Pull-wire Emergency-Stop switches ZQ 900 Technical data Contact variants Standards: 49,5 48 40 71,3 96,4 ¤6,5 133,13 219,7 - 235,7 10 12 ¤16 27 M20x1,5 69,7 98 71,5 • To EN ISO 13850 / IEC 60947-5-5 • Metal enclosure • 4 contacts • Position indicator • Robust design • Large wiring compartment • 3 cable entries M20 • One tension force for wire lengths from 5 to 50 m • Wire up to 50 m long • Reset pushbutton • Twisting of connection ring not possible • Optional signaling lamp • External watertight collar • Wire pull and breakage function • EX version available • AS-Interface Safety at Work available IEC/EN 60947-5-1 IEC/EN 60947-5-5 EN ISO 13850 Enclosure: zinc die-cast, enameled Cover:thermoplastic Protection class: IP65, IP67 suffix N: IP65 to IEC/EN 60529 Contact material:silver Contact type: 1 NC/1 NO or 2 NC/2 NO or 3 NC/1 NO or 2 NC or 4 NC Switching principle: A IEC 60947-5-1 snap action with positive break NC contacts Connection: screw terminals Cable section: max. 2.5 mm² (incl. conductor ferrules) Cable entry: 3 x M20 Uimp: 6 kV Ui: 500 V Ithe: 6A Utilization category: AC-15, DC-13 Ie/Ue: 4 A / 230 VAC 1 A / 24 VDC Max. fuse rating: 6 A gG D-fuse to DIN EN 60269-1 Ambient temperature: −25 °C … +70 ºC Mechanical life: > 1 million operations Indicator lamp:optionally Maximum cable length: 50 m (please observe ambient temperature range and wire supports) Features: wire pull and breakage detection Classification: Standards: EN ISO 13849-1 B10d (NC): 100,000 Mission time: 20 years MTTFd Approvals B10d 0,1 x nop nop 1 NO/1 NC 21 13 22 14 2 NC 21 11 22 12 1 NO/3 NC 21 22 21 22 13 14 11 12 S1 S2 2 NO/2 NC 21 22 21 22 13 14 13 14 S1 S2 4 NC 21 22 21 22 11 12 11 12 S1 S2 d op x h op x 3600 s/h t cycle F Ordering details ZQ 900-➀➁ No. Replace Description ➀ 11 13 22 02 04 ➁ N 2-2 1 NO/1 NC 1 NO/3 NC 2 NO/2 NC 2 NC 4 NC Without emergencystop pushbutton Without emergencystop pushbutton Note Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. At 5 m distance intermediate wire supports are required, see accessories. Note The screwed PL-M20-24V indicator lamp must be ordered separately, see accessories. The protection class for ordering suffix N is IP65 to IEC/EN 60529. -10 0 10 20 30 40 50 60 70 80 T[°C] 10 20 30 40 50 l [m] For more information, see our online product catalog: www.usa.schmersal.net Pull-wire Emergency-Stop switches Mode of operation Wire pull and breakage detection 1 Legend 1 Not actuated 2 Wire pull detection 3 Wire breakage detection 1 2 0 F 3 0 Mounting instructions One-side operation Legend 1 Wire rope (STQ441-SC) 2 Eyebolt (STQ441-EB) 3 Spring (STQ441-SS) 4 Wire clamp (STQ441-CC) 5 Tensioner (STQ441-TB) 6 Wire thimble (STQ441-TH) 7 Shackle (S900-SH) 8 Rope tensioner (S900) A B C max. 50 m B C 3-5 m A 0,1m 64 Position indicator Emergency-stop pushbutton Reset button 2 4 6 B C 5 6 4 max. 50 m 2 1 4 6 3 2 4 6 3 2 3-5 m A 0,1m 8 Mounting instructions 2 1 2 Thimble deformation As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. For more information, see our online product catalog: www.usa.schmersal.net 2-3