1074257_W2_B Rada Tripoint_F Mixer Tap.indd

advertisement
Tripoint-F
PRODUCT MANUAL
IMPORTANT
Installer: This Product Manual is the property of the
customer and must be retained with the product
for maintenance and operational purposes.
1
CONTENTS
DESCRIPTION .......................................................................................... 3
IMPORTANT SAFETY INFORMATION .................................................... 3
SPECIFICATIONS..................................................................................... 3
DIMENSIONS AND CHECKLIST ............................................................. 4
INSTALLATION......................................................................................... 5
Installation Options ............................................................................... 5
Operation.............................................................................................. 7
Setting the Rada Tripoint-F sensor tap for fixed temperature flow ....... 8
MAINTENANCE ........................................................................................ 9
Cleaning the Filters .............................................................................. 9
Changing the Flow Straightener / Aerator .......................................... 10
Cleaning ............................................................................................. 10
FAULT DIAGNOSIS ................................................................................ 10
SPARES .................................................................................................. 11
CUSTOMER CARE ................................................................................. 12
2
DESCRIPTION
The Rada Tripoint-F sensor deck mounted washbasin tap complies with all
relevant directives for CE marking. The Tripoint-F sensor tap can be installed as an
adjustable, a pre-set non-adjustable or for pre-mixed supply for most commercial
applications.
IMPORTANT SAFETY INFORMATION
Installations must comply with all Local/National Water Regulations/Bye-laws
(Scotland), Building and Plumbing Regulations.
Installation must be carried out in accordance with these instructions, and must be
conducted by designated, qualified and competent personnel.
Disinfectants: In applications where system chemical disinfection is practised,
chlorine can be used (calculated chlorine concentration of 50 mg/l [ppm] maximum
in water, per one hour dwell time), at service interval frequency. Such procedures
must be conducted strictly in accordance with the information supplied with the
disinfectant and with all relevant Guidelines/Approved Codes of Practice. If in any
doubt as to the suitability of chemical solutions, refer to Kohler Mira Limited, or your
Local Agent.
When the battery has reached the end of its serviceable life, make sure the battery
is disposed of in a safe manner, in accordance with current local authority recycling,
or waste disposal policy.
SPECIFICATIONS
Pressures
Maximum Static Pressure
Minimum Pressure Loss
Flow Rates and Times
Minimum Flow Rate (Flow Regulator Fitted)
Maximum Flow Period
Intelligent After Flow Period
Temperatures
Maximum Hot Water
Electrical
Power Supply
Sensor Recognition Range
Approvals
Noise Class
IP Rating (Protection Class)
3
1000 kPa (10 bar)
200 kPa (2 bar)
6 L/min (300 kPa (3 bar))
2 minutes ±3 seconds
3 seconds ± 2 seconds
70 °C
6 V lithium battery 2CR5
Optimal preset
I (ISO 3822)
IP67
DIMENSIONS AND CHECKLIST
; Tick the appropriate box after familiarising yourself with the tap and to confirm that all
the parts illustrated are included.
Note! All dimensions are nominal and in millimetres.
… 1 x Cleaning Cover
… 1 x Blanking Plug
… 1 x Temperature Plug Cover
… 2 x Wall Plugs
… 2 x Fixing Screws
… 2 x Cable Ties
… 1 x 2.5 mm Hexagonal Wrench
… 2 x 3/8’’ Adapters/Check valves
… 2 x Filters
… 2 x 3/8’’ - 1/2’’ Adapters
Documentation
… 1 x Product Manual
… 1 x Instruction Sticker
4
… 1 x Flow Straighter + Washer
INSTALLATION
Installation Options
Note! Do not install opposite a mirror.
Blanking plug
Adjustable
temperature outlet
Set for
fixed temperature outlet
1
2
Minimum Ø30 mm
Maximum Ø37 mm
5
Using pre-mixed
temperature supply
Note! Turn to full cold and
block hot inlet.
Warning! Inlets have left
hand threads.
3
4
6
5
This completes the fitting of the Rada Tripoint-F sensor tap.
Operation
Operate the tap and rotate the lever to adjust the water to your required
temperature.
7
Setting the Rada Tripoint-F sensor tap for fixed temperature flow
Operate the tap until the temperature of the water flow is stable and follow steps
1 to 4 to set the fixed water temperature.
1
1
2
3
4
Operate the tap and check the water temperature is correctly set.
8
MAINTENANCE
Note! Isolate the water supplies and operate the tap to release pressure and to assist
the draining of residual water before any maintenance is carried out.
Cleaning the Filters
1
2
3
9
Changing the Flow Straightener / Aerator
Cleaning
The tap should ONLY be cleaned using a mild washing up detergent or soap solution
and wiped dry with a soft cloth.
Note! To isolate the sensor, place cleaning cover over the sensor.
Cleaning Cover
FAULT DIAGNOSIS
Symptom
Cause / Rectification
Continuous flow from the tap
Solenoid valve damaged / Replace
Reduced flow from the tap
Blocked filter or aerator / Refer to ‘Maintenance’
section
No flow from the tap
Check the water supply and rectify
The sensor is covered, dirty, disconnected or
damaged / Clean, check the connections or
replace the sensor
The solenoid valve is damaged / Replace the
solenoid valve
The battery is flat / Replace the battery
10
SPARES
1658.012
1658.013
1658.014
1658.016
1658.017
1658.018
1658.019
1658.020
1658.021
1658.022
1658.023
1658.025
1658.026
1658.027
Filter
Sensor
Aerator M24
Mixing Plug
Membrane
Solenoid Valve (complete)
Battery (complete unit)
Battery
Temperature Control Handle
Inlet Hose
Product Manual
3/8” Adaptor Check Valve and 3/8” to 1/2” Adaptor
Flow Straightener M24 x 1
Cleaning Cover
1658.014
1658.026
1658.027
1658.013
1658.018
1658.017
1658.021
1658.016
1658.022
1658.019
1658.020
1658.012
1658.025
11
CUSTOMER CARE
Guarantee of Quality
Kohler Mira Ltd. guarantee this product against any defect in materials or workmanship for the period of five
years from the date of purchase, covering all parts, labour for the first year and replacement parts only for the
next four years.
To be covered by this guarantee, service work must only be undertaken by Kohler Mira Ltd. or by their approved
agents. Service labour will be free of charge for the first year and chargeable at prevailing rates for the next four
years.
Not covered by this guarantee
Damage or defects arising from incorrect installation, improper use or failure to maintain in accordance with the
instructions in this product manual, including the build-up of limescale. Defects or damage if the product is taken
apart, repaired or modified by a person not authorised by Kohler Mira Limited or by their approved agents.
After Sales Service - how we can help you
We have a network of fully trained staff ready to provide assistance, should you experience any difficulty
operating your Rada equipment.
Spare Parts
All functional parts of Rada products are kept for up to ten years from the date of final manufacture. If during that
period, our stock of a particular part is exhausted we will, as an alternative, provide an equivalent new product
or part at a price equating to the cost of repair to the old, bearing in mind the age of the product.
All spares are guaranteed for 12 months from date of purchase. Spares that have been supplied directly from
us can be returned within one month from date of purchase, providing that they are in good order and the
packaging is unopened.
Note! Returned spares will be subject to a 15% restocking charge and authorisation must be obtained before
returning any spare part.
Customer Care Policy
If within a short space of time of installation the product does not function correctly, first check with the operation
and maintenance advice provided in this Product Manual to see if the difficulty can be overcome. Failing this,
contact your installer to make sure that the product has been installed and commissioned in full accord with our
detailed installation instructions. If this does not resolve the difficulty, please ring your nearest Rada contact,
who will give you every assistance and if appropriate, arrange for your local service engineer or agent to call
on a mutually agreeable date.
Contact:
For the latest information on Rada sense, visit www.radasense.com
Rada Controls
C r o m w e l l R o a d , C h e l t e n h a m , G L 5 2 5 E P,
SPECIFICATION ENQUIRIES
England, UK
Telephone: +44 (0)1242 282527
Telephone: +44 (0)870 600 0221
Fax:
+44 (0)1242 282404
Fax:
+44 (0)1242 221925
E-mail:
rada_technical@mirashowers.com
Rada is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specifications without notice.
www.radacontrols.com
943010-09-07
1074257_W2_B (K74F)
12
© Kohler Mira Limited, January 2008
Download