CONTINUOUS DUTY 4" BLOWER • 115 VOLT AC, 60 Hz • 220

advertisement
MODELS 36760-0115 FLANGEMOUNT
36760-0220 FLANGEMOUNT
36770-0115 FLEXMOUNT
36770-0220 FLEXMOUNT
FEATURES
• Extended Life Induction Motor
• Tough Reinforced Thermoset Plastic Housing
• Continuous-Duty Motor with
Thermal Overload Protection
• Flangemount Mounts to any Flat Surface
• Flexmount Universal Bracket Permits Outlet to
Face any Direction
• Slip-on Inlet Ducting Connection
• Efficient High Volume Air Flow
• Low Current Draw
!
WARNING
Explosion hazard. Motor can spark. Explosion
& death can occur. Do not use where flammable
vapors are present.
• Corrosion-Resistant Materials Throughout
APPLICATION
The Jabsco AC blowers are ideal for ventilating equipment
areas. They may also be used for engine room ventilation on
vessels with diesel powered engines only. THIS BLOWER IS
NOT IGNITION PROTECTED. DO NOT USE TO EXHAUST
FLAMMABLE VAPORS SUCH AS GASOLINE FUMES OR
MOUNT IN AN AREA WHICH MAY CONTAIN FLAMMABLE
FLEXMOUNT INSTALLATION
Mount blower on flat bulkhead surface in highest part of compartment free from spray or deck wash. Blower may be rotated
in mounting bracket to facilitate the shortest route of ducting.
SPECIFICATIONS - Flexmount
Air
Fuse Weight
Model
Flow
Voltage Amps Size lb (kg)
36770-0115 250 CFM 115 AC
1.5
2A
9 (4.1)
AGC
(7.0 m 3/min) 60Hz
36770-0220 200 CFM 220 AC
.35
.5A
9 (4.1)
DIMENSIONAL DRAWING – Flexmount
4
(102)
9-3/16
(233)
9-1/8
(232)
Flexmount
WIRING
All wiring should be done by a qualified electrician and conform with regulations. A minimum of 16 gauge THW wire
should be used for lengths of up to 50 feet from the power
source. A separate ground wire should be secured to the
grounding wire attached to the motor case and connected to
a common ground. A switch of minimum 2 Amp rating may
also be installed in the hot electrical lead (between breaker
and blower) to control blower operation. The neutral conductor should be connected directly from the neutral buss to the
blower motor.
WIRE COLOR CODE
Models
115 Volt
Ground
(earth)
Green
Common
(neutral)
White
FLANGEMOUNT INSTALLATION
Line
(positive)
Black
The blower housing flange should be mounted on a flat bulkhead surface. Selection of a dry cool location will prolong motor
life. When location is selected, cut a 3-5/8" hole through bulkhead to align with discharge port of blower. Secure discharge
port flange to bulkhead using #10 screws and flat washers.
Tighten screws evenly to avoid flange damage.
SPECIFICATIONS - Flangemount
Air
Fuse Weight
Flow
Voltage Amps Size lb (kg)
250 CFM 115 AC
1.5
2A
8 (3.6)
AGC
(7.0 m 3/min) 60Hz
36760-0220 200 CFM 220 AC
.35
.5A
8 (3.6)
Model
36760-0115
DIMENSIONAL DRAWING – Flangemount
4
(102)
4
(102)
9-7/8
(250)
Flangemount
Models 36760 & 36770
CONTINUOUS DUTY 4" BLOWER
• 115 VOLT AC, 60 Hz
• 220 VOLT AC, 50 Hz
8-3/4
(222)
3-5/8
(92)
9
(229)
9-7/8
(250)
1
1
1
1
1
5
35595-1000
18753-0607
18753-0625
35645-0000
35714-0000
35644-0000
35508-0000
Description
1
Motor Kit 115 VAC
Motor Kit 220 VAC
(includes mounting nuts)
Gasket
Blower Housing
Blower Wheel
Blower Housing
Screw 8 x 5/8 SS Self
Tapping Pan Head
2
3
4
5
6
Tested At 220VAC
1.25
Flexmount
INSTALLATION DRAWING
To Discharge
Vent
Bulkhead
4" Ducting
No. 34959-0200
Key
Part
Number
Qty.
1
18753-0607
18753-0625
1
1
1
1
5
35706-0000
35714-0000
35705-0000
35508-0000
Flexmount 36770-0220
Flangemont 36760-0220
Pressure
..8
1.0
.6
..75
RPM
.4
.5
..25
APMPS
0.0
0
Inlet Ducting
Flangemount
INSTALLATION
Bulkhead
THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO
THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS
AVAILABLE FOR YOUR INSPECTION UPON REQUEST.
www.xylemflowcontrol.com
Jabsco is a trademark of Xylem Inc. or one of its subsidiaries.
© 2012 Xylem, Inc. 43000-0672 Rev B 10/2012
80
120
C F M
Tested At 115VAC
Vent
Cover
Inlet
Ducting
40
3
RPM x 1000
1
PARTS LIST – Flangemount
6
160
200
2
.2
1
0
0
240
Flexmount 36770-0115
Flangemont 36760-0115
2.5
2.0
Pressure
15
1.5
RPM
1.0
10
APMPS
0.5
0.0
0
50
100
150
C F M
200
250
6
RPM x 1000
3
4
5
6
7
Bracket Assembly
(includes screw & nut)
Motor Kit 115 VAC
Motor Kit 220 VAC
(includes mounting nuts)
Gasket
Blower Housing
Blower Wheel
Blower Housing
Screw 8 x 5/8 SS Self
Tapping Pan Head
4
Amps
2
Qty.
5
Amps
1
Description
Part
Number
3
2
1
PARTS LIST – Flexmount
Key
1
Static Pressure - Inches of H2O
2
2
5
Static Pressure - Inches of H2O
1
3
4
7
6
4
5
2
0
0
300
Maximum Static Pressure – 1.7 in. H20 (115 VAC)
1.2 in. H20 (220 VAC)
Jabsco, 100 Cummings Center, Ste. 535-N, Beverly, MA 01915
Tel: +1 978 281 0440 Fax: +1 978 283 2619
USA
Jabsco, Bingley Road, Hoddesdon, Hertfordshire, EN11 0BU
Tel: +44 (0) 1992 450 145 Fax: +44 (0) 1992 467 132
UK
NHK Jabsco Co Ltd, 3-21-10, Shin - Yokohama Kohoku-ku, Yokohama 222
Tel: +81 (0) 45 475 8906
Fax: +81 (0) 45 475 8908
JAPAN
Jabsco GmbH, Oststraße 28, 22844 Norderstedt
Tel: +49 (0) 40 53 53 73 0 Fax: +49 (0) 49 53 53 73 11
GERMANY
Jabsco Italia, s.r.l., Via Tommaseo, 6, 20059 Vimercate, Milano
Tel: +39 039 685 2323 Fax: +39 039 666 307
ITALY
Download