Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component Grounded Metal Equipment Plate 15 kV or 25 kV Separable Insulated Connector (elbow) Equipment Connection Bus Bar or Other Component Power Cable Power Cable For 15-kV and 25-kV Connectors (Elbows) Elliott “A” Series (clamp-in) apparatus bushings are used to construct air-insulated equipment that connects to the utility’s underground shielded cable system with IEEE Standard separable insulated connectors (i.e. elbows). Integral shielding prevents “edge-of-hole” corona discharge. The live side of the bushing is provided with unique square-edge skirts to resist flashover when contaminated and wet. The large diameter live end terminal pad (with female threads) provides for direct contact of current-carrying parts and eliminates exposed sharp threads, which could induce destructive corona discharge. In addition to IEEE Standard 386 design tests, Elliott bushings are design tested for thermal cycle withstand from +200° to -200° F to assure long field life. Every bushing is production tested “in-air” mounted in a grounded steel plate with an insulated protective plug (or cap) installed on the interface to accurately simulate operating conditions. ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation Mechanical and thermal toughness Shatter-free arc flashover performance Oil resistant Elliott Design Provides: Precision molded interfaces per IEEE Standard 386 Integral shielding to prevent destructive corona discharge Square-edge skirts resist contamination - wet or dry Generous dry arcing (strike) distance Large diameter live end terminal pad with female threads for direct contact of current-carrying parts and improved corona performance Thermal cycle withstand from +200° to -200° F for long life High Strength - field proven performance since 1975 Ratings and Dimensions of Bushing Wells & Bushings Voltage Class kV Continuous Current Amps 1101-225A2 Bushing Well 25 1201-625A2 Bushing 1201-625A2F Bushing Catalog Number Withstand Test Voltage Kilovolts Minimum Leakage Inches Minimum Strike Inches Impulse 1.2 x 50 One Min. Dry 10 Sec. Dew 200 125 40 26 17 8.5 25 600 125 40 26 21 10 25 600 125 40 26 21 10 Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 1509 Hamilton Road Phone 318-746-3296 RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp RTE® Clamp Ring #1991-CRAR Clamp Ring Adapter and Bushing Well to replace RTE® 8.3 kV Safebreak Bushing (Page 7) Page 2 Existing RTE® Mounting Hole 200 Amp 15 kV or 25 kV Elbow and Insert 2015 0.375"–16 Bolt Bus Bar or Other Component #1900-CR4S Clamp Ring 200 Amp Bushing Well (Page 3) Small "A" Series Mounting Hole #1900-CR4S Clamp Ring 600 Amp Bushing (Page 4) Large "A" Series Mounting Hole 0.625"–11 Bolt Bus Bar or Other Component #1902-CR4-A2F Clamp Ring 600 Amp Bushing Special Flange (Page 5) A2F Special Mounting Hole 600 or 1250 Amp 15 kV or 25 kV Elbow Elliott “A2” Bushings are advanced design clamp-in bushings typically used to construct air-insulated pad-mounted switchgear. Elliott “A2” bushings fit older-style equipment constructed with clamp-in bushings and may be used to upgrade or replace failed bushings on existing equipment in the field. For new switchgear designs, we suggest our higher performance “B” series bushings, which offer superior electrical performance, higher mechanical strength and numerous design advantages. 200 Amp Bushing Well - The #1101-225A2 bushing well is a small-shank design that can be used to replace older Elliott (and other manufacturer’s) clamp-in bushings using the existing mounting hole and clamp ring. The #1101-225A2 bushing well can also be used to replace the discontinued RTE® porcelain Safebreak Bushing when used with the Elliott #1991-CRAR clamp ring adapter. 600 Amp Bushing - The #1201-625A2 bushing is a large-shank design that uses the same mounting bolt Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 1509 Hamilton Road Phone 318-746-3296 pattern and clamp ring as the small-shank bushing, but requires a larger mounting hole. The #1201-625A2F is the same bushing, with a special flange that allows the use of a sealing gasket for in-oil application. It uses the same size mounting hole as the #1201-625A2, but requires a different mounting bolt pattern and clamp ring. Index Slots - Elliott “A2” bushings feature a keying hole or slots on the live end. Fuse clips and hinge kits are available that bolt directly to the bushing conductor and key in the slots to prevent rotation. Conductor Connection - Female threads in the live end of the conductor allow the attachment of live parts of almost any thickness. The bolted connection of current-carrying parts does not depend on current transfer through the fastener’s thread-to-thread contact. Additional advantages of the bolted connection are higher clamping pressure and elimination of exposed sharp threads that could initiate corona. RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 3 2015 200 Amp Bushing Well #1101-225A2 1.125” 8.625” 0.75” Dia. Copper Conductor Threaded 0.375”–16 x 1” Deep 0.150” 3.75” 2.5” 0.75” 200 Amp Bushing Well Interface 8.3 kV and 15.2 kV per IEEE Standard 386 Conductive Shielding Voltage Class.................................................. 25 kV Leakage Distance, Inches................................................ 17 Phase-to-Ground Voltage................................ 15.2 kV Dry Arcing Distance, Inches............................................. 8.5 BIL................................................................... 125 kV Mechanical - Strength Rating, Pounds AC Withstand - 1 Min. Dry............................... 40 kV Cantilever, Ultimate 2.5 inches past end.................. >250 10 Sec. Dew......................... 26 kV Tensile, Pounds........................................................ >2,500 DC Withstand - 15 Min. Dry............................. 78 kV Torsion, Inches-Pounds (bolt breaks)...................... >700 Corona Extinction Level - Minimum................ 19 kV Compression, Pounds.............................................. 20,000 Continuous Current......................................... 200 Amps Conductor (live end) Thread Size ................................... 0.375”–16 x 1” Momentary - RMS, Sym., 0.17 sec................. 10,000 Amps Net Weight, Pounds (kg) ................................................. 2.94 (1.34) RMS, Sym., 3 sec...................... 3,500 Amps The #1101-225A2 bushing well is a small-shank design that can be used to replace older Elliott (and other manufacturer’s) clamp-in bushing wells using the existing mounting hole and clamp ring. The #1101-225A2 bushing well can also be used to replace the discontinued RTE® porcelain Safebreak Bushing when used with the #1991-CRAR clamp ring adapter (page 7). Typical Specifications - 200 Amp 15-kV and 25-kV Bushing Wells Bushings shall be Elliott #1101-225A2, 25 kV Class (15.2 kV to ground) Air-Insulated Bushing Wells, 125 kV BIL, per IEEE Standard 386 Fig. 3 (200 A Bushing Well Interface 8.3 kV, 15.2 kV, and 21.1 kV) for use with either 8.3/14.4 kV or 15.2/26.3 kV separable insulated connectors (Elastimold®, Eaton's Cooper Power Systems or other approved equal). The bushing wells shall be pressure-molded cycloaliphatic epoxy with a 0.75-inch diameter copper conductor on the “air-insulated” side that is drilled and tapped 0.375-inch–16UNC x 1-inch deep to provide direct connection of the bus and/or live parts. Integral shielding shall be provided to eliminate partial discharge caused by off-center mounting and mounting holes that may have sharp edges or burrs. Bushing wells shall mount in a 2.75-inch diameter opening and bolt or clamp in place to allow field replacement with standard tools. To assure adequate strength for apparatus support, the bushing well shall withstand a minimum cantilever loading of 150 pounds for five minutes without damage. The bushing well interface shall be free of all voids, holes and heat sinks to assure proper mating with separable insulated connectors. Each bushing well shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches and with a bushing well plug (Eaton's Cooper Power Systems #IBWP225 or equal) installed in the well interface to accurately simulate operating conditions (gas or liquid dielectric in the interface shall not be acceptable for this test). Each bushing shall meet the requirements for 25 kV devices in accordance with IEEE Standard 386 (latest revision), including 100 percent production testing. Mounting Hole for #1101-225A2 Clamp Ring #1900-CR4S 4.25” Dia. Bolt Circle 4.5” 2.75” Dia. 1.5” 1.5” 1.5” 1.5” 1.5” 3.125” Dia. 4.5” 1.5” 0.3125”–18 x 1.25” Studs with Elliott #1900-CR4S Clamp Ring Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 0.1054” 0.375” Dia. Holes 1509 Hamilton Road Phone 318-746-3296 1.5” 1.5” 0.5” Radius All Corners RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp 600 Amp Bushing #1201-625A2 4.625” 10.125” 0.563” Page 4 2015 1.25” Dia. Tin-Plated Aluminum Conductor Tapped 0.625”–11 x 1” Deep (both ends of conductor) 0.150” 4.5” 3.25” 2.5” 1.25” 600 Amp Deadbreak Interface No. 1 8.3 kV and 15.2 kV per IEEE Standard 386 Conductive Shielding Voltage Class.................................................. 25 kV Leakage Distance, Inches................................................ 21 Phase-to-Ground Voltage................................ 15.2 kV Dry Arcing Distance, Inches............................................. 10 BIL................................................................... 125 kV Mechanical - Strength Rating, Pounds AC Withstand - 1 Min. Dry............................... 40 kV Cantilever, Ultimate 2.5 inches past end.................. >350 DC Withstand- 15 Min. Dry.............................. 78 kV Tensile, Pounds........................................................ >2,500 10 Sec. Dew......................... 26 kV Torsion, Inches-Pounds (bolt breaks)...................... >3,500 Corona Extinction Level - Minimum................ 19 kV Compression, Pounds.............................................. 20,000 Continuous Current......................................... 600 Amps Conductor (live end) Thread Size.................................... 0.625”–11 x 1” Momentary - RMS, Sym., 0.17 sec................. 25,000 Amps Net Weight, Pounds (kg).................................................. 6.01 (2.73) RMS, Sym., 3 sec...................... 10,000 Amps The #1201-625A2 bushing is a large-shank design that uses the same mounting bolt pattern and clamp ring as the small-shank bushing, but requires a larger mounting hole. The #1201-625A2F bushing (page 5) is the same basic design, except it features a special flange to allow the use of a sealing gasket for in-oil application. Typical Specifications - 600 Amp 15-kV and 25-kV Bushings Bushings shall be Elliott #1201-625A2, 25 kV Class (15.2 kV to ground) Air-Insulated Bushings, 125 kV BIL, per IEEE Standard 386 Fig. 11 (600 A Deadbreak Interface No. 1, 8.3 kV and 15.2 kV) for use with either 8.3/14.4 kV or 15.2/26.3 kV separable insulated connectors (Elastimold®, Eaton's Cooper Power Systems or other approved equal). The bushings shall be pressure-molded cycloaliphatic epoxy with a 1.25-inch diameter tin-plated aluminum conductor on the “air-insulated” side that is drilled and tapped 0.625-inch–11UNC x 1-inch deep to provide direct connection of the bus and/or live parts. Integral shielding shall be provided to eliminate partial discharge caused by off-center mounting and mounting holes that may have sharp edges or burrs. Bushings shall mount in a 3.5-inch diameter opening and bolt or clamp in place to allow field replacement with standard tools. To assure adequate strength for apparatus support, the bushing shall withstand a minimum cantilever loading of 200 pounds for five minutes without damage. The bushing interface shall be free of all voids, holes and heat sinks to assure proper mating with separable insulated connectors. Each bushing shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches and with an insulated protective cap (Eaton's Cooper Power Systems #DPC625 or equal) installed on the interface to accurately simulate operating conditions (gas or liquid dielectric on the interface shall not be acceptable for this test). Each bushing shall meet the requirements for 25 kV devices in accordance with IEEE Standard 386 (latest revision), including 100 percent production testing. Mounting Hole For #1201-625A2 Clamp Ring #1900-CR4S 4.25” Dia. Bolt Circle 3.5” Dia. 1.5” 1.5” 1.5” 1.5” 1.5” 3.125” Dia. 0.1054” 4.5” 1.5” 0.3125”–18 x 1.25” Studs with Elliott #1900-CR4S Clamp Ring Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 4.5” 0.375” Dia. Holes 1509 Hamilton Road Phone 318-746-3296 1.5” 1.5” 0.5” Radius All Corners RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp 600 Amp Bushing #1201-625A2F 4.625” 10.125” 0.563” Page 5 2015 1.25” Dia. Tin-Plated Aluminum Conductor Tapped 0.625”–11 x 1” Deep (both ends of conductor) 0.150” 4.5” 3.25” 2.5” 1.25” 600 Amp Deadbreak Interface No. 1 8.3 kV and 15.2 kV per IEEE Standard 386 Conductive Shielding Voltage Class.................................................. 25 kV Leakage Distance, Inches................................................ 21 Phase-to-Ground Voltage................................ 15.2 kV Dry Arcing Distance, Inches............................................. 10 BIL................................................................... 125 kV Mechanical - Strength Rating, Pounds AC Withstand - 1 Min. Dry............................... 40 kV Cantilever, Ultimate 2.5 inches past end.................. >350 10 Sec. Dew......................... 26 kV Tensile, Pounds........................................................ >2,500 DC Withstand - 15 Min. Dry............................. 78 kV Torsion, Inches-Pounds (bolt breaks)...................... >3,500 Corona Extinction Level - Minimum................ 19 kV Compression, Pounds.............................................. 20,000 Continuous Current......................................... 600 Amps Conductor (live end) Thread Size.................................... 0.625”–11 x 1” Momentary - RMS, Sym., 0.17 sec................. 25,000 Amps Net Weight, Pounds (kg).................................................. 6.2 (2.82) RMS, Sym., 3 sec...................... 10,000 Amps The #1201-625A2F bushing is a large-shank design that is similar to the #1201-625A2 (page 4), except it features a special flange to allow the use of a sealing gasket for in-oil application. The #1201-625A2F bushing uses the same mounting hole as the #1201-625A2, but requires a different mounting bolt pattern and clamp ring. Typical Specifications - 600 Amp 15-kV and 25-kV Bushings Bushings shall be Elliott #1201-625A2F, 25 kV Class (15.2 kV to ground) Air-Insulated Bushings, 125 kV BIL, per IEEE Standard 386 Fig. 11 (600 A Deadbreak Interface No. 1, 8.3 kV and 15.2 kV) for use with either 8.3/14.4 kV or 15.2/26.3 kV separable insulated connectors (Elastimold®, Eaton's Cooper Power Systems or other approved equal). The bushings shall be pressure-molded cycloaliphatic epoxy with a 1.25-inch diameter tin-plated aluminum conductor on the “air-insulated” side that is drilled and tapped 0.625-inch–11UNC x 1-inch deep to provide direct connection of the bus and/or live parts. Integral shielding shall be provided to eliminate partial discharge caused by off-center mounting and mounting holes that may have sharp edges or burrs. Bushings shall mount in a 3.5-inch diameter opening and bolt or clamp in place to allow field replacement with standard tools. To assure adequate strength for apparatus support, the bushing shall withstand a minimum cantilever loading of 200 pounds for five minutes without damage. The bushing interface shall be free of all voids, holes and heat sinks to assure proper mating with separable insulated connectors. Each bushing shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches and with an insulated protective cap (Eaton's Cooper Power Systems #DPC625 or equal) installed on the interface to accurately simulate operating conditions (gas or liquid dielectric on the interface shall not be acceptable for this test). Each bushing shall meet the requirements for 25 kV devices in accordance with IEEE Standard 386 (latest revision), including 100 percent production testing. Mounting Hole For #1201-625A2F Clamp Ring #1902-CR4-A2F 3.5” Dia. 5.125” Dia. Bolt Circle 1.8125” 1.8125” 1.8125” 1.8125” 1.8125” 3.25” Dia. 1.8125” 0.3125”–16 x 1.5” Studs with Elliott #1902-CR4-A2F Clamp Ring Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 4.5” 0.375” Dia. Holes 1509 Hamilton Road Phone 318-746-3296 1.8125” 1.8125” 0.25” 4.5” 0.5” Radius All Corners RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 25-kV Apparatus Bushings “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Bushing Well Plug or Cap Production Tests Every bushing is production tested in free air, mounted in an 11-gauge grounded steel plate not less than 10 inches x 10 inches, with an insulating protective plug (or cap) installed on the interface to accurately simulate operating conditions. Each bushing must meet or exceed the requirements for 15.2/26.3 kV devices in accordance with the test values of IEEE Standard 386 (latest revision) for partial discharge (corona) and AC voltage withstand when tested in this manner. Descriptive Bulletin 1125-200 Page 6 2015 Test Configuration High Voltage Electrode Grounded Steel Test Plate Installation Instructions Elliott “A” Series Apparatus Bushings clamp in place utilizing the mounting hole and hardware shown below. All mounting hardware is located on the elbow side of the equipment mounting plate to eliminate the possibility of reduced phase-to-ground clearance. Every Elliott Bushing is tested at the factory, mounted in a grounded steel plate. A greased bushing well plug (or insulating protective cap) is installed on the interface to accurately simulate operating conditions. To prevent contamination of the silicone grease, it is important to keep the shipping cap in place until you are ready to install the bushing insert (or elbow). Should the grease become contaminated, thoroughly clean the interface and reapply silicone grease before installing the bushing insert (or elbow). NOTE: The shipping cap on the bushing well (or bushing) should be left in place to prevent contamination of the interface. 4.25” Dia. Bolt Circle 4.25” Dia. Bolt Circle 2.75” Dia. 3.5” Dia. 1. The bushing installs from the elbow side. 2. A clamp ring is placed on the bushing. 3. Lock washers and lock nuts are installed on the studs (or bolts). The nuts should be tightened in a uniform manner (rather than one-by-one in a random sequence). Do not apply more than 90 inch-pounds torque to each nut. The studs should be left unpainted to provide a connection from the shielding to the grounded mounting plate. If the bushing is mounted on an ungrounded or insulated plate (such as fiberglass), a ground strap should be attached to one of the mounting studs. IMPORTANT: Do not energize this bushing with only the shipping cap in place. To do so would lead to failure of the bushing and create a hazard to operating personnel. This product is designed to be used only when it is mated with an appropriate 15 kV or 25 kV Class bushing insert (and/or elbow) conforming to the latest revision of IEEE Standard 386. The bushing insert (and/or elbow) should be installed in accordance with the instructions supplied by the connector manufacturer. 5.125” Dia. Bolt Circle 0.3125"–18 x 1.25" Weld Studs 1.5” 1.5” 1.8125” 1.5” 1.5” 1.8125” 1.5” 1.5” 1.5” 1.5” Mounting Hole For #1101-225A2 Mounting Hole For #1201-625A2 Mounting Hole For #1201-625A2F 0.3125”–18 x 1.25” Studs with Elliott #1900-CR4S Clamp Ring 0.3125”–16 x 1.5” Studs with Elliott #1902-CR4-A2F Clamp Ring 0.3125”–18 x 1.25” Studs with Elliott #1900-CR4S Clamp Ring 1.8125” 1.8125” Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 1509 Hamilton Road Phone 318-746-3296 Equipment Plate RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Descriptive Bulletin 25-kV Apparatus Bushings 1125-200 “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 7 2015 Replace existing RTE® 8.3-kV Safebreak Bushing with an Elliott Bushing Well and #1991-CRAR Clamp Ring Adapter #2700250A01 RTE® Clamp Ring #2600779C03 RTE® Safebreak Bushing 2.625" Dia. 0.375"–16 x 1" Stud 0.125" Equipment Plate 7” The #1991-CRAR Clamp Ring Adapter permits a #1101-225A2 Elliott Bushing Well to be mounted, with an RTE® Clamp Ring, in equipment originally equipped with the discontinued RTE® 8.3 kV porcelain Safebreak Bushing. The clamp ring is located on the elbow side of the equipment mounting plate to eliminate the possibility of reduced phase-to-ground clearance. The #1991-CRAR Clamp Ring Adapter comes complete with the bolts, nuts and washers shown below. 1.5” 8.5” #1991-CRAR Elliott Clamp Ring Adapter IMPORTANT: Do not energize this bushing with only the shipping cap in place. To do so would lead to failure of the bushing and create a hazard to operating personnel. This product is designed to be used only when it 0.75" Dia. is mated with an appropriate 15 kV or 25 kV Class Copper Conductor bushing insert conforming to the latest revision of IEEE Tapped 0.375"–16 x 1" Deep Standard 386. The bushing insert should be installed #1101-225A2 in accordance with the instructions supplied by the Elliott Bushing Well connector manufacturer. 2.625" Dia. 0.375"–16 x 1.75" S.S. Hex Bolt, Flat Washer, Lock Washer and Hex Nut #2700250A01 RTE® Clamp Ring (from existing equipment) Replacement Instructions NOTE: The shipping cap on the bushing well should be left in place to prevent contamination of the interface. 1. The existing RTE® bushing is removed, keeping the RTE® clamp ring for re-use. 2. The bushing well installs from the elbow side for easy installation. 3. The clamp ring adapter and RTE® clamp ring are placed on the bushing. 4. Flat washers, lock washers and nuts are installed on the bolts. The nuts should be tightened in a uniform manner rather than one-by-one in a random sequence. Do not apply more than 90 inch-pounds torque to each nut. 0.375" S.S. Lockwasher #2700250A01 RTE® Clamp Ring (from existing equipment) 0.375"–16 S.S. Hex Nut Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 0.4375" Dia. Holes (in equipment plate) 1509 Hamilton Road Phone 318-746-3296 #1991-CRAR Adapter 0.375"–16 x 1.75" S.S. Bolt #1101-225A2 Elliott Bushing Well 0.375" S.S. Flat Washer Equipment Plate RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 25-kV Apparatus Bushings “A” Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Descriptive Bulletin 1125-200 Page 8 2015 If you do not find the design you need PLEASE CONTACT our REPRESENTATIVE or the FACTORY Elastimold® is a registered trademark of ABB Asea Brown Boveri Ltd. Elliott Molding and Components A Division of Elliott Industries, Inc. © Copyright 2015 1509 Hamilton Road Phone 318-746-3296 RTE® is a registered trademark of Eaton in the U.S. and other countries. Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com