Print Specifications

advertisement
FT50-CS/SWA
FT55-CS/SWA
SERIES
FIRSTRONIC SWA MULTIPAIR OVERALL FOIL
SCREENED SPVC TINNED INSTRUMENTATION CABLES
110V RMS 90°C
APPLICATIONS:
Hazardous Areas This Steel Wire Armour cable is suitable for use for instrumentation in oil and gas industries, mine sites and other harsh
environments.
BUS Systems Extra low capacitance cable suitable for RS485, RS422 POS, building and home BUS automation systems.
ELV Signal and Controls E.L.V. power control or signal/instrumentation cables on machines, conveying equipment or similar industrial applications.
Marine Tinned Copper conductors for use in marine applications.
CONSTRUCTION:
Conductor Annealed wires of tinned stranded electrolytic copper
Insulation Special SPVC V90HT (available in LSHF on request)
Screening Collective shield of Aluminum/Polyester foil complete with Tinned copper drain wire
Armour Steel Wire Armour
Sheath Special SPVC V90 (available in LSHF on request)
CHARACTERISTICS:
Temperature Range Fixed -20°C to 90°C
Rated Voltage 110VRMS/150VDC
Minimum Bending Radius 10 x cable diameter
Sheath Colour Black
Standard Core Colours Each Pair – 1 x white and 1 x black conductor, with numbered cores
Maximum Conductor Temperature 90°C
Relevant Standards AS/NZS 1125, AS/NZS 3808, IEC60332-1, IEC60332-3 CAT A, C Directive 2006/95/EC and RoHS Compliant.
PRODUCT FEATURES:
 Steel Wire Armoured for hazardous conditions
 UV Stabilised
 Heat, oil and chemical resistant (refer to chemical chart page 264)
 Extremely Pliable PVC Sheath
 Flame retardant
 Reduced flame propogation
0.5mm2
1.5mm2
Property
DC Conductor Resistance @ 20°C
Max. Capacitance Cond. To Cond. (screened)
Max. Capacitance Cond. To Scr. (screened)
Max. Capacitance Cond. To Cond. (unscreened)
Cross talk attenuation between pairs @ 1kHz (screened)
Cross talk attenuation between pairs @ 1kHz (unscreened)
Characteristic impedance @ 1kHz (screened)
Characteristic impedance @ 1kHz (unscreened)
Inductance @ 1kHz
L/R ratio @ 1kHz
Insulation Resistance @ 20°C
Value
Units
Value
Units
38.4
145
240
82
>125
>90
300
380
1.00
13.7
140
Ω/km
pF/m
pF/m
pF/m
dB/100m
dB/100m
Ω
Ω
mH/km
μH/Ω
MΩ.km
13.6
200
300
110
>125
>90
150
200
0.95
36.5
140
Ω/km
pF/m
pF/m
pF/m
dB/100m
dB/100m
Ω
Ω
mH/km
μH/Ω
MΩ.km
Firstflex has taken every precaution to ensure accurate information in this catalogue but accept no liability for any errors or omissions. Firstflex reserves the right to modify specifications at any time.
140
| P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz

Continued Over Page

FT50/55-CS/SWA SERIES ...Continued
Part Number
Number of
Cores
x
Size
Nearest
AWG
mm2
Overall
Diameter
over
bedding
Overall
Diameter
over
Armour
No. wires
x mm2
mm
mm
mm2
Kg/Km
Approximate
Stranding
Approximate Approximate
Overall
Weight
Diameter
FT5001CS SWA
1 pair 0.5
20
7/0.30
5.6
7.4
10.4
225
FT5002CS SWA
2 pair 0.5
20
7/0.30
8.6
10.4
12.5
298
FT5004CS SWA
FT5006CS SWA
FT5008CS SWA
FT5010CS SWA
FT5012CS SWA
FT5016CS SWA
FT5020CS SWA
FT5024CS SWA
FT5036CS SWA
FT5102ES SWA
FT5502CS SWA
FT5504CS SWA
FT5506CS SWA
FT5508CS SWA
FT5510CS SWA
FT5512CS SWA
FT5516CS SWA
FT5520CS SWA
FT5524CS SWA
FT5536CS SWA
4 pair 0.5
6 pair 0.5
8 pair 0.5
10 pair 0.5
12 pair 0.5
16 pair 0.5
20 pair 0.5
24 pair 0.5
36 pair 0.5
1 pair 1.5
2 pair 1.5
4 pair 1.5
6 pair 1.5
8 pair 1.5
10 pair 1.5
12 pair 1.5
16 pair 1.5
20 pair 1.5
24 pair 1.5
36 pair 1.5
20
20
20
20
20
20
20
20
20
15
15
15
15
15
15
15
15
15
15
15
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.30
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
7/0.50
9.8
10.6
11.4
13.3
13.7
15.4
16.6
18.9
21.8
6.7
10.4
11.9
13.2
14.2
16.7
17.3
19.4
21.3
24.3
27.9
11.6
12.4
13.2
15.1
15.5
17.2
19.1
21.4
24.3
8.5
12.2
13.7
15.0
16.0
19.2
19.8
21.9
23.8
26.8
31.1
14.5
15.5
16.7
18.7
19.1
21.3
23.2
25.6
28.8
11.5
14.3
17.8
18.3
19.2
22.5
23.8
26.0
28.1
32.1
35.0
358
440
507
592
632
763
1006
1150
1449
278
390
498
651
749
1043
1150
1370
1591
1856
2645
Part Number
FT5001CS SWA
FT5002CS SWA
FT5004CS SWA
FT5006CS SWA
FT5008CS SWA
FT5010CS SWA
FT5012CS SWA
FT5016CS SWA
FT5020CS SWA
FT5024CS SWA
FT5036CS SWA
FT5102ES SWA
FT5502CS SWA
FT5504CS SWA
FT5506CS SWA
FT5508CS SWA
FT5510CS SWA
FT5512CS SWA
FT5516CS SWA
FT5520CS SWA
FT5524CS SWA
FT5536CS SWA
Olex Cables
Product Code
General Cables
Product Code
Maser
Communications
Product Code
IEC183AA002
IEG183AA004
IEG183AA006
IEG183AA008
IEG183AA010
IEG183AA012
IEG183AA016
IEG183AA020
IEG183AA024
IEG183AA036
IEF 184AA001
IEG 184AA002
IEG 184AA004
IEG 184AA008
IEG 184AA012
IEG 184AA016
IEG 184AA024
IEG 184AA036
B5002CS SWA
B5004CS SWA
B5006CS SWA
B5008CS SWA
B5010CS SWA
B5012CS SWA
B5016CS SWA
B5020CS SWA
B5024CS SWA
B5036CS SWA
B5102ES SWA
B5502CS SWA
B5504CS SWA
B5506CS SWA
B5508CS SWA
B5512CS SWA
B5516CS SWA
-
B1033B SWA
B3016B SWA
B1055B SWA
B5006B SWA
B1057B SWA
B5010B SWA
B1058B SWA
B1059B SWA
B5020B SWA
B1060B SWA
B1061B SWA
B1030B SWA
B3043B SWA
B1484B SWA
B1485B SWA
B1486B SWA
B3050B SWA
B1489B SWA
B1490B SWA
Gland
Size
GMCW16 or
GMCW20SS
GMCW16 or
GMCW20SS
GMCW20S
GMCW20S
GMCW20
GMCW25
GMCW25
GMCW25
GMCW25
GMCW25
GMCW32
GMCW20S
GMCW20S
GMCW20
GMCW20
GMCW25
GMCW25
GMCW25
GMCW32
GMCW32
GMCW40
GMCW50
Firstflex has taken every precaution to ensure accurate information in this catalogue but accept no liability for any errors or omissions. Firstflex reserves the right to modify specifications at any time.
| P (09) 264 1000 | F (09) 264 1001 | E sales@firstflex.co.nz | W www.firstflex.co.nz
141
Download