www.sylvania.com QUICKTRONIC® PROStart® T8 QUICKSTEP® Bi-Level Dimming Systems Lamp Striation Control Low Ballast Factor Q HES T 8 PSL BI-LEVEL High Efficiency Series Lamp / Ballast Guide Primary Systems 32W T8 - OCTRON® lamps 1 or 2 lamp QHES2x32T8/UNV PSL-SC Also operates: FBO32, FBO31, FO25, FBO24, FO17, FBO16 & energy saving equivalents Key System Features • Q UICKSTEP Stepped Switching, bi-level dimming (0.77 BF to 0.25 BF) • High Efficiency Systems – over 90% efficient • NEMA Premium Electronic Ballast Program compliant • California Title 24 compliant • PROStart Programmed Rapid Start • Extends lamp life • LSC (Lamp Striation Control) • Universal input voltage (120-277V) • RoHS Compliant • Lead-free solder and manufacturing process Application Information SYLVANIA QUICKTRONIC PROStart T8 QUICKSTEP ballasts are ideally suited for: • • • • • • • • Office Schools Commercial Retail Occupancy sensor usage Building control systems Institutional Load shedding ECS263R2 - 8/2012 SYLVANIA QUICKTRONIC High Efficiency PROStart T8 QUICKSTEP Bi-Level Dimming ballasts are programmed rapid start electronic ballasts that will easily switch from 100% to 50% power with standard wall switches. The ballast operates linear and U-bend equivalent T8 lamps at high efficiency. QUICKSTEP bi-level step dimming ballasts are specifically designed to meet California’s Energy Efficiency Standards (Title 24*) for multilevel lighting controls (Section 131). The combined lamp and ballast system offers a high efficiency system for T8 luminaires along with high performance features that are standard on SYLVANIA High Efficiency Series ballasts. The QUICKTRONIC PROStart QUICKSTEP ballasts are RoHS Compliant featuring lead-free solder and manufacturing process and meet the requirements for the NEMA Premium Electronic Ballast System Information SYLVANIA QUICKTRONIC PROStart QUICKSTEP High Efficiency (QHES) ballasts operate from 120V through 277V, eliminating “wrong voltage” wiring errors and reducing the number of models in inventory by 50%. QUICKTRONIC QHE PROStart ballast delivers an optimized programmed rapid start technology which extends T8 lamp life and allows over 100,000 switching cycles for occupancy sensor and building control systems applications. These ballasts have two AC line inputs in addition to the neutral wire. These AC line inputs must be connected to the same phase of the line voltage. The two line inputs can be configured to provide a bi-level light output system by wiring with two switches. When both switches are on, the lamps operate at full light output. When either switch is off, the lamps operate in a dimmed mode and the ballast wattage is reduced by 50%. Alternatively, the ballasts can be controlled by occupancy sensors allowing for customized zone controls and various energy saving configurations. For additional information on this program go to: www.cee1.org or www.nema.org. program. The NEMA Premium program promotes the use of high efficiency T8 electronic ballasts by meeting or exceeding the Ballast Efficiency Factors, (BEF) established by the CEE, (Consortium for Energy Efficiency). *California’s Energy Efficiency Standards 2008 Title 24 Section 131. % Relative Lamp Input Mean Mean % % Life Lamp & Power Initial System Light System Energy @3hrs/ Ballast Type BF (W) LPW Lumens Output Power Savings Start 2-FO32/700 QTP2x32 ISL 0.78 51 86 3930 100%100% 0% 100% 2-FO32/XPS QHES2x32 PSL 0.77 Full Power 48 99 4490 114% 94% 6% 150% 2-FO32/XPS QHES2x32 PSL 0.25 50% Power 24 65 1455 37% 47% 53% 150% 180% % Relative Light Output % System Wattage % Lamp Life 160% 6% Energy Savings 140% 114% 120% 100% 150% 150% 100% 100% 100% 94% 53% Energy Savings 80% 60% 47% 37% 40% 20% 2-FO32/700 QTP2x32 ISL 2-FO32/XPS QHES2x32 PSL Full Power 2-FO32/XPS QHES2x32 PSL 50% Power Low Ballast Factor SPECIFICATION DATA Catalog # Date Project Prepared by T8 QUICKSTEP Type ® High Efficiency Comments Performance Guide Input Rated BallastInitial Mean Input System1 Item OSRAM SYLVANIA Current Lamp Lumens No. of Factor System System Power (W) Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens 120V 277V (lm/W) 4775 1550 4390 1425 4195 1365 3810 1240 3390 1100 2155 730 2420 775 2225 715 2125 680 1930 620 1715 550 1090 365 4490 1455 4125 1340 3945 1280 3585 1165 3185 1035 2025 685 2275 730 2090 670 2000 640 1815 580 1615 515 1025 340 48 24 46 23 42 22 38 21 37 20 24 16 25 15 24 15 22 14 20 13 20 14 14 12 BEF 2 48 99 1.60 24 65 1.04 46 95 1.67 23 62 1.09 42 1001.83 22 621.14 38 1002.03 21 591.19 37 922.08 20 551.25 24 903.21 16 461.63 25 973.12 15 521.67 24 933.25 15 481.67 22 973.55 14 491.79 20 973.90 13 481.92 20 863.90 14 391.79 14 785.57 12 302.17 2: BEF (Ballast Efficiency Factor) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest input power) Installation Notes • Install in accordance with National & Local Electric Code • Ground Ballast Case • The AC line inputs must be connected to the same phase of the line voltage • DO NOT CONNECT two separate phases of line voltage to the input of QUICKSTEP ballasts, the ballast will be damaged and not covered by warranty LAMP LAMP LAMP Yellow Yellow Neutral S1 S2 Black Black White Yellow Yellow Blue Blue BALLAST Line Red Red Neutral 1-Lamp QHES (QUICKSTEP) Full light output (full power) S1 & S2 closed (on) Bi-level mode (50% power) S1 or S2 open (off) S1 S2 Black Black White Blue Blue BALLAST Red Red 2-Lamp QHES (QUICKSTEP) Full light output (full power) S1 & S2 closed (on) Bi-level mode (50% power) S1 or S2 open (off) Special Note: This ballast has LSC (Lamp Striation Control) which minimizes or eliminates striating lamps. Under certain conditions however, T8 lamps may still striate. This condition will not affect the life or light output of the lamp and will not affect the ballast. Consult lamp manufacturers for additional details. Dimensions: Overall: 9.5" L x 1.68" W x 1.18" H Mounting: 8.90" Product Weight: 1.6 lbs each (approx) Item Number QUICKTRONIC High Efficiency Step Dim, QUICKSTEP (bi-level) Number of Lamps (2) Height 8.70 mm Slot Width Mounting Length Wiring: LAMP Leads only (no connectors provided) Length S1 49158 QHES 2 x 32T8 / UNV PSL Line- SC S2 Neutral Yellow Yellow Blue Blue Black BALLAST Enclosure Size: Small Can Red Black Starting Type/PROStart/LowRed Ballast Factor White Line Voltage (120-277V) Primary Lamp Wattage & Type SYLVANIA, OCTRON, QUICKSTEP, PROStart, SUPERSAVER, the system solution and QUICK60+ are registered trademarks of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM AG. NEMA Premium is a registered trademark of National Electrical Manufacturers Association. Specifications Data based on F32T8 Starting Method: Programmed Rapid Start Ballast Factor: 0.77/0.25 (see table) Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.7 Starting Temp:3 0 °F/-18°C for OCTRON T8 lamps; 32°F/0°C in dimmed mode; 60°F/16°C for SUPERSAVER® T8 lamps Input Frequency: 50/60 Hz THD: <10% (full power) <20% (@50% power) Power Factor: >97% (full power) Voltage Range: ±10% Q HES T 8 PSL BI-LEVE L QHES 2x32T8/UNV PSL-SC (@100%) 0.40/0.18 FO32XPS 3100 2 0.77 49158 Banded Pack (@50%) 0.20/0.09 FO32XPS 3100 2 0.25 (@100%) 0.39/0.17 FO30SS 2850 2 0.77 (@50%) 0.20/0.09 FO30SS 2850 2 0.25 (@100%)0.36/0.16 FO28SS 2725 2 0.77 (@50%)0.19/0.09 FO28SS 2725 2 0.25 (@100%)0.32/0.14 FO25SS 2475 2 0.77 (@50%)0.18/0.08 FO25SS 2475 2 0.25 (@100%)0.31/0.14 FO25XPS 2200 2 0.77 (@50%)0.17/0.08 FO25XPS 2200 2 0.25 (@100%) 0.20/0.10 FO17XPS 1400 2 0.77 (@50%) 0.13/0.07 FO17XPS 1400 2 0.26 (@100%)0.21/0.10 FO32XPS 3100 1 0.78 (@50%)0.12/0.06 FO32XPS 3100 1 0.25 (@100%)0.20/0.09 FO30SS 2850 1 0.78 (@50%) 0.12/0.06 FO30SS 2850 1 0.25 (@100%)0.18/0.09 FO28SS 2725 1 0.78 LAMP (@50%)0.12/0.06 FO28SS 2725 1 0.25 LAMP (@100%)0.17/0.07 FO25SS 2475 1 0.78 (@50%)0.11/0.05 FO25SS 2475 1 0.25 Yellow (@100%)0.16/0.08 0.78 Blue FO25XPS 2200 1 Yellow (@50%)0.12/0.06 0.25 Blue FO25XPS 2200 1 S1 (@100%) 0.11/0.06 FO17XPS 1400 1 0.78 Black BALLAST Line Red Black S2 (@50%) 0.09/0.05 FO17XPS 1400 1 0.26 Red Whiteeach, (add “-B” to description). 1: System Efficacy is based on the lowest Input Power Neutral Banded Pack contains 10 pieces Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QHE QUICKSTEP PROStart ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max. Case Temp. (5 yr. warranty) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating RoHS Compliant 4 ANSI C62.41 Cat A. Transient Protection Remote Mounting (Max. wire length from ballast case to lampholder): up to 7 feet for all lamps except 4 feet for energy saving T8 lamps (keep blue wires short, ie. lamp(s) attached to the blue leads to remain in the fixture that houses the ballast). Lamp Seasoning: For optimal performance, fluorescent lamps may require seasoning for up to 12 hours prior to low temperature starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice — Lamp Seasoning for Fluorescent Dimming Systems 3 Operation below 50°F/10°C may affect light output or lamp operation – see “Low Temp. Starting” definition. 4 Complies with European Union Restriction of Hazardous Substances Directive. System Life / Warranty QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. ©2012 OSRAM SYLVANIA High Efficiency QUICKSTEP® (Bi-Level) T8 Dimming Systems (120-277V) Line PSL