102003 GE Industrial Solutions GE Energy Industrial Solutions Industrial Solutions (formerly Power Protection), a division of GE Energy, is a first class European supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. @ EntelliGuard™ - Power Circuit Breaker www.ge.com/uk/industrialsolutions www.ge.com/ex/industrialsolutions Ed. 02 GE Energy Industrial Solutions Ltd Houghton Centre Salthouse Road Blackmills Northampton NN4 7EX United Kingdom Customer Service UK Tel. 0800 587 1239 Fax 0800 587 1251 e-mail: order.consind@ge.com General Electric International, Inc 1101, City Tower 2, Sheikh Zayed Road P.O. Box 11549, Dubai United Arab Emirates Tel. +9714 313 1202 GE Energy Industrial Solutions New ™ EntelliGuard Power Circuit Breaker Uncompromising, Fast & Selective Customer Service MEA Tel. +361 447 6046 Fax +361 447 5060 e-mail: mea.export .consind@ge.com GE imagination at work GE imagination at work 680867 Ref. I/3288/G/G 3.0 Ed. 09/11 © Copyright GE Industrial Solutions 2011 Ed. 02 EntelliGuard™ 2 Product Identification 3 Features 9 Total Solution 10 Performance Ratings The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X 1 EntelliGuard™ Product Identification Power Circuit Breaker Front Facia 1 2 3 Power Circuit Breaker 4 5 6 7 8 9 10 ➊ Installed Accessory Indicators Electronic Trip Unit Manual Charging Handle ON and OFF Buttons Contact Position Indicatior Ready to Close Indicator Spring charged Indicator Operation Counter Prevision for Key Lock Global Catalogue Number ➌ ➋ ➍ ➍ ➏ ➎ ➒ EntelliGuard™ GG20H1XXGXXX2XX03 Intro ➑ ➐ ➓ Power Circuit Breaker label 1 A 2 3 4 B 5 6 7 8 C Product Type Bar code with Manufacturing data Colour Code indicating Interruption Tier Voltage Ratings Current Ratings Certification & Standards Short-circuit Interruption data Manufacturing Date ➊ ➍ ➎ ➐ D SET UP E ➊ Advanced Electronic Trip Unit METER 1 STATUS F EVENTS ➌ X ➋ ➍ 2 3 4 2 Main Screen with the following choices: Setup Allows adjustment of values and setting of all Parameters Meter Full measurement values are displayed Status Breaker and Trip Unit position Events History of Trip’s with indication of fault reason and level and access to the Waveform Capture function Cursor driven setting system Manual or Automatic Reset Choice Full Range Rating Plug ➏ ➑ ➌ ➋ EntelliGuard™ Power Circuit breakers Uncompromising Fast & Selective Features Intro A B EntelliGuard™ Power Circuit Breakers are a new line of Air Circuit Breakers evolved from the existing M-PACT & ME07 types to offer a truly global product platform meeting IEC, ANSI and UL standards. A line of Three and Four pole devices ranging from 400 to 6400Amp in three basic envelopes with fault interruption ratings of up to 150kAmps. A design offering a unique combination of High Fault current withstand ratings, short fault interruption time and selectivity. The device includes the new state-of-the-art EntelliGuard™ trip unit that enables the circuit breaker with the latest technology for system safety, reliability, measurement, relaying and communications using the Modbus or Profibus protocol. C D Contents Hi-Performance Complete Line E Selective and Fast Uncompromising F State of the Art Protection The Global Trip Unit X Easy to use & Flexible Installation options Common, Field Mountable Accessories A Full Solution for Low Voltage Distribution Catalogue Content This catalogue only refers to the IEC versions of the EntelliGuard™ Power Circuit Breaker. For the ANSI and UL variants of the same design please contact GE Industrial Solutions Plainville CT U.S.A. 3 EntelliGuard™ Hi-Performance: Complete Line Hi-Performance: Complete Line Power Circuit Breaker The EntelliGuard™ range of Power Circuit breakers encompasses a line of Three and Four pole Air Circuit Breakers with Nominal Currents ranging from 400 to 6400Amp in three basic envelopes. All Power Circuit Breakers are designed to allow multiple interruptions of fault currents. Here the tested and certified Service Breaking capacity value is in all cases equal to the stated Ultimate Breaking Capacity. Envelope 1 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 400 to 2000Amps at 50°C. This type is available in interruption ratings (Ics=Icu) of 50 and 65kA. A version suitable for DC applications is available. Envelope 2 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 400 to 4000Amps at 50°C. This type is available in interruption ratings (Ics=Icu) of 50, 65, 85 and 100kA. A version suitable for DC applications is available. 150 150 140 140 130 130 120 120 110 110 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 00 Intro A B Available Interruption tiers Envelope 2000A lcu=lcs C S Envelope 3 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 3200 to 6400Amps at 50°C. This type is available in interruption ratings (Ics=Icu) of 100 and 150kA. A version suitable for DC applications is available. Envelope 4000A lcu=lcs N Envelope 6400A lcu=lcs L M H 8000 D Hi-Performance: Current Ratings in Enclosures 7000 6000 One of the most important user parameters is not the nominal rating of an ‘Air Circuit Breaker’ in free air but its current Rating within a panel or enclosure. 5000 E 4000 Current Stroom 3000 F 2000 1000 40°C 50°C 55°C 60°C 65°C Ambient temperature Omgevingstemperatuur Bouwgrootte Envelope 3 3 Bouwgrootte 2 dubbele Envelope 2, dual clustercluster Bouwgrootte 2 enkele cluster Envelope 2, single cluster Bouwgrootte Envelope 1 1 X 70°C Breakers ‘enclosed ratings’ are determined by the heat dissipation produced by the device and its ability to carry current at the temperature within the enclosure. EntelliGuard™ Power Circuit breakers have been designed with low Power dissipation values and allow relatively high currents at high ambient temperatures. This is applicable for breakers in the fixed and Draw-out Pattern as indicated in the graph insert. For extreme cases a special dual cluster draw-out version of an envelope 2 breaker is available allowing a very limited derating when the breaker is used at high ambient temperatures within an enclosure. Standard Draw-out Construction ‘Single Cluster’ 4 ‘Limited de-rating’ Draw-out Construction ‘Dual Cluster’ EntelliGuard™ Selective, Fast & Uncompromising EntelliGuard GT Electronic Trip Unit 10000 Time Current Curve Breaker In =2500A Ir =2160A LT - Device ST - Device I - Device HSIOC -Device 2h Selective & Fast 1000 EntelliGuard™ has been designed to offer an uncompromising combination of a fast interruption at high fault levels attaining values of 40 Milliseconds or less whilst maintaining selectivity. 1 100 Power Circuit Breakers are designed to remain closed on a fault. This for at a user settable time value when the fault level lies within the range of the Short Time Delayed protection device AND for 15 Milliseconds when the fault level attains the Instantaneous protection range value. 10 1 Tripping Time Seconds Tripping Time In In Seconds (s) (s) Speed WHEN needed ... Warrantied selectivity elsewhere The simplest, standard, Electronic Trip Unit, has a broad range of timed bands at all overcurrent levels. Thus attaining selectivity between closely rated devices and across multiple distribution levels. This strongly simplifies and economizes installation design. 2 0,1 0,01 3 Features This Instantaneous device includes programming that in normal circumstances waits until the downstream breaker trips. 4 The depicted curves only indicate the Full Clearing time 1000 10000 100000 Currentinin Amps Current Amps ] 1. 2. 3. 4. Intro Overload Protection (LT) with 44 bands Timed Short-circuit Protection (STD) with 17 bands Selective Instantaneous Protection (I) Hi-Speed trip (HSIOC) A Uncompromising ... Reliability B EntelliGuard™ has been designed as a Modern ‘Power Circuit Breaker’ without neglecting its and GE’s heritage of more than 50 years in building Air Circuit Breakers. C These Power Circuit Breakers uncompromisingly combine the properties of the older M-PACT 1 and 2, ME07 and Wavepro lines with modern state of the art technology. D The result: a device that with a proven Electrical and Mechanical life span independent of its operation mode. Be it manual, electrical or by means of the installed Shunt and/or Undervoltage releases. E F Uncompromising ... Safety STDB 17 timing options from 90 to 1000 milliseconds 0,1 X Iselective Trips within 50-60 milliseconds Seconds (s) In order to protect Service Personnel against the hazards of Short Circuits whilst working on a Power Distribution system EntelliGuard™ Power Circuit breakers can be equipped with a so called RELT switch input. This allows the breaker to be switched to its lowest Short-circuit settings on service, thus limiting the hazards concerned. IRELT Trips within 40-50 milliseconds The RELT switch input (with feedback) is available on the breaker auxiliary terminals or can be accessed through the communication bus. IHI Speed Trips within 40 milliseconds 0,01 1000 10000 100000 Amps 5 EntelliGuard™ Protection with State of the Art Trip Units State of the Art Electronic Trip Unit Power Circuit Breaker All EntelliGuard™ Power Circuit Breakers are equipped with a digital electronic trip unit, available in four basic versions: E, S, N and H. Each has a common design that comes with a screen providing an ammeter and allowing a simple and accurate menu-driven adjustment of the breaker parameters across a broad current range. All functionality is menu-driven accessed by using 4 setting and one enter key thus allowing a fast and accurate setting of the device. The user can set the device to an automatic or manual reset after a fault. After inserting the rating plug, the device can be adjusted and the installed options set. As this normally occurs when the installation is not powered up, the use of the separately available TESTER with Power Pack is advised. Main adjustment Options EntelliGuard GT Electronic Trip Unit 10000 LT-LTD protection Each device has an overload of settings or LT setting range of 0,2 to 1 times with a choice of more than 60 setting points. The Overload device has 44 time band settings allowing one to configure this device for almost any perceivable application. LT Protection 0.2 -1 x In Intro 1000 A 100 LTD 44 bands 10 ST-STD protection A time delayed Short-circuit protection is installed with an adjustment range of 2 to 12 times the set LT current values. The Short-circuit interruption time can be set, at one of 17 bands ranging from 90 Milliseconds to 1 second. ST Protection 2- 12 x Ir B STD 17 bands 1 I protection A switchable instantaneous protection can be optionally installed. This device is adjustable from 2 to 15 or 30 times the rating of the breaker and is programmed to wait for downstream devices to trip before reacting. With/Without I2T TrippingTime TimeInInSeconds Seconds Tripping (s)(s) C D E I Protection 2-15 x In 0,1 Other protection features A host of other protection devices as LT-B & LT-C, RELT, GF sum & GF source return plus the optional use of energy curves are available (see section B of this catalogue). 0,01 0,001 1000 10000 100000 x Current CurrentininAmps Amps ] F SET UP X METER SET UP VOLTAGE STATUS L1L2EVENTS L3- 6 REAL SET UP POWER PHA/L1 SET UP CURRENT 700kW PHA/L1PHB/L2APPR 350A SET UP POWER 300A PHB/L2PHA/L1 PHC/L3300A 750kVA 320A PHC/L3PHB/L2 320A 480kVA PHC/L3 220kVA Measurement, Relaying & Communication The EntelliGuard™ Trip Unit has been envisaged to provide the user with more. Optionally a full network measurement device can be installed on the device. Relays can be included to trip the breaker on Voltage Unbalance, Current Unbalance, Power reversal etc. The device can be equipped with Communication for use with the Modbus or Profibus protocol whilst events as Overload, Short-circuit and Groundfaults can be tracked. Optionally the user can portray a Shortcircuit event through the Wave Form Capture option. Plug ‘n Play Electronic Trip Units are normally supplied factory fitted. However spares are available that plug into the breaker, automatically read the main breaker data and adjust themselves automatically to the breaker type. This option can be used to allow Field replacement or Upgrades of existing Trip Units OR can allow the user to acquire Breakers in kit form and customize them locally. EntelliGuard™ Power Circuit Breakers Easy to Install & Versatile Stan Depdt ard h Easy to Install EntelliGuard™ Power Circuit Breakers are available in a Fixed and Draw-out Pattern. Each pattern offering the highest possible current rating when enclosed in a panel or equipment. Standard Heigth Independent of the number of poles, rated current or interruption rating, each of the two patterns has a common height, depth and cut-out dimension. This strongly simplifying the design of panels and equipment in which these devices are used(1). Features The basic breaker width has been optimized to allow for space to connect in- and outgoing bus bars and cables. Both Fixed and Draw-out Power Circuit Breaker types are supplied with rear connections suitable for Rear Access Horizontal busbar connection. The breakers are installed by using easily accessible mounting brackets, the drilling pattern of which exactly matches that of the previous M-PACT line(2). All accessories are wired out to an easy to access 39 or 78 pole terminal strip mounted on the breaker top. These terminals are amply sized to allow the use of up to 2,5 mm2 cabling and can be used with standard connection materials or AMP type plug connectors. Intro A C A Flexible ... Kit Form B A Power Circuit Breaker is normally supplied completely fitted OFF works. However the unique modular construction and field mountable Trip Unit and Accessories option can be used to acquire a breaker in kit form and to customize the device locally(3). C D Flexible ... Connections Besides the standard horizontal connection options multiple other options are available. B E Power Circuit Breakers supplied in a fixed pattern can be optionally supplied with Rear Vertical connections or Front access connections(4). F The Cassettes of the Breakers in Draw-out pattern are supplied with T or L stubs suitable for Horizontal Bubar connection. However these stubs can be rotated 90 degrees allowing the user to change the cassette connection option from Horizontal to Vertical Busbars. A 2nd cassette version is available allowing Front access Connection(4). A Standard Horizontal Rear Connections B Mounting Bracket C Terminal strip X (1) The width does vary (2) Except the new reduced size envelope 3 type (3) With GE training (4) Maximum 4000Amps 7 EntelliGuard™ Common Field Mountable Accessories Power Circuit Breaker Common Internal Accessories A large range of internal accessories as Electrical Operators (1), up to four Shunt Releases, Closing Coils or Undervoltage releases, Interlock Coils, Auxiliary and Alarm contacts, Carriage switches, Coil indication contacts and Breaker status switches are available. The Power Circuit Breaker front Facia includes ‘Pop up’ indicators that provide the user with an overview as to which accessories are installed in the device. Each of these devices can be acquired factory fitted or is available in a field mountable execution. The design is common to all three envelopes. Intro A ➎ 1 B 2 3 4 C 5 6 Electrical Operator Bell Alarm Switch A max of 4 Closing Coils, Shunt or Undervoltage releases Electronic Trip Unit A maximum of 8 Auxiliary Switches Ready to close or Spring Charged contact ➋ ➍ ➌ ➌ ➍ ➊ ➊ ➏ D E Common External Accessories Multiple common external accessories are available, a full overview of which can be found in section C of this catalogue. F On the left the Key lock and breaker interlock options are portrayed. Here up to four Ronis, Profalux or Castell locks can be used to lock the breaker, and up to two Ronis or Profalux locks to lock the draw-out breaker in its cassette. X Optionally groups of two or three Power Circuit Breakers in Fixed or Draw-out pattern can be interlocked. This in several different configurations, allowing the user to build an incoming power supply of multiple breakers to his own requirements. All Interlocks and Locking devices are only supplied factory fitted, the associated locks and cables are Field mountable. (1) Electrical Operator design is equivalent, however 1 type exists for envelope 1 and 1 for envelope 2 & 3 8 EntelliGuard™ Power Circuit Breakers Part of a total solution Using world class design and development tools like Six Sigma, computer simulation and Lean Manufacturing, the EntelliGuard™ is intended to meet and exceed the most stringent quality and safety standards. At GE we are proud to offer a product that will offer years of reliable and dependable protection. GE‘s name is synonymous with a broad range of products designed to meet our customer’s changing and competitive environment. Our drive to exceed our customer’s expectations is the foundation for continual renewal of our commitment to provide innovative low voltage solutions. Total Solution The new EntelliGuard™ and the existing Elfa Plus, Record Plus and Surion breaker and starter lines offer a full line of high-performance protection devices. They provide a fully co-ordinated approach to circuit and device protection for use in the Domestic, Commercial and Industrial environment. GE‘s new lines meet the latest technical standards and regulations and have been certified by authorities as Lovag, the KEMA and Lloyd’s. The components in these lines have been designed to be an integral part of a solution. A complete low voltage distribution and control range including components, accessories and the distribution and controls equipment they fit into. Intro A B C D E F X 9 EntelliGuard™ EN 60947-2 standard Power Circuit Breaker type Air Circuit Breaker denomination Poles Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Ue Power Circuit Breaker Category of use Suitable for use as an isolator Rated current In Ultimate breaking capacity Icu (kA) Service breaking capacity Ics (kA) Short-circuit withstand Icw (kA) Short-circuit Making current Icm 220-500V AC Short-circuit Making current Icm 690V AC Mechanical endurance Electrical endurance (CO operations at 440V AC) Ultimate breaking capacity Icu (kA) = Service breaking capacity Ics (kA) DC L/R = 15ms (nr. of poles in series) (1) Single phase breaking capacity IIT (kA) Intro Electronic Trip Units (1) GT -E type with Ammeter GT -S type with Ammeter, optional communication GT -N type with Measurement, optional communication GT -H type with Measurement & Relaying, optional communication A GG04 H E M 3, 4 1000 1250 1000 1250 12 690 1000 690 1000 750 750 B YES 400 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 65 85 85 40 50 50 50 50 105 143 187 187 220 84 105 143 187 187 20000 20000 12500 10000 10000 10000 50 65 35 50 20 35 20 30 32,5 50 GG07 H E M 3, 4 1000 1250 1000 1250 12 690 1000 690 1000 750 750 B YES 630 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 65 85 85 40 50 50 50 50 105 143 187 187 220 84 105 143 187 187 20000 20000 12500 10000 10000 10000 50 65 35 50 20 35 20 30 32,5 50 GG08 H E M 3, 4 1000 1250 1000 1250 12 690 1000 690 1000 750 750 B YES 800 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 85 85 100 50 65 65 85 100 40 50 65 85 85 35 50 50 65 65 85 85 40 50 50 50 50 105 143 187 187 220 84 105 143 187 187 20000 20000 12500 10000 10000 10000 50 65 35 50 20 35 20 30 32,5 50 X X X X X X X X X X X X GJ04 Non Auto GJ07 Non Auto GJ08 Non Auto S Number of Ui (Volts) Uimp (Kilovolt) Volts AC Volts DC Positive ON & OFF A at 50°C 230/240V-440V AC 500V AC 690V AC 1000V AC (4) 230/240V-440V AC 500V AC 690V AC 1000V AC (4) 1 second 3 seconds kA Peak kA Peak With Maintenance Without Maintenance Without Maintenance 250V DC 1 pole(1) 500V DC 2 poles(1) 750V DC 3 poles(1) 1000V DC 3 poles(1) 230/240-690V AC N LT & ST, - GF LT, ST, I or HI - GF LT, ST, I or HI, RELT GF, ZSI LT or LT+, ST, I or HI, RELT GFsum or GFct., ZSI S N S N EN 60947-3 standard Power Circuit Breaker type B Isolator denomination Poles Rated insulation voltage Rated impulse withstand voltage C Rated operational voltage Ue Category of use Suitable for use as a isolator Rated current In D Short-circuit withstand Icw (kA) Short-circuit Making current Icm 220-500V AC E Mechanical endurance (CO operations at 440V AC) Electrical endurance (CO operations at 440V AC) S Number of Ui (Volts) Uimp (Kilovolt) Volts AC Volts DC Positive ON & OFF A at 50°C 1 second 3 seconds kA Peak With Maintenance Without Maintenance Without Maintenance N 3, 4 1000 1000 12 690 690 B YES 400 50 65 40 50 88,2 143 20000 12500 10000 M S N 3, 4 3, 4 1250 1000 1000 12 12 1000 690 690 750 B B YES YES 400 630 85 50 65 50 40 50 187 88,2 143 20000 20000 10000 12500 10000 10000 M S N 3, 4 3, 4 1250 1000 1000 12 12 1000 690 690 750 B B YES YES 630 800 85 50 65 50 40 50 187 88,2 143 20000 20000 10000 12500 10000 10000 M 3, 4 1250 12 1000 750 B YES 800 85 50 187 20000 10000 10000 Installation F Fixed Pattern Dimensions in mm X Available connection modes Weights in Kg Height Width 3 pole Width 4 pole Depth (2) Rear Horizontal Rear Vertical Front 3 pole 4 pole 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 Height Width 3 pole Width 4 pole Depth (2) Rear Universal (3) Front 3 pole 4 pole 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 Draw-out pattern Dimensions in mm Available connection modes Weights in Kg (1) (2) (3) (4) 10 For dc applications a special trip unit is required With horizontal rear connections; indicated depth value is the required panel dimension T stubs can be rotated and used for both vertical & horizontal rear connection For use at 1000V phase seperators are required EntelliGuard™ S N 1000 690 65 65 50 50 50 40 65 65 50 50 40 105 84 65 50 143 105 20000 12500 10000 50 35 20 20 32,5 E M 1000 1250 1000 690 1000 750 690 85 85 85 100 100 85 50 85 100 85 100 85 85 50 85 85 50 50 187 220 187 187 20000 10000 10000 65 50 35 30 50 S N 50 50 40 65 65 50 50 50 40 65 65 50 50 40 105 84 65 50 143 105 20000 12500 10000 GG13 H 3, 4 1250 12 1000 750 B YES 1250 85 65 65 35 85 65 65 35 65 50 187 143 50 35 20 20 32,5 E M 1000 1250 1000 690 1000 750 690 85 85 85 100 100 85 50 85 100 85 100 85 85 50 85 85 50 50 187 220 187 187 20000 10000 10000 65 50 35 30 50 S N 50 50 40 65 65 50 50 50 40 65 65 50 50 40 105 84 65 50 143 105 20000 12500 10000 GG16 H 3, 4 1250 12 1000 750 B YES 1600 85 65 65 35 85 65 65 35 65 50 187 143 50 35 20 20 32,5 E M 1000 1250 1000 690 1000 750 690 85 85 85 100 100 85 50 85 100 85 100 85 85 50 85 85 50 50 187 220 187 187 20000 10000 10000 65 50 35 30 50 S N 50 50 40 65 65 50 50 50 40 65 65 50 50 40 105 84 65 50 143 105 20000 12500 8000 GG20 H 3, 4 1250 12 1000 750 B YES 2000 85 65 65 35 85 65 65 35 65 50 187 143 50 35 20 20 32,5 E M 1000 1250 690 1000 750 85 85 85 100 100 85 50 85 100 85 100 85 85 50 85 85 50 50 187 220 187 187 20000 10000 6000 65 50 35 30 50 Performance Ratings 50 50 40 GG10 H 3, 4 1250 12 1000 750 B YES 1000 85 65 65 35 85 65 65 35 65 50 187 143 Intro S N 3, 4 1000 1000 12 690 690 B YES 1000 50 65 40 50 88,2 143 20000 12500 10000 X X X X X X X X X X X X X X X X GJ10 Non Auto GJ13 Non Auto GJ16 Non Auto GJ20 Non Auto M 3, 4 1250 12 1000 750 B YES 1000 85 50 187 20000 10000 10000 S N 3, 4 1000 1000 12 690 690 B YES 1250 50 65 40 50 88,2 143 20000 12500 10000 M 3, 4 1250 12 1000 750 B YES 1250 85 50 187 20000 10000 10000 S N 3, 4 1000 1000 12 690 690 B YES 1600 50 65 40 50 88,2 143 20000 12500 10000 M 3, 4 1250 12 1000 750 B YES 1600 85 50 187 20000 10000 10000 S N 3, 4 1000 1000 12 690 690 B YES 2000 50 65 40 50 88,2 143 20000 12500 8000 A B M 3, 4 1250 12 1000 750 B YES 2000 85 50 187 10000 5000 5000 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 442 342 442 328 X X X 43 54 442 432 562 328 X X X 53 68 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 444 343 443 453 X X 82 100 444 443 573 453 X X 131 164 C D E F X 11 EntelliGuard™ EN 60947-2 standard Power Circuit Breaker Power Circuit Breaker type Air Circuit Breaker denomination Poles Rated insulation voltage Rated impulse withstand voltage Intro GG25 H M Number of 3, 4 Ui (Volts) 1000 1250 Uimp (Kilovolt) 12 Volts AC 690 1000 Rated operational voltage Ue Volts DC 750 B Category of use Positive ON & OFF YES Suitable for use as an isolator A at 50°C 2500 Rated current In 230/240V-440V AC 65 85 100 500V AC 65 85 100 Ultimate breaking capacity Icu (kA) 690V AC 50 85 85 1000V AC (6) 50 230/240V-440V AC 65 85 100 65 85 100 500V AC Service breaking capacity Ics (kA) 690V AC 50 85 85 (6) 50 1000V AC 1 second 65 85 85 Short-circuit withstand Icw (kA) 3 seconds 50 50 50 143 187 220 Short-circuit Making current Icm 220-500V AC kA Peak 105 187 187 Short-circuit Making current Icm 690V AC kA Peak With Maintenance 20000 Mechanical endurance Without Maintenance 10000 Electrical endurance Without Maintenance 6000 (CO operations at 440V AC) 250V DC 1 pole(1) 50 Ultimate breaking capacity Icu (kA) 35 = Service breaking capacity Ics (kA) DC L/R 500V DC 2 poles(1) (1) (1) = 15ms (nr. of poles in series) 750V DC 3 poles 20 30 1000V DC 3 poles(1) 230/240-690V AC 50 Single phase breaking capacity IIT (kA) B GG32 & GH32 (4) H M G L 3, 4 1000 1250 1000 1250 12 690 1000 690 1000 750 750 B YES 3200 65 85 100 100 150 65 85 100 100 130 50 85 85 100 100 50 80 65 85 100 100 150 65 85 100 100 130 50 85 85 100 100 50 80 65 85 85 100 100 50 50 50 85 85 143 187 220 220 330 105 187 187 220 220 20000 10000 10000 5000 N 5000 LT & ST, - GF LT, ST, I or HI - GF LT, ST, I or HI, RELT GF, ZSI LT or LT+, ST, I or HI, RELT GFsum or GFct., ZSI Power Circuit Breaker type Isolator denomination Poles Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Ue D Number of Ui (Volts) Uimp (Kilovolt) Volts AC Volts DC Category of use Suitable for use as a isolator Rated current In Positive ON & OFF A at 50°C 1 second Short-circuit Withstand Icw (kA) 3 seconds Short-circuit Making current Icm 220-500V AC kA Peak With Maintenance Mechanical Endurance (CO operations at 440V AC) Without Maintenance Electrical Endurance Without Maintenance (CO operations at 440V AC) E F 5000 65 50 35 30 50 5000 65 50 35 30 65 5000 65 50 35 30 50 1500 65 50 35 30 65 1500 65 50 35 30 65 65 50 35 65 X X X X X X X X X X X X X X X X X X X X GJ25 Non Auto GJ32 & GK32 (4) Non Auto M 3, 4 1250 12 1000 750 B YES 3200 85 50 187 10000 5000 B YES 4000 65 50 143 20000 10000 GJ40 & GK40 (4) Non Auto M 3, 4 1250 12 1000 750 B YES 4000 85 50 187 10000 5000 5000 5000 5000 EN 60947-3 standard C GG40 & GH40 (4) GG50 GG64 H M G L M L M L 3, 4 3, 4 3, 4 1000 1250 1000 1250 1000 1250 1000 1000 12 12 12 690 1000 690 1000 690 1000 690 690 750 750 750 750 B B B YES YES YES 4000 5000 6400 65 85 100 100 150 100 150 100 150 65 85 100 100 130 100 130 100 130 50 85 85 100 100 100 100 100 100 50 80 80 65 85 100 100 150 100 150 100 150 65 85 100 100 130 100 130 100 130 50 85 85 100 100 100 100 100 100 50 80 80 65 85 85 100 100 100 100 100 100 50 50 50 85 85 85 85 85 85 143 187 220 220 330 220 330 220 330 105 187 187 220 220 220 220 220 220 20000 10000 10000 10000 10000 5000 5000 5000 N Electronic Trip Units (1) GT -E type with Ammeter GT -S type with Ammeter, optional communication GT -N type with Measurement, optional communication GT -H type with Measurement & Relaying, optional communication A N N 3, 4 1000 12 690 B YES 2500 65 50 143 20000 10000 M 3, 4 1250 12 1000 750 B YES 2500 85 50 187 10000 5000 N 3, 4 1000 12 690 6000 5000 5000 B YES 3200 65 50 143 20000 10000 N 3, 4 1000 12 690 GJ50 Non Auto L 3, 4 1250 12 1000 750 B YES 5000 100 85 220 10000 5000 GJ64 Non Auto L 3, 4 1250 12 1000 750 B YES 6400 100 85 220 10000 5000 1500 1500 Installation Fixed Pattern X Dimensions in mm Available connection modes Weights in Kg Height Width 3 pole Width 4 pole Depth (2) Rear Horizontal Rear Vertical Front 3 pole 4 pole 442 432 562 328 X X X 53 68 442 432 562 328 X X X 53 68 442 737 967 328 X X Height Width 3 pole Width 4 pole Depth (2) Rear Universal(3) Front 3 pole 4 pole 444 443 573 453 X X 131 164 444 443 573 453 X X 131 164 444 743 973 488 X 90 115 442 432 562 328 X X 53 68 442 737 967 328 X X 442 737 967 328 X X 442 737 967 328 90 115 90 115 90 115 444 743 973 488 X 444 743 973 488 X 444 743 973 488 X (5) 220 275 220 275 220 275 X Draw-out pattern Dimensions in mm Available connection modes Weights in Kg (1) For dc applications a special trip unit is required 12 (2) (3) (4) (5) (6) 220 275 444 443 573 488 X (5) X 131 164 With horizontal rear connections; indicated depth value is the required panel dimension T stubs can be rotated and used for both vertical & horizontal rear connection GH and GK types (100% rated types) are only available in draw-out pattern in vertical connection mode T stubs can only be used for vertical rear connections For use at 1000V phase seperators are required EntelliGuard™ Performance Ratings Application Software The new HD 384 (1) and R064-03 standards require that the design of a low voltage distribution system includes the determination of all prospective short-circuit and fault currents levels. GE has developed a windows based software package to do this ‘Procera Plus’: A multi-standard and multi-lingual software package to accompany our new product line. Intro A B GE Energy Industrial Solutions C PowerDesign D v1.1 Design and Quotations software for low voltage installations E F GE imagination at work X Design Software GE provides a software package PowerDesign to configure the widely used & well known GE system enclosure ranges ‘QuiXtra 630’, ‘ModulaPlus’ and ‘SEN Plus’, and to use them with components as Electrical Distribution panels. The software provides the user with a varied and simple range of user friendly tools and features to design and configure devices and enclosures following an electrical component mounting logic. The PowerDesign package also includes a tool that allows the user to configure the new EntelliGuard™ Power Circuit Breaker, its catalogue code and defines the subcomponents of which it is built. (1) Also available in IEC 60364 version 13 EntelliGuard™ Power Circuit Breaker Notes Intro A B C D E F X 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EntelliGuard™ Power Circuit Breakers A.2 EntelliGuard™: How to order in 8 steps A.4 Basic breakers executed in a fixed mounting pattern A.5 Isolators or Non Automatic Breakers in a fixed mounting pattern A.6 Termination sets for Breakers & Isolators in fixed mounting pattern A.8 Basic breakers: Draw-out Breakers; Moving Portion only A.10 Isolators or Non Automatic Breakers: Draw-out Patterns; Moving Portion only A.11 Cassettes for use with Breakers & Isolators in Draw-out Pattern; Factory mounted A.12 Trip Units; Factory mounted The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X Internal Accessories A.17 Factory mounted A.20 Field mountable A.23 Installation Accessories A.24 Sensors for Trip Units A.25 Cassettes for use with Breakers & Isolators in Draw-out Pattern; Field mountable A.26 Field Mounted (spare) Trip Units A.28 Spare Parts Global Catalogue number structure A.30 Breaker A.33 Cassette Valid Catalogue number combinations A.34 Factory mounted: Available standard Breaker & Cassette types A.35 Factory mounted: Available standard Breaker, Cassette and Trip Unit types A.36 Factory mounted: Available standard Isolator & Cassette types A.38 Accessories; Factory and Field mountable A.1 EntelliGuard™ Step 1 Step 2 Step 3 Choose Current rating Choose required Interruption Rating Define if a Breaker or Isolator is needed Proceed to establish the first 5 digits of the Catalogue Number as indicated here In 400A Intro 800A A 1000A B 1250A C 1600A D 2000A E 2500A 3200A 4000A X Icu = Ics Icw Envelope ≤ 440V AC 630A F Step 4 5000A 6400A 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 65kA 85kA 100kA 65kA 85kA 100kA 100kA 150kA 65kA 85kA 100kA 100kA 150kA 100kA 150kA 100kA 150kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 65kA 85kA 85kA 65kA 85kA 85kA 100kA 100kA 65kA 85kA 85kA 100kA 100kA 100kA 100kA 100kA 100kA 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 2 2 2 2 2 2 3 3 2 2 2 3 3 3 3 3 3 Standard 100% Rated (1) Breaker Isolator GG04S GG04N GG04H GG04E GG04M GG07S GG07N GG07H GG07E GG07M GG08S GG08N GG08H GG08E GG08M GG10S GG10N GG10H GG10E GG10M GG13S GG13N GG13H GG13E GG13M GG16S GG16N GG16H GG16E GG16M GG20S GG20N GG20H GG20E GG20M GG25N GG25H GG25M GG32N GG32H GG32M GG32G GG32L GG40N GG40H GG40M GG40G GG40L GG50M GG50L GG64M GG64L GJ04S GW04N Breaker Isolator(1) 4 = Breaker / Isolator In Fixed Pattern 3 pole GJ07S GW07N GW07M 6 = Breaker / Isolator In Fixed Pattern 4 pole(1) GJ08S GW08N GW08M GJ10S GW10N GW10M GJ13S GW13N 1 = Breaker / Isolator Moving Portion Only 3 pole GW13M GJ16S GW16N 3 = Breaker / Isolator Moving Portion Only 4 pole(2) GJ16M GJ20S GW20N GW20M GJ25N GW25H GJ32N GW32M GH32N GH32H GH32M GK32N GZ32H GH40N GH40H GH40M GK40N GZ40H GJ32L GJ40N GW40M GJ40L 2 = Cassette for Draw-out Pattern = Fixed Portion Only 3 pole 5 = Cassette for Draw-out Pattern = Fixed Portion Only 4 pole(3) GJ50L GJ64L Examples Breaker 4p 1600A- Draw-out Portion only- Icu=85kA, Ics=Icw=65kA: GG16H3 Breaker 3p 3200A Fixed Pattern -Horizontal Rear Connections - Icu=Ics=Icw=65kA: GG32N4 Defines the 6th digit In catalogue number GW04M (1) On Isolators Icu and Ics values do not apply A.2 Select the required product A - Breaker or Isolator In Fixed Pattern B - Breaker or Isolator As Draw-out, Moving Portion C - Cassette for Draw-out Breaker or Isolator } } } Order codes How to order (2) 4 pole Neutral Left EntelliGuard™ in 8 steps Step 5 Basic Catalogue number is a Manually operated device If a Motor Operated device is requested? Please order Motor and closing coils as Indicated here (3) Step 7 If Universal internal Accessories(3) are needed? Options UVR or SHT release (s) Network Interlocks Auxiliary contacts Alarm & signal contacts Step 8 Full Catalogue number defines: A Breaker without Trip Unit For all Breakers ADD Trip Unit completing the basic catalogue number Add Catalogue number (s) Add Catalogue number (s) Add Catalogue number (s) No addition Indicates Breaker / Isolator In Fixed Pattern has set of 3NO/3NC aux. Contacts included Breaker in fixed Pattern Are equipped with Rear Connection (Horizontal) Other options include Rear (Vertical) and Front (Flat) See page A 6 to order Field mountable Adaptation Kits If chosen device is a Breaker or Isolator Envelope 1 See page A.17 Order a Motor Type1 and 1 Closing Coil or 1 Command closing coil Based on voltage Requirements and specifications If chosen device is a Breaker or Isolator See page A.17 To add up to 3 SHT or UVR Releases Or 1 Network Interlock Coils and 1 SHT or UVR Release If chosen device is a Breaker See pages A.12 to A.16 Choose and Add a Trip Unit out of the the four basic types and 39 different options. Offering An Extremely Large setting range covering Overload, Delayed and Instantaneous Short-circuit Protection If chosen device is a Breaker or Isolator Envelope 2 or 3 See page A.17 Order a Motor type 2 and 1 Closing Coil or 1 Command closing coil Based on voltage Requirements and specifications If chosen device is a Breaker or Isolator See page A.17 To extend on the installed 3 NO + 3NC contacts Maximum of 8 possible See pages A.4, 5 & 6 No addition Indicates Breaker / Isolator Moving Portion Only has set of 3NO/3NC aux. Contacts included See pages A.7, 8 & 9 U = Cassette with Universal 'T stabs' suited for use as Horizontal or Vertical rear connections Safety Shutters Supplied with Cassette (3) V = Cassette with Vertical Rear Connections Safety Shutters Supplied with Cassette (3) F = Cassette with Front Flat connections Safety Shutters Supplied with Cassette (3) See page A.11 If chosen device is a Breaker or Isolator See page A.17 To add Bell Alarm and/or Coils signalling contacts How to order in 8 steps Finalize the basic Catalogue number see catalogue pages: A.4-A.5 - Fixed Pattern A.8-A.10 - Draw-out Portion A.6 - Connections fixed pattern A.11 - Cassettes, draw-out Step 6 Intro A Groundfault Protection in Single or Dual mode suited for applications as UEF, REF & SEF or combinations thereof B Complete and sophisticated Network measurement options, Including Wave Form Capture C Multiple relaying options as Zone Selective Interlock, Undervoltage, Overvoltage, Reverse Power etc. D If chosen device is a Cassette See page A.17 & A.18 To Add Position indication Contacts in Cassette Or provisions for key interlocks E F - Or A 2nd ordering method can be used in which the fully configured breaker or cassette is defined in one character string. This string comprises 19 digits when used for the breaker and 12 for when used for the cassette. This global ordering code is referred to within GE as the: Catalogue Number It is used on all relevant ordering documents and printed on each EntelliGuard™ breaker front facia. An explanation of this code and its use can be found on page A.30 of this catalogue. X When ordering with the method indicated here our CRC department will define and confirm the mentioned individual Catalogue Number. (3) Devices ordered here are supplied factory fitted Remark: For Field Mountable Accessories see page A.21 to A.25 A.3 EntelliGuard™ Basic breakers executed in a fixed mounting pattern - With Horizontal Rear Connection (for other options, please refer to page A.6)(1) With Aux. contact block equipped with 3 NO and 3 NC contacts Basic Breaker MUST be equipped with a Trip Unit (for options, please refer to page A.12 to A.16) For 1000V applications (M and L types) phase seperators are required (see page A.23) Fixed Mounting Pattern 4 pole(2) Order codes 3 pole S type Icu = Ics = Icw 50kA N type Intro Icu = Ics = lcw 65kA A H type Icu = Ics = 85kA lcw = 65kA B C E-H type Icu = Ics = Icw 85kA D E M type F Icu = Ics = 100kA Icw = 85kA X G-M type Icu = Ics = Icw 100kA L type Icu = Ics = 150kA Icw = 100kA Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 400 630 800 1000 1250 1600 2000 GG04S4 GG07S4 GG08S4 GG10S4 GG13S4 GG16S4 GG20S4 407019 407048 407078 407108 407138 407168 407208 GG04S6 GG07S6 GG08S6 GG10S6 GG13S6 GG16S6 GG20S6 407020 407049 407079 407109 407139 407169 407209 400 630 800 1000 1250 1600 2000 2500 3200 4000 GG04N4 GG07N4 GG08N4 GG10N4 GG13N4 GG16N4 GG20N4 GG25N4 GG32N4 GG40N4 407015 407044 407074 407104 407134 407164 407204 407240 407266 407292 GG04N6 GG07N6 GG08N6 GG10N6 GG13N6 GG16N6 GG20N6 GG25N6 GG32N6 GG40N6 407016 407045 407075 407105 407135 407165 407205 407241 407267 407293 400 630 800 1000 1250 1600 2000 GG04H4 GG07H4 GG08H4 GG10H4 GG13H4 GG16H4 GG20H4 407007 407036 407066 407096 407126 407156 407196 GG04H6 GG07H6 GG08H6 GG10H6 GG13H6 GG16H6 GG20H6 407008 407037 407067 407097 407127 407157 407197 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) GG04E4 GG07E4 GG08E4 GG10E GG13E4 GG16E4 GG20E4 GG25H4 GG32H4 GG40H4 407003 407032 407062 407092 407122 407152 407192 407232 407244 407280 GG04E6 GG07E6 GG08E6 GG10E6 GG13E6 GG16E6 GG20E6 GG25H6 GG32H6 GG40H6 407004 407033 407063 407093 407123 407153 407193 407233 407245 407281 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) GG04M4 GG07M4 GG08M4 GG10M4 GG13M4 GG16M4 GG20M4 GG25M4 GG32M4 GG40M4 407011 407040 407070 407100 407130 407160 407200 407236 407262 407288 GG04M6 GG07M6 GG08M6 GG10M6 GG13M6 GG16M6 GG20M6 GG25M6 GG32M6 GG40M6 407012 407041 407071 407101 407131 407161 407201 407237 407263 407289 3200 4000 5000 6400 GG32G4 GG40G4 GG50M4 GG64M4 407252 407270 407306 407326 GG32G6 GG40G6 GG50M6 GG64M6 407253 407271 407307 407327 3200 4000 5000 6400 GG32L4 GG40L4 GG50L4 GG64L4 407254 407284 407302 407322 GG32L6 GG40L6 GG50L6 GG64L6 407255 407285 407303 407323 (1) Rear Vertical Connection for Indicated 4000A types (2) 4th pole on Left, Trip Unit Field Configurable at 0,50 or 100% of phase rating A.4 EntelliGuard™ Isolators or Non Automatic breakers executed in a fixed mounting pattern - With Horizontal Rear Connection (for other options, please refer to page A.6)(1) - With Aux. contact block equipped with 3 NO and 3 NC contacts - For 1000V applications (M and L types) phase seperators are required (see page A.23) 4 pole(2) 3 pole S type Non Automatic Icw 50kA N type Non Automatic Icw 65kA M type Non Automatic Icw 85kA L type Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 400 630 800 1000 1250 1600 2000 GJ04S4 GJ07S4 GJ08S4 GJ10S4 GJ13S4 GJ16S4 GJ20S4 407380 407400 407420 407440 407460 407480 407500 GJ04S6 GJ07S6 GJ08S6 GJ10S6 GJ13S6 GJ16S6 GJ20S6 407381 407401 407421 407441 407461 407481 407501 400 630 800 1000 1250 1600 2000 2500 3200 4000 (1) GW04N4 GW07N4 GW08N4 GW10N4 GW13N4 GW16N4 GW20N4 GJ25N4 GJ32N4 GJ40N4 407376 407396 407416 407436 407456 407476 407496 407520 407539 407560 GW04N6 GW07N6 GW08N6 GW10N6 GW13N6 GW16N6 GW20N6 GJ25N6 GJ32N6 GJ40N6 407377 407397 407417 407437 407457 407477 407497 407521 407540 407561 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) GW04M4 GW07M4 GW08M4 GW10M4 GW13M4 GW16M4 GW20M4 GW25M4 GW32M4 GW40M4 408350 408352 408354 408356 408358 408360 408362 408364 408366 408368 GW04M6 GW07M6 GW08M6 GW10M6 GW13M6 GW16M6 GW20M6 GW25M6 GW32M6 GW40M6 408351 408353 408355 408357 408359 408361 408363 408365 408367 408369 3200 4000 5000 6400 GJ32L4 GJ40L4 GJ50L4 GJ64L4 407535 407556 407567 407577 GJ32L6 GJ40L6 GJ50L6 GJ64L6 407536 407557 407568 407578 Fixed Mounting Pattern Fixed Mounting Pattern Intro A B C D Non Automatic Icw 100kA E (1) Rear Vertical Connection for Indicated 4000A types (2) 4th pole on Left F X A.5 EntelliGuard™ Termination sets for Breakers & Isolators in fixed pattern - To modify Standard connection (Horizontal Rear) to: Vertical Rear Front flat connection Sets containing terminals and hardware for the line & load side of the breaker Termination sets for Breakers & Isolators in fixed Pattern Vertical Rear Connections Suited for use with EntelliGuard™ types Order codes Rating (A) 3 pole 4 pole Cat. No. Ref. No. Cat. No. Ref. No. Terminations for envelope 1 400 - 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H G16H4RVI G20H4RVIn 408058 408059 G16H6RVI G20H6RVIn 408082 408083 Terminations for envelope 2 400 - 3200A GG, GJ & GW type E, N, H & M 4000A(2) GG, GJ & GW type N, H & M G32M4RVI G40M4RVI 408070 408072 G32M6RVI G40M6RVI 408071 408074 Terminations for envelope 3 3200 - 6400A GG & GJ type G, M & L G64L4RVI 408073 G64L6RVI 408075 Terminations for envelope 1 400 - 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H G16H4FFI G20H4FFI 408060 408061 G16H6FFI G20H6FFI 408062 408063 Terminations for envelope 2 400 - 3200A GG, GJ & GW type E, N, H & M 4000A GG, GJ & GW type N, H & M G32M4FFI G40M4FFI 408066 408067 G32M6FFI G40M6FFI 408068 408069 GFMTG 408085 GFMTG 408085 Front access Connections Intro A B Wall mounting Brackets(1) Wall Mounting Brackets for Env. 1 & 2 C D (1) Recommended for use with Front access Connections (2) For the 4000A types are supplied with the standard fixed breaker E F X A.6 EntelliGuard™ Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminations; Fixed Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro A B C D E F X A.7 EntelliGuard™ Basic breakers: Draw-out Breakers; Moving portion only - With Aux. contact block equipped with 3 NO and 3 NC contacts - Basic Breaker MUST be equipped with a Trip Unit (please refer to page A.12 to A.16 for options) - A cassette is needed, please refer to page A.11 for options - For 1000V applications (M and L types) phase seperators are required (see page A.23) Draw-out Pattern; moving portion only 4 pole(1) 3 pole Order codes S type Icu = Ics = Icw 50kA N type Intro Icu = Ics = Icw 65kA A H type Icu = Ics = 85kA Icw = 65kA B C E-H type Icu = Ics = Icw 85kA D E M type F Icu = Ics = 100kA Icw = 85kA X G-M type Icu = Ics = Icw 100kA L type Icu = Ics = 150kA Icw = 100kA Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 400 630 800 1000 1250 1600 2000 GG04S1 GG07S1 GG08S1 GG10S1 GG13S1 GG16S1 GG20S1 407017 407046 407076 407106 407136 407166 407206 GG04S3 GG07S3 GG08S3 GG10S3 GG13S3 GG16S3 GG20S3 407018 407047 407077 407107 407137 407167 407207 400 630 800 1000 1250 1600 2000 2500 3200 4000 GG04N1 GG07N1 GG08N1 GG10N1 GG13N1 GG16N1 GG20N1 GG25N1 GG32N1 GG40N1 407013 407042 407072 407102 407132 407162 407202 407238 407264 407290 GG04N3 GG07N3 GG08N3 GG10N3 GG13N3 GG16N3 GG20N3 GG25N3 GG32N3 GG40N3 407014 407043 407073 407103 407133 407163 407203 407239 407265 407291 400 630 800 1000 1250 1600 2000 GG04H1 GG07H1 GG08H1 GG10H1 GG13H1 GG16H1 GG20H1 407005 407034 407064 407094 407124 407154 407194 GG04H3 GG07H3 GG08H3 GG10H3 GG13H3 GG16H3 GG20H3 407006 407035 407065 407095 407125 407155 407195 400 630 800 1000 1250 1600 2000 2500 3200 4000 GG04E1 GG07E1 GG08E1 GG10E1 GG13E1 GG16E1 GG20E1 GG25H1 GG32H1 GG40H1 407001 407030 407060 407090 407120 407150 407190 407230 407242 407278 GG04E3 GG07E3 GG08E3 GG10E3 GG13E3 GG16E3 GG20E3 GG25H3 GG32H3 GG40H3 407002 407031 407061 407091 407121 407151 407191 407231 407273 407279 400 630 800 1000 1250 1600 2000 2500 3200 4000 GG04M1 GG07M1 GG08M1 GG10M1 GG13M1 GG16M1 GG20M1 GG25M1 GG32M1 GG40M1 407009 407038 407068 407098 407128 407158 407198 407234 407260 407286 GG04M3 GG07M3 GG08M3 GG10M3 GG13M3 GG16M3 GG20M3 GG25M3 GGM3M3 GG40M3 407010 407039 407069 407099 407129 407159 407199 407235 407261 407287 3200 4000 5000 6400 GG32G1 GG40G1 GG50M1 GG64M1 407250 407268 407304 407324 GG32G3 GG40G3 GG50M3 GG64M3 407251 407269 407305 407325 3200 4000 5000 6400 GG32L1 GG40L1 GG50L1 GG64L1 407248 407282 407300 407320 GG32L3 GG40L3 GG50L3 GG64L3 407249 407283 407301 407321 (1) 4th pole on Left, Trip Unit Field Configurable at 0,50 or 100% of phase rating A.8 EntelliGuard™ - Draw-out Breaker with no or very limited de-rating when used enclosed With Aux. contact block equipped with 3 NO and 3 NC contacts Basic Breaker MUST be equipped with a Trip Unit (please refer to page A.12 to A.16 for options) A cassette with vertical clusters is needed, please refer to page A.11 for options Draw-out Pattern, vertical clusters; moving portion only 4 pole(1) 3 pole N type Icu = Ics = Icw 65kA H type Icu = Ics = Icw 85kA M type Icu = Ics = 100kA Icw = 85kA Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 3200 4000 GH32N1 GH40N1 407350 407356 GH32N3 GH40N3 407351 407357 3200 4000 GH32H1 GH40H1 407346 407352 GH32H3 GH40H3 407347 407353 3200 4000 GH32M1 GH40M1 407348 407354 GH32M3 GH40M3 407349 407355 Draw-out Pattern; moving portion Draw-out Breakers with vertical dual clusters; Moving portion only (1) 4th pole on Left, Trip Unit Configurable at 0,50 or 100% of phase rating Intro A B C D E F X A.9 EntelliGuard™ Isolators or Non Automatic Breakers: Draw-out Pattern; Moving portion only - With Aux. contact block equipped with 3 NO and 3 NC contacts - A cassette is needed, please refer to page A.11 for options - For 1000V applications (M and L types) phase seperators are required (see page A.23) Draw-out Pattern; moving portion only 4 pole(1) 3 pole S type Order codes Non Automatic Icw 50kA N type Non Automatic Icw 65kA Intro A M type B Non Automatic Icw 85kA C D L type Non Automatic Icw 100kA Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 400 630 800 1000 1250 1600 2000 GJ04S1 GJ07S1 GJ08S1 GJ10S1 GJ13S1 GJ16S1 GJ20S1 407378 407398 407418 407438 407458 407478 407498 GJ04S3 GJ07S3 GJ08S3 GJ10S3 GJ13S3 GJ16S3 GJ20S3 407379 407399 407419 407439 407459 407479 407499 400 630 800 1000 1250 1600 2000 2500 3200 4000 GW04N1 GW07N1 GW08N1 GW10N1 GW13N1 GW16N1 GW20N1 GJ25N1 GJ32N1 GJ40N1 407374 407394 407414 407434 407454 407474 407494 407518 407537 407558 GW04N3 GW07N3 GW08N3 GW10N3 GW13N3 GW16N3 GW20N3 GJ25N3 GJ32N3 GJ40N3 407375 407395 407415 407435 407455 407475 407495 407519 407538 407559 400 630 800 1000 1250 1600 2000 2500 3200 4000 GW04M1 GW07M1 GW08M1 GW10M1 GW13M1 GW16M1 GW20M1 GW25M1 GW32M1 GW40M1 408400 408402 408404 408406 408408 408410 408412 408414 408416 408418 GW04M3 GW07M3 GW08M3 GW10M3 GW13M3 GW16M3 GW20M3 GW25M3 GW32M3 GW40M3 408401 408403 408405 408407 408409 408411 408413 408415 408417 408419 3200 4000 5000 6400 GJ32L1 GJ40L1 GJ50L1 GJ64L1 407533 407554 407565 407575 GJ32L3 GJ40L3 GJ50L3 GJ64L3 407534 407555 407566 407576 E Power Circuit Breakers types with Vertical Cluster system F Isolators or Non Automatic Breakers with dual vertical clusters; Moving Portion only - Draw-out Patterns with no or very limited de-rating when used enclosed - With Aux. contact block equipped with 3 NO and 3 NC contacts - A cassette with vertical clusters is needed, please refer to page A.11 for options X Draw-out Pattern, vertical clusters; moving portion only 4 pole(1) 3 pole N type Non Automatic Icw 65kA H type Non Automatic Icw 85kA (1) 4th pole on Left A.10 Rating (A) Cat. No. Ref. No. Cat. No. Ref. No. 3200 4000 GK32N1 GK40N1 407591 407595 GK32N3 GK40N3 407592 407596 3200 4000 GZ32H1 GZ40H1 407589 407593 GZ32H3 GZ40H3 407590 407594 EntelliGuard™ Cassettes for use with Breakers & Isolators in Draw-out Pattern; Factory mounted Cassettes for Draw-out Pattern; fixed portion only Universal Rear Connections 3 pole Rating (A) Suited for use with EntelliGuard™ -G types 4 pole Cat. No. Ref. No. Cat. No. Ref. No. Cassette for envelope 1 400 - 1600A GG, GJ & GW type S 400 - 1600A GG, GJ & GW type N & H 2000A GG, GJ & GW type S, N & H GG16S2UM GG16H2UM GG20H2UM 407616 408202 408212 GG16S5UM GG16H5UM GG20H5UM 407618 408205 408215 Cassette for envelope 2 400 - 2000A GG, GJ & GW type N, E & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M(1) 4000A GG, GJ & GW type N, H & M(1) GG20M2UM GG25M2UM GG32M2UM GG40M2UM 408224 408236 408247 408259 GG20M5UM GG25M5UM GG32M5UM GG40M5UM 408227 408239 408251 408263 GG64L2UM 408281 GG64L5UM 408283 Remark: Each cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. Cassette for envelope 3 (2) 3200 - 6400A(3) GG & GJ type G, M & L Draw-out Pattern: cassettes - References apply for Cassettes supplied in one Packaging with Breakers or Isolators (for Separate Cassettes see page A.25) - With Connection modes as indicated in left column - Each cassette is supplied with safety shutters Intro A Vertical rear Connections Cassette with dual vertical clusters and connection pads for limited de-rating envelope 2 3200A GH, GK, GJ & GZ type N.H & M 4000A GH, GK, GJ & GZ type N.H & M(1) GH32M2VM GH40M2VM 408292 408294 GH32M5VM GH40M5VM 408293 408295 B C Front access Connections Cassette for envelope 1 400 - 1600A GG, GJ & GW type S 400 - 1600A GG, GJ & GW type N & H 2000A GG, GJ & GW type S, N & H GG16S2FM GG16H2FM GG20H2FM 407626 408200 408210 GG16S5FM GG16H5FM GG20H5FM 407628 408203 408213 D E Cassette for envelope 2 400 - 2000A GG, GJ & GW type E, N, H & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M GG20M2FM GG25M2FM GG32M2FM GG40M2FM (1) Cassettes for envelope 2 are limited to a current of 3200A when connected in horizontal mode. Connected in vertical mode a 4000A rating is achieved (2) The Cassette for envelope 3 is limited to a current of 5000A when connected in horizontal mode Connected in vertical mode it has a rating of 6400A. This cassette type is NOT depicted here (3) 4th pole on Left 408222 408234 408245 408257 GG20M5FM GG25M5FM GG32M5FM GG40M5FM 408225 408237 408249 408261 F X A.11 EntelliGuard™ Trip Units - Factory mounted GT- E Basic functionality LT-C LTDB ST Designation Extended functionality GT-E Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB None GTG00K1-SF Cat. No. Ref. No. 408800 GT-Rating Plug Required for all types GTPUNI 408860 GT-E Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB GF I²t ON or OFF GFDB None GTG00K2-SF 408801 GT-Rating Plug Required for all types GTPUNI 408860 GT-S Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB I None GTG00K9-SF 408803 GT-Rating Plug Required for all types GTPUNI 408860 GT-S Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB GF I²t ON or OFF GFDB I None GTG00K3-SF 408805 + Modbus Communication GTG00K3-2SF 408807 GT-Rating Plug Required for all types GTPUNI 408860 GT-S Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB GF I²t ON or OFF GFDB I ext. None GTG00K4-SF 408806 + Modbus Communication GTG00K4-2SF 408808 GT-Rating Plug Required for all types GTPUNI 408860 2 I t on Order codes STDB LT-C LTDB ST Intro I2 t on STDB GF I2 t on GFDB A GT- S LT-C B LTDB ST I2 t on C STDB I D LT-C E F LTDB ST I2 t on STDB GF 2 I t on I GFDB X LT-C LTDB ST I2 t on STDB GF I2 t on GFDB A.12 l ext. EntelliGuard™ Trip Units - Factory mounted GT- N Basic functionality LT-C LTDB I2 t on STDB Extended functionality Cat. No. Ref. No. GT-N Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB I RELT Measurement unit (1) RELT Instantaneous GTG00K9-4SF 408813 GT-Rating Plug Required for all types GTPUNI 408860 GT-N Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB GF I²t ON or OFF GFDB I RELT Measurement unit (1) RELT Instantaneous GTG00K3-4SF 408815 + Modbus Communication + Zone Selective Interlock on I, ST & GF functions GTG00K3T6SF 408817 GT-Rating Plug Required for all types GTPUNI I Extended functionality RELT Electronic Trip Units ST Designation Basic functionality LT-C LTDB ST I2 t on Intro A STDB GF I2 t on I 408860 GFDB Extended functionality B C RELT D Basic functionality LT-C LTDB ST GT-N Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB GF I²t ON or OFF GFDB I ext. RELT Measurement unit (1) RELT Instantaneous + Modbus Communication + Zone Selective Interlock on I ext., ST & GF functions GT-Rating Plug Required for all types GTG00K4-4SF 408816 GTG00K4T6SF 408818 E F 2 I t on Basic functionality STDB GF I2 t on GTPUNI 408860 I ext. GFDB X Extended functionality Extended functionality RELT (1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 A.13 EntelliGuard™ Trip Units - Factory mounted GT- H Basic functionality LT-C LTDB ST I2 t on STDB Designation Extended functionality GT-H Trip Unit with: LT-C 0,2- 1 x In =Ir -ORLT-F 0,2- 1 x in =Ir LTDB ST I2T ON or OFF STDB I RELT LT Band shape Choice (LTC or LTF) GTG00N9-5SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Cat. No. Ref. No. 408823 LT Band shape Choice (LTC or LTF) GTG00N9-8SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication 408863 LT Band shape Choice (LTC or LTF) GTG00N9-9SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication 408865 GT-Rating Plug Required for all types 408860 GT-H Trip Unit with: LT-C 0,2- 1 x In =Ir -ORLT-F 0,2- 1 x in =Ir LTDB ST I2T ON or OFF STDB GF sum. I2T ON or OFF -AND/ORGF CT I2T ON or OFF(2) GFDB I RELT LT Band shape Choice (LTC or LTF) GTG00N5-5SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous 408825 LT Band shape Choice (LTC or LTF) GTG00N5-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication 408833 LT Band shape Choice (LTC or LTF) GTG00N5-9SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous Profibus Communication 408841 GTG00N5T5SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous 408829 GTG00N5T8SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication 408837 LT Band shape Choice (LTC or LTF) GTG00N5T9SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication 408845 Required for all types 408860 Order codes I Extended functionality LT-F GTPUNI LTDB Intro RELTi Basic functionality A LT-C LTDB B ST I2 t on STDB GF I I2 t on C GFDB Extended functionality D LT-F LTDB E F RELTi X GT-Rating Plug (1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) The use of an interposing current transformer is required (supplied, mounted in device) A.14 GTPUNI EntelliGuard™ Trip Units - Factory mounted GT- H Basic functionality LT-C LTDB I2 t on STDB GF l ext. 2 I t on GFDB Extended functionality GT-H Trip Unit with: LT-C 0,2- 1 x In =Ir -ORLT-F 0,2- 1 x In =Ir LTDB ST I2T ON or OFF STDB GF sum. I2T ON or OFF(2) -AND/ORGF CT I2T ON or OFF GFDB I ext. RELT LT Band shape Choice (LTC or LTF) GTG00N7-5SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous 408827 LT Band shape Choice (LTC or LTF) GTG00N7-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication 408835 LT Band shape Choice (LTC or LTF) GTG00N7-9SF Dual GF Protection (Res./Sum or CT) Measurement Unit (1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication 408843 GTG00N7T5SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF ST & GF Measurement Unit (1) Data aquisition & Relay functionality RELT Instantaneous 408831 GTG00N7T8SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF ST & GF Measurement Unit (1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication 408839 LT Band shape Choice (LTC or LTF) GTG00N7T9SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF ST & GF Measurement Unit (1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication 408847 Required for all types 408860 Extended functionality LT-F LTDB RELTi GT-Rating Plug (1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) The use of an interposing current transformer is required (supplied, mounted in device) Cat. No. GTPUNI Ref. No. Electronic Trip Units ST Designation Intro A B C D E F X A.15 EntelliGuard™ Trip Units - Factory mounted GT- H Basic functionality LT-C LTDB ST I2 t on STDB GF l ext. 2 Order codes I t on Intro GFDB Designation Extended functionality GT-H Trip Unit with: LT-C 0,2- 1 x In =Ir -ORLT-F 0,2- 1 x In =Ir LTDB ST I2T ON or OFF STDB GFA(2) sum. I2T ON or OFF -AND/ORGFA(2) CT I2N ON or OFF(3) GFDB I or I ext. RELT LT Band shape Choice (LTC or LTF) GTG00N6-5SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous With standard Instaneous Idem with Extended Instananeous GTG00N8-5SF 408826 LT Band shape Choice (LTC or LTF) GTG00N6-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8-8SF 408834 Extended functionality LT Band shape Choice (LTC or LTF) GTG00N6-9SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8-9SF LTDB RELTi LT Band shape Choice (LTC or LTF) GTG00N6T5SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous With standard Instaneous Idem with Extended Instananeous GTG00N8T5SF LT Band shape Choice (LTC or LTF) GTG00N6T8SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T8SF B C D E A.16 408828 408836 GT-Rating Plug 408842 408844 408830 408832 408838 408840 LT Band shape Choice (LTC or LTF) GTG00N6T9SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T9SF 408848 Required for all types 408860 (1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) Does NOT trip the associated EntelliGuard™ Breaker, BUT produces an Alarm signal (3) The use of an interposing current transformer is required (supplied, mounted in device) X Ref. No. LT-F A F Cat. No. GTPUNI 408846 EntelliGuard™ Internal Accessories - Factory mounted For field mounted variants see page A.20 & A.21 Motor Operators and Closing Coils(4) Motor Operator Type 1 Ref. No. Cat. No. Ref. No. GM01024D GM01048D GM01060D GM01110D GM01250D GM01048A GM01120A GM01240A GM01400A GM01440A 407700 407702 407704 407706 407708 407710 407712 407714 407716 407718 GM02024D GM02048D GM02060D GM02110D GM02250D GM02048A GM02120A GM02240A GM02400A GM02440A 407725 407727 407729 407731 407733 407735 407737 407739 407741 407743 GCCN024D GCCN048 GCCN060D GCCN120 GCCN240 GCCN277 GCCN400A GCCN440A Ref. No. Comm. Closing Coil(1) Closing Coil 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC Cat. No. GCCC024D GCCC048 GCCC060D GCCC120 GCCC240 GCCC277 GCCC400A GCCC440A 407861 407863 407865 407867 407869 407870 407877 407878 407836 407838 407840 407842 407844 407849 407852 407853 Releases Undervoltage 24V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC GUVT024D GUVT048 GUVT060D GUVT120 GUVT240 GUVT277 GUVT400A GUVT440A 407795 407797 407799 407801 407803 407805 407807 407809 Shunt GSTR024D GSTR048 GSTR060D GSTR120 GSTR240 GSTR277 GSTR400A GSTR440A Network Interlock 407770 407772 407774 407776 407778 407780 407782 407784 GNTK120 GNTK240 407753 407754 Delivered as standard option in all EntelliGuard™ breakers & Isolators(3) GAS6 407887 GAS5 407886 GAS8 407888 GBAT1 407891 A C Bell Alarm Contacts 1 Changeover Intro B Auxiliary Contacts Power Rated 3NO & 3NC Power Rated 8NO & 8NC Power Rated 3NO & 3NC + signal rated 2NO & 2NC Power Rated 4NO & 4NC + signal rated 4NO & 4NC Internal Accessories 24-30V DC 48V DC 60V DC 110-130V DC 220-250V DC 48V AC 110-130V AC 220-240V AC 380-400V AC 440V AC Motor Operator Type 2 & 3 Cat. No. D E Indication Contacts Power rated wired through sec. Discon. CC/CCC/UVT/STR Release indicator 1NO Breaker Ready to Close indic.(2) 1NO GCSP1 407895 GRTC1 407897 Signal rated wired through sec. Discon. GRTC2 407899 Signal rated wired Trip Unit (comm.) GCSP2 407896 GRTC3 407894 F X Position Indication Contacts Cassette Power rated on Cassette 1 Changeover per position 2 Changeovers per position GCPS1 GCPS2 407922 407923 (1) Designed to be accessed through the Trip Unit communication option (Modbus or Profibus). Up to a voltage rating of 277V a extra coil operating/ON push button is mounted on the Breaker front facia. (2) Not available as field mountable accessory (3) Device code GAS3 407885. (4) Motor Spring charged indication contact supplied with Motor Operator A.17 EntelliGuard™ Internal Accessories - Factory mounted For field mounted variants see page A.20 & A.21 Locking Mechanisms(1) Ronis Mounted on Breaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The Castell device 1 Mounted on Cassette. (2 devices for 2 locks are possible) Castell Profalux Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. GBRON 407971 GBCAS 407970 GBPRO 407978 GCRON 407976 GCPRO 407980 GMCN 408035 Order codes Operation Intro A Front Fascia of Breaker Counter; number of Operations Pre-assembled interlocks for cables(2) Interlock Scheme Type A B C B D C Brk. 1 Brk. 2 OFF ON OFF OFF ON OFF OFF OFF ON OFF OFF ON OFF OFF ON OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON ON OFF OFF OFF OFF OFF ON Fixed Pattern Brk. 3 Cat. No. Ref. No. Draw-out Cat. No. Ref. No. For Each Breaker GI2FAD 407900 For Each Breaker GI2WAD 407901 OFF OFF OFF ON OFF OFF For Each Breaker GI3FB 407902 For Each Breaker GI3WB 407903 ON OFF OFF ON ON OFF OFF ON ON OFF For Each Breaker GI3FC 407904 For Each Breaker GI3WC 407905 For Brk.1 & 3 GI2FAD 407900 For Brk.1 & 3 GI2WAD 407901 For Brk. 2 GI3FDT 407906 For Brk. 2 GI3WDT 407907 (1) For the separately available locks see page A.21, Kirk Lock version available on request (2) The kits must be ordered complete with a breaker. To allow for installation and transport each kit is supplied as a field mountable unit customized for use with the ordered draw-out breaker cassette or a fixed pattern breaker. For the associated cables see page. A.22 D Internal Accessories - Factory mounted E F X A.18 Maximum amount of installable internal accessories See page A.21. EntelliGuard™ Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro A B C D E F X A.19 EntelliGuard™ Internal Accessories - Field mountable For factory mounted variants see page A.17 & A.18 Motor Operators and Closing Coils Motor Operator envelope 1 Motor Operator envelope 2 & 3 Order codes 24-30V DC 48V DC 60V DC 110-130V DC 220-250V DC 48V AC 110-130V AC 220-240V AC 380-400V AC 440V AC Intro Ref. No. Cat. No. Ref. No. 407701 407703 407705 407707 407709 407711 407713 407715 407717 407719 GM02024DR GM02048DR GM02060DR GM02110DR GM02250DR GM02048AR GM02120AR GM02240AR GM02400AR GM02440AR 407726 407728 407730 407732 407734 407736 407738 407740 407742 407744 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC GCCN024DR GCCN048R GCCN060DR GCCN120R GCCN240R GCCN277R GCCN400AR GCCN440AR GCCC024DR GCCC048R GCCC060DR GCCC120R GCCC240R GCCC277R GCCC400AR GCCC440AR 407860 407862 407864 407866 407868 407871 407876 407879 Releases Undervoltage 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC GUVT024DR GUVT048R GUVT060DR GUVT120R GUVT240R GUVT277R GUVT400AR GUVT440AR 407796 407798 407800 407802 407804 407806 407808 407810 Power Rated 3NO & 3NC (Delivered as standard option in all EntelliGuard™ breakers & Isolators) Power Rated 8NO & 8NC Power Rated 3NO & 3NC + Signal Rated 2NO & 2NC Power Rated 4NO & 4NC + Signal Rated 4NO & 4NC GAS3R 407880 GAS6R GAS5R 407882 407881 GAS8R 407883 1 Changeover GBAT1R 407889 Shunt GSTR024DR GSTR048R GSTR060DR GSTR120R GSTR240R GSTR277R GSTR400AR GSTR440AR 407771 407773 407775 407777 407779 407781 407783 407785 Auxiliary Contacts C D Bell Alarm Contacts E Indication Contacts F CC/CCC/UVT/STR Release indicator Power rated wired through sec. Discon. Signal rated wired Trip Unit (comm.) GCSP1R GCSP2R 407915 407916 X Position Indication Contacts Cassette Power rated on Cassette 1 Changeover per position 2 Changeovers per position GCPS1R GCPS2R 407924 407925 (1) Designed to be accessed through the Trip Unit communication option (Modbus or Profibus). Up to a voltage rating of 277V a extra coil operating/ON push button is included in the kit for mounting on the Breaker front facia. A.20 Cat. No. Ref. No. Comm. Closing Coil(1) Closing Coil A B Cat. No. GM01024DR GM01048DR GM01060DR GM01110DR GM01250DR GM01048AR GM01120AR GM01240AR GM01400AR GM01440AR 407835 407837 407839 407841 407843 407850 407851 407854 EntelliGuard™ Internal Accessories - Field mountable For factory mounted variants see page A.17 & A.18 Locking Mechanisms(1) Ronis Castell Profalux Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Mounted on Breaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The Castell device 1 Mounted on Cassette (2 devices for 2 locks are possible) GBRONR 407968 GBCASR 407967 GBPROR 407979 GCRONR 407974 GCPROR 407981 Ronis 1104 B Lock (2) Profalux B204Y Lock (2) Castell FS1 lock/K4 key (2) GRON 407985 GPRO 407987 Associated Locks(2) GCAS 407986 Operation Front Fascia of Breaker Counter; number of Operations GMCNR 408033 Internal Accessories Cat. No. Intro (1) Kirk Lock version available on request (2) Not available as Factory Mounted accessory A Internal Accessories - Field mountable Maximum amount of installable internal accessories Motor Operator type 1 or 2 Closing Coil or Command Closing Coil Undervoltage Release(3) Shunt Release Network Interlock Release Auxiliary Contacts Power NO + NC Auxiliary Contacts Hi-Fidelity NO+NC Bell Alarm contacts Signaling Contacts Releases indic. Power Signaling Contacts Releases indic. HI.Fid. Breaker ready to close indication Breaker Spring Charged indication Position Indication Contacts (per Pos.) Earthing Device Locking Mechanism Breaker Locking Mechanism Cassette B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 6 6 6 6 4 4 4 4 3 3 3 3 2 2 2 2 0 0 0 0 0 0 0 0 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 3 3 3 3 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 2 2 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 2 2 2 2 1 1 1 1 2 2 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 C D E F X (3) TDM module (Time delay module) is mounted externally to the breaker A.21 EntelliGuard™ Internal Accessories - Field mountable Not available in a factory mounted variant Field mountable cables for interlocking of breakers (1) Interlock Scheme Interlock Type A B C Order codes D Time delay module for UVR release TDM 60V DC 110-130V DC 220-240V DC 250V DC 48V AC 110-130V AC 220-240V AC 250-277V AC 380- 415V AC 440V AC Intro No. of Cables Needed 1 cable per breaker, choose length as indicated 1 cable per breaker, choose length as indicated 1 cable per breaker, choose length as indicated Brk's 1 and 3: 1 cable per breaker, choose length as indicated Brk. 2: 2 cables per breaker, choose length as indicated Cat. No. Ref. No. GTDM060D GTDM120D GTDM240D GTDM250D GTDM048A GTDM120A GTDM240A GTDM277A GTDM400A GTDM440A 407817 407819 407821 407823 407816 407818 407820 407822 407824 407825 Cable length 1 metre Cable length 1,6 metre Cable length 2 metre Cable length 2,5 metre Cable length 3 metre Cable length 3,5 metre Cable length 4 metre Cat. No. Ref. No. Breaker Earthing Device for Service 3 pole EntelliGuard™ type 1 Maximum 1600A Maximum 2000A EntelliGuard™ type 2 Maximum 4000A EntelliGuard™ type 3 Maximum 6400A A B GT- Accessories C D 4 pole G16H4ED G20H4ED 407930 407932 G16H6ED G20H6ED 407931 407933 G40M4ED 407934 G40M6ED 407935 G64M4ED 407936 G64M6ED 407937 Conditioning Power Supply 1 phase 220-230V(2) Conditioning Power Supply 1 phase 380-400V(2) Conditioning Power Supply 1 phase 240-250/277-290/415V(2) Conditioning Power Supply 1 phase 660-690V(2) Power Supply - Input 100-240V AC or 100-353V DC Output 24V DC 0.6 Amps(3) GMPU1 GMPU2 GMPU3 GMPU4 GAPU 408790 408791 408792 408793 408789 Trip unit, sealable transparent front cover GTUS 408046 Trip Unit Battery Tester and Set up unit GTUTK20 407999 Wall Mounting Brackets for Env. 1 & 2 GFMTG 408085 Designation E F X Wall mounting Brackets (1) See for associated breaker and or cassette mounted kits page A.18 (2) Obligatory when a fully functioning measurement unit is required (3) For GF settings below 0,2 x In this aux. supply is needed A.22 Cat. No. Ref. No. GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 407990 407991 407992 407993 407994 407995 407996 EntelliGuard™ Installation Accessories Not available in a factory mounted variant Operation Ref. No. Front Fascia of Breaker Padlocking device for Pushbuttons GPBD 408040 Operation Indicators Contact Wear Indicator env. 1-3 GCNTW 408036 Cassette Mis insertion device GREPM 408041 Door Flange fixed all types (1) Door Flange draw-out all types (1) GDPRF GDPRW 408025 408026 Door Escutcheon IP54 G54DR 408038 Door Interlock on LEFT Door Interlock on RIGHT GLHD GRHD 408039 408042 Door Flanges & Interlocks Installation Accessories Cat. No. Intro A B Lifting Breakers(2) Lifting beam suited for use with envelope 1 & 2 GLB1 Lifting beam suited for use with envelope 3 GLB3 Set of 9 phase seperators for 1000V applications(3) GJP 408045 C 408049 D Phase seperators 408057 E F (1) Is a spare, these devices are always supplied with the standard devices (2) Designed for use with commercially available lifting equipment. (3) Universal set including 3 pcs for envelope 1 & 2 fixed, 3 pcs. for envelope 1 & 2 draw-out and 3 pcs for envelope 3. X A.23 EntelliGuard™ Sensors for Trip Units For use with Ground fault Residual (sum) protection Rogowski coils: Order codes Envelope 1 400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A B C D E F X A.24 Ref. No. Cat. No. Ref. No. G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNRC 408000 408001 408002 408003 408004 408005 408006 G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNRC G25MNRC G32LNRC G40LNRC 408000 408001 408002 408003 408004 408005 408006 408162 408186 408187 Envelope 3 Cat. No. Ref. No. G32LNRC G40LNRC G50LNRC G64LNRC 408186 408187 408188 408189 Sensors for Trip Units For use with Ground fault protection, Source Ground Return method Earth leg Current Transformers - Kit includes 1 Current Transformer. An interposing current transformer is also required (supplied with Trip Unit) Intro A Envelope 2 Cat. No. Envelope 1 400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A Envelope 2 Cat. No. Ref. No. Cat. No. Ref. No. G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G20HNCT 408300 408301 408302 408303 408304 408305 408006 G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G20HNCT G25MNCT G32LNCT G40LNCT 408300 408301 408302 408303 408304 408305 408006 408322 408331 408332 Envelope 3 Cat. No. Ref. No. G32LNCT G40LNCT G50LNCT G64LNCT 408331 408332 408333 408334 EntelliGuard™ Cassettes for use with Breakers & Isolators in Draw-out pattern; Field mountable - References apply for Cassettes separately supplied for use with Breakers or Isolator - With Connection modes as indicated in left column - Each cassette is supplied with safety shutters Cassettes for Draw-out Pattern; fixed portion only Universal Rear Connections 4 pole(1) 3 pole Cat. No. Ref. No. Cat. No. Ref. No. Cassette for envelope 1 400 - 1600A GG, GJ & GW type S 400 - 1600A GG, GJ & GW type N & H 2000A GG, GJ & GW type S, N & H GG16S2UR GG16H2UR GG20H2UR 407617 407612 407622 GG16S5UR GG16H5UR GG20H5UR 407619 407615 407625 Cassette for envelope 2(2) 400 - 2000A GG, GJ & GW type N, E & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M GG20M2UR GG25M2UR GG32M2UR GG40M2UR 407632 407642 407652 407666 GG20M5UR GG25M5UR GG32M5UR GG40M5UR 407635 407645 407656 407670 GG64L2UR 407686 GG64L5UR 407688 Remark: Each cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. Cassette for envelope 3(3) 3200 - 6400A(1) GG & GJ type G, M & L Sensors & Cassettes Rating (A) Suited for use with EntelliGuard™ -G types Intro Vertical rear Connections Cassette with dual vertical clusters and connection pads for limited de-rating envelope 2 3200A GH, GK, GJ & GZ type N.H & M 4000A GH, GK, GJ & GZ type N.H & M GH32M2VR GH40M2VR 408254 408267 GH32M5VR GH40M5VR 408255 408268 A B Front access Connections Cassette for envelope 1 400 - 1600A GG, GJ & GW type S 400 - 1600A GG, GJ & GW type N & H 2000A GG, GJ & GW type S, N & H Cassette for envelope 2 400 - 2000A GG, GJ & GW type E, N, H & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M GG16S2FR GG16H2FR GG20H2FR 407627 407610 407620 GG16S5FR GG16H5FR GG20H5FR 407629 407613 407623 C D GG20M2FR GG25M2FR GG32M2FR GG40M2FR (1) 4th pole on Left. (2) Cassettes for envelope 2 are limited to a current of 3200A when connected in horizontal mode Connected in vertical mode a 4000A rating is achieved (3) The Cassette for envelope 3 is limited to a current of 5000A when connected in horizontal mode Connected in vertical mode it has a rating of 6400A. This cassette type is NOT depicted here 407630 407640 407650 407658 GG20M5FR GG25M5FR GG32M5FR GG40M5FR 407633 407643 407654 407668 E F X A.25 EntelliGuard™ Field Mounted (spare) Trip Units Always specify Nominal current and Breaker serial Number on Ordering GT- E Basic functionality LT-C LTDB ST Designation Extended functionality GT-E Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB None GTG00K1-SR Cat. No. Ref. No. 408798 GT-Rating Plug Required for all types GTPUNI 408860 GT-E Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB None GTG00K2-SR 408802 GT-Rating Plug Required for all T types GTPUNI 408860 GT-S Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB I None GTG00K9-SR 408811 GT-Rating Plug Required for all types GTPUNI 408860 GT-S Trip Unit LT-C 0,2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB I Modbus Communication GTG00K4-2SR 408809 GT-Rating Plug Required for all types GTPUNI 408860 GT-N Trip Unit with: LT-C 0,2 -1 x In = Ir LTDB ST I²t ON or OFF STDB I RELT Measurement unit (1) RELT Instantaneous GTG00K9-4SR 408821 GT-Rating Plug Required for all types GTPUNI 408860 2 I t on Order codes STDB LT-C LTDB ST I2 t on STDB GF 2 I t on Intro GFDB GT- S LT-C A LTDB B ST I2 t on STDB I C LT-C D LTDB E ST I2 t on STDB GF 2 I t on Ii GFDB F GT- N X LT-C LTDB ST I2 t on STDB I Extended functionality RELT A.26 EntelliGuard™ Field Mounted (spare) Trip Units Always specify Nominal current and Breaker serial Number on Ordering GT- N (continued) Basic functionality LT-C LTDB I2t on STDB GF I2t on Ihi Extended functionality Cat. No. Ref. No. GT-N Trip Unit LT-C 0,2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB I ext. Measurement unit(1) Modbus Communication Zone Selective Interlock on ST, I & GF GTG00K4T6SR 408819 GT-Rating Plug Required for all types GTPUNI 408860 GT-H Trip Unit with: LT-C 0,2 -1 x In = Ir -ORLT-F 0.2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF or GFA(2) sum. I2T ON or OFF -AND/ORGFA(2) CT I2N ON or OFF(3) GFDB I or I ext. RELT LT Band shape Choice (LTC or LTF) GTG00N5T8SR Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N7T8SR GFDB GT- H LTDB ST 2 I t on STDB GF Ihi 2 I t on GFDB Extended functionality LT-F LT Band shape Choice (LTC or LTF) GTG00N5T9SR Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication With standard Instaneous Idem with Extended Instananeous GTG00N7T9SR 408849 408851 408853 408855 LT Band shape Choice (LTC or LTF) GTG00N6T8SR Dual GF Alarm (Res./Sum or CT) Zone Selective Interlock on ST, I & GFA Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T8SR 408850 LT Band shape Choice (LTC or LTF) GTG00N6T9SR Dual GF Alarm (Res./Sum or CT) Zone Selective Interlock on ST, I & GFA Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Profibus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T9SR 408854 GT-Rating Plug Required for all types GTPUNI 408860 GT Trip Unit with NO protection (For Non Automatic types) G3G00KA-SR 408796 (1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) Does NOT trip the associated EntelliGuard™ Breaker, BUT produces an Alarm signal (3) The use of an interposing current transformer is required (supplied with Trip Unit) Intro A LTDB RELTi Electronic Trip Units ST Designation B C 408852 D E 408856 F X A.27 EntelliGuard™ Spare Parts Breaker Arc Chutes Envelope 1 Envelope 2 Envelope 3 Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Arc Chute for 1 pole G20HCHT 408102 G40MCHT 408131 G64LCHT 408144 Set for 1pole S & N types Set for 1pole H type Set for 1pole E & N types Set for 1pole H & M types Set for 1pole L type G20NARC G20HARC 408104 408098 G40NARC G40MARC 408172 408169 G64LARC 408193 System with Interlock 3 pole System with Interlock 4 pole G20H2SSL G20H5SSL 407606 407607 G40M2SSL G40M5SSL 407636 407637 G64L2SSL G64L5SSL 407679 407680 Spare Racking Handle GRHN 408043 GRHN 408043 GRHN 408043 Front Facia Set of 4 spare Lock cams for use with Ronis 1104 locks GFA4 GRONCS 408028 407984 GFA4 GRONCS 408028 407984 GFA4 GRONCS 408028 407984 G13HCLS G16HCLS G20HCLS 408097 408100 408103 G20MCLS G25MCLS G32MCLS G40MCLS 408106 408109 408117 408120 G50LCLS G64LCLS 408145 408148 Order codes Breaker Fixed Arcing Contacts Cassette Shutters Cassette Racking Handle Intro A Breaker front facia part(1) B C Cassette Cluster Contacts Sets per pole Current Rating 400-1250A Current Rating 1600A Current Rating 2000A Current Rating ≥2000A Current Rating 2500A Current Rating 3200A Current Rating 4000A Current Rating 5000A Current Rating 6400A D E F X Breakers and Cassette Spare Auxiliary Disconnect plugs Set of Universal Cluster Pliers GUNI 408047 GUNI 408047 GUNI 408047 For Fixed Breaker 1 39 pole set For Fixed Breaker 1 78 pole set For Draw-out Breaker 1 39 pole set (two can be mounted) GSFDTR1 408052 GSFDTR1 408052 GSFDTR1 408052 GSFDTR2 408030 GSFDTR2 408030 GSFDTR2 408030 GSDWTR 408054 GSDWTR 408054 GSDWTR 408054 G3G00KA-SR 408796 GT Trip Unit with NO protection (Suited for Non Automatic type) (1) The original breaker serial number must be indicated on ordering A.28 EntelliGuard™ Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro A B C D E F X A.29 EntelliGuard™ Global Catalogue number structure - Breaker - Codes built in the indicated manner can be used as an alternative ordering method - The breaker and its operation mode (Manual or Electrical) 1st digit 3rd & 4th digit 6th digit 7th digit A product belonging to the EntelliGuard™ breaker line Nominal current rating of the product Fixed Pattern or Draw-out Pattern moving portion and Number of poles Electrically or Hand Operated Order codes 400A Intro 04 3 pole Fixed Pattern 4 Electrical at: 630A 07 800A 08 3 pole Draw-out Moving Portion 1 1000A 10 4 pole Fixed Pattern 6 1250A 13 1600A 16 2000A 20 48V AC G 2500A 25 110-130V AC H 3200A 32 230-240V AC J 4000A 40 277V AC K 5000A 50 380-415V AC M 6400A 64 440V AC N Manual X 4 pole Draw-out Moving Portion 3 24V DC A 48V DC B 60V DC C 110-130V DC E 220-250V DC F A B G G 1 3 H 4 X X C Product Type D E F Circuit Breaker G Circuit Breaker with reduced de-rating H Non Automatic (Switch) no MCR J Non Automatic (Switch) with MCR W Non Automatic (Switch) 100% rated no MCR K Non Automatic (Switch) 100% rated with MCR Z Interruption / short-circuit withstand rating of the product Icu = Ics Icw Code 50kA 50kA S 65kA 65kA N 85kA 65kA H 85kA 85kA E 100kA 85kA M 100kA 100kA G 150kA 100kA L X 5th digit (1) Is supplied with a Push Button for Local Breaker operation (fits on breaker front facia) A.30 Standard Closing Coil Command Closing Coil(1) 24V DC A M 40-48VDC 48V AC B P 60V DC D Q 110-130V AC-DC E R 220-240V AC-DC G T 250V DC 277V AC H U 380-415V AC K W 440V AC L Y Manual X X If Electrically Operated add 1 Closing Coil by indicating voltage rating code. If manual use an X as indicated For an overview of the valid combinations indicating the available options see page A.34 2nd digit Voltage Rating 8th digit EntelliGuard™ Global Catalogue number structure - Breaker - Codes built in the indicated manner can be used as an alternative ordering method - Breaker mounted accessories and Trip Unit 11th digit A 40-48VDC 48V AC B 60V DC C 110-130V AC-DC E 220-240V AC-DC G 250V DC 277V AC H 380-415V AC K 440V AC L Network Interlock 1 None X 8 Bell Alarm Switch & Operations Counter UVR code Code to be added A 1 Mechanical Operations Counter 40-48VDC 48V AC C 3 60V DC D 4 110-130V AC-DC E 5 Bell Alarm 1NO & Mechanical Operations counter Ready to Close contact 1 NO Power Rated on Secondary terminals Ready to Close contact 1 NO Signal Rated on Secondary terminals Ready to Close contact 1 NO Signal Rated connected through Trip Unit 220-240V AC-DC G 7 250V DC 277V AC H 8 380-415V AC K W 440V AC L Y None X X A Bell Alarm 1 NO 24V DC X E F B K L M C G H J X X X X 2 3 None 2 D 1 Add a 2nd or UVR Shunt Release by indicating the voltage rating code. if not needed use an X as indicated. Add 1st Shunt Release by indicating voltage rating code. if not needed use an X as indicated, or '1' for a network Interlock 1 Shunt code Ready to Close contact 1 NO SIgnal Rated connected Through Trip Unit 24V DC Voltage Rating Ready to Close contact 1 NO SIgnal Rated on Secondary terminals Code Ready to Close contact 1 NO Power Rated on Secondary terminals 2nd Shunt or UVR Release Voltage Rating No other contacts installed Shunt Release 13th digit X Catalogue number structure 9th digit Intro A B C Auxiliary Switches & Configuration Code to be added 3NO+3NC (Power Rated)(1) 2 24V DC 1 8NO+8NC (Power Rated) 4 40-48VDC 48V AC 3 3NO/3NC (Power Rated) + 2NO/2NC (Signal) 6 4NO/4NC (Power Rated) + 4NO/4NC Signal) 8 60V DC 4 110-130V AC-DC 5 220-240V AC-DC 7 250V DC 277V AC 8 380-415V AC W 440V AC Y None X Add 1st UVR release by using the indicated code. If a ‘1’ is chosen as a 9th digit the use of a Network Interlock with equivalent voltage is assumed. The use of an X indicates no Release installed. 10th digit No other contacts installed Code Voltage Rating A B C D E F G H S T J K L M N P Q R U V Coil Signaling Contact Power (1 NO on Secondary Disconnect) - Close Coil or command close coil Coil Signaling Contact High Fidelity through Trip Unit Close Coil or command close coil Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 1st Shunt Coil Signaling Contact High Fidelity through Trip Unit - 1st Shunt Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 1st UVR Coil Signaling Contact High Fidelity through Trip Unit - 1st UVR Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 2nd ST or 2nd UVR through Trip Unit - 2nd ST or 2nd UVR Coil Signaling Contact High Fidelity Coil Signaling Contact Power (1 NO on Secondary Disconnect) - All installed devices CC/CCC, ST, or UVR Coil Signaling Contact Hight Fidelity (1 NO - Through Trip Unit) - All installed devices. CC/CCC, ST, or UVR Undervoltage Release (2) D E F X Add one of the chosen combinations by using one of the indicated codes. 12th digit (1) Each standard breaker or Isolator is normally supplied with 3 NO+3NC Aux. contacts (option 2) A.31 EntelliGuard™ Global Catalogue number structure - Breaker - Codes built in the indicated manner can be used as an alternative ordering method - Breaker mounted accessories and Trip Unit 14th digit 16th, 17th & 18th digit Order codes Factory Installed prevision to mount a Key lock on the breakers Defines Installed GT type Electronic Trip Unit Basic type For Ronis or Profalux Key lock R GT-E with Ammeter For Kirk Key lock K GT-S with Ammeter Optional Communication For Castell type Key lock C No prevision for Key lock X Code E S GT-N with Measurement Optional Communication N Intro A B G 19th digit X H Functionality Code LT, LTDB. ST, STDB 01 LT, LTDB. ST, STDB, GF, GFDB 02 LT, LTDB. ST, STDB, I 06 LT, LTDB. ST, STDB, I, GF, GFDB LT, LTDB. ST, STDB, I, GF, GFDB * Modbus communication LT, LTDB. ST, STDB, HI, GF, GFDB LT, LTDB. ST, STDB, HI, GF, GFDB * Modbus communication LT, LTDB. ST, STDB, I 07 LT, LTDB. ST, STDB, I, GF, GFDB LT, LTDB. ST, STDB, I, GF, GFDB + ZSI on ST and GF + Modbus communication LT, LTDB. ST, STDB, HI, GF, GFDB LT, LTDB. ST, STDB, HI, GF, GFDB + ZSI on ST and GF + Modbus communication 10 09 03 05 08 D E F X Mechanical Interlock Type A A.32 GT-H 1 Mechanical Interlock Type B 2 Mechanical Interlock Type C 3 Mechanical Interlock Type D 4 No prevision for Breaker interlock X 15th digit Code With Measurement, Relaying and Wave form capture Optional, Modbus or Profibus Communication H A English Dutch French B English Spanish Portuguese E English Russian Italian C 04 12 23 B Defines Installed GT type Electronic Trip Unit Basic type English German Polish 11 C Factory Installed prevision to mount a Cable interlock between breakers Defines instruction manual language Functionality Code LT+ (C+F),LTDB,ST,STDB.GF+EF,HI 13 LT+ (C+F),LTDB,ST,STDB.GF+EF,HI + Modbus Communication 14 LT+ (C+F),LTDB,ST,STDB.GF+EF,HI + Profibus Communication 15 LT+ (C+F),LTDB,ST,STDB.GF+EF,HI ZSI on ST, GF & HI 16 Functionality Code LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I + Modbus Communication 28 LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I + Profibus Communication 29 LT+(C+F),LTDB,ST,STDB.GFA+EFA,& I 30 31 LT+ (C+F),LTDB,ST,STDB.GF+EF,HI ZSHI on ST, GF & HI + Modbus Communication 17 LT+(C+F),LTDB,ST,STDB.GFA+EFA, I + Modbus Communication + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI 18 LT+(C+F),LTDB,ST,STDB.GFA+EFA, I + Profibus Communication 32 LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI + Modbus Communication 19 LT+C+F),LTDB,ST,STDB. GFA+EFA,IZSI on ST, GFA & I 33 LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI + Profibus Communication 20 34 LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI LT+(C+F),LTDB,ST,STDB. GFA+EFA,IZSI on ST, GFA & I + Modbus Communication 21 LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI + Modbus Communication 35 22 LT+(C+F),LTDB,ST,STDB.GFA+EFA, I, ZSI on ST, GFA & I + Profibus Communication LT+ (C+F),LTDB,ST,STDB.I 23 LT+ (C+F),LTDB,ST,STDB.I + Modbus Communication 36 LT+ (C+F),LTDB,ST,STDB.GF+EF,I 24 LT+ (C+F),LTDB,ST,STDB.GF+EF,I + Modbus Communication LT+ (C+F),LTDB,ST,STDB.I + Profibus Communication 37 25 LT+ (C+F),LTDB,ST,STDB.GF+EF,I + Profibus Communication LT+(C+F),LTDB,ST,STDB.GF+EF,HI + Profibus Communication 38 26 LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I 27 LT+C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI + Profibus Communication 39 EntelliGuard™ Global Catalogue number structure - Cassette - Codes built in the indicated manner can be used as an alternative ordering method - Cassettes supplied together with the breaker 3rd & 4th digit 6th digit 7th digit 9th digit A product belonging to the EntelliGuard™ breaker line Nominal current rating of the product Number of Poles of the Cassette Connection Mode Position Indication switches in Cassette 1600A 16 3 pole 2 2000A 20 4 pole 5 2500A 3200A U 25 Rear Universal, T stubs rotatable -Horizontal or Vertical busbars 32 Front Flat access F 4000A 40 6400A 64 Rear Horizontal busbars H Rear Vertical busbars V Set of 1 NO and 1NC contacts per Position 2 Set of 2 NO and 2NC contacts per Position 4 No Switches Mounted X Catalogue number structure 1st digit Intro A G G 13 H 2 U X X B X C Maximum interruption / short-circuit withstand rating of the Breaker used with the Cassette Suitable for: Standard Circuit Breaker or standard Non Automatic type G Icu = Ics Icw Code 50kA 50kA S 85kA Circuit Breaker or standard Non Automatic type with reduced derating H Delivered mounted with breaker or separately(2) Mounted with breaker Delivered as separate component M Factory Installed prevision to mount a Key lock on the cassette For 1 Ronis Key lock R R For 2 Ronis Key locks S For 1 Profalux Key lock P 65kA H 100kA 85kA M For 2 Profalux Key locks Q 150kA 100kA L No Lock Prevision mounted X D E F 2nd digit 5th digit 8th digit 10th digit(1) X For an overview of the valid combinations indicating the available options see page A.34 (1) 11 and 12th digit reserved for future use (2) The 10th and 11th digit are reserved for future expansion of the ordering code system (An X or - is used as temporary filler) A.33 EntelliGuard™ Valid Catalogue number combinations Factory mounted: Available standard Breaker & Cassette types Order codes 3 pole Breakers in Fixed Pattern Intro A B C D E F X A.34 4 pole Breakers in Fixed Pattern 3 pole Breakers; Draw-out Portion only 3 pole Breakers; Standard Cassette for Draw-out portion Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page GG04E4 GG04H4 GG04M4 GG04N4 GG04S4 GG07E4 GG07H4 GG07M4 GG07N4 GG07S4 GG08E4 GG08H4 GG08M4 GG08N4 GG08S4 GG10E4 GG10H4 GG10M4 GG10N4 GG10S4 GG13E4 GG13H4 GG13M4 GG13N4 GG13S4 GG16E4 GG16H4 GG16M4 GG16N4 GG16S4 GG20E4 GG20H4 GG20M4 GG20N4 GG20S4 GG25H4 GG25M4 GG25N4 GG32G4 GG32H4 GG32L4 GG32M4 GG32N4 GG40G4 GG40H4 GG40L4 GG40M4 GG40N4 GG64L4 GG64M4 GG50L4 GG50M4 407003 407007 407011 407015 407019 407032 407036 407040 407044 407048 407062 407066 407070 407074 407078 407092 407096 407100 407104 407108 407122 407126 407130 407134 407138 407152 407156 407160 407164 407168 407192 407196 407200 407204 407208 407232 407236 407240 407252 407244 407254 407262 407266 407270 407280 407284 407288 407292 407322 407326 407302 407306 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 GG04E6 GG04H6 GG04M6 GG04N6 GG04S6 GG07E6 GG07H6 GG07M6 GG07N6 GG07S6 GG08E6 GG08H6 GG08M6 GG08N6 GG08S6 GG10E6 GG10H6 GG10M6 GG10N6 GG10S6 GG13E6 GG13H6 GG13M6 GG13N6 GG13S6 GG16E6 GG16H6 GG16M6 GG16N6 GG16S6 GG20E6 GG20H6 GG20M6 GG20N6 GG20S6 GG25H6 GG25M6 GG25N6 GG32H6 GG32G6 GG32L6 GG32M6 GG32N6 GG40G6 GG40H6 GG40L6 GG40M6 GG40N6 GG50L6 GG50M6 GG64L6 GG64M6 407004 407008 407012 407016 407020 407033 407037 407041 407045 407049 407063 407067 407071 407075 407079 407093 407097 407101 407105 407109 407123 407127 407131 407135 407139 407153 407157 407161 407165 407169 407193 407197 407201 407205 407209 407233 407237 407241 407245 407253 407255 407263 407267 407271 407281 407285 407289 407293 407303 407307 407323 407327 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 GG04E1 GG04H1 GG04M1 GG04N1 GG04S1 GG07E1 GG07H1 GG07M1 GG07N1 GG07S1 GG08E1 GG08H1 GG08M1 GG08N1 GG08S1 GG10E1 GG10H1 GG10M1 GG10N1 GG10S1 GG13E1 GG13H1 GG13M1 GG13N1 GG13S1 GG16E1 GG16H1 GG16M1 GG16N1 GG16S1 GG20E1 GG20H1 GG20M1 GG20N1 GG20S1 GG25H1 GG25M1 GG25N1 GG32G1 GG32H1 GG32L1 GG32M1 GG32N1 GG40G1 GG40H1 GG40L1 GG40M1 GG40N1 GG50L1 GG50M1 GG64L1 GG64M1 GH32H1 GH32M1 GH32N1 GH40H1 GH40M1 GH40N1 407001 407005 407009 407013 407017 407030 407034 407038 407042 407046 407060 407064 407068 407072 407076 407090 407094 407098 407102 407106 407120 407124 407128 407132 407136 407150 407154 407158 407162 407166 407190 407194 407198 407202 407206 407230 407234 407238 407250 407242 407248 407260 407264 407268 407278 407282 407286 407290 407300 407304 407320 407324 407346 407348 407350 407352 407354 407356 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.9 A.9 A.9 A.9 A.9 A.9 GG16H2FM GG16H2UM GG16S2FM GG16S2UM GG20H2FM GG20H2UM GG20M2FM GG20M2UM GG25M2FM GG25M2UM GG32M2FM GG32M2UM GG40M2FM GG40M2UM GG64L2UM GH32M2VM GH40M2VM 408200 408202 407626 407616 408210 408212 408222 408224 408234 408236 408245 408247 408257 408259 408281 408292 408294 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 EntelliGuard™ Valid Catalogue number combinations Factory mounted: Available standard Breaker, Cassette and Trip Unit types 4 pole Breakers; Standard Cassette for Draw-out portion Global Trip Units Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page GG04E3 GG04H3 GG04M3 GG04N3 GG04S3 GG07E3 GG07H3 GG07M3 GG07N3 GG07S3 GG08E3 GG08H3 GG08M3 GG08N3 GG08S3 GG10E3 GG10H3 GG10M3 GG10N3 GG10S3 GG13E3 GG13H3 GG13M3 GG13N3 GG13S3 GG16E3 GG16H3 GG16M3 GG16N3 GG16S3 GG20E3 GG20H3 GG20M3 GG20N3 GG20S3 GG25H3 GG25M3 GG25N3 GG32G3 GG32H3 GG32L3 GG32N3 GG40G3 GG40H3 GG40L3 GG40M3 GG40N3 GG50L3 GG50M3 GG64L3 GG64M3 GGM3M3 GH32H3 GH32M3 GH32N3 GH40H3 GH40M3 GH40N3 407002 407006 407010 407014 407018 407031 407035 407039 407043 407047 407061 407065 407069 407073 407077 407091 407095 407099 407103 407107 407121 407125 407129 407133 407137 407151 407155 407159 407163 407167 407191 407195 407199 407203 407207 407231 407235 407239 407251 407273 407249 407265 407269 407279 407283 407287 407291 407301 407305 407321 407325 407261 407347 407349 407351 407353 407355 407357 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.9 A.9 A.9 A.9 A.9 A.9 GG16H5FM GG16H5UM GG16S5FM GG16S5UM GG20H5FM GG20H5UM GG20M5FM GG20M5UM GG25M5FM GG25M5UM GG32M5FM GG32M5UM GG40M5FM GG40M5UM GG64L5UM GH32M5VM GH40M5VM 408203 408205 407628 407618 408213 408215 408225 408227 408237 408239 408249 408251 408261 408263 408283 408293 408295 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 GTG00K1-SF GTG00K2-SF GTG00K3-2SF GTG00K3-4SF GTG00K3-SF GTG00K3T6SF GTG00K4-2SF GTG00K4-4SF GTG00K4-SF GTG00K4T6SF GTG00K9-4SF GTG00K9-SF GTG00N5-5SF GTG00N5-8SF GTG00N5-9SF GTG00N5T5SF GTG00N5T8SF GTG00N5T9SF GTG00N6-5SF GTG00N6-8SF GTG00N6-9SF GTG00N6T5SF GTG00N6T8SF GTG00N6T9SF GTG00N7-5SF GTG00N7-8SF GTG00N7-9SF GTG00N7T5SF GTG00N7T8SF GTG00N7T9SF GTG00N8-5SF GTG00N8-8SF GTG00N8-9SF GTG00N8T5SF GTG00N8T8SF GTG00N8T9SF GTG00N9-5SF GTG00N9-8SF GTG00N9-9SF GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI 408800 408801 408807 408815 408805 408817 408808 408816 408806 408818 408813 408803 408825 408833 408841 408829 408837 408845 408826 408834 408842 408830 408838 408846 408827 408835 408843 408831 408839 408847 408828 408836 408844 408832 408840 408848 408823 408863 408865 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 A.12 A.12 A.12 A.13 A.12 A.13 A.12 A.13 A.12 A.13 A.13 A.12 A.14 A.14 A.14 A.14 A.14 A.14 A.16 A.16 A.16 A.16 A.16 A.16 A.15 A.15 A.15 A.15 A.15 A.15 A.16 A.16 A.16 A.16 A.16 A.16 A.14 A.14 A.14 A.12 A.12 A.12 A.12 A.12 A.13 A.13 A.13 A.14 A.14 A.15 A.16 Catalogue number combinations 4 pole Breakers; Draw-out Portion only Intro A B C D E F X A.35 EntelliGuard™ Valid Catalogue number combinations Order codes Factory mounted: Available standard Isolator & Cassette types Intro A B C D E F X A.36 3 pole Isolators; Draw-out Portion only 3 pole Isolators; Standard Cassette for Draw-out portion 3 pole Isolators in Fixed Pattern 4 pole Isolators in Fixed Pattern Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page GJ04S4 GJ07S4 GJ08S4 GJ10S4 GJ13S4 GJ16S4 GJ20S4 GJ25N4 GJ32L4 GJ32N4 GJ40L4 GJ40N4 GJ50L4 GJ64L4 GW04M4 GW04N4 GW07M4 GW07N4 GW08M4 GW08N4 GW10M4 GW10N4 GW13M4 GW13N4 GW16M4 GW16N4 GW20M4 GW20N4 GW25M4 GW32M4 GW40M4 407380 407400 407420 407440 407460 407480 407500 407520 407535 407539 407556 407560 407567 407577 408350 407376 408352 407396 408354 407416 408356 407436 408358 407456 408360 407476 408362 407496 408364 408366 408368 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 GJ04S6 GJ07S6 GJ08S6 GJ10S6 GJ13S6 GJ16S6 GJ20S6 GJ25N6 GJ32L6 GJ32N6 GJ40L6 GJ40N6 GJ50L6 GJ64L6 GW04M6 GW04N6 GW07M6 GW07N6 GW08M6 GW08N6 GW10M6 GW10N6 GW13M6 GW13N6 GW16M6 GW16N6 GW20M6 GW20N6 GW25M6 GW32M6 GW40M6 407381 407401 407421 407441 407461 407481 407501 407521 407536 407540 407557 407561 407568 407578 408351 407377 408353 407397 408355 407417 408357 407437 408359 407457 408361 407477 408363 407497 408365 408367 408369 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 GJ04S1 GJ07S1 GJ08S1 GJ10S1 GJ13S1 GJ16S1 GJ20S1 GJ25N1 GJ32L1 GJ32N1 GJ40L1 GJ40N1 GJ50L1 GJ64L1 GK32N1 GK40N1 GW04M1 GW04N1 GW07M1 GW07N1 GW08M1 GW08N1 GW10M1 GW10N1 GW13M1 GW13N1 GW16M1 GW16N1 GW20M1 GW20N1 GW25M1 GW32M1 GW40M1 GZ32H1 GZ40H1 407378 407398 407418 407438 407458 407478 407498 407518 407533 407537 407554 407558 407565 407575 407591 407595 408400 407374 408402 407394 408404 407414 408406 407434 408408 407454 408410 407474 408412 407494 408414 408416 408418 407589 407593 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 GG16H2FM GG16H2UM GG16S2FM GG16S2UM GG20H2FM GG20H2UM GG20M2FM GG20M2UM GG25M2FM GG25M2UM GG32M2FM GG32M2UM GG40M2FM GG40M2UM GG64L2UM GH32M2VM GH40M2VM 408200 408202 407626 407616 408210 408212 408222 408224 408234 408236 408245 408247 408257 408259 408281 408292 408294 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 EntelliGuard™ Valid Catalogue number combinations Factory mounted: Available standard Isolator & Cassette types 4 pole Isolators; Standard Cassette for Draw-out portion Cat. No Ref. No. Page Cat. No Ref. No. Page GJ04S3 GJ07S3 GJ08S3 GJ10S3 GJ13S3 GJ16S3 GJ20S3 GJ25N3 GJ32L3 GJ32N3 GJ40L3 GJ40N3 GJ50L3 GJ64L3 GK32N3 GK40N3 GW04M3 GW04N3 GW07M3 GW07N3 GW08M3 GW08N3 GW10M3 GW10N3 GW13M3 GW13N3 GW16M3 GW16N3 GW20M3 GW20N3 GW25M3 GW32M3 GW40M1 GZ32H3 GZ40H3 407379 407399 407419 407439 407459 407479 407499 407519 407534 407538 407555 407559 407566 407576 407592 407596 408401 407375 408403 407395 408405 407415 408407 407435 408409 407455 408411 407475 408413 407495 408415 408417 408418 407590 407594 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 GG16H5FM GG16H5UM GG16S5FM GG16S5UM GG20H5FM GG20H5UM GG20M5FM GG20M5UM GG25M5FM GG25M5UM GG32M5FM GG32M5UM GG40M5FM GG40M5UM GG64L5UM GH32M5VM GH40M5VM 408203 408205 407628 407618 408213 408215 408225 408227 408237 408239 408249 408251 408261 408263 408283 408293 408295 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 Catalogue number combinations 4 pole Isolators; Draw-out Portion only Intro A B C D E F X A.37 EntelliGuard™ Valid Catalogue number combinations Accessories, Factory and Field mountable Order codes Factory Mounted Accessories Intro A B C D E F X A.38 Field Mountable Alternative versions Accessories only available as Factory Mounted types Accessories only available in Field Mountable versions Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page GAS5 GAS6 GAS8 GBAT1 GBCAS GBPRO GBRON GCCC024D GCCC048 GCCC060D GCCC120 GCCC240 GCCC277 GCCC400A GCCC440A GCCN024D GCCN048 GCCN060D GCCN120 GCCN240 GCCN277 GCCN400A GCCN440A GCPRO GCPS1 GCPS2 GCRON GCSP1 GCSP2 GM01024D GM01048A GM01048D GM01060D GM01110D GM01120A GM01240A GM01250D GM01400A GM01440A GM02024D GM02048A GM02048D GM02060D GM02110D GM02120A GM02240A GM02250D GM02400A GM02440A GMCN GSTR024D GSTR048 GSTR060D GSTR120 GSTR240 GSTR277 GSTR400A GSTR440A GUVT024D GUVT048 GUVT060D GUVT120 GUVT240 GUVT277 GUVT400A GUVT440A 407886 407887 407888 407891 407970 407978 407971 407836 407838 407840 407842 407844 407849 407852 407853 407861 407863 407865 407867 407869 407870 407877 407878 407980 407922 407923 407976 407895 407896 407700 407710 407702 407704 407706 407712 407714 407708 407716 407718 407725 407735 407727 407729 407731 407737 407739 407733 407741 407743 408035 407770 407772 407774 407776 407778 407780 407782 407784 407795 407797 407799 407801 407803 407805 407807 407809 A.17 A.17 A.17 A.17 A.18 A.18 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.17 A.17 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 GAS5R GAS6R GAS8R GBAT1R GBCASR GBPROR GBRONR GCCC024DR GCCC048R GCCC060DR GCCC120R GCCC240R GCCC277R GCCC400AR GCCC440AR GCCN024DR GCCN048R GCCN060DR GCCN120R GCCN240R GCCN277R GCCN400AR GCCN440AR GCPROR GCPS1R GCPS2R GCRONR GCSP1R GCSP2R GM01024DR GM01048AR GM01048DR GM01060DR GM01110DR GM01120AR GM01240AR GM01250DR GM01400AR GM01440AR GM02024DR GM02048AR GM02048DR GM02060DR GM02110DR GM02120AR GM02240AR GM02250DR GM02400AR GM02440AR GMCNR GSTR024DR GSTR048R GSTR060DR GSTR120R GSTR240R GSTR277R GSTR400AR GSTR440AR GUVT024DR GUVT048R GUVT060DR GUVT120R GUVT240R GUVT277R GUVT400AR GUVT440AR 407881 407882 407883 407889 407967 407979 407968 407835 407837 407839 407841 407843 407850 407851 407854 407860 407862 407864 407866 407868 407871 407876 407879 407981 407924 407925 407974 407915 407916 407701 407711 407703 407705 407707 407713 407715 407709 407717 407719 407726 407736 407728 407730 407732 407738 407740 407734 407742 407744 408033 407771 407773 407775 407777 407779 407781 407783 407785 407796 407798 407800 407802 407804 407806 407808 407810 A.20 A.20 A.20 A.20 A.21 A.21 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.21 A.20 A.20 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 GI2FAD GI2WAD GI3FB GI3FC GI3FDT GI3WB GI3WC GI3WDT GNTK120 GNTK240 GRTC1 GRTC2 GRTC3 407900 407901 407902 407904 407906 407903 407905 407907 407753 407754 407897 407899 407894 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.17 A.17 A.17 A.17 A.17 G16H4ED G16H4FFI G16H6ED G16H4RVI G16H6FFI G16H6RVI G20H4ED G20H4FFI G20H4RVIn G20H6ED G20H6FFI G20H6RVIn G32M4FFI G32M4RVI G32M6FFI G32M6RVI G40M4ED G40M4FFI G40M4RVI G40M6ED G40M6FFI G40M6RVI G54DR G64L4RVI G64L6RVI G64M4ED G64M6ED GAPU GAS3R GCAS GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GCNTW GDPRF GDPRW GFMTG GJP GLHD GLB3 GLB1 GMPU1 GMPU2 GMPU3 GPBD GPRO GREPM GRHD GRON GRONCS GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM250D GTDM277A GTDM400A GTDM440A GTUS GTUTK20 407930 408060 407931 408058 408062 408082 407932 408061 408059 407933 408063 408083 408066 408070 408068 408071 407934 408067 408072 407935 408069 408074 408038 408073 408075 407936 407937 408789 407880 407986 407990 407991 407992 407993 407994 407995 407996 408036 408025 408026 408085 408057 408039 408049 408045 408790 408791 408792 408040 407987 408041 408042 407985 407984 407816 407817 407818 407819 407820 407821 407823 407822 407824 407825 408046 407999 A.22 A.6 A.22 A.6 A.6 A.6 A.22 A.6 A.6 A.22 A.6 A.6 A.6 A.6 A.6 A.6 A.22 A.6 A.6 A.22 A.6 A.6 A.23 A.6 A.6 A.22 A.22 A.22 A.20 A.21 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.23 A.23 A.23 A.6 A.23 A.23 A.23 A.23 A.22 A.22 A.22 A.23 A.21 A.23 A.23 A.21 A.28 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 EntelliGuard™ Valid Catalogue number combinations Accessories, Sensors, Cassettes, Trip Units ans Spares Separately available Standard Cassette for Draw-out portion Separately available ‘Plug & Play’ Trip Units Separately available Spare Parts Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page Cat. No Ref. No. Page G04HNCT G04HNRC G07HNCT G07HNRC G08HNCT G08HNRC G10HNCT G10HNRC G13HNCT G13HNRC G16HNCT G16HNRC G20HNCT G20HNRC G25MNCT G25MNRC G32LNCT G32LNRC G40LNCT G40LNRC G50LNCT G50LNRC G64LNCT G64LNRC 408300 408000 408301 408001 408302 408002 408303 408003 408304 408004 408305 408005 408306 408006 408322 408162 408331 408186 408332 408187 408333 408188 408334 408189 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 GG16S2FR GG16S2UR GG16S5UR GG16S5FR GG16H2FR GG16H2UR GG16H5FR GG16H5UR GG20H2FR GG20H2UR GG20H5FR GG20H5UR GG20M2FR GG20M2UR GG20M5FR GG20M5UR GG25M2FR GG25M2UR GG25M5FR GG25M5UR GG32M2FR GG32M2UR GG32M5FR GG32M5UR GG40M2FR GG40M2UR GG40M5FR GG40M5UR GG64L2UR GG64L5UR GH32M2VR GH32M5VR GH40M2VR GH40M5VR 407627 407617 407619 407629 407610 407612 407613 407615 407620 407622 407623 407625 407630 407632 407633 407635 407640 407642 407643 407645 407650 407652 407654 407656 407658 407666 407668 407670 407686 407688 408254 408255 408267 408268 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 GTG00K2-SR GTG00K4-2SR GTG00K4T6SR GTG00N5T8SR GTG00N5T9SR GTG00N6T8SR GTG00N6T9SR GTG00N7T8SR GTG00N7T9SR GTG00N8T8SR GTG00N8T9SR GTPUNI 408802 408809 408819 408849 408853 408850 408854 408851 408855 408852 408856 408860 A.26 A.26 A.26 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.12 G13HCLS G16HCLS G20H2SSL G20H5SSL G20HARC G20HCHT G20HCLS G20MCLS G20NARC G25MCLS G32MCLS G40M2SSL G40M5SSL G40MARC G40MCHT G40MCLS G40NARC G50LCLS G64L2SSL G64L5SSL G64LARC G64LCHT G64LCLS GFA4 GRHN GSFDTR1 GSFDTR2 GSDWTR GUNI 408097 408100 407606 407607 408098 408102 408103 408106 408104 408109 408117 407636 407637 408169 408131 408120 408172 408145 407679 407680 408193 408144 408148 408028 408043 408052 408030 408054 408047 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 Catalogue number combinations Sensors (CT & Rogowski) for Ground & Earth fault options Intro A B C D E F X A.39 EntelliGuard™ Notes Intro A B C D E F X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EntelliGuard™ Electronic Trip Units B.2 Electronic Trip Units layout & main menu B.3 Overload Protection LT-C and LTD B.4 Overload Protection LT-F and LTD B.5 Table indicating available Long Time settings B.6 Short-circuit Protection ST and STDB B.7 Short-circuit Protection ST and I2T slope B.8 Short-circuit Protection; Instantaneous (I) B.9 Overcurrent Protection against Short-circuit: Extended range B.10 Short-circuit Protection temporary reduced I (RELT) B.11 Setting limitations of Short-circuit devices - Short-circuit Protection: HSIOC, MCR B.12 Ground fault Protection: GF and GFD (Residual Type) B.13 Ground fault Protection: GF and I2t slope B.14 Ground Fault Protection B.15 Zone Selective Interlock, Load Shedding and Trip indication B.16 Measurement Functions and Power Supplies B.17 Protective Relaying Functions; Relay and Trip Unit Inputs Wave Form Capture option B.18 Communications Neutral protection, Reset Choice Rating Plug and Test Kit B.19 Overview of GT Electronic Trip Unit functionality Time Current Curves (cold state) B.20 LT Protection device B.21 LT Protection device B.22 LT & ST Protection device B.23 ST Protection device B.24 ST and I Protection device B.25 HSIOC & GF Protection device B.26 GF Protection device B.27 Terminology B.28 Example of Full Time Current curve The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X B.1 EntelliGuard™ Electronic Trip Units layout & Main menu Electronic Trip Units State of the Art Electronic Trip Unit All EntelliGuard™ Power Circuit Breakers are equipped with a digital electronic trip unit, available in four basic versions E, S, N and H. Each has a common design that comes with a screen providing an ammeter and allowing a simple and accurate menu driven adjustment of the breaker parameters across a broad current range. All functionality is menu driven accessed by using 4 setting and one enter key thus allowing a fast and accurate setting of the device. These have the following functionality: UP: Scroll up, Increment Value Ç DOWN: Scroll down, Decrement value È NEXT function, next page Æ PREVIOUS function, previous page Å SAVE setting into memory Å After inserting the Universal rating plug, the device can be adjusted and the installed options set. In situations where the installation is not yet connected to the power supply, the use of the separately available TESTER with Power Pack is advised (Cat No. GTUTK20). Alternatively the internal Trip Unit Battery power pack can be used. Depressing any key on the face of the trip unit powers the unit from its internal battery. Battery power is maintained for 20 seconds after the last key is pressed. All normal setup, meter, and status functions can be performed with battery power. In Power On situations the Trip Unit display is only functional when the breaker is carrying at least 20% of its nominal current value (Single phase). Intro SET UP METER A STATUS EVENTS B C SET UP D METER STATUS E EVENTS F SET UP METER X SET UP MENU To enter this option begin the process by pressing the UP or DOWN key until SETUP is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to enter the setup mode. After selecting this mode, all functions can be chosen by depressing the NEXT or PREVIOUS key. Within the setup menu all breaker protection values, trip unit parameters, relaying functions in and outputs, communication and trip unit access codes are set Each EntelliGuard™ Electronic trip units provides long-time over-current protection (LT), longtime delay (LTD) and some form of Short-circuit over-current protection (ST and/or I, H, RELT). Depending on the chosen Trip Unit Tier or Type and the selected options a, host of other protection, metering relaying functions and a wave form capture option are available. In the following pages each of these functions are described in detail. A set of tabs placed below each description indicate in which Trip Unit Tier the described function is present. METER To enter this option begin the process by pressing the UP or DOWN key until to METER is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to view various groups of measurements as Current, Voltage, real, apparent and reactive Power for the electrical system protected by the device. Both currents and voltages are computed as true rms values. All EntelliGuard™ Trip Units are equipped with an Ammeter. The full measurement package is offered in the GT-N and GT-H variants. The ammeter and other measurement options are only available when the trip unit is powered by the distribution system, the internal Trip Unit batteries or the external Test/battery pack. The full measurement package requires the use of a separately available 3 phase instrument transformer and Power Conditioner pack. STATUS To enter this option begin the process by pressing the UP or DOWN key until STATUS is selected on the screen. The Status option indicates the present status and settings of the trip unit and circuit breaker. STATUS EVENTS SET UP METER STATUS EVENT EVENTSLOG B.2 EVENTS To enter this option begin the process by pressing the UP or DOWN key until EVENTS is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to access events. Here a total of 10 events with data as event type and event magnitude are stored. The connection of a 24V DC auxiliary supply to the Trip Unit will expand this option to include a time stamp of each event. Tripping events as LT, ST, I GF, Overload Trip imminent (pre alarm) or any other, release or relay trip event are visualized with the associated levels. It is possible to clear this so called “trip register” locally. If the Trip Unit is equipped with this option, a history of up to 256 Tripping occurrences with data as event type and event magnitude are stored. EntelliGuard™ Overload Protection LT-C and LTD SET UP SET CURRENT METER 1000A STATUS Ie LONG TIME pickup 0.5 BAND C5 Ir = 500A EVENTS EntelliGuard GT Electronic Trip Unit 10000 2h - Time Current Curve LT- Protection Device C bands Overload Protection Overload (LT-C) Protection The EntelliGuard™ Electronic Trip has an extremely accurate and easy to set overload or Long Time (LT-C) Protection. It is designed to pick up overloads that exceed 112% of the set value within two hours with a tolerance of 10%(1). The available 66 different current adjustments (see page B.4) result in an extremely broad setting range of 0,2 to 1 times the chosen breaker rating (In). The LT-C type is designed to be used in association with down- and upstream circuit breakers and has a so called I2t shape producing a curve form similar to standard industrial thermal magnetic protection devices. The Time-Current protection curve depicted here is drawn in cold state. A thermal model in the device corrects for the heating of the connected lines and equipment. This device continues to track cooling even when disconnected in ‘Thermal Memory’. The reconnection of power to over-heated lines and equipment thus being prevented. Thermal Memory tracks events after power disconnection for up to 12 minutes. In order to allow an accurate adjustment to the thermal properties of the protected equipment and to finely match the curve with those of Upstream & Downstream devices 22 LTD time bands are available. The table indicates the minimum delay time and maximum total interruption times for 3 frequently used reference points on the curve of each band. The graph portrays the LT behaviour for the time-current bands C-4, C- 8, C-13 & C-22. Intro 1000 A B 100 C Tripping Time In Seconds (s) 10 D E 1 F X 0,1 1,00 10,00 x Breaker Rating In 100,00 7,2 x ] Overload Tripping times at indicated overload levels per selected LTD band, in Seconds x Ir Cmin C-2 C-3 C-4 Max. 7,8 23,4 46,7 62,3 1.5 Min. 4,0 12,0 24,0 32,0 Max. 1,3 3,86 7,73 10,3 3 Min. 0,80 2,41 4,82 6,43 Max. 0,21 0,62 1,24 1,66 7.2 Min. 0,13 0,40 0,81 1,07 Motor Protection Class to IEC 947-4 Standard on C-5 93,4 48,0 15,5 9,64 2,49 1,61 C-6 125 64,1 20,6 12,9 3,32 2,15 C-7 C-8 156 187 80,1 96,1 25,8 30,9 16,1 19,3 4,15 4,98 2,69 3,22 10b GT-E C-9 218 112 36,1 22,5 5,81 3,76 C-10 249 128 41,2 25,7 6,64 4,30 GT-S C-11 280 144 46,4 28,9 7,47 4,83 10 C-12 311 160 51,5 32,1 8,30 5,37 C-13 374 192 61,8 38,6 9,96 6,45 C-14 436 224 72,1 45,0 11,6 7,52 20 GT-N C-15 498 256 82,4 51,4 13,3 8,60 C-16 560 288 92,7 57,8 14,9 9,67 C-17 623 320 103 64,3 16,6 10,7 30 C-18 685 352 113 70,7 18,3 11,8 C-19 747 384 124 77,1 19,9 12,9 C-20 C-21 810 872 416 448 134 144 83,6 90,0 21,6 23,2 14,0 15,0 40 Cmax 934 480 155 96,4 24,9 16,1 GT-H (1) Meeting the requirements of IEC 90647-2 and IEC 90647-4 B.3 EntelliGuard™ Electronic Trip Units Overload Protection LT-F and LTD Intro A B C Overload (LT-F) Protection Optionally a second type of overload protection is available. Designed to pick up overloads that exceed 112% of the set value within two hours, with a tolerance of 10%(1), it has the same 66 different current adjustments as the standard type thus offering a extremely broad setting range of 0,2 to 1 times the chosen breaker rating. The Time-Current protection curve depicted here is drawn in cold state. A thermal model in the device corrects for the heating of the connected lines and equipment. This device continues to track cooling even when disconnected in ‘Thermal Memory’. The reconnection of power to over- heated lines and equipment thus being prevented. Thermal Memory tracks events after power disconnection for up to 12 minutes. The LT-F device is designed to be used in association with down- and upstream Fuses and produces a curve form similar to those of standard industrial fuses. A total of 22 LTD time bands are available, thus extending the total number of bands to 44. The table indicates the minimum delay time and maximum total interruption times for 3 frequently used reference points on the curve of each band. The graph portrays the LT behaviour for the time-current bands F-4, F-9, F-15 and F-22. SET UP SET CURRENT METER 1000A STATUS Ie LONG TIME pickup 0.5 BAND F2 Ir = 500A EVENTS EntelliGuard GT Electronic Trip Unit 10000 - Time Current Curve LT- Protection Device - F Bands 2h 1000 100 10 D Tripping Time In Seconds (s) E F X 1 0,1 1,00 10,00 100,00 x Breaker Rating In ] Overload Tripping times at indicated overload levels per selected LTD band. in Seconds x Ir Max. Min. Max. 3 Min. Max. 7,2 Min. 1,5 Fmin 1,44 0,64 0,09 0,04 Standard on B.4 F-2 4,19 1,87 0,26 0,12 F-3 7,62 3,39 0,48 0,21 F-4 11,9 5,30 0,74 0,33 F-5 17,2 7,67 1,08 0,48 0,03 0,01 F-6 23,9 10,7 1,50 0,67 0,05 0,02 F-7 32,3 14,4 2,01 0,90 0,06 0,03 F-8 42,8 19,0 2,67 1,19 0,08 0,04 F-9 56 25 3,49 1,55 0,11 0,05 F-10 72 32 4,51 2,01 0,14 0,06 F-11 93 41 5,80 2,57 0,18 0,08 F-12 118 53 7,39 3,29 0,22 0,10 F-13 150 67 9,39 4,18 0,28 0,13 F-14 190 85 11,9 5,29 0,36 0,16 F-15 239 107 15,0 6,68 0,45 0,20 F-16 302 135 18,9 8,41 0,57 0,25 F-17 380 169 23,8 10,6 0,72 0,32 GT-H F-18 477 213 29,9 13,3 0,90 0,40 F-19 600 267 37,5 16,7 1,13 0,50 F-20 752 335 47,0 20,9 1,42 0,63 F-21 942 419 58,9 26,2 1,78 0,79 Fmax 1153 514 72,1 32,1 2,18 1,03 EntelliGuard™ Table indicating available Long Time settings Per chosen Breaker Rating (In) 66 Current values (Ir) can be set 400 380 360 340 320 300 280 260 240 220 200 630 599 567 536 504 473 441 410 378 347 315 800 760 720 680 640 600 560 520 480 440 400 1000 950 900 850 800 750 700 650 600 550 500 1250 1188 1125 1063 1000 938 875 813 750 688 625 1600 1520 1440 1360 1280 1200 1120 1040 960 880 800 Primary Setting Ie values in Amps Secundary Setting Ir values in Amps 390 385 380 180 371 366 361 171 351 347 342 162 332 327 323 153 312 308 304 144 293 289 285 135 273 270 266 126 254 250 247 117 234 231 228 108 215 212 209 99 195 193 190 90 615 610 605 280 584 580 575 266 554 549 545 252 523 519 514 238 492 488 484 224 461 458 454 210 431 427 424 196 400 397 393 182 369 366 363 168 338 336 333 154 308 305 303 140 784 776 768 350 745 737 730 333 706 698 691 315 666 660 653 298 627 621 614 280 588 582 576 263 549 543 538 245 510 504 499 228 470 466 461 210 431 427 422 193 392 388 384 175 980 970 960 450 931 922 912 428 882 873 864 405 833 825 816 383 784 776 768 360 735 728 720 338 686 679 672 315 637 631 624 293 588 582 576 270 539 534 528 248 490 485 480 225 1225 1210 1196 560 1164 1150 1136 532 1103 1089 1076 504 1041 1029 1017 476 980 968 957 448 919 908 897 420 858 847 837 392 796 787 777 364 735 726 718 336 674 666 658 308 613 605 598 280 1568 1552 1536 720 1490 1474 1459 684 1411 1397 1382 648 1333 1319 1306 612 1254 1242 1229 576 1176 1164 1152 540 1098 1086 1075 504 1019 1009 998 468 941 931 922 432 862 854 845 396 784 776 768 360 160 152 144 136 128 120 112 104 96 88 80 250 238 225 213 200 188 175 163 150 138 125 315 299 284 268 252 236 221 205 189 173 158 400 380 360 340 320 300 280 260 240 220 200 500 475 450 425 400 375 350 325 300 275 250 630 599 567 536 504 473 441 410 378 347 315 Breaker Multip. Rating 2000 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 2500 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 3200 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 4000 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 5000 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 6400 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 2500 2375 2250 2125 2000 1875 1750 1625 1500 1375 1250 3200 3040 2880 2720 2560 2400 2240 2080 1920 1760 1600 4000 3800 3600 3400 3200 3000 2800 2600 2400 2200 2000 5000 4750 4500 4250 4000 3750 3500 3250 3000 2750 2500 6400 6080 5760 5440 5120 4800 4480 4160 3840 3520 3200 Primary Setting Ie values in Amps Secundary Setting Ir values in Amps 1960 1940 1920 900 1862 1843 1824 855 1764 1746 1728 810 1666 1649 1632 765 1568 1552 1536 720 1470 1455 1440 675 1372 1358 1344 630 1274 1261 1248 585 1176 1164 1152 540 1078 1067 1056 495 980 970 960 450 2450 2425 2400 1125 2328 2304 2280 1069 2205 2183 2160 1013 2083 2061 2040 956 1960 1940 1920 900 1838 1819 1800 844 1715 1698 1680 788 1593 1576 1560 731 1470 1455 1440 675 1348 1334 1320 619 1225 1213 1200 563 3136 3104 3072 1440 2979 2949 2918 1368 2822 2794 2765 1296 2666 2638 2611 1224 2509 2483 2458 1152 2352 2328 2304 1080 2195 2173 2150 1008 2038 2018 1997 936 1882 1862 1843 864 1725 1707 1690 792 1568 1552 1536 720 3920 3880 3840 1800 3724 3686 3648 1710 3528 3492 3456 1620 3332 3298 3264 1530 3136 3104 3072 1440 2940 2910 2880 1350 2744 2716 2688 1260 2548 2522 2496 1170 2352 2328 2304 1080 2156 2134 2112 990 1960 1940 1920 900 4900 4850 4800 2250 4655 4608 4560 2138 4410 4365 4320 2025 4165 4123 4080 1913 3920 3880 3840 1800 3675 3638 3600 1688 3430 3395 3360 1575 3185 3153 3120 1463 2940 2910 2880 1350 2695 2668 2640 1238 2450 2425 2400 1125 6272 6208 6144 2880 5958 5898 5837 2736 5645 5587 5530 2592 5331 5277 5222 2448 5018 4966 4915 2304 4704 4656 4608 2160 4390 4346 4301 2016 4077 4035 3994 1872 3763 3725 3686 1728 3450 3414 3379 1584 3136 3104 3072 1440 800 760 720 680 640 600 560 520 480 440 400 1000 950 900 850 800 750 700 650 600 550 500 1280 1216 1152 1088 1024 960 896 832 768 704 640 1600 1520 1440 1360 1280 1200 1120 1040 960 880 800 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 2560 2432 2304 2176 2048 1920 1792 1664 1536 1408 1280 Overload Protection Breaker Multip. Rating 400 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 630 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 800 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 1000 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 1250 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 1600 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 Intro A B C D E F X B.5 EntelliGuard™ Electronic Trip Units Short-circuit Protection ST and STDB Intro A Overcurrent Protection against Short-circuit: ST, STDB The EntelliGuard™ Electronic Trip Unit and breaker combination can be equipped with a number of different Short-circuit protection devices each with their own distinctive properties and field of application. The Timed Short-circuit Protection Device is designed to offer selectivity over a defined current range and offers a unique combination of multiple time bands and current settings. SET UP SET CURRENT METER 1000A STATUS Ie SHORT TIME PICKUP 3 x lr ST BAND 2 SLOPE OFF EVENTS To allow selectivity with a wide range of different downstream devices whilst not unnecessarily sacrificing clearing time, 17 different time bands are available. The device has an adjustment range of 1,5 to 12(1) (+-10%) times the chosen Long Time current value (Ir) in steps of 0,5 (pick up setting). EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve ST- Protection Device I2t OFF- STDB bands The graph indicates 6 of the available 17 time bands across the full adjustment range. The table contains the minimum delay time and the maximum total interruption times for all time band settings. 1 0,8 0,6 0,4 B 0,2 C 0,1 D Tripping Time In Seconds (s) E F X 0,01 0,001 1,00 10,00 100,00 x Breaker Rating In ] Short Time tripping times at indicated levels per selected STDB band - I2t OFF, in Milliseconds 1,5 x ±10% 12 x ±10% x Ir Tripping Non Tripping Tripping Non Tripping Standard on Min 90 30 90 30 2 100 40 100 40 3 110 50 110 50 4 120 60 120 60 5 170 110 170 110 6 190 130 190 130 GT-E (1) Is limited to lower values in certain cases, please refer to page B.11 B.6 7 240 180 240 180 GT-S 8 270 210 270 210 9 300 240 300 240 10 340 280 340 280 GT-N 11 400 340 400 340 12 450 390 450 390 13 600 540 600 540 GT-H 14 700 640 700 640 15 800 740 800 740 16 900 840 900 840 Max 1000 940 1000 940 EntelliGuard™ Short-circuit Protection ST and I2T slope EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device - STDB bands 1 0,8 0,6 0,4 0,2 Tripping Time In Seconds (s) 0,1 Ground fault Protection Timed Short-circuit (ST) Protection I2T Bands (slope)(1) The ST device can also be set to a I2T slope value. The available multiple I2t slopes are normally used to achieve selectivity with downstream fuses or to improve selectivity with downstream circuit breakers. The device has an adjustment range of 1,5 to 12 (1) (±10%) times the chosen Long Time current value (Ir) in steps of 0,5 (pick up setting) and 17 time bands. The three graphs depict the available I2t slopes (Low, Med. or High) and their intersection with a selection of the available 17 time bands across the full adjustment range. I2t ON "low" I2t -ON "low" STDB bands 0,01 SET UP SHORT TIME Intro METER PICKUP 3 x lr ST BAND 2 SLOPE OFF A STATUS 0,001 1,00 10,00 100,00 EVENTS x Breaker Rating In ] B EntelliGuard GT Electronic Trip Unit 10 EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device - Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device C I2t ON "max." I2t ON "med." I2t - ON "max." STDB Bands - STDB Bands "med." I2t -ON STDB Bands - STDB Bands D 1 0,8 1 0,8 0,6 0,6 0,4 0,4 0,2 0,2 0,1 0,1 E F Tripping Time In Seconds (s) Tripping Time In Seconds (s) X 0,01 0,001 1,00 10,00 100,00 0,01 0,001 1,00 x Breaker Rating In 10,00 ] Standard on 100,00 x Breaker Rating In GT-E GT-S ] GT-N GT-H 2 (1) When the LT Fuse band option is selected (22 F Bands) the I T slope functions of this device are disabled B.7 EntelliGuard™ Electronic Trip Units Short-circuit Protection; Instantaneous (I) Intro A Instantaneous Short-circuit (I) Protection A user settable device that allows a high speed fault interruption at a pre-determined current level. This device can be used with the short time delayed (ST) Short-circuit protection device or as replacement thereof. The device has a current adjustment of 2 to 15 (±10%) times the chosen Primary Current Value (Ie) in steps of 0,5. The device can also be switched OFF. On breakers with a rating of more than 4000A the maximum setting of 15 x is in some cases limited to a lower value due to the breaker current rating and its Short-circuit withstand value (see page B.11). The Instantaneous tripping system used in the EntelliGuard™ Electronic Trip Unit has a unique programming feature that waits for the downstream device to trip before reacting to an overcurrent fault. This providing the user with a unique combination of Speed and Selectivity. SET UP BREAKER RATING METER 1000A INST PICKUP 2 x le STATUS EVENTS 1 - Time Current Curve I - Protection Device The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11). 0,1 B C D 0,01 Tripping Time in Seconds (S) E F X 0,001 1,00 10,00 100,00 x Breaker Rating (In) Standard on B.8 GT-S GT-N GT-H EntelliGuard™ Short-circuit Protection; Instantaneous (I) SET UP BREAKER RATING METER 1000A INST PICKUP 16 x le STATUS EVENTS 1 - Time Current Curve Ext. I - Protection Device Short-circuit Protection Extended Range Instantaneous Protection Derived from, and based on the same principles as the standard Instantaneous protection but with and extended current adjustment range. This high-level instantaneous device extends the standard range from 2 - 15 to 2 - 30 (±10%) times the chosen Primary Current Value (Ie). Until 15 x Ie in steps of 0,5 and for the extended setting (above 15 x Ie) in steps of 1. The device can also be switched OFF. On breakers with a rating of more than 2000A the maximum setting of 30 x is in some cases limited to a lower value due to the breaker current rating and its Short-circuit withstand value (see page B.11). As with the standard Instantaneous tripping system the device has a unique programming feature that waits for the downstream device to trip before reacting to an overcurrent fault. This providing the user with a unique combination of Speed and Selectivity. Intro The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11). A 0,1 B C D Tripping Time in Seconds (S) 0,01 E F X 0,001 1,00 10,00 100,00 x Breaker Rating (In) Optional on GT-S GT-N GT-H B.9 EntelliGuard™ Electronic Trip Units Short-circuit Protection temporary reduced I (RELT) Intro A Temporary reduced setting of Instantaneous Short-circuit Device (RELT) When a Short-circuit event takes place, large amount of electrical energy is released that can be hazardous to users in the direct vicinity of such an occurrence. In order to limit the current levels during such events and to reduce their time span, the EntelliGuard™ G Electronic Trip Unit can be equipped with a temporary Reduced Instantaneous Device. The RELT device can be turned ON by accessing input one of the trip unit (1). When the device is switched ON Relay output one (1) changes position and reverts to it’s standard position when RELT is OFF. The RELT device can be adjusted from 1,5 to 15 (±10%) times the Chosen Primary Current Value (Ie) in steps of 0,5 (pick up setting). The device will trip the breaker within 50 Milliseconds. SET UP BREAKER RATING METER 1000A RELT PICKUP 3 x le STATUS EVENTS 1 - Time Current Curve RELT - Protection Device The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11). Information on how to set this device can be found in IEEE standard 1548. 0,1 B (1) See section on electronic inputs and Relay ouputs on page B.17 C D 0,01 Tripping Time in Seconds (S) E F X 0,001 1,00 10,00 100,00 x Breaker Rating (In) Standard on B.10 GT-N GT-H EntelliGuard™ Setting limitations of Short-circuit devices Short-circuit Protection: HSIOC, MCR These values are indicated in the adjacent table. Breaker Primary Rating setting In current Ie 5000A 5000A 6400A 6400A 2000A 2500A 3200A 4000A 5000A 6400A 2000A 2500A 3200A 4000A 5000A 6400A Breaker Icw rating 65kA 85kA 100kA Maximum ST setting (x Ir) 10x 10x 10x 10x Maximum I or Ext. I setting (x Ie)(1) 24x 30x 30x 30x 25x 30x 30x 19x 25x 30x 15x 20x 24x 15x 19x 13x 15x 50kA Breaker type is not available HSIOC Protection device To prevent very high level Short-circuit currents causing damage to their electrical installation and their components EntelliGuard™ Power Circuit Breaker are equipped with a HSIOC protection device. This high-level Short-circuit device is installed in all EntelliGuard™ Breakers and is designed to trip the breaker at the specified Icw value of the device(3). The device interrupts and thus limits the duration of these high level Short-circuits to 40 Milliseconds. The HSIOC device is normally set at a value that is slightly higher than the specified 1 second Icw of the breaker in which it is installed. This to warranty selectivity at the specified 1 second level taking system tolerances into account(2). Making Current (MCR) Protection device If a breaker is closed onto a Short-circuit current it is mandatory that the device interrupts before the electrical installation and its components incur any damage. An MCR device is present in all EntelliGuard™ Power Circuit Breakers(3) specifically designed to trip the breaker when closing onto a fault. Overview of installed HSIOC devices in Automatic types: Set value (rms) Envelope 1 Short-circuit Protection Setting Limitations of Short-circuit devices. To prevent damage to the EntelliGuard™ breaker due to currents that exceed its design parameters, the maximum setting values of the ST & I devices are in some cases limited to a lower level. GG04S to GG20S GG04N to GG20N GG04H to GG20H 50000 A 65000 A 65000 A GG25N to GG40N GH32N & GH40N GG04E to GG20E GG25H to GG40H GH32H & GH40H GH32M & GH40M 65000 A 65000 A 85000 A 85000 A 85000 A 85000 A GG32G to GG40G GG40M to GG64M GG40L to GG64L 100000 A 100000 A 100000 A B Set value (rms) C GG04S to GG20S GG04N to GG20N GG04H to GG20H 42000 A 50000 A 65000 A D GG25N to GG40N GH32N & GH40N GG04E to GG20E GG25H to GG40H GH32H & GH40H GH32M & GH40M 65000 A 65000 A 85000 A 85000 A 85000 A 85000 A GG32G to GG40G GG40M to GG64M GG40L to GG64L 100000 A 100000 A 100000 A Envelope 2 Intro A Envelope 3 Overview of installed MCR devices in Automatic types: Envelope 1 Envelope 2 Envelope 3 E F X Overview of installed MCR devices in Non Automatic types: Set value (rms) Envelope 1 GW04N to GW20N 65000 A GW04M to GW40M GZ32H & GZ40H 85000 A 85000 A GJ40L to GJ64L 100000 A Envelope 2 Envelope 3 (1) If the Short Time Device (ST) is turned OFF the highest instantaneous or extended instantaneous setting is reduced to 15 x Ie for all types ≤ 4000A and to 10 x Ie for the 5000 and 6400A types (2) If the breaker is not equipped with an Instantaneous protection device (I or Hi) or in cases where device is set to off the HSIOC device current threshold is automatically reduced by 10% (3) Only included in selected NON Automatic types B.11 EntelliGuard™ Intro A B C D E Ground Fault (GF) Protection To protect an installation or a part thereof against indirect contact, Protection Devices can be used to automatically disconnect the power supply when a fault to earth is detected. The HD384 installation standard requires that the mentioned device senses the fault and then interrupts the supply within a specified time frame. A Short-circuit device as an EntelliGuard™ Power Circuit Breaker can be used to meet this requirement. However these Short-circuit Protection devices are normally set at values that are too high to detect normally occurring faults to Earth. The optionally available Ground Fault protection feature is specifically designed to detect lower currents than a standard Short-circuit Device and operate by residually summing the current in the Phases and Neutral. When a fault to Earth creates an unbalance in the system the resulting Fault Current is detected by the device that produces an alarm signal or trips the associated Circuit breaker thus disconnecting the circuit. The EntelliGuard™ Ground fault device has an adjustment range of 0,2 to 1(1) (±15%) times the chosen breaker rating (In) and can be set in steps of 0,01 (pick up setting). To allow selectivity with other downstream Protection Devices there are 14 different time band settings available. The graph indicates a number of the available 14 time bands across the full adjustment range. The table contains the minimum delay time and the maximum total interruption times for all time band settings. The Ground fault device must monitor the current in all Phases and the Neutral. When a 3 pole device is used in a 4 wire (3phase + Neutral) system a 4th sensor must be placed in the Neutral(2). On use of a 4 pole EntelliGuard™ breaker the sensor is already present in the Neutral pole. SET UP BREAKER RATING GF SUM METER 1000A PICKUP 0,3 x CT BAND 2 Slope OFF STATUS EVENTS EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve GF- Protection Device I2t slope -OFF- GFDB Band 1 0,8 0,6 0,4 0,2 0,1 Tripping Time In Seconds (s) Electronic Trip Units Ground fault Protection: GF and GFD (Residual Type) F X 0,01 0,10 1,00 10,00 x Breaker Rating In ] Ground Fault tripping times at indicated levels per selected GFDB band -I2t slope OFF, in Milliseconds 0,2 x ±10% 0,6 x ±10% x Ir Tripping Non Tripping Tripping Non Tripping 1 110 50 110 50 2 120 60 120 60 3 140 80 140 80 4 170 110 170 110 5 190 130 190 130 6 240 180 240 180 7 270 210 270 210 8 340 280 340 280 9 400 340 400 340 (1) When an auxiliary supply is connected (24V DC) an extra setting range of 0,1 to 0,2 becomes available (2) Use a Rogowksi coil of the appropriate rating B.12 10 450 390 450 390 11 600 540 600 540 12 700 640 700 640 13 800 740 800 740 14 900 840 900 840 EntelliGuard™ Ground fault Protection: GF and I2t slope EntelliGuard GT Electronic Trip Unit - Time Current Curve - Time Current Curve Protection Device GF- GFProtection Device 10 I2t 'low' -ON- I2t -'low' -ONGFDB Bands - GFDB Bands 1 0,8 0,6 0,4 0,2 Tripping Time In Seconds (s) 0,1 0,01 0,10 1,00 10,00 x Breaker Rating In GF SUM Intro PICKUP 0,3 x CT BAND 2 Slope Med. A B ] EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10 Ground fault Protection Ground Fault Protection I2T Bands (slope) The GF device can also be set to a slope value. The available multiple I2t slopes are normally used to achieve selectivity with downstream fuses or to improve selectivity with downstream circuit breakers. The user has the possibility to choose a current adjustment of 0,2 to 1(1) times the chosen breaker rating (In) in steps of 0,01 (pick up setting) and one of 14 time bands. The three graphs depict the available I2t slopes (Set at positon Low, Med. or High) and their intersection with several of the available 14 time bands across the full adjustment range. 10 - Time CurrentCurve Curve - Time Current ProtectionDevice Device GF- GFProtection - Time Current Curve - Time Current Curve Protection Device GF- GFProtection Device 2 C I4t ‘max’ -ON- I t 'med' -ON- -ONI2t - 'med' GFDB Bands - GFDB Bands -ONI4t -‘max’ GFDB Bands - GFDB Bands 1 1 0,8 0,8 0,6 0,6 0,4 0,4 0,2 0,2 0,1 0,1 Tripping Time In Seconds (s) Tripping Time In Seconds (s) D 0,01 0,10 1,00 E F X 0,01 0,10 10,00 1,00 ] ] Optional on 10,00 x Breaker Rating In x Breaker Rating In GT-E GT-S GT-N GT-H (1) When an auxiliary supply is connected (24V DC) an extra setting range of 0,1 to 0,2 becomes available B.13 EntelliGuard™ Ground fault Protection Electronic Trip Units Ground Return Method, Source Ground Return Method Restricted Earth Fault Applications (REF) Intro A B Ground Fault Protection (EGF) ‘Source Ground Return’ method Optionally the EntelliGuard™ Electronic Trip unit can be used with an alternative groundfault protection scheme in which the Neutral to Earth Current is measured by an ‘Earthleakage Leg Sensor’ placed in the Neutral and Earth link of the system. This option requires the use of an auxiliary supply of 24VDC and the Electronic Trip Unit needs to be set to the option CT input. An Earth leg C needs to be placed in the near vicinity of the break(1) and an interposing CT needs to be mounted in breaker. When the sensor detects a fault current the EntelliGuard™ trip trips the associated Circuit breaker thus disconnecting the circuit or optionally, produces an alarm signal. The EntelliGuard™ device has an adjustment range of 0,2 to 1(2) (+-15%) times the chosen breaker rating (In) and can be set in steps of 0,01 (pick up setting). To allow selectivity with other downstream Protection Devices there are 14 different time band settings available and three I2T slope settings (Same setting data and curves apply as on the standard GF residual (sum) protection). SET UP BREAKER RATING GF CT METER 1000A PICKUP 0,3 x CT BAND 2 Slope Med. STATUS EVENTS 4 Wire system 4 Wire system polig 33poles polig 44poles = CT = CT Optional on GT-H C D E F X Dual Groundfault Protection (Residual or Sum & Source Ground Return or CT) The EntelliGuard™ Electronic Trip Unit allows the user to combine the functionality of both the GF sum and GF CT systems thus creating a sophisticated Dual Ground Fault protection system. Based on the chosen breaker configuration and the network configuration in which the device is used devices as indicated in the adjacent table are required. An interposing current transformer (CT) is required. When a dual function ground fault is ordered off works, this device is supplied as a part of the factory mounted assembly. If a GT-H type trip unit with a dual groundfault function is ordered as a separate item the device is included in the trip unit packaging. Network 3 wire (3 phase) 4 wire (3 phase + Neutral) GF SUM PICKUP 0,3 x CT BAND 2 Slope OFF PICKUP 0,3 x CT BAND 2 Slope Med. EntelliGuard™ nr. of Poles GF Residual (SUM) 3 3 4th Rg 4 Optional on (1) Limited to 10 meters (2) When an auxiliary supply is connected (24V DC) an extra setting range of 0,1 to 0,2 becomes available B.14 GF CT GF Source Return (CT) GF sum PLUS GF CT 4th CT Int. CT 4th CT Int. CT 4th CT Int. CT 4th CT Int. CT 4th Rg 4th CT Int. CT 4th CT Int. CT GT-H EntelliGuard™ Zone Selective Interlock, Load Shedding and Trip Indication Zone Selective Interlock Zone Selective Interlock Load Shedding Function Load Shedding Function Trip(Event Reason Indicators (Event Logging) & Trip Trip Reason Indicators Logging) & Trip Operation counter (Data acquisition package) Operation counter (Data acquisition package) METER STATUS ZONE SEL/ INT. TLK EVENTS OFF ST ZSI PICKUP 3 x lr ST BAND 2 Slope OFF Zone selective Interlock (ZSI) This optional device has been specifically designed to combine Speed and Selectivity. It requires one or two simple 2 core wire to connect the ZSI in and output between two or more Electronic Trip Units(1). If a breaker detects a fault it will send a signal to the upstream breaker to move its present time setting to another predefined higher level. If the Short-circuit protection device has NO time setting GF ZSI band (Instantaneous), it simply gets a signal to wait another PICKUP 0,3 5 half cycles before tripping. x CT The breaker that originally BAND detects the faults only trips 2 Slope after transmitting the indicated Med. signals. Optional on METER STATUS Alarm ON EVENTS PICKUP 0,55 x ln When a ZSI input is received the breaker changes its time band from the standard device setting to the ZSI setting. Both of these settings are user definable and can be set independently. ZSI input sent ZSI input sent Fault occurs GT-N Load shedding alarm output The load shedding device has been designed to allow the user to switch off NON priority loads before the LT functions trips the breaker due to an overload. SET UP Time delayed Short-circuit Protection (ST..STDB) Standard and Source Return Ground Fault protection (GF, GFDB) Instantaneous (Ii and Ihi) It can also be used to verify the current consumption in the circuit which the EntelliGuard™ breaker protects. This to verify that the current running in the circuit does not exceed a certain pre-determined value. METER STATUS EVENTS SET UP METER STATUS Intro GT-H When the highest measured phase current exceeds the ‘ON’ value set for longer than 60 seconds an output is provided to indicate that ‘load shedding’ may prevent an overload tripping event. When the highest measured phase current drops below the ‘OFF’ setting for longer than 60 seconds, the output is stopped(2). This function is part of the data acquisition and relaying package available on the GT-H trip unit type. The device monitors the current in the circuit and provides an alarm signal if the load in one phase of the protected circuit exceeds a pre-defined value. The associated channel can be set ON or OFF and be adjusted in current values from 0.5 to 1 x the breaker rating In) in steps of 0.05. A B C D E Optional on SET UP Ground fault Protection SET UP The EntelliGuard™ Electronic Trip Unit uniquely offers this function on the following protection devices: GT-H Trip Reason Indicators (event logging) Trip Operations counter The Electronic Trip Unit keeps track of data indicating why the associated breaker has tripped and on how may occurrences have taken place. Accessible under the ‘EVENTS’ menu the Trip Reason Indicator keeps track of a maximum of 10 events that have caused the EntelliGuard™ breaker to trip. The device stores the voltage, the phase’s involved, the current value, the reason of the trip and the trip number (see counter). When an auxiliary voltage is connected, the time and date of the event are also stored. The Trip Reason Indicator registers events for the following devices. Overcurrent (LT, ST, I GF) Relaying Functions (see page B.13) Shunt or Undervoltage Release (If the associated contacts are connected via the trip unit) Accessible under the ‘STATUS’ menu the Trip Operations Counter registers a maximum of 255 overcurrent faults with their reason (LT, ST, I or GFEF). The data can be viewed and reset through the STATUS menu Pickup Status option. F X EVENTS Optional on GT-E GT-S GT-N GT-H (1) See schematics on page E.4 (2) See section on Relay Outputs on page B.17 B.15 EntelliGuard™ Measurement Functions and Power Supplies Ammeter An Ammeter is supplied with each EntelliGuard™ Electronic Trip Unit. The current in each of the three phases and the Neutral can be viewed. SETUP Electronic Trip Units METER METER STATUS Voltage EVENTS L1-N L1-N L1-N PHA/L1 700kW A Current APPR POWER PHB/L2 A PHA/L1 300A A PHA/L1 350A PHC/L3750kVA PHB/L2 320A PHB/L2 300A 480kVA PHC/L3 PHC/L3 320A 220kVA Standard on SETUP Intro METER METER STATUS A EVENTS Current GT-E Full Measurement Package GT-N & GT-H type Electronic Trip Units have an advanced measurement facility that provides the user with a comprehensive overview of all relevant electrical parameters and their values. The adjacent table indicates the available parameters, the units used and their accuracy. The device also calculates the sum of the used power in kWh, KVAh and KVArh as a total for all 3 phases. These values are kept and re-calculated every second. The Electronic Trip Unit has an option to allow these summations to be reset. C D Based on the same one second calculation method, a Power demand value is determined for Real (KW), Apparent (KVA) and Reactive (KVAR) power. If the Power supply has a neutral the values are calculated per phase and as a total of all three phases. E Units Resolution A 0000 GT-N Accuracy at 100% of breaker rating 2% GT-H A Peak Power Demand calculation is available for Real Power(KW) only. Here the data is stored and when necessary renewed at a user definable pre-set time interval. When the new Peak Demand value exceeds the previous stored value the new value replaces the old in Memory. The Electronic Trip Unit has an option to reset this value. Parameter Current Measured Units Resolution L1, L2, L3, N A Voltage L1, L2, L3 V Power Factor L1, L2, L3 % Frequency L1, L2, L3, N Hz Apparent Power L1, L2, L3 kVA Real Power L1, L2, L3 kW Reactive Power L1, L2, L3 KVAr Average Power demand Energy Peak Power Demand L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3 GT-N Power Conditioners and Auxiliary Power Supply To use the above mentioned comprehensive measurement facilities, it is necessary to track the 3phase and Neutral network voltages and to input these values into the Electronic Trip Unit. For this purpose the EntelliGuard™ line includes a number of ’Power Conditioners’ that transform and condition a standard network power supply to a signal that the trip unit can safely use and read. When optioning the measurement facility for the 1st time, the Electronic Trip Unit will require the user to set the primary voltage values. Accessory for L1, L2, L3, N GT-S Standard on X B.16 Parameter Measured When the option for display (Meter) is opened, a calculation is initiated that calculates each value based on a one second time frame. B F REAL POWER The device has an accuracy of 2% when viewed at the nominal current of the breaker and an accuracy of 5% when viewed when the breaker is running at 50 - 85% of its full load. kVA kW KVAr KWh KW 0000 0000 00 00 000,000 000,000 000,000 000,000 000,000 000,000 000,000 000,000 Accuracy at 100% of breaker rating 2% 2% 4% 1 cycle 4% 4% 4% 4% 4% 4% 4% 4% GT-H A number of advanced Trip Unit options require an auxiliary supply of 24V DC. A unit that transforms and conditions a standard network power supply to 24V DC is available for this purpose. The auxiliary supply also improves the speed of the trip unit setup function at low circuit loads (<20%) and when no standard power supply is present. A separately available Test Box Kit can also be used as a temporary power supply. This device has a battery pack and includes a 24 V DC auxiliary power supply. GT-S GT-N GT-H EntelliGuard™ Protective Relaying Functions; Relay and Trip Unit Inputs Wave Form Capture Option SET UP METER STATUS Protective Relay Adjustability 110% -115% of line voltage 1 to 15 seconds 30% - 85% of line voltage 1 to 15 seconds 10% -50% difference between highest & lowest phase when compared to average Voltage Unbal. Delay 1 to 15 seconds Power Direc. Reversal Line- to-Load OR Load to Line Power Reversal setting From 10 to 990kW 10% -50% difference between highest & Current Unbalance lowest phase when compared to average Current Unbal. Delay 1 to 15 seconds Overvoltage Overvoltage Delay Undervoltage Undervoltage Delay Voltage Unbalance Standard on SET UP METER STATUS EVENTS Relay Outputs There are two programmable relay outputs available rated at 1A 30V AC or DC. The first is dedicated to the Reduced Instantaneous Device whilst the second can be assigned to single functions, a group of functions or to the protective relays functions mentioned above. Accessible under the ‘SETUP’ the output is wired out through the secondary terminals of the breaker as indicated on page E.7. Standard on METER STATUS EVENTS METER STATUS EVENTS Standard on 1sec 2% ON or OFF ± 0,1 s 2% ON or OFF ± 0,1 s 2% ON or OFF ± 0,1 s 10kW 1% 2% 2% 1sec ± 0,1 s ON or OFF ON or OFF Relay Output reset (Group 2, 3, & 8) If a 24 V DC power supply is present and the event associated with the relay closure causes the breaker to trip the contacts will not change position. A breaker re-set & re-closure will reset the contacts to their original open position. Function GF Alarm(1) Over-current Trips (LT, ST, INST, GF) Protective Relays Current Alarm 1 Current Alarm 2 Health status GF Alarm and GF trip indication A Assigned to group 1 Assigned to group 2 Assigned to group 3 Assigned to group 4 Assigned to group 5 Assigned to group 6 Assigned to group 8 B GT-H Electronic Trip unit INPUTS There is a total of 2 programmable inputs available. The first is dedicated to switch the Reduced Instantaneous ON. The second can be used to trip the breaker. The inputs are suitable for voltages up to 24V AC or 30V DC. Accessible under the ‘SETUP’ the outputs are wired out through the secondary terminals of the breaker as indicated on page E.7. C D E F GT-N Wave Form Capture option When a fault has taken place, it can be of importance to visualize the event. The Wave form Capture option included in the GT-H type Electronic Trip Unit can track and visualize any fault event. The device tracks 8 cycles, 4 before and 4 after the event with resolution of 48 samples per cycle at 50Hz and stores the results in memory. It registers Intro Group (1) Only works when a trip unit has the Ground fault alarm installed (GFA). GT-N Standard on SET UP 1% 1sec 1% 1sec 1% GT-H Relay Output Reset (Group 1, 4, 5 & 6) If the reason of the contact closure is removed the contact will re-open. This typically occurring when a health status warning is produced or when a current alarm drops below it’s threshold. If the breaker trips whilst the relay contacts are activated the contacts will be reset and revert to their original open position. SET UP Trips Breaker Steps Accur. Advanced Features EVENTS Protective Relaying Functions The GT-H Electronic trip unit has five protective relay functions. These can be switched ON or OFF and when active produce an alarm signal that is added to the Event Log and transmitted through the communication bus. Each relay function can be configured to trip the breaker or/ and to send an alarm signal via a Relay Output. GT-H X events in all three phases and the Neutral. After the event, the waveform event is stored and can be accessed by using the waveform client module of the Enervitsa software. When the upload into this software is complete, the Trip Unit will reset this function and be available to register the next event. GT-H B.17 EntelliGuard™ Communications Neutral protection, Reset Choice, Rating Plug and Test Kit SET UP METER Electronic Trip Units STATUS EVENTS Communications A number of the GT Electronic trip unit types can be optioned to allow the Breaker & Trip Unit combination to communicate data bi-directionally through Modbus or Profibus. The communication option needs a 24 V auxiliary voltage input capable of supplying 90mA for the Modbus option and 240mA for the Profibus option. Modbus and Profibus can be directly connected to the Trip Unit without the use of any interfaces. In combinatioin with communications the use of the specifically designed Command Closing Coil and auxiliary contacts with signal ratings are required. Trip unit parameters as over current settings, protective relay functions, alarm settings etc. can be accessed through communications. A locking Optional on Intro SET UP A METER STATUS B EVENTS Standard on C Neutral Protection When inserted into a 4 pole breaker the EntelliGuard™ Electronic Trip Unit senses that the breaker in which the device is installed has a Neutral Pole. Via the set Up menu, a Neutral Setting option then becomes available in which the LT, ST and I protection device can be jointly set to GT-E GT-S Reset Choice Function When a fault has occurred the Trip Unit trips the associated breaker. It is then deemed normal installation practise to verify the reason of the fault before reconnecting power by resetting and switching the breaker on. The advanced options included in the EntelliGuard™ Trip Unit provide the user with the fault reason, magnitude and location, thus allowing the user to easily establish the D E F GT-S Standard on GT-E GT-S Full Range Rating Plug Each EntelliGuard™ Electronic Trip Unit must be equipped with a separately available Rating Plug to allow it to function correctly. The Full Range Rating Plug is plugged in to a jack on the trip Unit Front Face. When this device is not installed, the X Accessory for GT-E GT-S Test Kit To verify that the Electronic Trip Unit is interfacing correctly with the Breaker and to establish if the circuitry in the Trip Unit is functioning correctly, a test kit is available. The device has a battery pack Accessory for B.18 GT-E GT-S password is provided that prevents unauthorized changes through communication or the keypad. The Modbus variant is fully compliant with the Modbus Protocol and uses 2 a wire 485 connection. The device is configured to stay on one fixed baud rate, or to cycle through the baud rates until communication is established. The link host can operate at baud rates between 300 and 19,200. The Profibus protocol is integrated in specific models of the GT-H Trip Unit and uses a four wire RS 485 connection. Profibus DP is supported in A-Cyclic and Cyclic mode. For the cyclic mode the associated gsd file is available on request. A communication register can be supplied for both versions. GT-N GT-H one of the following values: 0%, 50%, 63% or 100%. x the values set for the phase protection device. GT-N GT-H required corrective actions. To follow this procedure Trip Unit reset function should be set to MANUAL. However, in some cases it is required that the breaker resets itself automatically. If this functionality is required, the reset function should be set to AUTOMATIC. A selector switch on the Trip Unit front face allows the user this choice. GT-N GT-H Trip Unit will revert to its minimum setting, which has as value of 16-18% of the breaker rating In. GT-N GT-H and a 24V auxiliary supply to allow its use in a secondary function as power supply of the Trip unit when no network power supply is available. The device can be plugged into a jack on the trip Unit Front face. GT-N GT-H EntelliGuard™ Standard Extended range Reduced Instantaneous Short-circuit Current Protection Ground or Earth Fault Protection Measurement package Data Acquisition & Protective Diagnostics Relaying Other LCD Screen allowing access to 4 distinct Menu’s Touch pad adjustments Multilingual Adjustable Manual or Automatic RESET option 6 primary current settings with FULL RANGE Rating Plug 1; 0,975; 0,9625; 0,95; 0,45 & 0,4 x Breaker rating In 11 secondary current settings Ir 1; 0,95; 0,9; 0,85; 0,8; 0,75; 0,7; 0,65; 0,6; 0,55; 0,5 x Primary setting Ie Resulting setting Range 0,2 to 1 with 66 set points 22 Thermal Protection (C type) time bands available Ranging from class 0,5 to 40 (bands at 7,2 x Ir) 22 F type (fuse) time bands available Neutral Protection 0-50%-63%-100% Cooling function and Thermal memory Setting RANGE from 1,5 to 12 x Ir (LT setting) Steps of 0,5 (A total of 22 settings) Possibility to Switch OFF 17 Time delay settings (STDB) ranging from 30 to 940 Milliseconds delay setting result in a 90 to 1000 Milliseconds Clearing time Clearance times to IEC 40979-1 and IEC 60364 3 I²t Protection time bands available Ii Setting RANGE from 2 to 15 x Ie (Primary Setting) Steps of 0,5 (A total of 28 settings) Possibility to Switch OFF Selective Execution Fixed Instantaneous or HSIOC protection Ihi Setting RANGE from 2 to 30 x Ie (Primary Setting) 2-15 Steps of 0,5; 15-30x steps of 1 (A total of 43 settings) Possibility to Switch OFF Selective Execution Fixed Instantaneous or HSIOC protection Ii Setting RANGE from 1,5 to 15 x Ie (Primary Setting) Steps of 0,5 (A total of 29 settings) Possibility to Switch OFF Remote and Local ON and OFF with position indication signal Setting RANGE from 0,1 to 1 x In (Breaker Rating)(1) Steps of 0,01 (A total of 92 settings) Possibility to Switch OFF 14 Time delay settings (GFDB) ranging from 50 to 840 Milliseconds delay setting resulting in a 110 to 900 Milliseconds Clearing time Clearance times to IEC 40979-1 and IEC 60364 3 I²t Protection time bands available Residual Principle Source Ground Return Principle UEF, REF and SEF applications possible Combinations of UEF, REF and SEF applications possible Current (L1, L2, L3, N) Voltage (L1, L2, L3) Energy (kWh) Total Real Real Power (L1, L2, L3, total) Apparent Power (L1, L2, L3, total) Reactive Power (L1, L2, L3, Total) Total Power (L1, L2, L3, total) Power (kW) Peak (total) Demand Power (kW) (total) Frequency (L1, L2, L3) Voltage Unbalance Undervoltage Overvoltage Current Unbalance Power Reversal Trip Target (trip reason indication) Trip Info (Magnitude / Phase) Waveform capture Trip Counter Event Logger (trip events) Relay based on current level (load shedding) Good & Bad Health Indicator Watchdog Zone Selective Interlock on ST, GF and I Shunt trip status input (2 inputs) UVR trip status input (2 inputs) General relay outputs (2) and electronic inputs (2) Communication 2 way Modbus Profibus 24V DC Auxiliary Power supply Text kit with Power support function GT-E X X X X GT-S X X X X GT-N X X X X GT-H X X X X Remarks ----- X X X X -- X X X X -- X X X X -- X X X X -- X X X X - X X X X - X X X X - X X X X X X ------- X X X X -- X X X X O O - X X X X X X X O O O O X O O - X X X X X X X O O O O X X X X X O O - X X X X X X X O O O O X X X X X O O O -------------------- O O O O -- O O O X X X X X O O O O O X X X X X O O O O O O O X X X X X X X X X X X X X X O X O O O O O O O O O O X X X X X X X X X X X X X X X X X X X X X X X O O O X X O O O O ---N N N -C C C C C C C C -N N N N N --N ---------N N N --- Function Overview Short Time Long Time or Overload Setting Short-circuit CurCurrent Protection Interface rent Protection Overview of GT Electronic Trip Unit Functionality Intro A B C D E F X Key X - Present; O = Optional, - = Not Possible Remarks N indicates that a 24V auxiliary power supply is required, a C indicates the need of a Power Conditioner (1) Without a 24V auxiliary power supply, the lowest setting is 0,2 B.19 EntelliGuard™ Time Current Curves (cold state) LT Protection Device EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit Electronic Trip Units 10000 2h B 1000 100 100 1 0,1 1,00 10,00 I protection set to 15 x Ie(1) 1 0,1 1,00 100,00 7,2 x LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In D 10,00 x Breaker Rating In EntelliGuard GT Electronic Trip Unit 10000 2h - Time Current Curve LT- Protection Device - Band C-02 - Band C-07 - Band C-12 - Band C-17 ST protection - OFF 10 I protection set to 15 x Ie(1) x Breaker Rating In C LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In ST protection - OFF Tripping Time In Seconds (s) A 10000 2h - Time Current Curve LT- Protection Device - Band C-06 - Band C-11 - Band C-16 - Band C-22 1000 10 Tripping Time In Seconds (s) Intro LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In 100,00 7,2 x EntelliGuard GT Electronic Trip Unit 10000 2h - Time Current Curve LT- Protection Device - Band C-03 - Band C-08 - Band C-13 - Band C-19 1000 1000 100 100 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In - Time Current Curve LT- Protection Device - Band C-04 - Band C-09 - Band C-14 - Band C-20 E F X Tripping Time In Seconds (s) Tripping Time In Seconds (s) 10 I protection set to 15 x Ie(1) 1 0,1 1,00 x Breaker Rating In B.20 ST protection - OFF ST protection - OFF 10 10,00 7,2 x 100,00 I protection set to 15 x Ie(1) 1 0,1 1,00 x Breaker Rating In 10,00 7,2 x 100,00 EntelliGuard™ Time Current Curves (cold state) LT Protection Device EntelliGuard GT Electronic Trip Unit 10000 2h LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In EntelliGuard GT Electronic Trip Unit 10000 2h 1000 1000 100 100 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In ST protection - OFF ST protection - OFF I protection set to 15 x Ie(1) 10 1 0,1 1,00 10,00 x Breaker Rating In I protection set to 15 x Ie(1) Intro Tripping Time In Seconds (s) Tripping Time In Seconds (s) 10 - Time Current Curve LT- Protection Device - Band C-01 - Band C-18 1 A 0,1 100,00 1,00 10,00 x Breaker Rating In 7,2 x 100,00 C 10000 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In 2h 1000 - Time Current Curve LT- Protection Device - Band F-01 - Band F-05 - Band F-09 - Band F-13 - Band F-17 - Band F-21 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In 2h B 7,2 x EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10000 Time Current Curves - Time Current Curve LT- Protection Device - Band C-05 - Band C-10 - Band C-15 - Band C-21 1000 - Time Current Curve LT- Protection Device - Band F-02 - Band F-06 - Band F-10 - Band F-14 - Band F-18 - Band F-22 D E F 100 100 X 10 1 ST protection - OFF I protection set to 15 x Ie(1) 0,1 1,00 x Breaker Rating In 10,00 100,00 Tripping Time In Seconds (s) Tripping Time In Seconds (s) 10 1 ST protection - OFF I protection set to 15 x Ie(1) 0,1 1,00 10,00 100,00 x Breaker Rating In B.21 EntelliGuard™ Time Current Curves (cold state) LT & ST Protection Device EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10000 10000 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In A B Tripping Time In Seconds (s) Intro 1000 LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In 2h 1000 100 100 10 10 1 ST protection - OFF I protection set to 15 x Ie(1) 0,1 1,00 10,00 Tripping Time In Seconds (s) Electronic Trip Units 2h - Time Current Curve LT- Protection Device - Band F-03 - Band F-07 - Band F-12 - Band F-15 - Band F-19 100,00 1 ST protection - OFF I protection set to 15 x Ie(1) 0,1 1,00 x Breaker Rating In C - Time Current Curve LT- Protection Device - Band F-04 - Band F-08 - Band F-13 - Band F-16 - Band F-20 10,00 100,00 x Breaker Rating In EntelliGuard GT Electronic Trip Unit 10 EntelliGuard GT Electronic Trip Unit - Time Current Curve ST- Protection Device 10 - Time Current Curve ST- Protection Device 2 D LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 E 1 0,8 17 15 0,6 13 0,4 F 17 15 13 11 LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 1 0,8 0,6 0,4 9 7 7 5 16 16 14 14 0,2 12 I2t -OFFBand STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16 10 8 8 6 6 3 1 - 12 10 5 0,1 X I t -OFFBand STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17 11 9 0,2 - 4 2 0,1 4 3 2 0,01 I protection set to 15 x Ie(1) 0,001 1,00 x Breaker Rating In B.22 Green line = Full Clearing time Red Line = Non Tripping time 10,00 100,00 Green line = Full Clearing time Red Line = Non Tripping time Tripping Time In Seconds (s) Tripping Time In Seconds (s) 1 0,01 I protection set to 15 x Ie(1) 0,001 1,00 x Breaker Rating In 10,00 100,00 EntelliGuard™ Time Current Curves (cold state) ST Protection Device EntelliGuard GT Electronic Trip Unit 10 EntelliGuard GT Electronic Trip Unit - Time Current Curve ST- Protection Device 17 15 17 15 1 0,8 13 0,6 13 0,4 11 11 LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 1 0,8 16 16 14 14 0,6 0,4 9 7 9 5 6 0,2 6 3 1 0,1 I2t ON "low" Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16 10 8 10 5 - 12 12 8 7 0,2 I2t ON "low" Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17 4 2 0,1 4 3 2 Green line = Full Clearing time Red Line = Non Tripping time 0,01 I protection set to 15 x Ie(1) 0,001 1,00 10,00 Green line = Full Clearing time Red Line = Non Tripping time Tripping Time In Seconds (s) Tripping Time In Seconds (s) 1 100,00 Intro 0,01 I protection set to 15 x Ie(1) A 0,001 1,00 x Breaker Rating In EntelliGuard GT Electronic Trip Unit 17 15 17 15 13 13 0,4 11 - - Time Current Curve ST- Protection Device 10 LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 I2t ON "med." Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17 1 0,8 16 16 14 14 0,6 11 0,4 9 7 9 5 0,2 5 3 1 0,1 E F 6 4 2 X 2 1 Green line = Full Clearing time Red Line = Non Tripping time 0,01 I protection set to 15 x Ie(1) 0,001 10,00 100,00 Green line = Full Clearing time Red Line = Non Tripping time Tripping Time In Seconds (s) Tripping Time In Seconds (s) D 4 3 x Breaker Rating In I2t ON "med." Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16 8 6 0,1 - C 10 10 7 1,00 B 12 12 8 0,2 100,00 EntelliGuard GT Electronic Trip Unit - Time Current Curve ST- Protection Device LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 0,6 10,00 x Breaker Rating In 10 1 0,8 Time Current Curves LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 - - Time Current Curve ST- Protection Device 10 0,01 I protection set to 15 x Ie(1) 0,001 1,00 10,00 100,00 x Breaker Rating In B.23 EntelliGuard™ Time Current Curves (cold state) ST and I Protection Device EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10 Electronic Trip Units B 0,6 13 0,4 11 11 ST set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 I2t ON "max." Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17 1 0,8 0,6 0,4 9 7 14 14 10 8 5 3 1 3 6 0,2 5 6 1 4 2 4 2 0,1 0,1 Green line = Full Clearing time Red Line = Non Tripping time 0,01 I protection set to 15 x Ie(1) 0,001 1,00 10,00 Green line = Full Clearing time Red Line = Non Tripping time 0,01 I protection set to 15 x Ie(1) 0,001 1,00 100,00 10,00 100,00 x Breaker Rating In x Breaker Rating In C I2t ON "max." Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16 12 12 8 7 0,2 - 16 16 10 Tripping Time In Seconds (s) A 13 9 Tripping Time In Seconds (s) Intro 17 15 17 15 1 0,8 - - Time Current Curve ST- Protection Device 10 - Time Current Curve ST- Protection Device ST set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5 1 LT set Breaker Rating In HI Setting Range 2 to 15 x Ie in steps of 0,5 1 - Time Current Curve I - Protection Device RELT - Protection Device LT set Breaker Rating In HI Setting Range 2 to 30 x Ie in steps of 0,5 i f D - Time Current Curve Ext.I - protection device RELT - Protection Device E HSIOC device 0,1 HSIOC device 0,1 F Green line = Full Clearing time Red Line = Non Tripping time X Green line = Full Clearing time Red Line = Non Tripping time 0,01 LT set Breaker Rating In RELT Setting Range 1,5 to 15 x Ie in steps of 0,5 i f 0,001 1,00 x Breaker Rating (In) B.24 Tripping Time in Seconds (S) Tripping Time in Seconds (S) 0,01 10,00 100,00 LT protection set Breaker Rating In RELT Setting Range 1,5 to 15 x Ie in steps of 0,5 0,001 1,00 x Breaker Rating (In) 10,00 100,00 EntelliGuard™ Time Current Curves (cold state) HSIOC & GF Protection Device 1 1 - Time Current Curve HSIOC - Protection Device I - Present & ON I Setting On set at 15kA ST Set at 12,5kA STDB 1 - Time Current Curve HSIOC - Protection Device I - NOT PRESENT OR OFF 65kA 0,1 0,1 50kA Green line = Full Clearing time Red Line = Non Tripping time Green line = Full Clearing time Red Line = Non Tripping time 0,01 Tripping Time in Seconds (S) Tripping Time in Seconds (S) 0,01 50kA 65kA 85kA 100kA 0,001 1000 10000 100000 Intro A 0,001 1000 1000000 10000 EntelliGuard GT Electronic Trip Unit - LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 10 - Time Current Curve GF- Protection Device I2t -OFFBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 1 0,6 11 13 11 E F 10 10 0,4 8 8 6 X 5 6 5 4 0,2 3 4 3 2 1 0,1 1 Green line = Full Clearing time Red Line = Non Tripping time 0,01 0,10 x Breaker Rating In 1,00 10,00 Tripping Time In Seconds (s) 0,1 C D 12 12 7 7 I2t -OFFBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB 14 0,6 9 0,2 B 14 14 0,8 9 0,4 - LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 1 13 1000000 EntelliGuard GT Electronic Trip Unit - Time Current Curve GF- Protection Device 10 0,8 100000 Amps Amps Tripping Time In Seconds (s) Time Current Curves 100kA 85kA Green line = Full Clearing time Red Line = Non Tripping time 2 0,01 0,10 1,00 10,00 x Breaker Rating In B.25 EntelliGuard™ Time Current Curves (cold state) GF Protection Device EntelliGuard GT Electronic Trip Unit 10 LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 - Electronic Trip Units EntelliGuard GT Electronic Trip Unit - Time Current Curve GF- Protection Device 10 I2t 'low' -ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 - 1 0,8 13 0,6 11 0,4 9 1 13 11 9 8 8 6 5 6 0,2 5 4 0,2 3 4 0,1 Green line = Full Clearing time Red Line = Non Tripping time 1 0,01 0,10 1,00 10,00 Green line = Full Clearing time Red Line = Non Tripping time 2 0,01 0,10 x Breaker Rating In C 1,00 EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve GF- Protection Device LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 - D E 13 0,6 11 I2t 'med' -ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 1 13 9 10 10 0,4 9 12 12 0,6 8 7 X 8 7 6 5 6 0,2 5 4 0,2 3 4 3 Green line = Full Clearing time Red Line = Non Tripping time 1 0,01 1,00 10,00 Tripping Time In Seconds (s) Tripping Time In Seconds (s) 0,1 x Breaker Rating In B.26 2 1 0,1 0,10 I2t ''med' -ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB 14 14 14 0,8 11 0,4 - Time Current Curve GF- Protection Device LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 1 0,8 10,00 x Breaker Rating In 10 F 2 1 Tripping Time In Seconds (s) Tripping Time In Seconds (s) B 10 10 0,4 7 7 3 A 12 12 0,6 I2t 'low' -ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB 14 14 14 0,8 0,1 Intro - Time Current Curve GF- Protection Device LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 Green line = Full Clearing time Red Line = Non Tripping time 2 0,01 0,10 x Breaker Rating In 1,00 10,00 EntelliGuard™ Terminology EntelliGuard GT Electronic Trip Unit EntelliGuard GT Electronic Trip Unit 10 - Time Current Curve GF- Protection Device LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 i f LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 10 I2t “max.”-ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13 - 1 1 0,8 13 0,6 11 13 9 8 7 7 10 10 0,4 9 12 12 0,6 8 6 5 6 0,2 5 4 0,2 3 4 3 0,1 Green line = Full Clearing time Red Line = Non Tripping time 1 0,01 1,00 10,00 In Ie Iu LT ST I GF EF Ir Ist Ii Ig LTDB STDB I2t x LT x Ie x In x CT RELT MCR HSIOC Green line = Full Clearing time Red Line = Non Tripping time 2 Intro A 0,01 0,10 1,00 10,00 B x Breaker Rating In x Breaker Rating In Denonimation Tripping Time In Seconds (s) Tripping Time In Seconds (s) 2 1 0,1 0,10 I2t “max.”-ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB 14 14 14 0,8 11 0,4 - Time Current Curve GF- Protection Device Time Current Curves and Terminology Time Current Curves (cold state) Description Current rating of Breaker Primary Current setting Maximum Breaker User current (see section D) Long Time or Overload protection Short Time or Timed Short-circuit Current setting Standard or Extended Instantaneous setting Groundfault Earthfault LT or overload Current setting ST or Timed Short-circuit Current setting Instantaneous Short-circuit Current setting Ground, or Earthfault Current setting LT or overload time delay band (C = breaker type, F = fuse type) ST or Short-circuit time delay band 'Slope' setting on ST or GF device Multiple of LT or overload Current setting Multiple of ST or Timed Short-circuit Current setting Multiple of Breaker Current rating Multiple of installed sensor rating (In IEC EntelliGuard™ types =In) Reduced Instantaneous Making Current Release Hi set Instantaneous protection C D E F X B.27 EntelliGuard™ Time Current Curves (cold state) Electronic Trip Units Example of Full Time Current Curve Time Current Curve The EntelliGuard™ Electronic trip unit has many sophisticated setting features and an extremely broad setting range. On request we can provide complete Time Current Curves covering all installed protection devices. The curves can be produced for any current setting within the range of the installed protection devices, for one or for a combination of two breakers. Please contact your local GE Sales Office for more information. EntelliGuard GT Electronic Trip Unit 10000 2h Time Current Curve Breaker In =2500A LT- Protection Device Set at Ie = 2400A Ir at 0.9 =2160A Band C-10 ST- Protection Device Set at 6 x Ir of 2160A (Ist =12960A) Band STDB 10 1000 Intro LT Band A I2t ON & Max. I- Protection Device Set at 12 x Ie of 2400A Ii = 28800A GF- Protection Device Set at 0.6 x Ie of 2500A (Ig = 1500A ) Band GFDB 6 100 B 10 C GF Band I2t ON & M d D 1 ST Band E F Tripping Time In Seconds (s) X I Band 0,1 0,01 HSIOC Band 0,001 Green & Light Blue Linel = Full Clearing time Red Line & Dark Blue Line = Non Tripping time 1000 x Current in Amps 10000 100000 7,2 x ] B.28 EntelliGuard™ Breaker Accessories C.2 Breaker Use & Operation C.3 Electrical Operation of Breaker (Motor Operator) C.4 Shunt & Undervoltage Releases; Time Delay Module for Undervoltage Release C.5 Interlock Devices, Indication Contacts and Number of devices C.6 Auxiliary Contacts C.7 Bell Alarm, Cassette position, Spring charged and Ready to Close indication contacts C.8 Mechanical Interlocking of Multiple Breakers C.9 Locking previsions for Breaker and Cassette Door-Interlock systems; Mis insertion device C.10 Installation Accessories C.11 Earthing device (maintenance accessory) Spare Parts The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X C.1 EntelliGuard™ Breaker Use & Operation Breaker Accessories A Power Circuit Breaker Intro A EntelliGuard™ is operated by a stored ➓ energy mechanism that can be charged either ➒ manually or electrically. To charge manually ➏ a handle 1 is used to ➍ ➎ ➊ ‘load’ the springs in the ➐ mechanism, 10 pumping ➌ movements being ➋ required. During charging ➑ a spring status indicator 2 clearly indicates if the breaker is CHARGED (Red), Indicated Breaker is of a Fixed CHARGING (Yellow), or Pattern and equipped with Trip Unit DIS-CHARGED (Green). After charging is complete, the ready to close indicator 3 indicates that the device can be turned ON and OFF(1) by the ON/ OFF buttons ( 4 & 5 ) on the breaker front facia. A padlocking mechanism 6 is present for up to three locks that can prevent un-authorized pushbutton operation. An electrical charging mechanism negates the need for loading the springs manually and allows remotely located pushbuttons to be used to switch ON & OFF (see page C.3). The contact position indicator 7 on the Breaker front provides the user with the correct status of the breaker be it OFF or ON. This indicator is linked to the mechanism and contact system in a manner that allows the device to be used as a Disconnector and to meet the ‘Positive Contact Indication’ requirements. The Breaker Mechanism is of the trip free type and has an integrated anti-pumping system. The front facia also includes room for an optional key interlock device 8 that prevents the breaker from being closed if the key is not inserted and the keylock turned to ‘free’. The interlock device allows a maximum of 4 keylocks to be placed. The breaker can be equipped with up to four factory or fieldMountable releases, 1 x closing coil and a combination of shunt and undervoltage releases being possible. The presence of these releases is made visible on the facia by the use of 4 indicator windows 9 . EntelliGuard™ Power Circuit Breakers are available in two patterns, Fixed and Draw-out. A Fixed device is bolted to a substructure or wall and the power connections are directly fixed to the breaker. A draw-out device has a cassette that is mounted and connected separately. A fixed breaker requires the connection and fixation to be removed to replace the breaker. A breaker in draw-out pattern is supplied as a moving portion, that easily slides in and out of the separately fixed and connected cassette. Each standard device is supplied with 3 NO and 3 NC potential free auxiliary contacts. A IP31 front panel with door escutcheon seal and a IP20 terminal strip or plug 10 with 39 connection points to wire out accessories. B Draw-out Pattern Cassette To dismount a EntelliGuard™ in the Fixed pattern it is required that the power supply is turned ➊ off and the connections are removed. A breaker in ➐ the Draw-out pattern can be quickly and efficiently removed from the system without disconnecting the Power Supply or removing ➌ ➏ ➎ the connections. The Draw-out system ➋ allows easy and simple access to the breaker ➍ and its components and enables the user to fully disconnect the power from the installation for maintenance purposes. Access to the breaker being required for periodic checks and some very limited maintenance allowing the device to be used over its full life span. The cassette 1 is mounted and connected separately and the EntelliGuard™ breaker is supplied as a moving portion that is easily inserted into the cassette. A racking handle 2 is stored within an aperture 3 in the cassette. After removing and unfolding the racking handle and disengaging the blocking mechanism 4 , the handle can be inserted into the ‘racking’ aperture 5 . C D E F X By rotating the racking handle clockwise to move the moving portion inwards (connect) and anti-clockwise to move outwards, (disconnect) the breaker can be racked into one of three positions: CONNECTED Breaker and cassette are fully operational all contacts are connected. TEST The maincontacts are not connected. The Auxiliary contacts are connected. DISCONNECTED The main and auxilary contacts are not connected. The breaker is still inside the cassette. To remove the breaker from the cassette, the racking handle must be removed from the ‘racking’ aperature. A Position indicator 6 provides a positive mechanical indication of the indicated Connected, Test and Disconnected positions. Each EntelliGuard™ cassette has integrated Safety Shutters 7 that automatically isolate the user from live parts when the moving portion is in disconnect or test position. Multiple accessories as carriage position switches, mechanical interlocks, a miss-insertion device, IP54 front protection covers and key lock devices are available (please refer to the relevant sections in this chapter). Each standard cassette is supplied with standard main connections, racking handle, safety shutters and a IP20 terminal socket system with 39 connection points to wire out accessories. (1) Independent of the breaker position (tripped or ON) the device always provides sufficient energy to switch the breaker ‘OFF’ C.2 EntelliGuard™ Electrical Operation of Breaker Connnections The Charging mechanism connection points can be found on terminal A of both the Fixed Pattern & Draw-out Breaker types. A2 Command Closing Coil A second closing coil type is available replacing the standard type. This device offers an extended functionality with all the features of the standard device. Additional connections allow this type to be wired out through the trip unit and to be accessed electrically through the communications bus. It is supplied with an extra ‘ON’ push button that fits onto the breaker front facia. Fitting between the two existing ON and OFF buttons gives the user an extra electrical ‘ON’ option locally. The coils can be used in an operating frequency of up to two operations per minute and have a life span equivalent to that of the full breaker life span. A10 A11 A4 A B OR N A9 D PH Command CC CC C A10 A11 PH READY TO CLOSE OR Intro Connnections The Closing coils & Command closing coils connection points can be found on terminal A of both the Fixed Pattern & Draw-out Breaker types. A3 SPRING CHARGED M A3 SPRING CHARGE MOTOR A1 Closing Coil To switch the Power Circuit Breaker ON remotely a closing coil is available that when energized releases the spring charged closing mechanism. The device is available as a factory mounted component or as a field mountable device. It is an extremely easy-to-fit, clip-on unit, with simple plug-in connectors. The coils have a life span equivalent to that of the full breaker life span. Breaker Use and Operation Electrical Charging mechanism (motor) In order to charge the stored energy mechanism electrically a motor mechanism is available. The design allows factory or field mounting and is available for the full range of EntelliGuard™ breakers. It is easily fitted with just three bolts. When the circuit breaker is opened, the mechanism automatically recharges the springs and prepares the breaker for an almost instantaneous reclosure should the need arise. High speed recharging ensures that the springs are fully charged within four seconds. A “Spring Charged” contact that indicates the status of this device is always present. A 2nd ‘ready to close’ contact is available that indicates that the springs have been recharged and that the breaker can be closed. The device is available in multiple AC & DC voltages and can be used in a operating frequency of up to two operations per minute. it has a life span equivelant to that of the breaker without maintenance. To switch the EntelliGuard™ Breaker ON & OFF remotely a Closing Coil and Shunt Release is also necessary. E A9 A4 F Electrical characteristics Electrical characteristics Control Voltage Motor Operator Envelope 1 Motor Operator Envelope 2 & 3 Power Consumption 24-30V DC, 48V DC, 60V DC, 110-130V DC, 220 - 250V DC 48V AC, 110-130V AC, 220-240V AC, 380-400V AC, 440V AC 300W 480W 350VA 560VA AC DC -48V -110-130V 220-240V 277V 380-415V 440V 24V 48V 60V 110-130V 220-240V 250V --- Power Consumption X 350 VA Inrush C.3 EntelliGuard™ Undervoltage Release A device designed to open the breaker contacts and to prevent the breaker from closing when in a ‘No volt’ condition. On a de-energization the Undervoltage release activates the circuit breaker mechanism and ensures a rapid disconnection of the main contacts (50 Milliseconds). When not re-energized in accordance to the conditions stated in the IEC 60947 the device prevents the Power Circuit Breaker from closing. The EntelliGuard™ Undervoltage releases are designed to react within a pre-defined Voltage band, only reacting when the voltage supplying drops below the limits of this band. To prevent nuisance tripping due to short power interruptions or ‘Brown Outs’ the device has a built in delay of 50 Milliseconds. Two Undervoltage Releases can be mounted in each Power Circuit Breaker. B C D E The device is available as a factory mounted component or as a field mountable device. It is an extremely easy-to-fit, clip-on unit, with simple plug-in connectors. The individual devices have a wide voltage range, thus limiting the number of devices needed and can be used in a operating frequency of up to two operations per minute. The releases can have a life span equivalent to that of the full breakers life span. F X C.4 A8 A5 A13 A5 UV2 A12 ST2 A7 OR A6 A6 Electrical characteristics releases Intro A Connnections The connection points of both releases can be found on terminal A of both the Fixed Pattern & Draw-out Breaker types. As it is possible to mount a total of three of these releases, the connection scheme also includes a 2nd optional UVR or Shunt release. UV1 Shunt Release A device designed to switch the Power Circuit Breaker OFF remotely. When energized a Shunt Release instantaneously activates the circuit breaker mechanism thus ensuring a rapid disconnection of the main contacts (50msec). All EntelliGuard™ Shunt Release are suitable for a continuous power supply and are designed to be used as a closure prevention device when energized. Two Shunt Releases can be mounted in each Power Circuit Breaker. The device is available as a factory mounted component or as a field mountable device. It is an extremely easy-to-fit, clip-on unit, with simple plug-in connectors. The individual devices have a wide voltage range, thus limiting the number of devices needed and have a life span equivalent to that of the full breaker life span. ST1 Breaker Accessories Shunt & Undervoltage Releases AC DC Power Consumption -48V -110-130V 220-240V 277V 380-415V 440V 24V 48V 60V 110-130V 220-240V 250V --- 350 VA / 350 W Inrush 60 VA / 50W Holding Time Delay Module The de-energizing operation of the Undervoltage release can be delayed. This optional, externally mounted module has an adjustable time delay of zero to three seconds. The device can be implemented to prevent undesired Breaker tripping due to momentary voltage interruptions and is connected in series with the Undervoltage release. Optionally, the EntelliGuard™ Trip Unit can be supplied with a three phase plus neutral Undervoltage protection device that can provide a power interruption alarm and/or initiate a breaker ‘trip’. Electrical characteristics releases AC DC Power Consumption 48V --110-130V -220-240V -250-277V 380-415V 440V -48V 60V -110-130V -250V ---- 350 VA Inrush 60 VA Hold EntelliGuard™ Interlock Devices, Indication Contacts and Number of devices Release Indication Contacts To indicate, if a Shunt or an Undervoltage release initiation has resulted in a breaker, OFF or TRIP, a contact can be fitted to the releases. The contacts are available in two versions; one power rated for use in standard Circuits and a second signal rated type for use with the Electronic Trip Unit communication option. The contacts are available as a factory mounted component or as a field mountable device. They are extremely easy-tofit, clip-on units, with simple plug-in connectors. Connnections The connection points of the power rated contacts can be found on terminal B of both the Fixed Pattern & Draw-out Breaker types (2). The Signal rated types are connected to the Electronic Trip Unit and are only accessible through the optional Communication option. Number of devices The EntelliGuard™ Power Circuit Breaker can be equipped with up to 4 of the releases mentioned on pages C2 and C3. Shunt Release (Shunt), Closing & Command closing coils (CC/CCC) and Undervoltage Releases (UVR) can be mounted in the following combinations. The Network Interlock device as described above takes 2 of the indicated 4 spaces. B5 B18 Intro A B ST2/UV2 STATUS CONTACT B19 UV1 STATUS CONTACT B6 ST1 STATUS CONTACT Connnections The device replaces 1 Shunt and 1 Undervoltage release and is wired out to the same connection points located on terminal A of both the Fixed Pattern & Draw-out Breaker types. B17 CC STATUS CONTACT B4 Releases, Interlocks and Contacts Network Interlock Device When devices as the EntelliGuard™ Power Circuit Breaker are used in Automatic or Manaul Power Transfer systems, local access and operation of the device can be undesirable. The Network Interlock Device is an optional mechanical lockout device that can be added to electrically operated circuit breakers. It is a logic driven interlock with two positions, LOCKOUT and RESET. The Network Interlock is locked out and reset by means of voltage pulse applied across respective terminals.(1) Setting the Network Interlock to LOCKOUT when the breaker is closed causes the breaker to trip. In the LOCKOUT position, the Network Interlock holds the breaker mechanically trip free and also inhibits electrical closing. A command to reset the Network Interlock must be provided before the breaker can be closed manually or by control logic. Loss of control power does not cause the Network Interlock to reset. The Network Interlock can also RESET by pushing the reset button provided on the front face of accessory. The device is available as a factory mounted component and has the volume of two releases (Shunt/Undervoltage). OR B7 C B20 D Electrical characteristics Power Rated types AC Ratings E DC Ratings Voltage Amps Voltage Amps 250V AC21-6A 125V 250V DC21-0,4A DC21-0,2A F Minimum Operating Current 0.16 A at 5V DC Coil position on front facia, from left Combination 1 2 3 4 A B C D Network Shunt Shunt Network Interlock Shunt UVR Interlock CC/CCC CC/CCC CC/CCC CC/CCC UVR UVR UVR Shunt X Signal Rated, gold plated contact types AC Ratings DC Ratings Voltage Amps Voltage Amps 125V AC21-0,1A 8-30V DC21-0,1A Minimum Operating Current 1mA at 5V DC (1) Both Coils are not rated for continuous power supply. If needed, the use of a breaker auxiliary contact can be considered to interrupt the lock out coil after operation. The reset coil is equipped with an appropriate contact (see section E) (2) The use of these devices limits the wiring out of some auxiliary contacts (see section E for full schematics) C.5 EntelliGuard™ Connnections (1) The connection points of the Auxiliary contacts can be found on terminal A and of both the Fixed Pattern & Draw-out Breaker types. When the standard 3 NO & 3 NC is required only the standard terminal A is used. Electrical characteristics Auxiliary Contacts Power Rated types D AC Ratings E Voltage 110-130V 220-240V F 380-440V X DC Ratings Amps AC21 - 15A AC23 - 10A AC21 - 10A AC23 - 5A AC21 - 5A AC23 - 2,5A Voltage Amps 24V DC21 -15A 110-130V 250V (3) (2) DC21 -10A DC21 -5A Minimum Operating Current 0,1A at 8V DC Signal Rated, gold plated contact types AC Ratings DC Ratings Voltage Amps Voltage Amps 250V AC21-0,1A 8-30V DC21-0,1A Minimum Operating Current 10 mA at 5V DC (1) The use of these devices limits the wiring out of some auxiliary contacts (see section E for full schematics) (2) Three contacts in series (3) Six contacts in series C.6 NC1 NC2 A20 A22 A24 B24 B26 A21 B17 B19 B6 B4 B20 NC7 B7 A23 NC8 B22 B5 NO1 B25 NO2 B23 NO8 C NC3 B21 NO3 A19 NO4 A17 NO5 A15 B18 Connnections The connection points of the auxiliary contacts can be found on the two terminals (A & B) of both the Fixed Pattern & Draw-out Breaker types. A18 B13 A B A16 B11 The devices are available as factory mounted components or as a field mountable device. Auxiliary contact packages are easy-to-fit, and have simple plug-in connectors. Intro A14 B9 NO7 Auxiliary Contact packages - Power rated contacts 8 NO & 8 NC(1) - Power rated contacts 3 NO & 3 NC plus Signal rated contacts 2 NO & 2 NC - Power rated contacts 4 NO & 4 NC plus Signal rated contacts 4 NO & 4 NC(1) B12 NC4 B10 NC5 B8 NC6 Auxiliary Contacts Auxiliary contacts are designed to indicate the position of the Power Circuit Breaker main contacts. Each EntelliGuard™ device is supplied with a standard package of 3 Normaly open (NO) and 3 normally closed (NC) contacts that operate simultaneously with the breakers main contacts. Optionally other packages are available that can be used to increase the number of available contacts by replacing the standard auxiliary contact block. NO6 Breaker Accessories Auxiliary Contacts A25 EntelliGuard™ Bell Alarm, Cassette position indication, Spring Charged & Ready to close contacts Connnections The connection points of the Bell Alarm contact can be found on terminal A of both the Fixed Pattern & Draw-out Breaker types. A34 A33 Connnections The device is located in the left side of the cassette substructure and can be accessed and connected directly. Electrical characteristics Position Indication Contacts AC Ratings DC Ratings Voltage Amps Voltage Amps 250V AC21-10A 125V 250V DC21-0,5A DC21-0,25A Spring Charged and Ready to Close Contacts A breaker with electrical charging mechanism can be optionally equipped with one or two indication contacts. The first the Spring Charged Contact simply does as indicated and is supplied with the standard Motor Operating Mechanism. The second, the ready to close indication, optionally replaces the Spring Charged Contact. It only moves position when the following conditions are met: BA CONTACTS -> The circuit breaker is open -> The closing springs are charged -> The circuit breaker is not locked/interlocked in open position -> There is no standing closing order -> There is no standing opening order A35 Intro A B Both contacts are availble in a 1NO configuration. Voltage Amps Voltage Amps 250V AC21-6A 125V 250V DC21-0.4A DC21-0.2A Connnections The connection points of these contacts can be found on terminal A of both the Fixed Pattern & Draw-out Breaker types A3 Minimum Operating Current 0,1A at 8V DC Cassette Position Indication Contacts A breaker in draw-out mode has a cassette that is used for mounting and connecting. The breaker, in its moving portion mode, can be inserted into the cassette and by use of the racking handle and it can be moved to one of three positions: Connected, Test, Disconnected or Withdrawn To indicate in which position the EntelliGuard™ Breaker is located within the Cassette position is Indication contacts are available. The disconnected position is only being indicated when minimum isolating distances between contacts on both the main and auxiliary circuits have been achieved. The devices are available in two packages with 1 or 2 changeover contacts per position. Commonly referred to as Carriage switches they are available as a factory mounted component or as a field mountable device. C A3 A4 D READY TO CLOSE DC Ratings SPRINGS CHARGED Electrical characteristics Bell Alarm Contact AC Ratings Bell Alarm & indication contacts Bell Alarm Contact When an EntelliGuard™ Power Circuit Breaker has tripped due to a fault detected by the tripunit, a Bell Alarm Changeover contact is available to indicate this. The Electronic Trip Units trip reason indicators and the optional release indication contacts providing the reason of the ‘trip’. The device is available as a factory mounted component or as a field mountable device. The Bell Alarm contact is easy-to-fit, and has simple plug-in connectors. The contact can only be used when the breaker is adjusted to “manual reset”. OR E A4 Electrical characteristics Power Rated types F AC Ratings DC Ratings Voltage Amps Voltage Amps 250V AC21-6A 125V 250V DC21-0,4A DC21-0,2A X Minimum Operating Current 0.16A at 5V DC Signal Rated, gold plated contact types(1) AC Ratings DC Ratings Voltage Amps Voltage Amps 125V AC21-0,1A 8-30V DC21-0,1A Minimum Operating Current 1mA at 5V DC (1) Spring Charged contact NOT available in signal rated version C.7 EntelliGuard™ Mechanical Interlocking of Multiple Breakers Breaker Accessories Mechanically Interlocked Breakers Many Low Voltage Installations have multiple power sources that are used in many different configurations. The power sources are required to supply the installation simultaneously, alternatively or in a certain logical combinations of both. The EntelliGuard™ Power Circuit Breaker can be used to protect these Power supplies and be electrically and mechanically interlocked to provide the necessary logic. The mechanical interlocks are available for fixed and drawout circuit breakers, enabling the direct interlocking of the breakers, mounted side by side or stacked. The device has two parts; the first a kit customized for use with the breaker in fixed pattern or the cassette when a draw-out pattern is required (field mountable). Two or more specially designed field mountable cables available in lengths of 1,0; 1,6; 2,0; 2,5; 3,0; 3,5 and 4,0 meters being the second. Any combination mode (fixed or draw-out), current rating, number of poles or envelope size can be interlocked. The interlocking systems are available in one configuration for 2 breakers and in three others for 3 breakers. Intro A B C Three Breaker Interlock type B Interlock type B in which one of the three breakers (B1, B2 or B3) can be switched ON. Each breaker must be equipped with a factory mounted interlock type B. Six cables are needed. G B1 B2 B3 Three Breaker Interlock type C Interlock type C in which one or two of the three breakers can be switched ON in accordance with the inserted diagram. Each breaker must be equipped with a factory mounted interlock type C. Six cables are needed. B1 0 I 0 0 I 0 I B2 0 0 0 I I I 0 B3 0 0 I 0 0 I I D Two Breaker Interlock Interlock type A in which one of the two breakers (B1 or B2) can be switched ON. Each breaker must be equipped with a factory mounted interlock type A. Two cables are needed. E F X Three Breaker Interlock type D Interlock type D in which one or two of the three breakers can be switched ON in accordance with the inserted diagram. Breakers B1 & B3 must be equipped with a factory mounted interlock type A and B2 with a interlock type D. Four cables are needed. G B1 C.8 B2 B1 0 I 0 I 0 B2 0 0 0 0 I B3 0 0 I I 0 EntelliGuard™ Locking previsions for Breaker and Cassette Door-Interlock systems; Mis insertion device Standard Padlocking Facilities Breaker & Cassette Cassette Key lock facilities The cassette supplied with the breakers in draw-out mode has three facilities for up to 3 padlocks(1) of 5-8mm. Two of these can be found on the cassette euchenon and can be used for locking the shutters in closed position or closing and locking the racking handle aperture. The third option is located on the breaker draw-out support slides and can be used to lock breaker & chassis combination in disconnected position. Facia Pushbutton Padlocking Facilities To prevent un-authorized access to both the ON and OFF push buttons on the breakers front facia, a padlockable push button cover can be fixed to the breaker front facia. 1 padlock of 5-8mm can be used. Breaker Key lock facilities A Power Circuit breaker can be equipped with up to four key locks. The key lock system encompasses a device fitted in the front facia allowing the locks to be fitted and the separate locks. These devices ensure that a circuit breaker cannot be closed unless the key has been inserted and secured within the lock. Door Interlock Mechanical Interlocking The Cassette of a Power Circuit breaker can be equipped with up to two Ronis or Profalux key locks. The key lock system encompasses a device fitted to the cassette allowing the locks and the separate locks to be fitted. The device ensures that a draw-out circuit breaker cannot be moved from the TEST or DISCONNECT position unless the key has been inserted and secured within the lock. The locks also prevent the breaker from (all positions) being switched on. The device allows up to 2 Ronis 1104 or Profalux locks. The locks must be purchased as separate items. EntelliGuard™ Power Circuit Breakers are supplied with two standard padlocking devices. The breaker in Fixed and Drawout pattern have a padlocking facility for one padlock of 5-8mm allowing the breaker to be locked in its OFF position. Intro A device designed to prevent the door of the equipment in which the breaker is installed to be opened when the Power Circuit breaker is in connected position. It is available in two executions; one for a door opening to the left and one to the right. A B C Mis Insertion Device By incorporating this optional security interlock device into the draw-out cassette, an inadvertent insertion of an incorrect rated moving portion is prevented. Before using the interlocking system, the misinsertion logic needs to be set on both the breaker and the device. D E F X Devices are available for 1 Castell or Kirk lock and 4 Ronis 1104 or Profalux locks. The separate Ronis and ProflAux.locks are part of the EntelliGuard™ product offering the Castell and Kirk locks must be acquired elsewhere. (1) Shutter lock, maximum 1 padlock of 3-8 mm. C.9 EntelliGuard™ Breaker Accessories Installation Accessories Intro A B C D E F X C.10 Operations Counter A simple and easy to install mechanical device that displays an accurate and cumulative record of the number of closing operation of the EntelliGuard™ Power Circuit Breaker in which it is installed. The mechnical and electrical life span of the breaker can be extended by limited periodic maintenance. The counter contains information that can assist in determening when. Contact Wear Indicator A second simple and easy to install mechanical device that can be used to ascertain when breaker maintenance is needed. Mounted above the contacts of a breaker in draw-out mode it allows the user to physically see the contacts and contains markers to determine their wear. Sensors, Rogowski coils If the EntelliGuard™ Electronic Trip Unit is configured to allow Earth/Ground fault protection an external Neutral sensor can be required. Rogowski coils for this application are available as separate items and are supplied with a mounting kit. For the correct sensor choice and application details see page B.14 of this catalogue. Sensors, Current transformers If the EntelliGuard™ Electronic Trip Unit is configured to allow Earth/Ground fault protection an external Neutral sensor can be required. In most standard applications a Rogowski coil suffices, however in some cases other Sensors are needed. Current Transformer are used for ‘Source Ground’ return Earthfault applications. If combinations of earthfault options as UEF, REF & SEF are required multiple sensors could be required. Current Transformers for these application are available as separate item and are supplied with a mounting kit and an extra interposing Current Transformer needed in some specific cases. For the correct sensor(s) choice and application details see page B.14 of this catalogue. Wall Mounting Brackets EntelliGuard™ Power Circuit Breakers are designed to be mounted within a frame inside a low voltage Distribution or Control panel. In some cases, specifically when the front connection option is used, wall mounting can be more expedient. For this purpose wall mounting brackets are available for the breakers in Fixed Pattern, envelope 1 and 2. Terminal Block Breakers in Fixed Pattern, cassettes and breakers in Draw-out mode are always supplied with an auxiliary connection block suitable for 39 connection points (terminal A). When the number of factory installed accessories exceeds the available number of connection points needed, a 2nd connection block is automatically added (terminal B). For cases where the accessories are mounted in the field, separate auxiliary connection block are available; two types suited for the breakers in fixed pattern (39 or 78 pole) and one for breakers in drawout mode (adding 39 poles). IP54 Cover All Power Circuit Breakers are supplied with a door flange/door frame that allows the user to finish the door cut-out professionally, simultaneously providing a protection degree of IP31. If a higher protection degree is required, an additional cover is available allowing IP54. Hoisting/Lifting accessories All EntelliGuard protection devices are equipped with a set of hoisting eyes (see page D.2). To use these hoisting eyes with standard lifting equipment specifically designed adaptors are available. One adaptor or beam is available for use with breakers up to 4000Amps (envelope 1 & envelope 2 types - GLB1) and a second for use with the larger envelope 3 breaker with ratings up to 6400A (GLB3). EntelliGuard™ Earthing device (maintenance accessory) Spare Parts Spare parts for general use The EntelliGuard™ Power Circuit breaker uses components that are designed to last the full life span of the device. However, certain components can be damaged or break during operational use. For these specific cases, the following spare parts are available: Cassette: moving portion Racking Handle (A) Shutters (B) Breaker (C): Front cover Locking devices: Set of 4 Ronis key interlock cams (A) (B) (C) Installation Accessories Earthing Device To allow either the incoming cables or the busbar to be safely held at earthed potential and locked during system maintenance, all EntelliGuard™ Power Circuit Breakers can be fitted with an earthing device. The device is available as a separate field mountable accessory and has a Short-circuit rating equal to the short time withstand (Icw) of the breaker. Intro A B Spare part for maintenace purposes Air Circuit Breakers as the Entellliguard Power Circuit Breakers require periodic maintenance. Here, in some cases certain components critical to the devices functionality could need replacement. Please contact our service department for specialist assistance in establishing which components need replacement and the physical replacement activities. The following items are available: Arc Chutes (A) Fixed arcing Contacts (B) Cassette cluster contacts (C) Pliers to remove Cassette cluster contacts (D) (A) (B) (C) (D) C D E F X C.11 EntelliGuard™ Notes Intro A B C D E F X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EntelliGuard™ Application Guide D.2 Handling, Mounting and Connecting D.4 Heat Dissipation, Watt loss & Current Ratings at temperatures >50°C D.6 Selectivity/Discrimination D.7 Selectivity with downstream devices, tables D.8 Protection of standard circuits D.9 Applications D.10 The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X Environmental considerations D.1 EntelliGuard™ Application Guide Handling, Mounting and Connecting Intro A Clearance distances A modern circuiit breaker is designed to interrupt high Short-circuit currents in a very limted time frame. In doing so the breaker vents gas and a limited amount of conductive fragments. EntelliGuard™ Power Circuit Breakers have been designed to limit the venting phenomenon to a minimum, but certain clearances do need to be taken into account as indicated in the front and side views. The maintenance of the fixed pattern devices requires access to the contacts and the removal of the Arc Chutes. A certain distance needs to be left above the breaker to allow for this as indicated in the front and side views. Front View Fixed or Draw-out Pattern A B1 B2 Minimum Clearance distances on Fixed Pattern breaker from housing to: A(1) B1 B2 Metal Parts Insulated parts 160 30 30 160 30 30 Side View Fixed Pattern 182mm min to remove Arc Chute Minimum Clearance distances from Draw-out cassette housing to: A B1 B2 Metal Parts Insulated parts 0 0 0 0 0 0 B1 (1) Dimension allows for field Arc Chute replacements Handling EntelliGuard™ Breakers in the fixed pattern & as draw-out portion have two retractable lifting eyes. One of these is located on the breaker right hand side and a 2nd on the left (see sketch). The cassettes have four re-enforced tilting points with M10 screw thread. B C D Recommended Connection Cross sections The adjacent table indicates the recommended bus bar dimensions to be used in connecting the EntelliGuard™ Power Circuit Breaker. The current ratings of the devices with these recommended bus bar connection sizes are indicated on page D3 & D4. E F X D.2 Side View Fixed or Draw-out Type Dia 26 Hole Breaker type ‘Automatic’ Switch Type Envelope In in A ‘Non Automatic’ GG04, S N & H GJ04S & GW04N GG04 E and M GJ04H GG07, S N & H GJ07S & GW07N GG07 E and M GJ07H GG08, S N & H GJ08S & GW08N GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GG25N, H & M GJ25N & GW25H GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M GH40N, H & M GG40G & L GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H GK40N & GZ40H GJ40G GG50M & L CJ50L GG64M & L CJ64L 1 or 2 400 1 or 2 630 1 or 2 800 1 or 2 1000 1 or 2 1250 1 2 1 2 1600 2000 2 2500 2 or 3 3200 2 4000 3 4000 3 5000 3 6400 Recommended Copper Bus Bar sizes 1 x 40 x 10 or 1 x 80 x 5 or 2 x 40 x 5 1 x 50 x 10 or 1 x 100 x 5 or 2 x 50 x 5 1 x 50 x 10 or 1 x 100 x 5 or 2 x 50 x 5 1 x 60 x 10 or 2 x 60 x 5 2 x 40 x 10 or 2 x 80 x 5 2 x 50 x 10 or 2 x 100 x 5 3 x 50 x 10 or 3 x 100 x 5 4 x 50 x 10 or 4 x 100 x 5 4 x 100 x 10 4 x 100 x 10 Plus 1 x 100 x 5 4 x 100 x 10 5 x 120 x 10 or 6 x 100 x 10 7 x 120 x 10 or 8 x 100 x 10 EntelliGuard™ Handling, Mounting and Connecting A B C D R6.5 38-42 Nm 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 A B C D 34.5 31 17 Draw-out pattern S type 2000A, N & H 400-2000A 38-42 Nm 50 29 25 Fixed pattern 400-2000A Rear Vertical 15 2 holes Ø 12 Ø 13 Fixed pattern 2000A Rear Horizontal 25 38-42 Nm Ø 12 17 11 .5 R6 A B C D 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 Draw-out pattern S type 400-1600A Rear Vertical or Horizontal 65 22 22 A B C D 25 25 30 17.5 A B C D 3x M10x60 - 8.8 6x M10 6x M10 3x M10 - 8.8 38-42 Nm A B C D R6.5 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 Draw-out pattern 2000A Front 38-42 Nm 15 3x M10x60 - 8.8 6x M10 6x M10 3x M10 - 8.8 65 30 38-42 Nm 30 17 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 38-42 Nm 65 22 22 11 Ø 12 17 17 15,5 A B C D 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 Draw-out pattern 400-1600A Front 65 38-42 Nm 27,5 13 Fixed pattern 400-2000A Front 20 65 18,75 A B C D 8 58 50 Fixed pattern N & H type 400-1600A Rear Horizontal 38-42 Nm 15 2x M10 x 60 -8.8 4x M10 4x M10 2x M10 -8.8 31 17 Fixed pattern S type 400-1600A Rear Horizontal A B C D 3x M10x60 - 8.8 6x M10 6x M10 3x M10 - 8.8 R6.5 58 Handling, Mounting and Connecting Envelope 1 connection modes and application Intro Envelope 2 connection modes and application Ø 13 25 25 25 17 10 A B C D 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 13 A B C D 4 holes Ø 13 100 50-60 Nm 25 25 25 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 A Draw-out pattern 400-4000A Front 12.5 50-60 Nm 25 25 25 Ø 12 20 50-60 Nm 95 Draw-out pattern 400-3200A Rear Vertical or Horizontal 14 Fixed pattern 400-4000A Rear Horizontal or Vertical A B C D 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 B C Draw-out pattern 4000A Rear Vertical ONLY 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 50-60 Nm A B C D 4 holes Ø 13 13 13 A B C D Draw-out pattern - 100% rated version 3200 & 4000A Rear Vertical ONLY 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 15 90 25 25 25 Ø 13 4 holes Ø 13 25 25 25 25 25 25 17 12.5 13 50-60 Nm 100 13 Fixed pattern 400-4000A Front D 50-60 Nm A B C D 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 E 12 58 F Envelope 3 connection modes and application Fixed pattern 4000-5000A Rear Horizontal 30 30 Ø 13 17 14 51 50-60 Nm A B C D 3x M12x60/80 - 8.8 6x M12 6x M12 3x M12 - 8.8 X 50-60 Nm 18 25 25 25 88 Draw-out pattern 4000-5000A Rear Horizontal -OR- 4000 -6400A Rear Vertical (1) A B C D 3x M12x60/80 - 8.8 6x M12 6x M12 3x M12 - 8.8 Ø 13 A B C Fixed pattern 4000-6400A Rear Vertical 50-60 Nm 120 25 25 25 Ø 13 18 A B C D D 4x M12x60/90 - 8.8 8x M12 8x M12 4x M12 - 8.8 (1) The envelope 3 draw-out pattern construction has two connection pads per connection point. D.3 EntelliGuard™ Heat Dissipation, Watt loss & Current Ratings at temperatures >50°C Application Guide Standards The standard for low voltage equipment is defined in the EN 60439-1, the EN 50298 and the IEC 60890. These provide a theoretical method to calculate the temperature rise within an enclosure. The main element in these calculations is the power dissipation of the equipment installed. By totalizing this value for all the installed devices, connections, cables and busbars it is possible to calculate the temperature rise within the enclosure. For normal applications a temperature rise within the enclosure of 50 Kelvin is assumed. Intro A B C D E Breaker type ‘Automatic’ Switch Type ‘Non Automatic’ Envelope In in A Power loss at In per pole (W) GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GG32G & L GG40N, H & M GG40G & L GG50M & L GG64M & L GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GJ32G GJ40N & GW40H GJ40G GJ50L GJ64L 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 3 2 3 3 3 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 4000 4000 5000 6400 2,29 1,66 5,68 4,13 9,15 6,66 14,3 10,4 22,3 16,3 36,6 26,6 57,2 41,6 65,0 106 66,6 166 104 163 266 GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M GH40N, H & M GG40G & L GG50M & L GG64M & L GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H GK40N & GZ40H GJ40G GJ50L GJ64L 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 2 3 2 2 3 3 3 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 4000 4000 4000 5000 6400 4,78 3,74 11,9 9,29 19,1 15,0 29,9 23,4 46,7 36,6 76,5 59,9 120 93,6 146 240 186 106 374 291 166 260 426 Use An enclosure manufacturer can provide the exact data on the allowable power dissipation within a certain enclosure. The values depend on the enclosure type, the ventilation it offers and where the components are located within this enclosure. EntelliGuard™ Power Circuit breakers The devices have been designed to offer the lowest, feasible heat dissipation value and the highest possible current ratings when enclosed. The tables here indicate the heat dissipation values and current ratings at temperatures within the direct vicinty of the breaker in free air. The values apply for breakers used with rear connections and the preferred vertical busbars. The recommended connection cross sections and busbar sizes can be found on page D.2. Temperature in the direct environment of the EntelliGuard ≤50°C 55°C 60°C 65°C 70°C Maximum user Current Ie in A Vertical connection mode: Fixed pattern 400 400 400 400 400 400 400 400 400 400 630 630 630 630 630 630 630 630 630 630 800 800 800 800 800 800 800 800 800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3200 3200 3200 3150 3100 3200 3200 3200 3200 3200 4000 3750 3600 3500 3400 4000 4000 4000 4000 4000 5000 5000 5000 4900 4800 6400 6300 6200 6100 6000 Maximum user Current Ie in A Vertical connection mode: Draw-out types F X D.4 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3800 4000 4000 5000 6400 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3700 3950 4000 5000 6300 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3600 3900 4000 5000 6200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3100 3200 3200 3500 3835 4000 4900 6100 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3000 3200 3200 3400 3750 4000 4800 6000 EntelliGuard™ Heat Dissipation, Watt loss & Current Ratings at temperatures >50°C Breaker type ‘Automatic’ Switch Type ‘Non Automatic’ Envelope GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GG32G & L GG40N, H & M -RH GG40N, H & M-FC GG40G & L GG50M & L GG64M & L GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GJ32G GJ40N & GW40H-RH GJ40N & GW40H-FC GJ40G GJ50L GJ64L 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 3 2 2 3 3 3 In in A Power loss at In per pole (W) 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 2,29 1,66 5,68 4,13 9,15 6,66 14,3 10,4 22,3 16,3 36,6 26,6 57,2 41,6 65,0 106 66,6 Temperature in the direct environment of the EntelliGuard ≤50°C 55°C 60°C 65°C 70°C Maximum user Current Ie in A (2) Horizontal or Front connection mode: Fixed pattern 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3100 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3050 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3000 3200 (1) (1) (1) (1) (1) (1) (1) 4000 4000 5000 166 104 163 4000 4000 5000 3700 4000 5000 3400 4000 5000 3200 4000 4875 3000 4000 4750 (1) (1) (1) (1) (1) (1) (1) Heat Dissipation EntelliGuard™ Power Circuit breakers Other connection modes as rear connection with horizontal busbars and connection from the breaker front are possible. The tables here indicate the heat dissipation values and current ratings at temperatures within the direct vicinty of the breaker in free air. The values apply for breakers used in rear connection mode with horizontal busbar connection and for devices with front connection. The recommended connection cross sections and busbar sizes can be found on page D.2. Intro A B C Maximum user Current Ie in A Horizontal or Front(2) connection mode: Draw-out types GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M -RH GG40N, H & M-FC GH40N, H & M GG40G & L GG50M & L GG64M & L GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H-RH GJ40N & GW40H-FC GK40N & GZ40H GJ40G GJ50L GJ64L 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 2 3 2 2 2 3 3 3 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 4,8 3,74 11,9 9,3 19,1 15,0 29,9 23,4 47 36,6 77 60 120 94 146 240 186 106 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 D 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 2900 3000 3200 (1) (1) (1) (1) (1) (1) (1) 4000 374 4000 3700 3400 3200 3000 (1) (1) (1) (1) (1) (1) (1) 4000 5000 166 260 4000 5000 4000 5000 4000 5000 4000 4850 4000 4700 (1) (1) (1) (1) (1) (1) (1) E F X (1) Rear horizontal connections cannot be used at this current rating (2) Front connections are available for the standard envelope 1 and envelope 2 types (not available for GH,GK and GZ types) D.5 EntelliGuard™ Application Guide Selectivity/Discrimination Intro A B C D E F X D.6 Selectivity - Discrimination In a low voltage distribution network it is necessary that on a fault the protection device nearest to the fault reacts whilst all others remain closed. This capability is called discrimination (UK) or Selectivity (USA and Europe). If this requirement is not met a fault in one arm of the distribution system could cause a number of upstream protection devices to react and open. A relatively minor fault in one arm of a complete distribution will then cause a power interruption across a major part of the installation. Downstream Device Trip Unit Setting Denomination Settings determining selectivity EntelliGuard™ Power Circuit breakers A combination of the high precision and multiple bands of the EntelliGuard™ Electronic Trip Unit allow full selectivity to be achieved between closely rated devices over multiple levels. The table included here indicates the recommended settings of the downstream protection devices and the upstream EntelliGuard™ breaker. A second table on page D.6 indicates the discrimination / selectivity that can be achieved with these settings. The tables can replace the Complex and Time consuming method of comparing multiple Time Current curves across many levels. Recommended EntelliGuard™ settings Ir or Ie setting Ratio LTDB setting band 1,6 x C22 1,6 x C22 Ist setting Ratio STDB setting band 1,6 x Band 2 1,6 x Band 2 1,35 x Band 2 1,35 x Band 3 I setting Record Plus Ir Im Ir FD& FE frame GTM Im Ir LTD line FE frame SMR1 LTD Motor Ist Ir LTD line FG frame SMR1 LTD Motor Ist Ir LTD cl.1.25 LTD cl. 2.5 LTD cl. 5 LTD cl.10 LTD cl.20 FG frame SMR2 LTD cl.30 Ist STD=420ms STD=310ms STD=210ms STD=120ms STD=40ms Ir FK frame SMR1e Ist STD Ir LTD cl. 5 LTD cl.10 LTD cl.20 FK frame SMR1s LTD cl.30 Ist STD=300ms STD=200ms STD=100ms Ir LTD class EntelliGuard GT-E Ist STD band min. until 11 STD band ≤12 Ir LTD class EntelliGuard GT-S, N & H Ist STD band min, until 11 STD band ≤12 Industrial fuses ---Current rating GL/Gg type FD& FE frame LTMD Ratio & Band Ratio & Band Ratio & Band Ratio & Band Ratio & Band Band Band Ratio & Band Ratio & Band Band Band Ratio & Band Ratio Band Band Band Band Band Band Ratio Band Band Band Band Band Ratio & Band Ratio Band Ratio Band Band Band Band Ratio Band Band Band Ratio Band Ratio Band 1,3 x C8 C14 Minimum setting 5kA -FD160, 7kA - FE160, 9kA - FE250 or I = ‘OFF’ 1,3 x C8 C14 1,3 x C3 C5 C8 C12 C16 C18 Minimum setting 14kA -FG400, 18kA - FG630 or use ZSI or I = ‘OFF’ 1,35 x Band 13 Band 11 Band 9 Band 6 Band 3 1,4 x C8 1,35 x Band 7 1,4 x C8 C12 C19 C22 Band 12 Band 10 Band 7 Minimum setting 18kA -FK800 20kA - FK1000 20kA - FK1250 28kA - FK1600 or use ZSI or I = ‘OFF’ 1,25 x 2 higher 1,25 x 2 higher 1 higher Ratio Band Ratio Band 1,25 x Ratio & Band 2x Use ZSI or I = ‘OFF’ 2 higher 1,25 x 2 higher 1 higher F20 ST = 8 x Ir, STDB band 5 and I = 12 x Ie EntelliGuard™ Selectivity with downstream devices, tables Upstream EntelliGuard™ device and Selectivity limit Is (1) Downstream Device GG04S to GG20S GG04N to GG20N GG25N to GG40N GG04E to GG20E GG(H)25H to GG(H)40H GG(H)25M to GG(H)40M GG32G to GG40G GG40M to GG64M GG40L to GG64L All T T T T T T T T T All T T T T T T T T T All T T T T T T T T T All All All All All All All All All All T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T All All All All All All All 50kA (2) 50kA (2) 50kA (2) ----- T 65kA (2) 65kA (2) ----- T 65kA (2) 65kA (2) 65kA (2) 65kA (2) --- T T 85kA (2) ----- T T 85kA (2) 85kA (2) 85kA (2) --- T T 85kA (2) 85kA (2) 85kA (2) --- T T T T T --- T T T T T 100kA (2) 100kA (2) T T T T T 100kA (2) 100kA (2) Intro ---- T T T T T T T T T A Selectivity Elfa Plus MCB’s EP30, 45, 60, 100 & 250, CP30, 45 & 60, DME60, DPE100, DP(A)60, DP(A)100 & DPT100 Elfa Plus MCB’s HTI & S90 C curve Surion Manual Motor starters GPS1BS, GPS1MS & GPS1MH GPS2BS, & GPS2MH Record Plus FD& FE frame C, E, V, S tiers FD& FE frame N tier FD& FE frame H tier FD& FE frame L tier FG frame N tier FG frame H tier FG frame L tier FK frame N tier FK frame H tier FK frame L tier EntelliGuard GG04S to GG20S GG04N to GG20N GG04E to GG20E GG(H)25H to GG(H)40H GG(H)25M to GG(H)40M GG(H)40M to GG(H)64M GG(H)40L to GG(H)64L Industrial fuses GL/Gg type Trip Unit (1) T = Full selectivity until the Icu of the downstream or upstream device (the lowest of the two) (2) Indicated values apply with I (Instantaneous) ON, If Off reduce by 10% B C D E F X D.7 EntelliGuard™ Protection of standard Circuits (1) Application Guide Protection of Standard Circuits Protection devices as the EntelliGuard™ Power Circuit breaker are used in a wide variety of environments to protect conductors, equipment and devices in low voltage distribution circuits. To use this product to its full potential it is necessary to verify that it functions correctly in the environment in which it is used, and that it meets the Electrotechnical requirements of the circuit it protects. Intro A B Environment EntelliGuard™ will function well in almost any industrial environment and fully complies with the environmental requirements of the relevant EN 60 947-2 standard. For conditions other than the above mentioned, please refer to page D.9 of this section. Maximum Short-Circuit Current Each protective device must be capable of interrupting the maximum Short-circuit current at the point where it is installed (see HD 384 standard). The interruption ratings (Breaking Capacities) of the EntelliGuard™ circuit breaker can be found on pages 2, 3 & 4 of this catalogue. Design Current of a circuit The equipment and devices in an electrical circuit determine its current load or design current Ib. A circuit breaker’s overload or Ir setting is normally adjusted to a value equal to the design current. Weakest Short-circuit current in a circuit On a Short-circuit event the total circuit impedance determines both the MAXIMUM and WEAKEST Short-circuit current that can flow in the circuit. For the weakest short circuit current it is necessary to establish if the protection device trips before the electrical conductors reach their maximum temperature, this for operating times of 0,1 to 5 seconds. C D Fault Currents In the 2005 edition of the IEC 60364-4-41 the general terminology ‘Protection against Electrical shock’ has been adapted whilst two new terms have been introduced: E 1) Protection under normal conditions now designated: Basic Protection 2) Protection under fault conditions now designated: Fault protection F X Fault protection being provided by protective equipotential bonding and automatic disconnection of the supply. Under fault conditions, depending on the network an interruption time of 5 seconds (TN) or 1 second is required (TT) for circuits with a rating >32A. Depending on the configuration of the earthing system the 1 and 5 second disconnection time is also required for interruption of a second fault in IT systems. (1) For more details see section E of the 2010 edition of the Record Plus catalogue. D.8 EntelliGuard™ Power Circuit breakers To protect standard circuits, the breakers are equipped with a number of protection devices. Overload Protection device The first is a highly accurate menu driven overload protection device that has an adjustment range of 0,2 to 1 x the breaker rating. Six main current ratings (Ie) are available. Each have a sub setting (Ir) of 0,5 to 1 times the chosen Ie rating. This device is normally set to a value that is equal or closely matches the design current (Ib). Timed Short-circuit Protection Device Set as a multiple of the overload adjustment. this device offers a broad adjustment range of 2 to 12. The setting of this device depends on several parameters as the inrush characteristics of the protected devices. a protection against the weakest Short-circuit current and in some cases against fault currents to earth. 17 narrow and accurate time bands allow the EntelliGuard™ Power Circuit Breaker to interrupt a fault within the timing required by the standards. to offer selectivity across multiple levels and allow the user to take inrush currents into account. Ground Fault Protection It is possible to combine two devices in one. both designed to detect Fault Currents to earth. They can be set as a multiple of the value of the Current Sensors mounted in the breaker and have a broad adjustment range of 0,2 to 1 (0,1 -1 with an auxiliary power supply). The first is a residual device that takes the sum of the current in the three phases and neutral. If this is no longer equal to zero it sends an alarm or trips the breaker. The second allows the user to measure the return current running between the Earth leg and neutral. On detecting a fault to earth the device sends an alarm, or trips the breaker. 14 narrow and accurate time bands allow the EntelliGuard™ G Power Circuit Breaker to interrupt a fault within the timing required by the standards and offer selectivity across multiple levels. Instantaneous Short-circuit Protection Set as a multiple of the primary overload adjustment Ie this device offers a broad adjustment range of 2 to 15 (2-30 on request). This device is normally used to limit the time that higher Short-circuit currents can run in the protected circuit. Whilst the timed Short-circuit protection device waits for a set time, the instantaneous device immediately trips the breaker once the set value is reached. The device used in the EntelliGuard™ Power Circuit Breaker maintains selectivity by only reacting to the 2nd half wave of a Short-circuit current and uniquely allows the use of the ‘Zone Selective Interlock’ feature (see section B). EntelliGuard™ Applications Protection of Generator sets, Motors, Capacitor banks and Transformers Use of EntelliGuard™ Breakers in Automatic Power Transfer Systems (ATS) Remark For an overview of the used abbreviations (as LTDB and STDB) see page B.22. Furthermore, the prevention of anomalies as the motor losing a phase or a motor with blocked rotor need to be prevented and require additional protection devices. Next to the ‘standard’ protection devices the EntelliGuard™ Electronic Trip Unit has a thermal memory function, an optional 3phase Undervoltage relay and current unbalance device thus providing comprehensive motor protection. Protection of Generator sets The overload and Short-circuit devices used to protect a generator need to react quicker and at lower current levels than those used to protect other devices. After establishing the capabilities of the generator set under overload and Short-circuit conditions, the protection devices need to be adjusted accordingly. On a Power Circuit breaker use of the ‘faster’ overload protection bands (LTDB set between Minimum and the C6 band) and a low setting of the timed Short-circuit protection (2.5 x Ir) is recommended. The optional 3 phase Undervoltage protection available in the GT-H trip unit can also be considered. Protection of Capacitor banks Power Circuit breakers are designed to offer high making and breaking capacities under adverse conditions: The switching of capacitor banks has little to no effect on the breaker, its characteristics as a protective device or on its lifespan. However the current flowing in the circuit can trip a circuit breaker and a capacitor load does display certain anomalies. Here the current flowing in the circuit cannot be assumed to be the calculated capacitor current only. The effective current value is higher due to harmonic content (normally assumed as 30%) and an allowance must be made for tolerances in the capacitance of the units (10%). The protection devices of the Power Circuit Breaker must be set accordingly. Protection of Motors On starting electrical Motors draw more current than when running under normal conditions. These starting currents differ strongly per type and should not cause tripping of the device protecting the circuit. Protection of LV/LV Transformers. Transformers generally produce a very high inrush current. The crest values of the first half cycle may reach values of 15 to 25 time the normal rated current. Manufactures data and tests have indicated that a protection device feeding a transformer must be capable of carrying the following current values without tripping. The IEC 60947-4 has defined four different ‘operational’ or ‘Trip’ classes: Required tripping times at Trip class 1.2 x In 1.5 x In 7.2 x In 10A 10 20 30 t < 2 hours t < 2 hours t < 2 hours t < 2 hours t < 2 min. t < 4 min. t < 8 min. t < 12 min. 2 ≤ t < 10 sec. 4 ≤ t ≤ 10 sec. 6 ≤ t ≤ 20 sec. 9 ≤ t ≤ 30 sec. This table is in some cases extended to include a ‘trip class 40’ (assumed to be a 15-40 second band at 7,2 x In). On a Power Circuit breaker, use of the ‘slower’ protection bands that closely match the indicated classes is recommended (LTDB set between the C8 to the C22 band). Switching on a Motor also produces a high but very short inrush peak current which could activate the Short-circuit protection of a breaker and cause unexpected tripping. Here the timed Short-circuit device of a Power Circuit Breaker must be set to at least 12 x Ir with a time delay of 50 Milliseconds (STDB band 3). If an instantaneous protection device is present and switched on, a setting of at least 12 x Ie is recommended. After an overload event the Motor and wiring are still warm, immediate re-energization of the electrical circuit could result in damage of the electrical circuit and the motor. The overload protection device must incorporate a thermal memory device that prevents re-energization before a certain cooling time has elapsed. Protection - Applications Introduction The Electronic Trip Unit used in the EntelliGuard™ Power circuit breaker offers many additional protection devices, a full description of which can be found in section B. Here a number of the possible applications of these devices is described briefly. Intro A B C imum crest inrush values Transformer value 1st period 2nd period After 3 periods < 50 kvA ≥ 50 kvA 25 x In 15 x In 12 x In 8 x In 5 x In 3,5 x In D It is recommended that the timed Short-circuit device of a Power Circuit Breaker is set to at least 8 x Ir with a time delay of 30 Milliseconds (STDB band 1). If an instantaneous protection device is present, the use of the extended adjustment range with setting of 20 x Ie is advisable (=15 x In plus tolerances). E F Automatic Transfer Systems EntelliGuard™ Power Circuit breakers are available with mechanical interlocks for 2 to 3 breakers and have a unique electrical network interlocking system allowing the user to completely lock out one of more breakers. The logical transfer of power from one source to another is thus strongly simplified whilst the high speed electrical closing and opening of the device allows their use in synchronization applications. Here, numerous other EntelliGuard™ protection features can be used, one of which being the Electronic Trip units 3 phase Undervoltage release. This to establish if voltage on a certain power source is present and if a generator set has reached its nominal voltage. X D.9 EntelliGuard™ Environmental Considerations Application Guide Ambient temperature EntelliGuard™ Power Circuit Breakers are designed to operate normally at temperatures of -5 degrees to +70°C. They can be used at temperatures down to -20°C with a reduced electrical and mechanical life span. To prevent materials from reaching temperatures that have an adverse effect on their electrical and/or mechanical properties, de-rating factors must be applied when the device is used in ambient temperatures higher than 50°C. Intro A B C D E F X Storage temperature Power Circuit Breakers can be stored at non operational temperatures of -40 degrees up to +70°C. Influence of Altitude Up to an altitude of 2000m above sea level no de-rating of breaker current or rated voltage is applicable. For altitudes above 2000m the following de-rating factors apply: Harmonics, current dips, interruptions and power frequency variations All EN 60947 Annex F, Sub-clause F4.1 through 3 requirements covering non sinusoidal currents resulting from harmonics are met. Testing covering the following elements: - Wave forms consisting of a fundamental + 3rd harmonic component at 50 and 60Hz - Wave forms consisting of a fundamental + 5th harmonic component at 50 and 60Hz - Composite wave forms with a fundamental component + a 3rd, 5th and 7th harmonic at 50 and 60Hz - Current dips and current interruptions - Frequency variations from 45 to 65Hz in 1 Hz steps Altitude Correction factors Alttitude ≤ 2000M 2500M 4000M Voltage (Ue) Current (In) 1 1 0,95 0,99 0,8 0,96 Other atmospheric conditions The EntelliGuard™ breaker line has been designed to operate at the temperatures and relative humidities defined in the EN 60947 clause 6.1.3.1. They also meet the requirements of the following standards: IEC 68-2-1 IEC 68-2-2 IEC 68-2-3 IEC 68-2-11 IEC 68-2-14 IEC 68-2-30 IEC 721 Cold Dry Heat Damp Heat Salt Change of Temperature Damp Heat cyclic Climatic Shock and Vibration Power Circuit Breakers meet the shock and vibration requirements of the Lloyd’s Register of Shipping, the Germanischer Lloyd and the American Board of shipping. They also meet the requirements of the following standards: IEC 68-2-6 IEC 68-2-27 IEC 68-2-29 IEC 68-2-31 Vibration Shock test Bump Drop test Other All EntelliGuard™ devices meet the existing European ROHS directive and carry the CE mark. D.10 Electromagnetic compatibility The EntelliGuard™ Power Circuit Breaker and its electronic trip unit meet the most stringent requirements off the EN60947-2 and IEC 1004 standard. The following tests have been successfully completed. Electrostatic discharge En 60947 Annex F, Sub-clause F and the IEC 1004-2 - Passed level 4, air discharge 15kV Radiated, radio frequency, electromagnetic field immunity test EN 60947-2 Annex F, Sub-clause F7 and the IEC 1000-4-3 (basic standard) - Passed higher than level 4 …. Field strength 30V/m Electrical fast transient/burst EN 60947-2 Annex F, Sub-clause F5 and the IEC 1000-4-4 (basic standard) - Passed level 4 burst peak voltage 4kV Surge immunity test EN 60947-2 Annex F, Sub-clause F5 and the IEC 1000-4-5 (basic standard) - Passed level 4 Voltage 1,2μs/50μs 6kV; current 8μs/20μs 3kA Dry heat test EN 60947-2 Annex F, Sub-clause F8 - Passed all test requirements Thermal shock test EN 60947-2 Annex F, Sub-clause F9 - No nuisance tripping within the 28-day temperature cycles EntelliGuard™ The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X Wiring Diagrams E.2 Breaker connection schemes Terminal A E.4 Breaker connection schemes Terminal B E.6 Cassette & Trip Unit connection schemes E.7 Trip Unit connection schemes E.1 EntelliGuard™ Breaker Connection Schemes Standard use of Terminal block A One Terminal block A is supplied with each breaker Wiring Diagrams LP1 A1 A3 A5 A7 A9 A12 A14 A16 31 21 A18 11 A20 33 A22 23 A24 96 SPR D1 C3 D1 C2 D2 C4 D2 ST1 UVR1 CC UVR2 A2 A4 98 A6 A8 A10 A13 Intro 22 12 34 24 14 95 T 32 58 A34 BAT C1 ML M2 A33 13 57 M1 User’s designated circuits LP4 A15 A17 A19 LP2 A21 A23 A25 A35 LP3 User’s designated circuits A B Optional use of Terminal block A C Optional use of Terminal block A Used with a Commmand Closing Coil (CCC) Used with a 2nd Shunt Release (Replacing 2nd UVR release) Used with a RTC contact (Replacing SPR contact) D E User’s designated circuits A10 User’s designated circuits A11 User’s designated circuits LP5 A12 A3 F Additional "ON" Pushbutton mounted in breaker front facia. C3 X C1 C5 C4 C2 CCC ST2 A9 58 A13 User’s designated circuits E.2 57 RTC A4 User’s designated circuits User’s designated circuits EntelliGuard™ Optional use of Terminal block A User’s designated circuits A5 66 A7 User designated circuits; indicators LP1: Spring charge status LP2: Breaker open LP3: Breaker closed LP4: Fault LP5: Breaker ready to close Terminology CC: Close coil ST: Shunt release UVR: Undervoltage release SPR: Spring change status RTC: Ready to close status M: Motor operator BAT: Bell alarm trip CCC: Comand close coil NI: Network interlock 68 NI 65 A8 Breaker Connection Schemes Used with a Network Interlock (NI) (Replacing 1 UVR and 1 ST) Intro User’s designated circuits A B C D E F X E.3 EntelliGuard™ Breaker Connection Schemes Standard use of Terminal block B Optional use of Terminal block Wiring Diagrams Terminal block B is supplied with factory mounted breakers, when needed. Used with a Network Interlock (NI) (Replacing 2 NO Aux. Contacts) User’s designated circuits B1 81 B6 71 B8 B10 61 51 B12 41 B17 B19 83 73 B21 63 B23 53 User’s designated circuits LP10 B4 B25 B5 43 66 68 NI 82 72 B5 62 B7 52 B9 B11 42 B13 84 74 B18 64 B20 B22 Intro 54 44 B24 65 B26 B6 User’s designated circuits User’s designated circuits A B Optional use of Terminal block B C Used with Coil indication contacts (Replacing 2 NC and 1 NO Aux. contact) Used with Coil Indication contact (Replacing 1NO Aux. contact) D E LP6 LP7 B4 F X B6 17 27 CC UVR 18 B19 47 ST2 ST1 48 38 B7 B20 B18 User’s designated circuits E.4 User’s designated circuits LP9 B17 37 28 B5 User’s designated circuits LP8 User’s designated circuits EntelliGuard™ Optional use of Terminal block B User’s designated circuits LP9 B19 User designated circuits; indicators LP6: CC powered LP7: UVR not powered LP8: ST powered LP9: ST2 powered/UVR2 not powered LP10: Network interlock lockout 47 Terminology CC: Close coil ST: Shunt release UVR: Undervoltage release SPR: Spring change status NI: Network interlock UVR2 48 Breaker Connection Schemes Used with Coil Indication contact (Replacing 1 NO Aux. Contact) B20 Intro User’s designated circuits A B C D E F X E.5 EntelliGuard™ Cassette & Trip Unit Connection Schemes Optional Cassette Position Indication Switches Wiring Diagrams User’s designated circuits D11 D31 D41 D51 D61 51 61 62 52 54 31 32 12 CONNECTED 64 41 42 34 11 TEST 44 21 22 14 D14 Intro D21 User designated circuits; indicators LP11: Breaker in disconnected position LP12: Breaker in test position LP13: Breaker in connected position D12 DISCONNECTED 24 D24 D34 D22 D32 LP11 D44 D54 D42 D52 LP12 D64 D62 LP13 User’s designated circuits A B Trip Unit - Type GT-E C D A32 A31 A36 A37 E F 24V+ 24V- N - RC - +24VVDC X N E.6 N - RC + Terminology 24V+/24V-: N-RC: RXD: TXD: TX_EN_I: 5V ISO: ISO GND: ELCT: RELAY O/P: RELAY I/P: V-A/V - B/V-C: GND: ZSI OUT: ZSI IN: Auxiliary power supply to trip unit Neutral Rogowski coil Modbus/Profibus communication Modbus/Profibus communication Profibus communication Profibus communication Profibus communication Earth leg ct Relay OUT PUT Relay IN PUT Signal input from voltage conditioner Ground for voltage Zone selective interlock OUT Zone selective interlock IN EntelliGuard™ Trip Unit Connection Schemes A31 A32 A36 A37 B27 B28 B29 B30 24+ 24- N-RC N-RC ZSI OUT+ ZSI OUT- ZSI IN+ ZSI IN- - Trip Unit Connection Schemes Trip Unit - Type GT-S + +24VDC + - ZSI N + - ZSI COMMUNICATION TX RX TX Intro RX A B35 B34 B Trip Unit - Type GT-N A31 A32 A36 C A27 A37 A28 A29 B1 A30 B2 B3 B27 B28 B29 D B30 E (1) 24V- 24V+ N-RC - +24VVDC N-RC (1) RELAY + O/P 1 RELAY TU O/P 2 97 98 07 RELAY 08 ZSI OUT+ IP I1 TU I2 TU ICOM + ZSI OUT- ZSI ZSI IN+ + ZSI INZSI F - N SIGNAL INPUT FROM VOLTAGE CONDITIONER V-C U3 V-B U2 B39 B38 V-A U1 B37 X COMMUNICATION GND UCOM B36 TX TX B35 RX RX B34 (1) Relay output one and electronic input one are assigned to RELT function. E.7 EntelliGuard™ Trip Unit Connection Schemes Wiring DIagrams Trip Unit - Type GT-H A27 A28 A29 A30 A31 A32 A36 A37 RELAY O/P 1 RELAY O/P 2 24V+ 24V- N-RC N-RC A38 A39 (1) -TU ELCT + N +24VVDC TU N 97 98 07 08 Intro B1 B2 B3 B27 B28 B29 B30 ZSI OUT+ ZSI OUT- ZSI IN+ ZSI IN- A (1) B I/P RELAY I2 I1 ICOM + TU ZSI - + ZSI - C SIGNAL INPUT FROM VOLTAGE CONDITIONER D V-C U3 V-B U2 V-A U1 COMMUNICATION TX GND UCOM TX RX RX TX_EN_I EN 5V ISO ISO GND 5V E E B39 B38 B37 B36 B35 B34 Terminology 24V+/24V-: N-RC: RXD: TXD: TX_EN_I: 5V ISO: ISO GND: ELCT: RELAY O/P: RELAY I/P: V-A/V - B/V-C: GND: ZSI OUT: ZSI IN: X (1) Relay output one and electronic input one are assigned to RELT function. E.8 B33 B32 B31 Auxiliary power supply to trip unit Neutral Rogowski coil Modbus/Profibus communication Modbus/Profibus communication Profibus communication Profibus communication Profibus communication Earth leg CT Relay OUT PUT Relay IN PUT Signal input from voltage conditioner Ground for voltage Zone selective interlock OUT Zone selective interlock IN EntelliGuard™ Dimensions F.2 Envelope 1 - Fixed type F.3 Envelope 1 - Draw-out type F.4 Envelope 2 - Fixed type F.5 Envelope 2 - Draw-out type F.6 Envelope 2 - 100% rated Draw-out type F.7 Envelope 1 & 2 - Optional Connection modes F.8 Envelope 3 - Fixed type F.10 Envelope 3 - Draw-out type F.12 IP54 Flange, Time Delay Module UVR, 24V Power Supply F.13 Rogowski’s, Current Transformers, The breaker Intro Order Codes A Electronic Trip Units B Breaker Accessories C Application Guide D Wiring Diagrams E Dimensions F Numerical index X Door interlock system & wall mounting brackets F.14 Interlocking with cable systems, 2 way F.15 Interlocking with cable systems, 3 way F.1 EntelliGuard™ Envelope 1 - Fixed Pattern Front view 4pole Front view 3pole Centre Line of operating panel 423 323 Side view Centre Line of operating panel door B 160 260 348 442 Centre Line of operating panel 38 213 213 Dimensions Centre Line of operating panel 91 14 50 131.5 162 172 131.5 131.5 261 175 211 100 to door 131.5 162 161 172 443 127 355 343 Top view 4pole Intro 61 100 100 Door Cut-out 100 12,5 66,5 A 308 150 of breaker of fascia Ø4 A Left mounting hole location of breaker viewed from front Top view 3pole 61 D 100 B 367 392 C 141,5 283 100 A Breaker type Envelope 1 3 pole Envelope 1 4 pole 100 E A 12,5 C 30 74 door 183,5 219 100 B Door hinge DIM “A” 20,0 20,0 DIM “B” minimum 55,0 55,0 DIM “C” 0,0 -49,5 door F X Standard Connection pads(1) 2000A Types S, N & H 65 65 22 22 27,5 11 15,5 5 R6. Remarks Ø 12 17 17 107 35 400 - 1600A Types N & H 17 123 25 F.2 18,75 50 29 13 20 400 - 1600A Type S A - 6 mounting holes of Ø 9,5mm B - Please refer to section D for clearance distances EntelliGuard™ Envelope 1 - Draw-out Pattern Front view 4pole Front view 3pole 173.5 194 443 Centre Line of operating panel Centre Line of operating panel 194 D 124 172 387 to door Centre Line of operating panel 235.5 Centre Line of operating panel 172 Side view 343 443 53 131.5 131.5 131.5 Top view 4pole 368 Door Cut-out 55 31 Centre Line of operating 233.5 panel C 308 150 of cassette Intro of fascia Ø4 267 247 12,5 66,5 Envelope 1 131.5 32 Test 52 Disconnected 422 Connected 350 Fully withdrawn 100 Left mounting hole location of cassette viewed from front Top view 3pole 268 Centre Line of operating panel 133.5 150 405 430 127,5 58 100 100 9,5 52,5 58 71.5 A C 141,5 A B B 12,5 90 6 holes Ø 9.6 300 Door hinge C 283 55 31 C DIM “A” -7,0 -7,0 DIM “B” minimum 60,0 60,0 D DIM “C” 0,0 -49,5 247 247 Breaker type Envelope 1 3 pole Envelope 1 4 pole E 90 Remarks 58 71.5 100 58 100 Universal Connection pads Mounted Horizontally or Vertically Universal Connection pads Details S type N & H type 2 holes Ø 12 15 65 43 123 61 S, N & H type 11 123 107 61 65 25 11 43 S, N & H type 58 R6.5 S type - 12mm thick F X 15 30 17.5 84.5 123 111 4 holes Ø 12 61 A - 6 mounting holes of Ø 9,5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing 31 17 A 8 58 N & H type - 20mm thick F.3 EntelliGuard™ Envelope 2 - Fixed Pattern Front view 4pole Front view 3pole 410 540 319 door B Centre Line of operating panel 190 Centre Line of operating panel Dimensions 38 213 213 Centre Line of operating panel 348 442 Centre Line of operating panel Side view 91 14 50 131.5 222 234 131.5 191 131.5 222 234 131.5 321 175 211 100 to door 436 566 127 355 Top view 4pole Door Cut-out 76 130 130 130 Intro 12,5 66,5 308 150 of breaker of fascia Ø4 A A 76 D 130 130 A Breaker type Envelope 2 3 pole Envelope 2 4 pole door E C 141,5 283 A B DIM “A” 80,0 80,0 12,5 183,5 219 Left mounting hole location of breaker viewed from front Top view 3pole 30 74 B C 367 392 Door hinge door DIM “B” minimum 115,0 115,0 DIM “C” 15,5 -49,5 F Standard Connection pads X 95 25 25 25 Ø 13 Remarks 17 20 10 107 123 A - 6 mounting holes of Ø 9,5mm B - Please refer to section D for clearance distances 35 F.4 EntelliGuard™ Envelope 2 - Draw-out Pattern 573 387 to door 443 Centre Line of operating panel D 194 194 173.5 Centre Line of operating panel 443 Centre Line of operating panel 124 237 235.5 Centre Line of operating panel 237 Side view Front view 3pole Front view 4pole 131.5 53 131.5 131.5 Top view 4pole 488 Door Cut-out 55 31 Centre Line of operating panel 293.5 C 267 247 12,5 66,5 308 150 Envelope 2 131.5 32 Test 52 Disconnected 422 Connected 350 Fully withdrawn of cassette of fascia Ø4 Intro 90 Door hinge Top view 3pole Left mounting hole location of cassette viewed from front 358 Centre Line of operating 163.5 panel 55 31 A A 127,5 130 C 141,5 B B 12,5 130 150 405 430 58 130 9,5 52,5 58 91.5 300 A 283 C 267 247 C DIM “A” 53,0 53,0 DIM “B” minimum 125,0 125,0 DIM “C” 15,5 -49,5 D 90 Breaker type Envelope 2 3 pole Envelope 2 4 pole A 58 E 58 91.5 130 130 Universal Connection pads Vertical or Horizontal max. 3200A F Universal Connection pads Only Vertical max. 4000A 64 133 123 11 62 25 25 25 Remarks 29 21 21 10 84.5 13 107 14 123 X 61 95 100 25 25 25 4 holes Ø 13 4 holes Ø 11 10 59 11 45 20 100 78 4 holes Ø 11 11 78 13 13 100 78 100 11 78 11 4 holes Ø 13 A - 6 mounting holes of Ø 9,5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing 15 90 F.5 EntelliGuard™ Envelope 2 - 100% rated Draw-out Pattern Front view 4pole 387 to door 443 Centre Line of operating panel Dimensions 194 194 Centre Line of operating panel 131.5 53 131.5 131.5 131.5 32 Test 52 Disconnected 422 350 Fully withdrawn Top view 4pole 488 55 31 Centre Line of operating panel 293.5 Door Cut-out C 12,5 66,5 267 247 Intro D 443 237 124 Centre Line of operating panel Centre Line of operating panel 174 236 573 237 Side view Front view 3pole 308 150 of cassette of fascia Ø4 90 Door hinge A 130 Top view 3pole Left mounting hole location of cassette viewed from front 358 Centre Line of operating 163.5 panel E 283 267 A 58 92 F DIM “A” 53,0 53,0 DIM “B” minimum 125,0 125,0 DIM “C” 15,5 -49,5 58 130 130 Universal Connection pads Vertical max. 4000A 32 21 21 10 X Breaker type Envelope 2 3 pole Envelope 2 4 pole 90 D B C 141,5 C 247 55 31 C A 12,5 B 130 127,5 58 130 9,5 52,5 58 92 150 405 430 300 A 11 Remarks 11 11 F.6 4 holes Ø 13 84 A - 6 mounting holes of Ø 9,5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing 133 112 25 25 25 13 13 105 105 84 4 holes Ø 11 100 12 58 EntelliGuard™ Envelope 1 & 2 - Alternate Connection Modes Fixed Vertical Rear Connection Envelope 1 Fixed Vertical Rear Connection Envelope 2 MAX. 3200A 4000A Details max. 3200A 100 20 Ø 13 12.5 25 25 25 95 34.5 31 15 100 25 25 25 12.5 100 157 70.5 91 15 Details max. 4000A 10 10 10 100 100 157 70.5 71 63 Ø 13 20 Envelope 1 and 2 157 130 Ø 13 13 130 50 Intro Fixed Front Connection Envelope 1 ≤1600A Fixed Front Connection Envelope 1 2000A Draw-out Front Connection Envelope 1 ≤1600A A 10 10 B 65 65 30 .5 R6 25 20 17 R6.5 453 25 C R6.5 D 76 110 96 68 13 13 17 25 65 30 30 565 453 10 10 10 13 E Draw-out Front Connection Envelope 1 2000A Fixed Front Connection Envelope 2 10 10 10 566 100 100 12.5 Ø 13 25 25 25 Ø 12 20 17 Ø 12 25 25 25 68.5 12.5 13 20 X 453 565 68 65 22 22 F 12.5 12.5 12.5 12.5 12.5 12.5 10.5 33 Draw-out Front Connection Envelope 2 96 67.5 100.5 F.7 EntelliGuard™ Envelope 3 - Fixed Type Front view 4pole Front view 3pole 715 945 Centre Line of operating panel 465 350 Centre Line of operating panel 213 Centre Line of operating panel 213 Dimensions Centre Line of operating panel 131.5 131.5 131.5 479 491 131.5 348 364 376 464 736 966 Intro A Top view 4pole Top view 3pole B 68.5 115 115 115 115 115 115 115 69 115 115 115 115 115 C A E F X F.8 door 100 100 D A door EntelliGuard™ Envelope 3 - Fixed Type Side view Door Cut-out B 12,5 66,5 308 150 of breaker of fascia Ø4 91 14 Left mounting hole location of breaker viewed from front 127 A B 367 392 183,5 C 141,5 283 12,5 175 211 100 to door 30 74 50 Envelope 3 38 219 348 442 Door hinge 355 Breaker type Envelope 3 3 pole Envelope 3 4 pole DIM “A” 222,5 337,5 DIM “B” minimum 259,5 374,5 DIM “C” 8,0 8,0 Intro A B Standard Connection pads Vertictal maximum 6400A C 230 90 20 120 20 Standard Connection pads Horizontal maximum 5000A D 123 157 60.5 E F 107 Ø 13 120 35 14 30 30 Ø 13 X 18 17 88 25 25 25 165 Remarks A - 6 mounting holes of Ø 9,5mm B - Please refer to section D for clearance distances F.9 EntelliGuard™ Envelope 3 - Draw-out Pattern Front view 4pole Front view 3pole 743 Centre Line of operating panel 973 Centre Line of operating panel 479 364 Centre Line of operating panel 194 194 Dimensions Centre Line of operating panel 131.5 131.5 131.5 Top view 4pole Intro Top view 3pole 884 654 639.5 244.5 C Centre Line of operating panel 319.5 C 129.5 C 58 D E F X F.10 141.5 58 230 230 230 267 120 A 247 267 A 120 B 247 55 31 55 A 524.5 434.5 31 Centre Line of operating panel 131.5 A 58 141.5 58 230 230 EntelliGuard™ Envelope 3 - Draw-out Pattern Side view Door Cut-out 419 to door 12,5 66,5 308 150 of cassette of fascia Ø4 D 150 405 430 300 443 Left mounting hole location of cassette viewed from front 32 Test 52 Disconnected 454 Connected A 127,5 C 141,5 12,5 9,5 52,5 235.5 85 Envelope 3 B 283 DIM “A” 193,5 308,5 DIM “B” minimum 267,0 382,0 350 Fully withdrawn Intro Breaker type Envelope 3 3 pole Envelope 3 4 pole DIM “C” 8,0 8,0 A B Standard Connection pads Horizontal maximum 5000A Standard Connection pads Vertictal maximum 6400A C 90 51 18 68 Ø 13 18 12.5 102.5 25 25 25 25 25 25 70.5 68 D E 157 169.5 100 20 55 20 104 173.5 124 Door hinge F X Ø 13 Remarks A - 6 mounting holes of Ø 9,5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing F.11 EntelliGuard™ IP54 Flange, Time Delay Module UVR, 24V Power Supply IP54 Flange IP54 Flange drilling Ø 5.3 4-Places Intro A 405 22.5 Dimensions 30 295.5 474 30 140 386 Time delay Module (UVR) Mtg to suit 35mm DIN Rail 79.5 2 holes Ø 4.5 5.15 42 90 35 D Centre Line of operating panel 35.5 B C 283 12 5.75 67 69.5 81 E F External 24V DC Power Supply 54321 115 X 6 7 29 F.12 76 EntelliGuard™ Rogowski’s, Current Transformers, Door Interlock system and Mounting Brackets Rogowski Coil external Current Transformer external Arrow to face ACB connection Ø1D (min) HT (max) Ø0D (min) 58 Rating 400A 630A 2000A 3200A 4000A 5000A 6400A 1D 94 85 87 84 81 85 85 0D 144 135 151 154 154 198 210 Accessories Fix coil to clamp with cable ties (position coil centrally on clamp) HT 24 30 31 34 57 58 65 110 Remark: for ratings > 4000A two coils are used Intro Door Interlock system A 183.5 283 B Centre of operating panel A 20 405 B 198 4 holes Ø 6.4 Frame F1-3P F1-4P F2-3P F2-4P F3-3P F3-4P A 33.5 33.5 98.5 98.5 240.5 355.5 B 32.5 132.5 67.5 197.5 225.5 340.5 C D E Front mounting brackets (fixed pattern, drawings include front connection option) Envelope 1 Envelope 2 A F E Centre Line of operating panel Centre Line of operating panel B F Centre Line of operating panel Centre Line of operating panel 4 holes Ø 12.2 131.5 159.5 172.5 131.5 C D 3 pole 320 159,5 158,5 344 410 189,5 190 437 4 pole 420 259,5 258,5 444 540 319,5 320 567 X 17 102 4 holes Ø 12.2 A B C D E F G H 131.5 221 234 131.5 G H F.13 EntelliGuard™ Interlocking with Cable systems; 2 way Fixed pattern 2-way cable interlock / Fixed pattern - Front/rear access 2000 max. 50 Intro A 35 140 min. Dimensions 55 900 max. vertical base to base Envelope 1-3P=320 Envelope 1-4P=420 Envelope 2-3P=410 Envelope 2-4P=540 Envelope 3-3P=715 Envelope 3-4P=945 50 Min. bend radius 120 30 30 Min. bend radius 120 B C Draw-out 2-way cable interlock / Withdrawable pattern - Front/rear access 2000 max. Envelope 1-3P=343 Envelope 1-4P=443 Envelope 2-3P=443 Envelope 2-4P=573 Envelope 3-3P=743 Envelope 3-4P=973 E 60 900 max. vertical base to base D F 40 Min. bend radius 120 F.14 34 34 X Min. clearance below cassette 140 min. Min. clearance below cassette 30 Min. bend radius 120 30 EntelliGuard™ Interlocking with Cable systems; 3 way Fixed pattern 3-way cable interlock / Fixed pattern - Front/rear access 1250 max. Accessories 900 max. vertical base to base 55 140 min. Envelope 1-3P=320 Envelope 1-4P=420 Envelope 2-3P=410 Envelope 2-4P=540 Envelope 3-3P=715 Envelope 3-4P=945 Min. bend radius 120 Intro A B Draw-out 3-way cable interlock / Withdrawable pattern - Front/rear access 65 1250 max. Envelope 1-3P=343 Envelope 1-4P=443 Envelope 2-3P=443 Envelope 2-4P=573 Envelope 3-3P=743 Envelope 3-4P=973 C D 65 E F X Min. bend radius 120 140 min. clearence below cassette 55 55 30 F.15 EntelliGuard™ Ref. No. Cat. No. Page Ref. No. A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 407134 407135 407136 407137 407138 407139 407150 407151 407152 407153 407154 407155 407156 407157 407158 407159 407160 407161 407162 407163 407164 407165 407166 407167 407168 407169 407190 407191 407192 407193 407194 407195 407196 407197 407198 407199 407200 407201 407202 407203 407204 407205 407206 407207 407208 407209 407230 407231 407232 407233 407234 407235 407236 407237 407238 407239 407240 407241 407242 407244 407245 407248 407249 407250 407251 407252 407253 407254 407255 407260 407261 407262 407263 407264 407265 407266 407267 407268 407269 407270 407271 407273 407278 407279 407280 407281 407282 407283 407284 407285 407286 407287 407288 407289 407290 Numerical index 407000 Intro A B C D E F X X.1 407001 407002 407003 407004 407005 407006 407007 407008 407009 407010 407011 407012 407013 407014 407015 407016 407017 407018 407019 407020 407030 407031 407032 407033 407034 407035 407036 407037 407038 407039 407040 407041 407042 407043 407044 407045 407046 407047 407048 407049 407060 407061 407062 407063 407064 407065 407066 407067 407068 407069 407070 407071 407072 407073 407074 407075 407076 407077 407078 407079 407090 407091 407092 407093 407094 407095 407096 407097 407098 407099 407100 407101 407102 407103 407104 407105 407106 407107 407108 407109 407120 407121 407122 407123 407124 407125 407126 407127 407128 407129 407130 407131 407132 407133 GG04E1 GG04E3 GG04E4 GG04E6 GG04H1 GG04H3 GG04H4 GG04H6 GG04M1 GG04M3 GG04M4 GG04M6 GG04N1 GG04N3 GG04N4 GG04N6 GG04S1 GG04S3 GG04S4 GG04S6 GG07E1 GG07E3 GG07E4 GG07E6 GG07H1 GG07H3 GG07H4 GG07H6 GG07M1 GG07M3 GG07M4 GG07M6 GG07N1 GG07N3 GG07N4 GG07N6 GG07S1 GG07S3 GG07S4 GG07S6 GG08E1 GG08E3 GG08E4 GG08E6 GG08H1 GG08H3 GG08H4 GG08H6 GG08M1 GG08M3 GG08M4 GG08M6 GG08N1 GG08N3 GG08N4 GG08N6 GG08S1 GG08S3 GG08S4 GG08S6 GG10E1 GG10E3 GG10E GG10E6 GG10H1 GG10H3 GG10H4 GG10H6 GG10M1 GG10M3 GG10M4 GG10M6 GG10N1 GG10N3 GG10N4 GG10N6 GG10S1 GG10S3 GG10S4 GG10S6 GG13E1 GG13E3 GG13E4 GG13E6 GG13H1 GG13H3 GG13H4 GG13H6 GG13M1 GG13M3 GG13M4 GG13M6 GG13N1 GG13N3 By reference number Cat. No. GG13N4 GG13N6 GG13S1 GG13S3 GG13S4 GG13S6 GG16E1 GG16E3 GG16E4 GG16E6 GG16H1 GG16H3 GG16H4 GG16H6 GG16M1 GG16M3 GG16M4 GG16M6 GG16N1 GG16N3 GG16N4 GG16N6 GG16S1 GG16S3 GG16S4 GG16S6 GG20E1 GG20E3 GG20E4 GG20E6 GG20H1 GG20H3 GG20H4 GG20H6 GG20M1 GG20M3 GG20M4 GG20M6 GG20N1 GG20N3 GG20N4 GG20N6 GG20S1 GG20S3 GG20S4 GG20S6 GG25H1 GG25H3 GG25H4 GG25H6 GG25M1 GG25M3 GG25M4 GG25M6 GG25N1 GG25N3 GG25N4 GG25N6 GG32H1 GG32H4 GG32H6 GG32L1 GG32L3 GG32G1 GG32G3 GG32G4 GG32G6 GG32L4 GG32L6 GG32M1 GGM3M3 GG32M4 GG32M6 GG32N1 GG32N3 GG32N4 GG32N6 GG40G1 GG40G3 GG40G4 GG40G6 GG32H3 GG40H1 GG40H3 GG40H4 GG40H6 GG40L1 GG40L3 GG40L4 GG40L6 GG40M1 GG40M3 GG40M4 GG40M6 GG40N1 Page Ref. No. A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.4 A.4 A.8 A.8 A.8 A.8 A.4 A.4 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 407291 407292 407293 407300 407301 407302 407303 407304 407305 407306 407307 407320 407321 407322 407323 407324 407325 407326 407327 407346 407347 407348 407349 407350 407351 407352 407353 407354 407355 407356 407357 407374 407375 407376 407377 407378 407379 407380 407381 407394 407395 407396 407397 407398 407399 407400 407401 407414 407415 407416 407417 407418 407419 407420 407421 407434 407435 407436 407437 407438 407439 407440 407441 407454 407455 407456 407457 407458 407459 407460 407461 407474 407475 407476 407477 407478 407479 407480 407481 407494 407495 407496 407497 407498 407499 407500 407501 407518 407519 407520 407521 407533 407534 407535 407536 Cat. No. GG40N3 GG40N4 GG40N6 GG50L1 GG50L3 GG50L4 GG50L6 GG50M1 GG50M3 GG50M4 GG50M6 GG64L1 GG64L3 GG64L4 GG64L6 GG64M1 GG64M3 GG64M4 GG64M6 GH32H1 GH32H3 GH32M1 GH32M3 GH32N1 GH32N3 GH40H1 GH40H3 GH40M1 GH40M3 GH40N1 GH40N3 GW04N1 GW04N3 GW04N4 GW04N6 GJ04S1 GJ04S3 GJ04S4 GJ04S6 GW07N1 GW07N3 GW07N4 GW07N6 GJ07S1 GJ07S3 GJ07S4 GJ07S6 GW08N1 GW08N3 GW08N4 GW08N6 GJ08S1 GJ08S3 GJ08S4 GJ08S6 GW10N1 GW10N3 GW10N4 GW10N6 GJ10S1 GJ10S3 GJ10S4 GJ10S6 GW13N1 GW13N3 GW13N4 GW13N6 GJ13S1 GJ13S3 GJ13S4 GJ13S6 GW16N1 GW16N3 GW16N4 GW16N6 GJ16S1 GJ16S3 GJ16S4 GJ16S6 GW20N1 GW20N3 GW20N4 GW20N6 GJ20S1 GJ20S3 GJ20S4 GJ20S6 GJ25N1 GJ25N3 GJ25N4 GJ25N6 GJ32L1 GJ32L3 GJ32L4 GJ32L6 Page Ref. No. A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 407537 407538 407539 407540 407554 407555 407556 407557 407558 407559 407560 407561 407565 407566 407567 407568 407575 407576 407577 407578 407589 407590 407591 407592 407593 407594 407595 407596 407606 407607 407610 407612 407613 407615 407616 407617 407618 407619 407620 407622 407623 407625 407626 407627 407628 407629 407630 407632 407633 407635 407636 407637 407640 407642 407643 407645 407650 407652 407654 407656 407658 407666 407668 407670 407679 407680 407686 407688 407700 407701 407702 407703 407704 407705 407706 407707 407708 407709 407710 407711 407712 407713 407714 407715 407716 407717 407718 407719 407725 407726 407727 407728 407729 407730 407731 Cat. No. GJ32N1 GJ32N3 GJ32N4 GJ32N6 GJ40L1 GJ40L3 GJ40L4 GJ40L6 GJ40N1 GJ40N3 GJ40N4 GJ40N6 GJ50L1 GJ50L3 GJ50L4 GJ50L6 GJ64L1 GJ64L3 GJ64L4 GJ64L6 GZ32H1 GZ32H3 GK32N1 GK32N3 GZ40H1 GZ40H3 GK40N1 GK40N3 G20H2SSL G20H5SSL GG16H2FR GG16H2UR GG16H5FR GG16H5UR GG16S2UM GG16S2UR GG16S5UM GG16S5UR GG20H2FR GG20H2UR GG20H5FR GG20H5UR GG16S2FM GG16S2FR GG16S5FM GG16S5FR GG20M2FR GG20M2UR GG20M5FR GG20M5UR G40M2SSL G40M5SSL GG25M2FR GG25M2UR GG25M5FR GG25M5UR GG32M2FR GG32M2UR GG32M5FR GG32M5UR GG40M2FR GG40M2UR GG40M5FR GG40M5UR G64L2SSL G64L5SSL GG64L2UR GG64L5UR GM01024D GM01024DR GM01048D GM01048DR GM01060D GM01060DR GM01110D GM01110DR GM01250D GM01250DR GM01048A GM01048AR GM01120A GM01120AR GM01240A GM01240AR GM01400A GM01400AR GM01440A GM01440AR GM02024D GM02024DR GM02048D GM02048DR GM02060D GM02060DR GM02110D Page A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.28 A.28 A.25 A.25 A.25 A.25 A.11 A.25 A.11 A.25 A.25 A.25 A.25 A.25 A.11 A.25 A.11 A.25 A.25 A.25 A.25 A.25 A.28 A.28 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.28 A.28 A.25 A.25 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 EntelliGuard™ Ref. No. Cat. No. GM02110DR GM02250D GM02250DR GM02048A GM02048AR GM02120A GM02120AR GM02240A GM02240AR GM02400A GM02400AR GM02440A GM02440AR GNTK120 GNTK240 GSTR024D GSTR024DR GSTR048 GSTR048R GSTR060D GSTR060DR GSTR120 GSTR120R GSTR240 GSTR240R GSTR277 GSTR277R GSTR400A GSTR400AR GSTR440A GSTR440AR GUVT024D GUVT024DR GUVT048 GUVT048R GUVT060D GUVT060DR GUVT120 GUVT120R GUVT240 GUVT240R GUVT277 GUVT277R GUVT400A GUVT400AR GUVT440A GUVT440AR GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM277A GTDM250D GTDM400A GTDM440A GCCC024DR GCCC024D GCCC048R GCCC048 GCCC060DR GCCC060D GCCC120R GCCC120 GCCC240R GCCC240 GCCC277 GCCC277R GCCC400AR GCCC400A GCCC440A GCCC440AR GCCN024DR GCCN024D GCCN048R GCCN048 GCCN060DR GCCN060D GCCN120R GCCN120 GCCN240R GCCN240 GCCN277 GCCN277R GCCN400AR GCCN400A GCCN440A GCCN440AR GAS3R GAS5R GAS6R GAS8R GAS5 GAS6 Page Ref. No. A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.17 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.17 A.20 A.20 A.17 A.17 A.20 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.17 A.20 A.20 A.17 A.17 A.20 A.20 A.20 A.20 A.20 A.17 A.17 407888 407889 407891 407894 407895 407896 407897 407899 407900 407901 407902 407903 407904 407905 407906 407907 407915 407916 407922 407923 407924 407925 407930 407931 407932 407933 407934 407935 407936 407937 407967 407968 407970 407971 407974 407976 407978 407979 407980 407981 407984 407985 407986 407987 407990 407991 407992 407993 407994 407995 407996 407999 408000 408000 408001 408002 408003 408004 408005 408006 408025 408026 408028 408030 408033 408035 408036 408038 408039 408040 408041 408042 408043 408045 408046 408047 408049 408052 408054 408057 408058 408059 408060 408061 408062 408063 408066 408067 408068 408069 408070 408071 408072 408073 408074 Page Ref. No. GAS8 GBAT1R GBAT1 GRTC3 GCSP1 GCSP2 GRTC1 GRTC2 GI2FAD GI2WAD GI3FB GI3WB GI3FC GI3WC GI3FDT GI3WDT GCSP1R GCSP2R GCPS1 GCPS2 GCPS1R GCPS2R G16H4ED G16H6ED G20H4ED G20H6ED G40M4ED G40M6ED G64M4ED G64M6ED GBCASR GBRONR GBCAS GBRON GCRONR GCRON GBPRO GBPROR GCPRO GCPROR GRONCS GRON GCAS GPRO GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GTUTK20 Cat. No. A.17 A.20 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.20 A.20 A.17 A.17 A.20 A.20 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.21 A.21 A.18 A.18 A.21 A.18 A.18 A.21 A.18 A.21 A.28 A.21 A.21 A.21 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNCT GDPRF GDPRW GFA4 GSFDTR2 GMCNR GMCN GCNTW G54DR GLHD GPBD GREPM GRHD GRHN GLB1 GTUS GUNI GLB3 GSFDTR1 GSDWTR GJP G16H4RVI G20H4RVIn G16H4FFI G20H4FFI G16H6FFI G20H6FFI G32M4FFI G40M4FFI G32M6FFI G40M6FFI G32M4RVI G32M6RVI G40M4RVI G64L4RVI G40M6RVI A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.23 A.23 A.28 A.28 A.21 A.18 A.23 A.23 A.23 A.23 A.23 A.23 A.28 A.23 A.22 A.28 A.23 A.28 A.28 A.23 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 408075 408082 408083 408085 408097 408098 408100 408102 408103 408104 408106 408109 408117 408120 408131 408144 408145 408148 408162 408169 408172 408186 408187 408188 408189 408193 408200 408202 408203 408205 408210 408212 408213 408215 408222 408224 408225 408227 408234 408236 408237 408239 408245 408247 408249 408251 408254 408255 408257 408259 408261 408263 408267 408268 408281 408283 408292 408293 408294 408295 408300 408301 408302 408303 408304 408305 408322 408331 408332 408333 408334 408350 408351 408352 408353 408354 408355 408356 408357 408358 408359 408360 408361 408362 408363 408364 408365 408366 408367 408368 408369 408400 408401 408402 408403 Cat. No. G64L6RVI G16H6RVI G20H6RVIn GFMTG G13HCLS G20HARC G16HCLS G20HCHT G20HCLS G20NARC G20MCLS G25MCLS G32MCLS G40MCLS G40MCHT G64LCHT G50LCLS G64LCLS G25MNRC G40MARC G40NARC G32LNRC G40LNRC G50LNRC G64LNRC G64LARC GG16H2FM GG16H2UM GG16H5FM GG16H5UM GG20H2FM GG20H2UM GG20H5FM GG20H5UM GG20M2FM GG20M2UM GG20M5FM GG20M5UM GG25M2FM GG25M2UM GG25M5FM GG25M5UM GG32M2FM GG32M2UM GG32M5FM GG32M5UM GH32M2VR GH32M5VR GG40M2FM GG40M2UM GG40M5FM GG40M5UM GH40M2VR GH40M5VR GG64L2UM GG64L5UM GH32M2VM GH32M5VM GH40M2VM GH40M5VM G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G25MNCT G32LNCT G40LNCT G50LNCT G64LNCT GW04M4 GW04M6 GW07M4 GW07M6 GW08M4 GW08M6 GW10M4 GW10M6 GW13M4 GW13M6 GW16M4 GW16M6 GW20M4 GW20M6 GW25M4 GW25M6 GW32M4 GW32M6 GW40M4 GW40M6 GW04M1 GW04M3 GW07M1 GW07M3 Page Ref. No. Cat. No. Page A.6 A.6 A.6 A.6 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.24 A.28 A.28 A.24 A.24 A.24 A.24 A.28 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.25 A.25 A.11 A.11 A.11 A.11 A.25 A.25 A.11 A.11 A.11 A.11 A.11 A.11 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.10 A.10 A.10 A.10 408404 408405 408406 408407 408408 408409 408410 408411 408412 408413 408414 408415 408416 408417 408418 408419 408789 408790 408791 408792 408793 408796 408798 408800 408801 408802 408803 408805 408806 408807 408808 408809 408811 408813 408815 408816 408817 408818 408819 408821 408823 408825 408826 408827 408828 408829 408830 408831 408832 408833 408834 408835 408836 408837 408838 408839 408840 408841 408842 408843 408844 408845 408846 408847 408848 408849 408850 408851 408852 408853 408854 408855 408856 408860 408863 408865 GW08M1 GW08M3 GW10M1 GW10M3 GW13M1 GW13M3 GW16M1 GW16M3 GW20M1 GW20M3 GW25M1 GW25M3 GW32M1 GW32M3 GW40M1 GW40M3 GAPU GMPU1 GMPU2 GMPU3 GMPU4 G3G00KA-SR GTG00K1-SR GTG00K1-SF GTG00K2-SF GTG00K2-SR GTG00K9-SF GTG00K3-SF GTG00K4-SF GTG00K3-2SF GTG00K4-2SF GTG00K4-2SR GTG00K9-SR GTG00K9-4SF GTG00K3-4SF GTG00K4-4SF GTG00K3T6SF GTG00K4T6SF GTG00K4T6SR GTG00K9-4SR GTG00N9-5SF GTG00N5-5SF GTG00N6-5SF GTG00N7-5SF GTG00N8-5SF GTG00N5T5SF GTG00N6T5SF GTG00N7T5SF GTG00N8T5SF GTG00N5-8SF GTG00N6-8SF GTG00N7-8SF GTG00N8-8SF GTG00N5T8SF GTG00N6T8SF GTG00N7T8SF GTG00N8T8SF GTG00N5-9SF GTG00N6-9SF GTG00N7-9SF GTG00N8-9SF GTG00N5T9SF GTG00N6T9SF GTG00N7T9SF GTG00N8T9SF GTG00N5T8SR GTG00N6T8SR GTG00N7T8SR GTG00N8T8SR GTG00N5T9SR GTG00N6T9SR GTG00N7T9SR GTG00N8T9SR GTPUNI GTG00N9-8SF GTG00N9-9SF A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.22 A.22 A.22 A.22 A.22 A.27 A.26 A.12 A.12 A.26 A.12 A.12 A.12 A.12 A.12 A.26 A.26 A.13 A.13 A.13 A.13 A.13 A.26 A.26 A.14 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.12 A.14 A.14 By reference number 407732 407733 407734 407735 407736 407737 407738 407739 407740 407741 407742 407743 407744 407753 407754 407770 407771 407772 407773 407774 407775 407776 407777 407778 407779 407780 407781 407782 407783 407784 407785 407795 407796 407797 407798 407799 407800 407801 407802 407803 407804 407805 407806 407807 407808 407809 407810 407816 407817 407818 407819 407820 407821 407822 407823 407824 407825 407835 407836 407837 407838 407839 407840 407841 407842 407843 407844 407849 407850 407851 407852 407853 407854 407860 407861 407862 407863 407864 407865 407866 407867 407868 407869 407870 407871 407876 407877 407878 407879 407880 407881 407882 407883 407886 407887 Intro A B C D E F X X.2 EntelliGuard™ Numerical index Cat. No. Intro A B C D E F X X.3 G… G04HNCT G04HNRC G07HNCT G07HNRC G08HNCT G08HNRC G10HNCT G10HNRC G13HCLS G13HNCT G13HNRC G16H4ED G16H4FFI G16H4RVI G16H6ED G16H6FFI G16H6RVI G16HCLS G16HNCT G16HNRC G20H2SSL G20H4ED G20H4FFI G20H4RVIn G20H5SSL G20H6ED G20H6FFI G20H6RVIn G20HARC G20HCHT G20HCLS G20HNCT G20HNRC G20MCLS G20NARC G25MCLS G25MNCT G25MNRC G32LNCT G32LNRC G32M4FFI G32M4RVI G32M6FFI G32M6RVI G32MCLS G3G00KA-SR G40LNCT G40LNRC G40M2SSL G40M4ED G40M4FFI G40M4RVI G40M5SSL G40M6ED G40M6FFI G40M6RVI G40MARC G40MCHT G40MCLS G40NARC G50LCLS G50LNCT G50LNRC G54DR G64L2SSL G64L4RVI G64L5SSL G64L6RVI G64LARC G64LCHT G64LCLS G64LNCT G64LNRC G64M4ED G64M6ED GA… GAPU GAS3R GAS5 GAS5R GAS6 GAS6R GAS8 GAS8R GB... GBAT1 GBAT1R GBCAS GBCASR GBPRO GBPROR GBRON GBRONR GC... GCAS Ref. No. Page 408300 408000 408301 408001 408302 408002 408303 408003 408097 408304 408004 407930 408060 408058 407931 408062 408082 408100 408305 408005 407606 407932 408061 408059 407607 407933 408063 408083 408098 408102 408103 408006 408006 408106 408104 408109 408322 408162 408331 408186 408066 408070 408068 408071 408117 408796 408332 408187 407636 407934 408067 408072 407637 407935 408069 408074 408169 408131 408120 408172 408145 408333 408188 408038 407679 408073 407680 408075 408193 408144 408148 408334 408189 407936 407937 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.28 A.24 A.24 A.22 A.6 A.6 A.22 A.6 A.6 A.28 A.24 A.24 A.28 A.22 A.6 A.6 A.28 A.22 A.6 A.6 A.28 A.28 A.28 A.24 A.24 A.28 A.28 A.28 A.24 A.24 A.24 A.24 A.6 A.6 A.6 A.6 A.28 A.27 A.24 A.24 A.28 A.22 A.6 A.6 A.28 A.22 A.6 A.6 A.28 A.28 A.28 A.28 A.28 A.24 A.24 A.23 A.28 A.6 A.28 A.6 A.28 A.28 A.28 A.24 A.24 A.22 A.22 408789 407880 407886 407881 407887 407882 407888 407883 A.22 A.20 A.17 A.20 A.17 A.20 A.17 A.20 407891 407889 407970 407967 407978 407979 407971 407968 A.17 A.20 A.18 A.21 A.18 A.21 A.18 A.21 407986 A.21 By catalogue number Cat. No. GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GCCC024D GCCC024DR GCCC048 GCCC048R GCCC060D GCCC060DR GCCC120 GCCC120R GCCC240 GCCC240R GCCC277 GCCC277R GCCC400A GCCC400AR GCCC440A GCCC440AR GCCN024D GCCN024DR GCCN048 GCCN048R GCCN060D GCCN060DR GCCN120 GCCN120R GCCN240 GCCN240R GCCN277 GCCN277R GCCN400A GCCN400AR GCCN440A GCCN440AR GCNTW GCPRO GCPROR GCPS1 GCPS1R GCPS2 GCPS2R GCRON GCRONR GCSP1 GCSP1R GCSP2 GCSP2R GD... GDPRF GDPRW GF... GFA4 GFMTG GG... GG04E1 GG04E3 GG04E4 GG04E6 GG04H1 GG04H3 GG04H4 GG04H6 GG04M1 GG04M3 GG04M4 GG04M6 GG04N1 GG04N3 GG04N4 GG04N6 GG04S1 GG04S3 GG04S4 GG04S6 GG07E1 GG07E3 GG07E4 GG07E6 GG07H1 GG07H3 GG07H4 GG07H6 GG07M1 GG07M3 GG07M4 GG07M6 GG07N1 GG07N3 GG07N4 GG07N6 GG07S1 Ref. No. Page 407990 407991 407992 407993 407994 407995 407996 407836 407835 407838 407837 407840 407839 407842 407841 407844 407843 407849 407850 407852 407851 407853 407854 407861 407860 407863 407862 407865 407864 407867 407866 407869 407868 407870 407871 407877 407876 407878 407879 408036 407980 407981 407922 407924 407923 407925 407976 407974 407895 407915 407896 407916 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.23 A.18 A.21 A.17 A.20 A.17 A.20 A.18 A.21 A.17 A.20 A.17 A.20 408025 408026 A.23 A.23 408028 408085 A.28 A.6 407001 407002 407003 407004 407005 407006 407007 407008 407009 407010 407011 407012 407013 407014 407015 407016 407017 407018 407019 407020 407030 407031 407032 407033 407034 407035 407036 407037 407038 407039 407040 407041 407042 407043 407044 407045 407046 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 Cat. No. GG07S3 GG07S4 GG07S6 GG08E1 GG08E3 GG08E4 GG08E6 GG08H1 GG08H3 GG08H4 GG08H6 GG08M1 GG08M3 GG08M4 GG08M6 GG08N1 GG08N3 GG08N4 GG08N6 GG08S1 GG08S3 GG08S4 GG08S6 GG10E GG10E1 GG10E3 GG10E6 GG10H1 GG10H3 GG10H4 GG10H6 GG10M1 GG10M3 GG10M4 GG10M6 GG10N1 GG10N3 GG10N4 GG10N6 GG10S1 GG10S3 GG10S4 GG10S6 GG13E1 GG13E3 GG13E4 GG13E6 GG13H1 GG13H3 GG13H4 GG13H6 GG13M1 GG13M3 GG13M4 GG13M6 GG13N1 GG13N3 GG13N4 GG13N6 GG13S1 GG13S3 GG13S4 GG13S6 GG16E1 GG16E3 GG16E4 GG16E6 GG16H1 GG16H2FM GG16H2FR GG16H2UM GG16H2UR GG16H3 GG16H4 GG16H5FM GG16H5FR GG16H5UM GG16H5UR GG16H6 GG16M1 GG16M3 GG16M4 GG16M6 GG16N1 GG16N3 GG16N4 GG16N6 GG16S1 GG16S2FM GG16S2FR GG16S2UM GG16S2UR GG16S3 GG16S4 GG16S5FM GG16S5FR Ref. No. 407047 407048 407049 407060 407061 407062 407063 407064 407065 407066 407067 407068 407069 407070 407071 407072 407073 407074 407075 407076 407077 407078 407079 407092 407090 407091 407093 407094 407095 407096 407097 407098 407099 407100 407101 407102 407103 407104 407105 407106 407107 407108 407109 407120 407121 407122 407123 407124 407125 407126 407127 407128 407129 407130 407131 407132 407133 407134 407135 407136 407137 407138 407139 407150 407151 407152 407153 407154 408200 407610 408202 407612 407155 407156 408203 407613 408205 407615 407157 407158 407159 407160 407161 407162 407163 407164 407165 407166 407626 407627 407616 407617 407167 407168 407628 407629 Page A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.4 A.8 A.8 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 Cat. No. GG16S5UM GG16S5UR GG16S6 GG20E1 GG20E3 GG20E4 GG20E6 GG20H1 GG20H2FM GG20H2FR GG20H2UM GG20H2UR GG20H3 GG20H4 GG20H5FM GG20H5FR GG20H5UM GG20H5UR GG20H6 GG20M1 GG20M2FM GG20M2FR GG20M2UM GG20M2UR GG20M3 GG20M4 GG20M5FM GG20M5FR GG20M5UM GG20M5UR GG20M6 GG20N1 GG20N3 GG20N4 GG20N6 GG20S1 GG20S3 GG20S4 GG20S6 GG25H1 GG25H3 GG25H4 GG25H6 GG25M1 GG25M2FM GG25M2FR GG25M2UM GG25M2UR GG25M3 GG25M4 GG25M5FM GG25M5FR GG25M5UM GG25M5UR GG25M6 GG25N1 GG25N3 GG25N4 GG25N6 GG32G1 GG32G3 GG32G4 GG32G6 GG32H1 GG32H3 GG32H4 GG32H6 GG32L1 GG32L3 GG32L4 GG32L6 GG32M1 GG32M2FM GG32M2FR GG32M2UM GG32M2UR GG32M4 GG32M5FM GG32M5FR GG32M5UM GG32M5UR GG32M6 GG32N1 GG32N3 GG32N4 GG32N6 GG40G1 GG40G3 GG40G4 GG40G6 GG40H1 GG40H3 GG40H4 GG40H6 GG40L1 GG40L3 Ref. No. 407618 407619 407169 407190 407191 407192 407193 407194 408210 407620 408212 407622 407195 407196 408213 407623 408215 407625 407197 407198 408222 407630 408224 407632 407199 407200 408225 407633 408227 407635 407201 407202 407203 407204 407205 407206 407207 407208 407209 407230 407231 407232 407233 407234 408234 407640 408236 407642 407235 407236 408237 407643 408239 407645 407237 407238 407239 407240 407241 407250 407251 407252 407253 407242 407273 407244 407245 407248 407249 407254 407255 407260 408245 407650 408247 407652 407262 408249 407654 408251 407656 407263 407264 407265 407266 407267 407268 407269 407270 407271 407278 407279 407280 407281 407282 407283 Page A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 EntelliGuard™ Cat. No. Ref. No. Page 407284 407285 407286 408257 407658 408259 407666 407287 407288 408261 407668 408263 407670 407289 407290 407291 407292 407293 407300 407301 407302 407303 407304 407305 407306 407307 407320 408281 407686 407321 407322 408283 407688 407323 407324 407325 407326 407327 407261 A.4 A.4 A.8 A.11 A.25 A.11 A.25 A.8 A.4 A.11 A.25 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.11 A.25 A.8 A.4 A.11 A.25 A.4 A.8 A.8 A.4 A.4 A.8 407346 407347 407348 408292 408254 407349 408293 408255 407350 407351 407352 407353 407354 408294 408267 407355 408295 408268 407356 407357 A.9 A.9 A.9 A.11 A.25 A.9 A.11 A.25 A.9 A.9 A.9 A.9 A.9 A.11 A.25 A.9 A.11 A.25 A.9 A.9 407900 407901 407902 407904 407906 407903 407905 407907 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 407378 407379 407380 407381 407398 407399 407400 407401 407418 407419 407420 407421 407438 407439 407440 407441 407458 407459 407460 407461 407478 407479 407480 407481 407498 407499 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 Cat. No. GJ20S4 GJ20S6 GJ25N1 GJ25N3 GJ25N4 GJ25N6 GJ32L1 GJ32L3 GJ32L4 GJ32L6 GJ32N1 GJ32N3 GJ32N4 GJ32N6 GJ40L1 GJ40L3 GJ40L4 GJ40L6 GJ40N1 GJ40N3 GJ40N4 GJ40N6 GJ50L1 GJ50L3 GJ50L4 GJ50L6 GJ64L1 GJ64L3 GJ64L4 GJ64L6 GJP GK... GK32N1 GK32N3 GK40N1 GK40N3 GL... GLB1 GLB3 GLHD GM... GM01024D GM01024DR GM01048A GM01048AR GM01048D GM01048DR GM01060D GM01060DR GM01110D GM01110DR GM01120A GM01120AR GM01240A GM01240AR GM01250D GM01250DR GM01400A GM01400AR GM01440A GM01440AR GM02024D GM02024DR GM02048A GM02048AR GM02048D GM02048DR GM02060D GM02060DR GM02110D GM02110DR GM02120A GM02120AR GM02240A GM02240AR GM02250D GM02250DR GM02400A GM02400AR GM02440A GM02440AR GMCN GMCNR GMPU1 GMPU2 GMPU3 GMPU4 GN... GNTK120 GNTK240 GP... GPBD GPRO GR... GREPM GRHD Page Cat. No. 407500 407501 407518 407519 407520 407521 407533 407534 407535 407536 407537 407538 407539 407540 407554 407555 407556 407557 407558 407559 407560 407561 407565 407566 407567 407568 407575 407576 407577 407578 408057 Ref. No. A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.23 407591 407592 407595 407596 A.10 A.10 A.10 A.10 408045 408049 408039 A.23 A.23 A.23 407700 407701 407710 407711 407702 407703 407704 407705 407706 407707 407712 407713 407714 407715 407708 407709 407716 407717 407718 407719 407725 407726 407735 407736 407727 407728 407729 407730 407731 407732 407737 407738 407739 407740 407733 407734 407741 407742 407743 407744 408035 408033 408790 408791 408792 408793 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.18 A.21 A.22 A.22 A.22 A.22 407753 407754 A.17 A.17 408040 407987 A.23 A.21 408041 408042 A.23 A.23 GRHN GRON GRONCS GRTC1 GRTC2 GRTC3 GS... GSDWTR GSFDTR1 GSFDTR2 GSTR024D GSTR024DR GSTR048 GSTR048R GSTR060D GSTR060DR GSTR120 GSTR120R GSTR240 GSTR240R GSTR277 GSTR277R GSTR400A GSTR400AR GSTR440A GSTR440AR GT... GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM250D GTDM277A GTDM400A GTDM440A GTG00K1-SF GTG00K2-SF GTG00K1-SR GTG00K9-SR GTG00K9-4SR GTG00K2-SR GTG00K3-2SF GTG00K3-4SF GTG00K3-SF GTG00K3T6SF GTG00K4-2SF GTG00K4-2SR GTG00K4-4SF GTG00K4-SF GTG00K4T6SF GTG00K4T6SR GTG00K9-4SF GTG00K9-SF GTG00N5-5SF GTG00N5-8SF GTG00N5-9SF GTG00N5T5SF GTG00N5T8SF GTG00N5T8SR GTG00N5T9SF GTG00N5T9SR GTG00N6-5SF GTG00N6-8SF GTG00N6-9SF GTG00N6T5SF GTG00N6T8SF GTG00N6T8SR GTG00N6T9SF GTG00N6T9SR GTG00N7-5SF GTG00N7-8SF GTG00N7-9SF GTG00N7T5SF GTG00N7T8SF GTG00N7T8SR GTG00N7T9SF GTG00N7T9SR GTG00N8-5SF GTG00N8-8SF GTG00N8-9SF GTG00N8T5SF GTG00N8T8SF GTG00N8T8SR GTG00N8T9SF GTG00N8T9SR GTG00N9-5SF GTG00N9-8SF GTG00N9-9SF GTPUNI GTUS GTUTK20 GU... GUNI GUVT024D Ref. No. Page 408043 407985 407984 407897 407899 407894 A.28 A.21 A.28 A.17 A.17 A.17 408054 408052 408030 407770 407771 407772 407773 407774 407775 407776 407777 407778 407779 407780 407781 407782 407783 407784 407785 A.28 A.28 A.28 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 407816 407817 407818 407819 407820 407821 407823 407822 407824 407825 408800 408801 408798 408811 408821 408802 408807 408815 408805 408817 408808 408809 408816 408806 408818 408819 408813 408803 408825 408833 408841 408829 408837 408849 408845 408853 408826 408834 408842 408830 408838 408850 408846 408854 408827 408835 408843 408831 408839 408851 408847 408855 408828 408836 408844 408832 408840 408852 408848 408856 408823 408863 408865 408860 408046 407999 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.12 A.12 A.26 A.26 A.26 A.26 A.12 A.13 A.12 A.13 A.12 A.26 A.13 A.12 A.13 A.26 A.13 A.12 A.14 A.14 A.14 A.14 A.14 A.27 A.14 A.27 A.16 A.16 A.16 A.16 A.16 A.27 A.16 A.27 A.15 A.15 A.15 A.15 A.15 A.27 A.15 A.27 A.16 A.16 A.16 A.16 A.16 A.27 A.16 A.27 A.14 A.14 A.14 A.12 A.22 A.22 408047 407795 A.28 A.17 Cat. No. GUVT024DR GUVT048 GUVT048R GUVT060D GUVT060DR GUVT120 GUVT120R GUVT240 GUVT240R GUVT277 GUVT277R GUVT400A GUVT400AR GUVT440A GUVT440AR GW... GW04M1 GW04M3 GW04M4 GW04M6 GW04N1 GW04N3 GW04N4 GW04N6 GW07M1 GW07M3 GW07M4 GW07M6 GW07N1 GW07N3 GW07N4 GW07N6 GW08M1 GW08M3 GW08M4 GW08M6 GW08N1 GW08N3 GW08N4 GW08N6 GW10M1 GW10M3 GW10M4 GW10M6 GW10N1 GW10N3 GW10N4 GW10N6 GW13M1 GW13M3 GW13M4 GW13M6 GW13N1 GW13N3 GW13N4 GW13N6 GW16M1 GW16M3 GW16M4 GW16M6 GW16N1 GW16N3 GW16N4 GW16N6 GW20M1 GW20M3 GW20M4 GW20M6 GW20N1 GW20N3 GW20N4 GW20N6 GW25M1 GW25M3 GW25M4 GW25M6 GW32M1 GW32M3 GW32M4 GW32M6 GW40M1 GW40M3 GW40M4 GW40M6 GZ... GZ32H1 GZ32H3 GZ40H1 GZ40H3 Ref. No. Page 407796 407797 407798 407799 407800 407801 407802 407803 407804 407805 407806 407807 407808 407809 407810 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 408400 408401 408350 408351 407374 407375 407376 407377 408402 408403 408352 408353 407394 407395 407396 407397 408404 408405 408354 408355 407414 407415 407416 407417 408406 408407 408356 408357 407434 407435 407436 407437 408408 408409 408358 408359 407454 407455 407456 407457 408410 408411 408360 408361 407474 407475 407476 407477 408412 408413 408362 408363 407494 407495 407496 407497 408414 408415 408364 408365 408416 408417 408366 408367 408418 408419 408368 408369 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 407589 407590 407593 407594 A.10 A.10 A.10 A.10 By catalogue number GG40L4 GG40L6 GG40M1 GG40M2FM GG40M2FR GG40M2UM GG40M2UR GG40M3 GG40M4 GG40M5FM GG40M5FR GG40M5UM GG40M5UR GG40M6 GG40N1 GG40N3 GG40N4 GG40N6 GG50L1 GG50L3 GG50L4 GG50L6 GG50M1 GG50M3 GG50M4 GG50M6 GG64L1 GG64L2UM GG64L2UR GG64L3 GG64L4 GG64L5UM GG64L5UR GG64L6 GG64M1 GG64M3 GG64M4 GG64M6 GGM3M3 GH... GH32H1 GH32H3 GH32M1 GH32M2VM GH32M2VR GH32M3 GH32M5VM GH32M5VR GH32N1 GH32N3 GH40H1 GH40H3 GH40M1 GH40M2VM GH40M2VR GH40M3 GH40M5VM GH40M5VR GH40N1 GH40N3 GI... GI2FAD GI2WAD GI3FB GI3FC GI3FDT GI3WB GI3WC GI3WDT GJ... GJ04S1 GJ04S3 GJ04S4 GJ04S6 GJ07S1 GJ07S3 GJ07S4 GJ07S6 GJ08S1 GJ08S3 GJ08S4 GJ08S6 GJ10S1 GJ10S3 GJ10S4 GJ10S6 GJ13S1 GJ13S3 GJ13S4 GJ13S6 GJ16S1 GJ16S3 GJ16S4 GJ16S6 GJ20S1 GJ20S3 Intro A B C D E F X X.4 Numerical index EntelliGuard™ Intro A B C D E F X The policy of GE Energy is one of continuous improvement. The right is reserved to alter the design or any structural details of the products at any time without giving notice. September 2011 GE Industrial Solutions X.5 102003 GE Industrial Solutions GE Energy Industrial Solutions Industrial Solutions (formerly Power Protection), a division of GE Energy, is a first class European supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. @ EntelliGuard™ - Power Circuit Breaker www.ge.com/uk/industrialsolutions www.ge.com/ex/industrialsolutions Ed. 02 GE Energy Industrial Solutions Ltd Houghton Centre Salthouse Road Blackmills Northampton NN4 7EX United Kingdom Customer Service UK Tel. 0800 587 1239 Fax 0800 587 1251 e-mail: order.consind@ge.com General Electric International, Inc 1101, City Tower 2, Sheikh Zayed Road P.O. Box 11549, Dubai United Arab Emirates Tel. +9714 313 1202 GE Energy Industrial Solutions New ™ EntelliGuard Power Circuit Breaker Uncompromising, Fast & Selective Customer Service MEA Tel. +361 447 6046 Fax +361 447 5060 e-mail: mea.export .consind@ge.com GE imagination at work GE imagination at work 680867 Ref. I/3288/G/G 3.0 Ed. 09/11 © Copyright GE Industrial Solutions 2011 Ed. 02