HRC cartridge fuses 133 08 153 96 120 04 130 08 140 12 151 50 Technical data and dimensions (p. 135 to 137) Pack Cat.Nos Cylindrical type gG Pack Cat.Nos Conform to EN 60269-1, IEC 60269-1 and 2 Veritas approved 8 x 32 (previously 8.5 x 31.5) Conform to EN 60269-1, IEC 60269-1, and 2 Veritas approved 8 x 32 (previously 8.5 x 31.5) Without indicator 10 10 10 10 10/100 10 10/100 10 10 10 10 10 10 10 10 10 10 123 01 123 02 123 04 123 06 123 10 With indicator 124 02 124 04 124 06 123 16 124 10 124 16 Without indicator With indicator 133 94 133 01 133 02 133 04 133 06 133 08 133 10 133 16 133 20 133 25 134 02 134 04 134 06 134 08 134 10 134 16 134 20 134 25 Without striker With striker 10 10 10 10 10 10 10 10 143 06 143 10 143 16 143 20 143 25 143 32 143 40 143 50(1) 145 16 145 20 145 25 145 32 145 40 145 50(1) Without striker With striker 10 10 10 10 10 10 10 10 10 10 153 16 153 20 153 25 153 32 153 40 153 50 153 63 153 80 153 96 153 97(1) 155 50 155 63 155 80 155 96 155 97(1) Rating (Amps) 1 2 4 6 10 10 16 10 x 38 HRC 0.5 1 2 4 6 8 10 16 20 25 14 x 51 HRC 6 10 16 20 2 32 40 50 22 x 58 HRC 16 20 25 32 40 50 63 80 100 125 Voltage ± (Volts) 400 Rupture capacity (Amps) 20000 Without indicator 10 10 10 10 Rating (Amps) 120 04 120 06 120 08 120 10 4 6 8 10 Without indicator 500 500 500 400 Cylindrical type aM (motor rated) 100000 100000 100000 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 x 38 HRC 0.50 1 2 4 6 8 10 12 16 20 25 130 95 130 01 130 02 130 04 130 06 130 08 130 10 130 12 130 16 130 20(2) 130 25(2) Without striker With striker 140 10 140 12 140 16 140 20 140 25 140 32 140 40 140 50(1) 141 02 141 04 141 06 141 08 141 10 141 12 141 16 141 20 141 25 141 32 141 40 141 50(1) Without striker With striker 150 25 150 32 150 40 150 50 150 63 150 80 150 96 150 97 151 25 151 32 151 40 151 50 151 63 151 80 151 95 151 97 14 x 51 HRC 2 4 6 8 10 12 16 20 25 32 40 50 22 x 58 HRC 25 32 40 50 63 80 100 125 Voltage ± (Volts) Rupture capacity (Amps) 400 500 20000 100000 400 400 500 100000 400 500 100000 400 Neutral links 10 10 10 10 123 00 133 00 143 00 153 00 8 x 32 (previously 8.5 x 31.5) 10 x 38 14 x 51 22 x 58 Isolating fuse carriers 8.5 x 32 and 10 x 38 (p. 167) (1) Overrating described by standards (2) Overrating not described by standards Bold pack quantities: Minimum quantities to be ordered 132 cartridge fuses Size 0 to 4 (continued) Single pole with micro-switch n Bases for blade type (p. 133) Size 00 4 10 Ø7.5 D 7.5 7.5 O Ø15.5 P F E H 57 C 6.3 10 13 16 84 B 31.5 38 51 58 120 A 8.5 10.3 14.3 22.2 25 Size (mm) 8 x 32 10 x 38 14 x 51 22 x 58 100 C D M8 A 57.5 36 D R C Single pole Cat.Nos 160 01 - 162 00 A S B G B n HRC cylindrical (p. 132) N M 37.5 I 20 39 L Q n Blade type (p. 134) Triple pole Cat.Nos 160 05 - 162 04 D1 M 102 F 57 84 25 K N H 100 L E Ø15.5 120 Ø7.5 I J 68 Sizes 0 to 4 Single pole without micro-switch J C K 1 200 175 72 25 30 25 150 80 28 68 35 46 38 13.5 20 10.5 10 85 215 2 225 200 78 30 30 25 170 80 32 83 35 58 39 13.5 20 10.5 10 90 229 3 250 210 91 41 30 25 158 83 35 92 35 68 40 14 20 10.5 12 94 242 4 320 270 114 51 45 30 220 98 50 125 40 93 40 14 28 13 16 105.5 280 Size 0 - 1 - 2 Triple pole F N 0 171 150 63 20 25 125 75 23 68 24 43 28 11.5 14 7.5 8 75 198 C D E M 25 Note: Force of striker at the beginning of stroke 1.9 kg and 1 kg at the end according to NF C 63-213 57.5 G 4 200 61 78 90 77 107 14 2.5 60 8 27 14.5 119 10 23 P 3 150 61 75 70 64 75 14 2.5 36 6 23 14.5 88 10 18 O 2 150 64 74 50 50 60 14 3 28 6 19 14.5 72 10 14.5 Q 1 135 64 74 47 47 52 14 3 21 6 16 14.5 64 10 14.5 H 0 125 62 67 36 39 46 14 2.5 15 6 14.5 14.5 59 10 14.5 I 00 78 44 52 30 46 2.5 15 6 59 10 14.5 S Size (mm) A B C D1 D2 E F G H I J K L M N Size (mm) A B C D E F G H I J K L M N O P Q R S B A A J K 37.5 51.5 20 10 6 M8 G L A D2 C B D R n Removable handle (p. 133) 23 124 83 Size (mm) A B C D E F G H I J K L M N O P Q R S 0 171 150 47 20 25 125 75 23 68 24 43 28 11.5 14 7.5 8 96 180 1 200 175 59 25 30 25 150 80 28 68 35 46 38 13.5 20 10.5 10 107 224 2 225 200 67 30 30 25 170 80 32 83 35 58 39 13.5 20 10.5 10 121 240 3 250 210 82 41 30 25 158 83 35 92 35 68 40 14 20 10.5 12 110 266 4 320 270 114 51 45 30 220 98 50 125 40 93 40 14 28 13 16 138 336 B Size (mm) A B C D B 0 171 48 144 67 1 200 62.5 180 81 2 225 68 204 93 135 selection charts upstream n How to select a protection system ? n Example of good selection upstream ∫i2 dt in A2 sec. Depending on the type of failure, overload or short-circuit, use 2 series of data ① Overloads: use the operating zone curves of the different protection devices. On the same row, the operating zones should not overlap cartridge upstream cartridge upstream downstream cartridge downstream ② Short-circuits: use the ∫i t tables. The total ∫i t of the protection 2 2 system the furthest downstream must be less than the upstream protection pre-arc ∫i2t downstream cartridge downstream C.T. pre-arc C.T. arc 230 V cos C.T. arc 500 V cos C.T. pre-arc C.T. arc 230 V cos C.T. arc 500 V cos n Selection between cartridge fuses (according to IEC 60269-2-1) Downstream maximum rating determined according to class and voltage to obtain selection aM gG Upstream rating gG cartridge fuse (A) 2 4 6 8 10 12 16 20 25 32 35 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1 2 2 2 2 4 6 8 10 12 12 16 20 25 36 40 63 80 125 125 160 200 250 315 400 500 = 0.1 = 0.1 Downstream maximum rating determined according to class and voltage to obtain selection aM gG Upstream rating aM cartridge fuse (A) 1 2 2 4 4 6 10 16 20 20 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 = 0.1 = 0.1 2 4 6 8 10 12 16 20 25 32 36 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1 2 2 4 6 6 10 12 12 20 20 25 25 40 50 63 80 100 125 160 200 250 315 400 500 630 1 4 6 8 10 12 16 20 25 32 32 32 40 50 63 80 100 125 160 160 200 250 315 400 500 500 1250 800 630 n Motor protection Motor three-phase 400 V 230 V kW 0.37 0.75 1.1 1.8 2.2 3 4 5.5 7.5 10 11 15 18.5 22 25 30 45 55 75 80 90 110 132 160 220 Hp kW 0.37 0.5 1.8 0.75 1 3.5 1.5 1.5 4.4 2.2 2.5 7 3 3 8.7 4 4 11.5 5.5 5.5 14.3 7.5 7.5 20 11 10 27 15 13.5 35 18.5 15 39 22 20 52 25 25 64 30 30 75 37 35 85 45 40 103 55 60 147 75 75 182 90 100 239 110 160 260 132 125 295 160 150 356 200 180 425 250 218 520 315 300 710 400 (1) 400 V max. 136 In A Hp 0.5 1 2 3 4 5.5 7.5 10 15 20 25 30 34 40 50 60 75 100 125 150 180 218 270 340 430 550 In A kW 1.03 0.75 2 1.5 3.5 2.2 5 3.7 6.6 4 8.5 5.5 11.5 7.5 15.5 11 22 15 30 18.5 37 25 44 30 51 40 60 45 72 51 85 63 105 80 138 110 170 132 205 160 245 220 300 370 250 475 335 584 450 750 500 500 V Hp 1 2 3 5 5.5 7.5 10 15 20 25 34 40 54 60 70 109 110 150 180 220 300 In A 1.5 2.6 3.8 5.9 6.5 9 12 18.4 23 28.5 39.4 45 60 65 75 89 112 156 187 220 310 340 450 610 680 360 472 608 680 10 x 38 ratings gG aM 4 2 6 4 8 4 12 6 16 8 20 10 25 12 20(1) 20(1) 14 x 51 22 x 58 ratings ratings gG aM gG aM 4 2 6 4 8 4 12 6 16 8 16 20 10 20 25 12 25 32 20 32 20 50 25 50 25 32 50 32 40 63 40 50 50(1) 80 100 63 80 80 100 125(1) S. 00 ratings gG aM 25 32 50 50 63 80 100 125 125 160 20 25 32 40 50 63 80 80 100 125 Cartridges S. 0 ratings gG aM 63 80 100 125 125 160 200 63 80 80 100 125 160 S. 1 ratings gG aM 125 125 160 200 250 125 160 200 250 S. 2 ratings gG aM 200 250 315 400 S. 3 ratings gG aM S. 4 ratings gG aM 200 250 315 315 400 500 630 800 blade cartridge fuses gG and aM types The gG or aM types protect the conductors of electrical circuits in the event of overbad or short-circuit gG cartridge fuses: The selectivity ratio is 1.6 instead of 2 The breaking capacity of 120000 A provides full protection in the most critical situations aM cartridge fuses: These cartridge fuses must be combined with a low-overload thermal protection device The breaking capacity of 100000 A from size 10 x 38 upwards provides full protection in the most critical situations Cylindrical industrial cartridge fuses can be used to protect DC circuits supplied at up to 48 V max. n Rupture capacity curves aM type 25 32 35 40 50 63 80 Times in seconds 10 000 100 125 160 200 250 315 400 500 630 800 1 000 1 250 gG type 10 000 1 000 1 000 Time in seconds 10 000 10 000 1 000 1 000 100 100 100 10 10 10 10 1 1 1 1 0.1 0.1 0.01 1 10 100 1 000 Current in Amps 0.01 100 000 10 000 ∫ 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 100 0.1 0.1 0.01 1 10 100 1 000 Current in Amps 10 000 0.01 100 000 n Thermal stresses ( I2dt) gG type (for 500 V±) aM type for 500 V± - except 1250 A for 400 V 10 000 000 10 000 000 Thermal stress in A s 1 000 000 2 1 000 000 2 Thermal stress in A s 100 000 10 000 1 000 100 25 32 35 40 50 63 80 125 200 100 160 250 Rating in Amps 315 400 500 100 000 10 000 1 000 800 1250 1000 630 100 Total maximum thermal stress for critical current Pre-arc thermal stress for critical current 1 250 1 000 800 630 500 400 315 250 200 160 125 100 80 63 50 40 32 25 Limited currents at peak kA 30 10 3 f 1 0.3 0.1 0.1 0.2 0.5 1 2 5 10 Prospective short-circuit at kA rms 63 50 80 100 160 250 400 630 1000 125 200 315 500 800 Rating in Amps n Consumption in watts when hot, at rated current 100 Ief 40 32 n gG(1) type limitation curve 2.5 25 20 (1) For aM cartridge fuses, see technical data sheets in the Legrand e-catalogue 50 100 Fuse ratings (A) 25 32 35 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 Cartridge fuses gG Size 00 2.1 3 3 3.3 4.5 6 7 7.5 13 15 aM Size 0 to 4 4.2 5.5 6.5 8.5 9.5 12 15 19 23 24 33 36 45 51 77 80 Size 00 1.3 1.8 2.5 3 3.6 5.2 6 7 Size 0 to 4 3.9 5.5 6.5 8.5 11.5 13.5 17 24 28 34 41 49 70 75 137