ISO9001/UL/CUL/EU
There are various regulations and ordinances, public authorizations, and
other approvals that need to be cleared when installing automated systems
around the world. Such conditions differ totally according to the location
and conditions of the user. For example, national laws, local ordinances and
European Union (EU) directives cover wide areas. Some laws and regulations
and conditions are introduced below. We will also explain the effects to be
received as PLC users.
■ISO9001
Manufacturers make products in accordance with a series of documented
quality-related procedures and some users limit their suppliers only to
companies that handle such products. Koyo Electronics Industries Co., Ltd.
manufactures most PLC products we currently market, and has acquired
ISO9001 certification like our other alliance companies. A copy of the ISO
certificate appears in this catalog.
■Underwriters Laboratories (UL/CUL)
The Underwriters Laboratories is one of the most authoritative safety test
execution / accreditation organizations in the world. For safety and for
the purpose of proving compliance, UL approval is required in most user
applications. Among various notable standards provided by the UL, the most
applicable ones are UL508 (commercial-use control panel standards) and
UL1604 (hazardous location standards). For details on the UL, visit their
website (www.ul.com). Our products that have obtained UL certification are
listed in each table. (The CUL certification required for user applications
in Canada is also listed.) For the latest information, visit Koyo Electronics'
website.
■European Union (EU) Directives
This authorization is absolutely indispensable when launching business in
Europe. Although it is similar to one of the critical problems that EU member
countries and the European Economic Area (EEA) currently face, the
directives call for establishing common standards for member countries by
unifying different standards into one. The main purpose of this unification
of standards is to facilitate the buying, selling and transport of products
among countries, and maintain safe working and living environments. The
"directives" that are born as a "harmonization" of such standards serve as
legal conditions when conducting business in Europe at present. It is obliged
to affix CE marks to products that meet such directives in order to clarify
compliance. There is one question that is often asked when we discuss the
CE.
Certification
List of Discontinued
Model Nos.
Model Number
Index
Which "directive" is Applied?
There are several "directives" that are applied to Koyo Electronics' products.
The "directives" are revised and added if necessary.
- Electromagnetic Compatibility (EMC) Directive
This directive provides the standards for guaranteeing that products
released onto the market do not cause other devices including radio and
telecommunications equipment to fail because emitted electromagnetic
waves.
- Machinery Safety Directive
This directive provides the standards for device and installation safety. It
includes several fields such as testing standards that cover both measures
against noise and noise generation.
- Undervoltage Directive
This directive provides the safety standards for electrical equipment that
has a voltage range of 50 to 1000 V AC or 75 to 1500 V DC.
- Battery Directive
This directive provides the standards for manufacturing, recycling and
disposal of batteries.
614
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Where does the Warranty Responsibility Lie as to
the Compliance with These Directives?
Ultimately, the manufacturer bears all responsibility to the extent of various
small points. The manufacturer must perform tests on products and
document not only all test results but also installation procedures necessary
to comply with the directives. Companies that install machines are obliged
to install products in ways that guarantee the maintenance of compliance.
Moreover, when combining products, it is necessary to perform tests
as to whether products can or cannot comply with the directives if used
together. End-users of products must comply with directives that cover the
maintenance and disposal of products and various parts. Although Koyo
Electronics Industries is making the utmost effort to provide the best support
to users, it is impossible to perform tests on our products by making as many
arrangements as all individual directives cite. Therefore, ultimately, it is the
customer’s responsibility to make their devices comply with such directives
(as a whole) and continuously respond to various directives and training
required for compliance.
CE Label-affixed Direct Logic Products
The DL05, DL06, DL205, D3, and D4 series and terminator I/O PLC systems,
which are manufactured by Koyo Electronics Industries, were certified under
EU directives in March 2002. If correctly installed and used, products made
by Host Engineering, Inc. or FACTS Engineering meet the standard conditions
set by the Electromagnetic (EMC) Compatibility Directive, Undervoltage
Directive, and the Machinery Safety Directive shown on the next page.
* It is expected to change in July 2014. Each time in the Company, please check for the CE
marking.
IEC61000-3-2 Power Factor Correction
This standard is designed to reduce the amount of disturbance that a
device feeds back to the power source. The CE marks are affixed to all
Koyo Electronics' power sources. Normally, our power source complies
with 61000-3-2, but the standard itself is not applicable. However, only
the PS24-150D and PS24-300D power source may be used in methods
that do not comply with the 61000-3-2 standard.
- EMC directives and standards related to PLCs
EN50081-1: Electromagnetic compatibility. Generic emission standard.
Residential, commercial and light industry
EN50081-2: Electromagnetic compatibility̶Generic emission standard Part 2: Industrial environment
EN50082-1: Electromagnetic compatibility. Generic immunity standard.
Residential, commercial and light industry
EN50082-2: Electromagnetic compatibilit y̶ Generic immunit y
standard̶ Part 2: Industrial environment
- Directives concerning undervoltage related to
PLCs
E N 61010 -1: S afet y requirements for electrical equipment for
measurement, control and laboratory use
- Individual product standards related to PLCs
EN61131-2: Programmable controllers - Part 2: Equipment requirements
and tests
This standard is used in place of general standards concerning exemptions
and safety mentioned above. However, the general radiation standard is
applied to the following standards as they are.
EN61000-3-2: Harmonics
EN61000-3-3: Voltage Fluctuations
We are changing these test procedures from general standards to
individual product standards.
Koyo Electronics separately prepares "compliance reports" that describe
authorized individual products and parts Nos. When this document has
been written, CE marks were not affixed to all products. Therefore, confirm
whether the CE marks are attached by referring to the table on the next page.
Moreover, regarding the latest information concerning CE certification and
how to obtain "compliance reports," consult with our Sales Division.
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Certification
PLC
Individual Conditions Required for the Use of Direct
Logic Devices
To comply with the conditions specified by the Machinery Safety Directive,
Electromagnetic (EMC) Compatibility Directive, and Undervoltage Directive,
direct logic devices need to meet more complicated installation conditions
than general installation conditions in the U.S. First, examine reports
concerning required individual application conditions.
Next, see the following manual (in English).
- DA-EU-M
The EU installation manual explains installation conditions for complying
with EU directive conditions. For the latest information, download it from
Koyo Electronics' website. The manual can be obtained from the following
link.
www.support.automationdirect.com/compliance.html
Finally, see the EU information that is explained in the user's manual.
Other Reference Material
Although the EMC Compatibility Directive has drawn attention the most, basic
directives such as the Machinery Safety Directive and Undervoltage Directive
set forth restrictions on the installation of control panels. Since there are
such accompanying conditions, purchase the books below and use them as
guidelines.
- BSI publication TH42073: February 1996
Explains the regulations concerning safety and electricity as to the
Machinery Safety Directive.
- EN60204-1
Explains general electric conditions for machines including the precautions
concerning undervoltage and EMC.
- IEC61000-5-2
Explains grounding and wiring configuration concerning EMC.
- IEC61000-5-1
Explains general precautions concerning EMC.
The information in this section describes various standards and conditions
based on the views of Koyo Electronics Industries and for the purpose of
guidelines. The actual standards are issued by third parties or governmental
agencies depending on the circumstances. Therefore, the conditions are
subject to change without prior warning or notice. If standards are changed
the added, some of the information explained in this section may become
invalid.
The following books can be also used as reference.
Title of book
EMC For Systems and Installations
Author
Tim Williams and Keith Armstrong
Publisher
Newnes, Woburn, MA
Title of book
CE From A to Z
Author
Mette Winther Pedersen & Gert Bukkjaer
Publisher
Levison & Johnson & Johnson a/s, Denmark
Title of book
EU Directive Handbook: Understanding the European Union
Compliance Process and What it Means to You
Author
Allen R. Bailey & Melinda C. Bailey
Publisher
St. Lucie Press, Boca Raton, FL
Title of book
Practical Guide to the Low Voltage Directive
Author
Gregg Kervill
Publisher
Newnes, Woburn, MA
Title of book
CE Marking Handbook: A Practical Approach to Global
Safety Certification
Author
David Lohbeck
Publisher
Newnes, Woburn, MA
You can obtain the information mentioned above from the publisher. The
official publisher of relevant directives and related standards is as follows.
The Office for Official Publications of the European Communities
L-2985 Luxembourg
To easily obtain the information, see the website below.
www.europa.eu
Other information sources are shown blow.
Global Engineering Documents
15 Inverness Way East
Englewood, Co 80112-5776
1 (800) 854-7179 (USA)
(303) 397-7956 (International telephone)
(303) 397-2740 (Fax)
www.global.ihs.com
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Certification
List of Discontinued
Model Nos.
Model Number
Index
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
615
Certification
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
NEMA
■National Electrical Manufacturers
Association (NEMA)
NEMA issues a variety of documents that discuss various standards
concerning industrial controllers. Note, however, that those standards are
in the process of being "harmonized" with the IEC and European standards
and, therefore, may be changed. The documents concerning NEMA, IEC, and
CE are marketed as Global Engineering Documents. For details, see Global
Information below.
1 (800) 854-7179 (USA)
(303) 397-7956 (International telephone)
(303) 397-2740 (Fax)
15 Inverness Way, East Englewood, CO 80112-5776 USA
www.global.ihs.com
- ICS 1: Industrial Control and Systems: General Requirements
- ICS 2: Controllers, Contactors and Overload Relays Rated 600 V (Not
more than rated 2000 V AC or 750 V DC)
- ICS 3: Factory Built Assemblies
- ICS 6: Enclosures for Industrial Control Systems
■NEMA Electrical Frame Environmental Protection Rating
Type
1
List of Discontinued
Model Nos.
Location
Indoor
Description
Accidental contact
2
Drip-proof
Indoor
Drip of non-corrosive liquid, depositing of waste
3
Dustproof, rainwater-proof
Outdoor
Dust caused by wind, rainwater, sleet, freezing-resistant
3R
Dustproof, rainwater-proof
Outdoor
In addition to the items above, no damage to the external chassis or mechanism if ice or sleet melts.
Waterproof / Dustproof
Indoor /
Outdoor
Splashing water, permeation of outdoor rainwater, falling water or spraying of water from a hose
4
Certification
Protection
General-purpose
4X
Waterproof / Dustproof
Indoor
In addition to the items above, corrosion resistance
5
Dustproof
Indoor
Depositing of soot, dust and waste
6
Waterproof / Dustproof
Indoor /
Outdoor
Temporary water intrusion due to instantaneous immersion in water, freezing on the chassis
6P
Waterproof / Dustproof
Indoor /
Outdoor
In addition to the items above, immersion in water for a short time
7
Explosion-proof /
Class I group D danger zone
Indoor
Hazardous chemical material and gas
9
Explosion-proof / Class II danger zone Indoor
Hazardous soot and dust
11
Drip-proof / Corrosion-proof
Indoor
Oil immersion, corrosion effects of liquid and gas
12
Drip-proof / Dustproof
Indoor
Fiber, cotton dust, waste, scattering and dripping of congealed non-corrosive liquid
13
Oil-proof / Dustproof
Indoor
Waste, water, oil, scattering of non-corrosive coolant
Model Number
Index
616
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Certification
UL/CUL/CSA Certification No.
PLC
■UL/CUL/CSA Certification No.
Name
Koyo Timer
UL/CUL
CSA
ISO-9000
E 186 879
−
○
Koyo Proximity Sensor
E 198 343
−
○
Koyo PLC
E 189 395
−
○
Koyo HMI (EA7 Series)
E 189 395
−
○
Koyo HMI (GC7 Series)
E 189 395
−
○
Koyo Encoder
E 189 395
−
○
Direct Logic PLC
E 157 382
−
○
Direct Logic PLC Class 1 Div Ⅱ
E 200 031
−
○
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
■How to Read the IP Rating
IP 67 (Example of IP rating)
The first number represents the protective level when solid matter enters the
chassis.
First
Number
Protective Level
0
No protective measures against contact or intrusion of solids
1
Protection against unintentional contact with hands. However,
intentional contact is excluded. Protection against large objects.
2
Protection against contact by fingers.
Protection against middle-sized objects.
3
Protection against contact with tools and wire.
Protection against small-sized objects.
4
Protection against contact with miniature tools and wire.
Protection against miniature objects.
5
6
The second number represents the protective level when liquid enters the
chassis.
Second
Number
Protective Level
0
No protective measures.
1
Protection against dripping condensate.
No effects from condensate dripping on the chassis.
2
Protection against dripping liquid. When the chassis is tilted 15˚ off the
horizontal position, there are no effects of liquid dripping on the
chassis.
3
Protection against rain. No effects against rain coming from an angle
between the horizontal position and less than 60˚.
4
Protection against splashing water from any direction.
5
Protection against water injection from any direction.
Full protection against contact with living organisms and moving parts.
Protection against the influential accumulation of dust.
6
Protection against ship or deck circumstances.
No intrusion of seawater in bad weather.
Full protection against living organisms and moving objects.
Protection against intrusion of dust.
7
Protection against immersion in water. No immersion of water under the
specified pressure and time conditions.
8
Protection against immersion in water with no time restriction under the
specified pressure.
For Details on IP Rating,
See 1976 IEC Publication: Degrees of Protection Provided by Enclosures or www.iec.ch.
Example: IP67 means complete protection against living organisms, protection against intrusion of dust, protection against immersion in water, etc.
Certification
List of Discontinued
Model Nos.
Model Number
Index
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
617
Certification
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Accreditation of Organizations
■SJ Series
■DL05/06 Series
UL
CUL
CE
SJ-00DD1-D
○
○
○
SJ-00DD2-D
○
○
SJ-00DR-D
○
SJ-00AR-D
○
SJ-02DD1-D
SJ-02DD2-D
■Terminator I/O
UL
CUL
CE
UL
CUL
CE
D0-05DD
○
○
○
T1K-01AC
○
○
○
○
○
D0-05DD-D
○
○
○
T1K-01DC
○
○
○
○
○
○
D0-05DR
○
○
○
T1K-08B
○
○
○
○
○
○
D0-05DR-D
○
○
○
T1K-16B
○
○
○
○
○
○
○
D0-05DA
○
○
○
T1K-08B-1
○
○
○
○
○
○
○
D0-05AD
○
○
○
T1K-16B-1
○
○
○
○
○
D0-05AR
○
○
○
T1K-08ND3
○
○
○
○
D0-05AA
○
○
○
T1K-16ND3
○
○
○
○
○
○
○
SJ-02DR-D
○
○
SJ-30DD1-D*1
○
○
Class 1 Div 2
J-00AC
○
○
○
D0-01MC
J-01AC
○
○
○
D0-06DD1
Class 1 Div 2
○
Class 1 Div 2
T1K-08NA-1
○
○
○
○
T1K-16NA-1
○
○
○
○
○
○
J-08ND3
○
○
○
D0-06DD1-D
○
○
○
○
T1K-08TD1
J-08ND3-1
○
○
○
D0-06DD2
○
○
○
○
T1K-08TD2-1
J-16ND3
○
○
○
D0-06DD2-D
○
○
○
○
T1K-16TD1
○
○
○
○
J-08NA
○
○
○
D0-06DR
○
○
○
○
T1K-16TD2-1
○
○
○
○
J-08TD1
○
○
○
D0-06DR-D
○
○
○
○
T1K-08TA
○
○
○
○
J-08TD2
○
○
○
D0-06DA
○
○
○
○
T1K-08TAS
○
○
○
○
J-16TD1
○
○
○
D0-06AR
○
○
○
○
T1K-16TA
○
○
○
○
J-16TD2
○
○
○
D0-06AA
○
○
○
○
T1K-08TR
○
○
○
○
J-08TA
○
○
○
D0-06LCD
○
T1K-16TR
○
○
○
○
J-08TR
○
○
○
F0-08NA-1
○
○
○
T1K-08TRS
○
○
○
○
J-04TRS
○
○
○
D0-10ND3
○
○
○
○
D0-10ND3F
*1 ULRecognized
■PLC Associated
Equipment
UL
D4-HPP-1
○
D2-HPP
○
DV-1000
○
CUL
CE
Class 1 Div 2
○
Certification
○
○
○
○
T1F-08AD-1
○
○
○
○
T1F-08AD-2
○
○
○
○
D0-16ND3
○
○
○
○
T1F-08DA-1
○
○
○
○
D0-10TD1
○
○
○
○
T1F-08DA-2
○
○
○
○
D0-10TD2
○
○
○
○
T1F-16AD-1
○
○
○
○
D0-16TD1
○
○
○
○
T1F-16AD-2
○
○
○
○
D0-16TD2
○
○
○
○
T1F-16DA-1
○
○
○
○
D0-08TR
○
○
○
○
T1F-16DA-2
○
○
○
○
T1F-8AD4DA-1
○
○
○
○
○
○
F0-04TRS
D0-08CDD1
○
○
○
○
T1F-8AD4DA-2
○
○
○
D0-07CDR
○
○
○
○
T1F-16RTD
○
○
○
○
F0-04AD-1
○
○
○
T1F-14THM
○
○
○
○
F0-04AD-2
○
○
○
T1H-EBC100
○
○
F0-2AD2DA-2
○
○
○
T1K-HSIO
F0-4AD2DA-1
○
○
○
T1K-DEVNETS
F0-4AD2DA-2
○
○
○
T1K-MODBUS
○
○
○
○
F0-04THM
○
○
○
T1H-CTRIO
○
○
○
○
F0-04RTD
○
○
○
○
○
○
List of Discontinued
Model Nos.
D0-HSIO
Model Number
Index
D0-DCM
H0-ECOM100
○
○
○
○
○
○
○
○
○
○
D0-DEVNETS
D0-MLINK
○
H0-CTRIO
H0-CTRIO2
618
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
○
○
○
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Certification
PLC
■DL205 Series
D2-230
■DL205 Series
UL
CUL
CE
Class 1 Div 2
○
○
○
○
F2-04AD-1
■D4 Series
UL
CUL
CE
Class 1 Div 2
○
○
○
○
CPU
HMI
UL
CUL
D2-240
○
○
○
○
F2-04AD-2
○
○
○
○
D4-430
○
○
D2-250-1
○
○
○
○
F2-08AD-1
○
○
○
○
D4-440
○
○
D2-260
○
○
○
○
F2-08AD-2
○
○
○
○
D4-440DC-1
○
○
D2-265
○
○
○
F2-02DA-1
○
○
○
○
D4-450
○
○
D2-03B-1
○
○
○
○
F2-02DA-2
○
○
○
○
SU-6M
D2-04B-1
○
○
○
○
F2-02DA-1L
○
○
○
○
SU-6M-C
D2-06B-1
○
○
○
○
F2-02DA-2L
○
○
○
○
Expansion Unit and Cable
○
○
○
○
F2-02DAS-1
○
○
○
○
D4-EX
○
○
D2-03BDC1-1
○
○
○
○
F2-02DAS-2
○
○
○
○
D4-EXDC
○
○
D2-04BDC1-1
○
○
○
○
F2-08DA-1
○
○
○
○
D4-EXCBL-1
○
○
○
○
D4-EXCBL-2
D2-06BDC1-1
○
○
○
○
F2-08DA-2
D2-09BDC1-1
○
○
○
○
F2-4AD2DA
○
Base Units
D2-08ND3
○
○
○
○
F2-8AD4DA-1
○
D4-04B-1
○
○
D2-16ND3-1
○
○
F2-8AD4DA-2
○
D4-06B-1
○
○
D2-16ND3-2
○
○
○
○
F2-04RTD
○
○
○
○
D4-08B-1
○
○
D2-32ND3
○
○
○
○
F2-04THM
○
○
○
○
Discrete Input Modules
H2-ERM100
○
○
○
D4-16ND2
○
○
D2-64ND3* 1
○
○
H2-EBC100
○
○
○
D4-16ND2F
○
○
D2-08NA-1
○
○
○
○
D2-HSIO
D4-32ND3-1
○
○
D2-08NA-2
○
○
○
○
D2-DCM
○
○
○
○
D4-64ND2
○
○
D2-16NA
○
○
○
○
F2-DEVNETS-1
○
○
○
○
D4-08ND3S
○
○
D2-04TD1
○
○
○
○
D2-MLINK
○
○
○
D4-08NA
○
○
D2-08TD1
○
○
○
○
D2-02PM
○
○
○
D4-16NA
○
○
D2-08TD2
○
○
○
H2-CTRIO
○
○
○
D4-16NE3
○
○
D2-16TD1-1
○
○
H2-CTRIO2
○
○
○
F4-08NE3S
○
○
○
D2-16TD1-2
○
○
○
○
D2-CTRINT
○
○
○
D2-16TD2-2
○
○
○
○
F2-08SIM
○
○
○
D4-08TD1
○
○
D2-32TD1
○
○
○
○
D2-CM
○
○
○
○
D4-16TD1
○
○
D2-EM
○
○
○
○
D4-32TD1
○
○
D4-64TD1
○
○
○
D2-32TD2
○
Class 1 Div 2
ENCODER
COUNTER
Discrete Output Modules
D2-64TD1* 1
○
○
D2-08TA
○
○
○
○
F4-08TD1S
○
○
F2-08TA
○
○
○
○
D4-16TD2
○
○
D2-12TA
○
○
○
○
D4-32TD2
○
○
D2-04TRS
○
○
○
○
D4-08TA
○
○
D2-08TR
○
○
○
○
D4-16TA
○
○
F2-08TR
○
○
○
D4-08TR
○
○
F2-08TRS
○
○
○
D4-16TR
○
○
D2-12TR
○
○
○
○
F4-08TRS-1
○
○
D2-08CDR
○
○
○
○
F4-08TRS-2
○
○
Certification
List of Discontinued
Model Nos.
Model Number
Index
*1 ULRecognized
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
SENSOR
INFORMATION
D2-09B-1
D2-32ND3-2
CE
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
619
Certification
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
■D4 Series
UL
■PZ Series
CUL
CE
Class 1 Div 2
Analog Modules
■D3 Series
NK
UL
PZ1-8ND1-6TD1
CPU
CUL
CE
F4-04AD
○
○
PZ1-8ND1-6TD1-A
SR-21-EX
○
○
F4-04ADS
○
○
PZ1-8ND1-6TR1
D3-330
○
○
F4-08AD
○
○
PZ1-8ND1-6TR1-A
SA-21-EX
○
○
F4-16AD-1
○
○
PZ1-R
D3-330P
○
○
○
F4-16AD-2
○
○
PZ1-T
Base Units
F4-04DA-1
○
○
PZ2-16ND1-10TD1
D3-05B-1
○
○
○
F4-04DA-2
○
○
PZ2-16ND1-10TD1-A
D3-05BDC
○
○
○
F4-04DAS-1
○
○
PZ2-16ND1-10TR1
E-03B
○
○
F4-04DAS-2
○
○
PZ2-16ND1-10TR1-A
D3-10B-1
○
○
○
F4-08DA-1
○
○
PZ2-R
D3-10BDC
○
○
○
F4-08DA-2
○
○
PZ2-T
D3-08B-1
○
○
○
F4-16DA-1
○
○
PZ3-16ND1-16TD1
Discrete Input Modules
F4-16DA-2
○
○
PZ3M
F4-08RTD
○
○
PZ3-T
F4-08THM
○
○
PZ3E1
Remote I / O
○
○
D3-08ND2
○
○
○
D3-16ND2-1
○
○
○
D3-08NA-1
○
○
○
PZ3E2
D3-08NA-2
○
○
○
PZ3E3
○
D4-RM
○
○
D3-16NA
○
○
○
D4-RS
○
○
D3-08NE3
○
○
○
D4-RSDC
○
○
D3-16NE3
○
○
○
H4-ECOM100
○
○
Discrete Output Modules
H4-EBC100
○
○
D3-08TD1
○
○
○
H4-ERM100
○
○
D3-16TD1-1
○
○
○
D3-16TD2
○
○
○
D3-08TA-2
○
○
○
Communication Modules
Class 1 Div 2
D4-DCM
○
○
F4-16PID
○
○
D3-08TR
○
○
○
F4-4LTC
○
○
D3-16TR
○
○
○
H4-CTRIO
○
○
○
○
○
○
○
Analog Modules
D3-02DA
Communication Modules
D3-232-DCU
○
E-02DM-R1
D3-HSC
○
○
○
D3-08SIM
○
○
○
D3-FILL
○
○
Programmer
D3-HP
Certification
D3-HPP
List of Discontinued
Model Nos.
Model Number
Index
620
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Certification
PLC
■HMI
NX-B20
■Rotary Encoder
UL
CUL
CE
UL
CUL
CE
○
○
○
Class 1 Div 2
TRD-2E□A
○
○
○
NX-B21
○
○
○
TRD-2E□B
○
○
○
NX-B20-B
○
○
○
TRD-2E□V
○
○
○
NX-B21-B
○
○
○
TRD-GK□-R
○
NX-G11
○
○
○
TRD-GK□-RC2
○
GC-A14
○
○
○
TRD-GK□-RZ
○
GC-A14-R
○
○
○
TRD-GK□-RZC2
○
EA7-S6M-RS
○
○
○
TRD-GK□-RZC2L
○
EA7-T6CL-RS
○
○
TRD-GK□-RZL
○
EA7-S6M-S
○
○
TRD-J□-RZ
○
EA7-T6CL-S
○
○
TRD-J□-RZC
○
EA7-T10C-SG
○
○
TRD-J□-RZCL
○
EA7-T12C-S
○
○
TRD-J□-RZCW
○
EA7-T15C-S
○
○
EA7-T8C-S
○
○
○
TRD-J□-RZCWL
○
○
TRD-J□-RZL
○
GC-76LC
○
TRD-J□-RZS
○
GC-73LCL-R
○
TRD-J□-RZSL
○
○
○
TRD-J□-RZV
NS6410TX3S
○
○
○
TRD-J□-RZVC
○
NS6412TX3S
○
○
○
TRD-J□-RZVCW
○
EA-AC*1
○
○
TRD-J□-RZVS
○
TRD-J□-RZVW
○
TRD-J□-RZVWS
○
TRD-J□-RZW
○
TRD-J□-RZWL
○
TRD-J□-RZWS
○
GC-73LM-R
*1 ULRecognized
■Proximity Sensor
UL
CUL
CE
APS30-34CK-Z
○
○
○
TRD-J□-RZWSL
APS4-12M-Z
○
○
○
TRD-MX□A
○
○
○
○
TRD-MX□B
○
○
○
○
TRD-MX□V
○
○
○
○
APS4-12S-Z
○
APS2.5-8M-E
Class 1 Div 2
○
○
APS4-12M-E
○
○
○
TRD-N□-RZL
○
APS4-12M-E1
○
○
○
TRD-N□-RZV
○
APS4-12M-E2
○
○
○
TRD-N□-RZVW
○
APS4-12S-E
○
○
○
TRD-N□-RZW
○
○
TRD-N□-RZWL
○
TRD-NA□□NW*2
APS4-12S-E1
APS4-12S-E2
○
○
○
○
○
○
○
○
○
○
○
○
TRD-NA□RNWE*2
○
○
○
TRD-NA□RPW
○
KCV-□T*1
○
○
TRD-NA□RPWE
○
KCV-□T-C*1
○
○
TRD-NH□-RZ
○
KT-V4S*1
○
○
TRD-NH□-RZL
○
KT-V4S-C*1
○
○
TRD-NH□-RZV
○
TC-V6*1
○
○
TRD-NH□-RZVW
○
TC-V6-C*1
○
○
TRD-NH□-RZW
○
TC-V6S*1
○
○
TRD-NH□-RZWL
○
TC-V6S-C*1
○
○
TRD-S□A
○
TRD-S□B
○
TRD-S□V
○
TRD-SH□A
○
TRD-SH□B
○
TRD-SH□V
○
KCV-□S*1
KCV-□S-C*
1
*1 ULRecognized
○
CE
Class 1 Div 2
COUNTER
1.Proximity sensors
INFORMATION
EMC Compatibility Directive
Compliant standards
EMS/EMI:EN60947-5-2
2.Rotary encoders
EMC Compatibility Directive
Compliant standard
EMS:EN61000-6-2
3.Electronic counters / controllers
Conform to the Low Voltage Directive and the EMC
Compatibility Directive as follows.
(1) Low Voltage Directive
Conformance standard: EN61010-1
If the switching voltage of the contact output
exceeds 150 V, the products conform to the
standard by ensuring basic insulation on the load
side connected to the contact output.
(2) EMC Compatibility Directive
Compliant standards EMI: EN55011
EMS: EN50082-2*
* In the case of the DC power source type, the
products conform to the standards by connecting
an EMI/EMC filter (equivalent to MR-2021 Tokin)
to the power source.
NOTE:
It is expected to change in July 2014. Each
time in the Company, please check for the CE
marking.
Certification
List of Discontinued
Model Nos.
○
TRD-NA□RNW*2
CUL
Our products conform to the EMC directive as
follows.
○
TRD-NA□PWE
UL
ENCODER
○
TRD-NA□□NWF2
■Counter
SENSOR
○
TRD-NA□NWE* 2
TRD-NA□□PW
Class 1 Div 2
○
TRD-N□-RZ
APS2.5-8S-E
HMI
Regarding CE markings, consult with us each time.
Model Number
Index
*2 Except the 2048 resolution
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
621
Download