Document

advertisement
Rocker Switch
For Additional Options Refer to Page E4-E6
TRD Series
MATERIAL SPECIFICATIONS:
TYPICAL PERFORMANCE CHARACTERISTICS:
Contacts ................................. Gold over nickel or silver plate
Case Material ........................ Polyamide, black matte finish
Actuator Material .................. Polyamide
Terminals/Fixed Contacts ..... Copper alloy with gold or silver plate
Terminal Seal ........................ Epoxy
Contact Rating ...................... 0.4 VA Max. @ 20 VDC or peak AC
3 A @ 125 VAC or 28 VDC (2 pos.) 2A
Initial Contact Resistance ..... 20 Milliohms max.
Contact Timing ..................... Break-before-make
Insulation Resistance ............ 1,000 Megohms min.
Dielectric Strength ................ 500 Volts RMS @ sea level
Actuator Travel ..................... 23°
Life Expectancy .................... 2 Pos. - 100,000 actuations
3 Pos. - 50,000 actuations
UL recognized under the Component Program of Underwriters
Laboratories Inc. File #E46765
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature ......... -4°F to +176°F (-20°C to +80°C)
Storage Temperature ............. -49°F to +199°F (-45°C to +93°C)
NOTE: When hand soldering, solder with switch in closed position.
Solder temperature 550-600°F less than 5 seconds.
NOTE: Part numbering sequence page E4
.550
(13.97)
.345
(8.76)
DPDT
.750
(19.1)
.508
(12.9)
23°
.150
(3.81)
Model
Type
Function
.020
(0.51)
.100
(2.54)
Act. Code
Pg. M8
Contact
.508
(12.9)
.150
(3.81)
Terminal
Model
Type
TRD13D1(*)WL
TRD13E1(*)WL
TRD13F1(*)WL
TRD23N1(*)WL
TRD23P1(*)WL
TRD23R1(*)WL
23°
SPDT
On None On
SPDT
On Off On
SPDT
On None (On)
DPDT
On None On
DP3T
On Off On
DPDT
On None (On)
(On) indicates momentary position.
23°
.265
(6.73)
.070
(1.77)
.820
(20.8)
.265
(6.73)
.150
(3.81)
.375
(9.52)
.740
(18.8)
.715 .840
(21.3) (21.3)
.755
(19.2)
ANODE
Model
Type
.100
(2.54)
TYP.
Function
CATHODE
Act. Code
Pg. M8
Contact
Terminal
Silver
Silver
Silver
Silver
Silver
Silver
Wire Lug
Wire Lug
Wire Lug
Wire Lug
Wire Lug
Wire Lug
SPDT
.130
(3.30)
.080
(2.03)
GREEN
CATHODE
COMMON
.100
(2.54)
TYP.
.025
(0.64)
TYP.
Terminal
Model
.080
(2.03)
.040
(1.01)
.078
(1.98)
.065
(1.65)
15/32-32
UNS-2A
TRD11D10WLLR
Standard Body and Rocker Color - (Black)
Type
Function
Act. Code
Pg. M8
TRD11D10WLLR(*) SPDT
On None On
1
Gold
Wire Lug
TRD13D10WLLR(*)
SPDT
On None On
TRD11E10WLLR(*)
SP3T
On Off On
5
Gold
Wire Lug
TRD13E10WLLR(*)
SP3T
On Off On
TRD11F10WLLR(*)
SPDT
On None (On)
1
Gold
Wire Lug
TRD13F10WLLR(*)
SPDT
On None (On)
(*) Specify LED color by adding suffix number: (2) Red, (4) Yellow, (5) Green, (25) Red/Green - Bi-color
(On) indicates momentary position.
Need more technical information?
Consult your local Augat sales office
listed on the back cover
1
5
1
2
6
2
Contact
.006
(0.15)
RED
.200
(5.08)
Act. Code
Pg. M8
.345
(8.76)
.377
(9.57)
.550
(13.8)
Function
.508
(12.9)
.150
(3.81)
TRD21N10WL
Standard Body Color - (Black)
.510
(12.9)
15/32-32
UNS-2A
THD.
.080
(2.03)
TRD11D1(*)WL
SPDT
On None On
1
Gold
Wire Lug
TRD11E1(*)WL
SPDT
On Off On
5
Gold
Wire Lug
TRD11F1(*)WL
SPDT
On None (On)
1
Gold
Wire Lug
TRD21N1(*)WL
DPDT
On None On
2
Gold
Wire Lug
TRD21P1(*)WL
DP3T
On Off On
6
Gold
Wire Lug
TRD21R1(*)WL
DPDT
On None (On)
2
Gold
Wire Lug
(*) Specify rocker color by adding suffix number: (0) Black (2) Red, (6) Blue (9) Yellow,
.750
(19.1)
.265
(6.73)
.130
(3.30)
.130
(3.30)
.040
.080
(1.02) w x (2.03)
OBLONG HOLE
TYP.
.078
(1.98)
E
.006
(0.15)
E3
1
5
1
Contact
Gold
Gold
Gold
Terminal
Wire Lug
Wire Lug
Wire Lug
AUGAT Inc.
452 John L. Dietsch Blvd.
Attleboro Falls, MA 02763 USA
(508) 699-9800 FAX (800) 533-2526
TRD Series
Rocker/Paddle • How To Order
MATERIAL SPECIFICATIONS:
TYPICAL PERFORMANCE CHARACTERISTICS:
Movable Contacts ................. Copper alloy w/silver inlay contact or
gold plate
Terminals/Fixed Contacts ..... Copper alloy w/silver inlay contact or
gold plate
Terminal Seal ........................ Epoxy
Housing/Beveled Frame ....... Polyamide, black matte finish
Contact Rating ...................... Silver: 3A max. @ 125 VAC, option 3
Gold: 0.4VA max. @ 20 VDC, option 1
Initial Contact Resistance ..... 20 Milliohms max.
Static Withstanding ............... 15KV, per IEC 801-2
Insulation Resistance ............ 1,000 Megohms min. @ 500 VDC
Dielectric Strength ................ 500 Volts RMS @ sea level
Electrical Life
2 Pos. 20K cycles @ full rated 3A load, 80K
@ 0.4VA, 3 pos. 10K cycles @ full rated 3A
load, 60K @ 0.4VA
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature ......... -4°F to +176°F (-20°C to +80°C)
Storage Temperature ............. -49°F to +199°F (-45°C to +93°C)
Solder Heat Resistance ......... Meets MIL-STD-202, method 210
*NOTICE: Caution should be used when hand-soldering. Solder heat Resistance -550°-600°F for less than 5 seconds. Solder with the switch in the
closed position.
UL recognized under the Component Program of Underwriters Laboratories Inc. File #E46765
See pages M2-M4 for application specific indexing.
HOW TO ORDER
E
Model
Contact
Rating
Function
TRD1
Single Pole
D on-on
Single
Pole
TRD2
Double
Pole
E
F
G
H
on-off-on
on-(on)
(on)-off-(on)
on-off-(on)
Actuator
3
Silver
3A
Double Pole
Terminal
1
Rocker
WL Wire Lug
2
Paddle
WW Wire Wrap
0 black
2 red
6 blue
1
Gold
0.4VA
Actuator
Color
Mount
L.E.D.
Illumin.
2 red
4 yellow
LR
Integral w/rocker
(TRD 1 only)
PC Printed
Circuit
5 green
25 bi-color
red/green
Functions:
Silver only
D, F, N, & R
9 yellow
N on-on
15/32"
round hole
P on-off-on
R on-(on)
Terminations
Functions only
WL, WW or QC only
5 1/2"
square hole
S (on)-off-(on)
T on-off-(on)
*UL
None
Option L
L
Beveled frame
adaptor
QC Quick
Connect
L.E.D.
Color
ACTUATORS
1
2
.710
(18.0)
.150
(3.81)
.265
(6.73)
.550
(14.0)
.750
(19.1)
.345
(8.76)
.507
(12.90)
.130
(3.30)
.130
(3.30)
15/32-32
.100
UNS-2A
(2.54)
THD.
TYP.
E4
.020
(0.51)
TYP.
AUGAT Inc.
452 John L. Dietsch Blvd.
Attleboro Falls, MA 02763 USA
(508) 699-9800 FAX (800) 533-2526
How To Order • Rocker/Paddle
TRD Series
TERMINATIONS
(Epoxy seal standard)
WL
QC
WW
Quick Connect
.110" (.020 thick)
Wire Lug
.130
(3.30)
.280
(7.11)
Wire
Wrap
EPOXY
EPOXY
.040 x .080
.080 x
.020
(1.02)W (2.03)L
OBLONG HOLE (2.03)W (0.51) THK.
OBLONG HOLE TYP.
TYP.
Mates with standard
.110" female connectors
.080
(2.03)
Printed Circuit
.590
(15.0)
EPOXY
.160
(4.06)
.160
(4.06)
PC
.095
(2.41)
.030 x .020
(0.76) (0.51)
W.
THK.
.200
(5.08)
1/2" SQUARE CUTOUT SNAP-IN ADAPTOR
5
15/32" HOLE STANDARD
.200
(5.08)
.030
.020
(0.76) x (0.51)
W.
THK.
.018
(0.46)
TYP.
.100
(2.54)
TYP.
Standard TRD bushing will mount in any hole shown below.
Recommended
panel thickness:
.030" to .250"
One hex nut, one internal
tooth lock-washer supplied.
.250
(6.35)
.472
(11.9 )
.472
(11.9)
Recommended panel thickness:
.030" to .125"
.125
(3.17)
Material: bright stainless steel
To specify adaptor separately,
use P/N TRD10793
.400
(10.1)
SLOTTED
.440
(11.1)
FLATTED
.472
(11.9)
.500
(12.7)
CONTACTS/RATING/UL RECOGNITION
1
3
0.4VA Max. @ 20 VDC
Movable Contact:
Fixed Contact/Terminal:
Copper alloy, gold plate
Copper alloy, gold plate
UL
3A Max. @ 125 VAC
Movable Contact:
Fixed Contact/Terminal:
Copper alloy, silver inlay
Copper alloy, silver inlay
For contact option 3
Rating: 3A, 120 VAC(Resistive)
File: E46765
Underwriters Laboratories, Inc. marking
stamped under beveled frame.
L.E.D. ILLUMINATION SINGLE AND BI-COLOR
.508
(12.9)
.508
(12.9)
.750
(19.1)
23°
.150
(3.81)
23°
.265
(6.73)
.150
(3.81)
.150
(3.81)
.070
(1.77)
.820
(20.8)
.377
(9.58)
.740
(18.8)
.755
(19.2)
.715 .840
(18.2) (21.3)
.130
(3.30)
.080
(2.03)
RED
ANODE
.100
(2.54)
TYP.
.200
(5.08)
CATHODE
.025
(.635)
TYP.
L.E.D. Integral
(Rocker Actuator)
All SPDT functions
.006
(.152)
.265
(6.73)
.377
(9.58)
.550
(14.0)
LR
.345
(8.76)
GREEN
CATHODE
COMMON
.100
(2.54)
TYP.
.065
(1.65)
.040
(1.02) 15/32-32 UNS-2A
.078
(1.98)
.080
(2.03)
Standard mounting dimensions apply, L.E.D. supplied in 2 red, 4 yellow, 5 green, or 25 red/green.
L.E.D. Specifications: Max Voltage: 2.8 VDC
Max. Forward Current: red-20mA, Yellow-25 mA, green-25 mA, red/green-40 mA.
Need more technical information?
Consult your local Augat sales office
listed on the back cover
E5
AUGAT Inc.
452 John L. Dietsch Blvd.
Attleboro Falls, MA 02763 USA
(508) 699-9800 FAX (800) 533-2526
E
TRD Series
L
Rocker/Paddle • How To Order
L.E.D. BEVELE FRAME ADAPTOR
MOUNTING
(Accepts rectangular L.E.D.)
15/32" HOLE
STANDARD
1.100
(27.9)
REF.
.200
(5.08)
.225
(5.72)
.213
(5.41)
.500
(12.7)
.213
(5.41)
DIA.
.500
(12.7)
.773
(19.6)
.250
(6.35)
.500
(12.7)
L.E.D.
.550
(14.0)
.050
(1.27)
.500
(12.7)
.472
(12.0)
Material: Nylon 6/6
Color/Finish: Black, matte
E
1/2" SQUARE
CUTOUT
Recommended Panel
Thickness: .030 to .220:
Recommended Panel
Thickness: .030 to .095"
FUNCTIONS
Single
Pole
Double
Pole
123
456
123
456
123
456
D
N
On
None
On
E
P
On
Off
On
F
R
On
None
(On)
G
S
(On)
Off
(On)
H
T
On
Off
(On)
SPDT
Terminals Connected
DPDT
Terminals Connected
2-3
---
1-2
2-3
5-6
-----
1-2
4-5
SWITCH GUARD
None
No mechanical position
Off
Mechanical position,
no electrical connection
(On)
Momentary mechanical position,
electrical connection
ROCKER BOOT SEAL
1. Insert switch in panel.
2. Attach lockwasher and hexnut.
3. Snap switch guard onto switch.
4. Tighten hex hut.
.410
(10.4)
MAX.
.160
(4.06)
SWITCH
GUARD
TRD. SWITCH
1
.760
(19.3)
MAX.
3
2
NUT
.660
(16.7)
MAX.
PANEL
.430
(10.9)
.310
(7.87)
.810
(20.5)
.615
(15.6)
4
Recommended Panel Thickness:
15/32" hole standard - .030 to .220
15/32" square cutout - .030 to .095
Material: Nylon 6/6 Color/Finish: Black matte, Specify separately, P/N TRD10979
E6
To specify boot seal use P/N TRD11494
AUGAT Inc.
452 John L. Dietsch Blvd.
Attleboro Falls, MA 02763 USA
(508) 699-9800 FAX (800) 533-2526
Download