FT50-CS/SWA FT55-CS/SWA SERIES FIRSTRONIC SWA MULTIPAIR OVERALL FOIL SCREENED SPVC TINNED INSTRUMENTATION CABLES 110V RMS 90°C APPLICATIONS: Hazardous Areas This Steel Wire Armour cable is suitable for use for instrumentation in oil and gas industries, mine sites and other harsh environments. BUS Systems Extra low capacitance cable suitable for RS485, RS422 POS, building and home BUS automation systems. ELV Signal and Controls E.L.V. power control or signal/instrumentation cables on machines, conveying equipment or similar industrial applications. Marine Tinned Copper conductors for use in marine applications. CONSTRUCTION: Conductor Annealed wires of tinned stranded electrolytic copper Insulation Special SPVC V90HT (available in LSHF on request) Screening Collective shield of Aluminum/Polyester foil complete with Tinned copper drain wire Armour Steel Wire Armour Sheath Special SPVC V90 (available in LSHF on request) CHARACTERISTICS: Temperature Range Fixed -20°C to 90°C Rated Voltage 110VRMS/150VDC Minimum Bending Radius 10 x cable diameter Sheath Colour Black Standard Core Colours Each Pair – 1 x white and 1 x black conductor, with numbered cores Maximum Conductor Temperature 90°C Relevant Standards AS/NZS 1125, AS/NZS 3808, IEC60332-1, IEC60332-3 CAT A, C Directive 2006/95/EC and RoHS Compliant. PRODUCT FEATURES: Steel Wire Armoured for hazardous conditions UV Stabilised Heat, oil and chemical resistant (refer to chemical chart page 264) Extremely Pliable PVC Sheath Flame retardant Reduced flame propogation 0.5mm2 1.5mm2 Property DC Conductor Resistance @ 20°C Max. Capacitance Cond. To Cond. (screened) Max. Capacitance Cond. To Scr. (screened) Max. Capacitance Cond. To Cond. (unscreened) Cross talk attenuation between pairs @ 1kHz (screened) Cross talk attenuation between pairs @ 1kHz (unscreened) Characteristic impedance @ 1kHz (screened) Characteristic impedance @ 1kHz (unscreened) Inductance @ 1kHz L/R ratio @ 1kHz Insulation Resistance @ 20°C Value Units Value Units 38.4 145 240 82 >125 >90 300 380 1.00 13.7 140 Ω/km pF/m pF/m pF/m dB/100m dB/100m Ω Ω mH/km μH/Ω MΩ.km 13.6 200 300 110 >125 >90 150 200 0.95 36.5 140 Ω/km pF/m pF/m pF/m dB/100m dB/100m Ω Ω mH/km μH/Ω MΩ.km Firstflex has taken every precaution to ensure accurate information in this catalogue but accept no liability for any errors or omissions. Firstflex reserves the right to modify specifications at any time. 140 | P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz Continued Over Page FT50/55-CS/SWA SERIES ...Continued Part Number Number of Cores x Size Nearest AWG mm2 Overall Diameter over bedding Overall Diameter over Armour No. wires x mm2 mm mm mm2 Kg/Km Approximate Stranding Approximate Approximate Overall Weight Diameter FT5001CS SWA 1 pair 0.5 20 7/0.30 5.6 7.4 10.4 225 FT5002CS SWA 2 pair 0.5 20 7/0.30 8.6 10.4 12.5 298 FT5004CS SWA FT5006CS SWA FT5008CS SWA FT5010CS SWA FT5012CS SWA FT5016CS SWA FT5020CS SWA FT5024CS SWA FT5036CS SWA FT5102ES SWA FT5502CS SWA FT5504CS SWA FT5506CS SWA FT5508CS SWA FT5510CS SWA FT5512CS SWA FT5516CS SWA FT5520CS SWA FT5524CS SWA FT5536CS SWA 4 pair 0.5 6 pair 0.5 8 pair 0.5 10 pair 0.5 12 pair 0.5 16 pair 0.5 20 pair 0.5 24 pair 0.5 36 pair 0.5 1 pair 1.5 2 pair 1.5 4 pair 1.5 6 pair 1.5 8 pair 1.5 10 pair 1.5 12 pair 1.5 16 pair 1.5 20 pair 1.5 24 pair 1.5 36 pair 1.5 20 20 20 20 20 20 20 20 20 15 15 15 15 15 15 15 15 15 15 15 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.30 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 7/0.50 9.8 10.6 11.4 13.3 13.7 15.4 16.6 18.9 21.8 6.7 10.4 11.9 13.2 14.2 16.7 17.3 19.4 21.3 24.3 27.9 11.6 12.4 13.2 15.1 15.5 17.2 19.1 21.4 24.3 8.5 12.2 13.7 15.0 16.0 19.2 19.8 21.9 23.8 26.8 31.1 14.5 15.5 16.7 18.7 19.1 21.3 23.2 25.6 28.8 11.5 14.3 17.8 18.3 19.2 22.5 23.8 26.0 28.1 32.1 35.0 358 440 507 592 632 763 1006 1150 1449 278 390 498 651 749 1043 1150 1370 1591 1856 2645 Part Number FT5001CS SWA FT5002CS SWA FT5004CS SWA FT5006CS SWA FT5008CS SWA FT5010CS SWA FT5012CS SWA FT5016CS SWA FT5020CS SWA FT5024CS SWA FT5036CS SWA FT5102ES SWA FT5502CS SWA FT5504CS SWA FT5506CS SWA FT5508CS SWA FT5510CS SWA FT5512CS SWA FT5516CS SWA FT5520CS SWA FT5524CS SWA FT5536CS SWA Olex Cables Product Code General Cables Product Code Maser Communications Product Code IEC183AA002 IEG183AA004 IEG183AA006 IEG183AA008 IEG183AA010 IEG183AA012 IEG183AA016 IEG183AA020 IEG183AA024 IEG183AA036 IEF 184AA001 IEG 184AA002 IEG 184AA004 IEG 184AA008 IEG 184AA012 IEG 184AA016 IEG 184AA024 IEG 184AA036 B5002CS SWA B5004CS SWA B5006CS SWA B5008CS SWA B5010CS SWA B5012CS SWA B5016CS SWA B5020CS SWA B5024CS SWA B5036CS SWA B5102ES SWA B5502CS SWA B5504CS SWA B5506CS SWA B5508CS SWA B5512CS SWA B5516CS SWA - B1033B SWA B3016B SWA B1055B SWA B5006B SWA B1057B SWA B5010B SWA B1058B SWA B1059B SWA B5020B SWA B1060B SWA B1061B SWA B1030B SWA B3043B SWA B1484B SWA B1485B SWA B1486B SWA B3050B SWA B1489B SWA B1490B SWA Gland Size GMCW16 or GMCW20SS GMCW16 or GMCW20SS GMCW20S GMCW20S GMCW20 GMCW25 GMCW25 GMCW25 GMCW25 GMCW25 GMCW32 GMCW20S GMCW20S GMCW20 GMCW20 GMCW25 GMCW25 GMCW25 GMCW32 GMCW32 GMCW40 GMCW50 Firstflex has taken every precaution to ensure accurate information in this catalogue but accept no liability for any errors or omissions. Firstflex reserves the right to modify specifications at any time. | P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz 141