INVISILED™ Tape Lights Installation Instructions Certifications E204239 239346 WAC INVISILED™ Tape Lights, power supplies, and accessories are all UL and CSA Listed. Key specifications Overall dimensions Min./ max. run length Colors Power Supply Current Power consumption LED spacing Field cutting unit length Beam angle Lumen output 7/16” x 1/8” (10mm x 2.8mm) 1 foot, 5 feet, or 2 inches long 5 ft / 25 ft per run White (3500K), Amber, Blue, Green, Red 12V AC/DC, Class II 200 mA/ft 2.0 Watts/ft 1 inch Every inch on indicators (cut only at the end of a run) 120º 90 lm/ft (White); 22 lm/ft (Amber); 20 lm/ft (blue); 60 lm/ft (Green); 35 lm/ft (Red) Intended Applications • • • • • • • • • • INVISILED™ Tape Lights are water resistant. Intended for indoor use. Dry and damp locations. The recommended ambient environment is −4ºF to 122ºF, and relative humidity up to 95%. Refrigerated food or beverage cabinets Bar and counter accent Under cabinet task lighting Toe kick accent lighting Display cases and windows Trade show booths Architectural coves Audio/Visual accents Installation Instructions • INVISILED™ must be at room temperature ( 50ºF or above ) for installation. • To prepare INVISILED™ for installation, carefully join pieces together on a flat surface. Turn the power on for 15 mins or until INVISILED™ is flexible. • INVISILED™ Tape Lights have no polarity for connection. Connectors may be used interchangeably. • If a 1/2”x1/2” or greater cove or channel is not builtin, a Retrofit Channel may be necessary to conceal the tape lights or provide an extended surface for mounting or directing the light. Please refer to installation diagrams shown on page 2. • STEP 1: Determine the number of separately powered runs needed. Calculate the number of drivers. • STEP 2: Measure the length of each run and round it off to the nearest 2-inch interval. Determine the necessary quantities of 1-ft, 5-ft, and 2-in sections. • STEP 3: Count the number of right angle turns in the runs. • STEP 4: If making lateral turns at angles other than 90°, determine the number of short joiner cables necessary to make the lateral adjustment. • STEP 5: Determine the number of sections that require jumping, powered by the same driver. • STEP 6: Power the transformers and connect the male and female ends, to form straight lines or bend lengthwise around the installation surface. • STEP 7: Connect remaining sections using 1-ft, 5-ft and 2in sections of tape light or connectors. INVISILED™ sections may be cut where indicated at the end of the run only. • STEP 8: On smooth surfaces, the included adhesive is sufficient in most applications. However if mounting surface is a porous or textured surface, then use a Mounting Clip every 6 inches to reinforce the installation. • STEP 9: Terminate each separately powered run with an end cap. Cut end caps or male end caps are the available choices for cut or uncut sections respectively. • NOTE: Tape may be cut to length as indicated by the markings on the back of the INVISILED™® section. Cut sections may not be rejoined to start a new section and must be sealed with silicon after adding an end cap. Retain these instructions for future service and adjustments 615 South Street, Garden City, NY 11530 Tel: (516) 515-5000 Fax (516) 515-5050 www.waclighting.com Caution – To prevent the risk or fire. Do not install closer than 1/2 inches to the cabinet wall(s) or in a compartment smaller than 14-7/16 in by 14-7-16 in by 12 in General installation Suggestions L connector is used for connecting tape light at right angle of 90º. May be used interchangeably for left or right turns. 2-inch joiner cables and 2-inch tape lights may be used together for making lateral curves. 6-inch, 12-inch, or 6-foot joiner cables are used for connecting separate sections in a single run. Mounting clips are used for surfaces that are difficult to adhere to. Retrofit channels may be used to create coves or extend light baffles to control light output direction or glare. The channel has a (5/64 Inch) slot every inch on one side allowing curves at radii of 6 inches or greater. Retrofit channels may be painted to match the architecture.