Safety relay Automatic or manual reset UE 48-2 OS

advertisement

Pgs 160-215 8/10/04 3:49 PM Page 188

UE 48-2 OS

Safety relay

Automatic or manual reset

UE 48-2 OS

188 SAFETY CATALOG 2004

Safety class

Class 4

Supply voltage

24 V DC/AC

Output contacts

Safety

2

Dimensions

87 x 22.5 x 122 mm

Auxiliary

1

Function

Dual-channel wiring with short circuit detection

Supply voltage 24 V AC/DC

Automatic/manual start

External device monitoring (EDM)

Version with connection clamps available

Features

Safety Category 4 approved to

EN 954-1

Stop Category 0 approved to

EN 60 204-1

2 normally open (NO) contacts,

1 normally closed (NC) contact

Automatic/manual reset

External device monitoring (EDM)

3 LED signals

Monitors the integrity of connection of safety circuit and control (ts = 0.5 s)

Suitable for applications with safety optoelectronic barriers with tested static outputs

Applications

Safety optoelectronic barriers (ESPE) with monitored static outputs (OSSD), like FGS, C 4000, MSL, PLS, LSI,

S 3000, C/M 2000, C 4000

Emergency stops according to EN 418

(single and dual channel)

Safety switches for movable guard control (single and dual channel)

Safety mats in compliance with DIN

EN 1760, with 4 wire technology

Pgs 160-215 8/10/04 3:49 PM Page 189

Dimensions

UE 48-2 OS

Functionality

After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain open. If the connected sensor is not activated or the protective field of the connected electrosensitive protective equipment (ESPE) is not broken (i.e. the input circuits are closed), then the normally open contacts close immediately in Automatic

Reset, LED K1 and K2 illuminate. In the case of Manual resetting, this only occurs after pressing and releasing the Reset button.

The activation of the sensor or infringement into the protective field of the non-contact safety device (open state of one of the two input circuits) effects the opening of the normally open contacts (LED K1 and K2 off).

Example of connection of emergency stop button to single channel with manual reset

External device monitoring (EDM)

The unit can take over external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts.

Manual reset

For manual resetting, a pushbutton must be connected to terminals S33 - S34. This

Reset is monitored.

Automatic reset

For ESPE’s: S33 - S35 must be linked for applications with potential free contacts on the input circuit S12 - S35 must be linked.

Cross circuit detection

Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity.

Example of connection between a safety curtain with manual reset and EDM

The UE 48-2 OS 2 unit has screw type terminals.

The UE 48-2 OS 3 unit has removable terminals.

SAFETY CATALOG 2004 189

Pgs 160-215 8/10/04 3:49 PM Page 190

190 SAFETY CATALOG 2004

UE 48-2 OS

General data description

Supply voltage to A1/A2

Electrical output circuit > 25 V AC/60 V DC

Electrical output circuit < 25 V AC/60 V DC

Safety category: EN 954-1

Stop category: EN 60 204

Supply voltage V

S

(A1/A2)

Power consumption

AC mode

DC mode

Residual ripple in DC mode (within the limits of V

S

)

Nominal frequency in AC mode

Control voltage S33/S11 and S21

Control voltage

Control current

Electrical short circuit between S33/S11 and S21 min.

typ.

PELV

PELV or SELV

0

20.4 V AC/DC

50 Hz

17.4 V DC

40 mA

4

24 V AC/DC 26.4 V AC/DC

22 V DC max.

4.6 V A

2.1 W

2.4 V

PP

60 Hz

100 mA

300 mA

Reaction time by cross connection

Switch-on time after cross connection detection

Galvanic separation between A1/A2 and S21, S11, S33

Input circuits (S12, S31, S22, S34, S35)

Input voltage (S12 and S31)

HIGH

LOW

Input current at S12 and S31/S22

Input current at S34/S35

Reset time

Manual (S22/S34)

Automatic (ESPE: S33/S35; potential free: S12/S35)

Activation time for Reset button

Minimum switch-off time/Minimum switch-on time

Permitted test pulse time/Test frequency

Line resistance at the input circuit no

17.4 V DC

-3 V DC

50 ms

7 ms

40 mA

5 mA

50 ms

50 ms

26.4 V DC

+5 V DC

100 mA

50 mA

40 ms

80 ms

1000 µs/10 s

-1

35 Ohm

Synchronization time70 ms

Output circuits (13 - 14, 23 - 24, 31 - 32/33 - 34)

Response time (K1/K2)

Minimum switch-off time70 ms

Relay contacts

Contact type

Contact material

Load capacity of contacts

Switching voltage

Switching current

Total current across all contacts

Application category to EN 60 947-5-1

2 normally open contacts (NO), safety relevant

1 normally open contact (NO), not safety relevant positively guided

Silver alloy; gold-plated

10 V AC/DC

10mA

25 ms

130 ms

230 V AC/30 V DC

6 A

12A

AC-15 Ue 230 V AC, I e

4 A (360 c/h)

AC-15 Ue 230 V AC, I e

3 A (3600 c/h)

DC-13 Ue 24 V DC, I e

4 A (360 c/h)

DC-13 Ue 24 V DC, I e

2.5 A (3600c/h)

Permitted switching frequency

Mechanical service life (switching cycles)

Electrical service life (dependent upon loading)

Operating data

Surge voltage rating (V imp

)

Excess voltage category

1 x 10

2 x 10

7

6

3600 c/h

4 kV

III

Contamination rating of the unit (EN 50 178)

External

Internal

Voltage rating

Test voltage V eff (

50 Hz) EN 60 439-1

Protection type

Housing

Terminals

Radio interference

Screening against interference

Ambient operating temperature

Storage temperature

Cross sections of electrical conductors single strand wire (2x, identical cross section) single strand wire (1x) fine stranded wire with terminal crimps

(2x, identical cross section fine stranded wire with terminal crimps (1x)

Weight

IP 40

IP 20

DIN EN 61 000-6-4

DIN EN 61 000-6-2

-25°C

-25°C

0.14 mm

0.14 mm

0.25 mm

0.25 mm

0.2 Kg

2

2

2

2

3

2

300 V AC

2 kV

+55°C

+75°C

0.75 mm

2.5 mm

0.5 mm

2.5 mm

2

2

2

2

Pgs 160-215 8/10/04 3:57 PM Page 191

Internal circuitry

A1 A2 S34 S35 13 23 31

RESET

SUPPLY

CONTROL-LOGIC

Channel 1 Channel 2

(+) (+) (-)

-

S21

+ +

S11 S33 S12 S31 S22

K1

K2

14 24 32

Connection drawing

Ue 48-2 OS

Selection table

Model

UE 48-

UE 48-

2

2

Output

OS

OS

Connection (terminal type)

Screw Removable

2

3

Supply voltage

24 V DC

D2

D2

We recommend contacting Customer Service for product selection

Part number

6 024 915

6 024 916

SAFETY CATALOG 2004 191

Download