Auto Power Reclosing Relay S8-300 Auto Power Reclosing Relay S8-300 The S8-300 is an auto reclosing relay that provides automatic reclosing function for protection against the power supply interruptions frequently. This relay will act its protection function to trip automatically when overvoltage or undervoltage is detected. The reclosing function can make the impermanent short circuit status return to the normal condition. The relay can take measurement of each line voltage on three-phase system. utilize an alarm contact connected to a buzzer for signaling to a prompt solution if the fault is still not cleared. The S8-300 also provide with a " Lockout" function in order to inhibit further reclosure attempts following a breaker trip or even to prevent the selective relays for switching to the objects. The relay can in dicate the cause on the front plate as each possible fault occurs, besides it is equipped with RS 485 Modbus for the related information received. FEATURES Breaker open / close indicator. Real - time voltage 4 digits LED display. Programmable adjustment for voltage transfomer ratio. Setting value protected by password. Local display of data recorded at the moment of a fault. Line RMS voltage measurement. ON / OFF / Buzzer relay contact output. With RS 485 output. Immunity test according to IEC 255 standards. Outside dimension compatible for DIN standards (144x144mm) Intemal fault detection. FUNCTIONS 27-Line under voltage relay with definite time delay. 59-Line over voltage relay with definite time. V V 79-Auto reclosing relay with definete time. Reclosing count down time with internal buzzer and contacts output. Disable reclosing external lock. S8-300 Auto Power Reclosing Relay SPECICATION Overvoltage and Undervoltage Rated voltage input General AC 110V, 220V or 380V 30%, 50/60HZ Overload capability Dielectric strength IEC 688, AC 2.3KV/1 minute between terminals AC 3KV/1 minute between all terminals/case 2 x rated 5sec. Overvoltage setting range 100% ~ 130% Overvoltage time delay 0 ~ 99sec. Undervoltage setting range 70% ~ 100% Undervoltage time delay Operating temperature Storage temperature Max.humidity 0 ~ 60 ºC -10 ~ 70 ºC 90% 0 ~ 99sec. Immunity Test Reclosing unit Withstanding impulse voltage Reclose time delay 0 ~ 99sec. The time of reclose 1 ~ 9 times Alarm for reclose internal buzzer Electrical transient in burst Electrostatic discharge Voltage disps and short interuptions and contacts output Disable reclosing external lock or breaker on ORDERING INFORMATION Accuracy < Over/Under voltage setting Time delay =± 0.5% full scale (Whichever is greater) at 0 msec: 50 ms Max. Power supply Nominal voltage AC/DC 85~265 V or DC 20~60 V Burden S8-300 ± 3% of set value or ± 20ms. Model Input voltage 1: AC 110V ( 65V ~ 160V) 2: AC 220V (130V ~ 320V) 3: AC 380V (225V ~ 560V) 0: Option AC < = 7W = 6VA,DC< Power supply Display Type 0.56"H, red LED Digital format 1 row of 4 digits 1: AC/DC 85~265 V 2: DC 20~60 V 0:Option 1 row of 2 digits (reclosing count down time) Detection Input Rated voltage input AC 110V ( 65 ~ 160V) AC 220V (130 ~ 320V) AC 380V (225 ~ 550V) Type External lock & ON verify Output Relay contacts SPST for trip/reclose/buzzer Rated voltage 250V AC/DC Continuous carry 5A Make and carry for 0.5s 30A Make and carry for 3.0s 15A Communication Interface RS485 Protocal MODBUS, RTU framing Baud rate Address range Data format Number of meter 1200 ~ 38400 programmable 1 ~ 255 programmable N.8.1/ N.8.2/ O.8.1/ E.8.1 programmable up to 32 256 (option) Frame Degree IP52 or IP54 RS485 output Y: Yes N: No IEC 61000-4-5 (IEC 255-5) IEC 61000-4-4 (IEC 255-22-4) IEC 61000-4-2 IEC 61000-4-11 S8-300 Auto Power Reclosing Relay CONNECTION DIAGRAM OUTSIDE DIMENSION(Unit:mm) Max. 25 O B- A+ 13 12 11 10 138 Exit Lock ON Verify RS 485 or (RS 232) 144 Trip 8 7 6 Close 5 144 137.4 Voltage L3 L2 L1 3 2 1 Power Supply - 9 +1 -0 Detection Relay Contact Buzzer Panel Cut-Out 4 + P2 P1 138 T1 8 86 144 TAIK ELECTRIC CO., LTD. +1 -0