2013 PRODUCT GUIDE 200CLD2000XBXX - 06/2013 - 1000 2013 PRODUCT GUIDE G.I. INDUSTRIAL HOLDING S.p.A. participates in the ECC programme for LCP-HP and FCU. Check on-going validity of certificate: www.eurovent-certification.com or www.certiflash.com COMPANY PROFILE About us Total Flexibility, and the Ability to Deliver Highly Specific Answers. Twenty-five years of experience and a strong entrepreneurial spirit are CLINT’s distinctive features. A winning combination, that offers highly technological and completely flexible solutions to the market. CLINT’s strong point is a capability to provide targeted, customized answers to very specific needs, especially for large installations. By combining its experience in centralized, hydronic air-conditioning systems with advanced plant technology and a number of innovative R&D solutions, CLINT designs, builds and customizes an integrated, comprehensive range of machines for centralized air-conditioning of residential, commercial and industrial buildings, complemented by a widespread pre- and post- sales assistance network with a strong international presence. air experience 1 Company organization Production Cycle Control is at the Heart of Our Philosophy. The company’s production, spreading over 2 production plants, is divided between modern assembly lines and work islands, medium/small cooling units and fan coil units are mostly produced on assembly lines, large refrigerating units and rooftop systems in specially equipped areas. In both cases, the whole production process is subject to thorough checks and controls, both at the end and at intermediate steps. Each unit must go through strict testing, simulating operational conditions on the customer’s site even in the most demanding situations. Pressure, temperature, sound level, vibrations: everything is checked to make sure it complies with set parameters. The company is also strongly geared for maximum customer satisfaction and offers a vast service network relying on very skilled professionals who can carry out unit start-up on customer’s premises, if required, to adjust the machines to the requirements of any system they are connected to. our values All cooling fluids used by CLINT comply with the directives of the Kyoto and Montreal Protocols, they offer DPO=0 (Ozone Destruction Potential=0) and are used in cooling circuits designed to cut down energy dissipation and space usage, and eliminate potential gas leaks in the environment. R407C, R134a and R410A are the refrigerants used by CLINT in its cooling units for residential, commercial and industrial air conditioning systems. On top of that, CLINT post-sales service staff is trained and ready to carry out maintenance operations on machines or dismantle them at the end of their useful life without leaking any gas in the environment. Attention to the environment Being a Modern Firm also Means Operating in Respect for the Environment. CLINT believes in searching for innovative solutions and developing both materials and cooling fluids that comply with the strictest directives on environmental matters; but also achieving high ESEER, and as a result low energy consumption machines. environment 2 Technological progress We Believe in Innovation that Produces Real Benefit. Quality of life achieved through research and development of advanced technologies. The commercial and technological challenges met by CLINT in over twenty-five years of activity have developed, thanks to its customer satisfaction policy, a great attention to individual customers needs and special care in planning and manufacturing details, and state of the art solutions. Furthermore, it also made the company aware that, in order to provide a real benefit for the final user, it had to adopt a working philosophy of production without pollution, and manufacture machines with a very low environmental impact, both on the materials and on the operational consumption front. This enabled CLINT to produce units that are quite simply unique in their class. From the ENERGYPOWER line, producing hot water for sanitary use even when environment conditioning requirements have already been satisfied, to the range in “A CLASS” which allow substantial energy savings, with EER values above 3.1; to the line of MULTIPOWER products, capable of reducing cooling power to perfectly adapt to any air conditioning need, resulting in considerable energy savings compared to traditional systems, to the TURBOLINE product line equipped with revolutionary Turbocor magnetic levitation compressors, flooded evaporators and traditional, Microchannel or evaporating condensers, units that have been designed for exceptional performance. Our products range We Provide Effective Solutions for All Air-conditioning Needs. CLINT offers a complete and integrated range of machines for centralized air conditioning of residential, commercial and industrial building. The rich production line combines a wide range of value added solutions for market and individual customers needs. From fan coil units to chillers and roof-tops, CLINT’s skill and professionalism can grant customers top production standards, attention to details, best ESEER. levels, and noiselessness: CLINT’s a guarantee of ideal comfort. The vast selection of water chillers and heat pumps from 5 to 9000 kW makes up an essential part of CLINT’s production. Roof-top systems are also included in the Company’s « core business », independent conditioning units for commercial and industrial buildings and fan coil units, available in 3 different designs to best satisfy the architectural requirements of any single environment. Completing the vast line of CLINT air-conditioning products, there are also refrigerating machines specifically dedicated to systems with radiating panels and cold beams, systems with an ever increasing presence in the world of thermal comfort, and heat pump units , an alternative to the traditional furnace, dedicated to heating environments in particularly rigid climates. Projected into the future An Increasingly Competitive and High Specific Market Finds Us Ready for New Challenges. COMPANY PROFILE innovation CLINT and its highly entrepreneurial management embody a dynamic and integrated organization, ready to play a lead role in the most demanding markets, anticipating needs and trends while ensuring maximum customer satisfaction, offering not only a product, but the best solution available over time based on customer needs. CLINT meets the challenges of an ever changing market with maximum dedication and determination, planning product strategies that are aimed at designing innovative and technologically advanced units and the research for latest generation components capable of having a decisive role in building machines that have been optimized for every single system requirement. Cutting edge solutions that are able to enter the market and play a leading role, even in specific markets such as the middleeastern one, with tropicalised units with functioning limits of up to 52 °C for external air temperature and the North American one, with units that must comply UL certification. future 3 A fully certified system We Are Strongly Committed to Quality. The company believes in customer satisfaction as an added value for its products. CLINT pursues this objective through research and development of special solutions to grant customers the best results over time, improved performance and higher COP, accompanied by high quality training of its post-sales service professionals and great attention to the increasingly demanding requirements of an ever evolving market. CE: Proving that all products coming from CLINT’s manufacturing plants are made according to European Community directives and regulations. BV: A certification for pressurized fluids, attesting the correct production of refrigeration circuits, in combination with hydraulic ones, of compressor equipped units. UNI EN ISO 9001:2008: Way back in 1999, CLINT was the first Italian Company in the sector to obtain it, confirming its attention to correctly managing industrial processes. This was also perhaps due to an inborn vocation for international markets, very sensitive to quality issues. EUROVENT: Attesting the reliability of Company data on product performance, a guarantee of the actual quality of CLINT’s products and their specific characteristics. Check on-going validity of certificate: www.eurovent-certification.com or www.certiflash.com 4 quality COMPANY PROFILE The force of a group We Made a Name for Ourselves in the Air-conditioning Sector, Actually More than One. Created from the integration of single-product Companies operating in the air conditioning field, process cooling, close control and air treatment, G.I. INDUSTRIAL HOLDING unites a series of industry leading Companies in the international thermo-technical industry. The particularity of G.I. INDUSTRIAL HOLDING is in fact the amount specialization in this field and it is characterized by the synergy of the experience and advanced technological content of each Company. Every structure has its own know-how and its own specializations; within the group, CLINT represents the segment of water coolers, roof-tops, ventconvectors and terminal units, intended for those markets where the demand for air conditioning systems is continuously increasing, but above all where the use of centralized hydronic systems manages to generate the true added value that traditional direct expansion appliances are not able to supply. 5 Our references We Managed to Win the Trust of Many Important Establishments Having been ready to catch some prestigious opportunities for comfort products applications, CLINT can now claim a series of important achievements at international level, showing the quality and efficacy of its engineering solutions. • Hospital of MONDOVÌ, Cuneo, Italy • BRITVIC SOFT DRINKS, Glebe Farm Industries Estate, Rugby, United Kingdom • LANGSTONE PLASTIC, Burmuda Park, Nuneaton, United Kingdom ZALLAQ RESORT, Zallaq, Kingdom of Bahrain • MARCEGAGLIA S.P.A., Gazoldo degli Ippoliti, Mantova, Italy • University of MODENA E REGGIO EMILIA, Modena, Italy • ENEA, Casaccia Researches Centre, Roma, Italy • RAI Experimental Centre, Aosta, Italy • ALEXFERT FERTILIZERS CO., Alexandria, Egypt • Thermal Centre of BORMIO, Sondrio, Italy • AUDI ZENTRUM, Asti, Catanzaro, Italy • PORSCHE FACTORY, Zuffenhausen-Stuttgart, Germany • JSC VYKSA STEEL WORKS, Nizhgerodsky Region, Vyksia, Russian Federation • University in KÖLN, Germany • FIAT-MIRAFIORI Plant, Torino, Italy • Université Paris X NANTERRE, Paris, France • NUOVO PIGNONE Plant, Porto Salvo, Vibo Valentia, Italy • Hospital LUIGI SACCO, Milano, Italy • University of BARI, Italy • I.N.P.S. Offices, Cosenza, Italy • ARCIMBOLDI’S Theatre, Milano, Italy • Atelier GUCCI, Paris, France • ROLEX Headquarters, Genève • IPERAL Shopping Mall, Morbegno, Sondrio, Italy • IPERAL Shopping Mall FUENTES, Piantedo, Sondrio, Italy • DANIELI S.P.A. Headquarters, Buttrio, Udine, Italy • ARBEITKAMMER, Villach, Austria • GENERAL SERVICES OFFICER, New Dehli, India • MAGNA SPECIALIST CONFECIONERS, Telford, Shropsire, United Kingdom • A.D.R. LEONARDO DA VINCI Airport, Fiumicino, Roma, Italy • MEDIA BIT Village, Torino, Italy • RETAL CZECH, Melnik, Czech Republic • TILAB, Researches Centre TELECOM ITALIA S.p.A., Torino, Italy • HOTEL YAVOR, Sunny Beach Black Sea, Bulgary • Gallerie LAFAYETTE, Paris, France • CHALVIGNAC PRUHLO Distillation, Jarnac Champagne, France • C.N.R. Monterotondo Scalo, Roma, Italy 6 TECHNOPLANTS Aerospace Application Caselle, Torino - Nola, Napoli - Italy COMPANY PROFILE Polo Fieristico FIERA MILANO Rho-Pero, Milano. • MINISTRY OF FINANCE, Sofia, Bulgary • Istituto SUPERIORE di SANITÀ, Roma, Italy • SWISS EMBASSY, Washington DC, U.S.A. • Ministry of theTREASURY, Roma, Italy • MOPCO UREA PLANT, Damietta, Egypt • SWISS RE Italia, Roma, Italy • INTERGREEN UK LTD, Salding, Linolnshire, United Kingdom • SCHOKOLADENWERK BERGGOLD GMBH, Poessnek, Germany • SAGEM COMMUNICATION, France • SINALCO INTERNATIONAL GMBH, Germany • TECHNOPLANTS • TONSTUDIO SUNSHINE-MUSIC, Wien, Austria • Aerospace Application • VERPAKKINGS INDUSTRIES, Netherlands • Caselle, Torino - Nola, Napoli - Italy • CP KELCO OY, Äänekoski, Finland • STADE DE FRANCE, Paris • SAVANNAH MALL, Polokwane, South Africa • FERRARI Car showroom, Prato, Italy • BC-TECHNOLOGY GMBH, Frankfurt/Main, Germany • FELTRINELLI bookstore, Roma, Italy • BOEHLER SCHWEISSTECHNIK, Kapfenberg, Austria • THERMO LOGISTIK-MUELSEN, St. Jacob, Germany • ABN AMBRO BANK, Hoorn, Nedtherlands • ENEL S.p.A., Pisa, Italy • CANTINA DEI COLLI ROMAGNOLI, Imola, Italy • FA. HAASE ENERGIETECHNIK AG, Neumuenster, Germany • LE COCCINELLE Shopping Mall, Osimo, Ancona, Italy • MONTE DEI PASCHI DI SIENA Bank, Bari, Italy • WITS SCIENCE CENTRE, Polokwane, South Africa • JACKSON, MS Federal Courthouse, USA • NATIONAL BANK OF GREECE, Athens, Greece • AMPERE, AQUA, ART, Wien, Austria • EUROPEAN BATTERIES, Espoo, Finland • ALSTOM POWER LTD, Derbyshire, United Kingdom • RESA SYSTEMS GMBH, Saarwellingen, Germany • MALL OF MAURITIUS, Bagatelle, Mauritius • HERMES SHOPPING MALL, Skazysko-Kamienna, Poland our solution 7 CHAPTER 1 Cooling mode Aircooled liquid chillers and heat pumps with axial fans. Heating Power (kW) Page CHA/IK/WP 15÷61 4-11 5-14 20 - 21 CHA/CLK 15÷81 4-20 5-24 22 - 23 CHA/K 91÷151 24-42 30-55 24 - 25 CHA/K/ST 91÷151 24-42 30-55 20 60 100 140 180 26 - 27 kW CHA/ML/ST 41÷71 7-21 11-22 28 - 29 CHA/ML/ST 91÷151 20-47 29-52 30 - 31 CHA/ML/ST 182-P ÷ 302-P 44-129 57-114 20 60 100 140 180 32 - 33 kW MR 50-80 - 20 60 100 140 180 34 - 35 kW CHA/K 182-P÷604-P 47-177 54-187 36 - 37 CHA/K/ST 182-P÷604-P 47-177 54-187 60 100 140 180 220 38 - 39 kW CHA/K 726-P÷36012-P 199-1051 228-1210 320 8 570 820 1070 1320 kW 40 - 41 Cooling mode Heating Page CHA 802÷3204 200-720 218-738 INDEX Power (kW) 42 - 43 CHA 702-V÷5602-V 170-1500 190-1342 340 690 1040 1390 1740 44 - 45 kW CHA/K/FC 91÷151 27-42 - 46 - 47 CHA/K/FC 182-P÷604-P 52-174 - 10 50 90 130 170 48 - 49 kW G.I. INDUSTRIAL HOLDING S.p.A. is not responsible for possible mistakes of this catalogue and can change, without previous notice, the present data. Legenda Versions: Compressor: Fans: Exchanger: Axial Only heating Scroll Centrifugal Shell and tube Free-Cooling R134a Heating/Cooling Semi-hermetic Plug-Fan Flooded shell and tube DHW R407C Microchannel Web Monitoring management H2O Screw Inverter Refrigerant: Rotary High ESP fans Plate Solutions: Only cooling Turbocor A Class Centrifugal 4 pipes Multi use R410A 9 Cooling mode Heating Power (kW) Page CHA/K/FC 726-P÷36012-P 208-1102 - 120 380 640 900 1160 50 - 51 kW CHA/FC 642÷2204 165-600 - 52 - 53 CHA/FC 702-V÷4602-V 177-1163 - 130 410 690 970 1250 54 - 55 kW CHA/Y 1202-A÷4202-A 220-924 - 56 - 57 CHA/Y 1202-B÷6802-B 221-1597 225-1438 58 - 59 CHA/IY/WP 1352÷4402 278-1133 282-1148 60 - 61 CHA/IY/EP 1352÷4402 278-1133 283-1156 62 - 63 CHA/TTY 1301-1÷5004-2 248-1456 - 400 10 770 1140 1510 1880 kW 64 - 65 Cooling mode Heating Page CHA/Y/FC 1202-B÷6002-B 217-1460 - INDEX Power (kW) 66 - 67 CHA/TTY/FC 1301-1÷5004-2 246-1443 - 160 500 840 1180 1520 68 - 69 kW G.I. INDUSTRIAL HOLDING S.p.A. is not responsible for possible mistakes of this catalogue and can change, without previous notice, the present data. Legenda Versions: Compressor: Fans: Exchanger: Axial Only heating Scroll Centrifugal Shell and tube Free-Cooling R134a Heating/Cooling Semi-hermetic Plug-Fan Flooded shell and tube DHW R407C Microchannel Web Monitoring management H2O Screw Inverter Refrigerant: Rotary High ESP fans Plate Solutions: Only cooling Turbocor A Class Centrifugal 4 pipes Multi use R410A 11 CHAPTER 2 Cooling mode Aircooled liquid chillers and heat pumps with radial fans. Heating Power (kW) Page CRA/K 15÷131 4-33 5-41 72 - 73 CRA/K 182-P÷604-P 47-178 54-187 74 - 75 CRA/K/ST 182-P÷604-P 47-178 54-187 20 12 60 100 140 180 kW 76 - 77 CHAPTER 3 Cooling mode Water cooled liquid chillers and heat pumps for remote condensing. Heating Page CWW/K 15÷151 4-49 5-59 20 60 100 140 180 INDEX Power (kW) 80 - 81 kW CWW/GEO 21÷131 8-44 6-30 20 60 100 140 180 82 - 83 kW CWW/K 182-P÷604-P 55-195 72-237 80 140 200 260 320 84 - 85 kW CWW/K 726-P÷36012-P 224-1242 290-1531 360 660 960 1260 1560 86 - 87 kW G.I. INDUSTRIAL HOLDING S.p.A. is not responsible for possible mistakes of this catalogue and can change, without previous notice, the present data. Legenda Versions: Compressor: Fans: Exchanger: Axial Only heating Scroll Centrifugal Shell and tube Free-Cooling R134a Heating/Cooling Semi-hermetic Plug-Fan Flooded shell and tube DHW R407C Microchannel Web Monitoring management H2O Screw Inverter Refrigerant: Rotary High ESP fans Plate Solutions: Only cooling Turbocor A Class Centrifugal 4 pipes Multi use R410A 13 Cooling mode Heating Power (kW) Page CWW 802÷3204 218-782 247-840 88 - 89 CWW 702-V÷5602-V 185-1630 212-1500 370 750 1130 1510 1890 90 - 91 kW CWW/Y 1302-B÷9003-B 267-2473 293-2589 92 - 93 CWW/IY/WP 1352÷4402 319-1171 386-1439 540 1110 1680 2250 2820 94 - 95 kW CWW/TTY 1801-1÷12806-1 333-3696 - 96 - 97 CWW/TTY/DR 1401-1÷6104-1 280-1546 - 410 1250 2090 2930 3770 98 - 99 kW CWW/CCY 4031÷11682 - 1000 3000 5000 7000 9000 100 - 101 kW RCW 6121÷9282 - 102 - 103 RCW/SL 6122÷9281 - 104 - 105 RCW/SSL 6132÷9282 - 20 14 60 100 140 180 kW 106 - 107 Cooling mode Heating Page MEA/K 15÷151 4-41 5-53 INDEX Power (kW) 108 - 109 MEA/K 182-P÷604-P 50-176 59-193 20 60 100 140 180 110 - 111 kW MEA/Y 1302-B÷9003-B 235-2168 - 240 740 1240 1740 2240 112 - 113 kW RCA/K 4111÷8222 - 114 - 115 RCA/K/SL 4111÷8222 - 116 - 117 RCA/K/SSL 5111÷8222 - 118 - 119 RCA/Y 8141÷9282 - 120 - 121 RCA/Y/SL 8231÷9252 - 122 - 123 RCA/Y/SSL 8151÷8272 - 20 60 100 140 180 124 - 125 kW MR 1500-2500 - 20 60 100 140 180 126 - 127 kW G.I. INDUSTRIAL HOLDING S.p.A. is not responsible for possible mistakes of this catalogue and can change, without previous notice, the present data. Legenda Versions: Compressor: Fans: Exchanger: Axial Only heating Scroll Centrifugal Shell and tube Free-Cooling R134a Heating/Cooling Semi-hermetic Plug-Fan Flooded shell and tube DHW R407C Microchannel Web Monitoring management H2O Screw Inverter Refrigerant: Rotary High ESP fans Plate Solutions: Only cooling Turbocor A Class Centrifugal 4 pipes Multi use R410A 15 CHAPTER 4 Cooling mode Roof Top and condensing units. Heating Power (kW) Page RTA/K/WP 182-R÷453-R 64-171 62-162 130 - 131 RTA/K 182÷804 57-251 60-261 132 - 133 RTA/K/MS 182÷804 57-251 60-261 134 - 135 RTA/K/ECO 182÷804 57-251 60-261 136 - 137 RTA/K/ECO/REC-FX 182÷804 57-251 60-261 90 170 250 330 410 138 - 139 kW MHA/K 15÷151 4-45 4-51 140 - 141 MHA/K 182÷604 50-188 55-193 142 - 143 MRA/K 15÷131 4-36 4-40 144 - 145 MRA/K 182÷604 50-188 55-193 20 16 80 140 200 260 kW 146 - 147 CHAPTER 5 Cooling mode Hydronic air-handled units and supervision systems. Heating Page FVW 12÷74 marvin 0.9-7.3 2.6-16.2 INDEX Power (kW) 150 - 151 FVW 12÷74 floyd 0.9-7.3 2.6-16.2 152 - 153 FVW 12÷74 elmer 0.9-7.3 2.6-16.2 154 - 155 FVW 12÷74 0.9-7.3 2.6-16.2 156 - 157 FIW 12÷74 0.9-7.3 2.6-16.2 158 - 159 HWW/V 22÷83 eurìce 2.1-8.5 2.3-18.8 160 - 161 TCW 42÷104 2.2-10.2 5.8-19.6 162 - 163 UTW 63÷544 4.6-43 9.8-97 20 60 100 140 180 164 - 165 kW DBM-DBA / DRM-DRA - 166 CLIMAFRIEND - 20 60 100 140 180 167 kW G.I. INDUSTRIAL HOLDING S.p.A. is not responsible for possible mistakes of this catalogue and can change, without previous notice, the present data. Legenda Versions: Compressor: Fans: Exchanger: Axial Only heating Scroll Centrifugal Shell and tube Free-Cooling R134a Heating/Cooling Semi-hermetic Plug-Fan Flooded shell and tube DHW R407C Microchannel Web Monitoring management H2O Screw Inverter Refrigerant: Rotary High ESP fans Plate Solutions: Only cooling Turbocor A Class Centrifugal 4 pipes Multi use R410A 17 1 INDEX Aircooled liquid chillers and heat pumps with axial fans. INDEX Page CHA/IK/WP 15÷61 CHA/CLK 15÷81 CHA/K 91÷151 CHA/K/ST 91÷151 CHA/ML/ST 41÷71 CHA/ML/ST 91÷151 CHA/ML/ST 182-P ÷ 302-P MR 50-80 CHA/K 182-P÷604-P CHA/K/ST 182-P÷604-P CHA/K 726-P÷36012-P CHA 802÷3204 CHA 702-V÷5602-V CHA/K/FC 91÷151 CHA/K/FC 182-P÷604-P CHA/K/FC 726-P÷36012-P CHA/FC 642÷2204 CHA/FC 702-V÷4602-V CHA/Y 1202-A÷4202-A CHA/Y 1202-B÷6802-B CHA/IY/WP 1352÷4402 CHA/IY/EP 1352÷4402 CHA/TTY 1301-1÷5004-2 CHA/Y/FC 1202-B÷6002-B CHA/TTY/FC 1301-1÷5004-2 20 - 21 22 - 23 24 - 25 26 - 27 28 - 29 30 - 31 32 - 33 34 - 35 36 - 37 38 - 39 40 - 41 42 - 43 44 - 45 46 - 47 48 - 49 50 - 51 52 - 53 54 - 55 56 - 57 58 - 59 60 - 61 62 - 63 64 - 65 66 - 67 68 - 69 1 19 1 CHA/IK/WP 15÷61 HEAT PUMPS WITH AXIAL FANS, INVERTER ROTARY/SCROLL COMPRESSORS PLATE EXCHANGERS AND PUMP KIT. FROM 6 kW TO 16 kW. UNIT DESCRIPTION CHA/IK/WP 15÷61 IDROINVERTER heat pumps and water chillers are designed to meet the needs of small domestic or service sector environments. Equipped with R410A refrigerant gas and INVERTER Rotary/Scroll compressors they are extremely functional and reliable units. In fact, the inverter device controls and continuously modulates the compressor speed, keeping the temperature of the water delivered to the system stable and constant and adapting it perfectly to the thermal load of the places where terminal units it feeds are installed. This obtains high energy efficiencies and ESEER values higher than conventional units, and a reduction of compressor starting peak currents, thus considerably reducing the risk of malfunctioning or breakages. Moreover, IDROINVERTER does not require inertial storage tanks, since the refrigerating capacity delivered is constantly equal to that required while guaranteeing very quiet operation because the fans adjust their speed to the real load of the system, with benefits above all during the night. It also prevents shutdown due to unexpected overloads, by means of an innovative control system which, on being activated, reduces the refrigerating capacity delivered while keeping the unit running. VERSIONS CHA/IK/WP Standard unit 20 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyurethane powder painting. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch and an antifreeze heater. • Electronic thermostatic valve. • R410A refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • Water circuit includes circulator, safety valve, gauge and expansion vessel. Loose accessories: CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A 15 25 41 61 Cooling capacity (1) kW Absorbed power (1) kW EER (1) Cooling Cooling capacity (2) kW Absorbed power (2) kW EER (2) Cooling capacity (1) kW Cooling Absorbed power (1) kW (EN14511 value) EER (1) Heating capacity (3) kW Absorbed power (3) kW COP (3) Heating Heating capacity (4) kW Absorbed power (4) kW COP (4) Heating capacity (3) kW Heating Absorbed power (3) kW (EN14511 value) COP (3) Quantity n° Compressors Type Fans n° Condenser Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Water flow l/s Pump nominal power kW Pump available static press. kPa Water circuit Expansion vessel l Water connections ”G Sound power STD (5) dB(A) Sound pressure STD (6) dB(A) Transport weight Kg Weights Operating weight Kg 4.7 1.5 3.13 6.1 1.6 3.81 4.6 1.6 2.88 5.5 1.7 3.24 5.9 1.4 4.21 5.6 1.7 3.29 1 6.2 2.0 3.10 8.1 2.1 3.86 6.1 2.1 2.90 7.4 2.3 3.22 8.2 2.0 4.10 7.5 2.3 3.26 1 9.0 2.9 3.10 11.9 3.1 3.84 8.9 3.0 2.97 12.0 3.7 3.24 12.8 3.1 4.13 12.1 3.7 3.27 1 Twin Rotary 2 1.65 10.9 3.5 3.11 14.1 3.7 3.81 10.7 3.7 2.89 14.1 4.4 3.20 15.0 3.6 4.17 14.2 4.4 3.23 1 Scroll 2 1.67 400 / 3+N / 50 15 10 0.52 0.2 72 2 1”M 76 62 130 132 Rotary 1 0.71 1 0.89 230/1/50 17 10 0.3 0.08 42 2 3/4”M 73 59 95 97 13 8 0.22 0.08 48 2 3/4”M 72 58 85 87 25 16 0.43 0.18 52 2 1”M 74 61 119 121 CHA/IK/WP 15÷61 CHA/IK/WP 15÷61 1 DIMENSIONS CHA/IK/WP L P H STD STD STD mm mm mm DIMENSIONAL 15 25 41 61 1100 324 700 1200 313 862 1245 354 1245 1245 354 1245 NOTES CLEREANCE AREA (1) CHA/IK/WP 15÷61 A B C D (*) mm mm mm mm 500 500 800 500 (2) (3) (4) (5) (6) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Chilled water from 23 to 18 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Heated water from 30 to 35 °C, ambient air temperature 7 °C d.b./6 °C w.b. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Fan side. 21 1 CHA/CLK 15÷81 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 4 kW TO 20 kW. UNIT DESCRIPTION The COMPACT LINE series, the winning choice for ideal comfort in residential and commercial environments, is enhanced by a new line of products equipped with R410A refrigerant fluid. In addition to the excellence of the range for its compact sizes, quietness and optimised water circuit, the COMPACT LINE series gains another winning feature: R410A refrigerant fluid. High efficiency with reduced heat exchange surfaces compared to those usable with conventional refrigerant fluids and safeguarding the environment thanks to the lower quantities of refrigerant used make the CHA/ CLK range the ideal product for residential and commercial-type applications. Thus increasingly compact and high-tech units, to offer you ideal comfort in all seasons. Particular design features enable immediate and effective use, easy installation and lasting reliability. VERSIONS CHA/CLK Standard unit 22 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman, galvanized sheet and with rubber shock absorbers on the frame. • Rotary/Scroll compressor complete with overload protection embedded in the motor and crankcase, if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser in copper tubes and aluminium finned coil complete with drain pan for heat pump. • Evaporator in AISI 316 stainless steel brazewelded plates type, built-in the storage tank. • R410A refrigerant. • Electrical panel. Includes: main switch with door lock device, fuses, compressor contact and pump contact (41÷71). • Microprocessor control and regulation system. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • Water circuit includes: water differential pressure switch, insulated tank, circulator or pump, safety valve, gauge and expansion vessel inserted in the storage tank. Factory fitted accessories: BT Low water temperature device Loose accessories: PB Low pressure switch CR Remote display IS RS 485 serial interface RP Metallic guards for condenser TECHNICAL DATA R410A CHA/CLK 15÷81 kW kW kW kW kW kW kW kW n° Water circuit Sound power Sound pressure Weights 18 21 25 31 41 51 61 71 81 4.2 1.4 4.3 1.3 5 1.7 4.9 1.6 1 5.1 1.7 5.2 1.6 6 2 5.9 2.0 1 6.4 2.1 6.5 2.0 8 2.6 7.9 2.5 1 7.5 2.5 7.6 2.4 8.7 2.9 8.6 2.8 1 8.6 2.9 8.7 2.8 10.3 3.5 10.2 3.4 1 10.4 3.5 10.5 3.4 12.4 4.2 12.3 4.1 1 12.2 4 12.5 3.7 14.8 4.8 14.5 4.5 1 15.3 5 15.6 4.7 18.8 6.2 18.5 5.9 1 18.6 6 18.9 5.7 21.9 7.1 21.7 6.9 1 20.5 6.6 20.8 6.4 24.4 8 24.2 7.8 1 1 0.97 1 0.97 1 0.82 1 0.82 2 1.94 10 44 0.24 0.2 48 25 3.4 3/4” 78 49 98 123 16 80 0.41 0.2 41 25 3.4 3/4” 80 51 118 143 20 87 0.5 0.21 42 25 3.4 3/4” 81 52 120 145 11 54 0.58 0.3 140 50 3.4 1” 81 52 192 242 2 2 1.78 1.78 400 / 3+N / 50 14 13 64 62 0.73 0.89 0.3 0.3 123 90 50 50 3.4 3.4 1” 1” 81 81 52 52 194 196 244 246 2 1.64 8 39 0.2 0.2 52 25 3.4 3/4” 78 49 96 121 1 1 0.89 0.89 230 / 1 / 50 12 13 63 63 0.31 0.36 0.2 0.2 35 45 25 25 3.4 3.4 3/4” 3/4” 78 78 49 49 106 110 131 135 Rotary n° m³/s V/Ph/Hz A A l/s kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G STD (3) dB(A) STD (4) dB(A) Transport weight Kg Operating weight Kg Scroll 15 78 0.98 0.3 80 50 3.4 1” 81 52 198 248 CHA/CLK 15÷81 Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Compressors Type Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Water flow Pump nominal power Cooling 15 1 DIMENSIONS CHA/CLK L P H STD STD STD mm mm mm 15 18 21 25 31 41 51 61 71 81 870 320 1100 870 320 1100 870 320 1100 870 320 1100 870 320 1100 870 320 1100 1160 500 1270 1160 500 1270 1160 500 1270 1160 500 1270 DIMENSIONAL NOTES CLEREANCE AREA (1) CHA/CLK 15 ÷ 41 51 ÷ 81 15 ÷ 41 A B C D (*) mm mm mm mm 200 200 200 800 (3) CHA/CLK 51 ÷ 81 A B C D (*) mm mm mm mm (2) 200 200 200 800 (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Fan side. 23 1 CHA/K 91÷151 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 25 kW TO 42 kW. UNIT DESCRIPTION The water coolers and heat pumps of the CHA/K 91÷151 AQUALIGHT series, with R410A refrigerant, are intended to satisfy the needs of small and medium domestic and service sector environments. With a peraluman structure, corrosion-resistant over time, these units can be combined with terminal units and, if necessary, the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently without compromises. Available in the versions with or without pumping group, these units are equipped with particular technical and design adjustments that enable an immediate and efficient use, in addition to remarkably quiet operation. A wide range of accessories, all supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA/K Standard unit CHA/K/SP Standard unit with tank and pump 24 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman and galvanized sheet. • Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch and an antifreeze heater for heat pump. • R410A refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system. • Water circuit fos SP version includes: insulated tank, pump, safety valve, gauge and plant expansion vessel. Factory fitted accessories: BT Low water temperature device Loose accessories: CC Condensing control down to -20°C PS Circulating pump CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K 91÷151 kW kW kW kW kW kW kW kW n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Version with tank Storage water volume l and pump Expansion vessel l Water connections ”G Sound power STD (3) dB(A) Sound pressure STD (4) dB(A) Transport weight (5) Kg Weights Operating weight (5) Kg 101 131 151 24.8 8.3 24.6 8.5 30.6 9.7 30.6 9.7 1 28.6 10.7 28.3 11.0 36.7 11.8 36.7 11.8 1 33.4 11.7 33.2 11,9 41.6 12.8 41.6 12.8 1 42.2 14.5 41.9 14,7 55.3 17.3 55.3 17.3 1 1.18 39 1” 1 2.13 1.37 51 1” 2 4.4 1.6 37 1” 2 4.4 2.02 39 1” 2 4.4 23 113 0.55 212 300 8 1” 69 51 220 223 26 122 0.55 169 300 8 1” 69 52 235 238 29 123 0.55 178 300 8 1” 69 52 265 268 44 177 0.75 161 300 8 1” 68 52 279 282 Scroll CHA/K 91÷151 Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Compressors Type Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power Cooling 91 400 / 3+N / 50 1 DIMENSIONS CHA/K L P H STD STD STD mm mm mm DIMENSIONAL 91 101 131 151 1850 1000 1300 1850 1000 1300 1850 1000 1300 1850 1000 1300 NOTES CLEREANCE AREA (1) CHA/K 91 ÷ 151 A (*) B C D mm mm mm mm 800 800 500 800 (2) (3) (4) (5) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. A SIDE: Electrical board side. 25 1 CHA/K/ST 91÷151 Aircooled liquid chillers and heat pumps with axial fans, Scroll compressors, plate EXCHANGERS, PUMP KIT and aqualogik control system. FROM 25 kW TO 42 kW. UNIT DESCRIPTION CHA/K/ST 91÷151 AQUALIGHT series water chillers and heat pumps, with R410A refrigerant gas and AQUALOGIK technology, are designed to meet the needs of small and medium-sized domestic or service sector environments. With a corrosion-resistant peraluman structure, they are combined with terminal units and managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Particular design features enable immediate and effective use, easy installation and lasting reliability. A wide range of accessories, all supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA/K/ST Standard unit with AQUALOGIK technology 26 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman and galvanized sheet. • Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch and an antifreeze heater for heat pump. • R410A refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system with AQUALOGIK technology. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • The hydraulic circuit includes variable speed ciirculation pump, safety valve, gauge and expansion vessel. Factory fitted accessories: BT Low water temperature device Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K/ST 91÷151 Water circuit Sound power Sound pressure Weights kW kW kW kW kW kW kW kW n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Expansion vessel l Water connections ”G STD (3) dB(A) STD (4) dB(A) Transport weight Kg Operating weight Kg 101 131 151 24.8 8.3 24.6 8.5 30.6 9.7 30.6 9.7 1 28.6 10.7 28.3 11.0 36.7 11.8 36.7 11.8 1 33.4 11.7 33.2 11,9 41.6 12.8 41.6 12.8 1 42.2 14.5 41.9 14,7 55.3 17.3 55.3 17.3 1 1.18 39 1” 1 2.13 1.37 51 1” 2 4.4 1.6 37 1” 2 4.4 2.02 39 1” 2 4.4 24 114 0.55 221 5 1” 69 51 230 233 28 123 0.55 181 5 1” 69 52 245 248 31 124 0.75 250 5 1” 69 52 280 283 46 179 0.75 181 5 1” 68 52 294 297 Scroll 400 / 3+N / 50 CHA/K/ST 91÷151 Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Compressors Type Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power Cooling 91 1 DIMENSIONS CHA/K/ST L P H STD STD STD mm mm mm DIMENSIONAL 91 101 131 151 1850 1000 1300 1850 1000 1300 1850 1000 1300 1850 1000 1300 NOTES CLEREANCE AREA (1) CHA/K/ST 91÷151 A (*) B C D mm mm mm mm 800 800 500 800 (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 27 1 CHA/ML/ST 41÷71 AIRCOOLED LIQUID HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGERS AND HYDRONIC KIT. FROM 11 kW TO 22 kW. UNIT DESCRIPTION MIDYLINE is the new line of heat pumps dedicated to air/water for production of hot water up to 60 °C and operations up to -20 °C external air temperature, with Scroll compressors, axial fans and integrated hydronic unit. The unit is designed to singly handle winter heating, summer air conditioning and the production of high temperature hot water, making use of the electrical energy and heat accumulated in the clean air source, free and infinite, which can also transfer heat to homes. Flexibility is the main feature of the MIDYLINE series, which is also combined with heating units and managed by the innovative, intelligent AQUALOGIK control system, optimizing the water setpoint and regulating power supply voltage to the pump and fans, making use of an inertial tank unnecessary. This results in performance with elevated energy efficiency, silent functioning, optimized dimensions and costs. MIDYLINE is also able to operate in extreme conditions where the external air temperature is very low, as well as intelligently managing integrated elements such as furnaces and electrical coils. Based on the external air sensor, the microprocessor activates the single integration elements in the system. VERSIONS CHA/ML/ST Standard unit with AQUALOGIK technology 28 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman, galvanized sheet and with rubber shock absorbers on the frame. • Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch and an antifreeze heater. • R407C refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system with AQUALOGIK technology. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • The hydraulic circuit includes variable speed ciirculation pump, safety valve, gauge and expansion vessel. Factory fitted accessories: EH Integrated electrical coils KC Furnace integration Kit Loose accessories: HW Storage tank for DHW CR Remote display IS RS 485 serial interface RP Metallic guards for condenser TECHNICAL DATA R407C 41M 51M 41T 51T 71 Heating capacity (1) kW Absorbed power (1) kW Heating capacity (2) kW Absorbed power (2) kW Heating capacity (1) kW Heating (EN14511 value) Absorbed power (1) kW Cooling capacity (3) kW Absorbed power (3) kW Cooling Cooling capacity (4) kW Absorbed power (4) kW Cooling capacity (3) kW Cooling (EN14511 value) Absorbed power (3) kW Quantity n° Compressors Type Fans n° Condenser Air flow m³/s Power supply V/Ph/Hz Heating capacity kW Integrated electrical coils Absorbed current A Steps n° Power supply V/Ph/Hz Electrical Max. running current (5) A characteristics Inrush current (5) A Water flow l/s Pump nominal power kW Pump available static press. kPa Water circuit Expansion vessel l Water connections ”G Sound power STD (6) dB(A) Sound pressure STD (7) dB(A) Transport weight Kg Weights Operating weight Kg 11.5 3.2 11.3 2.7 11.9 3.2 7.3 2.5 10.8 2.7 7.0 2.8 1 16 4.6 15.8 3.8 16.4 4.6 10.5 3.6 15.5 4 10.2 3.9 1 16 4.6 15.8 3.8 16.4 4.6 10.5 3.6 15.5 4 10.2 3.9 1 22.5 6.5 22.4 5.4 23.0 6.5 16 5.2 21.2 6.1 15.6 5.6 1 2 1.58 2 1.58 2 1.58 2 1.44 4/6 18/26 2 4/6 18/26 2 11.5 3.2 11.3 2.7 11.9 3.2 7.3 2.5 10.8 2.7 7.0 2.8 1 Scroll 2 1.58 230 / 1 / 50 4/6 18/26 2 4/6 18/26 2 32 160 0.75 0.55 185 2 1” 73 52 208 212 8 40 0.54 0.55 231 2 1” 73 52 205 209 4/6 18/26 2 400 / 3+N / 50 12 64 0.75 0.55 185 2 1” 73 52 208 212 Heating 230 / 1 / 50 23 97 0.54 0.55 231 2 1” 73 52 205 209 16 101 1.07 0.55 156 2 1” 73 52 210 214 CHA/ML/ST 41÷71 CHA/ML/ST 41÷71 1 DIMENSIONS CHA/ML/ST L P H STD STD STD mm mm mm DIMENSIONAL 41M 51M 41T 51T 71 1160 500 1270 1160 500 1270 1160 500 1270 1160 500 1270 1160 500 1270 NOTES CLEREANCE AREA (1) CHA/ML/ST 41÷71 A B C D (*) mm mm mm mm 200 200 200 800 (2) (3) (4) (5) (6) (7) (*) Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Heated water from 30 to 35 °C, ambient air temperature 7 °C d.b./6 °C w.b. Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Chilled water from 23 to 18 °C, ambient air temperature 35 °C. The values between parenthesis refr to the unit with monophase supplying. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Fan side. 29 1 CHA/ML/ST 91÷151 AIRCOOLED LIQUID HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGERS AND HYDRONIC KIT. FROM 31 kW TO 53 kW. UNIT DESCRIPTION MIDYLINE PLUS is the innovative series of heat pumps dedicated to air/water for the production of hot water up to 60 °C operating up to -20 °C outer air temperature, with Scroll compressors, axial fans and integrated hydronic unit. The unit, designed to originate and control – throughout the year - the best comfort conditions in rooms with a high rate of daily attendance, such as enclosed areas destined to the activities of the service sector, autonomously handles winter heating, summer air conditioning and the production of high temperature sanitary hot water. The MIDYLINE PLUS series, designed with an extremely compact structure for simple installation operations, uses only the electric energy and the heat accumulated in the air, to transfer heat to the rooms, thus allowing considerable energy savings, a high rate of reliability and the shortest start-up times. Flexibility is the main feature of the MIDYLINE PLUS series, which is indeed combined with terminal units and managed by the innovative, intelligent AQUALOGIK control and optimization system, which renders the use of an inertial tank unnecessary and guarantees performances with elevated energy efficiency and silent functioning. VERSIONS CHA/ML/ST Standard unit with AQUALOGIK technology 30 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman and galvanized sheet. • Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch and an antifreeze heater. • R407C refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system with AQUALOGIK technology. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • The hydraulic circuit includes variable speed ciirculation pump, safety valve, gauge and expansion vessel. Factory fitted accessories: EH Integrated electrical coils KC Furnace integration Kit Loose accessories: HW Storage tank for DHW CR Remote display IS RS 485 serial interface RP Metallic guards for condenser TECHNICAL DATA R407C 91 101 151 Heating capacity (1) kW Absorbed power (1) kW Heating capacity (2) kW Absorbed power (2) kW Heating capacity (1) kW Heating (EN14511 value) Absorbed power (1) kW Cooling capacity (3) kW Absorbed power (3) kW Cooling Cooling capacity (4) kW Absorbed power (4) kW Cooling capacity (3) kW Cooling (EN14511 value) Absorbed power (3) kW Quantity n° Compressors Type Fans n° Condenser Air flow m³/s Power supply V/Ph/Hz Heating capacity kW Integrated electrical coils Absorbed current A Steps n° Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Water flow l/s Pump nominal power kW Pump available static press. kPa Water circuit Expansion vessel l Water connections ”G Sound power STD (5) dB(A) Sound pressure STD (6) dB(A) Transport weight Kg Weights Operating weight Kg 30.7 8 29.8 6.7 31.4 8.0 20.4 6.6 27.6 7.7 19.8 7.2 1 40.2 10.9 40 9.2 41.1 10.9 28.9 9.3 39.3 10.7 28.2 10.0 1 Scroll 2 4.3 400 / 3 / 50 6/10 26 / 43 2 400 / 3+N / 50 24 127 1.92 0.75 227 5 1” 84 62 235 239 52.6 13.6 50.2 11.4 53.5 13.6 37.3 11.7 47.8 12.8 36.5 12.5 1 Heating 1 2.17 6/10 26 / 43 2 18 99 1.47 0.55 230 5 1” 83 61 220 224 2 4.3 6/10 26 / 43 2 30 167 2.51 1.1 195 5 1” 86 64 265 269 CHA/ML/ST 91÷151 CHA/ML/ST 91÷151 1 DIMENSIONS CHA/ML/ST L P H STD STD STD mm mm mm DIMENSIONAL 91 101 151 1850 1000 1300 1850 1000 1300 1850 1000 1300 NOTES CLEREANCE AREA (1) CHA/ML/ST 91÷151 A (*) B C D mm mm mm mm 800 800 500 800 (2) (3) (4) (5) (6) (*) Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Heated water from 30 to 35 °C, ambient air temperature 7 °C d.b./6 °C w.b. Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Chilled water from 23 to 18 °C, ambient air temperature 35 °C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 31 1 CHA/ML/ST 182-P ÷ 302-P AIRCOOLED LIQUID HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGERS AND HYDRONIC KIT. FROM 57 kW TO 114 kW. UNIT DESCRIPTION MIDYLINE PLUS is the innovative series of heat pumps dedicated to air/water for the production of hot water up to 60 °C operating up to -20 °C outer air temperature, with Scroll compressors, axial fans and integrated hydronic unit. The unit, designed to originate and control – throughout the year - the best comfort conditions in rooms with a high rate of daily attendance, such as enclosed areas destined to the activities of the service sector, autonomously handles winter heating, summer air conditioning and the production of high temperature sanitary hot water. The MIDYLINE PLUS series, designed with an extremely compact structure for simple installation operations, uses only the electric energy and the heat accumulated in the air, to transfer heat to the rooms, thus allowing considerable energy savings, a high rate of reliability and the shortest start-up times. Flexibility is the main feature of the MIDYLINE PLUS series, which is indeed combined with terminal units and managed by the innovative, intelligent AQUALOGIK control and optimization system, which renders the use of an inertial tank unnecessary and guarantees performances with elevated energy efficiency and silent functioning. VERSIONS CHA/ML/ST Standard unit with AQUALOGIK technology 32 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser with copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type with two independent circuits on the refrigerant side and one on the water side, complete with flow switch and an antifreeze heater. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and pump, thermocontacts for fans. • Microprocessor control and regulation system with AQUALOGIK technology. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • The hydraulic circuit includes INVERTER circulation pump, safety valve and expansion vessel. Factory fitted accessories: IM Protection module SL Unit silencement DS Desuperheater KC Furnace integration Kit Loose accessories: HW Storage tank for DHW MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R407C CHA/ML/ST 182-P ÷ 302-P kW kW kW kW kW kW kW kW kW kW kW kW n° n° n° l/s kPa ”G V/Ph/Hz A A n° m³/s dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections ”G Transport weight Kg Operating weight Kg Water circuit Weights 202-P 262-P 302-P 57.2 16.3 55.7 13.7 58.0 16.3 44.3 16.4 60.3 18.7 43.6 17.1 2 78.3 20.8 74.4 17.4 79.2 20.8 60.4 23.6 81.8 27.5 59.6 24.4 2 92.7 25.7 91.1 21.5 93.6 25.7 78.6 34.8 100.8 37.6 77.7 35.7 2 114.2 33.7 111.8 27.1 115.5 33.7 101.0 39.1 129.6 42.2 99.7 40.4 2 2 2 2 2 4.43 11 2”1/2 5.46 15 2”1/2 60 200 1 5.5 87 62 85 60 0.75 110 12 2”1/2 856 875 77 242 2 9.1 89 64 87 62 1.1 135 12 2”1/2 913 935 Scroll 50/100 2.73 10 2”1/2 3.74 12 2”1/2 39 121 1 5.3 84 60 82 58 0.75 150 12 2”1/2 746 755 50 155 1 5.5 85 61 83 59 0.75 130 12 2”1/2 837 855 400 / 3 / 50 CHA/ML/ST 182-P ÷ 302-P Heating capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (1) Heating (EN14511 value) Absorbed power (1) Cooling capacity (3) Absorbed power (3) Cooling Cooling capacity (4) Absorbed power (4) Cooling capacity (3) Cooling (EN14511 value) Absorbed power (3) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Fans Air flow STD version Sound power (5) and with SL Sound pressure (6) accessory SL Sound power (5) SL sound pressure (6) Pump nominal power Heating 182-P 1 DIMENSIONS CHA/ML/ST L P H STD STD STD mm mm mm DIMENSIONAL 182-P 202-P 262-P 302-P 2350 1100 1920 2350 1100 2220 2350 1100 2220 2350 1100 2220 NOTES CLEREANCE AREA CHA/ML/ST 182-P ÷ 302-P A B C (*) D mm mm mm mm 300 1800 800 800 (1) (2) (3) (4) (5) (6) (*) Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Heated water from 30 to 35 °C, ambient air temperature 7 °C d.b./6 °C w.b. Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Chilled water from 23 to 18 °C, ambient air temperature 35 °C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 33 1 MR 50-80 REMOTE HYDRONIC MODULES. FROM 50 lt. AND 80 lt. UNIT DESCRIPTION The remote hydronic modules of the MR 50-80 series are intended to solve technical problems resulting from thermal inertia in air conditioning systems for both residential and industrial use. Installing a tank for cooled water allows units to reduce the operating cycles of the compressors, thus extending the useful life of the machines. It also results in a greater capacity of the system itself, a remarkable operational saving even using machines with reduced capacities and a greater flexibility, being able to work with temperatures other than the design temperatures. The tanks are made in peraluman and zinc-coated plate with a capacity of 50 and 80 litres. VERSIONS MR 50 With 50 lt. tank MR 80 With 80 lt. tank FEATURES • • • • • • 34 Inertial tank Expansion vessel built-in the inertial tank Safety valve Gauge Air vent valve Fitting valves and system drain. TECHNICAL DATA MR 50-80 Weights lt. lt. bar ”G Kg Kg 80 50 3 3 1” 28 78 80 3 3 1” 36 116 MR 50-80 Water volume Expansion vessel Safety valve Water connections Transport weight Operating weight Water circuit 50 1 DIMENSIONS MR L P H STD STD STD mm mm mm 50 80 240 320 1100 340 500 1270 DIMENSIONAL 35 1 CHA/K 182-P÷604-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 47 kW TO 178 kW. UNIT DESCRIPTION The water coolers and heat pumps of the CHA/K 182-P÷604-P AQUAPLUS series, with R410A refrigerant, are intended to satisfy the needs of medium-large service sector or industrial environments. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes; they can be supplied with RS 485 ModBus connection to integrate, if necessary, the innovative monitoring and control system CLIMAFRIEND that allows to program up to 30 different environments in order to obtain a level of comfort intuitively and efficiently without compromises. Equipped with axial fans, Scroll compressors and plate-type exchangers, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA/K Standard unit 36 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser with copper tube and aluminium finned coil. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C BT Low water temperature device DS Desuperheater RT Total heat recovery SI Inertial tank PS Single circulating pump PD Double circulating pump Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K 182-P÷604-P kW kW kW kW kW kW kW kW n° Weights 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 47.6 16.1 47.3 16.4 54.1 17.3 54.1 17.3 2 54.9 18.8 54.5 19.2 61.8 19.6 61.8 19.6 2 63.5 21.8 63.1 22.2 71.4 23.1 71.4 23.1 2 72.9 25 72.4 25.4 80.3 25.4 80.3 25.4 2 83.4 28.3 82.9 28.7 90.4 28.8 90.4 28.8 2 95.9 31.6 95.3 32.3 105.5 33.4 105 33.4 3 110.4 37.9 110 38.5 120.2 38.5 120 38.5 3 126.8 43.3 126 43.9 134.9 43.8 135 43.8 3 147.4 50.1 147 50.9 154.3 50.5 154 50.5 4 177.8 58.2 177 59.2 187 60.4 187 60.3 4 1 1 1 1 1 1 2 3.48 48 1½” 1 3 5.27 46 2½” 6.06 53 2½” 7.04 48 2½” 8.49 48 2½” 56 188 2 7.1 78 60 76 58 0.75 110 400 12 2½” 682 690 832 1232 85 218 2 9.7 79 61 77 59 1.5 140 400 12 2½” 927 940 1082 1482 103 265 2 9.7 79 61 77 59 1.5 120 400 12 2½” 1036 1050 1191 1591 111 243 2 11.4 79 61 77 59 1.5 110 600 18 2½” 1135 1150 1375 1975 133 300 3 15 79 61 77 59 1.85 100 600 18 2½” 1374 1390 1614 2214 Scroll n° n° l/s kPa ”G V/Ph/Hz A A n° m³/s dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Tank water volume l Expansion vessel l Water connections ”G Transport weight (5) Kg Operating weight (5) Kg Transport weight (6) Kg Operating weight (6) Kg Unit with tank and pump. 202-P 2.27 45 1½” 2.62 48 1½” 1 2 3.03 43 1½” 40 163 1 4.8 74 56 72 54 0.75 120 400 12 2½” 595 600 745 1145 43 165 1 4.7 74 56 72 54 0.75 110 400 12 2½” 624 630 774 1174 52 175 2 7.1 78 60 76 58 0.75 110 400 12 2½” 663 670 813 1213 3.98 4.58 43 58 1½” 2½” 400 / 3 / 50 65 75 232 199 2 2 7.3 7.1 78 78 60 60 76 76 58 58 1.1 1.5 140 150 400 400 12 12 2½” 2½” 791 878 800 890 941 1033 1341 1433 2 4 CHA/K 182-P÷604-P Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Fans Air flow STD version Sound power (3) and with SL Sound pressure (4) accessory SL sound power (3) SL sound pressure (4) Pump nominal power Cooling 182-P 1 DIMENSIONS CHA/K L P H STD STD STD mm mm mm 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 2220 2350 1100 2220 2350 1100 2220 2350 1100 2220 3550 1100 2220 3550 1100 2220 DIMENSIONAL NOTES CLEREANCE AREA (1) CHA/K 182-P÷604-P A B C (*) D mm mm mm mm 300 1800 800 800 (2) (3) (4) (5) (6) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. C SIDE: Electrical board side. 37 1 CHA/K/ST 182-P÷604-P Aircooled liquid chillers and heat pumps with axial fans, Scroll compressors, plate EXCHANGERS, PUMP KIT and aqualogik control system. FROM 47 kW TO 178 kW. UNIT DESCRIPTION CHA/K/ST 182-P÷604-P AQUAPLUS series water chillers and heat pumps, with R410A refrigerant gas and AQUALOGIK technology, are designed to meet the needs of medium-large service sector or industrial-type environments. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes. They are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with axial fans, Scroll compressors and plate-type exchangers, they are complete with a hydronic unit. A wide range of accessories, factory-fitted or supplied separately, completes the extreme versatility and functionality of this range. VERSIONS CHA/K/ST Standard unit with AQUALOGIK technology 38 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser with copper tube and aluminium finned coil. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • Microprocessor control and regulation system with AQUALOGIK technology. • The hydraulic circuit includes INVERTER circulation pump, safety valve and expansion vessel. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device DS Desuperheater RT Total heat recovery Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K/ST 182-P÷604-P kW kW kW kW kW kW kW kW n° Weights 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 47.6 16.1 47.3 16.4 54.1 17.3 54.1 17.3 2 54.9 18.8 54.5 19.2 61.8 19.6 61.8 19.6 2 63.5 21.8 63.1 22.2 71.4 23.1 71.4 23.1 2 72.9 25 72.4 25.4 80.3 25.4 80.3 25.4 2 83.4 28.3 82.9 28.7 90.4 28.8 90.4 28.8 2 95.9 31.6 95.3 32.3 105.5 33.4 105 33.4 3 110.4 37.9 110 38.5 120.2 38.5 120 38.5 3 126.8 43.3 126 43.9 134.9 43.8 135 43.8 3 147.4 50.1 147 50.9 154.3 50.5 154 50.5 4 177.8 58.2 177 59.2 187 60.4 187 60.3 4 1 1 1 1 1 1 2 3.48 48 1½” 1 3 5.27 46 2½” 6.06 53 2½” 7.04 48 2½” 8.49 48 2½” 58 190 2 7.1 78 60 76 58 0.75 100 12 2½” 697 705 88 228 2 9.7 79 61 77 59 1.85 125 12 2½” 947 960 105 235 2 9.7 79 61 77 59 1.85 110 12 2½” 1056 1070 116 248 2 11.4 79 61 77 59 1.85 95 18 2½” 1155 1170 141 271 3 15 79 61 77 59 1.85 65 18 2½” 1394 1410 Scroll n° n° l/s kPa ”G V/Ph/Hz A A n° m³/s dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections ”G Transport weight Kg Operating weight Kg Water circuit 202-P 2.27 45 1½” 2.62 48 1½” 1 2 3.03 43 1½” 42 179 1 4.8 74 56 72 54 0.75 120 12 2½” 610 615 45 155 1 4.7 74 56 72 54 0.75 110 12 2½” 639 645 54 177 2 7.1 78 60 76 58 0.75 110 12 2½” 678 685 3.98 4.58 43 58 1½” 2½” 400 / 3 / 50 70 80 199 207 2 2 7.3 7.1 78 78 60 60 76 76 58 58 1.1 1.85 140 130 12 12 2½” 2½” 806 898 815 910 2 4 CHA/K/ST 182-P÷604-P Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Fans Air flow STD version Sound power (3) and with SL Sound pressure (4) accessory SL sound power (3) SL sound pressure (4) Pump nominal power Cooling 182-P 1 DIMENSIONS CHA/K/ST L P H STD STD STD mm mm mm 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 2220 2350 1100 2220 2350 1100 2220 2350 1100 2220 3550 1100 2220 3550 1100 2220 DIMENSIONAL NOTES CLEREANCE AREA CHA/K/ST 182-P÷604-P A B C (*) D mm mm mm mm 300 1800 800 800 (1) (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 39 1 CHA/K 726-P÷36012-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 199 kW TO 1051 kW. UNIT DESCRIPTION MULTIPOWER is an extremely flexible and reliable machine: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system. The machine is equipped with R410A coolant, guaranteeing full adherence to the protocol standards in the Kyoto Treaty (O.D.P.=0) and providing elevated energy efficiency. In fact, this results in heat loads less than 50%, obtaining with MULTIPOWER, EER surpassing any traditional cooler. In this way, the machine can obtain high energy yield with decisively elevated ESEER values, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during nocturnal hours. The use of components built in large series, making them highly reliable, and management of an elevated number of compressors permits increased life span and reduction of machine stopping risks. In fact, a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSIONS CHA/K Standard unit 40 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Evaporator in AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and on the water side, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • Electronic thermostatic valve. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C BT Low water temperature device DS Desuperheater RT Total heat recovery PS Single circulating pump PD Double circulating pump Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K 726-P÷36012-P Unit with pump Weights Cooling capacity (1) Cooling Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow (1) Evaporator Pressure drops (1) Water connections Power supply Electrical Max. running current characteristics Inrush current Sound power (3) STD version and Sound pressure (4) with SL accessory SL sound power (3) SL sound pressure (4) Pump nominal power Weights 786-P 826-P 906-P 1048-P 1128-P 1208-P 199 69 198 70 228 73 228 73 3+3 226 80 225 81 255 83 255 83 3+3 251 85 250 86 283 90 283 90 3+3 276 94 275 95 310 103 310 103 3+3 335 113 334 115 369 121 369 121 4+4 367 122 365 124 401 132 401 132 4+4 403 132 401 134 441 141 441 141 5+5 444 155 442 157 510 164 510 164 5+5 2 2 2 2 304 104 303 105 338 108 338 108 4+4 Scroll 2 2 2 2 9.51 40 3” 10.8 51 3” 11.99 62 3” 13.19 54 3” 16.01 49 3” 19.25 47 3” 21.21 59 3” 158 182 85 66 82 63 3 239 18 100 1654 1670 172 304 85 66 82 63 3 218 18 100 1674 1690 182 311 86 67 83 64 4 290 18 100 1763 1780 203 332 88 69 85 66 4 269 18 100 1961 1980 14.52 50 3” 400 / 3 / 50 224 356 86 67 83 64 5.5 287 18 100 2199 2220 2 8 17.53 59 3” 244 373 88 69 84 65 5.5 274 18 100 2457 2480 265 394 89 70 85 66 5.5 260 18 100 2566 2590 284 416 87 68 84 65 5.5 241 18 100 2610 2640 336 465 89 69 86 66 5.5 214 18 100 3179 3210 n° n° l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections DN Transport weight Kg Operating weight Kg CHA/K 726-P÷36012-P Unit with pump 726-P kW kW kW kW kW kW kW kW n° 6 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 495 170 493 172 564 182 564 182 6+6 546 184 543 186 620 202 620 202 6+6 602 211 599 214 684 223 688 231 6+6 671 243 668 245 776 249 780 257 6+6 751 275 749 277 861 282 864 289 6+6 845 303 842 306 962 312 966 322 6+6 942 336 939 339 1078 349 1082 358 6+6 1051 365 1047 369 1210 383 1215 396 6+6 2 2 2 2 2 2 2 2 23.65 49 3” 26.09 60 3” 28.76 58 3” 40.37 51 6” 45.01 42 6” 50.21 52 6” 367 496 88 68 85 65 5.5 240 18 100 3294 3330 398 527 90 70 87 67 5.5 233 18 100 3463 3500 458 632 94 72 91 69 5.5 224 18 150 3517 3560 667 875 96 73 93 70 11 234 18 150 4518 4580 718 979 96 73 93 70 11 213 18 150 4918 5238 761 1022 97 74 94 71 11 183 18 150 5044 5354 kW kW kW kW kW kW kW kW n° n° n° l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections DN Transport weight Kg Operating weight Kg Scroll 10 32.06 35.88 49 41 6” 6” 400 / 3 / 50 528 602 702 810 95 95 73 73 92 92 70 70 5.5 11 210 253 18 18 150 150 3682 4200 3730 4260 CHA/K 726-P÷36012-P Cooling capacity (1) Cooling Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow (1) Evaporator Pressure drops (1) Water connections Power supply Electrical Max. running current characteristics Inrush current Sound power (3) STD version and Sound pressure (4) SL sound power (3) with SL accessory SL sound pressure (4) Pump nominal power 1 DIMENSIONS CHA/K L P H STD STD STD mm mm mm 726-P 786-P 826-P 906-P 2800 2200 2100 2800 2200 2100 2800 2200 2100 2800 2200 2100 DIMENSIONAL 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 4000 2200 2100 4000 2200 2100 4000 2200 2100 4000 2200 2100 5000 2200 2100 5000 2200 2100 5000 2200 2100 CLEREANCE AREA CHA/K 726-P÷36012-P A mm 500 B mm 1800 C (*) mm 1000 D mm 1800 5000 2200 2100 5000 2200 2100 6200 2200 2100 6200 2200 2100 7200 2200 2100 7200 2200 2100 NOTES (1) (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 41 1 CHA 802÷3204 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SEMI-HERMETIC COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 200 kW TO 720 kW. UNIT DESCRIPTION The water coolers and heat pumps of the CHA 802÷3204 series are intended to satisfy the needs of large-sized service sector or industrial environments. They are used, in combination with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. Equipped with axial fans, semihermetic compressors and tube-bundle exchangers, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. The use of large condensing batteries and fans with high unit efficiency, as well as the optimization of the hydraulic and cooling circuit, combined with a suitable sizing of the user system, allows to obtain high efficiency during operation with remarkably reduced energy consumption. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic compressors type complete with crankcase heater, oil sight glass, incorporated thermal protection and shut off valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C BT Low water temperature device HR Desuperheater HRT/S Total heat recovery in series 42 HRT/P SP PU PD SPU SPD MF RF FE FU FD SS CP Total heat recovery in parallel Inertial tank Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Muffler Cooling circuit shut off valves Evaporator heater Evaporator heater for SPU Evaporator heater for SPD Soft start Potential free contacts Loose accessories: MN High and low gauges MO Compressor oil gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser FP Metallic guards for condenser with filter AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R407C CHA 802÷3204 Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Quantity / Refrigerant circuits kW kW kW kW kW kW kW kW n° Type Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Fans n° Air flow m³/s STD version and Sound power (3) dB(A) dB(A) with SL accessory Sound pressure (4) SL sound power (3) dB(A) SL sound pressure (4) dB(A) Pump nominal power kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel l Water connections DN Transport weight Kg Weights Operating weight Kg CHA 802÷3204 Cooling Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity / Refrigerant circuits kW kW kW kW kW kW kW kW n° Type Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Fans n° Air flow m³/s STD version and Sound power (3) dB(A) dB(A) with SL accessory Sound pressure (4) SL sound power (3) dB(A) SL sound pressure (4) dB(A) Pump nominal power kW kPa Unit with tank and Pump available static press. Storage water volume l pump. Expansion vessel l Water connections DN Transport weight Kg Weights Operating weight Kg 802 902 1002 1102 1202 1502 1602 200 71 199 72 218 73 219 74 2/2 220 77 219 78 238 79 239 81 2/2 246 86 245 87 267 88 268 90 2/2 297 104 296 105 322 107 323 109 2/2 322 112 321 113 346 115 347 117 2/2 360 129 359 130 373 133 374 136 2/2 9,56 37 125 10,51 44 125 11,75 50 125 14,19 32 150 15,38 34 150 17,20 40 150 178 310 4 19,4 91 66 88 63 3,0 160 1100 35 100 2070 2140 178 310 6 18,3 91 66 88 63 3,0 145 1100 35 100 2170 2240 196 341 6 18,3 91 66 88 63 4,0 160 1100 35 100 2210 2280 273 96 272 97 295 99 296 101 2/2 Semi-hermetic 4 13,04 45 125 400 / 3 / 50 256 446 6 29,4 93 68 89 64 4,0 155 2000 80 100 2580 2680 276 456 6 29,4 93 68 89 64 5,5 190 2000 80 100 2715 2860 312 582 8 27,8 93 68 89 64 5,5 185 2000 80 100 2885 3020 320 590 8 30,6 95 70 91 66 5,5 170 2000 80 100 2995 3130 1604 1804 2004 2204 2404 3004 3204 401 143 399 145 435 147 437 151 4/2 439 155 437 157 477 159 479 164 4/2 492 172 490 174 532 176 534 180 4/2 595 206 593 208 635 211 637 215 4/2 644 227 642 229 692 232 694 238 4/2 720 255 718 257 738 260 740 265 4/2 19,16 55 150 20,97 57 150 23,51 48 200 28,43 38 200 30,77 45 200 34,40 42 200 357 488 8 38,9 94 68 90 64 5,5 145 2000 80 125 3650 3780 357 488 10 36,1 94 68 90 64 7,5 170 2000 80 125 3830 3960 393 538 10 36,1 94 68 90 64 7,5 165 2000 80 125 3980 4210 546 190 544 192 590 196 592 200 4/2 Semi-hermetic 4 26,09 41 200 400 / 3 / 50 512 702 10 38,4 96 70 92 66 7,5 160 2000 80 125 4545 4760 547 727 12 45,8 95 69 91 65 7,5 155 2000 80 150 4755 4950 632 902 12 50,0 97 71 93 67 7,5 145 2000 80 150 4855 5050 632 902 12 47,9 97 71 93 67 7,5 140 2000 80 150 5120 5330 CHA 802÷3204 Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) 1 DIMENSIONS CHA L P H STD STD STD mm mm mm 802 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 2404 3004 3204 3350 2200 2100 3350 2200 2100 3350 2200 2100 4400 2200 2100 4400 2200 2100 4400 2200 2100 4400 2200 2100 5550 2200 2100 5550 2200 2100 5550 2200 2100 5550 2200 2100 6700 2200 2100 6700 2200 2100 6700 2200 2100 DIMENSIONAL NOTES CLEREANCE AREA CHA 802÷3204 A (*) mm B mm C mm D mm (1) 1000 1800 500 1800 (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 43 1 CHA 702-V÷5602-V AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 170 kW TO 1500 kW. UNIT DESCRIPTION The water coolers and heat pumps of the CHA 702-V÷5602-V series are intended to satisfy the needs of large-sized service sector or industrial environments. They are used, in combination with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. Equipped with axial fans, screw compressors and tube-bundle exchangers, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. The use of large condensing batteries and fans with high unit efficiency, as well as the optimization of the hydraulic and cooling circuit and the use of latest generation screw compressors, combined with a suitable sizing of the user system, allows to obtain high efficiency during operation with remarkably reduced energy consumption. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors with built-in oil separator, crankcase heater, oil sight glass, thermal protection andintercepting valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement RZ Compressors stepless control CT Condensing control down to 0 °C CC Condensing control down to -20°C BT Low water temperature device HR Desuperheater HRT/S Total heat recovery in series 44 HRT/P SP PU PD SPU SPD RF FE FU FD SS CP Total heat recovery in parallel Inertial tank Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Cooling circuit shut off valve Evaporator heater Evaporator heater for SPU Evaporator heater for SPD Soft start Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser FP Metallic guards for condenser with filter AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R407C CHA 702-V÷5602-V Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Quantity / Refrigerant circuits kW kW kW kW kW kW kW kW n° Type Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Sound power (3) dB(A) STD version and Sound pressure (4) dB(A) dB(A) with SL accessory SL sound power (3) SL sound pressure (4) dB(A) Pump nominal power kW kPa Unit with tank and Pump available static press. Storage water volume l pump. Expansion vessel l Water connections DN Transport weight Kg Weights Operating weight Kg CHA 702-V÷5602-V Cooling Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity / Refrigerant circuits kW kW kW kW kW kW kW kW n° Type Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Sound power (3) dB(A) STD version and Sound pressure (4) dB(A) dB(A) with SL accessory SL sound power (3) SL sound pressure (4) dB(A) Pump nominal power kW kPa Unit with tank and Pump available static press. Storage water volume l pump. Expansion vessel l Water connections DN Transport weight Kg Weights Operating weight Kg 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V 170 67 169 68 190 72 191 73 2/2 198 77 197 78 215 82 216 83 2/2 227 87 226 88 253 92 254 94 2/2 259 97 258 98 280 102 281 105 2/2 290 107 289 108 314 114 316 117 2/2 338 125 337 126 372 132 373 134 2/2 386 141 385 142 417 149 418 152 2/2 433 161 431 162 478 172 480 176 2/2 480 171 479 172 514 179 516 182 2/2 541 189 539 191 585 201 587 206 2/2 8,12 30 125 9,46 34 125 10,85 45 125 12,37 50 125 18,44 36 200 20,69 42 200 22,93 35 200 25,85 42 200 152 324 92 68 89 65 3,0 180 1100 35 100 2120 2190 176 373 92 68 89 65 3,0 160 1100 35 100 2250 2320 190 382 92 68 89 65 3,0 140 1100 35 100 2270 2340 196 409 92 68 89 65 4,0 155 1100 35 100 2380 2450 13,86 16,15 55 25 125 150 400 / 3 / 50 244 272 493 499 94 94 69 69 91 91 66 66 5,5 5,5 165 195 2000 2000 80 80 100 100 2730 3250 2820 3380 312 523 95 70 92 67 5,5 165 2000 80 125 3870 4100 346 694 95 70 92 67 7,5 175 2000 80 125 3930 4160 368 695 95 70 92 67 7,5 170 2000 80 125 4105 4320 450 793 96 71 93 68 7,5 160 2000 80 150 4465 4680 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V 608 212 640 222 642 227 642 227 2/2 687 235 720 245 723 251 723 251 2/2 758 259 809 275 811 280 811 280 2/2 828 281 893 300 896 306 896 306 2/2 910 306 936 313 939 319 939 319 2/2 992 336 1046 350 1049 356 1049 356 2/2 1077 368 1113 380 1116 387 1116 387 2/2 1235 410 1342 430 1346 440 1346 440 2/2 1397 473 1393 477 2/2 1500 504 1595 199 2/2 29,05 46 200 32,82 48 200 36,22 33 200 39,56 36 200 51,46 35 200 59,01 38 200 66.75 43 200 71.67 42 200 554 165 96 68 93 65 7,5 155 2000 80 150 4505 4720 619 12 96 67 93 64 7,5 130 2000 80 150 5045 5240 667 12 96 67 93 64 11,0 165 2000 80 150 5690 5900 741 14 96 67 93 64 11,0 140 2000 80 150 5890 6100 43,48 47,40 40 35 200 200 400 / 3 / 50 779 899 14 14 97 97 68 68 94 94 65 65 11,0 18,5 135 205 2000 2000 80 80 150 200 6240 6940 6450 7240 985 18 97 67 94 64 18,5 200 3000 80 200 7365 7650 1067 18 98 68 95 65 18,5 180 3000 80 200 8360 8780 1016 1604 99 71 96 68 18.5 160 3000 80 200 9240 9660 1082 1640 99 71 96 68 18.5 150 3000 80 200 9750 10230 Screw 6 Screw 6 CHA 702-V÷5602-V Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) 1 DIMENSIONS CHA L L+SP (*) P H 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V STD STD STD STD mm mm mm mm 3350 4400 2200 2100 DIMENSIONAL 3350 4400 2200 2100 3350 4400 2200 2100 3350 4400 2200 2100 4400 5550 2200 2100 4400 5550 2200 2100 5550 5550 2200 2100 5550 5550 2200 2100 5550 5550 2200 2100 6700 6700 2200 2100 6700 6700 2200 2100 7750 7750 2200 2100 8900 8900 2200 2100 10050 10050 2200 2100 10050 10050 2200 2100 10050 10050 2200 2500 12250 12250 2200 2500 13400 13400 2200 2500 13400 13400 2200 2500 NOTES CLEREANCE AREA CHA 702-V÷5602-V A (**) mm B mm C mm D mm 8900 8900 2200 2100 (1) 1000 1800 500 1800 (2) (3) (4) (*) (**) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Length with inertial tank accessory. A SIDE: Electrical board side. 45 1 CHA/K/FC 91÷151 AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 28 kW TO 43 kW. UNIT DESCRIPTION The water coolers of the CHA/K/FC 91÷151 series, with R410A refrigerant, offer innovative technology to meet the needs of systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s Scroll compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. VERSIONS CHA/K/FC Standard unit CHA/K/FC/SP Standard unit with tank and pump 46 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch. • R410A refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Microprocessor control and regulation system. • The hydraulic circuit for SP versions includes: tank, pump, safety valve, gauge and expansion vessel. Factory fitted accessories: PS Single circulating pump BT Low water temperature device Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K/FC 91÷151 Free-cooling cycle Compressors Water circuit Condenser Electrical characteristics Unit with SP accessory Sound pressure Weights Cooling capacity (1) Absorbed power (1) air temperature (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Fans Air flow Power supply Max. running current Inrush current Pump nominal power kW kW °C kW n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G STD (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg 101 131 151 27.9 9.5 -1.7 0.98 1 31.4 11 -2.7 0.98 1 37.3 13.9 0.5 1.96 1 42.8 15.6 -1.2 1.96 1 1.55 117 1” 1 3.33 1.74 142 1” 1 3.33 2.07 132 1” 2 4.44 2.37 141 1” 2 4.03 25 144 0.75 109 150 8 1” 51 415 495 437 667 29 144 1.1 152 150 8 1” 52 430 510 452 682 36 162 1.1 150 150 8 1” 52 470 550 499 729 42 171 1.1 129 150 8 1” 52 485 565 515 745 Scroll 400 / 3+N / 50 CHA/K/FC 91÷151 Cooling 91 1 DIMENSIONS CHA/K/FC L P H STD STD STD mm mm mm DIMENSIONAL 91 101 131 151 1850 900 1840 1850 900 1840 1850 900 1840 1850 900 1840 NOTES CLEREANCE AREA (1) CHA/K/FC 91÷151 A (*) B C D mm mm mm mm 800 800 500 800 (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 47 1 CHA/K/FC 182-P÷604-P AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 53 kW TO 174 kW. UNIT DESCRIPTION The water coolers of the CHA/K/FC 182-P÷604-P series, with R410A refrigerant, offer innovative technology to meet the needs of systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s Scroll compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. VERSIONS CHA/K/FC Standard unit 48 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device SI Inertial tank PS Single circulating pump PD Double circulating pump Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K/FC 182-P÷604-P Free-cooling cycle Compressors Water circuit Condenser Electrical characteristics Unit with tank and pump. Sound pressure Weights Cooling capacity (1) Absorbed power (1) air temperature (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Fans Air flow Power supply Max. running current Inrush current Pump nominal power kW kW °C kW n° 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 52.7 18.1 2.1 2 2 59.5 20.3 1.3 2 2 68.1 23.3 0 2 2 76.7 26.1 -2.4 2 2 85.7 29.3 -3.5 2 2 99.1 36.8 1 6 3 114 42.2 0 6 3 130 48.4 -1.1 6 3 151 54.4 -3 8 4 174 64.9 -4.8 8 4 1 1 1 1 1 1 2 3.96 100 2” 2 8.1 1 3 5.88 135 2”1/2 3 14.7 6.7 145 2”1/2 3 14.7 7.78 102 2”1/2 4 16.7 8.93 106 2”1/2 4 16.7 57 189 1.85 125 400 12 2”1/2 59 57 980 1030 1145 1595 90 223 3 155 400 12 2”1/2 60 58 1317 1400 1512 1995 103 270 3 135 400 12 2”1/2 60 58 1350 1435 1545 2030 116 248 3 165 600 18 2”1/2 61 59 1472 1560 1752 2440 133 300 3 155 600 18 2”1/2 61 59 1510 1600 1790 2480 Scroll n° n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G STD (3) dB(A) SL (3) dB(A) Transport weight (4) Kg Operating weight (4) Kg Transport weight (5) Kg Operating weight (5) Kg 2.72 115 2” 2 8.3 3.07 105 2” 2 8.3 1 2 3.52 120 2” 2 8.3 43 166 1.85 125 400 12 2”1/2 59 57 923 970 1088 1535 46 168 1.85 130 400 12 2”1/2 59 57 932 980 1097 1545 53 176 1.85 115 400 12 2”1/2 59 57 951 1000 1116 1565 4.43 5.09 100 100 2” 2”1/2 2 3 8.1 14.7 400 / 3 / 50 66 84 233 207 1.85 3 115 195 400 400 12 12 2”1/2 2”1/2 59 60 57 58 999 1308 1050 1390 1164 1503 1615 1985 2 4 CHA/K/FC 182-P÷604-P Cooling 182-P 1 DIMENSIONS CHA/K/FC L P H STD STD STD mm mm mm 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 3550 1100 2220 3550 1100 2220 3550 1100 2220 3550 1100 2220 3550 1100 2220 4700 1100 2235 4700 1100 2235 4700 1100 2235 4700 1100 2235 4700 1100 2235 DIMENSIONAL NOTES CLEREANCE AREA CHA/K/FC 182-P÷604-P A B C (*) D mm mm mm mm 800 1800 800 1800 (1) (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. C SIDE: Electrical board side. 49 1 CHA/K/FC 726-P÷36012-P AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 208 kW TO 1102 kW. UNIT DESCRIPTION The water coolers of the CHA/K/FC 726-P÷36012-P MULTIPOWER series, with R410A refrigerant gas, provide advanced technology, flexible and reliable, through an intelligent control module which optimizes the operating times and the powers delivered by the Scroll compressors, according to the needs of the systems, both civil and industrial, where the production of chilled water is required in continuous service throughout the year. During the cold months, in FREE COOLING operating mode, the liquid returning from the system is cooled directly, by way of the forced convection of outside air through the condensing coil, thus reducing the energy required for the scroll compressors operation that the units are equipped with. A system of 3-way valves, controlled by the electronic microprocessor controller that manages the entire unit, can, depending on outside air temperature, operate in the CHILLER, FREE COOLING or MIXED (CHILLER and FREE COOLING at the same time) mode. MULTIPOWER allows the demolition of the inrush currents generated, the elimination of inertial accumulation tanks and an excellent silent functioning, as the fans adjust their speed to the actual load of the system, providing great benefits particularly at night VERSIONS CHA/K/FC Standard unit 50 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Evaporator in AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and on the water side, complete with water differential pressure switch. • Electronic thermostatic valve. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device PS Single circulating pump PD Double circulating pump Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CHA/K/FC 726-P÷36012-P Unit with pump Weights Cooling capacity (1) Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Fans STD version and Air flow with SL accessory Sound pressure (3) SL sound pressure (3) Pump nominal power 826-P 906-P 1048-P 1128-P 1208-P 236 87 -2.8 7 3+3 263 88 -2.5 10.5 3+3 290 98 -0.2 10.5 3+3 328 108 -2.7 14 4+4 Scroll 2 365 123 -3.5 14 4+4 401 132 -1 14 4+4 2 2 2 17.32 112 100 400 / 3 / 50 234 367 8 36.1 69 66 5.5 125 18 100 2990 3190 19.34 106 100 21.21 115 100 23.33 100 100 252 419 8 36.1 70 67 5.5 110 18 100 3020 3220 270 437 8 32.8 70 67 7.5 130 18 100 3220 3470 286 418 8 32.8 70 67 7.5 140 18 100 3510 3770 2 2 2 11.02 102 100 12.38 126 100 13.87 165 100 2 4 15.31 124 100 156 279 4 21.1 66 64 4 155 18 100 2175 2310 168 301 4 21.1 67 64 5.5 165 18 100 2185 2320 185 352 6 27.2 68 65 5.5 115 18 100 2360 2500 202 369 6 26.1 69 66 5.5 140 18 100 2435 2630 13010-P 15010-P 441 147 -2 14 5+5 483 163 -1 17.5 5+5 6 2 25.52 120 100 337 504 10 42.2 71 67 7.5 115 18 100 3920 4250 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 536 179 -2.2 17.5 6+6 590 199 -2.7 17.5 6+6 665 230 -3 17.5 6+6 738 266 -3.5 21 6+6 827 305 -2.5 24.5 6+6 920 340 -0.1 28 6+6 1014 368 0.1 31.5 6+6 1102 412 -0.4 31.5 6+6 2 2 2 2 2 2 2 2 28.28 121 125 31.09 132 125 35.11 148 125 48.52 151 150 53.51 162 150 58.13 173 150 371 538 10 42.2 71 67 11 155 18 125 4180 4520 397 564 10 42.2 71 68 11 135 18 125 4220 4560 466 640 10 45.6 74 70 11 105 18 125 5060 5460 683 891 16 67.8 75 71 18.5 140 18 150 6880 7600 733 994 18 76.1 75 71 18.5 110 18 150 7410 8220 776 1037 18 76.1 76 72 22 100 18 150 7530 8340 kW kW °C kW n° Cooling Weights 786-P 208 76 -2 7 3+3 n° n° l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections DN Transport weight Kg Operating weight Kg CHA/K/FC 726-P÷36012-P Unit with pump 726-P kW kW °C kW n° n° n° l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections DN Transport weight Kg Operating weight Kg Scroll 8 38.89 43.64 152 172 150 150 400 / 3 / 50 530 607 705 815 12 14 50.6 61.7 75 75 71 71 18.5 18.5 180 145 18 18 150 150 5240 5830 5650 6320 CHA/K/FC 726-P÷36012-P Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Fans STD version and Air flow with SL accessory Sound pressure (3) SL sound pressure (3) Pump nominal power 1 DIMENSIONS CHA/K/FC L P H STD STD STD mm mm mm 726-P 786-P 826-P 906-P 4000 2200 2360 4000 2200 2360 4000 2200 2360 4000 2200 2360 DIMENSIONAL 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 5000 2200 2360 5000 2200 2360 5000 2200 2360 5000 2200 2360 6200 2200 2360 6200 2200 2360 6200 2200 2360 CLEREANCE AREA CHA/K/FC 726-P÷36012-P A mm 500 B mm 1800 C (*) mm 1000 D mm 1800 7200 2200 2360 7200 2200 2360 8400 2200 2360 9600 2200 2360 10600 2200 2360 10600 2200 2360 NOTES (1) (2) (3) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 51 1 CHA/FC 642÷2204 AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SEMI-HERMETIC COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 165 kW TO 600 kW. UNIT DESCRIPTION The water coolers of the CHA/FC 642÷2204 series offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s semihermetic compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREECOOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. The product range includes 13 models composed of versions with tank, with pump or with tank and pump. VERSIONS CHA/FC Standard unit FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic compressors type complete with cranckcase heater, oil sight glass, incorporated thermal protection and shut off valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device HRT/P Total heat recovery in parallel SP Inertial tank PU Single circulating pump PD Double circulating pump SPU Inertial tank and single circulating pump SPD Inertial tank and double circulating pump MF Muffler RF Cooling circuit shut off valves SS Soft start CP Potential free contacts Loose accessories: MN High and low gauges MO Compressor oil gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 52 TECHNICAL DATA R407C CHA/FC 642÷2204 Unit with SPU accessory Sound pressure Weights kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections DN STD (3) dB(A) SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg CHA/FC 642÷2204 Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power Unit with SPU accessory Sound pressure Weights kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections DN STD (3) dB(A) SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg 642 702 802 902 1002 1102 1202 165 57.6 5.2 5.9 2 191 59.6 4.2 5.9 2 219 73.5 3.9 5.9 2 241 79.3 3 5.9 2 Semi-hermetic 2 4 12.46 94 100 6 19.17 400 / 3 / 50 168 300 4 108 1100 35 100 66 64 3050 3400 3320 4770 261 86.7 4 7.8 2 300 96.7 2.9 7.8 2 326 106 2.1 7.8 2 2 2 2 8.53 62 100 6 20 9.87 71 100 6 20 11.32 98 100 6 19.17 124 195 4 172 660 24 100 66 64 2730 3075 2930 3935 144 226 4 154 660 24 100 66 64 2830 3165 3080 4075 168 300 4 117 1100 35 100 66 64 3000 3350 3270 4720 2 2 2 13.49 81 100 8 24.44 15.5 72 100 8 24.44 16.85 65 125 8 24.44 186 332 4 109 1100 35 100 66 64 3240 3610 3530 5010 240 430 5.5 146 2000 80 100 66 64 3520 3890 3810 6235 260 440 5.5 145 2000 80 125 66 64 3800 4200 4100 6545 1502 1602 1604 1804 2004 2204 354 114 1.3 7.8 2 363 126 2.3 9.8 2 438 145 0.6 9.8 4 482 157 -0.3 9.8 4 522 167 -1 9.8 4 600 197 0.4 20 4 2 2 2 2 2 2 18.3 92 125 8 24.44 18.76 79 125 10 29.44 22.64 72 125 10 29.44 24.92 81 150 10 29.44 27 90 150 10 29.44 31 79 150 10 40.28 296 567 5.5 113 2000 80 125 66 64 4130 4550 4500 6950 296 567 5.5 124 2000 80 125 67 65 4480 4950 4900 7400 336 468 5.5 108 2000 80 125 67 65 4780 5350 5330 7800 336 468 7.5 129 2000 80 150 67 65 4830 5400 5405 7850 480 670 7.5 113 2000 80 150 67 65 5000 5480 5600 8030 480 670 7.5 106 2000 80 150 71 69 5350 5950 6000 8500 Semi-hermetic 4 400 / 3 / 50 CHA/FC 642÷2204 Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power 1 DIMENSIONS CHA/FC L P H STD STD STD mm mm mm 642 702 802 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 4400 2200 2265 4400 2200 2265 4400 2200 2265 4400 2200 2265 5500 2200 2265 5500 2200 2265 5500 2200 2265 5500 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 DIMENSIONAL NOTES CLEREANCE AREA CHA/FC 642÷2204 A (*) mm B mm C mm D mm (1) 1000 1800 500 1800 (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 53 1 CHA/FC 702-V÷4602-V AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 177 kW TO 1163 kW. UNIT DESCRIPTION The water coolers of the CHA/FC 702-V÷4602-V series offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s semihermetic compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREECOOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. The product range includes 18 models composed of versions with tank, with pump or with tank and pump. VERSIONS CHA/FC Standard unit FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection and hot gas shut off valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device RZ Compressors stepless control HRT/P Total heat recovery in parallel SP Inertial tank PU Single circulating pump PD Double circulating pump SPU Inertial tank and single circulating pump SPD Inertial tank and double circulating pump RF Cooling circuit shut off valves SS Soft start CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 54 TECHNICAL DATA R407C CHA/FC 702-V÷4602-V kW kW °C kW n° n° n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel l Water connections ”G STD (3) dB(A) Sound pressure SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Weights Operating weight (4) Kg Operating weight (5) Kg CHA/FC 702-V÷4602-V Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power kW kW °C kW n° n° n° l/s kPa ”G n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel l Water connections ”G STD (3) dB(A) Sound pressure SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Weights Operating weight (4) Kg Operating weight (5) Kg 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 177 65 0 8 2 199 79 -1.5 8 2 226 87 -2.5 8 2 255 101 -3.3 8 2 329 121 -1 16 2 377 145 -2.5 16 2 423 167 -3.2 16 2 478 173 -2.3 16 2 2 2 2 2 9.15 77 4 4 21.11 10.29 95 4 4 21.11 11.68 110 4 4 21.11 13.18 122 4 4 28.33 153 325 3 163 1100 35 4” 68 65 2620 2750 2800 4100 177 374 3 125 1100 35 4” 68 65 2750 2880 2930 4230 191 383 3 95 1100 35 4” 68 65 2770 2900 2950 4250 197 410 4 148 1100 35 4” 68 65 2800 2950 2980 4300 286 111 -3.2 12 2 Screw 2 6 14.79 112 4 6 32.78 400 / 3 / 50 246 495 5.5 173 2000 80 4” 69 65 2950 3105 3180 5540 2202-V 2402-V 3202-V 3302-V 534 199 -3 20 2 583 215 -3 20 2 656 248 -2.5 24 2 726 283 -3.8 24 2 2 2 2 2 27.61 83 5 10 41.66 30.14 84 6 10 41.66 33.91 130 6 12 51.66 37.53 135 6 12 51.66 453 796 7.5 145 2000 80 6” 71 68 5080 5285 5600 7570 463 557 7.5 141 2000 80 6” 71 68 5110 5415 5630 7700 502 631 11 125 2000 80 6” 71 68 6350 6695 6930 8980 542 671 11 110 2000 80 6” 71 68 6440 6785 7040 9070 2 2 2 2 17.01 45 4 8 32.78 19.49 55 5 8 32.78 21.87 62 5 8 37.22 24.71 83 5 8 41.66 282 509 5.5 205 2000 80 4” 70 67 3920 4075 4280 6360 310 521 5.5 175 2000 80 5” 70 67 4070 4225 4430 6510 344 692 5.5 148 2000 80 5” 70 67 4140 4325 4500 6610 366 693 7.5 152 2000 80 5” 70 67 4810 5015 5230 7300 3402-V 3602-V 4002-V 4202-V 4602-V 795 300 -3.2 28 2 Screw 2 6 41.1 165 6 14 58.33 400 / 3 / 50 612 753 11 65 2000 80 6” 72 69 7190 7535 7820 9820 863 312 -4 28 2 945 334 -3.3 28 2 1036 367 -4.3 28 2 1163 441 -4.2 36 2 2 2 2 2 44.61 176 6 14 58.33 48.85 152 8 14 63.33 53.56 145 8 14 63.33 60.12 203 8 18 81.11 634 783 15 94 2000 80 6” 72 69 7240 7605 7870 9890 660 903 15 113 2000 80 8” 72 69 8250 8720 8950 11005 728 989 15 105 3000 80 8” 72 69 8600 9070 9430 12555 877 1072 22 77 3000 80 8” 72 69 9940 10470 10940 13995 CHA/FC 702-V÷4602-V Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power 1 DIMENSIONS CHA/FC L P H STD STD STD mm mm mm 702-V 802-V 902-V 4400 2200 2360 4400 2200 2360 4400 2200 2360 DIMENSIONAL 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 4400 2200 2360 4400 2200 2360 5550 2200 2360 5550 2200 2360 5550 2200 2360 6700 2200 2360 6700 2200 2360 6700 2200 2360 8900 2200 2360 CLEREANCE AREA CHA/FC 702-V÷4602-V A (*) mm 1000 B mm 1800 C mm 500 D mm 1800 8900 2200 2360 10050 2200 2360 10050 2200 2360 10050 2200 2750 10050 2200 2750 12250 2200 2750 NOTES (1) (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 55 1 CHA/Y 1202-A÷4202-A AIRCOOLED LIQUID CHILLERS, ENERGY CLASS “A” WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS FROM 220 kW TO 924 kW. UNIT DESCRIPTION The CHA/Y 1202-A÷4202-A units in the energy class “A” have EER values greater than 3.1 due to reduced electrical absorption and a high efficiency of the compressor-exchanger combination. Large-sized heat exchangers and highly efficient screw compressors allow to maintain relatively low working pressures (also due to the use of the refrigerant R134a), and all this allows the compressors of the class “A” units to undergo less stress and thus be subject to fewer breakdowns and lower maintenance costs than those installed on traditional units. Furthermore, due to their high efficiency, they can operate at full power with outdoor air temperatures up to 52 °C. Continuous adjustment of the capacity of the compressors and thermostatic expansion valves on the entire series, which allow to reduce the refrigerating capacity to 12% of the total heat load, guarantees the constancy of the water temperature with the system under any condition. Furthermore, the solution of inserting the compressors in an acoustically insulated service space obtained by increasing the sizes of the exchangers, makes these units particularly suitable for installations where reduced energy consumption and extremely quiet operation are essential for the ideal execution of the system. VERSIONS CHA/Y Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection, hot gas shut off valves and stepless capacity steps. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till 0°C. • Operating limit till outside air temperatures up to 52 °C. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement 56 CC BT HR HRT/S HRT/P SP PU PD SPU SPD FE FU FD SS WM CP Condensing control down to -20°C Low water temperature device Desuperheater Total heat recovery in series Total heat recovery in parallel Inertial tank Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Evaporator heater Evaporator heater for SPU Evaporator heater for SPD Soft start Web Monitoring enables remote management of the system through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser FP Metallic guards for condenser with filter AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/Y 1202-A÷4202-A Cooling (EN14511 value) Compressors Evaporator Electrical characteristics STD version and with SL accessory Unit with tank and pump. Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Power supply Max. running current Inrush current Fans Air flow Sound capacity (2) SL sound capacity (2) Sound pressure (3) SL sound pressure (3) Pump nominal power kW kW kW kW n° 1302-A 1502-A 1702-A 1902-A 2002-A 2602-A 3002-A 3602-A 4202-A 220 70 3.14 219 71 3.11 2 245 76 3.22 244 77 3.18 2 297 95 3.13 296 96 3.09 2 341 106 3.22 340 107 3.17 2 394 124 3.18 393 125 3.15 2 432 136 3.18 430 138 3.13 2 535 172 3.11 533 174 3.06 2 652 206 3.17 649 208 3.12 2 808 248 3.26 805 251 3.21 2 924 297 3.11 921 300 3.06 2 2 2 2 2 2 2 2 2 2 10.51 18 125 11.71 33 125 14.19 39 125 16.29 42 125 25.56 46 150 31.15 51 200 38.6 49 200 44.15 52 200 171 246 6 28.3 91 88 68 65 3 180 1100 35 100 3310 3690 3420 4790 171 246 6 28.3 91 88 68 65 4 200 1100 35 100 3190 3590 3330 4690 205 263 6 28.3 91 88 68 65 5.5 230 1100 35 100 3240 3645 3350 4745 229 319 6 30 91 88 68 65 5.5 200 2000 80 125 3630 4070 3740 6070 386 497 10 45.8 93 90 69 66 7.5 170 2000 80 150 4810 5300 5010 7300 477 588 12 55 94 91 69 66 7.5 140 ----150 6760 --7060 --- 555 770 14 73.3 94 91 69 66 11 170 ----200 7700 --8070 --- 587 787 14 73.3 94 91 69 66 11 135 ----200 8060 --8630 --- Screw n° n° l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Storage water volume l Expansion vessel (4) l Water connections DN Transport weight (5) Kg Transport weight (6) Kg Operating weight (5) Kg Operating weight (6) Kg 2 Stepless 18.82 20.64 26 44 150 150 400 / 3 / 50 266 318 341 460 8 8 37.2 39.1 92 92 89 89 68 68 65 65 5.5 7.5 180 190 2000 2000 80 80 125 125 4020 4525 4460 5015 4220 4760 6460 7015 CHA/Y 1202-A÷4202-A Cooling 1202-A 1 DIMENSIONS CHA/Y L P H STD STD STD mm mm mm 1202-A 1302-A 1502-A 1702-A 1902-A 2002-A 2602-A 3002-A 3602-A 4202-A 4400 2200 2100 4400 2200 2100 4400 2200 2100 5550 2200 2100 5550 2200 2100 6700 2200 2100 6700 2200 2100 10050 2200 2100 10050 2200 2100 10050 2200 2100 DIMENSIONAL NOTES CLEREANCE AREA CHA/Y 1202-A÷4202-A A (*) B C D mm mm mm mm 1000 1800 500 1800 (1) (2) (3) (4) (5) (6) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. 24 l water volume for expansion vessel for only pump versions. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 57 1 CHA/Y 1202-B÷6802-B AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 221 kW TO 1597 kW. UNIT DESCRIPTION CHA/Y 1202-B÷6802-B series water chillers and heat pumps, with R134a gas, are designed to meet the needs of large service sector or industrial-type environments. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes. Equipped with axial fans, screw compressors and shell and tube exchangers, they can be completed with a hydraulic circuit with tank, pump, or tank and pump. The use of large condensing coils and high unit efficiency fans, as well as optimisation of the hydraulic and refrigerant circuit and the use of latest-generation screw compressors, combined with a adequate sizing of the user system, ensure high operating efficiency with a considerably reduction in energy consumption. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CHA/Y Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection, hot gas shut off valves and stepless capacity steps. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till 0°C. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement RZ Compressors stepless control 58 CC BT HR HRT/S HRT/P SP PU PD SPU SPD FE FU FD SS WM CP Condensing control down to -20°C Low water temperature device Desuperheater Total heat recovery in series Total heat recovery in parallel Inertial tank Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Evaporator heater Evaporator heater for SPU Evaporator heater for SPD Soft start Web Monitoring enables remote management of the system through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser FP Metallic guards for condenser with filter AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/Y 1202-B÷6802-B kW kW kW kW kW kW kW kW n° n° n° l/s kPa DN V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel (5) l Water connections DN Transport weight Kg Weights Operating weight Kg CHA/Y 1202-B÷6802-B Cooling capacity (1) kW Cooling Absorbed power (1) kW Cooling capacity (1) kW Cooling (EN14511 value) Absorbed power (1) kW Heating capacity (2) kW Heating Absorbed power (2) kW Heating capacity (2) kW Heating (EN14511 value) Absorbed power (2) kW Quantity n° Type Compressors Refrigerant circuits n° Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Sound power (3) dB(A) STD version and Sound pressure (4) dB(A) dB(A) with SL accessory SL sound power (3) SL sound pressure (4) dB(A) Pump nominal power kW kPa Unit with tank and Pump available static press. Storage water volume l pump. Expansion vessel (5) l Water connections DN Transport weight Kg Weights Operating weight Kg 1202-B 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 3002-B 221 80 220 81 225 75 225 75 2 262 88 261 89 255 78 255 78 2 302 112 301 113 289 91 289 91 2 348 137 347 139 338 105 338 105 2 393 156 391 158 390 120 390 120 2 453 167 451 168 457 138 457 138 2 549 197 547 199 536 160 536 160 2 684 231 681 234 662 191 665 197 2 2 2 2 2 2 2 2 2 10.56 50 100 12.52 49 100 14.43 38 125 21.64 43 125 26.23 54 150 32.68 57 150 169 244 88 68 85 65 3 150 1100 35 100 2640 2740 169 244 88 68 85 65 4 170 1100 35 100 2730 2820 203 261 88 68 85 65 5.5 230 1100 35 100 2780 2920 309 451 88 67 85 64 7.5 195 2000 80 125 3800 3930 380 491 90 69 86 65 7.5 165 2000 80 150 4070 4330 464 612 92 69 86 65 7.5 130 2000 80 150 5270 5500 Screw 6 16.63 18.78 50 53 125 125 400 / 3 / 50 227 257 317 332 88 88 68 68 85 85 65 65 5.5 5.5 195 165 1100 1100 35 35 100 125 2920 3120 3060 3250 3602-B 4202-B 4802-B 5402-B 6002-B 6302-B 6802-B 806 284 803 287 767 225 770 231 2 954 334 950 338 850 260 853 266 2 1089 402 1084 407 1044 318 1048 327 2 1218 443 1213 448 1172 350 1176 359 2 Screw 2 6 58.19 55 200 400 / 3 / 50 1050 1425 96 71 92 67 15 150 --80 200 7715 8150 1347 494 1342 499 1306 395 1311 406 2 1475 531 1469 537 1438 418 1443 431 2 1597 554 1589 562 2 2 2 2 38.51 55 200 45.58 53 200 52.03 62 200 530 766 93 70 89 66 11 165 2000 80 150 5480 5770 571 900 93 69 89 65 11 130 2000 80 200 6250 6600 940 1277 94 70 90 66 15 170 --80 200 7255 7710 2 2 2 64.36 55 200 70.47 60 200 76.3 82 250 1194 1687 97 72 93 68 22 200 --80 200 8160 8700 1202 1695 98 73 94 69 22 180 --80 200 8840 9380 1218 1711 100 74 96 70 22 150 --80 200 10100 10620 CHA/Y 1202-B÷6802-B Cooling capacity (1) Cooling Absorbed power (1) Cooling capacity (1) Cooling (EN14511 value) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Heating capacity (2) Heating (EN14511 value) Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Power supply Electrical Max. running current characteristics Inrush current Sound power (3) STD version and Sound pressure (4) with SL accessory SL sound power (3) SL sound pressure (4) Pump nominal power 1 DIMENSIONS CHA/Y L P H STD STD STD mm mm mm 1202-B 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 3002-B 3602-B 4202-B 4802-B 5402-B 6002-B 6302-B 6802-B 3350 2200 2100 3350 2200 2100 3350 2200 2100 3350 2200 2100 4400 2200 2100 5550 2200 2100 5550 2200 2100 6700 2200 2100 6700 2200 2100 7750 2200 2100 10050 2200 2100 10050 2200 2500 10050 2200 2500 11100 2200 2500 13400 2200 2500 DIMENSIONAL CLEREANCE AREA CHA/Y 1202-B÷6802-B A (*) mm 1000 B mm 1800 C mm 500 D mm 1800 NOTES (1) (2) (3) (4) (5) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. 24 l water volume for expansion vessel for only pump versions. A SIDE: Electrical board side. 59 1 CHA/IY/WP 1352÷4402 HEAT PUMPS WITH AXIAL FANS, INVERTER SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 278 kW TO 1133 kW. UNIT DESCRIPTION The aircooled heatpump units of the line CHA/IY/WP 1352÷4402 IDROINVERTER, with refrigerant R134a, are suitable for big sizes installations, such as commercial or industrial buildings. The units are provided with screw compressors with the new technology of INVERTER, axial fans and shell&tube evaporator; as option also with EC axial fans and with inverter regulated circulation pumps. The designed large condensing coils, the high efficiency fans, the optimisation of the water and cooling circuits, the INVERTER screw compressors, allow the units to reach high efficiency in energy class A both in cooling and in heating mode, if combined with a proper sizing of the end-user plant. VERSIONS CHA/IY/WP Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw INVERTER compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection, hot gas shut off valves and stepless capacity steps. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement CC Condensing control down to -20°C BT Low water temperature device EC EC Fans HR Desuperheater 60 HRT/S PUI PDI FE SS WM CP Total heat recovery in series Inverter Single circulating pump Inverter Double circulating pump Evaporator heater Soft start Web Monitoring enables remote management of the system through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/IY/WP 1352÷4402 Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Electrical characteristics STD version and with SL accessory Unit with pump Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Heating capacity (2) Absorbed power (2) COP Heating capacity (2) Absorbed power (2) COP Quantity Type Refrigerant circuits Capacity steps Water flow (1) Pressure drops (1) Water connections (1) Power supply Max. running current Inrush current Fans Air flow kW kW n° n° l/s kPa DN V/Ph/Hz A A n° m³/s Sound power (3) Sound pressure (4) SL sound power (3) SL sound pressure (4) dB(A) dB(A) dB(A) dB(A) Pump nominal power kW kPa l DN Kg Kg kW kW kW kW kW kW n° Pump available static press. Expansion vessel Water connections Transport weight Operating weight 1402 1602 1802 278 89 3.12 277 90 3.08 282 88 3.2 283 89 3.16 2 312 100 3.12 311 101 3.07 323 94 3.44 324 96 3.36 2 366 116 3.16 364 117 3.10 375 111 3.38 377 114 3.30 2 423 133 3.18 421 135 3.13 428 126 3.4 430 129 3.32 2 2 2 2 13.28 33 125 14.91 43 125 17.49 51 150 207 94 6 29.17 92 68 89 65 4 180 35 100 3780 3950 224 98 6 29.17 92 68 89 65 4 165 35 100 3800 3970 262 110 8 38.33 93 68 90 65 5.5 190 35 125 4360 4690 1952 2302 2702 484 564 676 153 177 210 3.16 3.19 3.22 482 562 674 155 179 212 3.11 3.14 3.17 514 570 671 150 164 196 3.43 3.48 3.42 516 572 673 154 168 201 3.34 3.40 3.35 2 2 2 Screw ON/OFF + Screw INVERTER 2 2 2 2 Stepless 20.21 23.12 26.95 32.3 48 48 46 48 150 150 200 200 400 / 3 / 50 287 323 369 436 122 128 159 176 8 10 10 12 40.55 47.77 50.55 61.66 94 94 95 96 69 69 69 70 91 91 92 93 66 66 66 67 5.5 7.5 7.5 7.5 160 180 160 150 80 80 80 80 125 125 150 150 4910 5380 6340 7260 5270 5720 6760 7780 3302 3902 4402 822 258 3.19 819 261 3.14 837 237 3.53 840 243 3.45 2 978 315 3.1 974 319 3.06 1000 277 3.61 1004 286 3.51 2 1133 365 3.1 1128 370 3.05 1148 320 3.59 1153 332 3.47 2 2 2 2 39.27 47 200 46.73 52 200 54.13 64 200 547 232 16 80 97 71 94 68 11 170 80 150 8420 8990 634 274 16 80 97 71 94 68 11 140 80 150 8675 9330 711 324 16 80 98 71 95 68 15 150 80 200 9230 10150 CHA/IY/WP 1352÷4402 Cooling 1352 1 DIMENSIONS CHA/IY/WP L P H STD STD STD mm mm mm 1352 1402 1602 1802 1952 2302 2702 3302 3902 4402 5550 2200 2100 5550 2200 2100 6700 2200 2100 7750 2200 2100 8900 2200 2100 8900 2200 2500 10050 2200 2500 11100 2200 2500 11100 2200 2500 11100 2200 2500 DIMENSIONAL NOTES CLEREANCE AREA CHA/IY/WP 1352÷4402 A (*) B C D mm mm mm mm 1000 1800 500 1800 (1) (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 61 1 CHA/IY/EP 1352÷4402 AIRCOOLED 4 PIPES MULTIFUNCTIONAL UNITS WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 278 kW TO 1133 kW. UNIT DESCRIPTION ENERGYPOWER is the technological and innovative core of the airconditioning and heating CLINT branded plants. The units CHA/ IY/EP 1352÷4402 ENERGYPOWER, with refrigerant R134a, are multi-purpose units with 4-pipes system, with very high efficiency all over the year. Provided with the new technological INVERTER screw compressors, the units reach high EER and ESEER energy values. The range is extremely flexible, due to the advanced logic of the controll system and allows to individually fulfill the heating, cooling and hot water request, as the unit can manage the opposed thermal loads at the same time and reach the highest possible efficiency. The ENERGYPOWER units make the traditional layout of the technical plants easier, because the production of thermal energy for the several users are joint in one unit only; the result is an advantage in terms of installation, maintenance and management and in the meantime of the comfort needs. As option also with EC axial fans and INVERTER screw compressors. VERSIONS CHA/IY/EP Muli use unit 62 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw INVERTER compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection, hot gas shut off valves and stepless capacity steps. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils. • Heat recovery condenser shell and tube, with two indipendent refrigerants circuits and one water circuit. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till 0°C. Factory fitted accessories: IM Protection module SL Unit silencement CC Condensing control down to -20°C BT Low water temperature device EC EC Fans PUI Inverter Single circulating pump PDI Inverter Double circulating pump FE Evaporator heater SS Soft start Web Monitoring enables remote management of the system WM through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. CP Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/IY/EP 1352÷4402 Only Heating Cooling + Heating Compressors Evaporator Heat recovery condenser Electrical characteristics STD version and with SL accessory Unit with pump Weights Cooling capacity (1) Absorbed power (1) EER Heating capacity (2) Absorbed power (2) COP Cooling capacity (3) Heating capacity (3) Absorbed power (3) COP Quantity Type Refrigerant circuits Capacity steps Water flow (1) Pressure drops (1) Water connections (1) Water flow (3) Pressure drops (3) Water connections (3) Power supply Max. running current Inrush current Fans Air flow Sound pressure (4) SL sound pressure (4) Pump nominal power kW kW kW kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections DN Transport weight Kg Operating weight Kg 1402 1602 1802 278 89 3.12 283 86 3.29 276 359 83 7.65 2 312 100 3.12 320 91 3.52 318 404 87 8.3 2 366 116 3.16 375 107 3.5 370 469 99 8.47 2 423 133 3.18 431 122 3.53 429 544 115 8.46 2 2 2 2 13.28 33 100 17.15 34 100 14.91 43 100 19.3 37 100 17.49 51 125 22.41 31 125 207 94 6 29.17 68 65 4 180 35 100 4090 4330 224 98 6 29.17 68 65 4 165 35 100 4110 4460 262 110 8 38.33 68 65 5.5 190 35 125 4820 5280 1952 2302 2702 3302 3902 4402 484 564 676 153 177 210 3.16 3.19 3.22 490 572 672 139 159 190 3.53 3.6 3.54 492 575 686 621 726 865 130 152 179 8.56 8.56 8.66 2 2 2 Screw ON/OFF + Screw INVERTER 2 2 2 2 Stepless 20.21 23.12 26.95 32.3 48 48 46 48 125 125 150 150 25.99 29.67 34.69 41.33 29 28 32 29 125 125 150 150 400 / 3 / 50 287 323 369 436 122 128 159 176 8 10 10 12 40.55 47.77 50.55 61.66 69 69 69 70 66 66 66 67 5.5 7.5 7.5 7.5 160 180 160 150 80 80 80 80 125 125 150 150 5460 5970 6950 8100 5980 6480 7570 8880 822 258 3.19 838 231 3.63 834 1054 220 8.58 2 978 315 3.1 990 271 3.65 996 1261 265 8.52 2 1133 365 3.1 1156 313 3.69 1181 1495 314 8.52 2 2 2 2 39.27 47 150 50.36 32 150 46.73 52 150 60.25 32 150 54.13 64 200 71.43 34 200 547 232 16 80 71 68 11 170 80 150 9340 10200 634 274 16 80 71 68 11 140 80 150 9760 10740 711 324 16 80 71 68 15 150 80 200 10430 11800 CHA/IY/EP 1352÷4402 Only Cooling 1352 1 DIMENSIONS CHA/IY/EP L P H STD STD STD mm mm mm 1352 1402 1602 1802 1952 2302 2702 3302 3902 4402 5550 2200 2100 5550 2200 2100 6700 2200 2100 7750 2200 2100 8900 2200 2100 8900 2200 2500 10050 2200 2500 11100 2200 2500 11100 2200 2500 11100 2200 2500 DIMENSIONAL NOTES CLEREANCE AREA CHA/IY/EP 1352÷4402 A B C (*) D mm mm mm mm 500 1800 1000 1800 (1) (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b. Chilled water from 12 to 7 °C, warm water from 40 to 45 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 63 1 CHA/TTY 1301-1÷5004-2 AIRCOOLED LIQUID CHILLERS WITH AXIALS FANS, TURBOCOR COMPRESSORS (MAGNETIC LEVITATION CENTRIFUGES) AND FLOODED SHELL AND TUBE EXCHANGERS. FROM 248 kW TO 1456 kW. UNIT DESCRIPTION The innovative CHA/TTY 1301-1 ÷ 5004-2 TURBOLINE units, with R134a refrigerant gas, are designed to provide an effective solution to highly selective system needs. Efficiency at partial loads, low inrush currents, an excellent silent functioning, reduced weight and the specific design and handling of every manufacturing aspect make the TURBOLINE series the top unit of CLINT’s design and technical development. The use of TURBOCOR dynamic partialization oil-free magnetic levitation compressors, managed by the TURBOSOFT self-adaptive electronic control, of tube evaporators and innovative heat exchange batteries, traditional or MICROCHANNEL, results in a high energy efficiency, with unequalled ESEER values, in the elimination of accumulation tanks and in an excellent silent functioning. Compared to traditional units, equipped with screw compressors, TURBOLINE units have low operational costs during their entire operating period, even lower than 50%. Besides, the units are equipped with a WEB MONITORING system, for the monitoring and remote management of the units, through the GPRS/GSM/TCP-IP communication protocol. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSIONS CHA/TTY Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in inverter, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of two copper tube and aluminum finned coils or aluminium MICROCHANNEL coils. • Flooded shell and tube type evaporator, with casing with high efficiency tube nest designed for R134a, with one or two independent circuits on the refrigerant side and one on the water side. • R134a refrigerant. • Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermo-contacts for the fans, interface relay and terminals for external connections. • TURBOSOFT control and regulation system is fitted with RS 485 serial interface and Web monitoring device for remote monitoring via GSM/GPRS/TCP-IP network. 64 • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. ACCESSORIES Factory fitted accessories: IM Protection module HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel PU Single circulating pump PD Double circulating pump FE Evaporator heater CP Potential free contacts Loose accessories: CR Remote display RP Metallic guards for condenser FP Metallic guards for condenser with filter AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/TTY 1301-1÷5004-2 Cooling (EN14511 value) Compressors Evaporator Electrical characteristics STD version Unit with pump Weights 1301-1 1401-1 1701-1 2201-1 2601-1 3302-1 4002-1 4302-1 4603-1 248 73 3.4 247 74 3.32 1 282 81 3.48 281 82 3.43 1 335 97 3.45 334 98 3.40 1 403 116 3.47 402 117 3.42 1 627 185 3.39 624 188 3.33 2 770 221 3.48 767 224 3.43 2 929 274 3.39 925 278 3.32 2 1075 311 3.46 1071 214 3.41 3 1 1 1 1 1 1 1 1 11.85 64 100 13.47 40 100 16.01 40 100 19.25 35 125 29.96 56 150 36.79 46 150 44.39 68 150 51.36 46 150 161 36 6 28.3 81 62 3 161 36 6 28.3 81 62 4 161 36 6 31.7 82 62 5.5 239 50 8 38.9 82 62 5.5 509 150 3.39 507 152 3.34 1 Turbocor 1 Stepless 24.32 44 125 400 / 3 / 50 248 59 10 48.3 83 62 7.5 322 190 12 58.9 84 63 7.5 462 230 12 58.9 84 63 11 470 278 14 72.2 84 63 11 692 395 18 88.9 85 63 15 kPa 131 195 230 200 196 159 204 142 210 l DN Kg Kg 18 100 2440 2510 18 100 2440 2510 18 100 2770 2900 18 125 2790 2920 18 125 3590 3730 18 150 4020 4170 18 150 4055 4225 18 150 5710 5910 18 150 6460 6680 4804-1 5004-1 2602-2 3302-2 4002-2 4302-2 4604-2 4804-2 5004-2 1260 362 3.48 1256 366 3.43 4 1456 433 3.36 1450 439 3.31 4 509 145 3.51 507 147 3.46 2 627 185 3.39 624 188 3.33 2 929 274 3.39 925 278 3.32 2 1075 309 3.48 1072 312 3.43 4 1260 362 3.48 1256 366 3.43 4 1456 433 3.36 1450 439 3.31 4 1 1 2 2 2 2 2 2 44.39 68 150 51.36 41 150 60.2 50 200 69.56 59 200 470 294 14 72.2 84 63 11 617 433 18 88.9 85 63 15 626 490 20 102.8 86 64 22 906 601 20 113.3 86 64 22 kW kW kW kW n° n° n° l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) kW CHA/TTY 1301-1÷5004-2 Cooling Cooling (EN14511 value) Compressors Evaporator Electrical characteristics STD version Unit with pump Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Power supply Max. running current Inrush current Fans Air flow Sound capacity (2) Sound pressure (3) Pump nominal power Pump available static press. Expansion vessel Water connections Transport weight Operating weight kW kW n° n° l/s kPa DN V/Ph/Hz A A n° m³/s dB(A) dB(A) kW 60.2 50 200 69.56 59 200 24.32 44 125 29.96 56 150 626 480 20 102.8 86 64 22 906 585 20 113.3 86 64 22 313 166 10 48.3 83 63 7.5 322 200 12 58.9 84 63 7.5 770 221 3.48 767 224 3.43 2 Turbocor 2 Stepless 36.79 46 150 400 / 3 / 50 462 246 12 58.9 84 63 11 kPa 255 220 196 159 204 142 210 255 220 l DN Kg Kg 18 200 7430 7660 18 200 7640 7880 18 125 3700 3845 18 150 4250 4405 18 150 4270 4445 18 150 5820 6030 18 150 6690 6915 18 200 7570 7805 18 200 7850 8095 kW kW n° CHA/TTY 1301-1÷5004-2 Cooling Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Power supply Max. running current Inrush current Fans Air flow Sound capacity (2) Sound pressure (3) Pump nominal power Pump available static press. Expansion vessel Water connections Transport weight Operating weight 1 DIMENSIONS CHA/TTY L P H 1301-1 1401-1 1701-1 2201-1 2601-1 3302-1 4002-1 4302-1 4603-1 4804-1 5004-1 2602-2 3302-2 4002-2 4302-2 4604-2 4804-2 5004-2 STD STD STD mm mm mm 4000 2200 2100 DIMENSIONAL 4000 2200 2100 5000 2200 2100 5000 2200 2100 6200 2200 2100 7200 2200 2100 7200 2200 2100 8400 2200 2500 10050 2200 2500 11100 2200 2500 11100 2200 2500 6200 2200 2100 CLEREANCE AREA CHA/TTY 1301-1÷5004-2 A mm 1800 B mm 500 C mm 1800 D (*) mm 1000 7200 2200 2100 7200 2200 2100 8400 2200 2500 10050 2200 2500 11100 2200 2500 11100 2200 2500 NOTES (1) (2) (3) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 65 1 CHA/Y/FC 1202-B÷6002-B AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 217 kW TO 1460 kW. UNIT DESCRIPTION The water coolers of the CHA/Y/FC 1202-B÷6002-B series, with R134a gas, offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s semihermetic compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREECOOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. The product range includes 13 models composed of versions with tank, with pump or with tank and pump. VERSIONS CHA/Y/FC Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors, with built-in oil separator, suction filter, cranckcase heater, sight glass, thermal protection and hot gas shut off valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device RZ Compressors stepless control HRT/P Total heat recovery in parallel 66 SP PU PD SPU SPD RF SS WM CP Inertial tank Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Cooling circuit shut off valves Soft start Web Monitoring enables remote management of the system through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/Y/FC 1202-B÷6002-B kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel l Water connections DN STD (3) dB(A) Sound pressure SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Weights Operating weight (4) Kg Operating weight (5) Kg CHA/Y/FC 1202-B÷6002-B Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Unit with tank and Storage water volume l pump. Expansion vessel l Water connections DN STD (3) dB(A) Sound pressure SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Weights Operating weight (4) Kg Operating weight (5) Kg 1202-B 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 217 83 -2.5 8 2 258 97 -2 12 2 315 114 -2 12 2 375 148 -4.5 12 2 Screw 2 6 19.38 168 125 6 26.1 400 / 3 / 50 310 663 7.5 115 1100 80 125 69 66 3805 4275 4060 5630 418 157 -3.7 12 2 473 184 -4 16 2 569 210 -3.5 20 2 2 2 2 11.22 125 100 4 21.1 13.34 170 100 6 28.9 16.29 180 100 6 26.1 183 403 4 165 1100 35 100 68 65 3250 3650 3450 4950 192 412 5.5 120 1100 35 100 69 66 3320 3740 3520 5040 232 502 7.5 125 1100 80 100 69 66 3620 4065 3870 5415 2 2 2 21.61 191 125 6 28.7 24.45 130 125 8 34.4 29.42 115 150 10 42.5 546 681 7.5 110 1100 80 125 69 66 4180 4650 4530 6100 440 598 7.5 145 1100 80 125 70 67 4510 4980 4850 6420 449 607 11 185 2000 80 150 71 68 5310 5940 5700 8330 3002-B 3602-B 4202-B 4802-B 5402-B 6002-B 709 263 -4.3 20 2 847 316 -4.3 22 2 994 370 -4.6 22 2 1139 434 -4.7 25 2 1288 490 -4.1 29 2 1460 541 -3.9 36 2 2 2 2 2 2 2 36.65 160 150 10 45.8 43.79 164 150 12 53.9 51.38 160 200 12 57.2 58.88 200 200 14 66.1 66.58 225 200 16 75.6 75.47 300 200 20 94.4 569 709 11 100 2000 80 150 71 68 6820 7450 7420 10050 649 803 15 120 2000 80 150 71 68 7710 8360 8350 11000 784 1012 22 140 2000 80 200 71 68 8605 9400 9410 12205 952 1289 30 160 --80 200 72 69 9590 10210 10550 11170 1071 1446 30 125 --80 200 73 70 10070 10700 10900 11530 1224 1717 37 130 --80 200 75 72 11750 12400 12970 13620 Screw 6 400 / 3 / 50 CHA/Y/FC 1202-B÷6002-B Cooling capacity (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power 1 DIMENSIONS CHA/Y/FC L P H STD STD STD mm mm mm 1202-B 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 3002-B 3602-B 4202-B 4802-B 5402-B 6002-B 4400 2200 2360 4400 2200 2360 4400 2200 2360 4400 2200 2360 5550 2200 2360 5550 2200 2360 6700 2200 2360 10050 2200 2360 10050 2200 2360 10050 2200 2750 10050 2200 2750 11100 2200 2750 13400 2200 2750 DIMENSIONAL CLEREANCE AREA CHA/Y/FC 1202-B÷6002-B A (*) mm 1000 B mm 1800 C mm 500 D mm 1800 NOTES (1) (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 67 1 CHA/TTY/FC 1301-1÷5004-2 AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIALS FANS, TURBOCOR COMPRESSORS (MAGNETIC LEVITATION CENTRIFUGES) AND FLOODED SHELL AND TUBE EXCHANGERS. FROM 246 kW TO 1443 kW. UNIT DESCRIPTION The innovative CHA / TTY / FC 1301-1 ÷ 5004-2 TURBOLINE units, with R134a refrigerant gas, are designed to provide an effective solution to installation requirements of large areas, both commercial and industrial, where the production of chilled water is required in continuous service throughout the year. The unit, designed with specific attention to every aspect of construction and combined with the use of TURBOCOR dynamic partialization oil-free magnetic levitation compressors - managed by the TURBOSOFT self-adaptive electronic control - and with the use of flooded evaporators, achieves a high rate of energy efficiency, with unequalled ESEER values, without using accumulation tanks, and has an excellent silent functioning. Depending on outside air temperature, the microprocessor controller manages the functioning in CHILLER, FREE COOLING or MIXED (both CHILLER and free-cooling) mode. The units are also equipped with a WEB MONITORING system, for the monitoring and remote management of the units through the communication protocol GPRS / GSM / TCP-IP. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSIONS CHA/TTY/FC Standard unit FEATURES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in inverter, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Flooded shell and tube type evaporator, with casing with high efficiency tube nest designed for R134a, with one or two independent circuits on the refrigerant side and one on the water side. • R134a refrigerant. • Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermo-contacts for the fans, interface relay and terminals for external connections. • TURBOSOFT control and regulation system is fitted with RS 485 serial interface and Web monitoring device for remote monitoring via GSM/GPRS/TCP-IP network. 68 • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. ACCESSORIES Factory fitted accessories: IM Protection module HRT/P Total heat recovery in parallel PU Single circulating pump PD Double circulating pump CP Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CHA/TTY/FC 1301-1÷5004-2 CHA/TTY/FC 1301-1÷5004-2 Cooling capacity (1) kW Cooling Absorbed power (1) kW EER air temperature (2) °C Free-cooling cycle Absorbed power (2) kW Quantity n° Type Compressors Refrigerant circuits n° Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Fans n° Condenser Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Pump nominal power kW Unit with tank and Pump available static press. kPa Expansion vessel l pump. Water connections DN Sound capacity (3) dB(A) Sound levels Sound pressure (4) dB(A) Transport weight Kg Weights Operating weight Kg 1301-1 1401-1 1701-1 2201-1 2601-1 3302-1 4002-1 4302-1 4603-1 246 71 3.46 -2.5 10.8 1 281 80 3.51 0.5 10.8 1 333 94 3.54 -2.9 10.8 1 400 116 3.45 0 14.4 1 588 171 3.44 -2.3 21.6 2 696 204 3.41 -0.5 21.6 2 869 257 3.38 -0.2 25.2 2 1046 307 3.41 1 32.4 3 1 1 1 1 12.69 92 100 6 27.2 14.5 97 100 6 27.2 17.18 88 100 6 30.6 20.64 105 125 8 37.5 161 36 4 160 18 100 81 61 3040 3180 161 36 5.5 185 18 100 81 61 3200 3360 161 36 5.5 170 18 100 82 61 3600 3810 239 50 5.5 115 18 125 82 61 3700 3930 495 146 3.39 -2.8 18 1 Turbocor 1 Stepless 25.54 115 125 10 46.4 400 / 3 / 50 248 59 7.5 150 18 125 83 62 4500 4730 4804-1 5004-1 2602-2 3302-2 1229 357 3.44 1 36 4 1443 425 3.4 1 36 4 495 143 3.46 -2.8 18 2 588 171 3.44 -2.3 21.6 2 1 1 2 2 63.42 256 200 20 98.3 74.46 275 200 20 98.3 25.54 115 125 10 46.4 30.34 155 150 12 56.7 626 474 37 190 24 200 86 64 10000 10480 906 582 37 125 24 200 86 64 10300 10790 313 153 7.5 150 18 125 83 63 4700 4930 322 180 11 155 18 150 84 64 5400 5650 1 1 1 1 30.34 155 150 12 56.7 35.91 125 150 12 56.7 44.84 144 150 14 69.4 53.97 220 150 18 85.6 322 180 11 155 18 150 84 63 5150 5400 462 219 11 165 18 150 84 63 5500 5810 470 264 15 135 18 150 84 63 7700 8080 692 395 30 155 18 150 85 63 8800 9250 4002-2 4302-2 4604-2 4804-2 5004-2 696 204 3.41 -0.5 21.6 2 Turbocor 2 Stepless 35.91 125 150 12 56.7 400 / 3 / 50 462 219 11 165 18 150 84 63 5700 6010 869 257 3.38 -0.2 25.2 2 981 280 3.5 1.5 32.4 4 1229 357 3.44 1 36 4 1443 425 3.4 1 36 4 2 2 2 2 44.84 144 150 14 69.4 50.62 188 150 18 85.6 63.42 256 200 20 98.3 74.46 275 200 20 98.3 470 264 15 135 18 150 84 63 7800 8180 617 384 30 190 18 150 85 63 9100 9550 626 474 37 190 24 200 86 64 10200 10680 906 582 37 125 24 200 86 64 10500 10990 CHA/TTY/FC 1301-1÷5004-2 Cooling capacity (1) kW Cooling Absorbed power (1) kW EER air temperature (2) °C Free-cooling cycle Absorbed power (2) kW Quantity n° Type Compressors Refrigerant circuits n° Capacity steps n° Water flow l/s Evaporator Pressure drops kPa Water connections DN Fans n° Condenser Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Pump nominal power kW Unit with tank and Pump available static press. kPa Expansion vessel l pump. Water connections DN Sound capacity (3) dB(A) Sound levels Sound pressure (4) dB(A) Transport weight Kg Weights Operating weight Kg 1 DIMENSIONS CHA/TTY/FC L P H STD STD STD 1301-1 1401-1 1701-1 2201-1 2601-1 3302-1 4002-1 4302-1 4603-1 4804-1 5004-1 2602-2 3302-2 4002-2 4302-2 4604-2 4804-2 5004-2 mm mm mm 4000 2200 2360 DIMENSIONAL 4000 2200 2360 5000 2200 2360 5000 2200 2360 6200 2200 2360 7200 2200 2360 7200 2200 2360 8400 2200 2750 10050 2200 2750 11100 2200 2750 11100 2200 2750 6200 2200 2360 CLEREANCE AREA CHA/TTY/FC 1301-1÷5004-2 A mm 1800 B mm 500 C mm 1800 D (*) mm 1000 7200 2200 2360 7200 2200 2360 8400 2200 2750 10050 2200 2750 11100 2200 2750 11100 2200 2750 NOTES (1) (2) (3) (4) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the Cooling capacity indicated in point (1) is reached. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 69 2 INDEX Aircooled liquid chillers and heat pumps with radial fans. INDEX Page CRA/K 15÷131 CRA/K 182-P÷604-P CRA/K/ST 182-P÷604-P 72 - 73 74 - 75 76 - 77 2 71 2 CRA/K 15÷131 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, ROTARY/SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 4 kW TO 33 kW. UNIT DESCRIPTION The indoor water coolers and heat pumps, of the CRA/K 15÷131 AQUALIGHT series, with R410A refrigerant, are intended to satisfy the needs of small and medium domestic or service sector systems with particular difficulty in positioning units outside the building. With a prepainted plate structure, these units can be combined with terminal units and, if necessary, the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain an optimal level of comfort intuitively and efficiently. Available in the versions with or without pumping group, these units are equipped with particular technical and design adjustments that enable an immediate and efficient use, in addition to remarkably quiet operation and a significant useful head of the fan. A wide range of accessories, all supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CRA/K Standard unit CRA/K/SP Standard unit with tank and pump 72 FEATURES ACCESSORIES • Structure in pre-painted self-supporting frame, in galvanized sheet. • Rotary/Scroll compressors with internal overheat protection and crankcase heater if needed. • Double inlet centrifugal type fan statically and dynamically balanced directly driven by a electric motor (15÷81) or belt driven connected to a three-phase electric motor (91÷131). • Condenser in copper tubes and aluminium finned coil complete with drain pan for heat pump. • Evaporator in AISI 316 stainless steel brazewelded plates type. The evaporator is insulated with flexible closed cells material. On the heat pump units is always installed a water differential pressure switch and an antifreeze heater. • R410A refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch (51÷131). • Microprocessor control and regulation system. • Water circuit SP versions includes: insulated tank, circulator or pump, safety valve, gauge and plant expansion vessel. Factory fitted accessories: BT Low water temperature device Loose accessories: CC Condensing control down to -20°C PS Circulating pump PB Low pressure switch CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CRA/K 15÷131 Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Version with tank and pump Sound power Sound pressure Weights 15 18 21 25 31 41 51 kW kW kW kW kW kW kW kW n° 4.2 1.5 4.2 1.5 5 1.9 5.0 1.9 1 5.1 1.8 5.1 1.85 6 2.2 6.0 2.2 1 6.4 2.2 6.3 2.3 8 2.8 8.0 2.8 1 7.5 2.6 7.4 2.7 8.7 3.1 8.7 3.1 1 8.6 3 8.5 3.1 10.3 3.7 10.3 3.7 1 12.2 4.8 12.1 4.9 14.8 5.6 14.8 5.6 1 l/s kPa ”G n° m³/s Pa V/Ph/Hz A A kW kPa l l ”G dB(A) dB(A) Kg Kg Kg Kg 0.2 18 1” 1 0.94 90 0.24 24 1” 1 0.94 90 0.31 35 1” 1 0.94 80 0.36 20 1” 1 0.94 80 0.41 29 1” 1 0.9 80 10.4 3.6 10.3 3.7 12.4 4.4 12.4 4.4 1 Scroll 0.5 37 1” 1 0.9 80 10 40 0.13 46 50 2 1” 65 49 128 169 129 219 12 46 0.13 40 50 2 1” 65 49 129 170 130 220 14 65 0.2 50 50 2 1” 66 49 134 175 135 225 17 82 0.21 51 50 2 1” 66 51 139 180 140 230 21 89 0.21 42 50 2 1” 67 52 141 182 142 232 CRA/K 15÷131 Cooling Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Version with tank and pump Sound power Sound pressure Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Fans Air flow static pressure Power supply Max. running current Inrush current Pump nominal power static pressure Storage water volume Expansion vessel Water connections STD (3) STD (4) Transport weight (5) Transport weight (6) Operating weight (5) Operating weight (6) Rotary 13 65 0.2 45 50 2 1” 65 49 131 172 132 222 230 / 1 / 50 0.58 35 1” 1 1.92 115 400 / 3+N / 50 11 61 0.3 145 150 5 1” 68 52 200 264 202 414 61 71 81 91 101 131 kW kW kW kW kW kW kW kW n° 15.3 5.8 15.2 5.9 18.8 7 18.8 7.0 1 18.6 6.8 18.5 6.9 21.9 7.9 21.9 7.9 1 20.5 7.4 20.3 7.6 24.4 8.8 24.4 8.8 1 24.8 10 24.6 10.2 30.6 11.4 30.6 11.5 1 28.6 11.9 28.3 12.1 36.7 13 36.7 13.0 1 33.4 13.7 33.2 13.9 41.6 14.8 41.6 14.8 1 l/s kPa ”G n° m³/s Pa V/Ph/Hz A A kW kPa l l ”G dB(A) dB(A) Kg Kg Kg Kg 0.73 23 1” 1 1.89 115 0.89 32 1” 1 1.89 115 0.98 37 1” 1 1.89 115 1.18 39 1” 1 3.17 150 1.37 51 1” 1 3.17 150 1.6 37 1” 1 3.56 160 14 64 0.3 146 150 5 1” 68 52 210 274 212 424 14 61 0.3 123 150 5 1” 69 53 212 276 214 426 15 77 0.3 108 150 5 1” 79 62 214 278 216 428 27 146 0.55 205 150 5 1” 79 62 349 413 352 563 33 151 0.55 182 150 5 1” 79 62 355 420 358 570 36 148 0.55 165 150 5 1” 80 63 370 434 373 584 Scroll 400 / 3+N / 50 CRA/K 15÷131 Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Fans Air flow static pressure Power supply Max. running current Inrush current Pump nominal power static pressure Storage water volume Expansion vessel Water connections STD (3) STD (4) Transport weight (5) Transport weight (6) Operating weight (5) Operating weight (6) 2 DIMENSIONS CRA/K L P H STD STD STD mm mm mm 15 18 21 25 31 41 51 61 71 81 91 101 131 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 690 1725 900 690 1725 900 690 1725 900 690 1725 1500 800 1425 1500 800 1425 1500 800 1425 DIMENSIONAL 15 ÷ 41 51 ÷ 81 NOTES CLEREANCE AREA 91 ÷ 131 (1) CRA/K 15÷41 A (*) mm B mm C mm D mm 800 800 1000 800 CRA/K 51÷81 A (*) mm B mm C mm D mm 800 800 1000 800 CRA/K 91÷131 A mm B mm C mm D (**) mm 800 800 1000 800 (2) (3) (4) (5) (6) (*) (**) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. D SIDE: Electrical board side. 73 2 CRA/K 182-P÷604-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 47 kW TO 178 kW. UNIT DESCRIPTION The indoor water coolers and heat pumps, of the CRA/K 182-P÷604-P AQUAPLUS series, with R410A refrigerant, are intended to satisfy the needs of medium-large services sector or industrial systems with particular difficulty in positioning units outside the building. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes; they can be supplied with RS 485 ModBus connection to integrate, if necessary, the innovative monitoring and control system CLIMAFRIEND that allows to program up to 30 different environments in order to obtain a level of comfort intuitively and efficiently without compromises. Equipped with centrifugal fans, Scroll compressors and plate-type exchangers, even in the version with high head fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CRA/K Standard unit 74 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • Condenser with copper tube and aluminium finned coil. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement CC Condensing control down to -20°C BT Low water temperature device DS Desuperheater RT Total heat recovery SI Inertial tank PS Single circulating pump PD Double circulating pump Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CRA/K 182-P÷604-P Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Electrical characteristics STD version and with SL accessory Unit with tank and pump. Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Power supply Max. running current Inrush current Fans Air flow static pressure Sound power (3) Sound pressure (4) SL sound power (3) SL sound pressure (4) Pump nominal power kW kW kW kW kW kW kW kW n° 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 47.6 17 47.3 17.3 54.1 18.2 54.1 18.2 2 54.9 20.4 54.5 20.8 61.8 21.3 61.8 21.3 2 63.5 24.2 63.1 24.6 71.4 25.5 71.4 25.5 2 72.9 27.4 72.4 27.8 80.3 27.8 80.3 27.8 2 83.4 30.6 82.9 31.0 90.4 31.2 90.4 31.2 2 95.9 33.8 95.3 34.3 106 35.8 105 35.8 3 110 41.9 110 42.6 120 42.5 120 42.5 3 127 47.3 126 47.9 135 47.8 135 47.8 3 147 55 147 55.8 154 55.5 154 55.5 4 178 64.4 177 65.3 187 66.8 187 66.8 4 1 1 1 1 1 1 2 3.48 48 1½” 1 3 5.27 46 2½” 6.06 53 2½” 7.04 48 2½” 8.49 48 2½” 61 193 2 7.1 120 84 66 81 63 0.75 110 400 12 2½” 757 977 765 1377 94 227 2 8.9 135 85 67 82 64 1.5 140 400 12 2½” 991 1216 1005 1616 107 275 2 8.9 135 85 67 82 64 1.5 120 400 12 2½” 1011 1236 1025 1636 122 255 3 11.4 190 86 67 83 64 1.5 130 600 18 2½” 1240 1580 1255 2180 146 313 3 13.9 105 86 67 83 64 1.9 100 600 18 2½” 1354 1694 1370 2294 Scroll n° n° l/s kPa ”G V/Ph/Hz A A n° m³/s Pa dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G Transport weight (5) Kg Transport weight (6) Kg Operating weight (5) Kg Operating weight (6) Kg 2.27 45 1½” 2.62 48 1½” 1 2 3.03 43 1½” 43 166 1 3.3 165 83 65 80 62 0.75 120 400 12 2½” 665 885 670 1285 48 169 1 4.2 147 83 65 80 62 0.75 110 400 12 2½” 674 894 680 1294 57 180 2 7.1 120 84 66 81 63 0.75 110 400 12 2½” 738 958 745 1358 3.98 4.58 43 50 1½” 2½” 400 / 3 / 50 70 80 237 204 2 2 7.3 7.1 105 115 84 85 66 67 81 82 63 64 1.1 1.5 140 150 400 400 12 12 2½” 2½” 781 938 1000 1163 790 950 1400 1563 2 4 CRA/K 182-P÷604-P Cooling 182-P 2 DIMENSIONS CRA/K L P H H (*) STD STD STD STD mm mm mm mm 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 2350 1100 2005 2205 2350 1100 2005 2205 2350 1100 2005 2205 2350 1100 2005 2205 2350 1100 2005 2205 2350 1100 2005 2205 2350 1100 2005 2215 2350 1100 2005 2215 3550 1100 2005 2205 3550 1100 2005 2205 DIMENSIONAL NOTES CLEREANCE AREA (1) CRA/K 182-P÷604-P A (**) B C D mm mm mm mm 800 1800 300 800 (2) (3) (4) (4) (5) (*) (**) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. Height with inertial tank accessory. A SIDE: Electrical board side. 75 2 CRA/K/ST 182-P÷604-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGERS, PUMP KIT AND AQUALOGIK CONTROL SYSTEM. FROM 47 kW TO 178 kW. UNIT DESCRIPTION The indoor water coolers and heat pumps, of the CRA/K/ST 182-P÷604-P AQUAPLUS series, with R410A refrigerant and AQUALOGIK technology are intended to satisfy the needs of medium-large services sector or industrial systems with particular difficulty in positioning units outside the building. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes and are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with centrifugal fans, Scroll compressors and plate-type exchangers, even in the version with high head fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS CRA/K/ST Standard unit with AQUALOGIK technology 76 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • Condenser with copper tube and aluminium finned coil. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -20°C. • Microprocessor control and regulation system with AQUALOGIK technology. • The hydraulic circuit includes INVERTER circulation pump, safety valve and expansion vessel. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device DS Desuperheater RT Total heat recovery Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A CRA/K/ST 182-P÷604-P Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Electrical characteristics STD version and with SL accessory Water circuit Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Power supply Max. running current Inrush current Fans Air flow static pressure Sound power (3) Sound pressure (4) SL sound power (3) SL sound pressure (4) Pump nominal power kW kW kW kW kW kW kW kW n° 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 47.6 17 47.3 17.3 54.1 18.2 54.1 18.2 2 54.9 20.4 54.5 20.8 61.8 21.3 61.8 21.3 2 63.5 24.2 63.1 24.6 71.4 25.5 71.4 25.5 2 72.9 27.4 72.4 27.8 80.3 27.8 80.3 27.8 2 83.4 30.6 82.9 31.0 90.4 31.2 90.4 31.2 2 95.9 33.8 95.3 34.3 106 35.8 105 35.8 3 110 41.9 110 42.6 120 42.5 120 42.5 3 127 47.3 126 47.9 135 47.8 135 47.8 3 147 55 147 55.8 154 55.5 154 55.5 4 178 64.4 177 65.3 187 66.8 187 66.8 4 1 1 1 1 1 1 2 3.48 48 1½” 1 3 5.27 46 2½” 6.06 53 2½” 7.04 48 2½” 8.49 48 2½” 61 193 2 7.1 120 84 66 81 63 0.75 100 12 2½” 772 780 94 227 2 8.9 135 85 67 82 64 1.85 125 12 2½” 1011 1025 107 275 2 8.9 135 85 67 82 64 1.85 110 12 2½” 1031 1045 122 255 3 11.4 190 86 67 83 64 1.85 95 18 2½” 1260 1275 146 313 3 13.9 105 86 67 83 64 1.85 65 18 2½” 1374 1390 Scroll n° n° l/s kPa ”G V/Ph/Hz A A n° m³/s Pa dB(A) dB(A) dB(A) dB(A) kW Pump available static press. kPa Expansion vessel l Water connections ”G Transport weight Kg Operating weight Kg 2.27 45 1½” 2.62 48 1½” 1 2 3.03 43 1½” 43 166 1 3.3 165 83 65 80 62 0.75 120 12 2½” 680 685 48 169 1 4.2 147 83 65 80 62 0.75 110 12 2½” 689 695 57 180 2 7.1 120 84 66 81 63 0.75 110 12 2½” 753 760 3.98 4.58 43 50 1½” 2½” 400 / 3 / 50 70 80 237 204 2 2 7.3 7.1 105 115 84 85 66 67 81 82 63 64 1.1 1.85 140 130 12 12 2½” 2½” 796 958 805 970 2 4 CRA/K/ST 182-P÷604-P Cooling 182-P 2 DIMENSIONS CRA/K/ST L P H STD STD STD 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 3550 1100 2005 3550 1100 2005 mm mm mm DIMENSIONAL NOTES CLEREANCE AREA CRA/K/ST 182-P÷604-P A (*) B C D mm mm mm mm 800 1800 300 800 (1) (2) (3) (4) (*) Chilled water from 12 to 7 °C, ambient air temperature 35 °C. Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 77 3 INDEX Water cooled liquid chillers and heat pumps for remote condensing. INDEX CWW/K 15÷151 CWW/GEO 21÷131 CWW/K 182-P÷604-P CWW/K 726-P÷36012-P CWW 802÷3204 CWW 702-V÷5602-V CWW/Y 1302-B÷9003-B CWW/IY/WP 1352÷4402 CWW/TTY 1801-1÷12806-1 CWW/TTY/DR 1401-1÷6104-1 CWW/CCY 4031÷11682 RCW 6121÷9282 RCW/SL 6122÷9281 RCW/SSL 6132÷9282 MEA/K 15÷151 MEA/K 182-P÷604-P MEA/Y 1302-B÷9003-B RCA/K 4111÷8222 RCA/K/SL 4111÷8222 RCA/K/SSL 5111÷8222 RCA/Y 8141÷9282 RCA/Y/SL 8231÷9252 RCA/Y/SSL 8151÷8272 MR 1500-2500 Page 80 - 81 82 - 83 84 - 85 86 - 87 88 - 89 90 - 91 92 - 93 94 - 95 96 - 97 98 - 99 100 - 101 102 - 103 104 - 105 106 - 107 108 - 109 110 - 111 112 - 113 114 - 115 116 - 117 118 - 119 120 - 121 122 - 123 124 - 125 126 - 127 3 79 3 CWW/K 15÷151 WATER COOLED LIQUID CHILLERS AND HEAT PUMPS WITH ROTARY/SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 4 kW TO 49 kW. UNIT DESCRIPTION The CWW/K 15÷151 AQUALIGHT, with R410A refrigerant, water coolers and heat pumps are intended to satisfy the needs of small and medium domestic or industrial systems which require mediumlow power, space-saving units and quiet operation. In fact, these units are ideal for indoor installation and, equipped with a self-contained structure, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier. These units can be combined with terminal units and, if necessary, the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently without compromises. Equipped with prepainted plate structure, Rotary/Scroll compressors and plate-type exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in the version with tank and pump; and a series of accessories supplied separately rounds off the variety of equipment in this product range. This extremely functional and versatile series includes 14 models with cooling capacities ranging from 4 to 49 kW. VERSIONS CWW/K Standard unit CWW/K/SP Standard unit with tank and pump 80 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Rotary/Scroll compressors with internal overheat protection and crankcase heater if needed. • Condenser in AISI 316 stainless steel brazewelded plates type, with pressostatic valve. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch. • R410A refrigerant. • Electrical pane includes: main switch with door lock device, fuses, compressor and pump remote control switch (51÷151). • Microprocessor control and regulation system. • Water circuit for SP versions complete includes: insulated tank, circulator or pump, safety valve, gauge and expansion vessel. Factory fitted accessories: BT Low water temperature device Loose accessories: PS Circulating pump PB Low pressure switch CR Remote display IS RS 485 serial interface PV Pressure valve and solenoid valve VV Pressure valve and solenoid valve AG Rubber shock absorbers TECHNICAL DATA R410A CWW/K 15÷151 Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Version with tank and pump Sound power Sound pressure Weights 18 21 25 31 41 51 4.6 1.1 4.6 1.2 5.9 1.4 5.1 1.5 1 5.8 1.4 5.7 1.5 7.2 1.7 6.7 1.8 1 7.1 1.8 7.0 2.0 8.8 2.2 8.4 2.5 1 8.3 2 8.2 2.2 10.4 2.5 9.8 2.8 1 9.6 2.3 9.5 2.5 12.5 3 11.9 3.7 1 14.3 3.4 14.2 3.7 17.5 4.3 17.1 4.5 1 l/s kPa ”G l/s kPa ”G V/Ph/Hz A A kW Pump available static press. kPa Expansion vessel l Water connections ”G STD (3) dB(A) STD (4) dB(A) Transport weight Kg Operating weight Kg 0.22 21 1” 0.07 3 1” 0.28 30 1” 0.09 4 1” 0.34 44 1” 0.11 5 1” 0.4 26 1” 0.12 6 1” 0.46 30 1” 0.14 8 1” 11.6 2.9 11.5 3.2 14.9 3.5 13.7 3.8 1 Scroll 0.55 45 1” 0.17 10 1” 7 37 0.2 40 2 1” 51 36 77 78 9 43 0.2 33 2 1” 51 36 78 79 11 62 0.21 38 2 1” 51 36 80 81 12 63 0.21 55 2 1” 51 36 84 85 15 79 0.21 50 2 1” 52 37 87 88 18 86 0.21 35 2 1” 54 39 90 91 0.68 42 1” 0.21 5 1” 400 / 3+ N / 50 8 58 0.3 128 2 1” 54 39 93 95 61 71 81 91 101 131 151 Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Pump nominal power 17.1 4.1 17.0 4.4 20.8 5.4 19.7 5.6 1 20 4.8 19.8 5.2 24.3 6.1 22.5 6.3 1 23 5.5 22.8 6.0 28.4 7 26.3 7.2 1 33.6 7.9 33.3 8.7 39.8 10.1 37.9 10.8 1 39.7 9.3 39.4 10.0 47 11.7 44.5 12.4 1 49.2 11.5 48.8 12.1 59.5 14.4 56.4 15.2 1 0.82 29 1” 0.25 8 1” 0.96 40 1” 0.3 10 1” 1.1 47 1” 0.34 13 1” 1.61 60 1” 0.5 21 1” 1.9 49 1” 0.58 22 1” 2.35 54 1” 0.73 22 1” 10 61 0.3 131 2 1” 55 40 96 98 10 58 0.3 100 2 1” 56 41 98 100 12 74 0.3 93 2 1” 58 43 100 102 27.7 6.8 27.5 7.4 33.8 8.2 31.8 8.9 1 Scroll 1.32 48 1” 0.41 20 1” 400 / 3+ N / 50 23 142 0.55 187 5 1” 58 43 190 193 29 147 0.55 160 5 1” 58 43 198 201 30 142 0.55 131 5 1” 59 44 204 207 30 142 0.75 155 5 1” 59 44 218 221 kW kW kW kW kW kW kW kW n° kW kW kW kW kW kW kW kW n° CWW/K 15÷151 Cooling Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Version with tank and pump Sound power Sound pressure Weights l/s kPa ”G l/s kPa ”G V/Ph/Hz A A kW Pump available static press. kPa Expansion vessel l Water connections ”G STD (3) dB(A) STD (4) dB(A) Transport weight Kg Operating weight Kg Rotary 230/1/50 DIMENSIONS CWW/K L P H STD SP STD STD mm mm mm mm 15 18 21 25 31 41 51 61 71 81 91 101 131 151 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 550 550 1200 550 1100 550 1200 550 1100 550 1200 550 1100 550 1200 550 1100 550 1200 DIMENSIONAL 15 ÷ 151 3 NOTES CLEREANCE AREA SP 91÷151 CWW/K 15÷151 Cooling 15 Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Pump nominal power (1) CWW/K 15÷151 A mm B mm C mm D (*) mm 500 200 500 800 CWW/K/SP 91 ÷ 151 A mm B mm C mm D (*) mm 800 500 800 800 (2) (3) (4) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 15°C to 35°C. Heated water from 40 to 45 °C, water temperature at the evaporator from 15°C to 10°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 81 3 CWW/GEO 21÷131 REVERSIBLE GEOTHERMAL HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 6 kW TO 45 kW. UNIT DESCRIPTION The GEOTHERMIC series reversible heat pumps, designed for domestic and residential use, can provide for winter heating and summer cooling as well as the production of domestic hot water at high temperature (up to 65°C). The unit exploits the renewable energy stored in the ground; a clean and free source available at every latitude and in any season, transferring heat to homes. Powered exclusively by electrical energy, the unit extracts heat stored in the subsoil and releases it in homes, guaranteeing high levels of comfort and efficiency: 75% of the energy used is obtained from the environment. The GEOTHERMIC reversible heat pump is immediately ready upon installation. Optimisation of the hydraulic circuit provides for high efficiency plate-type exchangers and low pressure losses with a circulating pump on the heating system, domestic hot water and geothermic circuits, pressure gauges on the heating system and geothermic circuit, expansion vessel and safety devices on the water side and domestic hot water circuit variable-speed pump for DHW priority storage. GEOTHERMIC is also an integrated system: by means of a controller it monitors the air conditioning system and domestic hot water production, at the same time managing the hydronic terminals and a possible solar panel system. A wide range of accessories supplied separately, completes the extreme versatility and functionality of this range. VERSIONS CWW/GEO Standard unit with domestic hot water production 82 FEATURES ACCESSORIES • Structure manufactured in thick galvanised sheet, painted with epoxy powders complete with rubber shock absorbers. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condensers plate-type in AISI 316 steel, equipped with antifreeze heater. • Evaporator plate-type in AISI 316 steel, equipped with antifreeze heater. • R407C refrigerant. • Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. • Electronic expansion valve thanks to the proportional modulation and high reliability, it guarantees the ability to stabilise and keep heat pump operation constant in very short times, thus offering energy saving. • Water circuit divided into a primary system circuit, domestic hot water circuit and geothermal circuit; comprising the circulating pump, safety water valve and expansion tank. Loose accessories: AI System side inertial tank. KI System hydronic kit HW Storage tank for DHW HWS Storage tank for DHW production for supplement of solar panels. FC Freecooling kit KS Supplementary solar panels kit TECHNICAL DATA R407C CWW/GEO 21÷131 31 51 61 71 91 131 6 1.7 3.53 1.02 48 2 7.1 1.9 3.74 1.22 44 2 10.4 2.7 3.85 1.79 44 4 15.2 3.9 3.9 2.61 48 4 16.4 4.3 3.81 2.82 161 8 20.8 5.5 3.78 3.57 169 8 30.4 7.7 3.95 5.23 136 8 WINTER MODE Heating capacity (1) Absorbed power (1) C.O.P. System water flow static pressure Expansion vessel Heating System side (winter) Cooling capacity in borehole (2) Borehole fluid flowrate (2) Geothermal side (winter) static pressure (2) Expansion vessel SUMMER MODE Cooling capacity (3) Cooling Absorbed power (3) EER System water flow System side static pressure (summer) Expansion vessel Cooling capacity in borehole (4) Borehole fluid flowrate (4) Geothermal side (summer) static pressure (4) Expansion vessel Quantity Compressors Type Heating capacity (5) DHW side Water flow static pressure (5) Power supply Electrical Max. running current characteristics Inrush current Sound pressure STD (6) Weights Transport weight kW kW m³/h kPa lt kW 4.4 5.4 7.9 11.2 12.5 15.7 22.4 m³/h kPa lt 1.26 36 2 1.55 27 2 2.25 31 4 3.21 35 4 3.57 122 8 4.5 150 8 6.42 165 8 kW kW 8.9 1.4 6.36 1.53 27 2 10.5 1.6 6.56 1.8 22 2 15.2 2.3 6.61 2.61 24 4 22.2 3.5 6.34 3.82 25 4 25.1 4 6.28 4.32 80 8 30.4 4.6 6.61 5.23 128 8 44.4 7 6.34 7.64 51 8 m³/h kPa lt kW 10.1 11.8 17 25.1 28.4 34 50.2 m³/h kPa lt n° 1.74 17 2 1 2.03 12 2 1 2.92 16 4 1 4.88 45 8 2 5.85 113 8 2 8.63 142 8 2 kW m³/h kPa V/Ph/Hz A A dB(A) Kg 5.6 0.95 52 6.8 1.17 46 9.9 1.7 45 4.32 10 4 1 Scroll 14.2 2.43 49 19.8 3.41 40 28.3 4.87 148 19 76 41 110 21 102 41 127 11 87 44 175 16 2.75 41 400 / 3+ N / 50 17 101 44 175 18 63 44 187 23 97 47 225 230/1/50 17 61 40 110 DIMENSIONS CWW/GEO L P H STD STD STD mm mm mm DIMENSIONAL 21 31 51 61 71 91 131 600 450 920 600 450 920 600 550 1060 600 550 1060 800 680 1180 800 680 1180 800 680 1180 (1) CWW/GEO 21 ÷ 61 mm mm mm mm 1907 400 500 400 CWW/GEO 71 ÷ 131 A B C (*) D mm mm mm mm 3 NOTES CLEREANCE AREA A B C (*) D CWW/GEO 21÷131 21 300 400 600 400 (2) (3) (4) (5) (6) (*) User circuit: radiant system °C 30/35 In-Out. External circuit: geothermal borehole glycolate water 20 % °C 0/-3 In-Out User circuit: radiant system °C 23/18 In-Out External circuit: geothermal borehole glycolate water 20 % °C 25/30 In-Out. DHW circuit °C 45/50 In-Out. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 83 3 CWW/K 182-P÷604-P WATER COOLED LIQUID CHILLERS AND HEAT PUMPS WITH SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 55 kW TO 195 kW. UNIT DESCRIPTION The CWW/K 182-P÷604-P AQUAPLUS, with R410A refrigerant, water coolers and heat pumps are intended to satisfy the needs of small and medium domestic or industrial systems which require medium-low power, space-saving units and quiet operation. In fact, these units are ideal for indoor installation and, equipped with a self-contained structure, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier. These units can be combined with terminal units and, if necessary, the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently without compromises. Equipped with prepainted plate structure, Scroll compressors and plate-type exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in the version with tank and pump; and a series of accessories supplied separately, like desuperheater and total heat recovery, rounds off the variety of equipment in this product range. This extremely functional and versatile series includes 10 models with cooling capacities ranging from 55 to 195 kW. VERSIONS CWW/K Standard unit 84 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device DS Desuperheater RT Total heat recovery Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface SPU Additional module with inertial tank and single circulating pump SPD Additional module with inertial tank and double circulating pump PV2 2-ways pressostatic valve PV3 3-ways pressostatic valve AG Rubber shock absorbers TECHNICAL DATA R410A CWW/K 182-P÷604-P Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Pump nominal power 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 55.4 12.8 55.0 13.6 72.5 18 66.5 18.7 2 62.5 14.3 62.1 15.3 80.1 20 73.5 20.7 2 72.1 16.6 71.6 17.6 93.3 23.2 86.6 24.2 2 82.5 18.7 82.0 19.8 105 25.7 98.7 27.6 2 97.2 21.8 96.7 22.9 121 28.8 110 29.8 2 112 25.7 111 27.3 140 33.2 126 34.6 3 130 28.5 129 29.9 159 38.4 143 39.5 3 149 32.8 148 34.3 180 42.7 170 44.9 3 170 37.7 169 39.3 205 51.7 184 50.8 4 195 43.7 194 45.6 237 56.7 223 58.2 4 1 1 1 1 1 1 2 3.94 51 1”1/4 4.84 43 2”1/2 1 3 6.23 53 2”1/2 7.59 36 2”1/2 7.14 59 2”1/2 8.71 39 2”1/2 8.12 49 2”1/2 9.92 43 2”1/2 9.33 48 2”1/2 11.41 48 2”1/2 52 184 1.1 135 300 12 2” 1/2 73 52 68 52 423 643 435 955 77 210 1.5 120 300 12 2” 1/2 74 52 69 52 658 888 680 1210 91 258 1.5 110 300 12 2” 1/2 76 54 71 54 681 911 705 1235 103 235 1.85 120 300 12 2” 1/2 76 54 71 54 767 997 790 1320 121 288 18.5 100 300 12 2” 1/2 77 55 72 55 803 1033 830 1360 kW kW kW kW kW kW kW kW n° Scroll n° n° l/s Evaporator kPa ”G l/s Condenser kPa ”G V/Ph/Hz Electrical A characteristics A kW Pump available static press. kPa Version with tank Storage water volume l and pump Expansion vessel l Water connections ”G STD (3) dB(A) Sound power SL (3) dB(A) STD (4) dB(A) Sound pressure SL (4) dB(A) Transport weight (5) Kg Transport weight (6) Kg Weights Operating weight (5) Kg Operating weight (6) Kg 2.65 54 1”1/4 3.26 47 1”1/4 2.99 48 1”1/4 3.67 51 1”1/4 1 2 3.44 49 1”1/4 4.24 52 1”1/4 38 161 0.75 105 300 12 2” 1/2 71 50 66 50 384 604 390 910 41 163 0.75 110 300 12 2” 1/2 72 51 67 51 393 613 400 920 48 171 0.75 100 300 12 2” 1/2 72 51 67 51 411 631 420 940 4.64 5.38 44 57 2”1/2 2”1/2 5.69 6.6 46 54 2”1/2 2”1/2 400 / 3 / 50 61 71 228 195 1.1 1.5 120 130 300 300 12 12 2” 1/2 2” 1/2 74 74 53 52 69 69 53 52 453 622 673 842 470 640 990 1160 2 4 DIMENSIONS CWW/K L L (STD+SPU) L (STD+SPD) P H STD STD STD STD STD mm mm mm mm mm DIMENSIONAL 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 (1) CWW/K 182-P÷604-P mm mm mm mm 3 NOTES CLEREANCE AREA A B C (*) D CWW/K 182-P÷604-P Cooling 182-P 1907 300 800 300 (2) (3) (4) (5) (6) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Hot water from 40° to 45°C. Well water from 15 to 10°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. C SIDE: Electrical board side. 85 3 CWW/K 726-P÷36012-P WATER COOLED LIQUID CHILLERS AND HEAT PUMPS WITH SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 224 kW TO 1242 kW. UNIT DESCRIPTION The CWW/K 726-P÷36012-P MULTIPOWER series water chillers and heat pumps, with R410A refrigerant, are intended to satisfy the needs of small and medium domestic or industrial systems which require medium-low power, space-saving units and quiet operation. In fact, these units are ideal for indoor installation and, equipped with a self contained structure, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier. MULTIPOWER is an extremely flexible and reliable machine: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system and providing elevated energy efficiency. In fact, this results in heat loads less than 50%, obtaining with MULTIPOWER, EER surpassing any traditional cooler. In this way, the machine can obtain high energy yield with decisively elevated ESEER values, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during nocturnal hours. The use of components built in large series, making them highly reliable, and management of an elevated number of compressors permits increased life span and reduction of machine stopping risks. In fact, a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSIONS CWW/K Standard unit 86 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser in AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and on the water side. • Evaporator in AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and on the water side, complete with water differential pressure switch. On the heat pump units is always installed an antifreeze heater. • Electronic thermostatic valve. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device DS Desuperheater RT Total heat recovery Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface PV2 2-ways pressostatic valve PV3 3-ways pressostatic valve AG Rubber shock absorbers TECHNICAL DATA R410A CWW/K 726-P÷36012-P Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights 726-P 786-P 826-P 906-P 1048-P 1128-P 1208-P kW kW kW kW kW kW kW kW n° 224 52 223 54.6 290 66 263 68.3 6 250 57 249 59.9 320 74 290 79.1 6 274 63 273 66.4 349 80 316 83.2 6 308 70 307 73.6 394 88 356 91.3 6 383 86 381 89.6 484 111 437 114 8 422 95 420 99.3 534 119 481 123 8 462 104 460 109 584 135 528 140 10 509 115 507 121 640 144 578 149 10 n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) Kg Kg 2 2 2 2 345 78 343 81.8 437 101 395 104 8 Scroll 2 2 2 2 10.7 54 80 13.19 70 80 11.94 51 80 14.67 74 80 13.09 56 80 16.10 81 80 14.72 56 80 18.06 76 80 18.3 47 80 22.41 59 80 22.07 60 80 27.04 75 80 24.32 57 80 29.81 76 80 141 265 86 82 62 58 1047 1080 154 286 87 83 64 60 1103 1140 163 330 88 84 65 61 1123 1160 180 347 89 85 65 61 1159 1200 16.48 60 80 20.21 67 80 400 / 3 / 50 205 338 89 85 65 61 1352 1400 2 8 20.16 52 80 24.70 65 80 223 390 90 86 66 62 1422 1480 240 407 90 86 66 62 1442 1500 256 389 90 86 66 62 1642 1700 300 467 91 87 67 63 1730 1800 CWW/K 726-P÷36012-P Cooling Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (3) SL (3) STD (4) SL (4) Transport weight Operating weight 6 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P kW kW kW kW kW kW kW kW n° 562 129 559 135 710 164 642 170 12 622 144 619 151 783 181 707 187 12 696 157 693 164 874 203 789 209 12 786 176 783 183 986 224 890 230 12 895 204 891 213 1113 259 1005 267 12 1015 230 1011 239 1255 289 1133 297 12 1129 261 1124 273 1391 321 1258 331 12 1242 287 1236 301 1531 357 1385 368 12 n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) Kg Kg 2 2 2 2 2 2 2 2 26.85 70 80 33.01 70 80 29.72 59 80 36.60 77 80 33.25 60 150 40.75 60 150 48.49 61 150 59.48 61 150 53.94 70 150 66.41 70 150 59.34 79 150 73.05 78 150 334 501 91 87 67 63 1930 2000 360 527 92 88 68 63 1968 2050 429 604 96 92 71 67 2806 2900 626 834 98 94 73 69 3558 3700 668 929 99 95 74 70 3658 3800 710 971 99 95 74 70 3708 3850 Scroll 10 37.55 42.76 53 66 150 150 45.98 52.51 53 65 150 150 400 / 3 / 50 486 556 661 764 97 98 93 94 72 73 68 69 2884 3184 3000 3300 DIMENSIONS CWW/K L P H STD STD STD mm mm mm 726-P 786-P 826-P 906-P 2500 800 1900 2500 800 1900 2500 800 1900 2500 800 1900 DIMENSIONAL 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 3000 800 1900 3000 800 1900 3000 800 1900 3550 800 1900 3550 800 1900 4000 800 1900 4000 800 1900 CLEREANCE AREA CWW/K 726-P÷36012-P A mm 500 B mm 500 C (*) mm 800 D mm 500 4650 1350 1900 4650 1350 1900 4650 1350 1900 4650 1350 1900 4650 1350 1900 CWW/K 726-P÷36012-P Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (3) SL (3) STD (4) SL (4) Transport weight Operating weight 3 4650 1350 1900 NOTES (1) (2) (3) (4) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Hot water from 40° to 45°C. Well water from 15 to 10°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 87 3 CWW 802÷3204 WATER COOLED LIQUID CHILLERS WITH SEMI-HERMETIC COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 218 kW TO 782 kW. UNIT DESCRIPTION The water coolers of the CWW 802÷3204 series are intended to satisfy the needs of the services sector or industrial systems requiring high power, thus making it convenient to split the workload over several compressors. Equipped with semihermetic compressors, tube-bundle exchangers and connections for condensation with tower water or well water or with a dry-cooler, they have a series of accessories which are factoryassembled of supplied separately such as: heat recuperator in series or in parallel, soft start and, if necessary, a device for operating a heat pump. Designed and produced to optimize the layout of each component so as to make any necessary maintenance operations more convenient, these units have an essential and compact structure intended for indoor installation. This extremely functional and versatile series includes 14 models with cooling capacities ranging from 218 to 782 kW. VERSIONS CWW Standard unit 88 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic compressors type complete with cranckcase heater, oil sight glass, incorporated thermal protection and shut off valves. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. Each refrigerant circuit is supplied with an indipendent condenser. Water connections for well water or closed circuit. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device HR Desuperheater HRT Total heat recovery MF Muffler RF Cooling circuit shut off valves FE Evaporator heater SS Soft start DP Device for heat pump operation CP Potential free contacts Loose accessories: MN High and low gauges MO Compressor oil gauges CR Remote display IS RS 485 serial interface PV3 3-ways pressostatic valve AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R407C CWW 802÷3204 Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power STD with SL accessory (2) Sound pressure STD (3) STD with SL accessory (3) Transport weight Operating weight Weights kW kW kW kW n° n° n° l/s kPa DN l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) Kg Kg CWW 802÷3204 Cooling Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) STD with SL accessory (2) Sound pressure STD (3) STD with SL accessory (3) Transport weight Operating weight Weights 802 902 1002 1102 1202 1502 1602 218 59 217 61 2 237 64 236 66 2 266 69 265 71 2 321 85 320 87 2 348 91 347 94 2 390 105 389 108 2 2 2 2 10.42 29 100 13.23 45 2” 11.32 34 100 14.38 52 2” 12.71 21 125 16.01 44 2”½ 167 299 87 84 65 62 1290 1380 167 299 87 84 65 62 1330 1420 185 330 87 84 65 62 1370 1500 294 76 293 78 2 Semi-hermetic 2 4 14.05 26 125 17.68 44 2”½ 400 / 3 / 50 240 430 87 84 65 62 1575 1710 2 2 2 15.34 31 125 19.4 43 2”½ 16.63 35 125 20.97 50 2”½ 18.63 37 125 23.65 46 2”½ 260 440 88 85 66 63 1595 1730 296 566 88 85 66 63 1615 1755 296 566 88 85 66 63 1660 1790 1604 1804 2004 2204 2404 3004 3204 kW kW kW kW n° 436 118 434 122 4 474 128 472 131 4 532 136 530 14 4 641 169 638 169 4 697 183 695 183 4 782 209 779 209 4 n° n° l/s kPa DN l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) dB(A) dB(A) Kg Kg 2 2 2 2 2 2 20.83 45 150 26.47 59 2”½ 22.65 32 150 28.76 40 DN80 25.42 51 150 32.01 46 DN80 30.63 61 200 38.7 54 DN80 33.3 43 200 42.04 46 DN80 37.36 45 200 47.35 50 DN80 335 466 89 86 66 63 2390 2580 335 466 89 86 66 63 2465 2660 371 516 89 86 66 63 2480 2675 588 152 586 152 4 Semi-hermetic 2 4 28.09 52 200 35.36 43 DN80 400 / 3 / 50 480 670 89 86 66 63 3100 3400 520 700 90 87 67 64 3150 3465 592 862 90 87 67 64 3200 3500 592 862 90 87 67 64 3220 3520 DIMENSIONS CWW L P H STD STD STD mm mm mm 802 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 2404 3004 3204 3100 780 1700 3100 780 1700 3100 780 1700 3100 780 1700 3100 780 1700 3100 780 1700 3100 780 1700 3100 1420 1900 3100 1420 1900 3100 1420 1900 3100 1420 1900 3100 1420 1900 3100 1420 1900 3100 1420 1900 DIMENSIONAL CWW 802÷3204 Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) 3 NOTES CLEREANCE AREA (1) CWW 802÷1602 A mm B mm C mm D (*) mm 500 500 500 800 CWW 1604÷3204 A mm B mm C (**) mm D mm 500 500 800 500 (2) (3) (*) (**) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. C SIDE: Electrical board side. 89 3 CWW 702-V÷5602-V WATER COOLED LIQUID CHILLERS WITH SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 185 kW TO 1630 kW. UNIT DESCRIPTION The water coolers of the CWW 702-V÷5602-V series are intended to satisfy the needs of the services sector or industrial systems requiring high power, thus making it convenient to split the workload over several compressors. Equipped with latest generation screw compressors, tube-bundle exchangers and connections for condensation with tower water or well water or with a dry-cooler, they have a series of accessories which are factory-assembled of supplied separately such as: heat recuperator in series or in parallel, soft start and, if necessary, a device for operating a heat pump. Designed and produced to optimize the layout of each component so as to make any necessary maintenance operations more convenient, these units have an essential and compact structure intended for indoor installation. This extremely functional and versatile series includes 20 models with cooling capacities ranging from 185 to 1630 kW. VERSIONS CWW Standard unit 90 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors with built-in oil separator, crankcase heater, oil sight glass, thermal protection andintercepting valves. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. Each refrigerant circuit is supplied with an indipendent condenser. Water connections for well water or closed circuit. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module RZ Compressors stepless control BT Low water temperature device HR Desuperheater HRT Total heat recovery RF Cooling circuit shut off valves FE Evaporator heater SS Soft start DP Device for heat pump operation CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface PV3 3-ways pressostatic valve AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R407C CWW 702-V÷5602-V Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V kW kW kW kW n° 185 47 184 49 2 226 58 225 60 2 246 62 245 64 2 291 72 290 75 2 319 78 318 81 2 370 90 369 93 2 427 103 425 107 2 470 116 468 120 2 526 125 524 130 2 605 140 602 145 2 n° n° l/s kPa DN l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) Kg Kg 2 2 2 2 2 8.84 52 100 11.08 46 2” 10.8 62 100 13.57 48 2” 11.75 43 125 14.72 43 2”½ 13.9 53 125 17.34 43 2”½ 136 308 86 63 1150 1230 160 357 86 63 1310 1390 174 366 86 63 1285 1420 180 393 86 63 1410 1550 CWW 702-V÷5602-V Cooling Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) STD (3) Transport weight Operating weight Screw 2 6 15.24 17.68 30 39 125 125 18.97 21.98 55 58 2”½ 2”½ 400 / 3 / 50 192 248 469 475 87 87 64 64 1575 1845 1720 1980 2 2 2 2 20.4 44 150 25.32 55 2”½ 22.46 53 150 28 39 DN80 25.13 53 150 31.1 50 DN80 28.91 57 200 35.59 44 DN80 280 491 87 64 2010 2200 314 662 89 66 2060 2250 336 663 89 66 2295 2480 410 753 89 66 2460 2760 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V kW kW kW kW n° 633 150 630 156 2 754 176 751 182 2 843 195 840 202 2 897 207 894 213 2 931 215 928 224 2 1026 236 1022 244 2 1096 252 1092 260 2 1332 316 1327 327 2 1508 347 1502 357 2 1630 373 1624 384 2 n° n° l/s kPa DN l/s kPa ”G V/Ph/Hz A A dB(A) dB(A) Kg Kg 2 2 2 2 2 2 2 2 2 2 30.24 60 200 37.41 51 DN80 36.02 49 200 44.43 54 DN80 40.28 43 200 49.59 58 DN80 42.86 45 200 52.75 40 DN100 52.36 51 200 64.4 42 DN100 63.64 53 200 78.74 54 DN100 72.05 59 200 88.63 30 DN125 77.88 56 200 95.7 35 DN125 392 514 89 66 2515 2820 450 579 90 67 2845 3150 490 619 91 68 2855 3200 552 693 91 68 3220 3560 668 929 92 68 4050 4480 800 995 93 69 4210 4790 936 1524 94 70 4810 5430 1002 1560 94 70 4980 5660 Screw 6 44.48 49.02 46 60 200 200 54.75 60.3 41 41 DN100 DN100 400 / 3 / 50 540 600 723 843 92 92 69 69 3240 3830 3580 4150 DIMENSIONS CWW L P H 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V STD STD STD mm mm mm 3300 780 2000 DIMENSIONAL 3300 780 2000 3300 780 2000 3300 780 2000 3300 780 2000 3300 780 2000 3300 780 2000 3100 1420 2150 3100 1420 2150 3100 1420 2150 3100 1420 2150 3100 1420 2150 3100 1420 2150 3300 1450 2150 3800 1450 2150 3800 1550 2200 3800 1550 2200 3800 1650 2200 3 4600 1650 2200 NOTES CLEREANCE AREA CWW 702-V÷ 1602-V A mm B mm C (*) mm D mm 3300 1450 2150 CWW 702-V÷5602-V Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) STD (3) Transport weight Operating weight (1) 500 500 800 500 CWW 1802-V ÷ 5602-V A mm 500 B mm 500 C (*) mm 800 D mm 500 (2) (3) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 91 3 CWW/Y 1302-B÷9003-B WATER COOLED LIQUID CHILLERS WITH SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 267 kW TO 2473 kW. UNIT DESCRIPTION The water coolers of the CWW/Y 1302-B÷9003-B series, with R134a refrigerant, are intended to satisfy the needs of the services sector or industrial systems requiring high power, thus making it convenient to split the workload over several compressors. Equipped with latest generation screw compressors, tube-bundle exchangers and connections for condensation with tower water or well water or with a dry-cooler, they have a series of accessories which are factory-assembled of supplied separately such as: heat recuperator in series or in parallel, soft start and, if necessary, a device for operating a heat pump. Designed and produced to optimize the layout of each component so as to make any necessary maintenance operations more convenient, these units have an essential and compact structure intended for indoor installation. VERSIONS CWW/Y Cooling only FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw semihermetic, with oil separator, cranckcase heater, oil sight glass, thermal protection and shut off valve and stepless capacity steps. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. Each refrigerant circuit is supplied with an indipendent condenser. Water connections for well water or closed circuit. • Shell and tube type evaporator, with two or three indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module RZ Compressors stepless control BT Low water temperature device HR Desuperheater HRT Total heat recovery RF Cooling circuit shut off valves FE Evaporator heater SS Soft start DP Device for heat pump operation Web Monitoring enables remote management of the system WM through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface PV3 3-ways pressostatic valve AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 92 TECHNICAL DATA R134a CWW/Y 1302-B÷9003-B Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg CWW/Y 1302-B÷9003-B Cooling Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) STD (3) Transport weight Operating weight 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 267 57 266 59 2 323 69 322 72 2 374 80 372 83 2 426 90 424 94 2 577 123 574 128 2 660 136 657 142 2 750 150 746 156 2 892 182 889 189 2 2 2 2 2 12.76 51 100 15.48 43 65 15.43 43 125 18.71 49 65 17.87 55 125 21.67 51 65 20.35 60 125 24.67 47 65 178 247 88 69 2124 2240 214 265 88 69 2183 2350 238 333 89 70 2309 2480 270 349 89 70 2340 2510 488 99 486 103 2 Screw 2 6 23.32 48 125 28 36 80 400 / 3 / 50 292 448 88 69 2973 3160 2 2 2 2 27.57 61 150 33.43 52 80 31.53 67 150 38 48 80 35.83 66 150 42.99 45 80 42.62 47 200 51.32 57 80 354 479 89 70 3121 3440 398 501 89 70 3174 3490 438 566 91 72 4274 4580 456 575 92 73 4613 5050 4202-B 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B kW kW kW kW n° 1049 210 1045 219 2 1159 234 1155 244 2 1286 256 1281 269 2 1438 287 1432 299 2 1789 357 1780 374 3 1981 395 1972 415 3 2204 443 2195 463 3 2473 500 2456 528 3 n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg 2 2 2 3 3 3 3 50.12 62 200 60.17 49 100 55.37 51 200 66.55 66 100 2 6 61.44 59 200 73.67 77 100 1612 323 1604 339 2 Screw 2 68.7 65 200 82.42 66 100 85.47 77 250 102.53 66 100 94.65 74 250 113.52 78 100 105.3 65 250 126.47 73 100 118.15 119 250 142.04 63 125 536 615 93 74 4645 5100 552 738 98 78 4650 5220 660 774 99 79 5360 5940 734 952 103 83 5440 6100 77.02 81 200 92.45 63 125 400 / 3 / 50 804 1067 107 85 6000 6690 828 931 103 80 7050 7800 990 988 105 82 8450 9350 1101 1187 106 83 8600 9550 1206 1337 109 87 9250 10270 9 DIMENSIONS CWW/Y L P H 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B STD STD STD mm mm mm 3550 800 2000 DIMENSIONAL 3550 800 2000 3300 1400 2150 3300 1400 2150 3300 1400 2150 3500 1450 2150 3500 1450 2150 3600 1650 2150 3600 1650 2150 3600 1650 2150 4800 1800 2150 4800 1800 2150 CLEREANCE AREA CWW/Y 1302-B÷ 1502-B A mm 500 B mm 500 C (*) mm 800 D mm 500 CWW/Y 1702-B ÷ 9003-B A mm 500 B mm 500 C (*) mm 800 D mm 500 5200 1800 2150 5200 1800 2150 5200 2200 2150 5200 2200 2150 5500 2200 2150 CWW/Y 1302-B÷9003-B Cooling Cooling capacity (1) Absorbed power (1) Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (2) STD (3) Transport weight Operating weight 3 5500 2200 2150 NOTES (1) (2) (3) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 93 3 CWW/IY/WP 1352÷4402 WATER COOLED HEAT PUMPS WITH INVERTER SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 319 kW TO 1171 kW. UNIT DESCRIPTION The watercooled heat pump units of the line CWW/IY/WP 1352÷4402 IDROINVERTER, with refrigerant R134a, are designed to fulfill with the requirements of big sizes installations, such as commercial and industrial plants. The units are provided with screw compressors with the new technology of INVERTER, shell&tube exchangers, the optimisation of the water and cooling circuits, the INVERTER screw compressors, allow the units to reach a very high efficiency and reduced power consumption, if combined with a proper sizing of the end-user plant. VERSIONS CWW/IY/WP Standard unit 94 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw INVERTER compressors, with built-in oil separator, suction filter,cranckcase heater, sight glass, thermal protection, hot gas shut off valves. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. Each refrigerant circuit is supplied with an indipendent condenser. Water connections for well water or closed circuit. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. Factory fitted accessories: IM Protection module BT Low water temperature device HR Desuperheater HRT Total heat recovery RF Cooling circuit shut off valves FE Evaporator heater SS Soft start Web Monitoring enables remote management of the system WM through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. CP Potential free contacts Loose accessories: CR Remote display IS RS 485 serial interface PV3 3-ways pressostatic valve AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch TECHNICAL DATA R134a CWW/IY/WP 1352÷4402 Cooling (EN14511 value) Heating Heating (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound power Sound pressure Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Heating capacity (2) Absorbed power (2) COP Heating capacity (2) Absorbed power (2) COP Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current STD (3) STD (4) Transport weight Operating weight kW kW kW kW kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg 1402 1602 319 65 4.91 318 67 4.71 386 82 4.71 351 81 4.34 2 375 76 4.93 374 79 4.71 454 96 4.73 408 97 4.22 2 433 88 4.92 431 92 4.67 525 112 4.69 478 112 4.29 2 2 2 2 15.24 33 125 18.35 49 125 17.92 40 150 21.55 58 150 20.69 47 150 24.89 68 150 201 87 94 69 2550 2810 231 95 95 70 2940 3470 256 107 95 70 3010 3510 1802 1952 2302 2702 3302 4402 490 576 686 100 117 137 4.9 4.92 5.01 489 574 684 104 122 143 4.71 4.71 4.78 588 697 824 126 147 173 4.67 4.74 4.76 535 634 750 124 146 172 4.31 4.34 4.36 2 2 2 Screw ON/OFF + Screw INVERTER 2 2 2 Stepless 23.41 27.52 32.78 35 43 44 150 200 200 28.19 33.11 39.32 51 61 63 150 200 200 400 / 3 / 50 284 330 390 109 140 153 95 95 95 70 70 70 3400 4090 4500 3860 4800 5250 848 173 4.9 845 180 4.69 1033 218 4.74 935 220 4.25 2 1007 205 4.91 1003 215 4.66 1240 260 4.77 1121 268 4.19 2 1171 237 4.94 1167 248 4.71 1439 298 4.83 1293 305 4.24 2 2 2 2 40.52 45 200 48.78 66 200 48.11 56 200 57.91 81 200 55.95 51 200 67.27 73 200 485 201 97 72 5060 5810 572 243 99 73 5650 6620 649 293 100 75 6300 7450 DIMENSIONS CWW/IY/WP L P H STD STD STD mm mm mm 1352 1402 1602 1802 1952 2302 2702 3302 4402 4000 1200 2000 4300 1400 2000 4300 1400 2000 4300 1400 2000 4300 1500 2000 4300 1600 2000 4300 2200 2000 4600 2200 2000 4600 2200 2000 DIMENSIONAL CWW/IY/WP 1352÷4402 mm mm mm mm 3 NOTES CLEREANCE AREA A B C D (*) CWW/IY/WP 1352÷4402 Cooling 1352 500 500 500 800 (1) (2) (3) (4) (*) Chilled water from 12 to 7°C, water temperature at the condenser from 30°C to 35°C. Hot water from 40° to 45°C. Well water from 15 to 10°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 95 3 CWW/TTY 1801-1÷12806-1 WATERCOOLED LIQUID CHILLERS WITH TURBOCOR COMPRESSORS (MAGNETIC LEVITATION CENTRIFUGES) AND FLOODED SHELL AND TUBE EXCHANGERS FOR FUNCTIONING WITH COOLING TOWER. FROM 333 kW TO 3696 kW. UNIT DESCRIPTION The innovative CWW/TTY 1801-1 ÷ 12806-1 TURBOLINE units, which work with an evaporative tower, are designed to provide an effective solution for highly selective system needs. Efficiency with partial loads, low breakaway starting current, low levels of operational noise, reduced weight and the specific design and handling every manufacturing aspect, make the TURBOLINE series the top of the line unit of CLINT’s design and technical development. Using TURBOCOR dynamic partialization oil-free magnetic levitation compressors, managed by the TURBOSOFT self-adaptive electronic control and flooded shell and tube evaporators, provide high energy performance, with unbeatable IPLV values, eliminating accumulation tanks and low noise levels during operation. Compared to traditional screw compressor units, TURBOLINE units have low operational costs during their entire use, with a savings that can even reach 50%. Besides, the units are equipped with the WEB MONITORING system, for remotely managing and monitoring the units by means of GPRS/GSM/TCP-IP communication protocol. The users enabled to use this service can, through dedicated Web page, access Monitoring, Management and Statistics activities. VERSIONS CWW/TTY Standard unit for cooling tower 96 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in inverter, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. • Flooded shell and tube type evaporator, with casing with high efficiency tube nest designed for R134a. • R134a refrigerant. • Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors, interface relay and terminals for external connections. • TURBOSOFT control and regulation system is fitted with RS 485 serial interface and Web monitoring device for remote monitoring via GSM/GPRS/TCP-IP network. Factory fitted accessories: IM Protection module HR Desuperheater HRT Total heat recovery FE Evaporator heater CP Potential free contacts Loose accessories: CR Remote display FL Flow switch TECHNICAL DATA R134a CWW/TTY 1801-1÷12806-1 Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound levels Weights 1801-1 2301-1 2701-1 3702-1 4102-1 4502-1 5002-1 5302-1 5503-1 333 62 5.37 331 65 5.06 1 396 72 5.5 394 76 5.17 1 523 94 5.56 520 99 5.24 1 682 123 5.54 678 130 5.22 2 999 177 5.64 993 187 5.31 2 1166 214 5.45 1160 224 5.18 2 1265 216 5.86 1260 228 5.53 2 1344 231 5.82 1335 246 5.42 3 1 1 1 1 1 1 1 1 15.91 69 150 18.87 50 125 18.92 72 150 22.36 53 125 24.99 73 150 29.48 53 125 32.58 73 150 38.46 58 125 47.73 85 200 56.19 53 150 55.71 73 200 65.93 49 200 60.44 65 200 70.76 68 200 64.21 106 200 75.25 66 200 135 10 85 66 2690 2840 135 10 85 66 2700 2880 170 16 85 66 2720 2920 340 116 87 67 3200 3440 840 148 5.68 835 156 5.34 2 Turbocor 1 Stepless 40.13 85 200 47.2 53 150 400 / 3 / 50 340 136 87 67 3500 3800 340 160 88 68 3510 3840 340 189 88 68 4020 4480 340 191 90 70 4130 4600 510 266 90 70 5260 5840 kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg CWW/TTY 1801-1÷12806-1 Cooling Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound levels Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Sound capacity (2) Sound pressure (3) Transport weight Operating weight 6103-1 6803-1 7504-1 8404-1 9505-1 10605-1 11706-1 12806-1 1546 268 5.77 1537 286 5.37 3 1792 316 5.67 1783 335 5.32 3 2050 355 5.77 2038 379 5.37 4 2352 429 5.48 2339 454 5.15 4 2688 470 5.72 2674 499 5.36 5 3024 539 5.61 3008 573 5.25 5 3360 596 5.64 3343 631 5.29 6 3696 647 5.71 3676 687 5.35 6 1 1 1 1 1 1 1 1 73.86 98 200 86.67 77 200 85.62 78 250 100.72 82 200 97.94 99 250 114.91 85 200 144.48 95 300 170.23 85 250 160.53 91 300 189 81 300 176.59 98 300 207.5 82 300 510 306 90 70 5820 6560 510 358 91 71 5940 6700 680 448 92 72 6250 7040 850 716 94 73 10290 11960 1020 821 95 74 11900 14080 1020 891 95 75 11940 14120 kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg Turbocor Stepless 112.37 128.48 94 87 300 250 132.87 150.88 71 83 250 250 400 / 3 / 50 680 850 538 624 93 94 73 73 8020 8170 9120 9560 DIMENSIONS CWW/TTY L H P STD STD STD mm mm mm 1801-1 2301-1 2701-1 3702-1 4102-1 4502-1 5002-1 5302-1 5503-1 6103-1 6803-1 7504-1 8404-1 3220 2170 980 3220 2170 980 3180 2170 1000 3260 2400 1120 3340 2400 1160 3340 2400 1160 3360 2450 1260 3360 2450 1260 4300 2450 1250 4400 2520 1420 4400 2520 1420 4370 2520 1470 4500 2660 1630 DIMENSIONAL CLEREANCE AREA CWW/TTY 1801-1÷12806-1 A mm 500 B mm 500 C mm 500 D (*) mm 800 9505-1 10605-1 11706-1 12806-1 5620 2820 1510 5750 2800 1630 6040 3000 1800 CWW/TTY 1801-1÷12806-1 Cooling Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Sound capacity (2) Sound pressure (3) Transport weight Operating weight 3 6040 3000 1800 NOTES (1) (2) (3) (*) Chilled water from 12° to 7°C. Condensing water from 30° to 35°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 97 3 CWW/TTY/DR 1401-1÷6104-1 WATERCOOLED LIQUID CHILLERS WITH TURBOCOR COMPRESSORS (MAGNETIC LEVITATION CENTRIFUGES) AND FLOODED SHELL AND TUBE EXCHANGERS FOR FUNCTIONING WITH DRY-COOLER. FROM 280 kW TO 1546 kW. UNIT DESCRIPTION The innovative CWW/TTY/DR 1401-1 ÷ 6104-1 TURBOLINE units, which work with an dry-cooler, are designed to provide an effective solution for highly selective system needs. Efficiency with partial loads, low breakaway starting current, low levels of operational noise, reduced weight and the specific design and handling every manufacturing aspect, make the TURBOLINE series the top of the line unit of CLINT’s design and technical development. Using TURBOCOR dynamic partialization oil-free magnetic levitation compressors, managed by the TURBOSOFT self-adaptive electronic control and flooded shell and tube evaporators, provide high energy performance, with unbeatable IPLV values, eliminating accumulation tanks and low noise levels during operation. Compared to traditional screw compressor units, TURBOLINE units have low operational costs during their entire use, with a savings that can even reach 50%. Besides, the units are equipped with the WEB MONITORING system, for remotely managing and monitoring the units by means of GPRS/ GSM/TCP-IP communication protocol. The users enabled to use this service can, through dedicated Web page, access Monitoring, Management and Statistics activities. VERSIONS CWW/TTY/DR Standard unit for dry-cooler 98 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in inverter, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. • Flooded shell and tube type evaporator, with casing with high efficiency tube nest designed for R134a. • R134a refrigerant. • Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors, interface relay and terminals for external connections. • TURBOSOFT control and regulation system is fitted with RS 485 serial interface and Web monitoring device for remote monitoring via GSM/GPRS/TCP-IP network. Factory fitted accessories: IM Protection module HR Desuperheater HRT Total heat recovery FE Evaporator heater CP Potential free contacts Loose accessories: CR Remote display FL Flow switch TECHNICAL DATA R134a CWW/TTY/DR 1401-1÷6104-1 Cooling (EN14511 value) Compressors Evaporator Condenser Electrical characteristics Sound levels Weights Cooling capacity (1) Absorbed power (1) EER Cooling capacity (1) Absorbed power (1) EER Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Water flow Pressure drops Water connections Power supply Max. running current Inrush current Sound capacity (2) Sound pressure (3) Transport weight Operating weight kW kW kW kW n° n° n° l/s kPa DN l/s kPa DN V/Ph/Hz A A dB(A) dB(A) Kg Kg 1701-1 2302-1 3202-1 4202-1 4303-1 4903-1 5504-1 6104-1 280 66 4.21 279 68 4.09 1 336 83 4.07 335 86 3.91 1 448 107 4.18 446 111 4.03 2 594 142 4.19 591 147 4.02 2 952 230 4.14 950 234 4.07 3 1142 260 4.39 1135 272 4.17 3 1344 311 4.32 1337 324 4.12 4 1546 350 4.41 1538 366 4.21 4 1 1 1 1 1 1 1 1 13.38 40 150 16.55 39 125 16.05 43 150 20 42 125 21.4 51 150 26.52 45 125 28.38 56 150 35.15 48 125 45.48 25 200 56.48 20 150 54.56 88 200 66.99 63 200 64.21 76 200 79.08 65 200 73.86 77 250 90.6 69 200 135 10 85 66 2690 2840 135 10 85 66 2690 2880 270 93 87 68 2910 3080 270 122 87 68 2920 3120 762 173 4.39 759 179 4.24 2 Turbocor 1 Stepless 36.41 52 200 44.69 45 150 400 / 3 / 50 270 148 87 67 3470 3760 405 252 89 69 4600 5080 405 286 89 69 5210 5760 540 379 91 71 5480 6040 540 427 91 71 6130 6920 DIMENSIONS CWW/TTY/DR L H P STD STD STD mm mm mm 1401-1 1701-1 2302-1 3202-1 4202-1 4303-1 4903-1 5504-1 6104-1 3220 2170 980 3220 2170 980 3200 2170 1000 3220 2170 1000 3340 2400 1150 4260 2400 1160 4270 2450 1250 4270 2450 1410 4370 2520 1470 DIMENSIONAL CWW/TTY/DR 1401-1÷6104-1 mm mm mm mm 3 NOTES CLEREANCE AREA A B C D (*) CWW/TTY/DR 1401-1÷6104-1 Cooling 1401-1 500 500 500 800 (1) (2) (3) (*) Chilled water from 12° to 7°C. Condensing water (with ethilenic glycol at 35%) from 40° to 45°C. Sound power level according to Standard ISO 3744 and Eurovent 8/1. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Electrical board side. 99 3 CWW/CCY 4031÷11682 WATER CHILLERS WATER / WATER WITH CENTRIFUGAL COMPRESSOR AND FLOODED SHELL AND TUBE EXCHANGERS. FROM 1600 kW TO 9000 kW. UNIT DESCRIPTION The CWW / CCY 4031 ÷ 11682 CENTRITEK units, with R134a refrigerant gas and innovative technology, are the technologic and innovative heart of the most selective air conditioning and refrigeration systems designed by CLINT. These units are designed especially for large size systems, intensively used throughout the year. The units, equipped with INVERTER technology, combined with the use of last generation centrifugal compressors, reach outstanding EER and ESEER energy coefficients: respectively up to 6,4 at full load and up to 10 at partial load. The extremely high reliability of the series is achieved through the careful control of power, even at partial loads, which minimizes the number of stops and starts and extends the useful life of the compressor. The solidity of the mechanical parts and the wide range of solutions in terms of accessories and system arrangements make the unit sturdy, but at the same time flexible, suitable for any type of application. In addition, the units are equipped with a WEB MONITORING system, for the monitoring and remote management of the units through the communication protocol GPRS / GSM / TCPIP. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSIONS CWW/CCY Standard unit 100 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Single stage gear driven semi – hermetic centrifugal compressor with high strength aluminum alloy impeller. The compressor is complete with gear drive and loading and unloading mechanism consisting of inlet guide vanes. The electric motor is an accessible hermetically sealed liquid refrigerant cooled squirrel cage two pole induction motor. • Shell and tube type condenser, with easily removable cast iron heads to enable acess for maintenance operations. • Flooded shell and tube type evaporator, with casing with high efficiency tube nest designed for R134a. • R134a refrigerant. • Lubrication system with submersible oil pump, to prevent any sudden changes in tension. • Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors, interface relay and terminals for external connections. • CENTRISOFT control and regulation system is fitted with RS 485 serial interface and Web monitoring device for remote monitoring via GSM/GPRS/TCP-IP network. Factory fitted accessories: MW Marine water boxes PW High water pressure heat exchangers CK Cupro – Nickel or Stainless Steel Tubes Loose accessories: FE Evaporator heater SS Soft start TECHNICAL DATA R134a CWW/CCY 4031÷11682 kW Kg Kg mm mm mm 4631 5241 5841 8062 9262 10482 11682 1600 ÷ 2150 1950 ÷ 3000 2650 ÷ 3000 3000 ÷ 4400 1750 ÷ 2300 2100 ÷ 4300 4000 ÷ 6000 5600 ÷ 9000 9350 14550 15900 15900 20200 20200 26850 26850 10100 17100 19000 19000 23400 23400 31300 31300 4270 4450 4450 4450 5560 5560 5710 5710 2670 2700 2700 2700 2540 2540 2970 2970 2030 2490 2650 2650 2350 2350 3130 2870 CONTROL PANEL The unit is provided with CENTRISOFT control system, with touch-screen to illustrate the functioning status of the machine and the operational parameters (set points). Latest generation software with calculation algorithms optimise operational conditions of the compressor(s), of the expansion and inlet valves, keeps the unit stable in highly effi cient working conditions. Cooling capacity CENTRITEK is provided with protection against damages due to sudden stop; in fact, the units are provided with spring-loaded piston that, in case of no current, causes forced lubrication of the compressor. EFFICIENCY AT PARTIAL LOAD SINGLE COMPRESSOR The CENTRITEK units enable up to 10% distribution control of the full charge for single compressor coolers and up to 5% for double compressor units. This entails a signifi cant energy saving and elongation of the useful life of the compressor, which stress is reduced also by using a mobile delivery diffuser, that increases its stability limiting vibrations. SINGLE COMPRESSOR 7,6 DOUBLE COMPRESSOR DOUBLE COMPRESSOR 10 0 2000 4000 6000 8000 10000 kW CWW/CCY 4031÷11682 Cooling capacity (1) Transport weight Weights Operating weight Max length DIMENSIONS Max width Max height 4031 0 2 4 6 8 3 10 ESEER CONNECTION DIAGRAM LEGENDA 1 power supply. 2 Start-up panel 3 Compressor power supply 4 Controller 5 Centrifugal compressor CENTRITEK, extremely compact unit, designed for easy installation and connection to the system; maintenance is made easier by the attentive disposition of the components and by the possibility, in case of double compressor unit, to insulate the circuit of interest, without jeopardising functioning continuity of the unit. NOTES (1) Chilled water from 12° to 7°C. Condensing water from 30° to 35°C. 101 3 RCW 6121÷9282 DRY COOLERS WITH AXIAL FANS. UNIT DESCRIPTION The DRY COOLERS with axial fans of the RCW series are designed to be combined with water cooled liquid chillers (CWW). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCW CWW/K 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P RCW 6121 8111 6132 6134 8121 8122 6141 8131 8132 6151 CWW/K 726-P RCW 8141 8141 8152 8152 8241 8241 8242 8243 8243 8252 Standard unit CWW/K RCW FEATURES • Frame in pre-painted galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 102 826-P 906-P 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 8261 9261 9261 9271 9282 9282 2x8262 CWW 802 RCW 8141 8141 8151 8231 8232 8232 8241 8242 8251 8251 CWW 2204 2404 3004 3204 RCW 8261 8262 8262 9261 CWW 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V RCW 8132 8141 8141 8152 8231 8241 8242 8243 8251 8261 CWW 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V RCW 8261 9261 9262 9271 9281 9282 9282 2x8262 2x9261 2x9262 CWW/Y RCW ACCESSORIES 786-P CWW/Y RCW 902 1002 1102 1202 1502 1602 1604 1804 2004 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B 8151 8231 8241 8242 8243 8252 8261 9261 9271 9282 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B 9282 2x8262 2x9261 2x9262 2x9271 2x9281 3x8262 3x9261 CWW/TTY/DR 1401-1 1701-1 2302-1 3202-1 4202-1 4303-1 4903-1 5504-1 6104-1 RCW 8261 8262 9281 2x8261 2x8262 2x9282 3x8262 3x9281 3x9282 TECHNICAL DATA H2O RCW 6121÷9282 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCW 6121÷9282 Air flow Connections Electrical characteristics Condenser Transport weight 4.67 42 42 7.32 42 42 7.01 54 54 6.56 54 54 12.31 54 54 15.44 54 54 1.32 2.6 12 49 145 1.98 3.9 3 51 191 1.98 3.9 3 51 205 1.98 3.9 3 51 245 4.95 9.3 3 57 239 6.6 12.4 4 58 337 17.86 80 80 5.18 10.83 42 70 42 70 400/3/50 8.25 2 4 15.5 4 8 5 1 2 59 49 52 516 182 308 10.37 70 70 16.25 80 80 15.55 102 102 20.73 102 102 27.08 70 70 25.92 70 70 4 8 2 52 326 6 12 3 53 470 6 12 3 53 497 8 16 4 54 646 10 20 5 55 684 10 20 5 55 724 8231 8232 8241 8242 8243 8251 8252 8261 8262 9261 9262 9271 9281 9282 IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 31.96 102 102 30.45 2x102 2x102 44.8 102 102 42.62 102 102 40.6 2x102 2x102 53.28 2x102 2x102 12 24 6 56 860 12 24 6 56 910 16 32 8 57 994 16 32 8 57 1204 16 32 8 57 1274 20 40 10 58 1548 50.75 63.93 3x102 3x102 3x102 3x102 400/3/50 20 24 40 48 10 12 58 58 1638 1892 65.33 3x102 3x102 68.5 4x80 4x80 65.33 4x80 4x80 76.22 6x102 6x102 91.33 4x102 4x102 87.11 6x102 6x102 24 48 12 59 3390 24 48 12 59 3060 24 48 12 59 3390 28 56 14 59 3890 32 64 16 60 3960 32 64 16 60 4380 DIMENSIONS RCW L P H 6121 6131 6132 6133 6134 6141 6151 8111 8121 8122 8131 8132 8141 8151 8152 8231 8232 8241 8242 8243 8251 8252 8261 8262 9261 9262 9271 9281 9282 STD STD STD mm mm mm RCW 6121÷9282 Connections 6121 6131 6132 6133 6134 6141 6151 8111 8121 8122 8131 8132 8141 8151 8152 m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 2425 3525 3525 3525 3525 4625 5725 1803 3278 3278 4753 4753 6228 7703 7703 4783 4783 6258 6258 6258 7733 7733 9208 9208 6920 6920 8020 9120 9120 630 630 630 630 630 630 630 795 795 795 795 795 795 795 795 878 878 878 878 878 878 878 878 878 2350 2350 2350 2350 2350 1098 1098 1098 1098 1098 1098 1098 1272 1272 1272 1272 1272 1272 1272 1272 2322 2322 2322 2322 2322 2322 2322 2322 2322 2450 2450 2450 2450 2450 DIMENSIONAL NOTES (1) 6121 ÷ 8262 9261 ÷ 9282 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at Ambient air temperature 35°C, Inlet/Outlet water temperature 50°C/45°C (with ethilenic glycol at 35%). 103 3 RCW/SL 6122÷9281 SILENCED DRY COOLERS WITH AXIAL FANS. UNIT DESCRIPTION The DRY COOLERS with axial fans of the RCW series are designed to be combined with water cooled liquid chillers (CWW). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCW/SL CWW/K 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P RCW/SL 6122 6131 6141 8121 8131 6151 6152 8132 8142 8142 CWW/K 726-P RCW/SL 8152 8152 8231 8231 8242 8243 8251 8252 8252 8262 Silencied unit FEATURES • Frame in pre-painted galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 104 786-P 826-P 906-P 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P CWW/K 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P RCW/SL 9261 9271 9271 9281 2x8252 2x8261 2x9262 CWW 802 RCW/SL 8151 8152 8231 8241 8242 8242 8243 8252 8261 8261 CWW 2204 2404 3004 3204 RCW/SL 9261 9262 9271 9272 CWW 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V RCW/SL 8142 8151 8152 8231 8241 8243 8251 8252 8261 9261 CWW 902 1002 1102 1202 1502 1602 1604 1804 2004 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V RCW/SL 9261 9271 9272 9281 2x8252 2x8252 2x8261 2x9262 2x9271 2x9272 CWW/Y 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B RCW/SL 8152 8241 8242 8251 8252 8262 9261 9271 9281 2x8252 CWW/Y 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B RCW/SL 2x8261 2x9262 2x9271 2x9272 2x9281 3x9261 3x9262 3x9271 CWW/TTY/DR 1401-1 1701-1 2302-1 3202-1 4202-1 4303-1 4903-1 5504-1 6104-1 RCW/SL 9261 9262 2x8252 2x9261 2x9271 3x9262 3x9271 4x9262 4x9272 TECHNICAL DATA H2O RCW/SL 6122÷9281 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCW/SL 6122÷9281 Air flow Connections Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 6122 6131 6132 6141 6151 6152 8121 8131 8132 8141 8142 8151 8152 4.67 42 42 6.01 54 54 5.66 54 54 8.01 54 54 9.04 70 70 10.9 80 80 13.1 70 70 11.78 70 70 16.49 80 80 15.71 102 102 20.61 102 102 19.64 102 102 1.32 2.6 2 49 145 1.2 2.1 3 44 145 1.2 2.1 3 44 145 1.6 2.8 4 45 145 2 3.5 5 46 388 3.3 6.5 5 52 448 8.24 54 54 400/3/50 2.5 4.6 2 45 308 3.75 6.9 3 47 388 3.75 6.9 3 47 497 5 9.2 4 48 611 5 9.2 4 48 646 6.25 11.5 5 49 684 6.25 11.5 5 49 724 8231 8241 8242 8243 8251 8252 8261 8262 9261 9262 9271 9272 9281 21.95 2x102 2x102 34.9 102 102 32.26 102 102 29.27 102 102 40.32 2x102 2x102 36.58 2x102 2x102 52.33 2x102 2x102 49.08 2x102 2x102 61.06 2x102 2x102 57.26 4x80 4x80 65.44 4x80 4x80 7.5 13.8 6 50 910 10 18.4 8 51 994 10 18.4 8 51 1204 10 18.4 8 51 1274 12.5 23 10 51 1548 12.5 23 10 51 1638 48.39 43.9 3x102 3x102 3x102 3x102 400/3/50 15 15 27.6 27.6 12 12 52 52 1892 2200 15 27.6 12 52 3060 15 27.6 12 52 3390 17.5 32.2 14 53 3510 17.5 32.2 14 53 3890 20 36.8 16 53 4380 DIMENSIONS RCW/SL L P H 6122 6131 6132 6141 6151 6152 8121 8131 8132 8141 8142 8151 8152 8231 8241 8242 8243 8251 8252 8261 8262 9261 9262 9271 9272 9281 STD STD STD mm mm mm RCW/SL 6122÷9281 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 2425 3525 3525 4625 5725 5725 3278 4753 4753 6228 6228 7703 7703 4783 6258 6258 6258 7733 7733 9208 9208 6920 6920 8020 8020 9120 630 630 630 630 630 630 795 795 795 795 795 795 795 878 878 878 878 878 878 878 878 2350 2350 2350 2350 2350 1098 1098 1098 1098 1098 1098 1272 1272 1272 1272 1272 1272 1272 2322 2322 2322 2322 2322 2322 2322 2322 2450 2450 2450 2450 2450 DIMENSIONAL NOTES (1) 6122 ÷ 8262 9261 ÷ 9281 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at Ambient air temperature 35°C, Inlet/Outlet water temperature 50°C/45°C (with ethilenic glycol at 35%). 105 3 RCW/SSL 6132÷9282 SUPER SILENCED DRY COOLERS WITH AXIAL FANS. UNIT DESCRIPTION The DRY COOLERS with axial fans of the RCW series are designed to be combined with water cooled liquid chillers (CWW). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCW/SSL CWW/K RCW/SSL 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 6132 6141 6151 8131 8132 8141 8151 8152 8231 8241 CWW/K RCW/SSL 726-P Super silencied unit CWW/K RCW/SSL • Frame in pre-painted galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 106 826-P 906-P 1048-P 1128-P 1208-P 13010-P 15010-P 16812-P 18012-P 21012-P 24012-P 27012-P 30012-P 33012-P 36012-P 2x8261 2x8262 2x8263 2x9261 2x9282 2x9282 3x8264 CWW 802 RCW/SSL 8241 8242 8251 8253 8261 8262 8263 9261 9271 9282 CWW FEATURES 786-P 8242 8242 8252 8252 8262 8262 8264 9271 9271 9282 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 2404 3004 3204 RCW/SSL 2x8261 2x8262 2x8262 2x8263 CWW 702-V 802-V 902-V 1102-V 1202-V 1502-V 1602-V 1802-V 2002-V 2202-V RCW/SSL 8231 8242 8242 8252 8261 8262 9261 9271 9281 2x8261 CWW 2402-V 3202-V 3302-V 3402-V 3602-V 4002-V 4202-V 4602-V 5002-V 5602-V RCW/SSL 2x8261 2x8263 2x8264 2x9261 2x9271 2x9282 2x9282 3x8264 3x9271 3x9282 CWW/Y 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B RCW/SSL 8251 8253 8262 8264 9271 9282 2x8261 2x8262 2x9261 2x9282 CWW/Y 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B RCW/SSL 2x9282 3x8264 3x9271 3x9282 3x9282 4x9261 4x9271 4x9282 CWW/TTY/DR 1401-1 1701-1 2302-1 3202-1 4202-1 4303-1 4903-1 5504-1 6104-1 RCW/SSL 2x8261 2x8262 2x9271 2x9282 3x9271 4x9271 4x9282 5x9271 5x9282 TECHNICAL DATA H2O RCW/SSL 6132÷9282 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCW/SSL 6132÷9282 Air flow Connections Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 6132 6141 6142 6151 6152 3.83 54 54 5.51 54 54 5.11 54 54 6.88 70 70 6.38 70 70 8131 0.57 1.1 3 35 191 0.76 1.5 4 36 256 0.76 1.5 4 36 273 0.95 1.9 5 37 332 0.95 1.9 5 37 363 8242 8251 8252 8253 8261 8262 19.53 102 102 25.97 102 102 24.4 2x102 2x102 24.4 102 102 31.17 102 102 2.96 9.6 8 40 1204 3.7 12 10 41 1278 3.7 12 10 41 1548 3.7 12 10 41 1548 4.4 14.4 12 42 1562 8132 8141 8151 8152 8231 8241 9.87 80 80 13.11 80 80 12.33 80 80 15.58 102 102 20.78 102 102 1.48 4.8 4 38 611 1.85 6 5 38 562 1.85 6 5 38 684 2.22 7.2 6 39 710 2.96 9.6 8 40 994 8263 8264 9261 9271 9281 9282 29.29 30.56 2x102 3x102 2x102 3x102 400/3/50 4.4 5.64 14.4 12 12 12 42 43 1892 1892 27.35 2x102 2x102 31.5 2x102 2x102 36.75 2x102 2x102 39.66 2x102 2x102 36.77 4x80 4x80 5.64 12 12 43 2200 4.44 14.4 12 42 3060 5.18 16.8 14 42 3510 7.52 16 16 44 3960 7.52 16 16 44 4380 7.8 7.64 70 70 70 70 400/3/50 1.41 1.41 3 3 3 3 38 38 470 497 DIMENSIONS RCW/SSL L P H 6132 6141 6142 6151 6152 8131 8132 8141 8151 8152 8231 8241 8242 8251 8252 8253 8261 8262 8263 8264 9261 9271 9281 9282 STD STD STD mm mm mm 3525 630 1098 4625 630 1098 4625 630 1098 5725 630 1098 DIMENSIONAL 5725 630 1098 4753 795 1272 6228 795 1272 7703 795 1272 7703 795 1272 7703 795 1272 4783 878 2322 6258 878 2322 4783 878 2322 7733 878 2322 7733 878 2322 7733 878 2322 9208 878 2322 9208 878 2322 9208 878 2322 9208 878 2322 6920 2350 2450 8020 2350 2450 9120 2350 2450 RCW/SSL 6132÷9282 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 9120 2350 2450 NOTES (1) 6132 ÷ 8264 9261 ÷ 9282 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at Ambient air temperature 35°C, Inlet/Outlet water temperature 50°C/45°C (with ethilenic glycol at 35%). 107 3 MEA/K 15÷151 WATER COOLED LIQUID CHILLERS AND HEAT PUMPS FOR REMOTE CONDENSING WITH ROTARY/SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 4 kW TO 41 kW. UNIT DESCRIPTION The water coolers and heat pumps for remote condensation of the MEA/K 15÷151, with R410A refrigerant, series are intended to satisfy the needs of domestic or service sector systems which require medium power, space-saving units and quiet operation. In fact, combined with the remote condenser, these units are ideal for indoor installation and, equipped with a self-contained structure, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier. Equipped with Rotary/Scroll compressors and plate-type exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in the version with tank and pump; and a series of accessories supplied separately rounds off the variety of equipment in this product range. This extremely functional and versatile series includes 14 models with cooling capacities ranging from 4 to 41 kW. VERSIONS MEA/K Standard unit MEA/K/SP Standard unit with tank and pump 108 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Rotary/Scroll compressors with internal overheat protection and crankcase heater if needed. • Evaporator in AISI 316 stainless steel brazewelded plates type, complete with water differential pressure switch. • R410A refrigerant. • Electrical pane includes: main switch with door lock device, fuses, compressor and pump remote control switch (51÷151). • Microprocessor control and regulation system. • Water circuit SP versions includes: insulated tank, circulator or pump, safety valve, gauge and plant expansion vessel. Factory fitted accessories: BT Low water temperature device Loose accessories: PS Circulating pump PB Low pressure switch CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A MEA/K 15÷151 Heating Compressors Evaporator Connections Electrical characteristics Version with tank and pump Sound pressure Weights 18 21 25 31 41 51 4 1.4 5.1 1.5 1 5.1 1.8 6.4 1.9 1 6.2 2.1 8.2 2.4 1 7.3 3 9.4 2.7 1 8.5 3.3 10.7 3 1 12.1 3.3 15.5 4.5 1 l/s kPa ”G Ø Ø V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G STD (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg 0.19 15 1” 12 10 0.24 15 1” 12 10 0.3 20 1” 12 10 0.35 18 1” 12 10 0.41 20 1” 12 10 10.1 3.7 13.2 4.2 1 Scroll 0.48 25 1” 12 10 7 37 0.2 50 50 2 1” 36 74 99 75 150 9 43 0.2 45 50 2 1” 36 75 101 76 152 11 62 0.21 75 50 2 1” 36 77 103 78 154 12 63 0.21 70 50 2 1” 36 81 105 82 156 15 79 0.21 70 50 2 1” 37 84 107 85 158 18 86 0.21 60 50 2 1” 39 87 109 88 160 0.58 35 1” 16 12 400 / 3+ N / 50 8 58 0.3 180 50 2 1” 39 86 110 88 161 61 71 81 91 101 131 151 Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Suction Line Liquid Line Power supply Max. running current Inrush current Pump nominal power 14.5 5.2 18.5 5.5 1 17 6 22 6.5 1 20 7.1 25.9 7.7 1 28.8 9.3 36.4 10.1 1 33.9 10.9 43 11.7 1 41.5 13.3 53.2 14.2 1 0.69 28 1” 16 12 0.81 35 1” 16 12 0.96 39 1” 16 12 1.38 45 1” 22 12 1.62 40 1” 22 12 1.98 40 1” 22 16 10 61 0.3 170 50 2 1” 40 89 113 91 162 10 58 0.3 140 50 2 1” 41 91 115 93 165 12 74 0.3 110 50 2 1” 43 93 117 95 167 24.1 7.8 30.4 8.3 1 Scroll 1.15 40 1” 22 12 400 / 3+ N / 50 23 142 0.55 215 150 5 1” 43 183 262 186 415 29 147 0.55 130 150 5 1” 43 189 268 192 421 30 142 0.55 155 150 5 1” 44 195 274 198 427 30 142 0.75 235 150 5 1” 44 206 285 209 438 kW kW kW kW n° kW kW kW kW n° MEA/K 15÷151 Cooling Heating Compressors Evaporator Connections Electrical characteristics Version with tank and pump Sound pressure Weights l/s kPa ”G Ø Ø V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections ”G STD (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg Rotary 230/1/50 DIMENSIONS MEA/K L P H STD SP WP/SP STD STD mm mm mm mm mm 15 18 21 25 31 41 51 61 71 81 91 101 131 151 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 550 550 550 1200 550 1100 1100 550 1200 550 1100 1100 550 1200 550 1100 1100 550 1200 550 1100 1100 550 1200 DIMENSIONAL 15 ÷ 151 3 NOTES CLEREANCE AREA SP 91÷151 MEA/K 15÷151 Cooling 15 Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Water flow Pressure drops Water connections Suction Line Liquid Line Power supply Max. running current Inrush current Pump nominal power (1) MEA/K 15÷151 A mm B mm C mm D (*) mm 500 200 500 800 MEA/K/SP 15÷151 A mm B mm C mm D (*) mm 800 500 800 800 (2) (3) (4) (5) (*) Chilled water from 12 to 7 °C, condensing temperature 50 °C. Heated water from 40 to 45 °C, evaporating temperature 0 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump (ISO 3744). D SIDE: Electrical board side. 109 3 MEA/K 182-P÷604-P WATER COOLED LIQUID CHILLERS AND HEAT PUMPS FOR REMOTE CONDENSING WITH SCROLL COMPRESSORS AND PLATE EXCHANGERS. FROM 51 kW TO 176 kW. UNIT DESCRIPTION MEA/K 182-P÷604-P series water chillers and heat pumps for remote condensation are designed to meet the needs of residential or industrial-type systems requiring high power together with spacesaving and quiet operation. In fact, these units are ideal for indoor installation and, equipped with a monobloc structure, minimise overall dimensions while also facilitating installation and maintenance operations. They can be combined with terminal units and, if necessary, with the innovative CLIMAFRIEND supervision and control system for programming and effectively obtaining optimum comfort levels. Equipped with Scroll compressors and plate-type exchangers they have refrigerant and hydraulic circuits, even in the version with tank, with pump or tank and pump, complete with everything necessary for quick installation operations and for high energy efficiencies. Also, a number of accessories (factory-fitted or supplied separately), such as the desuperheater or the total heat recuperator, enhance and complete the equipment of this range. Extremely functional and versatile, the range includes 10 models with cooling capacities of 51 to 176 kW. VERSIONS MEA/K Standard unit 110 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Evaporator AISI 316 stainless steel braze welded plate type: With one circuit on the refrigerant side and one on the water side in models 182-P ÷ 453-P; with two independent circuits on the refrigerant side and one on the water side in models 524-P÷604-P, complete with water differential pressure switch. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low water temperature device DS Desuperheater RT Total heat recovery Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface SPU Additional module with inertial tank and single circulating pump SPD Additional module with inertial tank and double circulating pump AG Rubber shock absorbers TECHNICAL DATA R410A MEA/K 182-P÷604-P Heating Compressors Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 50.8 15.4 59.5 18 2 57.1 17.3 65.8 20 2 64.3 19 74.3 22.3 2 73.6 21.6 84.7 24.7 2 87.1 25.8 96.5 27.8 2 98.8 29.4 106.6 32.8 3 113.5 32.9 121.8 37.2 3 134.2 38.7 148.2 41.1 3 148.7 43.5 157.1 50.8 4 176 51.5 193.8 56.5 4 1 1 1 1 1 1 2 3.52 42 1”1/4 28 22 1 3 5.42 44 2”1/2 28 22 6.41 51 2”1/2 28 22 7.1 41 2”1/2 2 x 28 2 x 22 8.41 40 2”1/2 2 x 28 2 x 22 49 165 1.1 135 300 12 2” 1/2 57 386 606 390 910 73 189 1.5 120 300 12 2” 1/2 57 581 811 590 1120 88 233 1.5 110 300 12 2” 1/2 59 595 825 605 1135 97 213 1.85 120 300 12 2” 1/2 59 669 899 680 1210 117 262 18.5 100 300 12 2” 1/2 60 708 938 720 1250 kW kW kW kW n° Scroll n° n° l/s Evaporator kPa ”G Suction Line Ø mm Connections Liquid Line Ø mm Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Pump nominal power kW Pump available static press. kPa Version with tank Storage water volume l and pump Expansion vessel l Water connections ”G Sound pressure STD (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Weights Operating weight (4) Kg Operating weight (5) Kg 2.43 47 1”1/4 28 22 2.73 42 1”1/4 28 22 1 2 3.07 41 1”1/4 28 22 38 161 0.75 105 300 12 2” 1/2 55 347 567 350 870 41 163 0.75 110 300 12 2” 1/2 56 357 577 360 880 44 140 0.75 100 300 12 2” 1/2 56 376 596 380 900 4.16 4.72 40 48 2”1/2 2”1/2 28 28 22 22 400 / 3 / 50 59 66 204 162 1.1 1.5 120 130 300 300 12 12 2” 1/2 2” 1/2 58 57 397 562 617 782 405 570 925 1090 2 4 DIMENSIONS MEA/K L L (STD+SPU) L (STD+SPD) P H STD STD STD STD STD mm mm mm mm mm DIMENSIONAL 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 1200 2310 2310 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 2285 3395 3395 680 1520 (1) MEA/K 182-P÷604-P mm mm mm mm 3 NOTES CLEREANCE AREA A B C (*) D MEA/K 182-P÷604-P Cooling 182-P 1907 300 800 300 (2) (3) (4) (5) (*) Chilled water from 12 to 7 °C, condensing temperature 50 °C. Heated water from 40 to 45 °C, evaporating temperature 0 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. C SIDE: Electrical board side. 111 3 MEA/Y 1302-B÷9003-B WATER COOLED LIQUID CHILLERS FOR REMOTE CONDENSING WITH SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 235 kW TO 2170 kW. UNIT DESCRIPTION The water coolers for remote condensation of the MEA/Y 1302÷9003 series, with R134a refrigerant, are intended to satisfy the needs of the services sector or industrial systems which require high power with continual refrigerant delivery, space-saving units and quiet operation. In fact, combined with the remote condenser, these units are ideal for indoor installation and, equipped with a self-supporting structure that sustains the main components, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier. Equipped with latest generation screw compressors and tube-bundle exchangers; they have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency; and a series of accessories, factory-assembled or supplied separately, rounds off the variety of equipment in this product range. VERSIONS MEA/Y Standard unit FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Screw compressors with built-in oil separator, crankcase heater, oil sight glass, thermal protection andintercepting valves. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • Electronic thermostatic valve. • R134a refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors. Factory fitted accessories: IM Protection module RZ Compressors stepless control BT Low water temperature device HR Desuperheater HRT Total heat recovery RF Cooling circuit shut off valves FE Evaporator heater SS Soft start Web Monitoring enables remote management of the system WM through communication protocols, GPRS/GSM/TCP-IP. Authorized users have access to a dashboard display that provides critical system information from which the user can measure, manage and report as necessary. CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 112 TECHNICAL DATA R134a MEA/Y 1302-B÷9003-B Compressors Evaporator Connections Electrical characteristics Sound pressure Weights 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B kW kW n° 235 73 2 279 85 2 325 103 2 375 118 2 526 158 2 599 176 2 672 193 2 778 228 2 n° n° l/s kPa DN Ø mm Ø mm V/Ph/Hz A A dB(A) Kg Kg 2 2 2 2 2 2 2 2 11.23 49 100 2 x 42 2 x 35 13.33 34 125 2 x 42 2 x 35 15.53 39 125 2 x 54 2 x 35 17.92 41 125 2 x 54 2 x 35 25.13 50 150 2 x 64 2 x 42 28.62 48 150 2 x 64 2 x 42 32.11 55 150 2 x 76 2 x 42 37.17 51 150 2 x 76 2 x 54 156.8 381.4 69 1480 1570 193 469.5 69 1820 1960 213.2 386.6 70 1840 1990 243.2 472.6 70 1860 2010 424 133 2 Screw 2 2 20.26 34 125 2 x 54 2 x 35 400 / 3 / 50 279.6 634.8 69 1900 2040 343.8 817.9 70 2420 2680 381.2 551.6 70 2540 2820 430.8 576.4 72 2590 2850 495.4 621.7 73 3190 3460 MEA/Y 1302-B÷9003-B Cooling Compressors Evaporator Connections Electrical characteristics Sound pressure Weights Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Suction Line Liquid Line Power supply Max. running current Inrush current STD (2) Transport weight Operating weight 4202-B 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B kW kW n° 905 262 2 1015 296 2 1140 327 2 1282 364 2 1566 456 3 1733 498 3 1909 550 3 2168 631 3 n° n° l/s kPa DN Ø mm Ø mm V/Ph/Hz A A dB(A) Kg Kg 2 2 2 3 3 3 3 43.24 57 150 2 x 76 2 x 54 48.49 55 200 2 x 76 2 x 54 2 2 54.47 56 200 2 x 89 2 x 54 1433 417 2 Screw 2 61.25 52 200 2 x 89 2 x 54 74.82 78 250 3 x 76 3 x 54 82.8 57 250 3 x 89 3 x 54 91.21 67 250 3 x 89 3 x 54 103.58 95 250 3 x 89 3 x 54 558.4 732.2 74 3225 3480 641.8 915.9 78 3525 3980 739.8 1072.9 79 4445 4980 832.2 1199.1 83 4530 5040 68.47 69 200 2 x 89 2 x 54 400 / 3 / 50 935 1343.5 85 4600 5100 962.7 1236.8 80 4980 5570 1109.7 1442.8 82 6430 7130 1248.3 1615.2 83 6555 7290 1402.5 1811 87 6740 7440 3 DIMENSIONS MEA/Y L P H 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B STD STD STD mm mm mm 3300 800 1700 DIMENSIONAL 3300 800 1700 3700 800 1700 3700 800 1700 3700 800 1700 3800 1080 1700 4000 1080 2100 4000 1080 2100 4300 1080 2100 4300 1080 2100 4300 1080 2100 5100 1080 2100 5100 1080 2100 4800 1600 2100 5300 1600 2100 5300 1600 2100 3 5300 1600 2100 NOTES CLEREANCE AREA MEA/Y 1302÷9003 A mm B mm C (*) mm D mm 5100 1080 2100 MEA/Y 1302-B÷9003-B Cooling Cooling capacity (1) Absorbed power (1) Quantity Type Refrigerant circuits Capacity steps Water flow Pressure drops Water connections Suction Line Liquid Line Power supply Max. running current Inrush current STD (2) Transport weight Operating weight (1) 500 500 800 500 (2) (*) Chilled water from 12 to 7 °C, condensing temperature 50 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 113 3 RCA/K 4111÷8222 REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/K series are designed to be combined with evaporating units with R410A refrigerant (MEA/K). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/K MEA/K Standard unit RCA/K MEA/K FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 114 15 18 21 25 31 41 51 61 71 81 4111 4111 4111 4111 4111 4112 5111 5111 5112 5113 91 101 131 151 RCA/K 6111 6112 6113 5121 MEA/K 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P RCA/K 6114 6121 6122 6123 6124 6125 6131 6132 8221 8222 TECHNICAL DATA R410A RCA/K 4111÷8222 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCA/K 4111÷8222 Air flow Connections Electrical characteristics Condenser Transport weight m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) 4111 4112 5111 5112 5113 5121 6111 6112 6113 0.85 22 18 0.82 28 18 1.44 22 18 1.89 28 18 3.50 35 28 2.72 28 22 2.61 35 28 2.47 35 28 0.24 1.1 1 46 30 0.24 1.1 1 46 30 0.30 1.3 1 38 48 0.75 3.3 1 47 52 1.75 28 18 230/1/50 0.75 3.3 1 47 55 1.50 6.6 2 50 104 0.67 3.1 1 47 79 0.67 3.1 1 47 87 0.67 3.1 1 47 95 6114 6121 6122 6123 4.06 35 28 5.94 35 28 5.56 42 35 9.00 35 28 3.20 4.9 1 58 95 0.99 1.6 2 49 150 0.99 1.6 2 49 166 3.20 4.9 2 61 150 6124 6125 8.61 8.11 42 42 35 35 400/3/50 3.20 3.20 4.9 4.9 2 2 61 61 166 183 6131 6132 8221 8222 13.50 42 35 12.92 54 35 19.67 2x35 2x28 22.89 2x35 2x28 3.20 4.9 3 63 221 3.20 4.9 3 63 236 1.85 2.85 4 52 462 1.85 2.85 4 54 462 DIMENSIONS RCA/K L P H STD STD STD mm mm mm 4111 4112 5111 5112 5113 5121 6111 6112 6113 6114 6121 6122 6123 6124 6125 6131 6132 8221 8222 1130 900 980 1130 900 980 1130 900 980 1130 900 980 1130 900 980 1910 900 980 1490 1260 990 1490 1260 990 1490 1260 990 1490 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 3770 1260 990 3770 1260 990 3230 2400 1565 3230 2400 1565 DIMENSIONAL RCA/K 4111÷8222 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 NOTES (1) 4111÷8222 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 115 3 RCA/K/SL 4111÷8222 SILENCED REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/K series are designed to be combined with evaporating units with R410A refrigerant (MEA/K). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/K/SL MEA/K Silencied unit RCA/K/SL MEA/K FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 116 15 18 21 25 31 41 51 61 71 81 4111 4111 4111 4112 4113 5111 5112 5113 5121 5121 91 101 131 151 RCA/K/SL 5121 6111 6112 6120 MEA/K 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P RCA/K/SL 6121 6122 6123 6124 6131 6132 6133 6134 8221 8222 TECHNICAL DATA R410A RCA/K/SL 4111÷8222 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCA/K/SL 4111÷8222 Air flow Connections Electrical characteristics Condenser Transport weight 4111 4112 4113 5111 0.57 22 18 0.54 22 18 0.53 22 18 1.25 22 18 0.13 0.58 1 34 30 0.13 0.58 1 34 30 0.13 0.58 1 34 30 0.24 1.1 1 41 48 5113 1.44 1.33 22 28 18 18 230/1/50 0.30 0.30 1.3 1.3 1 1 41 41 48 52 5121 6111 6112 6120 2.92 28 22 2.61 35 28 2.47 35 28 5.47 35 28 0.60 2.6 2 44 89 0.67 3.1 1 47 87 0.67 3.1 1 47 95 1.34 6.2 2 49 150 6121 6122 4.72 4.39 35 42 28 35 400/3/50 0.99 0.99 1.6 1.6 2 2 43 43 150 166 6123 6124 6131 6132 6133 6134 8221 8222 6.94 35 28 6.67 42 35 8.92 42 35 10.42 42 35 10.00 54 35 9.17 54 35 18.11 2x35 2x28 22.89 2x42 2x35 3.20 4.9 2 55 150 3.20 4.9 2 55 166 0.99 1.6 3 45 221 3.20 4.9 3 57 221 3.20 4.9 3 57 236 3.20 4.9 3 57 270 1.85 2.85 4 47 462 1.85 2.85 4 54 502 m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) 5112 400/3/50 DIMENSIONS RCA/K/SL L P H STD STD STD mm mm mm 4111 4112 4113 5111 5112 5113 5121 6111 6112 6120 6121 6122 6123 6124 6131 6132 6133 6134 8221 8222 1130 900 980 1130 900 980 1130 900 980 1130 900 980 1130 900 980 1130 900 980 1910 900 980 1490 1260 990 1490 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 2630 1260 990 3770 1260 990 3770 1260 990 3770 1260 990 3770 1260 990 3230 2400 1565 3230 2400 1565 DIMENSIONAL RCA/K/SL 4111÷8222 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 NOTES (1) 4111÷8222 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 117 3 RCA/K/SSL 5111÷8222 SUPER SILENCED REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/K series are designed to be combined with evaporating units with R410A refrigerant (MEA/K). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/K/SSL MEA/K Super silencied unit RCA/K/SSL MEA/K FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 118 15 18 21 25 31 41 51 61 71 81 5111 5111 5111 5111 5111 5112 5112 6111 6111 6111 91 101 131 151 RCA/K/SSL 6112 6121 6121 6121 MEA/K 182-P 202-P 242-P 262-P 302-P 363-P 393-P 453-P 524-P 604-P RCA/K/SSL 6124 6131 6132 6133 6141 8121 8131 8132 8221 8222 TECHNICAL DATA R410A RCA/K/SSL 5111÷8222 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCA/K/SSL 5111÷8222 Air flow Connections Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) 5112 6111 6112 6121 0.90 22 18 0.94 28 18 1.81 35 28 3.97 35 28 0.13 0.59 1 34 48 0.14 0.68 1 34 52 1.97 28 22 230/1/50 0.33 1.6 1 39 79 0.33 1.6 1 39 95 0.66 3.2 2 41 150 m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 6124 6131 6132 6133 3.89 42 35 4.83 42 35 6.25 42 35 5.83 54 35 0.99 1.6 2 42 166 0.99 1.6 3 36 221 0.99 1.6 3 44 221 0.99 1.6 3 44 236 6141 8121 8.33 7.44 35 42 28 35 400/3/50 0.99 0.84 1.6 1.4 4 2 45 43 292 324 8131 8132 8221 8222 14.08 42 35 11.92 54 42 16.67 2x35 2x28 22.89 2x35 2x28 0.84 1.4 3 45 413 0.84 1.4 3 45 447 0.84 1.4 4 45 462 1.85 2.85 4 54 462 DIMENSIONS RCA/K/SSL L P H STD STD STD mm mm mm 5111 5112 6111 6112 6121 6124 6131 6132 6133 6141 8121 8131 8132 8221 8222 1130 900 980 1130 900 980 1490 1260 990 1490 1260 990 2630 1260 990 2630 1260 990 3770 1260 990 3770 1260 990 3770 1260 990 4910 1260 990 3230 1380 1565 4580 1380 1565 4580 1380 1565 3230 2400 1565 3230 2400 1565 DIMENSIONAL RCA/K/SSL 5111÷8222 Connections 5111 m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 NOTES (1) 5111÷8222 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 119 3 RCA/Y 8141÷9282 REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/Y series are designed to be combined with evaporating units with R134a refrigerant (MEA/Y). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/Y MEA/Y 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B RCA/Y 8141 8151 8161 8171 8172 8251 8261 8271 8281 8282 MEA/Y 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B RCA/Y 9261 9271 9281 9282 3x8251 3x8252 3x8262 3x8272 Standard unit FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 120 TECHNICAL DATA R134a RCA/Y 8141÷9282 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCA/Y 8141÷9282 Air flow Connections Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 8141 8151 8161 8171 8172 8251 8252 8261 8262 20.44 2X64 2x42 25.56 2X64 2x42 30.67 2X76 2x42 38.11 2X76 2x54 49.17 2X64 2x42 52.78 2X64 2x42 63.33 2X76 2x42 59.00 2X76 2x42 7.40 11.4 4 55 637 9.25 14.25 5 56 794 11.10 17.1 6 57 950 12.95 19.95 7 57 1027 35.78 2X76 2x54 400/3/50 12.95 19.95 7 57 1107 9.25 14.25 10 58 1325 9.25 14.25 10 58 1222 11.10 17.1 12 59 1461 11.10 17.1 12 59 1585 8271 8272 8281 8282 9261 9271 9281 9282 73.89 2X76 2x54 68.83 2X76 2x54 84.44 2X76 2x54 78.67 2X76 2x54 82.33 2X76 2X64 96.06 2X76 2X64 109.78 2X76 2X64 127.56 2X76 2X64 12.95 19.95 14 59 1702 12.95 19.95 14 59 1845 14.80 22.8 16 60 1942 14.80 22.8 16 60 2106 12.60 19.2 12 57 3056 14.70 22.4 14 57 3515 16.80 25.6 16 58 3974 16.80 25.6 16 58 3974 400/3/50 DIMENSIONS RCA/Y L P H STD STD STD mm mm mm 8141 8151 8161 8171 8172 8251 8252 8261 8262 8271 8272 8281 8282 9261 9271 9281 9282 5930 1380 1565 7280 1380 1565 8630 1380 1565 9980 1380 1565 9980 1380 1565 7280 2400 1565 7280 2400 1565 8630 2400 1565 8630 2400 1565 9980 2400 1565 9980 2400 1565 11330 2400 1565 11330 2400 1565 7990 2400 2262 9240 2400 2262 10490 2400 2262 10490 2400 2262 DIMENSIONAL RCA/Y 8141÷9282 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 NOTES (1) 9261÷9282 8141÷8282 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 121 3 RCA/Y/SL 8231÷9252 SILENCED REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/Y series are designed to be combined with evaporating units with R134a refrigerant (MEA/Y). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/Y/SL MEA/Y 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B RCA/Y/SL 8231 8232 8241 8242 8251 8261 8271 8281 9261 9271 MEA/Y 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B RCA/Y/SL 9281 9282 2x8272 2x8282 3x9171 3x9172 3x9251 3x9252 Silencied unit FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 122 TECHNICAL DATA R134a RCA/Y/SL 8231÷9252 Air flow Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) RCA/Y/SL 8231÷9252 Air flow Connections Electrical characteristics Condenser Transport weight IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 8231 8232 8241 8242 8251 8261 8271 8272 8281 24.67 2x54 2x42 22.50 2x54 2x42 32.89 2x54 2x35 30.00 2x54 2x42 49.33 2X76 2x42 57.56 2X76 2x54 52.50 2X76 2x54 65.78 2X76 2x54 5.55 8.55 6 49 742 5.55 8.55 6 49 804 7.40 11.4 8 50 982 7.40 11.4 8 50 1065 41.11 2X64 2x42 400/3/50 9.25 14.25 10 51 1222 11.10 17.1 12 52 1461 12.95 19.95 14 52 1702 12.95 19.95 14 52 1845 14.8 22.8 16 53 1942 8282 9171 9172 9251 9252 9261 9271 9281 9282 60.00 2X76 2x54 45.50 2X76 2x54 43.53 2X76 2x54 57.22 2X76 2x54 64.67 2X76 2x54 75.44 2X76 2X64 86.22 2X76 2X64 101.33 2X76 2X64 14.80 22.8 16 53 2106 14.70 22.4 7 48 1747 14.70 22.4 7 48 1902 10.50 16 10 50 2451 53.89 2X76 2x54 400/3/50 10.50 16 10 50 2597 12.60 19.2 12 51 3056 14.70 22.4 14 51 3515 16.80 25.6 16 52 3974 16.80 25.6 16 63 3974 DIMENSIONS RCA/Y/SL L P H STD STD STD mm mm mm 8231 8232 8241 8242 8251 8261 8271 8272 8281 8282 9171 9172 9251 9252 9261 9271 9281 9282 4580 2400 1565 4580 2400 1565 5930 2400 1565 5930 2400 1565 7280 2400 1565 8630 2400 1565 9980 2400 1565 9980 2400 1565 11330 2400 1565 11330 2400 1565 10275 1170 1804 10275 1170 1804 6740 2400 2262 6740 2400 2262 7990 2400 2262 9240 2400 2262 10490 2400 2262 10490 2400 2262 DIMENSIONAL RCA/Y/SL 8231÷9252 Connections m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg 3 NOTES (1) 9171÷9252 8231÷8282 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 123 3 RCA/Y/SSL 8151÷9281 SUPER SILENCED REMOTE AIR CONDENSER WITH AXIAL FANS. UNIT DESCRIPTION The remote air-cooled condensers with axial fans of the RCA/Y series are designed to be combined with evaporating units with R134a refrigerant (MEA/Y). These units, available in three configurations depending on the degree of noiselessness required: Standard, Silent (SL) and Super Silent (SSL), are equipped with latest generation axial fans, with motor fan shrouds having a large radius of curvature to eliminate all the air flow turbulence, and larger plenum to uniform the air distribution on the cooling battery. These units can be installed with either horizontal or vertical air delivery, as needed. VERSIONS COMBINATIONS RCA/Y/SSL MEA/Y 1302-B 1502-B 1702-B 1902-B 2002-B 2602-B 2802-B 3002-B 3602-B 4202-B RCA/Y/SSL 8151 8161 8171 8251 8251 8261 8272 8282 9271 9272 MEA/Y 4402-B 4802-B 5402-B 6002-B 6603-B 7203-B 8103-B 9003-B RCA/Y/SSL 9281 2x8271 2x8281 2x8282 3x8261 3x8271 3x8272 3x8281 Super silencied unit FEATURES • Frame in oven painted with a polyurethane resin and galvanised steel casework. • The cowlings of the motorfans are made with a wide bending radius to eliminate any turbulence in the airflow. • Heat exchanger is made with corrugated tubes with a greater heat exchange surface, fins cut with a special louver configuration to give the best external coefficient of heat exchange. ACCESSORIES Factory fitted accessories: SD Wiring integrated in a branch circuit box FR Rotation regulator Loose accessories: SVV Supports for vertical air flow versions 124 TECHNICAL DATA R134a RCA/Y/SSL 8151÷8272 Electrical characteristics Condenser m³/s Ø mm Ø mm V/Ph/Hz kW A n° dB(A) Kg IN OUT Power supply Absorbed power Absorbed current Fans Sound pressure (1) Transport weight 8161 8171 8251 8261 8271 8272 8281 8282 9271 9272 9281 18.61 2X64 2x42 22.33 2X76 2x42 26.06 2X76 2x54 38.06 2X64 2x42 42.33 2X76 2x42 60.89 2x54 2x54 56.44 2x54 2x54 73.89 2X76 2X64 70.00 2X76 2X64 80.00 2X76 2X64 4.20 7 5 47 794 5.04 8.4 6 48 950 5.88 9.8 7 48 1107 4.20 7 10 49 1222 5.04 8.4 12 50 1585 53.28 49.39 2X76 2X76 2x54 2x54 400/3/50 5.88 5.88 9.8 9.8 14 14 50 50 1702 1845 6.72 11.2 16 51 1942 6.72 11.2 16 51 2106 11.06 17.5 14 50 3309 11.06 17.5 14 50 3515 12.64 20 16 51 3974 DIMENSIONS RCA/Y/SSL L P H STD STD STD mm mm mm 8151 8161 8171 8251 8261 8271 8272 8281 8282 9271 9272 9281 7280 1380 1565 8630 1380 1565 9980 1380 1565 7280 2400 1565 8630 2400 1565 9980 2400 1565 9980 2400 1565 11330 2400 1565 11330 2400 1565 9240 2400 2262 9240 2400 2262 10490 2400 2262 DIMENSIONAL RCA/Y/SSL 8151÷8272 Air flow Connections 8151 3 NOTES (1) 9271÷9281 8151÷8282 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. N.B. Combinations are made at 50°C of Condensing Temperature, Ambient air temperature 35°C. 125 3 MR 1500-2500 REMOTE HYDRONIC MODULES WITH PUMP KIT. FROM 1500 lt. AND 2500 lt. UNIT DESCRIPTION The remote hydronic modules with pumping group of the MR 15002500 series are intended to solve technical problems resulting from thermal inertia in air conditioning systems for both residential and industrial use. Installing a tank for cooled water allows units to reduce the operating cycles of the compressors, thus extending the useful life of the machines. It also results in a greater capacity of the system itself, a remarkable operational saving even using machines with reduced capacities and a greater flexibility, being able to work with temperatures other than the design temperatures. The tanks are made in peraluman and zinc-coated plate with a capacity of 1500 and 2500 litres; they are available with circulation pump or double circulation pump accessory and are complete with all the components necessary for a quick onsite installation. VERSIONS MR 1500 With 1500 lt. MR 2500 With 2500 lt. 126 FEATURES ACCESSORIES • Self-supporting frame in peraluman and galvanized steel frame further protected with polyester powder painting. Easy to remove panels allow access to the inside of the unit for maintenance and other necessary operations. • Electrical board. Present only with the accessories circulating pump, it includes: - main switch with door safety interlock; automatic switches for protection of circulating pumps, of secondary circuit and of antifreeeze heaters, signalling lamps, interface relay and clamps for external connections. • Water circuit. Includes: insulated inertial tank, safety valve, automatic air release valves, expansion vessel, guage, automatic filling group, plant charge and discharge water shut off valve. Factory fitted accessories: PU1-PU5 Single circulating pump PD1-PD5 Double circulating pump FS Antifreeze heater tank FU Antifreeze heater tank and single pump FD Evaporator heater for SPD TECHNICAL DATA H2O 1500 2500 Storage water volume l Expansion vessel l Safety valve bar Water connections ”G STD Kg STD+PU1 Kg STD+PU2 Kg STD+PU3 Kg STD+PU4 Kg Transport weight STD+PU5 Kg STD+PD1 Kg STD+PD2 Kg STD+PD3 Kg STD+PD4 Kg STD+PD5 Kg STD Kg STD+PU1 Kg STD+PU2 Kg STD+PU3 Kg STD+PU4 Kg Operating weight STD+PU5 Kg STD+PD1 Kg STD+PD2 Kg STD+PD3 Kg STD+PD4 Kg STD+PD5 Kg PUMP ELECTRICAL CHARACTERISTICS PU1 kW PU2 kW Nominal PU3 kW absorbed power PU4 kW PU5 kW PU1 A PU2 A Max runnnig PU3 A current PU4 A PU5 A 1500 2x25 3 4” 470 513 569 569 634 740 586 696 696 826 1055 1970 2014 2070 2070 2135 2241 2088 2198 2198 2328 2557 2500 3x25 3 4” 520 565 617 617 686 796 638 740 740 878 990 3020 3066 3118 3118 3187 3297 3140 3242 3242 3380 3492 3 5.5 7.5 15 22 5.6 11 14.6 28.6 40.3 3 5.5 7.5 15 22 5.6 11 14.6 28.6 40.3 Pumping kit DIMENSIONS MR L P H STD STD STD mm mm mm DIMENSIONAL 1500 2500 1900 2260 1780 1900 2260 1780 MR 1500-2500 MR 1500-2500 3 CLEREANCE AREA MR 1500-2500 A B C D mm mm mm mm 800 800 800 800 127 4 INDEX Roof Top and condensing units INDEX RTA/K/WP 182-R÷453-R RTA/K 182÷804 RTA/K/MS 182÷804 RTA/K/ECO 182÷804 RTA/K/ECO/REC-FX 182÷804 MHA/K 15÷151 MHA/K 182÷604 MRA/K 15÷131 MRA/K 182÷604 Page 130 - 131 132 - 133 134 - 135 136 - 137 138 - 139 140 - 141 142 - 143 144 - 145 146 - 147 4 129 4 RTA/K/WP 182-R÷453-R ROOF TOP WITH SINGLE PANEL, SCROLL COMPRESSORS AND PLUG-FANS. FROM 65 kW TO 171 kW. UNIT DESCRIPTION The “Roof Top” single unit autonomous air conditioners for outdoor installation from the series AIRPLUS, which can be connected to a network of ducts for air distribution, are ideal for air conditioning of medium surfaces for civil use such as buildings, shopping centres, canteens, restaurants and stores, or for areas for industrial use, such as centres for the processing and conservation of food products. Equipped with a frame with extruded aluminium profiles and prepainted panels, as well as Scroll compressors with R410A coolant, they are available in a version with FREE COOLING reversible heat pump with 2 or 3 shutters. AIRPLUS is equipped with PLUG-FANS with high energy efficiency backward blades both for intake as well as output, which are managed by an electronic device adjusting rotational speed of the fans to adapt the air flow to the system capacity. The unit can easily adapt to diverse engineering needs thanks to the possibility of positioning the unit onsite and selecting the air flow direction from 8 different intake positions and 8 different output positions. Furthermore,the unit has flat type filters with varying efficiency levels, maintaining adequate air quality and guaranteeing high comfort levels. VERSIONS RTA/K/WP Standard unit RTA/K/WP/MS Unit with Free-Cooling with 2 shutters RTA/K/WP/ECO Unit with Free-Cooling with 3 shutters 130 MS - ECO MS - Free-Cooling with 2 shutters - Further to components of the basic versionn, includes: two wing profile aluminium dampers with spring return servomotors. ECO - Free-Cooling with 2 shutters - Further to components of the basic version, includes: return air PLUG-FAN fan; motorized wing profile aluminium dampers, the opposite movement is ensured by transmission of nylon gear. Supply, return and fresh air are controlled through the microprocessor fitted in the base unit; this microprocessor, according to the temperature of the return and fresh air, modulates the opening of the dampers and controls the refrigerant circuit capacity steps to ensure comfort conditions of the handled air. The adjustments of the ECO versions are automatically controlled both in free-cooling and free-heating mode. FEATURES ACCESSORIES • Structure of base perimeter made of steel sheet elements galvanised, passive treated and mould folded. The frame is made of extruded aluminium alloy profiles connected by 3 way joints. The assembling of the base to the frame is of dual support and grants the walking on the base panels installation of which is effected without sticking out screws. Water proofing is granted by gaskets having shape memory for perfect seal up even after repeated removals. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser et evaporator with copper tube and aluminium finned coil. • Reverse blade PLUG-FANS delivery and intake ventilation system, high energy efficiency, with electronic speed control to adapt easily to the system characteristics. • The air treatment section has removable panels allow selection of intake and output configurations that adapt to the specific needs of the system. • R410A refrigerant. • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermo contacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit. • Microprocessor for the automatic control of the unit. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C FT Filter section with efficiency F6-F7-F8 RF Cooling circuit shut off valves WS2 2-row water coil for heating with three way valve EH Electrical coil CH Enthalpic control (only for ECO) EX External air intake shutter AT Self-adjusting power device SQ Air quality sensor PF Differential pressostat filters control CP Potential free contacts Loose accessories: MN High and low gauges CS Shutter protection caps CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A RTA/K/WP 182-R÷453-R 202-R 242-R 262-R 302-R 363-R 393-R 453-R 64.9 20.9 62.9 18.6 2.5 200 73.8 24.2 71.1 21.7 2.78 200 85.6 27.2 81.2 25.2 3.34 200 96.8 30 92.9 28.1 3.61 200 110.9 35.4 106.8 31 4.44 200 128.3 41.1 122.8 38.1 4.44 200 147.3 45.9 142.2 42.6 5.83 200 171.4 54.1 162.1 50.1 6.67 200 G4 3.55 100 2 Plug-Fan 2 G4 3.55 100 2 Plug-Fan 3 G4 4.72 100 2 Plug-Fan 3 G4 5.33 100 2 Plug-Fan 3 1 2 2 7.7 1 3 2 9.7 1 3 2 11.4 1 3 3 15.7 215 91 84.9 43 2.03 18 2 242 110 103.1 68 2.46 24 2 260 131 109.9 86 2.62 28 2 40 59 4 60 1570 1610 1660 40 59 4 61 1920 1940 1990 48 69 4 61 2020 2060 2110 2 Plug-Fan G4 2 100 2 Plug-Fan 2 G4 2.22 100 2 Plug-Fan 2 G4 2.67 100 2 Plug-Fan 2 G4 2.89 100 2 Plug-Fan 2 1 2 1 4.7 1 2 1 4.7 1 2 2 6.9 1 2 2 6.7 190 53 65.4 16 1.56 12 2 165 56 68.6 19 1.64 14 2 188 65 74.9 26 1.79 15 2 21 30 2 56 1280 1320 1370 27 39 2 56 1315 1350 1400 27 39 2 60 1370 1395 1445 Scroll 400 / 3 / 50 201 208 69 79 78.9 84.9 30 43 1.89 2.03 17 18 2 2 400 / 3 / 50 27 40 39 59 2 4 60 60 1380 1475 1415 1515 1465 1565 RTA/K/WP 182-R÷453-R Cooling capacity (1) kW Absorbed power (1),(2) kW Heating capacity (3) kW Heating Absorbed power (2),(3) kW Air flow m³/s static pressure Pa Air treatment Fans n° section Type Filters Air flow m³/s static pressure Pa Air intake section Fans n° Type Compressors n° Type Refrigerant circuits n° Condening section Capacity steps n° Fans n° Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Heating capacity (4) kW Air pressure drops Pa Hot water coil Water flow (4) l/s Water pressure drops kPa Water connections ”G Power supply V/Ph/Hz Heating capacity kW Electric heating Max absorbed current A Steps n° Sound pressure STD (5) dB(A) STD Kg Transport weight MS Kg ECO Kg Cooling 182-R DIMENSIONS RTA/K/WP L P H STD STD STD mm mm mm 182-R 202-R 242-R 262-R 302-R 363-R 393-R 453-R 2930 2200 2370 2930 2200 2370 2930 2200 2370 2930 2200 2370 2930 2200 2370 2930 2200 2370 3930 2200 2370 3930 2200 2370 DIMENSIONAL NOTES CLEREANCE AREA RTA/K/WP 182-R÷453-R A B (*) C D mm mm mm mm 800 1700 800 800 (1) (2) (3) (4) (5) (*) 4 Evaporator inlet air temperature 27 °C d.b. 19 °C w.b.; Ambient air temperature 35 °C; Excluded the power absorbed by Plugfans. Condensator inlet air temperature 20 °C; Ambient air temperature 7 °C d.b./6 °C w.b. Inlet air temperature 20 °C; Inlet water temperature 70 °C; Outlet water temperature 60 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. B SIDE: Coil side. 131 4 RTA/K 182÷804 ROOF TOP WITH SANDWICH PANELS WITH SCROLL COMPRESSORS. FROM 58 kW TO 252 kW. UNIT DESCRIPTION The outdoor “Roof Top” self-contained air conditioning units of the RTA/K series, with R410A refrigerant, which can be connected to a duct network for air distribution, are ideal for the air conditioning of large surface areas for public use such as halls, shopping centres, cafeterias, restaurants and health centres, or for industrial environments such as food processing or preservation centres. Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in a cooling-only version and a version with reversible heat pump. They have a high degree of modularity and adaptability to every plant-engineering need since, in addition to the basic versions, it is also possible to add various solutions for the air treatment sections: mixing chamber, FREECOOLING, cross-flow heat recuperator, humidifier, hot air generator, etc. The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards. VERSIONS RTA/K Standard unit FEATURES ACCESSORIES • Structure of base perimeter made of steel sheet elements galvanised, passive treated and mould folded (3 mm thick). The frame is made of extruded aluminium alloy profiles connected by 3 way joints. The assembling of the base to the frame is of dual support and grants the walking on the base panels installation of which is effected without sticking out screws. 50 mm thick sandwich panels are made of prepainted steel sheet; water proofing is granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser et evaporator with copper tube and aluminium finned coil. • Delivery and intake centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • R410A refrigerant. • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermo contacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit. • Microprocessor for the automatic control of the unit. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C FT Bag filter with F6-F7-F8 efficiency FT/R Rigid bag filter with F6-F7-F8 efficiency RF Cooling circuit shut off valves WS2 2-row water coil for heating with three way valve EH Electrical coil SQ Air quality sensor PF Differential pressostat filters control CP Potential free contacts RP Metallic guards for condenser COMPLEMENTARY SECTIONS UMI UMI/EN F/CD 132 Section with preparation for Humidifier Section humidifier with electrodes immersed Condensation endothermic hot air generator with modulating gas burner Loose accessories: MN High and low gauges CS Shutter protection caps CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A 182 202 242 262 302 Cooling capacity (1) kW Absorbed power (1),(2) kW Heating capacity (3) kW Heating Absorbed power (2),(3) kW Air flow m³/s static pressure Pa Air treatment section Fans n° Filters Compressors n° Type Refrigerant circuits n° Condening section Capacity steps n° Fans n° Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Heating capacity (4) kW Air pressure drops Pa Hot water coil Water flow (4) l/s Water pressure drops kPa Water connections ”G Power supply V/Ph/Hz Heating capacity kW Electric heating Max absorbed current A Steps n° Sound pressure STD (5) dB(A) Transport weight STD Kg 57.9 19.4 60.2 16.8 2.67 250 65.8 21.8 67.2 17.9 3.3 250 77.6 24 76.8 20.2 4.05 250 87.4 26.2 88.6 22.8 4.05 250 98.6 30.8 100.9 25.2 4.84 250 G4 2 G4 2 G4 2 G4 2 G4 2 1 2 2 6.9 1 2 2 7.1 1 2 2 6.9 1 2 2 6.7 1 2 2 6.7 50 173 85 30 2.03 45 1­”½ 53 175 100 31 2.39 47 1­”½ 63 186 125 31 2.99 48 1”­½ 67 199 125 31 2.99 48 1”­½ 76 243 150 31 3.58 49 1”­½ 15 22 2 58 1030 21 30 2 58 1085 27 39 2 58 1180 27 39 2 58 1280 27 39 2 58 1300 Cooling 363 393 453 524 604 804 113.1 128.9 37.8 40.4 114.7 132.8 32.2 34 5.49 6.32 250 250 1 G4 G4 3 3 Scroll 1 1 3 3 2 4 9.8 14 400 / 3 / 50 94 100 218 232 175 200 30 36 4.18 4.78 44 51 2” 2” 400 / 3 / 50 41 41 59 59 4 4 59 60 1540 1900 144.9 43.3 151.1 40 6.32 250 168 54.6 172.6 45.7 8.2 250 197.7 61.5 203.8 50.4 9.79 250 251.6 85.1 261.8 70.5 12.31 250 G4 3 G4 4 G4 4 G4 4 1 3 4 13.9 2 4 4 13.9 2 4 4 13.4 2 4 4 20 109 276 200 36 4.78 51 2” 133 265 250 35 5.97 53 2” 150 317 300 35 7.17 57 2”½ 173 347 350 35 8.36 55 2”1/2 41 59 4 60 1950 41 59 4 61 2270 48 69 4 61 2480 55 79 4 62 3320 RTA/K 182÷804 RTA/K 182÷804 DIMENSIONS RTA/K L P H STD STD STD mm mm mm 182 202 242 262 302 363 393 453 524 604 804 2980 2200 2100 3080 2200 2340 3190 2200 2340 3190 2200 2340 3290 2200 2340 3770 2200 2340 4500 2200 2340 4500 2200 2340 5150 2200 2340 5300 2200 2510 7370 2200 2510 DIMENSIONAL NOTES CLEREANCE AREA (1) RTA/K 182÷363 A mm B mm C mm D (*) mm 800 800 800 1700 RTA/K 393÷804 A (**) mm B mm C mm D mm 1000 1700 800 1700 (2) (3) (4) (5) (*) (**) 4 Evaporator inlet air temperature 27 °C d.b. 19 °C w.b.; Ambient air temperature 35 °C; Excluded the power absorbed by centrifugal fans. Condensator inlet air temperature 20 °C; Ambient air temperature 7 °C d.b./6 °C w.b. Inlet air temperature 20 °C; Inlet water temperature 70 °C; Outlet water temperature 60 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Coil side. A SIDE: Electrical board side. 133 4 RTA/K/MS 182÷804 ROOF TOP WITH SANDWICH PANELS WITH SCROLL COMPRESSORS AND MIXING BOX. FROM 58 kW TO 252 kW. UNIT DESCRIPTION The outdoor “Roof Top” self-contained air conditioning units of the RTA/K series, with R410A refrigerant, which can be connected to a duct network for air distribution, are ideal for the air conditioning of large surface areas for public use such as halls, shopping centres, cafeterias, restaurants and health centres, or for industrial environments such as food processing or preservation centres. Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in a cooling-only version and a version with reversible heat pump. They have a high degree of modularity and adaptability to every plant-engineering need since, in addition to the basic versions, it is also possible to add various solutions for the air treatment sections: mixing chamber, FREECOOLING, cross-flow heat recuperator, humidifier, hot air generator, etc. The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards. VERSIONS RTA/K/MS Standard unit with mixing box MS - Mixing box. Further to components of the basic section, includes: two wing profile aluminium dampers with spring return servomotors, the opposite movement is ensured by transmission of nylon gear. FEATURES ACCESSORIES • Structure of base perimeter made of steel sheet elements galvanised, passive treated and mould folded (3 mm thick). The frame is made of extruded aluminium alloy profiles connected by 3 way joints. The assembling of the base to the frame is of dual support and grants the walking on the base panels installation of which is effected without sticking out screws. 50 mm thick sandwich panels are made of prepainted steel sheet; water proofing is granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser et evaporator with copper tube and aluminium finned coil. • Delivery and intake centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • R410A refrigerant. • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermo contacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit. • Microprocessor for the automatic control of the unit. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C FT Bag filter with F6-F7-F8 efficiency FT/R Rigid bag filter with F6-F7-F8 efficiency RF Cooling circuit shut off valves WS2 2-row water coil for heating with three way valve EH Electrical coil SQ Air quality sensor PF Differential pressostat filters control CP Potential free contacts RP Metallic guards for condenser COMPLEMENTARY SECTIONS UMI UMI/EN F/CD 134 MIXING BOX Section with preparation for Humidifier Section humidifier with electrodes immersed Condensation endothermic hot air generator with modulating gas burner Loose accessories: MN High and low gauges CS Shutter protection caps CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A 182 202 242 262 302 Cooling capacity (1) kW Absorbed power (1),(2) kW Heating capacity (3) kW Heating Absorbed power (2),(3) kW Air flow m³/s static pressure Pa Air treatment section Fans n° Filters Compressors n° Type Refrigerant circuits n° Condening section Capacity steps n° Fans n° Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Heating capacity (4) kW Air pressure drops Pa Hot water coil Water flow (4) l/s Water pressure drops kPa Water connections ”G Power supply V/Ph/Hz Heating capacity kW Electric heating Max absorbed current A Steps n° Sound pressure STD (5) dB(A) Transport weight STD Kg 57.9 19.4 60.2 16.8 2.67 250 65.8 21.8 67.2 17.9 3.3 250 77.6 24 76.8 20.2 4.05 250 87.4 26.2 88.6 22.8 4.05 250 98.6 30.8 100.9 25.2 4.84 250 G4 2 Scroll 1 2 2 6.9 G4 2 Scroll 1 2 2 7.1 G4 2 Scroll 1 2 2 6.9 G4 2 Scroll 1 2 2 6.7 50 173 85 30 2.03 45 1­”½ 53 175 100 31 2.39 47 1­”½ 63 186 125 31 2.99 48 1”­½ 67 199 125 31 2.99 48 1”­½ 15 22 2 58 1110 21 30 2 58 1170 27 39 2 58 1285 27 39 2 58 1380 Cooling 363 393 453 524 604 804 113.1 128.9 37.8 40.4 114.7 132.8 32.2 34 5.49 6.32 250 250 1 G4 G4 G4 2 3 3 Scroll Scroll Scroll 1 1 1 2 3 3 2 2 4 6.7 9.8 14 400 / 3 / 50 76 94 100 243 218 232 150 175 200 31 30 36 3.58 4.18 4.78 49 44 51 1”­½ 2” 2” 400 / 3 / 50 27 41 41 39 59 59 2 4 4 58 59 60 1400 1610 2000 144.9 43.3 151.1 40 6.32 250 168 54.6 172.6 45.7 8.2 250 197.7 61.5 203.8 50.4 9.79 250 251.6 85.1 261.8 70.5 12.31 250 G4 3 Scroll 1 3 4 13.9 G4 4 Scroll 2 4 4 13.9 G4 4 Scroll 2 4 4 13.4 G4 4 Scroll 2 4 4 20 109 276 200 36 4.78 51 2” 133 265 250 35 5.97 53 2” 150 317 300 35 7.17 57 2”½ 173 347 350 35 8.36 55 2”1/2 41 59 4 60 2050 41 59 4 61 2370 48 69 4 61 2600 55 79 4 62 3570 RTA/K/MS 182÷804 RTA/K/MS 182÷804 DIMENSIONS RTA/K/MS L P H STD STD STD mm mm mm 182 202 242 262 302 363 393 453 524 604 804 3430 2200 2100 3530 2200 2340 3640 2200 2340 3640 2200 2340 3740 2200 2340 4220 2200 2340 4950 2200 2340 4950 2200 2340 5600 2200 2340 5750 2200 2510 7850 2200 2510 DIMENSIONAL NOTES CLEREANCE AREA (1) RTA/K/MS 182÷363 A mm B mm C mm D (*) mm 800 800 800 1700 RTA/K/MS 393÷804 A (**) mm B mm C mm D mm 1000 1700 800 1700 (2) (3) (4) (5) (*) (**) 4 Evaporator inlet air temperature 27 °C d.b. 19 °C w.b.; Ambient air temperature 35 °C; Excluded the power absorbed by centrifugal fans. Condensator inlet air temperature 20 °C; Ambient air temperature 7 °C d.b./6 °C w.b. Inlet air temperature 20 °C; Inlet water temperature 70 °C; Outlet water temperature 60 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Coil side. A SIDE: Electrical board side. 135 4 RTA/K/ECO 182÷804 ROOF TOP WITH SANDWICH PANELS WITH SCROLL COMPRESSORS AND ECONOMIZER. FROM 58 kW TO 252 kW. UNIT DESCRIPTION The outdoor “Roof Top” self-contained air conditioning units of the RTA/K series, with R410A refrigerant, which can be connected to a duct network for air distribution, are ideal for the air conditioning of large surface areas for public use such as halls, shopping centres, cafeterias, restaurants and health centres, or for industrial environments such as food processing or preservation centres. Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in a cooling-only version and a version with reversible heat pump. They have a high degree of modularity and adaptability to every plant-engineering need since, in addition to the basic versions, it is also possible to add various solutions for the air treatment sections: mixing chamber, FREECOOLING, cross-flow heat recuperator, humidifier, hot air generator, etc. The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards. The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards. VERSIONS RTA/K/ECO Standard unit with economizer FEATURES • Structure of base perimeter made of steel sheet elements galvanised, passive treated and mould folded (3 mm thick). The frame is made of extruded aluminium alloy profiles connected by 3 way joints. The assembling of the base to the frame is of dual support and grants the walking on the base panels installation of which is effected without sticking out screws. 50 mm thick sandwich panels are made of prepainted steel sheet; water proofing is granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser et evaporator with copper tube and aluminium finned coil. • Delivery and intake centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • R410A refrigerant. • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermo contacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit. • Microprocessor for the automatic control of the unit. COMPLEMENTARY SECTIONS UMI UMI/EN F/CD 136 Section with preparation for Humidifier Section humidifier with electrodes immersed Condensation endothermic hot air generator with modulating gas burner ECO ECO - Economizer. Further to components of the basic section, includes: return air fan with electrical motor, complete of adjustable transmission, mounted on elastic supports; motorized wing profile aluminium dampers, the opposite movement is ensured by transmission of nylon gear. Supply, return and fresh air are controlled through the microprocessor fitted in the base unit; this microprocessor, according to the temperature of the return and fresh air, modulates the opening of the dampers and controls the refrigerant circuit capacity steps to ensure comfort conditions of the handled air. The adjustments of the ECO versions are automatically controlled both in free-cooling and freeheating mode. ACCESSORIES Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C FT Bag filter with F6-F7-F8 efficiency FT/R Rigid bag filter with F6-F7-F8 efficiency RF Cooling circuit shut off valves WS2 2-row water coil for heating with three way valve EH Electrical coil SQ Air quality sensor PF Differential pressostat filters control CP Potential free contacts RP Metallic guards for condenser Loose accessories: MN High and low gauges CS Shutter protection caps CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A 182 202 242 262 302 Cooling capacity (1) kW Absorbed power (1),(2) kW Heating capacity (3) kW Heating Absorbed power (2),(3) kW Air flow m³/s static pressure Pa Air treatment section Fans n° Filters Air flow m³/s Air intake section static pressure Pa Fans n° Compressors n° Type Refrigerant circuits n° Condening section Capacity steps n° Fans n° Air flow m³/s Power supply V/Ph/Hz Electrical Max. running current A characteristics Inrush current A Heating capacity (4) kW Air pressure drops Pa Hot water coil Water flow (4) l/s Water pressure drops kPa Water connections ”G Power supply V/Ph/Hz Heating capacity kW Electric heating Max absorbed current A Steps n° Sound pressure STD (5) dB(A) Transport weight STD Kg 57.9 19.4 60.2 16.8 2.67 250 65.8 21.8 67.2 17.9 3.3 250 77.6 24 76.8 20.2 4.05 250 87.4 26.2 88.6 22.8 4.05 250 98.6 30.8 100.9 25.2 4.84 250 G4 2.67 100 1 2 G4 3.3 100 1 2 G4 4.05 100 1 2 G4 4.05 100 1 2 G4 4.84 100 1 2 1 2 2 6.9 1 2 2 7.1 1 2 2 6.9 1 2 2 6.7 1 2 2 6.7 50 173 85 30 2.03 45 1­”½ 53 175 100 31 2.39 47 1­”½ 63 186 125 31 2.99 48 1”­½ 67 199 125 31 2.99 48 1”­½ 76 243 150 31 3.58 49 1”­½ 15 22 2 58 1570 21 30 2 58 1690 27 39 2 58 1810 27 39 2 58 1910 27 39 2 58 1930 Cooling 363 393 453 524 604 804 113.1 128.9 37.8 40.4 114.7 132.8 32.2 34 5.49 6.32 250 250 1 G4 G4 5.49 6.32 100 100 1 1 3 3 Scroll 1 1 3 3 2 4 9.8 14 400 / 3 / 50 94 100 218 232 175 200 30 36 4.18 4.78 44 51 2” 2” 400 / 3 / 50 41 41 59 59 4 4 59 60 2160 2560 144.9 43.3 151.1 40 6.32 250 168 54.6 172.6 45.7 8.2 250 197.7 61.5 203.8 50.4 9.79 250 251.6 85.1 261.8 70.5 12.31 250 G4 6.32 100 1 3 G4 8.2 100 1 4 G4 9.79 100 1 4 G4 12.31 100 1 4 1 3 4 13.9 2 4 4 13.9 2 4 4 13.4 2 4 4 20 109 276 200 36 4.78 51 2” 133 265 250 35 5.97 53 2” 150 317 300 35 7.17 57 2”½ 173 347 350 35 8.36 55 2”1/2 41 59 4 60 2610 41 59 4 61 3130 48 69 4 61 3500 55 79 4 62 4520 RTA/K/ECO 182÷804 RTA/K/ECO 182÷804 DIMENSIONS RTA/K/ECO L P H STD STD STD mm mm mm 182 202 242 262 302 363 393 453 524 604 804 5260 2200 2100 5480 2200 2340 5570 2200 2340 5570 2200 2340 5650 2200 2340 6170 2200 2340 6900 2200 2340 6900 2200 2340 8080 2200 2340 8470 2200 2510 11020 2200 2510 DIMENSIONAL CLEREANCE AREA RTA/K/ECO 182÷363 A mm 800 B mm 800 C mm 800 D (*) mm 1700 RTA/K/ECO 393÷804 A (**) mm 1000 B mm 1700 C mm 800 D mm 1700 NOTES (1) (2) (3) (4) (5) (*) (**) 4 Evaporator inlet air temperature 27 °C d.b. 19 °C w.b.; Ambient air temperature 35 °C; Excluded the power absorbed by centrifugal fans. Condensator inlet air temperature 20 °C; Ambient air temperature 7 °C d.b./6 °C w.b. Inlet air temperature 20 °C; Inlet water temperature 70 °C; Outlet water temperature 60 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Coil side. A SIDE: Electrical board side. 137 4 RTA/K/ECO/REC-FX 182÷804 ROOF TOP WITH SANDWICH PANELS WITH SCROLL COMPRESSORS, ECONOMIZER AND CROSS FLOW HEAT RECOVERY. FROM 58 kW TO 252 kW. UNIT DESCRIPTION The outdoor “Roof Top” self-contained air conditioning units of the RTA/K series, with R410A refrigerant, which can be connected to a duct network for air distribution, are ideal for the air conditioning of large surface areas for public use such as halls, shopping centres, cafeterias, restaurants and health centres, or for industrial environments such as food processing or preservation centres. Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in a cooling-only version and a version with reversible heat pump. They have a high degree of modularity and adaptability to every plant-engineering need since, in addition to the basic versions, it is also possible to add various solutions for the air treatment sections: mixing chamber, FREECOOLING, cross-flow heat recuperator, humidifier, hot air generator, etc. The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards. VERSIONS RTA/K/ECO/REC-FX Standard unit with economizer and cross flow heat recovery ECO/REC-FX - Cross flow heat recovery. Further to components of the basic section, includes: static recovery device made of aluminium with moisture drain pan, flat filters inspect able through hinged door and dampers + supply air damper + 2 free-cooling dampers). Also the adjustment of this section is included into the unit control. FEATURES ACCESSORIES • Structure of base perimeter made of steel sheet elements galvanised, passive treated and mould folded (3 mm thick). The frame is made of extruded aluminium alloy profiles connected by 3 way joints. The assembling of the base to the frame is of dual support and grants the walking on the base panels installation of which is effected without sticking out screws. 50 mm thick sandwich panels are made of prepainted steel sheet; water proofing is granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Condenser et evaporator with copper tube and aluminium finned coil. • Delivery and intake centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • R410A refrigerant. • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermo contacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit. • Microprocessor for the automatic control of the unit. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C FT Bag filter with F6-F7-F8 efficiency FT/R Rigid bag filter with F6-F7-F8 efficiency RF Cooling circuit shut off valves WS2 2-row water coil for heating with three way valve EH Electrical coil SQ Air quality sensor PF Differential pressostat filters control CP Potential free contacts RP Metallic guards for condenser COMPLEMENTARY SECTIONS UMI UMI/EN F/CD 138 ECO/REC-FX Section with preparation for Humidifier Section humidifier with electrodes immersed Condensation endothermic hot air generator with modulating gas burner Loose accessories: MN High and low gauges CS Shutter protection caps CR Remote display IS RS 485 serial interface AG Rubber shock absorbers TECHNICAL DATA R410A 182 202 242 262 302 Cooling capacity (1) kW Absorbed power (1),(2) kW Heating capacity (3) kW Heating Absorbed power (2),(3) kW Air flow m³/s static pressure Pa Air treatment section Fans n° Filters Air flow m³/s Air intake section static pressure Pa Fans n° Compressors n° Type Refrigerant circuits n° Condening Capacity steps n° section Fans n° Air flow m³/s Power supply V/Ph/Hz Max. running current A Electrical characteristics Inrush current A Heating capacity (4) kW Air pressure drops Pa Hot water coil Water flow (4) l/s Water pressure drops kPa Water connections ”G Power supply V/Ph/Hz Heating capacity kW Electric heating Max absorbed current A Steps n° Sound pressure STD (5) dB(A) Transport weight STD Kg 57.9 19.4 60.2 16.8 2.67 250 65.8 21.8 67.2 17.9 3.3 250 77.6 24 76.8 20.2 4.05 250 87.4 26.2 88.6 22.8 4.05 250 98.6 30.8 100.9 25.2 4.84 250 G4 2.67 100 1 2 G4 3.3 100 1 2 G4 4.05 100 1 2 G4 4.05 100 1 2 G4 4.84 100 1 2 1 2 2 6.9 1 2 2 7.1 1 2 2 6.9 1 2 2 6.7 1 2 2 6.7 50 173 85 30 2.03 45 1­”½ 53 175 100 31 2.39 47 1­”½ 63 186 125 31 2.99 48 1”­½ 67 199 125 31 2.99 48 1”­½ 76 243 150 31 3.58 49 1”­½ 15 22 2 58 1715 21 30 2 58 1800 27 39 2 58 1980 27 39 2 58 2090 27 39 2 58 2110 Cooling 363 393 453 524 604 804 113.1 128.9 37.8 40.4 114.7 132.8 32.2 34 5.49 6.32 250 250 1 G4 G4 5.49 6.32 100 100 1 1 3 3 Scroll 1 1 3 3 2 4 9.8 14 400 / 3 / 50 94 100 218 232 175 200 30 36 4.18 4.78 44 51 2” 2” 400 / 3 / 50 41 41 59 59 4 4 59 60 2370 2800 144.9 43.3 151.1 40 6.32 250 168 54.6 172.6 45.7 8.2 250 197.7 61.5 203.8 50.4 9.79 250 251.6 85.1 261.8 70.5 12.31 250 G4 6.32 100 1 3 G4 8.2 100 1 4 G4 9.79 100 1 4 G4 12.31 100 1 4 1 3 4 13.9 2 4 4 13.9 2 4 4 13.4 2 4 4 20 109 276 200 36 4.78 51 2” 133 265 250 35 5.97 53 2” 150 317 300 35 7.17 57 2”½ 173 347 350 35 8.36 55 2”1/2 41 59 4 60 2850 41 59 4 61 3370 48 69 4 61 3720 55 79 4 62 4720 RTA/K/ECO/REC-FX 182÷804 RTA/K/ECO/REC-FX 182÷804 DIMENSIONS RTA/K/ECO/REC-FX 182 202 242 262 302 363 393 453 524 604 804 L P H 6060 2200 2100 6060 2200 2340 6270 2200 2340 6270 2200 2340 6450 2200 2340 7050 2200 2340 7870 2200 2340 7870 2200 2340 9120 2200 2340 9380 2200 2510 11650 2200 2510 STD STD STD mm mm mm DIMENSIONAL CLEREANCE AREA RTA/K/ECO/REC-FX 182÷363 A mm 800 B mm 800 C mm 800 D (*) mm 1700 RTA/K/ECO/REC-FX 393÷804 A (**) mm 1000 B mm 1700 C mm 800 D mm 1700 NOTES (1) (2) (3) (4) (5) (*) (**) 4 Evaporator inlet air temperature 27 °C d.b. 19 °C w.b.; Ambient air temperature 35 °C; Excluded the power absorbed by centrifugal fans. Condensator inlet air temperature 20 °C; Ambient air temperature 7 °C d.b./6 °C w.b. Inlet air temperature 20 °C; Inlet water temperature 70 °C; Outlet water temperature 60 °C. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Coil side. A SIDE: Electrical board side. 139 4 MHA/K 15÷151 AIR COOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSORS. FROM 4 kW TO 45 kW. UNIT DESCRIPTION The condensing units and reversible condensing units of the MHA/K 15÷151 series, with R410A refrigerant, are intended to satisfy the needs of small and medium-sized domestic or industrial systems. With a peraluman structure, these outdoor units are combined with evaporators in split system air conditioning installations, allowing the rooms to be cooled and dehumidified or to be heated. They can also be used in combination with hydronic evaporator units, generally in air-conditioning applications They are equipped with Rotary/Scroll compressors and axial fans, and they enable immediate and efficient use thanks to particular technical and design adjustments. A wide range of accessories, all supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS MHA/K Standard unit 140 FEATURES ACCESSORIES • Structure with supporting frame, in peraluman and galvanized sheet. • Rotary/Scroll compressors with internal overheat protection and crankcase heater if needed. • Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors. • Condenser with copper tube and aluminium finned coil. • R410A refrigerant. • Electrical panel icludes: main switch with door lock device, fuses, compressor remote control switch. • Microprocessor control and regulation system. Loose accessories: CC Condensing control down to -20°C CV Moisture drain pan RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A MHA/K 15÷151 Heating Compressors Condenser Connections Electrical characteristics Sound pressure Transport weight 15 18 21 25 31 41 51 kW kW kW kW n° 4.5 1.4 4.8 1.5 1 5.6 1.8 5.9 1.9 1 6.8 2.1 7.3 2.3 1 8 2.5 8.4 2.6 1 9.2 2.9 9.7 3 1 13.2 4.1 13.7 4.2 1 n° m³/s Ø Ø V/Ph/Hz A A dB(A) Kg 1 0.86 15.9 9.5 1 0.86 15.9 9.5 1 0.81 15.9 9.5 1 0.81 15.9 9.5 1 0.76 15.9 9.5 10.8 3.7 11.3 3.8 1 Scroll 1 0.76 15.9 9.5 7 37 49 81 9 43 49 83 11 62 49 87 15 79 51 90 18 86 52 92 2 1.61 19 12.7 400 / 3+N / 50 7 58 52 109 61 71 81 91 101 131 151 kW kW kW kW n° 15.8 5.1 16.8 5.3 1 19.1 6.2 19.9 6.4 1 21.2 7.1 22 7.3 1 30.9 9.2 33.2 9.8 1 36.6 11.5 40.9 11.9 1 45.9 14.2 51.9 15.2 1 n° m³/s Ø Ø V/Ph/Hz A A dB(A) Kg 2 1.53 19 12.7 2 1.53 22 12.7 2 1.53 22 12.7 2 4.61 22 12.7 2 4.61 22 12.7 2 4.61 22 15.9 10 61 52 111 10 58 52 113 12 74 52 115 26.4 8.6 27.4 8.8 1 Scroll 1 2.25 22 12.7 400 / 3+N / 50 23 142 53 218 29 147 54 232 30 142 55 252 39 167 56 266 MHA/K 15÷151 Cooling Heating Compressors Condenser Connections Electrical characteristics Sound pressure Transport weight Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Fans Air flow Suction line OUT Power supply Max. running current Inrush current STD (3) STD Rotary 11 62 49 83 230 / 1 / 50 MHA/K 15÷151 Cooling Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Fans Air flow Suction line OUT Power supply Max. running current Inrush current STD (3) STD DIMENSIONS MHA/K L P H STD STD STD mm mm mm 15 18 21 25 31 41 51 61 71 81 91 101 131 151 870 320 1100 870 320 1100 870 320 1100 870 320 1100 870 320 1100 870 320 1100 1160 500 1270 1160 500 1270 1160 500 1270 1160 500 1270 1850 1000 1300 1850 1000 1300 1850 1000 1300 1850 1000 1300 DIMENSIONAL 15 ÷ 41 51 ÷ 81 NOTES CLEREANCE AREA 91 ÷ 151 (1) MHA/K 15 ÷ 41 A mm B mm C mm D (*) mm 200 200 800 800 MHA/K 51 ÷ 81 A mm B mm C mm D (*) mm 200 200 800 800 MHA/K 91 ÷ 151 A (**) mm B mm C mm D mm 800 800 500 800 (2) (3) (*) (**) 4 Average evaporating temperatur 5 °C, ambient air temperature 35 °C. Average condensing temperatur 40 °C, ambient air temperature 7 °C d.b. / 6 °C w.b. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. D SIDE: Coil side. A SIDE: Electrical board side. 141 4 MHA/K 182÷604 AIR COOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND SCROLL COMPRESSORS. FROM 50 kW TO 188 kW. UNIT DESCRIPTION The condensing units and reversible condensing units of the MHA/K 182÷604 series, with R410A refrigerant, are intended to satisfy the needs of medium/large-sized domestic or industrial systems. These outdoor units are combined with evaporators in split system air conditioning installations, allowing the rooms to be cooled and dehumidified or to be heated. They can also be used in combination with hydronic evaporator units in both air-conditioning and industrial process cooling applications They are equipped with Scroll compressors and axial fans, and they enable immediate and efficient use thanks to particular technical and design adjustments. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS MHA/K Standard unit FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Axial fans directly coupled to an electric motor with external rotor. • Condenser with copper tube and aluminium finned coil. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement CT Condensing control down to 0 °C CC Condensing control down to -20°C RF Cooling circuit shut off valves RL Liquid receiver VS Solenoid valve BP HGBP by-pass valve FF Dryer filter + sightglass CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers 142 TECHNICAL DATA R410A MHA/K 182÷604 202 242 262 302 363 393 453 524 604 kW kW kW kW n° 50.6 17.4 55.5 14.7 2 58.6 19.7 63.5 16 2 66.9 22.5 73.6 19.1 2 77.2 25.8 83.9 21.7 2 88.4 29.5 94.5 24.4 2 102 34.2 109 27.9 3 117 39.2 125 32.7 3 134 45.6 142 36.6 3 156 53.2 162 41.7 4 188 63.2 193 49.5 4 n° n° n° m³/s dB(A) dB(A) Ø mm Ø mm V/Ph/Hz A A Kg 1 1 1 1 1 1 2 2 7.1 60 58 1x35 1x22 1 3 2 9.7 61 59 1x42 1x28 2 9.7 61 59 1x42 1x28 2 11.4 61 59 2x35 2x22 3 15 61 59 2x35 2x22 56 188 625 85 218 800 98 265 830 111 243 980 132 299 1090 Cooling Scroll 1 4.8 56 54 1x35 1x22 1 4.7 56 54 1x35 1x22 1 2 2 7.1 60 58 1x35 1x22 40 163 550 43 165 575 52 175 615 2 2 7.3 7.1 60 60 58 58 1x35 1x42 1x22 1x28 400 / 3 / 50 65 75 232 199 670 770 2 4 MHA/K 182÷604 Cooling capacity (1) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Fans STD version Air flow and with SL Sound pressure (3) accessory SL sound pressure (3) Suction line Connections OUT Power supply Electrical Max. running current characteristics Inrush current Transport weight STD 182 DIMENSIONS MHA/K L P H STD STD STD mm mm mm 182 202 242 262 302 363 393 453 524 604 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 1920 2350 1100 2220 2350 1100 2220 2350 1100 2220 2350 1100 2220 3550 1100 2220 3550 1100 2220 DIMENSIONAL NOTES CLEREANCE AREA (1) MHA/K 182÷604 A B C D (*) mm mm mm mm 300 1800 800 800 (2) (3) (*) 4 Average evaporating temperatur 5 °C, ambient air temperature 35 °C. Average condensing temperatur 40 °C, ambient air temperature 7 °C d.b. / 6 °C w.b. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. C SIDE: Electrical board side. 143 4 MRA/K 15÷131 AIR COOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH RADIAL FANS AND ROTARY/SCROLL COMPRESSORS. FROM 4 kW TO 37 kW. UNIT DESCRIPTION The indoor condensing units and reversible condensing units of the MRA/K 15÷131 series, with R410A refrigerant, are intended to satisfy the needs of small and medium-sized domestic or industrial systems with particular difficulty in positioning units outside the building. With a prepainted plate structure, these units are combined with evaporators in split system air conditioning installations, allowing the rooms to be cooled and dehumidified or to be heated. They can also be used in combination with hydronic evaporator units, generally in air-conditioning applications They are equipped with Scroll compressors and centrifugal fans, with appreciable useful head, and they enable immediate and efficient use thanks to particular technical and design adjustments. A wide range of accessories, all supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS MRA/K Standard unit 144 FEATURES ACCESSORIES • Self-supporting prepainted steel frame. • Rotary/Scroll compressors with internal overheat protection and crankcase heater if needed. • Double inlet centrifugal type fan statically and dynamically balanced directly driven by a electric motor (15÷81) or belt driven connected to a three-phase electric motor (91÷131). • Condenser in copper tubes and aluminium finned coil. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuse and overload protection for compressors. • Microprocessor control and regulation system. Loose accessories: CC Condensing control down to -20°C RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A MRA/K 15÷131 Heating Compressors Condenser Connections Electrical characteristics Sound pressure 15 18 21 25 31 41 51 kW kW kW kW n° 4.5 1.5 4.8 1.6 1 5.6 1.9 5.9 2 1 6.8 2.2 7.3 2.4 1 8 2.6 8.4 2.7 1 9.2 3 9.7 3.1 1 13.2 4.9 13.7 5 1 n° m³/s Pa Ø Ø V/Ph/Hz A A dB(A) Kg 1 0.94 90 15.9 9.5 1 0.94 90 15.9 9.5 1 0.94 80 15.9 9.5 1 0.94 80 15.9 9.5 1 0.9 80 15.9 9.5 10.8 3.8 11.3 3.9 1 Scroll 1 0.9 80 15.9 9.5 10 40 49 120 12 46 49 121 14 65 49 126 17 82 51 131 21 89 52 133 MRA/K 15÷131 Cooling Heating Compressors Condenser Connections Electrical characteristics Sound pressure Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Fans Air flow static pressure Suction line OUT Power supply Max. running current Inrush current STD (3) STD Rotary 13 65 49 123 230/1/50 1 1.92 115 19 12.7 400/3+N/50 11 61 52 190 61 71 81 91 101 131 kW kW kW kW n° 15.8 5.9 16.8 6.1 1 19.1 7 19.9 7.2 1 21.2 7.9 22 8.1 1 26.4 10.3 27.4 10.5 1 30.9 10.4 33.2 11 1 36.6 13.5 40.9 13.9 1 n° m³/s Pa Ø Ø V/Ph/Hz A A dB(A) Kg 1 1.89 115 19 12.7 1 1.89 115 22 12.7 1 1.89 115 22 12.7 1 3.17 150 22 12.7 1 3.17 150 22 12.7 1 3.56 160 22 12.7 14 64 52 200 14 61 53 202 15 77 62 204 27 146 62 313 33 151 62 319 36 148 63 334 Scroll 400/3+N/50 MRA/K 15÷131 Cooling Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Quantity Type Fans Air flow static pressure Suction line OUT Power supply Max. running current Inrush current STD (3) STD DIMENSIONS MRA/K L P H STD STD STD mm mm mm 15 18 21 25 31 41 51 61 71 81 91 101 131 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 550 1425 900 690 1725 900 690 1725 900 690 1725 900 690 1725 1500 800 1425 1500 800 1425 1500 800 1425 DIMENSIONAL 15 ÷ 41 51 ÷ 81 NOTES CLEREANCE AREA 91 ÷ 131 (1) MRA/K 15÷41 A (*) mm B mm C mm D mm 800 800 100 800 MRA/K 51÷81 A (*) mm B mm C mm D mm 800 800 1000 100 MRA/K 91÷131 A mm B mm C mm D (**) mm 100 1200 800 800 (2) (3) (*) (**) Average evaporating temperatur 5 °C, ambient air temperature 35 °C. Average condensing temperatur 40 °C, ambient air temperature 7 °C d.b. / 6 °C w.b. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. D SIDE: Electrical board side. 4 145 4 MRA/K 182÷604 AIR COOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH RADIAL FANS AND SCROLL COMPRESSORS. FROM 50 kW TO 188 kW. UNIT DESCRIPTION The indoor condensing units and reversible condensing units of the MRA/K 182÷604 series, with R410A refrigerant, are intended to satisfy the needs of medium/large-sized domestic or industrial systems with particular difficulty in positioning units outside the building. These units are combined with evaporators in split system air conditioning installations, allowing the rooms to be cooled and dehumidified or to be heated. They can also be used in combination with hydronic evaporator units in both air-conditioning and industrial process cooling applications They are equipped with Scroll compressors and centrifugal fans and they enable immediate and efficient use thanks to particular technical and design adjustments. A wide range of accessories, factory-assembled or supplied separately, complete the outstanding versatility and functionality of the series. VERSIONS MRA/K Standard unit 146 FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater if needed. • Centrifugal type fans coupled to 3-phase motors by V belt and variable pulley. • Condenser with copper tube and aluminium finned coil. • R410A refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement CC Condensing control down to -20°C RF Cooling circuit shut off valves RL Liquid receiver VS Solenoid valve BP HGBP by-pass valve FF Dryer filter + sightglass CP Potential free contacts Loose accessories: MN High and low gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers TECHNICAL DATA R410A MRA/K 182÷604 202 242 262 302 363 393 453 524 604 kW kW kW kW n° 50.6 18.3 55.5 15.6 2 58.6 21.4 63.5 17.7 2 66.9 24.9 73.6 21.5 2 77.2 28.2 83.9 24.1 2 88.4 31.9 94.5 26.8 2 102 36.6 109 30.3 3 117 43.2 125 36.7 3 134 49.6 142 40.6 3 156 58.2 162 46.7 4 188 69.2 193 55.5 4 n° n° n° m³/s Pa dB(A) dB(A) Ø mm Ø mm V/Ph/Hz A A Kg 1 1 1 1 1 1 2 2 7.1 120 66 63 1x35 1x22 1 3 2 8.9 135 67 64 1x42 1x28 2 8.9 135 67 64 1x42 1x28 3 11.4 190 67 64 2x35 2x22 3 13.9 105 67 64 2x35 2x22 61 193 680 94 227 865 107 275 895 122 255 1080 146 313 1185 Cooling Scroll 1 3.3 165 65 62 1x35 1x22 1 4.2 147 65 62 1x35 1x22 1 2 2 7.1 120 66 63 1x35 1x22 43 166 595 48 169 600 57 180 670 2 2 7.3 7.1 105 115 66 67 63 64 1x35 1x42 1x22 1x28 400 / 3 / 50 70 80 237 204 725 825 2 4 MRA/K 182÷604 Cooling capacity (1) Absorbed power (1) Heating capacity (2) Heating Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Fans Air flow STD version and with SL static pressure accessory Sound pressure (3) SL sound pressure (3) Suction line Connections OUT Power supply Electrical Max. running current characteristics Inrush current Transport weight STD 182 DIMENSIONS MRA/K L P H STD STD STD mm mm mm 182 202 242 262 302 363 393 453 524 604 2350 1100 1705 2350 1100 1705 2350 1100 1705 2350 1100 1705 2350 1100 2005 2350 1100 2005 2350 1100 2005 2350 1100 2005 3550 1100 2005 3550 1100 2005 DIMENSIONAL NOTES CLEREANCE AREA (1) MRA/K 182÷604 A (*) B C D mm mm mm mm 800 1800 300 800 (2) (3) (*) 4 Average evaporating temperatur 5 °C, ambient air temperature 35 °C. Average condensing temperatur 40 °C, ambient air temperature 7 °C d.b. / 6 °C w.b. Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744. A SIDE: Electrical board side. 147 5 INDEX Hydronic air-handled units and supervision systems. INDEX FVW 12÷74 marvin FVW 12÷74 floyd FVW 12÷74 elmer FVW 12÷74 FIW 12÷74 HWW/V 22÷83 eurìce TCW 42÷104 UTW 63÷544 DBM-DBA / DRM-DRA CLIMAFRIEND Page 150 - 151 152 - 153 154 - 155 156 - 157 158 - 159 160 - 161 162 - 163 164 - 165 166 167 5 149 5 FVW 12÷74 marvin FAN COIL UNIT WITH CENTRIFUGAL FANS FOR FLOOR OR CEILING INSTALLATION. FROM 0,9 kW TO 7,3 kW. UNIT DESCRIPTION MARVIN features an exclusive design which is the result of the experience of architects and engineers who have combined in a single unit aesthetic beauty along with advanced functional and technical solutions for the air conditioning of any room. Inserted in a system equipped with a water chiller, MARVINn generates cool air silently and immediately. During the winter, if used in conjunction with a heating system with a boiler or heat pump, it provides warm air, making it possible to meet home or business heating needs. A filter that absorbs and holds suspended powders maintains suitable air quality. Since it can be easily removed, constant cleaning cycles can be performed, which is especially important in busy rooms to ensure suitable standards of hygiene. All installation needs are considered in the many standard features of MARVIN. It can be installed horizontally or vertically, with front or lower intake. There is also a series of accessories, also for a 4-pipe system, that includes a control panel that is installed on-board the machine or in the room. It can also be used in conjunction with the innovative CLIMAFRIEND control and supervision system, to intuitively and efficiently programme and maintain an optimal level of comfort. VERSIONS FVW/VP Vertical unit with cabinet bottom inlet and vertical delivery FVW/VH Vertical unit with cabinet front inlet and vertical delivery FVW/VE Horizontal unit with cabinet rear inlet and horizontal delivery FVW/VO Horizontal unit with cabinet bottom inlet and horizontal delivery FEATURES • Structure made of galvanized sheet protected by a prepainted sheet covering cabinet and ABS details, complete with heat/ sound insulation, regenerating filter, heat-resistant ABS polymer grills adjustable in 4 different directions and natural discharge condensation tray. • Centrifugal fan type directly coupled to a 6-speed singlephase electric motor, with 3 speeds connected in the standard configuration. • Heat exchanger coil with copper pipes and aluminium fins with airvent on the distributors. ACCESSORIES Loose accessories: Z Pair of feet C Auxiliary tray WS Exchanger for 4 tubes systems EH Electrical heating element RP Rear panel TP Rear closing S Manual dampers SG Manual dampers with grill SM ON/OFF motorized dampers SMG ON/OFF motorized dampers with grill 150 RM SF VB VR DBM DRM DBA DRA DRE TA TMB TME V2 V4 MP Wall connection for dampers Supply frame Built-in fan speed control Fan speed controls Built-in control panel Electronic control panels Built-in automatic control panel Remote automatic control panel EASY electronic control panel Remote room thermostat Minimum temperature thermostat for VB and VR Minimum temperature electronic thermostat for DBM, DRM, DBA and DRA 3-way on/off valve for system with 2 pipes 3-ways on/off valves for 4 pipes system Micro pump for moisture TECHNICAL DATA H2O FVW 12÷74 marvin Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg FVW 12÷74 marvin Total Cooling capacity (1) Sensible Cooling capacity (1) Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg 12 13 14 22 23 24 32 33 34 42 43 0.95 0.9 163 2.1 2.61 224 1.6 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.31 1.09 225 5.4 3.2 275 4.1 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.49 1.26 253 1 3.45 297 0.8 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.29 1.15 222 4.2 3.66 315 3.2 2.16 186 6.7 340 260 170 54 48 36 44 38 26 1.77 1.45 304 10.7 4.19 360 8.1 2.16 186 6.7 340 260 170 54 48 36 44 38 26 2.02 1.69 347 11.4 5.06 435 8.6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.47 1.96 425 8 5.7 490 6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.77 2.16 476 5.2 6.35 546 3.9 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.51 2.04 432 2.4 6.44 554 15.1 3.75 322 25.7 540 420 280 54 47 37 44 37 27 3.11 2.42 535 14.2 7.03 605 10.7 3.75 322 25.7 540 420 280 54 47 37 44 37 27 0.02 1/2” 16 0.02 1/2” 16 0.02 1/2” 16 0.04 1/2” 19 0.04 1/2” 19 2.05 1.68 353 2.1 4.53 390 1.6 2.16 186 6.7 340 260 170 54 48 36 44 38 26 230 / 1 / 50 0.04 1/2” 19 0.05 1/2” 24 0.05 1/2” 24 0.05 1/2” 24 0.07 1/2” 28 0.07 1/2” 28 44 52 53 54 3.54 2.71 609 9.1 7.75 666 6.8 3.75 322 25.7 540 420 280 54 47 37 44 37 27 2.9 2.48 499 4.8 7.9 679 3.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.04 3.12 695 26.2 9.01 775 19.7 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.58 3.47 788 16.7 9.93 854 12.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 0.07 1/2” 28 0.08 1/2” 33 0.08 1/2” 33 0.08 1/2” 33 62 63 3.86 5.09 3.18 3.86 664 875 10.9 8 10.54 11.69 906 1005 8.1 5.9 6.01 6.01 517 517 13.1 13.1 910 910 730 730 510 510 58 58 53 53 44 44 48 48 43 43 34 34 230 / 1 / 50 0.16 0.16 1/2” 1/2” 43 43 64 72 73 74 5.96 4.63 1025 5.2 13 1118 3.8 6.01 517 13.1 910 730 510 58 53 44 48 43 34 5.16 4.18 888 21.6 13.16 1132 16.3 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 6.45 5.07 1109 15.8 14.59 1255 11.9 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 7.26 5.57 1249 10.2 16.19 1392 7.6 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 0.16 1/2” 43 0.2 1/2” 54 0.2 1/2” 54 0.2 1/2” 54 FVW 12÷74 marvin Total Cooling capacity (1) Sensible Cooling capacity (1) DIMENSIONS FVW L H P D (*) STD STD STD STD mm mm mm mm 12 13 14 22 23 24 32 33 34 42 43 44 52 53 54 62 63 64 72 73 74 690 500 210 90 690 500 210 90 690 500 210 90 820 500 210 90 820 500 210 90 820 500 210 90 1080 500 210 90 1080 500 210 90 1080 500 210 90 1210 500 210 90 1210 500 210 90 1210 500 210 90 1470 500 210 90 1470 500 210 90 1470 500 210 90 1470 570 275 90 1470 570 275 90 1470 570 275 90 1730 570 275 90 1730 570 275 90 1730 570 275 90 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (*) D: Feet height. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 151 5 FVW 12÷74 floyd FAN COIL UNIT WITH CENTRIFUGAL FANS FOR FLOOR OR CEILING INSTALLATION. FROM 0,9 kW TO 7,3 kW. UNIT DESCRIPTION The FLOYD fan coil unit features a refined, exclusive design that lets you install an efficient air conditioning unit in any room, with no aesthetic compromises and without compromising the functionality and harmony of the spaces of the home or business. Inserted in a system equipped with a water chiller, FLOYD generates cool air silently and immediately. During the winter, if used in conjunction with a heating system with a boiler or heat pump, it provides warm air, making it possible to meet home or business heating needs. A filter that absorbs and holds suspended powders maintains suitable air quality. Since it can be easily removed, constant cleaning cycles can be performed, which is especially important in busy rooms to ensure suitable standards of hygiene. All installation needs are considered in the many standard features of FLOYD. It can be installed horizontally or vertically, with front or lower intake. There is also a series of accessories, also for a 4-pipe system, that includes a control panel that is installed on-board the machine or in the room. It can also be used in conjunction with the innovative CLIMAFRIEND control and supervision system, to intuitively and efficiently programme and maintain an optimal level of comfort. VERSIONS FVW/VP Vertical unit with cabinet bottom inlet and vertical delivery FVW/VH Vertical unit with cabinet front inlet and vertical delivery FVW/VE Horizontal unit with cabinet rear inlet and horizontal delivery FVW/VO Horizontal unit with cabinet bottom inlet and horizontal delivery FEATURES • Structure made of galvanized sheet protected by a prepainted sheet covering cabinet and ABS details, complete with heat/ sound insulation, regenerating filter, heat-resistant ABS polymer grills adjustable in 4 different directions and natural discharge condensation tray. • Centrifugal fan type directly coupled to a 6-speed singlephase electric motor, with 3 speeds connected in the standard configuration. • Heat exchanger coil with copper pipes and aluminium fins with airvent on the distributors. ACCESSORIES Loose accessories: Z Pair of feet C Auxiliary tray WS Exchanger for 4 tubes systems EH Electrical heating element RP Rear panel TP Rear closing S Manual dampers SG Manual dampers with grill SM ON/OFF motorized dampers SMG ON/OFF motorized dampers with grill 152 RM SF VB VR DBM DRM DBA DRA DBE DRE TA TMB TME V2 V4 MP Wall connection for dampers Supply frame Built-in fan speed control Fan speed controls Built-in control panel Electronic control panels Built-in automatic control panel Remote automatic control panel EASY Built-in electronic control panel EASY electronic control panel Remote room thermostat Minimum temperature thermostat for VB and VR Minimum temperature electronic thermostat for DBM, DRM, DBA and DRA 3-way on/off valve for system with 2 pipes 3-ways on/off valves for 4 pipes system Micro pump for moisture TECHNICAL DATA H2O FVW 12÷74 floyd Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg FVW 12÷74 floyd Total Cooling capacity (1) Sensible Cooling capacity (1) Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg 12 13 14 22 23 24 32 33 34 42 43 0,95 0,90 163 2,1 2,61 224 1,6 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,31 1,09 225 5,4 3,20 275 4,1 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,49 1,26 253 1,0 3,45 297 0,8 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,29 1,15 222 4,2 3,66 315 3,2 2,16 186 6,7 340 260 170 54 48 36 44 38 26 1,77 1,45 304 10,7 4,19 360 8,1 2,16 186 6,7 340 260 170 54 48 36 44 38 26 2.02 1.69 347 11.4 5.06 435 8.6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.47 1.96 425 8 5.7 490 6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.77 2.16 476 5.2 6.35 546 3.9 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.51 2.04 432 2.4 6.44 554 15.1 3.75 322 25.7 540 420 280 54 47 37 44 37 27 3.11 2.42 535 14.2 7.03 605 10.7 3.75 322 25.7 540 420 280 54 47 37 44 37 27 0,02 1/2” 16 0,02 1/2” 16 0,02 1/2” 16 0,04 1/2” 19 0,04 1/2” 19 2,05 1,68 353 2,1 4,53 390 1,6 2,16 186 6,7 340 260 170 54 48 36 44 38 26 230 / 1 / 50 0,04 1/2” 19 0.05 1/2” 24 0.05 1/2” 24 0.05 1/2” 24 0.07 1/2” 28 0.07 1/2” 28 44 52 53 54 3.54 2.71 609 9.1 7.75 666 6.8 3.75 322 25.7 540 420 280 54 47 37 44 37 27 2.9 2.48 499 4.8 7.9 679 3.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.04 3.12 695 26.2 9.01 775 19.7 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.58 3.47 788 16.7 9.93 854 12.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 0.07 1/2” 28 0.08 1/2” 33 0.08 1/2” 33 0.08 1/2” 33 62 63 3.86 5.09 3.18 3.86 664 875 10.9 8 10.54 11.69 906 1005 8.1 5.9 6.01 6.01 517 517 13.1 13.1 910 910 730 730 510 510 58 58 53 53 44 44 48 48 43 43 34 34 230 / 1 / 50 0.16 0.16 1/2” 1/2” 43 43 64 72 73 74 5.96 4.63 1025 5.2 13 1118 3.8 6.01 517 13.1 910 730 510 58 53 44 48 43 34 5.16 4.18 888 21.6 13.16 1132 16.3 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 6.45 5.07 1109 15.8 14.59 1255 11.9 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 7.26 5.57 1249 10.2 16.19 1392 7.6 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 0.16 1/2” 43 0.2 1/2” 54 0.2 1/2” 54 0.2 1/2” 54 FVW 12÷74 floyd Total Cooling capacity (1) Sensible Cooling capacity (1) DIMENSIONS FVW L H P D (*) STD STD STD STD mm mm mm mm 12 13 14 22 23 24 32 33 34 42 43 44 52 53 54 62 63 64 72 73 74 650 500 210 90 650 500 210 90 650 500 210 90 780 500 210 90 780 500 210 90 780 500 210 90 1046 500 210 90 1046 500 210 90 1046 500 210 90 1170 500 210 90 1170 500 210 90 1170 500 210 90 1430 500 210 90 1430 500 210 90 1430 500 210 90 1430 570 275 90 1430 570 275 90 1430 570 275 90 1690 570 275 90 1690 570 275 90 1690 570 275 90 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (*) D: Feet height. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 153 5 FVW 12÷74 elmer FAN COIL UNIT WITH CENTRIFUGAL FANS FOR FLOOR OR CEILING INSTALLATION. FROM 0,9 kW TO 7,3 kW. UNIT DESCRIPTION Featuring innovative technical solutions and design, which transform the usual fan coil unit into a silent and efficient part of the home or business setting. Inserted in a system equipped with a water chiller, ELMER generates cool air silently and immediately. During the winter, if used in conjunction with a heating system with a boiler or heat pump, it provides warm air, making it possible to meet home or business heating needs. A filter that absorbs and holds suspended powders maintains suitable air quality. Since it can be easily removed, constant cleaning cycles can be performed, which is especially important in busy rooms to ensure suitable standards of hygiene. All installation needs are considered in the many standard features of ELMER. It can be installed horizontally or vertically, with front or lower intake. There is also a series of accessories, also for a 4-pipe system, that includes a control panel that is installed on-board the machine or in the room. It can also be used in conjunction with the innovative CLIMAFRIEND control and supervision system, to intuitively and efficiently programme and maintain an optimal level of comfort. VERSIONS FVW/VP Vertical unit with cabinet bottom inlet and vertical delivery FVW/VP Vertical unit with cabinet front inlet and vertical delivery FVW/VE Horizontal unit with cabinet rear inlet and horizontal delivery FVW/VO Horizontal unit with cabinet bottom inlet and horizontal delivery FEATURES • Structure made of galvanized sheet protected by a prepainted sheet covering cabinet and ABS details, complete with heat/ sound insulation, regenerating filter, heat-resistant ABS polymer grills adjustable in 4 different directions and natural discharge condensation tray. • Centrifugal fan type directly coupled to a 6-speed singlephase electric motor, with 3 speeds connected in the standard configuration. • Heat exchanger coil with copper pipes and aluminium fins with airvent on the distributors. ACCESSORIES Loose accessories: Z Pair of feet C Auxiliary tray WS Exchanger for 4 tubes systems EH Electrical heating element RP Rear panel TP Rear closing S Manual dampers SG Manual dampers with grill SM ON/OFF motorized dampers SMG ON/OFF motorized dampers with grill 154 RM SF VB VR DBM DRM DBA DRA DBE DRE TA TMB TME V2 V4 MP Wall connection for dampers Supply frame Built-in fan speed control Fan speed controls Built-in control panel Electronic control panels Built-in automatic control panel Remote automatic control panel EASY Built-in electronic control panel EASY electronic control panel Remote room thermostat Minimum temperature thermostat for VB and VR Minimum temperature electronic thermostat for DBM, DRM, DBA and DRA 3-way on/off valve for system with 2 pipes 3-ways on/off valves for 4 pipes system Micro pump for moisture TECHNICAL DATA H2O FVW 12÷74 elmer Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg FVW 12÷74 elmer Total Cooling capacity (1) Sensible Cooling capacity (1) Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg 12 13 14 22 23 24 32 33 34 42 43 0,95 0,90 163 2,1 2,61 224 1,6 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,31 1,09 225 5,4 3,20 275 4,1 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,49 1,26 253 1,0 3,45 297 0,8 1,50 129 2,9 240 190 140 51 44 36 41 34 26 1,29 1,15 222 4,2 3,66 315 3,2 2,16 186 6,7 340 260 170 54 48 36 44 38 26 1,77 1,45 304 10,7 4,19 360 8,1 2,16 186 6,7 340 260 170 54 48 36 44 38 26 2.02 1.69 347 11.4 5.06 435 8.6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.47 1.96 425 8 5.7 490 6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.77 2.16 476 5.2 6.35 546 3.9 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.51 2.04 432 2.4 6.44 554 15.1 3.75 322 25.7 540 420 280 54 47 37 44 37 27 3.11 2.42 535 14.2 7.03 605 10.7 3.75 322 25.7 540 420 280 54 47 37 44 37 27 0,02 1/2” 16 0,02 1/2” 16 0,02 1/2” 16 0,04 1/2” 19 0,04 1/2” 19 2,05 1,68 353 2,1 4,53 390 1,6 2,16 186 6,7 340 260 170 54 48 36 44 38 26 230 / 1 / 50 0,04 1/2” 19 0.05 1/2” 24 0.05 1/2” 24 0.05 1/2” 24 0.07 1/2” 28 0.07 1/2” 28 44 52 53 54 3.54 2.71 609 9.1 7.75 666 6.8 3.75 322 25.7 540 420 280 54 47 37 44 37 27 2.9 2.48 499 4.8 7.9 679 3.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.04 3.12 695 26.2 9.01 775 19.7 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.58 3.47 788 16.7 9.93 854 12.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 0.07 1/2” 28 0.08 1/2” 33 0.08 1/2” 33 0.08 1/2” 33 62 63 3.86 5.09 3.18 3.86 664 875 10.9 8 10.54 11.69 906 1005 8.1 5.9 6.01 6.01 517 517 13.1 13.1 910 910 730 730 510 510 58 58 53 53 44 44 48 48 43 43 34 34 230 / 1 / 50 0.16 0.16 1/2” 1/2” 43 43 64 72 73 74 5.96 4.63 1025 5.2 13 1118 3.8 6.01 517 13.1 910 730 510 58 53 44 48 43 34 5.16 4.18 888 21.6 13.16 1132 16.3 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 6.45 5.07 1109 15.8 14.59 1255 11.9 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 7.26 5.57 1249 10.2 16.19 1392 7.6 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 0.16 1/2” 43 0.2 1/2” 54 0.2 1/2” 54 0.2 1/2” 54 FVW 12÷74 elmer Total Cooling capacity (1) Sensible Cooling capacity (1) DIMENSIONS FVW L H P D (*) STD STD STD STD mm mm mm mm 12 13 14 22 23 24 32 33 34 42 43 44 52 53 54 62 63 64 72 73 74 650 500 210 90 650 500 210 90 650 500 210 90 780 500 210 90 780 500 210 90 780 500 210 90 1040 500 210 90 1040 500 210 90 1040 500 210 90 1170 500 210 90 1170 500 210 90 1170 500 210 90 1430 500 210 90 1430 500 210 90 1430 500 210 90 1430 570 275 90 1430 570 275 90 1430 570 275 90 1690 570 275 90 1690 570 275 90 1690 570 275 90 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (*) D: Feet height. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 155 5 FVW 12÷74 FAN COIL UNIT WITH CENTRIFUGAL FANS FOR FLOOR INSTALLATION. FROM 0,9 kW TO 7,3 kW. UNIT DESCRIPTION The water terminals of the FVW series are designed for vertical floormounted installation, with or without feet, in domestic environments or the services sector including offices, hotels, restaurants, gyms and shops. If connected to a system equipped with a water cooler, the FVW fan convector generates cool air silently and immediately. Otherwise, during the winter, if combined with a heating system with boiler or heat pump, it delivers warm air to satisfy the heating needs of households and the service industry alike. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. These units can be combined with the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently. VERSIONS FVW/VF Vertical unit with cabinet bottom inlet and oblique delivery FVW/VW Vertical unit with cabinet front inlet and oblique delivery 156 FEATURES ACCESSORIES • Structure made of galvanized sheet protected by a prepainted sheet covering cabinet and ABS details, complete with heat/ sound insulation, regenerating filter, heat-resistant ABS polymer grills adjustable in 4 different directions and natural discharge condensation tray. • Centrifugal fan type directly coupled to a 6-speed singlephase electric motor, with 3 speeds connected in the standard configuration. • Heat exchanger coil with copper pipes and aluminium fins with airvent on the distributors. Loose accessories: Z Pair of feet C Auxiliary tray WS Exchanger for 4 tubes systems EH Electrical heating element RP Rear panel TP Rear closing S Manual dampers SG Manual dampers with grill SM ON/OFF motorized dampers SMG ON/OFF motorized dampers with grill RM Wall connection for dampers SF Supply frame VB Built-in fan speed control VR Fan speed controls DBM Built-in control panel DRM Electronic control panels DBA Built-in automatic control panel DRA Remote automatic control panel DRE EASY electronic control panel TA Remote room thermostat TMB Minimum temperature thermostat for VB and VR TME Minimum temperature electronic thermostat for DBM, DRM, DBA and DRA V2 3-way on/off valve for system with 2 pipes V4 3-ways on/off valves for 4 pipes system MP Micro pump for moisture TECHNICAL DATA H2O FVW 12÷74 Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg FVW 12÷74 Total Cooling capacity (1) Sensible Cooling capacity (1) Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg 12 13 14 22 23 24 32 33 34 42 43 0.95 0.9 163 2.1 2.61 224 1.6 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.31 1.09 225 5.4 3.2 275 4.1 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.49 1.26 253 1 3.45 297 0.8 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.29 1.15 222 4.2 3.66 315 3.2 2.16 186 6.7 340 260 170 54 48 36 44 38 26 1.77 1.45 304 10.7 4.19 360 8.1 2.16 186 6.7 340 260 170 54 48 36 44 38 26 2.02 1.69 347 11.4 5.06 435 8.6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.47 1.96 425 8 5.7 490 6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.77 2.16 476 5.2 6.35 546 3.9 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.51 2.04 432 2.4 6.44 554 15.1 3.75 322 25.7 540 420 280 54 47 37 44 37 27 3.11 2.42 535 14.2 7.03 605 10.7 3.75 322 25.7 540 420 280 54 47 37 44 37 27 0.02 1/2” 16 0.02 1/2” 16 0.02 1/2” 16 0.04 1/2” 19 0.04 1/2” 19 2.05 1.68 353 2.1 4.53 390 1.6 2.16 186 6.7 340 260 170 54 48 36 44 38 26 230/ 1 / 50 0.04 1/2” 19 0.05 1/2” 24 0.05 1/2” 24 0.05 1/2” 24 0.07 1/2” 28 0.07 1/2” 28 44 52 53 54 3.54 2.71 609 9.1 7.75 666 6.8 3.75 322 25.7 540 420 280 54 47 37 44 37 27 2.9 2.48 499 4.8 7.9 679 3.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.04 3.12 695 26.2 9.01 775 19.7 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.58 3.47 788 16.7 9.93 854 12.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 0.07 1/2” 28 0.08 1/2” 33 0.08 1/2” 33 0.08 1/2” 33 62 63 3.86 5.09 3.18 3.86 664 875 10.9 8 10.54 11.69 906 1005 8.1 5.9 6.01 6.01 517 517 13.1 13.1 910 910 730 730 510 510 58 58 53 53 44 44 48 48 43 43 34 34 230/ 1 / 50 0.16 0.16 1/2” 1/2” 43 43 64 72 73 74 5.96 4.63 1025 5.2 13 1118 3.8 6.01 517 13.1 910 730 510 58 53 44 48 43 34 5.16 4.18 888 21.6 13.16 1132 16.3 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 6.45 5.07 1109 15.8 14.59 1255 11.9 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 7.26 5.57 1249 10.2 16.19 1392 7.6 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 0.16 1/2” 43 0.2 1/2” 54 0.2 1/2” 54 0.2 1/2” 54 FVW 12÷74 Total Cooling capacity (1) Sensible Cooling capacity (1) DIMENSIONS FVW L H P D (*) STD STD STD STD mm mm mm mm 12 13 14 22 23 24 32 33 34 42 43 44 52 53 54 62 63 64 72 73 74 690 500 210 90 690 500 210 90 690 500 210 90 820 500 210 90 820 500 210 90 820 500 210 90 1080 500 210 90 1080 500 210 90 1080 500 210 90 1210 500 210 90 1210 500 210 90 1210 500 210 90 1470 500 210 90 1470 500 210 90 1470 500 210 90 1470 570 275 90 1470 570 275 90 1470 570 275 90 1730 570 275 90 1730 570 275 90 1730 570 275 90 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (*) D: Feet height. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 157 5 FIW 12÷74 FAN COIL UNIT WITH CENTRIFUGAL FANS FOR BUILT-IN INSTALLATION. FROM 0,9 kW TO 7,3 kW. UNIT DESCRIPTION The water terminals of the FIW series are designed for vertical floormounted installation, or horizontal in domestic environments or the services sector including offices, hotels, restaurants, gyms and shops. If connected to a system equipped with a water cooler, the FIW fan convector generates cool air silently and immediately. Otherwise, during the winter, if combined with a heating system with boiler or heat pump, it delivers warm air to satisfy the heating needs of households and the service industry alike. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. These units can be combined with the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently. VERSIONS FIW/IV Built-in vertical unit bottom inlet and vertical delivery FIW/IF Built-in vertical unit front inlet and vertical delivery FIW/IO Built-in horizontal unit rear inlet and horizontal delivery FIW/II Built-in horizontal unit bottom inlet and horizontal delivery 158 FEATURES ACCESSORIES • Structure made of galvanized sheet complete with heat/sound insulation, regenerating filter and natural discharge condensation tray. • Centrifugal fan type directly coupled to a 6-speed singlephase electric motor, with 3 speeds connected in the standard configuration. • Heat exchanger coil with copper pipes and aluminium fins with airvent on the distributors. Loose accessories: C Auxiliary tray WS Exchanger for 4 tubes systems EH Electrical heating element S Manual dampers SG Manual dampers with grill SM ON/OFF motorized dampers SMG ON/OFF motorized dampers with grill RM Wall connection for dampers SF Supply frame VR Fan speed controls DRM Electronic control panels DRA Remote automatic control panel DRE EASY electronic control panel TA Remote room thermostat TMB Minimum temperature thermostat for VB and VR TME Minimum temperature electronic thermostat for DBM, DRM, DBA and DRA V2 3-way on/off valve for system with 2 pipes V4 3-ways on/off valves for 4 pipes system MP Micro pump for moisture TECHNICAL DATA H2O FIW 12÷74 Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg FIW 12÷74 Total Cooling capacity (1) Sensible Cooling capacity (1) Cooling Heating Supplementaly coil Air flow Sound capacity Sound pressure Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max Med. Min. Max (3) Med. Min. Power supply Max absorbed power Electrical characteristics Water connections Weights Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW ”G Kg 12 13 14 22 23 24 32 33 34 42 43 0.95 0.9 163 2.1 2.61 224 1.6 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.31 1.09 225 5.4 3.2 275 4.1 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.49 1.26 253 1.0 3.45 297 0.8 1.5 129 2.9 240 190 140 51 44 36 41 34 26 1.29 1.15 222 4.2 3.66 315 3.2 2.05 1.68 353 2.1 4.53 390 1.6 186 6.7 340 260 170 54 48 36 44 38 26 1.77 1.45 304 10.7 4.19 360 8.1 2.16 186 6.7 340 260 170 54 48 36 44 38 26 2.02 1.69 347 11.4 5.06 435 8.6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.47 1.96 425 8 5.7 490 6 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.77 2.16 476 5.2 6.35 546 3.9 2.92 251 14.6 430 340 250 50 44 35 40 34 25 2.51 2.04 432 2.4 6.44 554 15.1 3.75 322 25.7 540 420 280 54 47 37 44 37 27 3.11 2.42 535 14.2 7.03 605 10.7 3.75 322 25.7 540 420 280 54 47 37 44 37 27 0.02 1/2” 12 0.02 1/2” 12 0.02 1/2” 12 0.04 1/2” 14 0.04 1/2” 14 0.05 1/2” 18 0.05 1/2” 18 0.05 1/2” 18 0.07 1/2” 21 0.07 1/2” 21 44 52 53 54 3.54 2.71 609 9.1 7.75 666 6.8 3.75 322 25.7 540 420 280 54 47 37 44 37 27 2.9 2.48 499 4.8 7.9 679 3.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.04 3.12 695 26.2 9.01 775 19.7 4.65 400 6.9 690 530 400 56 49 43 46 39 33 4.58 3.47 788 16.7 9.93 854 12.6 4.65 400 6.9 690 530 400 56 49 43 46 39 33 0.07 1/2” 21 0.08 1/2” 24 0.08 1/2” 24 0.08 1/2” 24 186 6.7 340 260 170 54 48 36 44 38 26 230 / 1 / 50 0.04 1/2” 14 62 63 3.86 5.09 3.18 3.86 664 875 10.9 8 10.54 11.69 906 1005 8.1 5.9 6.01 6.01 517 517 13.1 13.1 910 910 730 730 510 510 58 58 53 53 44 44 48 48 43 43 34 34 230 / 1 / 50 0.16 0.16 1/2” 1/2” 33 33 64 72 73 74 5.96 4.63 1025 5.2 13.00 1118 3.8 6.01 517 13.1 910 730 510 58 53 44 48 43 34 5.16 4.18 888 21.6 13.16 1132 16.3 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 6.45 5.07 1109 15.8 14.59 1255 11.9 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 7.26 5.57 1249 10.2 16.19 1392 7.6 7.84 674 24.2 1180 810 590 62 52 44 52 42 34 0.16 1/2” 33 0.2 1/2” 42 0.2 1/2” 42 0.2 1/2” 42 FIW 12÷74 Total Cooling capacity (1) Sensible Cooling capacity (1) DIMENSIONS FIW L H P STD STD STD mm mm mm 12 13 14 22 23 24 32 33 34 42 43 44 52 53 54 62 63 64 72 73 74 440 475 195 440 475 195 440 475 195 560 475 195 560 475 195 560 475 195 760 475 195 760 475 195 760 475 195 960 475 195 960 475 195 960 475 195 1160 475 195 1160 475 195 1160 475 195 1135 545 260 1135 545 260 1135 545 260 1410 545 260 1410 545 260 1410 545 260 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 159 5 HWW/V 22÷83 eurìce WALL MOUNTED FAN COILS WITH TANGENTIAL FAN. FROM 2,1 kW TO 8,5 kW. UNIT DESCRIPTION The water terminal units of the EURÌCE series are designed for wallmounted installation in domestic environments or the services sector including offices and shops. If connected to a system equipped with a water cooler, the EURÌCE wall-mounted fan convector generates cool air silently and immediately. Otherwise, during the winter, if combined with a heating system with boiler or heat pump, it delivers warm air to satisfy the heating needs of households and the service industry alike. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. Available in the remote-controlled version, EURÌCE is serially supplied with 3-ways valve and flexible hydraulic hook-ups for easy installation and maintenance operations. VERSIONS HWW/V Standard unit with 3-ways valve and remote control FEATURES • High design appearance with rounded lines, structure in ABS with improved mechanical features resistant to aging. • Heat exchanger battery in copper tubing and aluminium fins with elevated heat exchanging surfaces; equipped with air blowing in condensation drain. • 3-way water valve incorporated in the interior. • Tangential 3-speed fan unit, maximum silent operations, air flow fins with adjustable horizontal direction and motorized deflector fin controllable via remote control. • Microprocessor control with timer for on/off programming. Program for automatic operations, cooling, heating and ventilation; nocturnal wellness program and dehumidifier. • Automatic restarting after power outage • Flexible hydraulic hook-ups for easy installation and maintenance operations. • Easy removal and cleaning of air filter, maintaining appropriate air quality. • Infrared remote control with wall support. 160 TECHNICAL DATA H2O HWW/V 22÷83 eurìce Air flow Sound pressure Electrical characteristics Water connections Weights 42 53 72 83 5.46 4 939 37 11.6 998 40 850 782 713 41 40 39 7 5.3 1204 20 15.7 1350 25 1280 1150 1019 42 41 40 8.5 6.4 1462 30 18.8 1617 37 1402 1223 1104 43 42 40 2.61 1.92 449 19 5.6 482 22 425 382 340 35 34 33 4.34 3.26 746 22 9.6 826 27 750 680 612 38 37 36 0.012 0.012 0.035 0.035 0.06 0.06 IN/OUT ”G 1/2-1/2 1/2-1/2 5/8-5/8 5/8-5/8 3/4-3/4 3/4-3/4 Transport weight Kg 9 10 16 17 23 24 Water flow (1) Pressure drops (1) Heating capacity (2) Water flow (2) Pressure drops (2) Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Absorbed power 230 / 1 / 50 HWW/V 22÷83 eurìce Heating 32 2.1 1.59 361 18 4.6 396 21 374 340 306 34 33 32 Sensible Cooling capacity (1) Cooling 22 kW kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) V/Ph/Hz kW Total Cooling capacity (1) DIMENSIONS HWW/V L P H STD STD STD mm mm mm DIMENSIONAL 22 32 42 53 72 83 880 180 298 990 180 305 1172 210 360 1172 210 360 1450 220 365 1450 220 365 NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 80 °C. • Inhibited ethylene glycol can be added to the water. 5 161 5 TCW 42÷104 WATER CASSETTE FROM 2,2 kW TO 10,2 kW. UNIT DESCRIPTION The water cassette of the TCW series has been designed and produced to be installed in false ceilings, in domestic environments or the services sector including offices, hotels, restaurants, gyms and shops. If connected to a system equipped with a water cooler, the TCW terminal unit generates cool air silently and immediately. Otherwise, during the winter, if combined with a heating system with boiler or heat pump, it delivers warm air to satisfy the heating needs of households and the service industry alike. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. The TCW series, in addition to having a rich set of accessories to complete the unit, also has an attractive intake grille that integrates perfectly in the surrounding environment and adjustable deflectors to distribute the air in the room in an ideal manner. This unit can be combined with the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently. VERSIONS TCW Base unit TCW/V Unit with 3-ways on/off valve TCW/WB Unit with exchanger for 4-pipes system TCW/WB/V Unit with coil for 4-pipes system and 3-ways on/off valve TCW/EH Unit with electric heater TCW/EH/V Unit with electric heater and 3-ways on/off valve FEATURES • Structure for insulated recess fitting, limited depth (287 mm) and dimensions compatible with the standard double-ceiling modules (600x 600 mm and 600x1200 mm); specially designed for easy installation and maintenance of the hydraulic and electrical connections, accessible starting from the front panel grille. • Casing with panels in insulated galvanized sheet; combined air intake/suction grille; manual adjustment for diffusion of air on the four sides; possibility of closing one or two air intake sides; suction in middle with regenerable filter; precut holes for connection to an external air intake and for connection to a branch duct for conditioning an adjoining room. • Combined air diffusion/suction grille with air filter and manually adjustable air diffusion on the 4 sides with suction in middle. • Centrifugal fan turbine with direct feed. The motors, mounted on elastic suspension and equipped with internal thermal safety, are 3-speed. • Lift pump with float and detection at 3 levels (On-Off-Alarm) of condensation for lift in the upper part of the box. Discharge occurs by gravity, outside the appliance (lift height up to 600 mm). 162 • Heat exchanger coil with copper pipes and aluminium fins with air vent on the distributors. • Electric heater the boxes are factory-fitted (optional) with an electric heater (heating elements) thermally protected against any abnormal temperature increase by means of two automatic or manual-reset thermostats. • Regenerable-type air filter, accessible after opening the combined air intake/suction grille. • Internal electric control and protection board with power supply terminal block for connection to terminals without screws and multi-output (42÷54) auto-transformer. Outer placed electrical board (84-104). ACCESSORIES Loose accessories: DRM Control panel DRA Automatic control panel V2 3-way on/off valve for system with 2 pipes V4 3-ways on/off valves for 4 pipes system TECHNICAL DATA H2O TCW 42÷104 Total Cooling capacity (1) Heating 2-pipes unit Riscaldamento 4 tubi Air flow Sound pressure Electrical characteristics Electric heating (EH) Water connections Weights Water flow (1) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Heating capacity (2) Water flow (2) Pressure drops Max Med. Min. Max (3) Med. (3) Min. (3) Power supply Max absorbed power Med. absorbed power Min. absorbed power Power supply Absorbed power 2-pipes 4-pipes Transport weight kW kW l/h kPa kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) V/Ph/Hz kW kW kW V/Ph/Hz kW ”G ”G Kg 44 54 84 104 2.2 1.77 378 12.7 5.8 499 18.5 2.2 189 3.2 700 460 420 39 27 24 3.5 2.7 602 16.2 7.8 671 23.5 3.2 275 4.7 700 460 420 39 27 24 6.5 4.87 1118 16.7 18.2 1565 22.9 ------1550 1350 1100 48 40 37 10.2 7.75 1754 25.7 19.6 1686 18.2 9.5 817 5 1725 1360 1075 48 41 46 0.06 0.04 0.03 0.08 0.05 0.04 0.2 0.18 0.16 0.22 0.19 0.18 1.5 1/2” 1/2” - 1/2” 26 2.3 1/2” 1/2” - 1/2” 26 5 3.78 850 14.7 9.9 851 14.6 4.9 421 4.1 760 515 460 44 36 31 230/1/50 0.11 0.07 0.05 230/1/50 2.6 3/4” 1/2” - 3/4” 30 4.3 1” --49 5.2 1” 1” - 1/2” 55 TCW 42÷104 Sensible Cooling capacity (1) Cooling 42 DIMENSIONS TCW L P H STD STD STD mm mm mm DIMENSIONAL 42 44 54 84 104 571 571 287 571 571 287 571 571 287 1171 571 287 1171 571 287 NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) At a distance of 1 m and with reverberation time of 0.5 s. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 163 5 UTW 63÷544 MODULAR DUCTABLE TERMINAL UNITS. FROM 4,6 kW TO 43 kW. UNIT DESCRIPTION The modular water terminal units of the UTW series are the ideal solution to meet the air treatment needs of systems including distribution through ducting or directly into the room and installation in false ceilings or in service rooms. If equipped with a water cooler, they generate cool air silently and immediately. Otherwise, during the winter, if combined with a heating system with boiler or heat pump, they deliver warm air to satisfy the heating needs of households and the service industry alike. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. This product range, available for 2- and 4-pipe systems, is complete with various accessories such as: outdoor air intake plenum, mixing section with dampers room delivery plenum for flexible ducts and resistance heating section. These units can be combined with the innovative monitoring and control system CLIMAFRIEND which allows to program and obtain a level of comfort intuitively and efficiently. VERSIONS UTW Base unit 164 FEATURES ACCESSORIES • Structure in galvanized sheet (63÷274) or in prepainted metal sheet (333÷544), entirely lined with heat/sound insulation material. • Centrifugal type fan with double intake, statically and dynamically balanced to reduce vibration and noise to a minimum, directly coupled on single-phase 3-speed electric motor (63÷274) or with belt and pulley transmission, connected to 3-phase single speed electric motor (333÷544). • Heat exchanger in copper tubes and aluminium fins, complete with air vent and drain pan. • Air filter made of recyclable synthetic material class EU3; inspection is foreseen from the bottom part (63÷274) or side part (63÷544). • Air bleed valves these are found on the water connections of the coil and make it possible to bleed air from the coil. • Electrical panel comprising a terminal board for wiring to room control panel and power supply. Loose accessories: C Auxiliary moisture drain pan AF Filter section SF Supply frame GRI/R Intake grille+air filter BM Supply grille with adjustable finns PR Intake plenum MB Mixing box with damper SP Supply plenum P3 Supply plenum for flexible ducts WS Section for 4-pipes system EH1 Electric heater section EH2 Electric heater section SM Servomotor for damper VR Fan speed control DRM Control panel DRA Automatic control panel V2 3-way on/off valve for system with 2 pipes V4 3-ways on/off valves for 4 pipes system TECHNICAL DATA H2O UTW 63÷544 Total Cooling capacity (1) Water flow (1) Pressure drops Heating capacity (2) Heating Water flow (2) Pressure drops Max (3) Air flow Med.(3) Min. (3) Max (4) Sound pressure Med. (4) Min. (4) Power supply Max absorbed power Electrical characteristics Max absorbed current Inrush current Water connections Weights Transport weight Heating capacity (2) Water flow (2) WS Hot water coil Pressure drops Water connections Power supply Heating capacity EH1 Electric heating Max absorbed current Steps Power supply Heating capacity EH2 Electric heating Max absorbed current Steps kW kW l/h kPa kW l/h kPa m³/h m³/h m³/h dB(A) dB(A) dB(A) V/Ph/Hz kW A A ”G Kg kW l/h kPa ”G V/Ph/Hz kW A n° V/Ph/Hz kW A n° 93 104 4.6 3.5 791 14 9.8 843 23 1000 800 600 45 40 34 7.5 6 1290 19 15.5 1333 17 1600 1200 850 44 38 30 9.1 7.1 1565 21 19.7 1694 22 1700 1300 900 45 39 31 0.09 1 1.4 3/4” 29 6.8 585 10 3/4” 0.15 2.1 2.3 3/4” 42 10.9 937 11 3/4” 3 4.3 1 4 8.7 1 6 8.7 1 8 17.4 1 133 153 233 274 333 414 464 544 10.5 13.1 8.4 9.8 1806 2253 18 24 21.6 25.9 1858 2227 40 25 2200 2500 1800 2000 900 1300 47 49 43 44 28 35 230 / 1 / 50 0.15 0.15 0.15 2.1 2.1 2.1 2.3 2.3 2.3 3/4” 3/4” 3/4” 44 57 65 11.5 13.5 16 989 1161 1376 12 15 14 3/4” 3/4” 3/4” 400 / 3 + N / 50 4 4 6 8.7 8.7 13 1 1 1 400 / 3 + N / 50 8 8 12 17.4 17.4 26.1 1 1 1 15.7 13 2700 24 35.5 3053 23 3900 3000 1900 51 45 35 20.7 16.7 3560 26 46.3 3982 32 4500 3800 2000 55 51 37 25.9 20.1 4455 29 60.1 5169 39 5500 ----56 ----- 42.8 33.2 7362 26 97.1 8351 34 9000 ----58 ----- 0.42 3.9 5.5 1” 67 20.3 1746 19 3/4” 0.6 6.1 8.5 1” 70 22.2 1909 23 3/4” 0.75 3.3 5.5 1½” 168 47.4 4076 10 1¼” 6 13 1 6 13 1 ------- 12 26.1 1 12 26.1 1 ------- 31.7 38.1 24.6 29.6 5452 6553 14 29 75.8 91.8 6519 7895 14 48 6800 7700 --------57 57 --------400 / 3 / 50 1.1 1.1 3.9 3.9 6 6 1½” 1½” 168 173 58.4 64 5022 5504 15 10 1¼” 1¼” ----------------------------- UTW 63÷544 Sensible Cooling capacity (1) Cooling 63 1.5 5.4 6.5 1½” 175 75.1 6459 14 1¼” -------------- DIMENSIONS UTW L P H STD STD STD mm mm mm 63 93 104 133 153 233 274 333 414 464 544 645 455 295 1005 455 295 1005 455 295 1105 505 325 1345 540 325 1345 540 375 1345 540 375 1400 800 800 1400 800 800 1400 800 1050 1400 800 1050 DIMENSIONAL NOTES (1) Ambient air temperature 27 °C d.b.; 19 °C w.b.; Water temperature 7/12 °C; (2) Ambient air temperature 20 °C d.b. Water temperature 70/60 °C; (3) One spees 3-phase electrical motors for units 333,414,464,544. (4) At a distance of 1 m and with reverberation time of 0.5 s. (N.B.) • Maximum operating pressure 1000 kPa. • Maximum inlet water temperature 90 °C. • Inhibited ethylene glycol can be added to the water. 5 165 5 DBM-DBA / DRM-DRA ELECTRONIC CONTROL BOARDS FOR FAN COIL UNITS AND HYDRONIC TERMINAL UNITS. UNIT DESCRIPTION DBM/DRM DBM and DBA are control boards to be fitted in a specially provided space inside the fan coil units; as such they have a connector for easy connection to the terminal board of the units. In this instance the temperature probe is placed close to the air intake, that is in the lee of the fan. Otherwise, DRM and DRA are control boards to be fixed on the wall; as such they are suitable for all type of hydronic terminal units. In this instance the temperature probe is inside the control board itself so that it is very important to place the control not in the nearby of any heating source. DBA/DRA VERSIONS DBM / DBA Built-in control panel DRM / DRA Wall mounting control panel FEATURES Use • DBM and DRM, manual-acting, required by terminal units for two pipes plant with/without three way ON/OFF valves and for four pipes plant without three way ON/OFF valves. • DBA and DRA, manual and automatic-acting, required by terminal units for two pipes plant, four pipes plant and for two pipes plant with electrical heater with/without three way ON/OFF valves. Functions DBM and DRM • Manual selection for fan speed; • Manual selection for operation mode; • Manual selection for required room temperature; • Control of the minimum temperature thermostat (optional) both in heating mode (HOT START) and cooling mode (TOO COOL); pre designed values for minimum water temperature are 30°C for heating mode and 12°C for cooling mode. Functions DBA and DRA • Manual or automatic selection for fan speed; using “AUTO” function the control board select automatically fan speed according to ΔT between designed set point and room air temperature. • Manual or automatic selection for operation mode of the units; using “AUTO” function the control select automatically operation mode of the unit according to air temperature and water temperature. 166 • Control of the minimum temperature thermostat (standard for DBA and DRA) both in heating mode (HOT START) and cooling mode (TOO COOL); pre-designed values • for minimum water temperature are 35°C for heating mode and 25°C for cooling mode. Besides the minimum temperature thermostat allows, in this instance, the “AUTOMATICAL CHANGE OVER” just detecting inlet water temperature and as such has to be always installed in this case. • PERIODIC VENTILATION: this function is present only if the control is fitted inside the unit. It allows the temperature probe, fitted in the lee of the fan, to get a more precise value for the air temperature. • Control in ON/OFF MODE of the auxiliary electrical heater in heating mode (two pipes system with electrical heater); in this instance, the “POST VENTILATION” function allows the discharge of the heat produced by the electrical heater itself after its disconnection. • ANTIFREEZE: this function elude the unit freezing during winter stop; there is a thermostat always working for hot temperature with a set point at 8°C, this thermostat disregards permissions of the water probe and the set operation mode. CLIMAFRIEND CHECK AND SUPERVISION SYSTEM FOR AIR CONDITIONING. The intelligent check of commercial and domestic climate. Innovative. Climafriend is a new system for climate management in domestic and commercial venues; simple to install it borns from the need to make easy the user in the obtaining of the best conditions of comfort in the places where he lives and works. Immediate. With touch-screen monitor, of that the user interface is provided. It is possible to access immediately to the system functions laying out the working, automatic or manual, of the single uses and the relative hourly/weekly scheduling on different temperature levels. Effective. Suitable to be interfaced with any type of electronic controller provided that fi tted out with Modbus RS 485 serial communication card, Climafriend manages, further to the chiller and terminals, till to a maximum of 30 units, also the boiler allowing a big content of energetic consumption’s and the system management costs. VERSIONS CLIMAFRIEND Supervision system DBM-DBA - DRM-DRA / CLIMAFRIEND UNIT DESCRIPTION ACCESSORIES Features and accessories: TSC 15” Touch screen color display AP Software IS RS 485 serial interface DBA/W Built-in automatic control panel DRA/W Remote automatic control panel DY ON/OFF control for boiler thermostat 5 167 2013 PRODUCT GUIDE 200CLD2000XBXX - 06/2013 - 1000 2013 PRODUCT GUIDE G.I. INDUSTRIAL HOLDING S.p.A. participates in the ECC programme for LCP-HP and FCU. Check on-going validity of certificate: www.eurovent-certification.com or www.certiflash.com