Installation Guide GE Lighting Lumination LED Luminaire TM TSMTL Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK • Turn power off before inspection, installation or removal. • Properly ground electrical enclosure. RISK OF FIRE • Follow all NEC and local codes. • Use only UL or IEC approved wire for input/output connections. Minimum size 18 AWG (0.75mm2). RISQUES DE DÉCHARGES ÉLECTRIQUES • Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire. • Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique. RISQUES D’INCENDIE • Respectez tous les codes NEC et codes locaux. • N’utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.75mm2). Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Prepare Electrical Wiring Electrical Requirements • The LED luminaire must be connected to the mains supply according to its ratings on the product label. Grounding Instructions • The grounding and bonding of the overall system shall be done in accordance to local electric code of the country where the luminaire is installed. imagination at work Unit Installation Note: Steps 1 through 4 should be completed before the dry-wall has been installed. Option A Option B T-grid 1 Slide hanger bars through adjustable mounting brackets. 2 Option A: Mount fixture by attaching hanger bars to T-grid ceiling (BH3 SKU 94890). Option B: Mount fixture with 1/2” EMT conduit and clips (not supplied). NOTE: Per local building codes, attach safety cables to seismic tabs located on each corner on top of the fixture. 3 6 If necessary, adjust the height of the mounting brackets by loosening the nut so that the bottom of the fixture is flush with the bottom of the ceiling tile. It is recommended that the operator use a wrench to tighten nut. Finish the ceiling, taping and mudding around the fixture to the lip for a clean, finished edge. 4 See the Wiring Instructions on the next page and complete the necessary wiring connections. 5 Install dry-wall ceiling tile with the appropriately sized hole cut out for the fixture (see table below). Fixture Hole Size TSMTL-2 14.17 in. x 9.34 in. (359.86 mm x 237.28 mm) TSMTL-3 19.17 in. x 9.34 in. (486.86 mm x 237.28 mm) Wiring Instructions 1 Remove the cover plate with knockouts from the top of the fixture by removing its screws. 2 Remove one or both knockouts from the plate as desired, and secure the conduit or cable supplying the power to the plate. 3 Connect the supply line to the black (hot), white (neutral/common), and green (ground) leads. Optional: If using a dimming controller, connect matching-colored wires together (violet and gray leads). Risk of damage: Make sure that supply connection, light fixture wiring, and dimming cables are connected to proper driver inputs. Wrong connection may cause damage to the product. Must use UL approved conduit fittings for all enclosure box connections to prevent wire cuts by sharp edges and excessive strain on wiring. 4 Carefully fold the wires into the fixture while replacing the cover plate and screwing it back down. Optional Installation: 0-10 Volt Dimming Lighting Controller 1-10V wiring diagram Line (black) Neutral (white) Ground (green) (1-10) + (violet) (1-10) - (gray) 5 Line Neutral Ground DRIVER (0-10V) (0-10V) + At output side of LED driver, make appropriate connections using twist-on wire connectors. Follow lighting controller installation instructions. Troubleshooting Note: For a replacement driver, please contact GE Lighting and request the following driver: 50W Class 1 CC Lightech Driver (GELD50MV700PVNA). Through Wiring Catalogue No. Maximum number of fixtures TSM-S/R-3-L1 & TSMTL-S/R-3-L1 40 TSM-S/R-3-L2 & TSMTL-S/R-3-L2 30 TSM-S/R-2-L1 & TSMTL-S/R-2-L1 60 TSM-S/R-2-L2 & TSMTL-S/R-2-L2 40 Calculations assume use with a 15A circuit (80% loading) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme á la NMB-003 du Canada. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Fixture intended for commercial use only. Use only in non-insulated applications. GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo and Lumination are trademarks of the General Electric Company. © 2015 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. IND128-011915