Consumer Units - GE Industrial Solutions

advertisement

for residential applications

Consumer units

Off-the-shelf units ready for installation – just select MCBs!

Consumer unit overview

Main switch consumer units

RCD consumer units

Split load consumer units

Dual tariff, time delay

Modular device enclosures

9

10

4

6

7

8

MCBs, RCBOs and RCDs

High performance circuit protection to suit every requirement.

Mini Trips 11

MCBs, RCBOs and RCDs

Modular control devices

12

13

Accessories

Locks, blanks, shrouds, links and terminal bars

Dimensions

14

15

Contents

The Company’s policy is one of continuous development and improvement of its products and, therefore, the right is reserved to supply products which may differ from those described and illustrated in this publication.

3

Consumer units

Comprehensive cable and mini-trunking entries with clean, resealable knock-out facilities.

Neutral bar shroud moulded in the base is simply knocked out as required.

The pan assembly can be easily removed with a half turn of two screws.

4

Stylish design with safety built in

The attractive two tone contoured unit is manufactured from flame retardant self-extinguishing material which is also impact resistant.

Manufactured in accordance with all

British and European standards BS5486

Pt 12 and 13, BSEN60439.3.

The unit has been designed to enable the installer to easily comply with the requirements of the 16th edition IEE wiring regulations (BS7671).

Every GE Power Controls consumer unit is supplied with a full set of labels, an installer's instruction leaflet and a userfriendly card to be left with the customer.

Consumer units

Pan assembly design ensures fast MCB installation.

Comprehensive range of clean resealable knock-outs for cable and mini-trunking entries.

Full shrouding ensures protection from live and neutral connections with the cover off.

Colour coded labels for easy identification.

Moulded in the base is a snap-off shroud for complete shrouding of the neutral bar.

Fixed earth bar with ample terminations accepting up to

16mm 2 conductors.

Choice of main switch or RCD as incoming device.

Unique entry facilities for

25mm 2 tails and

16mm 2 earthing and bonding conductors.

Low side wall allows easy access.

Easily removed pan assembly.

Busbar design permits simple connection and removal of MCBs.

Clearly numbered neutral bar all ways capable of accepting

16mm 2 conductors.

Moulded one-piece base with option of 3 or 4 point fixing.

All GE Power Controls consumer units are pre-assembled and are ready to accept MCBs.

Full length busbar shroud.

The complete consumer unit range has been designed within four widths and one depth.

5

6

Main switch consumer units

INSULATED CONSUMER UNITS

MCB

WAYS

2

4

6

9

13

MAIN

SWITCH

63A

100A

100A

100A

100A

HxDxW

CODE

A

C

D

B

B

ORDER REF.

SHORT

LONG

VC2 F018701000

VC4

VC6

VC9

VC13

F018702000

F018703000

F018704000

F018705000

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

100A DP main switch controls all circuits (VC2 -63A)

Prewired connections between main switch and neutral bar

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Neutral shroud facility

VC13, covers removed

METAL CONSUMER UNITS

MCB

WAYS

2

4

6

9

13

MAIN

SWITCH

63A

100A

100A

100A

100A

HxDxW

CODE

A

C

D

B

B

ORDER REF.

SHORT

LONG

VCM2 F018401000

VCM4

VCM6

VCM9

VCM13

F018402000

F018403000

F018404000

F018405000

VCM13, covers removed

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

100A DP main switch controls all circuits (VCM2 - 63A)

Prewired connections between main switch and neutral bar

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Can be converted to a flush fitting unit

RCD consumer units

INSULATED RCD CONSUMER UNITS

MCB

WAYS

30mA

MAIN RCD

100mA

2 63A

4

6

9

13

80A

80A

80A

80A

6

9

13

80A

80A

80A

HxDxW

CODE

A

B

C

D

C

D

B

B

ORDER REF.

SHORT

LONG

VCA2 F018711000

VCA4

VCA6

VCA9

VCA13

F018712000

F018713000

F018714000

F018715000

VCB6

VCB9

VCB13

F018723000

F018724000

F018725000

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

80A DP RCD controls all circuits (VCA2 - 63A)

Prewired connections between RCD and neutral bar

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

Minimum IP41

4 way blank shield

Neutral shroud facility

VCA13, covers removed

METAL RCD CONSUMER UNITS

MCB

WAYS

30mA

MAIN RCD

100mA

2 63A

4

6

9

13

6

9

13

80A

80A

80A

80A

80A

80A

80A

HxDxW

CODE

A

C

D

B

B

B

C

D

ORDER REF.

SHORT

LONG

VCMA2 F018406000

VCMA4

VCMA6

VCMA9

VCMA13

VCMB6

VCMB9

VCMB13

F018407000

F018409000

F018411000

F018413000

F018410000

F018412000

F018414000

VCMA13, covers removed

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

80A DP RCD controls all circuits (VCMA2 - 63A)

Prewired connections between RCD and neutral bar

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Can be converted to a flush fitting unit

7

8

Split load consumer units

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

100A DP main switch controls all circuits

80A 30mA DP RCD controls protected circuits

Prewired connections between main switch and RCD

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

Minimum IP41

4 way blank shield

Neutral shroud facility

VC5A5, covers removed

INSULATED SPLIT LOAD CONSUMER UNITS

8

8

9

10

10

10

MCB

WAYS

ISO

SPLIT

RCD

8

8

6

6

3

4

2

3

4

+

+

+

+

+

5

6

4

5

6

+

+

+

+

+

6

5

3

2

4

6

5

3

3

4

10

14

7

7

+

+

3

7

HxDxW

CODE

C

D

D

D

D

D

D

D

D

C

C

D

ORDER REF.

SHORT

LONG

VC3A3

VC4A2

VC2A6

VC3A5

F018732000

F018731000

F018733000

F018734000

VC4A4

VC5A3

VC6A3

VC4A6

VC5A5

VC6A4

VC7A3

VC7A7

F018735000

F018736000

F018737000

F018738000

F018739000

F018740000

F018741000

F018743000

VCM5A5, covers removed

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

100A DP main switch controls all circuits

80A 30mA DP RCD controls protected circuits

Prewired connections between main switch and RCD

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Can be converted to a flush fitting unit

METAL SPLIT LOAD CONSUMER UNITS

9

10

10

10

14

MCB

WAYS

ISO

SPLIT

RCD

8

8

6

6

3

4

4

5

+

+

+

+

4

3

3

2

6 +

4 +

5 +

6 +

7 +

5

4

3

6

7

HxDxW

CODE

D

D

D

D

D

D

D

C

C

ORDER REF.

SHORT

LONG

VCM3A3

VCM4A2

VCM4A4

VCM5A3

F018416000

F018415000

F018419000

F018420000

VCM6A3

VCM4A6

VCM5A5

VCM6A4

VCM7A7

F018421000

F018422000

F018423000

F018424000

F018489000

Dual tariff and time delay consumer units

INSULATED DUAL TARIFF CONSUMER UNITS

MCB

ISOLATORS

WAYS

NO 1 NO 2

6 3 + 3

12 6 + 6

HxDxW

CODE

C

D

ORDER REF.

SHORT

LONG

VC33 F018785000

VC66 F018783000

METAL DUAL TARIFF CONSUMER UNITS

MCB

ISOLATORS

WAYS

NO 1 NO 2

6

12

3

6

+

+

3

6

HxDxW

CODE

C

D

ORDER REF.

SHORT

LONG

VCM33

VCM66

F018430000

F018435000

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

Two x 100A DP main switches control all circuits

Prewired main switches and neutral bars

Labels for circuit identification

Modular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Can be converted to flush mounting (metal only)

VC66, covers removed

INSULATED SPLIT LOAD TIME DELAY RCD

CONSUMER UNITS

MCB

WAYS

TD RCD

SPLIT

RCD2

10

14

5

7

+

+

5

7

HxDxW

CODE

D

D

ORDER REF.

SHORT

LONG

VCBD5A5

VCBD7A7

F018748000

F018796000

METAL SPLIT LOAD TIME DELAY RCD

CONSUMER UNITS

MCB

WAYS

TD RCD

SPLIT

RCD2

10

14

5

7

+

+

5

7

HxDxW

CODE

D

D

ORDER REF.

SHORT

LONG

VCMBD5A5 F018495000

VCMBD7A7 F018496000

VCBD5A5, covers removed

In accordance with BS5486 part 13 and BSEN60439.3

Pre-assembled ready to accept MCBs

100A 100mA DP time delay RCD controls all circuits

80A 30mA DP RCD controls protected circuits

Prewired connections between main switch and RCD

Labels for circuit identification

Mdular devices can also be fitted (use HDIN accessory)

4 way blank shield

Minimum IP41

Can be converted to flush mounting (metal only)

9

10

In accordance with BSEN60439.3

For mounting all DIN rail modular devices

Surface mounting

Colour RAL 7035

FOR4, E4 and E2

Modular device enclosures

IP30 INSULATED

MOD

WAYS

2

4

IP30 METAL

MOD

WAYS

4

SHORT

ORDER REF.

LONG

E2 F018020000

E4 F018040000

SHORT

ORDER REF.

LONG

FOR4 F017841000

IP54 INSULATED (WITH COVER)

MOD

WAYS

4

8

SHORT

ORDER REF.

LONG

EC4E+N

EC8E+N

F029040350

F029080150

In accordance with BSEN60439.3

For mounting all DIN rail modular devices

Surface mounting

Colour RAL 7035

High degree of protection IP54

Fitted with earth & neutral bars

Total insulation

EC8E+N, EC4E+N

Mini Trips

In accordance with BSEN 60898

ASTA certified

Type B tripping characteristic

Max PSC 3kA

Mini Trip and bases available separately

Colour coded according to rating

I n

The Mini Trip is a plug-in MCB which provides a simple, cost-effective method of upgrading existing installations.

Designed as a simple installation retro-fit device, Mini Trip

MCBs fit directly into existing consumer units (of the appropriate type) and replace the old rewireable fuse carriers. This upgrades the installation to modern circuit breaker technology with the following benefits: easily reset (no more fumbling with fusewire in the dark!) improved protection no risk of accidentally replacing fuse wire with the wrong rating (fire hazard)

As an alternative to the time consuming inconvenience and costly replacement of a consumer unit, Mini Trips now give you the choice!

5A

15A

20A

30A

45A

S H O R T

Mini Trip

LONG

SMT5

SMT15

SMT20

SMT30

SMT45

V099095240

V099095242

V099095243

V099095245

V099095246

Mini Trip Base

S H O R T LONG

SMTB5 V099095290

SMTB15 V099095291

SMTB20 V099095292

SMTB30 V099095293

SMTB45 V099095294

11

12

MCBs, RCBOs & RCDs

1P

1 mod.

Series EP60 - 6kA - characteristics B-C MCB’s

B

In (A) Order nr.

Ref. nr.

Order nr.

C

20

25

32

40

50

60

4

6

10

16

0.5

1

2

3

EP61B06

EP61B10

EP61B16

EP61B20

EP61B25

EP61B32

EP61B40

EP61B50

EP61B63

674265

674266

674267

674268

674269

674270

674271

674272

674273

EP61C0.5

EP61C01

EP61C02

EP61C03

EP61C04

EP61C06

EP61C10

EP61C16

EP61C20

EP61C25

EP61C32

EP61C40

EP61C50

EP61C63

Ref. nr.

672036

672037

672038

672039

672040

672041

672043

672045

672046

672047

672048

672049

672050

672051

Pack

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1/12

1P+N

2 mod

Series DP100 - 10kA - characteristics B-C 30mA RCBO’s

B C

In (A) Order nr.

Ref. nr.

Order nr.

Ref. nr.

25

32

40

6

10

16

20

DPT100B06/030

DTP100B10/030

DPT100B16/030

DPT100B20/030

DPT100B25/030

DPT100B32/030

DPT100B40/030

609673

609674

609676

609677

609678

609679

609680

DPT100C06/030

DPT100C10/030

DTP100C16/030

DTP100C20/030

DPT100C25/030

DTP100C32/030

DPT100C40/030

609714

609715

609717

609718

609719

609720

609721

Pack

1

1

1

1

1

1

1

1P+N

1 mod

25

32

40

6

10

16

20

DPE100B06/030

DPE100B10/030

DPE100B16/030

DPE100B20/030

DPE100B25/030

DPE100B32/030

DPE100B40/030

605007

605008

605009

605010

605011

605012

605013

DPE100C06/030

DPE100C10/030

DPE100C16/030

DPE100C20/030

DPE100C25/030

DPE100C32/030

DPE100C40/030

605021

605022

605023

605024

605025

605026

605027

1

1

1

1

1

1

1

1 /2 3 /4

2P

Series FP - Type AC RCD

In (A) Order nr.

10/30mA

Ref. nr.

16

25

40

63

80

100

FP216/010

FP225/030

FP240/030

FP263/030

FP280/030

FP2100/030

604048

604275

604276

604277

604278

604069

Order nr.

100mA

Ref. nr.

FP225/100

FP240/100

FP263/100

FP280/100

FP2100/100

604050

604055

604060

604065

604070

Also available in 300mA, 500mA and 1000mA versions Type A and S (time delayed) 2P & 4P

Pack

1/6

1/6

1/6

1/6

1/6

2 /1 4 /3

Modular control devices

Bell transformers 220..240V

o/p power

5VA

8VA

10VA

15VA

Order nr.

TRB5

TRB8

TRB10

TRB15

Ref nr.

666638

666650

666636

666637

Time switches

Day

Analogue time switch

Channels

1

1

Day/week

Digital time switch

Channels

2

Modules

1

3

Modules

3

Contactors N/O 230/240V

Rating

20A

40A

63A

Poles

2P

2P

2P

Order nr.

CLSQ11D

CLSQ31D

Order nr.

GLXQ22W30

Order nr.

CTX2020230A

CTX4020230U

CTX6320230U

Ref nr.

666105

666104

Ref nr.

666190

Ref nr.

666131

666146

666155

Surge Arresters 230V

Rating

20kA

20kA

45kA

Poles

1

1P+N

1P+N

Order nr.

SGSP2202

SGMM2202

SGMM2452C

Ref nr.

666547

666525

666528

Electromechanical

Pulsar TS - Staircase time switch

Delay Nominal current

Contact Operating voltage

0.5 - 5min 16A/250v INO 230v

Order nr.

PLTSM

Ref nr.

666511

Pack

12

13

HALF DIN RAIL

ORDER REF.

DESCRIPTION

Half DIN rail adapter

Half DIN rail adapter

Half DIN rail adapter

Half DIN rail adapter

MOD

2

3

4

6

SHORT

HDIN2

HDIN3

HDIN4

HDIN6

Fitted to pan assembly backplate in consumer units to provide full DIN rail.

Must be used when modular DIN rail devices are to be fitted in consumer units.

LONG

F018000182

F018000183

F018000184

F018000185

BLANKING PLATE

DESCRIPTION

Blanking plate

MOD

4

SHORT

BLNK4

ORDER REF.

LONG

F029000072

Unused way(s) blanking plate for front cover of CCUs, design units, distribution boards.

4 module blank plate is preformed in 1 /

2

module steps.

All standard consumer units have 4 module blanking plate included.

BUSBAR SHROUD

DESCRIPTION

Busbar shroud

MOD

3

SHORT

SHR3

ORDER REF.

LONG

F021000000

Unused way(s) busbar shroud for CCUs, MCB pan assemblies and distribution boards.

When fitted correctly prevents direct contact with exposed conductive parts.

DIN RAIL NEUTRAL BAR

DESCRIPTION

DIN rail mounted neutral bar

MOD

1

SHORT

DIN/NB

12 numbered plus 2 unnumbered terminals which can accept max 16mm 2 .

For use on full DIN rails only, eg in design units.

ORDER REF.

LONG

F018000121

14

LOCKS

DESCRIPTION

Modular 200 door lock

SHORT

MOD2LCK

MCB lock TLK

Door lock replaces existing catch

MCB lock unique screw fitted metal lock

MCB lock secures MCB handle in ON (I) or OFF (O) position.

MCB lock padlock can be applied for additional security.

Padlock not supplied.

ORDER REF.

LONG

F017104337

V099901029

Accessories

CONSUMER UNIT DIMENSIONS

A

B

C

D

HxDxW

CODE

A

B

C

D

HEIGHT DEPTH WIDTH

(E) (F)

175 90

208 108

112

218

208 108

208 108

292

370

For details on consumer units refer to pages 4 to 9.

Dimensions

E

F

15

in Europe

GE Power Controls is the European arm of GE Industrial Systems, one of the ten core businesses of the General Electric Company (USA), known internationally for its positive approach to its customers, its people and the world we all live in.

GE Power Controls is a top class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, general purpose control products, enclosures and switchboards.

Most of the global demand for the company's products comes from OEMs, wholesalers, installers and panel-board builders worldwide.

So, these are the facts, now the story behind them. GE Power Controls' name is synonymous with technical expertise, quality of products and services, and the broadness of its range. But this is not enough, in a constantly changing and competitive environment we have to offer all this and more. Over the next few years our product range will be dramatically expanded and renewed .

The goal we have set for quality ensures no less than constant progress, as part of GE's company-wide Six Sigma product and service excellence initiative. This applies not only to our products and services but also to our business conduct, where only the highest standards are good enough.

We believe that our most important asset is the trust our customers put in us.

We earn it by our continuing quest for improvement on every front and our strong commitment to integrity and reliability.

the ne t !

Now on

epowe rcontro www.g

ls.com

GE POWER CONTROLS

Hornhouse Lane

Knowsley Business Park

Liverpool L33 7YQ

T 0870 600 4372

F 0151 549 4546

E gepcuk@gepc.ge.com

GE Power Controls

Download