1 CHA/FC 642÷2204 AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SEMI-HERMETIC COMPRESSORS AND SHELL AND TUBE EXCHANGERS. FROM 165 kW TO 600 kW. UNIT DESCRIPTION The water coolers of the CHA/FC 642÷2204 series offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensation battery, thus saving energy by not operating the unit’s semihermetic compressors. A 3-way valve system is commanded by an electronic microprocessor controller that manages the entire unit, allowing functioning in CHILLER, FREECOOLING or MIXED (simultaneously CHILLER and FREE COOLING) modes. The product range includes 13 models composed of versions with tank, with pump or with tank and pump. VERSIONS CHA/FC Cooling only FEATURES ACCESSORIES • Self-supporting galvanized steel frame protected with polyester powder painting. • Semi-hermetic compressors type complete with cranckcase heater, oil sight glass, incorporated thermal protection and shut off valves. • Axial fans directly coupled to an electric motor with external rotor. • Condenser made of FREE-COOLING copper tube and aluminium finned coil. • Shell and tube type evaporator, with two indipendent refrigerants circuits and one water circuit. • R407C refrigerant. • Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. • Microprocessor control and regulation system. Factory fitted accessories: IM Protection module SL Unit silencement BT Low Temperature Kit HRT/P Total heat recovery in parallel SP Inertial tank PU Single circulating pump PD Double circulating pump SPU Inertial tank and single circulating pump SPD Inertial tank and double circulating pump MF Muffler RF Cooling circuit shut off valves SS Soft start CP Potential free contacts Loose accessories: MN High and low gauges MO Compressor oil gauges CR Remote display IS RS 485 serial interface RP Metallic guards for condenser AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 64 TECHNICAL DATA R407C CHA/FC 642÷2204 Unit with SPU accessory Sound pressure Weights kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections DN STD (3) dB(A) SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg CHA/FC 642÷2204 COOLING CAPACITY (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power Unit with SPU accessory Sound pressure Weights kW kW °C kW n° n° n° l/s kPa DN n° m³/s V/Ph/Hz A A kW Pump available static press. kPa Storage water volume l Expansion vessel l Water connections DN STD (3) dB(A) SL (3) dB(A) Transport weight (4) Kg Transport weight (5) Kg Operating weight (4) Kg Operating weight (5) Kg 642 702 802 902 1002 1102 1202 165 57.6 5.2 5.9 2 191 59.6 4.2 5.9 2 219 73.5 3.9 5.9 2 241 79.3 3 5.9 2 Semi-hermetic 2 4 12.46 94 100 6 19.17 400 / 3 / 50 168 300 4 108 1100 35 100 66 64 3050 3400 3320 4770 261 86.7 4 7.8 2 300 96.7 2.9 7.8 2 326 106 2.1 7.8 2 2 2 2 8.53 62 100 6 20 9.87 71 100 6 20 11.32 98 100 6 19.17 124 195 4 172 660 24 100 66 64 2730 3075 2930 3935 144 226 4 154 660 24 100 66 64 2830 3165 3080 4075 168 300 4 117 1100 35 100 66 64 3000 3350 3270 4720 2 2 2 13.49 81 100 8 24.44 15.5 72 100 8 24.44 16.85 65 125 8 24.44 186 332 4 109 1100 35 100 66 64 3240 3610 3530 5010 240 430 5.5 146 2000 80 100 66 64 3520 3890 3810 6235 260 440 5.5 145 2000 80 125 66 64 3800 4200 4100 6545 1502 1602 1604 1804 2004 2204 354 114 1.3 7.8 2 363 126 2.3 9.8 2 438 145 0.6 9.8 4 482 157 -0.3 9.8 4 522 167 -1 9.8 4 600 197 0.4 20 4 2 2 2 2 2 2 18.3 92 125 8 24.44 18.76 79 125 10 29.44 22.64 72 125 10 29.44 24.92 81 150 10 29.44 27 90 150 10 29.44 31 79 150 10 40.28 296 567 5.5 113 2000 80 125 66 64 4130 4550 4500 6950 296 567 5.5 124 2000 80 125 67 65 4480 4950 4900 7400 336 468 5.5 108 2000 80 125 67 65 4780 5350 5330 7800 336 468 7.5 129 2000 80 150 67 65 4830 5400 5405 7850 480 670 7.5 113 2000 80 150 67 65 5000 5480 5600 8030 480 670 7.5 106 2000 80 150 71 69 5350 5950 6000 8500 Semi-hermetic 4 400 / 3 / 50 CHA/FC 642÷2204 COOLING CAPACITY (1) Cooling Absorbed power (1) air temperature (2) Free-cooling cycle Absorbed power (2) Quantity Type Compressors Refrigerant circuits Capacity steps Water flow Evaporator Pressure drops Water connections Fans Condenser Air flow Power supply Electrical Max. running current characteristics Inrush current Pump nominal power 1 DIMENSIONS CHA/FC L P H STD STD STD mm mm mm 642 702 802 902 1002 1102 1202 1502 1602 1604 1804 2004 2204 4400 2200 2265 4400 2200 2265 4400 2200 2265 4400 2200 2265 5500 2200 2265 5500 2200 2265 5500 2200 2265 5500 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 6700 2200 2265 DIMENSIONAL NOTES CLEREANCE AREA (1) CHA/FC 642÷2204 A (*) B C D mm mm mm mm 1000 1800 500 1800 (2) (3) (4) (5) (*) Chilled water (with ethilenic glycol at 30%) from 15° to 10°C, ambient air temperature 35°C. Ambient air temperature at wich the cooling capacity indicated in point (1) is reached. Sound pressure level measured in free field conditions at 1 m from the unit and. According to ISO 3744. Unit without tank and pump. Unit with tank and pump. A SIDE: Electrical board side. 65