Functional Test PC: ITEM: ID: AREA SERVED: 237313 Air Handling Unit AHU-1 Office and Support Areas The above equipment and systems integral to them are complete and ready for functional testing per Mechanical and Controls Contractors. The prefunctional checklist items are complete and have been checked off only by parties having direct knowledge of the event. This construction checklist is submitted for approval, subject to an attached list of outstanding items yet to be completed (See Notes and Associated Project Issues Log). None of the outstanding items preclude safe and reliable functional tests being performed. This Checklist does not take the place of the manufacturer’s recommended checkout and startup procedures or report. Construction checklist items are to be completed as part of startup and initial checkout. Approvals. This filled-out checklist has been reviewed. Its completion is approved with the exceptions noted below. Byce & Associates 09/10/13 Commissioning Authority Date Owner’s Representative Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 1 Date AHU-1 Information Make Trane, Size 25 Serial Number Volts/Phase Model Number K13D29181 460/3 Location Capacity 1210 Mechanical CSAA025UAD00 190 MBH Htg., 403 MBH Clg. Service Area CFM 11,500 CFM Office and Support Areas Comments: Design 190 MBH Htg. (14 GPM) 403 MBH Cooling (87 GPM) 6,300 CFM Min. Supply Air 720 CFM Min. Outside Air Components Included Supply Fan Economizer Cooling Coil Return Fan Air Blender Heating Coil Exhaust / Relief Fan Filter(s) Energy Recovery Wheel VFD(s) Humidifier Other Comments: Total Enthalpy energy recovery wheel. Requested documentation submitted Rec’d Manufacturer’s cut sheets Performance data (fan curves, coil data, etc.) Installation and startup manual and plan O&M manuals Factory test results Sequences and control strategies Warranty Certificate Comments: Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 2 Comments Operational Checks Check if acceptable, provide comment if unacceptable NA Comments Supply fan rotation correct Return fan rotation correct Return fan has no unusual noise or vibration Supply fan has no unusual noise or vibration All dampers stroke fully without binding and spans calibrated. List each actuated damper here when spanned: Exhaust Air Damper: X Small leakage (light) in installed “Ruskin” mixed air AHU damper to be replaced w/ “Tamco” at future date T.B.D. Outside Air Damper: X All dampers stroked 100% of span with no binding. Mixed Air Damper: X ERW Bypass Dampers: X Valves stroke fully and easily and spanning is calibrated. List each actuated valve here when spanned: Heating Water: X Htg. valve stroked 100% of span. Clg. valve stroked 100% of span. Chilled Water: X Valves verified to not be leaking through coils when closed at normal operating pressure. The HOA switch properly activates and deactivates the unit. Supply Air duct static pressure sensor is located 2/3rds down longest supply duct in duct and not subject to turbulence from elbows, vanes, etc. Record location of sensor: Record sensor reading at BMS: Verify sensor setpoint from TAB Report: 1.08” S.P. (varies) Duct SP sensor located in Rm. 1020. .94” w.c. S.P. (Varies in relation to AHU-2 space pressure.) from programmed offset. Outdoor air sensor is reporting reliable values. Record location of OA sensor: Record sensor temperature reading at BMS: WMU central server location. (Global) 84.2 deg. F. Supply fan current sensor mapped correctly to BMS. Verify alarm at BMS upon flow failure. Alarm to BMS was generated. Supply fan VFD speed reporting reliable values. Record reading at BMS. Record VFD Hz at minimum and maximum: Verify trouble input at VFD generates alarm at BMS. 71% of range, 48.1 Hz. 0-100% speed range. 0-68 Hz. Frequency range. Alarm generated to BMS. Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 3 Operational Checks Check if acceptable, provide comment if unacceptable Supply airflow monitoring station reporting reliable values. Record reading at BMS. Record supply airflow with all terminal units at maximum airflow position: Record supply airflow with all terminal units at minimum airflow position: NA Comments 12,144 CFM, 63 deg. F. 12,100 CFM Max. TU box flow. 6,300 CFM Min. TU box flow. Supply air temperature sensor reporting reliable values. Record Discharge Air Temperature reading at BMS: 60.6 deg. F D.A.T. 65 deg. (adj.) D.A.T. S.P. Cooling coil valve position reporting reliable value. Record valve position reading at BMS: Cooling valve at 0% open. Heating coil valve position reporting reliable value. Record valve position reading at BMS: Heating valve at 0% open. Return air damper position mapped correctly at BMS. Verify failure to open generates alarm at BMS. Alarm generated to BMS. Outdoor air damper position mapped correctly at BMS. Record minimum outdoor airflow: Verify minimum damper position and associated airflow from TAB Report: 1,800 CFM Min. O.A. Verify failure to open generates alarm at BMS. Alarm to BMS generated. Verify demand control ventilation programming based on outdoor air and return air CO2 level. Record return air CO2 level setpoint: Record return air CO2 level at BMS: Record outdoor air CO2 level at BMS: 1,000 ppm RA setpoint. 556 ppm Avg. RA Baseline OA CO2 level needs to be added to BMS & graphics. Exhaust air damper position mapped correctly at BMS. Verify failure to open generates alarm at BMS. Alarm generated to BMS. Mixed air temperature sensor reporting reliable values. Record high and low temperature alarm setpoints: 45 deg. F. M.A.T. setpoint (low temp) Record Mixed Air Temperature reading at BMS: Verify alarm at BMS if reading reaches setpoints: 77.4 deg. F. M.A.T. Alarm generated to BMS. Exhaust fan current sensor mapped correctly to BMS. Verify alarm at BMS upon flow failure. Alarm generated to BMS. Exhaust fan VFD speed reporting reliable values. Record reading at BMS: Verify trouble input generates alarm at BMS. Record VFD Hz at minimum and maximum: 97.6% of speed range, 65.3 Hz. 0-100% speed range. 0-68 Hz. range. Alarm generated to BMS. Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 4 Operational Checks Check if acceptable, provide comment if unacceptable Return airflow monitoring station reporting reliable values. Record reading at BMS. Record return airflow with building pressure above setpoint: NA Comments SA offset deadband of 50 CFM and tracks AHU S.A. 9,499 CFM R.A. above S.P. Record return airflow with building pressure below setpoint: 11,192 CFM R.A. below S.P. Return air temperature sensor reporting reliable values. 76.1 deg. F. R.A.T. Record reading at BMS: Building Pressure reporting reliable values. Record pressure sensors location: Record Building Pressure reading at BMS: Space pressure based off pressure relationship and 1% offset to AHU-2 zone. AHU flow graphic is correct in BMS Graphic easily displays system On/Off, O.A. CO2 & set point missing from BMS. Refer to note 4. Specified sequences of operation and operating schedules have been implemented with all variations documented Specified point-to-point checks have been completed and documentation record submitted for this system. All alarm points have been tested and confirmed. Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 5 Functional Testing Mode ID Test Procedure Response (including special conditions) AHU Scheduling Unoccupied Verify scheduling of unit on BMS. In Occupied Mode: Verify supply and return fans are on, outside air damper is open. Put fan(s) in off manually; verify alarm at BMS upon fan failure. Record heating and cooling set points in unoccupied mode: Unocc HTG: Unocc CLG: Schedule unit in unoccupied mode. Verify supply and return fans are off, the heating and cooling coil valves are closed, the outdoor air damper is closed, the return air damper is open, and the exhaust air damper is closed. Note # Y/N Y Fan alarm generated to the BMS. Record mixed air temperature setpoint in unoccupied mode: Adjust mixed air temperature set point in unoccupied mode. Verify heating valve opens when mixed air temperature is below unoccupied mixed air temperature setpoint. Record testing setpoint adjustment: VFD Operation Pass Maintain unit is unoccupied mode. Ensure mixed air temperature is above unoccupied mixed air temperature set point. Adjust a terminal unit downstream of AHU unoccupied setpoint to be above space temperature. Verify AHU supply fan cycles on, heating valve opens to maintain terminal unit space temperature at or above night setback temperature. Record TU and testing setpoint adjustment: Adjust supply duct static pressure setpoint. Allow unit to stabilize. Verify supply fan speed modulates to maintain static pressure setpoint. Verify supply airflow monitoring station modulates accordingly. Record BMS static pressure setpoint: Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 6 Y Y Y Y Functional Testing Mode ID Test Procedure Response (including special conditions) Record static pressure setpoint adjustments made for testing: Record airflow variation: Outside Air Return Air Discharge Air Temperature / Economizer Note # Y/N BMS space pressure and setpoints are not in the BMS graphics. Adjust building pressure setpoint. Allow unit to stabilize. Verify return fan speed modulates to maintain building static pressure setpoint. Verify return airflow monitoring station modulates accordingly. Record building pressure setpoint: Record building pressure setpoint adjustments made for testing: Record airflow variation: Verify outdoor air damper modulates to maintain TAB minimum outdoor airflow. Record cfm from BMS: Override outdoor air damper to 0%, start unit from unoccupied. Verify supply fan does NOT start unit outdoor air damper is verified open. Override return air damper to 0%, start unit from unoccupied. Verify supply fan does NOT start unit return air damper is verified open Adjust discharge air temperature as required. Allow unit to stabilize between variations. Verify outdoor damper, relief air damper, heating coil valve, and cooling coil valve operate in sequence to maintain discharge air setpoint. Record discharge air temperature setpoints (55°-65°F) and reset schedule: Y Y Y Y Y Verify when outdoor air temperature is below 55 degrees, dampers modulate to maintain supply air temperature of 55 degrees. Verify when outdoor air temperature is above 55 degrees and return air enthalpy is greater than the outdoor air enthalpy, the return air damper and outdoor air damper modulate for free cooling while maintaining discharge air temperature. Record discharge air temperature here: Pass Y Y Y 65.4 Deg. F. DAT Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 7 Functional Testing Mode ID Test Procedure Response (including special conditions) Demand Control Ventilation Damper Positions Morning WarmUp Safety – Freeze Protection Safety – High Temperature Protection Safety – Smoke Detection Verify when supply fan is off, outdoor and exhaust dampers are closed. Return damper is open. Verify Morning Warm-Up is scheduled through BMS. Record warm up schedule. Allow unit to be in Morning Warm-Up, verify supply fan is ON, return fan is ON, heating valve is OPEN, cooling valve is CLOSED, outdoor air damper is CLOSED, return air damper OPEN, relief air damper CLOSED until return air temperature reaches 70°F. Once return air temperature rises above 70°F, verify the unit cycles back to occupied mode and all valves and dampers respond to occupied mode. Create freeze stat alarm at freeze stat. Verify BMS alarm is generated. Verify fans are OFF, outdoor air damper is CLOSED when temperature upstream of supply fan is below 37 degrees. Record freeze stat temperature alarm if different than 37 degrees. Verify fans are OFF, outdoor air damper is CLOSED when return air temperature is above 120 degrees. Verify BMS alarm is generated. Create smoke detection alarm at smoke detector wiring. Verify BMS alarm is generated. Verify fans are OFF, outdoor air damper is CLOSED when smoke is detected. Note # Y/N Verify when outdoor air temperature is above 55 degrees and return air enthalpy is lower than the outdoor air enthalpy, the return air damper and outdoor air damper are at minimum position, relief damper is closed, and return damper is open. Verify when outdoor air temperature is above 65 degrees, the outdoor air damper is at minimum, relief damper is closed, and return damper is open. Verify outdoor air damper modulates open upon a maximum return air CO2 level of 600 ppm. Record minimum outdoor air position with return air CO2 level less than 600 ppm: Pass Y Y Y RA C02 not in BMS graphics Y Y N/A Pursuant to T.C.C. Seq. of Op’s 15 min time delay scheduled Y 35 deg. F. low limit S.P. Y Two (2) L.L. devices due to coil size. Y N/A Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 8 Y Note 1 Comments: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Safety/Smoke detection alarm shut down not commissioned, devices verified by Fire Marshall testing. SA and RA “Photohelic” pressure gauges need to be labeled. Interior unit segment casings are dirty and need vacuum cleaning. OA CO2 detector device and value are missing from the AHU-1 graphic at BMS. View Window inside frame for RA fan section is loose. Ruskin dampers (ALL) to be replaced with Tamco. .136” w.c. ER wheel delta P 42% E.A. Rel. humidity. 40% O.A. Rel. humidity. 58% R.A. Rel. humidity. 57% S.A. Rel. humidity. Loose heating coil circulator support corrected at time of Functional Testing by MCM. Legacy Collections Center Western Michigan University B/A #12100284 / WMU Project No. R8952 FUNCTIONAL TEST – AIR HANDLING UNIT PC 237313 - 9