[1.12 FACTORY SETTINGS] (FCS-)
RDY Term +0.00Hz
MAIN MENU
1 DRIVE MENU
2 ACCESS LEVEL
3 OPEN / SAVE AS
4 PASSWORD
5 LANGUAGE
Code
0A
Quick
ENT
RDY Term +0.00Hz
1 DRIVE MENU
1.1 SIMPLY START
1.2 MONITORING
1.3 SETTINGS
0A
1.4 MOTOR CONTROL
1.5 INPUTS / OUTPUTS CFG
Code <<
1.6 COMMAND
>> Quick
1.7 APPLICATION FUNCT.
1.8 FAULT MANAGEMENT
1.9 COMMUNICATION
1.10 DIAGNOSTICS
1.11 IDENTIFICATION
1.12 FACTORY SETTINGS
1.13 USER MENU
1.14 PROGRAMMABLE CARD
ENT
RUN Term +50.00Hz
80A
1.12 FACTORY SETTINGS
Config. source : Macro-Conf.
PARAMETER GROUP LIST
Goto FACTORY SETTINGS
Save config : No
Code << >> Quick
Power-up
ENT
XXX
Displays the state of the drive
ESC
SIM-
ESC
CON-
ESC
FCS-
ENT
ESC
FACTORY SETTINGS
ESC
LAC-
The [1.12 FACTORY SETTINGS] (FCS-) menu is used to:
• Replace the current configuration with the factory configuration or a previously saved configuration.
All or part of the current configuration can be replaced: select a group of parameters in order to select the menus you wish to load with the selected source configuration.
• Save the current configuration to a file.
248 1755855 12/2009
[1.12 FACTORY SETTINGS] (FCS-)
RUN Term 1250A +50.00Hz
1.12 FACTORY SETTINGS
Config. source : Macro-Conf.
PARAMETER GROUP LIST
Goto FACTORY SETTINGS
Save config : No
Code << >> Quick
ENT
RUN Term 1250A +50.00Hz
Config. Source
Macro-Conf
Config 1
Config 2
Quick
Selection of source configuration
ENT
RUN Term 1250A +50.00Hz
PARAMETER GROUP LIST
All
Drive menu
Settings
Motor param
Comm. menu
Code Quick
Selection of the menus to be replaced
Note: In factory configuration and after a return to "factory settings", [PARAMETER
GROUP LIST] will be empty.
ENT
RUN Term 1250A +50.00Hz
Goto FACTORY SETTINGS
PLEASE CHECK THAT
THE DRIVE WIRING IS OK
ESC=abort ENT=validate
Command to return to "factory settings"
RUN Term 1250A +50.00Hz
Goto FACTORY SETTINGS
First select the parameter group(s)
Press ENT or ESC to continue
This window appears if no group of parameters is selected.
ENT RUN Term 1250A +50.00Hz
Save config
No
Config 0
Config 1
Config 2
Quick
1755855 12/2009 249
[1.12 FACTORY SETTINGS] (FCS-)
Code
FCSI
InI
CFG1
CFG2
FrY-
ALL drM
SEt
MOt
COM
PLC
MOn dIS
GFS nO
YES
SCSI nO
Str0
Str1
Str2
Name/Description
M
Choice of source configuration.
v
(InI) Factory configuration, return to selected macro configuration.
v
(CFG1) v
(CFG2)
If the configuration switching function is configured, it will not be possible to access [Config 1] (CFG1) and
[Config 2] (CFG2) .
M
Selection of menus to be loaded v
(ALL) : All parameters.
v
(drM) : The [1 DRIVE MENU] menu without [1.9 COMMUNICATION] and [1.14
PROGRAMMABLE CARD]. In the[7 DISPLAY CONFIG.]menu, [Return std name] page 262 returns to [No] .
v
(SEt) : The [1.3 SETTINGS] menu without the [IR compensation] (UFr) , [Slip compensation (SLP) and [Mot. therm. current] (ItH) parameters v
(MOt) :motor parameters, see list below.
The following selections can only be accessed if [Config. Source] (FCSI) = [Macro-Conf.] (InI) : v
(COM) : The [1.9 COMMUNICATION] menu without either [Scan. In1 address] (nMA1) to
[Scan. In8 address] (nMA8) or [Scan.Out1 address] (nCA1) to [Scan.Out8 address] (nCA8) .
v
(PLC) : the [1.14 PROGRAMMABLE CARD] menu.
v
(MOn) : the [6 MONITORING CONFIG.] menu.
v
(dIS) : the [7 DISPLAY CONFIG.] menu.
See the multiple selection procedure on page 30 for the integrated display terminal and page 21 for the graphic display terminal.
Note: In factory configuration and after a return to "factory settings", [PARAMETER GROUP LIST] will be empty.
M
It is only possible to revert to the factory settings if at least one group of parameters has previously been selected.
With the integrated display terminal:
- No
- Yes: The parameter changes back to nO automatically as soon as the operation is complete.
With the graphic display terminal: see previous page
M
v
(nO) : v
(Str0) : Press and hold down the "ENT" key for 2 s.
v
(Str0) : Press and hold down the "ENT" key for 2 s.
v
(Str0) : Press and hold down the "ENT" key for 2 s.
The active configuration to be saved does not appear for selection. For example, if it is [Config 0] (Str0) , only
[Config 1] (Str1) and [Config 2] (Str2) appear. The parameter changes back to [No] (nO) as soon as the operation is complete.
[Rated motor power] (nPr) - [Rated motor volt.] (UnS) - [Rated mot current] (nCr) [Rated motor freq.] (FrS) [Rated motor speed] (nSP) -
[Auto tuning] (tUn) [Auto tuning status] (tUS) [U0] (U0) to [U5] (U5) - [F1] (F1) to [F5] (F5) - [V. constant power] (UCP) - [Freq. Const
Power] (FCP) - [Nominal I sync] (nCrS) - [Nom motor spdsync] (nSPS) - [Pole pairs.] (PPnS) - [Syn. EMF constant] (PHS) - [Autotune L daxis] (LdS) - [Autotune L q-axis] (LqS) - [Cust. stator R syn] (rSAS) - [IR compensation] (UFr) - [Slip compensation] (SLP) - motor parameters that can be accessed in [Expert] mode page 75 .
[Mot. therm. current] (ItH)
1.
[Config. Source] (FCSI) = [Macro-Conf] (InI)
2.
[PARAMETER GROUP LIST] (FrY-) = [All] (ALL)
3.
[Goto FACTORY SETTINGS] (GFS = YES)
250 1755855 12/2009