sirco non-fusible disconnects

advertisement
Non-Fusible Disconnects
SIRCO Series
Overview
Features
Ferraz Shawmut SIRCO disconnect
switches are heavy duty, manually operated, non-fused disconnect switches,
designed using the latest disconnect switch
technology available. SIRCO switches meet
UL98 standards with a product that “makes
and breaks” power circuits on load. These
switches have been tested and approved
for use in the most demanding applications, including “service entrance”. Visible
blade contacts are standard in SIRCO
switches up to 400A. Choose from a wide
array of handles meeting OSHA
padlocking requirements, NEMA configurations, defeater options and NFPA 79
requirements.
Ratings
• Service entrance rated
• Compact footprints
• Front operated switches
• Visible blade contacts up to 400A
• Line side shrouding supplied with switch
• Defeatable pistol handles automatically
re-latch when panel door is closed - no tool
necessary to reset latch
• External or direct operation handles
• 600 VAC, 250 VDC
• 30, 60, 100, 200, 400, 600, and 800 amperes
• Up to 200 kA short circuit rating when
Class CC, J, or L fuses are used externally
Approvals
• All SIRCO switches meet UL 98
requirements
• UL Listed Guide WHTY, File E191605
• CSA C22.2 # 4 Class 4652 04, File 703166
• IEC 947-3 as a load break disconnect
• CE mark
Applications
• Service entrance or main panel
disconnects up to 600 VAC, 800 A
• “Make and Break” power circuit
applications on load
• NFPA 79 Solutions
SIRCO Range: Non-Fusible Disconnect Switches
Ampere Rating
30
Catalog Number: 3 Pole
SCV30 SCV60 SCV100 SCV200 SCV400 SC600 SC800
60
100
200
400
600 800
Components
30 Amp
60 to
400 Amp
1
1
2
4
3
5
6
3
4
5
7
9
8
Components
1 – External Door Handle
2 – Direct Mount Handle Option
3 – NFPA 79 Compliant
Handle Option
4 – Standard Shaft
5 – Auxiliary Contact Block
6 – Auxiliary Contact Holder
7 – Disconnect Switch Body
7
6
8 – Terminal Lugs
9 – Terminal Shroud
Volume 13
e31-64
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects
SIRCO Series Selection Guides
Company
Information
Systems
Overview
Programmable
Controllers
SIRCO Series Front-operated Non-Fusible Disconnects
Switch Body
Part Number
SCV30
SCV60
SCV100
SCV200
SCV400
SC600
SC800
Field I/O
Price Weight lb(kg) Ampere
Rating Hp @ Voltage Interrupt Capacity (kA)*
<--->
3.9(1.79)
30
15 Hp @ 480V
50
<--->
<--->
4.0(1.80)
60
30 Hp @ 480V
200
5.5(2.50)
100
60 Hp @ 480V
200
<--->
7.6(3.40)
200
125 Hp @ 480V
200
<--->
17.2(7.80)
400
250 Hp @ 480V
200
<--->
18.7(8.50)
600
400 Hp @ 480V
200
<--->
19.6(8.90)
800
500 Hp @ 480V
100
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
* When fused separately
Steppers/
Servos
Ferraz Non-Fusible Disconnects Component Selection Guide
Part Number
SD200-5
SD320-5
SG120-5
SG200-10
SG200-5
SG320-10
SG320-5
SG400-10
SH400-15
HADB1
HADB6
HADB8
HDPB
HDPR
HGPB
HGPB4
HGPB4L
HGPBL
HGPR
HGPR4
HGPR4L
HGPRL
HHPB4SC
Price Weight lb(kg) Description
Use with
<--->
0.2(0.09)
Operator shaft, type D, 7.9” (200 mm) length, 5x5 mm thick (purchase handle separately)
SCV30
<--->
0.3(0.14)
Operator shaft, type D, 12.6” (320 mm) length, 5x5 mm thick (purchase handle separately)
SCV30
<--->
0.15(0.07)
Operator shaft, type G, 4.7” (120 mm) length, 5x5 mm thick (purchase handle separately)
SCV30
<--->
0.3(0.14)
Operator shaft, type G, 7.9” (200 mm) length, 10x10 mm thick (purchase handle separately)
SCV60 thru SCV400
<--->
0.2(0.09)
Operator shaft, type G, 7.9” (200 mm) length, 5x5 mm thick (purchase handle separately)
SCV30
<--->
0.5(0.23)
Operator shaft, type G, 12.6” (320 mm) length, 10x10 mm thick (purchase handle separately)
SCV60 thru SCV400
<--->
0.2(0.09)
Operator shaft, type G, 12.6” (320 mm) length, 5x5 mm thick (purchase handle separately)
SCV30
<--->
0.7(0.32)
Operator shaft, type G, 15.7” (400 mm) length, 10x10 mm thick (purchase handle separately)
SCV60 thru SCV400
<--->
2.1(0.95)
Operator shaft, type H, 17.7” (450 mm) length, 15x15 mm thick (purchase handle separately)
SC600, SC800
<--->
0.1(0.05)
Direct operation handle
SCV30
<--->
0.4(0.18)
Direct operation, optional handle, 12.415” (315.314 mm) long padlocking on the switch, NFPA 79 compliant SCV30
<--->
0.4(0.18)
Direct operation, optional handle, 12.415” (315.314 mm) long padlocking on the switch, NFPA 79 compliant SCV60 thru SCV400
<--->
0.2(0.09)
Black Pistol handle, NEMA 12, 2.48” (63 mm) long, Type D, defeatable and lockable
SCV30
<--->
0.2(0.09)
Red and yellow Pistol handle, NEMA 12, 2.48” (63 mm) long, Type D, defeatable and lockable
SCV30
<--->
0.5(0.23)
Black Pistol handle, NEMA 12, 2.78” (70.6 mm) long, Type G, defeatable and lockable
SCV30
<--->
0.6(0.27)
Black Pistol handle, NEMA 4X, 2.78” (70.6 mm)long, Type G, defeatable and lockable
SCV30
<--->
0.7(0.32)
Black long Pistol handle, NEMA 4X, 4.98” (126.49 mm) long, Type G long, defeatable and lockable
SCV60 thru SCV400
<--->
0.6(0.27)
Black long Pistol handle, NEMA 12, 4.98” (126.49 mm) long, Type G long, defeatable and lockable
SCV60 thru SCV400
<--->
0.6(0.27)
Red and yellow Pistol handle, NEMA 12, 2.78” (70.6 mm) long, Type G, defeatable and lockable
SCV30
<--->
0.6(0.27)
Red and yellow Pistol handle, NEMA 4X, 2.78” (70.6 mm) long, Type G, defeatable and lockable
SCV30
<--->
0.6(0.27)
Red and yellow long Pistol handle, NEMA 4X, 4.98” (126.49 mm) long, Type G long, defeatable and lockable SCV60 thru SCV400
<--->
0.6(0.27)
Red and yellow long Pistol handle, NEMA 12, 4.98” (126.49 mm) long, Type G long, defeatable and lockable SCV60 thru SCV400
<--->
1.3(0.59)
Black Pistol handle, NEMA 4X, 7.48”(190 mm) long, Type H, defeatable and lockable
SC600, SC800
Price Weight lb(kg) Description
Use with
<--->
0.2(0.09)
Auxiliary contact holder (accommodates up to 4 auxiliary contacts)
SCV30
<--->
0.2(0.09)
Auxiliary contact holder (accommodates up to 8 auxiliary contacts)
SCV60 thru SCV400
<--->
0.1(0.05)
Auxiliary contact holder (accommodates up to 4 auxiliary contacts)
SC600, SC800
<--->
0.1(0.05)
Auxiliary contact for SIRCO non-fused disconnect switches. One N.O. contact. 10 Amp, 600 VAC
All SIRCO switches
<--->
0.1(0.05)
Auxiliary contact for SIRCO non-fused disconnect switches. One N.C. contact. 10 Amp, 600 VAC
All SIRCO switches
<--->
0.4(0.18)
Terminal lug kit, Aluminum, tin-plated, 3/0 to #6, 6 lugs per kit
SCV200
<--->
5.0(2.27)
Terminal lug kit, Aluminum, tin-plated, 600Mcm to #2, 6 lugs per kit
SCV400
<--->
5.0(2.27)
Terminal lug kit, Aluminum, tin-plated, (2) 600Mcm to #2, 6 lugs per kit
SC600
<--->
10.0(4.5)
Terminal lug kit, Aluminum, tin-plated, (3) 600Mcm to #2, 6 lugs per kit
SC800
<--->
0.7(0.32)
Terminal shroud kit - 3 pole, Use with 200 amp non-fusible switch. For line or load side.
SCV200
<--->
0.7(0.32)
Terminal screen kit - 3 pole, Use with 800 amp non-fusible switch, For line or load side.
SC800
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Ferraz Non-Fusible Disconnects Accessories Selection Guide
Part Number
ACHCD
ACH
ACHSC
AC3
AC4
TL200
TL400
TL600
TL800
TS200SC*
TS1200SC*
Motor
Controls
Circuit Protection
e31-65
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Non-Fusible Disconnects SIRCO
Series - Build a Complete Switch
30 Amp
STEP 1
STEP 2
STEP 3
Choose a switch body
Choose a handle
Choose a shaft
DIN-rail mountable
Switch body
Switch
Body
SCV30*
Ampere Hp @
Rating Voltage
30
15 Hp @ 480V
Short handles
Interrupt
Capacity
(kA)
50
Short handle shafts
Short Handle
HDPB Pistol, Black, NEMA 1, 3R, 12, Type D
HDPR Pistol, Red/yellow, NEMA 1, 3R, 12, Type D
Shaft for Short Handle
SD200-5 Type D, 7.9” (200 mm) long
SD320-5 Type D,12.6” (320 mm) long
*Note: Lugs, shrouds, and screens are integrated
into this switch
Standard handle shafts
Standard handles
Standard Handle
HGPB Pistol, Black,NEMA 1, 3R, 12, Type G.
HGPB4 Pistol, Black, NEMA 4, 4X, Type G,
HGPR Pistol, Red /yellow, NEMA 1, 3R, 12, Type G
HGPR4 Pistol, Red /yellow, NEMA 4, 4X, Type G
Shaft for Standard Handle
SG120-5 Type G, 4.7” (120 mm) long
SG200-5 Type G, 7.9” (200 mm) long
SG320-5 Type G,12.6” (320 mm) long
Direct handles
Direct Mount Handle
HADB1 Direct mount, Black. No shaft required.
Shaft not used with Direct Handle
NFPA 79 compliant handle
Select a standard handle.
NFPA 79 Compliant Handle
HADB6
NFPA 79-compliant, allows operation
and padlocking the switch when door is
open. Red. No shaft required.
Note: Short handle cannot be used with
NFPA79-compliant handle.
STEP 4
Choose your Accessories
Accessories Description
ACHCD
AC3
AC4
Auxiliary contact holder (accommodates up to 4 auxiliary contacts).
REQUIRED when using AC3 or AC4.
Auxiliary contact. One N.O. contact. 10 Amp. 600 VAC
REQUIRES ACHCD . Please purchase separately.
Auxiliary contact. One N.C. contact. 10 Amp. 600 VAC
REQUIRES ACHCD . Please purchase separately.
Use With
SCV30
SCV30
SCV30
ACHCD
AC3
AC4
Volume 13
e31-66
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects
SIRCO Series - Build a Complete Switch
Systems
Overview
Programmable
Controllers
60 Amp to 400 Amp
STEP 1
Choose a switch body
Company
Information
STEP 2
Field I/O
STEP 3
Software
Choose a shaft
Choose a handle
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Switch body
Hp @
Switch Body Ampere
Rating Voltage
SCV60*
SCV100*
SCV200**
SCV400***
Standard handle shafts
Standard handles
Interrupt
Capacity
(kA)
60
30 Hp @ 480V
200
100
60 Hp @ 480V
200
200
125 Hp @ 480V
200
400
200 Hp @ 480V
200
Standard Handle
HGPBL
HGPB4L
HGPRL
HGPR4L
Shaft for Standard Handle
SG200-10 Type G, 7.9” (200 mm) long
SG320-10 Type G, 12.6” (320 mm) long
SG400-10 Type G, 15.7” (400 mm) long
Pistol, Long Black, NEMA 1, 3R, 12;
4.98” long, Type G
Pistol, Long Black, NEMA 4, 4X,
4.98” long, Type G
Pistol, Long Red/yellow NEMA 1, 3R, 12;
4.98” long, Type G
Pistol, Long Red/yellow NEMA 4, 4X,
4.98” long, Type G
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
*Note: Lugs, shrouds, and screens are integrated into
this switch.
Encoders
**Note: Line side screen included with this switch.
Use TL200 lugs and TS200SC screen, sold
separately, for load side.
Current
Sensors
***Note: Screens and shrouds are integrated into this
switch. Use TL400 lugs, sold separately.
Pressure
Sensors
Temperature
Sensors
NFPA 79 compliant handle
NFPA 79 Compliant Handle
HADB8
Pushbuttons/
Lights
Select a standard handle
Process
NFPA 79-compliant, allows operation
and padlocking the switch when door is
open. Red. No shaft required.
Relays/
Timers
Comm.
STEP 4
Choose your Accessories
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
ACH
AC3
AC4
TL200
TL400
Tools
TS200SC
Pneumatics
Accessories
ACH
AC3
AC4
TL200
TL400
TS200SC
Description
Use With
Appendix
Auxiliary contact holder (accommodates up to 8 auxiliary contacts). REQUIRED when using AC3 or AC4.
Auxiliary contact. One N.O. contact. 10 Amp. 600 VAC. REQUIRES ACH . Please purchase separately.
SCV60 thru SCV400
Product
Index
Auxiliary contact. One N.C. contact. 10 Amp. 600 VAC. REQUIRES ACH . Please purchase separately.
Terminal lug kit, Aluminum, tin-plated, 3/0 to #6, 6 lugs per kit
SCV200
Terminal lug kit, Aluminum, tin-plated, 600Mcm to #2, 6 lugs per kit
SCV400
Terminal shroud kit, - 3 pole, Use with 200 amp non-fusible switch. For line or load side. 3 shrouds per kit.
SCV200
Part #
Index
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-67
Non-Fusible Disconnects
SIRCO Series - Build a Complete Switch
600 Amp to 800 Amp
STEP 1
STEP 2
STEP 3
Choose a switch body
Choose a handle
Choose a shaft
Switch Body
Long Handle
Shaft for Long Handle
Switch
Body
Ampere Hp @
Rating Voltage
SC600*
SC800**
Interrupt
Capacity
(kA)
600
400 Hp @ 480V
200
800
500 Hp @ 480V
100
Long Handle
HHPB4SC
Shaft for Long Handle
SH400-15 Type H, 17.7” (450 mm) long
Black, NEMA 4, 4X;
7.48” long, Type H.
*Note: Line side screen included with this switch.
Use TL600 lugs, sold separately.
**Note: Line side screen included with this switch.
Use TL800 lugs and TS1200SC screen, sold
separately, for load side.
STEP 4
Choose your Accessories
ACHSC
AC3
Accessories
ACHSC
AC3
AC4
TL600
TL800
TS1200SC
AC4
TL600
TL800
TS1200SC
Description
Use With
Auxiliary contact holder (accommodates up to 4 auxiliary contacts). REQUIRED when using AC3 or AC4.
SC600 thru SC800
Auxiliary contact. One N.O. contact.10 Amp. 600 VAC. REQUIRES ACHSC. Please purchase separately.
SC600 thru SC800
Auxiliary contact. One N.C. contact.10 Amp. 600 VAC. REQUIRES ACHSC. Please purchase separately.
SC600 thru SC800
Terminal lug kit, Aluminum, tin-plated, (2) 600Mcm to #2, 6 lugs per kit
SC600
Terminal lug kit, Aluminum, tin-plated, (3) 600Mcm to #2, 6 lugs per kit
SC800
Terminal screen kit - 3 pole, Use with 800 amp non-fusible switch, For line or load side. 1 screen per kit.
SC800
Volume 13
e31-68
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects SIRCO
Series Specifications
Company
Information
Systems
Overview
Programmable
Controllers
SIRCO Non-Fusible Disconnects Technical Specifications According to UL 508, cUL and CSA
Specifications
Part Number
SCV30
SCV60
<--->
<--->
Price
600
600
Rated Operational Voltage (VAC)
50
200
Short Circuit Rating (kA) with fuses
J or CC
J
Fuse Type (if fusing separately)
30
60
Fuse Rating (A) (if fusing separately)
Maximum UL Horsepower/Maximum Motor FLA Current, Three Phase
5/17.5
15/48.5
208V
7.5/22
15/42
240V
15/21
30/40
480V
20/22
50/52
600V
3/251
DC 125V 3/251
1
10/382
DC 250V 5/20
21
88
Switch Operating Torque lb-in
#10 - #14 (1) #3 - #10 (1)
Wire Size Range AWG (# wire holes per lug)
Integral
Integral
Terminal Lugs Kit (# of lugs per kit)
27
58
Wire Tightening Torque lb-in
3.9(1.79)
4.0(1.80)
Net Weight lb(kg)
Field I/O
SCV400
SC600
SC800
<--->
<--->
<--->
<--->
<--->
600
600
600
600
600
200
200
200
200
100
J
J
J
J
L
100
200
400
600
800
Soft
Starters
25/78.5
50/150
100/286
150/415
200/554
30/80
60/154
125/312
200/480
250/602
Motors &
Gearbox
60/77
125/156
250/302
400/447
500/590
75/77
150/144
350/336
350336
500/472
7.5/581
15/1121
20/1481
20/1481
–
2
2
–
2
20/72
40/140
50/173
50/1732
88
106
130
320
C-more &
other HMI
Drives
320
#3 - #10 (1) #3/0 - #6 (1) 600 kcmil-#2 (2) 600 kcmil-#2 (2) 600 kcmil-#2 (3)
Integral
Optional (6) Optional (6)
Optional (6)
Optional (6)
58
200
500
500
500
5.5(2.50)
7.6(3.40)
17.2(7.80)
18.7(8.50)
19.6(8.90)
Note: 1: 2-pole in series
2: 3-pole in series
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Current
Sensors
Part Number
Unit
SCV30
SCV60
SCV100 SCV200 SCV400 SC600
SC800
Rating
Rated Insulation Voltage Ui (V)
Rated impulse Voltage (Uimp)
Operation Current Ie (A)
A
32
63
100
200
400
600
800
V
800
750
750
750
800
1000
1000
8 kV
8 kV
8 kV
8 kV
8 kV
12 kV
12 kV
690 VAC
Steppers/
Servos
Encoders
IEC 947-3 Technical Specifications For Front Operation
400 VAC
Software
SCV100 SCV200
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
IEC
Utilization
Category
Unit
AC 22A
A
32
63
100
200
400
630
800
AC 23A
A
32
63
100
200
400
630
800
AC 22A
A
32
63
100
200
400
500
630
AC 23A
A
32
63
100
200
315
200
400
Terminal
Blocks &
Wiring
A
15
30
51
100
220
355
450
Power
A
18.5
40
63
140
220
450
560
A
25
55
90
185
295
185
400
Circuit
Protection
kA peak
5.5
17.6
17.6
32
40
48
75
mm2
mm2
6
10
25
50
185
2x150
2x185
—
—
—
—
—
2x30x5
2x40x5
Motor Power (kW)
AC 23A
400 VAC
AC 23A
500 VAC
AC 23A
690 VAC
Maximum Peak Let-through Current (gG)
Connection
Minimum CU Cable Section
Minimum CU Busbar Section
Process
Relays/
Timers
Comm.
Enclosures
Tools
Pneumatics
Appendix
Note: See Appendix for IEC utilization categories.
Product
Index
Part #
Index
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-69
Non-Fusible Disconnects
SIRCO Series Dimensions
SCV30
A
C
Y
J
J1
Y
K1
35 mm Din-rail
mount
X
B
K
Mounting hole
2x diameter 0.20” (5 mm)
SCV60
SCV100
Mounting hole
4x diameter 0.20” (5 mm)
J
C
10.3
J1
29
Y
K1
X
126.5
Y
Part
Number
Number
of Poles
A
in
B
mm
in
in
B
A
C
mm
K
H
H1
H2
H3
J
mm
in
mm
in
mm
in
mm
in
mm
in
J1
mm
in
mm
K
in
K1
Y
mm
in
mm
in
1
25.5 1.12 28.5
mm
SCV30
3
3.78 96 4.56 116 2.59 66
–
–
–
–
–
–
–
–
1.47 37.5 0.59 15 3.13 79.5
SCV60
3
6.69 170 5.87 149 3.89 99
–
–
–
–
–
–
–
–
1.5
38 2.75 69.5 5.25 133.5 2.63 66.5 0.95 24.5
SCV100
3
6.69 170 5.87 149 3.89 99
–
–
–
–
–
–
–
–
1.5
38 2.75 69.5 5.25 133.5 2.63 66.5 0.95 24.5
Volume 13
e31-70
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects
SIRCO Series Dimensions
Company
Information
Systems
Overview
Programmable
Controllers
SCV200
C
J
10.3
Field I/O
J1
29
Software
M8
C-more &
other HMI
H2
Drives
Y
K1
X
Soft
Starters
K
166
126.5
B
Motors &
Gearbox
H3
Steppers/
Servos
H2
Motor
Controls
Proximity
Sensors
Mounting hole
4x diameter 0.20” (5 mm)
Y
A
Photo
Sensors
Limit
Switches
SCV400
Encoders
C
J
10.3
J1
29
Current
Sensors
M 10
Pressure
Sensors
Temperature
Sensors
H2
Y
K1
X
B
126.5
Pushbuttons/
Lights
176 K
Process
Relays/
Timers
H3
Comm.
H2
Terminal
Blocks &
Wiring
Power
J
Y
Circuit
Protection
A
Enclosures
Part
Number
Number
of Poles
A
B
in
mm
242
in
C
mm
in
H
H1
H2
mm
in mm in mm in
mm
H3
in
mm
J
in
J1
mm
in
mm
K
in
mm
K1
Y
in mm in mm
SCV200
3
9.52
8.13 206.5 3.42
87
–
–
–
– 6.87 174.5 4.39 111.5 2.44 62 3.68 93.5 7.5 190.5 3.74 95 0.95 24.5
SCV400
3
11.93 303 14.31 363.5 4.92
125
–
–
–
– 7.04 179 6.59 167.5 2.84 72 2.04 52 8.82 224 4.41 112 1.06 27
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-71
Non-Fusible Disconnects
SIRCO Series Dimensions
SC600
J
C
Y
J1
Ø 13
H
Mounting hole
4x diameter 0.20” (5 mm)
Y
K1
X
K2
H2
K
B
H
80
H1
A
SC800
J
C
40
J1
0.78 0.78
20 20
Y
Ø 11
Mounting hole
4x diameter 0.05” (1 mm)
H
Y
K1
X
K2
B
2
K 290
1
215.5 225
H
K
2
1
H1
120
Part
Number
Number
of Poles
A
in
B
mm
in
C
mm
in
H
mm
H1
H2
in mm in mm in
J
mm
in
J1
mm
SC600
3
11.02 280 12.60 320
5.51
140 9.05 230 5.43 138 8.66 220 10.04 255
SC800
3
14.64 372
5.51
140 9.05 230 5.43 138
13
330
–
–
A
in
mm
K
in
K1
mm
in
mm
K2
Y
in mm in mm
5 127.5 6.88 175 2.34 59.5 1.10 28 1.85 47
13.66 347 6.83 173.5 6.88 175 2.34 59.5 1.10 28 1.85 47
Volume 13
e31-72
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects
SIRCO Series Dimensions
Company
Information
Systems
Overview
Programmable
Controllers
Handles for external front operation
Field I/O
PISTOL HANDLE TYPE D (short)
PISTOL HANDLE TYPE G (standard)
Software
DOOR DRILLING
DOOR DRILLING
dia. 0.17 in (4.5 mm)
46.5
73
dia. 1.22 in (31 mm)
70
dia. 0.17 in (4.5 mm)
Drives
X
2.78
7 0 .5
2.48
63
O
G1
°
90
1.97 in
50 m m
O
Soft
Starters
°
90
Motors &
Gearbox
I
G2
I
4.98
126.5
1.97 in
50 mm
Y
X
C-more &
other HMI
dia. 1.22 in (31 mm)
Y
1.97 in
50 mm
2
65.5
Steppers/
Servos
PISTOL HANDLE TYPE H (long)
3.15
80
Motor
Controls
DOOR DRILLING
Proximity
Sensors
50 2"
7.48
190
50 2"
Photo
Sensors
31 1 1 4 "
Limit
Switches
4.5
1 8"
Encoders
3.93
100
Current
Sensors
Pressure
Sensors
Backplate-to-door distance with shaft extension (in/mm)
MINIMUM DISTANCE
(in/mm)
h Minimum
Dimension
Handle Type D Handle Type G Handle Type H
SCV30
h
Temperature
Sensors
in
mm
in
mm
in
mm
4.53
115
3.74
95
–
–
SCV60 to SCV100
–
–
4.73
120
–
–
SCV200
–
–
4.33
110
–
–
SC400 to SC600
–
–
–
–
8.35
212
SC800
–
–
–
–
8.35
212
Comm.
Circuit
Protection
SCV30
X
Relays/
Timers
Power
PISTOL HANDLE TYPE G
SCV30
Process
Terminal
Blocks &
Wiring
Shaft trimming length (Dimension L)
PISTOL HANDLE TYPE D
Pushbuttons/
Lights
X
Enclosures
26 ±4
d oor
d oor
19±2
Tools
Pneumatics
Appendix
min.
min.
10
L = X-63
Product
Index
10
Part #
Index
L = X-37
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-73
Non-Fusible Disconnects
SIRCO Series Dimensions
Backplate-to-door distance with shaft extension, continued (in/mm)
PISTOL HANDLE TYPE G
SCV60
SCV60
SCV100
SCV100
SCV200
SCV200
PISTOL HANDLE TYPE G
SCV400
SCV400
L
min.
L
L = X-30
min.
30
PISTOL HANDLE TYPE H
SC600
SC600
SC800
SC800
L
L = X-30
30
L
L = X-22
min.
X
max.
30.5
X
X
min.
max.
30.5
Handle for direct front operation
HADB1
HADB1
98
HANDLES FOR DIRECT FRONT OPERATION
K
NFPA 79 Compliant Switches
HADB6
m i n . 1 i n / 2 5 .5 m m
m ax. 1 .1 2 i n / 2 8 .5 m m
HADB8
m i n . 1 .0 2 i n / 2 6 m m
m ax. 1 .1 4 i n / 2 9 m m
H min. 12 in / 305 mm
min. 10 in / 254 mm
H
m in. .39 in
m i n . 10 m m
L
L
L
L
L
m i n . = H - 3 .8 i n
m i n . = H - 9 6 .5 m m
m ax. = H - 4 .0 7 i n
m ax. = H - 1 0 3 .5 m m
L
L
L
L
L
m i n . = H - 0 .7 3 i n
m i n . = H - 1 8 .5 m m
m ax. = H + 0 .4 5 m m
m ax. = H + 1 1 .5 m m
Volume 13
e31-74
Circuit Protection
1 - 80 0 - 633 - 0405
Non-Fusible Disconnects
SIRCO Series Dimensions
Company
Information
Systems
Overview
Programmable
Controllers
Terminal Lugs
TL200
Field I/O
Use with SCV200 switch
Software
Tap 7/16 (0.4375)-20UNF-28 x 0.52
dia. 0.350 thru
C-more &
other HMI
7/16-20 x 0.62 LG
Aluminum screw with
0.188 hex. Assemble screw
snug to bottom (2-15 in-lbs)
0.780
Drives
Soft
Starters
0.390
0.407 REF
Motors &
Gearbox
0.406
1.609
dia. 0.531 thru
0.06 x 90°
0.800
Steppers/
Servos
Motor
Controls
dimensions = inches
Proximity
Sensors
1.125
0.562
Photo
Sensors
0.234
0.125
Limit
Switches
0.125
0.393
Encoders
0.800
1 wire 3/0 - #6
Current
Sensors
TL400, TL600
For use with SC800 switch
Use with SCV400, SCV600
Use with SC800
TL800
Tap 13/16 (0.812) - 16UNF -2B
to 0.25 off bottom of wireway
2 plcs
dia. 0.406 thru
Pressure
Sensors
Temperature
Sensors
dia. 0.4375
Pushbuttons/
Lights
1.500
0.750
0.590
REF
1.563
13/16-16 x 1.00 LG
aluminum screw with .375 Hex
assemble screw snug to
bottom (5-25 in-lbs)
2.5
Process
Relays/
Timers
0.687
1.968
Comm.
3.563
3.750
2.562
Terminal
Blocks &
Wiring
dia. 0.938 x 2.60
0.06 x 90°
1.375
Power
3.000
dia. 0.938 x 2.60
0.06 x 90°
3.000
2.250
Circuit
Protection
Enclosures
1.125
Tools
1.094
0.750
0.125
Pneumatics
Appendix
0.827
2 wire Kcmil#2
Product
Index
3 wire Kcmil#2
Part #
Index
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-75
Download