Professional Provider of Power Testing Instrument TP YCT M type CT PCT200 Series CT/PT Test System PT Bushing type CT M type CT Bushing Type CT GIS CT PT PONOVO POWER CO., LTD. 2F,4Cell, Tower C, In.Do Mansion, No.48A Zhichun Road, Haidian District Beijing, PR China (100098) Tel. +86 (10) 8275 5151(reception) Tel. +86 (10) 8275 5151ext.8887 Fax. +86 (10) 8275 5151-8103 support@relaytest.com info@relaytest.com www.relaytest.com PONOVO POWER CO., LTD Principle Excitation characteristics test based on DC method Ratio test based on voltage method < Conventional method> <Conventional method> T2 A TAx v Features : A Current source T1 s A Current source is at primary side and current measurement is at the secondary side 1 . Test CT according to IEC60044-1/6 and ANSI/IEEE C57.13 2. Can test all types of CT 3. One test can get all CT parameters 4. Fast test for excitation check <New method > <New method> VariableFrequency power source 1kV knee point check time: 15s TAx V Voltage source A 10kV knee point check time: 50s V v Voltage source is at secondary side and Voltage measurement is at primary side Features of new method: Features of new method: Ratio check up to 30000:1 q Can check CT with high knee point value q Can check bushing CT q q High efficiency, high accuracy, more safe Can check GIS CT q Error check with extrapolation method for M type CT Test special CT P1 S1 P2 S2 Load Current source P1 CT under test P2 K2 S1 K1 A S2 V V Load Voltage source L2 Standard CT L1 CT Tester q Bushing type CT requires large power output capacity 01 Get the ratio error and angle error based on q which conventional CT tester can not give. New test method can solve this problem extrapolation method, no need to use extra standard CT nor standard load. The primary side length is long for GIS type CT and this q requires large power output capacity which conventional CT test can not supply. New test method can solve this problem 02 www.relaytest.com Test at field Test Report Simple wiring PCT200i Report PCT series report analyze software P1 S1 Load S2 P2 Standard Accessories Soft bag Test leads Software Interface Signal Cable( Double wired) 2.5mm2 ×3m×2 PCT200i operation Easy ate r e p o to ! Transportation Case (Anti Water & vibration) Signal Cable(Double wired) 0.75mm2 ×15m×1 Earthing Lead with Clap 4mm2 ×3m×1 q Excel format test report A4 size q q Test result can be exported to key drive through USB port. q Can save 10.000 results in non-volatile memory www.relaytest.com 03 Claps with Jaws open 30mm×4 Spike Test Pen×2 Cable Connector×2 Claps with Jaws open 10mm×4 04 www.relaytest.com Comparison with traditional method Shan Xi CT/PT Research Institute Field Test Examples Customer: Beijing High Transmission Company Comparison of excitation tests between conventional test method and PCT200i Comparison with traditional test method 500kV TPY(transient) type CT Test data Report Test results Chongqing Power Plant Generator Output CT C omparison test with traditional CT test method was made in Shan Xi CT & PT Research Institute. 0.2 class reference CT was used in the test. The results show the maximum Ratio test difference is 0.08414% and the maximum Phase deviation test difference is 0.34188’. Generator output 6000:1 Test Result www.relaytest.com 05 06 www.relaytest.com Szechwan Substation (500kV) Tianjing Huapanshan Power Plant Shen yang CT/PT factory Shan Xi 500kV Substation 500kV Tranformer Bushing CT 220kV Transmission Line CT 500kV Class CT TPY 4000:1 Test result 500kV Transformer Casing CT TPY Class TPY Class 1250:1test Datasheet Shen yang CT/PT factory 220kV Transmission line GIS CT P Class 1250:1 excitation characteristic curve Generator Output TPY CT 200 kV transmission line GIS CT Class P 1500:1 Test result www.relaytest.com 07 08 www.relaytest.com PCT200 Series CT/PT Test System Specifications Application Specifications Test M/P/TP type CT and PT Test M/P/TP type CT and PT 0 ~ 120V 0 ~ 120V Output current range 0~5Arms(15A peak) 0~5Arms(15A peak) 0.0001~500VArms(1500VA peak) 0.0001~500VArms(1500VA peak) 35000:1 ~ 45000:5 35000:1 ~ 45000:5 Ratio test range Ratio test accuracy Max. knee point voltage Burden test range Burden test accuracy Winding resistance test rang Winding resistance test accuracy Accuracy limiting factor (ALF) ±0.1% ±0.05% 45000V 45000V 0.05~200Ω ±0.05%±1mΩ Typ. ±0.1%±1mΩ Gur. 0.05~200Ω ±0.05%±1mΩ Typ. ±0.1%±1mΩ Gur. 0.05~200Ω ±0.05%±1mΩ Typ. ±0.1%±1mΩ Gur. 0.05~200Ω ±0.05%±1mΩ Typ. ±0.1%±1mΩ Gur. Yes Yes Instrument security factor (FS) Yes Yes Remanence flux (Kr) Yes Yes Secondary time constant (Ts) Yes Yes Unsaturated inductance (Lu) Yes Yes Saturated inductance (Ls) Yes Yes Excitation characteristic curve Yes Yes 10%(5%)error curve Yes Yes Rated symmetrical short circuit current factor (Kssc) Accuracy limiting voltage (Eal) Yes Yes Yes Yes Transient dimensioning factor (Ktd) Yes Yes Peak instantaneous error (ε^ ) Yes Yes Composite error (εc ) Yes Yes Ratio error Phase displacement Others PCT200Ai Output voltage range Output power CT PCT200i Main supply Operation temperature Relative humidity Dimensions Weight LCT display Operating system www.relaytest.com ±0.05%Typ. ±0.1%Gur. ±0.02% Typ. ±0.05% Gur. 1min Typ. 3min Gur. 1min Typ. 2min Gur. 0.1min 0.01min 110-240Vac/50-60Hz (norminal) 90-260Vac/45-65Hz (permissible) 110-240Vac/50-60Hz (norminal) 90-260Vac/45-65Hz (permissible) -10°С~50°С -10°С~50°С ≤90%,non-condensing ≤90%,non-condensing 470 x200 x 245mm (W×H×L) 470 x200 x 245mm (W×H×L) 11Kg 11Kg 1Kg 8.4 inch, color display 8.4 inch, color display windows windows 09 10 www.relaytest.com