electric heating products

advertisement
electric
heating products
explosion-proof unit
heater
wall heater
ceiling heater
explosion-proof convector
washdown/corrosion
resistant unit heater
industrial unit heater
unit heater
convector heater
cabinet heater
baseboard heater
wall heater
radiant panel
commercial & industrial
For Limited Warranty Information contact:
HEATREX
425 HANLEY INDUSTRIAL COURT
ST. LOUIS, MO 63144
314-333-5500
www.heatrex.com
90-1000-80-1
5M0610
electric heating and controls
INTRODUCTION
HEATREX offers commercial and industrial electric heating
and control systems that set the industry standard for excellence. The company’s heating solutions reflect more than 80
years of innovation, product quality and efficient service.
This catalog features HEATREX’s complete
Space Heating line. Our products include
Explosion-proof an explosion-proof convector; the Washdown/Corrosion Resistant Unit
Heater; and several types of standard unit
heaters.
HEATREX’s line of Comfort Heating
Products cover a wide range of commercial
and industrial applications. Whether the
requirement is for architectural wall heaters,
cabinet unit heaters, convector heaters or
ceiling heaters, HEATREX has a product to
match the application.
HEATREX’s quality is matched only by its
customer service and support. With its quick-ship delivery
program, HEATREX provides the products you need.
Color Selection Chart
Standard Colors 900 Series
White
(W)
Standard Color 240 Series
Almond
(A)
Special Colors 900 Series
Camel
Optional Colors 240 Series
Metallic Silver
(AE)
Beige-Grey
(BG)
Grey
Yellow
Metallic Charcoal
(CM)
Bronze
(BZ)
Red
White
Textured Black
(NR)
Aluminum
(AL)
Blue
Textured Beige
Refer to catalog listings for standard and special color availability. Use color codes in
parentheses when specifying and ordering. Custom colors are also available on 900
Series. Special and Optional Colors subject to setup charges. Colors represented are
approximate.
Table of Contents
Advantages/Applications
2
Use of Electric Heaters in
Hazardous Locations
3-5
Comparison Chart
6-7
Explosion-proof Unit Heaters
233 Series Explosion-proof Unit Heaters
922 Series Cabinet Unit Heater
56-59
936/937 Series Commercial Ceiling
Heater
60-63
931 Series Commercial Ceiling Heater
64-65
8-14
236 Series Compact Explosion-proof Unit
Heaters
15-17
254 Series Convector
18-21
928 Series Toe-Space Heater
66
939 Series Floor Insert Heater
67
Baseboard and Convector Heaters
Comparison Chart
68
Fan Forced Heaters
Comparison Chart
22
234 Series Washdown/Corrosion
Resistant Unit Heaters
23-25
238 Series Industrial Unit Heater
26-28
240 Series Unit Heater
29-32
926 Series Unit Heater
33-35
924 Series Economical Unit Heater
928 Series Vertical Unit Heater
927 Series Portable Heater
902 Series Commercial Baseboard
Heater
69-71
904/906 Series Architectural Sill-Height
Convector
72-74
905/907 Series Industrial Sill-Height
Convector
75-77
908/909 Series Architectural Convector
78-80
914 Series Mini Draft Barrier Heater
82-84
916 Series High Watt Density Draft Barrier Heater
85-87
911/912 Series Architectural Cabinet
Convector
88-91
37
38-40
41
Wall, Ceiling and Floor Heaters
Comparison Chart
42-43
933 Series Architectural Wall Heater
44-46
932 Series Commercial Wall Heater
47-49
935 Series European Wall Heater
50
940 Series Hybrid Convection & ForcedAir Wall Heater
51
934 Series Wall Heater
52-53
930 Series Register Wall Heater
54-55
Radiant Panels
AS Series
92-95
Cove Heater
96-97
Thermostats
Limited Warranty
Color Section Chart
98-99
100
Inside Back Cover
1
Advantages/Applications
®
Experience
This catalog represents 80 years of experience in industrial
electric heating – our specialty since HEATREX was founded
in 1929. HEATREX has been manufacturing products for use
in hazardous locations for over 55 years.
Complete Product Line
HEATREX offers the industry’s most comprehensive line of
space heating equipment. Explosion-proof unit heaters are
available with ratings up to 30 kW and 600 volts. 234 Series
unit heaters provide heat in nonhazardous environments where moisture and corrosion
are present. Standard unit heaters include a heavy duty
industrial model, several commercial models, vertical,
cabinet and portable designs. A wide range of floor, wall
and ceiling heaters, including baseboard heaters and radiant
ceiling panels, are available to meet any application requirement. HEATREX also offers the widest selection of built-in
controls in the industry.
Quick Delivery
A wide selection of assembly stock designs with options are
available in two weeks. Most comfort heating products will
ship in two weeks.
Colors
American
Bureau of
Shipping
Many of HEATREX’s comfort heating products
are available in a choice of colors. Standard and
special colors are shown in the back of this catalog. Custom
colors, including bronze or clear anodizing and matches to
customer supplied paint samples, are also available on
select heaters.
Safety
HEATREX explosion-proof unit heaters are Factory Mutual
(FM) Approved and include redundant overtemperature
protection which exceeds agency requirements. The 233
Series unit heater has the industry’s lowest Ignition
Temperature Code rating, 320°F (160°C), and is also CSA
Approved.
HEATREX corrosion resistant heaters are available with
cULus Approvals. Explosion-proof and corrosion resistant
heater designs are available for marine and shipboard use
that are ABS Approved and meet U.S. Coast Guard requirements.
HEATREX commercial and industrial unit heaters are UL
and cUL Approved for non-hazardous, non-corrosive
environments. Comfort heating products are CSAus or CSA
Approved.
Hazardous and Corrosive Area Applications
• Aircraft Hangars/Service Areas
• Battery Storage Areas
• Chemical Plants
• Chemical Storage/Handling Areas
• Coal Mines/Preparation Plants
• Control Rooms
• Dry Cleaning Plants
• Dusty Areas Subject to Washdown
• Food Processing Plants
(Washdown Areas)
• Foundries
• Gasoline Fueling/Storage Areas
• Grain Elevators
• Hydrogen Atmospheres
• Marine/Shipboard and Landbase Facilities
• Natural Gas (Methane) Atmospheres
• Oil Refineries
• Offshore Drilling Rigs
• Paint Spraying/Storage Areas
• Parking Garages
• Petrochemical Plants
• Pipeline Pumping Stations
• Pulp and Paper Mills
• Sewage/Wastewater
Treatment Plants
• Solvent Recovery/
Storage Areas
• Utility Plants
Industrial and Commercial Applications
• Basements
• Classrooms
• Conference Rooms
• Entryways/Hallways
• Factories
• Lobbies
2
• Mechanical Rooms
• Offices
• Power Generating Stations
• Pump Houses
• Restrooms
• Service Stations/Garages
• Shipping and Receiving Areas
• Stairwells
• Storage Areas
• Vestibules
• Warehouses
• Workshops
Use of Electric Heaters
In Hazardous Locations
Introduction
Hazardous locations are those areas where a potential for
explosion and fire exists due to the presence of flammable
gases, vapors, pulverized dusts or ignitable fibers in the
atmosphere. Hazardous locations are created from the normal processing of volatile chemicals, gases, coal, grains, etc.,
or from the accidental failure of storage systems for these
materials.
Open flames are not permitted in these locations. The use
of electric heating equipment is permitted with two major
restrictions: 1) The surface temperature of the equipment
cannot exceed the ignition temperature of the hazardous
atmosphere and 2) all arc and spark producing devices must
be isolated from the atmosphere in an appropriate enclosure.
Both people and equipment in hazardous locations can be
heated safely and economically with electric heat. Electric
heating is typically much less expensive to install and maintain than comparable remote oil or gas fired heating systems.
National Electrical Code Classification
Articles 500 through 516 of the National Electrical Code deal
with the definition of hazardous areas and the use or design
of electrical equipment used in these locations. Electric
heating equipment for hazardous areas is specified based on
the NEC class, division, group and ignition temperature or
the alternate class and zone classification.
Class
in the atmosphere. Typical locations would include coal fired
power plants, coal preparation/coal handling facilities, coal
mines, grain elevators, flour and feed mills, packaging and
handling of pulverized sugar and processing and storage of
magnesium and aluminum powder.
Class III – This third classification is primarily a fire hazard where fibers or flyings suspended in the air create a
hazard. This would include small pieces of thread-like fiber,
sawdust, lint, etc. Typical applications would include textile
mills, woodworking plants, cotton gins, cotton seed mills
and flax producing plants.
Division
Class I, Class II and Class III areas are further defined in
terms of when the hazard occurs. Division 1 and Division 2
occurrences are summarized below.
Division 1 – If the hazard is expected to be present under
normal conditions, such as a production or processing facility, the occurrence is designated Division 1. The hazardous
atmosphere may be present continuously, intermittently,
periodically, or during normal repair or maintenance operations. Division 1 occurrences also include locations where
a breakdown in the operation of processing equipment
results in the release of hazardous vapors.
Division 2 – If the hazardous material is normally expected
to be contained within a closed area, system or container,
and would enter the ambient atmosphere only under an
abnormal failure, then it is referred to as a Division 2 occurrence.
Hazardous locations are divided into the three general classes of vapors/gases, dusts and fibers.
Class I – Locations where the potential for explosion and
fire exists due to the presence of flammable gases or vapors
in the air. Typical Class I locations include oil or natural gas
drilling rigs, petroleum refining or pumping facilities, petrochemical plants, wastewater/sewage treatment plants,
solvent extraction plants, paint spraying booths, locations
where open tanks or vats of combustible liquids are present
and storage areas for flammable materials.
Class II – Locations where the potential for explosion exists
because of finely pulverized flammable dusts suspended
3
Use of Electric Heaters
In Hazardous Locations
Group
The nature and explosive characteristics of the hazardous
material are defined by the NEC group to which it is assigned.
Class I – Hazardous vapors/gas locations include chemicals and
other materials that have been divided into four groups based
on their ignition temperature and explosive characteristics.
(Groups A, B, C and D)
Class II – Hazardous dust locations are divided into three
groups based on their ignition temperature and electrical conductivity of the suspended particles.
Group E – Atmospheres containing metal dust, such as aluminum or magnesium.
Group F – Atmospheres containing coal, charcoal or coke
dust.
Group G – Atmospheres with grain, flour, starch, combustible
plastics or chemical dust.
Class III – Locations have no group definitions.
Class I, Zone 1 – Locations in which ignitable concentrations of
flammable gases or vapors are likely to exist, may exist frequently or exist as a result of equipment breakdown or faulty operation. Applies to locations adjacent to a Class I, Zone 0 location.
Class I, Zone 2 – Locations in which ignitable concentrations of
flammable gases or vapors are not likely to occur under normal
operation, exist only for a short period or exist only as a result of
accidental failure, such as rupture or breakdown of the container
or system, abnormal operation of equipment, failure or abnormal operation of the ventilation equipment. Applies to locations
adjacent to a Class I, Zone 1 location.
Material Groups
Group IIC – Atmospheres containing acetylene or hydrogen.
Equivalent to a combination of Class I, Group A and Class I, Group
B as described in NEC Article 500.
Class and Zone Classifications
Group IIB – Atmospheres containing acetaldehyde. Equivalent
to Class I, Group C as described in NEC Article 500.
Ignition Temperature
Group IIA – Atmospheres containing acetone, ammonia, ethyl
alcohol, gasoline, methane or propane. Equivalent to Class I,
Group D as described in NEC Article 500.
All electrical equipment is designed not to exceed the ignition temperature of the hazardous atmosphere. The maximum surface temperature for electric heaters is defined by
the NEC.
Maximum Surface
Temperature of Heater
4
Class I, Zone 0 – Locations in which ignitable concentrations of
flammable gases or vapors are present continuously or for long
periods.
°F
°C
NEC
Ignition
Temperature
Code
842
450
T1
572
300
T2
536
280
T2A
500
260
T2B
446
230
T2C
419
215
T2D
392
200
T3
356
180
T3A
329
165
T3B
Use of Electric Heaters
In Hazardous Locations
Special Requirements for Electric Heating Equipment used in Hazardous Areas
Electric heating equipment can be economically designed and
safely used in hazardous areas if the following special requirements are observed.
1. The surface temperature of the electric heating equipment
cannot exceed the ignition temperature of the hazardous atmosphere. To insure that the proper heater has
been selected, it is essential that the correct NEC Ignition
Temperature Code be specified.
If the temperature code selected is too high, the electric heating
system may operate above the ignition point of the application,
creating a potentially hazardous condition.
CLASS I - HAZARDOUS GAS ATMOSPHERES
NEC
Material
°F
°C
A
Acetylene
581
305
T2
B
Acrolein (Inhibited)
428
220
T2D
Butadiene
Ethylene Oxide
Hydrogen
Propylene Oxide
Propyl Nitrate
788
804
932
840
347
420
429
500
449
175
Acetaldehyde
347
175
713
1128
928
842
1000
500
802
610
378
609
498
450
538
260
428
321
C
Allyl Alcohol
Carbon Monoxide
Cyclopropane
Ethylene
Hydrogen Cyanide
Hydrogen Sulfide
2-Nitropropane
Tetrahydrofuran
D
Code
867
463
465
651
Benzene
928
498
T1
Butane
550
287
T2A
1-Butanol (Butyl Alcohol)
2-Butanol
(Secondary Butyl Alcohol)
Ethane
Ethanol (Ethyl Alcohol)
Ethyl Acetate
Ethylene Dichloride
Gasoline (56-60 Octane)
Gasoline (100 Octane)
Heptanes
Hexanes
Isoprene
Isopropyl Ether
Methane (Natural Gas)
650
761
343
405
882
685
800
775
536
853
399
437
428
830
9001170
867
662
472
363
427
413
280
456
204
235
220
443
482632
454
350
759
404
Methanol (Methyl Alcohol)
3-Methyl-1-Butanol
(Isoamyl Alcohol)
Methyl Ethyl Ketone
The materials given are found in NFPA 497, 1991 and NFPA 325, 2001.
Ignition Temp.
Group
D
T3B
869
1204
Acetic Acid (Glacia)
Acetone
Ammonia, Anhydrous
3. All electrical supply connections must be made according
to the latest NEC and local code requirements for hazardous locations. This includes the requirement that conduit
entering the enclosures must be provided with seals at the
enclosure.
CLASS I - HAZARDOUS GAS ATMOSPHERES
Ignition Temp.
Group
2. All arc and spark-producing control devices must be isolated from the hazardous atmosphere. If it is not economically
feasible to locate the control devices in the non-hazardous
area, they must be housed in an enclosure that will withstand the pressure of a potential explosion from within the
enclosure.
T1
Material
NEC
°F
°C
Code
Methyl Isobutyl Ketone
840
448
T2
2-Methyl-1-Propanol
780
415
T2
(Isobutyl Alcohol)
Petroleum Naptha
Pyridine
Octanes
Pentanes
550
900
403
500
288
482
206
260
T2A
T1
T3
T2B
1-Pentanol (Amyl Alchohol)
650
343
T2
Propane
1-Propanol (Propyl Alchohol)
2-Propanol (Isopropyl Alcohol)
Propylene
Styrene
Toluene
Vinyl Acetate
Vinyl Chloride
842
775
750
851
914
896
756
882
450
412
399
455
490
480
402
472
T1
T2
T2
T1
T1
T1
T2
T1
Xylenes
867-
463-
T1
984
528
CLASS II - HAZARDOUS DUST ATMOSPHERES
Group
Material
E
Aluminum, A422 Flake
Calcium Silicide
Manganese
Magnesium, Grade B, Milled
F
Charcoal
Coal, Kentucky Bituminous
Coal, Pittsburgh Experimental
Pitch, Petroleum
G
Alkyl Ketone Dimer
Sizing Compound
Corn
Corn Starch, Modified
Polyurethane Foam,
Fire Retardant
Shellac
Soy Flour
Sugar, Powdered
Sulfur
Wheat
Wood Flour
Ignition Temp.
NEC
Code
°F
°C
608
1004
464
806
356
356
338
1166
320
320
540
240
430
180
180
170
630
160
T2
T1
T2C
T2
T3A
T3A
T3B
T1
T3C
482
392
734
250
200
390
T2C
T3
T2
752
374
698
428
428
500
400
190
370
220
220
260
T2
T3A
T2
T2D
T2D
T2B
5
H E A T E R S
Comparison Chart
EE XX PP LL OO SS II O
O N
N -- PP RR O
O O F
Only HEATREX offers a
selection of explosion-proof
heater constructions to meet
your specific application.
Features
Hazardous Location
NEC Classifications
Ignition Temperature Code
KW Range
Standard Built-in Overtemperature Protection
Other Standard Built-in Controls
233 Series
Our most popular and versatile construction
has a broad range of stock designs, special
options and the industry’s lowest Ignition
Temperature Code rating, 320°F (160°C).
233 Series
Class I, Divisions 1 and 2, Groups C and D
Class II, Divisions 1 and 2, Groups E, F, and G
Class 1, Zones 1 and 2, Groups IIB
T3C
320°F (160°C)
Up to 30 KW
Dual overtemperature protection with automatic and
manual reset thermal cutouts
Controlling contactor,
control circuit transformer
Standard Control Voltage
24V
Single Point Line Voltage Connection
for Incoming Power
Yes
Optional Built-in Controls
Thermostat
Yes
Disconnect Switch
Yes
Selector Switch
Yes
Manual Reset Cutout
Standard
“Heater On” Pilot Light
Yes
“Warning” Pilot Light
Yes
Control Circuit Transformer
Standard
Standard Construction
Heater Assembly
Liquid-to-air heat exchanger, steel tube with
aluminum fins, propylene glycol, immersion heater
Cabinet/Housing
Powder coated galvanized steel
NEMA 7, 9 Control Enclosure
Mounting Brackets
Cast aluminum
Wall, ceiling or pole mounting kits (optional)
Optional Constructions
Dirty Duty Corrosion Resistant
50 Hertz Motor
Choice of 316SS Construction or Heresite® coating
Yes
Agency Approvals
6
FM (Factory Mutual)
Yes
CSA (Canadian Standards Association)
Yes
ABS (American Bureau of Shipping)
No
Comparison Chart
254 Series
The industry’s
smallest and most
economical design
for Class I, Group
D applications up to
12 KW.
Small, compact design with
a wide range of optional
built-in controls.
236 Series
254 Series
Class I, Divisions 1 and 2, Group D
Class 1, Zones 1 and 2, Group IIA
Class I, Divisions 1 and 2, Groups B, C and D
Class II, Divisions 1 and 2, Groups E, F, and G
Class 1, Zones 1 and 2, Groups IIC
T3
392°F (200°C) (Varies with KW)
T3C
320°F (160°C) (Varies with classification)
Up to 9.5 KW
Primary automatic reset cutout
Controlling contactor
None
120V
Maximum 277V
Separate 120V motor line required
Yes
Yes
Yes
No
No
No
No
Yes
No
No
No
No
No
No
Yes
Stainless steel finned
tubular elements
Heater core enclosed in copper tube
with large aluminum fins
Stainless steel
Powder coated galvanized steel
Cast aluminum
Cast aluminum
Swivel mounting bracket (standard)
Wall mounting bracket (standard)
Yes
Wet locations (NEMA 3) iridite coated elements
No
N/A
Yes
Yes
Yes
Yes
Yes
Yes
H E A T E R S
Up to 12 KW
Primary and secondary automatic
reset cutouts with fan relay
E X P L O S I O N - P R O O F
236 Series
7
U N I T
H E A T E R
H E A T E R S
233 Series
E X P L O S I O N - P R O O F
HEATREX’s 233 Series explosion-proof unit heater is
designed with both safety and versatility in mind. Unique
features include:
• Industry’s Lowest Ignition Temperature Code Rating:
T3C, 320°F (160°C)
• Dual Overtemperature Protection: With both automatic
and manual reset overtemperature cutouts for
additional safety.
• Nontoxic Propylene Glycol Heat Transfer Fluid
Applications
•Aircraft Hangars/Service Areas
•Paint Storage Areas
•Chemical Storage/Handling Areas
•Petrochemical Plants
•Coal Preparation Plants
•Compressor Stations
•Sewage Pump Stations/
Treatment Plants
•Grain Elevators
•Spray Booths
•Oil Refineries and Rigs
Class I, Divisions 1 and 2, Groups C and D
Class II, Divisions 1 and 2, Groups E, F and G
Class I, Zones 1 and 2, Group IIB
Temperature Code T3C, 320°F (160°C)
• Low 70 PSIG Relief Valve Setting: This assures that in
an emergency, the initial escaping vapor temperature
remains below the 320°F (160°C) ignition temperature.
• Corrosion Resistant Options: HEATREX offers three constructions suitable for most applications.
Standard construction for use in dry non-corrosive areas
includes: welded steel heat exchanger; powder-coated
cabinet.
A 316 stainless steel construction suitable for Waste
Water Treatment Plants includes: 316 stainless steel
heat exchanger, headers and tubes with aluminum fins;
stainless steel cabinet; corrosion resistant hardware.
Third construction is suitable for use in Chemical Plants
where chlorides are present and includes: Heresite®
coated heat exchanger, cabinet, fan blade; corrosion
resistant hardware.
Standard Construction Features
8
Heat Exchanger – Efficient liquid-to-air design utilizes
an all welded steel headers and finned tube construction
with spiral wound aluminum fins. Industrial grade HEATREX
heating elements are immersed in a nontoxic, inhibited,
propylene glycol heat transfer fluid that provides freeze protection down to -49°F (-45°C). The heat exchanger is hydrostatically tested at 350 psig. A pressure relief valve provides
excess pressure protection and is set at 70 psig.
is rated for Class I, Groups C and D, Class II, Groups F and G.
The minimum operating temperature is -14°F (-25°C) and the
minimum storage temperature is -49°F (-45°C). Optional
motor ratings are described on page 9.
Fan Motor Assembly – Consists of an explosion-proof
motor fitted with an aluminum fan blade. The motor has
double-shielded, permanently lubricated ball bearings and
automatic reset line breaking thermal overload protection.
Motors furnished on standard units operate at line voltage
and are prewired to the control enclosure so separate field
wiring to the motor is not required. The standard motor
Controls – Factory mounted on the unit heater. Standard builtin controls include automatic and manual reset overtemperature cutouts, controlling magnetic contactor, and 24-volt
control circuit transformer housed in a NEMA 7, 9 cast aluminum enclosure.
Cabinet/Louvers – Industrial grade, corrosion resistant
construction fabricated from powder coated 14-gauge galvanized steel. The adjustable louvers have minimum opening
safety stops.
U N I T
H E A T E R
233 Series
E X P L O S I O N - P R O O F
Factory Built-in Options
Code
Option
Description
Availability
Code (2)
316 Stainless steel heat exchanger with aluminum fins, 316
stainless steel cabinet; aluminum fan blade; cast aluminum
NEMA 4X, 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor, which has
passed the ASTM B117 salt-spray test.
C
C2
Dirty Duty Corrosion-Resistant Construction
(Chemical Plants)
Heresite® coated heat exchanger, cabinet and fan blade; cast
aluminum NEMA 4X, 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor
which has passed the ASTM B117 salt-spray test.
C
D
Disconnect Switch
Factory installed on the unit heater above the control
enclosure. This is an inexpensive and positive way to meet
NEC/CEC requirements for a disconnecting means within sight
of the heater.
AS
E
Group E (Metal Dust)
Construction
Class II, Group E (Metal Dust) Construction Temperature Code
T3C, 320°F (160°C)
C
H
50 Hertz Motor
Optional motors for international requirements.
(See page 13 for KW availability)
C
K
“Warning” Pilot Light
Indicates when the thermal cutouts have tripped and the unit
heater needs servicing.
AS
L
“Heater On” Pilot Light
Indicates when the electric heating elements are energized.
AS
M
Manual Reset
Thermal Cutout with
Backup Contactor
A pilot duty manual reset thermal cutout with a backup
contactor is provided for independent secondary overtemperature protection. This option cannot be provided if option
Code S or V are also specified.
AS
S
Auto/Fan
Selector Switch
A two-position switch wired to the control circuit for auto (automatic heat) and fan only control. This selector switch cannot
be provided if option Code M or V are also specified.
AS
T
Adjustable Thermostat
Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50° to 90°F
(10° to 32°C) range.
AS
V
120 Volt Control Circuit
Fused secondary and
grounded
Can be provided when required for special external thermostat circuit. This option cannot be provided if option Code S or
M are also specified. Nor can both K and L be specified.
AS
H E A T E R S
C1
316 Stainless Steel
Corrosion-Resistant
Construction (Waste
Water Treatment Plants)
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
9
H E A T E R S
233 Series
U N I T
H E A T E R
Accessory Items
Heater Mounting Kits
5" (127 mm)
E X P L O S I O N - P R O O F
These are available for ceiling, wall and pole mounting configurations as described below. Specify type required and catalog
number at time of order entry.
6-1/8"
(159.76 mm)
MW
MH
2.5
(63.5)
5" (127 mm)
Ceiling Mounting Kit
MW
Wall Mounting Kit
Size
MH In. (mm)
MW In. (mm)
1
11.063 (281)
9 (228.6)
2
15.063 (382.6)
7 (177.8)
3
19.063 (484.2)
5 (127)
Pole Mounting Kit
Unit Heater Mounting Kits (One kit required per heater)
Standard Mounting Kits for use in most applications
Catalog
Number
Description
1022451
Ceiling Mounting Kit, for Frame Size 1, 2, 3
1022454
Wall Mounting Kit, for Frame Size 1, 2, 3
1022457
Pole Mounting Kit, for Frame Size 1, 2, 3
Availability
Code (2)
AS
Optional Mounting Kits for Option C1 or C2 heaters.
Catalog
Number
Description
1022451-S
Corrosion Resistant Ceiling Mounting Kit, for Frame Size 1, 2, 3
1022454-S
Corrosion Resistant Wall Mounting Kit, for Frame Size 1, 2, 3
1022457-S
Corrosion Resistant Pole Mounting Kit, for Frame Size 1, 2, 3
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
Remote Room Thermostat – Use catalog number 1007002. See page 98.
10
Availability
Code (2)
AS
U N I T
233 Series
H E A T E R
Frame Size
Size 1
Size 2
Size 3
‘X’ In. (mm)
21.75 (552.45)
21.75 (552.45)
20.875 (530.23)
‘Y’ In. (mm)
19.375 (492.125)
23.375 (593.725)
27.375 (695.325)
‘Z’ In. (mm)
16.063 (408)
20.188 (512.775)
24.188 (614.375)
Net Lbs. (kgs)
110 (49.89)
150 (68.03)
190 (86.18)
Shipping Lbs (kgs)
130 (58.96)
169 (76.65)
216 (97.97)
Overall
Heater
Dimensions
Weight
60 Hertz Heaters
KW Range
7.5 - 10
25
30
650
(1104)
850
(1444)
1800
(3058)
3110
(5283)
3850
(6541)
Air Throw Feet (m)
15 (4.5)
25 (7.6)
45 (13.7)
65 (19.8)
75 (22.8)
RPM
Motor/Fan
15
20
1725
HP
1/4
Fan Blade Dia. In. (mm)
1/2
12 (304.8)
16 (406.4)
20 (508)
50 Hertz Heaters
KW Range
Airflow
Characteristics
2.5 - 4.2
6.3 - 8.4
Air Volume CFM
(cubic meter/hr.)
550
(934)
700
(1189)
1500
(2549)
2600
(4417)
Air Throw Feet (m)
13 (4)
22 (7)
39 (12)
57 (17)
16 (406.4)
20 (508)
RPM
Motor/Fan
12.5
16.7
H E A T E R S
Airflow
Characteristics
3-5
Air Volume CFM
(cubic meter/hr.)
E X P L O S I O N - P R O O F
Dimensions, Airflows and Weights
21 - 25
1438
HP
1/4
Fan Blade Dia. In. (mm)
12 (304.8)
1/2
Y
X
Side View
6-3/4”
Z
Front View
11
H E A T E R S
233 Series
U N I T
Class I, Divisions 1 and 2, Groups C and D
Class II, Divisions 1 and 2, Groups F and G
Class I, Zones 1 and 2, Group IIB
Temperature Code T3C, 320°F (160°C)
E X P L O S I O N - P R O O F
Heater Listing 60 Hz
KW
3
5
7.5
10
15
20
25
30
H E A T E R
Volts
Phase
Total
Amps (1)
Frame
Size
Approximate Air
Temperature Rise
°F (°C)
Catalog
Number
208
1
17
1
15 (8)
HX-233-FA-0036C
240
1
15
1
15 (8)
HX-233-FA-0036J
208
3
10
1
15 (8)
HX-233-FA-0036D
240
3
9
1
15 (8)
HX-233-FA-0036K
480
3
5
1
15 (8)
HX-233-FA-0036U
600
3
4
1
15 (8)
HX-233-FA-0036Z
208
1
26
1
25 (13)
HX-233-FA-0056C
240
1
23
1
25 (13)
HX-233-FA-0056J
208
3
16
1
25 (13)
HX-233-FA-0056D
240
3
14
1
25 (13)
HX-233-FA-0056K
480
3
7
1
25 (13)
HX-233-FA-0056U
600
3
6
1
25 (13)
HX-233-FA-0056Z
208
1
38
1
28 (16)
HX-233-FA-0086C
240
1
34
1
28 (16)
HX-233-FA-0086J
208
3
23
1
28 (16)
HX-233-FA-0086D
240
3
20
1
28 (16)
HX-233-FA-0086K
480
3
10
1
28 (16)
HX-233-FA-0086U
600
3
9
1
28 (16)
HX-233-FA-0086Z
240
1
44
1
38 (21)
HX-233-FA-0106J
208
3
30
1
38 (21)
HX-233-FA-0106D
240
3
26
1
38 (21)
HX-233-FA-0106K
480
3
13
1
38 (21)
HX-233-FA-0106U
600
3
11
1
38 (21)
HX-233-FA-0106Z
208
3
44
2
27 (15)
HX-233-FB-0156D
240
3
38
2
27 (15)
HX-233-FB-0156K
480
3
19
2
27 (15)
HX-233-FB-0156U
600
3
16
2
27 (15)
HX-233-FB-0156Z
480
3
25
2
35 (19)
HX-233-FB-0206U
600
3
21
2
35 (19)
HX-233-FB-0206Z
480
3
31
3
26 (14)
HX-233-FC-0256U
600
3
25
3
26 (14)
HX-233-FC-0256Z
480
3
37
3
25 (13)
HX-233-FC-0306U
600
3
30
3
25 (13)
HX-233-FC-0306Z
(1) Total Amps = Heating element amps and motor amps.
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
12
Availability
(2)
AS
U N I T
233 Series
H E A T E R
Class I, Divisions 1 and 2, Groups C and D
Class II, Divisions 1 and 2, Groups F and G
Class I, Zones 1 and 2, Group IIB
Temperature Code T3C, 320°F (160°C)
Heater Listing 50 Hz
KW
2.5
6.3
8.4
12.5
16.7
21
25
Volts
Phase
Total
Amps (1)
Frame
Size
Approximate Air
Temperature Rise
°F (°C)
Catalog
Number
220
1
14
1
14 (8)
HX-233-FA-0036E
220
3
9
1
14 (8)
HX-233-FA-0036F
380
3
6
1
14 (8)
HX-233-FA-0036G
400
3
6
1
14 (8)
HX-233-FA-0036H
414
3
5
1
14 (8)
HX-233-FA-0036I
220
1
21
1
24 (13)
HX-233-FA-0056E
220
3
13
1
24 (13)
HX-233-FA-0056F
380
3
9
1
24 (13)
HX-233-FA-0056G
400
3
8
1
24 (13)
HX-233-FA-0056H
415
3
7
1
24 (13)
HX-233-FA-0056I
220
1
31
1
28 (16)
HX-233-FA-0076E
220
3
19
1
28 (16)
HX-233-FA-0076F
380
3
12
1
28 (16)
HX-233-FA-0076G
400
3
11
1
28 (16)
HX-233-FA-0076H
415
3
10
1
28 (16)
HX-233-FA-0076I
220
1
40
1
38 (21)
HX-233-FA-0096E
220
3
24
1
38 (21)
HX-233-FA-0096F
380
3
15
1
38 (21)
HX-233-FA-0096G
400
3
13
1
38 (21)
HX-233-FA-0096H
415
3
13
1
38 (21)
HX-233-FA-0096I
220
3
35
2
26 (14)
HX-233-FB-0136F
380
3
21
2
26 (14)
HX-233-FB-0136G
400
3
19
2
26 (14)
HX-233-FB-0136H
415
3
18
2
26 (14)
HX-233-FB-0136I
220
3
46
2
35 (19)
HX-233-FB-0176F
380
3
28
2
35 (19)
HX-233-FB-0176G
400
3
25
2
35 (19)
HX-233-FB-0176H
415
3
24
2
35 (19)
HX-233-FB-0176I
380
3
33
3
26 (14)
HX-233-FC-0216G
400
3
32
3
26 (14)
HX-233-FC-0216H
415
3
31
3
26 (14)
HX-233-FC-0216I
380
3
39
3
30 (17)
HX-233-FC-0256G
400
3
37
3
30 (17)
HX-233-FC-0256H
415
3
36
3
30 (17)
HX-233-FC-0256I
Availability
(2)
H E A T E R S
4.2
E X P L O S I O N - P R O O F
Explosion-Proof Unit Heater
C
(1) Total Amps = Heating element amps and motor amps.
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
13
233 Series
U N I T
H E A T E R
H E A T E R S
Explosion-Proof Unit Heater
E X P L O S I O N - P R O O F
Three Constructions to Choose From; Standard, Stainless Steel or Heresite®
Standard - Non-corrosive applications
Optional 316 Stainless Steel or Heresite® Coating
• Aircraft Hangars/Servicing Areas
• Coal Mines/Preparation Plants
• Gasoline Fueling/Storage Areas
• Paint Spraying/Storage Areas
• Utility Plants
• Chemical Plants
• Chemical Storage/Handling Areas
• Food Processing Plants
• Oil Refineries
• Petrochemical Plants
• Sewage Treatment/Wastewater Treatment Plants
Heavy 14-Gauge Cabinet
• Powder coated - standard
16 stainless steel or Heresite® coat •3
ed - options
Standard
• 24VAC transformer
• Contactor
• Automatic and manual
reset overtemperature
thermal cutouts
Adjustable louvers
Finger safe fan guard split construction for easy removal for
field servicing.
Optional
• Disconnect switch
with lockout
• Fan selector switch
• Thermostat
Thermally-protected
explosion-proof motor with
heavy-gauge aluminum fan
blade designed for easy field
servicing.
Designed for Easy Servicing
Heater Core
All welded construction with:
• Painted steel headers with steel tubes and spiral wound
aluminum fins - standard
• 316 stainless steel or heresite® construction - options
• Removable core
• Split fan guard
• Easy access to motor and fan
• Replaceable automatic and manual thermal cutouts
• Threaded control enclosure
Heresite® is a registered trademark of Heresite® Protective Coatings, Inc.
14
Core can be easily removed through bottom of cabinet
U N I T
H E A T E R
®
Class I, Divisions 1 and 2, Group D
Class I, Zones 1 and 2, Group IIA
American
Bureau of
Shipping
HEATREX’s 236 Series explosion-proof unit heater is
designed with both size and economy in mind. Advantages
and unique features include:
• Compact Size: This small design is only 13 inches wide,
which makes it ideal for applications where limited space
is available.
Applications
•Chemical Storage/Handling
Areas
•Oil Platforms and Refineries
•Compressor Stations
•Sewage/Wastewater
Treatment Plants
• Marine and Offshore
•Spray Booths
• Redundant Overtemperature Protection: Primary and
secondary automatic reset thermal cutouts for additional
safety.
• Stainless Steel Construction: Provides superior corrosion
resistant protection. Optional Dirty Duty construction
adds polyester powder coating to all aluminum parts for
use in corrosive applications.
H E A T E R S
• Low Cost: The design offers the most economical solution for heating small Class I, Group D hazardous areas.
It is a cost effective alternative to the use of explosionproof convection heaters.
E X P L O S I O N - P R O O F
236 Series
• Optional Marine Duty Construction: Ideal for shipboard
use where size, weight and corrosion resistant construction are critical.
Standard Construction Features
Heating Elements – Industrial grade, Type 304 stainless
steel finned tubular heating elements are manufactured
by HEATREX.
Terminal Enclosure – A NEMA 7, 9 cast aluminum enclosure
with a threaded bottom cover permits easy access to the
built-in controls from underneath the heater.
Housing – Round, 16-gauge stainless steel shroud.
Grilles – An adjustable stainless steel louvered outlet grille
directs airflow 45° up or down and a heavy gauge stainless
steel rear grille protects against accidental contact with the
fan blade.
Stainless Steel Swivel Mounting Bracket – Supplied as
standard with all 236 Series explosion-proof unit heaters.
This multi-purpose bracket can be used for either wall or
ceiling mounting.
Built-In Controls – Include primary and secondary automatic reset overtemperature cutouts, controlling contactor, and a time delay relay which keeps the fan running
to cool the heating elements after they have been deenergized.
Fan Motor Assembly – Consists of a 120-volt, 1-phase 60
hertz motor fitted with an aluminum fan blade. The totally
enclosed motor is UL Listed for Class I, Group D applications and includes permanently lubricated ball bearings
and built-in thermal overload protection. The motor is factory wired into the enclosure to reduce field wiring, but
requires a separate 120-volt power supply.
15
H E A T E R S
236 Series
U N I T
H E A T E R
Custom Options
Code
Option
Dirty Duty Corrosion
Resistant Construction
Includes polyester powder coated fan blade, wiring
conduit and fittings, NEMA 4X, 7, 9 enclosure.
C
CM
Marine Duty
Construction
Dirty Duty Construction with manual reset thermal cutout. Meets U.S. Coast Guard requirements per 46CFR111.87 and is ABS Approved
C
M
Manual Reset Cutout
Can be specified to replace secondary automatic cutout.
C
T
Adjustable Thermostat
Factory installed and prewired to the control enclosure.
Thermostat is adjustable from 50° to 90°F (10° to 32°C)
range.
C
C
E X P L O S I O N - P R O O F
Availability
Code (2)
Description
(2) AS = Assembly Stock, C = Custom Assembly Stock heaters ordered with custom options are subject to longer delivery.
Dimensions, Airflows and Weights
KW
3
5
7
10
12
Ignition Temperature Code
T3
T2C
T2
T1
T1
9 (5)
15 (8)
22 (12)
31 (17)
37 (21)
Air Volume CFM
(cubic meters/hr)
1050
(1784)
1050
(1784)
1050
(1784)
1050
(1784)
1050
(1784)
Air Throw Feet (m)
25 (8)
25 (8)
25 (8)
25 (8)
25 (8)
Outlet Velocity FPM
(meters/min)
1140
(348)
1140
(348)
1140
(348)
1140
(348)
1140
(348)
RPM
1725
1725
1725
1725
1725
HP
1/6
1/6
1/6
1/6
1/6
Approximate Air Temperature Rise °F (°C)
Airflow
Characteristics
Motor/Fan
Fan Blade Dia. Inch ( cm)
12 (31)
Net Lbs (kgs)
96 (44)
Shipping Lbs (kgs)
110 (50)
Weight
CEILING
CEILING
8” Min
(20.3 cm)
120V Motor:
Control Wiring When
Optional Built-On
Thermostat is Used
5 ¾”
(14.6 cm)
15 16”
(3.3 cm)
Min
Swivel Bracket
(Ceiling Mounted)
WALL
Optional Built-On
Thermostat
9 ¼”
(48.9 cm)
AIRFLOW
20”
(50.8 cm)
8” Min
(20.3 cm)
4⅜”
(11.1 cm)
Min
120V Motor:
Control Wiring
When Optional
Built-OnThermostat is Used
Heater
Wiring
22”
(55.9 cm)
28 ¼”
(71.8 cm)
Max
18” Ref.
(45.7 cm)
Standard Wall and Ceiling Installation with Swivel Mounting Bracket
Remote Room Thermostat – Use catalog number 1007002. See page 98.
16
13”
(33 cm)
U N I T
T2
572 (300)
T1
842 (450)
T1
842 (450)
5
7
10
12
Volts
Phase
Heater
Amps
(1)
Catalog
Number
208
1
14.5
HX-236-F01T-0037C-7000
C
240
1
12.5
HX-236-F01T-0037J-7001
C
480
1
6.3
HX-236-F01T-0037T-7002
C
208
3
8.4
HX-236-F01T-0037D-7003
C
240
3
7.3
HX-236-F01T-0037K-7004
C
480
3
3.7
HX-236-F01T-0037U-7005
C
600
3
2.9
HX-236-F01T-0037Z-7006
C
208
1
24.1
HX-236-F01T-0055C-7007
C
240
1
20.9
HX-236-F01T-0055J-7008
C
480
1
10.5
HX-236-F01T-0055T-7009
C
208
3
13.9
HX-236-F01T-0055D-7010
C
240
3
12.1
HX-236-F01T-0055K-7011
C
480
3
8.1
HX-236-F01T-0055U-7012
C
600
3
4.9
HX-236-F01T-0055Z-7013
C
208
1
33.7
HX-236-F01T-0072C-7021
C
240
1
29.2
HX-236-F01T-0072J-7022
C
480
1
14.6
HX-236-F01T-0072T-7023
C
208
3
19.5
HX-236-F01T-0072D-7024
C
240
3
16.9
HX-236-F01T-0072K-7025
C
480
3
8.5
HX-236-F01T-0072U-7026
C
600
3
6.8
HX-236-F01T-0072Z-7027
C
240
1
41.7
HX-236-F01T-0101J-7035
C
480
1
20.9
HX-236-F01T-0101T-7036
C
208
3
27.8
HX-236-F01T-0101D-7037
C
240
3
24.1
HX-236-F01T-0101K-7038
C
480
3
12.1
HX-236-F01T-0101U-7039
C
600
3
9.7
HX-236-F01T-0101Z-7040
C
480
1
25.0
HX-236-F01T-0121T-7041
C
240
3
29.0
HX-236-F01T-0121K-7042
C
480
3
14.5
HX-236-F01T-0121U-7043
C
600
3
11.6
HX-236-F01T-0121Z-7044
C
Availability
Code (2)
®
American
Bureau of
Shipping
H E A T E R S
T2C
446 (230)
3
E X P L O S I O N - P R O O F
T3
392 (200)
KW
236 Series
Class I, Divisions 1 and 2, Group D
Class I, Zones 1 and 2, Group IIA
Heater Listing
Ignition
Temperature
Code
°F (°C)
H E A T E R
(1) The amps shown are for the heating elements only. The 120V, 1 Ph 60 Hz motor draws 3.8 amps and requires a separate 120V power supply.
(2) Availability Code: C = Custom
17
H E A T E R S
254 Series
®
E X P L O S I O N - P R O O F
American
Bureau of
Shipping
Class I, Divisions 1 and 2, Groups B, C and D
Class II, Divisions 1 and 2, Groups E, F and G
Class I, Zones 1 and 2, Group IIC
Applications
•Battery Storage Areas
•Chemical Plants
•Coal Handling Facilities
•Dry Cleaning Plants
•Gasoline Fueling/Storage Areas
• Grain Elevators
• Oil Refineries
• Paint Spraying/Storage Areas
• Petrochemical Plants
HEATREX’s explosion-proof convector is designed to
provide a heavy duty and corrosion resistant heat
source. Features include:
• Wide Selection of Sizes: Four compact sizes to fit any
space with ratings from 500 to 9,500 watts.
• Sloped Top Cabinet: Prevents objects from being set
on top of the convector, which can restrict airflow and
cause overheating.
• Single and Three-Phase: Unique design provides single
and balanced three-phase loads in a single element.
• Gas and Dust Atmospheres: Three listings cover the
entire field, two for hazardous gases and vapors and
one for dust particles.
• Wet Locations: All unit sizes available with iriditecoated elements and powder-coated frames for NEMA
3 wet locations.
Standard Construction Features
Element – Grade A Nickel-Chromium heating coils are insulated with ceramics and magnesium oxide from the copper
heater tube and fitted with large aluminum fins locked in
place.
Cabinet – Heavy gauge galvanized steel cabinet is painted
with a beige powder coat for durability. Cabinet should
be mounted at least 6 inches (152 mm) above the floor.
Factory-furnished wall brackets make installation easy.
18
Thermal Protection – A linear limit, automatic reset thermal cutout is built into every unit.
Complete Electrical Package – For larger single-phase and
all three-phase units, a built-on contactor and transformer
option package are available.
254 Series
All single-phase heaters rated over 22 amps or 277 volts
and all three-phase heaters require a magnetic contactor. Some electrical combinations will also require a
control transformer. To simplify field installation, these
Code
accessories are factory-mounted on the heater cabinet and
factory pre-wired (not available on Size 1 convectors).
Option
Description
Availability
Code (2)
Electric Control Option (1)
(without thermostat)
Classes I and II, Groups B, C, E, D, F and G includes contactor and
transformer (as required). Required for all three-phase and single-phase
heaters over 22 amps or 277 volts
AS
B2/S1
Thermostat & Controls (1)
Classes I and II, Groups C, D, E, F and G includes thermostat, contactor
and transformer (as required).
AS
B3
Thermostat & Controls
(Group B) (1)
Classes I and II, Groups B, C, D, E, F and G includes thermostat, contactor and transformer (as required). Thermostat has internal set point.
AS
S1
Thermostat Only (1)
Classes I and II, Groups C, D, E, F and G single-phase heaters rated up to
22 amps at 120-277 volts. Use remote room thermostat Catalog Number 1007002 for Size 1 convectors.
AS
S2
Thermostat Only
(Group B) (1)
Classes I and II, Groups B, C, D, E, F and G single-phase heaters rated up
to 22 amps at 120-277 volts. Thermostat has internal set point. Use remote room thermostat Catalog Number 1007022 for Size 1 convectors.
AS
Description
Availability
Code (2)
H E A T E R S
B2
E X P L O S I O N - P R O O F
Electrical Package Options
(1) These options are not available on Size 1 Convectors.
Custom Option
Code
C1
Option
NEMA 3 rated heater construction not available with S1, B2/S1 and S2
thermostat options.
Wet Locations
C
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
Dimensions and Weights
Unit Size
Dimensions - In. (cm)
Weight - Lb (kg)
Length (L)
Height (H)
Depth (D)
Without Controls
1
26 (66)
6 (15)
4 ½ (11)
13 (5.9)
2
26 (66)
16 (41)
8 (20)
27 (12.2)
3
39 (99)
16 (41)
8 (20)
36 (16.3)
4
67 ½ (171)
16 (41)
8 (20)
60 (27.2)
Remote Room Thermostat - See page 98.
Thermostat
(Ifpec
S ifie
Control
Package
Option: B2/S1
19
E X P L O S I O N - P R O O F
H E A T E R S
254 Series
®
Heater Listing
Class I, Divisions 1 and 2, Groups B, C and D
Class I, Zones 1 and 2, Group IIC
Ignition
Temperature
Code
°F (°C)
KW
0.5
1
1.8
2.5
T2A
536
(280)
3.6
4.4
6.5
7.5
9.5
Magnetic contactor required.
20
American
Bureau of
Shipping
Volts/
Phase
Heater
Amps
Unit
Size
Catalog
Number
120/1
4.2
1
HX-254-F0310052B
208/1
2.4
1
HX-254-F0310052C
240/1
2.1
1
HX-254-F0310052J
120/1
8.3
1
HX-254-F0310102B
208/1
4.8
1
HX-254-F0310102C
240/1
4.2
1
HX-254-F0310102J
120/1
15.0
2
HX-254-F0320182B
208/1
8.7
2
HX-254-F0320182C
240/1
7.5
2
HX-254-F0320182J
480/3▲
1.3
2
HX-254-F0320182U
600/3▲
1.8
2
HX-254-F0320182Z
208/1
12.0
2
HX-254-F0320252C
240/1
10.4
2
HX-254-F0320252J
208/3
6.9
2
HX-254-F0320252D
480/3▲
3.0
2
HX-254-F0320252U
600/3▲
2.4
2
HX-254-F0320252Z
208/1
17.3
3
HX-254-F0330362C
240/1
15.0
3
HX-254-F0330362J
208/3
10.0
3
HX-254-F0330362D
480/3▲
4.3
3
HX-254-F0330362U
600/3▲
3.5
3
HX-254-F0330362Z
240/1
18.3
3
HX-254-F0330442J
208/3
12.2
3
HX-254-F0330442D
480/3
5.3
3
HX-254-F0330442U
600/3▲
4.3
3
HX-254-F0330442Z
240/1
27.1
4
HX-254-F0340652J
208/3
18.0
4
HX-254-F0340652D
480/3▲
7.8
4
HX-254-F0340652U
600/3▲
6.3
4
HX-254-F30340652Z
240/1
31.3
4
HX-254-F0340752J
208/3
20.8
4
HX-254-F0340752D
480/3▲
9.0
4
HX-254-F0340752U
600/3▲
7.2
4
HX-254-F0340752Z
240/1
39.6
4
HX-254-F0340852J
208/3
26.4
4
HX-254-F0340962D
480/3▲
11.4
4
HX-254-F0340952U
600/3▲
9.1
4
Availability
Code (2)
AS
HX-254-F0340952Z
▲Magnetic contactor and control transformer required.
These accessories may be field mounted. For factory mounting, see Electrical Package Options on page 19.
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
Other voltages available. Consult factory.
254 Series
®
Class I, Divisions 1 and 2, Groups B, C and D
Ignition
Temperature
Code °F (°C)
KW
0.5
1.4
2.3
3.2
5
Volts/
Phase
Heater
Amps
Unit
Size
Catalog
Number
120/1
4.2
1
HX-254-F0610052B
208/1
240/1
120/1
208/1
240/1
120/1
208/1
240/1
208/3
480/3▲
2.4
2.1
11.7
6.7
5.8
19.2
11.1
9.6
6.4
2.8
1
1
2
2
2
3
3
3
3
3
HX-254-F0610052C
HX-254-F0610052J
HX-254-F0620142B
HX-254-F0620142C
HX-254-F0620142J
HX-254-F0630232B
HX-254-F0630232C
HX-254-F0630232J
HX-254-F0630232D
HX-254-F0630232U
600/3▲
2.2
3
HX-254-F0630232Z
208/1
240/1
208/3
480/3▲
15.4
13.3
8.9
3.8
4
4
4
4
HX-254-F0640322C
HX-254-F0640322J
HX-254-F0640322D
HX-254-F0640322U
600/3▲
3.1
4
HX-254-F0640322Z
240/1
208/3
480/3▲
20.8
13.9
6.0
4
4
4
HX-254-F0640502J
HX-254-F0640502D
HX-254-F0640502U
600/3▲
4.8
4
HX-254-F0640502Z
Availability
Code (2)
AS
H E A T E R S
T3A
356
(180)
American
Bureau of
Shipping
E X P L O S I O N - P R O O F
Heater Listing
Class I, Divisions 1 and 2, Groups B, C and D
Class II, Divisions 1 and 2, Groups E, F and G
Ignition
Temperature Code
°F (°C)
KW
0.5
1
T3C
320
(160)
1.7
3.2
Volts/
Phase
Heater
Amps
Unit
Size
Catalog
Number
120/1
208/1
240/1
120/1
208/1
240/1
120/1
208/1
240/1
480/3▲
4.2
2.4
2.1
8.3
4.8
4.2
14.2
8.2
7.1
2.0
1
1
1
2
2
2
3
3
3
3
HX-254-F0810054B
HX-254-F0810054C
HX-254-F0810054J
HX-254-F0820104B
HX-254-F0820104C
HX-254-F0820104J
HX-254-F0830174B
HX-254-F0830174C
HX-254-F0830174J
HX-254-F0830174U
600▲
1.6
3
HX-254-F0830174Z
208/1
240/1
208/3
480/3▲
15.4
13.3
8.9
3.8
4
4
4
4
HX-254-F0840324C
HX-254-F0840324J
HX-254-F0840324D
HX-254-F0840324U
600/3▲
3.1
4
HX-254-F0840324U
Magnetic contactor required.
▲Magnetic contactor and control transformer required.
These accessories may be field mounted. For factory mounting, see
Electrical Package Options on page 19.
Availability
Code (2)
AS
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters
ordered with custom options are subject to longer delivery.
Other voltages available. Consult factory.
21
Comparison Chart
H E A T E R S
Unit Heaters
928
926
F A N - F O R C E D
240
924
234
238
Features
Typical
Applications
Food processing
plants
Marine duty
Wastewater
treatment plants
238 Series
240 Series
926 Series
924 Series
Factories
Factories
Mechanical
rooms
Mechanical
rooms
Mechanical rooms
Warehouses
Storage rooms
Workshops
Workshops
Warehouses
Vertical
928 Series
Gyms
High bay areas
Warehouses
KW Range
2 to 47
3 to 38.4
3.3 to 50
2 to 60
3 to 5
5 to 30
Voltages
up to 600/3
Up to 480/3
Up to 480/3
Up to 480/3
240/208/1
Up to 480/3
Airflow CFM
Up to 2400
Up to 1774
Up to 3100
Up to 2000
300
Up to 2300
Discharge
Horizontal
Horizontal
Horizontal or
Vertical
Horizontal or
Vertical
Horizontal
Vertical
Element Type
Stainless steel
finned tubular
Stainless steel
finned tubular
Stainless steel
finned tubular
Stainless steel
tubular or steel
finned tubular
Stainless steel
tubular
Steel finned
tubular
Standard
Construction
22
Washdown
234 Series
16 gauge stain16 gauge galvaless steel shroud
nized steel shroud
and non-metallic
and control
NEMA 4X control
enclosure
enclosure
20-14 gauge
(depending on 8 & 20 gauge steel 20 gauge galva18 gauge galvasize) galvanized
cabinet
nized steel cabinet nized steel cabinet
steel cabinet
Finish
Stainless steel
Beige polyester
powder paint
Camel polyester
powder paint
Almond
polyester
powder paint
Almond
polyester
powder paint
Almond
polyester
powder paint
Mounting
Ceiling or wall
Ceiling or wall
Ceiling or wall
Ceiling or wall
Ceiling or wall
Ceiling
Agency
Approvals
cULus & ABS
cULus
cULus
CSAus
CSAus
CSAus
234 Series
The HEATREX 234 Series unit heater is the perfect solution
to the problem of heating people or equipment in non-hazardous environments where moisture and corrosion exist.
Advantages include:
Applications
•Marine and Offshore
•Car Washes
•Power Generating Stations
•Cement Plants
•Steel Mills and Foundries
•Coal Handling Areas
•Swimming Pool Areas
•Dairies
•Wastewater Treatment
Plants
•Food Processing Plants
H E A T E R S
American
Bureau of
Shipping
F A N - F O R C E D
Washdown/Corrosion Resistant Unit Heater
• Built-in Controls: All necessary safety and temperature
controls are included in a single package. Components
and motor are factory-wired to a single terminal block
for field wiring, eliminating the chance for field error and
reducing installation costs.
• Single Point Electrical Hook-up: Heater, fan motor and
controls are all connected to the same branch circuit.
• Corrosion Resistant: Stainless steel construction, powdercoated aluminum fan blade and nonmetallic NEMA 4X
terminal enclosure resist corrosion found in sewage treatment plants, swimming pool areas, car washes, paper
mills and marine installations.
• Washable: This watertight construction can be hosed
down without disconnecting the heater, which makes it
ideal for coal handling areas, steel mills, foundries, ships,
wood finishing plants, cement, sand, grain and food processing facilities.
Standard Construction Features
Heating Elements – Industrial grade, Type 316 stainless steel
tubular elements with stainless steel fins, manufactured by
HEATREX.
Control Enclosure – The non-metallic enclosure, which
houses the element terminals and built-in controls, will
not rust and meets NEMA 4X hose-down requirements.
Fan Motor Assembly – Totally enclosed, epoxy coated, UL
Recognized motor with permanently lubricated ball bearings
for longer life. Designed to resist moisture and corrosion.
Factory-wired to NEMA 4X enclosure. Fitted with a powdercoated, aluminum fan blade suitable for corrosive salt spray
environments.
Built-in Controls – Include automatic reset overtemperature cutout, fan delay relay, controlling contactor, transformer for 24-volt control circuit, terminal block for field
wiring and a separate motor contactor (when required).
Housing – Heating elements and motor are enclosed in a
round, heavy 16-gauge stainless steel shroud.
Inlet/Outlet Grilles – Adjustable, stainless steel, louvered
outlet grille can be rotated 90° to direct airflow up, down,
left or right. Heavy gauge, stainless steel rear grille protects
against accidental contact with the fan blade.
Mounting Bracket – The heater comes complete with a
stainless steel swivel mounting bracket which can be used
either for wall or ceiling mounting. Four field-supplied
3/8-16 threaded rods can also be used for ceiling installation.
23
F A N - F O R C E D
H E A T E R S
234 Series
Washdown/Corrosion Resistant Unit Heater
Factory Built-in Options
Code
Availability
Code (2)
Description
B
Delete swivel mounting bracket. Heater installs from the ceiling with field furnished
threaded rods.
AS
C
Epoxy painted stainless steel parts, housing, grilles and fan blade
C
D
Power disconnect switch
AS
E
Monel finned tubular elements
C
L
“Heater on” pilot light
AS
M
Secondary manual reset overtemperature cutout. Required for U.S. Coast Guard and
ABS Approved designs.
AS
S
Three-position selector switch (heater-standby-fan)
AS
1- Stage Built-in thermostat 40 to 100° F (5 to 38° C) range
AS
2- Stage Built-in thermostat 40 to 120° F (5 to 49° C) range (Option “X” required)
C
V
120 volt control circuit, fused secondary and grounded
AS
X
2-Stage Control
C
T
(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.
Remote Room Thermostat – See page 98.
KW
Dimensions, Airflows and Weights
Overall
Heater
Dimensions
Mounting
Hole
Dimensions
Airflow
Characteristics
Weight
2 - 7.5
7.6 - 12
12.1 - 47
“X” Inch (cm)
15½ (39)
15½ (39)
26 (66)
“Y” Inch (cm)
21½ (55)
21½ (55)
28 (71)
“Z” Inch (cm)
13 (33)
13 (33)
20 (51)
“BH” Inch (cm)
4¼ (11)
4¼ (11)
7⅛ (18)
“BL” Inch (cm)
19½ (50)
19½ (50)
22¼ (57)
“M” Inch (cm)
8½ (22)
8½ (22)
3¼ (8)
Air Volume CFM (cubic meters/hr)
700 (1189)
1450 (2463)
2400 (4077)
Air Throw Feet (m)
26 (8)
43 (13)
50 (15)
Outlet Velocity FPM (meters/min)
760 (232)
1575 (481)
1200 (366)
Net Lbs (kgs)
56 (25)
56 (25)
115 (52)
Shipping Lbs (kgs)
70 (32)
70 (32)
130 (60)
Ceiling
Swivel Bracket
(Wall Mounting)
8” Min
Ceiling
Z
Four 3/8 - 16
threaded rods
(not supplied
with the
heater)
Swivel
Bracket
(Ceiling
Mounting)
BL
BH
Wall
8”
Min.
8” Min.
8”
Min.
Y
24
Standard Wall and Ceiling Installation with Swivel
Mounting Bracket
Wall
X
Conduit Opening
For Field Wiring
6 Foot Min
(Any Mounting)
Floor
Wall
M
Optional Ceiling
Installation with Four
Threaded Rods
234 Series
Heater Listing
KW
2
5
7.5
9
10
12
12.5
15
20
25
30
35
38.4
47
Volts
Ph
Total
Amps
(1)
Approximate Air
Temperature Rise
°F (°C)
HP
Volts
Ph
120
208
240
277
120
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
240
277
480
208
240
480
600
277
480
208
240
480
600
208
240
480
600
208
240
480
600
480
600
480
600
480
600
480
600
480
600
600
1
1
1
1
1
1
1
1
1
3
3
3
3
1
1
1
1
3
3
3
3
1
1
1
1
3
3
3
3
1
1
1
1
3
3
3
3
1
1
1
3
3
3
3
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
21
12
11
10
29
17
15
13
8
11
10
5
4
27
23
20
12
16
15
8
6
39
34
29
17
23
21
11
9
46
40
35
20
28
24
12
10
44
39
22
30
27
14
11
46
27
36
32
16
13
37
33
17
14
44
39
20
16
26
21
32
26
38
31
44
35
48
38
47
9 (5)
9 (5)
9 (5)
9 (5)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
24 (13)
24 (13)
24 (13)
24 (13)
24 (13)
24 (13)
24 (13)
24 (13)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
20 (11)
20 (11)
20 (11)
20 (11)
20 (11)
20 (11)
20 (11)
20 (11)
22 (12)
22 (12)
22 (12)
22 (12)
22 (12)
22 (12)
22 (12)
26 (14)
26 (14)
26 (14)
26 (14)
26 (14)
26 (14)
17 (9)
17 (9)
17 (9)
17 (9)
21 (12)
21 (12)
21 (12)
21 (12)
28 (16)
28 (16)
35 (19)
35 (19)
42 (23)
42 (23)
48 (27)
48 (27)
54 (30)
54 (30)
64 (36)
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
120
208
240
277
120
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
208
240
277
480
208
240
480
600
240
277
480
208
240
480
600
277
480
208
240
480
600
208
240
480
600
208
240
480
600
480
600
480
600
480
600
480
600
480
600
600
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Motor
Catalog
Number
2-Stage
Control
HX-234-U11R-0020B
HX-234-U11R-0020C
HX-234-U11R-0020J
HX-234-U11R-0020N
HX-234-U11N-0030B
HX-234-U11N-0030C
HX-234-U11N-0030J
HX-234-U11N-0030N
HX-234-U11N-0030T
HX-234-U11N-0030D
HX-234-U11N-0030K
HX-234-U11N-0030U
HX-234-U11N-0030Z
HX-234-U11R-0050C
HX-234-U11R-0050J
HX-234-U11R-0050N
HX-234-U11R-0050T
HX-234-U11N-0050D
HX-234-U11N-0050K
HX-234-U11N-0050U
HX-234-U11N-0050Z
HX-234-U11N-0080C
HX-234-U11N-0080J
HX-234-U11N-0080N
HX-234-U11N-0080T
HX-234-U11N-0080D
HX-234-U11N-0080K
HX-234-U11N-0080U
HX-234-U11N-0080Z
HX-234-U11N-0090C
HX-234-U11N-0090J
HX-234-U11N-0090N
HX-234-U11N-0090T
HX-234-U11N-0090D
HX-234-U11N-0090K
HX-234-U11N-0090U
HX-234-U11N-0090Z
HX-234-U11N-0100J
HX-234-U11N-0100N
HX-234-U11N-0100T
HX-234-U11N-0100D
HX-234-U11N-0100K
HX-234-U11N-0100U
HX-234-U11N-0100Z
HX-234-U11N-0120N
HX-234-U11N-0120T
HX-234-U11N-0120D
HX-234-U11N-0120K
HX-234-U11N-0120U
HX-234-U11N-0120Z
HX-234-U11L-0130D
HX-234-U11L-0130K
HX-234-U11L-0130U
HX-234-U11L-0130Z
HX-234-U11L-0150D
HX-234-U11L-0150K
HX-234-U11L-0150U
HX-234-U11L-0150Z
HX-234-U11L-0200U
HX-234-U11L-0200Z
HX-234-U11A-0250U
HX-234-U11A-0250Z
HX-234-U11A-0300U
HX-234-U11A-0300Z
HX-234-U11A-0350U
HX-234-U11A-0350Z
HX-234-U11A-0390U
HX-234-U11A-0390Z
HX-234-U11A-0470Z
1B
1B
1B
1B
1B
1B
1B
1B
1B
1A
1A
1A
1A
1B
1B
1B
1B
1A
1A
1A
1A
1B
1B
1B
1B
1A
1A
1A
1A
1B
1B
1B
1B
1A
1A
1A
1A
1B
1B
1B
1A
1A
1A
1A
1A
1B
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1B
1B
1B
1B
1B
1B
1B
1B
1B
Availability
Code (2)(3)
American
Bureau of
Shipping
H E A T E R S
3
For Non-Hazardous Areas
F A N - F O R C E D
Washdown/Corrosion Resistant Unit Heater
AS
(1) Total Amps = Heating
element amps and motor
amps.
(2) Availability Code: AS =
Assembly Stock,
(3) Stock heaters ordered
with custom options subject to longer delivery.
NOTE: 2-Stage heaters
can be field wired as
single stage.
1A = Optional 2-stage
control, unbalanced
(option ‘X’).
1B = Optional 2-stage control, balanced (option ‘X’)
25
Industrial Unit Heater
F A N - F O R C E D
H E A T E R S
238 Series
HEATREX’s industrial unit heater is designed for maximum heating performance in non-hazardous and noncorrosive environments. Features include:
• Unique Design: Round design of the industrial unit heater
provides uniform airflow over the elements to prevent
hot spots and ensure even discharge temperatures.
Circular stainless steel finned tubular elements have a
longer life due to lower operating temperatures.
• Built-in Controls: Heaters are completely assembled with
all electrical components built-in at the factory to reduce
installation costs.
Applications
•Aircraft Hangars
•Power Generating Stations
•Entryways
•Pump Houses
•Factories
•Service Stations
•Garages
• Improved Performance: High CFM’s and air throw up
to 50 feet promote air circulation within the space. More
uniform temperature increases comfort levels and helps
to eliminate cold spots.
• Single Point Electrical Hook-up: Heater, fan motor and
controls are all connected to the same branch circuit.
Standard Construction Features
Heating Elements – Industrial grade, Type 304 stainless steel
finned tubular elements, manufactured by HEATREX.
Housing – Heating elements and motor are enclosed in a
round, 16-gauge galvanized steel enclosure which has a powder coat finish for durability.
Inlet/Outlet Grilles – Inlet grille complies with OSHA requirements for fan blade guard. Outlet grille has 45° angled louvers
to direct airflow.
Fan Motor – Motor is UL Recognized with built-in
26
thermal protection.
Built-in Controls – Include main control magnetic contactor,
control voltage transformer, automatic reset thermal cutout and fan thermostat.
Mounting Bracket – Wall mounting bracket with single point
suspension allows the heater to rotate a full 360°.
238 Series
Factory Built-in Options
Code
No mounting bracket
Substitute wall mounting bracket with ceiling bracket
Power Disconnect Switch
Adjustable Outlet Louvers
Premium Fan Motor
“Heater On” Pilot Light
Manual Reset Thermal Cutout
Built-in Fan Relay - Required for Remote Fan Switch
Three-position Selector Switch (Heater-Standby-Fan)
Built-in Thermostat 40° to 120° F (4° to 49° C) Range
No Transformer - Customer supplied control voltage
AS
AS
AS
C
AS
AS
AS
AS
AS
AS
AS
(2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery.
H E A T E R S
B
C
D
G
H
L
M
R
S
T
X
Availability
Code (2)
Description
F A N - F O R C E D
Industrial Unit Heater
Dimensions, Weights and Air Throws
Dimensions - In. (cm)
M
W
X
Y
Z
Weight
Lb (kgs)
1 - 12
8¼ (21)
8¾ (22)
15 (38)
17 (43)
13 (41)
45 (20)
15 (5)
12.5 - 20
7 (18)
5½ (14)
16¼ (41)
23½ (60)
19¼ (49)
60 (27)
50 (15)
25 - 38.4
4 (10)
5½ (14)
20¾ (53)
23½ (60)
19¼ (49)
80 (36)
50 (15)
KW
Maximum Air
Throw-Ft. (m)
CEILING
Minimum
2 Ft.
Maintenance
Access
Two 3/8-16
threaded rods
(not supplied
with the
heater)
Wall mounting
bracket
Ceiling
mounting bracket
WALL
WALL
6 In.
Y
Airflow
X
Minimum
W
Z
6 Ft.
Minimum to floor
(any mounting)
Motor Data
Description
RPM
Standard
Premium
Airflow - CFM (cubic meters/hr)
Noise Level (dB)
1-12 KW
12.5-20 KW
25-38.4 KW
1-12 KW
12.5-20 KW
25-38.4 KW
1200
362 (615)
1342 (2280)
1237 (2102)
64
68
68
1800
618 (1050)
1774 (3014)
1635 (2778)
75
84
84
27
F A N - F O R C E D
H E A T E R S
238 Series
Industrial Unit Heater
For Non-Hazardous Areas
For Non-Corrosive Areas
Heater Listing
KW
3
5
7.5
9
10
12
12.5
15
20
25
30
35
38.4
Motor
Volts
Phase
Total
Amps (1)
Approximate Air
Temperature Rise
°F (°C)
HP
Volts
Phase
Catalog
Number
208
240
480
208
1
1
1
3
17
15
8
11
21 (12)
21 (12)
21 (12)
21 (12)
1/4
1/4
1/4
1/4
208
240
480
208
1
1
1
1
HX-238-UT03C
HX-238-UT03J
HX-238-UT03T
HX-238-UT03D
240
480
208
240
480
208
240
480
208
240
480
208
3
3
1
1
1
3
3
3
1
1
1
3
10
5
27
23
12
16
15
8
39
34
17
23
21 (12)
21 (12)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
53 (29)
53 (29)
53 (29)
53 (29)
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
240
480
208
240
480
208
240
480
208
240
480
208
1
1
1
1
1
1
1
1
1
1
1
1
HX-238-UT03K
HX-238-UT03U
HX-238-UT05C
HX-238-UT05J
HX-238-UT05T
HX-238-UT05D
HX-238-UT05K
HX-238-UT05U
HX-238-UT08C
HX-238-UT08J
HX-238-UT08T
HX-238-UT08D
240
480
208
240
480
208
240
480
240
480
3
3
1
1
1
3
3
3
1
1
21
11
46
40
20
28
24
12
44
22
53 (29)
53 (29)
64 (36)
64 (36)
64 (36)
64 (36)
64 (36)
64 (36)
70 (39)
70 (39)
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
240
480
208
240
480
208
240
480
240
480
1
1
1
1
1
1
1
1
1
1
HX-238-UT08K
HX-238-UT08U
HX-238-UT09C
HX-238-UT09J
HX-238-UT09T
HX-238-UT09D
HX-238-UT09K
HX-238-UT09U
HX-238-UT10J
HX-238-UT10T
208
3
30
70 (39)
1/4
208
1
HX-238-UT10D
240
3
27
70 (39)
1/4
240
1
HX-238-UT10K
480
480
208
240
480
208
240
480
208
240
480
480
480
480
480
480
3
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
14
27
36
32
16
37
33
17
44
39
20
26
32
38
44
48
70 (39)
62 (34)
62 (34)
62 (34)
62 (34)
31 (17)
31 (17)
31 (17)
38 (21)
38 (21)
38 (21)
35 (19)
66 (37)
79 (44)
61 (34)
70 (39)
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
480
480
208
240
480
208
240
480
208
240
480
480
480
480
480
480
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
HX-238-UT10U
*HX-238-UT12T
*HX-238-UT12D
*HX-238-UT12K
*HX-238-UT12U
HX-238-UL13D
HX-238-UL13K
HX-238-UL13U
HX-238-UL15D
HX-238-UL15K
HX-238-UL15U
*HX-238-UL20U
HX-238-UA25U
HX-238-UA30U
*HX-238-UA35U
*HX-238-UA39U
* Premium motor comes standard with heater.
(1) Total Amps = Heating element amps and motor amps.
(2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery.
28
Availability
Code (2)
AS
240 Series
F A N - F O R C E D
Unit Heater
H E A T E R S
The 240 Series unit heater is available in 50 standard models with ratings up to 50 KW at voltages of 208, 240, 277,
and 480 single or three-phase. They are available with a
wide variety of factory built-in or field-installed options.
Temperature Control: Single-stage or two-stage control
with built-in or remote-mounted thermostats are available
on all heaters.
Control Options: Available as factory built-in or fieldinstalled to meet job specifications.
Custom KW’s: Custom KW’s are available up to 50 KW.
Applications
• Factories
• Shipping and Receiving Areas
• Garages
• Storage Areas
• Mechanical Rooms
• Warehouses
• Pump Houses
• Workshops
• Service Areas in Air
Handling Units
Discharge Direction: Heater can be mounted for horizontal or vertical discharge using an optional universal wall/
ceiling mounting bracket or with field-furnished threaded
rods for ceiling mounting.
Color Options: The standard color is camel. Six optional
colors are available: grey, yellow, red, white, blue or textured beige. Heaters may also be supplied with unpainted
corrosion resistant galvanized steel. See back cover for
color samples.
Standard Construction Features
Heating Elements - Industrial grade, 0.475” diameter steel sheath with brazed copper plated steel fins
and epoxy sealed ends. Draw-thru airflow design
pulls air across the heating elements to ensure cool
element operation and even air distribution resulting
in long element life.
Housing - Heating elements and motor are enclosed
in a heavy gauge galvanized steel cabinet with a
durable polyester powder coat finish.
Outlet Grille - Individually adjustable louvers are
provided to direct airflow. A protective outlet fan
guard is provided to prevent insertion of foreign
objects.
Fan Motor - Permanently lubricated and thermally
protected motor.
Built-in Controls - All units include an automatic
reset thermal cutout that will de-energize the heater
if an overtemperature condition occurs. A manual
reset thermal cutout, in addition to an automatic reset
thermal cutout, is standard on heaters 10 KW and
above. A fan relay is provided to allow the elements
to heat up before fan startup and purges the heater
of residual heat after shutdown. A 24-volt transformer
and disconnecting contactor are provided on most
heaters. Single-phase heaters rated at 5 KW or less
have line voltage controls; 24-volt control and contactor are available. Power fusing is standard on all heaters rated over 48 amps.
Mounting – Universal horizontal or vertical discharge.
Optional diffusers are available for vertical discharge.
An Anemostat diffuser can be used to provide draftfree air movement at lower mounting heights. For
higher mounting heights, radial diffuser with adjustable
fins can be used to increase floor coverage or adjusted for a vertical down blast of air.
29
240 Series
H E A T E R S
Unit Heater
Factory Built-in Options
Code
Consult
Factory
D
F O R C E D - A I R
F
M
P (1)
R1
R2 (1) (2)
S1
S2 (1)
T
V1*
V2
X (2)
Description
Custom KW - CONSULT FACTORY
Power disconnect switch
Fusing under 48 Amps, not available on heaters 3 to
10 KW
Manual Reset Cutout
(In addition to automatic cutout) on heaters up to 10KW
“Heater On” Pilot Light
Built-in 24V transformer and contactor for 3 to 5 KW, single
phase heaters.
120V Transformer to replace 24V Transformer, fused
secondary and grounded
Summer Fan Switch
Summer Fan Switch – Remote Pilot Duty
Built-in Thermostat - 1 - Stage
Built-in Thermostat - 2 - Stage (Option ‘X’ required)
Anemostat (Cone) Diffuser
Radial Diffuser
2-Stage Control
* consult factory for lead times
(1) When specifying Option ‘P’ (pilot light) or Option ‘S2’ (remote fan switch) or
Option ‘R2’ (120V control) with 3 kW to 5 kW single phase heaters, Option
‘R1’ must be also specified.
(2) Option ‘R2’ (120V control) and Option ‘X’ (2-stage control) cannot be combined on heaters rated up to 5 KW.
(3) When specifying these options with 3 to 5 KW single-phase heaters, Option ‘R1’ must also be specified.
(4) When specifying this option, with any heater, option ‘R2’ must also be
specified.
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
1024155
1024156
1024157
1024152
1024153
1024154
1023941
1024059
1024060
1024162
Anemostat (Cone) Diffuser up to 5 kW
Anemostat (Cone) Diffuser over 5 kW up to 20 kW
Anemostat (Cone) Diffuser over 20 kW
Radial Diffuser up to 5 kW
Radial Diffuser over 5 kW up to 20 kW
Radial Diffuser over 20 kW
Horizontal Dust Shield up to 10 kW
Horizontal Dust Shield over 20 kW up to 20 kW
Horizontal Dust Shield over 20 kW
Disconnect Switch, 600V, Three-Pole, 40 Amp
1024163
Disconnect Switch, 600V, Three-Pole, 80 Amp
1024164
1024166
1024167
1024168 (1)(3)
1024169 (2)(4)
1024170
1024171
1024172 (1)(3)
Disconnect Switch, 600V, Three-Pole, 100 Amp
Built-in Thermostat - 1 - Stage
Built-in Thermostat - 2 - Stage (Option ‘X’ required)
Heater On Pilot Light (24V)
Heater On Pilot Light (120V)
Summer Fan Switch - Built-in up to 277V
Summer Fan Switch- Built-in, over 277V
Summer Fan Switch - Remote, 24V Control
Max Mtg.
Height
ft. (m)
A
ft (m)
B
ft (m)
10 (3.0)
15 (4.6)
20 (6.1)
25 (7.6)
17 (5.2)
28 (8.5)
38 (11.6)
68 (20.7)
—
—
—
—
10 (3.0)
15 (4.6)
20 (6.1)
25 (7.6)
22 (6.7)
40 (12.2)
53 (16.2)
85 (25.9)
12 (3.7)
20 (6.1)
27 (8.2)
45
(13.7)
9 (2.7)
13 (4.0)
17 (5.2)
21 (6.4)
17 (5.2)
29 (8.8)
40 (12.2)
68 (20.7)
—
—
—
—
OPEN
up to 5 kW
over 5 up to 10 kW
over 10 up to 20 kW
over 20 up to 50 kW
10 (3.0)
15 (4.6)
20 (6.1)
25 (7.6)
20 (6.1)
30 (9.1)
38 (11.6)
65 (19.8)
—
—
—
—
45°
Vertical Mounting Air Pattern Table
up to 5 kW
over 5 up to 10 kW
over 10 up to 20 kW
over 20 up to 50 kW
9 (2.7)
11 (3.4)
15 (4.5)
18 (5.5)
24 (7.3)
36 (11.0)
46 (14.0)
78 (23.8)
—
—
—
—
Description
WITHOUT DIFFUSER
For a straight downward air pattern,
directional louvers can be removed
in order to maximize airflow.
up to 5 kW
over 5 up to 10 kW
over 10 up to 20 kW
over 20 up to 50 kW
DIRECTIONAL LOUVERS (standard)
Provides a directional (straight line)
airflow which results in a rectangular
air pattern. Louvers can be adjusted
through a 35 degree range of motion
up to 5 kW
over 5 up to 10 kW
over 10 up to 20 kW
over 20 up to 50 kW
ANEMOSTAT DIFFUSER
Ideal for low mounting heights.
Fabricated using 3 diverging hollow
cones which disperse heat to the floor
area at a minimum velocity for comfort.
up to 5 kW
over 5 up to 10 kW
over 10 up to 20 kW
over 20 up to 50 kW
RADIAL DIFFUSER
Ideal for high ceiling mounting.
Louvers can be adjusted to direct
airflow straight down when fully
open to 45 degrees in a radial
pattern which increases floor
coverage by approxiately 20%.
30
Used on
240 Series
Heater Listing
KW
2.5
3.7
3.8
5
6.7
7.5
9.9
10
13.2
13.3
15
19.9
20
25
33.3
37.5
Ph
208
240
277
208
240
277
480
208
240
208
240
277
208
240
480
208
240
277
208
240
208
240
480
208
240
277
208
240
480
277
208
240
208
240
480
208
240
240
277
208
480
208
240
480
208
240
480
208
240
480
1
1
1
1
1
1
3
3
3
1
1
1
3
3
3
1
1
1
1
1
3
3
3
1
1
1
3
3
3
1
1
1
3
3
3
1
3
1
1
3
3
3
3
3
3
3
3
3
3
3
Total
Amps*
12.30
10.7
9.40
16.17
14.05
12.21
4.66
10.85
9.44
24.34
21.13
18.35
14.18
12.33
6.22
32.91
28.62
24.79
36.80
32.00
21.52
18.74
9.39
48.30
42.37
36.70
28.46
24.76
12.40
48.35
64.79
56.27
42.48
36.93
18.44
96.52
48.72
84.18
72.90
56.36
24.46
70.90
61.64
30.77
93.93
81.61
40.75
105.59
91.71
45.80
Approx. Air
Temperature
Rise °F (°C)
27 (15)
27 (15)
46 (26)
37 (21)
49 (27)
52 (29)
60 (33)
49 (27)
61 (34)
2-Stage
Control
Std.
Control
Voltage
Unit
Size
Catalog
Number (2)
1B
1B
1B
1B
1B
1B
1A
1A
1A
1B
1B
1B
1A
1A
1A
1B
1B
1B
1B
1B
1A
1A
1A
1B
1B
1B
1A
1A
1A
1B
Standard
Standard
1B
1B
1B
Standard
1B
Standard
Standard
Standard
1B
Standard
Standard
1B
Standard
Standard
1B
Standard
Standard
1A
208
240
277
208
240
277
24
24
24
208
240
277
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
HX-240-U1025C
HX-240-U1025J
HX-240-U1026N
HX-240-U1033C
HX-240-U1033J
HX-240-U1033N
HX-240-U1037U
HX-240-U1038D
HX-240-U1038K
HX-240-U1050C
HX-240-U1050J
HX-240-U1050N
HX-240-U1050D
HX-240-U1050K
HX-240-U1050U
HX-240-U2067C
HX-240-U2067J
HX-240-U2067N
HX-240-U2075C
HX-240-U2075J
HX-240-U2075D
HX-240-U2075K
HX-240-U2075U
HX-240-U2099C
HX-240-U2100J
HX-240-U2100N
HX-240-U2100D
HX-240-U2100K
HX-240-U2100U
HX-240-U3132N
HX-240-U3133C-X
HX-240-U3133J-X
HX-240-U3150D
HX-240-U3150K
HX-240-U3150U
HX-240-U3199C-X (1)
HX-240-U3199K
HX-240-U3200J-X (1)
HX-240-U3200N-X
HX-240-U3200D-X
HX-240-U3200U
HX-240-U4250D-X
HX-240-U4250K-X
HX-240-U4250U
HX-240-U4333D-X
HX-240-U4333K-X
HX-240-U4333U
HX-240-U4375D-X
HX-240-U4375K-X
HX-240-U4375U
H E A T E R S
3.3
Volts
F O R C E D - A I R
Unit Heater
*Total Amps = Heating element amps and motor amps.
1. Disconnect switch unavailable on HX-240-U3199C-X and HX-240-U3200J-X
2. All Standard heaters are supplied with 24V transformer and contactor except up to 5 KW single phase units. Optional low voltage transformer and contactor are available for these heaters, see Factory Built-in Option ‘R1’.
2-stage heaters can be field wired as single stage.
1A = Optional 2-stage control, unbalanced (option X)
1B = Optional 2-stage control, balanced (option X).
31
240 Series
H E A T E R S
Unit Heater
Remote Thermostat Selection Chart
F O R C E D - A I R
KW
Catalog Number
Volts
Ph
1-Stage
Line
Voltage
HX-240-U1033C
208
1
1007014
1006998 (a)
1007030 (a)
HX-240-U1033J
240
1
1007014
1006998 (a)
1007030 (a)
HX-240-U1033N
277
1
1007014
1006998 (a)
1007030 (a)
HX-240-U1037U
480
3
NA
1006998
1007030
HX-240-U1038D
208
3
NA
1006998
1007030
HX-240-U1038K
240
3
NA
1006998
1007030
HX-240-U1050C
208
1
NA
1006998 (a)
1007030 (a)
HX-240-U1050J
240
1
1007014
1006998 (a)
1007030 (a)
HX-240-U1050N
277
1
1007014
1006998 (a)
1007030 (a)
1006998
1007030
3.3
3.7
3.8
5
All Other 240 Series Heaters
NA
1-Stage
Low
Voltage (b)
2-Stage
Low
Voltage (b)
(a) Add option ‘R1’ for 24V control on these units.
(b) Option ‘R2’ is unavailable with any HEATREX supplied remote low voltage thermostats.
Mounting Brackets
Catalog
Number
Description
1024149
Universal wall & ceiling mounting bracket up to 10 KW
1024150
Universal wall & ceiling mounting bracket over 10 KW up to 20 KW
1024151
Universal wall & ceiling mounting bracket over 20 KW
Finish/Color Options
Code
Color
Unit
Size
CFM
Installed
Weight
lb (kg)
Max. Air
Throw
ft. (m)
Yellow
1
350
25 (11.3)
15 (4.6)
Red
2
650
40 (18.1)
18 (5.5)
3
1500
55 (25)
41 (12.5)
4
3100
155 (70.3)
62 (18.9)
None
Camel
A0
Grey
A1
A2
32
Finish
Airflows, Weights and Air Throw
Polyester
Powder Coat
A3
White
A4
Blue
A5
Steel
(unpainted)
Galvanized
A7
Polyester
Powder Coat
Beige
926 Series
The 926 Series unit heater is designed for industrial and commercial applications.
• Large Capacity: Heavy-duty construction with ratings up to 60 KW at 2,000 CFM.
• Single Point Electrical Hook-up: Heater, fan motor
and controls are all connected to the same branch
circuit. Field connections and built-in controls are
easily accessed in the side-mounted control compartment.
Applications
•Garages
•Vestibules
• Mechanical Rooms
•Warehouses
•Stairwells
•Workshops
• Discharge Direction: The heater may be mounted
horizontally using one of two brackets (supplied) or
vertically using four threaded rods (not included).
H E A T E R S
• C
ontrol Options: Wide range of factory built-in or
field-installed control options to meet job specifications.
F O R C E D - A I R
Unit Heater
Standard Construction Features
Heating Elements – Industrial grade stainless steel
tubular elements in 2-10 KW units and steel finned
tubular elements in 15-60 KW units.
Housing – Cabinet is constructed of 18 and
20-gauge galvanized steel finished with durable
almond polyester powder paint.
Outlet Grille – The outlet grille has individually adjustable louvers to direct airflow. A protective outlet mesh
screen, provided on 2-30 KW heaters, allows for lower
mounting heights.
Fan Motor – Totally enclosed, thermally protected
motor with factory-lubricated ball bearings operates
at 58 dBA (2-10 KW), 67 dBA (15-30 KW) or 77 dBA
(40-60 KW). Blow-through design reduces motor operating temperature for longer life.
Built-in Controls – Include 240/208 volt control circuit (with transformer if necessary), automatic reset
thermal cutout, fan override and factory-installed
contactor. Power fusing is supplied for heaters over
48 amps.
Mounting Bracket – Wall and ceiling bracket provided with each unit under 40 KW for horizontal mounting. 40-60 KW heaters furnished with four corner
support brackets for ceiling mounting.
Installation Requirements – For best performance,
do not install unit heaters above recommended maximum mounting heights of 2-10 KW, 8-feet; 15-30
KW, 10-feet; 40-60 KW, 15-feet. All but 40-60 KW
heaters can be installed at lower mounting heights.
Minimum height for 40-60 KW heaters is 8-feet.
Maximum ambient room temperature for proper
operation is 85°F.
33
926 Series
H E A T E R S
Unit Heater
Factory Built-in Options
Code
F O R C E D - A I R
C
Field-Installed Options
(shipped loose for field installation into heater)
Description
Three Pole Contactor
D1
Disconnect Switch 40 Amp
Catalog
Number
D2
Disconnect Switch 80 Amp
926-124513
Diffuser cone (2-10 kW)
D5
Disconnect Switch 100 Amp
926-124514
Diffuser cone (15-30 kW)
G
Fusing
926-161077
Diffuser cone (40-60 kW)
Description
M
Manual Reset
926-124515
Thermostat Kit
R1
24V Relay
926-124516
24V Relay Kit
R2
24V Relay with Transformer (1)
926-124518
24V Relay Kit with Transformer
T
Thermostat (2)
U
Fan “ON” Switch
V
120V Control, fused secondary and grounded
(1) Add option “R2” when a low voltage remote thermostat is required.
(2) Not available with heater part number 926U10000CA.
Remote Room Thermostat – See page 99
Dimensions, Airflows and Weights
A
B
C
D
E
F
G
H
I
Weight
In. (mm)
In. (mm)
In. (mm)
In. (mm)
In. (mm)
In. (mm)
In. (mm)
In. (mm)
In. (mm)
lb (kg)
2-10
12
(305)
16-1/2
(419)
17
(432)
14-1/16
(357)
11-7/16
(290)
19
(490)
12
(305)
4-7/8
(123)
16-7/8
(428)
45
(20)
15-30
18
(444)
21-7/8
(556)
23
(572)
19
(470)
16
(407)
25
(630)
12
(305)
5-13/16
(148)
23-5/16
(592)
85
(39)
40-60
23
(585)
25
(641)
34
(870)
—
—
36-3/8
(924)
12
(305)
12
(305)
35
(890)
150
(68)
KW
Wall Bracket
4 Threaded Rods
1/2-13 UNC
D
Support Brackets
Ceiling Bracket
E
H
I
B
34
A
G (MIN)
F
C
40-60 KW
926 Series
Heater Listing
KW
2
4
5
7.5
10
CFM
HP
RPM
Voltage
Catalog
Number
HX-926U02000CA
HX-926U02000DA
HX-926U02000JA
HX-926U02000KA
HX-926U02000NA
HX-926U02000TA
HX-926U02000UA
HX-926U03000CA
HX-926U03000DA
HX-926U03000JA
HX-926U03000KA
HX-926U03000NA
HX-926U03000TA
HX-926U04000UA
HX-926U04000CA
HX-926U04000DA
HX-926U04000JA
HX-926U04000KA
HX-926U04000NA
HX-926U04000TA
HX-926U04000UA
HX-926U05000CA
HX-926U05000DA
HX-926U05000JA
HX-926U05000KA
HX-926U05000NA
HX-926U05000TA
HX-926U05000UA
HX-926U07500CA
HX-926U07500DA
HX-926U07500JA
HX-926U07500KA
HX-926U07500NA
HX-926U07500TA
HX-926U07500UA
Volts
Phase
208
208
240
240
277
480
480
208
208
240
240
277
480
480
208
208
240
240
277
480
480
208
208
240
240
277
480
480
208
208
240
240
277
480
480
1
3
1
3
1
1
3
1
3
1
3
1
1
3
1
3
1
3
1
1
3
1
3/1*
1
3/1*
1
1
3
1
3/1*
1
3/1*
1
1
3
10.3
6.3
9.0
5.5
7.9
4.9
3.1
15.1
9.0
13.2
7.9
11.5
7.0
4.3
19.9
11.8
17.4
10.3
15.1
9.0
5.5
24.7
14.6
21.5
12.7
18.8
11.1
6.7
36.8
21.5
32.0
18.7
27.8
16.3
9.7
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
9 (5)
9 (5)
9 (5)
9 (5)
9 (5)
9 (5)
9 (5)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
18 (10)
18 (10)
18 (10)
18 (10)
18 (10)
18 (10)
18 (10)
23 (13)
23 (13)
23 (13)
23 (13)
23 (13)
23 (13)
23 (13)
34 (19)
34 (19)
34 (19)
34 (19)
34 (19)
34 (19)
34 (19)
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1/30
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
1550
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
240/208
208
1
48.8
700
45 (25)
1/30
1550
240/208
HX-926U10000CA
208
240
240
480
480
3
1
3/1*
1
3
28.5
42.4
24.8
21.5
12.7
700
700
700
700
700
45 (25)
45 (25)
45 (25)
45 (25)
45 (25)
1/30
1/30
1/30
1/30
1/30
1550
1550
1550
1550
1550
240/208
240/208
240/208
240/208
240/208
HX-926U10000DA
HX-926U10000JA
HX-926U10000KA
HX-926U10000TA
HX-926U10000UA
H E A T E R S
3
Motor Data
Approximate Air
Temperature Rise
°F (°C)
Total
Amps (1)
F O R C E D - A I R
Unit Heater
(1) Total Amps = Heating element amps and motor amps.
Other voltages available. Consult factory.
Only available with almond finish.
* Can be converted from 3 to 1-phase in the field.
35
926 Series
H E A T E R S
Unit Heater
Heater Listing (cont.)
F O R C E D - A I R
KW
15
20
25
30
40
50
60
Volts
Phase
Total
Amps
(1)
208
208
240
240
480
480
208
208
240
240
480
480
208
208
240
240
480
480
480
480
480
480
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
3
3
3
3
73.2
42.7
63.6
37.2
32.2
18.9
97.3
56.6
84.4
49.2
42.6
25
121.3
70.5
105.3
61.2
53
31
37
49.6
61.6
73.7
CFM
HP
RPM
Voltage
Catalog
Number
1300
1300
1300
1300
1400
1400
1300
1300
1300
1300
1400
1400
1300
1300
1300
1300
1400
1400
1400
2000
2000
2000
36 (20)
36 (20)
36 (20)
36 (20)
34 (19)
34 (19)
49 (27)
49 (27)
49 (27)
49 (27)
45 (25)
45 (25)
61 (34)
61 (34)
61 (34)
61 (34)
56 (31)
56 (31)
68 (38)
64 (18)
80 (27)
96 (36)
1/8
1/8
1/30
1/30
1/6
1/6
1/8
1/8
1/8
1/8
1/6
1/6
1/8
1/8
1/8
1/8
1/6
1/6
1/6
3/4
3/4
3/4
1550
1550
1550
1550
1725
1725
1550
1550
1550
1550
1725
1725
1550
1550
1550
1550
1725
1725
1725
1140
1140
1140
240/208
240/208
240/208
240/208
480 (1 ph)
480 (1 ph)
240/208
240/208
240/208
240/208
480 (1 ph)
480 (1 ph)
240/208
240/208
240/208
240/208
480 (1 ph)
480 (1 ph)
480 (1 ph)
480 (3 ph)
480 (3 ph)
480 (3 ph)
HX-926U15000CA
HX-926U15000DA
HX-926U15000JA
HX-926U15000KA
HX-926U15000TA
HX-926U15000UA
HX-926U20000CA
HX-926U20000DA
HX-926U20000JA
HX-926U20000KA
HX-926U20000TA
HX-926U20000UA
HX-926U25000CA
HX-926U25000DA
HX-926U25000JA
HX-926U25000KA
HX-926U25000TA
HX-926U25000UA
HX-926U30000UA
HX-926U40000UA
HX-926U50000UA
HX-926U60000UA
(1) Total Amps = Heating element amps and motor amps.
Other voltages available. Consult factory.
Only available with almond finish.
36
Motor Data
Approximate Air
Temperature Rise
°F (°C)
924 Series
The 924 Series unit heater is an economical
choice for commercial heating applications.
•C
ompact Design: Ideal for primary or spot heating
applications. Units can be wall or ceiling-mounted
for horizontal airflow.
• Built-in Adjustable Thermostat: Minimum temperature setting on thermostat can be used to disable the
heater.
Applications
• Basements
• Storage Rooms
• Entrances
• Workshops
• Garages
• Service Areas in Air
Handling Units
• Mechanical Rooms
H E A T E R S
•V
ersatility: Three different heater KW ratings can
be field converted to either 240 or 208 single-phase
power.
F O R C E D - A I R
Unit Heater
Standard Construction Features
Heating Elements – Stainless steel tubular elements.
Housing – Cabinets are constructed of 20-gauge galvanized steel with an almond polyester powder paint finish.
Fan/Motor – The fan supplies 300 CFM at 51 dBA.
The motor is permanently lubricated and totally
enclosed.
Outlet Grille – The outlet grille has adjustable louvers to
direct airflow and a protective screen for additional safety.
Built-in Controls – Automatic reset thermal cutout and
adjustable thermostat.
Mounting Bracket – A universal mounting bracket for
either wall or ceiling installation allows for 360° rotation
of the heater.
Dimensions, Airflows and Weights
Approximate Air
Temperature Rise
°F (°C)
Weight
lb (kg)
Catalog
Number
300
21/16 (12/9)
20 (9)
HX-924U02000VA
300
32/24 (18/13)
20 (9)
HX-924U03000VA
300
53/40 (29/22)
20 (9)
HX-924U05000VA
Total
Amps (1)
CFM
1
8.7/7.6
1
12.9/11.2
1
21.2/18/4
Watts
Volts
Phase
2000/1500
240/208
3000/2250
240/208
5000/3750
240/208
(1)Total Amps = Heating element amps and motor amps.
Only available with almond finish.
11"
8"
3-1/2"
15-1/2"
12-1/4"
12"
10-1/2"
37
928 Series
H E A T E R S
Vertical Unit Heater
F O R C E D - A I R
The 928 Series unit heater is designed to heat buildings with high ceilings. It may also be used to recirculate warm air that builds up near ceilings. 928
Series heaters can be used as primary, supplemental
or dual heating systems in commercial or industrial
buildings.
Applications
• Aircraft Hangars
•Malls
•Factories
• Power Generating Stations
•Garages
• Shipping and Receiving Areas
•Gyms
•Warehouses
• Vertical Airflow: Suitable for applications in high
bay industrial buildings where columns, machinery or warehouse stock would obstruct horizontal air
movement.
• Air Distribution Patterns: Three optional air diffusers produce different air distribution patterns to
accommodate various applications.
• High Bay Areas
Standard Construction Features
Heating Elements – Steel finned tubular elements
are grounded for extra safety.
Housing – Cabinet is constructed of 18-gauge galvanized steel with an almond polyester powder paint
finish.
Fan Motor – Quiet, totally enclosed motor is thermally protected.
Factory Built-in Options
Code
Description
Installation Requirements – Do not install heater
closer than 24 inches from walls and ceiling. Mount
heaters out of reach, at least eight feet from the
floor.
Field-Installed Options
(shipped loose for field installation into heater)
D1
Disconnect Switch 40A, 600V, 3-Pole
D2
Disconnect Switch 80A, 600V, 3-Pole
R1
24V Relay
928-124521
Single Cone Diffuser
5-10 KW
R2
24V Relay with Transformer
928-124522
Single Cone Diffuser
15-30 KW
X
120V Control, fused secondary and grounded
928-124523
Triple Cone Diffuser
5-10 KW
928-124524
Triple Cone Diffuser
15-30 KW
928-124525
Jet Cone Diffuser
5-10 KW
928-124526
Jet Cone Diffuser
15-30 KW
928-124527
24V Relay Kit
928-124528
24V Relay Kit with Transformer-208V
928-124529
24V Relay Kit with Transformer-240V
Remote Room Thermostat – See page 99
38
Built-in Controls – Contactor, fan override, terminal
block for remote fan control and linear automatic
reset thermal cutout.
Catalog
Number
Description
Vertical Unit Heater
Air Distribution Patterns
Without Cone
Single Cone
H E A T E R S
H
H
F O R C E D - A I R
928 Series
S
S
Triple Cone
Jet Cone
H
H
S
S
Maximum Mounting Height
Without Cone
KW
Single Cone
Triple Cone
Jet Cone
H
S
H
S
H
S
H
S
Ft (m)
Ft (m)
Ft (m)
Ft (m)
Ft (m)
Ft (m)
Ft (m)
Ft (m)
5-10
12 (4)
19 (6)
8 (3)
22 (7)
10 (3)
31 (10)
16 (5)
20 (6)
15-30
18 (6)
20 (9)
10 (4)
33 (10)
14 (4)
43 (13)
22 (7)
26 (9)
39
928 Series
H E A T E R S
Vertical Unit Heater
F O R C E D - A I R
24"
C
Support Brackets
B
24"
A
B
C
In. (mm)
In. (mm)
In.
(mm)
5-10 KW
23-1/8
(587)
8
(203)
6-15/16
(176)
15-30 KW
30-1/4
(768)
12-3/16
(310)
6-11/16
(170)
Model
(Without Cone)
40
A
928 Series
Heater Listing
Motor Data
CFM
Approx. Air
Temp. Rise
°F (C°)
HP
RPM
Voltage
Volts
Phase
Weight
Ib (kg)
Catalog
Number
3.2
480
3
4.7
450
22 (12)
1/25
1050
4.8
480
3
6.6
450
34 (19)
1/25
1050
208/240
75 (34)
HX-928C03200UA
208/240
75 (34)
HX-928C04800UA
208
1
24.9
450
34 (19)
1/25
208
3
14.7
450
34 (19)
1/25
1050
208/240
75 (34)
HX-928C05000CA
1050
208/240
75 (34)
HX-928C05000DA
240
1
21.7
450
34 (19)
1/25
1050
208/240
75 (34)
HX-928C05000JA
240
3
12.9
450
480
3
8.6
600
34 (19)
1/25
1050
208/240
75 (34)
HX-928C05000KA
34 (19)
1/25
1050
208/240
75 (34)
HX-928C06400UA
208
3
21.7
600
40 (22)
1/25
1050
208/240
75 (34)
HX-928C07500DA
240
1
240
3
32.1
600
40 (22)
1/25
1050
208/240
75 (34)
HX-928C07500JA
18.9
600
40 (22)
1/25
1050
208/240
75 (34)
HX-928C07500KA
480
3
12.5
1200
25 (14)
1/6
1140
208/240
100 (48)
HX-928C09600UA
208
3
28.6
750
41 (23)
1/25
1050
208/240
75 (34)
HX-928C10000DA
240
1
42.5
750
41 (23)
1/25
1050
208/240
75 (34)
HX-928C10000JA
240
3
24.9
750
41 (23)
1/25
1050
208/240
75 (34)
HX-928C10000KA
480
3
16.3
1200
34 (19)
1/6
1140
208/240
100 (48)
HX-928C12800UA
208
3
42.6
1200
40 (22)
1/6
1140
208/240
100 (48)
HX-928C15000DA
240
1
63.4
1200
40 (22)
1/6
1140
208/240
100 (48)
HX-928C15000JA
240
3
37
1200
40 (22)
1/6
1140
208/240
100 (48)
HX-928C15000KA
16
480
3
20.2
1600
32 (18)
1/6
1140
208/240
100 (48)
HX-928C16000UA
19.2
480
3
24
1600
38 (21)
1/6
1140
208/240
100 (48)
HX-928C19200UA
208
3
56.5
1600
40 (22)
1/6
1140
208/240
100 (48)
HX-928C20000DA
240
1
84.2
1600
40 (22)
1/6
1140
208/240
100 (48)
HX-928C20000JA
240
3
49.1
1600
40 (22)
1/6
1140
208/240
100 (48)
HX-928C20000KA
208
3
70.4
2000
40 (22)
1/6
1140
208/240
100 (48)
HX-928C25000DA
240
1
105.0
2000
40 (22)
1/6
1140
208/240
100 (48)
HX-928C25000JA
240
3
61.1
2000
40 (22)
1/6
1140
208/240
100 (48)
HX-928C25000KA
208
3
84.2
2300
41 (23)
1/6
1140
208/240
100 (48)
HX-928C30000DA
240
1
125.9
2300
41 (23)
1/6
1140
208/240
100 (48)
HX-928C30000JA
240
3
73.2
2300
41 (23)
1/6
1140
208/240
100 (48)
HX-928C30000KA
5
6.4
7.5
9.6
10
12.8
15
20
25
30
H E A T E R S
KW
Total
Amps (1)
F O R C E D - A I R
Vertical Unit Heater
(1) Total Amps = Heating element amps and motor amps.
Only available with almond finish.
41
Comparison Chart
H E A T E R S
Wall, Ceiling and Floor Heaters
935
933
F O R C E D - A I R
934
932
940
930
42
Features
Architectural
Wall
933 Series
Commercial
Wall
932 Series
European
Wall
935 Series
Hybrid
Convection
940 Series
Wall
934 Series
Register
Wall
930 Series
Typical
Applications
Entryways
Offices
Reception
areas
Guard houses
Offices
Stairwells
Offices
Restrooms
Offices
Restrooms
Condominiums
Small offices
Storage rooms
Hallways
Stairwells
Wattage Range
up to
8,000
up to
12,000
up to
1,500
up to
2,000
up to 2,000
up to 2,000
Voltages
up to
480/1
up to
480/3
up to
240/1
up to
240/1
up to
240/1
up to
240/1
Airflow CFM
up to 320
up to 480
up to 70
Convection
up to 80
up to 80
Steel
finned
tubular
Steel
finned
tubular
Element Type
Steel
finned
tubular
Steel
finned
tubular
Steel
finned
tubular
Fast
Response
Coil
Element
Standard
Construction
1/8” thick
extruded
aluminum grille
18-gauge
steel grille
20-gauge
steel grille
Cast
Aluminum
grille
20-gauge
steel grille
20-gauge
steel grille
Finish
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Mounting
Surface or
recessed
Surface or
recessed
Surface or
recessed
Surface or
recessed
Surface or
recessed
Surface or
recessed
Custom Colors
Yes
Yes
Yes
Yes
Yes
Yes
Agency
Approvals
CSAus
CSAus
CSAus
CSAus
CSAus
CSAus
Comparison Chart
936
937
922
939
H E A T E R S
931
F O R C E D - A I R
Wall, Ceiling and Floor Heaters
938
Cabinet
922 Series
Fan-Forced
Ceiling
936 Series
Fan Forced
Ceiling
937 Series
Commercial
Ceiling
931 Series
Toe-Space
938 Series
Floor Insert
939 Series
Classrooms
Hallways
Meeting rooms
Classrooms
Day care
Reception areas
Classrooms
Day care
Reception areas
Entryways
Hallways
Restrooms
Kitchens
Reception areas
Under sliding doors
Under windows
up to
24,000
up to
10,000
up to
5,000
up to
8,000
up to
1,000
up to
1,500
up to
480/3
up to 480/3
up to 480/3
up to 480/1
up to 240/1
up to 240/1
up to 1,000
up to 700
up to 450
up to 320
80
80
Steel
finned
tubular
Stainless steel
finned tubular
aluminum fins
Stainless steel
finned tubular
aluminum fins
Steel
finned
tubular
Steel
finned
tubular
Steel
finned
tubular
18-gauge steel
and extruded
aluminum grille
21-gauge
steel grille
21-gauge
steel grille
18-gauge
steel grille
20-gauge
steel grille
20-gauge steel body
and 14-gauge grille
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Polyester
powder
paint
Surface, recessed
or ceiling
Surface or T-bar
Recessed or T-bar
Surface, recessed
or T-bar
Recessed under
cabinet
Recessed in floor
Yes
Yes
Yes
Yes
Yes
Yes
CSAus
CSAus
CSAus
CSAus
CSAus
CSAus
43
933 Series
H E A T E R S
Architectural Wall Heater
F O R C E D - A I R
The 933 Series fan-forced wall heater is designed for
commercial and industrial areas requiring higher KW
ratings and quick recovery. The unit provides a burst
of heat in areas affected by cold drafts or wide temperature swings.
• Efficient Operation: The fan draws air into the top
of the grille and discharges warm air downward to
distribute heat and keep floors warm and dry. High
CFMs create air circulation within the room to provide uniform temperatures.
• E xtended Capacity: The 933 Series is available
with one or two modules and ratings up to 8,000 W
and 320 CFM.
Applications
•Entryways
•Restrooms
•Garages
•Stairwells
• Guard Houses
•Vestibules
•Offices
• Reception Areas
Standard Construction Features
Heating Elements – Steel finned tubular elements.
Outlet Grille – The WAI has an architectural extruded aluminum grille in a choice of eight polyester
powder paint finishes. The closely spaced, heavy
bar grille design prevents insertion of foreign objects.
The tamperproof thermostat adjustment is concealed
behind the front cover.
Built-in Controls – Automatic reset thermal cutout,
fan override and tamperproof thermostat (32° to
120°F).
44
Fan Motor – Permanently lubricated, totally
enclosed fan operates at a low 58 dBA.
Installation Requirements – Standard supply wiring rated at 60°C can be used for installation of wall
heaters. Heater must be installed at least ten inches
from the floor and adjacent walls.
Rough in Dimensions –
• 1500/1125 - 4800 Watt heaters: 14-1/2” wide x
19-7/8” high x 4-1/2” deep.
• 6000/4500 - 8000 Watt heaters: 30-3/16” wide x
19-7/8” high x 4-1/2” deep.
933 Series
Field-Installed Options
Factory Built-in Options
Code
(shipped loose for field installation into heater)
Description
Catalog
Number
Description
Disconnect Switch 600V, Three-pole, 40 Amp
D3
Disconnect Switch 277V, Double-pole, 20 Amp
933-124501
Surface Mounting Box (1500-4800 W)
R1
24 Relay (1)
933-158471
Surface Mounting Box (6000-8000 W)
R2
24V Relay with Transformer (1)
933-151114
1” Semi Recessed Trim Kit (1500-4800 W)
Fan On/Auto Switch
933-166530
1” Semi Recessed Trim Kit (6000-8000 W)
933-151115
2” Semi Recessed Trim Kit (1500-4800 W)
933-166531
2” Semi Recessed Trim Kit (6000-8000 W)
S3
(1) A built-in thermostat will not be supplied when option R1 or R2 are
selected. Consult the factory if built-in thermostat is required with these
options.
Add color code to end of catalog number. (See next page for codes.)
Required Wall Depth Opening
4-5/16"
H E A T E R S
D1
F O R C E D - A I R
Architectural Wall Heater
Remote Room Thermostat – See page 99
4-3/16"
23"
6,000 - 8,000 Watts
Side View
22-3/4"
Heater Dimensions
-
1,500 - 4,800 Watts
31-7/8"
Double Unit
-
K.O. 7/8”
-
-
-
-
-
-
Grille Dimensions
Side View
Front View
(Without Grille)
45
933 Series
H E A T E R S
Architectural Wall Heater
Heater Listing
F O R C E D - A I R
Built-in tamperproof thermostat is included.
Watts
Volts
(1 Phase)
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
oF (oC)
Weight
lb (kg)
Catalog Number
1500/1125
240/208
6.6/5.8
160
30/27 (17/12)
24 (11)
HX-933U01500V¶
1500
120
12.9
160
30 (17)
28 (13)
HX-933U01500B¶
277
5.8
160
30 (17)
28 (13)
HX-933U01500N¶
1500
480
3.5
160
30 (17)
28 (13)
HX-933U01500T¶
240/208
8.7/7.6
160
40/30 (22/17)
24 (11)
HX-933U02000V¶
208
10.0
160
40 (22)
24 (11)
HX-933U02000C¶
277
7.6
160
40 (22)
28 (13)
HX-933U02000N¶
480
4.5
160
40 (22)
28 (13)
HX-933U02000T¶
240/208
12.9/11.2
160
60/45 (33/25)
24 (11)
HX-933U03000V¶
277
11.2
160
60 (33)
28 (13)
HX-933U03000N¶
480
6.6
160
60 (33)
28 (13)
HX-933U03000T¶
240/208
17.0/14.8
160
80/60 (44/33)
24 (11)
HX-933U04000V¶
208
19.6
160
80 (44)
24 (11)
HX-933U04000C¶
4000
277
14.8
160
80 (44)
28 (13)
HX-933U04000N¶
480
8.7
160
80 (44)
28 (13)
HX-933U04000T¶
4800/3600
240/208
20.4/17.7
160
96/72 (53/40)
24 (11)
HX-933U04800V¶
208
23.5
160
96 (53)
28 (13)
HX-933U04800C¶
277
17.7
160
96 (53)
28 (13)
HX-933U04800N¶
480
10.4
160
96 (53)
28 (13)
HX-933U04800T¶
240/208
25.4/22.0
320
60/45 (33/25)
50 (23)
HX-933U06000V¶
277
22.1
320
60 (33)
50 (23)
HX-933U06000N¶
480
12.9
320
60 (33)
50 (23)
HX-933U06000T¶
240/208
33.7/29.2
320
80/60 (44/33)
50 (23)
HX-933U08000V¶
208
38.9
320
80 (44)
50 (23)
HX-933U08000C¶
277
29.3
320
80 (44)
50 (23)
HX-933U08000N¶
480
17.1
320
80 (44)
50 (23)
HX-933U08000T¶
2000/1500
2000
3000/2250
3000
4000/3000
4800
6000/4500
6000
8000/6000
8000
(1) Total Amps = Heating element amps and motor amps.
All models listed are single-phase.
¶Add color code to end of catalog number.
Standard colors. See Color Code Chart below.
Color Code Chart
Code
46
Color
Code
Color
BZ
Bronze
BG
Beige-Grey
AE
Metallic Silver
W
White
CM
Metallic Charcoal
A
Almond
NR
Textured Black
AL
Aluminum
932 Series
H E A T E R S
The 932 Series fan-forced wall heater is designed
for commercial and industrial areas requiring higher
KW ratings and quick recovery. The unit provides
a burst of heat in areas affected by cold drafts or
wide temperature swings.
• Efficient Operation: The fan draws air into the
top of the grille and discharges warm air downward to distribute heat and keep floors warm
and dry. High CFM’s create air circulation within
the room to provide uniform temperatures.
• Extended Capacity: The 932 Series is available
with one, two or three modules and ratings up to
12,000 W at 480 CFM.
F O R C E D - A I R
Commercial Wall Heater
Applications
•Entryways
•Restrooms
•Garages
•Stairwells
• Guard Houses
•Vestibules
•Offices
• Reception Areas
Standard Construction Features
Heating Elements – Steel finned tubular elements.
Outlet Grille – The 932 Series has an 18-gauge steel
grille with rounded corners and a polyester powder
paint finish in white or almond. The external thermostat adjustment knob can be replaced with the concealing plug provided for tamperproof construction.
Built-in Controls – Automatic reset thermal cutout,
fan override and thermostat (32° to 120°F).
Fan Motor – Permanently lubricated, totally
enclosed fan operates at a low 58 dBA.
Installation Requirements – Standard supply wiring rated at 60°C can be used for installation of wall
heaters. Heater must be installed at least ten inches
from the floor and adjacent walls.
Rough in Dimensions –
• 1500/1125 - 4800 Watt heaters: 14-1/2” wide x
19-7/8” high x 4-1/2” deep.
• 6000/4500 - 8000 Watt heaters: 30-3/16” wide x
19-7/8” high x 4-1/2” deep.
• 12000/9000 - 12000 Watt heaters: 46-5/8” wide x
19-7/8” high x 4-1/2” deep.
47
932 Series
H E A T E R S
Commercial Wall Heater
Field-Installed Options
Factory Built-in Options
F O R C E D - A I R
Code
(shipped loose for field installation into heater)
Description
Catalog
Number
D1
Disconnect Switch 600V, Three-pole, 40 Amp
D2
Disconnect Switch, 600V, Three-pole 80 Amp
D3
Disconnect Switch 277V, Double-pole, 20 Amp
R1
24 Relay (1)
R2
24V Relay with Transformer (1)
S3
Fan On/Auto Switch
(1) A built-in thermostat will not be supplied when option R1 or R2 are
selected. Consult the factory if built-in thermostat is required with these
options.
Remote Room Thermostat – See page 99
Required Wall Depth Opening
4-5/16"
4-3/16"
Description
932-124500
Surface Mounting Box (1500-4800 W)
932-158211
Surface Mounting Box (6000-8000 W)
932-158212
Surface Mounting Box (12000 W)
932-146878
1” Semi Recessed Trim Kit (1500-4800 W)
932-166532
1” Semi Recessed Trim Kit (6000-8000 W)
932-166534
1” Semi Recessed Trim Kit (12000 W)
932-153670
2” Semi Recessed Trim Kit (1500-4800 W)
932-166533
2” Semi Recessed Trim Kit (6000-8000 W)
932-166535
2” Semi Recessed Trim Kit (12000 W)
Standard colors - Add W for white finish or A for almond finish to the
end of catalog number.
Special or custom colors - See inside back cover for color codes to be added
to end of catalog number.
23"
Side View
Grille Dimensions
1,500 - 4,800 Watts
6,000 - 8,000 Watts
16-1/8"
31-7/8"
12,000 Watts
48-5/16"
22-1/16"
1-5/16"
14-7/16"
8-5/16" 2"
Side View
30-3/1
6"
2-7/8"
2-3/16"
1-5/16"
2"
Top View
2"
1-5/16"
19-7/8"
Side View
48
Front View
(Without Grille)
K.O. 7/
46-5/8"
932 Series
Heater Listing
Adjustable thermostat is included. A hole plug is provided for tamperproof installations.
Volts
Phase
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
oF (oC)
Weight
lbs (kg)
Catalog
Number
1500/1125
240/208
1
6.6/5.8
160
30/22 (17/12)
24 (11)
HX-932U01500V¶
120
1
12.9
160
30 (17)
28 (13)
HX-932U01500B¶
1500
277
1
5.8
160
30 (17)
28 (13)
HX-932U01500N¶
480
1
3.5
160
30 (17)
28 (13)
HX-932U01500T¶
2000/1500
240/208
1
8.7/7.6
160
40/30 (22/17)
24 (11)
HX-932U02000V¶
208
1
10.0
160
40 (22)
24 (11)
HX-932U02000C¶
277
1
7.6
160
40 (22)
28 (13)
HX-932U02000N¶
480
1
4.6
160
40 (22)
28 (13)
HX-932U02000T¶
240/208
1
12.9/11.2
160
60/45 (33/25)
24 (11)
HX-932U03000V¶
2000
3000/2250
277
1
11.2
160
60 (33)
28 (13)
HX-932U03000N¶
480
1
6.7
160
60 (33)
28 (13)
HX-932U03000T¶
4000/3000
240/208
1
17.0/14.8
160
80/60 (44/33)
24 (11)
HX-932U04000V¶
208
1
19.6
160
80 (44)
24 (11)
HX-932U04000C¶
4000
277
1
14.8
160
80 (44)
28 (13)
HX-932U04000N¶
480
1
8.7
160
80 (44)
28 (13)
HX-932U04000T¶
4800/3600
240/208
1
20.4/17.7
160
96/72 (53/40)
24 (11)
HX-932U04800V¶
208
1
23.5
160
96 (53)
28 (13)
HX-932U04800C¶
3000
4800
6000/4500
277
1
17.7
160
96 (53)
28 (13)
HX-932U04800N¶
480
1
10.4
160
96 (53)
28 (13)
HX-932U04800T¶
240/208
1
25.4/22.0
320
60/45 (33/25)
50 (23)
HX-932U06000V¶
277
1
22.1
320
60 (33)
50 (23)
HX-932U06000N¶
480
1
12.9
320
60 (33)
50 (23)
HX-932U06000T¶
8000/6000
240/208
1
33.7/29.2
320
80/60 (44/33)
50 (23)
HX-932U08000V¶
208
1
38.9
320
80 (44)
50 (23)
HX-932U08000C¶
8000
277
1
29.3
320
80 (44)
50 (23)
HX-932U08000N¶
480
1
17.1
320
80 (44)
50 (23)
HX-932U08000T¶
12000/9000
240/208
3(2)
28.9/25.0
480
80 (44)
90 (41)
HX-932U12000P¶
208
3
33.7
480
80 (44)
90 (41)
HX-932U12000D¶
6000
12000
240
3
29.3
480
80 (44)
90 (41)
HX-932U12000K¶
277
1
43.7
480
80 (44)
90 (41)
HX-932U12000N¶
480
1
25.4
480
80 (44)
90 (41)
HX-932U12000T¶
480
3
14.8
480
80 (44)
90 (41)
HX-932U12000U¶
H E A T E R S
Watts
F O R C E D - A I R
Commercial Wall Heater
(1) Total Amps = Heating element amps and motor amps.
(2) Single-phase is available upon request, consult factory
All models listed are single-phase unless otherwise specified. Other voltages available. Consult factory.
¶Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
49
935 Series
F O R C E D - A I R
H E A T E R S
European Style Wall Heater
The 935 Series wall heater has a stylish, contemporary
design with rounded corners and soft lines for an elegant
appearance. This heater is ideal for areas with space
restrictions and high heating requirements.
• U
nique Element Design: Stitched ribbon-type heating
element provides instant heat for areas that need to
be warmed quickly.
• T hree Models: The standard single-stage heater is
controlled by an optional remote line-voltage thermostat. Heater type T has a two-stage thermostat which
automatically switches from minimum to maximum
wattages as needed. Heater type TZ is furnished
with an additional 0-60 minute mechanical timer that
provides manual operation at maximum wattage during occupied periods, then resumes normal two-stage
control.
• Installation Flexibility: The heater can be recessed
in a 2-inch by 3-inch stud wall or surface mounted
without the use of adapters.
(Shown with optional thermostat & timer)
Applications
•Entryways
•Offices
• Fire Station Changing
Areas
• Reception Areas
•Restrooms
Standard Construction Features
Heating Elements – Stitched ribbon-type element.
Fan Motor – Two-speed whisper-quiet squirrel-cage
fan operates at 33 dBA with 35 CFM and 42.5 dBA
with 70 CFM.
Outlet Grille – The 20-gauge steel grille has a polyester powder paint finish available in white, almond,
black or optional stainless steel front cover.
Installation Requirements – The air outlet should be
installed a minimum of 12-inches above vinyl floors.
Built-in Controls – Automatic reset thermal cutout
prevents overheating.
Rough In Dimensions – All heaters: 11-5/8” wide x
15-1/2” high x 2” deep.
16-1/2”
3"
14-7/8”
2"
2"
4-5/16"
4”
6-15/16"
16-1/2"
K.O. 7/8"
2”
▲
▲
K.O. 1/4"
▲
1-1/2"
4"
13-3/16"
3/4"
Remote Room Thermostat – See page 99
Heater Listing
Watts
50
Wall-Mounted
Recessed
K.O. 7/8"
1-5/8"
CFM
Minimum
Maximum
Volts
(1 Phase)
Total
Amps (1)
Minimum
Maximum
Maximum Air
Temperature
Weight
lb (kg)
Catalog
Number
-
1500
120
13.0
-
70
68 (38)
14 (6)
HX-935U01500B
750
1500
120
13.0
35
70
68 (38)
14 (6)
HX- 935U01500B-T
750
1500
120
13.0
35
70
68 (38)
14 (6)
HX- 935U01500B-TZ
-
1500/1125
240/208
6.7/5.9
-
70
68/51 (38/28)
14 (6)
HX-935U01500V
750/563
1500/1125
240/208
6.7/5.9
35
70
68/51 (38/28)
14 (6)
HX-935U01500V-T
750/563
1500/1125
240/208
6.7/5.9
35
70
68/51 (38/28)
14 (6)
HX-935U01500V-TZ
(1) Total Amps = Heating element amps and motor amps.
Add W to end of catalog number for white finish, A for almond, BK for black or SS for custom stainless steel front cover.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
940 Series
The 940 Series wall heater is a unique design and offers two levels
of heating. The first level is convection heat with a second level
of forced-air heating. This feature combines the quiet operation of
convection heating for normal heating conditions and when needed
a boost to forced-air heating with greater heating capacity, all in the
same unit. This is well suited for condominiums when an up scale
appearance is required.
• Manual Power Boost: To override the automatic temperature
control the heater can be easily switched into the boost heat level
using the built-in timer. Boost power can be set for 5, 10, 15, 20,
25 or 30 minutes.
Applications
•Entryways
•Offices
• Fire Station Changing
Areas
• Reception Areas
H E A T E R S
• Unique Temperature Control: Built-in digital thermostat with full
modulating power for convection to fan-forced heating. The power
level is automatically managed by the thermostat through the full
output of the heater. The electronic thermostat displays actual
room temperature, with adjustable temperature settings between
50 and 95°F (10 to 35°C). When the heater is on, four graduated
lines indicate the power level on the display.
F O R C E D - A I R
Hybrid Convection Wall Heater
• Mounting: The heater can be recessed in a 2-inch by 3-inch stud
wall, surface mounted or surface mounted with a color matched
•Restrooms
surface mounting box.
Standard Construction Features
Heating Elements – Instant heat nickel-chrome coil resistant wire element.
Fan motor – Whisper-quiet squirrel-cage fan with factorylubricated motor.
Outlet Grille – Heavy cast aluminum front cover with steel
bar inlet and outlet grilles has a polyester powder paint finish available in white or almond.
Installation Requirements – Do not install heater
covered with vinyl. Maintain a minimum of 4-inches (102
mm) clearance below heater, 1-inch (25 mm) to adjacent
walls and 48-inches (1219 mm) in front of heater.
Built-in Controls – Digital display electronic thermostat with
timer, automatic reset thermal cutout, temperature sensor
and LED night light with on-off switch.
KOE Ø 22 mm
KOE Ø 7/8"
550 mm
21 5/8"
140 mm
5 1/2"
70 mm
2 3/4"
15 mm
9/16"KOE Ø 6.4 mm
KOE Ø 1/4"
42 mm
1 5/8"
KOE Ø 22 mm
KOE Ø 7/8"
20 mm
3/4"
369 mm
14 1/2"
332 mm
13 1/16"
38 mm
1 1/2"
350 mm
13 3/4"
Front view
Rough In Dimensions – All heaters: 18-5/8” wide x
13-3/8” high x 2-3/4” deep.
Side view
Heater Listing
380 mm
15"
550 mm
21 5/8"
470 mm
18 1/2"
337 mm
13-1/4"
Bottom view
Recessed
W all-mounte
Factory Built-in Options
Watts
Volts
(1 Ph)
Amps
Weight
lb (kg)
Catalog
Number
1500
120
12.5
22.8 (10.3)
HX-940U01500B
2000
240
8.3
22.8 (10.3)
HX-940U02000J
Standard colors – Add W for white finish or A for almond finish to the end
of catalog number.
Special or custom colors – See inside of back cover for color codes to be
added to end of catalog number.
Code
D3
Description
Disconnect Switch, 277V, Double-pole, 20 Amp
Field-Installed Options
Catalog
Number
940-213895
Description
Cast Aluminum Surface Mounting Box
Standard colors – Add W for white finish or A for almond finish to the end
of catalog number.
Special or custom colors – See inside of back cover for color codes to be
added to end of catalog number.
51
934 Series
F O R C E D - A I R
H E A T E R S
Wall Heater
The 934 Series wall heater is designed for
recessed mounting into shallow 2-inch by 3-inch
stud walls. It provides heat in a quiet, efficient
manner. Single units can heat small areas and
multiple heaters can be used in large or oddshaped rooms.
• M
ounting Options: Units can be surface (with
optional box) or recessed mounted, vertically or
horizontally, in one of four positions. A tapered
recess box assures a tight fit when mounted into
the wall.
Applications
•Breezeways
•Entryways
•Restrooms
• Small Offices
• Storage Rooms
Standard Construction Features
Heating Elements – Steel finned tubular elements.
Outlet Grille – The louvered front grille is made from
22-gauge steel with rounded corners. The grille is finished with a polyester powder paint in white or almond.
1,000 W and 41.3 dBA at 80 CFM for all models
rated above 1,000 W.
Built-in Controls – Automatic reset thermal cutout.
Installation Requirements - The air outlet should
be installed a minimum of ten inches above vinyl
floors.
Fan Motor – Quiet, permanently lubricated axial
fan operates at 38 dBA at 40 CFM for models up to
Rough In Dimensions – All heaters: 7-3/16” wide
x 14-1/8” high x 3” deep.
Factory Built-in Options
Code
Description
D3
Disconnect Switch, 277V, Double-pole, 20 Amp
T1
Tamperproof Thermostat, Single-pole, 17 Amp
T2
Tamperproof Thermostat, Double-pole, 17 Amp
T5
Adjustable Thermostat, Single-pole, 17 Amp
T6
Adjustable Thermostat, Double-pole, 17 Amp
Double-pole thermostats include positive off feature.
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
934-124647
Surface Mounting Box
934-124648
Adjustable Thermostat Kit, Single-pole, 17 Amp
934-124649
TamperproofThermostatKit,Single-pole,17Amp
934-124650
AdjustableThermostat Kit, Double-pole, 17 Amp
934-124651
TamperproofThermostatKit,Double-pole,17Amp
Standard colors - Add W for white finish or A for almond finish to
the end of catalog number.
Remote Room Thermostat – See page 99
52
Special or custom colors - See inside back cover for color codes to be
added to end of catalog number.
934 Series
Optional Surface Mounting
Surface Box
Mounting Positions
Heater
7-3/16”
2” x 3” Stud Wall
7-1/16”
Grille
8-1/8”
16”
3"
3”
3”
3"
13-7/8”
14-1/8”
H E A T E R S
8-5/32”
Wall Opening
F O R C E D - A I R
Wall Heater
16”
Heater Dimensions
Heater Listing
Watts
Volts
(1 Phase)
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
°F (°C)
Weight
lb (kg)
Catalog
Number
500
120
4.6
40
40 (22)
9 (4)
HX-934U00500B
500/375
240/208
2.3/2.0
40
40/30 (22/17)
9 (4)
HX-934U00500V
750
120
6.7
40
60 (33)
9 (4)
HX-934U00750B
750/563
240/208
3.3/2.9
40
60/45 (33/25)
9 (4)
HX-934U00750V
1000
120
8.7
40
80 (44)
9 (4)
HX-934U01000B
1000/750
240/208
4.5/3.8
40
80/60 (44/33)
9 (4)
HX-934U01000V
1250
120
10.8
80
50 (28)
9 (4)
HX-934U01250B
1250/938
240/208
5.4/4.7
80
50/37 (28/21)
9 (4)
HX-934U01250V
1500
120
12.9
80
60 (33)
9 (4)
HX-934U01500B
1500/1125
240/208
6.5/5.6
80
60/45 (33/25)
9 (4)
HX-934U01500V
2000/1500
240/208
8.5/7.4
80
80/60 (44/33)
9 (4)
HX-934U02000V
2000
208
9.8
80
80 (44)
9 (4)
HX-934U02000C
(1) Total Amps = Heating element amps and motor amps.
Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
53
930 Series
F O R C E D - A I R
H E A T E R S
Register Wall Heater
(Shown with optional built-in thermostat)
Applications
The 930 Series register wall heater is ideal for
use as a primary heat source in small areas or as
supplemental heat in more spacious areas. Multiple
heaters can be used to effectively heat large or oddshaped rooms.
• Installation Options: Units are designed for
recessed mounting into shallow 2-inch by 3-inch
stud walls or surface mounting with the use of an
optional box.
• Safety: Finned tubular elements provide electrical isolation from accidental contact.
• T emperature Control: An optional thermostat
can be field installed in the heater or a remote
thermostat can be used.
•Hallways
•Restrooms
•Stairwells
Standard Construction Features
Heating Elements – Steel finned tubular elements.
Outlet Grille – The louvered front grille is made from
20-gauge steel. The grille is finished with polyester
powder paint in white or almond.
41.3 dBA at 80 CFM for all models rated above
1,000 W.
Built-in Controls – Automatic reset thermal cutout.
Installation Requirements – The air outlet should
be installed a minimum of ten inches above vinyl
floors.
Fan Motor – Quiet, factory lubricated fan operates
at 38 dBA at 40 CFM for models up to 1,000 W and
Rough In Dimensions – All heaters: 14-1/8” wide x
7-3/16” high x 3” deep.
Factory Built-in Options
Code
Description
D3
Disconnect Switch, 277V, Double-pole, 20 Amp
T1
Tamperproof Thermostat, Single-pole, 17 Amp
T2
Tamperproof Thermostat, Double-pole, 17 Amp
T5
Adjustable Thermostat, Single-pole, 17 Amp
T6
Adjustable Thermostat, Double-pole, 17 Amp
Double-pole thermostats include positive off feature.
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
930-166766
Surface Mounting Box
930-166767
AdjustableThermostat Kit, Single-pole, 17 Amp
930-166768
TamperproofThermostatKit,Single-pole,17Amp
930-166769
AdjustableThermostatKit,Double-pole,17Amp
930-166770
TamperproofThermostatKit,Double-pole,17Amp
Standard colors - Add W for white finish or A for almond finish to
the end of catalog number.
Remote Room Thermostat – See page 99
54
Special or custom colors - See inside back cover for color codes to be
added to end of catalog number.
930 Series
Wall-Mounted
3"
Optional Surface
Mounting
3"
14-1/8"
Wall
Opening
H E A T E R S
16"
Surface
Box
Heater
13-7/8"
7-3/16"
F O R C E D - A I R
Register Wall Heater
8-1/8"
8-1/8"
3"
Grille
7-1/16"
16"
Heater Dimensions
Heater Listing
Watts
Volts
(1 Phase)
Total
Amps (1)
CFM
500
500/375
750
750/563
1000
1000/750
1250
1250/938
1500
1500/1125
2000
2000/1500
120
240/208
120
240/208
120
240/208
120
240/208
120
240/208
208
240/208
4.6
2.3/2.0
6.7
3.3/2.9
8.7
4.5/3.8
10.8
5.4/4.7
12.9
6.5/5.6
9.8
8.5/7.4
40
40
40
40
40
40
80
80
80
80
80
80
Approximate
Air Temperature
Rise °F (°C)
40 (22)
40/30 (22/17)
60 (33)
60/45 (33/25)
80 (44)
80/60 (44/33)
50 (28)
50/37 (28/21)
60 (33)
60/45 (33/25)
80 (44)
80/60 (44/33)
Weight
lb (kg)
Catalog
Number
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
9 (4)
HX-930U00500B
HX-930U00500V
HX-930U00750B
HX-930U00750V
HX-930U01000B
HX-930U01000V
HX-930U01250B
HX-930U01250V
HX-930U01500B
HX-930U01500V
HX-930U02000C
HX-930U02000V
(1) Total Amps = Heating element amps and motor amps.
Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
55
922 Series
F O R C E D - A I R
H E A T E R S
Cabinet Unit Heater
The 922 Series cabinet heater offers a unique combination of quality, efficiency, reliability and flexibility.
The attractive cabinet design blends into any commercial decor.
• M
ounting Options: The cabinet heater can be
mounted on the floor, wall or ceiling. It can also
be recessed into the wall or ceiling as required.
Twelve air inlet and outlet combinations are available.
• Simplified Maintenance: The insulated front panel
is hinged to allow for easy access.
• Quiet Operation: The blower wheel is mounted
directly on the motor shaft to reduce the noise level.
• Fresh Air Inlet: Manual or optional power-operated inlet allows fresh air to enter through the rear of
the heater and mix with re-circulated room air.
Applications
•Classrooms
•Stairways
•Hallways
•Corridors
• Meeting Rooms
• Waiting Rooms
•Lobbies
• Entry Ways
Standard Construction Features
Heating Elements – Industrial grade steel finned tubular elements.
Housing – Cabinet is constructed of 18-gauge steel
with an polyester powder paint finish in white or
almond.
Outlet Grille – An extruded architectural style aluminum grille discourages tampering with the heating element. The grille can be field converted for front or top air
discharge.
Built-in Controls – Automatic reset thermal cutout and
fan delay. Power fusing is supplied for heaters over
48 amps.
56
Fan Motor – The squirrel cage fan is beltless and
two-speed, operating at 48 dBA at low speed and 50
dBA at high speed. Fan motors have permanently
lubricated sleeve bearings for trouble-free service.
Installation Requirements – For best performance,
do not install cabinet heaters above recommended
maximum mounting height of ten feet.
Rough In Dimensions – Recess mounting only:
Heater Length + 1” wide x 27” high x 12 deep.
922 Series
Factory Built-in Options
Code
Field-Installed Options
(shipped loose for field installation into heater)
Description
A1
Fresh Air Inlet (1)
A2
Power Operated Fresh Air Inlet (1)
D1
Disconnect Switch 600V, Three-pole, 40 Amp
D2
Disconnect Switch 600V, Three-pole, 80 Amp
922-124530
G
Fusing
922-124531
M
Manual Reset
922-124532
N1
2-Speed Motor w/High-Low Switch (2)
922-124533
80 (2032)
N2
2-Speed Motor w/High-Low Relay-24 (1) (2) (3)
922-124534
28 (711)
R1
24V Relay
922-124535
R2
24V Relay with Transformer
922-124536
Catalog
Number
28 (711)
922-124537
Smooth Finish on Heater Back
48 (1219)
922-124538P
Heater Length - In. (mm)
66 (1677)
922-124539P
80 (2032)
922-124540P
S1
On/Auto Fan Relay-24V
922-124541P
S2
24V On/Standby Heating Relay with Transformer
922-124538
S3
On/Auto Fan Switch
922-124539
S4
On/Standby Heating Switch
922-124540
T1
Tamperproof Thermostat, 1-Stage, Single-pole
922-124541
Tamperproof Thermostat, 2-Stage (4)
922-218265
T7
922-218266
(1) Do not install built-in thermostat with these options.
922-218267
(2) To obtain the minimum ratings, it is necessary to add the optional “N1”
two-speed motor with high/low switch for manual operation or option “N2”
two-speed motor with high/low relay-24 Volt. The “N2” can be connected
to a remote two-stage, wall-mounted thermostat or field-furnished low voltage device for maximum/minimum control.
922-218268
Top 922-224750
Air Discharge
48 (1219)
Sub Base
66 (1676)
48 (1219)
Recess Trim Kit
66 (1676)
80 (2032)
28 (711)
Permanent/Washable
48 (1219)
Air Filters
66 (1676)
(Wall Installation Only)
80 (2032)
28 (711)
Replaceable Throwaway
48 (1219)
Air Filters
66 (1676)
(Wall Installation Only)
80 (2032)
Smooth Finish on Heater
Back Kit
28 (711)
48 (1219)
66 (1676)
Heater Length In (mm)
80 (2032)
Tamperproof single-pole thermostat kit
Special or custom colors - See inside back cover for color codes to be
B1
C1
added to end of A1
part number.
Remote Room Thermostat – See page 99
D1
Bottom Air Discharge
Mounting Applications
A2
B2
C2
D2
A3
B3
C3
D3
Ceiling
Top Air Discharge
B1
C1
D1
Ceiling
Bottom Air Discharge
A2
B2
C2
D2
A3
B3
C3
D3
Ceiling
Ceiling
28 (711)
Standard colors - Add W for white finish or A for almond finish to
the end of part number.
(3) Option N2 is required for two-stage remote thermostat operation.
(4) When choosing Option T7; A1, A2, N1, N2, R1, R2 & T1 are unavailable.
A1
Heater
Length
In. (mm)
Description
H E A T E R S
S
F O R C E D - A I R
Cabinet Unit Heater
Wall
Semi-recessed
Recessed
D3 type mounting only
Wall
Recessed
Semi-recessed
D1 or D2 type mounting only
57
922 Series
H E A T E R S
Cabinet Unit Heater
K.O.1-3/4 -1-3/8"
WWall
allOpening
penin
O g
F O R C E D - A I R
27"
K.O.1-1/
8 -7/8"
26"
Front
View
FrontVie
w
2-1/1
6"
Length + 1"
Bottom
View
Bottom
View
Max.
Min.
2000
1333
3000
1000
4000
2667
5000
3333
6000
4000
208
208
240
240
277
480
208
208
240
240
277
480
208
208
240
240
277
480
208
208
240
240
277
480
208
208
240
240
277
480
K.O.1/4"
Surface
Installation
2”
10”
2-1/2"
Maximum recommended installation height: 10 feet.
7-3/8"
Total Amps (2)
CFM
Max.
Min.
Max.
Min
11.0
7.0
9.7
6.2
8.6
3.8
15.8
9.7
13.9
8.6
12.2
5.0
20.6
12.5
18.1
11.0
15.8
6.2
25.4
15.3
22.2
13.4
19.4
7.4
30.2
18.1
26.4
15.8
23.1
8.6
7.8
5.1
7.0
2.6
6.2
3.0
6.2
4.2
5.6
3.8
5.0
2.6
14.2
8.8
12.5
7.8
11.0
4.6
17.4
10.7
15.3
9.5
13.4
5.4
20.6
12.5
18.1
11.0
15.8
6.2
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
Semi-Recessed
2"
Heater Listing
Volts Phase
Recessed
1-1/2"
3-5/16"
6-3/16"
Watts (1)
Installation With Recess Trim Kit
Installation
2"
With A
Sub Base
Approximate Air Heater Length
Temp. Rise °F (°C)
In. (mm)
26 (14)
26 (14)
26 (14)
26 (14)
26 (14)
26 (14)
38 (21)
38 (21)
38 (21)
38 (21)
38 (21)
38 (21)
51 (28)
51 (28)
51 (28)
51 (28)
51 (28)
51 (28)
64 (36)
64 (36)
64.(36)
64 (36)
64 (36)
64 (36)
77 (43)
77 (43)
77 (43)
77 (43)
77 (43)
77 (43)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
28 (711)
Weight
Lbs (kg)
Catalog
Number
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
115 (52)
HX-922U02000C
HX-922U02000D
HX-922U02000J
HX-922U02000K
HX-922U02000N
HX-922U02000U
HX-922U03000C
HX-922U03000D
HX-922U03000J
HX-922U03000K
HX-922U03000N
HX-922U03000U
HX-922U04000C
HX-922U04000D
HX-922U04000J
HX-922U04000K
HX-922U04000N
HX-922U04000U
HX-922U05000C
HX-922U05000D
HX-922U05000J
HX-922U05000K
HX-922U05000N
HX-922U05000U
HX-922U06000C
HX-922U06000D
HX-922U06000J
HX-922U06000J
HX-922U06000N
HX-922U06000U
(1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” twospeed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device
for maximum/minimum control.
(2) Total Amps = Heating element amps and motor amps.
Other voltages available. Consult factory.
Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
Specify mounting application code when ordering (see page 57).
58
922 Series
Heater Listing (continued)
Watts (1)
Max.
Min.
Volts Phase
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
3
1
3
1
3
3
1
3
1
3
3
3
1
3
3
CFM
Max.
Min.
Max.
Min
41.3
25.0
36.1
22.1
31.7
12.4
50.9
30.6
44.5
26.9
38.9
14.8
60.5
36.1
52.8
31.7
46.1
17.3
76.3
45.9
66.7
40.3
22.3
90.7
54.2
79.2
47.5
25.9
101.8
61.1
88.9
53.7
29.7
72.2
105.6
63.3
34.5
22.0
13.9
19.5
12.4
17.2
7.6
26.8
16.7
23.6
14.8
20.9
8.8
31.6
19.5
27.8
17.3
24.8
10.0
52.3
32.0
45.9
28.3
16.2
61.9
37.5
54.2
33.1
18.6
69.7
42.6
61.2
37.7
21.7
50.1
72.3
44.1
24.9
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
750
750
750
750
750
750
750
750
750
750
1000
1000
1000
1000
1000
1000
1000
1000
1000
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
600
600
600
600
600
600
600
600
600
600
800
800
800
800
800
800
800
800
800
Approximate Air Heater Length
Temp. Rise °F (°C)
In. (mm)
51 (28)
51 (28)
51 (28)
51 (28)
51 (28)
51 (28)
64 (36)
64 (36)
64 (36)
64 (36)
64 (36)
64 (36)
77 (43)
77 (43)
77 (43)
77 (43)
77 (43)
77 (43)
63 (35)
63 (35)
63 (35)
63 (35)
63 (35)
77 (43)
77 (43)
77 (43)
77 (43)
77 (43)
64 (36)
64 (36)
64 (36)
64 (36)
64 (36)
77 (43)
77 (43)
77 (43)
77 (43)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
66 (1677)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
80 (2032)
Weight
Lbs (kg)
Catalog
Number
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
146 (66)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
210 (96)
240 (109)
240 (109)
240 (109)
240 (109)
240 (109)
240 (109)
240 (109)
240 (109)
240 (109)
HX-922U08000C
HX-922U08000D
HX-922U08000J
HX-922U08000K
HX-922U08000N
HX-922U08000U
HX-922U10000C
HX-922U10000D
HX-922U10000J
HX-922U10000K
HX-922U10000N
HX-922U10000U
HX-922U12000C
HX-922U12000D
HX-922U12000J
HX-922U12000K
HX-922U12000N
HX-922U12000U
HX-922U15000C
HX-922U15000D
HX-922U15000J
HX-922U15000K
HX-922U15000U
HX-922U18000C
HX-922U18000D
HX-922U18000J
HX-922U18000K
HX-922U18000U
HX-922U20000C
HX-922U20000D
HX-922U20000J
HX-922U20000K
HX-922U20000U
HX-922U24000D
HX-922U24000J
HX-922U24000K
HX-922U24000U
H E A T E R S
208
208
240
8000 4000
240
277
480
208
208
240
10000 5000
240
277
480
208
208
240
12000 6000
240
277
480
208
208
15000 10000 240
240
480
208
208
18000 12000 240
240
480
208
208
20000 13333 240
240
480
208
240
24000 16000
240
480
Total Amps (2)
F O R C E D - A I R
Cabinet Unit Heater
(1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” twospeed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device
for maximum/ minimum control.
(2) Total Amps = Heating element amps and motor amps.
Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
Specify mounting application code when ordering (see page 57).
59
936/937 Series
F O R C E D - A I R
H E A T E R S
Fan-Forced Ceiling Heater
936 Series Surface
Mounting
937 Series Recessed Mounting
Applications
Downward Discharge
Uniform Circulation
The 936/937 ceiling heaters are designed for commercial applications. 936 Series heaters are designed for
surface mounting and most can be adapted for T-Bar
installation with an optional kit. The 937 Series heater
is designed for recessed mounting and installation into
2-feet by 2-feet ceiling grids. The 937 Series comes
with a built-in flange; an additional trim ring kit is not
required.
• Enhanced Performance: These heaters set new
industry standards with ratings up to 10,000 W and
700 CFM in single and three-phase 208, 240 and
480 voltages.
• Increased Comfort: The side draw-through inlet
with down discharge promotes circulation within
the space for uniform temperatures and increased
comfort.
• Classrooms
• Offices
• Day Care
• Reception Areas
• Entryways
• Restrooms
• Guard Houses
• Vestibules
• Hallways
• Workshops
• Lobbies
Standard Construction Features
Heating Elements – Stainless steel tubular elements
with aluminum fins.
Outlet Grille – The grille is made of 20-gauge galvanized steel and is finished with a polyester powder
paint in white or almond.
Built-in Controls – Automatic reset thermal cutout and
fan delay relay.
Fan Motor – Quiet, direct drive aluminum fan and
totally enclosed motor with lifetime lubricated ball
bearings.
Installation Requirements – For best performance,
ceiling heaters should be installed between 8 and
12-feet above the floor.
Rough In Dimensions – 937 Series Only: 23” wide
x 23” high x 6” deep.
Factory Built-in Options
Code
60
Description
D1
Disconnect Switch 600V, Three-pole, 40 Amp
D2
Disconnect Switch 600V, Three-pole, 80 Amp
D3
Disconnect Switch 277V, Double-pole, 20 Amp
R1
24V Control Relay
R2
24V Control Relay with Transformer
S3
Summer Fan Switch and Pilot Light
S5
Summer Fan 24V Relay for Remote Switching
and Pilot Light (Switch not included)
S6
Summer Fan 240V Relay for Remote Switching
and Pilot Light (Switch not included)
T1
Tamperproof Thermostat
X
120V Control, fused secondary and grounded
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
936-158478
Tamperproof Thermostat Kit
936-158479
T-Bar Adaptor for CDI surface mounting
2000 through 5000 watt heaters only
936-218269
24V Control Relay Kit
Add W to end of catalog number for white finish or add A for almond
finish.
Remote Room Thermostat – See page 99
936/937 Series
K.O.
1-1/8 7/8"
K.O. 1/4"
2-3/4"
1-7/8"
2-1/2"
1-9/16"
K.O.
1-1/8/ 7/8"
K.O.1/4
5-11/16"
5"
5-5/8"
4-3/4"
22-5/8"
1-3/16"
2-1/1
6-1/2"
16-3/8"
936 Series
2,000-5,000 Watt
Surface Mounting
1-7/8
1-9/16"
6-1/2"
7-15/16"
6-1/2"
7-15/16"
23-7/8"
22-5/16"
23-7/8"
16-3/8"
937 Series
2,000-5,000 Watt
Recessed Mounting
K.O.1/4
2-3/4"
2-1/2"
H E A T E R S
7-5/16"
K.O.
1-1/8/ 7/8
F O R C E D - A I R
Fan-Forced Ceiling Heater
22-5/16"
936 Series
7,500-10,000 Watt
Surface Mounting
1
Hanger
Clips
936 Series Surface Mounting
for 7,500 to 10,000
Watt Heaters
2
937 Series Recessed
Mounting
936 Series Surface Mounting
for 2,000 to 5,000 Watt Heaters
61
936/937 Series
H E A T E R S
Fan-Forced Ceiling Heater
Surface Mounting Heater Listing
F O R C E D - A I R
Watts
2000
3000
4000
5000
7500
9900
10000
Volts
Phase
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
°F (°C)
Weight
lb (kg)
Catalog
Number
208
208
240
240
277
480
480
208
208
240
240
277
480
480
208
208
240
240
277
480
480
208
208
240
240
277
480
480
1
3
1
3
1
1
3
1
3
1
3
1
1
3
1
3
1
3
1
1
3
1
3
1
3
1
1
3
10.3
6.3
9.0
5.5
7.9
4.9
3.1
15.1
9.0
13.2
7.9
11.5
7.0
4.3
19.9
11.8
17.4
10.3
15.1
9.0
5.5
24.7
14.6
21.5
12.7
18.8
11.1
6.7
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
14 (8)
21 (12)
21 (12)
21 (12)
21 (12)
21 (12)
21 (12)
21 (12)
28 (16)
28 (16)
28 (16)
28 (16)
28 (16)
28 (16)
28 (16)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
35 (19)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
25 (11.3)
HX-936U02000C¶
HX-936U02000D¶
HX-936U02000J¶
HX-936U02000K¶
HX-936U02000N¶
HX-936U02000T¶
HX-936U02000U¶
HX-936U03000C¶
HX-936U03000D¶
HX-936U03000J¶
HX-936U03000K¶
HX-936U03000N¶
HX-936U03000T¶
HX-936U03000U¶
HX-936U04000C¶
HX-936U04000D¶
HX-936U04000J¶
HX-936U04000K¶
HX-936U04000N¶
HX-936U04000T¶
HX-936U04000U¶
HX-936U05000C¶
HX-936U05000D¶
HX-936U05000J¶
HX-936U05000K¶
HX-936U05000N¶
HX-936U05000T¶
HX-936U05000U¶
208
1
36.8
700
34 (19)
34 (15.4)
HX-936U07500C¶
208
240
240
277
480
480
208
208
240
240
277
480
480
3
1
3
1
1
3
1
3
1
3
1
1
3
21.5
32.0
18.7
27.8
16.3
9.7
48.0
28.0
42.4
24.8
36.8
21.5
12.7
700
700
700
700
700
700
700
700
700
700
700
700
700
34 (19)
34 (19)
34 (19)
34 (19)
34 (19)
34 (19)
46 (26)
46 (26)
46 (26)
46 (26)
46 (26)
46 (26)
46 (26)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
34 (15.4)
HX-936U07500D¶
HX-936U07500J¶
HX-936U07500K¶
HX-936U07500N¶
HX-936U07500T¶
HX-936U07500U¶
HX-936U09900C¶
HX-936U09900D¶
HX-936U10000J¶
HX-936U10000K¶
HX-936U10000N¶
HX-936U10000T¶
HX-936U10000U¶
(1) Total Amps = Heating element amps and motor amps.
¶Add W to end of catalog number for white finish or add A for almond finish.
Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number.
62
936/937 Series
Recessed Mounting Heater Listing
Watts
3000
4000
5000
Phase
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
°F (°C)
Weight
lb (kg)
Catalog
Number
208
1
10.3
450
14 (8)
31 (14)
HX-937U02000C¶
208
3
6.3
450
14 (8)
31 (14)
HX-937U02000D¶
240
1
9.0
450
14 (8)
31 (14)
HX-937U02000J¶
240
3
5.5
450
14 (8)
31 (14)
HX-937U02000K¶
277
1
7.9
450
14 (8)
31 (14)
HX-937U02000N¶
480
1
4.9
450
14 (8)
31 (14)
HX-937U02000T¶
480
3
3.1
450
14 (8)
31 (14)
HX-937U02000U¶
208
1
15.1
450
21 (12)
31 (14)
HX-937U03000C¶
208
3
9.0
450
21 (12)
31 (14)
HX-937U03000D¶
240
1
13.2
450
21 (12)
31 (14)
HX-937U03000J¶
240
3
7.9
450
21 (12)
31 (14)
HX-937U03000K¶
277
1
11.5
450
21 (12)
31 (14)
HX-937U03000N¶
480
1
7.0
450
21 (12)
31 (14)
HX-937U03000T¶
480
3
4.3
450
21 (12)
31 (14)
HX-937U03000U¶
208
1
19.9
450
28 (16)
31 (14)
HX-937U04000C¶
208
3
11.8
450
28 (16)
31 (14)
HX-937U04000D¶
240
1
17.4
450
28 (16)
31 (14)
HX-937U04000J¶
240
3
10.3
450
28 (16)
31 (14)
HX-937U04000K¶
277
1
15.1
450
28 (16)
31 (14)
HX-937U04000N¶
480
1
9.0
450
28 (16)
31 (14)
HX-937U04000T¶
480
3
5.5
450
28 (16)
31 (14)
HX-937U04000U¶
208
1
24.7
450
35 (19)
31 (14)
HX-937U05000C¶
208
3
14.6
450
35 (19)
31 (14)
HX-937U05000D¶
240
1
21.5
450
35 (19)
31 (14)
HX-937U05000J¶
240
3
12.7
450
35 (19)
31 (14)
HX-937U05000K¶
277
1
18.8
450
35 (19)
31 (14)
HX-937U05000N¶
480
1
11.1
450
35 (19)
31 (14)
HX-937U05000T¶
480
3
6.7
450
35 (19)
31 (14)
HX-937U05000U¶
H E A T E R S
2000
Volts
F O R C E D - A I R
Fan-Forced Ceiling Heater
(1) Total Amps = Heating element amps and motor amps.
¶Add W to end of catalog number for white finish or add A for almond finish.
Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number.
63
931 Series
F O R C E D - A I R
H E A T E R S
Commercial Ceiling Heater
Applications
•Entryways
•Restrooms
•Garages
•Stairwells
•Hallways
•Vestibules
The 931 Series ceiling heater is designed for commercial use in areas where no wall space is available. It
provides supplemental heat to prevent cold drafts or
wide temperature swings.
• E xtended Capacity: Heaters are available as single
or double modules with ratings up to 8,000 W and 320
CFM in 480 volt single-phase.
• C
ontrol Options: Heaters can be controlled by a
building management system with the addition of a
low voltage relay.
• F lexible Mounting: Units can be surface, (with
optional surface mounting box) recessed or installed in
T-Bar ceiling systems.
Standard Construction Features
Heating Elements – Steel finned tubular elements.
Fan Motor – Permanently lubricated, open and ventilated
fan.
Outlet Grille – The louvered front grille is made of
18-gauge steel with rounded corners. The grille is
finished with a polyester powder paint in white or
almond.
Installation Requirements – For best performance, do
not install ceiling heaters above recommended maximum
mounting height of ten feet. Heater must be installed at
least ten inches from adjacent walls.
Built-in Controls – Automatic reset thermal cutout, fan override and 240 volt standard control,
with contactor when required.
Rough In Dimensions –
• 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8”
high x 4-1/2” deep.
• 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8”
high x 4-1/2” deep.
Factory Built-in Options
Code
Description
D1
Disconnect Switch 600V, Three-pole, 40 Amp
D3
Disconnect Switch 277V, Double-pole, 20 Amp
R1
24V Control Relay
R2
24V Control Relay with Transformer
T1
Built-in Tamperproof Thermostat
T2
Adjustable Thermostat
Remote Room Thermostat – See page 99
Standard colors - Add W for white finish or A for almond finish
to the end of catalog number.
64
Special or custom colors - See inside back cover for color codes to
be added to end of catalog number.
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
931-124506
931-158213
931-124507
931-124508
931-124509
931-124510
931-124511
931-124512
931-124513
931-218272
931-218273
Description
Surface Mounting Box (1500-4800W)
Surface Mounting Box (6000-8000W)
Thermostat Kit
24V Control Relay Kit
24V Control Relay with Transformer, 208V Kit
24V Control Relay with Transformer, 240V Kit
24V Control Relay with Transformer, 277V Kit
T-Bar Adapter 23-3/4” x 23-3/4” (1500-4000W)
T-Bar Adapter 23-3/4” x 23-3/4” (6000-8000W)
Extruded Aluminum Front Grille (1500-4000W)
Extruded Aluminum Front Grille (6000-8000W)
Mounting Box for Aluminum Front Grille
931-218274 Surface
(1500-4800W)
Mounting Box for Aluminum Front Grille
931-218275 Surface
(6000-8000W)
931 Series
Heater Listing
Watts
1500/1125
1500
2000
3000/2250
3000
4000/3000
4000
6000/4500
6000
8000/6000
8000
Total
Amps (1)
CFM
240/208
277
480
240/208
277
480
240/208
277
480
240/208
208
277
480
240/208
277
480
240/208
208
277
480
6.6/5.8
5.8
3.5
8.7/7.6
7.6
4.5
12.9/11.2
11.2
6.6
17.0/14.8
19.6
14.8
8.7
25.4/22.0
22.1
12.9
33.7/29.2
38.9
29.3
17.1
160
160
160
160
160
160
160
160
160
160
160
160
160
320
320
320
320
320
320
320
Approximate
Air Temperature
Rise °F (°C)
30/27 (17/12)
30 (17)
30 (17)
40/30 (22/17)
40 (22)
40 (22)
60/45 (33/25)
60 (33)
60 (33)
80/60 (44/33)
80 (44)
80 (44)
80 (44)
60/45 (33/25)
60 (33)
60 (33)
80/60 (44/33)
80 (44)
80 (44)
80 (44)
Weight
lb (kg)
Catalog
Number
20 (9)
26 (12)
26 (12)
20 (9)
26 (12)
26 (12)
20 (9)
26 (12)
26 (12)
20 (9)
20 (9)
26 (12)
26 (12)
40 (18)
52 (24)
52 (24)
40 (18)
40 (18)
52 (24)
52 (24)
HX-931U01500V
HX-931U01500N
HX-931U01500T
HX-931U02000V
HX-931U02000N
HX-931U02000T
HX-931U03000V
HX-931U03000N
HX-931U03000T
HX-931U04000V
HX-931U04000C
HX-931U04000N
HX-931U04000T
HX-931U06000V
HX-931U06000N
HX-931U06000T
HX-931U08000V
HX-931U08000C
HX-931U08000N
HX-931U08000T
H E A T E R S
2000/1500
Volts
(1 Phase)
F O R C E D - A I R
Commercial Ceiling Heater
(1) Total Amps includes motor amps.
Standard colors - Add W for white finish or A for almond finish to the end of catalog number.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
6,000 - 8,000 Watts
1,500 - 4,000 Watts
-
-
"
-
"
"
- -
Required wall
depth opening
109 mm
4 5/16"
-
-
109 mm
4 5/16"
"
561 mm
22 1/16"
-
Side view
All models
-
-
"
-
"
"
- -
"
"
"
-
"
"
"
"
65
938 Series
H E A T E R S
Fan-Forced Toe-Space Heater
The 938 Series heater is designed for installation in places
where other heaters do not fit. These heaters can be installed
into the toe space or kick space below a cabinet, in the soffit
above a cabinet or into risers of a stairway.
F O R C E D - A I R
• Multiple Wattage: Quick disconnect lead wires allow output conversion from 1,000 to 500 watts.
• Overtemperature Protection: Automatic reset thermal
cutout is provided for primary overtemperature protection.
More convenient than thermal fuses, which require field
replacement when overtemperature conditions occur.
Applications
• Checkout Counters
• Reception Areas
•Kitchens
•Ticket/Tollbooths
• T wo-piece Construction: Unit is designed for easy installation. The fan, motor and controls are factory assembled
into a sheet metal box with a removable front grille.
Standard Construction Features
Heating Elements – Steel finned tubular elements
provide durability.
Fan Motor – Factory-lubricated fan motor operates
at 44.5 dBA with 80 CFM.
Outlet Grille – Heavy 20-gauge steel grille has a
polyester powder paint finish. Standard grille colors
include black, white or almond.
Soffit Adapter – Included with the heater.
Built-in Controls – Heater comes complete with a
bi-metal automatic reset thermal cutout and warning
light to indicate when the heater is running excessively hot.
Rough In Dimensions – All heaters: 20-1/2” wide x
3-27/32” high x 10-1/2” deep.
Factory Built-in Options
Code
Adjustable thermostat, single-pole
T6
Adjustable thermostat, double-pole
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
T5
Installation Requirements – Do not install heater on
or above vinyl flooring.
Description
938-158480
Adjustable thermostat kit, single-pole
938-218240
Adjustable thermostat kit, double-pole
20-1/4"
4"
MAX
3 27/32"
Floor
Wall Opening
10 1/2"
20 1/2"
4"
3-11/16"
21-3/4"
10- 1/8"
Heater Listing
Watts
Volts
1000/500
500/375
1000/750
120
240/208
Total
Amps (1)
CFM
8.8/4.6
2.5/2.3
4.6/4.1
80
80
80
Approximate
Air Temperature
Rise °F (°C)
20 (11)
20/15 (11/8)
40/30 (22/17)
(1) Total Amps = Heating element amps and motor amps.
Add W to end of catalog number for white finish, A for almond, or BK for black.
66
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
Weight
lb (kg)
Catalog
Number
13 (6)
13 (6)
13 (6)
HX-938U01000B
HX-938U01000V
939 Series
F O R C E D - A I R
Fan-Forced Floor Heater
H E A T E R S
The 939 Series floor heater is compact to fit into tight
spaces. It is designed to mount between the floor joists.
• U
nique Design: The heater features a separate
housing and core assembly. The core assembly is
completely prewired with leads and an electrical connection plug, which can be removed for service and
cleaning without disturbing the housing or field wiring.
• Safety Screen: A protective screen prevents foreign
objects from falling onto the heating elements or interfering with the fan.
Applications
•Entryways
• Small Rooms
• Open Stairwells
• Under Large Window Areas
Standard Construction Features
Heating Elements – Steel finned tubular elements
provide durability.
Fan Motor – Quiet, factory-lubricated fan motor operates at 39.5 dBA with 80 CFM.
Housing – Heavy welded 20-gauge steel housing.
Installation Requirements – Floor heaters should
be installed a minimum of six inches from adjacent
walls.
Outlet Grille – The 14-gauge steel grille has a polyester powder paint finish. Standard grille colors
include bronze, white or almond.
Built-in Controls – Manual reset thermal cutout
prevents overheating.
Rough In Dimensions – All heaters: 14-3/8” wide x
7-7/16” high x 8” deep.
Heater Listing
Watts
Volts
Total
Amps (1)
CFM
Approximate Air
Temperature Rise
°F (°C)
Weight
lb (kg)
Catalog
Number
500
120
4.6
80
20 (11)
16 (7.3)
HX-939U00500B
1000
120
8.8
80
40 (22)
16 (7.3)
HX-939U01000B
1500
120
13.0
80
60 (33)
16 (7.3)
HX-939U01500B
100/750
240/208
4.6/4.1
80
40/30 (22/17)
16 (7.3)
HX-939U01000V
1500/1125 240/208
6.7/5.9
80
60/45 (33/25)
16 (7.3)
HX-939U01500V
(1) Total Amps = Heating element amps and motor amps.
Add W to end of catalog number for white finish, A for almond, or BZ for bronze.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
Remote Room Thermostat – See page 99
8"
14-1/4"
7-1/4"
67
COMPARISON CHART
Baseboard and Convector Heaters
907
H E A T E R S
914
903
B A R R I E R
906
D R A F T
A N D
C O N V E C T O R
B A S E B O A R D
68
911
916
908
Architectural
Industrial
Architectural
Architectural
Sill-Height
Sill-Height
Cabinet
Convector
Convector
Convector
Convector
908/909Series
904/906Series 905/907Series
911/912Series
Mini Draft
Barrier
914 Series
High Watt
Density Draft
Barrier
916 Series
Features
Baseboard
903 Series
Typical
Applications
Retail stores,
Small offices
Commercial
buildings,
Public buildings
Industrial
buildings,
Institutions
Wattage
Range
300 to 2,500
200 to 2,500
200 to 2,500
800 to 4,000
1,000 to 6,000
300 to 1,400
375 to 4,000
Watt Density
W/ft (W/m)
275 (900)
200 (650)
275 (900)
200 (650)
150 (490)
100 (330)
275 (900)
200 (650)
150 (490)
100 (330)
500 (1640)
375 (1250)
1,000 (3,280)
750 (2,450)
500 (1,640)
175 (574)
150 (490)
500 (1,640)
355 (1,165)
250 (820)
175 (575)
Voltages
120 - 277
(1 Ph)
120 - 277
(1 Ph)
120 - 277
(1 Ph)
208 - 277
(1 Ph)
208 - 277 (1 Ph)
208 - 480 (3 Ph)
208 - 480
(1 Ph)
208 - 480
(1 Ph)
Banks, Offices
Classrooms,
Entryways,
Classrooms,
Entryways, HallConference
Hallways,
Conference
ways, Schools
rooms, Hallways
Shoppingcenters
rooms
Element Type
Stainless
Stainless
Stainless
Stainless
Stainless
Stainless
Stainless
steel with
steel with
steel with
steel with
steel with
steel with
steel with
aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins
Standard
Construction
20-gaugesteel
18-gauge
18-gauge
20-gaugesteel
18-gaugesteel
cabinetry,
steelcabinetry
22-gaugesteel steelcabinetry
cabinetry with 16-gaugesteel cabinetry with
with14-gauge
bodyandfront with14-gauge
16-gaugesteel frontcoverand 16-gaugesteel
aluminumfront
aluminumfront
panel
front cover
extruded
front cover
and top covers
cover
aluminumgrille
18-gauge
steelcabinetry
with14-gauge
aluminumfront
and top covers
Finish
Polyester
powder paint
Polyester
powder paint
Polyester
powder paint
Polyester
powder paint
Polyester
powder paint
Polyester
powder paint
Polyester
powder paint
Sloped-Top
Version
No
904 Series
905 Series
908 Series
911 Series
No
No
Bottom Air
Inlet Option
No
Yes
Yes
No
No
Standard
Standard
Pedestal Kit
Option
No
Yes
Yes
Yes
Yes
Yes
Yes
Front Warm
Air Outlet
Option
No
No
No
No
No
Custom
Colors
Yes
Yes
Agency
Approvals
CSAUS
CSAUS
Yes
Yes
(909 Series only)
(912SeriesOnly)
Yes
Yes
Yes
Yes
Yes
CSAUS
CSAUS
CSAUS
CSAUS
CSAUS
903 Series
•Offices
•Restrooms
•Retail Stores
•Restaurants
H E A T E R S
Applications
The 903 Series baseboard heater is more compact than any other
heater on the market, yet it provides a high level of performance
and strength. The unit’s trim design enhances its appearance and
rounded corners eliminate the sharp edges found on square heaters.
• E asy to Install: Heaters may be mounted flush on any floor surface. Two rows of oblong mounting holes with center mark for
ease of installation. No disassembly installation with single-screw
built-in rear entry wire holder.
• E lectric Receptacles: Units can be furnished with built-on 120 and
240-volt receptacles to provide access for other electrical appliances.
• C
ontrol Options: Heaters can be controlled by a building management system with the addition of a low voltage relay. Adding a
proportional control device provides precise temperature control
and increased energy savings.
B A S E B O A R D
Baseboard Heater
Standard Construction Features
Heating Elements – Stainless steel elements with aluminum fins
float on high temperature nylon bushings for quiet operation.
Built-in Controls – Linear limit, automatic reset
thermal cutout.
Housing – Robust 22-gauge steel body with 20-gauge front panel
and welded junction box, with 4H pencil hardness epoxy/polyester
powder paint finish in white or almond.
69
903 Series
Baseboard Heater
Field-Installed Options
H E A T E R S
Factory Built-in Options
B A S E B O A R D
Code
(shipped loose for field installation into heater)
Description
D3
Disconnect Switch, 277V, Double-pole, 20 Amp
M1
High Altitude Automatic Cutout
R1
24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp
R7
Triac Proportional Relay, 277V Max, 2500 W Max
T1
Tamperproof Thermostat, Single-pole, 277V, 25 Amp
T2
Tamperproof Thermostat, Double-pole, 277V, 25 Amp
with off position
T5
Adjustable Thermostat, Single-pole, 277V, 25 Amp
T6
Adjustable Thermostat, Double-pole, 277V, 25 Amp
with off position
62 mm
2-7/16"
64.5 mm
2-9/16"
KOE �22M
KOE �7/8"
148 mm
5-13/16"
34 mm
1-3/8"
75 mm
2-15/16"
Side View
Catalog
Number
Description
903-243496‡
Baseboard Section 6 in. (152 mm) - 240V Splitter
Box to permanently connect an air conditioner
(20A switch, double-pole, double-throw)
903-243497‡
Baseboard Section 6” (152mm) - 240V Splitter Box
toward a surface mount, 6-20R Receptacle, 20A
switch, double-pole, double throw
903-243498‡
Baseboard Section 6” (152mm) - Surface mounted
duplex 5-15R receptable, 120V, 15A
903-243499‡
Baseboard Section 6” (152mm) - Surface mounted
duplex 6-20R receptable, 240V
903-243500‡
Baseboard Section 6” (152mm) - for the installation of a 24V relay (relay not included)
903-243501
Electronic Relay Kit, single-pole, coil 24V, with
transformer, 15A 277 max
903-243502
Electronic Relay Kit, single-pole, coil 24V, without
transformer, 15A 277 max
903-243503
Relay Kit 24V with transformer, 120V, 25 Amp
(2-wire only)
903-243504
Relay Kit 24V with Transformer, 208V, 22 Amp
903-243505
Relay Kit 24V with Transformer, 240V, 22 Amp
903-243506
Relay Kit 24V with Transformer, 277V, 19 Amp
903-243507
Relay Kit 24V without Transformer, 120V - 240V,
22 Amp, 277V, 19 Amps
903-243509‡
Thermostat Kit, Adjustable, Double-pole, 277V, 25
Amp with off position
903-243510‡
Thermostat Kit, Adjustable, Single-pole, 277V, 25
Amp
903-243511‡
Thermostat Kit, Tamperproof, Double-pole, 277V,
25 Amp with off position
903-243512‡
Thermostat Kit, Tamperproof, Single-pole, 277V, 25
Amp
903-243513‡
Touch Up Brush Paint (1/2 oz)
903-243514‡
Touch Up Spray Paint (6 oz)
903-243515‡
Universal Corners (inside and outside)
Standard colors - Add W for white finish or A for almond finish to the end of part
number.
Special or custom colors - See inside back cover for color codes to be added to end of
part number.
70
903 Series
Heater Listing
How to order: Heater Code with color code + Options (example HX-903U00750BW-T1)
Standard Watt Density Models 275 W/ft. (900 W/m)
Heater Code
Dual Voltage Heater Code
Watts
120V
(1 Ph)
Amps
208V
(1 Ph)
Amps
277V
(1 Ph)
Amps
Watts at
240/208V
22.75
(577)
300
HX-903U00300B‡
2.5
HX-903U00300C‡
1.4
—
1.1
300/225
HX-903U00300V‡ 1.3/1.1
4.5
(2.0)
27.75
(702)
500
HX-903U00500B‡
4.2
HX-903U00500C‡
2.4
HX-903U00500N‡
1.8
500/375
HX-903U00500V‡ 2.1/1.8
5.5
(2.5)
37.75
(956)
750
HX-903U00750B‡
6.3
HX-903U00750C‡
3.6
HX-903U00750N‡
2.7
750/563
HX-903U00750V‡ 3.1/2.7
7.3
(3.3)
48
(1217)
1000
HX-903U01000B‡
8.3
HX-903U01000C‡
4.8
HX-903U01000N‡
3.6
1000/750 HX-903U01000V‡ 4.2/3.6
9.0
(4.0)
60
(1524)
1250
HX-903U01250B‡
10.4
HX-903U01250C‡
6.0
HX-903U01250N‡
4.5
1250/938 HX-903U01250V‡ 5.2/4.5
10.5
(4.8)
72
(1829)
1500
HX-903U01500B‡
12.5
HX-903U01500C‡
7.2
HX-903U01500N‡
5.4
1500/1125 HX-903U01500V‡ 6.3/5.4
12.0
(5.5)
75.5
(1916)
1750
—
—
HX-903U01750C‡
8.4
HX-903U01750N‡
6.3
1750/1313 HX-903U01750V‡ 7.3/6.3
13.5
(6.2)
96
(2439)
2000
—
—
HX-903U02000C‡
9.6
HX-903U02000N‡
7.2
2000/1500 HX-903U02000V‡ 8.3/7.2
15.0
(6.8)
93
(2364)
*2250
—
—
HX-903U02250C‡ 10.8 HX-903U02250N‡
8.1
*2250/1688 HX-903U02250V‡ 9.4/8.1
16.5
(7.5)
102.25
(2596)
*2500
—
—
HX-903U02500C‡ 12.0 HX-903U02500N‡
9.0
*2500/1875 HX-903U02500V‡ 10.4/9.0
18.0
(8.2)
240/208V
(1 Ph)
Amps
Weight
Lbs (kg)
H E A T E R S
Length
In. (mm)
B A S E B O A R D
Baseboard Heater
Other single-phase voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to the catalog number where ‡ is indicated.
(*) These items must be ordered in pairs to reduce shipping damage.
16.8 mm
11/16"
89.5 mm
3-1/2"
KOE �22mm
KOE �7/8"
Bottom View
KOE �6.2 mm
KOE �1/4"
89.5 mm
3-1/2"
72.8 mm
2-7/8"
89.5 mm
3-1/2"
24.1 mm
1"
75 mm
2-15/16"
89.5 mm KOE � 22mm
KOE � 7/8"
3-1/2"
25.4 mm
1"
25.1 mm
1"
71
904/906 Series
C O N V E C T O R S
Architectural Sill-Height Convector
Architectural Sloped Top Sill-Height Convector
906
904
Applications
• Air, Rail or Bus Terminals
•Hallways
•Auditoriums
•Lobbies
•Corridors
•Offices
•Entryways
•Foyers
The 904/906 Series architectural sill-height convector
(also known as draft barriers) are designed to fit under
large windows to prevent cold down drafts. These
heaters can provide total or supplemental heating for a
variety of applications.
• Installation Options: Units may be mounted to
the wall flush on the floor or on pedestals. Custom
lengths, blank sections and inside or outside corners
are available for wall-to-wall installations. Units can
be ordered with smooth painted finish when the back
of the heater is visible.
• Added Safety: The sloped-top of the 904 Series
prevents objects from being set on top of the heater,
which can restrict airflow and cause overheating.
• Choice of Colors: Heaters can be matched to any
décor. White or almond is standard and a wide range
of optional colors and custom finishes including anodized aluminum are available.
Standard Construction Features
Heating Elements – Stainless steel elements with
aluminum fins float on high temperature nylon bushings
for quiet operation.
Housing – Cabinet is constructed of 18-gauge steel
with a 14-gauge aluminum front cover. The unit has a
polyester powder paint finish in white or almond. End
caps are provided on all units.
Inlet/Outlet Grilles – The fresh air inlet grille is located
on the front of the unit. The outlet grille has openings
less than 0.25 inches to discourage tampering with the
heating element (pencil-proof).
72
Built-in Controls – Linear limit, automatic reset thermal cutout.
Electrical Connection – Each baseboard heater has
a junction box located on both ends and a built-in full
length wireway.
Installation Requirements – Field or factory-installed
low voltage relay and thermostat kits fit into the righthand junction box only.
904/906 Series
Factory Built-in Options
Code
Field-Installed Options
(shipped loose for field installation into heater)
Description
A
Bottom Air Inlet
D3
Disconnect Switch, 277V, Double-pole, 20 Amp
Catalog
Number
Description
Custom Length
906-124585(1) Inside Corner
M1
High Altitude Automatic Cutout
906-124586(1) Outside Corner
R1
24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp
906-124587
Round Pedestal Kit, 3-5”, Qty=2
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19
Amp
906-169806
Square Pedestal Kit, 2”, Qty=2
R6
Pneumatic Relay, 480V, 20 Amp
R7
Triac Proportional Relay, 277V Max., 2500W Max.
S
L
906-124588(1) Splice Plate 2” Long
906-124589(1)
Contour Splice Plate for Code A (Bottom Air Inlet)
and/or Heater with Pedestals
Smooth painted finish on heater back
906-124590
24V Relay Kit, 240V, 22 Amp; 277V, 25 Amp
T1
TamperproofThermostat,Single-pole,240V,25Amp;
277V, 10 Amp
906-124591
24V Relay Kit with Transformer, 120V, 22 Amp
906-124592
24V Relay Kit with Transformer, 208V, 22 Amp
T2
TamperproofThermostat,Double-pole,240V,25Amp;
277V, 10 Amp
906-124593
24V Relay Kit with Transformer, 240V, 22 Amp
24V Relay Kit with Transformer, 277V, 19 Amp
T5
Adjustable Thermostat, Single-pole, 240V, 25 Amp;
277V, 10 Amp
906-124594
906B-XXX(1)
Blank Section (specify length in inches-XXX)
(1) Change 906 prefix to 904 for sloped top.
AdjustableThermostat, Double-pole, 240V, 25 Amp;
277V, 10 Amp
Standard colors - Add W for white finish or A for almond finish to the
end of part number.
T6
C O N V E C T O R S
Architectural Sill-Height Convector
Architectural Sloped Top Sill-Height Convector
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
Remote Room Thermostat – See page 99
2-1/2"
4"
K.O. 1/4"
6-1/8"
3-7/8"
1-3/8"
1-7/8"
1-1/8"
2-3/8"
Rear View
15/16"
Side View
K.O. 7/8"
1-1/8"
7/8"
906 Series
Bottom View
2-3/8"
2-1/2"
4"
K.O. 1/4"
7-1/2"
3-7/8"
1-3/8"
1-7/8"
15/16"
2-3/8"
1-1/8"
Rear View
Side View
K.O. 7/8"
904 Series
1-1/8"
7/8"
2-3/8"
Bottom View
73
904/906 Series
C O N V E C T O R S
Architectural Sill-Height Convector
Architectural Sloped Top Sill-Height Convector
HX-906U (Flat Top)
HX-904U (Sloped Top)
How to order: Model + Heater Code with color code + Options
(example HX-906U01000BW-2632-T5)
Density
Length
Watts
In. (mm) W/Ft W/m
29
(738)
39
(992)
49.3
(1253)
58.8
(1494)
67.5
(1715)
76.9
(1952)
85.6
(2175)
94.5
(2400)
103.6
(2632)
Heater Code
120V
(1 Ph)
Amps
208V
(1 Ph)
Amps
277V
(1 Ph)
Watts at
Amps 240/208V
Amps
Weight Lbs (kg)
BCI
BCSI
(Flat) (Sloped)
100
330
200
00200B‡-738
1.7
00200C‡-738
1.0
—
—
200/150 00200V‡-738 0.8/0.7
150
490
300
00300B‡-738
2.5
00300C‡-738
1.4
00300N‡-738
1.1
300/225 00300V‡-738 1.3/1.1
200
650
400
00400B‡-738
3.3
00400C‡-738
1.9
00400N‡-738
1.4
8.0
400/300 00400V‡-738 1.7/1.4 (3.6)
275
900
500
00500B‡
4.2
00500C‡
2.4
00500N‡
1.8
500/375
100
330
300
00300B‡-992
2.5
00300C‡-992
1.4
00300N‡-992
1.1
300/225 00300V‡-992 1.3/1.1
150
490
450
00450B‡-992
3.8
00450C‡-992
2.2
00450N‡-992
1.6
200
650
600
00600B‡-992
5.0
00600C‡-992
2.9
00600N‡-992
2.2
450/338 00450V‡-992 1.9/1.6 10.4
600/450 00600V‡-992 2.5/2.2 (4.7)
275
100
900
330
750
00750B‡
400 00400B‡-1253
6.3
3.3
00750C‡
00400C‡-1253
3.6
00750N‡
2.7
1.9 00400N‡-1253 1.4
750/563
00750V‡
3.1/2.7
400/300 00400V‡-1253 1.7/1.4
150
490
600 00600B‡-1253
5.0
00600C‡-1253
2.9 00600N‡-1253 2.2
200
650
800 00800B‡-1253
6.7
00800C‡-1253
3.8 00800N‡-1253 2.9
600/450 00600V‡-1253 2.5/2.2 12.8
800/600 00800V‡-1253 3.3/2.9 (5.8)
275
900 1000
4.8
1000/750
100
330
500 00500B‡-1494
150
490
750 00750B‡-1494
200
650 1000 01000B‡-1494
275
900 1250
10.4
01250C‡
100
330
600 00600B‡-1715
5.0
00600C‡-1715
2.9 00600N‡-1715 2.2
600/450 00600V‡-1715 2.5/2.2
150
490
900 00900B‡-1715
7.5
00900C‡-1715
4.3 00900N‡-1715 3.2
200
650 1200 01200B‡-1715
10.0 01200C‡-1715
5.8 01200N‡-1715 4.3
900/675 00900V‡-1715 3.8/3.2 17.2
1200/900 01200V‡-1715 5.0/4.3 (7.8)
275
900 1500
12.5
01500C‡
7.2
100
330
5.8
00700C‡-1952
3.4 00700N‡-1952 2.5
150
490 1050 01050B‡-1952
8.8
01050C‡-1952
5.0 01050N‡-1952 3.8
200
650 1400 01400B‡-1952
11.7 01400C‡-1952
275
100
150
900 1750
—
330 800 00800B‡-2175
490 1200 01200B‡-2175
—
01750C‡
6.7 00800C‡-2175
10.0 01200C‡-2175
200
650 1600
—
—
01000B‡
01250B‡
01500B‡
700 00700B‡-1952
275
900 2000
100
330
150
490 1350
200
650 1800
275
900 2250
100
150
01000C‡
00500C‡-1494
2.4 00500N‡-1494 1.8
500/375 00500V‡-1494 2.1/1.8
6.3
00750C‡-1494
3.6 00750N‡-1494 2.7
8.3
01000C‡-1494
4.8 01000N‡-1494 3.6
750/563 00750V‡-1494 3.1/2.7 15.1
1000/750 01000V‡-1494 4.2/3.6 (6.8)
6.0
1250/938
01600C‡-2175
01250N‡
01500N‡
3.6
4.5
5.4 1500/1125
01000V‡
01250V‡
01500V‡
9.1
(4.1)
2.1/1.8
4.2
—
01000N‡
00500V‡
8.3
11.9
(5.4)
14.7
(6.6)
4.2/3.6
17.3
(7.9)
5.2/4.5
19.7
(9.0)
6.3/5.4
700/525 00700V‡-1952 2.9/2.5
1050/788 01050V‡-1952 4.3/3.8 19.4
6.7 01400N‡-1952 5.1 1400/1050 01400V‡-1952 5.8/5.0 (8.8)
22.3
(10.1)
8.4
01750N‡
6.3 1750/1313 01750V‡
7.3/6.3
3.8 00800N‡-2175 2.9
800/600 00800V‡-2175 3.3/2.9
5.8 01200N‡-2175 4.3 1200/900 01200V‡-2175 5.0/4.3 21.5
7.7 01600N‡-2175 5.8 1600/1200 01600V‡-2175 6.7/5.8 (9.7)
24.7
(11.2)
—
02000C‡
7.5
00900C‡-2400
4.3 00900N‡-2400 3.2
—
—
01350C‡-2400
—
—
01800C‡-2400
6.5 01350N‡-2400 4.9 1350/1013 01350V‡-2400 5.6/4.9 23.6 27.2
8.7 01800N‡-2400 6.5 1800/1350 01800V‡-2400 7.5/6.5 (10.7) (12.3)
—
—
02250C‡
330 1000 01000B‡-2632
8.3
01000C‡-2632
4.8 01000N‡-2632 3.6
490 1500
—
—
01500C‡-2632
7.2 01500N‡-2632 5.4 1500/1125 01500V‡-2632 6.3/5.4
200
650 2000
—
—
02000C‡-2632
200
650 2250
—
—
275
900 2500
—
—
900 00900B‡-2400
9.6
10.8
02000N‡
02250N‡
7.2 2000/1500
02000V‡
8.3/7.2
900/675 00900V‡-2400 3.8/3.2
8.1 2250/1688
02250V‡
9.4/8.1
1000/750 01000V‡-2632 4.2/3.6
9.6 02000N‡-2632 7.2 2000/1500 02000V‡-2632 8.3/7.2 25.8 29.7
(11.7) (13.5)
02250C‡-2632 10.8 02250N‡-2632 8.1 2250/1688 02250V‡-2632 9.4/8.1
02500C‡
12.0
02500N‡
9.0 2500/1875
Other voltages available. Consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number.
74
Heater Code
240/208V
(1 Ph)
02500V‡
10.4/9.0
905/907 Series
907
905
Applications
• Air, Rail or Bus Terminals
•Hallways
•Auditoriums
•Lobbies
•Corridors
•Offices
•Entryways
•Foyers
C O N V E C T O R S
Industrial Sill-Height Convector
Industrial Sloped Top Sill-Height Convector
The 905/907 Series industrial sill-height convector (also
known as draft barriers) are designed to fit under large windows to prevent cold down drafts. The heaters are ideal for
heavy traffic areas with high heating requirements.
• Installation Options: Units may be mounted to the wall
flush on the floor or on pedestals. Custom lengths and
blank sections and inside or outside corners are available
for wall-to-wall installations. Units can be ordered with
smooth painted finish when the back of the heater is visible.
• Length Options: Heaters can be installed singularly in
lengths from 20 inches to 103 inches or joined end to end
for complete perimeter heating.
• A
dded Safety: The sloped-top cabinet on the 905 Series
prevents objects from being set on top of the heater, which
can restrict airflow and cause overheating.
• Choice of Colors: Heaters can be matched to any décor.
White or almond is standard and a wide range of optional
colors and custom finishes are also available.
Standard Construction Features
Heating Elements – Stainless steel elements with
aluminum fins float on high temperature nylon bushings
for quiet operation.
Housing – Cabinet is constructed of 18-gauge steel
with a 16-gauge steel front cover. The unit has a polyester powder paint finish in white or almond. End caps
are provided on all units.
Inlet/Outlet Grilles – The fresh air inlet grille is located
on the front of the unit. The outlet grille has openings
less than 0.25 inches to discourage tampering with the
heating element (pencil-proof).
Built-in Controls – Linear limit, automatic reset thermal cutout.
Electrical Connection – Each baseboard heater has
a junction box located on both ends and a built-in full
length wireway.
Installation Requirements – Field or factory-installed
low voltage relay and thermostat kits fit into the righthand junction box only.
75
905/907 Series
C O N V E C T O R S
Industrial Sill-Height Convector
Industrial Sloped Top Sill-Height Convector
Factory Built-in Options
Code
Field-Installed Options
(shipped loose for field installation into heater)
Description
A
Bottom Air Inlet
D3
Disconnect Switch, 277V, Double-pole, 20 Amp
Catalog
Number
Description
Custom Length
907-124597(1) Inside Corner
M1
High Altitude Automatic Cutout
907-124598(1) Outside Corner
R1
24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp
907-124599
Round Pedestal Kit, 3-5”, Qty=2
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19
Amp
907-169807
Square Pedestal Kit, 2”, Qty=2
R6
Pneumatic Relay, 480V, 20 Amp
R7
Triac Proportional Relay, 277V Max., 2500W Max.
S
Smooth painted finish on heater back
907-124602
24V Relay Kit, 240V, 22 Amp; 277V, 25 Amp
T1
TamperproofThermostat,Single-pole,240V,25Amp;
277V, 10 Amp
907-124603
24V Relay Kit with Transformer, 120V, 22 Amp
907-124604
24V Relay Kit with Transformer, 208V, 22 Amp
T2
TamperproofThermostat,Double-pole,240V,25Amp;
277V, 10 Amp
907-124605
24V Relay Kit with Transformer, 240V, 22 Amp
24V Relay Kit with Transformer, 277V, 19 Amp
T5
Adjustable Thermostat, Single-pole, 240V, 25 Amp;
277V, 10 Amp
907-124606
907B-XXX(1)
Blank Section (specify length in inches-XXX)
(1) Change 907 prefix to 905 for sloped top.
AdjustableThermostat, Double-pole, 240V, 25 Amp;
277V, 10 Amp
Standard colors - Add W for white finish or A for almond finish to
the end of part number.
L
T6
907-124600(1) Splice Plate 2” Long
907-124601(1)
Contour Splice Plate for Code A (Bottom Air Inlet)
and/or Heater with Pedestals
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
Remote Room Thermostat – See page 99
2-1/2"
4"
K.O. 1/4"
6-1/8"
3-7/8"
1-3/8"
1-7/8"
1-1/8"
2-3/8"
15/16"
Side View
K.O. 7/8"
Rear View
1-1/8"
7/8"
907 Series
Bottom View
2-3/8"
2-1/2"
4"
K.O. 1/4"
7-1/2"
3-7/8"
1-3/8"
1-7/8"
15/16"
2-1/2"
1-1/8"
Rear View
Side View
K.O. 7/8"
76
905 Series
1-1/8"
7/8"
2-3/8"
Bottom View
905/907 Series
HX-907U (Flat Top)
HX-905U (Sloped Top)
How to order: Model + Heater Code with color code + Options
(example HX-905U01200NW-1708-T5)
Density
Length
Watts
In. (mm) W/Ft W/m
Heater Code
120V
(1 Ph)
Amps
208V
(1 Ph)
Amps
277V
(1 Ph)
Watts at
Amps 240/208V
Heater Code
240/208V
(1 Ph)
Amps
100
330
200
00200B‡-731
1.7
00200C‡-731
1.0
—
—
200/150 00200V‡-731 0.8/0.7
150
490
300
00300B‡-731
2.5
00300C‡-731
1.4
00300N‡-731
1.1
300/225 00300V‡-731 1.3/1.1
200
650
400
00400B‡-731
3.3
00400C‡-731
1.9
00400N‡-731
1.4
400/300 00400V‡-731 1.7/1.4
275
900
500
00500B‡
4.2
00500C‡
2.4
00500N‡
1.8
500/375
100
330
300
00300B‡-986
2.5
00300C‡-986
1.4
00300N‡-986
1.1
300/225 00300V‡-986 1.3/1.1
150
490
450
00450B‡-986
3.8
00450C‡-986
2.2
00450N‡-986
1.6
450/338 00450V‡-986 1.9/1.6
200
650
600
00600B‡-986
5.0
00600C‡-986
2.9
00600N‡-986
2.2
600/450 00600V‡-986 2.5/2.2
275
900
750
00750B‡
6.3
00750C‡
3.6
00750N‡
2.7
750/563
100
330
400 00400B‡-1246 3.3 00400C‡-1246 1.9 00400N‡-1246 1.4
400/300 00400V‡-1246 1.7/1.4
150
49
(1246) 200
490
600 00600B‡-1246 5.0 00600C‡-1246 2.9 00600N‡-1246 2.2
600/450 00600V‡-1246 2.5/2.2
650
800 00800B‡-1246 6.7 00800C‡-1246 3.8 00800N‡-1246 2.9
800/600 00800V‡-1246 3.3/2.9
28.8
(731)
38.8
(986)
275
900 1000
100
330
500 00500B‡-1486 4.2 00500C‡-1486 2.4 00500N‡-1486 1.8
01000B‡
8.3
01000C‡
4.8
01000N‡
3.6
58.6 150
(1486) 200
490
1000/750
00500V‡
00750V‡
01000V‡
275
900 1250
1250/938
100
330
600 00600B‡-1708 5.0 00600C‡-1708 2.9 00600N‡-1708 2.2
67.3 150
(1708) 200
490
900 00900B‡-1708 7.5 00900C‡-1708 4.3 00900N‡-1708 3.2
900/675 00900V‡-1708 3.8/3.2
650 1200 01200B‡-1708 10.0 01200C‡-1708 5.8 01200N‡-1708 4.3
1200/900 01200V‡-1708 5.0/4.3
275
900 1500
100
330
76.6 150
(1945) 200
12.5
01500C‡
7.2
01500N‡
4.5
01250V‡
5.4 1500/1125
01500V‡
1050/788 01050V‡-1945 4.3/3.8
650 1400 01400B‡-1945 11.7 01400C‡-1945 6.7 01400N‡-1945 5.1 1400/1050 01400V‡-1945 5.8/5.0
330
—
—
01750C‡
8.4
01750N‡
6.3 1750/1313
800 00800B‡-2168 6.7 00800C‡-2168 3.8 00800N‡-2168 2.9
18.7
(8.5)
17.0
(7.7)
22.0
(10.0)
18.8
(8.5)
25.0
(11.4)
20.8
(9.4)
28.3
(12.8)
31.3
(14.2)
6.3/5.4
490 1050 01050B‡-1945 8.8 01050C‡-1945 5.0 01050N‡-1945 3.8
900 1750
14.9
(6.8)
5.2/4.5
700/525 00700V‡-1945 2.9/2.5
100
15.1
(6.9)
600/450 00600V‡-1708 2.5/2.2
700 00700B‡-1945 5.8 00700C‡-1945 3.4 00700N‡-1945 2.5
275
85.4 150
(2168) 200
01500B‡
01250N‡
12.7
(5.8)
4.2/3.6
750/563 00750V‡-1486 3.1/2.7
6.0
11.6
(5.3)
500/375 00500V‡-1486 2.1/1.8
1000/750 01000V‡-1486 4.2/3.6
01250C‡
10.4
(4.8)
3.1/2.7
750 00750B‡-1486 6.3 00750C‡-1486 3.6 00750N‡-1486 2.7
10.4
BII
BISI
(Flat) (Sloped)
2.1/1.8
650 1000 01000B‡-1486 8.3 01000C‡-1486 4.8 01000N‡-1486 3.6
01250B‡
Weight Lbs (kg)
01750V‡
7.3/6.3
800/600 00800V‡-2168 3.3/2.9
650 1600
490 1200 01200B‡-2168 10.0 01200C‡-2168 5.8 01200N‡-2168 4.3
—
1200/900 01200V‡-2168 5.0/4.3 22.7
— 01600C‡-2168 7.7 01600N‡-2168 5.8 1600/1200 01600V‡-2168 6.7/5.8 (10.3)
275
900 2000
—
—
100
330
02000C‡
9.6
02000N‡
7.2 2000/1500
900 00900B‡-2393 7.5 00900C‡-2393 4.3 00900N‡-2393 3.2
02000V‡
8.3/7.2
900/675 00900V‡-2393 3.8/3.2
94.2 150
(2393) 200
490 1350
—
650 1800
—
— 01350C‡-2393 6.5 01350N‡-2393 4.9 1350/1013 01350V‡-2393 5.6/4.9
24.6
— 01800C‡-2393 8.7 01800N‡-2393 6.5 1800/1350 01800V‡-2393 7.5/6.5 (11.2)
275
900 2250
—
—
100
330 1000 01000B‡-2625 8.3 01000C‡-2625 4.8 01000N‡-2625 3.6
02250C‡
10.8
02250N‡
8.1 2250/1688
02250V‡
9.4/8.1
490 1500
—
— 01500C‡-2625 7.2 01500N‡-2625 5.4 1500/1125 01500V‡-2625 6.3/5.4
650 2000
—
— 02000C‡-2625 9.6 02000N‡-2625 7.2 2000/150002000V‡-26252 8.3/7.2
650 2250
—
— 02250C‡-2625 10.8 02250N‡-2625 8.1 2250/1688 02250V‡-2625 9.4/8.1
275
900 2500
—
—
12.0
02500N‡
34.4
(15.6)
1000/750 01000V‡-2625 4.2/3.6
150
103.4 200
(2625)
200
02500C‡
C O N V E C T O R S
Industrial Sill-Height Convector
Industrial Sloped Top Sill-Height Convector
9.0 2500/1875
02500V‡
26.6
(12.1)
37.6
(17.1)
10.4/9.0
Other single-phase voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.
77
908/909 Series
C O N V E C T O R S
Architectural Convector
Architectural Sloped Top Convector
909
908
Applications
•Banks
•Halls
•Classrooms
•Offices
The 908/909 Series architectural convectors are
designed to heat large commercial spaces without the
fan noise associated with unit heaters.
• Installation Options: Units may be mounted to
the wall, flush on the floor or on pedestals. Custom
lengths, blank sections, sub-bases and inside or
outside corners are available for wall-to-wall installations. Units and accessories can be ordered with
smooth painted finish when the back of the heater is
visible.
• Added Safety: The sloped-top cabinet on the 908
Series prevents objects from being set on top of the
heater, which can restrict airflow and cause overheating.
• Recessed Mounting: The 909 Series heater can be
fully recessed when the front warm air outlet option
is used.
• C
hoice of Colors: Heaters can be matched to any
décor. White or almond is standard and a wide range
of optional colors and custom finishes are also available.
• Conference Rooms
Standard Construction Features
Heating Elements – Stainless steel elements with
aluminum fins float on high temperature nylon bushings
for quiet operation.
Housing – Cabinet is constructed of 20-gauge steel
with a 16-gauge steel front cover. The unit has a polyester powder paint finish in white or almond.
Inlet/Outlet Grilles – The fresh air inlet grille is located
on the front of the unit. An extruded aluminum outlet
grille discourages tampering with the heating element.
78
Built-in Controls – Linear limit, automatic reset thermal cutout.
Installation Requirements – Field or factory-installed
low voltage relay and thermostat kits.
Rough In Dimensions – 909 only: Heater Length + 1”
wide x 15” high x 6” deep.
908/909 Series
Factory Built-in Options
Code
D1
Description
Disconnect Switch, Three-pole, 600V, 40 Amp
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
F
Front Air outlet (Flat Top Only)
R1
24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19
Amp
R3
24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp
R4
240V Relay, Single-pole, 240V, 25 Amp
R5
240V Relay, Double-pole, 240V, 25 Amp
R6
Pneumatic Relay, 480V, 20 Amp
R7
Triac Proportional Relay, 277V Max., 2500W Max.
S
Smooth painted finish on heater back
909-124615
T1
TamperproofThermostat,Single-pole,240V,30Amp;
480V, 15 Amp
909-124616
75.2 (1909)
909-124617
83.2 (2112)
T2
TamperproofThermostat,Double-pole,480V,15Amp
909-218276(1)
27.2 (690)
X1
240V Transformer - 50 VA
909-218277(1)
37.2 (944)
X2
24V Transformer - 50 VA
909-218278(1)
909-124609
Flat Top Corner (interior and exterior)
908-124609
Sloped Top inside corner
908-218356
Sloped Top outside corner
909-124610
Square Pedestal Kit
27.2 (690)
909-124612
37.2 (944)
909-124614
909-218279(1)
909-218280(1)
Remote Room Thermostat – See page 99
Sub Base
Heater Length
In. (mm)
Empty Cabinet
Length
In. (mm)
47.2 (1198)
57.2 (1452)
65.2 (1655)
83.2 (2112)
909-124608
27.2 (690)
909-124619
37.2 (944)
Recessed Trim Kit
Heater Length
In. (mm)
47.2 (1198)
57.2 (1452)
65.2 (1655)
909-124623
75.2 (1909)
909-124624
83.2 (2112)
909-124625(1)
909-124626(1)
909-124627(1)
Filler Section
Length
In. (mm)
909-124628(1) Control Box - 12”
Filler sections can be cut to length in the field.
65.2 (1655)
909-218282(1)
909-124622
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
57.2 (1452)
75.2 (1909)
909-124621
Standard colors - Add W for white finish or A for almond finish to the
end of part number.
47.2 (1198)
909-218281(1)
909-124620
(1) Change 909 prefix to 908 for sloped top.
3-4” High
909-124611
909-124613
C O N V E C T O R S
Architectural Convector
Architectural Sloped Top Convector
12 (305)
24 (610)
36 (914)
12 (306)
909-124629
24V Relay Kit, Single-pole, 240V, 22 Amp; 277V,
19 Amp
909-124630
24V Relay Kit, Double-pole, 240V, 25 Amp
909-124631
240V Relay Kit, Single-pole, 240V, 22 Amp
909-124632
240V Relay Kit, Double-pole, 240V, 25 Amp
909-124633
24V Relay Kit with Transformer, 208V, 22 Amp
909-124634
24V Relay Kit with Transformer, 240V, 22 Amp
909-124635
24V Relay Kit with Transformer, 277V, 19 Amp
909-124636
Transformer Kit-208/24V - 50 VA
909-124637
Transformer Kit-240/24V - 50 VA
909-124638
Transformer Kit-277/24V - 50 VA
79
908/909 Series
C O N V E C T O R S
Architectural Convector
Architectural Sloped Top Convector
Unit With Grille On Top
Not recessed
Unit With Grille On Front (Option F)
7-1/2"
Front View
14"
2"
8-1/2"
4-1/2"
3"
K.O. Ø1-1/8 - Ø7/8"
K.O. Ø1/4"
K.O. Ø7/8"
Right Side
View
K.O.Ø1/4"
8-1/32" 4"
K.O.Ø1-1/8"Ø7/8"
2"
2-1/4"
5-3/1
2"
Bottom View
909 Series
2-1/32"
2-1/32"
K.O. 1-1/8"
4"
7-17/32"
4"
K.O. 7/8"
2"
K.O. 1/4"
4-1/32"
14-1/16"
2-27/32"
4-15/32"
2"
L
Rear View
K.O. 1/4"
Front View
2-21/32"
908 Series
2-1/32"
K.O. 1-1/8"
2"
5-3/16"
2-9/32"
2-21/32"
Bottom View
80
2-31/32"
4-15/32"
2-1/32"
Left Side View
908/909 Series
HX-909U (Flat Top)
HX-908U (Sloped Top)
How to order: Model + Heater Code with color code + Options
(example HX-909U02000NW-1655-T1)
Density
Length
In.
(mm)
W/Ft
27.2
(690)
375
1250
500
1640
375
1250
500
37.2
(944)
Heater Code
Watts
Heater Code
208V
(1 Ph)
Amps
277V
(1 Ph)
Amps
800
00800C‡-690
3.8
00800N‡-690
2.9
1000
01000C‡
4.8
01000N‡
3.6
1000
01000C‡-944
4.8
01000N‡-944
3.6
1640
1500
01500C‡
7.2
01500N‡
W/m
Watts at
240/208V
240/208V
(1 Ph)
Amps
800/600
00800V‡-690
3.3/2.9
1000/750
01000V‡
4.2/3.6
1000/750
01000V‡-944
4.2/3.6
5.4
1500/1125
01500V‡
6.3/5.4
47.2
(1198)
375
1250
1500
01500C‡-1198
7.2
01500N‡-1198
5.4
1500/1125
01500V‡-1198
6.3/5.4
500
1640
2000
02000C‡
9.6
02000N‡
7.2
2000/1500
02000V‡
8.3/7.2
57.2
(1452)
375
1250
1750
01750C‡-1452
8.4
01750N‡-1452
6.3
1750/1313
01750V‡-1452
7.3/6.3
500
1640
2500
02500C‡
12.0
02500N‡
9.0
2500/1875
02500V‡
10.4/9.0
375
1250
2000
02000C‡-1655
9.6
02000N‡-1655
7.2
2000/1500
02000V‡-1655
8.3/7.2
500
1640
3000
03000C‡
14.4
03000N‡
10.8
3000/2250
03000V‡
12.5/10.8
75.2
(1909)
375
1250
2500
02500C‡-1909
12.0
02500N‡-1909
9.0
2500/1875
02500V‡-1909
10.4/9.0
500
1640
3500
03500C‡(1)
16.8
03500N‡
12.6
3500/2625
03500V‡
14.6/12.6
83.2
(2112)
375
1250
2750
02750C‡-2112
13.2
02750N‡-2112
9.9
2750/2066
02750V‡-2112
11.5/9.9
500
1640
4000
04000C‡(1)
19.2
04000N‡
14.4
4000/3000
04000V‡
16.7/14.4
65.2
(1655)
Weight Lbs (kg)
BAI
(Flat)
BASI
(Sloped)
30
(13.6)
32.0
(14.5)
46
(20.9)
46
(20.9)
57
(25.9)
57
(25.9)
66
(29.9)
66
(30)
75
(34.0)
75
(34.1)
80
(36.3)
80
(36.3)
89
(40.4)
89
(40.5)
C O N V E C T O R S
Architectural Convector
Architectural Sloped Top Covector
Other single-phase voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.
(1) If control option R7 is required for these heaters, (Qty 2) R7 Triac proportional relays are required.
81
914 Series
D R A F T
B A R R I E R S
Mini Draft Barrier Heater
Applications
• Commercial Buildings
•Entryways
•Hallways
•Schools
The 914 Series mini draft barrier heaters are designed
to fit under large windows to prevent cold down drafts.
The heater provides total or supplemental heating for a
variety of applications.
• Installation Options: Units may be wall mounted
or installed on the floor using pedestal kits. Custom
lengths, blank sections, and inside or outside corners are available for wall-to-wall installations. Units
can be ordered with smooth painted finish mounting
plates when the back of the heater is visible.
• Choice of Colors: Heaters can be matched to any
décor. White or almond is standard and a wide
range of optional colors and custom finishes including anodized aluminum are available.
Standard Construction Features
Heating Elements – Stainless steel elements with alumi-
num fins float on high temperature nylon bushings for
quiet operation.
Housing – Cabinet is constructed of 18-gauge steel
with a 14-gauge aluminum front and top covers. The
unit has a polyester powder paint finish in white or
almond. End caps are provided on all units.
Inlet/Outlet Grilles – The fresh air inlet is located on
the bottom of the unit. The top outlet grille has openings less than 0.25 inches to discourage tampering with
the heating element (pencil-proof).
82
Built-in Controls – Linear limit, automatic reset thermal
cutout.
Electrical Connection – Each heater has a junction box
located at the right end and a built-in full length wireway. Separate low voltage wireway is available.
Mounting Requirements – Minimum installation height
above the floor is two inches. Field or factory-installed
low voltage relay and thermostat kits fit into the righthand junction box only.
914 Series
Factory Built-in Options
(shipped loose for field installation into heater)
Description
D3
Disconnect Switch, Double-pole, 277V, 20 Amp
F1
24V Wireway
L
Custom Length
M1
High Altitude Automatic Cutout
R1
24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19
Amp
R6
Pneumatic Relay, 480V, 20 Amp
R7
Triac Proportional Relay 277V Max., 2500W Max.
S
Smooth painted finish on heater back
T1
TamperproofThermostat,Single-pole, 240V,25 Amp;
600V, 10 Amp
T2
TamperproofThermostat,Double-pole,240V,25Amp;
600V, 10 Amp
T5
Adjustable Thermostat, Single-pole, 240V, 25 Amp;
600V, 10 Amp
T6
Adjustable Thermostat, Double-pole, 240V, 25Amp;
600V, 10 Amp
Catalog
Number
Description
914-166740
Inside Corner
914-166741
Outside Corner
914-166742
Round Pedestal Kit, 3-5”, Qty 2
914-166743
Square Pedestal Kit, 2”, Qty 2
914-166744
Splice Plate 2” Long
914-166745
ContouredSplicePlateforCodeS(smoothpainted
finishonheaterback)and/orHeaterwithPededstals
914-166746
24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp
914-166747
24V Relay Kit with Transformer, 208V, 22 Amp
914-166748
24V Relay Kit with Transformer, 240V, 22 Amp
914-166749
24V Relay Kit with Transformer, 277V 19 Amp
914B-XXX
Blank Section (specify length in inches-XXX)
B A R R I E R S
Code
Field-Installed Options
D R A F T
Mini Draft Barrier Heater
Standard colors - Add W for white finish or A for almond finish to the
end of part number.
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
Remote Room Thermostat – See page 99
2-1/2"
Top View
Top View
2-1/2"
4-1/2"
Top View
2"
3-3/16"
2"
Rear View
RearView
K.O.O7/8"
K.O.O7/8"
3-3/4"
Smooth Finish on
ter
hea
back - (S) Standard inish
F
on er
heat
back
RearView
3-3/16"
3-3/4"
Smooth Finish on
ter
hea
back - (S) Standard inish
F
on er
heat
back
FrontView
Front View
FrontView
1"
4-1/2"
1-5/8"
1"
Side
Vie
w
Side
View
1-5/8"
SideView
Sufficie
ntHeight
2" rom
f Floor
Sufficie
ntHeight
2" rom
f Floor
Shown with optional square pedestal.
83
914 Series
B A R R I E R S
Mini Draft Barrier Heater
HX-914U
How to order: Model + Heater Code with color code + Options
(example HX-914U00400NW-1200-T5)
D R A F T
Density
Length
Watts
In. (mm) W/Ft W/m
27.6
(700)
35.4
(900)
47.3
(1200)
59.1
(1500)
70.9
(1800)
82.7
(2100)
94.5
(2400)
Heater Code
208V
(1 Ph)
Amps
277V
(1 Ph)
Amps
480V
(1 Ph)
Heater Code
Watts
Amps 240/208V
240/208V
(1 Ph)
150 490 300
00300C‡-700
1.4
00300N‡-700
1.1
—
—
300/225
175 574 350
00350C‡
1.7
00350N‡
1.3
—
—
350/263
00300V‡-700 1.3/1.1
100 330 300
00300C‡-900
1.4
00300N‡-900
1.1
00300T‡-900
0.6
300/225
00300V‡-900 1.3/1.1
150 490 450
00450C‡-900
2.2
00450N‡-900
1.6
00450T‡-900
0.9
450/338
00450V‡-900 1.9/1.6
175 574 525
00525C‡
2.5
00525N‡
1.9
00350V‡
00525T‡
1.1
525/394
1.9
00400N‡-1200 1.4
00400T‡-1200
0.8
400/300
00400V‡-1200 1.7/1.4
150 490 600 00600C‡-1200
2.9
00600N‡-1200 2.2
00600T‡-1200
1.3
600/450
00600V‡-1200 2.5/2.2
175 574 700
3.4
00700T‡
1.5
700/526
00700C‡
00700N‡
2.5
00525V‡
1.5/1.3
100 330 400 00400C‡-1200
00700V‡
2.4
00500N‡-1500 1.8
00500T‡-1500
1.0
500/375
00500V‡-1500 2.1/1.8
3.6
00750N‡-1500 2.7
00750T‡-1500
1.6
750/563
00750V‡-1500 3.1/2.7
175 574 875
4.2
00875T‡
1.8
875/657
00875N‡
3.2
00875V‡
2.9
00600N‡-1800 2.2
00600T‡-1800
1.3
600/450
00600V‡-1800 2.5/2.2
150 490 900 00900C‡-1800
4.3
00900N‡-1800 3.2
00900T‡-1800
1.9
900/675
00900V‡-1800 3.8/3.2
175 574 1050
5.0
01050T‡
2.2
1050/789
01050N‡
3.8
01050V‡
3.4
00700N‡-2100 2.5
00700T‡-2100
1.5
700/525
150 490 1050 01050C‡-2100
5.0
01050N‡-2100 3.8
01050T‡-2100
2.2
1050/788 01050V‡-2100 4.4/3.8
175 574 1225
5.9
01225T‡
2.6
1225/920
3.8
00800N‡-2400 2.9
00800T‡-2400
1.7
800/600
150 490 1200 01200C‡-2400
5.8
01200N‡-2400 4.3
01200T‡-2400
2.5
1200/900 01200V‡-2400 5.0/4.3
175 574 1400
6.7
01400T‡
2.9
1400/1052
01400N‡
4.4
5.1
12
(5.5)
13.9
(6.3)
00700V‡-2100 2.9/2.5
100 330 800 00800C‡-2400
01400C‡
01225N‡
10.2
(4.6)
4.4/3.8
100 330 700 00700C‡-2100
01225C‡
8.3
(3.8)
3.6/3.2
100 330 600 00600C‡-1800
01050C‡
7
(3.2)
2.9/2.5
100 330 500 00500C‡-1500
00875C‡
Weight
Lbs (kg)
2.2/1.9
150 490 750 00750C‡-1500
01225V‡
15.8
(7.2)
5.1/4.4
00800V‡-2400 3.3/2.9
Other voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated
84
Amps
01400V‡
5.8/5.1
17.6
(8)
916 Series
D R A F T
High Watt Density Draft Barrier
B A R R I E R S
Applications
• Commercial Buildings
•Hospitals
•Entryways
• Shopping Centers
•Hallways
The 916 Series high watt density draft barrier heaters
are designed to fit under large windows to prevent cold
down drafts. The heater provides total or supplemental
heating for a variety of applications.
• Installation Options: Units may be wall mounted
or installed on the floor using pedestal kits. Custom
lengths, blank sections and inside or outside corners
are available for wall-to-wall installations. Units can
be ordered with smooth painted finish when the back
of the heater is visible.
• Choice of Colors: Heaters can be matched to any
décor. White or almond is standard and a wide range
of optional colors and custom finishes, including anodized aluminum, are also available.
Standard Construction Features
Heating Elements – Two stainless steel elements
Built-in Controls – Linear limit, automatic reset thermal
with aluminum fins float on high temperature nylon
bushings for quiet operation.
cutout.
Housing – Cabinet is constructed of 18-gauge steel with
located at the right end and a built-in full length wireway.
Seprate low voltage wireway is available.
a 14-gauge aluminum front and top covers. The unit
has a polyester powder paint finish in white or almond.
End caps are provided on all units.
Inlet/Outlet Grilles – The fresh air inlet is located on the
bottom of the unit. The top outlet grille has openings
less than 0.25 inches to discourage tampering with the
heating element (pencil-proof).
Electrical Connection – Each heater has a junction box
Installation Requirements – Minimum installation height
above the floor is three inches. Field or factory-installed
low voltage relay and thermostat kits fit into the right-hand
junction box only.
85
916 Series
B A R R I E R S
High Watt Density Draft Barrier Heater
Factory Built-in Options
D R A F T
Code
Field-Installed Options
(shipped loose for field installation into heater)
Description
D1
Disconnect Switch, Three-pole, 600V, 40 Amp
D3
Disconnect Switch, Double-pole, 277V, 20 Amp
F1
24V Wireway
L
Custom Length
Catalog
Number
M1
High Altitude Automatic Cutout
R1
24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp
R2
24V Relay with Transformer, 240V, 22 Amp; 277V,
19 Amp
R6
Pneumatic Relay, 480V, 20 Amp
R7
Triac Proportional Relay 277V Max., 2500W Max.
S
Smooth painted finish on heater back
T1
TamperproofThermostat,Single-pole, 240V, 25Amp;
600V, 10 Amp
T2
TamperproofThermostat,Double-pole,240V,25Amp;
600V, 10 Amp
Description
916-166753
Inside Corner
916-166754
Outside Corner
916-166756
Square Pedestal Kit, 3”, Qty 2
916-166757
Splice Plate 2” Long
916-166758
ContouredSplicePlateforCodeS(smoothpainted
finishonheaterback)and/orHeaterwithPededstals
916-166759
24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp
916-166760
24V Relay Kit with Transformer, 208V, 22 Amp
916-166761
24V Relay Kit with Transformer, 240V, 22 Amp
916-166762
24V Relay Kit with Transformer, 277V 19 Amp
916B-XXX
Blank Section (specify length in inches-XXX)
Standard colors - Add W for white finish or A for almond finish to
the end of part number.
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
Remote Room Thermostat – See page 99
5-3/4"
Top
TopView
View
O1/4"
6"
3"
1-7/8"
K.O. O7/8"
RearView
View
Rear
Front View
2-1/4"
3-3/16"
Smooth Finish on heater back - (S)
Standard Finish
on heater back
3-3/16"
Side
SideView
View
Shown with optional square pedestals.
Front View
Sufficient Height
3” from Floor
86
916 Series
Density
Length
In. (mm)
23.6
(600)
35.4
(900)
47.3
(1200)
59.1
(1500)
70.9
(1800)
82.7
(2100)
94.5
(2400)
Heater Code
Heater Code
Watts at
Amps 240/208V
Watts
208V
(1 Ph)
Amps
277V
(1 Ph)
Amps
480V
(1 Ph)
575
375
00375C‡-600
1.8
00375N‡-600
1.4
—
—
250
820
500
00500C‡-600
2.4
00500N‡-600
1.8
—
355
1165
750
00750C‡
3.6
00750N‡
2.7
500
1640
1000
01000C‡-600
4.8
01000N‡-600
175
575
500
00500C‡-900
2.4
00500N‡-900
250
820
750
00750C‡-900
3.6
355
1165
1000
01000C‡
500
1640
1500
01500C‡-900
175
575
700
250
240/208V
(1 Ph)
Amps
375/281
00375V‡-600
1.6/1.4
—
500/375
00500V‡-600
2.1/1.8
—
—
750/563
00500V‡
3.1/2.7
3.6
01000T‡-600
2.1
1000/750
01000V‡-600
4.2/3.6
1.8
00500T‡-900
1.0
500/375
00500V‡-900
2.1/1.8
00750N‡-900
2.7
00750T‡-900
1.6
750/563
00750V‡-900
3.1/2.7
4.8
01000N‡
3.6
01000T‡
2.1
1000/751
01000V‡
4.2/3.6
7.2
01500N‡-900
5.4
01500T‡-900
00700C‡-1200 3.4
00700N‡-1200
2.5
00700T‡-1200 1.5
700/525
820
1000 01000C‡-1200 4.8
01000N‡-1200
3.6
01000T‡-1200 2.1
1000/750 01000V‡-1200 4.2/3.6
355
1165
1400
01400N‡
5.1
500
1640
2000 02000C‡-1200 9.6
02000N‡-1200
7.2
02000T‡-1200 4.2 2000/1500 02000V‡-1200 8.3/7.2
175
575
875
00875C‡-1500 4.2
00875N‡-1500
3.2
00875T‡-1500 1.8
875/656
250
820
1250 01250C‡-1500 6.0
01250T‡-1500 2.6
1250/938 01250V‡-1500 5.2/4.5
355
1165
1750
500
1640
2500 02500C‡-1500
175
W/Ft
W/m
175
01400C‡
6.7
01400T‡
3.1 1500/1125 01500V‡-900
2.9 1400/1052
01400V‡
5.8/5.1
4.5
6.3
12
02500N‡-1500
9.0
02500T‡-1500 5.2 2500/1875 02500V‡-1500 10.4/9.0
575
1050 01050C‡-1800 5.0
01050N‡-1800
3.8
01050T‡-1800 2.2
250
820
1500 01500C‡-1800 7.2
01500N‡-1800
5.4
01500T‡-1800 3.1 1500/1125 01500V‡-1800 6.3/5.4
355
1165
2100
02100N‡
7.6
500
1640
3000 03000C‡-1800 14.4 03000N‡-1800 10.8 03000T‡-1800 6.3 3000/2250 03000V‡-1800 12.5/10.8
02100C‡
10.1
02100T‡
01750V‡
7.3/6.3
4.4 2100/1577
02100V‡
8.8/7.6
175
575
1225 01225C‡-2100 5.9
01225N‡-2100
4.4
01225T‡-2100 2.6
820
1750 01750C‡-2100 8.4
01750N‡-2100
6.3
01750T‡-2100 3.6 1750/1313 01750V‡-2100 7.3/6.3
355
1165
2450
02450N‡
8.8
500
1640
3500 03500C‡-2100 16.8 03500N‡-2100 12.6 03500T‡-2100 7.3 3500/2625 03500V‡-2100 14.6/12.6
11.8
02450T‡
5.1 2450/1840
02450V‡
10.2/8.8
175
575
1400 01400C‡-2400 6.7
01400N‡-2400
5.1
01400T‡-2400 2.9 1400/1050 01400V‡-2400 5.8/5.0
820
2000 02000C‡-2400 9.6
02000N‡-2400
7.2
02000T‡-2400 4.2 2000/1500 02000V‡-2400 8.3/7.2
355
1165
2800
02800N‡
10.1
500
1640
4000 04000C‡-2400 19.2 04000N‡-2400 14.4 04000T‡-2400 8.3 4000/3000 04000V‡-2400 16.7/14.4
13.5
02800T‡
24.6
(11.1)
1225/919 01225V‡-2100 5.1/4.4
250
02800C‡
21.1
(9.6)
1050/788 01050V‡-1800 4.4/3.8
250
02450C‡
17.6
(8.0)
00875V‡-1500 3.6/3.2
01750N‡
3.6 1750/1314
14.1
(6.4)
00700V‡-1200 2.9/2.5
01250N‡-1500
01750T‡
10.7
(4.8)
6.3/5.4
8.4
01750C‡
Weight
Lbs (kg)
B A R R I E R S
HZ-916U
How to Order: Model + Heater Code with color code + Options
(example HX-916U00875CW-1500-T1)
D R A F T
High Watt Density Draft Barrier
5.8 2800/2103
02800V‡
28.0
(12.7)
31.5
11.7/10.1 (14.3)
Other voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.
87
911/912 Series
C O N V E C T O R S
Architectural Cabinet Convector
Architectural Sloped Top Cabinet Convector
912
911
Applications
The 911/912 convectors are designed to heat large
commercial spaces. They provide large amounts of
heat without the fan noise associated with unit heaters.
• Installation Options: Units may be mounted to the
wall, flush on the floor or on pedestals. 912 Series
units can be fully recessed when the front warm air
outlet option is used.
• A
dded Safety: The sloped-top cabinet on the 911
Series prevents objects from being set on top of the
heater, which can restrict airflow and cause overheating.
• W
all-to-Wall Installation: A finished back mounting plate is available so that the unit can be mounted
against glass walls.
•Classrooms
• Conference Rooms
•Hallways
•Lobbies
Standard Construction Features
Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for
quiet operation.
Housing – Cabinet is constructed of 20-gauge steel with
a 16-gauge steel front cover. The unit has a polyester
powder paint finish in white or almond. Mounting holes
are provided along the back of the cabinet for wall installation.
88
Inlet/Outlet Grilles – The fresh air inlet grille is located
on the front of the unit. An extruded aluminum outlet
grille discourages tampering with the heating elements.
Built-in Controls – Linear limit, automatic reset thermal
cutout.
Rough In Dimensions – 912 Series only: Heater
Length + 1” wide x 21” high x 6” deep.
911/912 Series
Factory Built-in Options
Code
D1
Description
Disconnect Switch, Three-pole, 600V, 40 Amp
F
Front Air outlet (912 Series Only)
R1
24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp
R2
24V Relay with Transformer, 240V, 22 Amp; 277V, 19
Amp
R3
R4
Field-Installed Options
(shipped loose for field installation into heater)
Catalog
Number
Description
912-124546
Flat Top Corner (interior and exterior)
911-124546
Sloped Top inside corner
911-218358
Sloped Top outside corner
24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp
912-124547
UniversalRoundPedestalKit 3-4” High
240V Relay, Single-pole, 240V, 25 Amp
912-124548
27.2 (690)
R5
240V Relay, Double-pole, 240V, 25 Amp
912-124549
R6
Pneumatic Relay, 480V, 20 Amp
912-124550
R7
Triac Proportional Relay, 277V Max., 2500W Max.
912-124551
S
Smooth painted finish on heater back
912-124552
65.2 (1655)
T1
TamperproofThermostat,Single-pole,240V,30Amp;
480V, 15 Amp
912-218283(1)
27.2 (690)
912-218284(1)
Sub Base
Heater Length
In. (mm)
Empty Cabinet
Length
In. (mm)
37.2 (944)
47.2 (1198)
57.2 (1452)
37.2 (944)
T2
TamperproofThermostat,Double-pole,480V,15Amp
912-218285(1)
X1
240V Transformer - 50 VA
912-218286(1)
X2
24V Transformer - 50 VA
912-218287(1)
65.2 (1655)
912-124553
27.2 (690)
912-124554
912-124555
Remote Room Thermostat – See page 99
912-124556
Recessed Trim Kit
Heater Length
In. (mm)
912-124557
912-124558(1)
912-124559(1)
912-124560(1)
47.2 (1198)
57.2 (1452)
37.2 (944)
47.2 (1198)
57.2 (1452)
65.2 (1655)
Filler Section
Length
In. (mm)
912-124561(1) Control Box - 12”
12 (305)
24 (610)
36 (914)
12 (306)
912-124562
24V Relay Kit, Single-pole, 240V, 22 Amp; 277V,
19 Amp
912-124563
24V Relay Kit, Double-pole, 240V, 25 Amp; 277V,
19 Amp
912-124564
240V Relay Kit, Double-pole, 240V, 25 Amp
912-124565
240V Relay Kit, Single-pole, 240V, 22 Amp
912-124566
24V Relay Kit with Transformer, 208V, 22 Amp
912-124567
24V Relay Kit with Transformer, 240V, 22 Amp
(1) Change 912 prefix to 911 for sloped top.
912-124568
24V Relay Kit with Transformer, 277V, 19 Amp
Standard colors - Add W for white finish or A for almond finish to the
end of part number.
912-124569
Transformer Kit-208/24V - 50 VA
912-124570
Transformer Kit-240/24V - 50 VA
912-124571
Transformer Kit-277/24V - 50 VA
Special or custom colors - See inside back cover for color codes to be
added to end of part number.
Filler sections can be cut to length in the field.
C O N V E C T O R S
Architectural Cabinet Convector
Architectural Sloped Top Cabinet Convector
89
911/912 Series
C O N V E C T O R S
Architectural Cabinet Convector
Architectural Sloped Top Cabinet Convector
Unit With Grille On Top
K.O. 4" X 2"
7-1/4"
K.O.
¯ 1/4"
K.O.
¯ 7/8"
2-1/2"
8"
8-1/2"
K.O. ¯ 7/8"
12-1/2"
6"
Unit With Grille On Front (Option F)
5-3/16"
Rear View
20-3/16"
Left Side
View
K.O.
¯ 7/8"
2"
Bottom View
L
912 Series
K.O. ¯ 7/8"
K.O. ¯ 1/4"
2"
20-3/16"
8-15/32"
2"
8"
K.O.
¯ 1-1/8"
6"
L
4-1/32"
Rear View
5-3/16"
Front View
Left
Side
View
K.O. ¯ 1/4"
K.O. ¯ 1-1/8"
911 Series
90
2"
2"
Bottom View
911/912 Series
HX-912U (Flat Top)
HX-911U (Sloped Top)
How to order: Model + Heater Code with color code + Options
(example: HX-912U03000CW-1198-T1)
Density
Length
In. (mm) W/Ft W/m
Heater Code
Watts
208V
(1 ph)
Amps
240V
(1 ph)
Amps
277V
(1 ph)
Amps
Heater Code
Watts at
240/208V
240/208V
(1 ph)
Amps
500
1640
1000
01000C‡-690
4.8
01000J‡-690
4.2
01000N‡-690
3.6
1000/750
01000V‡-690
4.2/3.6
27.2 (690) 750
2450
1500
01500C‡-690
7.2
01500J‡-690
6.3
01500N‡-690
5.4
1500/1125
01500V‡-690
6.3/5.4
1000
3280
2000
02000C‡
9.6
02000J‡
8.3
02000N‡
7.2
2000/1500
02000V‡
8.3/7.2
500
1640
1500
01500C‡-944
7.2
01500J‡-944
6.3
01500N‡-944
5.4
1500/1125
01500V‡-944
6.3/5.4
37.2 (944) 750
2450
2250
02250C‡-944
10.8
02250J‡-944
9.4
02250N‡-944
8.1
2250/1690
02250V‡-944
9.4/8.1
1000
3280
3000
03000C‡
14.4
03000J‡
12.5
03000N‡
10.8
3000/2250
03000V‡
12.5/10.8
500
1640
2000
02000C‡-1198
9.6
02000J‡-1198
8.3
02000N‡-1198
7.2
2000/1500
02000V‡-1198
8.3/7.2
750
2450
3000
03000C‡-1198
14.4
03000J‡-1198
12.5
03000N‡-1198
10.8
3000/2250
03000V‡-1198 12.5/10.8
1000
3280
4000
04000C‡
19.2
04000J‡
16.7
04000N‡
14.4
4000/3000
04000V‡
16.7/14.4
500
1640
2500
02500C‡-1452
12.0
02500J‡-1452
10.4
02500N‡-1452
9.0
2500/1875
02500V‡-1452
10.4/9.0
750
2450
3750
03750C‡-1452
18.0
03750J‡-1452
15.6
03750N‡-1452
13.5
3750/2817
03750V‡-1452 15.6/13.5
1000
3280
5000
05000C‡
24.0
05000J‡
20.8
05000N‡
18.1
5000/3750
500
1640
3000
03000C‡-1655
14.4
03000J‡-1655
12.5
03000N‡-1655
10.8
3000/2250
03000V‡-1655 12.5/10.8
750
2450
4500
04500C‡-1655
21.6
04500J‡-1655
18.8
04500N‡-1655
16.2
4500/3380
04500V‡-1655 18.8/16.3
1000
3280
6000
06000C‡
28.8
06000J‡
25.0
06000N‡
21.7
6000/4500
Density
Length
In. (mm) W/Ft W/m
Watts
208V
(3 ph)
Amps
240V
(3 ph)
Amps
480V
(3 ph)
Amps
Watts at
240/208V
47.2
(1198)
57.2
(1452)
65.2
(1655)
Heater Code
05000V‡
06000V‡
Heater Code
240/208V
(3 ph)
Amps
1000
01000D‡-690
2.8
01000K‡-690
2.4
01000U‡-690
1.2
1000/750
01000P‡-690
2.8/2.1
27.2 (690) 750
2450
1500
01500D‡-690
4.2
01500K‡-690
3.6
01500U‡-690
1.8
1500/1125
01500P‡-690
3.6/3.1
1000
3280
2000
02000D‡
5.6
02000K‡
4.8
02000U‡
2.4
2000/1500
02000P‡
4.8/4.2
500
1640
1500
01500D‡-944
4.2
01500K‡-944
3.6
01500U‡-944
1.8
1500/1125
01500P‡-944
3.6/3.1
37.2 (944) 750
2450
2250
02250D‡-944
6.2
02250K‡-944
5.4
02250U‡-944
2.7
2250/1690
02250P‡-944
5.4/4.7
1000
3280
3000
03000D‡
8.3
03000K‡
7.2
03000U‡
3.6
3000/2250
03000P‡
7.2/6.2
500
1640
2000
02000D‡-1198
5.6
02000K‡-1198
4.8
02000U‡-1198
2.4
2000/1500
02000P‡-1198
4.8/4.2
750
2450
3000
03000D‡-1198
8.3
03000K‡-1198
7.2
03000U‡-1198
3.6
3000/2250
03000P‡-1198
7.2/6.2
1000
3280
4000
04000D‡
11.1
04000K‡
9.6
04000U‡
4.8
4000/3000
04000P‡
9.6/8.3
65.2
(1655)
911
(Sloped)
37
(16.8)
37
(16.8)
47
(21.3)
47
(21.3)
57
(25.9)
57
(25.9)
67
(30.4)
67
(30.4)
79
(35.8)
79
(35.8)
25.0/21.6
1640
57.2
(1452)
912
(Flat)
20.8/18.0
500
47.2
(1198)
Weight Lbs (kg)
C O N V E C T O R S
Architectural Convector
Architectural Sloped Top Convector
500
1640
2500
02500D‡-1452
6.9
02500K‡-1452
6.0
02500U‡-1452
3.0
2500/1875
02500P‡-1452
6.0/5.2
750
2450
3750
03750D‡-1452
10.4
03750K‡-1452
9.0
03750U‡-1452
4.5
3750/2817
03750P‡-1452
9.0/7.8
1000
3280
5000
05000D‡
13.9
05000K‡
12.0
05000U‡
6.0
5000/3750
05000P‡
12.0/10.4
500
1640
3000
03000D‡-1655
8.3
03000K‡-1655
7.2
03000U‡-1655
3.6
3000/2250
03000P‡-1655
7.2/6.2
750
2450
4500
04500D‡-1655
12.5
04500K‡-1655
10.8
04500U‡-1655
5.4
4500/3380
04500P‡-1655
10.8/9.4
1000
3280
6000
06000D‡
16.7
06000K‡
14.4
06000U‡
7.2
6000/4500
06000P‡
14.4/12.5
Weight Lbs (kg)
912
(Flat)
911
(Sloped)
37
(16.8)
37
(16.8)
47
(21.3)
47
(21.3)
57
(25.9)
57
(25.9)
67
(30.4)
67
(30.4)
79
79 (35.8)
(35.8)
Other voltages available, consult factory.
‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.
Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.
For three-phase units a double pole relay or thermostat is required.
91
H E A T E R S
AS
R A D I A N T
Radiant Ceiling Panels
Applications
•Atriums
•Lobbies
• Enclosed Walkways
•Offices
•Entryways
•Schools
•Hospitals
•Warehouses
AS Series radiant panels are ideal for offsetting heat
loss through exterior glass on the perimeter of a building. They help to control the problem of condensation
typically found with these large exterior glass walls.
Radiant panels provide improved comfort by maintaining an even temperature from floor to ceiling.
• R
adiant Heat: Radiant energy travels in straight
lines and is absorbed by objects in the room, warming the space. Air quality is maintained because no
forced air movement occurs with radiant heating.
• M
aximize Work Area: Ceiling mounted panels permit full use of floor and wall space.
• M
aintenance Free: Radiant panels have no moving
parts, so they are maintenance free and can provide
years of quiet, safe and clean operation.
Standard Construction
Features
Heating Element – High quality alloy resistance wire
is electrically insulated with a UL Listed TEFZEL®
compound rated for 200°C (392°F). Heating wires
are covered with high-efficiency reflective foil.
Panel Design – Panel is made of 22-gauge galva-
nized steel with a white baked-on powder paint finish.
Panel is crimped, not riveted, for improved strength.
Insulation – Each panel contains two inches of high
temperature/high density mineral wool insulation.
Electrical – A junction box is attached to each panel
for field wiring and to connect panels to each other.
92
Installation Requirements – Heater can be installed
in suspended T-bar ceiling systems or can be surface
or recessed mounted using optional mounting frames.
Heater comes equipped with four suspension clips.
Connecting wire or chain is supplied by customer.
Minimum recommended mounting height is eight feet
from the floor.
Rough In Dimensions –
Plaster Mounting Frames:
• PF-22: 24-1/8” x 24-1/8”
• PF-24 and SPF 24: 24-1/8” x 48-1/8”
• PF-1448: 14-18” x 48-1/8”
• PF-1460: 14-1/8” x 60-1/8”
AS
Factory Built-in Options
Description
Code
S
Silicone seams, provides protection in high moisture areas. Includes 36” of sealtite conduit.
TEG
Tegular reveal edge detail for 15/16” grid.
TEGF
Fineline Tegular reveal edge for 9/16” grid.
Width
Length
Weight
Catalog
In. (mm)
In. (mm)
lb (kg)
Number
Surface Mounting Frames
SF-22
24 (610)
24 (610)
4 (1.8)
SF-24
24 (610)
48 (1219)
9 (4.1)
SF-1448
14 (356)
48 (1219)
8 (3.6)
SF-1460
14 (356)
60 (1524)
10 (4.5)
Plaster Mounting Frames
Finishes
Description
Code
O
Specify custom color finish.
PT
Standard finish; textured white baked-on powder
coating on front panel.
S304
304 Stainless steel construction, includes
36” of sealtite conduit and silicone seal.
S316
316 Stainless steel construction, includes
36” of sealtite conduit and silicone seal.
SS
(shipped loose for field installation into heater)
Silk screen to match acoustical ceiling tiles
(specify style).
PF-22
24 (610)
24 (610)
2 (1.0)
PF-24
24 (610)
48 (1219)
4 (1.8)
SPF-24(1)
24 (610)
48 (1219)
4 (1.8)
PF-1448
14 (356)
48 (1219)
5 (2.3)
PF-1460
14 (356)
60 (1524)
6 (2.7)
H E A T E R S
FCXX
Flexible electrical conduit.
Specify length of conduit XX-inches.
Field-Installed Options
R A D I A N T
Radiant Ceiling Panels
Filler Panel
FP
Sized and finished to match standard, custom color or silk screened panel.
(1) Stainless steel frame, specify 304 or 316 type.
Add finish code to end of catalog number.
One time set-up fee if pattern is not in stock.
Control Options
Catalog
Number
Remote Room Thermostat – See page 98
Description
SR-LV
SmartRooms low voltage controller. Sensor(s)
must be ordered at the same time. Requires
connection to SmartRooms Communication
Panel.
PL-1
Plaster ring for SR-LV Controller
BX-1
Box ring for SR-240/120 Controller
Sensors
Used with SR-240/120, 15’ long
Longer length add per foot
SRDP-10/10
SmartRooms Panel w/10comm. Ports and 10 ea.
20 amp relays
SRDP-10/20
SmartRooms Panel w/10comm. Ports and 20 ea.
20 amp relays
SRDP-20/20
SmartRooms Panel w/20comm. Ports and 20 ea.
20 amp relays
93
H E A T E R S
AS
Radiant Ceiling Panels
Wire Suspended
Flush Mounting Kit
R A D I A N T
FlushFlus
Mount
Frame
h M ountFram e
in Drywall
Ceiling
in Dryw all
Ceili
ng
Nail
Nail
Ceiling
Ceili
ng Joist
Jo
ist
Ceiling
Joist
Cei
ling
Joist
Radiant
Heater
Radiant
eat
H er
Each Kit Includes:
Each Kit Includes:
22- Side
Pieces
- Side
ieces
P
22- End
Pieces
- End
es
Piec
44- Corner
- Cor
nerBrackets
Br
ackets
Junction
Juncti
onBox
Bo
x
4”4"
x 4”xx 4"
1-1/2”
1-1/2"
Nai
Naill
2”2"
2”
Flush
Flu
shMounting
Moun
tingFrame
ame
Fr
Factory
Factor
y Painted
Pain
ted24
24Gauge
Gauge
Extruded
Extr
udedAluminum
Aluminum
2"
1-1/2”
1-1/2"
Plaster
Frame
Pla
ster
rame
F
Flush
Kit
Flu
shMount
Moun
t Kit
Finished
Ceiling
Fin
ished
Ceiling
Pow er Supply
Suppl
y
Power
Ceiling
Jois
t
Ceiling
Joist
Each Kit
Includes: :
Each Kit Includes
2 - Side
2 Channels
- Side
hannels
C
- End Channels
2 - End2 Channels
4 CornerB
rackets
4 - Corner
Brackets
with
rews Sc
with screws
Ceilin
g
Ceiling
4"
Toggl
e Bol
t
Toggle
Bolt
CornerMoun
tin
g
Corner
Mounting
Bracket withrews
Sc
2"
Bracket with Screws
Surfa
ce Mounting
Fr
am e
Surface
Mounting
Frame
Factory Pain
ted 12
Gage
Factory Painted
12
Gal
vani
zed Gage
Steel
Galvanized Steel
4” x 4”
4" xX1-1/2”
4" X 1-1/2"
Junction ox
B
Junction
Box
Radia
ntHeater
Radiant
Heater
Surface
Mountin
g
Surface
Mounting
2”,
4 Lb4Density
2",
Lb
ensity
D
High
Temperature
Mineral
High
Temp
erature
ineral
M
Wool
Woo lInsulation
Insulation
Support
Clips
Support
lips
C
Reflectiv
Reflective
Foile
Foi
l
High
Density
High
Densit
y
Heating
Panel
Heating
Panel
4”4"
x 4”Xx 1-1/2”
4" X 1-1/2"
Junction
Juncti
onBoxBo
x
With
Cover
with
Co
ver
2”
2"
B
Height
94
A
Width
Electric
Heating
Element
Ele
ctr
ic Hea
ting
- Alloy
Ele
mentWire,
-lloy
ATefzel
ire
W,
Insulation
Tef
zelInsulation
2222
Gauge
Galvanized
Gauge
Galv
anized
Steel
Front
Steel
ont
Frandan
dBack
Back
ofof
UnitUnit
Factory
Finished
Factor
y
Finished with
with
a High Temp
Temperature,
a High
erature
,
Textured
Powder
Textured
owder
P Paint
Pain
t
Finish
Fin
ish
Cutaway
View of View
AS Seriesof
Heater
Cutaway
AS S
erieseat
Her
AS
AS - Radiant Ceiling Panels Listing
Watts
Width
In. (mm)
Height
In. (mm)
Amps
Weight
lb (kg)
Catalog
Number
120
208
240
277
120
208
240
277
240
120
120
277
208
120
208
277
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
2.1
1.2
1.0
0.9
2.6
1.5
1.3
1.1
1.4
2.8
2.8
1.2
1.7
3.1
1.8
1.4
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
HX-AS2424-250-120
HX-AS2424-250-208
HX-AS2424-250-240
HX-AS2424-250-277
HX-AS2424-310-120
HX-AS2424-310-208
HX-AS2424-310-240
HX-AS2424-310-277
HX-AS2424-325-240
HX-AS2424-335-120
HX-AS2424-335-120
HX-AS2424-335-277
HX-AS2424-355-208
HX-AS2424-375-120
HX-AS2424-375-208
HX-AS2424-375-277
120
240
277
208
208
120
208
240
277
208
240
120
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
4.2
2.1
1.8
2.5
2.6
5.2
3.0
2.6
2.4
3.4
3.0
6.3
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
30 (13.6)
HX-AS2448-500-120
HX-AS2448-500-240
HX-AS2448-500-277
HX-AS2448-515-208
HX-AS2448-535-208
HX-AS2448-625-120
HX-AS2448-625-208
HX-AS2448-625-240
HX-AS2448-675-277
HX-AS2448-715-208
HX-AS2448-725-240
HX-AS2448-750-120
240
120
277
208
208
240
277
14 (356)
14 (356)
14 (356)
14 (356)
14 (356)
14 (356)
14 (356)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
48 (1219)
1.3
2.9
1.3
1.9
2.1
1.8
1.6
18 (8.2)
18 (8.2)
18 (8.2)
18 (8.2)
18 (8.2)
18 (8.2)
18 (8.2)
HX-AS1448-300-240
HX-AS1448-350-120
HX-AS1448-350-277
HX-AS1448-400-208
HX-AS1448-435-208
HX-AS1448-435-240
HX-AS1448-435-277
120
240
277
208
277
240
14 (356)
14 (356)
14 (356)
14 (356)
14 (356)
14 (356)
60 (1524)
60 (1524)
60 (1524)
60 (1524)
60 (1524)
60 (1524)
2.9
1.6
1.4
2.2
1.9
2.3
22 (10.0)
22 (10.0)
22 (10.0)
22 (10.0)
22 (10.0)
22 (10.0)
HX-AS1460-350-120
HX-AS1460-375-240
HX-AS1460-375-277
HX-AS1460-450-208
HX-AS1460-535-277
HX-AS1460-550-240
H E A T E R S
24 x 24
250
250
250
250
310
310
310
310
325
335
335
335
355
375
375
375
24 x 48
500
500
500
515
535
625
625
625
675
715
725
750
14 x 48
300
350
350
400
435
435
435
14 x 60
350
375
375
450
535
550
Volts
(1 Phase)
R A D I A N T
Radiant Ceiling Panels
Add finish code to end of catalog number. See page 93.
95
H E A T E R S
Cove
R A D I A N T
Cove Heater
Applications
•Classrooms
•Lobbies
•Garages
•Offices
• Hospital Rooms
•Restrooms
Cove heaters are designed to supply efficient radiant
heat. They provide greater comfort at lower temperature settings and can be set up for individual or zone
control to reduce energy costs.
• Radiant Heat: Radiant energy travels in a straight
line from the heater to people and objects in the
room, warming the space.
• Convection Flow: The design of the heater provides
a convection flow from behind and over the top of the
unit to circulate warm air into the room.
• Virtually Maintenance Free: No moving parts to
replace or service.
• Exclusive Tilt and Lock Mounting System: Allows
easy, one-person installation.
Standard Construction Features
Heating Element – Commercial grade tubular heating ele-
Installation Requirements – Minimum clearances: Six
ment.
feet from the floor; 2-1/2 inches from plaster ceilings or
4-1/2 inches from false ceilings, vinyl ceilings and plaster
moldings.
Housing – Heater has an 18-gauge G-90 galvanized
steel frame. The continuous single-piece construction
and solid metal end caps provide durability.
Front Panel – Heavy gauge aluminum front panel finished
with an off-white high emissivity coating. Other standard
finishes include walnut, sandalwood, light almond and
pure white.
Electrical – Ventilated junction boxes at each end of
the heater with one-half inch electrical knockouts.
High temperature (125°C) 12-gauge cross link wiring is
used through out the heater.
96
Maintain one inch below heater and any fabric.
Allow one-inch clearance between adjacent heaters.
COVE
Standard Finishes
Finish
Availability
Off-White
OW
Standard
Walnut
WL
Stock
Sandalwood
SW
Stock
Light Almond
AL
Stock
Pure White
PW
Stock
H E A T E R S
Code
R A D I A N T
Cove Heater
To Specify Finish: Choose code from above.
Example: C-4524-OW = Off-White Unit
Remote Room Thermostat – See page 98
Cove Heater Listing
Watts
450
600
750
900
1050
1200
1500
1800
2000
Volts
(1 Phase)
Amps
Length
In. (mm)
120
208
240
277
120
208
240
277
120
208
240
277
120
208
240
277
120
208
240
277
120
208
240
277
208
240
277
208
240
277
208
240
277
3.7
2.2
1.9
1.6
5
2.9
2.5
2.2
6.2
3.6
3.1
2.7
7.5
1.3
3.7
3.2
8.8
5
4.4
3.8
10
5.8
5
4.3
7.2
6.2
5.4
8.7
7.5
6.5
9.6
8.3
7.2
34 (864)
34 (864)
34 (864)
34 (864)
47 (1194)
47 (1194)
47 (1194)
47 (1194)
59 (1499)
59 (1499)
59 (1499)
59 (1499)
71 (1803)
71 (1803)
71 (1803)
71 (1803)
83 (2108)
83 (2108)
83 (2108)
83 (2108)
94 (2388)
94 (2388)
94 (2388)
94 (2388)
106-1/4 (2699)
106-1/4 (2699)
106-1/4 (2699)
118-1/4 (3004)
118-1/4 (3004)
118-1/4 (3004)
132 (3353)
132 (3353)
132 (3353)
Add finish code to end of catalog number.
Weight
lb (kg)
6 (2.7)
6 (2.7)
6 (2.7)
6 (2.7)
8 (3.6)
8 (3.6)
8 (3.6)
8 (3.6)
10 (4.5)
10 (4.5)
10 (4.5)
10 (4.5)
12 (5.4)
12 (5.4)
12 (5.4)
12 (5.4)
13 (5.9)
13 (5.9)
13 (5.9)
13 (5.9)
15 (6.8)
15 (6.8)
15 (6.8)
15 (6.8)
18 (8.2)
18 (8.2)
18 (8.2)
20 (9.1)
20 (9.1)
20 (9.1)
22 (10)
22 (10)
22 (10)
Catalog
Number
HX-C-4512
HX-C-4508
HX-C-4524
HX-C-4527
HX-C-6012
HX-C-6008
HX-C-6024
HX-C-6027
HX-C-7512
HX-C-7508
HX-C-7524
HX-C-7527
HX-C-9012
HX-C-9008
HX-C-9024
HX-C-9027
HX-C-10512
HX-C-10508
HX-C-10524
HX-C-10527
HX-C-12012
HX-C-12008
HX-C-12024
HX-C-12027
HX-C-15008
HX-C-15024
HX-C-15027
HX-C-18008
HX-C-18024
HX-C-18027
HX-C-20008
HX-C-20024
HX-C-20027
97
T H E R M O S T A T S
THERMOSTATS
1006998
901-1006998
901-1007030
1007030
901-OTH550BL
901-OTH507
901-OTH660
901-OTH607
901-1016941
1004328
901-124644
901-OTH800D
901-OTH824
901-124645
901-RC840
901-RC840T-240
901-RC840T-277
1007002
901-124640
901-124641
SR-240/120(4)
901-RT850
901-RT850T-240
1007014
901-124642
901-124643
Line Voltage Thermostats for 240 Series Heaters (Pages 29-32)
Catalog
Number
Switch
Type
Color
Type
1007014
Bimetal
White
SPDT
Tamper- Thermo- Amps @ Amps @
proof
meter 120-240V 277V
No
No
22
19
Pilot
Duty
Positive Temperature
Off
Range °F
—
—
40-80
Low Voltage Thermostats for Industrial Unit Heater 238 Series (Pages 26-28)
1006998
Bimetal
White
SPDT
No
No
—
—
30VA at
30V max
Yes
50-90
1007030
2-stage
Bimetal
White
2 SPST
Switches
No
Yes
—
—
30VA at
30V max
Yes
40-90
—
—
41-95
—
No
40-85
—
Yes
40-85
Thermostats for AS Series Radiant Ceiling Panels (Pages 92-95)
SR-240/120(4) Electronic
R-101
R-102
Bimetal
White
Beige
DPDT
No
Digital
SPST
No
No
DPST
No
No
16A @
120&240V
—
22
18
(4) A 3 inch deep double electrical box will be supplied for wall installation. Remote window sensor option is available, contact factory for pricing.
Thermostats for Cove Heaters (Pages 96-97)
R-101
R-102
Bimetal
Beige
SPST
No
No
DPST
No
No
22
18
—
No
40-85
—
Yes
40-85
Explosion-proof Heaters - Remote Wall Mounted Thermostat (Pages 8-21)
Catalog
Number
Switch
Type
Ratings
Type
1007002
Bimetal
Class I, Div 1 Group C&D,
Class II, Div 1 Group E,F&G
NEMA 7
SPDT
Tamper- Thermo- Amps @
proof
meter 125-277V
No
No
22
Pilot
Duty
Temperature
Range
°F (°C)
—
50-90
(10-32)
Washdown/Corrosion Resistant 234 Series Unit Heater Remote Wall Mounted Thermostat (Pages 23-25)
98
Catalog
Number
Switch
Type
Ratings
Type
Tamperproof
Thermometer
Amps
Pilot
Duty
Temperature
Range
°F (°C)
1004328
Bulb
NEMA 4X
SPDT
No
No
25A @ 120-240V
22A @ 277V
125VA
40-110F
(4-43)
THERMOSTATS
Catalog
Number
Switch
Type
Color
Type
901-124640
901-124642
901-124643
Bimetal
Beige
Bimetal
White
SPST
SPST
DPST
901-OTH800D(1)
White
901-OTH550(1)(3)
(3)
Electronic
901-OTH507(1)
White
901-OTH660(2)(3)
(3)
Tamper- Thermo- Amps @ Amps @ Pilot Positive
proof
meter 120-240V 277V
Duty
Off
No
No
22
19
—
­­
No
No
22
19
—
15A @
208&240
—
—
16
—
—
—
16
—
DPST
Pulse
Yes
Digital
16
Pulse or
White On-Off
901-OTH607(2)
No
No
Yes
No
Temperature
Range oF
40-80
40-80
40-85
T H E R M O S T A T S
Line Voltage Thermostats for 900 Series Heaters (Pages 39-91)
—
—
16
—
(1) Do not use these thermostats with heaters that have inductive loads (heaters that have a motor or contactor).
(2) Programmable electronic thermostat. Recommended for heaters with motor or contactor.
(3) Add to catalog number W - white or A - almond color.
Low Voltage Thermostats for 900 Series Heaters (Pages 33-91)
Catalog
Number
Switch
Type
Tamper- Thermo- Amps @ Amps @
proof meter 120-240V 277V
Pilot
Duty
Positive
Off
Temperature
Range oF
—
30VA at
30V max
Yes
50-90
—
—
36VA at
30V max
No
45-95
—
—
30VA at
30V max
Yes
40-90
Color
Type
901-1006998
Bimetal White
SPST
No
No
—
901-219981
Precision
Snap White
Action
SPST
No
No
No
Yes
901-1007030 (3)
2-stage
2 SPST
White
Bimetal
Switches
(3) 2-Stage room thermostat for use with 922 Series Cabinet Unit Heater.
Low Voltage Electronic Thermostats for 900 Series Heaters (Pages 69-91)
Catalog
Number
Switch
Type
Tamper- Thermo- Amps @
proof meter 120-240V
Amps @
277V
Color
Type
901-1016941 Electronic Beige
DC
Pulse
No
No
—
—
901-OTH824 Electronic White Pulse
Yes
Digital
—
—
Output Positive Temperature
Signal
Off
Range oF
20mA
Max at
8 VDC
24VAC
No
50-90
No
40-85
Amps@
120-240V
Amps@
277V
Input
Signal
23
23
23
22
22
—
—
18
—
18
(1) Do not use these thermostats with heaters that have inductive loads (heaters that have a motor or contactor).
Controllers and Accessories for 900 Series Heaters (Pages 33-91)
Catalog
Number
Description
Triac Relay without transformer
(pulsing) 120/208/240/277 V
901-RT850T-240 Triac Relay with transformer 208/240 V
901-RC840
On-Off Relay without transformer 120/208/240/277 V
901-RC840T-240 On-Off Relay with transformer 208/240 V
901-RC840T-277 On-Off Relay with transformer 277 V
901-RT850
24VAC &
4-32 VDC
24 VAC
—
—
—
Accessories for 900 Series Heaters (Pages 33-91)
Catalog
Number
Description
901-124644
UniversalThermostatGuard.Protectsbothlineandlowvoltagethermostatsagainstvandalism,damage,and
unauthorized adjustment of thermostat settings.
99
W A R R A N T Y
L I M I T E D
Limited Warranty
HEATREX new products are warranted against defects in workmanship, material, design, labeling and packaging. No other warranty, expressed or implied, written or oral, applies. No person other than an officer or
the general manager of HEATREX is authorized to give any other warranty or assume any liability.
Warranty Period
This warranty is effective for eighteen months from the date of shipment of the product from HEATREX’s factory, or for twelve months from the date the product is first placed into service, whichever period lapses first.
Conditions of Warranty
HEATREX products must be installed, operated, and maintained in accordance with HEATREX’s instructions. HEATREX is not liable for damage or unsatisfactory performance of the product resulting from accident, negligence, alteration, unauthorized repair, improper application or installation of the product, improper
specifications, or corrosion. HEATREX IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES. Claims against carriers for damage in transit must be filed by the purchaser with the carrier.
Remedy
Contact the HEATREX sales department in St. Louis at (314) 333-5500, for a Return Material Authorization Number (RMA#). Return the part or product in question, freight prepaid, and marked with your company
name and the RMA# to:
HEATREX
425 Hanley Industrial Court
St. Louis, MO 63144
Attn: Return Materials Manager
If after receipt of the product and the claim, HEATREX finds to its reasonable satisfaction that the product is
defective in workmanship, material, design, labeling or packaging, the product will be repaired or replaced,
or the purchase price refunded at HEATREX’s option. There will be no charge to the purchaser for parts
or labor. Removal and reinstallation of the product, and shipment of the product to HEATREX for repair or
inspection, shall be at the purchaser’s risk and expense.
THE REPAIR, REPLACEMENT, OR REFUND PROVIDED FOR IN THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER,
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE TERMS OF THIS LIMITED WARRANTY.
100
INTRODUCTION
HEATREX offers commercial and industrial electric heating
and control systems that set the industry standard for excellence. The company’s heating solutions reflect more than 80
years of innovation, product quality and efficient service.
This catalog features HEATREX’s complete
Space Heating line. Our products include
Explosion-proof an explosion-proof convector; the Washdown/Corrosion Resistant Unit
Heater; and several types of standard unit
heaters.
HEATREX’s line of Comfort Heating
Products cover a wide range of commercial
and industrial applications. Whether the
requirement is for architectural wall heaters,
cabinet unit heaters, convector heaters or
ceiling heaters, HEATREX has a product to
match the application.
HEATREX’s quality is matched only by its
customer service and support. With its quick-ship delivery
program, HEATREX provides the products you need.
Color Selection Chart
Standard Colors 900 Series
White
(W)
Standard Color 240 Series
Almond
(A)
Special Colors 900 Series
Camel
Optional Colors 240 Series
Metallic Silver
(AE)
Beige-Grey
(BG)
Grey
Yellow
Metallic Charcoal
(CM)
Bronze
(BZ)
Red
White
Textured Black
(NR)
Aluminum
(AL)
Blue
Textured Beige
Refer to catalog listings for standard and special color availability. Use color codes in
parentheses when specifying and ordering. Custom colors are also available on 900
Series. Special and Optional Colors subject to setup charges. Colors represented are
approximate.
electric
heating products
explosion-proof unit
heater
wall heater
ceiling heater
explosion-proof convector
washdown/corrosion
resistant unit heater
industrial unit heater
unit heater
convector heater
cabinet heater
baseboard heater
wall heater
radiant panel
commercial & industrial
For Limited Warranty Information contact:
HEATREX
425 HANLEY INDUSTRIAL COURT
ST. LOUIS, MO 63144
314-333-5500
www.heatrex.com
90-1000-80-1
5M0610
electric heating and controls
Download