Cube3 Ultra 0.13 gpf (0.5 lpf) Electronic Activation Urinal

advertisement
CI/SfB
Date
(74.1)
g3
August 2009
Supersedes all previous issues
Cube3 Ultra 0.13 gpf (0.5 lpf)
Electronic Activation Urinal Suite
9.1
Smart Demand ‘Urine Sensing’ Flushing System
With Vitreous China Wall-Hung Box Rim Urinal
c -UPC
IAPMO listed for USA & Canada
Cube3 Ultra
0.13 gpf (0.5 l)
HEU
Smart Demand ‘Urine Sensing’ Flushing System
Inwall/Induct/Inceiling
With Vitreous China Wall-Hung Box Rim Urinal
A contemporary design fully integrated box rim, wall mounted urinal operating with a ultra low flush of 0.13
gpf (0.5 liter). The system incorporates a fully automatic electronic smart demand ‘Urine Sensing’ urinal suite
featuring hands-free operation to give a combination of superior features in optimum user hygiene, water
saving and vandal resistance. Cube3 Ultra combines the new smart demand flushing system with the Cube3
Ultra urinal ensuring optimal operational standards and efficiency. The sensor is concealed behind the urinal
resulting in vandal resistant installation ideal for heavy-duty applications. The sensor device is factory fitted
for ease of installation.
Inlet:
Outlet:
Inwall:
Induct:
Inceiling:
Electronic
Urinal Suite:
Flush Control
Mechanism:
Back inlet for concealed nominal 3/4" (20mm) diameter (stubbed down to 1/2"/12.7mm
inlet) sparge pipe and compression rubber fitting.
The urinal trap is connected to wall waste pipe which allows for a simple push on urinal
connection.
Automatic urinal flush system suitable for minimum cavity thickness of 4"(100mm).
Automatic urinal flush system.
Automatic urinal flush system.
Wall mounted urinal suite Code No. 678650. Electronics Code No. 687278.
135/8" (345mm)
Smart demand ‘Urine Sensing’ operation with an integrated smart logic system, detects
user and determines flush mode accordingly. The flush duration is adjustable to allow for
the accurate determination of flush volume at varying pressures.
Stadium operation: 5 or more uses within a time period of three minutes =
1 flush/minute. Automatically reverts to normal usage at non-peak periods.
Hygienic Flush: Hygienic flush every 24 hours prevents the trap seal from drying out.
Electronic Valve:The operating voltage of the valve is 6 volts. The operation flow pressure of the valve is
43.5 to 72.5 psi (300 to 500 kPa) 981/2' to 164' (30 to 50 metres head) with a minimum
flow to the valve of 5.3 gallons/minute (20 litres/minute). The valve incorporates an
integral airbreak system and shut off valve.
Supply voltage-transformer. Operating current 9 volts (6 x 1.5v AA batteries).
Battery
operated:
Provide conduit without kinks to connect the sensor cable to the control box. 3.5m of
Installation:
sensor cable supplied as standard. Minimum supply diameter of nominal 3/4" (20mm) is
required to the valve.
All dimensions are in inches and millimetres and are subject to normal manufacturing
Dimensions
variations. Caroma pursues policy of continued improvement in design and performance
of its products. The right is therefore reserved to vary specifications without notice.
White.
Color:
101/4" (260mm)
Inlet Centre
21/2" (65mm)
c -UPC
IAPMO listed for USA & Canada
* 24" (610mm) recommended standard height
17" (432mm) recommended disabled height
18" (458mm)
Finished Floor
Caroma International Pty Ltd. ABN 90 35 053 413 157
145/8" (371mm)
P-trap outlet centre
*
31/8"
(80mm)
263/8" (670mm)
241/4" (615mm) approx.
D.167 Concealed Fixing Bracket
Vitreous china grate
D.167 Concealed Fixing Bracket
(wall fixings not supplied)
Fixing
Stud
Plastic
Sleeve
Plastic
Cap
9 volt battery power supply unit
Sensor Control
1/2" BSP
5" (127mm)
43/8" (110mm)
33/4" (95mm)
Inceiling Installation
9 volt battery
power supply unit
SENSOR
COMPACT
HF Urinal
Integral
Airbreak
43/4" (121mm)
4" (103mm)
Shut off valve
Solenoid
Allow access for the
connection and
servicing of all
electrical components
3/4" BSP male
Inwall Installation
9 volt battery
power supply unit
Copper flush pipe
Nominal 3/4" (20mm)
Induct Installation
9 volt battery
power supply unit
Sensor
Control
Unit
Sensor cable
Important:
Install flexible electical
conduit pipe to protect
cable
19" (0.5m) min.
118" (3m) max.
Sensor Control Unit
Sensor cable
Copper flush pipe
Nominal 3/4" (20mm)
(stubbed to 1/2"/13mm
at inlet)
Sensor
Control
Unit
3/4” to 1/2” elbow
(20mm-13mm)
Sensor
31/8"
(80mm)
*
241/4" (615mm) approx.
D.167 Concealed Fixing Bracket
Sensor
Sensor
* 24" (610mm) recommended standard height
17" (432mm) recommended disabled height
Finished Floor
Finished Floor
Inlet Centre
21/2" (65mm)
1" (26mm)
18" (458mm)
Nominal 1/2" (13mm)
sparge brass pipe
(not supplied)
35
2° Slope
Kee Seal supplied
to suit PVC or ABS
DWV outlet connection
Caroma International Pty Ltd. ABN 90 35 053 413 157
145/8" (371mm)
P-trap outlet centre
2" (50mm) PVC DWV or
ABS DWV
Centre of Urinal
(20mm)
35/8" (92mm)
3/4"
2" (52mm)
11/2"
(40mm)
145/8" (371mm)
P-trap outlet centre
241/4" (615mm) approx.
D.167 Concealed Fixing Bracket
31/8"
(80mm)
Caroma International Pty Ltd. ABN 90 35 053 413 157
Plastic Waste trap