O N PT E IO W N S MY F-440 & F-450N SERIES O N O F-440 and F-450N Series flowmeters have Polysulfone meter C E & E bodies and adapters, corrosion resistant internal parts and, are offered L in a number of calibrations and configurations. Styles for either in-line STY or panel mount installation are available, as well as units with integral flow adjustment valves. Specially Equipped units have Hastelloy Float Guides and floats of Hastelloy, Teflon or Noryl/Teflon (float material depends on meter calibration). SolarMetersTM feature either brass sweat or brass threaded adapters. — Height: 7 1/12 ” Width: 2” F-450N IN-LINE MODEL DIMENSIONS Model F-45375, Model F-45376, Model F-45500 — Height: 8 7/8" Model F-45750 — Height: 10" Width: 2" F-44250LH-6 F-44250LH-8 F-44375LH-6 F-44375LH-8 F-44376LH-6 F-44376LH-8 F-44500LH-6 F-44500LH-8 F-44750LH-12 CALIBRATION GPM LPM ADAPTER SIZE 0.025 to 0.250 0.1 to 1.0 3/8" 0.025 to 0.250 0.1 to 1.0 1/2" 0.1 to 1.0 0.4 to 4.0 3/8" 0.1 to 1.0 0.4 to 4.0 1/2" 0.2 to 2.0 0.75 to 7.5 3/8" 0.2 to 2.0 0.75 to 7.5 1/2" 0.5 to 5.0 1.8 to 18.0 3/8" 0.5 to 5.0 1.8 to 18.0 1/2" 1.0 to 10 5.0 to 37.5 3/4" Calibration GPH F-44330LH-6 3.0 to 30 3/8" F-44330LH-8 3.0 to 30 1/2" F-44560LH-6 5.0 to 60 3/8" F-44560LH-8 5.0 to 60 1/2" Models listed above: “LH” (in-line, #316 SS float material) MODEL VARIATIONS *LH *LHE *LEA Width: 2" F-450N GUIDELINES MODEL NUMBER F-440 GUIDELINES MODEL NUMBER F-440NEA WITH 90° ADAPTERS AND ADJUSTMENT VALVE Model F-44750 F-451 WITH PROTECTIVE SHIELD F-440 IN-LINE MODEL DIMENSIONS Model F-44250, Model F-44330, Model F-44375, Model F-44376, Model F-44500, Model F-44560 Height: 6 3/16” Width: 1 11/16” F-452 HIGH CAPACITY SERIES F-450N SPECIFICATIONS: Temperature 212°F/100°C @ 0 pressure Pressure 150 psi/10.3 Bar @ 70°F/21°C Full scale accuracy ± 5% Meter Body material Polysulfone Adapters material Polysulfone O-rings Viton Float material #316 SS (Hastelloy C, Teflon & PVC materials available) Max. pressure drop 2 psi F-451 WITH 90° ADAPTERS For Style, Versatility and Value, Choose the F-440 & F-450N Series Flowmeters. F-440 SPECIFICATIONS: Temperature 212°F/100°C @ 0 pressure Pressure 150 psi/10.3 Bar @ 70°F/21°C Full scale accuracy ± 5% Meter Body material Polysulfone Adapters material Polysulfone O-rings Viton Float material #316 SS (Hastelloy C, Teflon & PVC materials available depending on calibration) Max. pressure drop 2 psi F-450N IN-LINE UNIT F-440NEA WITH 90° ADAPTERS AND ADJUSTMENT VALVE High Performance Polysulfone Meter Body and Adapters Viton® o-ring Seals Water and Wastewater Treatment Equipment Corrosion and Wear Resistant Internal Parts Pollution Monitoring and Control Equipment Configurations for both In-Line and Panel Mount Installation Reverse Osmosis Equipment Requirements Chemical Procession Optional Integral Flow Adjustment Valve Passive Solar Systems Permanent Screen Printed Scales Film and X-ray Processing Equipment Calibrated Floats . . . Wherever a Tough, Accurate Flowmeter is Dual scale: gallons per minute and Liters per minute (GPM/LPM) required Single scale for gallons per hour (GPH) F-450N IN-LINE UNIT F-440 & F-450N APPLICATIONS INCLUDE: F-440 & F-450N FEATURES INCLUDE: Blue-White ® M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT = In-Line units (flow through). = 90° Elbows for Panel Mount Installation. = 90° Elbows for Panel Mount Installation and Adjustable Valve. *LHK = In-line units specially equipped with Hastelloy C, PVC or Teflon float and guide rod (material is dependent on scale range). *LKEA = 90° Elbows for Panel Mount Installation, Adjustable Valve and Specially Equipped units. *LHB = Units with Brass Adapters. (3/8” units F/NPT replace the suffix -6 with a -7, 1/2” units SWEAT use -8 1/2” units M/NPT use a -9, 3/4” units M/NPT replace -12 with -13). CALIBRATION GPM LPM F-45375LHN-6 0.1 to 1.0 F-45375LHN-8 0.1 to 1.0 F-45376LHN-6 0.2 to 2.0 F-45376LHN-8 0.2 to 2.0 F-45500LHN-6 0.5 to 5.0 F-45500LHN-8 0.5 to 5.0 F-45500LHN-12 0.5 to 5.0 F-45750LHN-12 1.0 to 10 Models listed above “LHN” (in-line 0.4 to 4.0 0.4 to 4.0 1.0 to 7.5 1.0 to 7.5 2.0 to 20.0 2.0 to 20.0 2.0 to 20.0 4.0 to 40.0 units) ADAPTER SIZE 3/8" F/NPT 1/2" M/NPT 3/8" F/NPT 1/2" M/NPT 3/8" F/NPT 1/2" M/NPT 3/4" M/NPT 3/4" M/NPT Calibration SCFM (Air) F-45376GHN-6 F-45376GHN-8 F-45750GHN-12 Models listed above “GHN” air calibration) MODEL VARIATIONS: *LHN *LHE *LEA *LHKN *LKEA *LHBN *GHN *GHNE *GEA 1 to 12 3/8" F/NPT 1 to 12 1/2" M/NPT 4 to 48 3/4" M/NPT (In-line, #316 SS float material, Blue-White’s High Performance Polysulfone Flowmeters combine Quality Materials of Construction, pride-of-workmanship and over 45 years of manufacturing experience. All backed by excellent customer service. F-451, F-452, F-450N and F-440 Series Flowmeters have meter body and adapter construction of injection molded Polysulfone. Polysulfone is a highly engineered thermoplastic that is suited to many applications where glass and metal flowmeters are typically used. Blue-White’s Polysulfone flowmeters are amber in color and feature a textured surface on the back of the meter body that diffuses ambient light, for easy meter reading. Blue-White offers many OEM options, including private labeling and packaging. In addition, we are pleased to quote on custom calibrations, alternate materials and styling modifications. = In-Line units (flow through) = 90° Elbows for Panel Mount Installation = 90° Elbows and Adjustment Valve for Panel Mount Installation = In-line units specially equipped with Hastelloy C, guide rods and either Hastelloy C or Teflon Float. = 90° Elbows, Adjustment Valve and Specially Equipped units for Panel Mount Installation. = Units with Brass Adapters (suffix -8=1/2" sweat; -9=1/2" MPT; -12=3/4" sweat; -13=3/4" MPT) = In-line units calibrated for air = 90° Elbows for Panel Mount Installation, calibrated for air = 90° Elbows for Panel Mount Installation with adjustable valve calibrated for air. Blue-White ® AUTHORIZED REPRESENTATIVE 5300 BUSINESS DRIVE HUNTINGTON BEACH, CA 92649 USA PHONE: FAX: E-MAIL: URL: 80000-252 REV. 6 714 / 893-8529 714 / 894-9492 sales@blue-white.com www.bluwhite.com © BLUE-WHITE 04/03 F-452 SERIES THE F-451 SERIES NEW NS O I OPT PERFORMANCE QUALITY and VERSATILITY consider the Specially Equipped F-451 Series. In addition to meter body and adapter construction of tough Polysulfone, Specially Equipped meters have float guides of Hastelloy C, and floats of either Hastelloy C or Teflon, depending on calibration. F-451 APPLICATIONS INCLUDE: Water & Wastewater Treatment Equipment Pollution Treatment & Regulating Equipment D.I., R.O. and Ultrapure Water Systems Solar Heating Chemical Procession Filtration Systems Chemigation . . . and many more Pressure vs Temperature STANDARD MODELS Height: 14 1/2” Width: 3 3/16” W/PROTECTIVE SHIELD Height: 14 1/2” Width: 3 5/16” W/90° ADAPTERS Height: 17” Centers: 15” 1”F/NPT POLYSULFONE Adapters CALIBRATION F-451006LHN F-451001LHN F-451002LHN F-451003LHN F-451004LHN GPM LPM 0.5 to 6 1.0 to 10 2.0 to 20 3.0 to 30 4.0 to 40 – 4 to 40 7.5 to 75 12 to 115 15 to 155 1" 1" 1" 1" 1" F/NPT F/NPT F/NPT F/NPT F/NPT ORDERING GUIDELINES CALIBRATION GPM LPM 0.5 to 6 1.0 to 10 2.0 to 20 3.0 to 30 4.0 to 40 – 4 to 40 7.5 to 75 12 to 115 15 to 155 CALIBRATION SCFM (AIR) ADAPTER SIZE F-451002GHN 8 to 80 F-451002GHN-24 8 to 80 MODEL VARIATIONS: *LHN *LHNE Viton® is a registered trademark of DuPont. ADAPTER SIZE Water and Wastewater Treatment Equipment Pollution Monitoring and Control Equipment Reverse Osmosis Equipment Chemical Procession D.I. and Ultrapure Water Systems Film and X-ray Processing Equipment 1 1/2" F/NPT PVC Adapters MODEL NUMBER F-451006LHN-24 F-451001LHN-24 F-451002LHN-24 F-451003LHN-24 F-451004LHN-24 * The factory does not guarantee their flowmeters for use with liquids other than water. Customers are required to do their own compatibility testing. Request Kit #70000-718, at no charge. F-452 APPLICATIONS INCLUDE: ORDERING GUIDELINES MODEL NUMBER F-452 BENEFITS INCLUDE: A one piece impact, heat and chemical resistant* Polysulfone meter body Optional Polycarbonate Protective Shield Calibrations in gallons per minute, liters per minute and SCFM Easy to read, permanent silk screened scales #316 Stainless Steel floats and float guides Pressure vs Temperature 2” F/NPT Polysulfone adapters Viton® o-ring seals Accuracy ± 2 % Easy to assemble and install F-451 BENEFITS INCLUDE: A Heat and Chemical* resistant meter body of injection molded Polysulfone Optional Polycarbonate Protective Shield Floats are #316 S.S. or Teflon, depending on calibration Many calibrations are offered in GPM, LPM and SCFM Permanent, easy to read screen printed scales 1” F/NPT Polysulfone adapters, or, 1 1/2” PVC adapters (depending on model ordered) Viton® o-ring seals Accuracy ± 3% Optional 90° Adapters DIMENSIONS INSIST ON THE BEST . . . THE F-452 SERIES FROM BLUE-WHITE F-452 HIGH CAPACITY SERIES F-451 SPECIALLY EQUIPPED — For Harsh Environment installations*, Blue-White’s Premier Polysulfone flowmeter . . . The F-452. This High Performance Flowmeter features top quality materials of construction and superior styling, combined with excellent accuracy and repeatability. Design features include a tough, one piece meter body of injection molded Polysulfone. Polysulfone is a highly engineered thermoplastic well suited to many applications. Additional benefits include: Injection molded 2” F/NPT Polysulfone adapters; floats that are carefully engineered for excellent accuracy; and permanent screen printed scales that are positioned directly in front of the float for easy reading. F-452 HIGH CAPACITY SERIES WITH PROTECTIVE SHIELD F-451 WITH PROTECTIVE SHIELD — The F-451 may be ordered with a Protective Shield constructed of clear, durable Polycarbonate. F-451 FOR IN-LINE INSTALLATION F-451 W/PROTECTIVE SHIELD Flowmeter with great accuracy and repeatability, order the F-451 equipped with 1” M/NPT 90° panel mount adapters. Adapters are constructed of injection molded Polysulfone. F-451 FOR PANEL MOUNT INSTALLATION High Performance Materials of Construction combine with Functional Styling and Versatility, to make the F-451 Series a terrific value. The F-451 Series is available with a number of optional design features including protective shields and 90° adapters. In addition, Blue-White’s modern machine shop and engineering departments work together to meet special OEM requirements. F-451 WITH 90° ADAPTERS — For applications requiring a Panel Mount and STYLE ADAPTER SIZE 1 1 1 1 1 1/2" 1/2" 1/2" 1/2" 1/2" 1" F/NPT 1 1/2" F/NPT = In-Line units (flow through) = 90° Elbows for Panel Mount Installation (M/NPT all models but the F-451006 F/NPT) *LHNC = Units with Polycarbonate Shield *LHKN = In-line units specially equipped with Hastelloy C, PVC or Teflon float and guide rod depending on scale range. *LHBPN = Units with Brass F/NPT Adapters *LHBSN = Units with Brass Sweat Adapters *GHN = In-line units calibrated for air F/NPT F/NPT F/NPT F/NPT F/NPT F-452 HIGH CAPACITY FLOWMETER MODEL NUMBER F-452020LH F-452060LH F-452080LH F-452100LH F-452130LH F-452175LH CALIBRATION GPM CALIBRATION LPM ADAPTER SIZE 2.0 to 20 6.0 to 60 10 to 80 5.0 to 100 15 to 130 20 to 175 — 30 to 230 40 to 300 20 to 380 60 to 500 75 to 675 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT DIMENSIONS Height: 18 7/8” Width: 4 1/2” Models listed above are “LH” (in-line, #316 SS) F-452 OPTIONS INCLUDE: MODEL VARIATIONS: LHK = In-line, Hastelloy C or Teflon float material LHC = Units with Polycarbonate shield LHKC = Units with Polycarbonate shield The F-452 series flowmeter is available Specially Equipped with Hastelloy C float guides and floats. This option greatly enhances the chemical resistance of the flowmeters*. In addition, Blue-White is pleased to quote on special materials and calibrations, as well as private labeling, to volume purchasers. F-452040GH F-452250GH Calibration SCFM (AIR) 4.0 to 40 30 to 230 Models listed above are “GH” (in-line, #316 SS) Viton® is a registered trademark of DuPont. 2” F/NPT 2” F/NPT Blue-White’s F-452 Series Variable Area Flowmeter is now offered with optional Polycarbonate shield. This shield helps protect the flowmeter NEW an from accidental breakage. * The factory does not guarantee their flowmeters for use with liquids other than water. Customers are required to do their own compatibility testing. Request Kit #70000-718, at no charge. F-452 SERIES THE F-451 SERIES NEW NS O I OPT PERFORMANCE QUALITY and VERSATILITY consider the Specially Equipped F-451 Series. In addition to meter body and adapter construction of tough Polysulfone, Specially Equipped meters have float guides of Hastelloy C, and floats of either Hastelloy C or Teflon, depending on calibration. F-451 APPLICATIONS INCLUDE: Water & Wastewater Treatment Equipment Pollution Treatment & Regulating Equipment D.I., R.O. and Ultrapure Water Systems Solar Heating Chemical Procession Filtration Systems Chemigation . . . and many more Pressure vs Temperature STANDARD MODELS Height: 14 1/2” Width: 3 3/16” W/PROTECTIVE SHIELD Height: 14 1/2” Width: 3 5/16” W/90° ADAPTERS Height: 17” Centers: 15” 1”F/NPT POLYSULFONE Adapters CALIBRATION F-451006LHN F-451001LHN F-451002LHN F-451003LHN F-451004LHN GPM LPM 0.5 to 6 1.0 to 10 2.0 to 20 3.0 to 30 4.0 to 40 – 4 to 40 7.5 to 75 12 to 115 15 to 155 1" 1" 1" 1" 1" F/NPT F/NPT F/NPT F/NPT F/NPT ORDERING GUIDELINES CALIBRATION GPM LPM 0.5 to 6 1.0 to 10 2.0 to 20 3.0 to 30 4.0 to 40 – 4 to 40 7.5 to 75 12 to 115 15 to 155 CALIBRATION SCFM (AIR) ADAPTER SIZE F-451002GHN 8 to 80 F-451002GHN-24 8 to 80 MODEL VARIATIONS: *LHN *LHNE Viton® is a registered trademark of DuPont. ADAPTER SIZE Water and Wastewater Treatment Equipment Pollution Monitoring and Control Equipment Reverse Osmosis Equipment Chemical Procession D.I. and Ultrapure Water Systems Film and X-ray Processing Equipment 1 1/2" F/NPT PVC Adapters MODEL NUMBER F-451006LHN-24 F-451001LHN-24 F-451002LHN-24 F-451003LHN-24 F-451004LHN-24 * The factory does not guarantee their flowmeters for use with liquids other than water. Customers are required to do their own compatibility testing. Request Kit #70000-718, at no charge. F-452 APPLICATIONS INCLUDE: ORDERING GUIDELINES MODEL NUMBER F-452 BENEFITS INCLUDE: A one piece impact, heat and chemical resistant* Polysulfone meter body Optional Polycarbonate Protective Shield Calibrations in gallons per minute, liters per minute and SCFM Easy to read, permanent silk screened scales #316 Stainless Steel floats and float guides Pressure vs Temperature 2” F/NPT Polysulfone adapters Viton® o-ring seals Accuracy ± 2 % Easy to assemble and install F-451 BENEFITS INCLUDE: A Heat and Chemical* resistant meter body of injection molded Polysulfone Optional Polycarbonate Protective Shield Floats are #316 S.S. or Teflon, depending on calibration Many calibrations are offered in GPM, LPM and SCFM Permanent, easy to read screen printed scales 1” F/NPT Polysulfone adapters, or, 1 1/2” PVC adapters (depending on model ordered) Viton® o-ring seals Accuracy ± 3% Optional 90° Adapters DIMENSIONS INSIST ON THE BEST . . . THE F-452 SERIES FROM BLUE-WHITE F-452 HIGH CAPACITY SERIES F-451 SPECIALLY EQUIPPED — For Harsh Environment installations*, Blue-White’s Premier Polysulfone flowmeter . . . The F-452. This High Performance Flowmeter features top quality materials of construction and superior styling, combined with excellent accuracy and repeatability. Design features include a tough, one piece meter body of injection molded Polysulfone. Polysulfone is a highly engineered thermoplastic well suited to many applications. Additional benefits include: Injection molded 2” F/NPT Polysulfone adapters; floats that are carefully engineered for excellent accuracy; and permanent screen printed scales that are positioned directly in front of the float for easy reading. F-452 HIGH CAPACITY SERIES WITH PROTECTIVE SHIELD F-451 WITH PROTECTIVE SHIELD — The F-451 may be ordered with a Protective Shield constructed of clear, durable Polycarbonate. F-451 FOR IN-LINE INSTALLATION F-451 W/PROTECTIVE SHIELD Flowmeter with great accuracy and repeatability, order the F-451 equipped with 1” M/NPT 90° panel mount adapters. Adapters are constructed of injection molded Polysulfone. F-451 FOR PANEL MOUNT INSTALLATION High Performance Materials of Construction combine with Functional Styling and Versatility, to make the F-451 Series a terrific value. The F-451 Series is available with a number of optional design features including protective shields and 90° adapters. In addition, Blue-White’s modern machine shop and engineering departments work together to meet special OEM requirements. F-451 WITH 90° ADAPTERS — For applications requiring a Panel Mount and STYLE ADAPTER SIZE 1 1 1 1 1 1/2" 1/2" 1/2" 1/2" 1/2" 1" F/NPT 1 1/2" F/NPT = In-Line units (flow through) = 90° Elbows for Panel Mount Installation (M/NPT all models but the F-451006 F/NPT) *LHNC = Units with Polycarbonate Shield *LHKN = In-line units specially equipped with Hastelloy C, PVC or Teflon float and guide rod depending on scale range. *LHBPN = Units with Brass F/NPT Adapters *LHBSN = Units with Brass Sweat Adapters *GHN = In-line units calibrated for air F/NPT F/NPT F/NPT F/NPT F/NPT F-452 HIGH CAPACITY FLOWMETER MODEL NUMBER F-452020LH F-452060LH F-452080LH F-452100LH F-452130LH F-452175LH CALIBRATION GPM CALIBRATION LPM ADAPTER SIZE 2.0 to 20 6.0 to 60 10 to 80 5.0 to 100 15 to 130 20 to 175 — 30 to 230 40 to 300 20 to 380 60 to 500 75 to 675 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT 2” F/NPT DIMENSIONS Height: 18 7/8” Width: 4 1/2” Models listed above are “LH” (in-line, #316 SS) F-452 OPTIONS INCLUDE: MODEL VARIATIONS: LHK = In-line, Hastelloy C or Teflon float material LHC = Units with Polycarbonate shield LHKC = Units with Polycarbonate shield The F-452 series flowmeter is available Specially Equipped with Hastelloy C float guides and floats. This option greatly enhances the chemical resistance of the flowmeters*. In addition, Blue-White is pleased to quote on special materials and calibrations, as well as private labeling, to volume purchasers. F-452040GH F-452250GH Calibration SCFM (AIR) 4.0 to 40 30 to 230 Models listed above are “GH” (in-line, #316 SS) Viton® is a registered trademark of DuPont. 2” F/NPT 2” F/NPT Blue-White’s F-452 Series Variable Area Flowmeter is now offered with optional Polycarbonate shield. This shield helps protect the flowmeter NEW an from accidental breakage. * The factory does not guarantee their flowmeters for use with liquids other than water. Customers are required to do their own compatibility testing. Request Kit #70000-718, at no charge. O N PT E IO W N S MY F-440 & F-450N SERIES O N O F-440 and F-450N Series flowmeters have Polysulfone meter C E & E bodies and adapters, corrosion resistant internal parts and, are offered L in a number of calibrations and configurations. Styles for either in-line STY or panel mount installation are available, as well as units with integral flow adjustment valves. Specially Equipped units have Hastelloy Float Guides and floats of Hastelloy, Teflon or Noryl/Teflon (float material depends on meter calibration). SolarMetersTM feature either brass sweat or brass threaded adapters. — Height: 7 1/12 ” Width: 2” F-450N IN-LINE MODEL DIMENSIONS Model F-45375, Model F-45376, Model F-45500 — Height: 8 7/8" Model F-45750 — Height: 10" Width: 2" F-44250LH-6 F-44250LH-8 F-44375LH-6 F-44375LH-8 F-44376LH-6 F-44376LH-8 F-44500LH-6 F-44500LH-8 F-44750LH-12 CALIBRATION GPM LPM ADAPTER SIZE 0.025 to 0.250 0.1 to 1.0 3/8" 0.025 to 0.250 0.1 to 1.0 1/2" 0.1 to 1.0 0.4 to 4.0 3/8" 0.1 to 1.0 0.4 to 4.0 1/2" 0.2 to 2.0 0.75 to 7.5 3/8" 0.2 to 2.0 0.75 to 7.5 1/2" 0.5 to 5.0 1.8 to 18.0 3/8" 0.5 to 5.0 1.8 to 18.0 1/2" 1.0 to 10 5.0 to 37.5 3/4" Calibration GPH F-44330LH-6 3.0 to 30 3/8" F-44330LH-8 3.0 to 30 1/2" F-44560LH-6 5.0 to 60 3/8" F-44560LH-8 5.0 to 60 1/2" Models listed above: “LH” (in-line, #316 SS float material) MODEL VARIATIONS *LH *LHE *LEA Width: 2" F-450N GUIDELINES MODEL NUMBER F-440 GUIDELINES MODEL NUMBER F-440NEA WITH 90° ADAPTERS AND ADJUSTMENT VALVE Model F-44750 F-451 WITH PROTECTIVE SHIELD F-440 IN-LINE MODEL DIMENSIONS Model F-44250, Model F-44330, Model F-44375, Model F-44376, Model F-44500, Model F-44560 Height: 6 3/16” Width: 1 11/16” F-452 HIGH CAPACITY SERIES F-450N SPECIFICATIONS: Temperature 212°F/100°C @ 0 pressure Pressure 150 psi/10.3 Bar @ 70°F/21°C Full scale accuracy ± 5% Meter Body material Polysulfone Adapters material Polysulfone O-rings Viton Float material #316 SS (Hastelloy C, Teflon & PVC materials available) Max. pressure drop 2 psi F-451 WITH 90° ADAPTERS For Style, Versatility and Value, Choose the F-440 & F-450N Series Flowmeters. F-440 SPECIFICATIONS: Temperature 212°F/100°C @ 0 pressure Pressure 150 psi/10.3 Bar @ 70°F/21°C Full scale accuracy ± 5% Meter Body material Polysulfone Adapters material Polysulfone O-rings Viton Float material #316 SS (Hastelloy C, Teflon & PVC materials available depending on calibration) Max. pressure drop 2 psi F-450N IN-LINE UNIT F-440NEA WITH 90° ADAPTERS AND ADJUSTMENT VALVE High Performance Polysulfone Meter Body and Adapters Viton® o-ring Seals Water and Wastewater Treatment Equipment Corrosion and Wear Resistant Internal Parts Pollution Monitoring and Control Equipment Configurations for both In-Line and Panel Mount Installation Reverse Osmosis Equipment Requirements Chemical Procession Optional Integral Flow Adjustment Valve Passive Solar Systems Permanent Screen Printed Scales Film and X-ray Processing Equipment Calibrated Floats . . . Wherever a Tough, Accurate Flowmeter is Dual scale: gallons per minute and Liters per minute (GPM/LPM) required Single scale for gallons per hour (GPH) F-450N IN-LINE UNIT F-440 & F-450N APPLICATIONS INCLUDE: F-440 & F-450N FEATURES INCLUDE: Blue-White ® M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT M/NPT = In-Line units (flow through). = 90° Elbows for Panel Mount Installation. = 90° Elbows for Panel Mount Installation and Adjustable Valve. *LHK = In-line units specially equipped with Hastelloy C, PVC or Teflon float and guide rod (material is dependent on scale range). *LKEA = 90° Elbows for Panel Mount Installation, Adjustable Valve and Specially Equipped units. *LHB = Units with Brass Adapters. (3/8” units F/NPT replace the suffix -6 with a -7, 1/2” units SWEAT use -8 1/2” units M/NPT use a -9, 3/4” units M/NPT replace -12 with -13). CALIBRATION GPM LPM F-45375LHN-6 0.1 to 1.0 F-45375LHN-8 0.1 to 1.0 F-45376LHN-6 0.2 to 2.0 F-45376LHN-8 0.2 to 2.0 F-45500LHN-6 0.5 to 5.0 F-45500LHN-8 0.5 to 5.0 F-45500LHN-12 0.5 to 5.0 F-45750LHN-12 1.0 to 10 Models listed above “LHN” (in-line 0.4 to 4.0 0.4 to 4.0 1.0 to 7.5 1.0 to 7.5 2.0 to 20.0 2.0 to 20.0 2.0 to 20.0 4.0 to 40.0 units) ADAPTER SIZE 3/8" F/NPT 1/2" M/NPT 3/8" F/NPT 1/2" M/NPT 3/8" F/NPT 1/2" M/NPT 3/4" M/NPT 3/4" M/NPT Calibration SCFM (Air) F-45376GHN-6 F-45376GHN-8 F-45750GHN-12 Models listed above “GHN” air calibration) MODEL VARIATIONS: *LHN *LHE *LEA *LHKN *LKEA *LHBN *GHN *GHNE *GEA 1 to 12 3/8" F/NPT 1 to 12 1/2" M/NPT 4 to 48 3/4" M/NPT (In-line, #316 SS float material, Blue-White’s High Performance Polysulfone Flowmeters combine Quality Materials of Construction, pride-of-workmanship and over 45 years of manufacturing experience. All backed by excellent customer service. F-451, F-452, F-450N and F-440 Series Flowmeters have meter body and adapter construction of injection molded Polysulfone. Polysulfone is a highly engineered thermoplastic that is suited to many applications where glass and metal flowmeters are typically used. Blue-White’s Polysulfone flowmeters are amber in color and feature a textured surface on the back of the meter body that diffuses ambient light, for easy meter reading. Blue-White offers many OEM options, including private labeling and packaging. In addition, we are pleased to quote on custom calibrations, alternate materials and styling modifications. = In-Line units (flow through) = 90° Elbows for Panel Mount Installation = 90° Elbows and Adjustment Valve for Panel Mount Installation = In-line units specially equipped with Hastelloy C, guide rods and either Hastelloy C or Teflon Float. = 90° Elbows, Adjustment Valve and Specially Equipped units for Panel Mount Installation. = Units with Brass Adapters (suffix -8=1/2" sweat; -9=1/2" MPT; -12=3/4" sweat; -13=3/4" MPT) = In-line units calibrated for air = 90° Elbows for Panel Mount Installation, calibrated for air = 90° Elbows for Panel Mount Installation with adjustable valve calibrated for air. Blue-White ® AUTHORIZED REPRESENTATIVE 5300 BUSINESS DRIVE HUNTINGTON BEACH, CA 92649 USA PHONE: FAX: E-MAIL: URL: 80000-252 REV. 6 714 / 893-8529 714 / 894-9492 sales@blue-white.com www.bluwhite.com © BLUE-WHITE 04/03