Contents
7 - TeSys control relays
TeSys K control relays
b For a.c. or d.c. control circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/4
b For d.c. control circuit (low consumption) . . . . . . . . . . . . . . . . . . . . . . . . . page 7/5
1
b Instantaneous and time delay auxiliary contact blocks . . . . . . . . . . . . . . page 7/6
b Mounting and marking accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/7
TeSys SK mini-control relays
b Mini-control relays CA2 SK and CA3 SK . . . . . . . . . . . . . . . . . . . . . . . . page 7/12
2
b Mini-control relay with alternating contacts CA2 SKE . . . . . . . . . . . . . . . page 7/12
b Instantaneous auxiliary contacts and coil suppressor modules . . . . . . . page 7/13
TeSys D control relays and add-on blocks
b Control circuit: a.c., d.c. or low consumption
7
. . . . . . . . . . . . . . . . . . . . page 7/21
3
b Add-on blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/22
7
b Accessories and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/23
4
5
6
7
8
9
10
7/1
Characteristics
TeSys control relays
TeSys K control relays
1
Conforming to standards
3URGXFWFHUWL¿FDWLRQV
Operating positions
IEC 60947, NF C 63-140, VDE 0660, BS 5424
UL, CSA
Vertical axis
Horizontal axis
Without derating
Without derating
2
3
4
5
Connection
Screw clamp connections Solid cable
Flexible cable without cable end
Flexible cable with cable end
Spring terminals
Solid cable
Flexible cable without cable end
Faston connectors
Clip
With locating device between
Solder pins forr
printed circuit board
power and control circuits
Tightening torque
Philips head n° 2 and Ø 6
Terminal referencing
Conforming to standards
EN 50005 and EN 50011
Protective treatment
Conf. to IEC 60068 (DIN 50016)
Degree of protection
Conforming to VDE 0106
Ambient air temperature
around the device
Maximum operating altitude
Vibration resistance
5...300 Hz
Flame resistance
6
Shock resistance
(1/2 sine wave, 11 ms)
Safety separation of circuits
Storage
Operation
Without derating
Control relay open
Control relay closed
Conforming to UL 94
Conforming to NF F 16-101
and 16-102
Control relay open
Control relay closed
Conforming to VDE 0106
and IEC 60536
mm2
mm2
mm2
mm2
mm2
mm
N.m
°C
°C
m
Min.
1 x 1.5
1 x 0.75
1 x 0.34
1 x 0.75
1 x 0.75
2 x 2.8 or 1 x 6.35
4 mm x 35 microns
Max.
2x4
2x4
1 x 1.5 + 1 x 2.5
1 x 1.5
1 x 1.5
Possible positions for
CA2 K only, with derating,
please consult your
5HJLRQDO6DOHV2I¿FH
Max. to IEC 60947
1 x 4 + 1 x 2.5
2 x 2.5
1 x 1.5 + 1 x 2.5
2 x 1.5
2 x 1.5
0.8…1.3
Up to 8 contacts
“TC” (Klimafest, Climateproof)
3URWHFWLRQDJDLQVWGLUHFW¿QJHUFRQWDFW
(devices with screw clamp terminals or pins for printed circuit board)
- 50...+ 80
- 25...+ 50
2000
2 gn
4 gn
Self-extinguishing material V1
Conforming to requirement 2
10 gn
15 gn
SELV (Safety Extra Low Voltage), up to 400 V
Control circuit characteristics
7
8
9
Control relay type
Rated control circuit voltage (Uc)
Control voltage limits
For operation
(y 50 °C) single voltage coil
For drop-out
Mechanical durability at Uc
50/60 Hz coil
In millions of operating cycles
Standard c coil
Wide range,
low consumption c coil
Maximum operating rate
In operating cycles per hour
Average consumption
Inrush
at 20 °C and at Uc
Sealed
Heat dissipation
Operating time
Between coil energisation and
at 20 °C and at Uc
opening of the N/C contacts
closing of the N/O contacts
Between coil de-energisation and
opening of the N/O contacts
closing of the N/C contacts
Maximum immunity to microbreaks
CA2 K
a 12...690
0.8...1.15 Uc
y 0.2 Uc
10
–
–
CA3 K
c 12...250
0.8...1.15 Uc
y 0.1 Uc
–
20
–
CA4 K
c 12...120
0.7...1.3 Uc
y 0.1 Uc
–
–
30
W
10 000
30 VA
4.5 VA
1.3
10 000
3W
3W
3
6000
1.8 W
1.8 W
1.8
ms
ms
5...15
10...20
25...35
30...40
25...35
30...40
ms
ms
ms
10...20
15...25
2
10
15
2
10...20
15...25
2
V
10
References :
pages 7/4 and 7/5
7/2
Dimensions :
page 7/8
Schemes :
page 7/9
Characteristics (continued)
TeSys control relays
TeSys K control relays
Contact characteristics of control relays and instantaneous contact blocks
Number of auxiliary contacts
On CAp K
On LA1 K
Rated operational voltage (Ue) Up to
Rated insulation voltage (Ui) Conforming to BS 5424
Conforming to IEC 60947
Conforming to VDE 0110 group C
Conforming to CSA C 22-2 n° 14
Conventional thermal current For ambient temperature y50 °C
(Ith)
Frequency of the operational current
Minimum switching capacity U min (DIN 19 240)
I min
Short-circuit protection
Conforming to IEC 60947
and VDE 0660, gG fuse
Rated making capacity
Conforming to IEC 60947
I rms
Short-time rating
Permissible for
1s
500 ms
100 ms
Insulation resistance
Non-overlap distance
CAp K and LA1 K: linked
contacts conforming to INRS,
%,$DQG&1$VSHFL¿FDWLRQV
V
V
V
V
V
A
4
2 or 4 for CA2 K and CA3 K, 2 for CA4 K
690
690
690
750
600
10
Hz
V
mA
A
Up to 400
17
5
10
A
110
A
A
A
M:
mm
80
90
110
> 10
0.5 (see schemes page 7/9)
1
2
3
4
Operational power of contacts conforming to IEC 60947
a.c. supply, category AC-15
d.c. supply, category DC-13
Electrical durability (valid for up to 3600
operating cycles/hour) on an inductive load
such as the coil of an electromagnet:
making current (cos M 0.7) = 10 times the
power broken (cos M 0.4)
24
110/
127
48
96
240
17
34
86
7
14
36
1000 2050 5000
1 million operating cycles
3 million operating cycles
10 million operating cycles
Occasional making capacity
VA
VA
VA
VA
1 Breaking limit of contacts valid for:
b maximum of 50 operating cycles at 10 s intervals
(power broken = making current x cos M 0.7).
16 000
2
b
b
b
Electrical durability of contacts for:
1 million operating cycles (2a)
3 million operating cycles (2b)
10 million operating cycles (2c).
3 Breaking limit of contacts valid for:
b maximum of 20 operating cycles at 10 s intervals with
current passing for 0.5 s per operating cycle.
48
Power broken in VA
10 000
8000
6000
5000
4000
3000
2000
4
1000
800
600
500
400
300
40
2b
110
220 440 600
W
W
W
W
120
55
15
720
80
38
11
600
60
30
9
400
52
28
8
300
200
200
100
80
60
50
40
30
20
50
2c
20
48
48
250
100
2a
24
24
1000
140
100
80
60
V
51
26
7
230
50
25
6
200
5
6
Power broken in W
1
200
4 Thermal limit
220/ 380/ 440 600/
230 400
690
440 800 880 1200
158 288 317 500
66
120 132 200
10 000 14 000 13 000 9000
Time constant
in ms
V
Electrical durability (valid for up to
1200 operating cycles/hour) on an
inductive load such as the coil of an
electromagnet, without economy
resistor, the time constant increasing
with the load.
110
120
220 380 500
440 690 V
4
700
500
7
3
300
2a
2c
10
8
6
12
8
2b
24
48
110
220 440 600 V
9
10
References :
page 7/6
Dimensions :
page 7/8
Schemes :
page 7/9
7/3
References
TeSys control relays
TeSys K control relays
For a.c. or d.c. control circuit
Control relays for a.c. control circuit
816892
1
b Mounting on 35 mm 7UDLORU‘VFUHZ¿[LQJ
b Screws in the open “ready-to-tighten” position.
Control circuit
Consumption
Basic reference,
to be completed by adding
the voltage code (1)
Weight
kg
2
Screw clamp connections
CA2 KN40pp
pp
4.5 VA
4
3
2
–
1
2
CA2 KN40pp
CA2 KN31pp
CA2 KN22pp
0.180
0.180
0.180
4
3
2
–
1
2
CA2 KN403pp
CA2 KN313pp
CA2 KN223pp
0.180
0.180
0.180
4
3
2
–
1
2
CA2 KN407pp
CA2 KN317pp
CA2 KN227pp
0.180
0.180
0.180
4
3
2
–
1
2
CA2 KN405pp
CA2 KN315pp
CA2 KN225pp
0.210
0.210
0.210
4
3
2
–
1
2
CA3 KN40pp
CA3 KN31pp
CA3 KN22pp
0.225
0.225
0.225
4
3
2
–
1
2
CA3 KN403pp
CA3 KN313pp
CA3 KN223pp
0.225
0.225
0.225
4
3
2
–
1
2
CA3 KN407pp
CA3 KN317pp
CA3 KN227pp
0.225
0.225
0.225
4
3
2
–
1
2
CA3 KN405pp
CA3 KN315pp
CA3 KN225pp
0.255
0.255
0.255
Spring terminal connections
816891
3
Auxiliary
contacts
4.5 VA
Faston connectors, 1 x 6.35 or 2 x 2.8
4.5 VA
4
CA2 KN403pp
pp
Solder pins for printed circuit boards
4.5 VA
Control relays for d.c. control circuit
5
b Mounting on 35 mm 7UDLORU‘VFUHZ¿[LQJ
b Screws in the open “ready-to-tighten” position.
Screw clamp connections
3W
6
Spring terminal connections
3W
CA3 KN407pp
pp
7
Faston connectors, 1 x 6.35 or 2 x 2.8
3W
Solder pins for printed circuit boards
3W
8
6WDQGDUG FRQWURO FLUFXLW YROWDJHV IRU RWKHU YROWDJHV SOHDVH FRQVXOW \RXU 5HJLRQDO 6DOHV 2I¿FH
Control relays CA2 K (0.8...1.15 Uc) (0.85...1.1 Uc)
Volts a 12
20
24(2) 36
42
48
110 115 127 220/ 230 230/ 380/ 400 400/ 440 500
50/60 Hz
230
240 400
415
Code
J7
Z7 B7
C7 D7 E7 F7 FE7 FC7 M7
P7
U7
Q7
V7
N7
R7
S7
Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72
Control relays CA3 K (0.8...1.15 Uc)
Volts c 12
20
24(2) 36
48
60
72
100 110 125 200 220 230 240 250
Code
JD ZD BD
CD ED ND SD KD FD GD
LD
MD MPD MUD UD
Coil with integral suppression device available: add 3 to the code required. Example: JD3.
(2) When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil ((a code Z7,
c code ZD) so as to compensate for the incurred voltage drop.
9
10
Characteristics :
pages 7/2 and 7/3
7/4
Dimensions :
page 7/8
Schemes :
page 7/9
660/
690
Y7
References
TeSys control relays
TeSys K control relays
For d.c. control circuit
Low consumption control relays (d.c. control circuit)
b Mounting on 35 mm 7UDLORU‘VFUHZ¿[LQJ
b Screws in the open “ready-to-tighten” position.
816895
Control circuit
Consumption
1
Auxiliary
contacts
Basic reference,
to be completed
by adding the
voltage code (1)
Weight
kg
Screw clamp connections
1.8 W
CA4 KN40ppp
KN40ppp
4
3
2
–
1
2
CA4 KN40pp
CA4 KN31pp
CA4 KN22pp
0.235
0.235
0.235
4
3
2
–
1
2
CA4 KN403pp
CA4 KN313pp
CA4 KN223pp
0.235
0.235
0.235
4
3
2
–
1
2
CA4 KN407pp
CA4 KN317pp
CA4 KN227pp
0.235
0.235
0.235
4
3
2
–
1
2
CA4 KN405pp
CA4 KN315pp
CA4 KN225pp
0.265
0.265
0.265
2
Spring terminal connections
1.8 W
3
Faston connectors, 1 x 6.35 or 2 x 2.8
1.8 W
4
Solder pins for printed circuit boards
1.8 W
6WDQGDUG FRQWURO FLUFXLW YROWDJHV IRU RWKHU YROWDJHV SOHDVH FRQVXOW \RXU 5HJLRQDO 6DOHV 2I¿FH
Control relays CA4 K (Wide range coil: 0.7...1.3 Uc)
Volts c
12
20
24
48
72
110
120
Code
JW3
ZW3
BW3
EW3
SW3
FW3
GW3
5
6
7
8
9
10
Characteristics :
pages 7/2 and 7/3
Dimensions :
page 7/8
Schemes :
page 7/9
7/5
References
TeSys control relays
TeSys K control relays
Instantaneous and time delay auxiliary contact blocks
Instantaneous auxiliary contact blocks
Clip-on front mounting, 1 per control relay
816899
1
Connection
LA1 KN20
Composition
Reference
Screw clamp terminals
2
–
1
4
3
2
1
–
–
2
1
–
1
2
3
4
LA1 KN20
LA1 KN02
LA1 KN11
LA1 KN40 (1)
LA1 KN31 (1)
LA1 KN22 (1)
LA1 KN13 (1)
LA1 KN04 (1)
kg
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
Spring terminals
2
–
1
4
3
2
1
–
–
2
1
–
1
2
3
4
LA1 KN203
LA1 KN023
LA1 KN113
LA1 KN403 (1)
LA1 KN313 (1)
LA1 KN223 (1)
LA1 KN133 (1)
LA1 KN043 (1)
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
Faston connectors
1 x 6.35 or 2 x 2.8
2
–
1
4
3
2
1
–
–
2
1
–
1
2
3
4
LA1 KN207
LA1 KN027
LA1 KN117
LA1 KN407 (1)
LA1 KN317 (1)
LA1 KN227 (1)
LA1 KN137 (1)
LA1 KN047 (1)
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
2
3
4
5
Weight
Electronic time delay contact blocks
b
b
b
b
b
6
Relay output with common point changeover contact, a or c 240 V, 2 A maximum
Control voltage 0.85...1.1 Uc
Maximum switching capacity 250 VA or 150 W
Operating temperature - 10...+ 60 °C
Reset time: 1.5 s during the time delay period 0.5 s after the time delay period
816899
Clip-on front mounting, 1 per control relay
Voltage
Type
7
LA2 KT2p
KT2p
8
Timing
range
Composition
Reference
V
a or c 24...48
On-delay
s
1...30
1
LA2 KT2E
kg
0.040
a 110...240
On-delay
1...30
1
LA2 KT2U
0.040
Other versions
Electronic timers type RE4.
3OHDVHFRQVXOW\RXU5HJLRQDO6DOHV2I¿FH
(1) Block of 4 contacts for use on CA2 K and CA3 K.
K
9
10
Characteristics :
page 7/3
7/6
Weight
Dimensions :
page 7/8
Schemes :
page 7/9
References
TeSys control relays
TeSys K control relays
Mounting and marking accessories
Suppressor modules incorporating LED indicator
Mounting
and connection
Clips onto front of relay
with locating device.
No tools required.
Type
For
voltages
Sold in
lots of
Unit
reference
Varistor (1)
a and c
12...24 V
5
LA4 KE1B
kg
0.010
a and c
32...48 V
5
LA4 KE1E
0.010
a and c
50...129 V
5
LA4 KE1FC
0.010
a and c
130...250 V
5
LA4 KE1UG
0.010
c
12...24 V
5
LA4 KC1B
0.010
c
32...48 V
5
LA4 KC1E
0.010
a
220...250 V
5
LA4 KA1U
0.010
Sold in
lots of
Unit
reference
LA4 Kppp
Diode + Zener diode (2)
RC (3)
Weight
Mounting accessories
Description
Mounting plates
LA9 D973
Application
Weight
On 1 4 rail
Clip-on
1
LA9 D973
kg
0.025
On 2 4 rails
110/120 mm
¿[LQJFHQWUHV
10
DX1 AP25
0.065
Sold in
lots of
Unit
reference
1
2
3
4
5
Marking accessories
Description
Application
Weight
Marker holder
&OLSRQ¿[LQJRQIURQWIDFH
–
100
LA9 D90
kg
0.001
Clip-in markers
4 maximum per relay
Strips of 10
identical
numbers 0 to 9
25
AB1 Rp (4)
0.002
Strips of 10
identical capital
letters A to Z
25
AB1 Gp (4)
0.002
6
7
(1) Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
(2) No overvoltage or oscillating frequency.
Polarised component.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
(3) Protection by limiting the transient voltage to 3 Uc max. and limitation of the oscillating
frequency.
Slight increase in drop-out time (1.2 to 2 times the normal time).
(4) Complete the reference by replacing the dot with the required character.
8
9
10
Dimensions :
page 7/8
7/7
Dimensions,
mounting
TeSys control relays
TeSys K control relays
Control relays
1
CA2 K, CA3 K, CA4 K
On panel
On printed circuit board
LA1 K
A1
= = =
57
=
35
45
=
35
=
53
50
58
2
50
58
=
8,65
A2
45
On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)
58
3
45
57
4
LA9 D973
DX1 AP25
On asymmetrical rail with clip-on mounting plates
On asymmetrical rail with clip-on mounting plates
5
DZ5 ME5
=
35
=
110
21
5
57
120
50
5
45
57
6
57
45
27
Electronic time delay contact blocks
7
LA2 KT
On control relay
27
LA2 KT
58
38
38
8
57
38
Suppressor modules
LA4 K
On control relay
9
25
LA4 K
6
58
22
10
22
Characteristics:
pages 7/2 and 7/3
7/8
References:
pages 7/4 to 7/7
Schemes:
page 7/9
57
Schemes
TeSys control relays
TeSys K control relays
Control relays
With integral suppression device
CA2 K, CA3 K, CA4 K
CA3 K
CA4 K
1
33/NO
43/NO
A1
13/NO
21/NC
33/NO
43/NO
A1
13/NO
21/NC
31/NC
43/NO
34
44
A2
14
22
34
44
A2
14
22
32
44
+A1
23/NO
24
–A2
13/NO
14
2 N/O + 2 N/C
A1
3 N/O + 1 N/C
A2
4 N/O
2
_ A2
+ A1
Instantaneous auxiliary contact blocks LA1 K
53/NO
61/NC
71/NC
83/NO
62
72
84
83/NO
84
54
73/NO
74
83/NO
63/NO
64
73/NO
53/NO
54
74
61/NC
62
84
53/NO
54
61/NC
61/NC
62
62
51/NC
52
2 N/O + 2 N/C
LA1 KN22,
LA1 KN227
53/NO
63/NO
64
3 N/O + 1 N/C
LA1 KN31,
LA1 KN317
54
4 N/O
LA1 KN40,
LA1 KN407
Electronic time delay contact blocks LA2 KT
Suppressor modules
For CA2 K, CA3 K, CA4 K
LA4 KC
4
81/NC
71/NC
3
5
82
72
61/NC
62
52
81/NC
82
71/NC
72
62
61/NC
4 N/C
LA1 KN04, LA1 KN047
54
1 N/O + 3 N/C
LA1 KN13, LA1 KN137
51/NC
1 N/O + 1 N/C
LA1 KN11,
LA1 KN117
53/NO
2 N/C
LA1 KN02,
LA1 KN027
53/NO
For CA2 K, CA3 K
2 N/O
LA1 KN20,
LA1 KN207
54
For CA2 K, CA3 K, CA4 K
LA4 KE
18
16
6
15
A2
A1
1 C/O
LA2 KT2
+
_
7
8
9
10
Characteristics:
pages 7/2 and 7/3
References:
pages 7/4 to 7/7
Dimensions, mounting:
page 7/8
7/9
Characteristics
TeSys control relays
Mini-control relays TeSys CAp SK and CA2 SKE
Environment
1
2
Rated insulation voltage (Ui) Conforming to IEC 60947,
VDE 0110 gr C, BS 5424,
CSA 22-2 n° 14, UL 508
Conforming to standards
3URGXFWFHUWL¿FDWLRQV
Protective treatment
Conforming to IEC 60068
(DIN 50015)
Degree of protection
Conforming to VDE 0106
Ambient air temperature
Storage
around the device
Operation
Maximum operating altitude Without derating
°C
°C
m
Operating position
Vertical axis
Horizontal axis
Without derating
Without derating
V
690
IEC 60947, NF C 63-110, VDE 0660, BS 5424
UL, CSA
“TC” (Klimafest, Climateproof)
3URWHFWLRQDJDLQVWGLUHFW¿QJHUFRQWDFW
- 50…+ 70
- 20…+ 50
2000
3
4
Connection by connectors
Tightening torque
Terminal referencing
5
6
7
Solid cable
Flexible cable without cable end
Flexible cable with cable end
Pozidriv n° 1 head
Conforming to standards
EN 50005 and EN 50011
mm2
mm2
mm2
N.m
Min.
1 x 1.5 or 2 x 1.5
1 x 0.5 or 2 x 0.35
1 x 0.35 or 2 x 0.35
0.8
Up to 4 contacts
Max.
1 x 6 or 2 x 4
1 x 6 or 2 x 2.5
1 x 6 or 2 x 1.5
Control circuit characteristics
Control relay
Rated control circuit voltage (Uc)
Control voltage limits
For operation
(y 50 °C)
For drop-out
Average consumption
Inrush
at 20 °C and at Uc
Sealed
Heat dissipation
Operating time
Between coil energisation and
at 20 °C and at Uc
opening of the N/C contacts
closing of the N/O contacts
Between coil de-energisation and
opening of the N/O contacts
closing of the N/C contacts
Maximum operating rate
In operating cycles per hour
Mechanical durability at Uc 50/60 Hz coil
in millions of operating cycles Standard c coil
W
CA2 SK
a 24…400
0.85…1.1 Uc
u 0.20 Uc
16 VA
4.2 VA
1.4
ms
ms
8…16
7…14
10…18
8…12
ms
ms
6…8
8…10
1200
10
–
4…6
6…8
1200
–
10
V
8
9
10
References :
pages 7/12 and 7/13
7/10
Dimensions :
page 7/14
Schemes :
page 7/15
CA2 SKE
23 VA
4.9 VA
1.5
CA3 SK
c 12…72
0.85…1.1 Uc
u 0.10 Uc
2.2 W
2.2 W
2.2
Characteristics (continued)
TeSys control relays
Mini-control relays TeSys CAp SK and CA2 SKE
Auxiliary contact characteristics of mini-control relays and instantaneous contact blocks
Rated operational voltage
(Ue)
Rated insulation voltage (Ui)
Conforming to IEC 96047,
BS 5424, VDE 0110 group C,
CSA C 22-2 n° 14
Conventional rated
For ambient temperature
thermal current (Ith)
y 55 °C
Frequency of the operational current
Short-circuit protection
Conforming to IEC 60947
and VDE 0660, gl fuse
V
Up to 690
V
690
A
10
Hz
Up to 400
A
10
1
2
Operational power of contacts conforming to IEC 60947
a.c. supply, category AC-15
Electrical durability (valid for up to 3600
operating cycles/hour) on an inductive load
such as the coil of an electromagnet: making
current (cos M 0.7) = 10 times the power
broken (cos M 0.4).
V
1 million operating cycles
3 million operating cycles
10 million operating cycles
Occasional making capacity
24
VA
VA
VA
VA
48
110/
127
48
96
240
17
34
86
7
14
36
1000 2050 5000
220/
230
440
158
66
10000
380/
400
800
288
120
14000
440
880
317
132
13 000
d.c. supply, category DC-13
Electrical durability (valid for up to 1200
operating cycles/hour) on an inductive load
such as the coil of an electromagnet, without
economy resistor, the time constant
increasing with the load.
V
W
W
W
W
24
120
55
15
720
48
80
38
11
600
110
60
30
9
400
220
52
28
8
300
3
440
51
26
7
230
4
5
6
7
8
9
10
References :
pages 7/12 and 7/13
Dimensions :
page 7/14
Schemes :
page 7/15
7/11
References
TeSys control relays
Mini-control relays TeSys CA2 SK and CA3 SK
Mini-control relay TeSys CA2 SKE with alternating contacts
Mini-control relays
533664
1
b Width of mini-control relays 27 mm.
b Mounting on 35 mm 7 rail.
b Connection by connectors.
Control circuit supply
2
CA2 SK20pp
pp
a.c. supply
d.c. supply
Auxiliary contacts
Basic reference,
to be completed
by adding the
voltage code (1)
Weight
2
–
CA2 SK20pp
kg
0.132
1
1
CA2 SK11pp
0.132
2
–
CA3 SK20pp
0.132
1
1
CA3 SK11pp
0.132
3
Mini-control relay with alternating contacts
533665
This mini-control relay with alternating contacts (see function diagram page 7/15) makes it possible to
automatically split the operating time between 2 circuits of a redundant system.
By regularly energising the “safety circuits”, this device makes it possible to ensure that they are operating
correctly.
4
5
b
b
b
b
b
CA2 SKE20pp
pp
Width of mini-control relay 45 mm.
Fixing by Ø 4 screws.
Connection by connectors.
&DQQRWEH¿WWHGZLWKIURQWPRXQWHGDX[LOLDU\FRQWDFWEORFN
&DQQRWEH¿WWHGZLWKFRLOVXSSUHVVRUPRGXOH
Control circuit supply
a.c. supply
6
Auxiliary contacts
Basic reference,
to be completed
by adding the
voltage code (1)
2
CA2 SKE20pp
–
6WDQGDUG FRQWURO FLUFXLW YROWDJHV IRU RWKHU YROWDJHV SOHDVH FRQVXOW \RXU 5HJLRQDO 6DOHV 2I¿FH
Mini-control relays CA2 SK and CA2 SKE
Volts a
24
48
110
120
220
230
240
50/60 Hz
Code
B7
E7
F7
G7
M7
P7
U7
Mini-control relays CA3 SK
Volts c
12
24
36
48
72
Code
JD
BD
CD
ED
SD
7
8
9
10
Characteristics:
pages 7/10 and 7/11
7/12
Dimensions:
page 7/14
Schemes:
page 7/15
Weight
kg
0.175
380
400
Q7
V7
References
TeSys control relays
Mini-control relays TeSys CA2 SK and CA3 SK
Instantaneous auxiliary contacts and
coil suppressor modules
Instantaneous auxiliary contact blocks
533666
Clip-on front mounting
For use on
control relays
CA2 SK20
Maximum number
of blocks
per contactor
Composition
1
2
–
LA1 SK20
kg
0.022
–
2
LA1 SK02
0.022
1
1
LA1 SK11
0.022
LA1 SK11
Reference
Weight
1
2
Suppressor modules
533667
Connection without need for tools by clipping onto right-hand side of contactor
For use on
control relays
CA2 SK and CA3 SK
LA4 SKp
p1p
Type
Varistor
(1)
Diode
(2)
For
voltages
Sold
in
lots of
10
Unit
reference
Weight
LA4 SKE1E
kg
0.003
a and c 110 V…250 V 10
LA4 SKE1U
0.003
c 24 V…250 V
LA4 SKC1U
0.003
a and c 24 V…48 V
10
3
4
(1) Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
(2) No overvoltage or oscillating frequency.
Slight increase in drop-out time (1.1 to 1.5 times the normal time).
5
6
7
8
9
10
Characteristics:
pages 7/10 and 7/11
Dimensions:
page 7/14
Schemes:
page 7/15
7/13
Dimensions, mounting
TeSys control relays
Mini-control relays TeSys CAp SK and CA2 SKE
Dimensions
1
Mini-control relays
CA2 SK and CA3 SK
55,5
27
5
84,5
55,5
56
56
2
LA4 SK
3,5
LA1 SK (1)
3
27
3,5
(1) Only on CA2 SK20.
Mounting
Mini-control relays
CA2 SK and CA3 SK
On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)
4
27
56
55,5
5
Dimensions
CA2 SKE
6
68
58
45
7
4
Mounting
CA2 SKE
8
On panel
On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)
9
34-35
10
Characteristics :
pages 7/10 and 7/11
7/14
45
58
48-50
68
References :
pages 7/12 and 7/13
Schemes :
page 7/15
Schemes
TeSys control relays
Mini-control relays TeSys CAp SK and CA2 SKE
Schemes
13/NO
23/NO
A1
13/NO
21/NO
14
24
A2
14
22
1 N/O + 1 N/C
A1
CA2 SK11, CA3 SK11
2 N/O
A2
CA2 SK20, CA3 SK20
1
2
13/NO
23/NO
A1
14
24
Function diagram
A1
CA2 SKE
2 N/O
A2
CA2 SKE
13
A2
Energised
De-energised
14
3
Close
Open
23
24
Close
Open
4
2 N/O
LA1 SK20
2 N/C
LA1 SK02
1 N/O + 1 N/C
LA1 SK11
33/NO
43/NO
31/NC
41/NC
33/NO
41/NC
34
44
32
42
34
42
Instantaneous auxiliary contacts
5
6
7
8
9
10
Characteristics :
pages 7/10 and 7/11
References :
pages 7/12 and 7/13
Dimensions, mounting :
page 7/14
7/15
Characteristics
7
TeSys control relays
7
TeSys D control relays
Control relay type
1
2
4
CAD c
CAD
low consumption
Environment
Rated insulation voltage (Ui)
Rated impulse withstand
voltage (Uimp)
Separation of
electrical circuits
Conforming to standards
Conforming to IEC 60947-5-1
Overvoltage category III and
degree of pollution 3
Conforming to UL, CSA
V
690
690
690
V
600
600
600
Conforming to IEC 60947
kV
6
6
6
Conforming to IEC 60536
and VDE 0106
Reinforced insulation up to 400 V
IEC 60947-5-1, N-F C 63-140, VDE 0660, BS 4794,
EN 60947-5
UL, CSA
3URGXFWFHUWL¿FDWLRQV
3
CAD a
Protective treatment
Conforming to IEC 60068
“TH”
Degree of protection
Conforming to VDE 0106
)URQWIDFHSURWHFWHGDJDLQVWGLUHFW¿QJHUFRQWDFW,3;
Ambient air temperature
around the device
Storage
Operation, conforming to
IEC 60255 (0.8…1.1 UC)
For operation at Uc
°C
°C
- 60…+ 80
- 5…+ 60
- 60…+ 80
- 5…+ 60
Protection against direct
¿QJHUFRQWDFW
- 60…+ 80
- 5…+ 60
°C
- 40…+ 70
- 40…+ 70
- 40…+ 70
Maximum operating altitude
Without derating
m
3000
3000
3000
Operating positions
Without derating
in the following positions
Shock resistance (1)
half sine wave for 11ms
Control relay open
Control relay closed
10 gn
15 gn
10 gn
15 gn
10 gn
15 gn
Vibration resistance (1)
5…300 Hz
Control relay open
Control relay closed
2 gn
4 gn
2 gn
4 gn
2 gn
4 gn
Screw clamp connections
Flexible
1 conductor
conductor
2 conductors
without cable
end
Flexible
1 conductor
conductor with 2 conductors
cable end
Solid conductor 1 conductor
without cable
2 conductors
end
Tightening torque
mm2
mm2
1…4
1…4
1…4
1…4
1…4
1…4
mm2
mm2
1…4
1…2.5
1…4
1…2.5
1…4
1…2.5
mm2
mm2
1…4
1…4
1…4
1…4
1…4
1…4
N.m
1.7
1.7
1.7
1…2.5
1…2.5
1…2.5
7
8
Spring terminal connections
RUÀH[LEOHRUULJLGFRQGXFWRUV mm2
without cable end
0°
0°
9
°
6
180°
180°
°
90
90
30
°
5
180°
30°
9
(1) In the least favourable direction, without change of contact state, with coil supplied at Uc.
9
10
References :
pages 7/21 to 7/23
7/16
Dimensions :
page 7/24
Schemes :
page 7/25
Characteristics (continued)
7
TeSys control relays
7
TeSys D control relays
Control relay type
CAD a
CAD c
CAD
low consumption
12…690
12…440
c 5…72
0.8…1.1 Uc at 50 Hz
0.85…1.1 Uc at 60 Hz
–
–
–
0.7…1.25 Uc
–
–
0.7…1.25 Uc
0.3…0.6 Uc
0.1…0.25 Uc
0.1…0.25 Uc
Control circuit characteristics
Rated control circuit voltage (Uc)
Control voltage limits
Operation
With coil 50/60 Hz
V
With standard coil,
wide range
Drop-out
Average consumption
at 20 °C and at Uc
Operating time
(at rated control circuit voltage
and at 20 °C)
a 50/60 Hz (at 50 Hz)
VA
Inrush: 70
sealed: 8
–
–
–
–
With standard coil
W
–
Inrush or sealed: 5.4
Inrush or sealed: 2.4
4…19
55 ± 15 %
67 ± 15 %
12…22
63 ± 15 %
77 ± 15 %
4…12
20 ± 20 %
27 ± 20 %
6…17
25 ± 20 %
35 ± 20 %
2
2
2
3
3
3
30
–
–
–
30
30
–
28
40
Between coil energisation
ms
and
- opening of the N/C contacts
- closing of the N/O contacts ms
Between coil de-energisation ms
and
- opening of the N/O contacts
- closing of the N/C contacts ms
Short supply failure
Maximum operating rate
Mechanical durability
In millions of operating cycles
Time constant L/R
Maximum duration without
ms
affecting hold-in of the device
In operating cycles
per second
With coil 50/60 Hz
(at 50 Hz)
With standard coil c
wide range
ms
1
2
3
4
5
6
7
8
9
10
References :
pages 7/21 to 7/23
Dimensions :
page 7/24
Schemes :
page 7/25
7/17
Characteristics (continued)
7
TeSys control relays
7
TeSys D control relays
Characteristics of instantaneous contacts incorporated in the control relay
1
2
3
Number of contacts
5
Rated operational voltage
Up to
(Ue)
Rated insulation voltage (Ui) Conforming to IEC 60947-5-1
Conforming to UL, CSA
Conventional
For ambient temperature d60 °C
thermal current (Ith)
Frequency of the
operational current
Minimum switching capacity U min
I min
Short-circuit protection
Rated making capacity
Short-time rating
Conforming to IEC 60947-5-1
Conforming to
I rms
IEC 60947-5-1
Permissible for
1s
500 ms
100 ms
Insulation resistance
4
Non-overlap time
Tightening torque
Guaranteed between
N/C and N/O contacts
Philips head n° 2 and Ø 6
Non-overlap distance
5
Mechanically linked
contacts
V
690
V
V
690
600
A
10
Hz
25...400
V
mA
17
5
gG fuse: 10 A
a : 140, c : 250
A
A
A
100
120
140
M:
> 10
ms
1.5 (on energisation and on de-energisation)
N.m
1.2
Linked contacts in association with auxiliary contacts LAD N
Conforming to IEC 60947-5-1
The 3 N/O contacts and the 2 N/C contacts of CAD N32 are linked mechanically by one
mobile contact carrier.
6
7
8
9
10
References :
pages 7/21 to 7/23
7/18
Dimensions :
page 7/24
Schemes :
page 7/25
Characteristics (continued)
7
TeSys control relays
7
TeSys D control relays
Rated operational power of contacts (conforming to IEC 60947-5-1)
a.c. supply, categories AC-14 and AC-15
Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive load such
as the coil of an electromagnet:
making current (cos M 0.7) = 10 times the power broken (cos M 0.4).
V
VA
VA
VA
1 million operating cycles
3 million operating cycles
10 million operating cycles
24
60
16
4
48
120
32
8
115
280
80
20
230
560
160
40
400
960
280
70
440
1050
300
80
600
1440
420
100
1
2
Millions of operating cycles
10
8
7
6
5
4
3
3
2
1
0,8
0,7
0,6
0,5
4
0,4
0,3
0,2
0,1
0,1
0,2
0,3
0,4
0,5
0,6 0,8 1
0,7 0,9
2
3
5
4
6
8 10
5
7
9
Current broken in A
d.c. supply, category DC-13
Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive load
such as the coil of an electromagnet, without economy resistor, the time constant
increasing with the power.
V
W
W
W
Millions of operating cycles
1 million operating cycles
3 million operating cycles
10 million operating cycles
10
8
7
6
5
4
24
120
70
25
48
90
50
18
125
75
38
14
250
68
33
12
6
440
61
28
10
7
24 V
48 V
125 V
3
250 V
2
8
1
0,8
0,7
0,6
0,5
440 V
0,4
0,3
9
0,2
0,1
0,1
0,2
0,3
0,4
0,5
0,6 0,8 1
0,7 0,9
2
3
4
6
8 10
5
7
9
Current broken in A
10
References :
pages 7/21 to 7/23
Dimensions :
page 7/24
Schemes :
page 7/25
7/19
aa
1
2
3
4
5
6
7
8
9
See page opposite for mounting possibilities
according to control relay type and rating
10
7/20
References
7
TeSys control relays
7
TeSys D control relays and add-on blocks
Control circuit: a.c., d.c. or low consumption
Control relays for connection by screw clamp terminals
Type
Number of
contacts
Composition
Basic reference, to be
completed by adding the
control voltage code (1)
Weight
1
Standard voltages
a
Instantaneous 5
CAD 50
50pp
pp
c
LC (2)
5
–
CAD 50pp (3)
B7
P7
BD
BL
0.580
3
2
CAD 32pp (3)
B7
P7
BD
BL
0.580
kg
Control relays for connection by spring terminals
Instantaneous 5
5
–
CAD 503pp
B7
P7
BD
BL
0.580
3
2
CAD 323pp
B7
P7
BD
BL
0.580
Instantaneous auxiliary contact blocks for connection by screw clamp terminals
For use in normal operating environments
Number of
contacts
CAD 32pp
32pp
2
4 (4)
Maximum number per relay
Clip-on mounting
front
side
Composition
Reference
1
–
1
–
1
–
1
1
1
2
2
–
–
2
1
4
–
3
2
LAD N11
LAD 8N11 (6)
LAD N20
LAD 8N20 (6)
LAD N02
LAD 8N02 (6)
LAD N22
LAD N13
LAD N40
LAD N04
LAD N31
LAD C22
–
1 on LH side
–
1 on LH side
–
1 on LH side
–
4 (4)
1
–
Including 1 N/O and 1 N/C make before break.
CAD 503
503pp
pp
1
1
–
–
2
2
2
3
–
4
1
2
2
3
Weight
kg
0.030
0.030
0.030
0.030
0.030
0.030
0.050
0.050
0.050
0.050
0.050
0.050
4
5
With dust and damp protected contacts, for use in particularly harsh industrial environments
Number of
contacts
Maximum
number per
relay
Front
mounting
2
1
4 (4)
1
Composition
Reference
Weight
6
protected (5)
2 – –
– 2 –
2 – 2
2 – –
2 – –
kg
–
–
–
2
1
–
–
–
–
1
LA1 DX20
LA1 DX02
LA1 DY20
LA1 DZ40
LA1 DZ31
0.040
0.040
0.040
0.050
0.050
7
CAD 323pp
323pp
Instantaneous auxiliary contact blocks for connection by spring terminals
This type of connection is not possible for contact blocks LAD 8 and blocks with dust and damp protected contacts. For all other
instantaneous auxiliary contact blocks, add the digit 3 to the end of the references selected above.
Example: LAD N11 becomes LAD N113.
6WDQGDUG FRQWURO FLUFXLW YROWDJHV IRU RWKHU YROWDJHV SOHDVH FRQVXOW \RXU 5HJLRQDO 6DOHV 2I¿FH
a.c. supply
Volts a
24
42
48
110
115
220
230
240
380
400
415
440
50/60 Hz
B7
D7
E7
F7
FE7
M7
P7
U7
Q7
V7
N7
R7
d.c. supply FRLOVZLWKLQWHJUDOVXSSUHVVLRQGHYLFH¿WWHGDVVWDQGDUG
Volts c
12
24
36
48
60
72
110
125
220
250
440
U from 0.7 to 1.25 Uc JD
BD
CD
ED
ND
SD
FD
GD
MD
UD
RD
Low consumption FRLOVZLWKLQWHJUDOVXSSUHVVLRQGHYLFH¿WWHGDVVWDQGDUG
Volts c
5
12
20
24
48
110
220
250
Code
AL
JL
ZL
BL
EL
FL
ML
UL
/& ORZ FRQVXPSWLRQ
(3) To order control relays with connection by lugs, add the digit 6 to the end of the selected reference.
Example: CAD50pp becomes CAD506pp.
(4) Blocks with 4 auxiliary contacts cannot be used on low consumption control relays.
3URGXFW ¿WWHG ZLWK HDUWK VFUHHQ FRQWLQXLW\ WHUPLQDOV
(6) These contact blocks cannot be used on low consumption control relays.
Characteristics :
pages 7/16 and 7/17
Dimensions :
page 7/24
Schemes :
page 7/25
7/21
8
9
10
References
7
TeSys control relays
7
TeSys D control relays
Add-on blocks
Time delay auxiliary contact blocks for connection by screw clamp terminals (1)
Number
and type of
contacts
1
1 N/C and 1 N/O
Maximum number
per relay
Front mounting
1
Time delay
Type
On-delay
Off-delay
2
(Sealing cover: see page 5/85)
Reference
Range
0.1…3 s (2)
0.1…30 s
10…180 s
1…30 s (3)
0.1…3 s (2)
0.1…30 s
10…180 s
Weight
kg
LAD T0
LAD T2
LAD T4
LAD S2
LAD R0
LAD R2
LAD R4
0.060
0.060
0.060
0.060
0.060
0.060
0.060
LAD T
Time delay auxiliary contact blocks for connection by spring terminals
Add the digit 3 to the references selected above. Example: LAD T0 becomes LAD T03.
Mechanical latch blocks (4)
3
Unlatching
control
Manual or
electric
Maximum number
per relay
Front mounting
1
Basic reference
to be completed
(5)
LAD 6K10p
Weight
kg
0.070
Suppressor modules
4
These modules clip onto the top of the control relay and the electrical connection is instantly made. Fitting of an input
module is still possible.
LAD 6K10
RC circuits (Resistor-Capacitor)
b Effective protection for circuits highly sensitive to “high frequency” interference.
b Voltage limited to 3 Uc maximum and oscillating frequency limited to 400Hz maximum.
b Slight time delay on drop-out (1.2 to 2 times the normal time).
For
Operational
Reference
mounting on
voltage
CAD a
a 24…48 V
LAD 4RCE
a 110…240 V
LAD 4RCU
5
Weight
kg
0.012
0.012
Varistors (peak limiting)
b Protection provided by limiting the transient voltage value to 2Uc maximum.
b Maximum reduction of transient voltage peaks.
b Slight time delay on drop-out (1.1 to 1.5 times the normal time).
CAD a
a 24…48 V
LAD 4VE
a 50…127 V
LAD 4VG
a 110…250 V
LAD 4VU
6
0.012
0.012
0.012
Freewheel diode
LAD 4pp
7
b No overvoltage or oscillating frequency.
b Increase in drop-out time (6 to 10 times the normal time).
b Polarised component.
CAD c
c 24…250 V
LAD 4DDL
0.012
Bidirectional peak limiting diode
b Protection provided by limiting the transient overvoltage value to 2Uc maximum.
b Maximum reduction of transient voltage peaks.
CAD a
a 24 V
LAD 4TB
a 72 V
LAD 4TS
CAD c
c 24 V
LAD 4TBDL
c 72 V
LAD 4TSDL
c 125 V
LAD 4TGDL
c 250 V
LAD 4TUDL
c 600 V
LAD 4TXDL
8
9
LAD 4DDL or LAD 4TpDL
10
Characteristics :
pages 7/16 and 7/17
7/22
0.012
0.012
0.012
0.012
0.012
0.012
0.012
(1) These contact blocks cannot be used on low consumption control relays.
(2) With extended scale from 0.1 to 0.6 s.
(3) With switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O contact.
(4) Power should not be simultaneously applied or maintained to the mechanical latching block of the CAD N. The duration of
the control signal to the mechanical latching block and the CAD N should be u 100 ms.
6WDQGDUGFRQWUROFLUFXLWYROWDJHVIRURWKHUYROWDJHVSOHDVHFRQVXOW\RXU5HJLRQDO6DOHV2I¿FH
Volts a and c
24
32/36
42/48
60/72
100
110/127 220/240 256/277 380/415
Code
B
C
E
EN
K
F
M
U
Q
(6) CAD ppGFDQGORZFRQVXPSWLRQFRQWUROUHOD\VDUH¿WWHGZLWKDEXLOWLQELGLUHFWLRQDOSHDNOLPLWLQJGLRGHVXSSUHVVRU
as standard. On control relays produced after 15th July 2004, this diode is removable. It can therefore be replaced by
the user (see references LAD 4Tppp above). It can also be replaced by a freewheel diode LAD 4DDL . If a d.c. or
low consumption control replay is used without suppression, the standard suppressor should be replaced with a
blanking plug LAD 9DL.
Illustrations:
page 7/20
Dimensions :
page 7/24
Schemes :
page 7/25
References
7
TeSys control relays
7
TeSys D control relays
Accessories and spare parts
Accessories (to be ordered separately)
Description
For marking
Sheet of 64 blank legends,
self-adhesive, 8 x 33 mm
For
mounting on
Sold in
lots of
Unit reference
CAD, LAD (4 contacts)
10
LAD 21
0.020
LAD 22
0.020
35
LAD 24
0.200
1
XBY 2U
0.100
100
LAD 90
0.001
Sheet of 112 blank legends, LAD (2 contacts),
self-adhesive, 8 x 12 mm
LAD T
LA9 D901
Strips of blank, self-adhesive All products
legends for printing by plotter
(4 sets of 5 strips)
“SIS Label” labelling
Multi-language version:
software for legends LAD 21 English, French, German,
and LAD 22, supplied on
Italian, Spanish
CD-Rom
Legend holder, snap-in,
LC1 D09...38
8 x 18 mm
LC1DT20...40
LADN (4 contacts)
LAD T, LAD R
For protection
Sealing cover
LAD T, LAD R
Safety cover preventing
CAD
access to the moving contact
carrier
Weight
kg
LXD 1
2
3
1
LA9 D901
LAD 9ET1
0.005
0.004
1
Spare parts: coils
LAD 9ET1
1
6SHFL¿FDWLRQV
b Average consumption at 20 °C:
- inrush (cos M = 0.75) 50/60 Hz: 70 VA at 50 Hz,
- sealed (cos M = 0.3) 50/60 Hz: 8 VA at 60 Hz,
b Operating range (T < 60 °C): 0.85 to 1.1 Uc
Control circuit
Average resistance
Inductance of Reference (1)
voltage Uc
at 20 °C ± 10 %
closed circuit 50/60 Hz
V
V
H
12
6.3
0.26
LXD 1J7
21 (2)
5.6
0.24
LXD 1Z7
24
6.19
0.26
LXD 1B7
32
12.3
0.48
LXD 1C7
36
–
–
LXD 1CC7
42
19.15
0.77
LXD 1D7
48
25
1
LXD 1E7
60
–
–
LXD 1EE7
100
–
–
LXD 1K7
110
130
5.5
LXD 1F7
115
–
–
LXD 1FE7
120
159
6.7
LXD 1G7
127
192.5
7.5
LXD 1FC7
200
–
–
LXD 1L7
208
417
16
LXD 1LE7
220/230
539
22
LXD 1M7 (3)
230
595
21
LXD 1P7
230/240
645
25
LXD 1U7 (4)
277
781
30
LXD 1W7
380/400
1580
60
LXD 1Q7
400
1810
64
LXD 1V7
415
1938
74
LXD 1N7
440
2242
79
LXD 1R7
480
2300
85
LXD 1T7
500
2499
–
LXD 1S7
575
3294
–
LXD 1SC7
600
3600
135
LXD 1X7
690
5600
190
LXD 1Y7
(1) The last 2 digits in the reference represent the voltage code.
9ROWDJHIRUVSHFLDOFRLOV¿WWHGLQFRQWUROUHOD\VZLWKVHULDOWLPHUPRGXOHZLWK9VXSSO\
(3) This coil can be used on 240 V at 60 Hz.
(4) This coil can be used on 230/240 V at 50 Hz and on 240 V only at 60 Hz.
4
Weight
kg
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
5
6
7
8
9
10
Characteristics :
pages 7/16 and 7/17
Dimensions :
page 7/24
Schemes :
page 7/25
7/23
Dimensions,
mounting
TeSys control relays
0
TeSys D control relays and add-on blocks
Dimensions
CAD c or LC (low consumption)
b
CAD a
b
1
c
2
3
4
c1
12,5
(LAD8)
45
c
c2
c2
c3
c3
CAD
45
c1
32
50
323
503
b
c
without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
77
84
86
117
99
84
86
117
c2 with LAD 6K10
c3 with LAD T, R, S
with LAD T, R, S and sealing cover
129
137
141
129
137
141
CAD
32
50
323
503
b
c
without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
77
93
95
126
99
93
95
126
c2 with LAD 6K10
c3 with LAD T, R, S
with LAD T, R, S and sealing cover
138
146
150
138
146
150
Mounting
CAD
Panel mounted
Mounted on rail AM1 DP200 or DE200
5
60/70
=
78
=
=
(1)
=
c
c
with cover
35
=
=
6
45
c
CAD a
CAD c or LC
86
95
c
c
7
(1) 2 elongated holes 4.5 x 9
(AM1 DP200) (2)
(AM1 DP200) (2)
(2) With cover
Mounted on plate AM1 P
AF1 EA4
60/70
8
9
c
c
with cover
35
CAD a
CAD c or LC
86
95
10
Characteristics :
pages 7/16 to 7/19
7/24
Illustrations:
page 7/20
References :
pages 7/21 to 7/23
Schemes :
page 7/25
CAD a
CAD c or LC
88
96
97
105
Schemes
TeSys control relays
0
TeSys D control relays and add-on blocks
Instantaneous auxiliary contacts
3 N/O + 2 N/C
CAD 32
A1
13/NO
23/NO
33/NO
43/NO
03/NO
A1
13/NO
21/NC
31/NC
43/NO
03/NO
14
24
34
44
04
A2
14
22
32
44
04
1
A2
5 N/O
CAD 50
2
61/NC
51/NC
3
62
162
(171)
52
161/NC
(172)
151/NC
(182)
152
(181)
163/NC
(174)
LAD N02
154
(183)
LAD 8N20 (1)
2 N/C
LAD 8N02
164
(173)
63/NO
64
53/NO
2 N/O
LAD N20
54
162
(171)
154
(183)
161/NC
(172)
LAD 8N11 (1)
153/NO
(184)
61/NC
62
54
53/NO
1 N/O + 1 N/C
LAD N11
153/NO
(184)
Instantaneous auxiliary contact blocks
7KH¿JXUHVLQEUDFNHWVDUHIRUWKHGHYLFHPRXQWHGRQWKH5+VLGHRIWKHFRQWUROUHOD\
71/NC
83/NO
53/NO
61/NC
71/NC
81/NC
53/NO
63/NO
73/NO
83/NO
51/NC
61/NC
71/NC
81/NC
53/NO
61/NC
73/NO
83/NO
72
84
54
62
72
82
54
64
74
84
52
62
72
82
54
62
74
84
3 N/O + 1 N/C
LAD N31
61/NC
4 N/C
LAD N04
53/NO
4 N/O
LAD N40
62
1 N/O + 3 N/C
LAD N13
54
2 N/O + 2F N/C
LAD N22
2 N/O + 2 N/C including
1 N/O + 1 N/C
make before break
63/NO
51/NC
61/NC
53/NO
63/NO
53/NO
63/NO
73/NO
83/NO
53/NO
61/NC
73/NO
83/NO
52
62
54
64
54
64
74
84
54
62
74
84
87/NO
88
LA1 DZ40
2 N/O protected +
1 N/O + 1 N/C
non protected
LA1 DZ31
64
75/NC
76
LA1 DY20
2 N/O protected +
2 N/O non protected
53/NO
61/NC
LA1 DX02
2 N/O protected (2)
54
53/NO
62
5
With dust and damp protected contacts
2 N/O protected
2 N/C protected
LA1 DX20
54
LAD C22
4
6
3URGXFW¿WWHGZLWKHDUWKVFUHHQFRQWLQXLW\WHUPLQDOV
7
Time delay auxiliary contact blocks
E1
65/NC
66
A1
57/NO
58
LAD 6K10
8
E2
A2
55/NC
67/NO
Off-delay 1 N/O + 1 N/C
LAD R
68
67/NO
68
LAD S
56
55/NC
56
On-delay 1 N/O + 1 N/C
LAD T
Mechanical latch blocks
9
10
Characteristics :
pages 7/16 to 7/19
Illustrations:
page 7/20
References :
pages 7/21 to 7/23
Schemes :
page 7/24
7/25