electric heating products explosion-proof unit heater wall heater ceiling heater explosion-proof convector washdown/corrosion resistant unit heater industrial unit heater unit heater convector heater cabinet heater baseboard heater wall heater radiant panel commercial & industrial For Limited Warranty Information contact: HEATREX 425 HANLEY INDUSTRIAL COURT ST. LOUIS, MO 63144 314-333-5500 www.heatrex.com 90-1000-80-1 5M0610 electric heating and controls INTRODUCTION HEATREX offers commercial and industrial electric heating and control systems that set the industry standard for excellence. The company’s heating solutions reflect more than 80 years of innovation, product quality and efficient service. This catalog features HEATREX’s complete Space Heating line. Our products include Explosion-proof an explosion-proof convector; the Washdown/Corrosion Resistant Unit Heater; and several types of standard unit heaters. HEATREX’s line of Comfort Heating Products cover a wide range of commercial and industrial applications. Whether the requirement is for architectural wall heaters, cabinet unit heaters, convector heaters or ceiling heaters, HEATREX has a product to match the application. HEATREX’s quality is matched only by its customer service and support. With its quick-ship delivery program, HEATREX provides the products you need. Color Selection Chart Standard Colors 900 Series White (W) Standard Color 240 Series Almond (A) Special Colors 900 Series Camel Optional Colors 240 Series Metallic Silver (AE) Beige-Grey (BG) Grey Yellow Metallic Charcoal (CM) Bronze (BZ) Red White Textured Black (NR) Aluminum (AL) Blue Textured Beige Refer to catalog listings for standard and special color availability. Use color codes in parentheses when specifying and ordering. Custom colors are also available on 900 Series. Special and Optional Colors subject to setup charges. Colors represented are approximate. Table of Contents Advantages/Applications 2 Use of Electric Heaters in Hazardous Locations 3-5 Comparison Chart 6-7 Explosion-proof Unit Heaters 233 Series Explosion-proof Unit Heaters 922 Series Cabinet Unit Heater 56-59 936/937 Series Commercial Ceiling Heater 60-63 931 Series Commercial Ceiling Heater 64-65 8-14 236 Series Compact Explosion-proof Unit Heaters 15-17 254 Series Convector 18-21 928 Series Toe-Space Heater 66 939 Series Floor Insert Heater 67 Baseboard and Convector Heaters Comparison Chart 68 Fan Forced Heaters Comparison Chart 22 234 Series Washdown/Corrosion Resistant Unit Heaters 23-25 238 Series Industrial Unit Heater 26-28 240 Series Unit Heater 29-32 926 Series Unit Heater 33-35 924 Series Economical Unit Heater 928 Series Vertical Unit Heater 927 Series Portable Heater 902 Series Commercial Baseboard Heater 69-71 904/906 Series Architectural Sill-Height Convector 72-74 905/907 Series Industrial Sill-Height Convector 75-77 908/909 Series Architectural Convector 78-80 914 Series Mini Draft Barrier Heater 82-84 916 Series High Watt Density Draft Barrier Heater 85-87 911/912 Series Architectural Cabinet Convector 88-91 37 38-40 41 Wall, Ceiling and Floor Heaters Comparison Chart 42-43 933 Series Architectural Wall Heater 44-46 932 Series Commercial Wall Heater 47-49 935 Series European Wall Heater 50 940 Series Hybrid Convection & ForcedAir Wall Heater 51 934 Series Wall Heater 52-53 930 Series Register Wall Heater 54-55 Radiant Panels AS Series 92-95 Cove Heater 96-97 Thermostats Limited Warranty Color Section Chart 98-99 100 Inside Back Cover 1 Advantages/Applications ® Experience This catalog represents 80 years of experience in industrial electric heating – our specialty since HEATREX was founded in 1929. HEATREX has been manufacturing products for use in hazardous locations for over 55 years. Complete Product Line HEATREX offers the industry’s most comprehensive line of space heating equipment. Explosion-proof unit heaters are available with ratings up to 30 kW and 600 volts. 234 Series unit heaters provide heat in nonhazardous environments where moisture and corrosion are present. Standard unit heaters include a heavy duty industrial model, several commercial models, vertical, cabinet and portable designs. A wide range of floor, wall and ceiling heaters, including baseboard heaters and radiant ceiling panels, are available to meet any application requirement. HEATREX also offers the widest selection of built-in controls in the industry. Quick Delivery A wide selection of assembly stock designs with options are available in two weeks. Most comfort heating products will ship in two weeks. Colors American Bureau of Shipping Many of HEATREX’s comfort heating products are available in a choice of colors. Standard and special colors are shown in the back of this catalog. Custom colors, including bronze or clear anodizing and matches to customer supplied paint samples, are also available on select heaters. Safety HEATREX explosion-proof unit heaters are Factory Mutual (FM) Approved and include redundant overtemperature protection which exceeds agency requirements. The 233 Series unit heater has the industry’s lowest Ignition Temperature Code rating, 320°F (160°C), and is also CSA Approved. HEATREX corrosion resistant heaters are available with cULus Approvals. Explosion-proof and corrosion resistant heater designs are available for marine and shipboard use that are ABS Approved and meet U.S. Coast Guard requirements. HEATREX commercial and industrial unit heaters are UL and cUL Approved for non-hazardous, non-corrosive environments. Comfort heating products are CSAus or CSA Approved. Hazardous and Corrosive Area Applications • Aircraft Hangars/Service Areas • Battery Storage Areas • Chemical Plants • Chemical Storage/Handling Areas • Coal Mines/Preparation Plants • Control Rooms • Dry Cleaning Plants • Dusty Areas Subject to Washdown • Food Processing Plants (Washdown Areas) • Foundries • Gasoline Fueling/Storage Areas • Grain Elevators • Hydrogen Atmospheres • Marine/Shipboard and Landbase Facilities • Natural Gas (Methane) Atmospheres • Oil Refineries • Offshore Drilling Rigs • Paint Spraying/Storage Areas • Parking Garages • Petrochemical Plants • Pipeline Pumping Stations • Pulp and Paper Mills • Sewage/Wastewater Treatment Plants • Solvent Recovery/ Storage Areas • Utility Plants Industrial and Commercial Applications • Basements • Classrooms • Conference Rooms • Entryways/Hallways • Factories • Lobbies 2 • Mechanical Rooms • Offices • Power Generating Stations • Pump Houses • Restrooms • Service Stations/Garages • Shipping and Receiving Areas • Stairwells • Storage Areas • Vestibules • Warehouses • Workshops Use of Electric Heaters In Hazardous Locations Introduction Hazardous locations are those areas where a potential for explosion and fire exists due to the presence of flammable gases, vapors, pulverized dusts or ignitable fibers in the atmosphere. Hazardous locations are created from the normal processing of volatile chemicals, gases, coal, grains, etc., or from the accidental failure of storage systems for these materials. Open flames are not permitted in these locations. The use of electric heating equipment is permitted with two major restrictions: 1) The surface temperature of the equipment cannot exceed the ignition temperature of the hazardous atmosphere and 2) all arc and spark producing devices must be isolated from the atmosphere in an appropriate enclosure. Both people and equipment in hazardous locations can be heated safely and economically with electric heat. Electric heating is typically much less expensive to install and maintain than comparable remote oil or gas fired heating systems. National Electrical Code Classification Articles 500 through 516 of the National Electrical Code deal with the definition of hazardous areas and the use or design of electrical equipment used in these locations. Electric heating equipment for hazardous areas is specified based on the NEC class, division, group and ignition temperature or the alternate class and zone classification. Class in the atmosphere. Typical locations would include coal fired power plants, coal preparation/coal handling facilities, coal mines, grain elevators, flour and feed mills, packaging and handling of pulverized sugar and processing and storage of magnesium and aluminum powder. Class III – This third classification is primarily a fire hazard where fibers or flyings suspended in the air create a hazard. This would include small pieces of thread-like fiber, sawdust, lint, etc. Typical applications would include textile mills, woodworking plants, cotton gins, cotton seed mills and flax producing plants. Division Class I, Class II and Class III areas are further defined in terms of when the hazard occurs. Division 1 and Division 2 occurrences are summarized below. Division 1 – If the hazard is expected to be present under normal conditions, such as a production or processing facility, the occurrence is designated Division 1. The hazardous atmosphere may be present continuously, intermittently, periodically, or during normal repair or maintenance operations. Division 1 occurrences also include locations where a breakdown in the operation of processing equipment results in the release of hazardous vapors. Division 2 – If the hazardous material is normally expected to be contained within a closed area, system or container, and would enter the ambient atmosphere only under an abnormal failure, then it is referred to as a Division 2 occurrence. Hazardous locations are divided into the three general classes of vapors/gases, dusts and fibers. Class I – Locations where the potential for explosion and fire exists due to the presence of flammable gases or vapors in the air. Typical Class I locations include oil or natural gas drilling rigs, petroleum refining or pumping facilities, petrochemical plants, wastewater/sewage treatment plants, solvent extraction plants, paint spraying booths, locations where open tanks or vats of combustible liquids are present and storage areas for flammable materials. Class II – Locations where the potential for explosion exists because of finely pulverized flammable dusts suspended 3 Use of Electric Heaters In Hazardous Locations Group The nature and explosive characteristics of the hazardous material are defined by the NEC group to which it is assigned. Class I – Hazardous vapors/gas locations include chemicals and other materials that have been divided into four groups based on their ignition temperature and explosive characteristics. (Groups A, B, C and D) Class II – Hazardous dust locations are divided into three groups based on their ignition temperature and electrical conductivity of the suspended particles. Group E – Atmospheres containing metal dust, such as aluminum or magnesium. Group F – Atmospheres containing coal, charcoal or coke dust. Group G – Atmospheres with grain, flour, starch, combustible plastics or chemical dust. Class III – Locations have no group definitions. Class I, Zone 1 – Locations in which ignitable concentrations of flammable gases or vapors are likely to exist, may exist frequently or exist as a result of equipment breakdown or faulty operation. Applies to locations adjacent to a Class I, Zone 0 location. Class I, Zone 2 – Locations in which ignitable concentrations of flammable gases or vapors are not likely to occur under normal operation, exist only for a short period or exist only as a result of accidental failure, such as rupture or breakdown of the container or system, abnormal operation of equipment, failure or abnormal operation of the ventilation equipment. Applies to locations adjacent to a Class I, Zone 1 location. Material Groups Group IIC – Atmospheres containing acetylene or hydrogen. Equivalent to a combination of Class I, Group A and Class I, Group B as described in NEC Article 500. Class and Zone Classifications Group IIB – Atmospheres containing acetaldehyde. Equivalent to Class I, Group C as described in NEC Article 500. Ignition Temperature Group IIA – Atmospheres containing acetone, ammonia, ethyl alcohol, gasoline, methane or propane. Equivalent to Class I, Group D as described in NEC Article 500. All electrical equipment is designed not to exceed the ignition temperature of the hazardous atmosphere. The maximum surface temperature for electric heaters is defined by the NEC. Maximum Surface Temperature of Heater 4 Class I, Zone 0 – Locations in which ignitable concentrations of flammable gases or vapors are present continuously or for long periods. °F °C NEC Ignition Temperature Code 842 450 T1 572 300 T2 536 280 T2A 500 260 T2B 446 230 T2C 419 215 T2D 392 200 T3 356 180 T3A 329 165 T3B Use of Electric Heaters In Hazardous Locations Special Requirements for Electric Heating Equipment used in Hazardous Areas Electric heating equipment can be economically designed and safely used in hazardous areas if the following special requirements are observed. 1. The surface temperature of the electric heating equipment cannot exceed the ignition temperature of the hazardous atmosphere. To insure that the proper heater has been selected, it is essential that the correct NEC Ignition Temperature Code be specified. If the temperature code selected is too high, the electric heating system may operate above the ignition point of the application, creating a potentially hazardous condition. CLASS I - HAZARDOUS GAS ATMOSPHERES NEC Material °F °C A Acetylene 581 305 T2 B Acrolein (Inhibited) 428 220 T2D Butadiene Ethylene Oxide Hydrogen Propylene Oxide Propyl Nitrate 788 804 932 840 347 420 429 500 449 175 Acetaldehyde 347 175 713 1128 928 842 1000 500 802 610 378 609 498 450 538 260 428 321 C Allyl Alcohol Carbon Monoxide Cyclopropane Ethylene Hydrogen Cyanide Hydrogen Sulfide 2-Nitropropane Tetrahydrofuran D Code 867 463 465 651 Benzene 928 498 T1 Butane 550 287 T2A 1-Butanol (Butyl Alcohol) 2-Butanol (Secondary Butyl Alcohol) Ethane Ethanol (Ethyl Alcohol) Ethyl Acetate Ethylene Dichloride Gasoline (56-60 Octane) Gasoline (100 Octane) Heptanes Hexanes Isoprene Isopropyl Ether Methane (Natural Gas) 650 761 343 405 882 685 800 775 536 853 399 437 428 830 9001170 867 662 472 363 427 413 280 456 204 235 220 443 482632 454 350 759 404 Methanol (Methyl Alcohol) 3-Methyl-1-Butanol (Isoamyl Alcohol) Methyl Ethyl Ketone The materials given are found in NFPA 497, 1991 and NFPA 325, 2001. Ignition Temp. Group D T3B 869 1204 Acetic Acid (Glacia) Acetone Ammonia, Anhydrous 3. All electrical supply connections must be made according to the latest NEC and local code requirements for hazardous locations. This includes the requirement that conduit entering the enclosures must be provided with seals at the enclosure. CLASS I - HAZARDOUS GAS ATMOSPHERES Ignition Temp. Group 2. All arc and spark-producing control devices must be isolated from the hazardous atmosphere. If it is not economically feasible to locate the control devices in the non-hazardous area, they must be housed in an enclosure that will withstand the pressure of a potential explosion from within the enclosure. T1 Material NEC °F °C Code Methyl Isobutyl Ketone 840 448 T2 2-Methyl-1-Propanol 780 415 T2 (Isobutyl Alcohol) Petroleum Naptha Pyridine Octanes Pentanes 550 900 403 500 288 482 206 260 T2A T1 T3 T2B 1-Pentanol (Amyl Alchohol) 650 343 T2 Propane 1-Propanol (Propyl Alchohol) 2-Propanol (Isopropyl Alcohol) Propylene Styrene Toluene Vinyl Acetate Vinyl Chloride 842 775 750 851 914 896 756 882 450 412 399 455 490 480 402 472 T1 T2 T2 T1 T1 T1 T2 T1 Xylenes 867- 463- T1 984 528 CLASS II - HAZARDOUS DUST ATMOSPHERES Group Material E Aluminum, A422 Flake Calcium Silicide Manganese Magnesium, Grade B, Milled F Charcoal Coal, Kentucky Bituminous Coal, Pittsburgh Experimental Pitch, Petroleum G Alkyl Ketone Dimer Sizing Compound Corn Corn Starch, Modified Polyurethane Foam, Fire Retardant Shellac Soy Flour Sugar, Powdered Sulfur Wheat Wood Flour Ignition Temp. NEC Code °F °C 608 1004 464 806 356 356 338 1166 320 320 540 240 430 180 180 170 630 160 T2 T1 T2C T2 T3A T3A T3B T1 T3C 482 392 734 250 200 390 T2C T3 T2 752 374 698 428 428 500 400 190 370 220 220 260 T2 T3A T2 T2D T2D T2B 5 H E A T E R S Comparison Chart EE XX PP LL OO SS II O O N N -- PP RR O O O F Only HEATREX offers a selection of explosion-proof heater constructions to meet your specific application. Features Hazardous Location NEC Classifications Ignition Temperature Code KW Range Standard Built-in Overtemperature Protection Other Standard Built-in Controls 233 Series Our most popular and versatile construction has a broad range of stock designs, special options and the industry’s lowest Ignition Temperature Code rating, 320°F (160°C). 233 Series Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups E, F, and G Class 1, Zones 1 and 2, Groups IIB T3C 320°F (160°C) Up to 30 KW Dual overtemperature protection with automatic and manual reset thermal cutouts Controlling contactor, control circuit transformer Standard Control Voltage 24V Single Point Line Voltage Connection for Incoming Power Yes Optional Built-in Controls Thermostat Yes Disconnect Switch Yes Selector Switch Yes Manual Reset Cutout Standard “Heater On” Pilot Light Yes “Warning” Pilot Light Yes Control Circuit Transformer Standard Standard Construction Heater Assembly Liquid-to-air heat exchanger, steel tube with aluminum fins, propylene glycol, immersion heater Cabinet/Housing Powder coated galvanized steel NEMA 7, 9 Control Enclosure Mounting Brackets Cast aluminum Wall, ceiling or pole mounting kits (optional) Optional Constructions Dirty Duty Corrosion Resistant 50 Hertz Motor Choice of 316SS Construction or Heresite® coating Yes Agency Approvals 6 FM (Factory Mutual) Yes CSA (Canadian Standards Association) Yes ABS (American Bureau of Shipping) No Comparison Chart 254 Series The industry’s smallest and most economical design for Class I, Group D applications up to 12 KW. Small, compact design with a wide range of optional built-in controls. 236 Series 254 Series Class I, Divisions 1 and 2, Group D Class 1, Zones 1 and 2, Group IIA Class I, Divisions 1 and 2, Groups B, C and D Class II, Divisions 1 and 2, Groups E, F, and G Class 1, Zones 1 and 2, Groups IIC T3 392°F (200°C) (Varies with KW) T3C 320°F (160°C) (Varies with classification) Up to 9.5 KW Primary automatic reset cutout Controlling contactor None 120V Maximum 277V Separate 120V motor line required Yes Yes Yes No No No No Yes No No No No No No Yes Stainless steel finned tubular elements Heater core enclosed in copper tube with large aluminum fins Stainless steel Powder coated galvanized steel Cast aluminum Cast aluminum Swivel mounting bracket (standard) Wall mounting bracket (standard) Yes Wet locations (NEMA 3) iridite coated elements No N/A Yes Yes Yes Yes Yes Yes H E A T E R S Up to 12 KW Primary and secondary automatic reset cutouts with fan relay E X P L O S I O N - P R O O F 236 Series 7 U N I T H E A T E R H E A T E R S 233 Series E X P L O S I O N - P R O O F HEATREX’s 233 Series explosion-proof unit heater is designed with both safety and versatility in mind. Unique features include: • Industry’s Lowest Ignition Temperature Code Rating: T3C, 320°F (160°C) • Dual Overtemperature Protection: With both automatic and manual reset overtemperature cutouts for additional safety. • Nontoxic Propylene Glycol Heat Transfer Fluid Applications •Aircraft Hangars/Service Areas •Paint Storage Areas •Chemical Storage/Handling Areas •Petrochemical Plants •Coal Preparation Plants •Compressor Stations •Sewage Pump Stations/ Treatment Plants •Grain Elevators •Spray Booths •Oil Refineries and Rigs Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups E, F and G Class I, Zones 1 and 2, Group IIB Temperature Code T3C, 320°F (160°C) • Low 70 PSIG Relief Valve Setting: This assures that in an emergency, the initial escaping vapor temperature remains below the 320°F (160°C) ignition temperature. • Corrosion Resistant Options: HEATREX offers three constructions suitable for most applications. Standard construction for use in dry non-corrosive areas includes: welded steel heat exchanger; powder-coated cabinet. A 316 stainless steel construction suitable for Waste Water Treatment Plants includes: 316 stainless steel heat exchanger, headers and tubes with aluminum fins; stainless steel cabinet; corrosion resistant hardware. Third construction is suitable for use in Chemical Plants where chlorides are present and includes: Heresite® coated heat exchanger, cabinet, fan blade; corrosion resistant hardware. Standard Construction Features 8 Heat Exchanger – Efficient liquid-to-air design utilizes an all welded steel headers and finned tube construction with spiral wound aluminum fins. Industrial grade HEATREX heating elements are immersed in a nontoxic, inhibited, propylene glycol heat transfer fluid that provides freeze protection down to -49°F (-45°C). The heat exchanger is hydrostatically tested at 350 psig. A pressure relief valve provides excess pressure protection and is set at 70 psig. is rated for Class I, Groups C and D, Class II, Groups F and G. The minimum operating temperature is -14°F (-25°C) and the minimum storage temperature is -49°F (-45°C). Optional motor ratings are described on page 9. Fan Motor Assembly – Consists of an explosion-proof motor fitted with an aluminum fan blade. The motor has double-shielded, permanently lubricated ball bearings and automatic reset line breaking thermal overload protection. Motors furnished on standard units operate at line voltage and are prewired to the control enclosure so separate field wiring to the motor is not required. The standard motor Controls – Factory mounted on the unit heater. Standard builtin controls include automatic and manual reset overtemperature cutouts, controlling magnetic contactor, and 24-volt control circuit transformer housed in a NEMA 7, 9 cast aluminum enclosure. Cabinet/Louvers – Industrial grade, corrosion resistant construction fabricated from powder coated 14-gauge galvanized steel. The adjustable louvers have minimum opening safety stops. U N I T H E A T E R 233 Series E X P L O S I O N - P R O O F Factory Built-in Options Code Option Description Availability Code (2) 316 Stainless steel heat exchanger with aluminum fins, 316 stainless steel cabinet; aluminum fan blade; cast aluminum NEMA 4X, 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor, which has passed the ASTM B117 salt-spray test. C C2 Dirty Duty Corrosion-Resistant Construction (Chemical Plants) Heresite® coated heat exchanger, cabinet and fan blade; cast aluminum NEMA 4X, 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor which has passed the ASTM B117 salt-spray test. C D Disconnect Switch Factory installed on the unit heater above the control enclosure. This is an inexpensive and positive way to meet NEC/CEC requirements for a disconnecting means within sight of the heater. AS E Group E (Metal Dust) Construction Class II, Group E (Metal Dust) Construction Temperature Code T3C, 320°F (160°C) C H 50 Hertz Motor Optional motors for international requirements. (See page 13 for KW availability) C K “Warning” Pilot Light Indicates when the thermal cutouts have tripped and the unit heater needs servicing. AS L “Heater On” Pilot Light Indicates when the electric heating elements are energized. AS M Manual Reset Thermal Cutout with Backup Contactor A pilot duty manual reset thermal cutout with a backup contactor is provided for independent secondary overtemperature protection. This option cannot be provided if option Code S or V are also specified. AS S Auto/Fan Selector Switch A two-position switch wired to the control circuit for auto (automatic heat) and fan only control. This selector switch cannot be provided if option Code M or V are also specified. AS T Adjustable Thermostat Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50° to 90°F (10° to 32°C) range. AS V 120 Volt Control Circuit Fused secondary and grounded Can be provided when required for special external thermostat circuit. This option cannot be provided if option Code S or M are also specified. Nor can both K and L be specified. AS H E A T E R S C1 316 Stainless Steel Corrosion-Resistant Construction (Waste Water Treatment Plants) (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. 9 H E A T E R S 233 Series U N I T H E A T E R Accessory Items Heater Mounting Kits 5" (127 mm) E X P L O S I O N - P R O O F These are available for ceiling, wall and pole mounting configurations as described below. Specify type required and catalog number at time of order entry. 6-1/8" (159.76 mm) MW MH 2.5 (63.5) 5" (127 mm) Ceiling Mounting Kit MW Wall Mounting Kit Size MH In. (mm) MW In. (mm) 1 11.063 (281) 9 (228.6) 2 15.063 (382.6) 7 (177.8) 3 19.063 (484.2) 5 (127) Pole Mounting Kit Unit Heater Mounting Kits (One kit required per heater) Standard Mounting Kits for use in most applications Catalog Number Description 1022451 Ceiling Mounting Kit, for Frame Size 1, 2, 3 1022454 Wall Mounting Kit, for Frame Size 1, 2, 3 1022457 Pole Mounting Kit, for Frame Size 1, 2, 3 Availability Code (2) AS Optional Mounting Kits for Option C1 or C2 heaters. Catalog Number Description 1022451-S Corrosion Resistant Ceiling Mounting Kit, for Frame Size 1, 2, 3 1022454-S Corrosion Resistant Wall Mounting Kit, for Frame Size 1, 2, 3 1022457-S Corrosion Resistant Pole Mounting Kit, for Frame Size 1, 2, 3 (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Remote Room Thermostat – Use catalog number 1007002. See page 98. 10 Availability Code (2) AS U N I T 233 Series H E A T E R Frame Size Size 1 Size 2 Size 3 ‘X’ In. (mm) 21.75 (552.45) 21.75 (552.45) 20.875 (530.23) ‘Y’ In. (mm) 19.375 (492.125) 23.375 (593.725) 27.375 (695.325) ‘Z’ In. (mm) 16.063 (408) 20.188 (512.775) 24.188 (614.375) Net Lbs. (kgs) 110 (49.89) 150 (68.03) 190 (86.18) Shipping Lbs (kgs) 130 (58.96) 169 (76.65) 216 (97.97) Overall Heater Dimensions Weight 60 Hertz Heaters KW Range 7.5 - 10 25 30 650 (1104) 850 (1444) 1800 (3058) 3110 (5283) 3850 (6541) Air Throw Feet (m) 15 (4.5) 25 (7.6) 45 (13.7) 65 (19.8) 75 (22.8) RPM Motor/Fan 15 20 1725 HP 1/4 Fan Blade Dia. In. (mm) 1/2 12 (304.8) 16 (406.4) 20 (508) 50 Hertz Heaters KW Range Airflow Characteristics 2.5 - 4.2 6.3 - 8.4 Air Volume CFM (cubic meter/hr.) 550 (934) 700 (1189) 1500 (2549) 2600 (4417) Air Throw Feet (m) 13 (4) 22 (7) 39 (12) 57 (17) 16 (406.4) 20 (508) RPM Motor/Fan 12.5 16.7 H E A T E R S Airflow Characteristics 3-5 Air Volume CFM (cubic meter/hr.) E X P L O S I O N - P R O O F Dimensions, Airflows and Weights 21 - 25 1438 HP 1/4 Fan Blade Dia. In. (mm) 12 (304.8) 1/2 Y X Side View 6-3/4” Z Front View 11 H E A T E R S 233 Series U N I T Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups F and G Class I, Zones 1 and 2, Group IIB Temperature Code T3C, 320°F (160°C) E X P L O S I O N - P R O O F Heater Listing 60 Hz KW 3 5 7.5 10 15 20 25 30 H E A T E R Volts Phase Total Amps (1) Frame Size Approximate Air Temperature Rise °F (°C) Catalog Number 208 1 17 1 15 (8) HX-233-FA-0036C 240 1 15 1 15 (8) HX-233-FA-0036J 208 3 10 1 15 (8) HX-233-FA-0036D 240 3 9 1 15 (8) HX-233-FA-0036K 480 3 5 1 15 (8) HX-233-FA-0036U 600 3 4 1 15 (8) HX-233-FA-0036Z 208 1 26 1 25 (13) HX-233-FA-0056C 240 1 23 1 25 (13) HX-233-FA-0056J 208 3 16 1 25 (13) HX-233-FA-0056D 240 3 14 1 25 (13) HX-233-FA-0056K 480 3 7 1 25 (13) HX-233-FA-0056U 600 3 6 1 25 (13) HX-233-FA-0056Z 208 1 38 1 28 (16) HX-233-FA-0086C 240 1 34 1 28 (16) HX-233-FA-0086J 208 3 23 1 28 (16) HX-233-FA-0086D 240 3 20 1 28 (16) HX-233-FA-0086K 480 3 10 1 28 (16) HX-233-FA-0086U 600 3 9 1 28 (16) HX-233-FA-0086Z 240 1 44 1 38 (21) HX-233-FA-0106J 208 3 30 1 38 (21) HX-233-FA-0106D 240 3 26 1 38 (21) HX-233-FA-0106K 480 3 13 1 38 (21) HX-233-FA-0106U 600 3 11 1 38 (21) HX-233-FA-0106Z 208 3 44 2 27 (15) HX-233-FB-0156D 240 3 38 2 27 (15) HX-233-FB-0156K 480 3 19 2 27 (15) HX-233-FB-0156U 600 3 16 2 27 (15) HX-233-FB-0156Z 480 3 25 2 35 (19) HX-233-FB-0206U 600 3 21 2 35 (19) HX-233-FB-0206Z 480 3 31 3 26 (14) HX-233-FC-0256U 600 3 25 3 26 (14) HX-233-FC-0256Z 480 3 37 3 25 (13) HX-233-FC-0306U 600 3 30 3 25 (13) HX-233-FC-0306Z (1) Total Amps = Heating element amps and motor amps. (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. 12 Availability (2) AS U N I T 233 Series H E A T E R Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups F and G Class I, Zones 1 and 2, Group IIB Temperature Code T3C, 320°F (160°C) Heater Listing 50 Hz KW 2.5 6.3 8.4 12.5 16.7 21 25 Volts Phase Total Amps (1) Frame Size Approximate Air Temperature Rise °F (°C) Catalog Number 220 1 14 1 14 (8) HX-233-FA-0036E 220 3 9 1 14 (8) HX-233-FA-0036F 380 3 6 1 14 (8) HX-233-FA-0036G 400 3 6 1 14 (8) HX-233-FA-0036H 414 3 5 1 14 (8) HX-233-FA-0036I 220 1 21 1 24 (13) HX-233-FA-0056E 220 3 13 1 24 (13) HX-233-FA-0056F 380 3 9 1 24 (13) HX-233-FA-0056G 400 3 8 1 24 (13) HX-233-FA-0056H 415 3 7 1 24 (13) HX-233-FA-0056I 220 1 31 1 28 (16) HX-233-FA-0076E 220 3 19 1 28 (16) HX-233-FA-0076F 380 3 12 1 28 (16) HX-233-FA-0076G 400 3 11 1 28 (16) HX-233-FA-0076H 415 3 10 1 28 (16) HX-233-FA-0076I 220 1 40 1 38 (21) HX-233-FA-0096E 220 3 24 1 38 (21) HX-233-FA-0096F 380 3 15 1 38 (21) HX-233-FA-0096G 400 3 13 1 38 (21) HX-233-FA-0096H 415 3 13 1 38 (21) HX-233-FA-0096I 220 3 35 2 26 (14) HX-233-FB-0136F 380 3 21 2 26 (14) HX-233-FB-0136G 400 3 19 2 26 (14) HX-233-FB-0136H 415 3 18 2 26 (14) HX-233-FB-0136I 220 3 46 2 35 (19) HX-233-FB-0176F 380 3 28 2 35 (19) HX-233-FB-0176G 400 3 25 2 35 (19) HX-233-FB-0176H 415 3 24 2 35 (19) HX-233-FB-0176I 380 3 33 3 26 (14) HX-233-FC-0216G 400 3 32 3 26 (14) HX-233-FC-0216H 415 3 31 3 26 (14) HX-233-FC-0216I 380 3 39 3 30 (17) HX-233-FC-0256G 400 3 37 3 30 (17) HX-233-FC-0256H 415 3 36 3 30 (17) HX-233-FC-0256I Availability (2) H E A T E R S 4.2 E X P L O S I O N - P R O O F Explosion-Proof Unit Heater C (1) Total Amps = Heating element amps and motor amps. (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. 13 233 Series U N I T H E A T E R H E A T E R S Explosion-Proof Unit Heater E X P L O S I O N - P R O O F Three Constructions to Choose From; Standard, Stainless Steel or Heresite® Standard - Non-corrosive applications Optional 316 Stainless Steel or Heresite® Coating • Aircraft Hangars/Servicing Areas • Coal Mines/Preparation Plants • Gasoline Fueling/Storage Areas • Paint Spraying/Storage Areas • Utility Plants • Chemical Plants • Chemical Storage/Handling Areas • Food Processing Plants • Oil Refineries • Petrochemical Plants • Sewage Treatment/Wastewater Treatment Plants Heavy 14-Gauge Cabinet • Powder coated - standard 16 stainless steel or Heresite® coat •3 ed - options Standard • 24VAC transformer • Contactor • Automatic and manual reset overtemperature thermal cutouts Adjustable louvers Finger safe fan guard split construction for easy removal for field servicing. Optional • Disconnect switch with lockout • Fan selector switch • Thermostat Thermally-protected explosion-proof motor with heavy-gauge aluminum fan blade designed for easy field servicing. Designed for Easy Servicing Heater Core All welded construction with: • Painted steel headers with steel tubes and spiral wound aluminum fins - standard • 316 stainless steel or heresite® construction - options • Removable core • Split fan guard • Easy access to motor and fan • Replaceable automatic and manual thermal cutouts • Threaded control enclosure Heresite® is a registered trademark of Heresite® Protective Coatings, Inc. 14 Core can be easily removed through bottom of cabinet U N I T H E A T E R ® Class I, Divisions 1 and 2, Group D Class I, Zones 1 and 2, Group IIA American Bureau of Shipping HEATREX’s 236 Series explosion-proof unit heater is designed with both size and economy in mind. Advantages and unique features include: • Compact Size: This small design is only 13 inches wide, which makes it ideal for applications where limited space is available. Applications •Chemical Storage/Handling Areas •Oil Platforms and Refineries •Compressor Stations •Sewage/Wastewater Treatment Plants • Marine and Offshore •Spray Booths • Redundant Overtemperature Protection: Primary and secondary automatic reset thermal cutouts for additional safety. • Stainless Steel Construction: Provides superior corrosion resistant protection. Optional Dirty Duty construction adds polyester powder coating to all aluminum parts for use in corrosive applications. H E A T E R S • Low Cost: The design offers the most economical solution for heating small Class I, Group D hazardous areas. It is a cost effective alternative to the use of explosionproof convection heaters. E X P L O S I O N - P R O O F 236 Series • Optional Marine Duty Construction: Ideal for shipboard use where size, weight and corrosion resistant construction are critical. Standard Construction Features Heating Elements – Industrial grade, Type 304 stainless steel finned tubular heating elements are manufactured by HEATREX. Terminal Enclosure – A NEMA 7, 9 cast aluminum enclosure with a threaded bottom cover permits easy access to the built-in controls from underneath the heater. Housing – Round, 16-gauge stainless steel shroud. Grilles – An adjustable stainless steel louvered outlet grille directs airflow 45° up or down and a heavy gauge stainless steel rear grille protects against accidental contact with the fan blade. Stainless Steel Swivel Mounting Bracket – Supplied as standard with all 236 Series explosion-proof unit heaters. This multi-purpose bracket can be used for either wall or ceiling mounting. Built-In Controls – Include primary and secondary automatic reset overtemperature cutouts, controlling contactor, and a time delay relay which keeps the fan running to cool the heating elements after they have been deenergized. Fan Motor Assembly – Consists of a 120-volt, 1-phase 60 hertz motor fitted with an aluminum fan blade. The totally enclosed motor is UL Listed for Class I, Group D applications and includes permanently lubricated ball bearings and built-in thermal overload protection. The motor is factory wired into the enclosure to reduce field wiring, but requires a separate 120-volt power supply. 15 H E A T E R S 236 Series U N I T H E A T E R Custom Options Code Option Dirty Duty Corrosion Resistant Construction Includes polyester powder coated fan blade, wiring conduit and fittings, NEMA 4X, 7, 9 enclosure. C CM Marine Duty Construction Dirty Duty Construction with manual reset thermal cutout. Meets U.S. Coast Guard requirements per 46CFR111.87 and is ABS Approved C M Manual Reset Cutout Can be specified to replace secondary automatic cutout. C T Adjustable Thermostat Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50° to 90°F (10° to 32°C) range. C C E X P L O S I O N - P R O O F Availability Code (2) Description (2) AS = Assembly Stock, C = Custom Assembly Stock heaters ordered with custom options are subject to longer delivery. Dimensions, Airflows and Weights KW 3 5 7 10 12 Ignition Temperature Code T3 T2C T2 T1 T1 9 (5) 15 (8) 22 (12) 31 (17) 37 (21) Air Volume CFM (cubic meters/hr) 1050 (1784) 1050 (1784) 1050 (1784) 1050 (1784) 1050 (1784) Air Throw Feet (m) 25 (8) 25 (8) 25 (8) 25 (8) 25 (8) Outlet Velocity FPM (meters/min) 1140 (348) 1140 (348) 1140 (348) 1140 (348) 1140 (348) RPM 1725 1725 1725 1725 1725 HP 1/6 1/6 1/6 1/6 1/6 Approximate Air Temperature Rise °F (°C) Airflow Characteristics Motor/Fan Fan Blade Dia. Inch ( cm) 12 (31) Net Lbs (kgs) 96 (44) Shipping Lbs (kgs) 110 (50) Weight CEILING CEILING 8” Min (20.3 cm) 120V Motor: Control Wiring When Optional Built-On Thermostat is Used 5 ¾” (14.6 cm) 15 16” (3.3 cm) Min Swivel Bracket (Ceiling Mounted) WALL Optional Built-On Thermostat 9 ¼” (48.9 cm) AIRFLOW 20” (50.8 cm) 8” Min (20.3 cm) 4⅜” (11.1 cm) Min 120V Motor: Control Wiring When Optional Built-OnThermostat is Used Heater Wiring 22” (55.9 cm) 28 ¼” (71.8 cm) Max 18” Ref. (45.7 cm) Standard Wall and Ceiling Installation with Swivel Mounting Bracket Remote Room Thermostat – Use catalog number 1007002. See page 98. 16 13” (33 cm) U N I T T2 572 (300) T1 842 (450) T1 842 (450) 5 7 10 12 Volts Phase Heater Amps (1) Catalog Number 208 1 14.5 HX-236-F01T-0037C-7000 C 240 1 12.5 HX-236-F01T-0037J-7001 C 480 1 6.3 HX-236-F01T-0037T-7002 C 208 3 8.4 HX-236-F01T-0037D-7003 C 240 3 7.3 HX-236-F01T-0037K-7004 C 480 3 3.7 HX-236-F01T-0037U-7005 C 600 3 2.9 HX-236-F01T-0037Z-7006 C 208 1 24.1 HX-236-F01T-0055C-7007 C 240 1 20.9 HX-236-F01T-0055J-7008 C 480 1 10.5 HX-236-F01T-0055T-7009 C 208 3 13.9 HX-236-F01T-0055D-7010 C 240 3 12.1 HX-236-F01T-0055K-7011 C 480 3 8.1 HX-236-F01T-0055U-7012 C 600 3 4.9 HX-236-F01T-0055Z-7013 C 208 1 33.7 HX-236-F01T-0072C-7021 C 240 1 29.2 HX-236-F01T-0072J-7022 C 480 1 14.6 HX-236-F01T-0072T-7023 C 208 3 19.5 HX-236-F01T-0072D-7024 C 240 3 16.9 HX-236-F01T-0072K-7025 C 480 3 8.5 HX-236-F01T-0072U-7026 C 600 3 6.8 HX-236-F01T-0072Z-7027 C 240 1 41.7 HX-236-F01T-0101J-7035 C 480 1 20.9 HX-236-F01T-0101T-7036 C 208 3 27.8 HX-236-F01T-0101D-7037 C 240 3 24.1 HX-236-F01T-0101K-7038 C 480 3 12.1 HX-236-F01T-0101U-7039 C 600 3 9.7 HX-236-F01T-0101Z-7040 C 480 1 25.0 HX-236-F01T-0121T-7041 C 240 3 29.0 HX-236-F01T-0121K-7042 C 480 3 14.5 HX-236-F01T-0121U-7043 C 600 3 11.6 HX-236-F01T-0121Z-7044 C Availability Code (2) ® American Bureau of Shipping H E A T E R S T2C 446 (230) 3 E X P L O S I O N - P R O O F T3 392 (200) KW 236 Series Class I, Divisions 1 and 2, Group D Class I, Zones 1 and 2, Group IIA Heater Listing Ignition Temperature Code °F (°C) H E A T E R (1) The amps shown are for the heating elements only. The 120V, 1 Ph 60 Hz motor draws 3.8 amps and requires a separate 120V power supply. (2) Availability Code: C = Custom 17 H E A T E R S 254 Series ® E X P L O S I O N - P R O O F American Bureau of Shipping Class I, Divisions 1 and 2, Groups B, C and D Class II, Divisions 1 and 2, Groups E, F and G Class I, Zones 1 and 2, Group IIC Applications •Battery Storage Areas •Chemical Plants •Coal Handling Facilities •Dry Cleaning Plants •Gasoline Fueling/Storage Areas • Grain Elevators • Oil Refineries • Paint Spraying/Storage Areas • Petrochemical Plants HEATREX’s explosion-proof convector is designed to provide a heavy duty and corrosion resistant heat source. Features include: • Wide Selection of Sizes: Four compact sizes to fit any space with ratings from 500 to 9,500 watts. • Sloped Top Cabinet: Prevents objects from being set on top of the convector, which can restrict airflow and cause overheating. • Single and Three-Phase: Unique design provides single and balanced three-phase loads in a single element. • Gas and Dust Atmospheres: Three listings cover the entire field, two for hazardous gases and vapors and one for dust particles. • Wet Locations: All unit sizes available with iriditecoated elements and powder-coated frames for NEMA 3 wet locations. Standard Construction Features Element – Grade A Nickel-Chromium heating coils are insulated with ceramics and magnesium oxide from the copper heater tube and fitted with large aluminum fins locked in place. Cabinet – Heavy gauge galvanized steel cabinet is painted with a beige powder coat for durability. Cabinet should be mounted at least 6 inches (152 mm) above the floor. Factory-furnished wall brackets make installation easy. 18 Thermal Protection – A linear limit, automatic reset thermal cutout is built into every unit. Complete Electrical Package – For larger single-phase and all three-phase units, a built-on contactor and transformer option package are available. 254 Series All single-phase heaters rated over 22 amps or 277 volts and all three-phase heaters require a magnetic contactor. Some electrical combinations will also require a control transformer. To simplify field installation, these Code accessories are factory-mounted on the heater cabinet and factory pre-wired (not available on Size 1 convectors). Option Description Availability Code (2) Electric Control Option (1) (without thermostat) Classes I and II, Groups B, C, E, D, F and G includes contactor and transformer (as required). Required for all three-phase and single-phase heaters over 22 amps or 277 volts AS B2/S1 Thermostat & Controls (1) Classes I and II, Groups C, D, E, F and G includes thermostat, contactor and transformer (as required). AS B3 Thermostat & Controls (Group B) (1) Classes I and II, Groups B, C, D, E, F and G includes thermostat, contactor and transformer (as required). Thermostat has internal set point. AS S1 Thermostat Only (1) Classes I and II, Groups C, D, E, F and G single-phase heaters rated up to 22 amps at 120-277 volts. Use remote room thermostat Catalog Number 1007002 for Size 1 convectors. AS S2 Thermostat Only (Group B) (1) Classes I and II, Groups B, C, D, E, F and G single-phase heaters rated up to 22 amps at 120-277 volts. Thermostat has internal set point. Use remote room thermostat Catalog Number 1007022 for Size 1 convectors. AS Description Availability Code (2) H E A T E R S B2 E X P L O S I O N - P R O O F Electrical Package Options (1) These options are not available on Size 1 Convectors. Custom Option Code C1 Option NEMA 3 rated heater construction not available with S1, B2/S1 and S2 thermostat options. Wet Locations C (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Dimensions and Weights Unit Size Dimensions - In. (cm) Weight - Lb (kg) Length (L) Height (H) Depth (D) Without Controls 1 26 (66) 6 (15) 4 ½ (11) 13 (5.9) 2 26 (66) 16 (41) 8 (20) 27 (12.2) 3 39 (99) 16 (41) 8 (20) 36 (16.3) 4 67 ½ (171) 16 (41) 8 (20) 60 (27.2) Remote Room Thermostat - See page 98. Thermostat (Ifpec S ifie Control Package Option: B2/S1 19 E X P L O S I O N - P R O O F H E A T E R S 254 Series ® Heater Listing Class I, Divisions 1 and 2, Groups B, C and D Class I, Zones 1 and 2, Group IIC Ignition Temperature Code °F (°C) KW 0.5 1 1.8 2.5 T2A 536 (280) 3.6 4.4 6.5 7.5 9.5 Magnetic contactor required. 20 American Bureau of Shipping Volts/ Phase Heater Amps Unit Size Catalog Number 120/1 4.2 1 HX-254-F0310052B 208/1 2.4 1 HX-254-F0310052C 240/1 2.1 1 HX-254-F0310052J 120/1 8.3 1 HX-254-F0310102B 208/1 4.8 1 HX-254-F0310102C 240/1 4.2 1 HX-254-F0310102J 120/1 15.0 2 HX-254-F0320182B 208/1 8.7 2 HX-254-F0320182C 240/1 7.5 2 HX-254-F0320182J 480/3▲ 1.3 2 HX-254-F0320182U 600/3▲ 1.8 2 HX-254-F0320182Z 208/1 12.0 2 HX-254-F0320252C 240/1 10.4 2 HX-254-F0320252J 208/3 6.9 2 HX-254-F0320252D 480/3▲ 3.0 2 HX-254-F0320252U 600/3▲ 2.4 2 HX-254-F0320252Z 208/1 17.3 3 HX-254-F0330362C 240/1 15.0 3 HX-254-F0330362J 208/3 10.0 3 HX-254-F0330362D 480/3▲ 4.3 3 HX-254-F0330362U 600/3▲ 3.5 3 HX-254-F0330362Z 240/1 18.3 3 HX-254-F0330442J 208/3 12.2 3 HX-254-F0330442D 480/3 5.3 3 HX-254-F0330442U 600/3▲ 4.3 3 HX-254-F0330442Z 240/1 27.1 4 HX-254-F0340652J 208/3 18.0 4 HX-254-F0340652D 480/3▲ 7.8 4 HX-254-F0340652U 600/3▲ 6.3 4 HX-254-F30340652Z 240/1 31.3 4 HX-254-F0340752J 208/3 20.8 4 HX-254-F0340752D 480/3▲ 9.0 4 HX-254-F0340752U 600/3▲ 7.2 4 HX-254-F0340752Z 240/1 39.6 4 HX-254-F0340852J 208/3 26.4 4 HX-254-F0340962D 480/3▲ 11.4 4 HX-254-F0340952U 600/3▲ 9.1 4 Availability Code (2) AS HX-254-F0340952Z ▲Magnetic contactor and control transformer required. These accessories may be field mounted. For factory mounting, see Electrical Package Options on page 19. (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Other voltages available. Consult factory. 254 Series ® Class I, Divisions 1 and 2, Groups B, C and D Ignition Temperature Code °F (°C) KW 0.5 1.4 2.3 3.2 5 Volts/ Phase Heater Amps Unit Size Catalog Number 120/1 4.2 1 HX-254-F0610052B 208/1 240/1 120/1 208/1 240/1 120/1 208/1 240/1 208/3 480/3▲ 2.4 2.1 11.7 6.7 5.8 19.2 11.1 9.6 6.4 2.8 1 1 2 2 2 3 3 3 3 3 HX-254-F0610052C HX-254-F0610052J HX-254-F0620142B HX-254-F0620142C HX-254-F0620142J HX-254-F0630232B HX-254-F0630232C HX-254-F0630232J HX-254-F0630232D HX-254-F0630232U 600/3▲ 2.2 3 HX-254-F0630232Z 208/1 240/1 208/3 480/3▲ 15.4 13.3 8.9 3.8 4 4 4 4 HX-254-F0640322C HX-254-F0640322J HX-254-F0640322D HX-254-F0640322U 600/3▲ 3.1 4 HX-254-F0640322Z 240/1 208/3 480/3▲ 20.8 13.9 6.0 4 4 4 HX-254-F0640502J HX-254-F0640502D HX-254-F0640502U 600/3▲ 4.8 4 HX-254-F0640502Z Availability Code (2) AS H E A T E R S T3A 356 (180) American Bureau of Shipping E X P L O S I O N - P R O O F Heater Listing Class I, Divisions 1 and 2, Groups B, C and D Class II, Divisions 1 and 2, Groups E, F and G Ignition Temperature Code °F (°C) KW 0.5 1 T3C 320 (160) 1.7 3.2 Volts/ Phase Heater Amps Unit Size Catalog Number 120/1 208/1 240/1 120/1 208/1 240/1 120/1 208/1 240/1 480/3▲ 4.2 2.4 2.1 8.3 4.8 4.2 14.2 8.2 7.1 2.0 1 1 1 2 2 2 3 3 3 3 HX-254-F0810054B HX-254-F0810054C HX-254-F0810054J HX-254-F0820104B HX-254-F0820104C HX-254-F0820104J HX-254-F0830174B HX-254-F0830174C HX-254-F0830174J HX-254-F0830174U 600▲ 1.6 3 HX-254-F0830174Z 208/1 240/1 208/3 480/3▲ 15.4 13.3 8.9 3.8 4 4 4 4 HX-254-F0840324C HX-254-F0840324J HX-254-F0840324D HX-254-F0840324U 600/3▲ 3.1 4 HX-254-F0840324U Magnetic contactor required. ▲Magnetic contactor and control transformer required. These accessories may be field mounted. For factory mounting, see Electrical Package Options on page 19. Availability Code (2) AS (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Other voltages available. Consult factory. 21 Comparison Chart H E A T E R S Unit Heaters 928 926 F A N - F O R C E D 240 924 234 238 Features Typical Applications Food processing plants Marine duty Wastewater treatment plants 238 Series 240 Series 926 Series 924 Series Factories Factories Mechanical rooms Mechanical rooms Mechanical rooms Warehouses Storage rooms Workshops Workshops Warehouses Vertical 928 Series Gyms High bay areas Warehouses KW Range 2 to 47 3 to 38.4 3.3 to 50 2 to 60 3 to 5 5 to 30 Voltages up to 600/3 Up to 480/3 Up to 480/3 Up to 480/3 240/208/1 Up to 480/3 Airflow CFM Up to 2400 Up to 1774 Up to 3100 Up to 2000 300 Up to 2300 Discharge Horizontal Horizontal Horizontal or Vertical Horizontal or Vertical Horizontal Vertical Element Type Stainless steel finned tubular Stainless steel finned tubular Stainless steel finned tubular Stainless steel tubular or steel finned tubular Stainless steel tubular Steel finned tubular Standard Construction 22 Washdown 234 Series 16 gauge stain16 gauge galvaless steel shroud nized steel shroud and non-metallic and control NEMA 4X control enclosure enclosure 20-14 gauge (depending on 8 & 20 gauge steel 20 gauge galva18 gauge galvasize) galvanized cabinet nized steel cabinet nized steel cabinet steel cabinet Finish Stainless steel Beige polyester powder paint Camel polyester powder paint Almond polyester powder paint Almond polyester powder paint Almond polyester powder paint Mounting Ceiling or wall Ceiling or wall Ceiling or wall Ceiling or wall Ceiling or wall Ceiling Agency Approvals cULus & ABS cULus cULus CSAus CSAus CSAus 234 Series The HEATREX 234 Series unit heater is the perfect solution to the problem of heating people or equipment in non-hazardous environments where moisture and corrosion exist. Advantages include: Applications •Marine and Offshore •Car Washes •Power Generating Stations •Cement Plants •Steel Mills and Foundries •Coal Handling Areas •Swimming Pool Areas •Dairies •Wastewater Treatment Plants •Food Processing Plants H E A T E R S American Bureau of Shipping F A N - F O R C E D Washdown/Corrosion Resistant Unit Heater • Built-in Controls: All necessary safety and temperature controls are included in a single package. Components and motor are factory-wired to a single terminal block for field wiring, eliminating the chance for field error and reducing installation costs. • Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit. • Corrosion Resistant: Stainless steel construction, powdercoated aluminum fan blade and nonmetallic NEMA 4X terminal enclosure resist corrosion found in sewage treatment plants, swimming pool areas, car washes, paper mills and marine installations. • Washable: This watertight construction can be hosed down without disconnecting the heater, which makes it ideal for coal handling areas, steel mills, foundries, ships, wood finishing plants, cement, sand, grain and food processing facilities. Standard Construction Features Heating Elements – Industrial grade, Type 316 stainless steel tubular elements with stainless steel fins, manufactured by HEATREX. Control Enclosure – The non-metallic enclosure, which houses the element terminals and built-in controls, will not rust and meets NEMA 4X hose-down requirements. Fan Motor Assembly – Totally enclosed, epoxy coated, UL Recognized motor with permanently lubricated ball bearings for longer life. Designed to resist moisture and corrosion. Factory-wired to NEMA 4X enclosure. Fitted with a powdercoated, aluminum fan blade suitable for corrosive salt spray environments. Built-in Controls – Include automatic reset overtemperature cutout, fan delay relay, controlling contactor, transformer for 24-volt control circuit, terminal block for field wiring and a separate motor contactor (when required). Housing – Heating elements and motor are enclosed in a round, heavy 16-gauge stainless steel shroud. Inlet/Outlet Grilles – Adjustable, stainless steel, louvered outlet grille can be rotated 90° to direct airflow up, down, left or right. Heavy gauge, stainless steel rear grille protects against accidental contact with the fan blade. Mounting Bracket – The heater comes complete with a stainless steel swivel mounting bracket which can be used either for wall or ceiling mounting. Four field-supplied 3/8-16 threaded rods can also be used for ceiling installation. 23 F A N - F O R C E D H E A T E R S 234 Series Washdown/Corrosion Resistant Unit Heater Factory Built-in Options Code Availability Code (2) Description B Delete swivel mounting bracket. Heater installs from the ceiling with field furnished threaded rods. AS C Epoxy painted stainless steel parts, housing, grilles and fan blade C D Power disconnect switch AS E Monel finned tubular elements C L “Heater on” pilot light AS M Secondary manual reset overtemperature cutout. Required for U.S. Coast Guard and ABS Approved designs. AS S Three-position selector switch (heater-standby-fan) AS 1- Stage Built-in thermostat 40 to 100° F (5 to 38° C) range AS 2- Stage Built-in thermostat 40 to 120° F (5 to 49° C) range (Option “X” required) C V 120 volt control circuit, fused secondary and grounded AS X 2-Stage Control C T (2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery. Remote Room Thermostat – See page 98. KW Dimensions, Airflows and Weights Overall Heater Dimensions Mounting Hole Dimensions Airflow Characteristics Weight 2 - 7.5 7.6 - 12 12.1 - 47 “X” Inch (cm) 15½ (39) 15½ (39) 26 (66) “Y” Inch (cm) 21½ (55) 21½ (55) 28 (71) “Z” Inch (cm) 13 (33) 13 (33) 20 (51) “BH” Inch (cm) 4¼ (11) 4¼ (11) 7⅛ (18) “BL” Inch (cm) 19½ (50) 19½ (50) 22¼ (57) “M” Inch (cm) 8½ (22) 8½ (22) 3¼ (8) Air Volume CFM (cubic meters/hr) 700 (1189) 1450 (2463) 2400 (4077) Air Throw Feet (m) 26 (8) 43 (13) 50 (15) Outlet Velocity FPM (meters/min) 760 (232) 1575 (481) 1200 (366) Net Lbs (kgs) 56 (25) 56 (25) 115 (52) Shipping Lbs (kgs) 70 (32) 70 (32) 130 (60) Ceiling Swivel Bracket (Wall Mounting) 8” Min Ceiling Z Four 3/8 - 16 threaded rods (not supplied with the heater) Swivel Bracket (Ceiling Mounting) BL BH Wall 8” Min. 8” Min. 8” Min. Y 24 Standard Wall and Ceiling Installation with Swivel Mounting Bracket Wall X Conduit Opening For Field Wiring 6 Foot Min (Any Mounting) Floor Wall M Optional Ceiling Installation with Four Threaded Rods 234 Series Heater Listing KW 2 5 7.5 9 10 12 12.5 15 20 25 30 35 38.4 47 Volts Ph Total Amps (1) Approximate Air Temperature Rise °F (°C) HP Volts Ph 120 208 240 277 120 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 240 277 480 208 240 480 600 277 480 208 240 480 600 208 240 480 600 208 240 480 600 480 600 480 600 480 600 480 600 480 600 600 1 1 1 1 1 1 1 1 1 3 3 3 3 1 1 1 1 3 3 3 3 1 1 1 1 3 3 3 3 1 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 21 12 11 10 29 17 15 13 8 11 10 5 4 27 23 20 12 16 15 8 6 39 34 29 17 23 21 11 9 46 40 35 20 28 24 12 10 44 39 22 30 27 14 11 46 27 36 32 16 13 37 33 17 14 44 39 20 16 26 21 32 26 38 31 44 35 48 38 47 9 (5) 9 (5) 9 (5) 9 (5) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 24 (13) 24 (13) 24 (13) 24 (13) 24 (13) 24 (13) 24 (13) 24 (13) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 20 (11) 20 (11) 20 (11) 20 (11) 20 (11) 20 (11) 20 (11) 20 (11) 22 (12) 22 (12) 22 (12) 22 (12) 22 (12) 22 (12) 22 (12) 26 (14) 26 (14) 26 (14) 26 (14) 26 (14) 26 (14) 17 (9) 17 (9) 17 (9) 17 (9) 21 (12) 21 (12) 21 (12) 21 (12) 28 (16) 28 (16) 35 (19) 35 (19) 42 (23) 42 (23) 48 (27) 48 (27) 54 (30) 54 (30) 64 (36) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 120 208 240 277 120 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 208 240 277 480 208 240 480 600 240 277 480 208 240 480 600 277 480 208 240 480 600 208 240 480 600 208 240 480 600 480 600 480 600 480 600 480 600 480 600 600 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Motor Catalog Number 2-Stage Control HX-234-U11R-0020B HX-234-U11R-0020C HX-234-U11R-0020J HX-234-U11R-0020N HX-234-U11N-0030B HX-234-U11N-0030C HX-234-U11N-0030J HX-234-U11N-0030N HX-234-U11N-0030T HX-234-U11N-0030D HX-234-U11N-0030K HX-234-U11N-0030U HX-234-U11N-0030Z HX-234-U11R-0050C HX-234-U11R-0050J HX-234-U11R-0050N HX-234-U11R-0050T HX-234-U11N-0050D HX-234-U11N-0050K HX-234-U11N-0050U HX-234-U11N-0050Z HX-234-U11N-0080C HX-234-U11N-0080J HX-234-U11N-0080N HX-234-U11N-0080T HX-234-U11N-0080D HX-234-U11N-0080K HX-234-U11N-0080U HX-234-U11N-0080Z HX-234-U11N-0090C HX-234-U11N-0090J HX-234-U11N-0090N HX-234-U11N-0090T HX-234-U11N-0090D HX-234-U11N-0090K HX-234-U11N-0090U HX-234-U11N-0090Z HX-234-U11N-0100J HX-234-U11N-0100N HX-234-U11N-0100T HX-234-U11N-0100D HX-234-U11N-0100K HX-234-U11N-0100U HX-234-U11N-0100Z HX-234-U11N-0120N HX-234-U11N-0120T HX-234-U11N-0120D HX-234-U11N-0120K HX-234-U11N-0120U HX-234-U11N-0120Z HX-234-U11L-0130D HX-234-U11L-0130K HX-234-U11L-0130U HX-234-U11L-0130Z HX-234-U11L-0150D HX-234-U11L-0150K HX-234-U11L-0150U HX-234-U11L-0150Z HX-234-U11L-0200U HX-234-U11L-0200Z HX-234-U11A-0250U HX-234-U11A-0250Z HX-234-U11A-0300U HX-234-U11A-0300Z HX-234-U11A-0350U HX-234-U11A-0350Z HX-234-U11A-0390U HX-234-U11A-0390Z HX-234-U11A-0470Z 1B 1B 1B 1B 1B 1B 1B 1B 1B 1A 1A 1A 1A 1B 1B 1B 1B 1A 1A 1A 1A 1B 1B 1B 1B 1A 1A 1A 1A 1B 1B 1B 1B 1A 1A 1A 1A 1B 1B 1B 1A 1A 1A 1A 1A 1B 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1B 1B 1B 1B 1B 1B 1B 1B 1B Availability Code (2)(3) American Bureau of Shipping H E A T E R S 3 For Non-Hazardous Areas F A N - F O R C E D Washdown/Corrosion Resistant Unit Heater AS (1) Total Amps = Heating element amps and motor amps. (2) Availability Code: AS = Assembly Stock, (3) Stock heaters ordered with custom options subject to longer delivery. NOTE: 2-Stage heaters can be field wired as single stage. 1A = Optional 2-stage control, unbalanced (option ‘X’). 1B = Optional 2-stage control, balanced (option ‘X’) 25 Industrial Unit Heater F A N - F O R C E D H E A T E R S 238 Series HEATREX’s industrial unit heater is designed for maximum heating performance in non-hazardous and noncorrosive environments. Features include: • Unique Design: Round design of the industrial unit heater provides uniform airflow over the elements to prevent hot spots and ensure even discharge temperatures. Circular stainless steel finned tubular elements have a longer life due to lower operating temperatures. • Built-in Controls: Heaters are completely assembled with all electrical components built-in at the factory to reduce installation costs. Applications •Aircraft Hangars •Power Generating Stations •Entryways •Pump Houses •Factories •Service Stations •Garages • Improved Performance: High CFM’s and air throw up to 50 feet promote air circulation within the space. More uniform temperature increases comfort levels and helps to eliminate cold spots. • Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit. Standard Construction Features Heating Elements – Industrial grade, Type 304 stainless steel finned tubular elements, manufactured by HEATREX. Housing – Heating elements and motor are enclosed in a round, 16-gauge galvanized steel enclosure which has a powder coat finish for durability. Inlet/Outlet Grilles – Inlet grille complies with OSHA requirements for fan blade guard. Outlet grille has 45° angled louvers to direct airflow. Fan Motor – Motor is UL Recognized with built-in 26 thermal protection. Built-in Controls – Include main control magnetic contactor, control voltage transformer, automatic reset thermal cutout and fan thermostat. Mounting Bracket – Wall mounting bracket with single point suspension allows the heater to rotate a full 360°. 238 Series Factory Built-in Options Code No mounting bracket Substitute wall mounting bracket with ceiling bracket Power Disconnect Switch Adjustable Outlet Louvers Premium Fan Motor “Heater On” Pilot Light Manual Reset Thermal Cutout Built-in Fan Relay - Required for Remote Fan Switch Three-position Selector Switch (Heater-Standby-Fan) Built-in Thermostat 40° to 120° F (4° to 49° C) Range No Transformer - Customer supplied control voltage AS AS AS C AS AS AS AS AS AS AS (2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery. H E A T E R S B C D G H L M R S T X Availability Code (2) Description F A N - F O R C E D Industrial Unit Heater Dimensions, Weights and Air Throws Dimensions - In. (cm) M W X Y Z Weight Lb (kgs) 1 - 12 8¼ (21) 8¾ (22) 15 (38) 17 (43) 13 (41) 45 (20) 15 (5) 12.5 - 20 7 (18) 5½ (14) 16¼ (41) 23½ (60) 19¼ (49) 60 (27) 50 (15) 25 - 38.4 4 (10) 5½ (14) 20¾ (53) 23½ (60) 19¼ (49) 80 (36) 50 (15) KW Maximum Air Throw-Ft. (m) CEILING Minimum 2 Ft. Maintenance Access Two 3/8-16 threaded rods (not supplied with the heater) Wall mounting bracket Ceiling mounting bracket WALL WALL 6 In. Y Airflow X Minimum W Z 6 Ft. Minimum to floor (any mounting) Motor Data Description RPM Standard Premium Airflow - CFM (cubic meters/hr) Noise Level (dB) 1-12 KW 12.5-20 KW 25-38.4 KW 1-12 KW 12.5-20 KW 25-38.4 KW 1200 362 (615) 1342 (2280) 1237 (2102) 64 68 68 1800 618 (1050) 1774 (3014) 1635 (2778) 75 84 84 27 F A N - F O R C E D H E A T E R S 238 Series Industrial Unit Heater For Non-Hazardous Areas For Non-Corrosive Areas Heater Listing KW 3 5 7.5 9 10 12 12.5 15 20 25 30 35 38.4 Motor Volts Phase Total Amps (1) Approximate Air Temperature Rise °F (°C) HP Volts Phase Catalog Number 208 240 480 208 1 1 1 3 17 15 8 11 21 (12) 21 (12) 21 (12) 21 (12) 1/4 1/4 1/4 1/4 208 240 480 208 1 1 1 1 HX-238-UT03C HX-238-UT03J HX-238-UT03T HX-238-UT03D 240 480 208 240 480 208 240 480 208 240 480 208 3 3 1 1 1 3 3 3 1 1 1 3 10 5 27 23 12 16 15 8 39 34 17 23 21 (12) 21 (12) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 53 (29) 53 (29) 53 (29) 53 (29) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 240 480 208 240 480 208 240 480 208 240 480 208 1 1 1 1 1 1 1 1 1 1 1 1 HX-238-UT03K HX-238-UT03U HX-238-UT05C HX-238-UT05J HX-238-UT05T HX-238-UT05D HX-238-UT05K HX-238-UT05U HX-238-UT08C HX-238-UT08J HX-238-UT08T HX-238-UT08D 240 480 208 240 480 208 240 480 240 480 3 3 1 1 1 3 3 3 1 1 21 11 46 40 20 28 24 12 44 22 53 (29) 53 (29) 64 (36) 64 (36) 64 (36) 64 (36) 64 (36) 64 (36) 70 (39) 70 (39) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 240 480 208 240 480 208 240 480 240 480 1 1 1 1 1 1 1 1 1 1 HX-238-UT08K HX-238-UT08U HX-238-UT09C HX-238-UT09J HX-238-UT09T HX-238-UT09D HX-238-UT09K HX-238-UT09U HX-238-UT10J HX-238-UT10T 208 3 30 70 (39) 1/4 208 1 HX-238-UT10D 240 3 27 70 (39) 1/4 240 1 HX-238-UT10K 480 480 208 240 480 208 240 480 208 240 480 480 480 480 480 480 3 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 14 27 36 32 16 37 33 17 44 39 20 26 32 38 44 48 70 (39) 62 (34) 62 (34) 62 (34) 62 (34) 31 (17) 31 (17) 31 (17) 38 (21) 38 (21) 38 (21) 35 (19) 66 (37) 79 (44) 61 (34) 70 (39) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 480 480 208 240 480 208 240 480 208 240 480 480 480 480 480 480 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 HX-238-UT10U *HX-238-UT12T *HX-238-UT12D *HX-238-UT12K *HX-238-UT12U HX-238-UL13D HX-238-UL13K HX-238-UL13U HX-238-UL15D HX-238-UL15K HX-238-UL15U *HX-238-UL20U HX-238-UA25U HX-238-UA30U *HX-238-UA35U *HX-238-UA39U * Premium motor comes standard with heater. (1) Total Amps = Heating element amps and motor amps. (2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery. 28 Availability Code (2) AS 240 Series F A N - F O R C E D Unit Heater H E A T E R S The 240 Series unit heater is available in 50 standard models with ratings up to 50 KW at voltages of 208, 240, 277, and 480 single or three-phase. They are available with a wide variety of factory built-in or field-installed options. Temperature Control: Single-stage or two-stage control with built-in or remote-mounted thermostats are available on all heaters. Control Options: Available as factory built-in or fieldinstalled to meet job specifications. Custom KW’s: Custom KW’s are available up to 50 KW. Applications • Factories • Shipping and Receiving Areas • Garages • Storage Areas • Mechanical Rooms • Warehouses • Pump Houses • Workshops • Service Areas in Air Handling Units Discharge Direction: Heater can be mounted for horizontal or vertical discharge using an optional universal wall/ ceiling mounting bracket or with field-furnished threaded rods for ceiling mounting. Color Options: The standard color is camel. Six optional colors are available: grey, yellow, red, white, blue or textured beige. Heaters may also be supplied with unpainted corrosion resistant galvanized steel. See back cover for color samples. Standard Construction Features Heating Elements - Industrial grade, 0.475” diameter steel sheath with brazed copper plated steel fins and epoxy sealed ends. Draw-thru airflow design pulls air across the heating elements to ensure cool element operation and even air distribution resulting in long element life. Housing - Heating elements and motor are enclosed in a heavy gauge galvanized steel cabinet with a durable polyester powder coat finish. Outlet Grille - Individually adjustable louvers are provided to direct airflow. A protective outlet fan guard is provided to prevent insertion of foreign objects. Fan Motor - Permanently lubricated and thermally protected motor. Built-in Controls - All units include an automatic reset thermal cutout that will de-energize the heater if an overtemperature condition occurs. A manual reset thermal cutout, in addition to an automatic reset thermal cutout, is standard on heaters 10 KW and above. A fan relay is provided to allow the elements to heat up before fan startup and purges the heater of residual heat after shutdown. A 24-volt transformer and disconnecting contactor are provided on most heaters. Single-phase heaters rated at 5 KW or less have line voltage controls; 24-volt control and contactor are available. Power fusing is standard on all heaters rated over 48 amps. Mounting – Universal horizontal or vertical discharge. Optional diffusers are available for vertical discharge. An Anemostat diffuser can be used to provide draftfree air movement at lower mounting heights. For higher mounting heights, radial diffuser with adjustable fins can be used to increase floor coverage or adjusted for a vertical down blast of air. 29 240 Series H E A T E R S Unit Heater Factory Built-in Options Code Consult Factory D F O R C E D - A I R F M P (1) R1 R2 (1) (2) S1 S2 (1) T V1* V2 X (2) Description Custom KW - CONSULT FACTORY Power disconnect switch Fusing under 48 Amps, not available on heaters 3 to 10 KW Manual Reset Cutout (In addition to automatic cutout) on heaters up to 10KW “Heater On” Pilot Light Built-in 24V transformer and contactor for 3 to 5 KW, single phase heaters. 120V Transformer to replace 24V Transformer, fused secondary and grounded Summer Fan Switch Summer Fan Switch – Remote Pilot Duty Built-in Thermostat - 1 - Stage Built-in Thermostat - 2 - Stage (Option ‘X’ required) Anemostat (Cone) Diffuser Radial Diffuser 2-Stage Control * consult factory for lead times (1) When specifying Option ‘P’ (pilot light) or Option ‘S2’ (remote fan switch) or Option ‘R2’ (120V control) with 3 kW to 5 kW single phase heaters, Option ‘R1’ must be also specified. (2) Option ‘R2’ (120V control) and Option ‘X’ (2-stage control) cannot be combined on heaters rated up to 5 KW. (3) When specifying these options with 3 to 5 KW single-phase heaters, Option ‘R1’ must also be specified. (4) When specifying this option, with any heater, option ‘R2’ must also be specified. Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description 1024155 1024156 1024157 1024152 1024153 1024154 1023941 1024059 1024060 1024162 Anemostat (Cone) Diffuser up to 5 kW Anemostat (Cone) Diffuser over 5 kW up to 20 kW Anemostat (Cone) Diffuser over 20 kW Radial Diffuser up to 5 kW Radial Diffuser over 5 kW up to 20 kW Radial Diffuser over 20 kW Horizontal Dust Shield up to 10 kW Horizontal Dust Shield over 20 kW up to 20 kW Horizontal Dust Shield over 20 kW Disconnect Switch, 600V, Three-Pole, 40 Amp 1024163 Disconnect Switch, 600V, Three-Pole, 80 Amp 1024164 1024166 1024167 1024168 (1)(3) 1024169 (2)(4) 1024170 1024171 1024172 (1)(3) Disconnect Switch, 600V, Three-Pole, 100 Amp Built-in Thermostat - 1 - Stage Built-in Thermostat - 2 - Stage (Option ‘X’ required) Heater On Pilot Light (24V) Heater On Pilot Light (120V) Summer Fan Switch - Built-in up to 277V Summer Fan Switch- Built-in, over 277V Summer Fan Switch - Remote, 24V Control Max Mtg. Height ft. (m) A ft (m) B ft (m) 10 (3.0) 15 (4.6) 20 (6.1) 25 (7.6) 17 (5.2) 28 (8.5) 38 (11.6) 68 (20.7) — — — — 10 (3.0) 15 (4.6) 20 (6.1) 25 (7.6) 22 (6.7) 40 (12.2) 53 (16.2) 85 (25.9) 12 (3.7) 20 (6.1) 27 (8.2) 45 (13.7) 9 (2.7) 13 (4.0) 17 (5.2) 21 (6.4) 17 (5.2) 29 (8.8) 40 (12.2) 68 (20.7) — — — — OPEN up to 5 kW over 5 up to 10 kW over 10 up to 20 kW over 20 up to 50 kW 10 (3.0) 15 (4.6) 20 (6.1) 25 (7.6) 20 (6.1) 30 (9.1) 38 (11.6) 65 (19.8) — — — — 45° Vertical Mounting Air Pattern Table up to 5 kW over 5 up to 10 kW over 10 up to 20 kW over 20 up to 50 kW 9 (2.7) 11 (3.4) 15 (4.5) 18 (5.5) 24 (7.3) 36 (11.0) 46 (14.0) 78 (23.8) — — — — Description WITHOUT DIFFUSER For a straight downward air pattern, directional louvers can be removed in order to maximize airflow. up to 5 kW over 5 up to 10 kW over 10 up to 20 kW over 20 up to 50 kW DIRECTIONAL LOUVERS (standard) Provides a directional (straight line) airflow which results in a rectangular air pattern. Louvers can be adjusted through a 35 degree range of motion up to 5 kW over 5 up to 10 kW over 10 up to 20 kW over 20 up to 50 kW ANEMOSTAT DIFFUSER Ideal for low mounting heights. Fabricated using 3 diverging hollow cones which disperse heat to the floor area at a minimum velocity for comfort. up to 5 kW over 5 up to 10 kW over 10 up to 20 kW over 20 up to 50 kW RADIAL DIFFUSER Ideal for high ceiling mounting. Louvers can be adjusted to direct airflow straight down when fully open to 45 degrees in a radial pattern which increases floor coverage by approxiately 20%. 30 Used on 240 Series Heater Listing KW 2.5 3.7 3.8 5 6.7 7.5 9.9 10 13.2 13.3 15 19.9 20 25 33.3 37.5 Ph 208 240 277 208 240 277 480 208 240 208 240 277 208 240 480 208 240 277 208 240 208 240 480 208 240 277 208 240 480 277 208 240 208 240 480 208 240 240 277 208 480 208 240 480 208 240 480 208 240 480 1 1 1 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 1 1 3 3 3 1 1 1 3 3 3 1 1 1 3 3 3 1 3 1 1 3 3 3 3 3 3 3 3 3 3 3 Total Amps* 12.30 10.7 9.40 16.17 14.05 12.21 4.66 10.85 9.44 24.34 21.13 18.35 14.18 12.33 6.22 32.91 28.62 24.79 36.80 32.00 21.52 18.74 9.39 48.30 42.37 36.70 28.46 24.76 12.40 48.35 64.79 56.27 42.48 36.93 18.44 96.52 48.72 84.18 72.90 56.36 24.46 70.90 61.64 30.77 93.93 81.61 40.75 105.59 91.71 45.80 Approx. Air Temperature Rise °F (°C) 27 (15) 27 (15) 46 (26) 37 (21) 49 (27) 52 (29) 60 (33) 49 (27) 61 (34) 2-Stage Control Std. Control Voltage Unit Size Catalog Number (2) 1B 1B 1B 1B 1B 1B 1A 1A 1A 1B 1B 1B 1A 1A 1A 1B 1B 1B 1B 1B 1A 1A 1A 1B 1B 1B 1A 1A 1A 1B Standard Standard 1B 1B 1B Standard 1B Standard Standard Standard 1B Standard Standard 1B Standard Standard 1B Standard Standard 1A 208 240 277 208 240 277 24 24 24 208 240 277 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 HX-240-U1025C HX-240-U1025J HX-240-U1026N HX-240-U1033C HX-240-U1033J HX-240-U1033N HX-240-U1037U HX-240-U1038D HX-240-U1038K HX-240-U1050C HX-240-U1050J HX-240-U1050N HX-240-U1050D HX-240-U1050K HX-240-U1050U HX-240-U2067C HX-240-U2067J HX-240-U2067N HX-240-U2075C HX-240-U2075J HX-240-U2075D HX-240-U2075K HX-240-U2075U HX-240-U2099C HX-240-U2100J HX-240-U2100N HX-240-U2100D HX-240-U2100K HX-240-U2100U HX-240-U3132N HX-240-U3133C-X HX-240-U3133J-X HX-240-U3150D HX-240-U3150K HX-240-U3150U HX-240-U3199C-X (1) HX-240-U3199K HX-240-U3200J-X (1) HX-240-U3200N-X HX-240-U3200D-X HX-240-U3200U HX-240-U4250D-X HX-240-U4250K-X HX-240-U4250U HX-240-U4333D-X HX-240-U4333K-X HX-240-U4333U HX-240-U4375D-X HX-240-U4375K-X HX-240-U4375U H E A T E R S 3.3 Volts F O R C E D - A I R Unit Heater *Total Amps = Heating element amps and motor amps. 1. Disconnect switch unavailable on HX-240-U3199C-X and HX-240-U3200J-X 2. All Standard heaters are supplied with 24V transformer and contactor except up to 5 KW single phase units. Optional low voltage transformer and contactor are available for these heaters, see Factory Built-in Option ‘R1’. 2-stage heaters can be field wired as single stage. 1A = Optional 2-stage control, unbalanced (option X) 1B = Optional 2-stage control, balanced (option X). 31 240 Series H E A T E R S Unit Heater Remote Thermostat Selection Chart F O R C E D - A I R KW Catalog Number Volts Ph 1-Stage Line Voltage HX-240-U1033C 208 1 1007014 1006998 (a) 1007030 (a) HX-240-U1033J 240 1 1007014 1006998 (a) 1007030 (a) HX-240-U1033N 277 1 1007014 1006998 (a) 1007030 (a) HX-240-U1037U 480 3 NA 1006998 1007030 HX-240-U1038D 208 3 NA 1006998 1007030 HX-240-U1038K 240 3 NA 1006998 1007030 HX-240-U1050C 208 1 NA 1006998 (a) 1007030 (a) HX-240-U1050J 240 1 1007014 1006998 (a) 1007030 (a) HX-240-U1050N 277 1 1007014 1006998 (a) 1007030 (a) 1006998 1007030 3.3 3.7 3.8 5 All Other 240 Series Heaters NA 1-Stage Low Voltage (b) 2-Stage Low Voltage (b) (a) Add option ‘R1’ for 24V control on these units. (b) Option ‘R2’ is unavailable with any HEATREX supplied remote low voltage thermostats. Mounting Brackets Catalog Number Description 1024149 Universal wall & ceiling mounting bracket up to 10 KW 1024150 Universal wall & ceiling mounting bracket over 10 KW up to 20 KW 1024151 Universal wall & ceiling mounting bracket over 20 KW Finish/Color Options Code Color Unit Size CFM Installed Weight lb (kg) Max. Air Throw ft. (m) Yellow 1 350 25 (11.3) 15 (4.6) Red 2 650 40 (18.1) 18 (5.5) 3 1500 55 (25) 41 (12.5) 4 3100 155 (70.3) 62 (18.9) None Camel A0 Grey A1 A2 32 Finish Airflows, Weights and Air Throw Polyester Powder Coat A3 White A4 Blue A5 Steel (unpainted) Galvanized A7 Polyester Powder Coat Beige 926 Series The 926 Series unit heater is designed for industrial and commercial applications. • Large Capacity: Heavy-duty construction with ratings up to 60 KW at 2,000 CFM. • Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit. Field connections and built-in controls are easily accessed in the side-mounted control compartment. Applications •Garages •Vestibules • Mechanical Rooms •Warehouses •Stairwells •Workshops • Discharge Direction: The heater may be mounted horizontally using one of two brackets (supplied) or vertically using four threaded rods (not included). H E A T E R S • C ontrol Options: Wide range of factory built-in or field-installed control options to meet job specifications. F O R C E D - A I R Unit Heater Standard Construction Features Heating Elements – Industrial grade stainless steel tubular elements in 2-10 KW units and steel finned tubular elements in 15-60 KW units. Housing – Cabinet is constructed of 18 and 20-gauge galvanized steel finished with durable almond polyester powder paint. Outlet Grille – The outlet grille has individually adjustable louvers to direct airflow. A protective outlet mesh screen, provided on 2-30 KW heaters, allows for lower mounting heights. Fan Motor – Totally enclosed, thermally protected motor with factory-lubricated ball bearings operates at 58 dBA (2-10 KW), 67 dBA (15-30 KW) or 77 dBA (40-60 KW). Blow-through design reduces motor operating temperature for longer life. Built-in Controls – Include 240/208 volt control circuit (with transformer if necessary), automatic reset thermal cutout, fan override and factory-installed contactor. Power fusing is supplied for heaters over 48 amps. Mounting Bracket – Wall and ceiling bracket provided with each unit under 40 KW for horizontal mounting. 40-60 KW heaters furnished with four corner support brackets for ceiling mounting. Installation Requirements – For best performance, do not install unit heaters above recommended maximum mounting heights of 2-10 KW, 8-feet; 15-30 KW, 10-feet; 40-60 KW, 15-feet. All but 40-60 KW heaters can be installed at lower mounting heights. Minimum height for 40-60 KW heaters is 8-feet. Maximum ambient room temperature for proper operation is 85°F. 33 926 Series H E A T E R S Unit Heater Factory Built-in Options Code F O R C E D - A I R C Field-Installed Options (shipped loose for field installation into heater) Description Three Pole Contactor D1 Disconnect Switch 40 Amp Catalog Number D2 Disconnect Switch 80 Amp 926-124513 Diffuser cone (2-10 kW) D5 Disconnect Switch 100 Amp 926-124514 Diffuser cone (15-30 kW) G Fusing 926-161077 Diffuser cone (40-60 kW) Description M Manual Reset 926-124515 Thermostat Kit R1 24V Relay 926-124516 24V Relay Kit R2 24V Relay with Transformer (1) 926-124518 24V Relay Kit with Transformer T Thermostat (2) U Fan “ON” Switch V 120V Control, fused secondary and grounded (1) Add option “R2” when a low voltage remote thermostat is required. (2) Not available with heater part number 926U10000CA. Remote Room Thermostat – See page 99 Dimensions, Airflows and Weights A B C D E F G H I Weight In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) In. (mm) lb (kg) 2-10 12 (305) 16-1/2 (419) 17 (432) 14-1/16 (357) 11-7/16 (290) 19 (490) 12 (305) 4-7/8 (123) 16-7/8 (428) 45 (20) 15-30 18 (444) 21-7/8 (556) 23 (572) 19 (470) 16 (407) 25 (630) 12 (305) 5-13/16 (148) 23-5/16 (592) 85 (39) 40-60 23 (585) 25 (641) 34 (870) — — 36-3/8 (924) 12 (305) 12 (305) 35 (890) 150 (68) KW Wall Bracket 4 Threaded Rods 1/2-13 UNC D Support Brackets Ceiling Bracket E H I B 34 A G (MIN) F C 40-60 KW 926 Series Heater Listing KW 2 4 5 7.5 10 CFM HP RPM Voltage Catalog Number HX-926U02000CA HX-926U02000DA HX-926U02000JA HX-926U02000KA HX-926U02000NA HX-926U02000TA HX-926U02000UA HX-926U03000CA HX-926U03000DA HX-926U03000JA HX-926U03000KA HX-926U03000NA HX-926U03000TA HX-926U04000UA HX-926U04000CA HX-926U04000DA HX-926U04000JA HX-926U04000KA HX-926U04000NA HX-926U04000TA HX-926U04000UA HX-926U05000CA HX-926U05000DA HX-926U05000JA HX-926U05000KA HX-926U05000NA HX-926U05000TA HX-926U05000UA HX-926U07500CA HX-926U07500DA HX-926U07500JA HX-926U07500KA HX-926U07500NA HX-926U07500TA HX-926U07500UA Volts Phase 208 208 240 240 277 480 480 208 208 240 240 277 480 480 208 208 240 240 277 480 480 208 208 240 240 277 480 480 208 208 240 240 277 480 480 1 3 1 3 1 1 3 1 3 1 3 1 1 3 1 3 1 3 1 1 3 1 3/1* 1 3/1* 1 1 3 1 3/1* 1 3/1* 1 1 3 10.3 6.3 9.0 5.5 7.9 4.9 3.1 15.1 9.0 13.2 7.9 11.5 7.0 4.3 19.9 11.8 17.4 10.3 15.1 9.0 5.5 24.7 14.6 21.5 12.7 18.8 11.1 6.7 36.8 21.5 32.0 18.7 27.8 16.3 9.7 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 9 (5) 9 (5) 9 (5) 9 (5) 9 (5) 9 (5) 9 (5) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 18 (10) 18 (10) 18 (10) 18 (10) 18 (10) 18 (10) 18 (10) 23 (13) 23 (13) 23 (13) 23 (13) 23 (13) 23 (13) 23 (13) 34 (19) 34 (19) 34 (19) 34 (19) 34 (19) 34 (19) 34 (19) 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 240/208 208 1 48.8 700 45 (25) 1/30 1550 240/208 HX-926U10000CA 208 240 240 480 480 3 1 3/1* 1 3 28.5 42.4 24.8 21.5 12.7 700 700 700 700 700 45 (25) 45 (25) 45 (25) 45 (25) 45 (25) 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 240/208 240/208 240/208 240/208 240/208 HX-926U10000DA HX-926U10000JA HX-926U10000KA HX-926U10000TA HX-926U10000UA H E A T E R S 3 Motor Data Approximate Air Temperature Rise °F (°C) Total Amps (1) F O R C E D - A I R Unit Heater (1) Total Amps = Heating element amps and motor amps. Other voltages available. Consult factory. Only available with almond finish. * Can be converted from 3 to 1-phase in the field. 35 926 Series H E A T E R S Unit Heater Heater Listing (cont.) F O R C E D - A I R KW 15 20 25 30 40 50 60 Volts Phase Total Amps (1) 208 208 240 240 480 480 208 208 240 240 480 480 208 208 240 240 480 480 480 480 480 480 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 3 3 3 3 73.2 42.7 63.6 37.2 32.2 18.9 97.3 56.6 84.4 49.2 42.6 25 121.3 70.5 105.3 61.2 53 31 37 49.6 61.6 73.7 CFM HP RPM Voltage Catalog Number 1300 1300 1300 1300 1400 1400 1300 1300 1300 1300 1400 1400 1300 1300 1300 1300 1400 1400 1400 2000 2000 2000 36 (20) 36 (20) 36 (20) 36 (20) 34 (19) 34 (19) 49 (27) 49 (27) 49 (27) 49 (27) 45 (25) 45 (25) 61 (34) 61 (34) 61 (34) 61 (34) 56 (31) 56 (31) 68 (38) 64 (18) 80 (27) 96 (36) 1/8 1/8 1/30 1/30 1/6 1/6 1/8 1/8 1/8 1/8 1/6 1/6 1/8 1/8 1/8 1/8 1/6 1/6 1/6 3/4 3/4 3/4 1550 1550 1550 1550 1725 1725 1550 1550 1550 1550 1725 1725 1550 1550 1550 1550 1725 1725 1725 1140 1140 1140 240/208 240/208 240/208 240/208 480 (1 ph) 480 (1 ph) 240/208 240/208 240/208 240/208 480 (1 ph) 480 (1 ph) 240/208 240/208 240/208 240/208 480 (1 ph) 480 (1 ph) 480 (1 ph) 480 (3 ph) 480 (3 ph) 480 (3 ph) HX-926U15000CA HX-926U15000DA HX-926U15000JA HX-926U15000KA HX-926U15000TA HX-926U15000UA HX-926U20000CA HX-926U20000DA HX-926U20000JA HX-926U20000KA HX-926U20000TA HX-926U20000UA HX-926U25000CA HX-926U25000DA HX-926U25000JA HX-926U25000KA HX-926U25000TA HX-926U25000UA HX-926U30000UA HX-926U40000UA HX-926U50000UA HX-926U60000UA (1) Total Amps = Heating element amps and motor amps. Other voltages available. Consult factory. Only available with almond finish. 36 Motor Data Approximate Air Temperature Rise °F (°C) 924 Series The 924 Series unit heater is an economical choice for commercial heating applications. •C ompact Design: Ideal for primary or spot heating applications. Units can be wall or ceiling-mounted for horizontal airflow. • Built-in Adjustable Thermostat: Minimum temperature setting on thermostat can be used to disable the heater. Applications • Basements • Storage Rooms • Entrances • Workshops • Garages • Service Areas in Air Handling Units • Mechanical Rooms H E A T E R S •V ersatility: Three different heater KW ratings can be field converted to either 240 or 208 single-phase power. F O R C E D - A I R Unit Heater Standard Construction Features Heating Elements – Stainless steel tubular elements. Housing – Cabinets are constructed of 20-gauge galvanized steel with an almond polyester powder paint finish. Fan/Motor – The fan supplies 300 CFM at 51 dBA. The motor is permanently lubricated and totally enclosed. Outlet Grille – The outlet grille has adjustable louvers to direct airflow and a protective screen for additional safety. Built-in Controls – Automatic reset thermal cutout and adjustable thermostat. Mounting Bracket – A universal mounting bracket for either wall or ceiling installation allows for 360° rotation of the heater. Dimensions, Airflows and Weights Approximate Air Temperature Rise °F (°C) Weight lb (kg) Catalog Number 300 21/16 (12/9) 20 (9) HX-924U02000VA 300 32/24 (18/13) 20 (9) HX-924U03000VA 300 53/40 (29/22) 20 (9) HX-924U05000VA Total Amps (1) CFM 1 8.7/7.6 1 12.9/11.2 1 21.2/18/4 Watts Volts Phase 2000/1500 240/208 3000/2250 240/208 5000/3750 240/208 (1)Total Amps = Heating element amps and motor amps. Only available with almond finish. 11" 8" 3-1/2" 15-1/2" 12-1/4" 12" 10-1/2" 37 928 Series H E A T E R S Vertical Unit Heater F O R C E D - A I R The 928 Series unit heater is designed to heat buildings with high ceilings. It may also be used to recirculate warm air that builds up near ceilings. 928 Series heaters can be used as primary, supplemental or dual heating systems in commercial or industrial buildings. Applications • Aircraft Hangars •Malls •Factories • Power Generating Stations •Garages • Shipping and Receiving Areas •Gyms •Warehouses • Vertical Airflow: Suitable for applications in high bay industrial buildings where columns, machinery or warehouse stock would obstruct horizontal air movement. • Air Distribution Patterns: Three optional air diffusers produce different air distribution patterns to accommodate various applications. • High Bay Areas Standard Construction Features Heating Elements – Steel finned tubular elements are grounded for extra safety. Housing – Cabinet is constructed of 18-gauge galvanized steel with an almond polyester powder paint finish. Fan Motor – Quiet, totally enclosed motor is thermally protected. Factory Built-in Options Code Description Installation Requirements – Do not install heater closer than 24 inches from walls and ceiling. Mount heaters out of reach, at least eight feet from the floor. Field-Installed Options (shipped loose for field installation into heater) D1 Disconnect Switch 40A, 600V, 3-Pole D2 Disconnect Switch 80A, 600V, 3-Pole R1 24V Relay 928-124521 Single Cone Diffuser 5-10 KW R2 24V Relay with Transformer 928-124522 Single Cone Diffuser 15-30 KW X 120V Control, fused secondary and grounded 928-124523 Triple Cone Diffuser 5-10 KW 928-124524 Triple Cone Diffuser 15-30 KW 928-124525 Jet Cone Diffuser 5-10 KW 928-124526 Jet Cone Diffuser 15-30 KW 928-124527 24V Relay Kit 928-124528 24V Relay Kit with Transformer-208V 928-124529 24V Relay Kit with Transformer-240V Remote Room Thermostat – See page 99 38 Built-in Controls – Contactor, fan override, terminal block for remote fan control and linear automatic reset thermal cutout. Catalog Number Description Vertical Unit Heater Air Distribution Patterns Without Cone Single Cone H E A T E R S H H F O R C E D - A I R 928 Series S S Triple Cone Jet Cone H H S S Maximum Mounting Height Without Cone KW Single Cone Triple Cone Jet Cone H S H S H S H S Ft (m) Ft (m) Ft (m) Ft (m) Ft (m) Ft (m) Ft (m) Ft (m) 5-10 12 (4) 19 (6) 8 (3) 22 (7) 10 (3) 31 (10) 16 (5) 20 (6) 15-30 18 (6) 20 (9) 10 (4) 33 (10) 14 (4) 43 (13) 22 (7) 26 (9) 39 928 Series H E A T E R S Vertical Unit Heater F O R C E D - A I R 24" C Support Brackets B 24" A B C In. (mm) In. (mm) In. (mm) 5-10 KW 23-1/8 (587) 8 (203) 6-15/16 (176) 15-30 KW 30-1/4 (768) 12-3/16 (310) 6-11/16 (170) Model (Without Cone) 40 A 928 Series Heater Listing Motor Data CFM Approx. Air Temp. Rise °F (C°) HP RPM Voltage Volts Phase Weight Ib (kg) Catalog Number 3.2 480 3 4.7 450 22 (12) 1/25 1050 4.8 480 3 6.6 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C03200UA 208/240 75 (34) HX-928C04800UA 208 1 24.9 450 34 (19) 1/25 208 3 14.7 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000CA 1050 208/240 75 (34) HX-928C05000DA 240 1 21.7 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000JA 240 3 12.9 450 480 3 8.6 600 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000KA 34 (19) 1/25 1050 208/240 75 (34) HX-928C06400UA 208 3 21.7 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500DA 240 1 240 3 32.1 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500JA 18.9 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500KA 480 3 12.5 1200 25 (14) 1/6 1140 208/240 100 (48) HX-928C09600UA 208 3 28.6 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000DA 240 1 42.5 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000JA 240 3 24.9 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000KA 480 3 16.3 1200 34 (19) 1/6 1140 208/240 100 (48) HX-928C12800UA 208 3 42.6 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000DA 240 1 63.4 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000JA 240 3 37 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000KA 16 480 3 20.2 1600 32 (18) 1/6 1140 208/240 100 (48) HX-928C16000UA 19.2 480 3 24 1600 38 (21) 1/6 1140 208/240 100 (48) HX-928C19200UA 208 3 56.5 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000DA 240 1 84.2 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000JA 240 3 49.1 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000KA 208 3 70.4 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000DA 240 1 105.0 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000JA 240 3 61.1 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000KA 208 3 84.2 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000DA 240 1 125.9 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000JA 240 3 73.2 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000KA 5 6.4 7.5 9.6 10 12.8 15 20 25 30 H E A T E R S KW Total Amps (1) F O R C E D - A I R Vertical Unit Heater (1) Total Amps = Heating element amps and motor amps. Only available with almond finish. 41 Comparison Chart H E A T E R S Wall, Ceiling and Floor Heaters 935 933 F O R C E D - A I R 934 932 940 930 42 Features Architectural Wall 933 Series Commercial Wall 932 Series European Wall 935 Series Hybrid Convection 940 Series Wall 934 Series Register Wall 930 Series Typical Applications Entryways Offices Reception areas Guard houses Offices Stairwells Offices Restrooms Offices Restrooms Condominiums Small offices Storage rooms Hallways Stairwells Wattage Range up to 8,000 up to 12,000 up to 1,500 up to 2,000 up to 2,000 up to 2,000 Voltages up to 480/1 up to 480/3 up to 240/1 up to 240/1 up to 240/1 up to 240/1 Airflow CFM up to 320 up to 480 up to 70 Convection up to 80 up to 80 Steel finned tubular Steel finned tubular Element Type Steel finned tubular Steel finned tubular Steel finned tubular Fast Response Coil Element Standard Construction 1/8” thick extruded aluminum grille 18-gauge steel grille 20-gauge steel grille Cast Aluminum grille 20-gauge steel grille 20-gauge steel grille Finish Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Mounting Surface or recessed Surface or recessed Surface or recessed Surface or recessed Surface or recessed Surface or recessed Custom Colors Yes Yes Yes Yes Yes Yes Agency Approvals CSAus CSAus CSAus CSAus CSAus CSAus Comparison Chart 936 937 922 939 H E A T E R S 931 F O R C E D - A I R Wall, Ceiling and Floor Heaters 938 Cabinet 922 Series Fan-Forced Ceiling 936 Series Fan Forced Ceiling 937 Series Commercial Ceiling 931 Series Toe-Space 938 Series Floor Insert 939 Series Classrooms Hallways Meeting rooms Classrooms Day care Reception areas Classrooms Day care Reception areas Entryways Hallways Restrooms Kitchens Reception areas Under sliding doors Under windows up to 24,000 up to 10,000 up to 5,000 up to 8,000 up to 1,000 up to 1,500 up to 480/3 up to 480/3 up to 480/3 up to 480/1 up to 240/1 up to 240/1 up to 1,000 up to 700 up to 450 up to 320 80 80 Steel finned tubular Stainless steel finned tubular aluminum fins Stainless steel finned tubular aluminum fins Steel finned tubular Steel finned tubular Steel finned tubular 18-gauge steel and extruded aluminum grille 21-gauge steel grille 21-gauge steel grille 18-gauge steel grille 20-gauge steel grille 20-gauge steel body and 14-gauge grille Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Surface, recessed or ceiling Surface or T-bar Recessed or T-bar Surface, recessed or T-bar Recessed under cabinet Recessed in floor Yes Yes Yes Yes Yes Yes CSAus CSAus CSAus CSAus CSAus CSAus 43 933 Series H E A T E R S Architectural Wall Heater F O R C E D - A I R The 933 Series fan-forced wall heater is designed for commercial and industrial areas requiring higher KW ratings and quick recovery. The unit provides a burst of heat in areas affected by cold drafts or wide temperature swings. • Efficient Operation: The fan draws air into the top of the grille and discharges warm air downward to distribute heat and keep floors warm and dry. High CFMs create air circulation within the room to provide uniform temperatures. • E xtended Capacity: The 933 Series is available with one or two modules and ratings up to 8,000 W and 320 CFM. Applications •Entryways •Restrooms •Garages •Stairwells • Guard Houses •Vestibules •Offices • Reception Areas Standard Construction Features Heating Elements – Steel finned tubular elements. Outlet Grille – The WAI has an architectural extruded aluminum grille in a choice of eight polyester powder paint finishes. The closely spaced, heavy bar grille design prevents insertion of foreign objects. The tamperproof thermostat adjustment is concealed behind the front cover. Built-in Controls – Automatic reset thermal cutout, fan override and tamperproof thermostat (32° to 120°F). 44 Fan Motor – Permanently lubricated, totally enclosed fan operates at a low 58 dBA. Installation Requirements – Standard supply wiring rated at 60°C can be used for installation of wall heaters. Heater must be installed at least ten inches from the floor and adjacent walls. Rough in Dimensions – • 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high x 4-1/2” deep. • 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high x 4-1/2” deep. 933 Series Field-Installed Options Factory Built-in Options Code (shipped loose for field installation into heater) Description Catalog Number Description Disconnect Switch 600V, Three-pole, 40 Amp D3 Disconnect Switch 277V, Double-pole, 20 Amp 933-124501 Surface Mounting Box (1500-4800 W) R1 24 Relay (1) 933-158471 Surface Mounting Box (6000-8000 W) R2 24V Relay with Transformer (1) 933-151114 1” Semi Recessed Trim Kit (1500-4800 W) Fan On/Auto Switch 933-166530 1” Semi Recessed Trim Kit (6000-8000 W) 933-151115 2” Semi Recessed Trim Kit (1500-4800 W) 933-166531 2” Semi Recessed Trim Kit (6000-8000 W) S3 (1) A built-in thermostat will not be supplied when option R1 or R2 are selected. Consult the factory if built-in thermostat is required with these options. Add color code to end of catalog number. (See next page for codes.) Required Wall Depth Opening 4-5/16" H E A T E R S D1 F O R C E D - A I R Architectural Wall Heater Remote Room Thermostat – See page 99 4-3/16" 23" 6,000 - 8,000 Watts Side View 22-3/4" Heater Dimensions - 1,500 - 4,800 Watts 31-7/8" Double Unit - K.O. 7/8” - - - - - - Grille Dimensions Side View Front View (Without Grille) 45 933 Series H E A T E R S Architectural Wall Heater Heater Listing F O R C E D - A I R Built-in tamperproof thermostat is included. Watts Volts (1 Phase) Total Amps (1) CFM Approximate Air Temperature Rise oF (oC) Weight lb (kg) Catalog Number 1500/1125 240/208 6.6/5.8 160 30/27 (17/12) 24 (11) HX-933U01500V¶ 1500 120 12.9 160 30 (17) 28 (13) HX-933U01500B¶ 277 5.8 160 30 (17) 28 (13) HX-933U01500N¶ 1500 480 3.5 160 30 (17) 28 (13) HX-933U01500T¶ 240/208 8.7/7.6 160 40/30 (22/17) 24 (11) HX-933U02000V¶ 208 10.0 160 40 (22) 24 (11) HX-933U02000C¶ 277 7.6 160 40 (22) 28 (13) HX-933U02000N¶ 480 4.5 160 40 (22) 28 (13) HX-933U02000T¶ 240/208 12.9/11.2 160 60/45 (33/25) 24 (11) HX-933U03000V¶ 277 11.2 160 60 (33) 28 (13) HX-933U03000N¶ 480 6.6 160 60 (33) 28 (13) HX-933U03000T¶ 240/208 17.0/14.8 160 80/60 (44/33) 24 (11) HX-933U04000V¶ 208 19.6 160 80 (44) 24 (11) HX-933U04000C¶ 4000 277 14.8 160 80 (44) 28 (13) HX-933U04000N¶ 480 8.7 160 80 (44) 28 (13) HX-933U04000T¶ 4800/3600 240/208 20.4/17.7 160 96/72 (53/40) 24 (11) HX-933U04800V¶ 208 23.5 160 96 (53) 28 (13) HX-933U04800C¶ 277 17.7 160 96 (53) 28 (13) HX-933U04800N¶ 480 10.4 160 96 (53) 28 (13) HX-933U04800T¶ 240/208 25.4/22.0 320 60/45 (33/25) 50 (23) HX-933U06000V¶ 277 22.1 320 60 (33) 50 (23) HX-933U06000N¶ 480 12.9 320 60 (33) 50 (23) HX-933U06000T¶ 240/208 33.7/29.2 320 80/60 (44/33) 50 (23) HX-933U08000V¶ 208 38.9 320 80 (44) 50 (23) HX-933U08000C¶ 277 29.3 320 80 (44) 50 (23) HX-933U08000N¶ 480 17.1 320 80 (44) 50 (23) HX-933U08000T¶ 2000/1500 2000 3000/2250 3000 4000/3000 4800 6000/4500 6000 8000/6000 8000 (1) Total Amps = Heating element amps and motor amps. All models listed are single-phase. ¶Add color code to end of catalog number. Standard colors. See Color Code Chart below. Color Code Chart Code 46 Color Code Color BZ Bronze BG Beige-Grey AE Metallic Silver W White CM Metallic Charcoal A Almond NR Textured Black AL Aluminum 932 Series H E A T E R S The 932 Series fan-forced wall heater is designed for commercial and industrial areas requiring higher KW ratings and quick recovery. The unit provides a burst of heat in areas affected by cold drafts or wide temperature swings. • Efficient Operation: The fan draws air into the top of the grille and discharges warm air downward to distribute heat and keep floors warm and dry. High CFM’s create air circulation within the room to provide uniform temperatures. • Extended Capacity: The 932 Series is available with one, two or three modules and ratings up to 12,000 W at 480 CFM. F O R C E D - A I R Commercial Wall Heater Applications •Entryways •Restrooms •Garages •Stairwells • Guard Houses •Vestibules •Offices • Reception Areas Standard Construction Features Heating Elements – Steel finned tubular elements. Outlet Grille – The 932 Series has an 18-gauge steel grille with rounded corners and a polyester powder paint finish in white or almond. The external thermostat adjustment knob can be replaced with the concealing plug provided for tamperproof construction. Built-in Controls – Automatic reset thermal cutout, fan override and thermostat (32° to 120°F). Fan Motor – Permanently lubricated, totally enclosed fan operates at a low 58 dBA. Installation Requirements – Standard supply wiring rated at 60°C can be used for installation of wall heaters. Heater must be installed at least ten inches from the floor and adjacent walls. Rough in Dimensions – • 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high x 4-1/2” deep. • 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high x 4-1/2” deep. • 12000/9000 - 12000 Watt heaters: 46-5/8” wide x 19-7/8” high x 4-1/2” deep. 47 932 Series H E A T E R S Commercial Wall Heater Field-Installed Options Factory Built-in Options F O R C E D - A I R Code (shipped loose for field installation into heater) Description Catalog Number D1 Disconnect Switch 600V, Three-pole, 40 Amp D2 Disconnect Switch, 600V, Three-pole 80 Amp D3 Disconnect Switch 277V, Double-pole, 20 Amp R1 24 Relay (1) R2 24V Relay with Transformer (1) S3 Fan On/Auto Switch (1) A built-in thermostat will not be supplied when option R1 or R2 are selected. Consult the factory if built-in thermostat is required with these options. Remote Room Thermostat – See page 99 Required Wall Depth Opening 4-5/16" 4-3/16" Description 932-124500 Surface Mounting Box (1500-4800 W) 932-158211 Surface Mounting Box (6000-8000 W) 932-158212 Surface Mounting Box (12000 W) 932-146878 1” Semi Recessed Trim Kit (1500-4800 W) 932-166532 1” Semi Recessed Trim Kit (6000-8000 W) 932-166534 1” Semi Recessed Trim Kit (12000 W) 932-153670 2” Semi Recessed Trim Kit (1500-4800 W) 932-166533 2” Semi Recessed Trim Kit (6000-8000 W) 932-166535 2” Semi Recessed Trim Kit (12000 W) Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 23" Side View Grille Dimensions 1,500 - 4,800 Watts 6,000 - 8,000 Watts 16-1/8" 31-7/8" 12,000 Watts 48-5/16" 22-1/16" 1-5/16" 14-7/16" 8-5/16" 2" Side View 30-3/1 6" 2-7/8" 2-3/16" 1-5/16" 2" Top View 2" 1-5/16" 19-7/8" Side View 48 Front View (Without Grille) K.O. 7/ 46-5/8" 932 Series Heater Listing Adjustable thermostat is included. A hole plug is provided for tamperproof installations. Volts Phase Total Amps (1) CFM Approximate Air Temperature Rise oF (oC) Weight lbs (kg) Catalog Number 1500/1125 240/208 1 6.6/5.8 160 30/22 (17/12) 24 (11) HX-932U01500V¶ 120 1 12.9 160 30 (17) 28 (13) HX-932U01500B¶ 1500 277 1 5.8 160 30 (17) 28 (13) HX-932U01500N¶ 480 1 3.5 160 30 (17) 28 (13) HX-932U01500T¶ 2000/1500 240/208 1 8.7/7.6 160 40/30 (22/17) 24 (11) HX-932U02000V¶ 208 1 10.0 160 40 (22) 24 (11) HX-932U02000C¶ 277 1 7.6 160 40 (22) 28 (13) HX-932U02000N¶ 480 1 4.6 160 40 (22) 28 (13) HX-932U02000T¶ 240/208 1 12.9/11.2 160 60/45 (33/25) 24 (11) HX-932U03000V¶ 2000 3000/2250 277 1 11.2 160 60 (33) 28 (13) HX-932U03000N¶ 480 1 6.7 160 60 (33) 28 (13) HX-932U03000T¶ 4000/3000 240/208 1 17.0/14.8 160 80/60 (44/33) 24 (11) HX-932U04000V¶ 208 1 19.6 160 80 (44) 24 (11) HX-932U04000C¶ 4000 277 1 14.8 160 80 (44) 28 (13) HX-932U04000N¶ 480 1 8.7 160 80 (44) 28 (13) HX-932U04000T¶ 4800/3600 240/208 1 20.4/17.7 160 96/72 (53/40) 24 (11) HX-932U04800V¶ 208 1 23.5 160 96 (53) 28 (13) HX-932U04800C¶ 3000 4800 6000/4500 277 1 17.7 160 96 (53) 28 (13) HX-932U04800N¶ 480 1 10.4 160 96 (53) 28 (13) HX-932U04800T¶ 240/208 1 25.4/22.0 320 60/45 (33/25) 50 (23) HX-932U06000V¶ 277 1 22.1 320 60 (33) 50 (23) HX-932U06000N¶ 480 1 12.9 320 60 (33) 50 (23) HX-932U06000T¶ 8000/6000 240/208 1 33.7/29.2 320 80/60 (44/33) 50 (23) HX-932U08000V¶ 208 1 38.9 320 80 (44) 50 (23) HX-932U08000C¶ 8000 277 1 29.3 320 80 (44) 50 (23) HX-932U08000N¶ 480 1 17.1 320 80 (44) 50 (23) HX-932U08000T¶ 12000/9000 240/208 3(2) 28.9/25.0 480 80 (44) 90 (41) HX-932U12000P¶ 208 3 33.7 480 80 (44) 90 (41) HX-932U12000D¶ 6000 12000 240 3 29.3 480 80 (44) 90 (41) HX-932U12000K¶ 277 1 43.7 480 80 (44) 90 (41) HX-932U12000N¶ 480 1 25.4 480 80 (44) 90 (41) HX-932U12000T¶ 480 3 14.8 480 80 (44) 90 (41) HX-932U12000U¶ H E A T E R S Watts F O R C E D - A I R Commercial Wall Heater (1) Total Amps = Heating element amps and motor amps. (2) Single-phase is available upon request, consult factory All models listed are single-phase unless otherwise specified. Other voltages available. Consult factory. ¶Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 49 935 Series F O R C E D - A I R H E A T E R S European Style Wall Heater The 935 Series wall heater has a stylish, contemporary design with rounded corners and soft lines for an elegant appearance. This heater is ideal for areas with space restrictions and high heating requirements. • U nique Element Design: Stitched ribbon-type heating element provides instant heat for areas that need to be warmed quickly. • T hree Models: The standard single-stage heater is controlled by an optional remote line-voltage thermostat. Heater type T has a two-stage thermostat which automatically switches from minimum to maximum wattages as needed. Heater type TZ is furnished with an additional 0-60 minute mechanical timer that provides manual operation at maximum wattage during occupied periods, then resumes normal two-stage control. • Installation Flexibility: The heater can be recessed in a 2-inch by 3-inch stud wall or surface mounted without the use of adapters. (Shown with optional thermostat & timer) Applications •Entryways •Offices • Fire Station Changing Areas • Reception Areas •Restrooms Standard Construction Features Heating Elements – Stitched ribbon-type element. Fan Motor – Two-speed whisper-quiet squirrel-cage fan operates at 33 dBA with 35 CFM and 42.5 dBA with 70 CFM. Outlet Grille – The 20-gauge steel grille has a polyester powder paint finish available in white, almond, black or optional stainless steel front cover. Installation Requirements – The air outlet should be installed a minimum of 12-inches above vinyl floors. Built-in Controls – Automatic reset thermal cutout prevents overheating. Rough In Dimensions – All heaters: 11-5/8” wide x 15-1/2” high x 2” deep. 16-1/2” 3" 14-7/8” 2" 2" 4-5/16" 4” 6-15/16" 16-1/2" K.O. 7/8" 2” ▲ ▲ K.O. 1/4" ▲ 1-1/2" 4" 13-3/16" 3/4" Remote Room Thermostat – See page 99 Heater Listing Watts 50 Wall-Mounted Recessed K.O. 7/8" 1-5/8" CFM Minimum Maximum Volts (1 Phase) Total Amps (1) Minimum Maximum Maximum Air Temperature Weight lb (kg) Catalog Number - 1500 120 13.0 - 70 68 (38) 14 (6) HX-935U01500B 750 1500 120 13.0 35 70 68 (38) 14 (6) HX- 935U01500B-T 750 1500 120 13.0 35 70 68 (38) 14 (6) HX- 935U01500B-TZ - 1500/1125 240/208 6.7/5.9 - 70 68/51 (38/28) 14 (6) HX-935U01500V 750/563 1500/1125 240/208 6.7/5.9 35 70 68/51 (38/28) 14 (6) HX-935U01500V-T 750/563 1500/1125 240/208 6.7/5.9 35 70 68/51 (38/28) 14 (6) HX-935U01500V-TZ (1) Total Amps = Heating element amps and motor amps. Add W to end of catalog number for white finish, A for almond, BK for black or SS for custom stainless steel front cover. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 940 Series The 940 Series wall heater is a unique design and offers two levels of heating. The first level is convection heat with a second level of forced-air heating. This feature combines the quiet operation of convection heating for normal heating conditions and when needed a boost to forced-air heating with greater heating capacity, all in the same unit. This is well suited for condominiums when an up scale appearance is required. • Manual Power Boost: To override the automatic temperature control the heater can be easily switched into the boost heat level using the built-in timer. Boost power can be set for 5, 10, 15, 20, 25 or 30 minutes. Applications •Entryways •Offices • Fire Station Changing Areas • Reception Areas H E A T E R S • Unique Temperature Control: Built-in digital thermostat with full modulating power for convection to fan-forced heating. The power level is automatically managed by the thermostat through the full output of the heater. The electronic thermostat displays actual room temperature, with adjustable temperature settings between 50 and 95°F (10 to 35°C). When the heater is on, four graduated lines indicate the power level on the display. F O R C E D - A I R Hybrid Convection Wall Heater • Mounting: The heater can be recessed in a 2-inch by 3-inch stud wall, surface mounted or surface mounted with a color matched •Restrooms surface mounting box. Standard Construction Features Heating Elements – Instant heat nickel-chrome coil resistant wire element. Fan motor – Whisper-quiet squirrel-cage fan with factorylubricated motor. Outlet Grille – Heavy cast aluminum front cover with steel bar inlet and outlet grilles has a polyester powder paint finish available in white or almond. Installation Requirements – Do not install heater covered with vinyl. Maintain a minimum of 4-inches (102 mm) clearance below heater, 1-inch (25 mm) to adjacent walls and 48-inches (1219 mm) in front of heater. Built-in Controls – Digital display electronic thermostat with timer, automatic reset thermal cutout, temperature sensor and LED night light with on-off switch. KOE Ø 22 mm KOE Ø 7/8" 550 mm 21 5/8" 140 mm 5 1/2" 70 mm 2 3/4" 15 mm 9/16"KOE Ø 6.4 mm KOE Ø 1/4" 42 mm 1 5/8" KOE Ø 22 mm KOE Ø 7/8" 20 mm 3/4" 369 mm 14 1/2" 332 mm 13 1/16" 38 mm 1 1/2" 350 mm 13 3/4" Front view Rough In Dimensions – All heaters: 18-5/8” wide x 13-3/8” high x 2-3/4” deep. Side view Heater Listing 380 mm 15" 550 mm 21 5/8" 470 mm 18 1/2" 337 mm 13-1/4" Bottom view Recessed W all-mounte Factory Built-in Options Watts Volts (1 Ph) Amps Weight lb (kg) Catalog Number 1500 120 12.5 22.8 (10.3) HX-940U01500B 2000 240 8.3 22.8 (10.3) HX-940U02000J Standard colors – Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors – See inside of back cover for color codes to be added to end of catalog number. Code D3 Description Disconnect Switch, 277V, Double-pole, 20 Amp Field-Installed Options Catalog Number 940-213895 Description Cast Aluminum Surface Mounting Box Standard colors – Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors – See inside of back cover for color codes to be added to end of catalog number. 51 934 Series F O R C E D - A I R H E A T E R S Wall Heater The 934 Series wall heater is designed for recessed mounting into shallow 2-inch by 3-inch stud walls. It provides heat in a quiet, efficient manner. Single units can heat small areas and multiple heaters can be used in large or oddshaped rooms. • M ounting Options: Units can be surface (with optional box) or recessed mounted, vertically or horizontally, in one of four positions. A tapered recess box assures a tight fit when mounted into the wall. Applications •Breezeways •Entryways •Restrooms • Small Offices • Storage Rooms Standard Construction Features Heating Elements – Steel finned tubular elements. Outlet Grille – The louvered front grille is made from 22-gauge steel with rounded corners. The grille is finished with a polyester powder paint in white or almond. 1,000 W and 41.3 dBA at 80 CFM for all models rated above 1,000 W. Built-in Controls – Automatic reset thermal cutout. Installation Requirements - The air outlet should be installed a minimum of ten inches above vinyl floors. Fan Motor – Quiet, permanently lubricated axial fan operates at 38 dBA at 40 CFM for models up to Rough In Dimensions – All heaters: 7-3/16” wide x 14-1/8” high x 3” deep. Factory Built-in Options Code Description D3 Disconnect Switch, 277V, Double-pole, 20 Amp T1 Tamperproof Thermostat, Single-pole, 17 Amp T2 Tamperproof Thermostat, Double-pole, 17 Amp T5 Adjustable Thermostat, Single-pole, 17 Amp T6 Adjustable Thermostat, Double-pole, 17 Amp Double-pole thermostats include positive off feature. Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description 934-124647 Surface Mounting Box 934-124648 Adjustable Thermostat Kit, Single-pole, 17 Amp 934-124649 TamperproofThermostatKit,Single-pole,17Amp 934-124650 AdjustableThermostat Kit, Double-pole, 17 Amp 934-124651 TamperproofThermostatKit,Double-pole,17Amp Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Remote Room Thermostat – See page 99 52 Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 934 Series Optional Surface Mounting Surface Box Mounting Positions Heater 7-3/16” 2” x 3” Stud Wall 7-1/16” Grille 8-1/8” 16” 3" 3” 3” 3" 13-7/8” 14-1/8” H E A T E R S 8-5/32” Wall Opening F O R C E D - A I R Wall Heater 16” Heater Dimensions Heater Listing Watts Volts (1 Phase) Total Amps (1) CFM Approximate Air Temperature Rise °F (°C) Weight lb (kg) Catalog Number 500 120 4.6 40 40 (22) 9 (4) HX-934U00500B 500/375 240/208 2.3/2.0 40 40/30 (22/17) 9 (4) HX-934U00500V 750 120 6.7 40 60 (33) 9 (4) HX-934U00750B 750/563 240/208 3.3/2.9 40 60/45 (33/25) 9 (4) HX-934U00750V 1000 120 8.7 40 80 (44) 9 (4) HX-934U01000B 1000/750 240/208 4.5/3.8 40 80/60 (44/33) 9 (4) HX-934U01000V 1250 120 10.8 80 50 (28) 9 (4) HX-934U01250B 1250/938 240/208 5.4/4.7 80 50/37 (28/21) 9 (4) HX-934U01250V 1500 120 12.9 80 60 (33) 9 (4) HX-934U01500B 1500/1125 240/208 6.5/5.6 80 60/45 (33/25) 9 (4) HX-934U01500V 2000/1500 240/208 8.5/7.4 80 80/60 (44/33) 9 (4) HX-934U02000V 2000 208 9.8 80 80 (44) 9 (4) HX-934U02000C (1) Total Amps = Heating element amps and motor amps. Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 53 930 Series F O R C E D - A I R H E A T E R S Register Wall Heater (Shown with optional built-in thermostat) Applications The 930 Series register wall heater is ideal for use as a primary heat source in small areas or as supplemental heat in more spacious areas. Multiple heaters can be used to effectively heat large or oddshaped rooms. • Installation Options: Units are designed for recessed mounting into shallow 2-inch by 3-inch stud walls or surface mounting with the use of an optional box. • Safety: Finned tubular elements provide electrical isolation from accidental contact. • T emperature Control: An optional thermostat can be field installed in the heater or a remote thermostat can be used. •Hallways •Restrooms •Stairwells Standard Construction Features Heating Elements – Steel finned tubular elements. Outlet Grille – The louvered front grille is made from 20-gauge steel. The grille is finished with polyester powder paint in white or almond. 41.3 dBA at 80 CFM for all models rated above 1,000 W. Built-in Controls – Automatic reset thermal cutout. Installation Requirements – The air outlet should be installed a minimum of ten inches above vinyl floors. Fan Motor – Quiet, factory lubricated fan operates at 38 dBA at 40 CFM for models up to 1,000 W and Rough In Dimensions – All heaters: 14-1/8” wide x 7-3/16” high x 3” deep. Factory Built-in Options Code Description D3 Disconnect Switch, 277V, Double-pole, 20 Amp T1 Tamperproof Thermostat, Single-pole, 17 Amp T2 Tamperproof Thermostat, Double-pole, 17 Amp T5 Adjustable Thermostat, Single-pole, 17 Amp T6 Adjustable Thermostat, Double-pole, 17 Amp Double-pole thermostats include positive off feature. Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description 930-166766 Surface Mounting Box 930-166767 AdjustableThermostat Kit, Single-pole, 17 Amp 930-166768 TamperproofThermostatKit,Single-pole,17Amp 930-166769 AdjustableThermostatKit,Double-pole,17Amp 930-166770 TamperproofThermostatKit,Double-pole,17Amp Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Remote Room Thermostat – See page 99 54 Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 930 Series Wall-Mounted 3" Optional Surface Mounting 3" 14-1/8" Wall Opening H E A T E R S 16" Surface Box Heater 13-7/8" 7-3/16" F O R C E D - A I R Register Wall Heater 8-1/8" 8-1/8" 3" Grille 7-1/16" 16" Heater Dimensions Heater Listing Watts Volts (1 Phase) Total Amps (1) CFM 500 500/375 750 750/563 1000 1000/750 1250 1250/938 1500 1500/1125 2000 2000/1500 120 240/208 120 240/208 120 240/208 120 240/208 120 240/208 208 240/208 4.6 2.3/2.0 6.7 3.3/2.9 8.7 4.5/3.8 10.8 5.4/4.7 12.9 6.5/5.6 9.8 8.5/7.4 40 40 40 40 40 40 80 80 80 80 80 80 Approximate Air Temperature Rise °F (°C) 40 (22) 40/30 (22/17) 60 (33) 60/45 (33/25) 80 (44) 80/60 (44/33) 50 (28) 50/37 (28/21) 60 (33) 60/45 (33/25) 80 (44) 80/60 (44/33) Weight lb (kg) Catalog Number 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) 9 (4) HX-930U00500B HX-930U00500V HX-930U00750B HX-930U00750V HX-930U01000B HX-930U01000V HX-930U01250B HX-930U01250V HX-930U01500B HX-930U01500V HX-930U02000C HX-930U02000V (1) Total Amps = Heating element amps and motor amps. Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 55 922 Series F O R C E D - A I R H E A T E R S Cabinet Unit Heater The 922 Series cabinet heater offers a unique combination of quality, efficiency, reliability and flexibility. The attractive cabinet design blends into any commercial decor. • M ounting Options: The cabinet heater can be mounted on the floor, wall or ceiling. It can also be recessed into the wall or ceiling as required. Twelve air inlet and outlet combinations are available. • Simplified Maintenance: The insulated front panel is hinged to allow for easy access. • Quiet Operation: The blower wheel is mounted directly on the motor shaft to reduce the noise level. • Fresh Air Inlet: Manual or optional power-operated inlet allows fresh air to enter through the rear of the heater and mix with re-circulated room air. Applications •Classrooms •Stairways •Hallways •Corridors • Meeting Rooms • Waiting Rooms •Lobbies • Entry Ways Standard Construction Features Heating Elements – Industrial grade steel finned tubular elements. Housing – Cabinet is constructed of 18-gauge steel with an polyester powder paint finish in white or almond. Outlet Grille – An extruded architectural style aluminum grille discourages tampering with the heating element. The grille can be field converted for front or top air discharge. Built-in Controls – Automatic reset thermal cutout and fan delay. Power fusing is supplied for heaters over 48 amps. 56 Fan Motor – The squirrel cage fan is beltless and two-speed, operating at 48 dBA at low speed and 50 dBA at high speed. Fan motors have permanently lubricated sleeve bearings for trouble-free service. Installation Requirements – For best performance, do not install cabinet heaters above recommended maximum mounting height of ten feet. Rough In Dimensions – Recess mounting only: Heater Length + 1” wide x 27” high x 12 deep. 922 Series Factory Built-in Options Code Field-Installed Options (shipped loose for field installation into heater) Description A1 Fresh Air Inlet (1) A2 Power Operated Fresh Air Inlet (1) D1 Disconnect Switch 600V, Three-pole, 40 Amp D2 Disconnect Switch 600V, Three-pole, 80 Amp 922-124530 G Fusing 922-124531 M Manual Reset 922-124532 N1 2-Speed Motor w/High-Low Switch (2) 922-124533 80 (2032) N2 2-Speed Motor w/High-Low Relay-24 (1) (2) (3) 922-124534 28 (711) R1 24V Relay 922-124535 R2 24V Relay with Transformer 922-124536 Catalog Number 28 (711) 922-124537 Smooth Finish on Heater Back 48 (1219) 922-124538P Heater Length - In. (mm) 66 (1677) 922-124539P 80 (2032) 922-124540P S1 On/Auto Fan Relay-24V 922-124541P S2 24V On/Standby Heating Relay with Transformer 922-124538 S3 On/Auto Fan Switch 922-124539 S4 On/Standby Heating Switch 922-124540 T1 Tamperproof Thermostat, 1-Stage, Single-pole 922-124541 Tamperproof Thermostat, 2-Stage (4) 922-218265 T7 922-218266 (1) Do not install built-in thermostat with these options. 922-218267 (2) To obtain the minimum ratings, it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” two-speed motor with high/low relay-24 Volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field-furnished low voltage device for maximum/minimum control. 922-218268 Top 922-224750 Air Discharge 48 (1219) Sub Base 66 (1676) 48 (1219) Recess Trim Kit 66 (1676) 80 (2032) 28 (711) Permanent/Washable 48 (1219) Air Filters 66 (1676) (Wall Installation Only) 80 (2032) 28 (711) Replaceable Throwaway 48 (1219) Air Filters 66 (1676) (Wall Installation Only) 80 (2032) Smooth Finish on Heater Back Kit 28 (711) 48 (1219) 66 (1676) Heater Length In (mm) 80 (2032) Tamperproof single-pole thermostat kit Special or custom colors - See inside back cover for color codes to be B1 C1 added to end of A1 part number. Remote Room Thermostat – See page 99 D1 Bottom Air Discharge Mounting Applications A2 B2 C2 D2 A3 B3 C3 D3 Ceiling Top Air Discharge B1 C1 D1 Ceiling Bottom Air Discharge A2 B2 C2 D2 A3 B3 C3 D3 Ceiling Ceiling 28 (711) Standard colors - Add W for white finish or A for almond finish to the end of part number. (3) Option N2 is required for two-stage remote thermostat operation. (4) When choosing Option T7; A1, A2, N1, N2, R1, R2 & T1 are unavailable. A1 Heater Length In. (mm) Description H E A T E R S S F O R C E D - A I R Cabinet Unit Heater Wall Semi-recessed Recessed D3 type mounting only Wall Recessed Semi-recessed D1 or D2 type mounting only 57 922 Series H E A T E R S Cabinet Unit Heater K.O.1-3/4 -1-3/8" WWall allOpening penin O g F O R C E D - A I R 27" K.O.1-1/ 8 -7/8" 26" Front View FrontVie w 2-1/1 6" Length + 1" Bottom View Bottom View Max. Min. 2000 1333 3000 1000 4000 2667 5000 3333 6000 4000 208 208 240 240 277 480 208 208 240 240 277 480 208 208 240 240 277 480 208 208 240 240 277 480 208 208 240 240 277 480 K.O.1/4" Surface Installation 2” 10” 2-1/2" Maximum recommended installation height: 10 feet. 7-3/8" Total Amps (2) CFM Max. Min. Max. Min 11.0 7.0 9.7 6.2 8.6 3.8 15.8 9.7 13.9 8.6 12.2 5.0 20.6 12.5 18.1 11.0 15.8 6.2 25.4 15.3 22.2 13.4 19.4 7.4 30.2 18.1 26.4 15.8 23.1 8.6 7.8 5.1 7.0 2.6 6.2 3.0 6.2 4.2 5.6 3.8 5.0 2.6 14.2 8.8 12.5 7.8 11.0 4.6 17.4 10.7 15.3 9.5 13.4 5.4 20.6 12.5 18.1 11.0 15.8 6.2 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 Semi-Recessed 2" Heater Listing Volts Phase Recessed 1-1/2" 3-5/16" 6-3/16" Watts (1) Installation With Recess Trim Kit Installation 2" With A Sub Base Approximate Air Heater Length Temp. Rise °F (°C) In. (mm) 26 (14) 26 (14) 26 (14) 26 (14) 26 (14) 26 (14) 38 (21) 38 (21) 38 (21) 38 (21) 38 (21) 38 (21) 51 (28) 51 (28) 51 (28) 51 (28) 51 (28) 51 (28) 64 (36) 64 (36) 64.(36) 64 (36) 64 (36) 64 (36) 77 (43) 77 (43) 77 (43) 77 (43) 77 (43) 77 (43) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) Weight Lbs (kg) Catalog Number 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) 115 (52) HX-922U02000C HX-922U02000D HX-922U02000J HX-922U02000K HX-922U02000N HX-922U02000U HX-922U03000C HX-922U03000D HX-922U03000J HX-922U03000K HX-922U03000N HX-922U03000U HX-922U04000C HX-922U04000D HX-922U04000J HX-922U04000K HX-922U04000N HX-922U04000U HX-922U05000C HX-922U05000D HX-922U05000J HX-922U05000K HX-922U05000N HX-922U05000U HX-922U06000C HX-922U06000D HX-922U06000J HX-922U06000J HX-922U06000N HX-922U06000U (1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” twospeed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device for maximum/minimum control. (2) Total Amps = Heating element amps and motor amps. Other voltages available. Consult factory. Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Specify mounting application code when ordering (see page 57). 58 922 Series Heater Listing (continued) Watts (1) Max. Min. Volts Phase 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 3 1 3 1 3 3 1 3 1 3 3 3 1 3 3 CFM Max. Min. Max. Min 41.3 25.0 36.1 22.1 31.7 12.4 50.9 30.6 44.5 26.9 38.9 14.8 60.5 36.1 52.8 31.7 46.1 17.3 76.3 45.9 66.7 40.3 22.3 90.7 54.2 79.2 47.5 25.9 101.8 61.1 88.9 53.7 29.7 72.2 105.6 63.3 34.5 22.0 13.9 19.5 12.4 17.2 7.6 26.8 16.7 23.6 14.8 20.9 8.8 31.6 19.5 27.8 17.3 24.8 10.0 52.3 32.0 45.9 28.3 16.2 61.9 37.5 54.2 33.1 18.6 69.7 42.6 61.2 37.7 21.7 50.1 72.3 44.1 24.9 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 750 750 750 750 750 750 750 750 750 750 1000 1000 1000 1000 1000 1000 1000 1000 1000 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 600 600 600 600 600 600 600 600 600 600 800 800 800 800 800 800 800 800 800 Approximate Air Heater Length Temp. Rise °F (°C) In. (mm) 51 (28) 51 (28) 51 (28) 51 (28) 51 (28) 51 (28) 64 (36) 64 (36) 64 (36) 64 (36) 64 (36) 64 (36) 77 (43) 77 (43) 77 (43) 77 (43) 77 (43) 77 (43) 63 (35) 63 (35) 63 (35) 63 (35) 63 (35) 77 (43) 77 (43) 77 (43) 77 (43) 77 (43) 64 (36) 64 (36) 64 (36) 64 (36) 64 (36) 77 (43) 77 (43) 77 (43) 77 (43) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 66 (1677) 80 (2032) 80 (2032) 80 (2032) 80 (2032) 80 (2032) 80 (2032) 80 (2032) 80 (2032) 80 (2032) Weight Lbs (kg) Catalog Number 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 146 (66) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 210 (96) 240 (109) 240 (109) 240 (109) 240 (109) 240 (109) 240 (109) 240 (109) 240 (109) 240 (109) HX-922U08000C HX-922U08000D HX-922U08000J HX-922U08000K HX-922U08000N HX-922U08000U HX-922U10000C HX-922U10000D HX-922U10000J HX-922U10000K HX-922U10000N HX-922U10000U HX-922U12000C HX-922U12000D HX-922U12000J HX-922U12000K HX-922U12000N HX-922U12000U HX-922U15000C HX-922U15000D HX-922U15000J HX-922U15000K HX-922U15000U HX-922U18000C HX-922U18000D HX-922U18000J HX-922U18000K HX-922U18000U HX-922U20000C HX-922U20000D HX-922U20000J HX-922U20000K HX-922U20000U HX-922U24000D HX-922U24000J HX-922U24000K HX-922U24000U H E A T E R S 208 208 240 8000 4000 240 277 480 208 208 240 10000 5000 240 277 480 208 208 240 12000 6000 240 277 480 208 208 15000 10000 240 240 480 208 208 18000 12000 240 240 480 208 208 20000 13333 240 240 480 208 240 24000 16000 240 480 Total Amps (2) F O R C E D - A I R Cabinet Unit Heater (1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” twospeed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device for maximum/ minimum control. (2) Total Amps = Heating element amps and motor amps. Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Specify mounting application code when ordering (see page 57). 59 936/937 Series F O R C E D - A I R H E A T E R S Fan-Forced Ceiling Heater 936 Series Surface Mounting 937 Series Recessed Mounting Applications Downward Discharge Uniform Circulation The 936/937 ceiling heaters are designed for commercial applications. 936 Series heaters are designed for surface mounting and most can be adapted for T-Bar installation with an optional kit. The 937 Series heater is designed for recessed mounting and installation into 2-feet by 2-feet ceiling grids. The 937 Series comes with a built-in flange; an additional trim ring kit is not required. • Enhanced Performance: These heaters set new industry standards with ratings up to 10,000 W and 700 CFM in single and three-phase 208, 240 and 480 voltages. • Increased Comfort: The side draw-through inlet with down discharge promotes circulation within the space for uniform temperatures and increased comfort. • Classrooms • Offices • Day Care • Reception Areas • Entryways • Restrooms • Guard Houses • Vestibules • Hallways • Workshops • Lobbies Standard Construction Features Heating Elements – Stainless steel tubular elements with aluminum fins. Outlet Grille – The grille is made of 20-gauge galvanized steel and is finished with a polyester powder paint in white or almond. Built-in Controls – Automatic reset thermal cutout and fan delay relay. Fan Motor – Quiet, direct drive aluminum fan and totally enclosed motor with lifetime lubricated ball bearings. Installation Requirements – For best performance, ceiling heaters should be installed between 8 and 12-feet above the floor. Rough In Dimensions – 937 Series Only: 23” wide x 23” high x 6” deep. Factory Built-in Options Code 60 Description D1 Disconnect Switch 600V, Three-pole, 40 Amp D2 Disconnect Switch 600V, Three-pole, 80 Amp D3 Disconnect Switch 277V, Double-pole, 20 Amp R1 24V Control Relay R2 24V Control Relay with Transformer S3 Summer Fan Switch and Pilot Light S5 Summer Fan 24V Relay for Remote Switching and Pilot Light (Switch not included) S6 Summer Fan 240V Relay for Remote Switching and Pilot Light (Switch not included) T1 Tamperproof Thermostat X 120V Control, fused secondary and grounded Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description 936-158478 Tamperproof Thermostat Kit 936-158479 T-Bar Adaptor for CDI surface mounting 2000 through 5000 watt heaters only 936-218269 24V Control Relay Kit Add W to end of catalog number for white finish or add A for almond finish. Remote Room Thermostat – See page 99 936/937 Series K.O. 1-1/8 7/8" K.O. 1/4" 2-3/4" 1-7/8" 2-1/2" 1-9/16" K.O. 1-1/8/ 7/8" K.O.1/4 5-11/16" 5" 5-5/8" 4-3/4" 22-5/8" 1-3/16" 2-1/1 6-1/2" 16-3/8" 936 Series 2,000-5,000 Watt Surface Mounting 1-7/8 1-9/16" 6-1/2" 7-15/16" 6-1/2" 7-15/16" 23-7/8" 22-5/16" 23-7/8" 16-3/8" 937 Series 2,000-5,000 Watt Recessed Mounting K.O.1/4 2-3/4" 2-1/2" H E A T E R S 7-5/16" K.O. 1-1/8/ 7/8 F O R C E D - A I R Fan-Forced Ceiling Heater 22-5/16" 936 Series 7,500-10,000 Watt Surface Mounting 1 Hanger Clips 936 Series Surface Mounting for 7,500 to 10,000 Watt Heaters 2 937 Series Recessed Mounting 936 Series Surface Mounting for 2,000 to 5,000 Watt Heaters 61 936/937 Series H E A T E R S Fan-Forced Ceiling Heater Surface Mounting Heater Listing F O R C E D - A I R Watts 2000 3000 4000 5000 7500 9900 10000 Volts Phase Total Amps (1) CFM Approximate Air Temperature Rise °F (°C) Weight lb (kg) Catalog Number 208 208 240 240 277 480 480 208 208 240 240 277 480 480 208 208 240 240 277 480 480 208 208 240 240 277 480 480 1 3 1 3 1 1 3 1 3 1 3 1 1 3 1 3 1 3 1 1 3 1 3 1 3 1 1 3 10.3 6.3 9.0 5.5 7.9 4.9 3.1 15.1 9.0 13.2 7.9 11.5 7.0 4.3 19.9 11.8 17.4 10.3 15.1 9.0 5.5 24.7 14.6 21.5 12.7 18.8 11.1 6.7 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 14 (8) 21 (12) 21 (12) 21 (12) 21 (12) 21 (12) 21 (12) 21 (12) 28 (16) 28 (16) 28 (16) 28 (16) 28 (16) 28 (16) 28 (16) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 35 (19) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) 25 (11.3) HX-936U02000C¶ HX-936U02000D¶ HX-936U02000J¶ HX-936U02000K¶ HX-936U02000N¶ HX-936U02000T¶ HX-936U02000U¶ HX-936U03000C¶ HX-936U03000D¶ HX-936U03000J¶ HX-936U03000K¶ HX-936U03000N¶ HX-936U03000T¶ HX-936U03000U¶ HX-936U04000C¶ HX-936U04000D¶ HX-936U04000J¶ HX-936U04000K¶ HX-936U04000N¶ HX-936U04000T¶ HX-936U04000U¶ HX-936U05000C¶ HX-936U05000D¶ HX-936U05000J¶ HX-936U05000K¶ HX-936U05000N¶ HX-936U05000T¶ HX-936U05000U¶ 208 1 36.8 700 34 (19) 34 (15.4) HX-936U07500C¶ 208 240 240 277 480 480 208 208 240 240 277 480 480 3 1 3 1 1 3 1 3 1 3 1 1 3 21.5 32.0 18.7 27.8 16.3 9.7 48.0 28.0 42.4 24.8 36.8 21.5 12.7 700 700 700 700 700 700 700 700 700 700 700 700 700 34 (19) 34 (19) 34 (19) 34 (19) 34 (19) 34 (19) 46 (26) 46 (26) 46 (26) 46 (26) 46 (26) 46 (26) 46 (26) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) 34 (15.4) HX-936U07500D¶ HX-936U07500J¶ HX-936U07500K¶ HX-936U07500N¶ HX-936U07500T¶ HX-936U07500U¶ HX-936U09900C¶ HX-936U09900D¶ HX-936U10000J¶ HX-936U10000K¶ HX-936U10000N¶ HX-936U10000T¶ HX-936U10000U¶ (1) Total Amps = Heating element amps and motor amps. ¶Add W to end of catalog number for white finish or add A for almond finish. Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number. 62 936/937 Series Recessed Mounting Heater Listing Watts 3000 4000 5000 Phase Total Amps (1) CFM Approximate Air Temperature Rise °F (°C) Weight lb (kg) Catalog Number 208 1 10.3 450 14 (8) 31 (14) HX-937U02000C¶ 208 3 6.3 450 14 (8) 31 (14) HX-937U02000D¶ 240 1 9.0 450 14 (8) 31 (14) HX-937U02000J¶ 240 3 5.5 450 14 (8) 31 (14) HX-937U02000K¶ 277 1 7.9 450 14 (8) 31 (14) HX-937U02000N¶ 480 1 4.9 450 14 (8) 31 (14) HX-937U02000T¶ 480 3 3.1 450 14 (8) 31 (14) HX-937U02000U¶ 208 1 15.1 450 21 (12) 31 (14) HX-937U03000C¶ 208 3 9.0 450 21 (12) 31 (14) HX-937U03000D¶ 240 1 13.2 450 21 (12) 31 (14) HX-937U03000J¶ 240 3 7.9 450 21 (12) 31 (14) HX-937U03000K¶ 277 1 11.5 450 21 (12) 31 (14) HX-937U03000N¶ 480 1 7.0 450 21 (12) 31 (14) HX-937U03000T¶ 480 3 4.3 450 21 (12) 31 (14) HX-937U03000U¶ 208 1 19.9 450 28 (16) 31 (14) HX-937U04000C¶ 208 3 11.8 450 28 (16) 31 (14) HX-937U04000D¶ 240 1 17.4 450 28 (16) 31 (14) HX-937U04000J¶ 240 3 10.3 450 28 (16) 31 (14) HX-937U04000K¶ 277 1 15.1 450 28 (16) 31 (14) HX-937U04000N¶ 480 1 9.0 450 28 (16) 31 (14) HX-937U04000T¶ 480 3 5.5 450 28 (16) 31 (14) HX-937U04000U¶ 208 1 24.7 450 35 (19) 31 (14) HX-937U05000C¶ 208 3 14.6 450 35 (19) 31 (14) HX-937U05000D¶ 240 1 21.5 450 35 (19) 31 (14) HX-937U05000J¶ 240 3 12.7 450 35 (19) 31 (14) HX-937U05000K¶ 277 1 18.8 450 35 (19) 31 (14) HX-937U05000N¶ 480 1 11.1 450 35 (19) 31 (14) HX-937U05000T¶ 480 3 6.7 450 35 (19) 31 (14) HX-937U05000U¶ H E A T E R S 2000 Volts F O R C E D - A I R Fan-Forced Ceiling Heater (1) Total Amps = Heating element amps and motor amps. ¶Add W to end of catalog number for white finish or add A for almond finish. Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number. 63 931 Series F O R C E D - A I R H E A T E R S Commercial Ceiling Heater Applications •Entryways •Restrooms •Garages •Stairwells •Hallways •Vestibules The 931 Series ceiling heater is designed for commercial use in areas where no wall space is available. It provides supplemental heat to prevent cold drafts or wide temperature swings. • E xtended Capacity: Heaters are available as single or double modules with ratings up to 8,000 W and 320 CFM in 480 volt single-phase. • C ontrol Options: Heaters can be controlled by a building management system with the addition of a low voltage relay. • F lexible Mounting: Units can be surface, (with optional surface mounting box) recessed or installed in T-Bar ceiling systems. Standard Construction Features Heating Elements – Steel finned tubular elements. Fan Motor – Permanently lubricated, open and ventilated fan. Outlet Grille – The louvered front grille is made of 18-gauge steel with rounded corners. The grille is finished with a polyester powder paint in white or almond. Installation Requirements – For best performance, do not install ceiling heaters above recommended maximum mounting height of ten feet. Heater must be installed at least ten inches from adjacent walls. Built-in Controls – Automatic reset thermal cutout, fan override and 240 volt standard control, with contactor when required. Rough In Dimensions – • 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high x 4-1/2” deep. • 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high x 4-1/2” deep. Factory Built-in Options Code Description D1 Disconnect Switch 600V, Three-pole, 40 Amp D3 Disconnect Switch 277V, Double-pole, 20 Amp R1 24V Control Relay R2 24V Control Relay with Transformer T1 Built-in Tamperproof Thermostat T2 Adjustable Thermostat Remote Room Thermostat – See page 99 Standard colors - Add W for white finish or A for almond finish to the end of catalog number. 64 Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Field-Installed Options (shipped loose for field installation into heater) Catalog Number 931-124506 931-158213 931-124507 931-124508 931-124509 931-124510 931-124511 931-124512 931-124513 931-218272 931-218273 Description Surface Mounting Box (1500-4800W) Surface Mounting Box (6000-8000W) Thermostat Kit 24V Control Relay Kit 24V Control Relay with Transformer, 208V Kit 24V Control Relay with Transformer, 240V Kit 24V Control Relay with Transformer, 277V Kit T-Bar Adapter 23-3/4” x 23-3/4” (1500-4000W) T-Bar Adapter 23-3/4” x 23-3/4” (6000-8000W) Extruded Aluminum Front Grille (1500-4000W) Extruded Aluminum Front Grille (6000-8000W) Mounting Box for Aluminum Front Grille 931-218274 Surface (1500-4800W) Mounting Box for Aluminum Front Grille 931-218275 Surface (6000-8000W) 931 Series Heater Listing Watts 1500/1125 1500 2000 3000/2250 3000 4000/3000 4000 6000/4500 6000 8000/6000 8000 Total Amps (1) CFM 240/208 277 480 240/208 277 480 240/208 277 480 240/208 208 277 480 240/208 277 480 240/208 208 277 480 6.6/5.8 5.8 3.5 8.7/7.6 7.6 4.5 12.9/11.2 11.2 6.6 17.0/14.8 19.6 14.8 8.7 25.4/22.0 22.1 12.9 33.7/29.2 38.9 29.3 17.1 160 160 160 160 160 160 160 160 160 160 160 160 160 320 320 320 320 320 320 320 Approximate Air Temperature Rise °F (°C) 30/27 (17/12) 30 (17) 30 (17) 40/30 (22/17) 40 (22) 40 (22) 60/45 (33/25) 60 (33) 60 (33) 80/60 (44/33) 80 (44) 80 (44) 80 (44) 60/45 (33/25) 60 (33) 60 (33) 80/60 (44/33) 80 (44) 80 (44) 80 (44) Weight lb (kg) Catalog Number 20 (9) 26 (12) 26 (12) 20 (9) 26 (12) 26 (12) 20 (9) 26 (12) 26 (12) 20 (9) 20 (9) 26 (12) 26 (12) 40 (18) 52 (24) 52 (24) 40 (18) 40 (18) 52 (24) 52 (24) HX-931U01500V HX-931U01500N HX-931U01500T HX-931U02000V HX-931U02000N HX-931U02000T HX-931U03000V HX-931U03000N HX-931U03000T HX-931U04000V HX-931U04000C HX-931U04000N HX-931U04000T HX-931U06000V HX-931U06000N HX-931U06000T HX-931U08000V HX-931U08000C HX-931U08000N HX-931U08000T H E A T E R S 2000/1500 Volts (1 Phase) F O R C E D - A I R Commercial Ceiling Heater (1) Total Amps includes motor amps. Standard colors - Add W for white finish or A for almond finish to the end of catalog number. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 6,000 - 8,000 Watts 1,500 - 4,000 Watts - - " - " " - - Required wall depth opening 109 mm 4 5/16" - - 109 mm 4 5/16" " 561 mm 22 1/16" - Side view All models - - " - " " - - " " " - " " " " 65 938 Series H E A T E R S Fan-Forced Toe-Space Heater The 938 Series heater is designed for installation in places where other heaters do not fit. These heaters can be installed into the toe space or kick space below a cabinet, in the soffit above a cabinet or into risers of a stairway. F O R C E D - A I R • Multiple Wattage: Quick disconnect lead wires allow output conversion from 1,000 to 500 watts. • Overtemperature Protection: Automatic reset thermal cutout is provided for primary overtemperature protection. More convenient than thermal fuses, which require field replacement when overtemperature conditions occur. Applications • Checkout Counters • Reception Areas •Kitchens •Ticket/Tollbooths • T wo-piece Construction: Unit is designed for easy installation. The fan, motor and controls are factory assembled into a sheet metal box with a removable front grille. Standard Construction Features Heating Elements – Steel finned tubular elements provide durability. Fan Motor – Factory-lubricated fan motor operates at 44.5 dBA with 80 CFM. Outlet Grille – Heavy 20-gauge steel grille has a polyester powder paint finish. Standard grille colors include black, white or almond. Soffit Adapter – Included with the heater. Built-in Controls – Heater comes complete with a bi-metal automatic reset thermal cutout and warning light to indicate when the heater is running excessively hot. Rough In Dimensions – All heaters: 20-1/2” wide x 3-27/32” high x 10-1/2” deep. Factory Built-in Options Code Adjustable thermostat, single-pole T6 Adjustable thermostat, double-pole Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description T5 Installation Requirements – Do not install heater on or above vinyl flooring. Description 938-158480 Adjustable thermostat kit, single-pole 938-218240 Adjustable thermostat kit, double-pole 20-1/4" 4" MAX 3 27/32" Floor Wall Opening 10 1/2" 20 1/2" 4" 3-11/16" 21-3/4" 10- 1/8" Heater Listing Watts Volts 1000/500 500/375 1000/750 120 240/208 Total Amps (1) CFM 8.8/4.6 2.5/2.3 4.6/4.1 80 80 80 Approximate Air Temperature Rise °F (°C) 20 (11) 20/15 (11/8) 40/30 (22/17) (1) Total Amps = Heating element amps and motor amps. Add W to end of catalog number for white finish, A for almond, or BK for black. 66 Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Weight lb (kg) Catalog Number 13 (6) 13 (6) 13 (6) HX-938U01000B HX-938U01000V 939 Series F O R C E D - A I R Fan-Forced Floor Heater H E A T E R S The 939 Series floor heater is compact to fit into tight spaces. It is designed to mount between the floor joists. • U nique Design: The heater features a separate housing and core assembly. The core assembly is completely prewired with leads and an electrical connection plug, which can be removed for service and cleaning without disturbing the housing or field wiring. • Safety Screen: A protective screen prevents foreign objects from falling onto the heating elements or interfering with the fan. Applications •Entryways • Small Rooms • Open Stairwells • Under Large Window Areas Standard Construction Features Heating Elements – Steel finned tubular elements provide durability. Fan Motor – Quiet, factory-lubricated fan motor operates at 39.5 dBA with 80 CFM. Housing – Heavy welded 20-gauge steel housing. Installation Requirements – Floor heaters should be installed a minimum of six inches from adjacent walls. Outlet Grille – The 14-gauge steel grille has a polyester powder paint finish. Standard grille colors include bronze, white or almond. Built-in Controls – Manual reset thermal cutout prevents overheating. Rough In Dimensions – All heaters: 14-3/8” wide x 7-7/16” high x 8” deep. Heater Listing Watts Volts Total Amps (1) CFM Approximate Air Temperature Rise °F (°C) Weight lb (kg) Catalog Number 500 120 4.6 80 20 (11) 16 (7.3) HX-939U00500B 1000 120 8.8 80 40 (22) 16 (7.3) HX-939U01000B 1500 120 13.0 80 60 (33) 16 (7.3) HX-939U01500B 100/750 240/208 4.6/4.1 80 40/30 (22/17) 16 (7.3) HX-939U01000V 1500/1125 240/208 6.7/5.9 80 60/45 (33/25) 16 (7.3) HX-939U01500V (1) Total Amps = Heating element amps and motor amps. Add W to end of catalog number for white finish, A for almond, or BZ for bronze. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Remote Room Thermostat – See page 99 8" 14-1/4" 7-1/4" 67 COMPARISON CHART Baseboard and Convector Heaters 907 H E A T E R S 914 903 B A R R I E R 906 D R A F T A N D C O N V E C T O R B A S E B O A R D 68 911 916 908 Architectural Industrial Architectural Architectural Sill-Height Sill-Height Cabinet Convector Convector Convector Convector 908/909Series 904/906Series 905/907Series 911/912Series Mini Draft Barrier 914 Series High Watt Density Draft Barrier 916 Series Features Baseboard 903 Series Typical Applications Retail stores, Small offices Commercial buildings, Public buildings Industrial buildings, Institutions Wattage Range 300 to 2,500 200 to 2,500 200 to 2,500 800 to 4,000 1,000 to 6,000 300 to 1,400 375 to 4,000 Watt Density W/ft (W/m) 275 (900) 200 (650) 275 (900) 200 (650) 150 (490) 100 (330) 275 (900) 200 (650) 150 (490) 100 (330) 500 (1640) 375 (1250) 1,000 (3,280) 750 (2,450) 500 (1,640) 175 (574) 150 (490) 500 (1,640) 355 (1,165) 250 (820) 175 (575) Voltages 120 - 277 (1 Ph) 120 - 277 (1 Ph) 120 - 277 (1 Ph) 208 - 277 (1 Ph) 208 - 277 (1 Ph) 208 - 480 (3 Ph) 208 - 480 (1 Ph) 208 - 480 (1 Ph) Banks, Offices Classrooms, Entryways, Classrooms, Entryways, HallConference Hallways, Conference ways, Schools rooms, Hallways Shoppingcenters rooms Element Type Stainless Stainless Stainless Stainless Stainless Stainless Stainless steel with steel with steel with steel with steel with steel with steel with aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins aluminum fins Standard Construction 20-gaugesteel 18-gauge 18-gauge 20-gaugesteel 18-gaugesteel cabinetry, steelcabinetry 22-gaugesteel steelcabinetry cabinetry with 16-gaugesteel cabinetry with with14-gauge bodyandfront with14-gauge 16-gaugesteel frontcoverand 16-gaugesteel aluminumfront aluminumfront panel front cover extruded front cover and top covers cover aluminumgrille 18-gauge steelcabinetry with14-gauge aluminumfront and top covers Finish Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Polyester powder paint Sloped-Top Version No 904 Series 905 Series 908 Series 911 Series No No Bottom Air Inlet Option No Yes Yes No No Standard Standard Pedestal Kit Option No Yes Yes Yes Yes Yes Yes Front Warm Air Outlet Option No No No No No Custom Colors Yes Yes Agency Approvals CSAUS CSAUS Yes Yes (909 Series only) (912SeriesOnly) Yes Yes Yes Yes Yes CSAUS CSAUS CSAUS CSAUS CSAUS 903 Series •Offices •Restrooms •Retail Stores •Restaurants H E A T E R S Applications The 903 Series baseboard heater is more compact than any other heater on the market, yet it provides a high level of performance and strength. The unit’s trim design enhances its appearance and rounded corners eliminate the sharp edges found on square heaters. • E asy to Install: Heaters may be mounted flush on any floor surface. Two rows of oblong mounting holes with center mark for ease of installation. No disassembly installation with single-screw built-in rear entry wire holder. • E lectric Receptacles: Units can be furnished with built-on 120 and 240-volt receptacles to provide access for other electrical appliances. • C ontrol Options: Heaters can be controlled by a building management system with the addition of a low voltage relay. Adding a proportional control device provides precise temperature control and increased energy savings. B A S E B O A R D Baseboard Heater Standard Construction Features Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation. Built-in Controls – Linear limit, automatic reset thermal cutout. Housing – Robust 22-gauge steel body with 20-gauge front panel and welded junction box, with 4H pencil hardness epoxy/polyester powder paint finish in white or almond. 69 903 Series Baseboard Heater Field-Installed Options H E A T E R S Factory Built-in Options B A S E B O A R D Code (shipped loose for field installation into heater) Description D3 Disconnect Switch, 277V, Double-pole, 20 Amp M1 High Altitude Automatic Cutout R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R7 Triac Proportional Relay, 277V Max, 2500 W Max T1 Tamperproof Thermostat, Single-pole, 277V, 25 Amp T2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp with off position T5 Adjustable Thermostat, Single-pole, 277V, 25 Amp T6 Adjustable Thermostat, Double-pole, 277V, 25 Amp with off position 62 mm 2-7/16" 64.5 mm 2-9/16" KOE �22M KOE �7/8" 148 mm 5-13/16" 34 mm 1-3/8" 75 mm 2-15/16" Side View Catalog Number Description 903-243496‡ Baseboard Section 6 in. (152 mm) - 240V Splitter Box to permanently connect an air conditioner (20A switch, double-pole, double-throw) 903-243497‡ Baseboard Section 6” (152mm) - 240V Splitter Box toward a surface mount, 6-20R Receptacle, 20A switch, double-pole, double throw 903-243498‡ Baseboard Section 6” (152mm) - Surface mounted duplex 5-15R receptable, 120V, 15A 903-243499‡ Baseboard Section 6” (152mm) - Surface mounted duplex 6-20R receptable, 240V 903-243500‡ Baseboard Section 6” (152mm) - for the installation of a 24V relay (relay not included) 903-243501 Electronic Relay Kit, single-pole, coil 24V, with transformer, 15A 277 max 903-243502 Electronic Relay Kit, single-pole, coil 24V, without transformer, 15A 277 max 903-243503 Relay Kit 24V with transformer, 120V, 25 Amp (2-wire only) 903-243504 Relay Kit 24V with Transformer, 208V, 22 Amp 903-243505 Relay Kit 24V with Transformer, 240V, 22 Amp 903-243506 Relay Kit 24V with Transformer, 277V, 19 Amp 903-243507 Relay Kit 24V without Transformer, 120V - 240V, 22 Amp, 277V, 19 Amps 903-243509‡ Thermostat Kit, Adjustable, Double-pole, 277V, 25 Amp with off position 903-243510‡ Thermostat Kit, Adjustable, Single-pole, 277V, 25 Amp 903-243511‡ Thermostat Kit, Tamperproof, Double-pole, 277V, 25 Amp with off position 903-243512‡ Thermostat Kit, Tamperproof, Single-pole, 277V, 25 Amp 903-243513‡ Touch Up Brush Paint (1/2 oz) 903-243514‡ Touch Up Spray Paint (6 oz) 903-243515‡ Universal Corners (inside and outside) Standard colors - Add W for white finish or A for almond finish to the end of part number. Special or custom colors - See inside back cover for color codes to be added to end of part number. 70 903 Series Heater Listing How to order: Heater Code with color code + Options (example HX-903U00750BW-T1) Standard Watt Density Models 275 W/ft. (900 W/m) Heater Code Dual Voltage Heater Code Watts 120V (1 Ph) Amps 208V (1 Ph) Amps 277V (1 Ph) Amps Watts at 240/208V 22.75 (577) 300 HX-903U00300B‡ 2.5 HX-903U00300C‡ 1.4 — 1.1 300/225 HX-903U00300V‡ 1.3/1.1 4.5 (2.0) 27.75 (702) 500 HX-903U00500B‡ 4.2 HX-903U00500C‡ 2.4 HX-903U00500N‡ 1.8 500/375 HX-903U00500V‡ 2.1/1.8 5.5 (2.5) 37.75 (956) 750 HX-903U00750B‡ 6.3 HX-903U00750C‡ 3.6 HX-903U00750N‡ 2.7 750/563 HX-903U00750V‡ 3.1/2.7 7.3 (3.3) 48 (1217) 1000 HX-903U01000B‡ 8.3 HX-903U01000C‡ 4.8 HX-903U01000N‡ 3.6 1000/750 HX-903U01000V‡ 4.2/3.6 9.0 (4.0) 60 (1524) 1250 HX-903U01250B‡ 10.4 HX-903U01250C‡ 6.0 HX-903U01250N‡ 4.5 1250/938 HX-903U01250V‡ 5.2/4.5 10.5 (4.8) 72 (1829) 1500 HX-903U01500B‡ 12.5 HX-903U01500C‡ 7.2 HX-903U01500N‡ 5.4 1500/1125 HX-903U01500V‡ 6.3/5.4 12.0 (5.5) 75.5 (1916) 1750 — — HX-903U01750C‡ 8.4 HX-903U01750N‡ 6.3 1750/1313 HX-903U01750V‡ 7.3/6.3 13.5 (6.2) 96 (2439) 2000 — — HX-903U02000C‡ 9.6 HX-903U02000N‡ 7.2 2000/1500 HX-903U02000V‡ 8.3/7.2 15.0 (6.8) 93 (2364) *2250 — — HX-903U02250C‡ 10.8 HX-903U02250N‡ 8.1 *2250/1688 HX-903U02250V‡ 9.4/8.1 16.5 (7.5) 102.25 (2596) *2500 — — HX-903U02500C‡ 12.0 HX-903U02500N‡ 9.0 *2500/1875 HX-903U02500V‡ 10.4/9.0 18.0 (8.2) 240/208V (1 Ph) Amps Weight Lbs (kg) H E A T E R S Length In. (mm) B A S E B O A R D Baseboard Heater Other single-phase voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to the catalog number where ‡ is indicated. (*) These items must be ordered in pairs to reduce shipping damage. 16.8 mm 11/16" 89.5 mm 3-1/2" KOE �22mm KOE �7/8" Bottom View KOE �6.2 mm KOE �1/4" 89.5 mm 3-1/2" 72.8 mm 2-7/8" 89.5 mm 3-1/2" 24.1 mm 1" 75 mm 2-15/16" 89.5 mm KOE � 22mm KOE � 7/8" 3-1/2" 25.4 mm 1" 25.1 mm 1" 71 904/906 Series C O N V E C T O R S Architectural Sill-Height Convector Architectural Sloped Top Sill-Height Convector 906 904 Applications • Air, Rail or Bus Terminals •Hallways •Auditoriums •Lobbies •Corridors •Offices •Entryways •Foyers The 904/906 Series architectural sill-height convector (also known as draft barriers) are designed to fit under large windows to prevent cold down drafts. These heaters can provide total or supplemental heating for a variety of applications. • Installation Options: Units may be mounted to the wall flush on the floor or on pedestals. Custom lengths, blank sections and inside or outside corners are available for wall-to-wall installations. Units can be ordered with smooth painted finish when the back of the heater is visible. • Added Safety: The sloped-top of the 904 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating. • Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes including anodized aluminum are available. Standard Construction Features Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation. Housing – Cabinet is constructed of 18-gauge steel with a 14-gauge aluminum front cover. The unit has a polyester powder paint finish in white or almond. End caps are provided on all units. Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. The outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof). 72 Built-in Controls – Linear limit, automatic reset thermal cutout. Electrical Connection – Each baseboard heater has a junction box located on both ends and a built-in full length wireway. Installation Requirements – Field or factory-installed low voltage relay and thermostat kits fit into the righthand junction box only. 904/906 Series Factory Built-in Options Code Field-Installed Options (shipped loose for field installation into heater) Description A Bottom Air Inlet D3 Disconnect Switch, 277V, Double-pole, 20 Amp Catalog Number Description Custom Length 906-124585(1) Inside Corner M1 High Altitude Automatic Cutout 906-124586(1) Outside Corner R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp 906-124587 Round Pedestal Kit, 3-5”, Qty=2 R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp 906-169806 Square Pedestal Kit, 2”, Qty=2 R6 Pneumatic Relay, 480V, 20 Amp R7 Triac Proportional Relay, 277V Max., 2500W Max. S L 906-124588(1) Splice Plate 2” Long 906-124589(1) Contour Splice Plate for Code A (Bottom Air Inlet) and/or Heater with Pedestals Smooth painted finish on heater back 906-124590 24V Relay Kit, 240V, 22 Amp; 277V, 25 Amp T1 TamperproofThermostat,Single-pole,240V,25Amp; 277V, 10 Amp 906-124591 24V Relay Kit with Transformer, 120V, 22 Amp 906-124592 24V Relay Kit with Transformer, 208V, 22 Amp T2 TamperproofThermostat,Double-pole,240V,25Amp; 277V, 10 Amp 906-124593 24V Relay Kit with Transformer, 240V, 22 Amp 24V Relay Kit with Transformer, 277V, 19 Amp T5 Adjustable Thermostat, Single-pole, 240V, 25 Amp; 277V, 10 Amp 906-124594 906B-XXX(1) Blank Section (specify length in inches-XXX) (1) Change 906 prefix to 904 for sloped top. AdjustableThermostat, Double-pole, 240V, 25 Amp; 277V, 10 Amp Standard colors - Add W for white finish or A for almond finish to the end of part number. T6 C O N V E C T O R S Architectural Sill-Height Convector Architectural Sloped Top Sill-Height Convector Special or custom colors - See inside back cover for color codes to be added to end of part number. Remote Room Thermostat – See page 99 2-1/2" 4" K.O. 1/4" 6-1/8" 3-7/8" 1-3/8" 1-7/8" 1-1/8" 2-3/8" Rear View 15/16" Side View K.O. 7/8" 1-1/8" 7/8" 906 Series Bottom View 2-3/8" 2-1/2" 4" K.O. 1/4" 7-1/2" 3-7/8" 1-3/8" 1-7/8" 15/16" 2-3/8" 1-1/8" Rear View Side View K.O. 7/8" 904 Series 1-1/8" 7/8" 2-3/8" Bottom View 73 904/906 Series C O N V E C T O R S Architectural Sill-Height Convector Architectural Sloped Top Sill-Height Convector HX-906U (Flat Top) HX-904U (Sloped Top) How to order: Model + Heater Code with color code + Options (example HX-906U01000BW-2632-T5) Density Length Watts In. (mm) W/Ft W/m 29 (738) 39 (992) 49.3 (1253) 58.8 (1494) 67.5 (1715) 76.9 (1952) 85.6 (2175) 94.5 (2400) 103.6 (2632) Heater Code 120V (1 Ph) Amps 208V (1 Ph) Amps 277V (1 Ph) Watts at Amps 240/208V Amps Weight Lbs (kg) BCI BCSI (Flat) (Sloped) 100 330 200 00200B‡-738 1.7 00200C‡-738 1.0 — — 200/150 00200V‡-738 0.8/0.7 150 490 300 00300B‡-738 2.5 00300C‡-738 1.4 00300N‡-738 1.1 300/225 00300V‡-738 1.3/1.1 200 650 400 00400B‡-738 3.3 00400C‡-738 1.9 00400N‡-738 1.4 8.0 400/300 00400V‡-738 1.7/1.4 (3.6) 275 900 500 00500B‡ 4.2 00500C‡ 2.4 00500N‡ 1.8 500/375 100 330 300 00300B‡-992 2.5 00300C‡-992 1.4 00300N‡-992 1.1 300/225 00300V‡-992 1.3/1.1 150 490 450 00450B‡-992 3.8 00450C‡-992 2.2 00450N‡-992 1.6 200 650 600 00600B‡-992 5.0 00600C‡-992 2.9 00600N‡-992 2.2 450/338 00450V‡-992 1.9/1.6 10.4 600/450 00600V‡-992 2.5/2.2 (4.7) 275 100 900 330 750 00750B‡ 400 00400B‡-1253 6.3 3.3 00750C‡ 00400C‡-1253 3.6 00750N‡ 2.7 1.9 00400N‡-1253 1.4 750/563 00750V‡ 3.1/2.7 400/300 00400V‡-1253 1.7/1.4 150 490 600 00600B‡-1253 5.0 00600C‡-1253 2.9 00600N‡-1253 2.2 200 650 800 00800B‡-1253 6.7 00800C‡-1253 3.8 00800N‡-1253 2.9 600/450 00600V‡-1253 2.5/2.2 12.8 800/600 00800V‡-1253 3.3/2.9 (5.8) 275 900 1000 4.8 1000/750 100 330 500 00500B‡-1494 150 490 750 00750B‡-1494 200 650 1000 01000B‡-1494 275 900 1250 10.4 01250C‡ 100 330 600 00600B‡-1715 5.0 00600C‡-1715 2.9 00600N‡-1715 2.2 600/450 00600V‡-1715 2.5/2.2 150 490 900 00900B‡-1715 7.5 00900C‡-1715 4.3 00900N‡-1715 3.2 200 650 1200 01200B‡-1715 10.0 01200C‡-1715 5.8 01200N‡-1715 4.3 900/675 00900V‡-1715 3.8/3.2 17.2 1200/900 01200V‡-1715 5.0/4.3 (7.8) 275 900 1500 12.5 01500C‡ 7.2 100 330 5.8 00700C‡-1952 3.4 00700N‡-1952 2.5 150 490 1050 01050B‡-1952 8.8 01050C‡-1952 5.0 01050N‡-1952 3.8 200 650 1400 01400B‡-1952 11.7 01400C‡-1952 275 100 150 900 1750 — 330 800 00800B‡-2175 490 1200 01200B‡-2175 — 01750C‡ 6.7 00800C‡-2175 10.0 01200C‡-2175 200 650 1600 — — 01000B‡ 01250B‡ 01500B‡ 700 00700B‡-1952 275 900 2000 100 330 150 490 1350 200 650 1800 275 900 2250 100 150 01000C‡ 00500C‡-1494 2.4 00500N‡-1494 1.8 500/375 00500V‡-1494 2.1/1.8 6.3 00750C‡-1494 3.6 00750N‡-1494 2.7 8.3 01000C‡-1494 4.8 01000N‡-1494 3.6 750/563 00750V‡-1494 3.1/2.7 15.1 1000/750 01000V‡-1494 4.2/3.6 (6.8) 6.0 1250/938 01600C‡-2175 01250N‡ 01500N‡ 3.6 4.5 5.4 1500/1125 01000V‡ 01250V‡ 01500V‡ 9.1 (4.1) 2.1/1.8 4.2 — 01000N‡ 00500V‡ 8.3 11.9 (5.4) 14.7 (6.6) 4.2/3.6 17.3 (7.9) 5.2/4.5 19.7 (9.0) 6.3/5.4 700/525 00700V‡-1952 2.9/2.5 1050/788 01050V‡-1952 4.3/3.8 19.4 6.7 01400N‡-1952 5.1 1400/1050 01400V‡-1952 5.8/5.0 (8.8) 22.3 (10.1) 8.4 01750N‡ 6.3 1750/1313 01750V‡ 7.3/6.3 3.8 00800N‡-2175 2.9 800/600 00800V‡-2175 3.3/2.9 5.8 01200N‡-2175 4.3 1200/900 01200V‡-2175 5.0/4.3 21.5 7.7 01600N‡-2175 5.8 1600/1200 01600V‡-2175 6.7/5.8 (9.7) 24.7 (11.2) — 02000C‡ 7.5 00900C‡-2400 4.3 00900N‡-2400 3.2 — — 01350C‡-2400 — — 01800C‡-2400 6.5 01350N‡-2400 4.9 1350/1013 01350V‡-2400 5.6/4.9 23.6 27.2 8.7 01800N‡-2400 6.5 1800/1350 01800V‡-2400 7.5/6.5 (10.7) (12.3) — — 02250C‡ 330 1000 01000B‡-2632 8.3 01000C‡-2632 4.8 01000N‡-2632 3.6 490 1500 — — 01500C‡-2632 7.2 01500N‡-2632 5.4 1500/1125 01500V‡-2632 6.3/5.4 200 650 2000 — — 02000C‡-2632 200 650 2250 — — 275 900 2500 — — 900 00900B‡-2400 9.6 10.8 02000N‡ 02250N‡ 7.2 2000/1500 02000V‡ 8.3/7.2 900/675 00900V‡-2400 3.8/3.2 8.1 2250/1688 02250V‡ 9.4/8.1 1000/750 01000V‡-2632 4.2/3.6 9.6 02000N‡-2632 7.2 2000/1500 02000V‡-2632 8.3/7.2 25.8 29.7 (11.7) (13.5) 02250C‡-2632 10.8 02250N‡-2632 8.1 2250/1688 02250V‡-2632 9.4/8.1 02500C‡ 12.0 02500N‡ 9.0 2500/1875 Other voltages available. Consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number. 74 Heater Code 240/208V (1 Ph) 02500V‡ 10.4/9.0 905/907 Series 907 905 Applications • Air, Rail or Bus Terminals •Hallways •Auditoriums •Lobbies •Corridors •Offices •Entryways •Foyers C O N V E C T O R S Industrial Sill-Height Convector Industrial Sloped Top Sill-Height Convector The 905/907 Series industrial sill-height convector (also known as draft barriers) are designed to fit under large windows to prevent cold down drafts. The heaters are ideal for heavy traffic areas with high heating requirements. • Installation Options: Units may be mounted to the wall flush on the floor or on pedestals. Custom lengths and blank sections and inside or outside corners are available for wall-to-wall installations. Units can be ordered with smooth painted finish when the back of the heater is visible. • Length Options: Heaters can be installed singularly in lengths from 20 inches to 103 inches or joined end to end for complete perimeter heating. • A dded Safety: The sloped-top cabinet on the 905 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating. • Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes are also available. Standard Construction Features Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation. Housing – Cabinet is constructed of 18-gauge steel with a 16-gauge steel front cover. The unit has a polyester powder paint finish in white or almond. End caps are provided on all units. Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. The outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof). Built-in Controls – Linear limit, automatic reset thermal cutout. Electrical Connection – Each baseboard heater has a junction box located on both ends and a built-in full length wireway. Installation Requirements – Field or factory-installed low voltage relay and thermostat kits fit into the righthand junction box only. 75 905/907 Series C O N V E C T O R S Industrial Sill-Height Convector Industrial Sloped Top Sill-Height Convector Factory Built-in Options Code Field-Installed Options (shipped loose for field installation into heater) Description A Bottom Air Inlet D3 Disconnect Switch, 277V, Double-pole, 20 Amp Catalog Number Description Custom Length 907-124597(1) Inside Corner M1 High Altitude Automatic Cutout 907-124598(1) Outside Corner R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp 907-124599 Round Pedestal Kit, 3-5”, Qty=2 R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp 907-169807 Square Pedestal Kit, 2”, Qty=2 R6 Pneumatic Relay, 480V, 20 Amp R7 Triac Proportional Relay, 277V Max., 2500W Max. S Smooth painted finish on heater back 907-124602 24V Relay Kit, 240V, 22 Amp; 277V, 25 Amp T1 TamperproofThermostat,Single-pole,240V,25Amp; 277V, 10 Amp 907-124603 24V Relay Kit with Transformer, 120V, 22 Amp 907-124604 24V Relay Kit with Transformer, 208V, 22 Amp T2 TamperproofThermostat,Double-pole,240V,25Amp; 277V, 10 Amp 907-124605 24V Relay Kit with Transformer, 240V, 22 Amp 24V Relay Kit with Transformer, 277V, 19 Amp T5 Adjustable Thermostat, Single-pole, 240V, 25 Amp; 277V, 10 Amp 907-124606 907B-XXX(1) Blank Section (specify length in inches-XXX) (1) Change 907 prefix to 905 for sloped top. AdjustableThermostat, Double-pole, 240V, 25 Amp; 277V, 10 Amp Standard colors - Add W for white finish or A for almond finish to the end of part number. L T6 907-124600(1) Splice Plate 2” Long 907-124601(1) Contour Splice Plate for Code A (Bottom Air Inlet) and/or Heater with Pedestals Special or custom colors - See inside back cover for color codes to be added to end of part number. Remote Room Thermostat – See page 99 2-1/2" 4" K.O. 1/4" 6-1/8" 3-7/8" 1-3/8" 1-7/8" 1-1/8" 2-3/8" 15/16" Side View K.O. 7/8" Rear View 1-1/8" 7/8" 907 Series Bottom View 2-3/8" 2-1/2" 4" K.O. 1/4" 7-1/2" 3-7/8" 1-3/8" 1-7/8" 15/16" 2-1/2" 1-1/8" Rear View Side View K.O. 7/8" 76 905 Series 1-1/8" 7/8" 2-3/8" Bottom View 905/907 Series HX-907U (Flat Top) HX-905U (Sloped Top) How to order: Model + Heater Code with color code + Options (example HX-905U01200NW-1708-T5) Density Length Watts In. (mm) W/Ft W/m Heater Code 120V (1 Ph) Amps 208V (1 Ph) Amps 277V (1 Ph) Watts at Amps 240/208V Heater Code 240/208V (1 Ph) Amps 100 330 200 00200B‡-731 1.7 00200C‡-731 1.0 — — 200/150 00200V‡-731 0.8/0.7 150 490 300 00300B‡-731 2.5 00300C‡-731 1.4 00300N‡-731 1.1 300/225 00300V‡-731 1.3/1.1 200 650 400 00400B‡-731 3.3 00400C‡-731 1.9 00400N‡-731 1.4 400/300 00400V‡-731 1.7/1.4 275 900 500 00500B‡ 4.2 00500C‡ 2.4 00500N‡ 1.8 500/375 100 330 300 00300B‡-986 2.5 00300C‡-986 1.4 00300N‡-986 1.1 300/225 00300V‡-986 1.3/1.1 150 490 450 00450B‡-986 3.8 00450C‡-986 2.2 00450N‡-986 1.6 450/338 00450V‡-986 1.9/1.6 200 650 600 00600B‡-986 5.0 00600C‡-986 2.9 00600N‡-986 2.2 600/450 00600V‡-986 2.5/2.2 275 900 750 00750B‡ 6.3 00750C‡ 3.6 00750N‡ 2.7 750/563 100 330 400 00400B‡-1246 3.3 00400C‡-1246 1.9 00400N‡-1246 1.4 400/300 00400V‡-1246 1.7/1.4 150 49 (1246) 200 490 600 00600B‡-1246 5.0 00600C‡-1246 2.9 00600N‡-1246 2.2 600/450 00600V‡-1246 2.5/2.2 650 800 00800B‡-1246 6.7 00800C‡-1246 3.8 00800N‡-1246 2.9 800/600 00800V‡-1246 3.3/2.9 28.8 (731) 38.8 (986) 275 900 1000 100 330 500 00500B‡-1486 4.2 00500C‡-1486 2.4 00500N‡-1486 1.8 01000B‡ 8.3 01000C‡ 4.8 01000N‡ 3.6 58.6 150 (1486) 200 490 1000/750 00500V‡ 00750V‡ 01000V‡ 275 900 1250 1250/938 100 330 600 00600B‡-1708 5.0 00600C‡-1708 2.9 00600N‡-1708 2.2 67.3 150 (1708) 200 490 900 00900B‡-1708 7.5 00900C‡-1708 4.3 00900N‡-1708 3.2 900/675 00900V‡-1708 3.8/3.2 650 1200 01200B‡-1708 10.0 01200C‡-1708 5.8 01200N‡-1708 4.3 1200/900 01200V‡-1708 5.0/4.3 275 900 1500 100 330 76.6 150 (1945) 200 12.5 01500C‡ 7.2 01500N‡ 4.5 01250V‡ 5.4 1500/1125 01500V‡ 1050/788 01050V‡-1945 4.3/3.8 650 1400 01400B‡-1945 11.7 01400C‡-1945 6.7 01400N‡-1945 5.1 1400/1050 01400V‡-1945 5.8/5.0 330 — — 01750C‡ 8.4 01750N‡ 6.3 1750/1313 800 00800B‡-2168 6.7 00800C‡-2168 3.8 00800N‡-2168 2.9 18.7 (8.5) 17.0 (7.7) 22.0 (10.0) 18.8 (8.5) 25.0 (11.4) 20.8 (9.4) 28.3 (12.8) 31.3 (14.2) 6.3/5.4 490 1050 01050B‡-1945 8.8 01050C‡-1945 5.0 01050N‡-1945 3.8 900 1750 14.9 (6.8) 5.2/4.5 700/525 00700V‡-1945 2.9/2.5 100 15.1 (6.9) 600/450 00600V‡-1708 2.5/2.2 700 00700B‡-1945 5.8 00700C‡-1945 3.4 00700N‡-1945 2.5 275 85.4 150 (2168) 200 01500B‡ 01250N‡ 12.7 (5.8) 4.2/3.6 750/563 00750V‡-1486 3.1/2.7 6.0 11.6 (5.3) 500/375 00500V‡-1486 2.1/1.8 1000/750 01000V‡-1486 4.2/3.6 01250C‡ 10.4 (4.8) 3.1/2.7 750 00750B‡-1486 6.3 00750C‡-1486 3.6 00750N‡-1486 2.7 10.4 BII BISI (Flat) (Sloped) 2.1/1.8 650 1000 01000B‡-1486 8.3 01000C‡-1486 4.8 01000N‡-1486 3.6 01250B‡ Weight Lbs (kg) 01750V‡ 7.3/6.3 800/600 00800V‡-2168 3.3/2.9 650 1600 490 1200 01200B‡-2168 10.0 01200C‡-2168 5.8 01200N‡-2168 4.3 — 1200/900 01200V‡-2168 5.0/4.3 22.7 — 01600C‡-2168 7.7 01600N‡-2168 5.8 1600/1200 01600V‡-2168 6.7/5.8 (10.3) 275 900 2000 — — 100 330 02000C‡ 9.6 02000N‡ 7.2 2000/1500 900 00900B‡-2393 7.5 00900C‡-2393 4.3 00900N‡-2393 3.2 02000V‡ 8.3/7.2 900/675 00900V‡-2393 3.8/3.2 94.2 150 (2393) 200 490 1350 — 650 1800 — — 01350C‡-2393 6.5 01350N‡-2393 4.9 1350/1013 01350V‡-2393 5.6/4.9 24.6 — 01800C‡-2393 8.7 01800N‡-2393 6.5 1800/1350 01800V‡-2393 7.5/6.5 (11.2) 275 900 2250 — — 100 330 1000 01000B‡-2625 8.3 01000C‡-2625 4.8 01000N‡-2625 3.6 02250C‡ 10.8 02250N‡ 8.1 2250/1688 02250V‡ 9.4/8.1 490 1500 — — 01500C‡-2625 7.2 01500N‡-2625 5.4 1500/1125 01500V‡-2625 6.3/5.4 650 2000 — — 02000C‡-2625 9.6 02000N‡-2625 7.2 2000/150002000V‡-26252 8.3/7.2 650 2250 — — 02250C‡-2625 10.8 02250N‡-2625 8.1 2250/1688 02250V‡-2625 9.4/8.1 275 900 2500 — — 12.0 02500N‡ 34.4 (15.6) 1000/750 01000V‡-2625 4.2/3.6 150 103.4 200 (2625) 200 02500C‡ C O N V E C T O R S Industrial Sill-Height Convector Industrial Sloped Top Sill-Height Convector 9.0 2500/1875 02500V‡ 26.6 (12.1) 37.6 (17.1) 10.4/9.0 Other single-phase voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated. 77 908/909 Series C O N V E C T O R S Architectural Convector Architectural Sloped Top Convector 909 908 Applications •Banks •Halls •Classrooms •Offices The 908/909 Series architectural convectors are designed to heat large commercial spaces without the fan noise associated with unit heaters. • Installation Options: Units may be mounted to the wall, flush on the floor or on pedestals. Custom lengths, blank sections, sub-bases and inside or outside corners are available for wall-to-wall installations. Units and accessories can be ordered with smooth painted finish when the back of the heater is visible. • Added Safety: The sloped-top cabinet on the 908 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating. • Recessed Mounting: The 909 Series heater can be fully recessed when the front warm air outlet option is used. • C hoice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes are also available. • Conference Rooms Standard Construction Features Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation. Housing – Cabinet is constructed of 20-gauge steel with a 16-gauge steel front cover. The unit has a polyester powder paint finish in white or almond. Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. An extruded aluminum outlet grille discourages tampering with the heating element. 78 Built-in Controls – Linear limit, automatic reset thermal cutout. Installation Requirements – Field or factory-installed low voltage relay and thermostat kits. Rough In Dimensions – 909 only: Heater Length + 1” wide x 15” high x 6” deep. 908/909 Series Factory Built-in Options Code D1 Description Disconnect Switch, Three-pole, 600V, 40 Amp Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description F Front Air outlet (Flat Top Only) R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R3 24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp R4 240V Relay, Single-pole, 240V, 25 Amp R5 240V Relay, Double-pole, 240V, 25 Amp R6 Pneumatic Relay, 480V, 20 Amp R7 Triac Proportional Relay, 277V Max., 2500W Max. S Smooth painted finish on heater back 909-124615 T1 TamperproofThermostat,Single-pole,240V,30Amp; 480V, 15 Amp 909-124616 75.2 (1909) 909-124617 83.2 (2112) T2 TamperproofThermostat,Double-pole,480V,15Amp 909-218276(1) 27.2 (690) X1 240V Transformer - 50 VA 909-218277(1) 37.2 (944) X2 24V Transformer - 50 VA 909-218278(1) 909-124609 Flat Top Corner (interior and exterior) 908-124609 Sloped Top inside corner 908-218356 Sloped Top outside corner 909-124610 Square Pedestal Kit 27.2 (690) 909-124612 37.2 (944) 909-124614 909-218279(1) 909-218280(1) Remote Room Thermostat – See page 99 Sub Base Heater Length In. (mm) Empty Cabinet Length In. (mm) 47.2 (1198) 57.2 (1452) 65.2 (1655) 83.2 (2112) 909-124608 27.2 (690) 909-124619 37.2 (944) Recessed Trim Kit Heater Length In. (mm) 47.2 (1198) 57.2 (1452) 65.2 (1655) 909-124623 75.2 (1909) 909-124624 83.2 (2112) 909-124625(1) 909-124626(1) 909-124627(1) Filler Section Length In. (mm) 909-124628(1) Control Box - 12” Filler sections can be cut to length in the field. 65.2 (1655) 909-218282(1) 909-124622 Special or custom colors - See inside back cover for color codes to be added to end of part number. 57.2 (1452) 75.2 (1909) 909-124621 Standard colors - Add W for white finish or A for almond finish to the end of part number. 47.2 (1198) 909-218281(1) 909-124620 (1) Change 909 prefix to 908 for sloped top. 3-4” High 909-124611 909-124613 C O N V E C T O R S Architectural Convector Architectural Sloped Top Convector 12 (305) 24 (610) 36 (914) 12 (306) 909-124629 24V Relay Kit, Single-pole, 240V, 22 Amp; 277V, 19 Amp 909-124630 24V Relay Kit, Double-pole, 240V, 25 Amp 909-124631 240V Relay Kit, Single-pole, 240V, 22 Amp 909-124632 240V Relay Kit, Double-pole, 240V, 25 Amp 909-124633 24V Relay Kit with Transformer, 208V, 22 Amp 909-124634 24V Relay Kit with Transformer, 240V, 22 Amp 909-124635 24V Relay Kit with Transformer, 277V, 19 Amp 909-124636 Transformer Kit-208/24V - 50 VA 909-124637 Transformer Kit-240/24V - 50 VA 909-124638 Transformer Kit-277/24V - 50 VA 79 908/909 Series C O N V E C T O R S Architectural Convector Architectural Sloped Top Convector Unit With Grille On Top Not recessed Unit With Grille On Front (Option F) 7-1/2" Front View 14" 2" 8-1/2" 4-1/2" 3" K.O. Ø1-1/8 - Ø7/8" K.O. Ø1/4" K.O. Ø7/8" Right Side View K.O.Ø1/4" 8-1/32" 4" K.O.Ø1-1/8"Ø7/8" 2" 2-1/4" 5-3/1 2" Bottom View 909 Series 2-1/32" 2-1/32" K.O. 1-1/8" 4" 7-17/32" 4" K.O. 7/8" 2" K.O. 1/4" 4-1/32" 14-1/16" 2-27/32" 4-15/32" 2" L Rear View K.O. 1/4" Front View 2-21/32" 908 Series 2-1/32" K.O. 1-1/8" 2" 5-3/16" 2-9/32" 2-21/32" Bottom View 80 2-31/32" 4-15/32" 2-1/32" Left Side View 908/909 Series HX-909U (Flat Top) HX-908U (Sloped Top) How to order: Model + Heater Code with color code + Options (example HX-909U02000NW-1655-T1) Density Length In. (mm) W/Ft 27.2 (690) 375 1250 500 1640 375 1250 500 37.2 (944) Heater Code Watts Heater Code 208V (1 Ph) Amps 277V (1 Ph) Amps 800 00800C‡-690 3.8 00800N‡-690 2.9 1000 01000C‡ 4.8 01000N‡ 3.6 1000 01000C‡-944 4.8 01000N‡-944 3.6 1640 1500 01500C‡ 7.2 01500N‡ W/m Watts at 240/208V 240/208V (1 Ph) Amps 800/600 00800V‡-690 3.3/2.9 1000/750 01000V‡ 4.2/3.6 1000/750 01000V‡-944 4.2/3.6 5.4 1500/1125 01500V‡ 6.3/5.4 47.2 (1198) 375 1250 1500 01500C‡-1198 7.2 01500N‡-1198 5.4 1500/1125 01500V‡-1198 6.3/5.4 500 1640 2000 02000C‡ 9.6 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2 57.2 (1452) 375 1250 1750 01750C‡-1452 8.4 01750N‡-1452 6.3 1750/1313 01750V‡-1452 7.3/6.3 500 1640 2500 02500C‡ 12.0 02500N‡ 9.0 2500/1875 02500V‡ 10.4/9.0 375 1250 2000 02000C‡-1655 9.6 02000N‡-1655 7.2 2000/1500 02000V‡-1655 8.3/7.2 500 1640 3000 03000C‡ 14.4 03000N‡ 10.8 3000/2250 03000V‡ 12.5/10.8 75.2 (1909) 375 1250 2500 02500C‡-1909 12.0 02500N‡-1909 9.0 2500/1875 02500V‡-1909 10.4/9.0 500 1640 3500 03500C‡(1) 16.8 03500N‡ 12.6 3500/2625 03500V‡ 14.6/12.6 83.2 (2112) 375 1250 2750 02750C‡-2112 13.2 02750N‡-2112 9.9 2750/2066 02750V‡-2112 11.5/9.9 500 1640 4000 04000C‡(1) 19.2 04000N‡ 14.4 4000/3000 04000V‡ 16.7/14.4 65.2 (1655) Weight Lbs (kg) BAI (Flat) BASI (Sloped) 30 (13.6) 32.0 (14.5) 46 (20.9) 46 (20.9) 57 (25.9) 57 (25.9) 66 (29.9) 66 (30) 75 (34.0) 75 (34.1) 80 (36.3) 80 (36.3) 89 (40.4) 89 (40.5) C O N V E C T O R S Architectural Convector Architectural Sloped Top Covector Other single-phase voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated. (1) If control option R7 is required for these heaters, (Qty 2) R7 Triac proportional relays are required. 81 914 Series D R A F T B A R R I E R S Mini Draft Barrier Heater Applications • Commercial Buildings •Entryways •Hallways •Schools The 914 Series mini draft barrier heaters are designed to fit under large windows to prevent cold down drafts. The heater provides total or supplemental heating for a variety of applications. • Installation Options: Units may be wall mounted or installed on the floor using pedestal kits. Custom lengths, blank sections, and inside or outside corners are available for wall-to-wall installations. Units can be ordered with smooth painted finish mounting plates when the back of the heater is visible. • Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes including anodized aluminum are available. Standard Construction Features Heating Elements – Stainless steel elements with alumi- num fins float on high temperature nylon bushings for quiet operation. Housing – Cabinet is constructed of 18-gauge steel with a 14-gauge aluminum front and top covers. The unit has a polyester powder paint finish in white or almond. End caps are provided on all units. Inlet/Outlet Grilles – The fresh air inlet is located on the bottom of the unit. The top outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof). 82 Built-in Controls – Linear limit, automatic reset thermal cutout. Electrical Connection – Each heater has a junction box located at the right end and a built-in full length wireway. Separate low voltage wireway is available. Mounting Requirements – Minimum installation height above the floor is two inches. Field or factory-installed low voltage relay and thermostat kits fit into the righthand junction box only. 914 Series Factory Built-in Options (shipped loose for field installation into heater) Description D3 Disconnect Switch, Double-pole, 277V, 20 Amp F1 24V Wireway L Custom Length M1 High Altitude Automatic Cutout R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R6 Pneumatic Relay, 480V, 20 Amp R7 Triac Proportional Relay 277V Max., 2500W Max. S Smooth painted finish on heater back T1 TamperproofThermostat,Single-pole, 240V,25 Amp; 600V, 10 Amp T2 TamperproofThermostat,Double-pole,240V,25Amp; 600V, 10 Amp T5 Adjustable Thermostat, Single-pole, 240V, 25 Amp; 600V, 10 Amp T6 Adjustable Thermostat, Double-pole, 240V, 25Amp; 600V, 10 Amp Catalog Number Description 914-166740 Inside Corner 914-166741 Outside Corner 914-166742 Round Pedestal Kit, 3-5”, Qty 2 914-166743 Square Pedestal Kit, 2”, Qty 2 914-166744 Splice Plate 2” Long 914-166745 ContouredSplicePlateforCodeS(smoothpainted finishonheaterback)and/orHeaterwithPededstals 914-166746 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp 914-166747 24V Relay Kit with Transformer, 208V, 22 Amp 914-166748 24V Relay Kit with Transformer, 240V, 22 Amp 914-166749 24V Relay Kit with Transformer, 277V 19 Amp 914B-XXX Blank Section (specify length in inches-XXX) B A R R I E R S Code Field-Installed Options D R A F T Mini Draft Barrier Heater Standard colors - Add W for white finish or A for almond finish to the end of part number. Special or custom colors - See inside back cover for color codes to be added to end of part number. Remote Room Thermostat – See page 99 2-1/2" Top View Top View 2-1/2" 4-1/2" Top View 2" 3-3/16" 2" Rear View RearView K.O.O7/8" K.O.O7/8" 3-3/4" Smooth Finish on ter hea back - (S) Standard inish F on er heat back RearView 3-3/16" 3-3/4" Smooth Finish on ter hea back - (S) Standard inish F on er heat back FrontView Front View FrontView 1" 4-1/2" 1-5/8" 1" Side Vie w Side View 1-5/8" SideView Sufficie ntHeight 2" rom f Floor Sufficie ntHeight 2" rom f Floor Shown with optional square pedestal. 83 914 Series B A R R I E R S Mini Draft Barrier Heater HX-914U How to order: Model + Heater Code with color code + Options (example HX-914U00400NW-1200-T5) D R A F T Density Length Watts In. (mm) W/Ft W/m 27.6 (700) 35.4 (900) 47.3 (1200) 59.1 (1500) 70.9 (1800) 82.7 (2100) 94.5 (2400) Heater Code 208V (1 Ph) Amps 277V (1 Ph) Amps 480V (1 Ph) Heater Code Watts Amps 240/208V 240/208V (1 Ph) 150 490 300 00300C‡-700 1.4 00300N‡-700 1.1 — — 300/225 175 574 350 00350C‡ 1.7 00350N‡ 1.3 — — 350/263 00300V‡-700 1.3/1.1 100 330 300 00300C‡-900 1.4 00300N‡-900 1.1 00300T‡-900 0.6 300/225 00300V‡-900 1.3/1.1 150 490 450 00450C‡-900 2.2 00450N‡-900 1.6 00450T‡-900 0.9 450/338 00450V‡-900 1.9/1.6 175 574 525 00525C‡ 2.5 00525N‡ 1.9 00350V‡ 00525T‡ 1.1 525/394 1.9 00400N‡-1200 1.4 00400T‡-1200 0.8 400/300 00400V‡-1200 1.7/1.4 150 490 600 00600C‡-1200 2.9 00600N‡-1200 2.2 00600T‡-1200 1.3 600/450 00600V‡-1200 2.5/2.2 175 574 700 3.4 00700T‡ 1.5 700/526 00700C‡ 00700N‡ 2.5 00525V‡ 1.5/1.3 100 330 400 00400C‡-1200 00700V‡ 2.4 00500N‡-1500 1.8 00500T‡-1500 1.0 500/375 00500V‡-1500 2.1/1.8 3.6 00750N‡-1500 2.7 00750T‡-1500 1.6 750/563 00750V‡-1500 3.1/2.7 175 574 875 4.2 00875T‡ 1.8 875/657 00875N‡ 3.2 00875V‡ 2.9 00600N‡-1800 2.2 00600T‡-1800 1.3 600/450 00600V‡-1800 2.5/2.2 150 490 900 00900C‡-1800 4.3 00900N‡-1800 3.2 00900T‡-1800 1.9 900/675 00900V‡-1800 3.8/3.2 175 574 1050 5.0 01050T‡ 2.2 1050/789 01050N‡ 3.8 01050V‡ 3.4 00700N‡-2100 2.5 00700T‡-2100 1.5 700/525 150 490 1050 01050C‡-2100 5.0 01050N‡-2100 3.8 01050T‡-2100 2.2 1050/788 01050V‡-2100 4.4/3.8 175 574 1225 5.9 01225T‡ 2.6 1225/920 3.8 00800N‡-2400 2.9 00800T‡-2400 1.7 800/600 150 490 1200 01200C‡-2400 5.8 01200N‡-2400 4.3 01200T‡-2400 2.5 1200/900 01200V‡-2400 5.0/4.3 175 574 1400 6.7 01400T‡ 2.9 1400/1052 01400N‡ 4.4 5.1 12 (5.5) 13.9 (6.3) 00700V‡-2100 2.9/2.5 100 330 800 00800C‡-2400 01400C‡ 01225N‡ 10.2 (4.6) 4.4/3.8 100 330 700 00700C‡-2100 01225C‡ 8.3 (3.8) 3.6/3.2 100 330 600 00600C‡-1800 01050C‡ 7 (3.2) 2.9/2.5 100 330 500 00500C‡-1500 00875C‡ Weight Lbs (kg) 2.2/1.9 150 490 750 00750C‡-1500 01225V‡ 15.8 (7.2) 5.1/4.4 00800V‡-2400 3.3/2.9 Other voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated 84 Amps 01400V‡ 5.8/5.1 17.6 (8) 916 Series D R A F T High Watt Density Draft Barrier B A R R I E R S Applications • Commercial Buildings •Hospitals •Entryways • Shopping Centers •Hallways The 916 Series high watt density draft barrier heaters are designed to fit under large windows to prevent cold down drafts. The heater provides total or supplemental heating for a variety of applications. • Installation Options: Units may be wall mounted or installed on the floor using pedestal kits. Custom lengths, blank sections and inside or outside corners are available for wall-to-wall installations. Units can be ordered with smooth painted finish when the back of the heater is visible. • Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes, including anodized aluminum, are also available. Standard Construction Features Heating Elements – Two stainless steel elements Built-in Controls – Linear limit, automatic reset thermal with aluminum fins float on high temperature nylon bushings for quiet operation. cutout. Housing – Cabinet is constructed of 18-gauge steel with located at the right end and a built-in full length wireway. Seprate low voltage wireway is available. a 14-gauge aluminum front and top covers. The unit has a polyester powder paint finish in white or almond. End caps are provided on all units. Inlet/Outlet Grilles – The fresh air inlet is located on the bottom of the unit. The top outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof). Electrical Connection – Each heater has a junction box Installation Requirements – Minimum installation height above the floor is three inches. Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junction box only. 85 916 Series B A R R I E R S High Watt Density Draft Barrier Heater Factory Built-in Options D R A F T Code Field-Installed Options (shipped loose for field installation into heater) Description D1 Disconnect Switch, Three-pole, 600V, 40 Amp D3 Disconnect Switch, Double-pole, 277V, 20 Amp F1 24V Wireway L Custom Length Catalog Number M1 High Altitude Automatic Cutout R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R6 Pneumatic Relay, 480V, 20 Amp R7 Triac Proportional Relay 277V Max., 2500W Max. S Smooth painted finish on heater back T1 TamperproofThermostat,Single-pole, 240V, 25Amp; 600V, 10 Amp T2 TamperproofThermostat,Double-pole,240V,25Amp; 600V, 10 Amp Description 916-166753 Inside Corner 916-166754 Outside Corner 916-166756 Square Pedestal Kit, 3”, Qty 2 916-166757 Splice Plate 2” Long 916-166758 ContouredSplicePlateforCodeS(smoothpainted finishonheaterback)and/orHeaterwithPededstals 916-166759 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp 916-166760 24V Relay Kit with Transformer, 208V, 22 Amp 916-166761 24V Relay Kit with Transformer, 240V, 22 Amp 916-166762 24V Relay Kit with Transformer, 277V 19 Amp 916B-XXX Blank Section (specify length in inches-XXX) Standard colors - Add W for white finish or A for almond finish to the end of part number. Special or custom colors - See inside back cover for color codes to be added to end of part number. Remote Room Thermostat – See page 99 5-3/4" Top TopView View O1/4" 6" 3" 1-7/8" K.O. O7/8" RearView View Rear Front View 2-1/4" 3-3/16" Smooth Finish on heater back - (S) Standard Finish on heater back 3-3/16" Side SideView View Shown with optional square pedestals. Front View Sufficient Height 3” from Floor 86 916 Series Density Length In. (mm) 23.6 (600) 35.4 (900) 47.3 (1200) 59.1 (1500) 70.9 (1800) 82.7 (2100) 94.5 (2400) Heater Code Heater Code Watts at Amps 240/208V Watts 208V (1 Ph) Amps 277V (1 Ph) Amps 480V (1 Ph) 575 375 00375C‡-600 1.8 00375N‡-600 1.4 — — 250 820 500 00500C‡-600 2.4 00500N‡-600 1.8 — 355 1165 750 00750C‡ 3.6 00750N‡ 2.7 500 1640 1000 01000C‡-600 4.8 01000N‡-600 175 575 500 00500C‡-900 2.4 00500N‡-900 250 820 750 00750C‡-900 3.6 355 1165 1000 01000C‡ 500 1640 1500 01500C‡-900 175 575 700 250 240/208V (1 Ph) Amps 375/281 00375V‡-600 1.6/1.4 — 500/375 00500V‡-600 2.1/1.8 — — 750/563 00500V‡ 3.1/2.7 3.6 01000T‡-600 2.1 1000/750 01000V‡-600 4.2/3.6 1.8 00500T‡-900 1.0 500/375 00500V‡-900 2.1/1.8 00750N‡-900 2.7 00750T‡-900 1.6 750/563 00750V‡-900 3.1/2.7 4.8 01000N‡ 3.6 01000T‡ 2.1 1000/751 01000V‡ 4.2/3.6 7.2 01500N‡-900 5.4 01500T‡-900 00700C‡-1200 3.4 00700N‡-1200 2.5 00700T‡-1200 1.5 700/525 820 1000 01000C‡-1200 4.8 01000N‡-1200 3.6 01000T‡-1200 2.1 1000/750 01000V‡-1200 4.2/3.6 355 1165 1400 01400N‡ 5.1 500 1640 2000 02000C‡-1200 9.6 02000N‡-1200 7.2 02000T‡-1200 4.2 2000/1500 02000V‡-1200 8.3/7.2 175 575 875 00875C‡-1500 4.2 00875N‡-1500 3.2 00875T‡-1500 1.8 875/656 250 820 1250 01250C‡-1500 6.0 01250T‡-1500 2.6 1250/938 01250V‡-1500 5.2/4.5 355 1165 1750 500 1640 2500 02500C‡-1500 175 W/Ft W/m 175 01400C‡ 6.7 01400T‡ 3.1 1500/1125 01500V‡-900 2.9 1400/1052 01400V‡ 5.8/5.1 4.5 6.3 12 02500N‡-1500 9.0 02500T‡-1500 5.2 2500/1875 02500V‡-1500 10.4/9.0 575 1050 01050C‡-1800 5.0 01050N‡-1800 3.8 01050T‡-1800 2.2 250 820 1500 01500C‡-1800 7.2 01500N‡-1800 5.4 01500T‡-1800 3.1 1500/1125 01500V‡-1800 6.3/5.4 355 1165 2100 02100N‡ 7.6 500 1640 3000 03000C‡-1800 14.4 03000N‡-1800 10.8 03000T‡-1800 6.3 3000/2250 03000V‡-1800 12.5/10.8 02100C‡ 10.1 02100T‡ 01750V‡ 7.3/6.3 4.4 2100/1577 02100V‡ 8.8/7.6 175 575 1225 01225C‡-2100 5.9 01225N‡-2100 4.4 01225T‡-2100 2.6 820 1750 01750C‡-2100 8.4 01750N‡-2100 6.3 01750T‡-2100 3.6 1750/1313 01750V‡-2100 7.3/6.3 355 1165 2450 02450N‡ 8.8 500 1640 3500 03500C‡-2100 16.8 03500N‡-2100 12.6 03500T‡-2100 7.3 3500/2625 03500V‡-2100 14.6/12.6 11.8 02450T‡ 5.1 2450/1840 02450V‡ 10.2/8.8 175 575 1400 01400C‡-2400 6.7 01400N‡-2400 5.1 01400T‡-2400 2.9 1400/1050 01400V‡-2400 5.8/5.0 820 2000 02000C‡-2400 9.6 02000N‡-2400 7.2 02000T‡-2400 4.2 2000/1500 02000V‡-2400 8.3/7.2 355 1165 2800 02800N‡ 10.1 500 1640 4000 04000C‡-2400 19.2 04000N‡-2400 14.4 04000T‡-2400 8.3 4000/3000 04000V‡-2400 16.7/14.4 13.5 02800T‡ 24.6 (11.1) 1225/919 01225V‡-2100 5.1/4.4 250 02800C‡ 21.1 (9.6) 1050/788 01050V‡-1800 4.4/3.8 250 02450C‡ 17.6 (8.0) 00875V‡-1500 3.6/3.2 01750N‡ 3.6 1750/1314 14.1 (6.4) 00700V‡-1200 2.9/2.5 01250N‡-1500 01750T‡ 10.7 (4.8) 6.3/5.4 8.4 01750C‡ Weight Lbs (kg) B A R R I E R S HZ-916U How to Order: Model + Heater Code with color code + Options (example HX-916U00875CW-1500-T1) D R A F T High Watt Density Draft Barrier 5.8 2800/2103 02800V‡ 28.0 (12.7) 31.5 11.7/10.1 (14.3) Other voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated. 87 911/912 Series C O N V E C T O R S Architectural Cabinet Convector Architectural Sloped Top Cabinet Convector 912 911 Applications The 911/912 convectors are designed to heat large commercial spaces. They provide large amounts of heat without the fan noise associated with unit heaters. • Installation Options: Units may be mounted to the wall, flush on the floor or on pedestals. 912 Series units can be fully recessed when the front warm air outlet option is used. • A dded Safety: The sloped-top cabinet on the 911 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating. • W all-to-Wall Installation: A finished back mounting plate is available so that the unit can be mounted against glass walls. •Classrooms • Conference Rooms •Hallways •Lobbies Standard Construction Features Heating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation. Housing – Cabinet is constructed of 20-gauge steel with a 16-gauge steel front cover. The unit has a polyester powder paint finish in white or almond. Mounting holes are provided along the back of the cabinet for wall installation. 88 Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. An extruded aluminum outlet grille discourages tampering with the heating elements. Built-in Controls – Linear limit, automatic reset thermal cutout. Rough In Dimensions – 912 Series only: Heater Length + 1” wide x 21” high x 6” deep. 911/912 Series Factory Built-in Options Code D1 Description Disconnect Switch, Three-pole, 600V, 40 Amp F Front Air outlet (912 Series Only) R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R3 R4 Field-Installed Options (shipped loose for field installation into heater) Catalog Number Description 912-124546 Flat Top Corner (interior and exterior) 911-124546 Sloped Top inside corner 911-218358 Sloped Top outside corner 24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp 912-124547 UniversalRoundPedestalKit 3-4” High 240V Relay, Single-pole, 240V, 25 Amp 912-124548 27.2 (690) R5 240V Relay, Double-pole, 240V, 25 Amp 912-124549 R6 Pneumatic Relay, 480V, 20 Amp 912-124550 R7 Triac Proportional Relay, 277V Max., 2500W Max. 912-124551 S Smooth painted finish on heater back 912-124552 65.2 (1655) T1 TamperproofThermostat,Single-pole,240V,30Amp; 480V, 15 Amp 912-218283(1) 27.2 (690) 912-218284(1) Sub Base Heater Length In. (mm) Empty Cabinet Length In. (mm) 37.2 (944) 47.2 (1198) 57.2 (1452) 37.2 (944) T2 TamperproofThermostat,Double-pole,480V,15Amp 912-218285(1) X1 240V Transformer - 50 VA 912-218286(1) X2 24V Transformer - 50 VA 912-218287(1) 65.2 (1655) 912-124553 27.2 (690) 912-124554 912-124555 Remote Room Thermostat – See page 99 912-124556 Recessed Trim Kit Heater Length In. (mm) 912-124557 912-124558(1) 912-124559(1) 912-124560(1) 47.2 (1198) 57.2 (1452) 37.2 (944) 47.2 (1198) 57.2 (1452) 65.2 (1655) Filler Section Length In. (mm) 912-124561(1) Control Box - 12” 12 (305) 24 (610) 36 (914) 12 (306) 912-124562 24V Relay Kit, Single-pole, 240V, 22 Amp; 277V, 19 Amp 912-124563 24V Relay Kit, Double-pole, 240V, 25 Amp; 277V, 19 Amp 912-124564 240V Relay Kit, Double-pole, 240V, 25 Amp 912-124565 240V Relay Kit, Single-pole, 240V, 22 Amp 912-124566 24V Relay Kit with Transformer, 208V, 22 Amp 912-124567 24V Relay Kit with Transformer, 240V, 22 Amp (1) Change 912 prefix to 911 for sloped top. 912-124568 24V Relay Kit with Transformer, 277V, 19 Amp Standard colors - Add W for white finish or A for almond finish to the end of part number. 912-124569 Transformer Kit-208/24V - 50 VA 912-124570 Transformer Kit-240/24V - 50 VA 912-124571 Transformer Kit-277/24V - 50 VA Special or custom colors - See inside back cover for color codes to be added to end of part number. Filler sections can be cut to length in the field. C O N V E C T O R S Architectural Cabinet Convector Architectural Sloped Top Cabinet Convector 89 911/912 Series C O N V E C T O R S Architectural Cabinet Convector Architectural Sloped Top Cabinet Convector Unit With Grille On Top K.O. 4" X 2" 7-1/4" K.O. ¯ 1/4" K.O. ¯ 7/8" 2-1/2" 8" 8-1/2" K.O. ¯ 7/8" 12-1/2" 6" Unit With Grille On Front (Option F) 5-3/16" Rear View 20-3/16" Left Side View K.O. ¯ 7/8" 2" Bottom View L 912 Series K.O. ¯ 7/8" K.O. ¯ 1/4" 2" 20-3/16" 8-15/32" 2" 8" K.O. ¯ 1-1/8" 6" L 4-1/32" Rear View 5-3/16" Front View Left Side View K.O. ¯ 1/4" K.O. ¯ 1-1/8" 911 Series 90 2" 2" Bottom View 911/912 Series HX-912U (Flat Top) HX-911U (Sloped Top) How to order: Model + Heater Code with color code + Options (example: HX-912U03000CW-1198-T1) Density Length In. (mm) W/Ft W/m Heater Code Watts 208V (1 ph) Amps 240V (1 ph) Amps 277V (1 ph) Amps Heater Code Watts at 240/208V 240/208V (1 ph) Amps 500 1640 1000 01000C‡-690 4.8 01000J‡-690 4.2 01000N‡-690 3.6 1000/750 01000V‡-690 4.2/3.6 27.2 (690) 750 2450 1500 01500C‡-690 7.2 01500J‡-690 6.3 01500N‡-690 5.4 1500/1125 01500V‡-690 6.3/5.4 1000 3280 2000 02000C‡ 9.6 02000J‡ 8.3 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2 500 1640 1500 01500C‡-944 7.2 01500J‡-944 6.3 01500N‡-944 5.4 1500/1125 01500V‡-944 6.3/5.4 37.2 (944) 750 2450 2250 02250C‡-944 10.8 02250J‡-944 9.4 02250N‡-944 8.1 2250/1690 02250V‡-944 9.4/8.1 1000 3280 3000 03000C‡ 14.4 03000J‡ 12.5 03000N‡ 10.8 3000/2250 03000V‡ 12.5/10.8 500 1640 2000 02000C‡-1198 9.6 02000J‡-1198 8.3 02000N‡-1198 7.2 2000/1500 02000V‡-1198 8.3/7.2 750 2450 3000 03000C‡-1198 14.4 03000J‡-1198 12.5 03000N‡-1198 10.8 3000/2250 03000V‡-1198 12.5/10.8 1000 3280 4000 04000C‡ 19.2 04000J‡ 16.7 04000N‡ 14.4 4000/3000 04000V‡ 16.7/14.4 500 1640 2500 02500C‡-1452 12.0 02500J‡-1452 10.4 02500N‡-1452 9.0 2500/1875 02500V‡-1452 10.4/9.0 750 2450 3750 03750C‡-1452 18.0 03750J‡-1452 15.6 03750N‡-1452 13.5 3750/2817 03750V‡-1452 15.6/13.5 1000 3280 5000 05000C‡ 24.0 05000J‡ 20.8 05000N‡ 18.1 5000/3750 500 1640 3000 03000C‡-1655 14.4 03000J‡-1655 12.5 03000N‡-1655 10.8 3000/2250 03000V‡-1655 12.5/10.8 750 2450 4500 04500C‡-1655 21.6 04500J‡-1655 18.8 04500N‡-1655 16.2 4500/3380 04500V‡-1655 18.8/16.3 1000 3280 6000 06000C‡ 28.8 06000J‡ 25.0 06000N‡ 21.7 6000/4500 Density Length In. (mm) W/Ft W/m Watts 208V (3 ph) Amps 240V (3 ph) Amps 480V (3 ph) Amps Watts at 240/208V 47.2 (1198) 57.2 (1452) 65.2 (1655) Heater Code 05000V‡ 06000V‡ Heater Code 240/208V (3 ph) Amps 1000 01000D‡-690 2.8 01000K‡-690 2.4 01000U‡-690 1.2 1000/750 01000P‡-690 2.8/2.1 27.2 (690) 750 2450 1500 01500D‡-690 4.2 01500K‡-690 3.6 01500U‡-690 1.8 1500/1125 01500P‡-690 3.6/3.1 1000 3280 2000 02000D‡ 5.6 02000K‡ 4.8 02000U‡ 2.4 2000/1500 02000P‡ 4.8/4.2 500 1640 1500 01500D‡-944 4.2 01500K‡-944 3.6 01500U‡-944 1.8 1500/1125 01500P‡-944 3.6/3.1 37.2 (944) 750 2450 2250 02250D‡-944 6.2 02250K‡-944 5.4 02250U‡-944 2.7 2250/1690 02250P‡-944 5.4/4.7 1000 3280 3000 03000D‡ 8.3 03000K‡ 7.2 03000U‡ 3.6 3000/2250 03000P‡ 7.2/6.2 500 1640 2000 02000D‡-1198 5.6 02000K‡-1198 4.8 02000U‡-1198 2.4 2000/1500 02000P‡-1198 4.8/4.2 750 2450 3000 03000D‡-1198 8.3 03000K‡-1198 7.2 03000U‡-1198 3.6 3000/2250 03000P‡-1198 7.2/6.2 1000 3280 4000 04000D‡ 11.1 04000K‡ 9.6 04000U‡ 4.8 4000/3000 04000P‡ 9.6/8.3 65.2 (1655) 911 (Sloped) 37 (16.8) 37 (16.8) 47 (21.3) 47 (21.3) 57 (25.9) 57 (25.9) 67 (30.4) 67 (30.4) 79 (35.8) 79 (35.8) 25.0/21.6 1640 57.2 (1452) 912 (Flat) 20.8/18.0 500 47.2 (1198) Weight Lbs (kg) C O N V E C T O R S Architectural Convector Architectural Sloped Top Convector 500 1640 2500 02500D‡-1452 6.9 02500K‡-1452 6.0 02500U‡-1452 3.0 2500/1875 02500P‡-1452 6.0/5.2 750 2450 3750 03750D‡-1452 10.4 03750K‡-1452 9.0 03750U‡-1452 4.5 3750/2817 03750P‡-1452 9.0/7.8 1000 3280 5000 05000D‡ 13.9 05000K‡ 12.0 05000U‡ 6.0 5000/3750 05000P‡ 12.0/10.4 500 1640 3000 03000D‡-1655 8.3 03000K‡-1655 7.2 03000U‡-1655 3.6 3000/2250 03000P‡-1655 7.2/6.2 750 2450 4500 04500D‡-1655 12.5 04500K‡-1655 10.8 04500U‡-1655 5.4 4500/3380 04500P‡-1655 10.8/9.4 1000 3280 6000 06000D‡ 16.7 06000K‡ 14.4 06000U‡ 7.2 6000/4500 06000P‡ 14.4/12.5 Weight Lbs (kg) 912 (Flat) 911 (Sloped) 37 (16.8) 37 (16.8) 47 (21.3) 47 (21.3) 57 (25.9) 57 (25.9) 67 (30.4) 67 (30.4) 79 79 (35.8) (35.8) Other voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated. Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated. For three-phase units a double pole relay or thermostat is required. 91 H E A T E R S AS R A D I A N T Radiant Ceiling Panels Applications •Atriums •Lobbies • Enclosed Walkways •Offices •Entryways •Schools •Hospitals •Warehouses AS Series radiant panels are ideal for offsetting heat loss through exterior glass on the perimeter of a building. They help to control the problem of condensation typically found with these large exterior glass walls. Radiant panels provide improved comfort by maintaining an even temperature from floor to ceiling. • R adiant Heat: Radiant energy travels in straight lines and is absorbed by objects in the room, warming the space. Air quality is maintained because no forced air movement occurs with radiant heating. • M aximize Work Area: Ceiling mounted panels permit full use of floor and wall space. • M aintenance Free: Radiant panels have no moving parts, so they are maintenance free and can provide years of quiet, safe and clean operation. Standard Construction Features Heating Element – High quality alloy resistance wire is electrically insulated with a UL Listed TEFZEL® compound rated for 200°C (392°F). Heating wires are covered with high-efficiency reflective foil. Panel Design – Panel is made of 22-gauge galva- nized steel with a white baked-on powder paint finish. Panel is crimped, not riveted, for improved strength. Insulation – Each panel contains two inches of high temperature/high density mineral wool insulation. Electrical – A junction box is attached to each panel for field wiring and to connect panels to each other. 92 Installation Requirements – Heater can be installed in suspended T-bar ceiling systems or can be surface or recessed mounted using optional mounting frames. Heater comes equipped with four suspension clips. Connecting wire or chain is supplied by customer. Minimum recommended mounting height is eight feet from the floor. Rough In Dimensions – Plaster Mounting Frames: • PF-22: 24-1/8” x 24-1/8” • PF-24 and SPF 24: 24-1/8” x 48-1/8” • PF-1448: 14-18” x 48-1/8” • PF-1460: 14-1/8” x 60-1/8” AS Factory Built-in Options Description Code S Silicone seams, provides protection in high moisture areas. Includes 36” of sealtite conduit. TEG Tegular reveal edge detail for 15/16” grid. TEGF Fineline Tegular reveal edge for 9/16” grid. Width Length Weight Catalog In. (mm) In. (mm) lb (kg) Number Surface Mounting Frames SF-22 24 (610) 24 (610) 4 (1.8) SF-24 24 (610) 48 (1219) 9 (4.1) SF-1448 14 (356) 48 (1219) 8 (3.6) SF-1460 14 (356) 60 (1524) 10 (4.5) Plaster Mounting Frames Finishes Description Code O Specify custom color finish. PT Standard finish; textured white baked-on powder coating on front panel. S304 304 Stainless steel construction, includes 36” of sealtite conduit and silicone seal. S316 316 Stainless steel construction, includes 36” of sealtite conduit and silicone seal. SS (shipped loose for field installation into heater) Silk screen to match acoustical ceiling tiles (specify style). PF-22 24 (610) 24 (610) 2 (1.0) PF-24 24 (610) 48 (1219) 4 (1.8) SPF-24(1) 24 (610) 48 (1219) 4 (1.8) PF-1448 14 (356) 48 (1219) 5 (2.3) PF-1460 14 (356) 60 (1524) 6 (2.7) H E A T E R S FCXX Flexible electrical conduit. Specify length of conduit XX-inches. Field-Installed Options R A D I A N T Radiant Ceiling Panels Filler Panel FP Sized and finished to match standard, custom color or silk screened panel. (1) Stainless steel frame, specify 304 or 316 type. Add finish code to end of catalog number. One time set-up fee if pattern is not in stock. Control Options Catalog Number Remote Room Thermostat – See page 98 Description SR-LV SmartRooms low voltage controller. Sensor(s) must be ordered at the same time. Requires connection to SmartRooms Communication Panel. PL-1 Plaster ring for SR-LV Controller BX-1 Box ring for SR-240/120 Controller Sensors Used with SR-240/120, 15’ long Longer length add per foot SRDP-10/10 SmartRooms Panel w/10comm. Ports and 10 ea. 20 amp relays SRDP-10/20 SmartRooms Panel w/10comm. Ports and 20 ea. 20 amp relays SRDP-20/20 SmartRooms Panel w/20comm. Ports and 20 ea. 20 amp relays 93 H E A T E R S AS Radiant Ceiling Panels Wire Suspended Flush Mounting Kit R A D I A N T FlushFlus Mount Frame h M ountFram e in Drywall Ceiling in Dryw all Ceili ng Nail Nail Ceiling Ceili ng Joist Jo ist Ceiling Joist Cei ling Joist Radiant Heater Radiant eat H er Each Kit Includes: Each Kit Includes: 22- Side Pieces - Side ieces P 22- End Pieces - End es Piec 44- Corner - Cor nerBrackets Br ackets Junction Juncti onBox Bo x 4”4" x 4”xx 4" 1-1/2” 1-1/2" Nai Naill 2”2" 2” Flush Flu shMounting Moun tingFrame ame Fr Factory Factor y Painted Pain ted24 24Gauge Gauge Extruded Extr udedAluminum Aluminum 2" 1-1/2” 1-1/2" Plaster Frame Pla ster rame F Flush Kit Flu shMount Moun t Kit Finished Ceiling Fin ished Ceiling Pow er Supply Suppl y Power Ceiling Jois t Ceiling Joist Each Kit Includes: : Each Kit Includes 2 - Side 2 Channels - Side hannels C - End Channels 2 - End2 Channels 4 CornerB rackets 4 - Corner Brackets with rews Sc with screws Ceilin g Ceiling 4" Toggl e Bol t Toggle Bolt CornerMoun tin g Corner Mounting Bracket withrews Sc 2" Bracket with Screws Surfa ce Mounting Fr am e Surface Mounting Frame Factory Pain ted 12 Gage Factory Painted 12 Gal vani zed Gage Steel Galvanized Steel 4” x 4” 4" xX1-1/2” 4" X 1-1/2" Junction ox B Junction Box Radia ntHeater Radiant Heater Surface Mountin g Surface Mounting 2”, 4 Lb4Density 2", Lb ensity D High Temperature Mineral High Temp erature ineral M Wool Woo lInsulation Insulation Support Clips Support lips C Reflectiv Reflective Foile Foi l High Density High Densit y Heating Panel Heating Panel 4”4" x 4”Xx 1-1/2” 4" X 1-1/2" Junction Juncti onBoxBo x With Cover with Co ver 2” 2" B Height 94 A Width Electric Heating Element Ele ctr ic Hea ting - Alloy Ele mentWire, -lloy ATefzel ire W, Insulation Tef zelInsulation 2222 Gauge Galvanized Gauge Galv anized Steel Front Steel ont Frandan dBack Back ofof UnitUnit Factory Finished Factor y Finished with with a High Temp Temperature, a High erature , Textured Powder Textured owder P Paint Pain t Finish Fin ish Cutaway View of View AS Seriesof Heater Cutaway AS S erieseat Her AS AS - Radiant Ceiling Panels Listing Watts Width In. (mm) Height In. (mm) Amps Weight lb (kg) Catalog Number 120 208 240 277 120 208 240 277 240 120 120 277 208 120 208 277 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 2.1 1.2 1.0 0.9 2.6 1.5 1.3 1.1 1.4 2.8 2.8 1.2 1.7 3.1 1.8 1.4 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) HX-AS2424-250-120 HX-AS2424-250-208 HX-AS2424-250-240 HX-AS2424-250-277 HX-AS2424-310-120 HX-AS2424-310-208 HX-AS2424-310-240 HX-AS2424-310-277 HX-AS2424-325-240 HX-AS2424-335-120 HX-AS2424-335-120 HX-AS2424-335-277 HX-AS2424-355-208 HX-AS2424-375-120 HX-AS2424-375-208 HX-AS2424-375-277 120 240 277 208 208 120 208 240 277 208 240 120 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 4.2 2.1 1.8 2.5 2.6 5.2 3.0 2.6 2.4 3.4 3.0 6.3 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) 30 (13.6) HX-AS2448-500-120 HX-AS2448-500-240 HX-AS2448-500-277 HX-AS2448-515-208 HX-AS2448-535-208 HX-AS2448-625-120 HX-AS2448-625-208 HX-AS2448-625-240 HX-AS2448-675-277 HX-AS2448-715-208 HX-AS2448-725-240 HX-AS2448-750-120 240 120 277 208 208 240 277 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 1.3 2.9 1.3 1.9 2.1 1.8 1.6 18 (8.2) 18 (8.2) 18 (8.2) 18 (8.2) 18 (8.2) 18 (8.2) 18 (8.2) HX-AS1448-300-240 HX-AS1448-350-120 HX-AS1448-350-277 HX-AS1448-400-208 HX-AS1448-435-208 HX-AS1448-435-240 HX-AS1448-435-277 120 240 277 208 277 240 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 60 (1524) 60 (1524) 60 (1524) 60 (1524) 60 (1524) 60 (1524) 2.9 1.6 1.4 2.2 1.9 2.3 22 (10.0) 22 (10.0) 22 (10.0) 22 (10.0) 22 (10.0) 22 (10.0) HX-AS1460-350-120 HX-AS1460-375-240 HX-AS1460-375-277 HX-AS1460-450-208 HX-AS1460-535-277 HX-AS1460-550-240 H E A T E R S 24 x 24 250 250 250 250 310 310 310 310 325 335 335 335 355 375 375 375 24 x 48 500 500 500 515 535 625 625 625 675 715 725 750 14 x 48 300 350 350 400 435 435 435 14 x 60 350 375 375 450 535 550 Volts (1 Phase) R A D I A N T Radiant Ceiling Panels Add finish code to end of catalog number. See page 93. 95 H E A T E R S Cove R A D I A N T Cove Heater Applications •Classrooms •Lobbies •Garages •Offices • Hospital Rooms •Restrooms Cove heaters are designed to supply efficient radiant heat. They provide greater comfort at lower temperature settings and can be set up for individual or zone control to reduce energy costs. • Radiant Heat: Radiant energy travels in a straight line from the heater to people and objects in the room, warming the space. • Convection Flow: The design of the heater provides a convection flow from behind and over the top of the unit to circulate warm air into the room. • Virtually Maintenance Free: No moving parts to replace or service. • Exclusive Tilt and Lock Mounting System: Allows easy, one-person installation. Standard Construction Features Heating Element – Commercial grade tubular heating ele- Installation Requirements – Minimum clearances: Six ment. feet from the floor; 2-1/2 inches from plaster ceilings or 4-1/2 inches from false ceilings, vinyl ceilings and plaster moldings. Housing – Heater has an 18-gauge G-90 galvanized steel frame. The continuous single-piece construction and solid metal end caps provide durability. Front Panel – Heavy gauge aluminum front panel finished with an off-white high emissivity coating. Other standard finishes include walnut, sandalwood, light almond and pure white. Electrical – Ventilated junction boxes at each end of the heater with one-half inch electrical knockouts. High temperature (125°C) 12-gauge cross link wiring is used through out the heater. 96 Maintain one inch below heater and any fabric. Allow one-inch clearance between adjacent heaters. COVE Standard Finishes Finish Availability Off-White OW Standard Walnut WL Stock Sandalwood SW Stock Light Almond AL Stock Pure White PW Stock H E A T E R S Code R A D I A N T Cove Heater To Specify Finish: Choose code from above. Example: C-4524-OW = Off-White Unit Remote Room Thermostat – See page 98 Cove Heater Listing Watts 450 600 750 900 1050 1200 1500 1800 2000 Volts (1 Phase) Amps Length In. (mm) 120 208 240 277 120 208 240 277 120 208 240 277 120 208 240 277 120 208 240 277 120 208 240 277 208 240 277 208 240 277 208 240 277 3.7 2.2 1.9 1.6 5 2.9 2.5 2.2 6.2 3.6 3.1 2.7 7.5 1.3 3.7 3.2 8.8 5 4.4 3.8 10 5.8 5 4.3 7.2 6.2 5.4 8.7 7.5 6.5 9.6 8.3 7.2 34 (864) 34 (864) 34 (864) 34 (864) 47 (1194) 47 (1194) 47 (1194) 47 (1194) 59 (1499) 59 (1499) 59 (1499) 59 (1499) 71 (1803) 71 (1803) 71 (1803) 71 (1803) 83 (2108) 83 (2108) 83 (2108) 83 (2108) 94 (2388) 94 (2388) 94 (2388) 94 (2388) 106-1/4 (2699) 106-1/4 (2699) 106-1/4 (2699) 118-1/4 (3004) 118-1/4 (3004) 118-1/4 (3004) 132 (3353) 132 (3353) 132 (3353) Add finish code to end of catalog number. Weight lb (kg) 6 (2.7) 6 (2.7) 6 (2.7) 6 (2.7) 8 (3.6) 8 (3.6) 8 (3.6) 8 (3.6) 10 (4.5) 10 (4.5) 10 (4.5) 10 (4.5) 12 (5.4) 12 (5.4) 12 (5.4) 12 (5.4) 13 (5.9) 13 (5.9) 13 (5.9) 13 (5.9) 15 (6.8) 15 (6.8) 15 (6.8) 15 (6.8) 18 (8.2) 18 (8.2) 18 (8.2) 20 (9.1) 20 (9.1) 20 (9.1) 22 (10) 22 (10) 22 (10) Catalog Number HX-C-4512 HX-C-4508 HX-C-4524 HX-C-4527 HX-C-6012 HX-C-6008 HX-C-6024 HX-C-6027 HX-C-7512 HX-C-7508 HX-C-7524 HX-C-7527 HX-C-9012 HX-C-9008 HX-C-9024 HX-C-9027 HX-C-10512 HX-C-10508 HX-C-10524 HX-C-10527 HX-C-12012 HX-C-12008 HX-C-12024 HX-C-12027 HX-C-15008 HX-C-15024 HX-C-15027 HX-C-18008 HX-C-18024 HX-C-18027 HX-C-20008 HX-C-20024 HX-C-20027 97 T H E R M O S T A T S THERMOSTATS 1006998 901-1006998 901-1007030 1007030 901-OTH550BL 901-OTH507 901-OTH660 901-OTH607 901-1016941 1004328 901-124644 901-OTH800D 901-OTH824 901-124645 901-RC840 901-RC840T-240 901-RC840T-277 1007002 901-124640 901-124641 SR-240/120(4) 901-RT850 901-RT850T-240 1007014 901-124642 901-124643 Line Voltage Thermostats for 240 Series Heaters (Pages 29-32) Catalog Number Switch Type Color Type 1007014 Bimetal White SPDT Tamper- Thermo- Amps @ Amps @ proof meter 120-240V 277V No No 22 19 Pilot Duty Positive Temperature Off Range °F — — 40-80 Low Voltage Thermostats for Industrial Unit Heater 238 Series (Pages 26-28) 1006998 Bimetal White SPDT No No — — 30VA at 30V max Yes 50-90 1007030 2-stage Bimetal White 2 SPST Switches No Yes — — 30VA at 30V max Yes 40-90 — — 41-95 — No 40-85 — Yes 40-85 Thermostats for AS Series Radiant Ceiling Panels (Pages 92-95) SR-240/120(4) Electronic R-101 R-102 Bimetal White Beige DPDT No Digital SPST No No DPST No No 16A @ 120&240V — 22 18 (4) A 3 inch deep double electrical box will be supplied for wall installation. Remote window sensor option is available, contact factory for pricing. Thermostats for Cove Heaters (Pages 96-97) R-101 R-102 Bimetal Beige SPST No No DPST No No 22 18 — No 40-85 — Yes 40-85 Explosion-proof Heaters - Remote Wall Mounted Thermostat (Pages 8-21) Catalog Number Switch Type Ratings Type 1007002 Bimetal Class I, Div 1 Group C&D, Class II, Div 1 Group E,F&G NEMA 7 SPDT Tamper- Thermo- Amps @ proof meter 125-277V No No 22 Pilot Duty Temperature Range °F (°C) — 50-90 (10-32) Washdown/Corrosion Resistant 234 Series Unit Heater Remote Wall Mounted Thermostat (Pages 23-25) 98 Catalog Number Switch Type Ratings Type Tamperproof Thermometer Amps Pilot Duty Temperature Range °F (°C) 1004328 Bulb NEMA 4X SPDT No No 25A @ 120-240V 22A @ 277V 125VA 40-110F (4-43) THERMOSTATS Catalog Number Switch Type Color Type 901-124640 901-124642 901-124643 Bimetal Beige Bimetal White SPST SPST DPST 901-OTH800D(1) White 901-OTH550(1)(3) (3) Electronic 901-OTH507(1) White 901-OTH660(2)(3) (3) Tamper- Thermo- Amps @ Amps @ Pilot Positive proof meter 120-240V 277V Duty Off No No 22 19 — ­­ No No 22 19 — 15A @ 208&240 — — 16 — — — 16 — DPST Pulse Yes Digital 16 Pulse or White On-Off 901-OTH607(2) No No Yes No Temperature Range oF 40-80 40-80 40-85 T H E R M O S T A T S Line Voltage Thermostats for 900 Series Heaters (Pages 39-91) — — 16 — (1) Do not use these thermostats with heaters that have inductive loads (heaters that have a motor or contactor). (2) Programmable electronic thermostat. Recommended for heaters with motor or contactor. (3) Add to catalog number W - white or A - almond color. Low Voltage Thermostats for 900 Series Heaters (Pages 33-91) Catalog Number Switch Type Tamper- Thermo- Amps @ Amps @ proof meter 120-240V 277V Pilot Duty Positive Off Temperature Range oF — 30VA at 30V max Yes 50-90 — — 36VA at 30V max No 45-95 — — 30VA at 30V max Yes 40-90 Color Type 901-1006998 Bimetal White SPST No No — 901-219981 Precision Snap White Action SPST No No No Yes 901-1007030 (3) 2-stage 2 SPST White Bimetal Switches (3) 2-Stage room thermostat for use with 922 Series Cabinet Unit Heater. Low Voltage Electronic Thermostats for 900 Series Heaters (Pages 69-91) Catalog Number Switch Type Tamper- Thermo- Amps @ proof meter 120-240V Amps @ 277V Color Type 901-1016941 Electronic Beige DC Pulse No No — — 901-OTH824 Electronic White Pulse Yes Digital — — Output Positive Temperature Signal Off Range oF 20mA Max at 8 VDC 24VAC No 50-90 No 40-85 Amps@ 120-240V Amps@ 277V Input Signal 23 23 23 22 22 — — 18 — 18 (1) Do not use these thermostats with heaters that have inductive loads (heaters that have a motor or contactor). Controllers and Accessories for 900 Series Heaters (Pages 33-91) Catalog Number Description Triac Relay without transformer (pulsing) 120/208/240/277 V 901-RT850T-240 Triac Relay with transformer 208/240 V 901-RC840 On-Off Relay without transformer 120/208/240/277 V 901-RC840T-240 On-Off Relay with transformer 208/240 V 901-RC840T-277 On-Off Relay with transformer 277 V 901-RT850 24VAC & 4-32 VDC 24 VAC — — — Accessories for 900 Series Heaters (Pages 33-91) Catalog Number Description 901-124644 UniversalThermostatGuard.Protectsbothlineandlowvoltagethermostatsagainstvandalism,damage,and unauthorized adjustment of thermostat settings. 99 W A R R A N T Y L I M I T E D Limited Warranty HEATREX new products are warranted against defects in workmanship, material, design, labeling and packaging. No other warranty, expressed or implied, written or oral, applies. No person other than an officer or the general manager of HEATREX is authorized to give any other warranty or assume any liability. Warranty Period This warranty is effective for eighteen months from the date of shipment of the product from HEATREX’s factory, or for twelve months from the date the product is first placed into service, whichever period lapses first. Conditions of Warranty HEATREX products must be installed, operated, and maintained in accordance with HEATREX’s instructions. HEATREX is not liable for damage or unsatisfactory performance of the product resulting from accident, negligence, alteration, unauthorized repair, improper application or installation of the product, improper specifications, or corrosion. HEATREX IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Claims against carriers for damage in transit must be filed by the purchaser with the carrier. Remedy Contact the HEATREX sales department in St. Louis at (314) 333-5500, for a Return Material Authorization Number (RMA#). Return the part or product in question, freight prepaid, and marked with your company name and the RMA# to: HEATREX 425 Hanley Industrial Court St. Louis, MO 63144 Attn: Return Materials Manager If after receipt of the product and the claim, HEATREX finds to its reasonable satisfaction that the product is defective in workmanship, material, design, labeling or packaging, the product will be repaired or replaced, or the purchase price refunded at HEATREX’s option. There will be no charge to the purchaser for parts or labor. Removal and reinstallation of the product, and shipment of the product to HEATREX for repair or inspection, shall be at the purchaser’s risk and expense. THE REPAIR, REPLACEMENT, OR REFUND PROVIDED FOR IN THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE TERMS OF THIS LIMITED WARRANTY. 100 INTRODUCTION HEATREX offers commercial and industrial electric heating and control systems that set the industry standard for excellence. The company’s heating solutions reflect more than 80 years of innovation, product quality and efficient service. This catalog features HEATREX’s complete Space Heating line. Our products include Explosion-proof an explosion-proof convector; the Washdown/Corrosion Resistant Unit Heater; and several types of standard unit heaters. HEATREX’s line of Comfort Heating Products cover a wide range of commercial and industrial applications. Whether the requirement is for architectural wall heaters, cabinet unit heaters, convector heaters or ceiling heaters, HEATREX has a product to match the application. HEATREX’s quality is matched only by its customer service and support. With its quick-ship delivery program, HEATREX provides the products you need. Color Selection Chart Standard Colors 900 Series White (W) Standard Color 240 Series Almond (A) Special Colors 900 Series Camel Optional Colors 240 Series Metallic Silver (AE) Beige-Grey (BG) Grey Yellow Metallic Charcoal (CM) Bronze (BZ) Red White Textured Black (NR) Aluminum (AL) Blue Textured Beige Refer to catalog listings for standard and special color availability. Use color codes in parentheses when specifying and ordering. Custom colors are also available on 900 Series. Special and Optional Colors subject to setup charges. Colors represented are approximate. electric heating products explosion-proof unit heater wall heater ceiling heater explosion-proof convector washdown/corrosion resistant unit heater industrial unit heater unit heater convector heater cabinet heater baseboard heater wall heater radiant panel commercial & industrial For Limited Warranty Information contact: HEATREX 425 HANLEY INDUSTRIAL COURT ST. LOUIS, MO 63144 314-333-5500 www.heatrex.com 90-1000-80-1 5M0610 electric heating and controls