Pressure gauges Model 232.XX.063 per directive 94/9/EC (ATEX) with alarm contacts Model 831 II 2 GD c Contents 1. 2. 3. 4. 5. 6. 7. 8. Safety instructions Description Technical data and intended use Alarm contacts Commissioning Maintenance and servicing / cleaning Repairs Disposal Enclosure 1: Declaration of conformity for Models 232.XX.63 with alarm contacts Model 831 11133104.02 05/2014 D/GB Operating Instructions GB Enclosure 2: EC-type examination certificate (Ex approval for gases and dust) for slottype proximity sensors Si2-K08-Y1X (WIKA-Model 831) WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de 1. Safety instructions ! Caution The appropriate national safety regulations (e.g. VDE 0100 / EN 60 079-14 / EN 837-2) must be observed when installing, putting into operation and running these instruments. T Do not work on gauge while under voltage T Serious injuries and/or damage can occur should the appropriate regulations not be observed T Only appropriately qualified persons should work on these instruments 2. Description T Nominal size 63 mm T The pressure gauges measure the pressure by means of resilient bourdon tube measuring elements T The measuring features are in accordance with the standards EN 837-1 T In addition the case and bezel ring as well as the pressurised components of models 232.3X also meet the requirements of this standard on safety pattern pressure gauges with solid baffle wall (code S3). The built-in electrical alarm contacts are non-contact slot-type inductive proximity sensors, which are supplied from control units with circuits that are certified to be intrinsically safe. When the adjustable set points are reached, their output circuits will be opened or closed. The connection values of the switches are in accordance with EN 60 947-5-6 ("NAMUR"). 3. Technical data and intended use Working pressure Steady: Fluctuating: Short time: full scale value 0.9 × full scale value 1.1 × full scale value Pressure connection T According to the general technical regulations for pressure gauges, respectively (e.g. EN 837-2 "Selection and installation recommendations for pressure gauges"). When screw-fitting the gauges the force required for sealing must not be applied through the case but, using a suitable tool, only through the spanner flats provided for this purpose at the square of the connector. Installation with open-ended spanner Temperature effect When temperature of the pressure element deviates from reference temperature (+20 °C): max. ±0.4 %/10 K of true scale value IP Ingress protection Enveloping case IP 54 resp. IP 65 as special feature (EN 60 529 / IEC 60 529) Materials Wetted parts: Movement: Dial and pointer: Case, bezel ring: Window: Stainless steel Stainless steel Aluminium Stainless steel Polycarbonate Installation T Nominal position per EN 837-1 / 9.6.7 Figure 9: 90° ( ) T Pressure connection: lower mount (LM) or back mount (BM) T In order to ensure that with models 232.3X pressure can be safely and reliably vented through the case back, a distance of at least 25 mm has to remain free behind the case! T In order to avoid any additional heating, the instruments must not be exposed to direct solar irradiation while in operation! Permissible vibratory stress at the mounting location T As a matter of principle the instruments should only be mounted at locations without vibratory stresses T Where required, a decoupling from the mounting location can be achieved e.g. by a flexible connecting line from the measuring point to the pressure gauge and mounting via a measuring instrument bracket. T If this is not possible, the following limits must not be exceeded: Frequency range < 150 Hz Acceleration < 0.5 g (5 m/s2) Operating Temperature Ambient: -25 ... +60 °C Attention: Footnote 1) under table 1 must be absolutely taken into account! Medium: see table 1 Attention! With gaseous substances the temperature may increase as a result of the compression temperature. In such cases the pressure change rate has to be slowed down resp. the permissible medium temperature has to be reduced. Table 1: Permissible medium temperature (only mechanical part) Ignition temperature of the ambient atmosphere (temperature class) Permissible maximum medium temperature (in the pressure system) T6 T5 T4 T3 T2 T3 +70 °C +85 °C +120 °C +185 °C +200 °C +200 °C ( > 85 °C) ( > 100 °C) ( > 135 °C) ( > 200 °C) ( > 300 °C) ( > 450 °C) 1) The permissible upper ambient temperature for the electrical components is determined by the electrical connection values and the ignition temperature of the ambient gases, vapours and dusts. Therefore the maximum permissible ambient temperatures specified in the EC-type examination certificates for slot-type sensors and SN sensors must be observed as well. The lower of these two values is to be considered the maximum permissible ambient temperature! 4. Alarm contacts EC-type examination certificates The proximity sensors are in accordance with EC-type examination certificate KEMA 01 ATEX 1264 X. The built-in sensor type is stated on the product label of the pressure gauge. Contact function index The contact function of the switch is identified by the indices 1 or 2. 831.1 = NO - normally open, contact makes (clockwise pointer motion) 831.2 = NC - normally closed, contact breaks (clockwise pointer motion) Wiring details T The electrical connections should be made by qualified electricians T Cable outlet 2 m length, conductor cross section 0.14 mm2, flying leads T The terminal assignment is stated on the connection plate at the pressure gauge ! Caution T The instruments are to be included in the equipotential bonding of the plant! The permissible limits of the intrinsically safe supply circuits: Ui = 15 V Ii = 60 mA Pi = 100 mW for temperature class T6 resp. 150 mW for temperature class T4 Suitable switch amplifiers are e.g.: Model designation of the manufacturer Fa. Pepperl & Fuchs EC-type examination certificate WIKAModel KFD2-SR2-Ex1 KFD2-SR2 Ex2 KHA6-SR2-Ex1 KHA6-SR2-Ex2 PTB 00 ATEX 2080 PTB 00 ATEX 2080 PTB 99 ATEX 2141 PTB 99 ATEX 2141 904.31 904.32 904.28 904.29 Electromagnetic compatibility EMC according to EN 60 947-5-2. The instruments are to be protected against strong electromagnetic fields. To adjust red set pointers The red set pointers for the alarm contacts are adjustable over the adjustment lock in the window with the aid of the adjustment key (included in delivery). Red set pointers Adjustment lock The red set pointers for the alarm contacts are adjustable over the full range of the instrument. Switching points shall be set in the ranges between 10 % und 90 % of the scale to ensure switching accuracy and long life of the mechanical measuring system. 5. Commissioning During the commissioning process pressure peaks must be absolutely avoided. Open the shut-off valves slowly. 6. Maintenance and servicing / cleaning The instruments require no maintenance or servicing. The indicator and switching function should be checked once or twice every 12 months. The instrument must be disconnected from the process to check with a pressure testing device. The instruments should be cleaned with a damp cloth moistened with soap solution. Remainder of the pressure medium in dismounted pressure gauges may be hazardous or toxic. This should be considered when handling and storing the removed pressure gauges. 7. Repairs Repairs are to be only carried out by the manufacturer or appropriately trained personnel. For further details see WIKA data sheet PM 02.02, PM 02.04 or PM 02.11. 8. Disposal Dispose of instrument components and packaging materials in accordance with the respective waste treatment and disposal regulations of the region or country to which the instrument is supplied. Enclosure 2 The gauges are marked with Die Geräte werden gekennzeichnet mit Armin Hawlik Leiter Logistikzentrum 2 Manager Production and Logistics Klingenberg, 08.07.2005 Werner Hünerth Leiter Qualitätssicherung Quality Assurance Manager WIKA Alexander Wiegand GmbH & Co. KG Geschäftsbereich Prozessinstrumentierung / Division Process Instrumentation II 1 G EEx ia IIC T4 ... T6 II 1 D T95°C The built-in alarm contacts 831 are EC-type-certified. Numbers of certificates and marking Die eingebauten Grenzsignalgeber 831 sind EGbaumustergeprüft. Die Nummern der Prüfbescheinigungen und die Kennzeichnung KEMA 01 ATEX 1264 X Applied standards: EN 13463-1 General requirements EN 13463-5 Constructional safety 'c' Angewandte Normen: EN 13463-1 Allgemeine Bestimmungen EN 13463-5 Konstruktive Sicherheit 'c' II 2 GD c The dossier is retained under file nr. 8000550026 at the notified body No. 0032 TÜV NORD CERT Am TÜV 1 D-30519 Hannover Datenblätter / data sheets PM 02.04 PM 02.11 PM 02.02 Die Unterlagen werden aufbewahrt unter der Aktennummer 8000550026 bei der benannten Stelle Nr. 0032 TÜV NORD CERT Am TÜV 1 D-30519 Hannover WIKA-Typen / WIKA models 232.30.063 232.35.063 232.50.063 Directive 94 / 9 / EC (ATEX) Declaration of Conformity We declare under our sole responsibility that the products mentioned below, i.e. bourdon tube pressure gauges, according to the current data sheets correspond with the directive and were subjected to the conformity assessment procedure 'Internal Control of Production'. Konformitätserklärung Richtlinie 94 / 9 / EG (ATEX) Wir erklären in alleiniger Verantwortung, dass nachstehend genannte Produkte, Druckmessgeräte mit Rohrfeder, gemäß gültigen Datenblättern mit der Richtlinie übereinstimmen und dem Konformitätsbewertungsverfahren 'Interne Fertigungskontrolle' unterzogen wurden. Enclosure 1