. 75 Belt Driven Centrifugal Fans / Fan Set RZR 13-0400/-1000 RZR 18-0400/-1000 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 G270 P4 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 G0G90G180G270 G3 for motor size CC2U CC2U CC2U CC2U 63-71 80-90 100-132160-180200-225250-280 RZRRZR 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 RZR RZR 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 1240– 1300– 1650– 1240– 1300– 1350– 1740– 1298– 1411– 1411– 1772– 1411– 1468– 1468– 1908– 1468– 1564– 1564– 2006– 1564– 16601700 16601700 21452115 16601700 –2300 –2300 –2885 –2300 –2410 –2410 –3052 –2410 –2505 –2505 –3180 –2505 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC82-CC100-U120-U 3 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC80-U100-U120-U 671 775 671 775 170 755 868 755 868 170 827 957 827 957 170 921 1083 921 1083 210 1028120410281204210 1152135011521350240 1290152012901520250 1448170714481707260 1577186915771869260 22531 3 3 3 22532 3 3 3 225 3360 – – 225 3463 – – 225 3568 – – 250 37 94 155– 250 – 6798155 280 – 72 105165 280 – 77 111165 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 76 X2 290 316 345 382 410 464 518 570 620 290 316 345 382 410 464 518 570 620 669 290 718 316 766 345 851 382 915410 1014464 1155518 1276570 1317620 3 Dimensions on request 550 614 682 759 846 943 1048 1179 1316 Belt Driven Centrifugal Fans / Fan Set RZR 11-0800/-1000 RZR 15-0400/-1000 RZR 19-0400/-1000 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 G270 P4 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 G0G90G180G270 G3 for motor size CC2U CC2U CC2U CC2U 63-71 80-90 100-132160-180200-225250-280 RZR RZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- 0400 0450 0500 0560 0630 0710 0800 0900 1000 RZR RZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- X2 0400 0450 0500 0560 0630 0710 0800 0900 1000 1240– 1300– 1650– 1240– 1300– 1350– 1740– 1298– 1411– 1411– 1772– 1411– 1468– 1468– 1908– 1468– 1564– 1564– 2006– 1564– 16601700 16601700 21452115 16601700 –2300 –2300 –2885 –2300 –2410 –2410 –3052 –2410 –2505 –2505 –3180 –2505 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC82-CC100-U120-U 3 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC80-U100-U120-U 671 775 671 775 170 755 868 755 868 170 827 957 827 957 170 921 1083 921 1083 210 1028120410281204210 1152135011521350240 1290152012901520250 1444170714441707260 1573186915731869260 22531 3 3 3 22532 3 3 3 225 3360 – – 225 3463 – – 225 3568 – – 250 37 94 155– 250 – 6798155 280 – 72 105165 280 – 77 111165 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 290 316 345 382 410 464 518 570 620 290 316 345 382 410 464 518 570 620 669 290 718 316 766 345 851 382 915410 1014464 1155518 1276570 1317620 550 614 682 759 846 943 1048 1179 1316 3 Dimensions on request 77 Belt Driven Centrifugal Fans / Fan Set AT 7/7-18/18 Fan set arrangement with Pick-A-Back Using these specially designed motor brackets, the motor can be fixed, Pick-A-Back, directly on the scroll of the S-version fans. When the motor must be held on the fan side-frames, the customer will need providing an appropriate slide or bracket, to connect it to the fixing holes on the standard frames. Motor positions Version 1 Version 2 0° 90° 180° 270° Permissible Motor Power 78 Size AT Version 1 ArticleMax. permissible code motor power kW Version 2 ArticleMax. permissible code motor power kW 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 6873030.75 6873030.75 6873080.75 6873120.75 6873140.75 6873180.75 6873200.75 6873350.75 6873380.75 6873460.75 6873480.75 687940– 6879401.1 6879411.1 6879421.5 6879431.5 6879442.2 6879452.2 6875463.0 6879473.0 6879483.0 6879493.0 Belt Driven Centrifugal Fans / Fan Set RZR 11-0200/-0710 RZR 19-0200/-0355 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. LG 90/1 LG 0/1 H15 H17 RD 0/1 RD 90/2 H16 H16 LG 90/2 LG 0/3 H16 LG LG 180/2 H16 RD RD 180/2 LG 270/3 H15 RD 270/3 H15 H16 RD 180/3 H15 H15 H17 LG 180/3 LG 180/1 RD 0/3 H16 RD 180/1 H17 H17 RD 90/1 H15 RD 270/2 LG 270/2 H17 H17 X1 L1 RZRRZR 1 ~ H15 1 ~ H16 1 ~ H17 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 650 720 680 100 700 760 720 100 750 850 810 100 860 930 890 100 880 970 960 100 96010801070100 128012901280120 133014301380120 136014701560120 151016301740150 166018001820150 181019602010180 L1 X1 Motor max. Weight ~ kg 286 322 356 395 438 487 546 612 680 756 843 940 901 1002 1002 1123 1123 1123 132 8 132 8 132 8 13211 16012 16017 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 79 Belt Driven Centrifugal Fans / Fan Set RZR 12-0200/-0710 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. H15 H15 LG 90/1 RD 0/3 H16 LG 90/2 RD 90/1 H17 RD 0/1 LG 0/3 H16 LG LG 180/2 H16 RD 90/2 H16 RD RD 180/2 LG 270/3 H15 RD 270/3 H15 H16 RD 180/3 H15 H15 H17 LG 180/3 LG 180/1 H16 LG 0/1 RD 180/1 H17 H17 RD 270/2 LG 270/2 H17 H17 X1 L1 RZR 1 ~ H15 1 ~ H16 1 ~ H17 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 670 670 690 100 710 730 780 100 850 840 860 100 880 920 930 100 950 950 1030 100 108010901130100 119012901280120 133014301390120 136014701560120 150016201630150 165017901810150 180019502000180 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 80 ~ L1 X1 Motor max. Weight ~ kg 286 322 356 395 438 487 546 612 680 756 843 940 90 1 100 1 100 2 112 2 112 3 112 3 132 7 132 7 132 8 13211 16012 16017 Belt Driven Centrifugal Fans / Fan Set RZR 13-0400/-1000 RZR 18-0400/-1000 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. RD 90/1 H16 H16 LG 90/1 LG 270/3 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 H17 RD 270/3 L1 1 ~ H15 RZRRZR H15 H15 X1 RD RD 180/2 H17 LG LG 180/2 1 ~ H16 1 ~ H17 ~ L1 128013001300170 132014301380170 135015601550170 153017001730210 164018701820210 180019702010240 197021502150250 215024002350260 223026302550260 X1 Motor max. Weight ~ kg 548 612 683 759 845 942 1053 1179 1317 13210 13211 13212 16015 16016 16023 16030 16033 16036 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 81 Belt Driven Centrifugal Fans / Fan Set RZR 11-0800/-1000 RZR 15-0400/-1000 RZR 19-0400/-1000 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. RD 90/1 H16 H16 LG 90/1 LG 270/3 1 ~ H15 0400 0450 0500 0560 0630 0710 0800 0900 1000 1 ~ H16 1 ~ H17 ~ L1 128013001300170 132014301380170 135015601550170 153017001730210 164018701820210 180019702010240 197021502150250 215024002350260 223026302550260 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 82 H17 RD 270/3 L1 RZRRZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- H15 H15 X1 RD RD 180/2 H17 LG LG 180/2 X1 Motor max. Weight ~ kg 548 612 683 759 845 942 1053 1179 1317 13210 13211 13212 16015 16016 16023 16030 16033 16036 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. Pulley-Diameter, Bearings Life Expectency As a principle, the fans are only equipped with noise tested precision bearings designed for a nominal bearing life time (L10h acc. to DIN ISO 281-1) of 40,000 operating hours. In order to not exceed the admitted bearing loads there are minimum pulley diameters defined to be respected when sizing the belt drive. The minimum pulley diameters indicated are to be applied for belt drives selected according to the state of the art and tensioned according to the prescriptions. For flat belt drives the minimum pulley diameters are to be increased of 40 % to the indicated figure! A correct design of a belt drive may be achieved with our selection software where all relevant parameters will be kept automatically. For correct design of a belt drive made by external means, dimensioning and the application of the tensioning forces have to made in full respect of all specification data indicated. Wedge Belts LT / LT = Shaft Centres b = Defection of belt in mm under test force Fp Fp = Test force N as prescribed by Nicotra Gebhardt-Document LT 2 LT / Belt Tensioning The correct tension is achieved when the test force Fp results in a deflection of 16 mm / metre of span. b F 2 p Flat Belts ε* LMu = Measuring Marks 1 before Tensioning LMg = Measuring Marks 1 After Tensioning e* = Stretching Values as specified by Nicotra Gebhardt-Document L Mg L Mu Belt Tensioning The correct belt tension is achieved when the measuring marks LMu have increased by the stretching value e*. This should be carried out in two stages to prevent overstressing of the bearing. Wedge- and Flat Belts = = A further simple method for setting or checking the correct belt tension is via the static frequency of the drive belt. Here the flat or V-belt is set to oscillate freely through striking it whilst stationary. These vibrations are measured using an electronic measuring unit (e.g. a belt tension gauge). The vibration frequency in Hz must then be set to the specified value (documentation / nameplate). 1 = Measuring point Detailed instruction on tensioning are included within the operating and maintenance manuals. 83 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for ADH Fan size 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 84 Fan model E0 / E2 G2E0 / E2 E0 / E2 G2E0 / E2 E0 / E2 / E4 G2E0 / E2 E0 / E2 / E4 G2E0 / E2 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E2 G2E4 G2E7 L/R K K1 K2 G2R G2K G2K2 L/R K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K2 G2K G2K2 Nominal motor power in kW 2.2 63 63 63 63 71 71 80 80 80 80 3 71 71 80 80 95 95 112 100 112 90 100 95 100 112 100 112 4 125 140 140 160 150 112 132 125 5.5 7.5 11 15 140 180 160 18.5 22 224 100 118 160 140 212 150 112 224 112 140 180 224 160 250 160 224 250 160 190 212 224 125 280 180 224 236 224 280 160 180 212 224 140 280 180 212 250 280 160 190 250 212 250 315 160 180 250 300 190 224 180 315 250 315 180 212 250 300 190 160 250 180 212 236 160 224 250 280 180 160 250 180 200 224 180 224 280 355 212 180 212 180 236 200 224 280 200 224 224 212 180 212 180 224 212 236 200 224 250 200 224 224 280 236 200 236 200 280 200 250 180 280 224 224 280 224 224 280 224 224 280 190 224 280 140 90 140 100 180 112 180 118 125 90 180 125 140 112 200 140 180 100 132 112 180 150 140 112 200 150 132 112 180 150 132 100 180 140 200 112 132 118 212 180 140 112 200 160 132 112 200 180 112 100 100 118 112 118 250 180 224 150 224 132 180 150 224 200 132 132 45 55 75 300 300 300 224 200 160 132 37 250 140 112 132 30 180 132 212 180 160 132 215 200 236 160 224 224 160 180 132 200 180 224 150 132 180 180 250 224 180 250 180 160 190 224 250 180 180 200 160 180 180 200 180 212 180 200 280 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for AT Fan size 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 Fan model S / SC G2L / SC2 S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 Nominal motor power in kW 1.1 63 63 63 – 63 – – – 63 – 63 – 63 – – – 63 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 1.5 63 63 63 – 63 – 63 – 71 – 71 – 71 – 71 – 80 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 2.2 80 90 85 – 90 – 90 – 95 – 85 – 95 – 95 – 112 – 71 – 85 – – 90 – 80 – – 85 – 80 – – 80 – 80 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 3 112 118 112 80 125 71 125 85 132 – 112 80 132 – 125 85 140 – 90 – 95 – – 112 – 112 – – 112 – 100 – – 100 – 100 – – 100 – 95 – – 100 – 90 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 4 5.5 7.5 100 140 200 80 100 150 112 150 224 80 112 150 100 150 200 80 180 118 100 150 160 224 90 118 85 118 80 100 140 100 140 85 90 132 90 140 85 – 132 95 132 85 – 132 – 125 – – 132 – 118 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 125 180 118 180 90 112 200 140 200 112 112 180 118 200 112 100 180 132 180 100 100 180 100 180 95 100 180 100 180 95 100 100 – – – – 100 – – – – 100 – – – – 100 – – – – 90 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 180 11 15 160 236 118 118 224 180 190 280 140 140 200 200 160 236 150 118 224 180 180 250 132 118 250 140 250 112 112 250 132 224 112 112 140 112 – 112 – 132 112 – 112 – 132 112 – 112 – 132 112 – 112 – 118 112 – 112 – 112 112 – 112 – 100 112 – 112 – 100 112 – 112 – 100 100 – 100 – 100 100 – 100 – 200 160 224 200 280 160 160 224 224 190 280 160 140 200 160 – 150 – 200 150 – 140 – 200 160 – 140 – 200 150 – 140 – 160 140 – 132 – 150 140 – 132 – 150 132 – 132 – 140 132 – 125 – 140 132 – 125 – 140 125 – 125 – 224 200 280 250 – 200 – 280 224 – 200 – 280 224 – 200 – 280 224 – 200 – 224 200 – 200 – 224 200 – 180 – 200 180 – 180 – 200 180 – 160 – 200 180 – 180 – 200 180 – 160 – 18.5 22 30 37 45 55 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 190 224 250 150 180 190 224 224 150 180 190 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 212 224 150 180 190 224 224 150 180 190 212 224 150 180 190 224 224 250 280 – 280 – 250 – 250 – 280 – 250 – 280 – 250 – 250 – 224 – 250 224 – 224 – 250 224 – 200 – 250 224 – 224 – 250 224 – 200 – 85 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for RDH Fan size Fan model 0180 0200 0225 E0 / E2 E0 / E2 / E4 E0 / E2 / E4 E0 / E2 E4 G2E4 G2E7 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E4 G2E7 E0 / E2 E4 E6 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E2 G2E4 G2E7 R K K1 K2 G2K G2K2 R K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K2 G2K G2K2 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 86 Nominal motor power in kW 2.2 63 63 63 3 63 63 63 71 71 80 4 71 80 71 80 80 5.5 7.5 90 90 85 100 90 112 90 100 90 118 90 80 90 85 100 90 90 112 100 15 18.5 22 180 118 140 150 125 160 180 125 140 125 160 30 37 45 55 75 100 90 125 112 90 100 90 112 112 100 125 90 140 100 112 112 112 125 112 100 118 125 132 132 100 11 112 125 112 118 112 132 112 180 140 140 112 160 150 118 150 140 180 150 112 140 140 180 150 200 140 224 200 160 212 150 125 200 150 200 140 150 180 160 140 212 160 160 200 280 180 150 236 180 190 180 200 280 355 250 315 180 224 250 200 180 200 280 250 280 180 212 180 190 250 160 180 250 212 250 224 250 315 180 236 315 190 224 280 140 118 224 150 180 250 200 140 190 180 224 224 200 250 180 250 212 224 212 224 224 224 224 224 224 250 280 280 224 224 280 224 224 280 224 224 300 224 224 280 280 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for RZR Fan size Fan model 0200 Nominal motor power in kW 3 4 5.5 7.5 11 / 12 / 19 71 71 71 90 0225 11 / 12 / 19 71 71 80 100 0250 11 / 12 / 19 71 71 90 112 15 18.5 22 30 11 / 12 71 71 90 118 19 71 71 71 85 11 / 12 71 85 106 132 19 71 71 75 95 11 / 12 75 95 118 150 19 71 71 85 106 11 / 12 71 80 100 125 13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 180 11 / 12 71 90 112 140 13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 200 11 / 12 80 100 125 160 13 / 15 / 18 / 19 71 71 71 80 106 132 160 180 224 11 / 12 71 71 85 112 150 190 13 / 15 / 18 / 19 71 71 71 71 90 112 132 150 190 224 11 / 12 71 80 100 132 180 224 13 / 15 / 18 / 19 71 71 71 75 100 125 150 170 224 250 11 / 12 71 85 112 140 190 236 280 13 / 15 / 18 / 19 71 71 71 71 85 106 118 140 180 11 80 100 125 160 224 280 315 355 13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 11 95 118 150 200 280 355 400 450 13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 11 112 140 180 224 315 400 450 500 13 / 15 / 18 / 19 71 71 71 71 95 118 140 1120 13 – – – – 315 315 1250 13 – – – – 315 1400 13 – – – – 1600 13 – – – – 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 11 37 45 55 75 90 110 132 212 250 280 212 236 280 315 180 212 250 300 375 160 212 236 280 315 425 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 160 200 355 355 400 450 315 355 355 400 400 450 315 315 355 355 400 400 450 450 315 315 355 355 400 400 450 500 250 112 125 140 560 For flat-belt-drives the listed recommended pulley diameter mus be enlarged up to approx. 40 %. 87 Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description Description General The high-performance centrifugal fans are the result of extensive and systematic development work. These technically first-rate products are distinguished by their high efficiency, the large pressure differences attainable and low noise levels. The sizes are geometrically scaled in accordance with the standard range R 20 and the nominal size stated is the external diameter of the impeller. Media The fans are suitable for handling air and other non aggressive gases from -20 °C up to +80 °C, resp. +100 °C. The ambient temperature at the drive motor must not exceed +40 °C. Protective installations The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 12100 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. Shafts Shafts ADH / AT / RDH The fan shafts are manufacrured of ground, precisely rounded carbon steel C40. They are principally prepared without being stepped at both ends. The shafts of the RDH K1 and K2 ranges, size 1000 are machined on both ends for fitting a pulley. ADH / AT from size 12/9 / RDH The shafts are equipped with a keyway (open shape) at both ends and a key (type 2). AT 7/7 up to 10/10 The standard construction is the version with flats on shaft ends (type 1), it is also available the version with keyways (type 2). For corrosion protection the shafts are galvanised up to fan size 0560 and 30/28. From size 0630 and larger the shaft are covered, between bearing and hub, with a paint in order to ensure corrosion protection. The shaft ends are covered with a wax product easy to remove. Shafts RZR The shafts are manufacured of precisely rounded carbon steel C35, pared and polished. Up to size 1000 they are not stepped at the shaft end. For sizes 1120 up to 1600 the shafts are machined on both ends for fitting a pulley. The shafts are equipped with a keyway at both ends and a key executed according to DIN 6885-1. A Groove shape N2 (open) Sizes 0200 up to 1000 A Groove shape N1 Sizes 1120 up to 1600 The shafts are covered with a easily removable wax product for corrosion protection. Housig feet / Side frames ADH / AT / RDH For easier installation of the fan the mounting feet and reinforcing frames are provided with eye holes. 88 Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description Description Bearings ADH / AT / RDH ADH E0 / ADH L ADH E2 / ADH R AT S / AT SC AT G2L / AT SC2 RDH E0 RDH E2 / RDH R Maintenance free, self aligning radial insert ball bearings, mounted in pressed steel housing/strut assemblies with rubber interliners. ADH E4 / ADH K AT AR / AT TIC / AT G2C RDH E4 / RDH K Monobloc pedestal cast iron pillow block bearings with relubrication nipple, mounted on a robust frame. Integrated, maintenance free self aligning radial ball bearings, fixed by eccentric clamp. ADH E6 / ADH K1 / ADH E7-0500 RDH E6 / RDH K1 / RDH E7-0500 Pilow block cast iron bearings with relubrication nipple, mounted on a robust frame. Integrated self aligning radial ball bearings, fixed by conical sleeve and locknut. ADH E7-0560; ADH K2-0630/-0800 AT G2C-C2 RDH E7-0560; RDH K2-0630/-0800 Split-type plummer block bearings with relubrication nipple, mounted on a robust frame, integrated self aligning double row ball-bearings fixed by conical sleeve, lubricated with long life high performance grease. ADH K2-0900-1000 RDH K2-0900-1000 RDH X1 RDH X2 Single piece plummer block housing, with grease nipple, mounted on robust pedestal, equipped with self aligning double row roller bearing, fixed to impeller shaft by a concentric shaft clamp, lubricated with long life high performance grease. Twin Fans The twin fans up to size 0630 are equipped with one single shaft and 3 bearings. From size 0710 the two separate fans are connected by an elastic coupling. For the models G2K2 the bearings from size 0710 and larger are – due to different loads – of a different execution inside compared to outside. 89 Belt Driven Centrifugal Fans / Description Description Bearings RZR RZR 11-0200/-1000; RZR 12-0200/-0710 (without lubricators) Radial insert ball bearings with spherical outer Ring mounted in pressed steel housing/strut assemblies with rubber interliners. RZR 11-0200/-0710; RZR 12-0200/-0710 (with relubricators) Radial insert ball bearings with spherical outer Ring mounted within cast iron housing, supported from the fan casing by tubular struts. Relubrication is effected via extended tubes and nipples. RZR 19-0200/-0355 (without lubricators) Radial insert ball bearings with spherical outer Ring mounted within cast iron housing, supported from the fan casing by tubular struts. RZR 19-0200/-0355 (with relubricators) Relubrication is effected via extended tubes and nipples. RZR 15-0400/-1000; RZR 19-0400/-1000 (without lubricators) Self aligning double row ball bearings secured by adapter sleeve, mounted within a cast iron housing. RZR 15-0400/-1000; RZR 19-0400/-1000 (with relubricators) Relubrication is effected via extended tubes and nipples. RZR 13-0400/-1600; RZR 18-0400/-1000 (without lubricators) Self aligning double row ball bearings within standard plummer blocks, mounted on robust pedestal. RZR 13-0400/-1600; RZR 18-0400/-1000 (with relubricators) Relubrication is effected via extended tubes and nipples. Lubricators for relubrication during operation The Bearings are charged with long life high performance grease. Relubrication is effected via extended tubes and nipples. See operating and maintenance instructions. A IWN 01 - Standard grease, Gadus S2 V100 3 A IWN 11 - Klüber-Staburags NBU12/300KP 90 Belt Driven Centrifugal Fans / Description Description Motors Standard motors of wellknown brands, type of protection IP55, thermal class F, are used. During commissioning and maintenance the detailed instructions provided by the motor manufacturer (type plate/motor operating instructions) must be followed, this also applies to the motor protection devices required onsite. The motors are equipped with PTC resistors/temperature sensors as standard. Motors with integrated frequency inverters may be supplied on request. EX-ATEX motors Fan sets of centrifugal fans according to Ex-ATEX execution are equipped with motors of the correspondent category. For frequency inverter operation the motors will be of pressure resistant execution. Speed regulation A suitable speed variation system is required for the optimum adjustment of the desired operating point. Our frequency converters are perfectly tuned for the operation of RZR centrifugal fans. The use of the newest power semi-conductors guarantees high efficiency and minimum motor noise thanks to the especially fine pulse pattern. See also the technical description "Performance". Electric connection Centrifugal fan systems are delivered ready for installation. The motor terminal box can be easily accessed. Electric installation must be carried out according to the applicable provisions in compliance with local regulations. A terminal board circuit diagram showing correct connection is enclosed with every motor. Attachment points on the side plates ADH/RDH ADH/RDH 0160/-0180 g m hh d p 0160 0180 a 281 310 b 291 326 c 205 229 d 141 157 e 119 131 f 172 195 g 140 153 h 30 30 m 92 92 n 121 141 p 67 81 r 155 175 s 101 115 ø 4 4 p s e hh b m r c n f ø a hh ADH/RDH 0200/-0250 g a h h z d 0200 0225 0250 a 341 379 416 0200 0225 0250 p 134 152 171 x u p e h h b m c n v r f ø m m s h h m s b 362 407 452.5 r 202 229 256 c 256 288 322 s 129 149 172 d 177 199 221 e 147 165 183.5 t 163 185 208 f 215 242 269 u 126 142 155 g 164 180 195 v 190 219 244 h 40 40 40 z 94 114 137 m 110 110 110 x 91 107 120 n 155 184 209 ø 4 4 4 t 91 Belt Driven Centrifugal Fans / Description Description Attachment points on the side plates ADH/RDH ADH/RDH 0280/-0315 ø g a h 0280 0315 d h a b c d e f g h 464 508 361 249 206 302 215 113 515 571 404 279 232 339 236 113 m 71 71 n p r s t u v ø 170 191 287 169 233 150 245 6.2 195 215 323 197 263 175 284 6.2 n u p e h b h c v r f Scroll dimensions are refered to the external surface of the back plate m h s t ADH/RDH 0355/-0450 g o h s h d h h u p e n m b c v r f ø a m h 0355 0400 0450 a 576 644 721 b 643 733 817.5 c 453 507 569 d 315 354 399 e 261 302 332.5 f 382 431 485 g 261 290 322 h 156 156 213 m 158 186 168 0355 0400 0450 n 197.5 220 245 o 197.5 230 256 p 241 275 311 r 364 411 466 s 204 243 271 t 295 336 379 u 158 186 168 v 295 346 350 ø 6.2 6.2 M10 Scroll dimensions are refered to the external surface of the back plate t ADH/RDH 0500 g o h w s h w d 0500 a 794 b 906 c 638 d 442 e 368 f 538 g 352 h 231 m 439 n 220 0500 o 281 p 349 r 519 s 280 t 423 u 207 v 400 k 354 w 181 ø M10 Scroll dimensions are refered to the external surface of the back plate u h u p e b h v c m k n r f ø a h h t ADH/RDH 0560/-0710 o h w s h w d u h u p e x b h v c m k n ø a r f g h z h 0560 0630 0710 a 886 993 1119 b 1016 1142 1295 c 715 801 898 d 496 559 634 e 413 463 530 f 603 679 765 g 390 434 485 h 235 235 265 m 490 553.5 626.5 n 245 260 267.5 o 310 353 393 0560 0630 0710 p 389 441 496 r 581 656 737 s 362 431 476 t 472 521 605 u 276 328 371 v 494 567 637 z 310 356 397 x 140 160 200 k 394 – – w 180 – – ø M10 M10 M10 Scroll dimensions are refered to the external surface of the back plate t Screw to be used to attach mounting feet 92 Size Type of screw 0160/-0250 0280/-0400 0450/-0710 Self-threading screw Self-threading screw Metric screw Thread AB 6.3 ISO 1478 AB 8 ISO 1478 M10 ISO 724 Belt Driven Centrifugal Fans / Description Description Operating limits ADH Permissible Permissible Permissible nominal fan speed bearing motor load power ADH kW 1/min N E0-0160 E2-0160 G2E0-0160 G2E2-0160 E0-0180 E2-0180 G2E0-0180 G2E2-0180 E0-0200 E2-0200 E4-0200 G2E0-0200 G2E2-0200 E0-0225 E2-0225 E4-0225 G2E0-0225 G2E2-0225 E0-0250 E2-0250 E4-0250 G2E0-0250 G2E2-0250 G2E4-0250 G2E7-0250 E0-0280 E2-0280 E4-0280 G2E0-0280 G2E2-0280 G2E4-0280 G2E7-0280 E0-0315 E2-0315 E4-0315 E6-0315 G2E0-0315 G2E2-0315 G2E4-0315 G2E7-0315 E0-0355 E2-0355 E4-0355 E6-0355 G2E0-0355 G2E2-0355 G2E4-0355 G2E7-0355 E0-0400 E2-0400 E4-0400 E6-0400 G2E0-0400 G2E2-0400 G2E4-0400 G2E7-0400 E0-0450 E2-0450 E4-0450 E6-0450 G2E0-0450 G2E2-0450 G2E4-0450 G2E7-0450 3 3 3 4 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 7.5 4 4 7.5 15 5.5 5.5 11 5.5 5.5 11 22 5.5 5.5 11 18.5 5.5 5.5 11 30 7.5 7.5 15 22 7.5 7.5 15 30 7.5 7.5 15 22 7.5 7.5 15 37 11 11 15 30 11 11 15 37 4200 4200 3400 3400 4000 4000 3200 3200 3800 3800 3800 2900 2900 3400 3400 3400 2600 2600 2800 2800 3000 2200 2200 2300 2800 2500 2500 2700 2000 2000 2200 2400 2100 2100 2400 2400 1600 1600 1900 2100 1800 1800 2000 2000 1500 1500 1700 1900 1600 1600 1800 1800 1200 1200 1400 1800 1400 1400 1500 1500 1000 1000 1200 1400 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 450 420 420 450 1250 530 530 660 530 530 660 1700 530 530 660 1050 530 530 660 2000 840 840 940 1450 840 840 940 2000 840 840 940 1450 840 840 940 2950 1180 1180 1320 1800 1180 1180 1320 2950 Permissible Fan media weight temperature °C kg ADH Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 5 6.6 10.5 14.5 6 7.8 12.6 17 7.1 9.1 12.6 15 20 8.5 10.7 14.5 18 24 10.5 13 18 22 29 38 44 14.2 18 24 30 39 50 59 18 22 29 30 38 48 60 73 23 29 41 42 49 63 84 98 31 38 52 53 66 82 108 133 42 50 66 67 90 107 135 159 E0-0500 E2-0500 E4-0500 E6-0500 E7-0500 G2E0-0500 G2E2-0500 G2E4-0500 G2E7-0500 E0-0560 E2-0560 E4-0560 E6-0560 E7-0560 G2E2-0560 G2E4-0560 G2E7-0560 L-0630 R-0630 K-0630 K1-0630 K2-0630 G2R-0630 G2K-0630 G2K2-0630 L-0710 R-0710 K-0710 K1-0710 K2-0710 G2K-0710 G2K2-0710 K-0800 K1-0800 K2-0800 G2K-0800 G2K2-0800 K-0900 K1-0900 K2-0900 G2K-0900 G2K2-0900 K-1000 K1-1000 K2-1000 G2K-1000 G2K2-1000 11 11 15 30 37 11 11 15 45 15 15 18.5 30 45 15 18.5 45 15 15 18.5 30 45 15 18.5 55 18.5 18.5 22 37 55 30 75 22 37 55 30 75 30 45 75 37 75 37 45 75 37 75 1200 1200 1300 1400 1400 900 900 1000 1400 1100 1100 1200 1300 1300 800 900 1200 900 900 1000 1100 1100 700 750 1000 750 750 850 900 900 700 800 750 800 800 600 700 650 700 700 500 600 600 600 650 450 500 1180 1180 1320 1800 2200 1180 1180 1320 4000 1450 1450 1760 2550 3700 1450 1760 4000 1450 1450 1760 2550 3700 1450 1760 4000 1800 1800 1900 3550 5800 3000 7000 1900 3550 5800 3000 7000 3000 3900 7000 3000 7000 3000 3900 7000 3000 7000 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 57 65 85 86 105 120 140 176 221 72 86 134 142 150 185 268 319 91 106 170 175 180 230 342 393 118 135 201 208 225 532 537 249 261 278 665 670 306 316 320 801 806 333 356 360 894 899 93 Belt Driven Centrifugal Fans / Description Description Operating limits AT Permissible Permissible Permissible nominal fan speed bearing motor load power AT kW 1/min N S-7/7 SC-7/7 G2L-7/7 SC2-7/7 S-9/7 SC-9/7 AR-9/7 G2L-9/7 SC2-9/7 G2C-9/7 S-9/9 SC-9/9 AR-9/9 G2L-9/9 SC2-9/9 G2C-9/9 S-10/8 SC-10/8 AR-10/8 G2L-10/8 SC2-10/8 G2C-10/8 S-10/10 SC-10/10 AR-10/10 G2L-10/10 SC2-10/10 G2C-10/10 S-12/9 SC-12/9 AR-12/9 G2L-12/9 SC2-12/9 G2C-12/9 G3C-12/9 S-12/12 SC-12/12 AR-12/12 G2L-12/12 SC2-12/12 G2C-12/12 G3C-12/12 S-15/11 SC-15/11 AR-15/11 G2L-15/11 SC2-15/11 G2C-15/11 G3C-15/11 S-15/15 SC-15/15 AR-15/15 G2L-15/15 SC2-15/15 G2C-15/15 G3C-15/15 94 3 3 3 3 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 4 4 7.5 3 3 7.5 5.5 5.5 11 5.5 5.5 11 11 5.5 5.5 11 5.5 5.5 11 11 5.5 5.5 11 5.5 5.5 11 15 5.5 5.5 11 5.5 5.5 11 15 2600 2600 2400 2600 2500 2500 2500 2400 2500 2500 2100 2100 2100 2000 2100 2100 2500 2500 2500 2100 2500 2500 2000 2000 2000 1800 2000 1700 2000 2000 2000 1800 2000 2000 2000 1500 1500 1500 1400 1500 1400 1400 2000 2000 2000 1400 2000 1500 1500 1200 1200 1200 1100 1200 950 1000 350 350 350 350 350 350 620 350 350 1000 350 350 620 350 350 1000 350 350 620 350 350 1000 350 350 620 350 350 1000 620 620 1000 620 620 1200 1200 620 620 1000 620 620 1200 1200 620 620 1000 620 620 1200 1600 620 620 1000 620 620 1200 1600 Permissible Fan media weight temperature °C -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 kg 5 6 11.7 13.7 6.6 8.3 8.3 14.9 18 23.5 7.9 9.5 9.5 18.1 21.8 27 8.3 9.8 9.8 18.5 21.8 27 9.3 11 11 21.1 23.5 31 12.7 16 16 28.2 34.8 45.5 70 15.2 18.4 18.4 33.8 40.2 51 81 17.7 20.9 20.9 39.7 46.1 57.4 90 20.6 24.5 24.5 45.3 53.1 68 108 AT S-18/13 SC-18/13 AR-18/13 G2L-18/13 SC2-18/13 G2C-18/13 G3C-18/13 S-18/18 SC-18/18 AR-18/18 G2L-18/18 SC2-18/18 G2C-18/18 G3C-18/18 TIC-20/15 G2C-20/15 G2CC2-20/15 G3C-20/15 G3CC2-20/15 TIC-20/20 G2C-20/20 G2CC2-20/20 G3C-20/20 G3CC2-20/20 TIC-22/15 G2C-22/15 G2CC2-22/15 G3C-22/15 G3CC2-22/15 TIC-22/22 G2C-22/22 G2CC2-22/22 G3C-22/22 G3CC2-22/22 TIC-25/20 G2C-25/20 G2CC2-25/20 G3C-25/20 G3CC2-25/20 TIC-25/25 G2C-25/25 G2CC2-25/25 G3C-25/25 G3CC2-25/25 TIC-28/20 G2C-28/20 G2CC2-28/20 G3C-28/20 G3CC2-28/20 TIC-28/28 G2C-28/28 G2CC2-28/28 G3C-28/28 G3CC2-28/28 TIC-30/20 G2C-30/20 G2CC2-30/20 G3C-30/20 G3CC2-30/20 TIC-30/28 G2C-30/28 G2CC2-30/28 G3C-30/28 G3CC2-30/28 Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N Permissible Fan media weight temperature 7.5 7.5 15 7.5 7.5 15 15 7.5 7.5 15 7.5 7.5 15 15 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 1200 1200 1200 1100 1200 1200 1000 1100 1100 1100 800 800 1000 700 1300 1300 1300 900 1100 1300 900 1200 700 800 1300 1300 1300 800 1000 1200 900 1000 600 800 1000 700 800 600 700 900 700 800 500 600 800 600 800 600 650 800 600 700 400 550 800 600 700 550 600 800 600 700 400 500 620 620 1200 620 620 1600 1600 620 620 1200 620 620 1600 1600 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1600 1600 6500 1600 6500 1600 1600 6500 1600 6500 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 °C kg 27 33 33 57.8 69.8 91 118 32.5 38.2 38.2 70.5 81.9 106 137 71 137 144 315 319 78 150 158 355 359 73 141 148 340 347 82.5 165 173 425 438 93 195 202 432 436 105 202 210 480 484 120 210 218 474 478 127 235 244 539 543 131 245 253 505 509 138 302 310 577 581 Belt Driven Centrifugal Fans / Description Description Operating limits RDH Permissible Permissible Permissible nominal fan speed bearing motor load power RDH kW 1/min N E0-0180 E2-0180 E0-0200 E2-0200 E4-0200 E0-0225 E2-0225 E4-0225 E0-0250 E2-0250 E4-0250 G2E4-0250 G2E7-0250 E0-0280 E2-0280 E4-0280 G2E4-0280 G2E7-0280 E0-0315 E2-0315 E4-0315 E6-0315 G2E4-0315 G2E7-0315 E0-0355 E2-0355 E4-0355 E6-0355 G2E4-0355 G2E7-0355 E0-0400 E2-0400 E4-0400 E6-0400 G2E4-0400 G2E7-0400 E0-0450 E2-0450 E4-0450 E6-0450 G2E4-0450 G2E7-0450 E0-0500 E2-0500 E4-0500 E6-0500 E7-0500 G2E4-0500 G2E7-0500 E0-0560 E2-0560 E4-0560 E6-0560 E7-0560 G2E4-0560 G2E7-0560 R-0630 K-0630 K1-0630 K2-0630 G2K-0630 G2K2-0630 2.2 2.2 3 3 3 4 4 4 4 4 5.5 5.5 7.5 5.5 5.5 7.5 5.5 11 5.5 5.5 7.5 11 5.5 11 7.5 7.5 11 15 7.5 11 7.5 7.5 15 22 7.5 18.5 11 11 15 30 11 18.5 11 11 15 30 37 11 30 15 15 18.5 30 37 11 30 15 18.5 30 45 15 37 6800 6800 6000 6000 6800 5800 5800 6000 4600 4600 5400 2900 3500 4000 4000 4700 3000 3400 3500 3500 4100 4500 2200 3300 3300 3300 3800 4000 2000 2600 2700 2700 3100 3500 1600 2800 2500 2500 2800 3200 1400 2200 2100 2100 2350 2650 2800 1200 2200 1950 1950 2100 2400 2600 1100 1900 1600 1700 2000 2300 1000 1400 420 420 420 420 420 420 420 420 420 420 450 450 660 530 530 660 660 940 530 530 660 1050 660 1320 840 840 940 1450 940 1320 840 840 940 1450 940 1760 1180 1180 1320 1800 1320 1760 1180 1180 1320 1800 2200 1320 3000 1450 1450 1760 2550 3700 1760 3000 1450 1760 2550 3700 1760 3000 Permissible Fan media weight temperature °C kg RDH Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 5.3 7.1 6.6 8.5 11.8 7.8 9.9 13.6 13.3 15.7 21 46 49 17.8 21 28 61 65 21 25 32 34 70 79 29 34 46 47 104 109 36 42 57 58 126 144 50 57 73 75 160 176 62 70 90 92 110 197 235 79 92 141 148 153 301 336 119 173 180 185 370 408 R-0710 K-0710 K1-0710 K2-0710 G2K-0710 G2K2-0710 K-0800 K1-0800 K2-0800 G2K-0800 G2K2-0800 K-0900 K1-0900 K2-0900 G2K-0900 G2K2-0900 K-1000 K1-1000 K2-1000 G2K-1000 G2K2-1000 X1-1120 X2-1120 X1-1250 X2-1250 X1-1400 X2-1400 15 22 37 55 30 75 22 37 55 30 75 30 45 75 37 75 37 45 75 37 75 55 110 75 132 90 160 1300 1500 1700 2000 1400 1700 1200 1400 1650 1150 1400 1100 1250 1500 1000 1100 1000 1000 1300 800 800 900 1170 800 1050 720 930 1800 1900 3550 5800 3000 7000 1900 3550 5800 3000 7000 3000 3900 7000 3000 7000 3000 3900 7000 3000 7000 8000 8000 8000 10000 9000 12500 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 165 220 240 250 580 586 270 297 305 747 753 343 355 375 883 889 415 430 450 1048 1054 610 890 950 1140 1370 1390 95 Belt Driven Centrifugal Fans / Description Description Operating limits RZR Permissible Permissible Permissible nominal fan speed bearing motor load power RZR kW 1/min N 11-0200 12-0200 19-0200 11-0225 12-0225 19-0225 11-0250 12-0250 19-0250 11-0280 12-0280 19-0280 11-0315 12-0315 19-0315 11-0355 12-0355 19-0355 11-0400 12-0400 15-0400 19-0400 18-0400 13-0400 11-0450 12-0450 15-0450 19-0450 18-0450 13-0450 11-0500 12-0500 15-0500 19-0500 18-0500 13-0500 11-0560 12-0560 15-0560 19-0560 18-0560 13-0560 11-0630 12-0630 15-0630 19-0630 18-0630 13-0630 11-0710 12-0710 15-0710 19-0710 18-0710 13-0710 11-0800 15-0800 19-0800 18-0800 13-0800 11-0900 15-0900 19-0900 96 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 11 7.5 7.5 11 7.5 7.5 11 7.5 7.5 30 30 30 30 7.5 7.5 30 30 30 30 7.5 7.5 30 30 30 30 15 15 37 37 37 37 15 15 37 37 37 37 18.5 18.5 55 55 55 55 22 55 55 55 55 22 75 75 7490 7490 7490 6640 6640 6640 5250 5250 5970 5235 5235 5300 4418 4418 4730 3200 3200 4187 3027 3027 3600 3600 3600 3600 2504 2504 3360 3360 3360 3360 2050 2050 2920 2920 2920 2920 2205 2205 2400 2400 2490 2490 1838 1838 1880 1880 2380 2380 1627 1627 2000 2000 2120 2120 1300 1470 1470 1700 1700 1000 1430 1430 480 480 480 500 500 500 540 540 540 630 630 850 660 660 910 720 720 950 1020 1020 1970 1970 1970 1970 1080 1080 2000 2000 2000 2000 1140 1140 2040 2040 2040 2040 1830 1830 2950 2950 2950 2950 1960 1960 3000 3000 3000 3000 2080 2080 4400 4400 4400 4400 2150 4500 4500 4500 4500 2180 6000 6000 Permissible Fan media weight temperature °C kg RZR Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 11 12 13 13 15 16 15 17 17 20 23 23 24 27 28 33 36 39 43 49 61 66 70 75 54 60 73 82 83 92 65 72 94 105 105 116 103 109 125 136 140 151 124 132 149 162 167 180 177 194 201 225 230 254 250 250 280 289 319 358 358 396 18-0900 13-0900 11-1000 15-1000 19-1000 18-1000 13-1000 13-1120 13-1250 13-1400 13-1600 75 75 22 75 75 75 75 132 160 200 250 1540 1540 800 1140 1140 1400 1400 1220 1100 1000 860 6000 6000 2200 6200 6200 6200 6200 10000 15000 20000 20000 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 409 447 416 416 462 471 517 710 1100 1390 1870 Belt Driven Centrifugal Fans / Description Description Performance The curves show the total pressure rise pF as a function of the volume flow rate qV plotted in a double logarithmical diagram. The throttle curves (system resistance parabolas) are then represented by straight lines. The curves are established with a reference density of r1 = 1.2 kg/m³ at the fan intake. The pressure and impeller input power are directly proportional to density r1. Outlet velocity v2 and the dynamic pressure pd2 refer to the flanged cross section area at the fan discharge. psF = pF – pd2 The increase in static pressure psF when a duct is fitted to the discharge (Installation B) can be calculated from the equation: psF = pF – fpd × pd2 Where no duct is fitted (Installation A) there is no static pressure regain. The increase in pressure psF can be calculated from formula: The limits of application indicated in the fan curves (by blue dotted lines) outline the recommended functional range of the fans, where a stable operation with high efficiency can be expected. The efficiency marked on the straight system lines is only applicable at the maximum fan speed Nmax; it decreases with lower fan speed. RDH ADH 0160/-0560 0630/-1000 fpd 1.9 1.66 RZR 0200/-1000 see fan curves RZR 0180/-1000 1.74 1120/-1400 1.15 1120/-1600 1.00 10/10 2.24 22/22 2.42 12/12 1.94 25/25 2.49 15/15 2.17 30/20 2.44 AT fpd fpd Pr a = r ×— Pr + Pb 7/7 1.96 18/18 1.86 9/7 2.16 20/15 2.48 9/9 1.95 20/20 2.26 10/8 2.08 22/15 2.46 12/9 1.83 25/20 2.48 15/11 2.10 28/20 2.37 18/13 1.98 30/28 2.41 Efficiency ADH / AT / RDH The performance curves Pr of the fan curve diagram correspond to the absorbed power of the fan impeller. The vertical scales shown at the right side of the diagram indicate the bearing power loss Pb of the different fan executions and depending on the fan speed. The resulting power absorbed on fan shaft is found by adding the absorbed power Pr of the fan impeller and the bearing power losses Pb. As a consequence the resulting fan efficiency is to be calculated according to the formula: Efficiency RZR The actual efficiency value for a fan speed lower Nmax is calculated by multiplying the efficiency at Nmax by the factor fh for the appropriate speed. (fh to be found with the scale on the right side of the page). PN Pa × fP Motor nominal power ADH / AT / RDH / RZR To determine the motor rating PN, the fan absorbed shaft power Pr must be increased by a safety factor to accommodate belt drive losses and possible fan speed differences. The factor fp is an estimated value. As an approximate value, the figures below are suggested. ADH / AT Pa < 0.75 kW Pa ≥ 0.75 kW ... < 10kW Pa ≥ 10 kW RDH / RZR fp = 1.30 fp = 1.20 fp = 1.15 Pa < 0.75 kW Pa ≥ 0.75 kW ... < 10 kW Pa ≥ 10 kW fp = 1.25 fp = 1.15 fp = 1.12 97 Belt Driven Centrifugal Fans / Description Description Performance 8 × J × N² tA =— PN × 106 When selecting the motor, the run up time must be checked whether being within permitted limits. The run up time can be worked out approximately according to the following formula: where: tA = run time in seconds J = moment of inertia in kgm² N = fan speed in rpm PN = nominal motor power in kW (Impeller weight and moment of inertia can be found on the performance diagram for each fan size.) If tA exceeds the motor manufacturer‘s recommendation or the tripping period of the electrical gear, a larger motor must be used or the starting gear has to be selected for heavy starting. 1 = Test fan 2 = Discharge duct 3 = Screen 4 = Multiple nozzles 5 = Auxiliary fan and damper Fan curves measurement ADH / AT / RDH - AMCA 210-99 / ISO 5801 1 2 3 4 5 pe4 1 = Test fan 2 = Discharge duct acting as a pressure regain unit 3 = Screen 4 = Variable damper 5 = Compensating fan 6 = Flow straightener 7 = Inlet cone pe6 p Fan curves measurement RZR - ISO 5801 / DIN 24163 2 1 3 4 5 6 pa ta t1 psF qV = f(po) 7 po Performance data of twin fan units The performance data of twin fan units (Identification "G2") can be calculated, starting from that in the corresponding operating point of a single fan, with the following formulas: A Fan Pressure: pF G2 = pF × 1 A Volume flow rate: qV G2 = qV × 2 A Fan shaft power: Pa G2 = Pa × 2,15 AR otational speed: N G2 = N × 1,05 A Sound:LWA G2 = LWA + 3 dB AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0180 to 0560, ADH and RDH fans of the L, R, K, K1 and K2 versions, from sizes 0630 to 1000, AT fans of the S, SC, C and TIC versions, from sizes 7/7 to 30/28, shown herein are licensed to bear the AMCA Seal. Nicotra Gebhardt GmbH (Germany) certifies that RZR fans of the 11, 12, 15 versions, from sizes 0355 to 1000, shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Air performance with Installation Type “A” (“with free outlet”), and that of the twin fan versions G2L, G2R, G2K, G2K2, G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2, and that of the triple fan versions G3C and G3C-C2 in any installation type is not AMCA licensed. 98 Belt Driven Centrifugal Fans / Description Description Sound Noise measurements are undertaken in accordance with DIN 45635-38 “Noise Measurement of Machines: Fans”. Induct Method for the Discharge The induct method is specified with DIN EN ISO 5136. It determines the sound power emitted at discharge of a test fan. The test duct, as a main feature, is equipped with an anechoic termination fitted to avoid end reflection going back into the duct. Envelope Method – Free Inlet The Envelope Method is described with DIN 45635-1 and -38, which specifies a hypothetical box shaped measurement surface with several prescribed measurement points. 1 = Air permeable sound screen 2 = Microphone positions for envelope method 3 = Test fan 4 = Measuring duct 5 = Microphone with sampling tube 6 = Anechoic termination 7 = Step less adjustable throttle 1 2 3 4 5 6 7 Lp4 Lp7 psF The sound data of the fan curves are given as “A” weighted sound power levels. A-sound power level RZR The “A” weighted sound power level are identical for fan intake (LWA7) as well as for fan discharge (LWA4). LWA4 = LWA7 + LWrel4(A) ADH / AT / RDH: LWfc7 = LWA7 + LWrel7 LWfc4 = LWA7 + LWrel4 RZR: LWfc7 = LWA4;7 + LWrel7 LWfc4 = LWA4;7 + LWrel4 A-sound power level ADH / AT / RDH The “A” weighted sound power level (see curves) are apply for fan intake (LWA7). The fan discharge sound power level LWA4 is obtained by calculating: The correction value DLWrel4(A) is found with the table (left below) at the corresponding fan curve page (ADH / RDH) by introducing fan speed and flow rate. An approximation of the “A” weighted sound pressure levels LpA7/LpA6 at a distance of 1 m may be obtained by subtracting 7 dB from the relative “A” weighted sound power levels. If should be noted that site acoustics, duct design, reverberation, natural frequencies etc. can all influence noise to a greater or lesser extent. For more accurate calculations to determine noise protection measures, the sound power level in each octave band is of more value: The noise correction data LWrel4 und LWrel7, in function of the fan speed and flow rate, are to be found with the corresponding table on the fan curve page. In some cases the noise level - calculated by this way - may in some cases be higher than expected at the blade passing frequency. N×z fBP =— 60 fs = Blade passing frequency in Hz N = Fan speed in 1/min z = No of blades (see curve pages) 99 Belt Driven Centrifugal Fans / Description Description Sound LWfc6 = LWfc4 + LWer For a free discharge situation i.e. without duct connected the sound level will be lower because of an end reflection. This is specially true for low frequencies. For this case a correction may be applied to LWfc4 of the first 3 octave bands as follows: ADH / AT / RDH / RZR 0160/-0280 0315/-0800 0900/-1600 fc 63 125 250 Hz LWer LWer LWer -14 -9 -4 -9 -4 -1 -4 -2 0 dB dB dB Explosion protection according to ATEX Fans for use in explosive atmospheres must comply with EC Directive 94/9/EG (ATEX 95). Equipment in Group II (all applications except mining) is categorised in accordance with the required degree of safety for designated use in equipment categories 1, 2 and 3. Depending on suitability, a distinction is in addition made between G (gas, vapours) and D (dust). Harmonised European standards and national guidelines must be observed. Equipment in class 2 and 3 is not subject to compulsory specifications nor to type testing. The manufacturer declares conformity with the EC directive. For the standard designs of our fans, the following ignition sources are essentially to be considered: A Hot surfaces, e.g. due to heat of friction or seizure of a bearing or due to blockage of an impeller A Rubbing-, grinding- or beating sparks, e.g. as a result of contact of the impeller with stationary components A Sparks resulting from discharge of electrostatically loaded, non-conducting omponents, e.g. of plasticpanels, surfaces with strong layer thickness. Preconditions for operating: A In the proximity of the motor, the temperature limits -20 °C and +40 °C must not be exceeded. A The temperature limits of -20 °C und +60 °C for the flow medium must not be exceeded. If the temperature of the flow medium should exceed +60 °C on the pressure side, then the fan must be switched off! A The fans may only be employed with a horizontal shaft. A The fans are to be protected against the falling-in or sucking-in of foreign objects. Protection guards must be ordered separately as an accessories. A On the machine plate the max. permitted fan speed is indicated. A Fans for operation in ex-hazardous areas are marked as such on the machine plate and they are accompanied by an EU conformity declaration and with operation and maintenance instructions. The operation and maintenance instructions have strictly to be observed. The conformity is always related to the fan system supplied. If the fan is completed with motor and belt drive by the customer the conformity of this fan set has to be declared at new. Fans of the series ADH / AT / RDH in ATEX-Execution on request. 100 Belt Driven Centrifugal Fans / Description Description Operating limits RZR ATEX Permissible fan speed RZR 1/min Permissible shaft power Permissible nominal motor power kW kW 11-0200-2G 12-0200-2G 19-0200-2G 11-0225-2G 12-0225-2G 19-0225-2G 11-0250-2G 12-0250-2G 19-0250-2G 11-0280-2G 12-0280-2G 19-0280-2G 11-0315-2G 12-0315-2G 19-0315-2G 11-0355-2G 12-0355-2G 19-0355-2G 11-0400-2G 12-0400-2G 13-0400-2G 18-0400-2G 11-0450-2G 12-0450-2G 13-0450-2G 18-0450-2G 11-0500-2G 12-0500-2G 13-0500-2G 18-0500-2G 11-0560-2G 12-0560-2G 13-0560-2G 18-0560-2G 11-0630-2G 12-0630-2G 13-0630-2G 18-0630-2G 11-0710-2G 12-0710-2G 13-0710-2G 18-0710-2G 11-0800-2G 18-0800-2G 13-0800-2G 11-0900-2G 18-0900-2G 13-0900-2G 11-0100-2G 18-1000-2G 13-1000-2G 13-1120-2G 13-1250-2G 13-1400-2G 13-1600-2G 6513 6513 6513 5774 5774 5774 4620 4620 5076 4582 4582 4582 3793 3793 4113 3110 3110 3555 2552 2552 3145 2913 2111 2111 2922 2410 1752 1752 2534 2000 1660 1660 2163 1660 1367 1367 2055 1367 1128 1128 1825 1128 927 927 1474 767 767 1339 650 650 1217 1026 957 870 748 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 6.5 6.5 9.7 6.5 6.5 9.7 6.5 6.5 9.7 6.5 6.5 16.4 9.7 6.5 6.5 21.3 9.7 6.5 6.5 21.3 9.7 9.7 9.7 26.6 9.7 9.7 9.7 32.8 9.7 9.7 9.7 40.9 9.7 9.7 9.7 40.9 9.7 9.7 68 9.7 9.7 68 83.6 122 145 181 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 7.5 7.5 11 7.5 7.5 11 7.5 7.5 11 7.5 7.5 18.5 11 7.5 7.5 24 11 7.5 7.5 24 11 11 11 30 11 11 11 37 11 11 11 45 11 11 11 45 11 11 75 11 11 75 92 135 160 200 101 Belt Driven Centrifugal Fans / Description Description Symbol / Unit / Definition The following symbols are used in this catalogue: A-A 102 - The following symbols are used in this catalogue: Operational range (free discharge) PN kW Motor power (nominal) A2mm² Fan outlet area psF Pa Fan static pressure (free discharge) b mm Deflection of belt under test force gp Pa Differential pressure Dr mm Impeller diameter gp0 Pa Pressure difference at the inlet measuring device fBP Hz Blade passing frequency gpDü Pa Pressure difference at the inlet cone fc Hz Octave centre frequency qv Volume flow rate fp - Motor size correction factor qVopt m³/h Volume flow at optimum efficiency Fp N Test force RW J/kg×K Specific gas constant fpd - Dynamic pressure correction factor (free discharge) t °C Temperature of flow medium fh - Correction at actual efficiency ta °C Temperature of discharge air in test chamber J kgm² Moment of inertia tA s Acceleration time K m²s/h Calibration factor for volumeter t1 °C Air temperature LT mm Centre distance Θ K Thermodynamic temperature at fan inlet LMg mm Measuring marks before tensioning (flat belts) u m/s Tip speed LMu mm Measuring marks after tensioning (flat belts) v2 m/s Outlet velocity LpA4 dB A weighted sound pressure level (discharge) vm2 m/s Average fluid velocity at discharge LpA7 dB A weighted sound pressure level (inlet) X mm Pulley position on shaft extension relative to bearing LWA dB A weighted sound power level z - No. of blades LWA4 dB In duct sound power level (discharge) e* mm Stretching value of flat belt LWA7 dB Casing and free inlet sound power level ha % Total efficiency at max speed LWfc4 dB Discharge sound power in the octave bands hr % Impeller efficiency LWfc7 dB Inlet sound power in the octave band hs % Fan total efficiency at max speed LWrel4 dB Relative sound power (discharge) rkg/m² Air density LWrel7 dB Relative sound Power (inlet) r1 Air density at fan inlet L10h h Nominal bearing life m kg Mass N 1/min Fan speed Nmax 1/min Maximum fan speed pa Pa Atmospheric pressure Pa kW Absorbed fan power Pb kW Bearing power losses pd2 Pa fan dynamic pressure at discharge pF Pa Total fan pressure m³/h kg/m² Belt Driven Centrifugal Fans / Description / Notes Notes Quality management system DIN EN ISO 9001 Nicotra Gebhardt quality is the result of a continuous company policy intended to guarantee that our product properties and features are clearly superior to comparable products. This already established company maxim led in April 1985 to the auditing and certification of the existing quality management system. In the following years it was updated to match the changing international and European standards. Modern production processes, monitored by our quality management system, guarantee a high repeat accuracy in production. This ongoing high standard of quality permits the establishing of the performance data in classes of accuracy in accordance with DIN 24166. The narrow tolerances ensure a high level of data reliability for our products. Machine Safety The fans contained in this catalogue are not machines in the sense of the EC Machine Directive. They are delivered with a manufacturer "Declaration of incorporation". The assessment of the dangers associated with the fan and necessary safety measures are based on the VDMA Unit sheet 24167: Fans; Safety requirements. The operating instructions give which safety measures are still necessary on assembly to ensure that the fans comply with the Machine Directive 2006/42/EC. Catalogue data We reserve the right to change any measurements and technical data in this catalogue in accordance with further development of our products. All information valid at the time of printing. 103 nicotra-gebhardt.com AUSTRALIA 65 Yale Drive, Epping, VIC 3076 Phone +61 3 9017 5333 Fax +61 3 8401 3969 E-mail info@nicotra.com.au BELGIUM Haeghensgoed, 13 - 00/01 9270 Laarne Phone +32 (0)9-336-00-01 Fax +32 (0)9-336-00-05 E-mail info.nicotra@nicotra.be CHINA 88 Tai‘An Road, XinQiao, ShiJi, Panyu Guangzhou 511450 PR CHINA Phone +86 (0)20-2293 5700 Fax +86 (0)20-2293 5701 E-mail sales@nicotra-china.com FRANCE Leader's Park Bat A1 3 chemin des Cytises 69340 Francheville Phone +33 (0)4 72 79 01 20 Fax +33 (0)4 72 79 01 21 E-mail g.cauche@nicotra-gebhardt.com GERMANY Gebhardtstraße 19-25 74638 Waldenburg Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail info@nicotra-gebhardt.com GREAT BRITAIN Unit D, Rail Mill Way Parkgate Business Park Rotherham South Yorkshire S62 6JQ Phone +044 01709-780760 Fax +044 01709-780762 E-mail sales@nicotra.co.uk INDIA Plot no 28F & 29, Sector-31,Kasna, Greater Noida-201 308 U.P (India) Phone +91 120 4783400 Phone +91 22 65702056 (Mumbai) Phone +91 80 25727830 (Bangalore) E-mail info@nicotraindia.com ITALY Via Modena, 18 24040 Zingonia (BG) Phone +39 035 873 111 Fax +39 035 884 319 E-mail info@nicotra-gebhardt.com 104 MALAYSIA Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing 43300 Seri Kembangan Selangor Phone +603 8961-2588 Fax +603 8961-8337 E-mail info_malaysia@nicotra-gebhardt.com SPAIN Ctra. Alcalá-Villar del Olmo, Km. 2,830 28810 Villalbilla-Madrid Phone +34 918-846110 Fax +34 918-859450 E-mail info@nicotra.es SINGAPORE 3, Science Park Drive, # 04-07, The Franklin Singapore Science Park 1 Singapore 118223 Phone +65 6265 1522 Fax +65 6265 2400 E-mail info_singapore@nicotra-gebhardt.com Nicotra Gebhardt Germany Nicotra Gebhardt Italy Nicotra Gebhardt GmbH Gebhardtstraße 19-25 74638 Waldenburg Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-Mail info@nicotra-gebhardt.com Nicotra Gebhardt S.p.A Via Modena, 18 24040 Zingonia (BG) Italy Phone +39 035 873 111 Fax +39 035 884 319 E-Mail info@nicotra-gebhardt.com SWEDEN Kraketorpsgatan 30 43153 Mölndal Phone 0046 101-302600 Fax 0046 31-878590 E-mail info.se@nicotra-gebhardt.com THAILAND 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 10150 Phone +662 476-1823-6 Fax +662 476-1827 E-mail sales@nicotra.co.th UNITED STATES PO BOX 900921 Sandy, Utah 84090 Phone 001(801) 733-0248 Fax 001(801) 315-9400 Mobile 001(801) 682 0898 E-mail mike.sehgal@gebhardtfans.com http://www.gebhardtfans.com/ nicotra-gebhardt.com EN-TD3-CFB-2.5 – PDF1-August2013 Nicotra Gebhardt worldwide