Technical Information - Efficiency and Derating SUNNY BOY

advertisement
Technical Information
Efficiency and Derating
SUNNY BOY US/SUNNY TRIPOWER US
WKG-Derating-US-TI-en-15 | Version 1.5
ENGLISH
Legal Provisions
SMA Solar Technology America LLC
Legal Provisions
Copyright © 2016 SMA Solar Technology America LLC. All rights reserved.
No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any
form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without
the prior written permission of SMA Solar Technology America LLC.
Neither SMA Solar Technology America LLC nor SMA Solar Technology Canada Inc. makes
representations, express or implied, with respect to this documentation or any of the equipment
and/or software it may describe, including (with no limitation) any implied warranties of utility,
merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed.
Neither SMA Solar Technology America LLC nor its distributors or dealers nor SMA Solar
Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or
consequential damages under any circumstances.
(The exclusion of implied warranties may not apply in all cases under some statutes, and thus the
above exclusion may not apply.)
Specifications are subject to change without notice. Every attempt has been made to make this
document complete, accurate and up-to-date. Readers are cautioned, however, that product
improvements and field usage experience may cause SMA Solar Technology America LLC and/or
SMA Solar Technology Canada Inc. to make changes to these specifications without advance
notice, or per contract provisions in those cases where a supply agreement requires advance
notice. SMA shall not be responsible for any damages, including indirect, incidental or
consequential damages, caused by reliance on the material presented, including, but not limited to,
omissions, typographical errors, arithmetical errors or listing errors in the content material.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not
mean that a product or brand is not a registered trademark.
The BLUETOOTH® word mark and logos are registered trademarks of Bluetooth SIG, Inc. and any
use of such marks by SMA America LLC and SMA Solar Technology Canada Inc. is under license.
Modbus® is a registered trademark of Schneider Electric and is licensed by the
Modbus Organization, Inc.
QR Code is a registered trademark of DENSO WAVE INCORPORATED.
Phillips® and Pozidriv® are registered trademarks of Phillips Screw Company.
Torx® is a registered trademark of Acument Global Technologies, Inc.
SMA Solar Technology America LLC
6020 West Oaks Blvd.
Suite 300 Rocklin, CA 95765 U.S.A.
SMA Solar Technology Canada Inc.
2425 Matheson Blvd. E
7th Floor
Mississauga, ON L4W 5K4
Canada
2
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
General Warnings
General Warnings
All electrical installations must be carried out in accordance with the local electrical standards
and the National Electrical Code® ANSI/NFPA 70 or the Canadian Electrical Code® CSA
C22.1. This document does not replace and is not intended to replace any local, state,
provincial, federal or national laws, regulations or codes applicable to the installation and use of
the product, including without limitation applicable electrical safety codes. All installations must
conform with the laws, regulations, codes and standards applicable in the jurisdiction of
installation. SMA assumes no responsibility for the compliance or non-compliance with such laws
or codes in connection with the installation of the product.
The product contains no user-serviceable parts.
Before installing or using the product, read all of the instructions, cautions, and warnings in this
manual.
Before connecting the product to the electrical utility grid, contact the local utility company. This
connection must be made only by qualified personnel.
Wiring of the product must be made by qualified personnel only.
Technical Information
WKG-Derating-US-TI-en-15
3
Table of Contents
SMA Solar Technology America LLC
Table of Contents
1
Information on this Document .................................................
1.1
1.2
9
Validity ................................................................................................ 9
Target group....................................................................................... 9
2
Data Explanation...................................................................... 10
3
Sunny Boy with transformer .................................................... 11
3.1
SB 2000HFUS-30.............................................................................. 11
3.1.1
3.1.2
3.1.3
3.1.4
3.2
17
18
19
19
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
20
21
22
22
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
23
24
25
25
SB 3800-US-10.................................................................................. 26
3.6.1
4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
SB 3000US-12 .................................................................................. 23
3.5.1
3.5.2
3.5.3
3.5.4
3.6
14
15
16
16
SB 3000US ........................................................................................ 20
3.4.1
3.4.2
3.4.3
3.4.4
3.5
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
SB 3000HFUS-30.............................................................................. 17
3.3.1
3.3.2
3.3.3
3.3.4
3.4
11
12
13
13
SB 2500HFUS-30.............................................................................. 14
3.2.1
3.2.2
3.2.3
3.2.4
3.3
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
Efficiency at 208 V AC.................................................................. 26
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
3.6.2
3.6.3
3.6.4
3.7
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
29
30
31
31
SB 4000US ........................................................................................ 32
3.8.1
3.8.2
3.8.3
3.8.4
3.9
Efficiency at 240 V AC.................................................................. 27
Derating behavior at 208 V AC ................................................... 28
Derating behavior at 240 V AC ................................................... 28
SB 3800US-12 .................................................................................. 29
3.7.1
3.7.2
3.7.3
3.7.4
3.8
Table of Contents
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
32
33
34
34
SB 4000US-12 .................................................................................. 35
3.9.1
3.9.2
3.9.3
3.9.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
35
36
37
37
3.10 SB 5000US/SB 5000US-12 ............................................................ 38
3.10.1
3.10.2
3.10.3
3.10.4
3.10.5
3.10.6
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Efficiency at 277 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
Derating behavior at 277 V AC ...................................................
38
39
40
41
41
42
3.11 SB 6000US/SB 6000US-12 ............................................................ 43
3.11.1
3.11.2
3.11.3
3.11.4
3.11.5
3.11.6
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Efficiency at 277 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
Derating behavior at 277 V AC ...................................................
43
44
45
46
46
47
3.12 SB 7000US/SB 7000US-12 ............................................................ 48
3.12.1 Efficiency at 208 V AC.................................................................. 48
3.12.2 Efficiency at 240 V AC.................................................................. 49
Technical Information
WKG-Derating-US-TI-en-15
5
Table of Contents
3.12.3
3.12.4
3.12.5
3.12.6
SMA Solar Technology America LLC
Efficiency at 277 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
Derating behavior at 277 V AC ...................................................
50
51
51
52
3.13 SB 8000US/SB 8000US-12 ............................................................ 53
3.13.1
3.13.2
3.13.3
3.13.4
4
53
54
55
55
Sunny Boy without transformer .............................................. 56
4.1
SB 3000TL-US-22 .............................................................................. 56
4.1.1
4.1.2
4.1.3
4.1.4
4.2
4.3
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior without fan ......................................................
Derating behavior with fan............................................................
60
61
62
63
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior without fan ......................................................
Derating behavior with fan............................................................
64
65
66
67
SB 5000TL-US-22 .............................................................................. 68
4.4.1
4.4.2
4.4.3
4.4.4
4.5
56
57
58
59
SB 4000TL-US-22 .............................................................................. 64
4.3.1
4.3.2
4.3.3
4.3.4
4.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior without fan ......................................................
Derating behavior with fan............................................................
SB 3800TL-US-22 .............................................................................. 60
4.2.1
4.2.2
4.2.3
4.2.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior without fan ......................................................
Derating behavior with fan............................................................
68
69
70
71
SB 6000TLUS-12 ............................................................................... 72
4.5.1
4.5.2
4.5.3
4.5.4
6
Efficiency at 240 V AC..................................................................
Efficiency at 277 V AC..................................................................
Derating behavior at 240 V AC ...................................................
Derating behavior at 277 V AC ...................................................
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
WKG-Derating-US-TI-en-15
72
73
74
74
Technical Information
SMA Solar Technology America LLC
4.6
SB 6000TL-US-22 .............................................................................. 75
4.6.1
4.6.2
4.6.3
4.7
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
78
79
80
80
SB 7000TL-US-22 .............................................................................. 81
4.8.1
4.8.2
4.8.3
4.9
Efficiency at 208 V AC.................................................................. 75
Efficiency at 240 V AC.................................................................. 76
Derating behavior with fan............................................................ 77
SB 7000TLUS-12 ............................................................................... 78
4.7.1
4.7.2
4.7.3
4.7.4
4.8
Table of Contents
Efficiency at 208 V AC.................................................................. 81
Efficiency at 240 V AC.................................................................. 82
Derating behavior with fan............................................................ 83
SB 7700TL-US-22 .............................................................................. 84
4.9.1
4.9.2
4.9.3
Efficiency at 208 V AC.................................................................. 84
Efficiency at 240 V AC.................................................................. 85
Derating behavior with fan............................................................ 86
4.10 SB 8000TLUS-12 ............................................................................... 87
4.10.1
4.10.2
4.10.3
4.10.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
87
88
89
89
4.11 SB 9000TLUS-12 ............................................................................... 90
4.11.1
4.11.2
4.11.3
4.11.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
90
91
92
92
4.12 SB 10000TLUS-12............................................................................. 93
4.12.1
4.12.2
4.12.3
4.12.4
Efficiency at 208 V AC..................................................................
Efficiency at 240 V AC..................................................................
Derating behavior at 208 V AC ...................................................
Derating behavior at 240 V AC ...................................................
93
94
95
95
4.13 SB 11000TLUS-12............................................................................. 96
4.13.1 Efficiency at 240 V AC.................................................................. 96
4.13.2 Derating behavior at 240 V AC ................................................... 97
Technical Information
WKG-Derating-US-TI-en-15
7
Table of Contents
5
Sunny Tripower......................................................................... 98
5.1
STP 12000TL-US-10 .......................................................................... 98
5.1.1
5.1.2
5.2
5.3
Efficiency at 277 V AC..................................................................102
Derating behavior at 277 V AC ...................................................103
STP 24000TL-US-10 ..........................................................................104
5.4.1
5.4.2
5.5
Efficiency at 277 V AC..................................................................100
Derating behavior at 277 V AC ...................................................101
STP 20000TL-US-10 ..........................................................................102
5.3.1
5.3.2
5.4
Efficiency at 277 V AC.................................................................. 98
Derating behavior at 277 V AC ................................................... 99
STP 15000TL-US-10 ..........................................................................100
5.2.1
5.2.2
Efficiency at 277 V AC..................................................................104
Derating behavior at 277 V AC ...................................................105
STP 30000TL-US-10 ..........................................................................106
5.5.1
5.5.2
8
SMA Solar Technology America LLC
Efficiency at 277 V AC..................................................................106
Derating behavior at 277 V AC ...................................................107
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
1
1.1
1 Information on this Document
Information on this Document
Validity
This document describes in graphic and tabular form the efficiency profile and the derating
behavior of the following SMA inverters (status: 02/2016, subject to technical changes):
Sunny Boy with transformer Sunny Boy without transformer
Sunny Tripower
SB 2000HFUS-30
SB 3000TL-US-22
STP 12000TL-US-10
SB 2500HFUS-30
SB 3800TL-US-22
STP 15000TL-US-10
SB 3000HFUS-30
SB 4000TL-US-22
STP 20000TL-US-10
SB 3000US
SB 5000TL-US-22
STP 24000TL-US-10
SB 3000-US-12
SB 6000TLUS-12
STP 30000TL-US-10
SB 3800-US-10
SB 6000TL-US-22
SB 3800-US-12
SB 7000TLUS-12
SB 4000US
SB 7000TL-US-22
SB 4000US-12
SB 7700TL-US-22
SB 5000US
SB 8000TLUS-12
SB 5000US-12
SB 9000TLUS-12
SB 6000US
SB 10000TLUS-12
SB 6000US-12
SB 11000TLUS-12
SB 7000US
SB 7000US-12
SB 8000US
SB 8000US-12
1.2
Target group
The information in this document is intended for installers and operators of PV systems with
SMA inverters as well as for PV system planners.
Technical Information
WKG-Derating-US-TI-en-15
9
2 Data Explanation
2
SMA Solar Technology America LLC
Data Explanation
Efficiency Profile - Curve and Measured Values
The efficiency is the ratio of output power to input power and is given as a percentage value. This
document describes the inverter efficiency in graphic and tabular form. The efficiency is given for
the minimum MPP voltage, the rated input voltage and the maximum MPP voltage.
Maximum efficiency and Californian efficiency
The maximum efficiency is the highest inverter efficiency at rated input voltage. The Californian
efficiency is calculated by weighing different partial load efficiencies and the full load efficiency at
the rated input voltage according to the frequency in which they occur.
The calculation formula is: ηCEC = (0.04 x η10%) + (0.05 x η20%) + (0.12 x η30%) + (0.21 x η50%) +
(0.53 x η75%) + (0.05 x η100%)
Derating Behavior
Safety mechanisms are implemented in the inverter protecting the inverter against damage due to
too high ambient temperatures or too high output currents. This behavior reduces the inverter output
power ("derating"). In this document, the derating behavior of the inverters is shown in graphic
form. The derating behavior is given for the minimum MPP voltage, the rated input voltage and the
maximum MPP voltage.
10
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3
Sunny Boy with transformer
3.1
3.1.1
SB 2000HFUS-30
Efficiency at 208 V AC
Maximum efficiency, ηmax
98.1 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
92.2 %
95.1 %
96.4 %
20 %
95.2 %
96.8 %
97.8 %
30 %
96.0 %
97.4 %
98.1 %
50 %
96.3 %
97.4 %
98.0 %
75 %
95.9 %
97.2 %
97.6 %
100 %
95.2 %
96.6 %
97.1 %
Technical Information
WKG-Derating-US-TI-en-15
11
3 Sunny Boy with transformer
3.1.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
98.1 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
92.6 %
93.9 %
95.8 %
20 %
95.2 %
97.0 %
97.6 %
30 %
96.2 %
97.3 %
98.0 %
50 %
96.6 %
97.6 %
98.1 %
75 %
96.4 %
97.6 %
97.9 %
100 %
95.9 %
97.2 %
97.6 %
12
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.1.3
Derating behavior at 208 V AC
SB 2000HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
30/86
20/68
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.1.4
Derating behavior at 240 V AC
SB 2000HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
13
3 Sunny Boy with transformer
3.2
3.2.1
SMA Solar Technology America LLC
SB 2500HFUS-30
Efficiency at 208 V AC
Maximum efficiency, ηmax
97.4 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
415 V
Maximum MPP
voltage
480 V
10 %
94.3 %
95.6 %
95.0 %
20 %
95.7 %
96.8 %
96.8 %
30 %
96.4 %
97.2 %
97.3 %
50 %
96.4 %
97.2 %
97.4 %
75 %
96.0 %
96.9 %
97.1 %
100 %
95.1 %
96.3 %
96.5 %
14
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.2.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.2 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
415 V
Maximum MPP
voltage
480 V
10 %
93.4 %
93.6 %
93.6 %
20 %
95.3 %
96.0 %
96.1 %
30 %
96.1 %
96.7 %
96.9 %
50 %
96.1 %
97.1 %
97.2 %
75 %
96.2 %
97.0 %
97.1 %
100 %
95.5 %
96.6 %
96.7 %
Technical Information
WKG-Derating-US-TI-en-15
15
3 Sunny Boy with transformer
3.2.3
SMA Solar Technology America LLC
Derating behavior at 208 V AC
SB 2500HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.2.4
Derating behavior at 240 V AC
SB 2500HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
16
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.3
3.3.1
SB 3000HFUS-30
Efficiency at 208 V AC
Maximum efficiency, ηmax
97.5 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
415 V
Maximum MPP
voltage
480 V
10 %
94.2 %
95.4 %
96.2 %
20 %
96.0 %
96.7 %
97.4 %
30 %
96.4 %
96.8 %
97.6 %
50 %
96.2 %
96.8 %
97.4 %
75 %
95.5 %
96.3 %
96.8 %
100 %
94.2 %
95.5 %
96.0 %
Technical Information
WKG-Derating-US-TI-en-15
17
3 Sunny Boy with transformer
3.3.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.4 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
415 V
Maximum MPP
voltage
480 V
10 %
93.8 %
94.4 %
95.7 %
20 %
95.9 %
96.3 %
97.1 %
30 %
96.4 %
96.7 %
97.4 %
50 %
96.4 %
96.9 %
97.4 %
75 %
95.9 %
96.7 %
97.1 %
100 %
94.9 %
96.1 %
96.5 %
18
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.3.3
Derating behavior at 208 V AC
SB 3000HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
30/86
20/68
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.3.4
Derating behavior at 240 V AC
SB 3000HFUS-30
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 200 V DC
0.2
VPV = 410 V DC
VPV = 480 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
19
3 Sunny Boy with transformer
3.4
3.4.1
SMA Solar Technology America LLC
SB 3000US
Efficiency at 208 V AC
Maximum efficiency, ηmax
95.7 %
Californian efficiency, ηCEC
95.3 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
250 V
Maximum MPP
voltage
400 V
10 %
93.8 %
94.4 %
95.7 %
20 %
95.9 %
96.3 %
97.1 %
30 %
96.4 %
96.7 %
97.4 %
50 %
96.4 %
96.9 %
94.7 %
75 %
95.9 %
96.7 %
94.2 %
100 %
94.9 %
96.1 %
93.5 %
20
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.4.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.5 %
Californian efficiency, ηCEC
96.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
220 V
Rated input voltage
250 V
Maximum MPP
voltage
400 V
10 %
93.4 %
92.5 %
90.5 %
20 %
95.9 %
95.8 %
94.6 %
30 %
96.3 %
96.0 %
95.4 %
50 %
96.5 %
96.1 %
95.3 %
75 %
96.1 %
95.8 %
95.2 %
100 %
95.6 %
95.1 %
94.6 %
Technical Information
WKG-Derating-US-TI-en-15
21
3 Sunny Boy with transformer
3.4.3
Derating behavior at 208 V AC
3.4.4
Derating behavior at 240 V AC
22
WKG-Derating-US-TI-en-15
SMA Solar Technology America LLC
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.5
3.5.1
SB 3000US-12
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.1 %
Californian efficiency, ηCEC
95.3 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
200 V
Rated input voltage
250 V
Maximum MPP
voltage
400 V
10 %
94.0 %
93.1 %
91.6 %
20 %
95.8 %
95.9 %
94.8 %
30 %
96.0 %
95.7 %
95.2 %
50 %
95.8 %
95.6 %
94.7 %
75 %
95.1 %
94.9 %
94.2 %
100 %
94.3 %
94.0 %
93.5 %
Technical Information
WKG-Derating-US-TI-en-15
23
3 Sunny Boy with transformer
3.5.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.5 %
Californian efficiency, ηCEC
96.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
200 V
Rated input voltage
250 V
Maximum MPP
voltage
400 V
10 %
93.4 %
92.5 %
90.5 %
20 %
95.9 %
95.8 %
94.6 %
30 %
96.3 %
96.0 %
95.4 %
50 %
96.5 %
96.1 %
95.3 %
75 %
96.1 %
95.8 %
95.2 %
100 %
95.6 %
95.1 %
94.6 %
24
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
3.5.3
Derating behavior at 208 V AC
3.5.4
Derating behavior at 240 V AC
Technical Information
3 Sunny Boy with transformer
WKG-Derating-US-TI-en-15
25
3 Sunny Boy with transformer
3.6
3.6.1
SMA Solar Technology America LLC
SB 3800-US-10
Efficiency at 208 V AC
Maximum efficiency, ηmax
97.1 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.6 %
93.5 %
91.6 %
20 %
96.3 %
95.5 %
94.4 %
30 %
96.7 %
96.1 %
95.3 %
50 %
96.8 %
96.8 %
95.6 %
75 %
96.4 %
96.4 %
95.6 %
100 %
95.8 %
95.8 %
95.1 %
26
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.6.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.6 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.6 %
93.5 %
91.6 %
20 %
96.3 %
95.5 %
94.4 %
30 %
96.7 %
96.1 %
95.3 %
50 %
96.8 %
96.3 %
95.6 %
75 %
96.4 %
96.0 %
95.6 %
100 %
95.8 %
95.5 %
95.1 %
Technical Information
WKG-Derating-US-TI-en-15
27
3 Sunny Boy with transformer
3.6.3
Derating behavior at 208 V AC
3.6.4
Derating behavior at 240 V AC
28
WKG-Derating-US-TI-en-15
SMA Solar Technology America LLC
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.7
3.7.1
SB 3800US-12
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.6 %
93.5 %
91.6 %
20 %
96.3 %
95.5 %
94.4 %
30 %
96.7 %
96.1 %
95.3 %
50 %
96.8 %
96.3 %
95.6 %
75 %
96.4 %
96.0 %
95.6 %
100 %
95.8 %
95.5 %
95.1 %
Technical Information
WKG-Derating-US-TI-en-15
29
3 Sunny Boy with transformer
3.7.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.7 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.6 %
93.5 %
91.6 %
20 %
96.3 %
95.5 %
94.4 %
30 %
96.7 %
96.1 %
95.3 %
50 %
96.8 %
96.3 %
95.6 %
75 %
96.4 %
96.0 %
95.6 %
100 %
95.8 %
95.5 %
95.1 %
30
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
3.7.3
Derating behavior at 208 V AC
3.7.4
Derating behavior at 240 V AC
Technical Information
3 Sunny Boy with transformer
WKG-Derating-US-TI-en-15
31
3 Sunny Boy with transformer
3.8
3.8.1
SMA Solar Technology America LLC
SB 4000US
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.7 %
Californian efficiency, ηCEC
95.9 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.3 %
93.5 %
91.5 %
20 %
96.3 %
96.2 %
94.9 %
30 %
96.5 %
96.1 %
95.4 %
50 %
96.4 %
96.1 %
95.1 %
75 %
95.8 %
95.5 %
94.8 %
100 %
94.9 %
94.8 %
94.0 %
32
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.8.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.7 %
Californian efficiency, ηCEC
96.3 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
92.5 %
91.9 %
89.1 %
20 %
96.4 %
96.2 %
94.7 %
30 %
96.8 %
96.3 %
95.6 %
50 %
96.7 %
96.5 %
95.5 %
75 %
96.4 %
96.0 %
96.0 %
100 %
96.0 %
95.5 %
95.5 %
Technical Information
WKG-Derating-US-TI-en-15
33
3 Sunny Boy with transformer
3.8.3
Derating behavior at 208 V AC
3.8.4
Derating behavior at 240 V AC
34
WKG-Derating-US-TI-en-15
SMA Solar Technology America LLC
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.9
3.9.1
SB 4000US-12
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.7 %
Californian efficiency, ηCEC
95.9 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.3 %
93.5 %
91.5 %
20 %
96.3 %
96.2 %
94.9 %
30 %
96.5 %
96.1 %
95.4 %
50 %
96.4 %
96.1 %
95.1 %
75 %
95.8 %
95.5 %
94.8 %
100 %
94.9 %
94.8 %
94.0 %
Technical Information
WKG-Derating-US-TI-en-15
35
3 Sunny Boy with transformer
3.9.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.7 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.6 %
93.5 %
91.6 %
20 %
96.3 %
95.5 %
94.4 %
30 %
96.7 %
96.1 %
95.3 %
50 %
96.8 %
96.3 %
95.6 %
75 %
96.4 %
96.0 %
95.6 %
100 %
95.8 %
95.5 %
95.1 %
36
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
3.9.3
Derating behavior at 208 V AC
3.9.4
Derating behavior at 240 V AC
Technical Information
3 Sunny Boy with transformer
WKG-Derating-US-TI-en-15
37
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.10 SB 5000US/SB 5000US-12
3.10.1 Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
91.5 %
89.9 %
86.3 %
20 %
95.7 %
95.0 %
92.5 %
30 %
96.2 %
95.7 %
94.3 %
50 %
96.7 %
96.2 %
95.0 %
75 %
96.7 %
96.4 %
95.1 %
100 %
96.3 %
96.0 %
95.0 %
38
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.10.2 Efficiency at 240 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
91.0 %
89.7 %
86.2 %
20 %
95.7 %
94.9 %
92.5 %
30 %
96.2 %
95.7 %
94.3 %
50 %
96.8 %
96.2 %
95.2 %
75 %
96.8 %
96.2 %
95.2 %
100 %
96.5 %
96.2 %
95.1 %
Technical Information
WKG-Derating-US-TI-en-15
39
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.10.3 Efficiency at 277 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.3 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
91.5 %
90.0 %
86.3 %
20 %
95.8 %
95.0 %
92.3 %
30 %
96.5 %
95.8 %
94.4 %
50 %
96.8 %
96.2 %
95.2 %
75 %
96.5 %
96.5 %
95.2 %
100 %
96.6 %
96.2 %
95.2 %
40
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.10.4 Derating behavior at 208 V AC
SB 5000US / SB 5000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.10.5 Derating behavior at 240 V AC
SB 5000US / SB 5000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
41
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.10.6 Derating behavior at 277 V AC
SB 5000US / SB 5000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
42
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.11 SB 6000US/SB 6000US-12
3.11.1 Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.4 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
92.5 %
91.2 %
88.0 %
20 %
95.8 %
95.6 %
93.5 %
30 %
96.5 %
95.9 %
94.8 %
50 %
96.9 %
96.3 %
94.6 %
75 %
96.5 %
96.1 %
94.9 %
100 %
95.9 %
95.6 %
94.6 %
Technical Information
WKG-Derating-US-TI-en-15
43
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.11.2 Efficiency at 240 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
92.6 %
91.3 %
87.9 %
20 %
96.1 %
95.6 %
93.6 %
30 %
96.5 %
96.0 %
94.8 %
50 %
96.8 %
96.3 %
95.1 %
75 %
96.7 %
96.3 %
95.0 %
100 %
96.0 %
95.9 %
94.8 %
44
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.11.3 Efficiency at 277 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
92.3 %
91.3 %
87.8 %
20 %
96.0 %
95.6 %
93.6 %
30 %
96.7 %
96.2 %
94.9 %
50 %
97.0 %
96.4 %
95.2 %
75 %
96.7 %
96.4 %
95.1 %
100 %
96.5 %
96.0 %
94.9 %
Technical Information
WKG-Derating-US-TI-en-15
45
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.11.4 Derating behavior at 208 V AC
SB 6000US / SB 6000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.11.5 Derating behavior at 240 V AC
SB 6000US / SB 6000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
46
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.11.6 Derating behavior at 277 V AC
SB 6000US / SB 6000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
47
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.12 SB 7000US/SB 7000US-12
3.12.1 Efficiency at 208 V AC
Maximum efficiency, ηmax
97.0 %
Californian efficiency, ηCEC
96.3 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
94.0 %
92.7 %
89.7 %
20 %
96.3 %
96.1 %
94.2 %
30 %
97.1 %
96.1 %
95.0 %
50 %
96.7 %
96.2 %
94.9 %
75 %
96.2 %
95.9 %
94.8 %
100 %
95.4 %
95.3 %
94.1 %
48
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.12.2 Efficiency at 240 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
93.7 %
92.3 %
89.3 %
20 %
96.2 %
96.1 %
94.3 %
30 %
96.8 %
96.1 %
95.1 %
50 %
96.9 %
96.4 %
95.6 %
75 %
96.5 %
96.1 %
95.0 %
100 %
95.8 %
95.6 %
94.7 %
Technical Information
WKG-Derating-US-TI-en-15
49
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.12.3 Efficiency at 277 V AC
Maximum efficiency, ηmax
96.9 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
250 V
Rated input voltage
310 V
Maximum MPP
voltage
480 V
10 %
93.7 %
92.5 %
89.3 %
20 %
96.3 %
96.1 %
94.2 %
30 %
96.8 %
96.3 %
95.2 %
50 %
97.0 %
96.5 %
95.0 %
75 %
96.5 %
96.2 %
95.1 %
100 %
95.9 %
95.6 %
94.6 %
50
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.12.4 Derating behavior at 208 V AC
SB 7000US / SB 7000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.12.5 Derating behavior at 240 V AC
SB 7000US / SB 7000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
51
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.12.6 Derating behavior at 277 V AC
SB 7000US / SB 7000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 360 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
52
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.13 SB 8000US/SB 8000US-12
3.13.1 Efficiency at 240 V AC
Maximum efficiency, ηmax
97.1 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
95.0 %
94.6 %
93.1 %
20 %
96.5 %
96.2 %
95.3 %
30 %
96.8 %
96.6 %
95.8 %
50 %
96.8 %
96.6 %
96.0 %
75 %
96.5 %
96.3 %
95.7 %
100 %
96.0 %
96.3 %
95.9 %
Technical Information
WKG-Derating-US-TI-en-15
53
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.13.2 Efficiency at 277 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.2 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
95.1 %
94.9 %
93.5 %
20 %
96.2 %
95.9 %
95.0 %
30 %
96.5 %
96.3 %
95.4 %
50 %
96.5 %
96.2 %
95.5 %
75 %
96.2 %
95.9 %
95.2 %
100 %
95.6 %
95.3 %
94.7 %
54
WKG-Derating-US-TI-en-15
Technical Information
3 Sunny Boy with transformer
SMA Solar Technology America LLC
3.13.3 Derating behavior at 240 V AC
SB 8000US / SB 8000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 440 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
3.13.4 Derating behavior at 277 V AC
SB 8000US / SB 8000US-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 440 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
55
4 Sunny Boy without transformer
4
SMA Solar Technology America LLC
Sunny Boy without transformer
4.1
4.1.1
SB 3000TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
92.8 %
93.5 %
92.7 %
20 %
94.9 %
95.6 %
95.3 %
30 %
95.5 %
96.3 %
96.1 %
50 %
95.9 %
96.8 %
96.6 %
75 %
95.8 %
96.8 %
96.6 %
100 %
95.5 %
96.6 %
96.4 %
56
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.1.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.1 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
91.5 %
94.3 %
91.1 %
20 %
94.7 %
95.9 %
95.3 %
30 %
95.7 %
96.5 %
96.4 %
50 %
96.2 %
97.0 %
97.0 %
75 %
96.0 %
97.1 %
97.1 %
100 %
95.6 %
97.1 %
96.8 %
Technical Information
WKG-Derating-US-TI-en-15
57
4 Sunny Boy without transformer
4.1.3
SMA Solar Technology America LLC
Derating behavior without fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
58
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.1.4
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
59
4 Sunny Boy without transformer
4.2
4.2.1
SMA Solar Technology America LLC
SB 3800TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
97.2 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
93.7 %
93.7 %
93.6 %
20 %
95.6 %
96.1 %
96.0 %
30 %
96.0 %
97.0 %
96.6 %
50 %
96.1 %
97.1 %
97.0 %
75 %
95.9 %
97.0 %
97.0 %
100 %
95.6 %
96.9 %
96.9 %
60
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.2.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.5 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
93.2 %
95.3 %
93.0 %
20 %
95.5 %
96.9 %
96.3 %
30 %
96.0 %
97.3 %
96.9 %
50 %
96.2 %
97.4 %
97.3 %
75 %
96.0 %
97.5 %
97.3 %
100 %
95.6 %
97.3 %
97.3 %
Technical Information
WKG-Derating-US-TI-en-15
61
4 Sunny Boy without transformer
4.2.3
SMA Solar Technology America LLC
Derating behavior without fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
62
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.2.4
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
63
4 Sunny Boy without transformer
4.3
4.3.1
SMA Solar Technology America LLC
SB 4000TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.6 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
93.9 %
94.7 %
93.9 %
20 %
95.4 %
96.2 %
95.4 %
30 %
95.8 %
96.6 %
95.8 %
50 %
95.8 %
96.8 %
95.8 %
75 %
95.5 %
96.6 %
95.5 %
100 %
95.0 %
96.4 %
95.0 %
64
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.3.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.2 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.0 %
94.8 %
94.6 %
20 %
95.5 %
96.4 %
96.3 %
30 %
95.9 %
96.9 %
96.8 %
50 %
96.0 %
97.2 %
97.0 %
75 %
95.7 %
97.1 %
97.0 %
100 %
95.3 %
96.9 %
96.8 %
Technical Information
WKG-Derating-US-TI-en-15
65
4 Sunny Boy without transformer
4.3.3
SMA Solar Technology America LLC
Derating behavior without fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
66
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.3.4
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
67
4 Sunny Boy without transformer
4.4
4.4.1
SMA Solar Technology America LLC
SB 5000TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.3 %
95.1 %
94.3 %
20 %
95.6 %
96.3 %
96.0 %
30 %
95.9 %
96.7 %
96.5 %
50 %
95.7 %
96.8 %
96.6 %
75 %
95.2 %
96.5 %
96.4 %
100 %
94.6 %
96.1 %
96.0 %
68
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.4.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.1 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
175 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.4 %
95.5 %
95.2 %
20 %
95.8 %
96.7 %
96.6 %
30 %
96.1 %
97.0 %
97.0 %
50 %
95.9 %
97.1 %
97.1 %
75 %
95.4 %
96.8 %
96.9 %
100 %
94.8 %
96.5 %
96.6 %
Technical Information
WKG-Derating-US-TI-en-15
69
4 Sunny Boy without transformer
4.4.3
SMA Solar Technology America LLC
Derating behavior without fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
70
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.4.4
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
71
4 Sunny Boy without transformer
4.5
4.5.1
SMA Solar Technology America LLC
SB 6000TLUS-12
Efficiency at 208 V AC
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
97.6 %
97.4 %
96.5 %
20 %
98.4 %
98.2 %
97.6 %
30 %
98.6 %
98.4 %
97.9 %
50 %
98.5 %
98.3 %
98.0 %
75 %
98.4 %
98.1 %
97.9 %
100 %
97.9 %
97.7 %
97.6 %
72
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.5.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
98.7 %
Californian efficiency, ηCEC
98.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
97.4 %
97.4 %
96.5 %
20 %
98.4 %
98.3 %
97.6 %
30 %
98.7 %
98.5 %
98.1 %
50 %
98.6 %
98.6 %
98.3 %
75 %
98.5 %
98.5 %
98.3 %
100 %
98.3 %
98.1 %
98.1 %
Technical Information
WKG-Derating-US-TI-en-15
73
4 Sunny Boy without transformer
4.5.3
SMA Solar Technology America LLC
Derating behavior at 208 V AC
SB 6000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
4.5.4
Derating behavior at 240 V AC
SB 6000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
74
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.6
4.6.1
SB 6000TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
97.0 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
210 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.5 %
94.1 %
93.3 %
20 %
96.0 %
96.4 %
95.9 %
30 %
96.3 %
96.8 %
96.5 %
50 %
96.3 %
97.0 %
96.8 %
75 %
96.0 %
96.9 %
96.7 %
100 %
95.6 %
96.7 %
96.5 %
Technical Information
WKG-Derating-US-TI-en-15
75
4 Sunny Boy without transformer
4.6.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.4 %
Californian efficiency, ηCEC
97.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
210 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
95.0 %
95.6 %
94.5 %
20 %
96.3 %
97.0 %
96.5 %
30 %
96.5 %
97.2 %
96.9 %
50 %
96.4 %
97.4 %
97.1 %
75 %
96.0 %
97.3 %
97.1 %
100 %
95.7 %
96.9 %
96.9 %
76
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.6.3
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
77
4 Sunny Boy without transformer
4.7
4.7.1
SMA Solar Technology America LLC
SB 7000TLUS-12
Efficiency at 208 V AC
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
97.8 %
97.7 %
96.9 %
20 %
98.6 %
98.3 %
97.8 %
30 %
98.6 %
98.4 %
98.0 %
50 %
98.4 %
98.3 %
98.0 %
75 %
98.2 %
97.9 %
97.8 %
100 %
97.6 %
97.5 %
97.4 %
78
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.7.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
98.7 %
Californian efficiency, ηCEC
98.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
97.7 %
97.8 %
96.8 %
20 %
98.5 %
98.4 %
97.8 %
30 %
98.7 %
98.5 %
98.2 %
50 %
98.6 %
98.2 %
98.3 %
75 %
98.4 %
98.3 %
98.2 %
100 %
98.0 %
97.8 %
97.9 %
Technical Information
WKG-Derating-US-TI-en-15
79
4 Sunny Boy without transformer
4.7.3
SMA Solar Technology America LLC
Derating behavior at 208 V AC
SB 7000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
4.7.4
Derating behavior at 240 V AC
SB 7000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
80
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.8
4.8.1
SB 7000TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
210 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.2 %
93.1 %
91.7 %
20 %
95.9 %
96.2 %
95.8 %
30 %
96.2 %
96.6 %
96.3 %
50 %
96.2 %
96.8 %
96.7 %
75 %
95.9 %
96.7 %
96.6 %
100 %
95.5 %
96.5 %
96.4 %
Technical Information
WKG-Derating-US-TI-en-15
81
4 Sunny Boy without transformer
4.8.2
SMA Solar Technology America LLC
Efficiency at 240 V AC
Maximum efficiency, ηmax
96.8 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
230 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.9 %
94.2 %
94.7 %
20 %
96.2 %
96.4 %
96.1 %
30 %
96.4 %
96.7 %
96.4 %
50 %
96.3 %
96.8 %
96.7 %
75 %
96.9 %
96.7 %
96.7 %
100 %
95.2 %
96.3 %
96.4 %
82
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
4.8.3
4 Sunny Boy without transformer
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
Technical Information
WKG-Derating-US-TI-en-15
83
4 Sunny Boy without transformer
4.9
4.9.1
SMA Solar Technology America LLC
SB 7700TL-US-22
Efficiency at 208 V AC
Maximum efficiency, ηmax
96.6 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
210 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.9 %
94.2 %
94.7 %
20 %
96.2 %
96.4 %
96.1 %
30 %
96.4 %
96.7 %
96.4 %
50 %
96.3 %
96.8 %
96.7 %
75 %
95.9 %
96.7 %
96.7 %
100 %
95.2 %
96.3 %
96.4 %
84
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.9.2
Efficiency at 240 V AC
Maximum efficiency, ηmax
97.3 %
Californian efficiency, ηCEC
96.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
270 V
Rated input voltage
400 V
Maximum MPP
voltage
480 V
10 %
94.8 %
94.4 %
92.7 %
20 %
96.4 %
97.0 %
96.5 %
30 %
96.6 %
97.3 %
96.9 %
50 %
96.7 %
97.3 %
97.1 %
75 %
96.4 %
97.1 %
97.0 %
100 %
96.0 %
96.8 %
96.6 %
Technical Information
WKG-Derating-US-TI-en-15
85
4 Sunny Boy without transformer
4.9.3
SMA Solar Technology America LLC
Derating behavior with fan
Derating Behavior at 208 V AC
Derating Behavior at 240 V AC
86
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.10 SB 8000TLUS-12
4.10.1 Efficiency at 208 V AC
SB 8000TLUS-12
98
92
90
VPV = 300 V DC
88
VPV = 345 V DC
99
97
480
300
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
0.8
Output power / Rated power
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
98.0 %
97.9 %
97.1 %
20 %
98.6 %
98.4 %
97.9 %
30 %
98.6 %
98.4 %
97.9 %
50 %
98.4 %
98.2 %
98.0 %
75 %
98.0 %
97.8 %
97.7 %
100 %
97.2 %
97.2 %
97.2 %
Technical Information
WKG-Derating-US-TI-en-15
87
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.10.2 Efficiency at 240 V AC
SB 8000TLUS-12
98
92
90
VPV = 345 V DC
88
VPV = 379 V DC
99
97
480
345
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
97.9 %
98.0 %
97.0 %
20 %
98.5 %
98.5 %
98.0 %
30 %
98.6 %
98.5 %
98.3 %
50 %
98.6 %
98.6 %
98.3 %
75 %
98.3 %
98.2 %
98.1 %
100 %
97.8 %
97.5 %
97.7 %
88
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.10.3 Derating behavior at 208 V AC
SB 8000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
4.10.4 Derating behavior at 240 V AC
SB 8000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
89
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.11 SB 9000TLUS-12
4.11.1 Efficiency at 208 V AC
SB 9000TLUS-12
98
92
90
VPV = 300 V DC
88
VPV = 345 V DC
99
97
480
300
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
98.2 %
98.0 %
97.4 %
20 %
98.6 %
98.4 %
97.9 %
30 %
98.5 %
98.4 %
98.0 %
50 %
98.3 %
98.2 %
97.9 %
75 %
97.7 %
97.6 %
97.5 %
100 %
96.9 %
96.9 %
96.9 %
90
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.11.2 Efficiency at 240 V AC
SB 9000TLUS-12
98
92
90
VPV = 345 V DC
88
VPV = 379 V DC
99
97
480
345
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
0.8
Output power / Rated power
Maximum efficiency, ηmax
98.7 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
98.0 %
98.1 %
97.2 %
20 %
98.7 %
98.6 %
98.1 %
30 %
98.7 %
98.6 %
98.3 %
50 %
98.5 %
98.5 %
98.3 %
75 %
98.1 %
97.9 %
98.0 %
100 %
97.6 %
97.4 %
97.6 %
Technical Information
WKG-Derating-US-TI-en-15
91
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.11.3 Derating behavior at 208 V AC
SB 9000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
4.11.4 Derating behavior at 240 V AC
SB 9000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
92
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.12 SB 10000TLUS-12
4.12.1 Efficiency at 208 V AC
SB 10000TLUS-12
98
92
90
VPV = 300 V DC
88
VPV = 345 V DC
99
97
480
300
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
0.8
Output power / Rated power
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
345 V
Maximum MPP
voltage
480 V
10 %
98.3 %
98.1 %
97.5 %
20 %
98.6 %
98.4 %
98.0 %
30 %
98.5 %
98.3 %
98.0 %
50 %
98.3 %
98.0 %
97.9 %
75 %
97.5 %
97.4 %
97.3 %
100 %
96.5 %
96.6 %
96.7 %
Technical Information
WKG-Derating-US-TI-en-15
93
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.12.2 Efficiency at 240 V AC
SB 10000TLUS-12
98
92
90
VPV = 345 V DC
88
VPV = 379 V DC
99
97
480
345
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.7 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
98.3 %
98.2 %
97.4 %
20 %
98.7 %
98.5 %
98.2 %
30 %
98.6 %
98.6 %
98.3 %
50 %
98.5 %
98.4 %
98.3 %
75 %
97.9 %
97.7 %
97.8 %
100 %
97.3 %
97.1 %
97.3 %
94
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.12.3 Derating behavior at 208 V AC
SB 10000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
4.12.4 Derating behavior at 240 V AC
SB 10000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
95
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.13 SB 11000TLUS-12
4.13.1 Efficiency at 240 V AC
SB 11000TLUS-12
98
92
90
VPV = 345 V DC
88
VPV = 379 V DC
99
97
480
345
VPV = 480 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.7 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
345 V
Rated input voltage
379 V
Maximum MPP
voltage
480 V
10 %
98.4 %
98.3 %
97.6 %
20 %
98.7 %
98.5 %
98.2 %
30 %
98.6 %
98.3 %
98.3 %
50 %
98.4 %
98.3 %
98.2 %
75 %
97.8 %
97.5 %
97.7 %
100 %
97.0 %
96.8 %
97.1 %
96
WKG-Derating-US-TI-en-15
Technical Information
4 Sunny Boy without transformer
SMA Solar Technology America LLC
4.13.2 Derating behavior at 240 V AC
SB 11000TLUS-12
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 345 V DC
VPV = 475 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
97
5 Sunny Tripower
5
SMA Solar Technology America LLC
Sunny Tripower
5.1
STP 12000TL-US-10
5.1.1
Efficiency at 277 V AC
STP 12000TL-US-10
98
92
90
VPV = 300 V DC
88
VPV = 675 V DC
99
97
800
300
VPV = 800 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.2 %
Californian efficiency, ηCEC
97.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
675 V
Maximum MPP
voltage
800 V
10 %
92.9 %
94.9 %
94.2 %
20 %
95.8 %
96.9 %
97.2 %
30 %
96.5 %
97.5 %
97.7 %
50 %
96.7 %
97.8 %
98.0 %
75 %
96.6 %
97.8 %
98.2 %
100 %
96.5 %
97.8 %
98.2 %
98
WKG-Derating-US-TI-en-15
Technical Information
5 Sunny Tripower
SMA Solar Technology America LLC
5.1.2
Derating behavior at 277 V AC
STP 12000TL-US-10
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 675 V DC
VPV = 800 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
99
5 Sunny Tripower
5.2
SMA Solar Technology America LLC
STP 15000TL-US-10
5.2.1
Efficiency at 277 V AC
STP 15000TL-US-10
98
92
90
VPV = 300 V DC
88
VPV = 675 V DC
99
97
800
300
VPV = 800 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.2 %
Californian efficiency, ηCEC
97.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
300 V
Rated input voltage
675 V
Maximum MPP
voltage
800 V
10 %
93.9 %
95.5 %
95.6 %
20 %
96.2 %
97.2 %
97.5 %
30 %
96.7 %
97.8 %
97.9 %
50 %
96.7 %
97.8 %
98.2 %
75 %
96.5 %
97.8 %
98.2 %
100 %
96.3 %
97.8 %
98.2 %
100
WKG-Derating-US-TI-en-15
Technical Information
5 Sunny Tripower
SMA Solar Technology America LLC
5.2.2
Derating behavior at 277 V AC
STP 15000TL-US-10
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 300 V DC
0.2
VPV = 675 V DC
VPV = 800 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
101
5 Sunny Tripower
5.3
SMA Solar Technology America LLC
STP 20000TL-US-10
5.3.1
Efficiency at 277 V AC
STP 20000TL-US-10
98
92
90
VPV = 380 V DC
88
VPV = 695 V DC
99
97
800
380
VPV = 800 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.5 %
Californian efficiency, ηCEC
97.5 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
380 V
Rated input voltage
695 V
Maximum MPP
voltage
800 V
10 %
95.2 %
97.2 %
96.5 %
20 %
97.0 %
98.3 %
97.9 %
30 %
97.2 %
98.5 %
98.1 %
50 %
97.1 %
98.5 %
98.2 %
75 %
96.9 %
97.8 %
98.2 %
100 %
96.7 %
97.7 %
98.0 %
102
WKG-Derating-US-TI-en-15
Technical Information
5 Sunny Tripower
SMA Solar Technology America LLC
5.3.2
Derating behavior at 277 V AC
STP 20000TL-US-10
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 380 V DC
0.2
VPV = 695 V DC
VPV = 800 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
103
5 Sunny Tripower
5.4
SMA Solar Technology America LLC
STP 24000TL-US-10
5.4.1
Efficiency at 277 V AC
STP 24000TL-US-10
98
92
90
VPV = 450 V DC
88
VPV = 712 V DC
99
97
800
450
VPV = 800 V DC
VMPP [V]
86
0.0
0.2
0.4
0.6
0.8
* weighted in accordance with CEC-operating points
94
weighted Eta* [%]
Efficiency [%]
96
1.0
Output power / Rated power
Maximum efficiency, ηmax
98.5 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
450 V
Rated input voltage
712 V
Maximum MPP
voltage
800 V
10 %
96.1 %
97.5 %
96.9 %
20 %
97.4 %
98.3 %
98.0 %
30 %
97.4 %
98.5 %
98.2 %
50 %
97.3 %
98.5 %
98.2 %
75 %
97.1 %
98.4 %
98.1 %
100 %
96.9 %
98.3 %
97.9 %
104
WKG-Derating-US-TI-en-15
Technical Information
5 Sunny Tripower
SMA Solar Technology America LLC
5.4.2
Derating behavior at 277 V AC
STP 24000TL-US-10
Output power / Rated power
1.0
0.8
0.6
0.4
VPV = 450 V DC
0.2
VPV = 712 V DC
VPV = 800 V DC
20/68
30/86
40/104
50/122
60/140
Ambient temperature [°C/°F]
Technical Information
WKG-Derating-US-TI-en-15
105
5 Sunny Tripower
5.5
5.5.1
SMA Solar Technology America LLC
STP 30000TL-US-10
Efficiency at 277 V AC
Maximum efficiency, ηmax
98.6 %
Californian efficiency, ηCEC
98.0 %
Efficiency Profile
Standardized output
power
Efficiency
Minimum MPP
voltage
500 V
Rated input voltage
720 V
Maximum MPP
voltage
800 V
10%
98.6%
97.6%
97.0%
20%
97.7%
98.4%
98.1%
30%
97.9%
98.7%
98.5%
50%
98.0%
98.6%
98.4%
75%
97.8%
98.5%
98.3%
100%
97.6%
98.3%
98.1%
106
WKG-Derating-US-TI-en-15
Technical Information
SMA Solar Technology America LLC
5.5.2
5 Sunny Tripower
Derating behavior at 277 V AC
Technical Information
WKG-Derating-US-TI-en-15
107
SMA Solar Technology
www.SMA-Solar.com
Download