QUICKSTART “BASIC” GUIDELINES FOR 115 VAC STANDARD OR

advertisement
QUICKSTART “BASIC” GUIDELINES FOR 115 VAC STANDARD OR DELUXE CONTROL BOX FOR 6002, 6003, 6004 AND 6400
Control box is intended for installation only on automated gates used for vehicles.
Main Terminal
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
D
KEY SWITCH BUTTON: Cycles operator when pressed.
Will use Auto-Close timer when turned ON.
E
RESET BUTTON: Resets circuit board.
Circuit Board Settings
Typical Settings with Plug-In Reverse, Shadow and Exit Loops
Mounting Holes
Shadow
Loop
Reverse loops wired in series
To #8
To #11
SW 2
NO
#1 ON
#2 OFF
NC
6
#8 - #11 Shadow Loop Output
7 8 9 10 11 12 13 14 15 16 17 18 19 20
Antenna
mounted
outside
control box.
15
x
Ft Coa
PRIMARY
Operator Cable
SECONDARY
Operator Cable
(Interconnection
Cable)
DO NOT cycle operator before limit sensors
Com
Telephone Entry
Note: Must use a
separate power source.
and DIP-switches have been adjusted,
damage could occur to gate and operator.
Please refer to the Wiring/Owner’s manual for
the 115 VAC Control boxes.
Copyright 2011 DoorKing, Inc. All rights reserved.
Low Voltage
Key Switch
(Dry contact)
Coaxial Cable Antenna Kit
P/N 1514-073 (Sold separately)
Battery Plug
CAUTION
SW 1
Switch 3
MUST be
ON.
Mounting
Hole
Not included - Refer to a specific Radio Receiver
Manual (available from www.dkaccess.com) for
more information on radio receivers and antenna
installation.
RED
g
DoorKin
e
ir
3-W
eiver
RF Rec
5-081
5
0
8
P/N
ON
Keypad
(Dry contact)
Shadow
Loop
Jumper
C
RED 24V
5
Radio Receiver
AC Power
Switch
Loop
Wires
Alarm Chassis
Reset Ground
Button
Tip: Never run low voltage
rated wire insulation in the
same conduit as high voltage
rated wire insulation. Keep
them in separate conduits.
High Voltage
Power
Relay
Com
12 V
3 Amp/Hr
Battery
Reversing
Sensor
Adjust
Relay
N.O.
N.O.
Three 115 VAC Convenience Outlets
12 V
3 Amp/Hr
Battery
B
Com
N.O.
Deluxe
Control
Box
2 3 4
Note:
Please refer to the
Wiring/Owner’s
manual.
Not included - Refer to the Wiring/Owner’s manual
AND Loop Information Manual (available from
www.dkaccess.com) for more information on
loops and plug-in loop detectors.
Important Note: DoorKing highly recommends that
loops and loop detectors are installed with this
gate operator. A loop detection system will
preventing the gate from automatically opening or
closing on a vehicle when it is in the gate’s path.
Battery Plug
BLK 115V WHT
1
ON
D
Controls must be far
enough from the gate so
that the user is prevented
from coming in contact
with the gate while
operating the controls.
1 2 3 4
Primary
Operator
ONLY
1 2 3 4
Safety Opening Device
Com (Dry contact)
ON
1
2
3
4
5
6
7
1. Relay Control
2. Relay Control
3. Maglock
4. OFF
Plug-In Loop Detectors
SW 1
Com
Power safety and opening devices
that require 115 VAC power.
#5 OFF
SW 1
1. Direction Primary operator opens.
2. Direction Secondary operator opens.
3. Open Input
4. Auto-Close Timer
B
5. Standard Reverse
6. Overlapping Gates
7. Single/Dual Operators Adjust11 to23
23 sec.
8. OFF
SW 2
E
A
Secondary
Operator Shadow Loop
ONLY
Settings:
Note: Circuit board provides
24 VDC to power maglock.
Contact rating is 1 amp
maximum at 24 Volts.
N.O.
Common
Switch 3 ON
1 2 3 4 5 6 7 8
4-Wire
RF Receiver
SW 2
1 2 3 4 5 6 7 8
Relay Com
Power Com
Secondary
Entrapment
Protection
Device
Connection
N.O.
Connect optional control devices to
the main terminal. Use 18 AWG wire
for all low voltage wiring, maximum
distance 3000 feet. Use a low voltage
surge suppressor, (DoorKing P/N
1878-010) if low voltage wire runs
exceed 1000 feet. All control device
inputs to the terminal must be
NORMALLY OPEN.
Relay
N.C.
ON
Power
Com
ON
3-Wire
RF Receiver
Do not power any control
devices from the circuit
board other than low
voltage devices.
Magnetic Lock
1 2 3 4
Reversing input on
Terminal #8
functions ONLY
while the gate is at
the FULL OPEN
position or during the CLOSING
cycle. It MUST NOT be used as an
input for a secondary entrapment
protection device during the
OPENING gate cycle. Refer to
Secondary Entrapment Protection
Wiring in the Wiring/Owner’s
manual.
Dual Channel
Reverse and Shadow
Plug-In Loop Detector
P/N 9409-010
Single Channel Exit
Plug-In Loop Detector
P/N 9410-010
A
ON
9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8
24 VAC Input
24 VAC Input
Low Voltage Common
Alarm Reset
Not Used
12 Volt Battery Input
Not Used
DC Lock Power Common
24 VDC Maglock Power
Low Voltage Common
7 8
Dry Relay Contact
Full Open
6
Dry Relay Contact
Low Voltage Common
5
Low Voltage Common
Full Open
2 3 4
Standard Reverse
Full Open
24 VDC - 250 ma max.
Low Voltage Common
1
Pedestrians must be supplied with a separate access opening.
For safety and complete installation and adjustment instructions, please refer to the Wiring/Owner’s manual.
115 VAC Input
Power Wire:
Wire Size
Distance
14 AWG
12 AWG
Up to 200 ft
Beyond 200 ft
Black to transformer’s black (Hot).
White to transformer’s white (Neutral).
Green to chassis ground.
Do not connect the battery plug to the
circuit board until power is needed to test
the operator.
115 VAC Connection
BOX MUST BE
DANGER CONTROL
PROPERLY GROUNDED!!
C HIGH VOLTAGE!
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Tip: It is recommended
that a surge suppressor
be installed on the high
voltage power lines.
Note: To turn-off ALL power to the operator, the AC
power switch must be turned off AND the battery
plug must be disconnected from the circuit board.
4302-066-D-10-11