MOUNTING INSTRUCTIONS
NILE RADAR MOUNTING FLANGE
Item # Nile FL
Thank you for purchasing the new WaterLOG Nile radar level sensor! This is the mounting instructions
for the Nile Radar Mounting Flange. For more detailed information regarding the Nile radar sensor
visit www.waterlog.com/nile. Please contact us at any time with your comments and feedback about
our products and services. We truly value your input.
1
What’s In The Box
Please contact YSI customer service immediately if any
expected items listed are not in the box.
Standard Items
Quantity
Nile Flange Plates (Symmetrical)
2
8-32 x 5/16 Screw
4
6-32 Set Screw
2
Hex Key
1
M4 x 18MM Screw
1
Nile Radar Sensor Mounting Flange Kit
2
3
Remove Bolt
Remove the hex bolt and radar cone retaining clip
from radar housing as shown.
Secure Screws
2
3
Mate the two symmetrical flange plates around the
narrow neck of the radar horn, and secure with four
8-32 machine screws.
Remove Hex Bolt and Retaining Clip,
Assemble Flange
1
4
Slide Flange
Slide assembled Flange over the base of the Radar
cone.
4
5
5,6
Align Mount
Align one mounting hole of the assembled Flange
with the threaded boss in the Radar housing.
Secure Flange
6
Insert M4 Screw
7
Tighten Flange To Collar
8
Insert M4 Screw into housing boss as shown and
tighten to “finger tight”.
Insert set screw into Flange (opposite of Radar
housing screw boss) as shown and tighten using
supplied hex key.
Insert Set Screw
Final Tighten
After tightening set screw onto the Radar collar,
final tighten the M4 screw into the threaded boss
until secure.
©2015 WaterLOG+1.435.753.2212sales@waterlog.com