Users Manual Operating and Installation Instructions Buffalo River Black Dimaond Model:ECSL-0601A Electronic Combination Controller b. c. d. e. Note: a. b. If no user code exists, push button “1”, One Beep sounds, which prompts to enter user code. Enter a new six (6) digits code one time. One Beep sounds, which indicates the entry is valid. Re-enter the new six (6) digits code. One Beep sounds, which indicates the codes entered in steps c and d are the same and the adding user process is successful. If Two Beeps sound, the process fails. Repeat steps a to d. Verify the new code at least 3 times before closing the door to make sure the code is correct. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 7. Disable User Code a. Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. Push button “2”, Double Beeps sound, the process of disabling user code is successful. Note: a. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 10 8. Enable User Code a. Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. If the user code exists, push button “1”, Double Beeps sound, the process of enabling user code is successful. Note: a. Verify the code at least 3 times before closing the door to make sure the code is correct . b. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 9. Delete User Code a. Enter the manager code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. Push button “3”, Double Beeps sound, the process of deleting user code is successful. Note: a. Verify the manager code at least 3 times before closing the door to make sure the code is correct. b. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 11 Specifications: Power Supply: DC 9V Power Supply Range: DC 4.5V-12V Standby Current : <15μA Active Current: <20mA Battery Low Voltage: 5.2±0.2V Working Temperature: -25℃~ +60℃ Working Humidity: <95% Storage Temperature: -45℃~ +85℃ Password Length: 6 Digits Mechanical System Life Span: >100,000 Cycles Model: ECSL-0601A User’s Manual Version V1.1120080418(E) 12 ATTENTIONS: ● For indoor use only. Battery Low Voltage: 5.2 ± 0.2V. The display will alert low battery when battery voltage reaches 5.2±0.2V. PLEASE REPLACE THE BATTERY IMMEDIATELY. Battery Replacement Instructions ● 1) In the back of Entry Pad you will see one 9 V alkaline battery. Take the battery out of the battery compartment. Gently pull on the battery until it drops out. 2) Gently remove the connector by unsnapping it from the two terminals on the top of the battery. Never Pull on the Battery Leads 3) Connect a new 9V Alkaline battery to the battery clip. 4) Put the battery and the leads completely back into the battery compartment. ● Mounting and wiring refer to the instruction in this manual 3 FEATURES: 1. Three Codes Capacity a. Master code: Manufacturer default 1-2-3-4-5-6 b. Manager code: No record by default c. User code: No record by default 2. Master Code Function a. Unlock b. Change master code c. Add or delete manager code d. Enable or disable manager code 3. Function of Code for manager code a. Unlock b. Change manager code c. Add or delete user code d. Enable or disable user code 4. Function of Code for User Code a. Unlock b. Change user code 5. Wrong Entry Penalty Entry of four (4) consecutive invalid codes results in 4 a 5-minute delay period. i. The unit beeps at 5 second intervals. ii. During delay period, removing batteries, the entry pad stops counting time; reinstalling batteries, the entry pad continues to count down until 5 minutes delay period finishes. 6. Standby Status The entry pad will turn into a standby status with a long beep sound if there is no operation in 10 seconds after the system is activated. 7. Automatic Re-lock The entry pad will re-lock in 4 seconds after a valid entry is made and the door is open. 8. Low Battery Alert a. Entry pad repeated beeping during an unlocking indicates that the battery is low and needs immediate replacement. b. Manufacturer recommends the use of 9-Volt premier alkaline batteries and an annual maintenance replacement of the batteries. 5 USER OPERATING INSTRUCTIONS 1. ALWAYS PERFORM OPERATIONS WITH THE ENTRY PAD UNLOCK. 2. Before closing the door, make sure all the changes are correct. 3. Do not set the user code to six “0”. 1. Change Master Code, Manager Code or User Code a. Enter “0” six times. One Beep sounds, which indicates the entry is valid and the system is awaiting the code changing. b. Enter the existing six (6) digits code one time. One Beep sounds, which indicates the entry is valid. c. Enter a new six (6) digits code one time. One Beep sounds, which indicates the entry is valid. d. Re-enter the new six (6) digits code. One Beep sounds, which indicates the codes entered in steps c and d are the same and the code changing process is successful. e. If Two Beeps sound, the changing process fails. The existing code is still valid. Repeat steps a to d. 6 Note: a. Verify the new code at least 3 times before closing the door to make sure the code is correct. b. The process for changing the manager code or user code is the same. c. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 2. Add Manager Code a. Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. If no manager code exists, push button “1”, One Beeps sound, which prompts to enter manager code. c. Enter a new six (6) digits code one time. One Beep sounds, which indicates the entry is valid. d. Re-enter the new six (6) digits code. One Beep sounds, which indicates the codes entered in steps c and d are the same and the process is successful. e. If Two Beeps sound, the process fails. Repeat steps a to d. 7 Note: a. b. Verify the new code at least 3 times before closing the door to make sure the code is correct. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 3. Disable Manager Code a. Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. Push button “2”, Double Beeps sound, the process of disabling manager code is successful. Note: a. Verify the master code at least 3 times before closing the door to make sure the code is correct. b. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 4. Enable Manager Code a. Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. If the manager code exists, push button “1”, 8 Note: a. b. Double Beeps sound, the process of enabling manager code is successful. Verify the manager code at least 3 times before closing the door to make sure the code is correct. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 5. Delete Manager Code a. Enter the master code and Hold Down Last Digit of Code until One Beep and then Double Beeps sound. b. Push button “3”, Double Beeps sound, the process of deleting manager code is successful. Note:. a. Verify the master code at least 3 times before closing the door to make sure the code is correct. b. Operations between adjacent steps need be finished in 10 seconds. Otherwise, the system sets back to standby status. 6. Add User Code a. Enter the manager code and Hold Down Last Digit of Code until One beep and then Double Beeps sound. 9