38AE,AK,AKS, 48DR,DRE 48/50DP,DPE Accessory Packages Installation Instructions Accessory Winter Start Package (Time-Delay Relay) 38AE900021 Accessory Relay-Transformer Package 38AE900001 SAFETY CONSIDERATIONS Installation, start-up and servicing of this equipment can be hazardous due to system pressures, electrical components, moving parts, and equipment location (roof, elevated structures, etc.). Only trained, qualified installers and service mechanics should install, start up, and service this equipment. Untrained personnel can perform such basic maintenance functions as cleaning coils or replacing air filters. All other operations should be performed by trained service personnel only. When working on equipment, observe precautions in literature; tags, stickers, and labels attached to equipment; and any other safety precautions that apply. • Follow all safety codes. • Wear safety glasses and work gloves. • Use care in handling, rigging, and setting bulky equipment. Before performing service or maintenance operations on unit, turn off main power switch to unit. Electrical shock could cause personal injury. GENERAL Accessory Winter Start Package 38AE900021 provides a 3-minute time delay for the low-pressure switch (LPS). The relay HN67XZ210 is a normally-closed relay. Accessory Relay-Transformer Package 38AE900001 allows installation of multiple liquid line solenoids and other larger 24-v relay loads. See Table 1 for package numbers. Table 1 — Usage Table UNIT ACCESSORY WINTER START PACKAGE 38AE012,014,016 38AK007,008,012 38AKS008,009 48DP/DR016,020 48DPE/DRE014 50DP016,020 50DPE014 38AE900021 ACCESSORY RELAY — TRANSFORMER PACKAGE 38AE900001 — Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 1 4 4 4 PC 111 Catalog No. 563-983 Printed in U.S.A. Form 38/48/50-1SI Pg 1 3-93 Replaces: 38AE-12SI Tab 1a 1b 3a 2a 6a 6b INSTALLATION (TDR), Winter Start Package 38AE900021 in 38AE012016, 38AK007-012, or 38AKS008,009 condensing units as follows: 1. See Fig. 1 for location of component in 38AE012, 014, or 016. See Fig. 3 for location of component in 38AK007012 or 38AKS008,009. Use field-supplied screws and be certain mounting holes are positioned upwards (Fig. 4), as device is position sensitive. 2. Run field-supplied wires from quick-connect terminals in device to 38AE unit controls as shown in Fig. 5. Run field-supplied wires from quick-connect terminals in device to 38AK,AKS unit controls as shown in Fig. 6. Relay-Transformer Package — Unit 38AE — Refer to unit label diagram and install Relay-Transformer Package 38AE900001 in 38AE012, 014, or 016 condensing unit as follows: 1. See Fig. 1. Locate component below terminal block 2 (TB2) in unit control box. A knockout is provided in the bottom of the control box for running wires from the accessory to TB2. Using the bushing nut (coupler) provided, route the 6 wires through the knockout and tighten the bushing nut. Secure side of accessory to condensing unit using 2 screws provided. 2. Connect wires to 38AE controls as shown in Fig. 2. Winter Start Package — Units 38AE,AK,AKS — Refer to unit label diagram and install time-delay relay LOCATE WINTER START PACKAGE HERE RELAY-TRANSFORMER PACKAGE (SHOWN INSTALLED) Split System Fig. 1 — Recommended Locations for Accessory Components in 38AE Units 2 LEGEND C CM HD HT ANT. IFC IFR LLS R RC RH SVR TB TC TH TRAN — — — — — — — — — — — — — — — Compressor Contactor Common Heat Device Heat Anticipator Indoor-Fan Contactor Indoor-Fan Relay Liquid Line Solenoid Accessory Relay (Field Supplied) Relay, Cooling Relay, Heating Solenoid Valve Relay Terminal Block Thermostat Cooling Thermostat Heating Transformer Field-Supplied Wiring *Wires factory supplied, field connected. Fig. 2 — Accessory Relay-Transformer 38AE900001 Wiring 3 LOCATE WINTER START PACKAGE HERE Fig. 3 — Recommended Location for Accessory Component in 38AK,AKS Units Fig. 4 — Top View, Winter Start Package LEGEND C HPS IP LPS TDR — — — — — Contactor High-Pressure Switch Internal Protector Low-Pressure Switch Time-Delay Relay Field-Supplied Wiring Fig. 5 — Connection Points, Time-Delay Relay, Accessory Winter Start Package 38AE900021; 38AE Condensing Units 4 C CLO HPS LPS — — — — Contactor Compressor Lock Out High-Pressure Switch Low-Pressure Switch LEGEND TDR — Time-Delay Relay Factory-Supplied Wiring Field-Supplied Wiring Fig. 6 — Connection Points, Time-Delay Relay, Accessory Winter Start Package 38AE900021; 38AK,AKS Condensing Units TIME DELAY RELAY (TDR) LOCATION IFC KO KO 7/8" SNAP BUSHING TRANSFORMER LOCATION Winter Start Package — Units 48DP/DPE, 48DR/DRE, 50DP/DPE — Refer to unit label diagram and install time-delay relay (TDR) Winter Start Package 38AE900021 in 48DP/DR016,020; 48DPE/DRE014; 50DP016,020; or 50DPE014 unit as follows: 1. See Fig. 7. Locate the time-delay relay in the area shown in the control box, using field-supplied screws and ensuring that the top terminals are up, as device is position sensitive (Fig. 4). 2. Run field-supplied wires from quick-connect terminals in the device to the unit as shown in Fig. 8. LEGEND IFC — Indoor-Fan Contactor KO — Knockout Fig. 7 — Typical Main Control Box for 48/50DP,DR Units 5 LEGEND C CLO FPT HPS — — — — Contactor Compressor Lock Out Freeze Protection Thermostat High-Pressure Switch LPS TDR — Low-Pressure Switch — Time-Delay Relay Factory-Supplied Wiring Field-Supplied Wiring Fig. 8 — Connection Points, Time-Delay Relay, Winter Start Package 38AE900021; 48DP/DPE, 48DR/DRE, 50DP/DPE Units 6 Copyright 1993 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 1 4 4 4 PC 111 Catalog No. 563-983 Printed in U.S.A. Form 38/48/50-1SI Pg 8 3-93 Replaces: 38AE-12SI Tab 1a 1b 3a 2a 6a 6b