Rocker Switch For Additional Options Refer to Page E4-E6 TRD Series MATERIAL SPECIFICATIONS: TYPICAL PERFORMANCE CHARACTERISTICS: Contacts ................................. Gold over nickel or silver plate Case Material ........................ Polyamide, black matte finish Actuator Material .................. Polyamide Terminals/Fixed Contacts ..... Copper alloy with gold or silver plate Terminal Seal ........................ Epoxy Contact Rating ...................... 0.4 VA Max. @ 20 VDC or peak AC 3 A @ 125 VAC or 28 VDC (2 pos.) 2A Initial Contact Resistance ..... 20 Milliohms max. Contact Timing ..................... Break-before-make Insulation Resistance ............ 1,000 Megohms min. Dielectric Strength ................ 500 Volts RMS @ sea level Actuator Travel ..................... 23° Life Expectancy .................... 2 Pos. - 100,000 actuations 3 Pos. - 50,000 actuations UL recognized under the Component Program of Underwriters Laboratories Inc. File #E46765 ENVIRONMENTAL SPECIFICATIONS: Operating Temperature ......... -4°F to +176°F (-20°C to +80°C) Storage Temperature ............. -49°F to +199°F (-45°C to +93°C) NOTE: When hand soldering, solder with switch in closed position. Solder temperature 550-600°F less than 5 seconds. NOTE: Part numbering sequence page E4 .550 (13.97) .345 (8.76) DPDT .750 (19.1) .508 (12.9) 23° .150 (3.81) Model Type Function .020 (0.51) .100 (2.54) Act. Code Pg. M8 Contact .508 (12.9) .150 (3.81) Terminal Model Type TRD13D1(*)WL TRD13E1(*)WL TRD13F1(*)WL TRD23N1(*)WL TRD23P1(*)WL TRD23R1(*)WL 23° SPDT On None On SPDT On Off On SPDT On None (On) DPDT On None On DP3T On Off On DPDT On None (On) (On) indicates momentary position. 23° .265 (6.73) .070 (1.77) .820 (20.8) .265 (6.73) .150 (3.81) .375 (9.52) .740 (18.8) .715 .840 (21.3) (21.3) .755 (19.2) ANODE Model Type .100 (2.54) TYP. Function CATHODE Act. Code Pg. M8 Contact Terminal Silver Silver Silver Silver Silver Silver Wire Lug Wire Lug Wire Lug Wire Lug Wire Lug Wire Lug SPDT .130 (3.30) .080 (2.03) GREEN CATHODE COMMON .100 (2.54) TYP. .025 (0.64) TYP. Terminal Model .080 (2.03) .040 (1.01) .078 (1.98) .065 (1.65) 15/32-32 UNS-2A TRD11D10WLLR Standard Body and Rocker Color - (Black) Type Function Act. Code Pg. M8 TRD11D10WLLR(*) SPDT On None On 1 Gold Wire Lug TRD13D10WLLR(*) SPDT On None On TRD11E10WLLR(*) SP3T On Off On 5 Gold Wire Lug TRD13E10WLLR(*) SP3T On Off On TRD11F10WLLR(*) SPDT On None (On) 1 Gold Wire Lug TRD13F10WLLR(*) SPDT On None (On) (*) Specify LED color by adding suffix number: (2) Red, (4) Yellow, (5) Green, (25) Red/Green - Bi-color (On) indicates momentary position. Need more technical information? Consult your local Augat sales office listed on the back cover 1 5 1 2 6 2 Contact .006 (0.15) RED .200 (5.08) Act. Code Pg. M8 .345 (8.76) .377 (9.57) .550 (13.8) Function .508 (12.9) .150 (3.81) TRD21N10WL Standard Body Color - (Black) .510 (12.9) 15/32-32 UNS-2A THD. .080 (2.03) TRD11D1(*)WL SPDT On None On 1 Gold Wire Lug TRD11E1(*)WL SPDT On Off On 5 Gold Wire Lug TRD11F1(*)WL SPDT On None (On) 1 Gold Wire Lug TRD21N1(*)WL DPDT On None On 2 Gold Wire Lug TRD21P1(*)WL DP3T On Off On 6 Gold Wire Lug TRD21R1(*)WL DPDT On None (On) 2 Gold Wire Lug (*) Specify rocker color by adding suffix number: (0) Black (2) Red, (6) Blue (9) Yellow, .750 (19.1) .265 (6.73) .130 (3.30) .130 (3.30) .040 .080 (1.02) w x (2.03) OBLONG HOLE TYP. .078 (1.98) E .006 (0.15) E3 1 5 1 Contact Gold Gold Gold Terminal Wire Lug Wire Lug Wire Lug AUGAT Inc. 452 John L. Dietsch Blvd. Attleboro Falls, MA 02763 USA (508) 699-9800 FAX (800) 533-2526 TRD Series Rocker/Paddle • How To Order MATERIAL SPECIFICATIONS: TYPICAL PERFORMANCE CHARACTERISTICS: Movable Contacts ................. Copper alloy w/silver inlay contact or gold plate Terminals/Fixed Contacts ..... Copper alloy w/silver inlay contact or gold plate Terminal Seal ........................ Epoxy Housing/Beveled Frame ....... Polyamide, black matte finish Contact Rating ...................... Silver: 3A max. @ 125 VAC, option 3 Gold: 0.4VA max. @ 20 VDC, option 1 Initial Contact Resistance ..... 20 Milliohms max. Static Withstanding ............... 15KV, per IEC 801-2 Insulation Resistance ............ 1,000 Megohms min. @ 500 VDC Dielectric Strength ................ 500 Volts RMS @ sea level Electrical Life 2 Pos. 20K cycles @ full rated 3A load, 80K @ 0.4VA, 3 pos. 10K cycles @ full rated 3A load, 60K @ 0.4VA ENVIRONMENTAL SPECIFICATIONS: Operating Temperature ......... -4°F to +176°F (-20°C to +80°C) Storage Temperature ............. -49°F to +199°F (-45°C to +93°C) Solder Heat Resistance ......... Meets MIL-STD-202, method 210 *NOTICE: Caution should be used when hand-soldering. Solder heat Resistance -550°-600°F for less than 5 seconds. Solder with the switch in the closed position. UL recognized under the Component Program of Underwriters Laboratories Inc. File #E46765 See pages M2-M4 for application specific indexing. HOW TO ORDER E Model Contact Rating Function TRD1 Single Pole D on-on Single Pole TRD2 Double Pole E F G H on-off-on on-(on) (on)-off-(on) on-off-(on) Actuator 3 Silver 3A Double Pole Terminal 1 Rocker WL Wire Lug 2 Paddle WW Wire Wrap 0 black 2 red 6 blue 1 Gold 0.4VA Actuator Color Mount L.E.D. Illumin. 2 red 4 yellow LR Integral w/rocker (TRD 1 only) PC Printed Circuit 5 green 25 bi-color red/green Functions: Silver only D, F, N, & R 9 yellow N on-on 15/32" round hole P on-off-on R on-(on) Terminations Functions only WL, WW or QC only 5 1/2" square hole S (on)-off-(on) T on-off-(on) *UL None Option L L Beveled frame adaptor QC Quick Connect L.E.D. Color ACTUATORS 1 2 .710 (18.0) .150 (3.81) .265 (6.73) .550 (14.0) .750 (19.1) .345 (8.76) .507 (12.90) .130 (3.30) .130 (3.30) 15/32-32 .100 UNS-2A (2.54) THD. TYP. E4 .020 (0.51) TYP. AUGAT Inc. 452 John L. Dietsch Blvd. Attleboro Falls, MA 02763 USA (508) 699-9800 FAX (800) 533-2526 How To Order • Rocker/Paddle TRD Series TERMINATIONS (Epoxy seal standard) WL QC WW Quick Connect .110" (.020 thick) Wire Lug .130 (3.30) .280 (7.11) Wire Wrap EPOXY EPOXY .040 x .080 .080 x .020 (1.02)W (2.03)L OBLONG HOLE (2.03)W (0.51) THK. OBLONG HOLE TYP. TYP. Mates with standard .110" female connectors .080 (2.03) Printed Circuit .590 (15.0) EPOXY .160 (4.06) .160 (4.06) PC .095 (2.41) .030 x .020 (0.76) (0.51) W. THK. .200 (5.08) 1/2" SQUARE CUTOUT SNAP-IN ADAPTOR 5 15/32" HOLE STANDARD .200 (5.08) .030 .020 (0.76) x (0.51) W. THK. .018 (0.46) TYP. .100 (2.54) TYP. Standard TRD bushing will mount in any hole shown below. Recommended panel thickness: .030" to .250" One hex nut, one internal tooth lock-washer supplied. .250 (6.35) .472 (11.9 ) .472 (11.9) Recommended panel thickness: .030" to .125" .125 (3.17) Material: bright stainless steel To specify adaptor separately, use P/N TRD10793 .400 (10.1) SLOTTED .440 (11.1) FLATTED .472 (11.9) .500 (12.7) CONTACTS/RATING/UL RECOGNITION 1 3 0.4VA Max. @ 20 VDC Movable Contact: Fixed Contact/Terminal: Copper alloy, gold plate Copper alloy, gold plate UL 3A Max. @ 125 VAC Movable Contact: Fixed Contact/Terminal: Copper alloy, silver inlay Copper alloy, silver inlay For contact option 3 Rating: 3A, 120 VAC(Resistive) File: E46765 Underwriters Laboratories, Inc. marking stamped under beveled frame. L.E.D. ILLUMINATION SINGLE AND BI-COLOR .508 (12.9) .508 (12.9) .750 (19.1) 23° .150 (3.81) 23° .265 (6.73) .150 (3.81) .150 (3.81) .070 (1.77) .820 (20.8) .377 (9.58) .740 (18.8) .755 (19.2) .715 .840 (18.2) (21.3) .130 (3.30) .080 (2.03) RED ANODE .100 (2.54) TYP. .200 (5.08) CATHODE .025 (.635) TYP. L.E.D. Integral (Rocker Actuator) All SPDT functions .006 (.152) .265 (6.73) .377 (9.58) .550 (14.0) LR .345 (8.76) GREEN CATHODE COMMON .100 (2.54) TYP. .065 (1.65) .040 (1.02) 15/32-32 UNS-2A .078 (1.98) .080 (2.03) Standard mounting dimensions apply, L.E.D. supplied in 2 red, 4 yellow, 5 green, or 25 red/green. L.E.D. Specifications: Max Voltage: 2.8 VDC Max. Forward Current: red-20mA, Yellow-25 mA, green-25 mA, red/green-40 mA. Need more technical information? Consult your local Augat sales office listed on the back cover E5 AUGAT Inc. 452 John L. Dietsch Blvd. Attleboro Falls, MA 02763 USA (508) 699-9800 FAX (800) 533-2526 E TRD Series L Rocker/Paddle • How To Order L.E.D. BEVELE FRAME ADAPTOR MOUNTING (Accepts rectangular L.E.D.) 15/32" HOLE STANDARD 1.100 (27.9) REF. .200 (5.08) .225 (5.72) .213 (5.41) .500 (12.7) .213 (5.41) DIA. .500 (12.7) .773 (19.6) .250 (6.35) .500 (12.7) L.E.D. .550 (14.0) .050 (1.27) .500 (12.7) .472 (12.0) Material: Nylon 6/6 Color/Finish: Black, matte E 1/2" SQUARE CUTOUT Recommended Panel Thickness: .030 to .220: Recommended Panel Thickness: .030 to .095" FUNCTIONS Single Pole Double Pole 123 456 123 456 123 456 D N On None On E P On Off On F R On None (On) G S (On) Off (On) H T On Off (On) SPDT Terminals Connected DPDT Terminals Connected 2-3 --- 1-2 2-3 5-6 ----- 1-2 4-5 SWITCH GUARD None No mechanical position Off Mechanical position, no electrical connection (On) Momentary mechanical position, electrical connection ROCKER BOOT SEAL 1. Insert switch in panel. 2. Attach lockwasher and hexnut. 3. Snap switch guard onto switch. 4. Tighten hex hut. .410 (10.4) MAX. .160 (4.06) SWITCH GUARD TRD. SWITCH 1 .760 (19.3) MAX. 3 2 NUT .660 (16.7) MAX. PANEL .430 (10.9) .310 (7.87) .810 (20.5) .615 (15.6) 4 Recommended Panel Thickness: 15/32" hole standard - .030 to .220 15/32" square cutout - .030 to .095 Material: Nylon 6/6 Color/Finish: Black matte, Specify separately, P/N TRD10979 E6 To specify boot seal use P/N TRD11494 AUGAT Inc. 452 John L. Dietsch Blvd. Attleboro Falls, MA 02763 USA (508) 699-9800 FAX (800) 533-2526