[1.12 factory settings] (fcs-)

advertisement

[1.12 FACTORY SETTINGS] (FCS-)

With graphic display terminal:

RDY Term +0.00Hz

MAIN MENU

1 DRIVE MENU

2 ACCESS LEVEL

3 OPEN / SAVE AS

4 PASSWORD

5 LANGUAGE

Code

0A

Quick

ENT

RDY Term +0.00Hz

1 DRIVE MENU

1.1 SIMPLY START

1.2 MONITORING

1.3 SETTINGS

0A

1.4 MOTOR CONTROL

1.5 INPUTS / OUTPUTS CFG

Code <<

1.6 COMMAND

>> Quick

1.7 APPLICATION FUNCT.

1.8 FAULT MANAGEMENT

1.9 COMMUNICATION

1.10 DIAGNOSTICS

1.11 IDENTIFICATION

1.12 FACTORY SETTINGS

1.13 USER MENU

1.14 PROGRAMMABLE CARD

ENT

RUN Term +50.00Hz

80A

1.12 FACTORY SETTINGS

Config. source : Macro-Conf.

PARAMETER GROUP LIST

Goto FACTORY SETTINGS

Save config : No

Code << >> Quick

With integrated display terminal:

Power-up

ENT

XXX

Displays the state of the drive

ESC

SIM-

ESC

CON-

ESC

FCS-

ENT

ESC

FACTORY SETTINGS

ESC

LAC-

The [1.12 FACTORY SETTINGS] (FCS-) menu is used to:

• Replace the current configuration with the factory configuration or a previously saved configuration.

All or part of the current configuration can be replaced: select a group of parameters in order to select the menus you wish to load with the selected source configuration.

• Save the current configuration to a file.

248 1755855 12/2009

[1.12 FACTORY SETTINGS] (FCS-)

RUN Term 1250A +50.00Hz

1.12 FACTORY SETTINGS

Config. source : Macro-Conf.

PARAMETER GROUP LIST

Goto FACTORY SETTINGS

Save config : No

Code << >> Quick

ENT

RUN Term 1250A +50.00Hz

Config. Source

Macro-Conf

Config 1

Config 2

Quick

Selection of source configuration

ENT

RUN Term 1250A +50.00Hz

PARAMETER GROUP LIST

All

Drive menu

Settings

Motor param

Comm. menu

Code Quick

Selection of the menus to be replaced

Note: In factory configuration and after a return to "factory settings", [PARAMETER

GROUP LIST] will be empty.

ENT

RUN Term 1250A +50.00Hz

Goto FACTORY SETTINGS

PLEASE CHECK THAT

THE DRIVE WIRING IS OK

ESC=abort ENT=validate

Command to return to "factory settings"

RUN Term 1250A +50.00Hz

Goto FACTORY SETTINGS

First select the parameter group(s)

Press ENT or ESC to continue

This window appears if no group of parameters is selected.

ENT RUN Term 1250A +50.00Hz

Save config

No

Config 0

Config 1

Config 2

Quick

1755855 12/2009 249

[1.12 FACTORY SETTINGS] (FCS-)

Code

FCSI

InI

CFG1

CFG2

FrY-

ALL drM

SEt

MOt

COM

PLC

MOn dIS

GFS nO

YES

SCSI nO

Str0

Str1

Str2

Name/Description

M

[Config. Source]

Choice of source configuration.

v

[Macro-Conf]

(InI) Factory configuration, return to selected macro configuration.

v

[Config 1]

(CFG1) v

[Config 2]

(CFG2)

If the configuration switching function is configured, it will not be possible to access [Config 1] (CFG1) and

[Config 2] (CFG2) .

M

[PARAMETER GROUP LIST]

Selection of menus to be loaded v

[All]

(ALL) : All parameters.

v

[Drive menu]

(drM) : The [1 DRIVE MENU] menu without [1.9 COMMUNICATION] and [1.14

PROGRAMMABLE CARD]. In the[7 DISPLAY CONFIG.]menu, [Return std name] page 262 returns to [No] .

v

[Settings]

(SEt) : The [1.3 SETTINGS] menu without the [IR compensation] (UFr) , [Slip compensation (SLP) and [Mot. therm. current] (ItH) parameters v

[Motor param]

(MOt) :motor parameters, see list below.

The following selections can only be accessed if [Config. Source] (FCSI) = [Macro-Conf.] (InI) : v

[Comm. menu]

(COM) : The [1.9 COMMUNICATION] menu without either [Scan. In1 address] (nMA1) to

[Scan. In8 address] (nMA8) or [Scan.Out1 address] (nCA1) to [Scan.Out8 address] (nCA8) .

v

[Prog. card menu]

(PLC) : the [1.14 PROGRAMMABLE CARD] menu.

v

[Monitor config.]

(MOn) : the [6 MONITORING CONFIG.] menu.

v

[Display config.]

(dIS) : the [7 DISPLAY CONFIG.] menu.

See the multiple selection procedure on page 30 for the integrated display terminal and page 21 for the graphic display terminal.

Note: In factory configuration and after a return to "factory settings", [PARAMETER GROUP LIST] will be empty.

M

[Goto FACTORY SETTINGS]

It is only possible to revert to the factory settings if at least one group of parameters has previously been selected.

With the integrated display terminal:

- No

- Yes: The parameter changes back to nO automatically as soon as the operation is complete.

With the graphic display terminal: see previous page

M

[Save config]

v

[No]

(nO) : v

[Config 0]

(Str0) : Press and hold down the "ENT" key for 2 s.

v

[Config 1]

(Str0) : Press and hold down the "ENT" key for 2 s.

v

[Config 2]

(Str0) : Press and hold down the "ENT" key for 2 s.

The active configuration to be saved does not appear for selection. For example, if it is [Config 0] (Str0) , only

[Config 1] (Str1) and [Config 2] (Str2) appear. The parameter changes back to [No] (nO) as soon as the operation is complete.

List of motor parameters

[1.4 MOTOR CONTROL] (drC-) menu:

[Rated motor power] (nPr) - [Rated motor volt.] (UnS) - [Rated mot current] (nCr) [Rated motor freq.] (FrS) [Rated motor speed] (nSP) -

[Auto tuning] (tUn) [Auto tuning status] (tUS) [U0] (U0) to [U5] (U5) - [F1] (F1) to [F5] (F5) - [V. constant power] (UCP) - [Freq. Const

Power] (FCP) - [Nominal I sync] (nCrS) - [Nom motor spdsync] (nSPS) - [Pole pairs.] (PPnS) - [Syn. EMF constant] (PHS) - [Autotune L daxis] (LdS) - [Autotune L q-axis] (LqS) - [Cust. stator R syn] (rSAS) - [IR compensation] (UFr) - [Slip compensation] (SLP) - motor parameters that can be accessed in [Expert] mode page 75 .

[1.3 SETTINGS] (SEt-) menu:

[Mot. therm. current] (ItH)

Example of total return to factory settings

1.

[Config. Source] (FCSI) = [Macro-Conf] (InI)

2.

[PARAMETER GROUP LIST] (FrY-) = [All] (ALL)

3.

[Goto FACTORY SETTINGS] (GFS = YES)

250 1755855 12/2009

Download