PS62 – OEM Subminiature Pressure Switch 15 to 600 psi (1 to 41 bar) Exceptional Size-to-Pressure-Range Ratio Adjustable or Factory Set Minimal Set Point Change at Low Temperature Extremes These compact pressure switches are designed for medium pressure OEM applications. They offer all the performance of our proven PS61 model with the low temperature capability of Kapton®. Dimensions Specifications Operating Temperature Switch* Repeatability Wetted Parts Housing Diaphragm O-Ring Electrical Termination Deadband Proof Pressure Burst Pressure Approvals Weight, Approximate -40°F to +230°F (-40°C to +110°C) 100 VA Max. See Table 1 Zinc-Plated Steel (optional 316L Stainless Steel) Kapton® (polyimide) Nitrile (other materials available) Exposed Terminals IP00; IP option IP66 See Table 1 3000 psi (207 bar) 6000 psi (414 bar) CE (limits switch voltage to 42 VDC) Steel: 0.14 lbs. (0.06 kg) 0.54˝ (14) 15/16˝ AF IP66 CAP 1.10˝ (28) 1.68˝ (43) *Gold contacts (option G) may be required for less than 12 VDC and 20 mA. PRESSURE SWITCHES I-13 ADJUSTMENT SCREW Visit www.GemsSensors.com for most current information. 0.36˝ (9) 1.93˝ (49) SUBMINIATURE How To Order Use the Bold characters from the chart below to construct a product code. Please reference Notes. PS62-10 -4MNZ-A-SP -XX -XXXX 1 1 Pressure Range Code Insert Pressure Range Code from Table 1, below. 2 Pressure Fitting1 12L14 Zinc-Plated Steel -2MNZ=1/8˝ NPTM 12L14 -4MNZ=1/4˝ NPTM 12L14 -2MGZ=1/8˝ BSPM 12L14 (G type) -4MGZ=1/4˝ BSPM 12L14 (G type) -4MSZ=7/16˝-20 SAE Male -6MSZ=9/16˝-18 SAE Male -M10Z=M10 x 1.0, Straight -M14Z=M14 x 1.5, Straight 316L Stainless Steel -2MNS=1/8˝ NPTM -4MNS=1/4˝ NPTM -2MGS=1/8˝ BSPM (G type) -4MGS=1/4˝ BSPM (G type) -4MSS=7/16˝-20 SAE Male -6MSS=9/16˝-18 SAE Male 2 3 4 5 5Options -G=Gold Contacts (for loads less than 12 mA @ 12 VDC) -IP=Ingress Protection4 -IPA=Removable Silicone Seal for Set Point Adjustment5 -R=Restrictor (low damping coefficient) Brass -SR=Spiral Restrictor (high damping coefficient) 12L14 Steel w/Black Oxide Finish6 -OF=Oil Free Cleaned (requires SS housing) -RB=Rubber Boot (shipped loose) -WF=Weather Pack Connector, Female -WM=Weather Pack Connector, Male -DE=Deutsch Connector, Male, DT04 Series 6 Fixed Set Point (optional) A.Specify set point -FS (in PSI or BAR, see example)7 B.Set Point Actuation R on Rising Pressure F on Falling Pressure Example: -FS3BARF for 3 BAR Falling or -FS60PSIR for 60 PSI Rising 3Circuit -A =SPST/N.O. -B=SPST/N.C. 6 Notes: 1. Other fittings available. Consult factory. 2. 18˝ is standard. Specify lead length in inches (max. 48˝). e.g. -FL18 or -FLS30. 3. 36˝ is minimum. Specify cable length in inches. e.g. -CAB36 or -CAB120. 4. Ingress Protection is available only with -FL, -FLS or -CAB Electrical Termination choices. 5. IPA protection is available only with -FL or -FLS. 6. -SR will result in wider deadbands and lower response time. 7. Set Point must be within Pressure Range selected in Step 1. 4 Electrical Termination -SP=Spade Terminals (standard) -TS=Terminal Screws -FLXX=Flying Leads2 -FLSXX=Flying Leads w/PVC Shrink Tubing2 -CABXX=18 AWG PVC Cable3 Pressure Range Code Pressure Range Accuracy* 10 15-60 psi (1-4 bar) ±1.5 psi (0.10 bar) +4% of setting 3 psi (0.21 bar) +6% of setting 20 40-150 psi (3-10 bar) ±2.5 psi (0.17 bar) +4% of setting 5 psig (0.34 bar) +7% of setting 30 75-275 psi (5.2-18.9 bar) ±3.75 psi (0.26 bar) +4% of setting 7 psig (0.48 bar) +9% of setting 40 150-600 psi (10.3-41.4 bar) ±5 psi (0.34 bar) +4% of setting 10 psi (0.69 bar) +11% of setting *Accuracy and set point of units may change due to the effects of temperature. **In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details. Visit www.GemsSensors.com for most current information. Average Deadband** PRESSURE SWITCHES Table 1 — Pressure Range Codes I-14