Cooper Wiring Devices

advertisement
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
!
en
Alw
ay
s
n!
Al
nglig - Alltid ö
pp
tillgä
e
ltid
www.chscontrols.se
so
availa
ble - Alway
p
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
We offer a complete line of wiring
devices according to North American Standard from Cooper Wiring
Devices.
The product line consists of receptacles,
inlets, plugs, connectors and corresponding
device boxes and covers. The pin configuration meets the configurations specified by
ANSI/NEMA and CSA. The majority of the
products is UL and CSA approved and meet
Federal Specification WC596-F.
1
2
3
Device Boxes
1. Device box with knockouts
2. Splashproof device box, made of aluminium
3. Splashproof device box, made of fiberglass
TEST
RESET
10
9
4
5
6
7
8
14
11
12
13
15
Switches, receptacles, Inlets
4. Switches
5. Single phase double receptacle
6. Single phase double receptacle with eart fault protection
7. Single phase double receptacle with surge protection
8. Modular jacks
9. Three phase single receptacle
10. Single phase and three phase inlets
Cover Plates
11. Cover plate for switches
12. Cover plate for double receptacle
13 Splashproof cover plate for switches
14. Splashproof cover plate for double receptacle
15. Splashproof cover plate for single receptacle and
inlet
Switches see notes 1, 2
23
33
103
Technical Data
56
83
Temperature range
Wire range
Weight
Approvals
-20 - +60°C
AWG14 -10
55 g
UL, CSA
Three way
Dimensions in mm
Type
Rated
voltage, V
Current
A
Catalogue numbers
Single pole
Double pole
Commercial Grade
Commercial Grade
Specifiers Grade
Specifiers Grade
3 position momentary see note 2
120-277
120-277
120-277
120-277
125-250
15
20
15
20
10/5
IUS15SP
IUS20SP
IUS15SPSG
IUS20SPSG
IUS10SPM
IUS15DP
IUS20DP
IUS15DPSG
IUS20DPSG
IUS10DPM
Notes
1 Switches and receptacles are brown. For white units, add W last in the catalogue number. Example: IU2515R will be IU2515RW
2 Momentary, spring return to centre position - off position
3 The designation refers to receptacle, see page 8 for configurations
2
IUS153W
IUS203W
IUS153WSG
IUS203WSG
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
Single Phase Devices, Straight Blade Type, 15 -20 A see note 1, 3, 4, 5, 6, 7, 8
Technical Data
103
65
70
83
44
46
Temperature range
Wire range
Weight, double receptacle
Weight, inlet
Approvals
24
Dimensions in mm
Type
Rated
voltage, V
Current Designation to
A
NEMA/CSA
Catalogue number
D. receptacle Inlet,fl.
2 pole + earth, Commercial Grade
2 pole + earth, Specifiers Grade
2 pole + earth, Hospital Grade
2 pole + earth, surface mount
2 pole + earth, Commercial Grade
125
125
125
125
125
15
15
15
15
20
5-15R
5-15R
5-15R
5-15R
5-20R see note 9
IU2515R
IU2515RSG
IU2515RHG
IU2515RSM
IU2520R
2 pole + earth, Specifiers Grade
2 pole + earth, Hospital Grade
2 pole + earth, Specifiers Grade
2 pole + earth, Hospital Grade
2 pole + earth, Specifiers Grade
125
125
250
250
250
20
20
15
15
20
5-20R see note 9
5-20R see note 9
6-15R
6-15R
6-20R see note 9
IU2520RSG
IU2520RHG
IU2615RSG
IU2615RHG
IU2620RSG
2 pole + earth, Hospital Grade
250
20
6-20R see note 9
IU2620RHG
35
-20 - +60°C
AWG 14-10
90 g
110 g
UL, CSA
Plug
Connector
IU515I
IU515P
IU515PHG
IU515C
IU515CHG
IU520I
IU520P
IU520PHG
IU615P
IU615PHG
IU620P
IU520C
IU520CHG
IU615C
IU615I
IU620I
IU620C
IU620PHG
Single Phase Receptacle, Earth Fault Protection, Straight Blade Device, 15 - 20 A see notes 1, 3, 4, 10
43
Technical Data
103
83
67
Temperature range
Frequency
Class according to NEC
Sensitivity
-35 - +66°C
60 Hz
Class A, personal prot.
4-6 mA, UL curve
Wire range
Weight
Approvals
AWG 14-12
168 g
UL, CSA only 15 A
29
Dimensions in mm
Type
Rated
voltage, V
Current Designation to
A
NEMA/CSA
Catalogue numbers
Double receptacle with brown cover plate
2 pole + earth
2 pole + earth, Hospital Grade
2 pole + earth
2 pole + earth, Hospital Grade
120
120
120
120
15
15
20
20
IU2515RG
IU2515RGHG
IU2520RG
IU2520RGHG
33
5-15R
5-15R
5-20R
5-20R
Notes
4 Commercial Grade - standard
Specifiers Grade - Industrial use
Hospital Grade - UL/CSA approved for hospital use
5 Contact CHS Controls for receptacles with insulated earth
6 Contact CHS Controls for weights and dimensions for plugs and connectors
7 Surface mount receptacle, Height 94 mm, width 49 mm, depth 27 mm, weight 100 g
8 Plugs and connectors for outdoor use, ingress protection NEMA 3R/4X/6, IP 66, add WP at the end of the catalogue number. Example: IU515P will be IU515PWP
9 Receptacle type 5-20R and 6-20R are available as NEMA or as CSA. For CSA version add CSA at the end of the catalogue number. Example: IU2520R will be
IU2520RCSA
10 A receptacle with earth fault protection will also protect downstream standard receptacles. Contact CHS Controls for wiring diagrams
3
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
Single Phase Receptacle, Surge Protection, Straight Blade Device, 15 - 20 A see notes 3, 4, 5, 11
Technical Data
43
103
83
Temperature range
Surge protection level, UL
Peak surge current
Response time
Wire range
Weight
Approvals
67
-35 - +66°C
500 V
13 kA
< 5 ns
AWG 14-12
168 g
UL, CSA only 15 A
29
Dimensions in mm
Type
Rated
voltage, V
Current Designation to
A
NEMA/CSA
Catalogue numbers
Double receptacle with blue plastic cover plate
2 pole + earth
2 pole + earth, Hospital Grade
2 pole + earth
2 pole + earth, Hospital Grade
120
120
120
120
15
15
20
20
IU2515RM
IU2515RMHG
IU2520RM
IU2520RMHG
33
5-15R
5-15R
5-20R
5-20R
Modular Jack for Phone and Data
Technical Data
70
114
Temperature range
Standard, category 3
Standard, category 5
Punch down tool
Weight, jack outlet
Weight, modular jack
Approvals
83
-20 - +70°C
T568B
T568A
Not required
40 g
5g
UL, CSA
Dimensions in mm
Description
Catalogue number
Jack outlet/cover plate for 1 modular jack, to be installed in std outlet box, white
Jack outlet/cover plate for 2 modular jack, to be installed in std outlet box, white
RJ45 modular jack, category 3 for phone, AT&T standard T568B connected
RJ45 modular jack, category 5 for data communication, T568A connected
IUMJH
IUMJ2H
IUMJKAT3
IUMJKAT5
Single Phase and Three Phase Receptacle, Straight Blade Device, 30 - 60 A see notes 3, 6, 12
Technical Data
94
Temperature range
Wire area
Weight
Approvals
83
43
46
70
-40 - +60°C
AWG 12-4
180 g
UL, CSA
54
Dimensions in mm
Notes
3 The designation refers to receptacle, see page 8 for configurations
4 Commercial Grade - standard
Specifiers Grade - Industrial use
5 Contact CHS Controls for receptacles with insulated earth
4
Hospital Grade - UL/CSA approved for hospital use
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
Type
Rated
Voltage, V
Current Designation to
A
NEMA/CSA
Catalogue numbers
Single receptacle
Plug
2 pole + neutral + earth
2 pole + neutral + earth
2 pole + neutral + earth
3 pole + earth
3 pole + earth
125-250
125-250
125-250
250
250
30
50
60
30
50
14-30R
14-50R
14-60R
15-30R
15-50R
IU1430R
IU1450R
IU1460R
IU1530R
IU1550R
IU1430P
IU1450P
IU1460P
IU1530P
IU1550P
3 pole + earth
250
60
15-60R
IU1560R
IU1560P
Single Phase and Three Phase Locking Device, 15 - 30 A see notes 3, 6, 8, 12, 13
Max
41
83
Tehnical Data
Dimensions in mm
20
Max 67
65/78
44/56
46/56
Temperature range
Wire range, 15 A
Wire range, 20-30 A
Weight, receptacle
Weight, inlet
Approvals
AWG 14-10
AWG 14-8
130
100
UL, CSA
Type
Rated
voltage, V
Current Designation to
A
NEMA/CSA
Catalogue numbers
Receptacle Inlet, flange Plug
Connector
2 pole + earth
2 pole + earth
2 pole + earth
2 pole + earth
2 pole + earth
125
125
125
250
250
15
20
30
15
20
L5-15R
L5-20R
L5-30R
L6-15R
L6-20R
IUL515R
IUL520R
IUL530R
IUL615R
IUL620R
IUL515I
IUL520I
IUL530I
IUL615I
IUL620I
IUL515P
IUL520P
IUL530P
IUL615P
IUL620P
IUL515C
IUL520C
IUL530C
IUL615C
IUL620C
2 pole + earth
2 pole + earth
2 pole + earth
2 pole + earth
2 pole + neutral + earth
250
277
277
277
125-250
30
15
20
30
20
L6-30R
L7-15R
L7-20R
L7-30R
L14-20R
IUL630R
IUL715R
IUL720R
IUL730R
IUL1420R
IUL630I
IUL715I
IUL720I
IUL730I
IUL1420I
IUL630P
IUL715P
IUL720P
IUL730P
IUL1420P
IUL630C
IUL715C
IUL720C
IUL730C
IUL1420C
2 pole + neutral + earth
3 pole + earth
3 pole + earth
3 pole + earth
3 pole + earth
125-250
250
250
480
480
30
20
30
20
30
L14-30R
L15-20R
L15-30R
L16-20R
L16-30R
IUL1430R
IUL1520R
IUL1530R
IUL1620R
IUL1630R
IUL1430I
IUL1520I
IUL1530I
IUL1620I
IUL1630I
IUL1430P
IUL1520P
IUL1530P
IUL1620P
IUL1630P
IUL1430C
IUL1520C
IUL1530C
IUL1620C
IUL1630C
3 pole + earth
3 pole + neutral + earth
3 pole + neutral + earth
3 pole + neutral + earth
3 pole + neutral + earth
600
120/208
120/208
277/480
277/480
30
20
30
20
30
L17-30R
L21-20R
L21-30R
L22-20R
L22-30R
IUL1730R
IUL2120R
IUL2130R
IUL2220R
IUL2230R
IUL1730I
IUL2120I
IUL2130I
IUL2220I
IUL2230I
IUL1730P
IUL2120P
IUL2130P
IUL2220P
IUL2230P
IUL1730C
IUL2120C
IUL2130C
IUL2220C
IUL2230C
3 pole + neutral + earth
3 pole + neutral + earth
347/600
347/600
20
30
L23-20R
L23-30R
IUL2320R
IUL2330R
IUL2320I
IUL2330I
IUL2320P
IUL2330P
IUL2320C
IUL2330C
Notes
6 Contact CHS Controls for weights and dimensions for plugs and connectors
8 Plugs and connectors for outdoor use, ingress protection NEMA 3R/4X/6, IP 66, add WP at the end of the catalogue number. Example: IU515P will be IU515PWP
11 The receptacle is blue, blue plastic cover plate included. For white receptacle, add W at the end of the catalogue number. Example: IU2515RM will be IU2515RMW
12 Contact CHS Controls for other voltages and currents
13 Receptacles can also be supplied with flange, same dimensions as for inlet. For receptacle with flange, add F at the end of the catalogue number. Example: IUL1420R
will be IUL1420RF
14 Dimensions for inlet, first dimension applies for 15 A devices, second for 20-30 A devices
5
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
Outlet Boxes see notes 15, 16 ,17 ,18, 19
IUTP594
IUTP7014
IU6080
Description
Catalogue
number
Dimensions, mm
Height Width Depth
Weight
g
Steel box with 1/2” knockouts, UL approved
Splashproof box, aluminium, 1/2” NPT thread, c-UL approved
Splashproof box, black fiberglass, 3/4” NPT thread, UL approved
IUTP594
IUTP7014
IU6080
101
116
116
220
240
275
55
71
71
47
51
64
Standard Cover Plates
For switch
For double receptacle
For device, UL and CSA approved
For double receptacle,
earth fault/surge protection
For single receptacle
Catalogue numbers
Plastic
Stainless steel
Brown
unpainted
Dimensions, mm Weight
Height Width
g
Blank cover
Switch
Double receptacle
Double receptacle with earth fault protection
Double receptacle with surge protection
Three phase receptacle, straight blade device
IUWP1G
IUWP1GSW
IUWP1G2R
IUWP1GGF
IUWP1GGF
IUWP1GSS
IUWP1GSWSS
IUWP1G2RSS
IUWP1GGFSS
IUWP1GGFSS
IUWP1GTSBDSS
114
114
114
114
114
114
70
70
70
70
70
70
46
46
46
46
46
46
Receptacle, locking device, 15 A
Receptacle, locking device, 20-30 A
IUWP1G15LT
IUWP1G30LT
IUWP1G15LTPSS
IUWP1G30LTPSS
114
114
70
70
46
46
Notes
15 Splashproof boxes and covers meet NEMA 3R, IP54
16 Use IUTP6080 for three phase receptacles, straight blade type
17 Contact CHS Controls for cable connectors, flexible conduit connectors and hubs with NPT thread
18 IUTP7010 has 3 conduit entries, 2 plugs are included. Contact CHS Controls for outlet boxes with alternative conduit entries
19 IU6080 has 2 conduit entries, sealed when supplied
20 Splashproof covers are to be used with splashproof boxes. They can also be used with box type IUTP594 (eg for installation in walls) by using adaptor plate IU7349, to
be ordered separately
21 Contact CHS Controls for cover plates made of aluminium
22 Meets National Electrical Code 2002 article 406-8 (b), for receptacles installed outdoors both receptacle and plug shall be protected
23 Depth is only valid for in-use cover plates, In-use cover plates weight ca 300 g
24 Splashproof cover plates for double receptacle and receptacle with earth fault/surge protection for vertical installation, add V last in the catalogue number.
Example: IUWC1G2R will be IUWC1G2RV
25 Covers to be used with box IUTP7010
26 The switch operator can be padlocked, comply with OSHA lockout/tagout requirements
27 The enclosure is equipped with 3/4” conduit entry.
6
Cooper Wiring Devices
Wiring Devices according to NEMA/CSA
Splashproof Cover Plates see notes 15, 20, 21, 22, 23, 24
For double receptacle
horizontal installation
for double receptacle
earth fault/surge protection
horizontal installation
For device, UL/CSA alt. c-UL approved
Blank cover, die cast
Double receptacle, die-cast
Double receptacle, earth fault protection, die-cast
Double receptacle, earth fault protection, die-cast
Single phase inlet, straight blade device
For single receptacle, inlet
For double receptacle, with in-use cover
Catalogue number
Standard
With
type
In-use cover
Inlet
Plastic
Dimensions, mm
Height Width Depth
Weight
g
IUWC1GI15
72
72
72
72
116
116
116
116
116
72
150
160
225
225
150
IUWC1GI15
IUWC1GI30
116
116
116
72
72
72
IUWC2G
IUWC1G2R
IUWC1GGF
IUWC1GGF
IUWC1GIUC
IUWC1GIUC
IUWC1GIUC
Three phase receptacle, straight blade device, Al IUWC1GTSBD
Receptacle/inlet, locking device, 15 A, die cast
IUWC1G30LT
Receptacle/inlet, locking device, 20-30 A, die-cast IUWC1G30LT
75
75
75
225
150
150
Splashproof Cover Plates for Switches sees note 15, 25
Technical Data, Switch
Temperature range
Wire range
Approvals
-20 - +60°C
AWG 14
UL/CSA alt c-UL
Description
Catalogue numbers
Steel
Aluminium
Dimensions, mm
Height Width
Weight
g
Only cover plate, switch ordered separately
Cover plate with single pole switch,125 V, 10 A
Cover plate with double pole switch, 125 V, 10 A
Cover plate with 3-way switch, 125 V 10 A
IUWC1GS
IUWC1G10SP IUWC1G10SPA
IUWC1G10DPA
IUWC1G103W IUWC1G103WA
116
116
116
116
126
130
130
130
72
72
72
72
Enclosed Disconnect Switch with Receptacle, Locking Device see note 26, 27
ON
OFF
Description
Technical Data
Temperature range
Enclosure material
Rated voltage/current, switch
Ingress protection
Approval
Catalogue number
Encl. disconnect switch, receptacle with flange ordered separately IUSE6000
Auxiliary contact, NO-NC
IUAH20AUX
-40 - +70°C
Polycarbonate
600 V/30 A
NEMA3R/12, IP 54
UL, CSA
Dimensions, mm
Height Width Depth
Weight
kg
245
6
160
161
7
Cooper Wiring Devices
Uttag och anslutningsdon enligt NEMA/CSA
Catalogue PM3014E rev 1, September 2002
Device Designations according to ANSI/NEMA - CSA, Receptacle
CHS Controls AB
Florettgatan 33, SE-254 67 Helsingborg, Sweden
Phone +46 42 386100, fax +46 42 386129
chs@chscontrols.se, www.chscontrols.se
Download