Cable Solutions Cables according to NEC, NFPA 79 and UL 508A standards Welcome to LÜTZE Cable Solutions Connectivity Solutions Cabinet Solutions Control Solutions Transportation Solutions Efficiency in Automation - A reflection of our company philosophy As an experienced specialist in automation technology, with solutions for flexible and high flexing cables, cable assemblies, interfaces, current control and cabinet wiring, we have had a focus on efficiency for many years. LÜTZE defines Efficiency in Automation as the use of sustainable products and solutions to further increase the performance of our products in our customers applications. We realise this by using components for highly efficient control systems, products with above average life cycles and raising energy efficiency in control cabinets by means of the LSC wiring system. Efficiency in Automation reflects our efforts in striving for efficient working relationships with our customers: in a medium sized family owned company we have short communcation channels and a high level of manufacturing competence. The value of a product or a solution from LÜTZE is determined by its sustainable qualities. Every innovation will only be successful in the future if it has a long term positive effect. Therefore, we provide long lasting as well as highly efficient components. Thus LÜTZE creates value through efficiency. LÜTZE provides answers and demonstrates how to handle resources responsibly, with our environment and our future in mind. LÜTZE - Efficiency in Automation For more information on our solutions, please visit www.luetze.com Business Management: Sustainable and forw a The future is blue Sustainable enterprise means thinking and planning ahead, understanding and embedding the belief that long lasting success is more important than short-term profit maximisation. This is an attitude that has existed within LÜTZE for quite some time. Economic and environmental responsibilities complement each other well and are reflected in the sustainable management and product policy - and from now in the SkyBLUE campaign. We manufacture our products in a resourceful and energy-conscious manner. We use long lasting, environmentally-friendly materials. And our products, in turn, help our customers save energy and resources. Good for everyone: for us, for the environment, for our customers a win-win-win situation. : w ard-looking „The competitiveness of our industry and of its suppliers depends quite substantially on how we succeed in developing practical results. The results that we produce together today, are our competitive advantages in the future.“ Udo Lütze, Member of the Executive Committee of the Green Carbody Innovation Alliance Goods with real value The value of a product or a solution from LÜTZE is determined by its sustainable qualities as well. Every innovation is only as successful in the future if it has a long-term positive effect. Therefore, we provide long lasting as well as highly efficient components. We are incorporating the necessary knowledge and manufacturing competence in numerous joint projects with the objective of improving energy efficiency and sustainable technologies and industries. Thus, LÜTZE provides answers and demonstrates how to handle resources responsibly, with our environment and our future in mind. How North American codes and standards affect your choice of cables NEC, NFPA 79 and UL 508A The National Electrical Code (NEC) sible that different States are on dif- red to as NFPA 70. This code vary from State to State. Once a is providing rules and regulation for electrical applications. It also refercovers the electrical installation for many areas such as public and private premises, buildings etc. The NEC is created and updated every three years by a technical committee consisting of NFPA members and industry experts. It is pos- ferent versions of the NEC as the timeframe to adopt a new code may State adopted the NEC it becomes USA. It covers the electric or elec- the use of listed cables or cords for volts or less. The NFPA 79 standard a rule that must be followed. The NEC will only recognize and allow field wiring connections. NFPA 79 is the electrical standard for industrial machinery in the tronic equipment of electrical machinery from a nominal voltage of 600 has provisions regarding wiring practices that represent best practi- ce. NFPA 79 makes reference to UL NEC - Regulates the field level NFPA 79 - Regulates the machine level UL 508A - Regulates the cabinet level Listed cable but has a special provision for “recognized component wiring” in article 12.9. UL 508A is a standard for industrial control panels covering the enclosure as well as the panel in applicati- ons operating from a voltage of 600 volts or less. UL 508A makes reference to UL Listed cable but has a special provision for “recognized component wiring” in article 29.2. Codes and standards are not the same. A standard represents a principle or a model in how something is being done. You could call it a “best practice”. Standards are also defined as a level of quality or attainment and allow comparative evaluations. A code goes a step further and represents a law or regulation that must be followed when it is given statutory force. The NEC is not federal law but is enforced by adoption by state or municipality. Electrical wiring in the USA is regulated by the National Electric Code also referred to in short as the NEC. The NEC will make a reference to many different standards. Approvals for North America Product certifications in North America will often be conducted by the National Recognized Testing Laboratories (NRTL). The NRTLs are determined by the Occupational Safety and Health Administration (OSHA). You can find a list of the current NRTLs on www.osha.gov. LÜTZE mainly uses Underwriters Laboratories (UL) to certify the products. UL (USA) and CSA (Canada) have an agreement that allows the usage of one certification for both USA and Canada. In general there are two main certification classes: Certification UL Recognized Logos UL Listed Common „UL Listings“ for industrial cables: Meaning „UL Recognized“ signifies that the product is rated as a component. A component is a part of an application. Cables with an „Appliance Wiring Material“ (AWM per Standard 758) are always „recognized“. Typically these cables are already installed on the machine when it ships. „UL Listed“ signifies a cable as actually tested and proven for a specific use. This way the cable has to match the UL Standards and the requirements of the National Electric Code (NEC). Typically, cables with a UL Listing are used for field wiring in North America. UL Listing type CM CMG CMX PLTC PLTC-ER Description Meaning Communication Cables for data communication per UL category DUZX and NEC 800 Communication General Cables for data communication per UL category DUZX and NEC 800 Communication Residential Cables for data communication with restrictions per UL category DUZX and NEC 800 Power Limited Tray Cable Cables for tray applications per UL category QPTZ and NEC 725 Power Limited Tray Cable Cables for tray applications per UL category QPTZ and NEC 725 (exposed use possible) Exposed Run ITC Instrumentation Tray Cable Instrumentation cables for tray applications per UL category NYTT and NEC 727 ITC-ER Instrumentation Tray Cable Instrumentation cables for tray applications per UL category NYTT and NEC 727 (exposed use possible) Exposed Run TC Power and Control Tray Cable Power and control cables for tray applications per UL category QPOR and NEC 336 TC-ER Power and Control Tray Cable Power and control cables for tray applications per UL category QPOR and NEC 336 (exposed use possible) Exposed Run MTW Machine Tool Wire Single or multi conductor control cables for Machine Tool Wiring per UL category ZKHZ and NEC 670 Flexible VFD and Servo Flexible VFD and Servo aka Power cables for motor and variable frequency drive applications per UL category ZJFH Flexible Motor Supply Cable WTTC Wind Turbine Tray Cable Power and control cables for wind turbine applications per UL category ZGZN This list only shows the common UL Listings for typical applications in the field of automation and does not stand for a complete overview of the current UL Listings. It is possible to combine different UL Listings in one cable. LÜTZE offers a variety of cables with UL Listings for various industrial applications. Use of certifications: Code / Standard NEC NFPA 79 UL 508A Use Field level Machine level Cabinet level Permissible cables UL Listed only UL Listed and/or UL Recognized if in compliance with NFPA 79 12.9 UL Listed and/or UL Regognized if in compliance with UL 508a 29.2 In order to use recognized AWM type cable in compliance with NFPA 79 paragraph 12.9 or UL 508A paragraph 29.2 the machine builder must assure and document, that the selected cable is suitable for the application. The suitability can be checked easily by matching the UL AWM style to the application. The UL AWM styles provide, among other things, information about the materials and wall thickness of a cable. Example: AWM 2587 describes a 600V 90°C cable with PVC jacket for external wiring. The actual use, for example, may not exceed the rated voltage of this cable. Typical rated voltages for AWM cables are 30, 300, 600 and 1000V. Ampacity per National Electric Code (USA) Calculation of the max. ampacity, based on “NEC 2014 Edition” According to NEC Tabelle 310.15(B), Edition 2014 Allowable Ampacities of Insulated Conductors Rated 0 Through 2000 Volts, 60 °C – 90 °C (140 °F – 194 °F). Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30 °C (86 °F) Temperature Rating of Conductor 60 °C / 140 °F 75 °C / 167 °F 90 °C / 194 °F Types TBS, SA, SIS, FEP, FEPB, MI, RHH, RHW-2, THHN, THHW, THW-2, THWN-2, USE-2, XHH, XHHW, XHHW-2, ZW-2 Types RHW, THHW, THW, THWN, XHHW, USE, ZW Size AWG oder kcmil COPPER 18 – – 16 – – 14** 15 20 12** 20 25 10** 30 35 8 40 50 6 55 65 4 70 85 3 85 100 2 95 115 1 110 130 1/0 125 150 2/0 145 175 3/0 165 200 4/0 195 230 * Refer to NEC 310.15(B)(2) for the ampacity correction factros where the ambiente temperature is other than 30 °C / 86 °F * Refer to NEC 240.4(D) for conductor overcurrent protection limitations. Types TW, UF 14 18 25 30 40 55 75 95 115 130 145 170 195 225 260 Correction Factors Ambient temperature (Based on 310.15(B)(2)(a)) For ambient temperatures other than 30 °C / 86 °F, multiply the allowable ampacities shown above by the appropriate factor shown below. Ambient temperature 60 °C / 140 °F 75 °C / 167 °F 90 °C / 194 °F 21-25 °C / 70-77 °F 1.08 1.05 1.04 26-30 °C / 78-86 °F 1 1 1 31-35 °C / 87-95 °F 0.91 0.94 0.96 36-40 °C / 96-104 °F 0.82 0.88 0.91 41-45 °C / 105-113 °F 0.71 0.82 0.87 46-50 °C / 114-122 °F 0.58 0.75 0.82 51-55 °C / 123-131 °F 0.41 0.67 0.76 56-60 °C / 132-140 °F – 0.58 0.71 61-70 °C / 141-158 °F – 0.33 0.58 71-80 °C / 159-176 °F – – 0.41 Number of current carrying conductors Per NEC Table 310.15(B)(3)A Adjustment Factors for more than three current carrying conductors in Raceway or cable. Number of Current-Carrying Conductors Percent of values in tables 310.15(B) through 310.15(B)(19) as adjusted for ambient temperature if necessary 1-3 100 4-6 80 7-9 70 10-20 50 21-30 45 31-40 40 41 and more 35 Number of conductors Is the total number of conductors in the raceway or cable adjusted in accordance with 310.15(B)(5) and (6) Example: Calculation of 80 °C PUR AWG12 motor supply cable with control pair at ambient temperature of 50 °C and a required ampacity of 12,5 Ampere 1. Factor ambient temperature 2. Factor current carrying conductors 0,75 80 → 25 A x 0,75 x 0,8 = 15 A > 12,5 A Our recommendation AWG12 (equals ca. 4 mm2) Note: The given values are reference numbers to calculate the required cable sizes. Friedrich Lütze GmbH is not responsible for the conformity of the values provided by the NEC. PVC control cables · unshielded LÜTZE SILFLEX® N PVC CONTROL TRAY CABLE With approvals for North America according to NEC, NFPA 79 and UL 508A Use of certifications / Einsatz der Zulassungen Code / Standard NEC NFPA 79 UL 508A Use / Einsatz Field level / Feldebene Machine level / Maschinenebene Cabinet level / Schaltschrankebene Application • Multi-conductor control cables with TC-ER „Exposed Run“ approval • Machine and device construction, transport and conveyor technology, HVAC technology • Compliant with NFPA 79 standards • „TC-ER““ for use on machines and in open cable ducts • „WTTC“ Wind Turbine Tray Cable for use in wind turbines • „MTW“ Machine Tool Wire • „PLTC-ER“ Power Limited Tray Cable – Exposed Run • „ITC-ER“ Instrumentation Tray Cable – Exposed Run • In dry, moist and wet rooms Properties • Flexible wires with nylon for better resistance to pressure and impacts as per UL 1277 • Easy stripping and fast installation • Very flexible flexibility for complex installation distances and small bending radii • Improved oil resistance due to specifically developed PVC jacket • Sunlight-resistant • „Direct burial“ for installation in the ground • Silicone free • RoHS compliant Technical data Nominal voltage Test voltage Temperature range moving fixed Minimum bending radius moving fixed Burning behavior Oil resistant Approvals 1000 V WTTC 600 V TC, MTW 90 °C 300 V PLTC 3000 V -5 °C to +90 °C -40 °C to +90 °C D × 15 D×6 UL 1581, FT 4 Oil res II UL Type WTTC 1000 V UL Type TC-ER, MTW 600 V UL Type PLTC-ER, ITC-ER UL AWM 20866 CE RoHS Construction • Bare E-copper wire, ASTM, AWG Class K • Special PVC/nylon, THHN-THWN • Conductors black with white number print • Ground conductor green/yellow from 3 strands • Outer jacket Special PVC according to UL 1581 • Jacket color grey RAL 7001 Specifications are subject to change without prior notice. 10 Part No. Number of conductors/cross-section AWG 20 (10/30) A3082003 SI N TRAY-ER 3×AWG20 GR A3082004 SI N TRAY-ER 4×AWG20 GR A3082005 SI N TRAY-ER 5×AWG20 GR A3082007 SI N TRAY-ER 7×AWG20 GR A3082012 SI N TRAY-ER 12×AWG20 GR A3082018 SI N TRAY-ER 18×AWG20 GR A3082025 SI N TRAY-ER 25×AWG20 GR AWG 18 (19/30) A3081802 SI N TRAY-ER 2×AWG18 GR A3081803 SI N TRAY-ER 3×AWG18 GR A3081804 SI N TRAY-ER 4×AWG18 GR A3081805 SI N TRAY-ER 5×AWG18 GR A3081807 SI N TRAY-ER 7×AWG18 GR A3081809 SI N TRAY-ER 9×AWG18 GR A3081812 SI N TRAY-ER 12×AWG18 GR A3081818 SI N TRAY-ER 18×AWG18 GR A3081825 SI N TRAY-ER 25×AWG18 GR A3081834 SI N TRAY-ER 34×AWG18 GR A3081841 SI N TRAY-ER 41×AWG18 GR A3081850 SI N TRAY-ER 50×AWG18 GR AWG 16 (26/30) A3081602 SI N TRAY-ER 2×AWG16 GR A3081603 SI N TRAY-ER 3×AWG16 GR A3081604 SI N TRAY-ER 4×AWG16 GR A3081605 SI N TRAY-ER 5×AWG16 GR A3081607 SI N TRAY-ER 7×AWG16 GR A3081609 SI N TRAY-ER 9×AWG16 GR A3081612 SI N TRAY-ER 12×AWG16 GR A3081618 SI N TRAY-ER 18×AWG16 GR A3081625 SI N TRAY-ER 25×AWG16 GR A3081634 SI N TRAY-ER 34×AWG16 GR A3081641 SI N TRAY-ER 41×AWG16 GR AWG 14 (41/30) A3081403 SI N TRAY-ER 3×AWG14 GR A3081404 SI N TRAY-ER 4×AWG14 GR A3081405 SI N TRAY-ER 5×AWG14 GR A3081407 SI N TRAY-ER 7×AWG14 GR A3081409 SI N TRAY-ER 9×AWG14 GR A3081412 SI N TRAY-ER 12×AWG14 GR A3081418 SI N TRAY-ER 18×AWG14 GR A3081425 SI N TRAY-ER 25×AWG14 GR OD ∅ inches Weight Lbs/Mft Cu-Index Lbs/Mft 0.268 0.287 0.313 0.335 0.426 0.492 0.672 41.0 49.0 57.0 70.0 110.0 152.0 229.0 9 13 16 22 38 56 79 0.276 0.296 0.320 0.346 0.373 0.425 0.477 0.587 0.677 0.744 0.896 0.910 46.0 54.0 65.0 82.0 102.0 128.0 157.0 240.0 314.0 404.0 520.0 630.0 12 18 24 30 42 54 72 108 150 206 247 302 0.305 0.210 0.347 0.377 0.406 0.473 0.527 0.647 0.748 53.0 66.0 77.0 98.0 122.0 159.0 196.0 294.0 391.0 16 24 32 40 57 73 98 147 204 0.983 670.0 335 0.348 0.378 0.410 0.445 0.516 0.610 0.715 0.825 87.0 108.0 125.0 164.0 213.0 283.0 404.0 537.0 38 51 64 89 115 154 231 321 PVC control cables · unshielded LÜTZE SILFLEX® N PVC CONTROL TRAY CABLE With approvals for North America according to NEC, NFPA 79 and UL 508A Use of certifications / Einsatz der Zulassungen Code / Standard NEC NFPA 79 UL 508A Use / Einsatz Field level / Feldebene Machine level / Maschinenebene Cabinet level / Schaltschrankebene Application • Multi-conductor control cables with TC-ER „Exposed Run“ approval • Machine and device construction, transport and conveyor technology, HVAC technology • Compliant with NFPA 79 standards • „TC-ER““ for use on machines and in open cable ducts • „WTTC“ Wind Turbine Tray Cable for use in wind turbines • „MTW“ Machine Tool Wire • „PLTC-ER“ Power Limited Tray Cable – Exposed Run • „ITC-ER“ Instrumentation Tray Cable – Exposed Run • In dry, moist and wet rooms Properties • Flexible wires with nylon for better resistance to pressure and impacts as per UL 1277 • Easy stripping and fast installation • Very flexible flexibility for complex installation distances and small bending radii • Improved oil resistance due to specifically developed PVC jacket • Sunlight-resistant • „Direct burial“ for installation in the ground • Silicone free • RoHS compliant Technical data Nominal voltage Test voltage Temperature range moving fixed Minimum bending radius moving fixed Burning behavior Oil resistant Approvals Part No. Number of conductors/cross-section AWG 12 (65/30) A3081203 SI N TRAY-ER 3×AWG12 GR A3081204 SI N TRAY-ER 4×AWG12 GR A3081205 SI N TRAY-ER 5×AWG12 GR A3081207 SI N TRAY-ER 7×AWG12 GR AWG 10 (105/30) A3081004 SI N TRAY-ER 4×AWG10 GR A3081005 SI N TRAY-ER 5×AWG10 GR AWG 8 (168/30) A3080804 SI N TRAY-ER 4×AWG8 GR AWG 6 (266/30) A3080604 SI N TRAY-ER 4×AWG6 GR AWG 4 (413/30) A3080404 SI N TRAY-ER 4×AWG4 GR AWG 2 (665/30) A3080204 SI N TRAY-ER 4×AWG2 GR OD ∅ inches Weight Lbs/Mft Cu-Index Lbs/Mft 0.382 0.437 0.475 0.556 122.0 150.0 183.0 255.0 63 83 105 147 0.573 0.623 233.0 288.0 130 162 0.744 398.0 214 0.820 535.0 339 1.070 927.0 514 1.225 1352.0 874 1000 V WTTC 600 V TC, MTW 90 °C 300 V PLTC 3000 V -5 °C to +90 °C -40 °C to +90 °C D × 15 D×6 UL 1581, FT 4 Oil res II UL Type WTTC 1000 V UL Type TC-ER, MTW 600 V UL Type PLTC-ER, ITC-ER UL AWM 20866 CE RoHS Construction • Bare E-copper wire, ASTM, AWG Class K • Special PVC/nylon, THHN-THWN • Conductors black with white number print • Ground conductor green/yellow from 3 strands • Outer jacket Special PVC according to UL 1581 • Jacket color grey RAL 7001 Specifications are subject to change without prior notice. 11 PVC control cables · shielded LÜTZE SILFLEX® N (C) PVC CONTROL TRAY CABLE With approvals for North America according to NEC, NFPA 79 and UL 508A Use of certifications / Einsatz der Zulassungen Code / Standard NEC NFPA 79 UL 508A Use / Einsatz Field level / Feldebene Machine level / Maschinenebene Cabinet level / Schaltschrankebene Application • Multi-conductor control cables with TC-ER „Exposed Run“ approval • Machine and device construction, HVAC technology, heating and climate technology • Compliant with NFPA 79 standards • „TC-ER““ for use on machines and in open cable ducts • „WTTC“ Wind Turbine Tray Cable for use in wind turbines • „MTW“ Machine Tool Wire • „PLTC-ER“ Power Limited Tray Cable – Exposed Run • „ITC-ER“ Instrumentation Tray Cable • In dry, moist and wet rooms Properties • Flexible wires with nylon for better resistance to pressure and impacts as per UL 1277 • Easy stripping and fast installation • Very flexible flexibility for complex installation distances and small bending radii • Improved oil resistance due to specifically developed PVC jacket • Sunlight-resistant • „Direct burial“ for installation in the ground • Silicone free • RoHS compliant Technical data Nominal voltage Test voltage Temperature range moving fixed Minimum bending radius moving fixed Burning behavior Oil resistant Approvals 1000 V WTTC 600 V TC, MTW 90 °C 300 V PLTC 3000 V -5 °C to +90 °C -40 °C to +90 °C D × 15 D×6 UL 1581, FT 4 Oil res II UL Type WTTC 1000 V UL Type TC-ER, MTW 600 V UL Type PLTC-ER, ITC-ER UL AWM 20866 CE RoHS Construction • Bare E-copper wire, ASTM, AWG Class K • Special PVC/nylon, THHN-THWN • Foiled shield 100 % optical coverage • Drain wire, tin-plated copper • Braid from tinned copper wire, optical coverage ≥ 80 % • Conductors black with white number print • Ground conductor green/yellow from 3 strands • Outer jacket Special PVC according to UL 1581 • Jacket color grey RAL 7001 Specifications are subject to change without prior notice. 12 Part No. Number of conductors/cross-section AWG 20 (10/30) A3092003 SI N (C)PVC TRAY-ER (3×AWG20)GR A3092004 SI N (C)PVC TRAY-ER (4×AWG20)GR A3092005 SI N (C)PVC TRAY-ER (5×AWG20)GR A3092007 SI N (C)PVC TRAY-ER (7×AWG20)GR A3092012 SI N (C)PVC TRAY-ER (12×AWG20)GR A3092018 SI N (C)PVC TRAY-ER (18×AWG20)GR A3092025 SI N (C)PVC TRAY-ER (25×AWG20)GR AWG 18 (19/30) A3091802 SI N (C)PVC TRAY-ER (2×AWG18)GR A3091803 SI N (C)PVC TRAY-ER (3×AWG18)GR A3091804 SI N (C)PVC TRAY-ER (4×AWG18)GR A3091805 SI N (C)PVC TRAY-ER (5×AWG18)GR A3091807 SI N (C)PVC TRAY-ER (7×AWG18)GR A3091812 SI N (C)PVC TRAY-ER (12×AWG18)GR A3091818 SI N (C)PVC TRAY-ER (18×AWG18)GR A3091825 SI N (C)PVC TRAY-ER (25×AWG18)GR AWG 16 (26/30) A3091603 SI N (C)PVC TRAY-ER (3×AWG16)GR A3091604 SI N (C)PVC TRAY-ER (4×AWG16)GR A3091605 SI N (C)PVC TRAY-ER (5×AWG16)GR A3091607 SI N (C)PVC TRAY-ER (7×AWG16)GR A3091612 SI N (C)PVC TRAY-ER (12×AWG16)GR A3091618 SI N (C)PVC TRAY-ER (18×AWG16)GR A3091625 SI N (C)PVC TRAY-ER (25×AWG16)GR AWG 14 (41/30) A3091403 SI N (C)PVC TRAY-ER (3×AWG14)GR A3091404 SI N (C)PVC TRAY-ER (4×AWG14)GR A3091405 SI N (C)PVC TRAY-ER (5×AWG14)GR A3091407 SI N (C)PVC TRAY-ER (7×AWG14)GR A3091412 SI N (C)PVC TRAY-ER (12×AWG14)GR AWG 12 (65/30) A3091203 SI N (C)PVC TRAY-ER (3×AWG12)GR A3091204 SI N (C)PVC TRAY-ER (4×AWG12)GR AWG 10 (105/30) A3091004 SI N (C)PVC TRAY-ER (4×AWG10)GR OD ∅ inches Weight Lbs/Mft Cu-Index Lbs/Mft 0.295 0.315 0.336 0.360 0.450 0.520 0.620 56.0 65.0 74.0 92.0 131.0 181.0 246.0 20 25 28 36 56 78 102 0.305 0.320 0.345 0.368 0.395 0.500 0.610 0.692 61.0 71.0 86.0 100.0 121.0 180.0 268.0 342.0 23 30 36 44 58 91 131 177 0.343 0.370 0.398 0.430 0.575 0.665 0.770 87.0 102.0 119.0 145.0 239.0 327.0 423.0 39 48 58 75 121 174 233 0.375 0.406 0.440 0.475 0.640 110.0 133.0 154.0 198.0 316.0 57 72 85 113 182 0.425 0.460 150.0 182.0 89 110 0.594 284.0 169 PVC motor, servo and frequency converter cables shielded LÜTZE DRIVEFLEX XLPE (C) PVC With approvals for North America according to NEC, NFPA 79 and UL 508A Use of certifications / Einsatz der Zulassungen Code / Standard NEC NFPA 79 UL 508A Use / Einsatz Field level / Feldebene Machine level / Maschinenebene Cabinet level / Schaltschrankebene Application • Shielded motor connection cable, especially for connecting motors to frequency converters • Flexible design for easy installation • Compliant with NFPA 79 standards • Low capacitance and high dielectric strength for long cable lengths from inverter to motor • In dry and moist rooms • Especially for industrial environments in mechanical and system engineering • „TC-ER“ for use in machines and open cable ducts • Flexible Motor Supply (Flexible VFD & Servo) for connection to electrical drives • „WTTC“ Wind Turbine Tray Cable for use in wind turbines Part No. Number of strands/cross-section OD ∅ mm OD ∅ inches Weight Lbs/Mft Cu-Index Lbs/Mft A2161604 A2161404 A2161204 A2161004 A2160804 A2160604 A2160404 A2160204 (4GAWG16) (4GAWG14) (4GAWG12) (4GAWG10) (4GAWG8) (4GAWG6) (4GAWG4) (4GAWG2) 12.4 14.2 15.6 17.8 23.5 25.7 29.3 34.2 0.490 0.560 0.615 0.700 0.925 1.010 1.155 1.345 149.0 200.0 262.0 359.0 603.0 763.0 1126.0 1559.0 57 80 128 186 295 425 632 997 Properties • Special XLPE insulation with low capacitance • High dielectric strength • Effective EMC-compatible shielding thanks to 2-layer shield • PVC outer jacket, easy to strip • Sunlight-resistant • „Direct burial“ for installation in the ground • Silicone free • RoHS compliant Technical data Nominal voltage Test voltage Temperature range moving fixed Minimum bending radius moving fixed Burning behavior 1000 V Flexible VFD Servo Cable 1000 V WTTC 600 V TC-ER 4000 V -5 °C to +90 °C -40 °C to +90 °C D × 15 D×6 UL 1581, FT 4 Construction • E-copper wire tinned, ASTM, AWG Class K • Conductor insulation Spedial XLPE, RHW-2 moist/dry • Foiled shield 100 % optical coverage • Drain wire, tin-plated copper • Braid from tinned copper wire, optical coverage ≥ 80 % • Conductors black with white number print • Ground conductor green/yellow • Outer jacket Special PVC according to UL 1581 • Jacket color black RAL 9005 Specifications are subject to change without prior notice. 13 TPE Motor cables · shielded · static LÜTZE SILFLEX®M (C) TPE POWER TRAY CABLE With approvals for North America according to NEC, NFPA 79 and UL 508A Use of certifications / Einsatz der Zulassungen Code / Standard NEC NFPA 79 UL 508A Use / Einsatz Field level / Feldebene Machine level / Maschinenebene Cabinet level / Schaltschrankebene Application • Supply line for Allen-Bradley and other Systems • Shielded multi-conductor cable for motor and servo motor applications • Cable design for harsh industrial environments and operating conditions with high noise levels • Improved insulation design with additional conductor stress relief layer as a power distortion suppressant • Compliant with NFPA 79 standards tool wiring • TC-ER for use with cable trays without conduit, which can reduce material and labor costs • UL Type 1000V Flexible Motor Supply Cable for Motor/Power applications • Dry, damp and wet locations Properties • Conductor stress relief layer prevents premature cable failure and reduces corona effects, increasing reliability and lifetime • Flexible design with Nylon for crush impact resistance per UL 1277 and easy installation • Very round cable with small diameter • Specially formulated TPE jacket for superior oil resistance per Oil Res I and II • Resistant to many mineral and vegetable based cutting oils • Non-wicking fillers • Sunlight resistant • Direct burial • UL Type TC-Exposed Run • Talc free and Silicone free Technical data Nominal voltage Temperature range moving fixed Minimum bending radius moving fixed Approvals 1000 V Flexible Motor Supply 1000 V WTTC 600 V UL TC 600 V UL MTW 600 V UL AWM 105 °C -5 °C to +90 °C -40 °C to +90 °C (105 °C) D × 15 D×6 UL Flexible Motor Supply Cable UL Type WTTC 1000 V UL Type TC-ER MTW 600 V UL AWM Style 20328 CE RoHS REACH Class 1 Div. 2 per NEC Art. 336, 392, 501 C(UL) TC and CIC FT4 UL 1277 Oil Res I and II Construction • Bare E-copper wire, ASTM, AWG Class K • Conductor insulation PVC/Nylon insulation with conductor stress relief layer • Braid from tinned copper wire, optical coverage ≥85% • Strand color brown, black, bluePair: black, wihte • Ground conductor green/yellow • Outer jacket Special TPE according to UL 1581 • Jacket color orange RAL 2003 Allen-Bradley article designations are registered trademarks. Specifications are subject to change without prior notice. 14 Part No. No. of conductors incl. ground Construction without signal strands A3161604 AWG 16 (16/30) (4GAWG16) A3161404 AWG 14 (41/30) (4GAWG14) A3161204 AWG 12 (65/30) (4GAWG12) A3161004 AWG 10 (105/30) (4GAWG10) A3160804 AWG 8 (168/30) (4GAWG8) Assembly with 1 signal pair A3171604 AWG 16 (16/30) (4GAWG16+(2×AWG18)) A3171404 AWG 14 (41/30) (4GAWG14+(2×AWG18)) A3171204 AWG 12 (65/30) (4GAWG12+(2×AWG18)) A3171004 AWG 10 (105/30) (4GAWG10+(2×AWG18)) A3170804 AWG 8 (168/30) (4GAWG8+(2×AWG18)) A3170604 AWG 6 (266/30) (4GAWG6+(2×AWG18)) A3170404 AWG 4 (413/30) (4GAWG4+(2×AWG18)) A3170204 AWG 2 (665/30) (4GAWG2+(2×AWG18)) OD ∅ mm OD ∅ inches Weight Lbs/Mft Cu-Index Lbs/Mft 10.4 0.410 124.0 50 11.6 0.455 159.0 71 13.0 0.510 214.0 107 16.5 0.650 321.0 161 21.0 0.825 490.0 267 12.1 0.477 161.0 72 12.8 0.505 196.0 92 15.0 0.590 263.0 128 18.2 0.716 380.0 191 22.6 0.890 568.0 285 25.5 1.003 786.0 417 29.5 1.162 1119.0 613 34.0 1.340 1543.0 983 Copyright Protected trademarks and trade names are not always labelled as such in this publication. This does not mean they are free names as defined in the trademark and brand mark law. Publication does not imply that the descriptions or pictures used are free from rights of third parties. The information is published without regard to possible patent protection. Trade names are used without any guarantee that they can be used freely. In putting together text, pictures and data, we proceeded with the greatest care. Despite this, the possibility of errors cannot be completely excluded. We therefore reject any legal responsibility or liability. We are, of course, grateful for any recommendations for improvement or information useful for making corrections or establishing the truth. But the author does not assume any responsibility for the content of these documents. Cables Cable assemblies Cable fittings Cable conduits LSC wiring system Module- and Interface Technology Industrial Ethernet Suppression technology Industrial Power Supplies Intelligent current control Railway technology USA LUTZE INC. 13330 South Ridge Drive Charlotte, NC 28273 Tel.: +1 704 504-0222 Fax: +1 704 504-0223 info@lutze.com United Kingdom LÜTZE Ltd. Unit 3 Sandy Hill Park Sandy Way, Amington Tamworth, Staffs, B77 4DU Tel.: + 44 1827 31333-0 Fax: + 44 1827 31333-2 sales.gb@lutze.co.uk Austria LÜTZE Elektrotechnische Erzeugnisse Ges.m.b.H. office@luetze.at Switzerland LÜTZE AG info@luetze.ch France LUTZE SAS lutze@lutze.fr Spain LUTZE, S.L. info@lutze.es www.luetze.com www.lutze.com China Luetze Trading (Shanghai) Co.Ltd. info@luetze.cn 04.2016.P1UB06.USA1500 02.33 • © by Friedrich Lütze GmbH, Weinstadt, Deutschland • Printed in Germany. Subject to technical modification. Germany Friedrich Lütze GmbH Postfach 12 24 (PLZ 71366) Bruckwiesenstraße 17-19 D-71384 Weinstadt Tel.: +49 7151 6053-0 Fax: +49 7151 6053-277(-288) info@lutze.de