LANE COUNTY PUBLIC WORKS Minimum Code Standards for Residential Wiring i LAND MANAGEMENT DIVISION 3050 N DELTA HYW, EUGENE OR 97408 This guide has been created to help the homeowner with their own home electrical projects. Criteria for homeowners performing electrical work on their own home: The home shall not be for sale, rent, lease or exchange for at least one year after all final inspections. Only an owner and their immediate family (spouse, brother sister, son, daughter, mother or father) may help with these projects. No other person other than those listed my engage in this work. The person who has done the work must be on site to answer questions during inspections. Lighting & other receptacles Kitchen counter & dining rm. receptacles Built in microwave Dishwasher Kitchen disposer Range Washer & receptacles in utility rm. only! Dryer Bathroom receptacles only Wall heaters (230 volt) Water heaters Heating, ventilating, air conditioning units. Any other appliance Minimum for every 500 sq.ft/circuit - 15 amp, 14 AWG Minimum two 20 amp, 12 AWG circuits One 20 amp, 12 AWG One 15 or 20 amp, 12 or 14 AWG One 15 or 20 amp, 12 or 14 AWG One 40 amp, #8-4 copper or #6-4 aluminum One 20 amp, 12 AWG One 30 amp, 10-3 with ground One 20 amp, 12 AWG Under: 3600 watts - 12 AWG / 5500watts - 10 AWG One 30 amp, 10AWG Wire & circuit size as listed on the unit . One 120 volt GFI receptacle within 25 ft. on same floor and not thru door or window. Wire and circuit size as listed on unit. NOL NOL NOL NOL NOL NOL NOL NOL NOL NOL NOL NOL NOL NOL - no other loads. (Nothing else shall be on the circuit). RECEPTACLES – Plug Outlets AWG – American Wire Gauge GFI – Ground Fault Interrupter Here are some general requirements: All 120 volt outlets, switches, etc. in bedrooms shall be arc fault protected at the panel. Smoke detectors shall be in each bedroom and outside bedroom area, as well on every level of house and tied together with three-wire with ground. Before calling for covering inspection, all wires shall be stripped and grounding conductors made up with pig tails. Do not cut wire shorter than 6” from the front of the box. Bond all metal boxes with approved means. Do not install devices on cover inspection except one or two GFI that will be used for power while under construction. Staple wire flat (not edge) every 4 feet. Staple within 12 inches or closer of each box on same stud as box. Be sure all connections are secure and tight. LANE CO. MCSFRW REV 07-01-14 DSL LAND MANAGEMENT DIVISION / PUBLIC WORKS DEPARTMENT / 3050 N DELTA HYW / EUGENE, OR 97408 / FAX 541/682-3947 BUILDING (541) 682-4651 / PLANNING (541) 682-3577 / SURVEYORS (541) 682-4195 / COMPLIANCE (541) 682-3724 / ON-SITE SEWAGE (541) 682-3754