No Ice, Machine Off CM Cubed Service Diagnosis - Main Chart Remove Front Panel, Check if Controller Has Any Lights On. Any Lights On? No Check power to unit, see Power Page Yes See Chart W Yes See Chart R Yes See Chart B Yes See Chart O Yes See Chart C Yes See Chart F Yes Check which light is on. Water and Off? No Refrigeration & Off? No Bin Full? No Off? No Clean? No Freeze or Harvest? Chart W From Main Chart Water Diagnostic Light Blinks Once and Repeats Yes Check water pump, see Pump Page Yes Check for slow or no water fill, see Water Page Yes Check for water inlet valve leak thru, see Water Page No Water Diagnositc Light Blinks Twice and Repeats No Water Diagnostic Light is On without blinking Machine Operating No Water AND Refrigeration Lights are On without blinking Yes Thermistor harness may be unplugged Harness plugged in? Yes Replace Thermistor Set No Plug In Chart R From Main Chart Refrigeration Diagnostic Light blinks once and repeats Yes Check for cause of slow harvest, see Harvest Page Yes Check for cause of no ice being harvested or sensed. See Harvest Page Yes Check for cause of high discharge temperature No Refrigeration Diagnostic Light blinks twice and repeats No Refrigeration Diagnositic Light blinks three times and repeats No Refrigeration Diagnostic Light is on without blinking Yes Check for cause of long freeze cycle, see Freeze Page Chart B From Main Chart Check for ice between photo-eyes Ice in between? Yes Remove ice, machine will start in less than 4 minutes Yes Clean photo-eyes with ice machine cleaner No Line up eyes No Dry the photo-eyes No Scale on eyes? No Eyes in alignment> Yes Eyes dry? Yes Replace eyes Chart F From Main Chart Machine should be operating, check loads for voltage Power to contactor coil? Yes Coil OK? No No Power to water pump? Replace contactor Yes Push Off, then Freeze Machine starts? No Replace Controller No Power to fan motor? Yes No In harvest? Yes Normal No Harness OK? No Replace harness Yes From Main Chart Chart O Push freeze, ask user why unit switched off Machine switched off by user Chart C From Main Chart In Clean cycle Is Clean light on but blinking? Yes Push Clean No Push Freeze From Main Chart Power Page Power No Restore Power No Replace transformer Yes Check Transformer Transformer OK? Yes Machine operating Check for voltage to controller Voltage? No Check harness, clean pins Yes Check for lights Lights? No Replace controller Yes Pump Page From Chart W Water Diagnostic Light Blinks Once and Repeats Yes Check water pump Pump OK? No Check voltage to pump Voltage OK? No Check harness and pins Yes Replace pump Water Page From Chart W Water Diagnostic Light Blinks Twice and Repeats Yes Check for slow or no water fill Water valve OK? Is valve screen dirty? Yes Yes Clean screen No No Check for power to valve Water to unit? Water filters restricted? Yes No No Yes Restore water supply Replace filter cartridges Power? Water diagnostic light is ON without blinking? Yes Valve working? No Replace valve No Yes No Clean harness, check pins Yes Machine Operating Check for water inlet valve leak thru Yes Voltage at pins but not valve? Yes Water valve leaking thru? Yes Voltage to coil? No No No Replace valve Reset controller Replace controller Replace harness Harvest Page From Chart R Refrigeration Diagnostic Light blinks once and repeats Yes Check for cause of slow harvest Hot gas valve opens fully? Ice path restricted? Yes Yes No No No Refrigerant charge correct? No Remove restriction No Lime scale on evaporators? Locate leak, repair and rechage Check voltage to hot gas valve Yes Clean water system Refrigeration Diagnostic light blinks twice and repeats Reset controller Voltage? Yes No Replace hot gas valve Check harness and pins Check for cause of no ice being harvested or sensed Can photo-eyes see ice> No Pins and harness OK? Clean photo-eye emitter and receiver Yes Check harness Replace controller Unplug harness from #4, short pins together Bin full light blinks? Yes Replace photo eyes No No Clean pins or replace harness Machine operates From Chart R Freeze Page Refrigeration Diagnostic Light is ON without blinking Yes Check for cause of long freeze cycle If water cooled check for water having been shut off No Voltage to motor? Fan motor turns? Yes Yes Check condenser filter or fins for dirt Replace Fan Motor No Condenser dirty? Water shut off? Yes Clean condenser Check harness Yes Machine Operates Reset controller Harness OK? No Replace harness Yes Check/Clean pins Power to Fan? No Replace controller Yes