The POB-AD series COIL TESTER & POWER SUPPLY Manual 1.800.561.8187 www. .com information@itm.com POB-AD series Contents Contents 1 Introduction……………………………………………………………………………………………...………4 1.1 Safety Instructions…………………………………………………………………………………………4 1.1.1 Safety Terms and Symbols………………………………………………………………………4 1.1.2 Terms of Use………………………………………………………………………………………4 1.1.3 Orderly Practices and Procedures………………………………………………………………4 1.1.4 Instrument Maintenance…………………………………………………………………………..5 1.1.5 Operator Qualifications……………………………………………………………………………5 1.1.6 Safe Operating Procedures………………………………………………………………………5 1.2 Power Supply……………………………………………………………………………………………….6 1.3 Intended Use………………………………………………………………………………………………..6 2 Description……………………………………………………………………………………………..………..7 2.1 Front Panel Components…………...……………………………………………………………………..7 2.2 Rear Panel Components…………………………………………………………………………………..8 2.3 Setting the POB-AD's Language………………..…………………………………….………………….8 2.4 Setting the POB-AD's Time and Date……………….………………………………..…………………9 3 Getting Started………………………………………………………………………………………..……….10 3.1 Connecting the POB-AD to a Test Object………………………………………….……….…………10 4 Setting the Test Parameter………………………………………………………………………………..11 4.1 Volt DC and Volt AC menus……………………………………………………………………………..11 4.2 MTV DC …………………………………………………………………………………………………...11 4.3 EXT DC and EXT AC menus……………………………………………………………………………13 5 Testing using the POB-AD………………….………………………………………………..……………...14 5.1 Spring-charging Motor……………………………………………………………………………………14 5.1.1 Important notes while testing with the POB-AD..………………………………….………………….15 5.2 DC Coils Testing …………………………………………………………………………………………15 5.2.1 Manual test……………………………………………………………………………………….15 5.2.2 Automatic test…………………………………………………………………………………….16 5.3 AC Coils Testing …………………………………………………………………………………………17 5.3.1 Manual test………………………………………………………………………………………..17 5.4 Using the POB-AD with a Circuit Breaker Analyzer……………………………….………………...19 5.4.1 Using the EXTERNAL connector……………………………………………………………...20 5.4.2 Using the EXT DC menu……………………………………………………………………….21 5.5 Duty Cycles………………………………………………………………………………………………..22 6 Error Messages……………………………………………………………………………………………….23 6.1 Error Message "Overcurrent"……………………………………………………………………………23 6.2 Error Message "Overheat"……………………………………………………………………………….23 6.3 Error Message "No activation"…………………………………………………………………………..23 6.4 Error Message "Malfunction"…………………………………………………………………………….24 7 Troubleshooting……………………………………………………………………………………………….25 7.1 Voltage test………………………………………………………………………………………………..25 7.1.1 DC voltage measurement check……………………………………………………………….25 7.1.2 AC voltage measurement check……………………………………………………………….25 7.2 Current test………………………………………………………………………………………………..26 1.800.561.8187 M-P0X0AD-200-EN www. .com 2 information@itm.com POB-AD series Contents 8 Customer Service…………………………………………………………………………………………..28 9 Packing the Instrument for Shipment……………………………………………………………………..28 10 Technical Data .............................................................................................................................. 29 10.1 Mains Power Supply……………………………………………………………………………………...29 10.2 Output data…………...………..…………………………………………………………………………..29 10.3 Measurement……………………………………………………………………………………………...29 10.4 Environmental conditions………………………………………………………………………………..29 10.5 Dimensions and Weight………………………………………………………………………………….29 10.6 Safety Standards………………………………………………………………………………………….29 10.7 Electromagnetic compatibility (EMC)…………………………………………………………………...29 11 Accessories……………………………………………………………………………………………………30 Manufacturer Contact Information……………………………………………………………………………….31 Manual Version: M-P0X0AD-200-EN This Manual refers to the following POB-AD models and their corresponding firmware versions Model POB30AD POB40AD 1.800.561.8187 M-P0X0AD-200-EN www. Firmware versions PA1-6.09 PA1-6.09 .com 3 information@itm.com POB-AD series Description 1 Introduction This manual provides helpful instructions on how to use the POB-AD series instruments. The following instructions will help a user avoid unsafe situations, reduce maintenance costs and ensure reliability and durability of the POB-AD series instruments. The POB-AD series must be used in accordance with all existing safety requirements and regulations based on national/local standards for accident prevention and environmental protection. In addition, the relevant international standards are listed in the “Technical data” section of this document. 1.1 Safety Instructions Safety is the responsibility of the user. Before operating the POB-AD, please read the following safety instructions carefully. It is not recommended to use the POB-AD (or even turn it on) without careful observation of the instructions listed in this Manual. The POB-AD should only be operated by trained and authorized personnel. 1.1.1 Safety Terms and Symbols Terms in this Manual. The following terms may appear in this manual: WARNING: Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION: Caution statements identify conditions or practices that could result in damage to this product or to other property. Symbols on the Device. The following symbols may appear on the device: Refer to Manual Protective Earth Terminal 1.1.2 Terms of Use The POB-AD shall be used only if it is in a good technical condition. Its use shall be in accordance with local safety and industrial regulations. Adequate precautions must be taken to avoid any risks related to high voltages associated with this equipment and nearby objects. The POB-AD is intended exclusively for application purposes specified in the ”Intended Use” section. The manufacturer and distributors are not liable for any damage resulting from wrong usage. The user bears responsibility in case of not following the instructions defined in this document. Do not remove the protective casing of the POB-AD. All service and maintenance work must be performed by qualified personnel only. 1.1.3 Orderly Practices and Procedures The Manual shall always be available on the site where the POB-AD is used. M-P0X0AD-200-EN 1.800.561.8187 www. 4 .com information@itm.com POB-AD series Description Before using the POB-AD, all personnel (even personnel who only occasionally, or less frequently, work with the POB-AD) assigned to operate the POB-AD should read this Manual. Do not make any modifications, extensions, or adaptations to the POB-AD. Use the POB-AD only with the original accessories provided by its manufacturer. Use the POB-AD and its original accessories for the device’s intended use only. 1.1.4 Instrument Maintenance The device should be kept clean in order to prevent excessive dust or other contaminants affecting its operation. It should be cleaned with water/isopropyl alcohol after any dirt/contaminants are noticed on its surfaces. 1.1.5 Operator Qualifications • • Testing with the POB-AD should only be carried out by authorized and qualified personnel. Personnel receiving training or any type of instructions on the POB-AD should remain under the constant supervision of an experienced operator while working with the test set and the test object. 1.1.6 Safe Operating Procedures Hazardous voltages of up to 400 V can occur inside the POB-AD. Therefore, it is not permitted to remove the protective casing of the POB-AD. Hazardous voltages exist on the terminals of the POB-AD when the red LED is lit. Never assume that the connections are safe even if this LED is off. Switch off and unplug the POB-AD before touching the connections, especially if a fault is suspected. Before putting the POB-AD into operation, check the test set for any visible damage. Do not operate the POB-AD under wet or moist conditions (condensation). Do not operate the POB-AD if explosive gas or vapors are present. Only the external devices which meet the requirements for SELV equipment according to EN 60950 or IEC 60950 should be connected to the POB-AD through the serial interface. When setting up the POB-AD, make sure that the air slots of the test set remain unobstructed. Removing the POB-AD protective casing will void the warranty. Any work inside the instrument without prior authorization from DV Power will also void the warranty. If the POB-AD seems to be malfunctioning, please contact the DV Power Support Team (refer to the "Manufacturer Contact Information” section) after previously checking the “Error Messages” section. Prior to connecting the POB-AD, ensure that the circuit breaker (object) to be tested is completely deenergized and isolated from both the line and the load. Every terminal should be checked and verified before connecting the POB-AD. Ground connections may be left in place. Do not use the POB-AD without the extra protective ground cables supplied with the POB-AD. It must never be operated in a non-grounded configuration as this may result in an electric shock to the user or damage to the POB-AD. Always establish this connection first before establishing any other connections and remove this connection as the very last one. M-P0X0AD-200-EN 1.800.561.8187 www. 5 .com information@itm.com POB-AD series Description 1.2 Power Supply • • • Supply the POB-AD only from a power outlet which is equipped with the protective ground. Besides being supplied from phase – neutral (L1-N, A-N), the POB-AD may also be supplied from phase to phase (e.g., L1-L2; A-B). However, the voltage must not exceed 264 V AC. Please refer to the section “Technical Data”. The POB-AD should be positioned in such a way that it is possible to safely disconnect it from the power supply at any moment. WARNING / AVERTISSEMENT This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Il s'agit d'un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des interférences radio, auquel cas l'utilisateur peut être amené à prendre des mesures adéquates. 1.3 Intended Use The Coil Tester & Power Supply (POB-AD) is designed for a circuit breaker testing. It is developed for use in switchyards, high power and industrial environment. Typical application area for POB-AD in testing high power circuit breakers: circuit breaker operation condition, supplying of spring-charging motors, providing a power supply in the tests involving circuit breaker analyzers, minimum trip voltage test of circuit breaker’s coils. Any other use of the POB-AD than the ones mentioned above is to be considered improper and will not only invalidate all customer warranty claims but also exempt the manufacturer from its liability for repair or exchange. The POB-AD is intended to operate breaker coils and spring charging motors as a part of commissioning and maintenance testing. The POB-AD generates filtered DC or AC voltage (50Hz, 60 Hz; true RMS). It eliminates the use of stationary batteries or converters during testing. Output voltage is selectable from 10 V to 300 V DC or 10 V to 250 V AC (50Hz, 60 Hz; true RMS). M-P0X0AD-200-EN 1.800.561.8187 www. 6 .com information@itm.com POB-AD series Description 2 Description 2.1 Front Panel Components Display UP/DOWN buttons to select a menu and define test parameters LEFT/RIGHT buttons to navigate through the active menu STOP button to stop the test, to acknowledge the alarm buzzer and return to the Volt DC menu ENTER button to change Volt DC/Volt AC/MTV DC/MTV AC/EXT DC menu and to confirm the defined Language, Time and Date COILS button Press this button to start generating a continuous DC/AC voltage on the COIL outputs (breaking and closing). Test voltages must be selected beforehand. MOTOR button Press this button to generate a DC voltage on the MOTOR output. Test voltages must be selected beforehand. LEDs C LED flashes during the COIL test, and M LED flashes during the MOTOR test. C and M LEDs lit continuously in case of an operational error. M-P0X0AD-200-EN 1.800.561.8187 www. 7 .com information@itm.com POB-AD series Description Voltage AC/DC output for the breaking coil Voltage AC/DC output for the closing coil Voltage DC output for the spring-charging motor 2.2 Rear Panel Components Power switch Connector for the mains power supply I – POB-AD is turned on. 0 – POB-AD is turned off. Device grounding connector For protection against parasitic currents or voltages, always connect the POB-AD’s grounding connector to protective ground (PE). Use only the originally provided cable. For safety reasons, always establish this connection as the first one before you do any other connections, and separate this connection as the very last one. Ventilation 2.3 Setting the POB-AD’s Language To set POB-AD’s language, press the LEFT button two times in order to move the cursor to the upper line, and then UP button to select the Language menu. Figure 2-1: The Language menu M-P0X0AD-200-EN 1.800.561.8187 www. 8 .com information@itm.com POB-AD series Description Move the cursor to the bottom line using the LEFT/RIGHT buttons, and select the language of your choice using the UP/DOWN buttons. Pressing ENTER to confirm, brings back the Volt DC menu. Pressing STOP to cancel, brings back the Volt DC menu. 2.4 Setting POB-AD’s Time and Date To set the POB-AD’s internal time and date, press the LEFT button two times, and then two times UP button to select the Time menu. Figure 2-2: The Time menu showing the POB-AD’s internal time and date Move the cursor to the position of your choice using the LEFT/RIGHT buttons, and change the value with the UP/DOWN buttons. Pressing ENTER to confirm, brings back the Volt DC menu. Pressing STOP to cancel, brings back the Volt DC menu. M-P0X0AD-200-EN 1.800.561.8187 www. 9 .com information@itm.com POB-AD series Setting Test Parameters 3 Getting Started 3.1 Connecting the POB-AD to a Test Object Before connecting the circuit breaker to the POB-AD, make sure that: the breaker is disconnected or separated from its circuit on both sides in accordance to the national safety regulations; always comply with local safety regulations when using the Coil tester & power supply POB-AD, the substation DC system is disconnected, the breaker is properly grounded to the protective ground (PE), The POB-AD itself is properly grounded. To do so, connect the grounding screw on the back of the POB-AD’s to PE using the grounding cable. With the POB-AD turned off, connect the appropriate cables to the breaker’s coils and spring-charging motor. Note: Cables between the POB-AD and other equipment are to be connected and removed ONLY when the POB-AD is switched off. Always connect measuring cables to the POB-AD instrument first and then to the test object; and when disconnecting, always disconnect cables from the test object first and after that from the POB-AD. The grounding cable PE should be disconnected last. Otherwise a life threatening situation may occur. The circuit breaker has to be disconnected from its circuit on both sides in accordance with the national safety regulations; always comply with the local safety regulations when using the POB-AD. Figure 3-1: Connecting a circuit breaker coils and spring-charging motor to POB-AD M-P0X0AD-200-EN 1.800.561.8187 www. 10 .com information@itm.com POB-AD series Setting Test Parameters 4 Setting the Test Parameters 4.1 Volt DC Please turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off (Figure 4-1). Menu name Time Figure 4-1: The Volt DC menu Spring-charging motor’s test voltage The DC test voltages for coils and spring-charging motor test voltage can be defined using the LEFT/RIGHT buttons in the Volt DC menu. Their individual values can be selected using the UPIDOWN buttons. The test voltages in Volt 50Hz and Volt 60Hz menu can be selected in the same way (Figure 4-2). Menu name Time Figure 4-2: The Volt 50Hz and Volt60Hz menu Coil’s test voltage Spring-charging motor’s test voltage 4.2 MTV DC This section describes how to perform the Minimum Trip Voltage test with the POB-AD device. Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Press the ENTER button two times to select the MTV DC menu. Once the MTV DC menu is selected, please define the minimum (initial) and maximum DC test voltage along with the voltage step for the minimum trip voltage test. To ensure that circuit breaker operation is within specifications under the most rigorous conditions placed on the substation tripping supply, circuit breaker trip coils are designed to work with a minimum tripping voltage much below the nominal battery voltage. The minimum trip voltage test is described in a number of international and national standards such as IEC 56, ANSI C37.09 etc. Minimal trip voltage test of circuit breaker’s coils could be conducted in two ways: M-P0X0AD-200-EN 1.800.561.8187 www. 11 .com information@itm.com POB-AD series Setting Test Parameters 1. Manual: Pushing the TRIG button, a pre-selected DC voltage lasting 140 ms (milliseconds) is brought to the selected coil. Voltage value is increased manually until the coil is actuated. 2. Automatic: In the MTV DC menu, by pushing TRIG button a pre-selected minimal DC voltage is brought to a desired coil, lasting 100 ms. If the coil is not actuated, after 900 ms of waiting time, the voltage is automatically increased for a preselected step (value 1 V to 19 V), and the instrument repeats this procedure. Test could have two possible outcomes: The coil is actuated; in which case the voltage and maximum current are registered, The maximum pre-selected test voltage is reached without coil actuation, which is indicated by "No activation" message at the display, and announced by sound and light alarm. The POB-AD is designed to be used as an independent instrument or to provide a power supply in a combination with the Circuit Breaker Analyzer. When working with a Circuit Breaker Analyzer, the POB-AD and Circuit Breaker Analyzer should be connected using the EXTERNAL connector on the front panel of the POB-AD. The motor and coil voltage should be selected in the Volt DC and Volt 50Hz/ Volt 60Hz menus. By pressing the MOTOR button, a breaker spring is charged. By pressing the COILS button, a pre-selected voltage is generated at the coil outputs. The coils are triggered from the Circuit Breaker Analyzer. The POB-AD instrument serves as a voltage supply in this case. The voltage is generated at the coil outputs until the STOP button is pushed. Spring-charging motor is tested in the following way: - a pre-selected DC voltage from the POB-AD is brought to the motor terminals (maximum currents, and their duration data are described in the 5.5 section „Duty Cycles"). - after the motor supply from the instrument motor terminals stops, the POB-AD will automatically switch to the Result menu. The display will show total time of the test duration as well as the maximum current value reached in that period. It will not display the startup motor current. This behavior will occur only if the current reached a value of 500 mA or higher. In case the test current recorded was bellow 500 mA, the device will show no results in the Result menu. It will behave as the test has not been performed at all. Time Menu name Figure 4-3: The MTV DC menu Test parameters M-P0X0AD-200-EN 1.800.561.8187 www. 12 .com information@itm.com POB-AD series Setting Test Parameters Using the LEFT/RIGHT buttons move the cursor on the display to the position of Umin (start) and Umax (end) voltage level (here 10,0 V and 40,0 V), and voltage step fields (here 1,5 V), then using UP/DOWN buttons select desired values in each of them. 4.3 EXT DC menu The Ext DC menu is used for setting up the coils and spring-charging motor voltage values on the POB-AD when using the External Connector on the device. The External Connector is used to bring the triggering signal from another device (usually a Circuit Breaker Analyzer). The connection is done using the External Trigger Cable. Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Press the ENTER button four times to select the Ext DC menu. Using the LEFT/RIGHT buttons in the Ext DC menu, select the DC test voltage fields for coils and springcharging motor. To select the appropriate values for each of them use the UPIDOWN button. Figure 4-4: The Ext DC menu Menu name Time Test parameters M-P0X0AD-200-EN 1.800.561.8187 www. 13 .com information@itm.com POB-AD series Testing Using POB-AD 5 Testing using the POB-AD 5.1 Spring-charging Motor Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Before the test can be started, a test voltage needs to be defined using the Volt DC or Volt 50Hz/Volt 60Hz menu (Figure 4-1 or 4-2). Motor voltage can be selected in the range from 10 V to 250 V DC. Press the MOTOR button to start a test. The output DC voltage is generated supplying the motor at the pre-selected value, and the POB-AD displays the MOTOR menu. During the test, LED M flashes and the display shows voltage and current values as well as the test duration time. Figure 5-1: The MOTOR menu during the test Once the test is finished (the test current drops to zero), the POB-AD shows the Result menu. Figure 5-2: The Result menu The display shows the DC voltage value reached, maximum current (not the starting peak current) and test duration time. LED M is switched off. After 5 sec time delay the POB-AD automatically changes the display from the Result to the Volt DC or Volt 50Hz/Volt 60Hz menu display (depending on the menu being used). To stop the test at will, press the STOP button at any time during the test. The POB-AD goes into the Result menu, indicating a DC voltage value reached, maximum current (but not the starting peak current) and test duration time. LED M is off. 1.800.561.8187 M-P0X0AD-200-EN www. 14 .com information@itm.com POB-AD series Testing Using POB-AD 5.1.1 Important notes while testing with the POB-AD Note: For XXX seconds the POB-AD generates the predefined voltage value on the Motor outputs. After successfully exceeding 500 mA the POB-AD treats the test as successfully performed and displays the voltage and current values reached at the end as well as duration time of the test. These values will be presented on the display for 6 seconds and after that the display reverts to the previous menu. In case the level of 500 mA has not been reached, the POB-AD treats the test as unsuccessful, the POB-AD shows no results on its display and the test has to be repeated. In case the motor charging process has been interrupted (e.g. loss of a connection or other reason) the POB-AD will present the last recorded voltage value and test duration time for 6 seconds and after that revert to the previous menu. The test has to be repeated. Note: If the COIL button has been pressed while the POB-AD is generating the voltage on the motor outputs (no current is present on the MOTOR outputs), the POB-AD will switch off the motor outputs and start to generate predefined voltage on the COIL outputs (breaking and closing). The COIL menu will be displayed (Figure 5-3) indicating the voltage value. To stop the test at will, press the STOP button at any time during the test. Note: If any of the TRIG buttons have been pressed on the breaking/closing outputs, while the POB-AD is generating a predefined voltage on the motor outputs (no current is present on MOTOR outputs), the POBAD will switch off the motor outputs and generate a predefined voltage impulse lasting 140 ms on the corresponding COIL outputs (breaking or closing). The COIL menu will be displayed (Figure 5-3) indicating the voltage value. After the voltage impulse is generated, the POB-AD will continue generating voltage on the motor outputs. To stop the test at any time, press the STOP button. 5.2 DC Coils Testing The minimum trip voltage test of the circuit breaker’s coils can be performed manually or automatically. 5.2.1 Manual test Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Before a test can start please define the test voltages using the Volt DC menu (Figure 4-1) as described in the Section 4.1. By pushing the TRIG button on the breaking/closing outputs, pre-selected DC voltage lasting 140 ms is brought to a desired coil. During the test, the LED C flashes, the POB-AD displays the COIL menu indicating the generated voltage value (Figure 5-3), and then returns to the Volt DC menu. 1.800.561.8187 M-P0X0AD-200-EN www. 15 .com information@itm.com POB-AD series Testing Using POB-AD Figure 5-3: The COIL menu during the DC test If the coil is actuated, the POB-AD displays the Result menu, showing activating voltage and maximal current achieved during the test (Figure 5-4). Figure 5-4: The Result menu after the DC test If the coil failed to actuate, please select the higher value for the voltage in the Volt DC menu (Figure 4-1) and repeat this operation. The test can be aborted at any time by pressing the STOP button. In that case the POB-AD displays the Volt DC menu and LED C is turned off. The POB-AD can also be used as a source of continuous DC voltage. This option is available when using the POB-AD as a standalone device or in a combination with other test devices (DV Power or other manufacturer devices). The user defines the voltage value using the Volt DC menu as described in the Section 4.1. Use the LEFT/RIGHT buttons to move to the desired test voltage value. Use the UPIDOWN buttons to select the test voltages for coils. By pressing the COILS button, continuous pre-selected DC voltage is generated on the COIL outputs. The LED C flashes to indicate the DC voltage is generated. 5.2.2 Automatic test Turn on the POB-AD using the power switch on the back of the test set. The display presents the Volt DC menu; LED C and M are off. Pushing the ENTER button three times will bring the MTV DC menu (Figure 5-5). Figure 5-5: The MTV DC menu 1.800.561.8187 M-P0X0AD-200-EN www. 16 .com information@itm.com POB-AD series Testing Using POB-AD Using the LEFT/RIGHT buttons move the cursor to the position of the initial voltage (U min), maximal voltage (here 10,0 V and 40,0 V), and the voltage step (here 1,5 V). Using the UP/DOWN buttons please select their desired values. By pushing the TRIG button on the breaking/closing outputs the starting voltage is brought to the selected coil for 140 ms (milliseconds), and the display switches to the COIL menu (Figure 5-3). If the coil was not actuated, after 900 ms delay, the voltage increases automatically for the selected voltage step and the voltage is generated again (duration of 140 ms). The test can have two possible outcomes: a. The coil is actuated, when the POB-AD displays the Result menu, showing the activating voltage and maximal current (Figure 5-4), After 10 seconds the POB-AD returns to the MTV DC menu. b. The maximal test voltage was reached without coil actuation. "No activation“ error message will be displayed, LEDs M and C are ON continually, and the alarm beeps. To stop the test press the STOP button at any time during the test. The POB-AD switches to the MTV DC menu (Figure 5-5) and LED C is off. Note: There is an auxiliary (AUX) contact in the breaker circuit, which intersects the circuit protecting the coil. This way the POB-AD device detects the moment when the current drops to and the voltage at that instant of time is defined as the lowest coil activation voltage. 5.3 AC Coils Testing 5.3.1 Manual test Turn on POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Before a test can be started, please select the test voltages as per the Section 4.1 using the Volt 50Hz/Volt 60Hz menu (Figure 4-2). By pushing the TRIG button on the breaking/closing outputs, a pre-selected AC voltage lasting 140 ms is brought to a desired coil. During the test, the LED C flashes, the POB-AD displays the COIL menu showing a voltage value and the test duration time (Figure 5-6). Figure 5-6: The COIL menu during the AC manual test 1.800.561.8187 M-P0X0AD-200-EN www. 17 .com information@itm.com POB-AD series Testing Using POB-AD If the coil is actuated, the POB-AD displays the Result menu, showing the activating voltage and test current (Figure 5-7). Figure 5-7: The Result menu after the AC manual test If the coil failed to actuate, increase the voltage in the Volt 50Hz/Volt 60Hz menu (Figure 4-2) and repeat this operation. To stop the test press the STOP button at any time during the test. The POB-AD displays revert to the Volt 50Hz/Volt 60Hz menu and LED C is turned off. The POB-AD can also be used as a source of continuous AC voltage. Define the voltage value using the Volt 50Hz/Volt 60Hz menu (see the Section 4.1). Use the LEFT/RIGHT buttons to move to the test voltage position. Use the UPIDOWN buttons for coils. By pressing the COILS button a continuous pre-selected AC voltage is generated on the COIL outputs. The LED C flashes to indicate AC voltage is being generated. 1.800.561.8187 M-P0X0AD-200-EN www. 18 .com information@itm.com POB-AD series Testing Using POB-AD 5.4 Using the POB-AD with a Circuit Breaker Analyzer In case a Circuit Breaker Analyzer is being used for testing, the POB-AD is used as a power supply unit. Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Depending on the DC or AC coils please define the test voltages as shown in the Figures 4-1 or 4-2 (Section 4.1). Connect the POB-AD to a Circuit Breaker Analyzer using the originally provided external cable. The cable should be connected to the device as shown in the Figure 5-8. Figure 5-8: The External connector Figure 5-9: The External Trigger Cable 1.800.561.8187 M-P0X0AD-200-EN www. 19 .com information@itm.com POB-AD series Testing Using POB-AD By pressing the MOTOR button, the breaker spring is charged, and afterwards by pressing the button COILS a pre-selected voltage is generated on the coils outputs. LED C flashes. The coils are triggered from the Circuit Breaker Analyzer (Signal delay < 1 ms) using one of the two possible modes: 1. Contact mode: 2. Voltage mode: Open circuit voltage (Imax= 10 mA) In the range from 0 V to 50 V DC - Low activation mode – LOW - High activation mode – HIGH (ULmax= 1,5 V) (UHmin= 15 V) Note: - Positive (+) pole of the closing coil control output is connected to the yellow wire, - Negative (-) pole of the closing coil control output is connected to the white wire, - Positive (+) pole of the breaking coil control output is connected to the brown wire, - Negative (-) pole of the breaking coil control output is connected to the green wire. (please see the Figures 5-8 or 5-9) When the POB-AD is working together with a Circuit Breaker Analyzer, the test execution is controlled by the Circuit Breaker Analyzer . In this combination, the POB-AD serves as a power supply. All the time the signal from the Circuit Breaker Analyzer is active the voltage is generated on the coil outputs of the POB-AD device. Voltage at coil outputs can be interrupted at any moment by pushing the STOP button. 5.4.1 Using the External connector The POB-ADL can be remotely operated using the External Connector. Procedure: Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Before a test can be started, please define the test voltages as described in the Section 4.1 (Figure 4-1). Connect the External connector to the POB-AD. Use the originally supplied cable only. The External connector can work in the two possible modes: 1- Contact mode 2- Voltage mode The External Connector can be considered as the two sets of remote contacts; closing and breaking, as it is shown in the figure below: Figure 5-10: Contacts of the External connector Contacts can either be in CLOSE or in OPEN position. 1.800.561.8187 M-P0X0AD-200-EN www. 20 .com information@itm.com POB-AD series Testing Using POB-AD The CLOSE position means the contacts are short circuited at the External connector, or voltage is below 1.5 V. The OPEN position means the contacts are open at the External connector, or that voltage is above 15 V. Procedure to generate a voltage at the coils is the following: 1- Press the COILS button 2- Initiating the closing/breaking operation from the Circuit Breaker Analyzer, the selected voltage value is generated on the corresponding COIL output. Its duration is the same as the control signal from the breaker analyzer (breaking or closing). 3- When the test on the Circuit Breaker Analyzer ends, the control signal (OPEN position) is forwarded to the POB-ADL over the External Connector, and the voltage value at desired COILS output is set to 0 V. During the test, the LED C flashes, and the POB-shows the currently generated voltage value in the COIL menu on its display (Figure 5-3 or 5-6). To stop the test, please push the STOP button at any time during the test. The POB-AD returns to the Volt DC menu and the LED C is turned off. 5.4.2 Using the EXT DC menu The Ext DC menu is used for setting up the coils and spring-charging motor test voltage values on the POBAD when using the External Connector. The External Connector is used to bring the triggering signal from another device (usually a Circuit Breaker Analyzer) to POB-AD. The connection is provided using the External Trigger Cable. Turn on the POB-AD using the power switch on the back of the test set. The display shows the Volt DC menu; LEDs C and M are off. Using the UP/DOWN and LEFT/RIGHT buttons (or by pushing the ENTER button few times) select the EXT DC menu (Figure 5-11). Using the UP/DOWN and LEFT/RIGHT buttons select the desired test voltage value. Figure 5-11: The EXT DC menu The POB-AD can be operated from a distance using the External Connector. The procedure of generating a voltage at the coils is: 1- Ensure both contacts at the External connector are open (OPEN position) 2- Press the COILS button 3- By closing one (breaking or closing) contact (CLOSE position), the selected voltage is generated at the corresponding COIL with a duration of 700 milliseconds. 4- There are two contacts on the External Connector (Breaking i Closing). Each of them can be in an open or close position. That creates four possible combinations (Open-Open, Close-Close, Open-Close, i CloseOpen). For each of these combinations the POB-AD generates a selected voltage value on the appropriate 1.800.561.8187 M-P0X0AD-200-EN www. 21 .com information@itm.com POB-AD series Testing Using POB-AD COIL output. By opening the External Connector contacts (OPEN position) the voltage value at the desired COILS output is set to 0 V. During the test execution, the LED C flashes and the POB-AD is in the EXT DC menu. The generated voltage values are being presented on the device display. Note: The voltage generated at the COILS output is applied from the moment of closing the contacts till the opening moment but no longer than 700 milliseconds. 5.5 Duty Cycles During the test, the POB-AD generates a high current that heats up the test set. To prevent overheating of the POB-AD, certain duty cycles apply depending on the test voltage and current being deployed. The POB-AD is a powerful and versatile unit with the possibility to generate an initial current of 30 A (POB30AD) and 40 A (POB40AD) at 230 V mains supply as well as the continuous current according to the tables below: Model Mains Load Voltage Voltage 24 A 20 A 10 A 20 sec 60 sec contin. 110 V DC 30 A 24 A 12 A 20 sec 60 sec contin. 220 V DC 12 A 10 A 7A 20 sec 60 sec contin. 220 V DC 15 A 12 A 8A 20 sec 60 sec contin. 110 V AC 10 A 5A 1 sec contin. 110 V AC 15 A 10 A 10 sec contin. 220 V AC 10 A 5A 1 sec contin. 220 V AC 12 A 6A 10 sec contin. 48 V DC 24 A 20 A 10 A 20 sec 60 sec contin. 48 V DC 30 A 24 A 12 A 20 sec 60 sec contin. 110 V DC 12 A 10 A 7A 20 sec 60 sec contin. 110 V DC 15 A 12 A 8A 20 sec 60 sec contin. 125 V DC 10,6 A 8,9 A 3,5 A 20 sec 60 sec contin 13,2 A 115 V DC 10,5 A 120 V 7A 220 V DC 7A 6A 5A 20 sec 60 sec contin. 220 V DC 8A 6A 5A 20 sec 60 sec contin. 110 V AC 10 A 5A 1 sec contin. 110 V AC 12 A 8A 10 sec contin. 220 V AC 10 A 5A 1 sec contin. 220 V AC 8A 5A 10 sec contin. POB30AD 120 V M-P0X0AD-200-EN Mains Load Max Max load Voltage Voltage Current interval Model 110 V DC 230 V 1.800.561.8187 Max Max load Current interval www. 230 V POB40AD 22 .com 20 sec 60 sec contin. information@itm.com POB-AD series Customer Service Packing the Instrument for Shipment 6 Error Messages Any operational error is indicated by a continual light on the C and M LEDs along an audio alarm. Furthermore, the display indicates an error status message. Press the STOP button to stop the alarm buzzer, remove the status message off the display and return to the Volt DC menu. 6.1 Error Message "Overcurrent" This message is displayed if the test current is too high. In this case reduce the test voltage and repeat the test. Figure 6-1: Error message "Overcurr" 6.2 Error Message “Overheat” This message is displayed when POB-AD’s operating temperature rises too high. The reason for this could be: - ambient temperature too high (refer to the Section 10), despite the duty cycle time control, too many high current tests were performed in a too short period of time. Figure 6-2: Error message "Overheat" New test cannot commence before the device has cooled down. In this case, wait for the test set to cool down and repeat the test. 6.3 Error Message “No activation” This message is displayed if the POB-AD reaches the maximum pre-selected voltage and the coil is not yet actuated during the automatic test of the coil. The reason for this could be: - maximum pre-selected voltage is not high enough for the coil activation, test cables between the coils and the instrument are not connected properly. 1.800.561.8187 M-P0X0AD-200-EN www. .com 23 information@itm.com POB-AD series Testing Using POB-AD Figure 6-3: Error message "No activation" Select a higher test voltage (the max pre-selected value) or verify cable connections. Repeat the test. 6.4 Error Message “Malfunction” If this message appears on the display, or if the POB-AD cannot be operated anymore, a serious internal error occurred. Figure 6-4: Error message "Malfunction" Please do not open the POB-AD by yourself. Contact IBEKO Power AB (refer to the Section ”Manufacturer Contact Information”). 1.800.561.8187 M-P0X0AD-200-EN www. .com 24 information@itm.com POB-AD series Testing Using POB-AD 7 Troubleshooting 7.1 Voltage test If the device is suspected of presenting inaccurate voltage values, the DC and AC voltage measurement check should be performed as described bellow. 7.1.1 DC voltage measurement check 1. Connect the DC voltmeter to the POB-AD Breaking or Closing Coil DC output, as shown in the Figure 7.1. 2. Choose voltage values on the device according to the Table 7.1, to cover all ranges. 3. To choose a Coil’s test, press COIL key on the device. 4. Compare each voltage value measured with DC voltmeter to the expected voltage value from the Table 7.1. In the case of major differencies please contact DV Power support team. 7.1.2 AC voltage measurement check 1. Connect the AC voltmeter to the POB-AD Breaking or Closing Coil AC output, as shown in the Figure 7.2. 2. In order to choose the AC menu, press the ENTER key on the device. 3. Choose voltage values on the device according to the Table 7.2, to cover all ranges and then press the COILS key on the device, to choose Coil's test. 4. Compare each voltage value measured with the AC voltmeter to the expected voltage value from Table 7.2. In case of major differencies please contact DV Power support team. 1.800.561.8187 M-P0X0AD-200-EN www. .com 25 information@itm.com POB-AD series Testing Using POB-AD Figure 7.1 – DC voltage test connection Voltage on the device [V] 24 48 72 110 150 200 230 260 Figure 7.2 – AC voltage test connection Expected voltage value [V] 23,69 – 24,31 47,63 – 48,37 71,57 – 72,43 109,1 – 110,9 149 – 151 198,85 – 201,15 228.75 – 231.25 258.7 – 261.3 Voltage on the device [V] 24 48 72 110 150 200 230 250 Table 7.1 – DC voltage measurement check Expected voltage value [V] 23,69 – 24,31 47,63 – 48,37 71,57 – 72,43 109,1 – 110,9 149 – 151 198,85 – 201,15 228,75 – 231,25 248,7 – 251,3 Table 7.2 – AC voltage measurement check 7.2 Current test If the device is suspected of presenting inaccurate current meaurement values, the current measurement check described bellow should be performed. Connect the POB-AD, DC voltmeter, 5 Ω load and 10 mΩ test shunt, as presented in the Figure 7.3. Choose voltage values on the device according to the Table 7.3. To choose the Spring Charging Motor test, press the MOTOR key on the device. Measure the voltage drop on the test shunt Rshunt using a DC voltmeter. 5. Compare the current value displayed on the device and the measured voltage drop on the test shunt with the expected values in the Table 7.3. In case of major differencies please contact DV Power support team. 1. 2. 3. 4. 1.800.561.8187 M-P0X0AD-200-EN www. .com 26 information@itm.com POB-AD series Testing Using POB-AD Figure 7.3 – Current test connection Rload [Ω] Rshunt [Ω] Voltage on the device [V] Current value on the device [A] 5 5 10m 10m 20 40 3,96 – 4,04 7,95 – 8,05 Measured voltage drop on the test shunt Vshunt [mV] 39,6 – 40,4 79,5 – 80,5 Power through the load [W] 80 320 Table 7.3 NOTE: Please pay attention to the maximum power allowed through the load. Maximal power through the load is 320 W, when the voltage on the POB30AD device is 30 V (POB40AD device is 40 V). If there is no available load that can handle that power, please do not perform this test. 1.800.561.8187 M-P0X0AD-200-EN www. .com 27 information@itm.com POB-AD series Testing Using POB-AD 8 Customer Service Before calling or sending an e-mail to the Customer Service for assistance, please perform the following steps: 1. 2. 3. 4. Check all cable connections. Try to perform the test with another instrument, if available. Perform the troubleshoot procedure as described above. Provide the following information: • Instrument serial number, hardware configuration description, and software version • Comprehensive description of the problem, including information about the test object characteristic, error messages and the sequence of events before it appeared • List of solutions that have been tried The Customer Support Department can be reached at: Local support (Sweden): +46 8 731 78 24 International support: +46 70 0925 000 E-mail: support@dv-power.com Note: Email communication is preferred for support issues, since the case is then documented and traceable. Also, the time zone problems and issues with occupied telephones do not occur. 9 Packing the Instrument for Shipment If the instrument needs to be shipped to DV Power for servicing, please contact the DV Power Customer Service at: Local support (Sweden): +46 8 731 78 24 International support: +46 70 0925 000 E-mail: support@dv-power.com Note: DV Power is not responsible for any damage during shipping. Please protect each instrument from shipping and handling hazards carefully. Please ensure that the protective covers are securely in place. Instruments should be sent to DV Power freight pre-paid, unless other arrangements have been preauthorized by the DV Power Customer Service. To prepare the instrument for shipment, please follow these instructions: 1. Disconnect and remove all external cables. Do not include manuals, cables, and transducer connecting rods unless instructed by the DV Power Customer Service. 2. Reuse the original packing material if available. If it is not available, pack the instrument for shipment according to the instructions for fragile electronic equipment. It is recommended to use a two-wall minimum corrugated cardboard box with a minimum 5 cm (2 inch) thick poly foam padding, or a wooden crate with minimum of 5 cm (2 inch) thick poly foam padding all around. 1.800.561.8187 M-P0X0AD-200-EN www. .com 28 information@itm.com POB-AD series Technical Data 10 Technical Data 10.1 Mains Power Supply - Connection - Voltage single phase - Frequency according to IEC/EN60320-1; UL498, CSA 22.2 96 V – 264 V AC, +10% – -15% 50 Hz 10.2 Output data POB30AD POB40AD Max DC Current 30 A 40 A Max AC Current 12 A 15 A Output DC Voltage 10 V - 300 V 10 V - 300 V Output AC Voltage 10 V - 250 V 10 V - 250 V 10.3 Measurement 1 V – 300 V DC or 10 V – 250 V AC 1 A – 50 A ± (0,25 % rdg + 0,25 % F.S.) - Voltage - Current - Accuracy 10.4 Environmental conditions o - Operating temperature - Storage temperature - Humidity o o o -10 C - +50 C / 14 F - +122 F o o o o -25 C - +70 C / -13 F - +158 F 5% – 95% relative humidity, non-condensing 10.5 Dimensions and Weight - Dimensions 205 mm x 287 mm x 480 mm (W x H x D) without handle 8 in x 11.3 in x 18.9 in 10,6 kg / 22.5 lbs - Weight 10.6 Safety Standards - European standards LVD 2006/95/EC EN 61010-1 - International standards IEC 61010-1 UL 61010-1 CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment 1 10.7 Electromagnetic Compatibility (EMC) - CE conformity - Emission - Immunity 1.800.561.8187 M-P0X0AD-200-EN EMC directive 2004/108/EC EN 61326-1 EN 61326-1 www. .com 29 information@itm.com POB-AD series Accessories 11 Accessories Accessories Article number Mains power cable Ground cable Cable set 6 x 2 m, 2,5 mm2 Cable set 6 x 5 m, 2,5 mm2 Extern trigger cable 2 m Device bag Cable bag Transport case C6-02-02BPBP C6-05-02BPBP TC-02-04MCBP DEVIC-BAG-00 CABLE-BAG-01 HARD-CASE-P0 IBEKO Power AB 2014 This Manual is a publication of IBEKO Power AB, 181 50 Lidingö, Sweden. These documents are protected by Swedish Copyright law and international contracts as intellectual property of the IBEKO Power AB. The documents contain confidential information of IBEKO Power AB which is protected by patent, copyright, trademarks or otherwise as inventions, trademarks or creations of IBEKO Power AB. The reproduction, duplication, transmission or use of these documents or its contents is not permitted without express prior written consent of the IBEKO Power AB. IBEKO Power AB shall not be liable for any incidental or consequential damages resulting from the performance or use of this document or its product. This document has undergone extensive technical approval before being released. IBEKO Power AB reviews this document at regular intervals, and includes appropriate amendments in subsequent issues. While every effort has been made to keep the information herein as accurate and up to date as possible, IBEKO Power AB assumes no responsibility for errors or omissions or for damages resulting from the use of the information contained herein. IBEKO Power AB cannot take over liability resulting in any way from the use of this document or parts thereof. The product information, pictures, drawings and all technical data contained within this manual are not contractually binding and IBEKO Power AB reserves the right to make modifications at any time to the technology and/or configuration without prior notice. Insofar as any information, software or documentation is made available, any liability for defects as to quality or title of the information, software and documentation especially in relation to the correctness or absence of defects or the absence of claims or third party rights or in relation to completeness and/or fitness for purpose are excluded except for cases involving willful misconduct or fraud. In case of a disagreement between the translation and the original English version of this Manual, the original English version will prevail. 1.800.561.8187 M-P0X0AD-200-EN www. .com 30 information@itm.com POB-ADL Manufacturer Contact Information data Manufacturer Contact Information IBEKO POWER AB Box 1346, 181 25 Lidingö, Sweden Local support (Sweden) tel: +46 8 731 78 24 International support tel: +46 70 0925 000 Fax: + 46 8 731 77 99 E-Mail: support@dv-power.com Website: http://www.dv-power.com 1.800.561.8187 M-T063NN-205-EN www. .com 31 information@itm.com