39231 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection (former GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide GE Consumer & Industrial Power Protection Redline ED.04 Comfort Functions Just feel protected www.gepowercontrols.com www.ge.com/eu/powerprotection Redline - Modulair DIN-rail devices ED.04 GE imagination at work GE imagination at work GE POWER CONTROLS International Sales Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 90 E-mail: gepcbel@gepc.ge.com GE imagination at work GE imagination at work GE imagination at work GE imagination at work 680803 Ref. R/2260/E/X 15.0 Ed. 11/06 © Copyright GE Power Controls 2006 Redline Modular DIN-rail devices and residential enclosures Circuit Protection A People Protection B Add-on Devices C Comfort Functions D Busbars E Enclosures F Record Plus G Numerical Index X Redline D.2 Switches & Push-buttons - Aster D.4 Indication Lamp - Aster D.6 Contactors - Contax D.8 Relays - Contax R D.10 Impulse Switches - Pulsar S D.14 Staircase Switches - Pulsar TS D.16 Time Relays - Pulsar T D.18 Analogue Time Switches - Classic D.20 Digital Time Switches - Galax D.22 Time Switches - 72x72 Classic and Galax D.24 Light Sensitive Switches - Galax LSS D.26 Transformers - Series T D.28 Measurement Instruments - Series MT D.32 Priority relays - PR D.34 Surge Arresters - SurgeGuard D.36 Dimensional drawings Circuit Protection A People Protection B Add-on Devices C Comfort Functions D Busbars E Enclosures F Record Plus G Numerical Index X protected D.1 Redline Switches & Push-buttons Comfort functions Aster Applications Switching of lighting and heating in homes, shops, offices, warehouses, factories, hospitals, etc. Features Function Manual control of all kinds of electrical devices. A Approvals (1) B C Wide range with respect to available contact combinations and switching capacity. Mains disconnect switches and switches with change-over contact and off position available. Compact (4-pole in 1 module) with high switching capacity due to double interruption per path. All switches are sealable through padlock or by means of a lock. The terminals are equipped with captive Pozidriv screws and have IP20 protection degree. Mains disconnect switches accepts auxiliary contacts CA. Standards D E BS EN VDE BS EN VDE BS EN Switches 16/32A Mains disconnect switches 40-100 Rotary switches (1) Depending on type. 60669-1 0632 Part 1 60947-3 0632 Part 101 60947-3 F Performance G Nominal rated current Usable as mains disconnect switch Nominal breaking capacity at 415V, cos ϕ =0.95 Nominal breaking capacity at 415V, cos ϕ =0.65 Nominal voltage single pole devices Nominal voltage multipole devices Maximum allowed current during less than 1 s. Mechanical service life (complete on-off-cycle) Electrical service life, cos ϕ = 0.95, Un and In Short-circuit resistance with upfront fuses Gg/gL 100A (nominal) (peak) Protection degree Screws Terminal capacity: min max X Auxiliary contacts More technical data Dimensions D.2 pg. C.4 to C.5 website pg D.36 Push-buttons Switches 16A | 32A Rotary switches 32-40-63A Mains disconnect switches 40-63-80-100A 16A no 240V >20000 >20000 4.5kA (nominal) 3kA (peak) IP20 Pozidriv 1 1x1.5mm2 1x10mm2 no 1.25xIn 240V 415V >20000 >20000 | >5000 4.5kA (nominal) 3kA (peak) IP20 Pozidriv 1 1x1.5mm2 1x10mm2 yes 8xIn 8xIn 240/415V >10000 >1500 15kA (nominal) 10kA (peak) IP20 Pozidriv 2 1x2.5mm2 1x25mm2 yes 3xIn 3xIn 240/415V 240/415V 2kA >20000 >1500 16kA (nominal) 7kA (peak) IP20 Pozidriv 2 1x6mm2 1x50mm2 Redline Aster - Switches & push-buttons Contact combination Number of modules Cat. No. Ref. No. Pack. 40A/240V 40A/415V 40A/415V 40A/415V 63A/240V 63A/415V 63A/415V 63A/415V 1NO 2NO 3NO 4NO 1NO 2NO 3NO 4NO 1 2 3 4 1 2 3 4 AST M 40 10 AST M 40 20 AST M 40 30 AST M 40 40 AST M 63 10 AST M 63 20 AST M 63 30 AST M 63 40 666614 666615 666616 666617 666562 666563 666564 666565 12 6 4 3 12 6 4 3 80A/240V 80A/415V 80A/415V 80A/415V 100A/240V 100A/415V 100A/415V 100A/415V 1NO 2NO 3NO 4NO 1NO 2NO 3NO 4NO 1 2 3 4 1 2 3 4 AST M 80 10 AST M 80 20 AST M 80 30 AST M 80 40 AST M 100 10 AST M 100 20 AST M 100 30 AST M 100 40 666566 666567 666568 666569 666558 666559 666560 666561 12 6 4 3 12 6 4 3 32A/415V 32A/415V 32A/415V 32A/415V 40A/415V 40A/415V 40A/415V 40A/415V 63A/415V 63A/415V 63A/415V 63A/415V 2NO 3NO 3NO+NC 4NO 2NO 3NO 3NO+NC 4NO 2NO 3NO 3NO+NC 4NO 4 4 4 4 4 4 4 4 4 4 4 4 AST R 32 20 AST R 32 30 AST R 32 3N AST R 32 40 AST R 40 20 AST R 40 30 AST R 40 3N AST R 40 40 AST R 63 20 AST R 63 30 AST R 63 3N AST R 63 40 666574 666575 666576 666577 666578 666579 666580 666581 666582 666583 666584 666585 1 1 1 1 1 1 1 1 1 1 1 1 16A/240V 16A/240V 16A/415V 16A/415V 16A/415V 16A/415V 16A/240V 16A/240V 1NO 2NO 3NO 4NO 3NO 4NO 1CO 2CO 1 1 1 1 2 2 1 1 AST S 16 10 AST S 16 20 AST S 16 30 AST S 16 40 AST S 16 30 2 AST S 16 40 2 AST S 16 1 AST S 16 2 666587 666589 666590 666593 666591 666592 666586 666588 12 12 12 12 6 6 12 12 32A/240V 32A/240V 32A/415V 32A/415V 32A/415V 32A/415V 32A/240V 32A/240V 1NO 2NO 3NO 4NO 3NO 4NO 1CO 2CO 1 1 1 1 2 2 1 1 AST S 32 10 AST S 32 20 AST S 32 30 AST S 32 40 AST S 32 30 2 AST S 32 40 2 AST S 32 1 AST S 32 2 666595 666597 666599 666600 666598 666601 666594 666596 12 12 12 12 6 6 12 12 Switch with signal lamp 16A/240V 16A/240V 32A/240V 32A/240V 1NO 2NO 1NO 2NO 1 1 1 1 AST SL 16 10 AST SL 16 20 AST SL 32 10 AST SL 32 20 666602 666603 666604 666605 12 12 12 12 Changeover switches with zero position 16A/240V 16A/240V 32A/240V 32A/240V 1CO 2CO 1CO 2CO 1 1 1 1 AST SZ 16 1 AST SZ 16 2 AST SZ 32 1 AST SZ 32 2 666606 666607 666608 666609 12 12 12 12 Push-button 16A/240V 16A/240V 16A/240V 1NC 1NO 1NO 1NC 1 1 1 AST P 16 01 AST P 16 10 AST P 16 11 666570 666571 666572 12 12 12 16A/240V 1NO 1 AST PL 16 10 666573 12 AST R ES E AST R ES S 666555 666556 1 1 AST R TS 666557 1 Mains disconnect switch Rotary switch Changeover switches Push-button with signal lamp Aster Nominal current A B C D E F G X Accessories for rotary switches Extension shaft Sealing piece 238 mm with emergency handle 238 mm with standard handle 4 D.3 Redline Indication Lamp Aster Function Comfort functions Status visualisation. Applications Mainly used to visualise the status of a (sub)part of the installation, heater, motor, fan, pump etc. Features Available in different voltages and with different coloured lenses. A Performance B C Nominal voltage 12V 24V 230V Own consumption Lamp Lens colours 120mA Incandescent lamp Red, green, orange and transparent IP20 Pozidriv 1 1x1.5mm2 1x10mm2 / 2x4mm2 85mA Incandescent lamp Red, green, orange and transparent IP20 Pozidriv 1 1x1.5mm2 1x10mm2 / 2x4mm2 2.2mA Neon lamp Red, green, orange and transparent IP20 Pozidriv 1 1x1.5mm2 1x10mm2 / 2x4mm2 Protection degree Screws Terminal capacity: min max D E Socket-outlets F MSC G Standards BS EN C61112-1, NF C61-303 (86), IEC 60884-1 X Approvals (1) (1) Depending on type. Performance Nominal current More technical data Dimensions D.4 website pg D.36, D.37 Nominal voltage Operating temperature Protection degree Screws Terminal capacity: min max 16A 250V -20 ... +55°C IP20 Pozidriv 2 1x1 mm2 1x6 mm2 or 2x2.5 mm2 Redline Aster - Indication lamp Colour Number of modules - - 1 Nominal operating voltage Colour 12V 24V 230V Lampholder Cat. No. Ref. No. Pack. AST B 666347 12 Number of modules Cat. No. Ref. No. Pack. - - AST B 12 AST B 24 AST B 230 666340 666342 666341 12 12 12 Green Amber Red Blue White - AST LG 230V AST LA 230V AST LR 230V AST LB 230V AST LW 230V 666876 666874 666877 666875 666878 10 10 10 10 10 Transparent Green Orange Red - AST L CL AST L GN AST L OR AST L RD 666343 666344 666345 666346 12 12 12 12 Accessories Lamp Lamp LED E10 Lens 235V 235V 235V 235V 235V / / / / / - Aster and MSC Nominal operating voltage A B C D E MSC - Socket-outlets Nominal current Nominal voltage Number of modules Cat. No. Ref. No. Pack. Edged with child protection 16A 250V 2.5 MSC SEP 666501 4 Edged without child protection 16A 250V 2.5 MSC SE 666499 4 F G X Pin with child protection 16A 250V 2.5 MSC SPP 666502 4 D.5 Redline Contactors Contax Comfort functions Applications Switching of lighting, heating-equipment, motors for pumps and fans, ... Day and night contactors are used mainly in combination with dual-tariff applications to allow high-energy-loads (i.e. electrical water heaters, accumulation heaters) only to consume energy during the low-tariff period. A forced-on, forced-off, auto-switch allows to overrule the normal operation of the DN-contactor at all times. Features Function Contactors are electromechanically controlled switches used to control single or multi-phase (high) power loads while the control itself can be (very) low power. A B Except for the 20A version, all contactors have DC coils, resulting in an absolutely noise-free, real silent operation: 50 or 60Hz noise generation by the contactor is impossible. As all DC coil contactors have an internal diode rectifier bridge, they all can be operated by both DC and AC power supplies. The built-in varistor protects the coil against an overvoltage of up to 5kV. The switch position of the contactor is visualised through an indicator flag. The loss-proof safety terminals are equipped with Pozidriv screws and have IP20 protection degree. Add-on auxiliary contacts as well as spacers and sealing pieces are available. Standards C IEC 60947-4-1, BS EN 60947-4-1, IEC 61095, BS EN 61095. Approval VDE. Performance D Rated switching capacity Contacts E Switching capacity for different loads Rated insulation voltage Rated operational voltage Switching-on capacity cos ϕ = 0.65 at 380-400V 3phase cos ϕ = 0.95 at 220-230V 1phase Switching-off capacity cos ϕ = 0.65 at 380-400V 3phase cos ϕ = 0.95 at 220-230V 1phase Fuse type GL for short-circuit protection Ohmic loss per contact at In Maximum switching frequency AC1 / AC7a Maximum switching frequency AC3 / AC7b Mechanical service life Electrical service life AC1 / AC7a Electrical service life AC3 / AC7b Screws Terminal capacity: min max F G X 20A 24A 40A 63A More technical information see T4 400V 250V 500V 440V 500V 440V 500V 440V 100A 90A - 220A - 300A - 80A 20A 1.0W 300/h 600/h 106 150000 150000 Pozidriv 1 1x1 mm2 1x10mm2 or 2x4 mm2 72A 35A 1.5W 300/h 600/h 106 150000 500000 Pozidriv 1 1x1 mm2 1x10mm2 or 2x4 mm2 176A 240A 63A 80A 3.0W 6.0W 300/h 300/h 600/h 600/h 106 106 150000 150000 170000 240000 Pozidriv 2 Pozidriv 2 1x1.5 mm2 1x1.5 mm2 1x25mm2 or 2x10 mm2 1x25mm2 or 2x10 mm2 85 ... 110%xUn 50 or 60Hz -25 ... +55°C(1) 8.0VA / 5.0W 3.2VA / 1.2W 9 ... 12 ms 10 ... 12 ms Pozidriv 1 1x1 mm2 1x4mm2 or 2x2.5 mm2 85 ... 110%xUn DC, 40 ... 450Hz -25 ... +55°C(1) 4VA / 4W 4VA / 4W < 40 ms < 40 ms Pozidriv 1 1x1 mm2 1x4mm2 or 2x2.5 mm2 85 ... 110%xUn DC, 40 ... 450Hz -25 ... +55°C(1) 5VA / 5W 5VA / 5W < 40 ms < 40 ms Pozidriv 1 1x1 mm2 1x4mm2 or 2x2.5 mm2 Magnetic control system Control voltage range Rated operating frequency Operating temperature range Maximum pull-in coil power loss Maximum holding coil power loss Switching-on delay Switching-off delay Screws Terminal capacity: min max 85 ... 110%xUn DC, 40 ... 450Hz -25 ... +55°C(1) 65VA / 65W 4.2VA / 4.2W < 40 ms < 40 ms Pozidriv 1 1x1 mm2 1x4mm2 or 2x2.5 mm2 (1) Remark: If several contactors are mounted next to each-other and the time of operation exceeds 1 hour and the ambient temperature rises above 40°C, a 1/2-module spacer must be added every second contactor (I.e. contactor contactor spacer contactor contactor spacer contactor contactor etc.) D.6 Redline Contax - Contactors Contact combination Coil voltage AC/DC Number of modules 20A 20A 20A 20A 20A 20A 20A 20A 20A 1NO 1NC 1NO 1NC 2NC 2NC 2NO 2NO 2NO 2NO 2NO 24V 230V 24V 230V 12V 24V 48V 230V 240V AC AC AC AC AC AC AC AC AC 1 1 1 1 1 1 1 1 1 24A 24A 24A 24A 24A 24A 24A 24A 24A 24A 24A 2NO 2NC 2NO 2NC 3NO 3NO 4NC 4NC 4NO 4NO 4NO 4NO 4NO 24V 230V 24V 230V 24V 230V 12V 24V 48V 230V 240V AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC 40A 40A 40A 40A 40A 40A 40A 40A 40A 40A 2NC 2NO 3NO 3NO 4NO 4NO 4NO 4NO 2NO 4NO 230V 230V 24V 230V 12V 24V 48V 230V 24V 240V 4 NO 63A 63A 63A 63A 63A 2NC 4NO 4NO 2NO 4NO Contactor Day and Night 20A Contactor 1 NO 1 NC 2 NC 2 NO 2 NO 2 NC 3 NO 4 NC Cat. No. Ref. No. Pack. CTX 20 11 024 A CTX 20 11 230 A CTX 20 02 024 A CTX 20 02 230 A CTX 20 20 012 A CTX 20 20 024 A CTX 20 20 048 A CTX 20 20 230 A CTX 20 20 240 A 666127 666126 666129 666128 666130 666133 666134 666131 666132 12 12 12 12 12 12 12 12 12 2 2 2 2 2 2 2 2 2 2 2 CTX 24 22 024 U CTX 24 22 230 U CTX 24 30 024 U CTX 24 30 230 U CTX 24 04 024 U CTX 24 04 230 U CTX 24 40 012 U CTX 24 40 024 U CTX 24 40 048 U CTX 24 40 230 U CTX 24 40 240 U 666136 666135 666138 666137 666140 666139 666141 666144 666145 666142 666143 5 5 5 5 5 5 5 5 5 5 5 AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC 3 3 3 3 3 3 3 3 3 3 CTX 40 02 230 U CTX 40 20 230 U CTX 40 30 024 U CTX 40 30 230 U CTX 40 40 012 U CTX 40 40 024 U CTX 40 40 048 U CTX 40 40 230 U CTX 40 20 024 U CTX 40 40 240 U 666170 666146 666149 666148 666150 666153 666154 666151 666147 666152 3 3 3 3 3 3 3 3 3 3 230V 24V 230V 230V 240V AC/DC AC/DC AC/DC AC/DC AC/DC 3 3 3 3 3 CTX 63 02 230 U CTX 63 40 024 U CTX 63 40 230 U CTX 63 20 230 U CTX 63 40 240 U 666171 666158 666156 666155 666157 3 3 3 3 3 2NO 230V AC 1 CTX DN 20 20 230 A 666164 12 24A 24A 3NO 4NO 230V 230V AC/DC AC/DC 2 2 CTX DN 24 30 230 U CTX DN 24 40 230 U 666165 666166 5 5 40A 40A 40A 2NO 3NO 4NO 230V 230V 230V AC/DC AC/DC AC/DC 3 3 3 CTX DN 40 20 230 U CTX DN 40 30 230 U CTX DN 40 40 230 U 666167 666168 666169 3 3 3 Contax Nominal current A B C D 2 NO 3 NO E 4NO F Add-on auxiliary contact for 24-40-63A contactors Left mounting 1 NO 1 NC Nominal current Contact combination 6A 6A 1NO 1NC 2NO - - Number of modules Cat. No. Ref. No. Pack. 0.5 0.5 CTX 06 11 CTX 06 20 666162 666163 5 5 G X 2 NO Accessories Sealing piece Spacer Number of modules Cat. No. Ref. No. Pack. 2 3 CTX TS 2 CTX TS 3 666160 666159 3 3 0.5 CTX SP 666161 12 D.7 Redline Relays Contax R Comfort functions Applications Switching of lighting, heating, etc. Galvanic insulation of i.e. status signalisation lamps from a (high) power (high voltage) circuit . Galvanic insulation of PLC-inputs or outputs to avoid destruction through excessive voltage. Features Besides the normal operation through electrically energising the coil, manual operation is possible at all times. The switch position of the relay is visualised through an indicator flag. The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree. An add-on auxiliary contact as well as spacer are available. Function Relays are electromechanically controlled switches used to control low power loads. A B BSEN 60669-1, BSEN 60669-1, VDE 0632, VDE 0660-107, NBN C61-111, NF C61-810, VDE 0637, IEC 60669-1, IEC 60669-2-2, IEC 61095, BSEN 61095 Performance Rated switching capacity Contacts C 16A Contact spacing / material Spacing between control and load circuit Isolation voltage contact/contact Isolation voltage contact/magnetic system Switching capacity Incandescent lamp load Fluorescent lamp load, lead-lag circuit Fluorescent lamp load, inductive or capacitive Fluorescent lamp load, parallel compensated Electronic ballast load D E Inductive load, cos ϕ = 0.6 at 230V DC switching capacity Minimum contact load Maximum switching frequency Mechanical service life Electrical service life, cos ϕ = 1 (1) Electrical service life, cos ϕ = 0.6 (1) Electrical service life, 1000W incandescent lamp (1) Contact closing time Contact opening time Screws Terminal capacity: min max F G X Standards 3 mm/AgSnO2 > 6 mm 400V 400V 16A/250V; 10A/400V 10A (2300W) 16A (3500W) 10A (1300W) 4A (500W) 10A (2300W) ION ≤ 140A/10ms 10A (1300W) 100W 6V/50mA 1000/h >106 >105 > 2x104 >105 10 ... 20 ms 5 ... 15 ms Pozidriv 1 1x0.5mm2 1x6 mm2 or 2x2.5 mm2 Magnetic control system Control voltage range Relative duty/switching reliability Operating temperature range Maximum coil power loss at Un and In Maximum control line capacitance Screws Terminal control capacity: min max 0.9 ... 1.1xUn 100% -5 ... +50°C 6W/module 0.06µF (= ±200 m.) Pozidriv 1 1x0.5 mm2 1x4 mm2 or 2x2.5 mm2 (1) Guaranteed at maximum switching frequency. More technical data Dimensions D.8 website pg D.38 Redline Contax R - Relays Contact combination Coil voltage AC/DC Number of modules Cat. No. Ref. No. Pack. 16A 16A 16A 16A 16A 16A 16A 1NO 1NO 1NO 1NO 1NO 1NO 1NO 8V 12V 24V 48V 230V 12V 24V AC AC AC AC AC DC DC 1 1 1 1 1 1 1 CTX R 16 10 008 A CTX R 16 10 012 A CTX R 16 10 024 A CTX R 16 10 048 A CTX R 16 10 230 A CTX R 16 10 012 D CTX R 16 10 024 D 666489 666454 666458 666460 666456 666455 666459 12 12 12 12 12 12 12 16A 16A 16A 16A 16A 16A 16A 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 8V 12V 24V 48V 230V 12V 24V AC AC AC AC AC DC DC 1 1 1 1 1 1 1 CTX R 16 11 008 A CTX R 16 11 012 A CTX R 16 11 024 A CTX R 16 11 048 A CTX R 16 11 230 A CTX R 16 11 012 D CTX R 16 11 024 D 666491 666461 666465 666467 666463 666462 666466 12 12 12 12 12 12 12 16A 16A 16A 16A 16A 16A 16A 2NO 2NO 2NO 2NO 2NO 2NO 2NO 8V 12V 24V 48V 230V 12V 24V AC AC AC AC AC DC DC 1 1 1 1 1 1 1 CTX R 16 20 008 A CTX R 16 20 012 A CTX R 16 20 024 A CTX R 16 20 048 A CTX R 16 20 230 A CTX R 16 20 012 D CTX R 16 20 024 D 666490 666468 666472 666474 666470 666469 666473 12 12 12 12 12 1 12 16A 16A 16A 16A 16A 16A 16A 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 8V 12V 24V 48V 230V 12V 24V AC AC AC AC AC DC DC 2 2 2 2 2 2 2 CTX R 16 22 008 A CTX R 16 22 012 A CTX R 16 22 024 A CTX R 16 22 048 A CTX R 16 22 230 A CTX R 16 22 012 D CTX R 16 22 024 D 666492 666475 666479 666481 666477 666476 666480 1 6 6 6 6 1 6 16A 16A 16A 16A 16A 16A 16A 4NO 4NO 4NO 4NO 4NO 4NO 4NO 8V 12V 24V 48V 230V 12V 24V AC AC AC AC AC DC DC 2 2 2 2 2 2 2 CTX R 16 40 008 A CTX R 16 40 012 A CTX R 16 40 024 A CTX R 16 40 048 A CTX R 16 40 230 A CTX R 16 40 012 D CTX R 16 40 024 D 666493 666482 666486 666488 666484 666483 666487 5 6 6 6 6 6 6 Nominal current Number of modules Cat. No. Ref. No. Pack. 4A 0.5 PLS 04 11 666207 12 Contax R Nominal current A B C Auxiliary contact Auxiliary contact (left mounting) D E F G X Accessories Spacer Number of modules Cat. No. Ref. No. Pack. 0.5 PLS SP 666206 12 D.9 Redline Impulse Switches Comfort functions Pulsar S A B Function Performance Impulse switches are electromechanically or electronically controlled switches used to control single- or multi-phase medium-power loads while the control itself can be (very) low power. The device switches between 2 stable positions, each time a (brief) impulse energises its control circuit. Applications C D E F G X Mainly used for the switching of lighting and heating equipment and/or to obtain a simplified wiring in case the load needs to be controlled at reduced voltage and/or from more than 4 different places. Features Besides the normal operation through electrically energising the coil, manual operation is possible at all times. The switch position of the impulse switch is visualised through an indicator flag for the EM-version, or through an LED for the electronic version. The central command version was developed to force several devices at the same time to the on or off position, independently of the current status of each individual device. Also in this case, the possibility of operating the device locally remains. The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree. An add-on auxiliary contact, add-on central-command module and a spacer are available. Standards IEC 60669-1, IEC 60669-2-2, BS EN 60669-1, BS EN 60669-2-2 Rated switching capacity Contacts Contact spacing / material Spacing between control and load circuit Isolation voltage contact/contact Isolation voltage contact/magnetic system Switching capacity Incandescent lamp load Fluorescent lamp load, lead-lag circuit Fluorescent lamp load, inductive or capacitive Fluorescent lamp load, parallel compensated Electronic ballast load Inductive load, cos ϕ = 0.6 at 230V DC switching capacity Minimum contact load Maximum switching frequency Mechanical service life Electrical service life, cos ϕ = 1 (1) Electrical service life, cos ϕ = 0.6 (1) Electrical service life, 1000W incandescent lamp (1) Screws Terminal capacity: min max Magnetic control system Control voltage range Relative duty at rated voltage 1&2-pole/3&4-pole Maximum continuous time of coil excitation Minimum duration of command impulse / pause Operating temperature range Maximum load of illuminated push-buttons - Without parallel compensating capacitor - With 1µF/250V capacitor parallel to coil - With 2.2µF/250V capacitor parallel to coil Maximum coil power loss at Un and In Maximum control line capacitance Screws Terminal capacity: min max (1) Guaranteed at maximum switching frequency. More technical data Dimensions D.10 website pg D.38 Redline Pulsar S 10A 16A 25A 0.5 mm/AgCdO 10 3 mm 250V 400V 10A/250V 1000W 1000W 1000W Not allowed 700W; ION ≤ 70A/10 ms 650W 100W 4V/10mA 1000/h >107 >105 >104 >105 Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 3 mm/AgSnO2 > 6 mm 400V 400V 16A/250V; 10A/400V 10A (2300W) 16A (3500W) 10A (1300W) 4A (500W) 10A (2300W); ION ≤ 140A/10 ms 10A (1300W) 100W 6V/50mA 1000/h >106 >105 > 2x104 >105 Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 2x2 mm/AgSnO2 > 6 mm 400V 400V 25A/250V; 16A/400V 16A (3600W) 25A (5500W) 16A (2000W) 8A (1000W) 10A (2300W); ION ≤ 140A/10 ms 16A (2000W) 150W 12V/150mA 1000/h >106 >105 > 2x104 >105 Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 0.9 ... 1.1xUn 100% 50 ms / 800 ms -20 ... +50°C 0.9 ... 1.1xUn 100% / 60% 100% for 1&2 poles, 1h for 4 poles 50 ms / -5 ... +50°C 0.9 ... 1.1xUn 100% / 60% 100% for 1&2 poles, 1h for 4 poles 50 ms / -5 ... +50°C 30mA 3.5W Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 5mA 10mA 15mA 7W for 1 pole, 10 for 2 poles, 20 for 4 poles 0.06µF (= ±200 m.) Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 5mA 10mA 15mA 7W for 1 pole, 10 for 2 poles, 20 for 4 poles 0.06µF (= ±200 m.) Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 A B C D E F G X 1. Special care must be taken when connecting electromechanical impulse switches with central command. Terminals A1, B1 and C1 must be connected to the same voltage (I.e. live), whereas A2 must be connected to the opposite voltage (I.e. neutral). Incorrect connection I.e. different voltages on A1, B1 and C1 will destroy the central command circuit immediately after energising. 2. If several impulse switches are going to be permanently energised, please ensure that there is adequate ventilation in accordance with the power loss calculation. As a rule of thumb, use a 1/2 mod spacer every 2nd impulse switch when continuously energised. D.11 Redline Pulsar S - Impulse switches Comfort functions Electromechanical A B C D E F G X Electromechanical Step-by-step / Multi-circuit D.12 Nominal current Contact combination Coil voltage AC/DC Number of modules Ref. No. Pack. 16A 16A 16A 16A 16A 16A 16A 16A 1NO 1NO 1NO 1NO 1NO 1NO 1NO 1NO 8V 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC AC DC DC 1 1 1 1 1 1 1 1 PLS 16 10 008 A PLS 16 10 012 A PLS 16 10 024 A PLS 16 10 048 A PLS 16 10 230 A PLS 16 10 240 A PLS 16 10 012 D PLS 16 10 024 D 666330 666210 666214 666216 666212 666213 666211 666215 12 12 12 12 12 12 12 12 16A 16A 16A 16A 16A 16A 16A 16A 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 8V 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC AC DC DC 1 1 1 1 1 1 1 1 PLS 16 11 008 A PLS 16 11 012 A PLS 16 11 024 A PLS 16 11 048 A PLS 16 11 230 A PLS 16 11 240 A PLS 16 11 012 D PLS 16 11 024 D 666332 666217 666221 666223 666219 666220 666218 666222 12 12 12 12 12 12 12 12 16A 16A 16A 16A 16A 16A 16A 16A 2NO 2NO 2NO 2NO 2NO 2NO 2NO 2NO 8V 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC AC DC DC 1 1 1 1 1 1 1 1 PLS 16 20 008 A PLS 16 20 012 A PLS 16 20 024 A PLS 16 20 048 A PLS 16 20 230 A PLS 16 20 240 A PLS 16 20 012 D PLS 16 20 024 D 666331 666224 666228 666230 666226 666227 666225 666229 12 12 12 12 12 12 12 12 16A 16A 16A 16A 16A 16A 16A 16A 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 8V 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC AC DC DC 2 2 2 2 2 2 2 2 PLS 16 22 008 A PLS 16 22 012 A PLS 16 22 024 A PLS 16 22 048 A PLS 16 22 230 A PLS 16 22 240 A PLS 16 22 012 D PLS 16 22 024 D 666333 666231 666235 666237 666233 666234 666232 666236 6 6 6 6 6 6 6 6 16A 16A 16A 16A 16A 16A 16A 16A 4NO 4NO 4NO 4NO 4NO 4NO 4NO 4NO 8V 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC AC DC DC 2 2 2 2 2 2 2 2 PLS 16 40 008 A PLS 16 40 012 A PLS 16 40 024 A PLS 16 40 048 A PLS 16 40 230 A PLS 16 40 240 A PLS 16 40 012 D PLS 16 40 024 D 666334 666238 666242 666244 666240 666241 666239 666243 6 6 6 6 6 6 6 6 25A 25A 25A 25A 25A 25A 25A 1NO 1NO 1NO 1NO 1NO 1NO 1NO 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC DC DC 1 1 1 1 1 1 1 PLS 25 10 012 A PLS 25 10 024 A PLS 25 10 048 A PLS 25 10 230 A PLS 25 10 240 A PLS 25 10 012 D PLS 25 10 024 D 666245 666249 666251 666247 666248 666246 666250 12 12 12 12 12 12 12 25A 25A 25A 25A 25A 25A 25A 2NO 2NO 2NO 2NO 2NO 2NO 2NO 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC DC DC 1 1 1 1 1 1 1 PLS 25 20 012 A PLS 25 20 024 A PLS 25 20 048 A PLS 25 20 230 A PLS 25 20 240 A PLS 25 20 012 D PLS 25 20 024 D 666252 666256 666258 666254 666255 666253 666257 12 12 12 12 12 12 12 25A 25A 25A 25A 25A 25A 25A 4NO 4NO 4NO 4NO 4NO 4NO 4NO 12V 24V 48V 230V 240V 12V 24V AC AC AC AC AC DC DC 2 2 2 2 2 2 2 PLS 25 40 012 A PLS 25 40 024 A PLS 25 40 048 A PLS 25 40 230 A PLS 25 40 240 A PLS 25 40 012 D PLS 25 40 024 D 666259 666263 666265 666261 666262 666260 666264 6 6 6 6 6 6 6 16A 16A 16A 16A 1NO 1NO 1NO 1NO 1NO 1NO 1NO 1NO 12V 24V 48V 230V AC AC AC AC 1 1 1 1 PLS S 16 20 012 A PLS S 16 20 024 A PLS S 16 20 048 A PLS S 16 20 230 A 666316 666319 666320 666317 12 12 12 12 Cat. No. Redline Pulsar S - Impulse switches Electronic Central command Nominal current Contact combination Coil voltage AC/DC Number of modules Cat. No. Ref. No. Pack. 16A 1NO 12V-230V AC/DC 1 PLS C 10 10 230 U 666322 12 16A 1NO 1NC 12V-230V AC/DC 1 PLS C 10 11 230 U 666325 12 16A 2NO 12V-230V AC/DC 1 PLS C 10 20 230 U 666328 12 Add-on modules for electromechanical impulse switches Contact combination Coil voltage AC/DC Number of modules Cat. No. Ref. No. Pack. 4A 1NO 1NC - - 0.5 PLS 04 11 666207 12 Pulsar S Add-on auxiliary contact (left mounting) Nominal current A Accessories Spacer Number of modules Cat. No. Ref. No. Pack. 0.5 PLS SP 666206 12 B C D E F G X D.13 Redline Staircase Switches Pulsar TS Comfort functions Function A Push-button operated single-shot timer, switching the power to the load after the push-button has been pushed briefly, and switching off again after the presetted time has elapsed. Applications Lighting or ventilation of staircases, basements, halls, etc. Standards User adjustable time. Electromechanical or digital clockwork. Manual override off or on possible at all times. 3 or 4 wire wiring possible. Device with pre-extinction warning available. The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree. B C Features VDE 0632, BS EN 60669-1 More technical data Dimensions website pg D.39 Performance D PLT S EM PLT S EF 3mm/AgSnO2 400V 16A/250V 2300W 3500W 1300W 1000W 2300W; ION ≤ 140A/10ms 1300W 6V/50mA 0.5 … 5min. >5x104 >5x104 >2x104 >5x104 Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 0.5mm/AgSnO2 400V 16A/250V 2000W 1000W 1000W 500W 700W; ION ≤ 70A/10ms 650W 4V/10mA 0.5 … 12min. >107 >105 >104 >105 Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 0.9…1.1xUn 100% 50ms / 50ms -5...+60°C 50mA 1A Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 0.9…1.1xUn 100% 50ms / 50ms -20...+50°C 150mA 330mA 20mA Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 Contacts E F G X Contact spacing / material Isolation voltage contact/contact Switching capacity Incandescent lamp load Fluorescent lamp load, lead-lag circuit Fluorescent lamp load, inductive or capacitive Fluorescent lamp load, parallel compensated Electronic ballast load Inductive load, cos ϕ = 0.6 at 230V DC switching capacity Minimum contact load Time range Mechanical service life(1) Electrical service life, cos = 1(1) Electrical service life, cos ϕ = 0.6(1) Electrical service life, 1000W incandescent lamp(1) Screws Terminal capacity: min max Control system Control voltage range Relative duty at rated voltage Minimum duration of command impulse Operating temperature range Power consumption Maximum load of illuminated push-buttons Inrush current at 230V (first µs) Continuous excitation current Screws Terminal capacity: min max (1) Guaranteed at a switching frequency of 1000/h D.14 Redline Pulsar TS - Staircase switches Delay Nominal current Contact combination Operating voltage Number of modules Cat. No. Ref. No. Pack. Electromechanical 0.5...12 min. 16A/250V 1NO 230V 1 PLT S EM 666510 12 Electronic Flasher 0.5...12 min. 16A/250V 1NO 230V 1 PLT S EF 666518 1 Pulsar TS A B C Selection knob of type PLT S EM D E F G Staircase function X Staircase function plus switch off warning Staircase function plus push-button continuous light Staircase function plus switch off warning and push-button continuous light Sign for continuous light Sign for push-button 230V Sign for glow lamp max. load 150mA Lamp connection D.15 Redline Time Relays Pulsar T Comfort functions Applications From the delayed lighting of driveways (to avoid unnecesary on/off switching), to after-circulation of a pump (to build in some hysteresis, again to avoid continuous on/off switching) to the post-present ventilation of a meeting-room. Features Function A Conditioning of incoming impulses to exact predictable output impulses. B Standard Devices with delay on (ON), delay off (OFF), combined on-off-delay (OO), astable (AS), positive edge single shot (PS) negative edge single shot (NS) and even with all the above combined in one multi-function (MF) device are available. User presettable prescaler and time. In the case of the multi-function relay, the function itself is also user selectable. All devices have an internal step-down voltage converter. Therefore an AC as well as a DC supply and a very wide range of supply-voltages can be used to operate those devices. The loss-proof safety terminals are equipped with Pozidriv screws and have IP20 protection degree. IEC 60669-2-3 C D E F G X Performance Electronic time relays with simple or multifunction Contacts Contact spacing / material Spacing between control and load circuit Isolation voltage contact/contact Isolation voltage contact/magnetic system Switching capacity Incandescent lamp load Fluorescent lamp load, lead-lag circuit Fluorescent lamp load, inductive or capacitive Fluorescent lamp load, parallel compensated Electronic ballast load Inductive load, cos ϕ = 0.6 at 230V DC switching capacity Minimum contact load Time range Mechanical service life (1) Electrical service life, cos ϕ = 1 (1) Electrical service life, cos ϕ = 0.6 (1) Electrical service life, 1000W incandescent lamp (1) Screws Terminal capacity: min max 0.5mm/AgSnO2 3mm 250V 250V 10A/250V 1000W 1000W 1000W 500W 700W; ION ≤ 70A/10 ms 650W 100W 4V/10mA 0.1s. ... 40h >107 >105 >104 >105 Pozidriv 1 1x0.5 mm2 1x12 mm2 or 2x6 mm2 Control system Control voltage range Relative duty at rated voltage Minimum duration of command impulse Operating temperature range Power consumption Maximum load of illuminated push-buttons Inrush current at 230V (first µs) Screws Terminal capacity: min max (1) Guaranteed at a switching frequency of 1000/h. D.16 12 ... 230VUC (=DC or AC 50/60Hz) 100% 50ms -20 ... +50°C 0.2 ... 2.5W NOT ALLOWED 6 ... 25mA for all voltage-range Pozidriv 1 1x0.5 mm2 1x12 mm2 or 2x6 mm2 Redline Pulsar T - Time relays Contact combination Operating voltage AC/DC Number of modules Cat. No. Ref. No. Pack. Delay On 10A/250V 1CO 12 ... 230V AC/DC 1 PLT ON 666622 12 Delay Off 10A/250V 1CO 12 ... 230V AC/DC 1 PLT OF 666621 12 Delay On/Off 10A/250V 1CO 12 ... 230V AC/DC 1 PLT OO 666627 12 Pulsar T Switching capacity A B Positive edge single shot 10A/250V 1CO 12 ... 230V AC/DC 1 PLT PS 666625 12 C D Negative edge single shot 10A/250V 1CO 12 ... 230V AC/DC 1 PLT NS 666624 12 E F Symmetrical flasher 10A/250V 1CO 12 ... 230V AC/DC 1 PLT AS 666620 12 G X Multifunction 10A/250V 1CO 12 ... 230V AC/DC 1 PLT MF 666623 12 D.17 Redline Analogue Time Switches Classic Comfort functions Features A Very easy programming by means of mechanical switches on a dial, but with restricted possibilities compared to the digital time switches. Both devices with 1 dial for programming of daily or weekly events, as well as devices with 2 dials for 2 channel daily events and combined daily and weekly events are available in 2 versions: quartz and net synchronised, with and without running reserve respectively. Manual override Off or On is possible at all times. All devices are sealable. Applications Function Pre-programmed switching of all kinds of electrical devices. Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work-environment , waterheating, etc.), to the pre-programmed switching of motors for pumps and fans and even to presence simulation. B Standards C VDE 0633, BS EN 60730-1, BS EN 60730-2-7 D Performance Plastic switches Metallic switches Net synchronised 1 module Net synchronised 3&6 modules Quartz synchronised 1 module Quartz synchronised 3&6 modules Net synchronised 3 modules Quartz synchronised Voltage free NO Not fix off Voltage free CO yes Voltage free NO Not fix off Voltage free CO yes Voltage free CO yes Voltage free CO yes 16A/250V 4A/250V 1000W 30min. Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 16A/250V 4A/250V 1350W 30min. 3h Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 16A/250V 4A/250V 1000W 30min. Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 16A/250V 4A/250V 1350W 30min. 3h Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 16A/250V 4A/250V 1350W 15min. 2h Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 16A/250V 2A/250V 1350W 15min. 2h Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 220 - 240V 50Hz 1VA -20...+55°C net synchronised yes Pozidriv 1 1x0.5mm2 1x6 or 2x2.5mm2 230V - 130VDC 230V 50/60Hz 220 - 240V 50Hz 230V - 130VDC 230V 50Hz 1VA 1VA 1VA 1VA 1VA 150h 300h 150h 70h 72h 70h -20...+55°C -20...+55°C -20...+55°C -20...+55°C -20...+55°C net synchronised ±2.5s./day at 20°C ±2.5s./day at 20°C ±2.5s./day at 20°C ±2.5s./day at 20°C yes yes yes yes yes Pozidriv 1 Pozidriv 1 Pozidriv 1 Pozidriv 1 Pozidriv 1 1x0.5mm2 1x0.5mm2 1x0.5mm2 1x0.5mm2 1x0.5mm2 1x6 or 2x2.5mm2 1x6 or 2x2.5mm2 1x6 or 2x2.5mm2 1x6 or 2x2.5mm2 1x6 or 2x2.5mm2 E Contacts F G X Contact Fix on, Fix off, Auto switch Rated switching capacity - Resistive load - Inductive load (cos ϕ = 0.6) - Incandescent lamps Shortest switching time day-program Shortest switching time week-program Screws Terminal capacity: min max Clockwork Operating voltage Own consumption at 230V Running reserve Battery charging time Operating temperature range Accuracy Sealable Screws Terminal capacity: min max More technical data Dimensions D.18 website pg D.39 Redline Classic - Analogue time switches NET SYNCHRONISED Week programmable Ref. No. Pack. No. of channels Nominal current Operating voltage 1x24x2 1x24x2 1x24x4 1NO 1CO 1CO 16A/250V 16A/250V 16A/250V 220 ... 240V 50Hz 220 ... 240V 50Hz 230V 50Hz - 30min. 30min. 15min. Not "OFF" yes yes 1 3 3 CLS S 11 D CLS S 31 D CLS S 31 D M 666111 666112 666113 1 1 1 1CO 1CO 16A/250V 16A/250V 220 ... 240V 50Hz 230V 50Hz - 3h 2h yes yes 3 3 CLS S 31 W 666114 CLS S 31 W M 666115 1 1 1NO 1CO 1CO 16A/250V 16A/250V 16A/250V 130VDC/ 230V 130VDC/ 230V 230V 50h 150h 300h 30min. 30min. 15min. Not "OFF" yes yes 1 3 3 CLS Q 11 D 666105 CLS Q 31 D 666104 CLS Q 31 D M 666106 1 1 1 1NO 7x24/3 7x24/2 Running Shortest Fix on/off No. of reserve switch time auto mod. Cat. No. Program Day programmable 1CO QUARTZ SYNCHRONISED Day programmable 1x24x2 1x24x2 1x24x4 Classic 1CO A 1NO Week programmable 7x24/3 7x24/3 1CO 1CO 1CO 16A/250V 16A/250V 130VDC/ 230V 230V 150h 300h 3h 2h yes yes 3 3 CLS Q 31 W 666109 CLS Q 31 W M 666110 1 1 B C D 1CO Day-Day programmable 1x24x2 + 1x24x2 2CO 16A/250V 130VDC/ 230V 150h 30/30min. yes 6 CLS Q 62 DD 666103 1 E F 1CO Day-Week programmable 1x24x2 + 7x24/3 2CO 16A/250V 130VDC/ 230V 150h 30min./3h yes 6 CLS Q 62 DW 666108 1 G X 1CO Accessories Surface mounting set No. of mod. Cat. No. 1 3 6 SMS 1 SMS 3 SMS 6 Ref. No. Pack. 666100 666101 666102 1 1 1 D.19 Redline Digital Time Switches Comfort functions Galax A Applications Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work environment , water heating, etc.), to the pre-programmed switching of motors for pumps and fans and even to random presence simulation. Function Pre-programmed switching of all kinds of electrical devices. B C D Features Very easy programming, with quasi unlimited possibilities compared to the analogue time switches. Devices with daily, weekly and yearly event programming possibilities are available in 1, 2 and 4 channel execution. All devices have a shortest switching time of one minute, some of them even one second, and are all internally quartz-synchronized, some of them with the possibility of being DCF77-synchronized. On some devices, the summer/winter time change is fully automatic. Devices with blockprogramming, holiday, random and impulse-function are available. Manual On or Off override is possible at all times and all devices are sealable. Standards E BS EN-60730-1, BS EN-60730-2-7, VDE 0633 Performance F G X Contacts Contact Rated switching capacity - Resistive load - Inductive load (cos ϕ = 0.6) - Incandescent lamps DC switching capacity Shortest switching time Screws Terminal capacity: min max Voltage-free changeover 16A/250V 2.5A/250V 1000W On request depending on type: 1min. or 1s. Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 Clockwork Operating voltage Own consumption at 230V Running reserve (at 20º C) Battery Operating temperature range Accuracy Sealable and unloosable cover Screws Terminal capacity: min max More technical data Dimensions D.20 220 - 240V 50-60Hz 5VA 1 module device: 150h / 2&3 modules: 3 years / 6 modules:6 years Lithium ( except 1 module device ) -25...+55°C ±2.5s./day at 20°C / 6 modules device: ±1s./day at 20ºC yes Pozidriv 1 1x0.5mm2 1x6mm2 or 2x2.5mm2 website pg D.39 Redline Galax - Digital time switches QUARTZ SYNCHRONISED Day programmable Program 1x24x60 No. of Switching channels capacity Operating voltage Running Shortest No. of proreserve switch time gram steps No. of mod. Cat. No. Ref. No. Pack. 1CO 16A/250V 220 ... 240V 3yr 1min. 12 2 GLX Q 21 D 12 666186 1 7x24x60 1CO 16A/250V 220 ... 240V 150h 1min. 42 1 GLX Q 11 W 42 666187 1 7x24x60 7x24x60 7x24x60 7x24x60 1CO 2CO 1CO 2CO 16A/250V 16A/250V 16A/250V 16A/250V 220 ... 240V 220 ... 240V 220 ... 240V 220 ... 240V 3yr 3yr 3yr 3yr 1min. 1min. 1s. 1s. 20 30 30 40 2 2 2 2 GLX Q 21 W 20 GLX Q 22 W 30 GLX Q 21 W 30 GLX Q 22 W 40 666188 666190 666189 666191 1 1 1 1 16A/250V 16A/250V 220 ... 240V 220 ... 240V 6yr 6yr 1s. 1s. 400 400 6 6 GLX Q 62 W 400 666192 GLX Q 64 W 400 666193 1 1 1CO Day/Week programmable 7x24x3600 7x24x3600 2CO 2CO 4CO Galax 1CO A 2CO Day/Week/Year programmable 365x24x3600 365x24x3600 4CO 2CO 4CO 16A/250V 16A/250V 220 ... 240V 220 ... 240V 6yr 6yr 1s. 1s. 400 400 6 6 GLX Q 62 Y 400 GLX Q 64 Y 400 666194 666195 1 1 B C 2CO 4CO D Accessories Battery for 2 and 6 module devices No. of mod. Cat. No. Ref. No. Pack. - GLX BAT 666180 E 1 F DCF-77 antenna for year programmable time switches - GLX DCF 666181 1 G X Programming tools Surface mounting set for 6 module devices - GLX PRG 666182 1 1 3 6 SMS 1 SMS 3 SMS 6 666100 666101 666102 1 1 1 D.21 Redline Time Switches Comfort functions 72 X 72 Classic and Galax Applications Going from the pre-programmed switching of lighting (car park, advertising signs, public roads, etc.) over pre-programmed switching of heating equipment (home and work environment , water heating, etc.), to the pre-programmed switching of motors for pumps and fans and even to random presence simulation. A Features B Very easy programing by means of mechanical switches or digital buttons. Devices with daily and weekly event programing possibilities. Analogue devices have a shortest switching time of 15 minutes and digital device has 1 minute. C Function D Pre-programmed switching of all kind of electrical devices. E Performance F G X D.22 Weekly timers Code Type Running reserve Shortest switch time Modules Nominal current Accuracy Number of channels Operating voltage Fix on/off auto Flush mounting Surface mounting DIN-rail mounting Number of memory position 666176 CLS 72Q41W 150 h 2h 4 16A/250V <2.5 s/day 1CO 220-240VAC/50-60Hz yes yes yes yes - 666175 CLS72S41W 2h 4 16A/250V <2.5 s/day 1CO 220-240VAC/50-60Hz yes yes yes yes - Daily timers 666178 CLS72Q41D 150 h 15 min 4 16A/250V <2.5 s/day 1CO 220-240VAC/50-60Hz yes yes yes yes - 666177 CLS72S41D 15 min 4 16A/250V <2.5 s/day 1CO 220-240VAC/50-60Hz yes yes yes yes - Daily/weekly timer 666179 GLX72Q41DW 150 h 15 min 4 16A/250V <2.5 s/day 1CO 220-240VAC/50-60Hz yes yes yes yes 20 Redline 72 X 72 Classic - Analogue time switches Program No. of channels Nominal current Operating voltage Running Shortest Fix on/off No. of mod. reserve switch time auto Day program 1x24 1x24 1CO 1CO 16A/250V 16A/250V 220...240 VAC 220...240 VAC 150 h 15 min 15 min yes yes 4 4 CLS72S41D CLS72Q41D 666177 666178 1 1 Week program 7x24 7x24 1CO 1CO 16A/250V 16A/250V 220...240 VAC 220...240 VAC 150 h 2h 2h yes yes 4 4 CLS72S41W CLS72Q41W 666175 666176 1 1 Cat. No. Ref. No. Pack. Day-Week program Program No. of channels Nominal current Operating voltage 1x24/7x24 1CO 16A/250 V 220 240VAC Running Shortest Fix on/off No. of reserve switch time auto mod. 150 h 72 x 72 Classic & Galax A 72 X 72 Galax - Digital time switches 1 min yes 4 Cat. No. Ref. No. Pack. GLX72Q41DW 666179 1 B C D E F G X D.23 Redline Light Sensitive Switches Galax LSS Comfort functions Applications A Control of lighting in shop windows, offices, car parking areas, controlling street lights, advertising signs, sun blinds, shutters, or even lighting in a home to simulate the presence of people. Features User presettable switch light intensity, intensity range and hysteresis (to avoid on/off a stable behavior). Reaction time is also user presettable. 1 channel, 2 channel and 1 channel with incorporated digital time switch with week-cycle, all with separate photocell are available besides a 1 channel all-in-one device. Standards VDE 0632, VDE 0633, BS EN 60669-1 Function B Electronic switch controlled by the intensity of the ambient light , detected by a separate or integrated photocell (depending on the model). When the light intensity drops below the threshold setting, the switch changes its state to the on position. An increasing ambient light intensity eventually will switch off the device again. C Performance D 1 channel 2 channel 1 channel + digital time switch 1 channel wall mounting 1 Voltage-free contact NO Voltage-free change over Voltage-free change over 1 Voltage-free contact NO Contacts E F G Contact Switching capacity - Resistive load - Inductive load (cos ϕ = 0.6) - Incandescent lamps Switching capacity Shortest switching time Screws Terminal capacity: min max 16A/250V 8A/250V 2000W 10A/250V 16A/250V 8A/250V 8A/250V 2000W 2000W 800mA at 24V, 300mA at 60V; 150mA at 220V 1 min. Pozidriv 1 Pozidriv 1 Pozidriv 1 1x0.5 mm2 1x0.5 mm2 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 1x6 mm2 or 2x2.5 mm2 1x6 mm2 or 2x2.5 mm2 10A/250V 2A/250V 1200W Not allowed Slot head 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 Light sensitive operating part X 2 ... 500 lux Light intensity switching range Switching hysteresis On/Off switching delay Light sensitive sensor wire-length Light sensitive sensor protection degree Operating voltage Own consumption at 230V Running reserve Battery Operating temperature range Accuracy Sealable Screws Terminal capacity: min max More technical data Dimensions D.24 website pg D.39 100 s. On 100 s. Off max 100m IP65 220/240V 50/60Hz 5VA -20 ... +55°C yes Pozidriv 1 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 2 ... 500 lux 2 ... 500 lux 30% above On-switching point Use presettable from Use presettable from 0 to 100 s. 0 to 100 s. max 100 m max 100 m. IP65 IP65 230V 50/60Hz 230V 50/60Hz 2.5VA 2.5VA 3 years at 20°C Lithium -20 ... +55°C -10 ... +55°C ±2.5 s./day at 20°C yes yes Pozidriv 1 Pozidriv 1 1x0.5 mm2 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 1x6 mm2 or 2x2.5 mm2 2 ... 2000 lux 50 s. On 50 s. Off IP54 (complete device) 220/240V 50/60Hz 6VA -35 ... +60°C Slot head 1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 Redline Galax LSS - Light sensitive switches DIN rail mounting, separate photocell included No. of channels Nominal current Operating voltage No. of modules Cat. No. Ref. No. Pack. 2 ... 500 lux 1NO 16A/250V 230V 1 LSS 11 666361 1 2 ... 500 lux 2CO 16A/250V 230V 3 LSS 32 666362 1 2 ... 2000 lux 1NO 16A/250V 230V - LSS W 666364 1 Galax LSS Wall mounting, photocell incorporated Program A GALAX – Light sensitive switches with digital clock Program Number of Nominal OperatingRunning Shortest No. of channels current voltage reserve switch time program steps DIN rail mounting, separate photocell included with digital clock 2 ... 500 lux & 7x24x60 1CO 16A/250V 230V 3yr 1 min. No. of Cat. No. Ref. No. Pack. mod. 30 3 LSS 31 666363 1 B C D E F Accessories No. of modules Cat. No. Ref. No. Pack. Photocell (spare part) - LSS LDR 666358 1 Tinted cover - - 601795 1 Surface mounting set 1 3 SMS 1 SMS 3 666100 666101 1 1 G X D.25 Redline Transformers Comfort functions Series T A B C Function Applications Reducing the voltage to a very low (safety) voltage used mainly as control-voltage in order to reduce the risk of electrocution due to environmental circumstances (I.e. high degree of humidity like outdoors, in a swimming pool complex, etc.). Features Approvals (1) Safety transformers have short-circuit protection and continuous nominal power. Bell transformers are recommended for intermittent use at the nominal power declared (50% for continuous use). Devices with integrated on/off switch or with integrated buzzer are available. Complete noiseless operation. Full power available at all secondary voltages. The safety terminals are equipped with captive Pozidriv screws and have IP20 protection degree. D E F G X Standards (1) Depending on the type IEC 61558-1-2-6: Safety transformer IEC 61558-1-2-8: Bell transformer Performance Nominal primary voltage and frequency Secondary voltage at nominal primary voltage Maximum secondary voltage at zero load Minimum secondary voltage at nominal load Maximum load Short-circuit protection Operating temperature Isolation voltage Protection degree Screw Terminal capacity: min max More technical data Dimensions D.26 Going from supplying power to a bell circuit , to supplying power to the control circuit of impulse switches, relays or contactors for the control of lighting, heating, etc. website pg D.41 Bell transformer Safety transformer 230V 50Hz / 240V 60Hz 8 or 12V 1.5xUn sec. 0.85xUn sec. Nominal power PTC -20…+40°C 4kV IP 20 Pozidriv 1 1x1mm2 1x16mm2 or 2x6mm2 230V 50Hz / 240V 60Hz 12 or 24V 1.05xUn sec. 1xUn sec. Nominal power PTC -20…+40°C 4kV IP 20 Pozidriv 1 1x1mm2 1x16mm2 or 2x6mm2 Redline Series T - Transformers Output power Secondary voltages Primary voltage Number of modules 5VA 10VA 15VA 8/12V 8/12V 8/12V 220..240V 220..240V 220..240V 8VA 16VA 30VA 12/24V 12/24V 12/24V Bell transformer Integrated on-off switch 8VA Safety transformer 15VA Bell transformer Cat. No. Ref. No. Pack. 2 2 2 TR B 5 TR B 10 TR B 15 666638 666636 666637 1 1 1 220..240V 220..240V 220..240V 2 2 2 TR B 8 TR B 16 TR B 30 666650 666651 666652 1 1 1 8/12V 220..240V 2 TR B 8S 666640 1 12/24V 220..240V 3 TR S 15 666641 1 5VA, 10VA, 15VA 8VA, 16VA, 30VA Series T A B 25VA 40VA 12/24V 12/24V 220..240V 220..240V 4 4 TR S 25 TR S 40 666642 666643 1 1 C D 63VA 12/24V 220..240V 6 TR S 63 666644 20 E F Buzzers Buzzer Buzzer 220..240V 12V 1 1 BU 230 BU 12 666629 666630 12 12 G X Bells Bell Bell 220..240V 12V 1 1 BE 230 BE 12 666632 666633 12 12 D.27 Redline Measurement Instruments Series MT Comfort functions Applications A B C Measurement of all possible electrical values from simple measurement as voltage, current, frequency over more complex such as power and energy, to all-in-one measurement with the netanalysing devices. To avoid downtime due to abnormal situations, i.e. power-supply voltage too high, absorbed power too high, etc., leading to malfunctionning and even breakdown of the machinery, the measurement and monitoring of the electrical values like voltage, current, power, energy etc. is an absolute must and even an indespensable asset when it comes to preventive maintenance. Function Features Measurement , visualisation and logging of voltage, current , frequency, hours of operation, power, energy, cos ϕ , etc. Standards EN 61010-1, BS EN 60051-1-2 D E Performance F Readout G X Scale selection Own consumption current meters Own consumption other meters Operating temperature range Test voltage Class of precision (accuracy) Overload current coils - 1 second - Continuous Overload voltage coils - 0.5 second - Continuous Vibration resistance D.28 Analogue instruments Polycarbonate+carbon needle Digital instruments 3digit 7segment LED Net analyser LCD display Interchangeable scaleplate 0.3VA 1.5VA -10 ... +55ºC 2000V at 50Hz during 1 minute 1.5 (0.5 for frequency meter) Dip-switches Dip-switches 0.5VA 1.5VA -10 ... +55ºC 2000V at 50Hz during 1 minute 0.5% ±1 digit referred to full scale -10 ... +55ºC 2000V at 50Hz during 1 minute 0.5% ±1 digit referred to full scale 10xIn 2xIn 10xIn 2xIn 10xIn 2xIn 2xUn 2xUn 2xUn 1.2xUn 1.2xUn 1.2xUn 0.35 mm at 10/55Hz on 3 axes, 0.35 mm at 10/55Hz on 3 axes, 0.35 mm at 10/55Hz on 3 axes, duration of 6 hours duration of 6 hours duration of 6 hours 50g 50g 50g IP40 IP40 IP40 Pozidriv 1 Pozidriv 1 Pozidriv 1 1x1 mm2 1x1 mm2 1x1 mm2 1x16 mm2 or 2x6 mm2 1x16 mm2 or 2x6 mm2 1x16 mm2 or 2x6 mm2 Shock resistance Protection degree Screws Terminal capacity: min max More technical data Dimensions AC measurement devices with analogue as well as with digital technology and readout are available. The simple devices (one measurement only i.e. voltage, current, frequency) are only available in single phase, while the complex devices (more than one measurement i.e. power, energy, netanalyser) are also available in 3-phase execution. High currents can be measured through the intermediate use of a current transformer (for the analogue amp-meter combined with an interchangeable scale-plate). All devices have very good precision and have also a very low self-consumption to limit as much as possible the measurement error. Using one monophase-volt or amp-meter in a 3-phase system is possible by using the appropriate selector switch. The energy meters as well as the netanalysers are true RMS measuring devices. Monitoring and logging all electrical values on to a PC is possible by using the MT PRG software. website pg D.41 Redline Series MT - Analogue measurement instruments Accuracy Number of phases Number of modules Cat. No. Ref. No. Pack. Volt meter 300V 500V 1.5 1.5 1 1 3 3 MT AV 300 MT AV 500 666417 666418 1 1 Ammeter 5A 10A 15A 20A 25A 30A 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1 1 1 1 1 1 1 3 3 3 3 3 3 3 MT AA MT AA 5 MT AA 10 MT AA 15 MT AA 20 MT AA 25 MT AA 30 666414 666413 666408 666409 666410 666411 666412 1 1 1 1 1 1 1 Series MT Scale A B C Frequency meter 45 ... 65Hz 0.5 1 3 MT AF 666415 1 D E F G Hour counter 230V/50Hz 110V/50Hz 24V/50Hz - 1 1 1 2 2 2 MT AH MT AH 110 MT AH 24 666416 666431 666432 1 1 1 X D.29 Redline Series MT - Digital measurement instruments Volt meter Scale Accuracy Number of phases Number of modules Cat. No. Ref. No. Pack. 600V 500V 0.5 ± 1 dig 0.5 ± 1 dig 1 1 3 2 MT DV 600 MT DV 600 2M 666427 666670 1 1 5A 25A 0.5 ± 1 dig 0.5 ± 1 dig 1 1 3 3 MT DA 5 MT DA 25 666420 666419 1 1 5A 25A 0.5 ± 1 dig 0.5 ± 1 dig 1 1 2 2 MT DA 5 2M MT DA 25 2M 666671 666672 1 1 5A 0.5 ± 1 dig 1 2 MT DA DV 52M 666674 1 40 ... 80Hz 0.5 ± 1 dig 1 3 MT DF 666424 1 40 ... 80Hz 0.5 ± 1 dig 1 2 MT DF 2M 666673 1 9.999kW 999.9kW 1.5 1.5 1 1 3 3 MT DW 110 MT DW 11000 666428 666429 1 1 999.9kW 1.5 3 6 MT DW 31000 666430 1 30A 30A 1.5 1.5 1 1 3 3 MT DE 1 MT DE 1I 666421 666422 1 1 30A 32A 1.5 1.5 1 1 1 2 MT DE 1 1M MT DE 1I 32A 666675 666434 1 1 5A 1.5 3+N 6 MT DE 3I(1) 666423 1 5A 1.5 3 6 MT DE 3I O 666676 1 5A 5A 5A 1 1 1 1 3(+N) 3(+N) 8 8 6 MT DN 1 MT DN 3 MT DN 3L 666425 666426 666451 1 1 1(2) 666436 1 Comfort functions Ammeter Ammeter and Voltmeter Frequency meter A Watt meter B C D Energy meter E F G Net analyser X V Digital multimeter A 5A (x/5A) V A Var W 1.5 W (1) Only for net 3P+N (2) Oscilloscope function D.30 Hz VA VA 3 Var Hz cosϕ h1...h15% 6 kWh cosϕ kwh 4 tarifs kwhr 4 tarifs MODBUS MT DN 3R Redline Series MT - Current transformer Accuracy Cat. No. Ref. No. Pack. 40/5A 50/5A 60/5A 80/5A 3 3 3 3 MT CT 40 MT CT 50 MT CT 60 MT CT 80 666381 666383 666385 666387 1 1 1 1 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 1 1 1 0.5 0.5 0.5 MT CT 100 MT CT 150 MT CT 200 MT CT 250 MT CT 300 MT CT 400 666375 666377 666378 666379 666380 666382 1 1 1 1 1 1 500/5A 600/5A 0.5 0.5 MT CT 500 MT CT 600 666384 666386 1 1 800/5A 1000/5A 0.5 0.5 MT CT 800 MT CT 1000 666388 666376 1 1 1200/5A 1500/5A 2000/5A 0.5 0.5 0.5 MT CT 1200 MT CT 1500 MT CT 2000 666677 666678 666679 1 1 1 40/5A 50/5A 60/5A 80/5A 100/5A 150/5A 200/5A 250/5A 300/5A 400/5A 500/5A 600/5A 800/5A 1000/5A - MT SP 40 MT SP 50 MT SP 60 MT SP 80 MT SP 100 MT SP 150 MT SP 200 MT SP 250 MT SP 300 MT SP 400 MT SP 500 MT SP 600 MT SP 800 MT SP 1000 666395 666397 666399 666401 666389 666391 666392 666393 666394 666396 666398 666400 666402 666390 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Accessories RS485 to RS232 signal converter Series MT Interchangeable Ammeter scaleplates Scale A B C D Number of phases Number of modules Cat. No. Ref. No. Pack. - 2 MT RSC 666404 1 E F G Selector switch Amperage Voltage 3 3 3 3 MT S 4 MT S 7 666405 666406 1 1 X D.31 Redline Priority Relays Control and sequence phase relays Series PR Comfort functions Applications A B C Function Priority relays offer the possibility to limit the energy consumption in installations with a defined maximum power. This limitation is getting measuring the installation total current continuously and in the case consumption would be higher then fixed value, priority relay would disconnect the non-priority load. D In some installations the maximum power is limited by the contracted power with the electricity company. If this contracted power is surpassed, the main MCB of the installation opens. Priority relays are used in order to avoid the opening of the main MCB. A similar case, for exemple, would be an installation where new loads would be added without changing the installation (cable sizes, MCB’s...). In this case a priority relay will be installed before the non priority load that would be disconnected when the contracted or limited power is surpassed. Priority... disconnected. The priority relay will realise that the installation total load will come back to be lower than its..., the non priority load will come back to be connected. Characteristics Priority relay can work in nets with nominal power of 6 kW if we make a direct connection or higher if we use a current transformer to connect the priority relay to the net . In each case priority relay could be able to disconnect loads with a nominal power from 0 to 6kW or from 0% to 100% when current transformer is used. Standard/Marking IEC 61095 E Performance F Priority Relay Series PR 230V Nominal Voltage Un G X Maximum nominal current Nominal current Compact capacity Contact type Work temperature Work area Fixed delay time Isolation tension (contact-coil) Isolation class IP Electrical endurance Mechanical endurance Maximum changeover frequency Dimensions D.32 32A direct, 5A with current transformer 2...32A Pozidriv 1/2x2.5mm2 or 1x6mm2 NC or NO -20...+55°C 0 to 7 kW 0.5sc 2.5 kV II IP20 100,000 ops. 1,000,000 ops. 750 ops./h pg D.44 Redline Series PR - Priority relay Output number Module number Contact Cat. No. Ref. No. Pack. 1 1 2 2 1NO 1NC PRI 10 PRI 01 666445 666446 1 1 1 NO 1 NC Direct insertion C-T / 5A insertion Series PR A B C D Controls and sequence phase relays Functions number Module number Contact Cat. No. Ref. No. Pack. 4 2 3 3 1CO 1CO MTAP 3N MTAP 3N2F 666433 666690 1 1 E F G Functions Phases sequence Phases presence Neutral presence Min. voltage control Phases sequence Phases presence Min. voltage value range Ref. No. 70-100% 666433 - 666690 X D.33 Redline Surge Arresters Comfort functions SurgeGuard A B C Applications SurgeGuard surge arresters cover the protection of home appliances (TV, HiFi, VCR, laundry-machine, dishwasher, ...), commercial building equipment (computer and data communication network, intrusion and fire alarm system, access-control and building automation system), industrial equipment (PLC, instrumentation, medical apparatus, monitoring devices) and even the protection of entire off-shore drilling platforms. Function Protection of an electrical installation and all electrical and electronic devices connected to this installation against destructive overvoltage surges. Such voltage surges can be generated by lightning induced currents, by network-polluting devices such as motors, frequency-converters, dimmers etc. and by power supplier network switching operations. D Features Single and multi-pole devices (for TNC and IT respectively TNS and TT energy supplier networks); class 1 high energy deviation (10/350) and class 2 medium energy deviation (3/20) devices available; high current combined with low protection voltage; plug-in and monoblock devices both with and without voltage free signalling contact. In addition, all MOV-based devices have a built-in thermal fuse, to isolate the device from the rest of the installation in case of short-circuit or thermal runaway. A special low energy surge-suppression device (Sine Wave Tracking) is also part of this range of devices. Standards E NF C61-740, IEC 61643-1 F Performance G X Class 1 Single pole monoblock Class 2 Single pole plug-in Class 2 Multi pole monoblock Energy impulse wave Technology Response time Thermal fuse Thermal fuse healty indication Nominal voltage Frequency Protection mode 10/350 µs Closed spark-gap <100ns no 230V 50/60Hz L-PE and/or N-PE Useable in network Operating temperature Screws Terminal capacity: min max IT, TN-C, TN-S, TT -30…+75°C Pozidriv 3 1x2.5mm2 1x50mm2 8x20 MOV <5ns yes Mechanical flag 230V or 400V 50/60Hz Single mode: L-to-PE, N-to-PE IT, TN-C, TN-S, TT -30…+75°C Pozidriv 3 1x2.5mm2 1x50mm2 8x20 MOV <5ns yes LED 230V or 400V 50/60Hz 3- or 7-mode: L-to-PE, L-to-N and N-to-PE TN-S, TT -30…+75°C Pozidriv 3 1x2.5mm2 1x50mm2 More technical data Dimensions D.34 website pg D.46 Redline Surgeguard - Surge arresters CLASS 1 Single-Multi pole monoblock IIMP IN Up Up (L-N) Un 50kA 100kA 100kA - 4kV 4kV 4kV - - No. of Auxiliary Number of phases contact modules 1 3 1 - 2 4 2 Cat. No. Ref. No. Pack. VBAB1 VBAB3 VBANPE 560174 560186 544331* Cat. No. Ref. No. Pack. 1 1 1 * N-PE lighting current arresters CLASS 2 Replacement module (plug only) IN Up (L-PE) Up (L-N) Un No. of Auxiliary Number of phases contact modules 20kA 20kA 5kA 5kA 960V 1580V - 230V 400V 1 1 - 1 1 SG SP 2 20 2 SG SP 2 20 4 666545 666546 1 1 45kA 45kA 45kA 45kA 10kA 10kA 10kA 10kA 1000V 1000V 1490V 1450V - 230V 230V 400V 400V 1 1 1 1 1CO 1CO 1 1 1 1 SG SP 2 45 2 SG SP 2 45 2 C SG SP 2 45 4 SG SP 2 45 4 C 666547 666537 666548 666539 1 1 1 1 65kA 65kA 65kA 65kA 20kA 20kA 20kA 20kA 1200V 1200V 1950V 1950V - 230V 230V 400V 400V 1 1 1 1 1CO 1CO 1 1 1 1 SG SP 2 65 2 SG SP 2 65 2 C SG SP 2 65 4 SG SP 2 65 4 C 666549 666542 666551 666544 1 1 1 1 40kA 20kA 1500V - 230V 1 1CO 1 SG SP NGND PI 666552* 1 20kA 20kA 5kA 5kA 960kA 1580kA - 230V 400V 1 1 - 1 1 SG SP 2 20 2 P SG SP 2 20 4 P 666534 666535 1 1 45kA 45kA 10kA 10kA 1000kA 2100kA - 230V 400V 1 1 - 1 1 SG SP 2 45 2 P SG SP 2 45 4 P 666536 666538 1 1 65kA 65kA 20kA 20kA 1200kA 1950kA - 230V 400V 1 1 - 1 1 SG SP 2 65 2 P SG SP 2 65 4 P 666541 666543 1 1 40kA 20kA 1500kA - 230V 1 - 1 SG SP 2 40 2 NPE P 666553* 1 990V 990V 230V 230V 1+N 1+N - 2 2 SG MM 2 20 2 SG MM 2 45 2 666525 666527 1 1 Surgeguard Single pole plug-in Plug and Base IMAX A B C * N-PE lighting current arresters Multi pole monoblock 20kA 45kA 5kA 10kA 960V 1000V D E 20kA 45kA 45kA 80kA 5kA 10kA 10kA 20kA 960V 1000V 1000V 1200V 990V 990V 990V 990V 400V 400V 400V 400V 3+N 3+N 3+N 3+N 1CO 1CO 5 5 5 5 SG MM 2 20 4 SG MM 2 45 4 C SG MM 2 45 4 SG MM 2 80 4 C 666526 666530 666529 666533 1 1 1 1 F G X Accessories Decoupling coil Sine wave tracker In Number of phases Number of modules Cat. No. Ref. No. Pack. 35A 40A 63A 1 1 1 2 2 4 VED35 SG C 40 VED63 545879 666532 545857 1 1 1 - 1 1 SG SWT 666524 1 D.35 Redline Comfort functions Mains disconnect switches - Aster Switches - Aster A B C D Rotary switches - Aster Switches with signal lamp - Aster Push-buttons - Aster Indication lamp - Aster E F G X D.36 Redline Socket-outlet - Series MSC Dimensional drawings Contactors - Contax A B C Contactors Day and Night - Contax D E F G Contactors - Auxiliary contact Contactors - Spacer X D.37 Redline Comfort functions Relays - Contax R Relays - Auxiliary contact Impulse switches 1P - Pulsar S Impulse switches 2P - Pulsar S Electromechanical step-by-step - Pulsar S A B C D E F G X Impulse switches - Add-on module for electromechanical switches left mounting D.38 right mounting Redline Impulse switches - Spacer Staircase switches/Time relays - Pulsar T/TS Dimensional drawings Analogue time switches 1 module - Classic A B C Analogue time switches 3 & 6 modules - Classic D E F G Digital time switches 1 module - Galax X D.39 Redline Comfort functions Digital time switches 2 & 6 modules - Galax Light sensitive switch 1 module - Galax LSS Light sensitive switches 3 mod. - Galax LSS A B C D Light sensitive switch with digital clock - Galax LSS E F G X D.40 Light sensitive switch photocell incorporated Light sensitive switches - Photocell Redline Bell transformers - Series T Dimensional drawings Safety transformers - Series T A B C Buzzers and bells - 1 module Buzzers and bells - 2 modules D E F G Analogue measurement instruments - Series MT X D.41 Redline Comfort functions Digital measurement instruments - Series MT Energy meter - Series MT A B C D Network analyser - Series MT E F G X D.42 Signal converter - Series MT Selector switch - Series MT Redline Current transformer - Series MT 100 up to 400A 500 and 600A 800 and 1000A Dimensional drawings 40 up to 80A A B C D E F G X D.43 Redline Surge arresters - SurgeGuard Comfort functions Class 1 Surge arresters - SurgeGuard Class 2 - Single pole plug-in Surge arresters - SurgeGuard Class 2 - Multipole monobloc A B C D Decoupling coil - SurgeGuard E F G X D.44 Priority relay - Series PR Sine wave tracker - SurgeGuard 39231 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection (former GE Power Controls), a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide GE Consumer & Industrial Power Protection Redline ED.04 Modular DIN-rail devices and residential enclosures Just feel protected www.gepowercontrols.com www.ge.com/eu/powerprotection Redline - Modulair DIN-rail devices ED.04 GE imagination at work GE imagination at work GE POWER CONTROLS International Sales Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 90 E-mail: gepcbel@gepc.ge.com GE imagination at work GE imagination at work GE imagination at work GE imagination at work 680803 Ref. R/2260/E/X 15.0 Ed. 11/06 © Copyright GE Power Controls 2006