GRX-IRPS-WH GRAFIK Systems Accessories irps-1 1.7.08 GRX-IRPS-WH Infrared Transmitter/Receiver Pair Description Infrared transmitter/receiver pair detects partition movement and, in conjunction with other Lutron products, coordinates lighting preset functions in areas such as partitioned meeting rooms or ballrooms. Sensors may be used with GRAFIK Eye 3000 or 4000 Systems, GRAFIK Eye QS, as well as GRAFIK 5000/6000®/7000 Systems. • Automatically combines lighting preset functions when partition is open creating one large space. • Lighting preset functions become independent as partition is closed creating several smaller spaces. • Sensors require additional Lutron interface (GRX-IO or OMX-IO) and power supply (GRX-12VDC) for proper operation with GRAFIK Eye 3000/4000 system. • Sensors also work with a GRAFIK Eye QS system, with a QSWS2-2B wallstation and power supply. • Sensors function with SeeTouch SO series wallstation with occupant sensor connection if used with GRAFIK 5000/6000/7000 system. One SO series wallstation with occupant sensor connection (ordered separately) can accommodate and supply power for one transmitter/receiver pair for one moveable wall. This will count as two devices on the link. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 1 GRX-IRPS-WH GRAFIK Systems Accessories irps-2 1.7.08 System Diagram: GRAFIK Eye 3000 and 4000 Systems GRAFIK 5000/6000/7000 Systems Ceiling GRX-IRPS Transmitter (TX) GRX-IRPS Receiver (RX) Room A Room B Partition V R V MUX MUX COM V+ CCO 2 NO CCO 2 NC 1-2 COM CCO 1 NO CCO 1 NC CCO 4 NO CCO 4 NC 3-4 COM CCO 3 NO CCO 3 NC 5 COM CCO 5 NO CCO 5 NC Wallstations 3 4 0-24 V 0-24 V P/N 500-1072 COM CCI 5 CCI 4 CCI 3 CCI 2 CCI 1 1 2 GRX-12VDC R 1A ½A GRX-IO 24 V 200 mA 800.523.9466 Wallstations +1.610.282.3800 LUTR ON STAT CCO 1 CCO 2 CCO 3 CCO 4 CCO 5 www.lutron.com PGM O N 1 2 34 56 78 LUTR ON GRX/OMX-IO PELV (Class 2: USA) Control Link System Diagram: GRAFIK 5000/6000/7000 Systems Ceiling GRX-IRPS Transmitter (TX) GRX-IRPS Receiver (RX) Room A Room B Partition GRX-12VDC Note: Power supply not needed if using SO model wallstation with occupant sensor connection Wallstations Wallstations LUTR ON LUTR ON SeeTouch wallstation R PELV (Class 2: USA) control link S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 2 GRX-IRPS-WH GRAFIK Systems Accessories irps-3 1.7.08 System Diagram: GRAFIK Eye QS System Ceiling GRX-IRPS Transmitter GRX-IRPS Receiver Room A Room B Partition QSWS2-2B wallstation GRX-12VDC To CCI1 Wallstation GRAFIK Eye QS GRAFIK Eye QS LUTRON Wallstation LUTRON PELV (Class 2: USA) Control Link R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 3 GRAFIK Systems GRX-IRPS-WH Accessories irps-4 1.7.08 Specifications Power • Operating voltage: Low-voltage PELV (Class 2: USA) 12 - 24 V from GRX-12VDC plug-in power supply (ordered separately). One GRX-12VDC can supply power to five sensor transmitter/receiver pairs. • Transmitter and receiver have reverse polarity and short-circuit protection. Sensor Status Indicator • Receiver includes an LED indicator that assists in sensor alignment during installation and provides sensor operating status. System Capacity • Each GRX-IO or OMX-IO Interface (ordered separately) can accommodate up to five transmitter/receiver pairs for five different moveable walls. • Each QSWS2-2B wallstation (ordered separately) can accommodate one transmitter/receiver pair for one moveable wall. Connection Wire leads provided. Finish • White painted plastic. Environment 32 - 104 °F (0 - 40 °C). Relative humidity less than 90% noncondensing. Mounting Surface mount indoors only. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 4 GRX-IRPS-WH GRAFIK Systems Accessories irps-5 1.7.08 Dimensions and Mounting • Receiver and transmitter surface mount in 1-gang U.S. wallboxes 3.5 in. (89 mm) deep, mounted facedown from the ceiling. Indoors only. • The sensors must be mounted in a position where the partition separates the transmitter and receiver when the partition is closed. • Transmitter and receiver may be located no more than 8 ft. (243 mm) apart. • Adjustable mounting brackets allow easy alignment during installation. • Wires feed through the back of the transmitter/receiver. Side View Standard single-gang U.S. wallbox mounted facedown and flush with ceiling surface (typical of two). Ceiling 1.5 in. (38 mm) GRX-IRPS-WH Receiver GRX-IRPS-WH Transmitter Partition 8 ft. (243 mm) maximum) Top View Single gang wallbox (typical of two) Wallbox mounting line of center R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 5