Fuse Fitting Brochure

advertisement
Fuse Holders,
Bases & Disconnects
Contents
RSM Fuse Holders & Accessories
Red Spot Fuse Holders & Accessories
Safeclip Fuse Holders & Accessories
Modular Fuse Holders
DIN Fuse Bases & Accessories
DIN Fuse Disconnects – Horizontal
DIN Fuse Disconnects – Vertical
Series 7 Fuse Holders
RSL Fuse Holders
2
■
■
■
■
■
■
World leading Red Spot quality at the right price
Smallest BS88 bolt-in fuse holders available
Silver plated as standard
Fully shrouded for personal safety
Insulating sleeves supplied with front wired versions for extra protection
Suitable as current limiters when fitted with fuse links
RSM Red Spot Fuse Holders
Rating
A
Type
Colour
Connection
Recommended
max. cable size
Associated fuse link
32A
RSM32H
Black
Front wired
10mm2
NIT2-32 (415V, 550V)
63A
RSM63H
Black
Front wired
25mm2
TIA / TIS
2
100A
RSM100H
Black
Front wired
50mm
TIS / OS
160A
RSM160H
Black
Front wired
95mm2
TCP / TFP
Accessories
Pad-lockable Inserts
RS20LOCK
Suits RSM32
RS32LOCK
Suits RSM63
RS63LOCK
Suits RSM100
RS100LOCK
Suits RSM160
DIN Rail Adaptor
RS20A
Suits RSM32
White Fuse Fittings (to match size of RSM black fuse fittings)
Type
Associated Black Fuse Fitting
Copper Link Type Number
RS20HWH
RSM32H
RS20CLINK
RS32HWH
RSM63H
RS32CLINK
RS63HWH
RSM100H
RS63CLINK
Copper Link Ratings
RS20CLINK=32A
RS32CLINK=63A
3
RS63CLINK=100A
RS100CLINK=200A
RSM FUSE HOLDERS & ACCESSORIES
Red Spot Miniature Fuse Holders
Panel Drilling Dimensions
(viewed from front of panel)
RSM FUSE HOLDERS & ACCESSORIES
32A
63A
100A
160A
RSM32H
RSM63H
RSM100H
RSM160H
mm
N
P
U
V
6.4
3.2
9.5
11.1
RSM Dimensions
32, 63, 100 & 160 amp
Front Connected
Rating Amp
A
B
C
H
J
X
Y
Z
32
27
29
55
15
16
60
6.6
37
mm
63
32
103
70
15
22
7.0
5.6
49
mm
100
35
110
75
15
24
9.5
5.6
54
mm
160
51
140
100
15
28
14
7.2
74
mm
4
Red Spot Fuse Fittings
■
■
■
■
Fuse fittings to AS2005.21.2 – 1990, BS88: Part 2: 1988, 660 volts AC/DC.
Approved by leading authorities and used in equipment approved by Lloyds.
Full Shrouding for personnel
safety and complete compliance
with the direct contact electric
shock requirements.
Insulating sleeves are fitted to
front connected fuse bases to
provide increased protection at
the cable entry point.
Separate base contact insulating
shrouds of great strength and
flexibility ensure that no “live”
metal is dangerously exposed
when the fuse carrier is removed.
Anti-vibration features protect
against release of a fuse-carrier
due to vibration in service. In the
400 amp size this includes a safety
catch which automatically locks on
the insertion of the fuse carrier.
Type Numbers
Alternative type of connection
Rating amp
Front
Back
Front/Back
Back Wired
20
RS20H*
RS20P
RS20PH
RS20BW
32
RS32H
RS32P
RS32PH
RS32BW
63
RS63H
RS63P
RS63PH
RS63BW
100
RS100H
RS100P
RS100PH
RS100BW
200
RS200H
RS200P
RS200PH
400
RS400H
RS400P
Illustrations & dimensions shown on pages 8-11
Recommended Maximum Cable Sizes
Rating amp
BW types
10mm
2
10mm2
25mm
2
16mm2
63
50mm2
35mm2
100
95mm2
70mm2
20
32
Cut-away view of 63 amp front
connected contact assembly
H and PH types
200
400
2
–
2
–
120mm
240mm
5
RS400PH
* For Din Rail Mounting order DIN Rail Adaptor Part No: RS20A
REDSPOT FUSE HOLDERS & ACCESSORIES
Safety Features
Application Data
HRC Fuse Links Accomodated
Extended range of Type ‘T’ to BS.88:Part 2: AS2005.21.2 for motor circuit protection (660V AC)
Fuse Fitting Rating
Amp
Type ‘T’ to BS.88:Part 2 & AS2005.21.2
List No.
REDSPOT FUSE HOLDERS & ACCESSORIES
Current Rating
Amp
Rating for
Motor Starting Amp
20
20
25
32
32
32
32
32
35
40
50
63
TIS63M80
TIS63M100
63
63
80
100
TIA2L-32L†
TIS35L-63L†
TCP80L&100L
TCP100M125
TCP100M160
TCP100M200
100
100
100
125
160
200
TBC2-63A
TC80 & 100A
TF125-200A
TC80L & 100L
TF125L-200L
TF200M250
TF200M315
200
200
250
315
TBC2-63A#
TC80 & 100#
TF125-200#
TKF250 & 315#
TKM250 & 315A
TM355 & 400A
TC80L & 100L#
TKF250L&315L#
TM355L&400L
TM400M450
400
450
550/660V
415V AC
550/660V
20
NIT2-20A
(550 volts a.c.)
NIT2L-20L
NIT20M25
NIT20M32
(415 volts a.c.)
32
TIA2-32A
TIA2L-32L
TIA32M35
TIA32M50
TIA32M50
TIA32M63
63
TIA2-32A
TIS35-63A
TIA2L-32L
TIS35L-63L
100
TIA2-32A†
TIS35-63A†
TCP80 & 100A
200
400
† Adaptor plate required Type ‘A’ 5BB9306-010
415V AC
TIA32M35L
TIA32M40L
TIA32M50L
TIA32M63L
# Adaptor plate required Type ‘B’ 5BB9307-010
Method of Cabling
Front connected 63 amp fuse fitting
Front connected fuse fittings
1. Remove red nylon insulating shroud to release cable sleeve.
2. Remove cable sleeve.
3. Fit cable sleeve over cable.
4. Fit conductor into fuse base terminal and tighten cable clamping screw to
secure. If flexible cables are used, their relatively fine strands may be given
increased protection by the use of thin wall copper ferrules over the conductor.
The following should be taken into account:
a) The inside diameter of the thin wall copper ferrule should match that of the
bared conductor end as closely as possible.
b) The length of the thin wall copper ferrule should match that of the tunnel in
the fuse base terminal.
c) The wall thickness of the ferrule should be thin enough for the ferrule to be
compressed by the tightening of the cable clamping screw. The flexible
conductors will then be consolidated within the deformed ferrule.
5. Replace red nylon shroud taking care that it holds the cable sleeve in position
by locating the shroud in the groove in the sleeves.
6
Dimensions
20A Red Spot Fuse Fittings
Front/Back Connected
Back Connected – Surface
REDSPOT FUSE HOLDERS & ACCESSORIES
Front Connected
mm
A
B
C1
C2
D
E
F
G
H
J
K
L
X
Y
Y2
Z
27.0
79.0
54.0
55.0
63
58.8
M6
13.5
15.0
16
10.10
29
6.0
5.6
6.6
37
Panel Drilling Dimensions (viewed from front of panel)
7
Dimensions
32, 63 & 100 amp Red Spot Fuse Fittings
Front Connected
Front/Back Connected
Back Connected – Surface
REDSPOT FUSE HOLDERS & ACCESSORIES
Rating Amp
A
B
C
D
E
F
G
H
J
K
L
X
Y
Z
32
32
103
70
81.0
73
M6
17.5
15
22
15
29
6.2
5.6
49
mm
63
35
110
75
84.0
78
M8
17.5
15
24
16
29
9.5
5.6
54
mm
100
51
140
100
87
94
M10
22
15
28
23
32
14
7.2
74
mm
Panel Drilling Dimensions (viewed from front of panel)
mm
N
P
Q
R
S
T
U
V
W
6.4
3.2
36.5
41.3
52.4
51.6
9.5
11.1
46.8
8
Dimensions
200 amp Red Spot Fuse Fittings
Front/Back Connected
Back Connected – Surface
REDSPOT FUSE HOLDERS & ACCESSORIES
Front Connected
400 amp Red Spot Fuse Fittings
Rating Amp
A
B
C
200
400
D
E
F
G
H
70
216
98
254.0
J
K
L
M
X
Y
136.5
95
171.5
M12
25
192
114
140
M16
32
Z
22
32
22
32
100.0
16
9.5
84
mm
32
36.5
57
38
151
21
32
130
mm
Panel Drilling Dimensions (viewed from front of panel)
RS400H
RS200H
RS400P & RS400PH
RS200P & RS200PH
N
mm 19.1
P
Q
28.6
85.7
P
9
mm 27.0
Q
69.9
Dimensions
Red Spot Fuse Fittings Back Wired Panel Mounted
REDSPOT FUSE HOLDERS & ACCESSORIES
Type
Rating Amp
A
RS20BW
20
27
RS32BW
32
32
RS63BW
63
35
RS100BW
100
51
B
C
D
E
F
G
All dimensions in mm
80
54
6
30
30
–
103
70
6
40
40
3.2
110
75
6
40
46
3.2
140
100
7
52.6
52.6
11
10
H
J
DIA
K
L
X
Max. Cable
Size mm2
–
8
To suit M5
37
5.3
10
6.4
8
M5
49
5.4
16
6.4
8
M5
54
8.7
35
9.5
16
M6
74
12.7
50
Accessories
Padlockable Insert
Current Rating Amp
Type *
20
RS20Lock
32
RS32Lock
63
RS63Lock
100
RS100Lock
• Because of the variety of suitable locks available,
and customers individual preferences, these
devices are supplied without padlocks.
DIN Rail Adaptor
RS20A for the RS20 range of fittings
Bolted Neutral Links
Fitting Type
Model
20
RS20CLINK
32
RS32CLINK
63
RS63CLINK
100
RS100CLINK
Adaptors to fit Semiconductor Fuse
Links into Red Spot Fuse Fittings
Type
To fit fuses
Fuse Fitting
GSA-1
GSA5 to GSA20
RS32
GSA-2
GSA25 to GSA75
RS100
GSB-2
GSB25 to GSB75
RS100
GSGB16 to GSGB63
RS100
Adaptors to fit small Fuse Links
into larger Red Spot Fuse Fittings
Type
To fit fuses
Fuse Fitting
AA
TIA, TIS
RS100
BA
TBC, TC, TF, TKF
RS400
11
REDSPOT FUSE HOLDERS & ACCESSORIES
When ordering please quote
the following number:
Safeclip Fuse Fittings
Features & Benefits
■
■
■
■
■
■
■
NEW easy to remove fuse carrier.
Self cleaning, self aligning base contacts.
Fuse carriers moulded from tough flame retardant material.
No screws or tools required to fit fuse.
Made from flame retardant thermoplastic or phenolic.
Integral DIN rail mounting feature.
Full shrouding and complete compliance with the direct contact
electric shock requirements.
SAFECLIP FUSE HOLDERS & ACCESSORIES
Rating Amp
20
63
20, 32 & 63A
415/550V AC.
Complying fully with
AS2005.29 – 1990,
BS88 : Part 6 : 1988.
Type of Connection
List Number
Colour
Associated HRC Fuse Lines
Front
SC20H
Black, White
NS2 – 20
NS20M25 & 32
Front
SC32H
Black, White
Back
SC32P
Black, White
Busbar/Front
SC32BH
Black
Busbar/Front
SC32BHA+
Black
Back Wired
SC32BW
Black
Front
SC63H-D
Black, White
NS2 – 32*
Back
SC63P
Black
ES40, 50 & 63
Busbar/Front
SC63BH
Black
ES63M80
NS2 – 32
NS20M25 & 32
* SCA63NS carrier required
Note: All fuse fittings provided with DIN rail facility except: SC32 & 63BH; SC63P
+
Long stud version
Accessories
Adaptor carrier for fitting Type NS
fuse links into SC63 fuse holder
Copper links
Rating
List Number
32
SCA63NS
20/32
63
Recommended Maximum Cable Sizes
Rating amp
H and PH types
20
16mm2
–
32
16mm2
16mm2
63
25mm2
–
12
BW types
SC20/32LINK
ESCLINK
SAFECLIP Fuse Fitting Dimensions
Front Connected
Panel drilling viewed
from front of panel
63A
20 & 32A; 63A
20 to 63A
20 to 63A
Rating
amp
A
B
20 & 32
26.5
75.5
54
16
4
2
–
–
6
M5
63
30
96
58
24
5
6
8
5
8
M5
C
D
E
F
G
H
J
K
Back Connected
Panel drilling viewed from front of panel
32A
63A
Rating
amp
32
63
13
A
B
26.5 75.5
30
96
C
D
E
F
G
H
J
K
L
54
16
5
40
29
M6
2
M5
14
53
16
5
51
32
M8
5
M5
17
SAFECLIP FUSE HOLDERS & ACCESSORIES
20A & 32A
SAFECLIP Fuse Fitting Dimensions
Busbar/Front Connected
32 & 63 amp
Panel drilling viewed from front of panel
SAFECLIP FUSE HOLDERS & ACCESSORIES
Rating
amp
32
32/A*
63
A
B
C
D
E
25
81
47
18
5
1
12
29
6
26.5 75.5 54
16
–
1
40
29
6
20
5
1
12
33
8
6
30
96
* Long stud version
Back Wired
32 amp
14
53
F
G
H
J
K
L
M
N
2
M5
M5
4
2
M6
M5
2
M6
M5
6
Modular Fuse Holders
■
■
■
■
■
■
■
■
Available in 32A, 50A & 125A ratings.
DIN rail mountable.
Made from highly temperature resistant polyamide material.
Available with integral neon fuse blown indicators.
All models (except FMC) are sealable in the closed position.
50A & 125A versions padlockable “open” for maintenance safety.
50A & 125A versions available with a microswitch for remote indication.
Conform to IEC269-2.
CMS221
Amp
32
50
List No.
Type
FMC101
1 Pole, Compact
FMC101S
1 Pole, Compact + Indication
FMC103
3 Pole
CMS141
1 Pole
CMS141S
1 Pole + Indication
CMS141M
1 Pole + Microswitch
Fuse Size
Fuse Ratings
Type
10 x 38
0.5A - 32A
10G
14 x 58
2A - 50A
14G
22 x 58
4A - 125A
22G
CMS141SM 1 Pole + Indication + Microswitch
125
CMS221M
CMS221
1 Pole
CMS221S
1 Pole + Indication
CMS221M
1 Pole + Microswitch
CMS221SM 1 Pole + Indication + Microswitch
Indication refers to fuse blown indication (neon globe built into fuseholder).
Microswitch = 3 pin (NC, NO, C) indicates no fuse, holder open, blown fuse (striker fuses only).
Accessories
List No.
Type
FMP3
Connector pin for multi-pole FMC type holders
MPOLE14
Multi-pole kit for CMS141 – connects up to 10 poles
MPOLE22
Multi-pole kit for CMS221 – connects up to 10 poles
FMC101
15
MODULAR FUSE HOLDERS
Modular Fuse Holder Holders
Technical Features – CMS
Rating
UN(V)
Ulmp
(kV)
Fuse Current
Rating IN(A)
0.25
Maximum Fuse
Operating Current (A)
gG
aM
gRC
UR
0.25
Recommended
Copper Wire
SIze (mm2)
Torque
Maxi
N.m.
0.25
0.5
1
2
4
6
8
CMS141
690
8
FMC101S
10
10
10
12
12
12
3.5
16
16
16
2.5
20
20
20
2.5
25
25
20
4
32
32
25
6
40
40
40
30
30
6
50
50
50
38
35
10
MODULAR FUSE HOLDERS
1
1
2
4
6
8
10
12
16
CMS221
690
8
CMS141M
CMS221
16
20
20
20
4
25
25
25
6
32
32
42
10
40
40
40
6
50
50
50
10
63
51
63
16
80
64
60
25
74
70
35
100
100
125
100
35
4
Modular Fuse Holders and Fuse Links
Cross Section of Typical Modular Fuse Base
1
2
3
4
5
6
Base
Contact
Slide
Handle
Fuse-link
Bolt
Material
■
The fuse holders can be fully
rated provided that the fuse link
does not exceed the holders rated
power acceptance:
FMC101
3W power acceptance
CMS141
4.7W power acceptance
CMS221
9.0W power acceptance
■
De-rating for mounting in
close proximity is as follows:
■
Maximum cable size for the
fuse holders:
10mm compact holder
cable up to 25mm2
14mm holder
cable up to 35mm2
22mm holder
cable up to 35mm2
■
MODULAR FUSE HOLDERS
Base: Polyamide
Handle: Thermal Polyester
Self extinguishable
Contacts: Silver Plated
Protection Index – IP20
Live parts are inaccessible
Dimensions (mm)
Voltage limits for blown fuse
indicator operation:
up to 3 poles
Derating factor = 1
Neon just glowing
65vac/60vdc
between 4-6 poles
Derating factor = 0.8
Neon glowing strong
100vac/100vdc
between 7-9 poles
Derating factor = 0.7
50 Amp
above 10 poles
Derating factor = 0.6
125 Amp 76.5
17
32 Amp
A
B
59
78
C
D
F
78
43
76.5 100.5 45 26.5 107
50.5
103
45 17.5
E
45
35 126.5 50.5
DIN Fuse Bases & Accessories
1
Complies with
DIN43620
IEC269-2-1
690VAC
6
2
3
DIN FUSE BASES & ACCESSORIES
1
2
3
4
5
6
Terminal Shields
NH Fuse Base
Separator
Insulating Dividers
Fuse Shield
DIN Rail Clip (optional)
Size
00
1
2
Rating Amp
160
250
400
3
630
4
1250
5
4
No of poles
Style
Type No
1
OB
NH00GBASE
1
FS
3
OB2D
K-NH00GSHB
Style Legend
3
FS
NH003PSHB
1
OB
NH1GBASE
1
FS
3
OB2D
K-NH1G3PB2D
3
FS
K-NH1G3PSHB
1
OB
NH2GBASE
Size
1
FS
3
OB2D
OB
FS
OB2D
K-NH00G3PB2D
Open base
Fully shrouded IP20
Open base plus 2 dividers
K-NH1GSHB
Spares and Accessories
Dividers
Terminal
Shrouds
Fuse
Covers
Base
Separators
DIN
Rail Clip
K-NH2GSHB
00
NH00GDIV
NH00TS
NH00FC
K-NH2G3PB2D
1
NH1GDIV
NH1TS
NH1FC
NH1SEP
NH00DRC
NH123DRC
3
FS
K-NH2G3PSHB
2
NH1GDIV
NH2TS
NH1FC
NH1SEP
NH123DRC
1
OB
NH3GBASE
3
NH3GDIV
NH3TS
NH3FC
NH3SEP
NH123DRC
1
FS
K-NH3GSHB
3
OB2D
K-NH3G3PB2D
3
FS
K-NH3G3PSHB
1
OB
NH4BASE
Extractor Handle
18
NH-HANDLE
Sizes 000 – 4
NH Base Dimensions
Dimensions
Size 00
N
M
Q
A
B
F
F
D
E
H
G
O
L
I
C
K
P
J
R
B
C
D
20 117 100
E
F
G
8
2
14
H
J
K
L
M
N
O
P
Q
R
8
56
52
85
84
34
1
104
N
A
Dimensions
Sizes 1, 2, 3 & 4
I
25 145 21,5
DIN FUSE BASES & ACCESSORIES
A
32
P
B
G
I
C D H
O
L
E
K
F
Q
J
M
R
S
A
B
NH1-
60
32
209 176 10,5 30 20,5 25
C
D
E
250
35 M10
81
71 122,5 146 65,5 125,5 191 256,5
NH2-
60
35
225 201 10,5 30 20,5 25
250
35 M10
81
89 122,5 146 65,5 125,5 191 256,5
NH3-
60
40
241 210 10,5 30 20,5 25
270
35 M12
81 103 142,5 146 81,5 141,5 223 304,5
NH4-
80
45
312 262
11
F
45
G
–
H
30
19
I
–
J
K
L
M
45 M16 111 145
N
–
O
192
P
–
Q
–
R
–
S
–
DIN Disconnects (horizontal)
DIN Fuse Switch-Disconnectors 690V
IEC 947-3
■
■
■
■
■
■
Type
Rating
Poles
EN 60947
Sizes 00 and 1 can be interlocked and sealed.
Single pole versions available.
DIN fuse switch-disconnectors for 1250 A and 1600 A available in single pole
and three pole versions for size 4a fuse links (800 – 1600A). Details on request.
Type DIND00BB (00/160A) for direct mounting on 60mm busbar systems.
Optimal protection against accidental contact and over reaching.
High short-circuit making capacity and rated breaking capacity provided by
semi-independent manual operation of contacts.
Connection
DIN FUSE DISCONNECTS – HORIZONTAL
DIND003S
160 A
3
STUD
DIND00BB
160 A
3
BUSBAR/STUD
DIND013S
250 A
3
STUD
DIND023S
400 A
3
STUD
DIND033S
630 A
3
STUD
1
Protection against overreaching at the top (GO) prevents
accidental contact with the upper terminal area.
2
Multifunctional front cover.
3
Optional interlocking and sealing facility.
4
Empty space for company logo.
5
Empty space, e.g. for labelling of circuits.
6
Lock slide for test holes.
7
Test holes to contact blades.
8
Disconnector casing with universal connection.
9
Protection against overreaching at the bottom (GU)
prevents accidental contact with the upper terminal area.
VDE 0660
10 Divided shrouding with integrated protection
against overreaching.
11 Busbar adapter for 60mm busbar system.
20
Accessories for DIN Disconnectors Series 9
Busbar Adaptors
For 60mm busbar system. Sizes 1 & 2
Line and Load
Shroud Sets
Cable Clamp Sets
Type
1
BBA01
2
BBA02
Require Clamps
Size
00
1
2
Electronic Fuse Monitoring
Device: EMDS42TA1
Side
Type
Top
GO-LTL00-3
Bottom
GU-LTL00-3
Top
GO-LTL1-3
Bottom
GU-LTL1-3
Top
GO-LTL2-3
Bottom
GU-LTL2-3
For Disconnector
Size
Type
Terminal Range
Min. - Max. mm
00
CLAMP00
1.5 - 70 *
1
CLAMP1
25 - 150 *
2
CLAMP2
25 - 240 *
* Clamp Terminals for Copper
and Aluminium Conductors
DIN FUSE DISCONNECTS – HORIZONTAL
Size
Direct Busbar Mounting
160A Disconnector
Type DIND00BB (00/160A) for direct
mounting on 60mm busbar systems.
To fit: 60mm busbar systems
(centre to centre)
30mm wide busbar
5-10mm thick busbar
21
Technical Data
NH Fuse Switch-Disconnector Series 9
Size 00
Size 1
Size 2
Size 3
Rated operational current le
A
160
250
400
630
Thermal current with solid links
A
210
325
520
820
Thermal current with fuse-links
A
185
290
460
725
Rated voltage Ue
V
690
690
690
690
Rated insulation voltage Ui
V
750
750
750
750
Rated frequency
Hz
40 – 60
Test voltage
kVeff
8
400
630
Maximum DIN NH gG fuse link rating
A
160
250
Maximum DIN semiconductor fuse rating
Call ALSTOM for advice
Insulation group ll to VDE 0110
CTI
400 - 600
Rated making and breaking capacity
at ~400V; cos ϕ = 0,35
A
1250
2500
3800
3800
at ~500V; cos ϕ = 0,35
A
800
1500
2400
3800
at ~690V; cos ϕ = 0,35
A
480
1000
1600
2000
at ...220V; L/R
A
240
375
600
950
Short-time withstand current 1s
kAeff
15
27
32
38
Short-circuit rating with protection by means of fuses
kAeff
120
120
120
120
kÂ
24
36
48
70
= 15ms
Short-circuit making capacity with solid links (peak value)
Mechanical lifespan (operations)
DIN FUSE DISCONNECTS – HORIZONTAL
Permissable ambient temperature
>1000
°C
-25 bis + 55
Climatic proofing
DIN 50016 FW24 (23°C/83% - 40°C/92%)
DIN 50017 SFW - 30 cycles
DIN 50018 SFW 0,2 S - 2 cycles
Shock-proof for use on railways according to VDE 0115
2g / 5g
Altitude (without restriction)
3000m
Seismic withstand capability to DIN 40046/8
0,8g / 16 Hz - 35 Hz
Rated heat dissipation of contacts
3x2.3W
22
3x4.3W
3x9.0W
3x17.3W
Type
A
B
C
D
E
F
R
G
L
N
O
S
DIND003
105.5
149
83.5
151
43
25
198
79
120
17
M8
33
DIND013
184
230
113
220
64
43.75
295
114
177
24.5
M10
58
DIND023
210
256
127
244
78.5
69.75
332
128
205
24.5
M10
66
DIND033
254
270
142
244
93.5
80
345
135
219.5
30.5
M10
82
* Dimension C1: 132mm with electronic fuse monitoring device fitted
Fixing Dimensions
Size 00
Size 1
Size 2
23
Size 3
DIN FUSE DISCONNECTS – HORIZONTAL
Dimensions
DIN Disconnects (vertical)
Strip Fuseaways sizes 1 - 3
for Flush and Surface Mounting
by JEAN MÜLLER
NH Load-disconnect strip fuseaways DIN sizes 1 – 3 for flush and surface mounting.
3-pole switchable
1-pole switchable
DIN Size
Rated Current
Type
Weight kg
DIN Size
Rated Current
Type
Weight kg
1
250
SL1-3x
5,8
1
250
SL1-3x3
5,8
2
400
SL2-3x
6,1
2
400
SL2-3x3
6,1
3
630
SL3-3x
6,8
3
630
SL3-3x3
7,5
Specials available on request (sizes 00/160A - 4/1250A & 1800A size 3 isolators, pictured)
Connection possibilities
Screw Connection
Standard design
Size1: M10
Size 2 and 3: M12
New Delta Contact
■
■
■
■
■
4 separately spring loaded contact lines for
low contact resistances.
50% greater surface area for low contact
temperatures.
Optimum arc control while switching loads.
Connection to short circuit (50kA) possible without
switching aids.
High dynamic strength during switching operations.
Special strip features
■
■
DIN FUSE DISCONNECTS – VERTICAL
■
■
■
■
■
■
■
■
Suitable for busbar mounting with 185mm spacing between busbar centres.
Cable connection at the top or bottom can be achieved by simply turning
the base moulding of the contacts upside down, while the panel aperture
remains unchanged.
Removable fuse carrier allows easy mounting.
Equal mounting conditions allow combination with size 00 strip fuseaways.
Complete protection against electric shock in on- and off-position in
accordance with German accident prevention legislation (VBG4).
Connection of conductors by means of cable lugs or direct connecting terminals.
The hinged cover holding the fuse-link is “parked” in the off-position – this means
visible disconnection.
Latch-in elements for fixing to the panel.
All 3 phases of the 3-pole switchable strip fusaways are switched simultaneously.
Hinged cover of 3-pole switchable version can be barred and locked.
24
DIN Disconnects (vertical) Dimensions
Accessories
Hinged cover for test purposes
Suitable for insertion of K-series metering fuses
Hinged cover for earthing purposes
1
1
Size 1
Size 2
Size 3
MS-SL1
MS-SL2
MS-SL3
E-SL123
Hinged cover for piggy-back fuse-links
HP-SL123
Extended shroud in the connection area
HA-SL123
(suitable for sizes 1, 2 and 3)
only for SL1, 2 and 3x3
Dimensions
195
99.5
SL... -3x/...
1-pol. switching
24
Rest Position: ~335
30
52
50
154
303
Operating position ~467
SL... -3x3/...
3-pol. switching
25
Sliding
Distance
DIN FUSE DISCONNECTS – VERTICAL
14
150
14x32
185
662
14
185
8.5x16
185
100
195
DIN Disconnects (vertical)
Technical Data
NH Load-disconnect Strip Fuseaways for Flush and Surface Mounting
DIN
Size 1
Size 2
Size 3
Rated current
A
250
400
630
Uninterrupted
A
325
520
820
Uninterrupted current with solid links
A
290
460
725
Rated voltage
-V
660
660
660
Rated frequency
Hz
40 - 60
Test voltage
V
2500
Insulation class to VDE 0110
C
which corresponds to degree 3 contamination
in accordance with VDE 0109
Rated making - and breaking capacity to VDE 0660 Part 107
at 400V; cos = 0,35
A
2500
3800
3800
at 500V; cos = 0,35
A
1500
2400
3200
at 690V; cos = 0,35
A
1000
1600
2000
375
600
950
at —220V; L/R = 15ms
Rated short-time with withstand current 1 sec.
kA
20
22
25
Short-circuit protection by fuses (current-carrying capacity)
kA
120
120
120
Rated conditional short-circuit current with protection by fuses
kA
50
50
50
Rated conditional short-circuit current with solid links and protection
by fuses (peak value) 500 V; lp = 120 kA
kA
36
48
70
Rated short-circuit making capacity with NH fuse-links
kA
105
105
105
Heat dissipation of main current path
W
23
49
110
Mechanical lifespan (operations)
>1000
°C
Permissable ambient temperature
Climatic proofing
-25 to + 55
DIN 50016 FW* 24 (23°C/83% – 40°C/92%)
DIN 50017 SFW** 30 cycles
DIN 50018 SFW 0.25; 2 cycles
DIN FUSE DISCONNECTS – VERTICAL
Shockproof for railway systems to VDE 0115
2g / 5g
Altitude above sea level (without restriction)
3000m
Resistant to earthquakes in accordance with DIN 40046/8
0.8g / 16 Hz - 35 Hz
Tested to VDE 0660 Part 107, VDE 0636 Part 21
* Damp alternating atmosphere
** Damp heat alternating atmosphere
26
Series 7 Insulated House Service Cutouts
■
■
■
■
■
■
■
■
■
■
Thermoplastic moulding giving improved mechanical strength and durability.
Easy fuse replacement – fuse link self locating in fuse clip.
High pressure point contacts – wiping action ensures low resistance with silver
plated base contacts.
Carrier assembled by means of captive screw.
Base moulding in one-piece, increased mechanical strength – eliminates tracking.
All phase terminals shrouded by fixed shield which is part of moulding.
Plain brass terminals with silver plated contact surface for dependable operation.
Tin plated fuse clips.
Suitable for cable conductors 2.5 sq.mm to 50 sq.mm.
Anti-intrusion plate with double hole sealing facility, 100% tamperproof,
allows base to be sealed independently of the handle.
27
SERIES 7 FUSE HOLDERS
General Features
Series 7
Type Numbers
Type No.
Rating Amps
S71002AFWS
Front Wire Fittings
Back Wire Fittings
Fuse Link
100
Type 2a, RHF30-100
S71002BFW
100
Type 2b, RHLF60-100
S71002BFWAI
100
Type 2b, RHLF60-100
S71002ABWS
100
Type 2a, RHF30-100
S71002BBW
100
Type 2b, RHLF60-100
S71002BBWAI
100
Type 2b, RHLF60-100
AI suffix = fitting fitted with anti-intrusion plate
Dimensions
Front Wire & Back Wire
Base
■
Cable entry holes (backwire)
83mm
88mm
47mm
42mm
SERIES 7 FUSE HOLDERS
88mm
66mm
Single Hole Fixing
Rear View
(1 x 6.35mm diameter hole)
28
RSL63
Features and Benefits
■
■
■
■
■
Fully Shrouded – Ensures complete personnel safety against live metal contact.
Insulated Terminal Shrouds – Are fitted to front connected fuse bases to
provide increased protection at the cable entry point.
Insulated Base Contacts Shrouds – Enables an outgoing circuit to be cabled
with complete safety to personnel and with continuity of supply to other circuits.
Large Contact Area – Solid brass contacts ensure lasting contact pressure.
Patented Non-twist Cable Clamping Screws – Ensures cable strands are
firmly clamped into position without damaging the cable strands.
Selection Table
TYPE
CONNECTION
VOLTAGE AC
VOLTAGE DC
RSL63H
Front
1200
750
RSL 63PH
Front/Rear Stud
1200
750
RSL 63P
Rear Stud
1200
750
ASSOCIATED T-C HRC FUSE LINK
TAC 2, 4, 6, 10, 15, 20, 25 & 30
TSC 35, 50 & 63
Applications
RSL FUSE HOLDERS
Short circuit and overload protection when used with T-C HRC fuse links.
■ 1000VAC heating and lighting circuits (mining).
■ Capacitor circuits.
■ A.C. and D.C. motor circuits.
■ Cable overload protection. T-C fuses with minimum fusing currents of
1.5-1-6In will protect cables (PVC insulated copper) when the fuse fitted is
equal to or less than the cable rating.
■ Short circuit cable protection offered to PVC insulated copper cables
i.e. I2t=K2S2, where I = current which causes fuse to operate in 5 seconds,
t = 5 seconds, K = 115, S = conductor cross sectional area in mm2.
29
Dimensions
RSL FUSE HOLDERS
30
Fuse Link Selection Chart
Current Rating (A)
2-32
40-63
2-20
2-32
35-63
2-63
2-63
80 & 100
80 & 100
125 & 160
80 & 100
125-200
250 & 315
250 & 315
355 & 400
450-630
670-800
5-20
25-75
25-75
16-63
NS
ES
NIT & NITL
TIA & TIAL
TIS & TISL
TB
TBC
OS
TCP & TCPL
TFP
TC & TCL
TF
TKF & TKFL
TKM
TM & TML
TTM & TTML
TLM & TLML
GSA
GSA
GSB
GSGB
20
●
32
●
63
H
F
G
G
●
Fuse Switches
CM, CMP, CMS, CMSE
Red Spot Miniature
Fuse Fittings
Red Spot
20
“A”
“B”
“C”
“E”
“F”
–
–
–
–
–
●
32
●
63
●
●
100
A
A
E
●
200
●
●
●
400
B
B
B
●
●
●
400
B
B
630
B
800
B
32
●
●
B
B
●
●
B
B
B
●
●
●
B
B
B
●
●
●
●
63
●
●J
100
●
●
160
A
A
100
C
C
200
C
C
Use AA Adaptor
Use BA Adaptor
Use CA Adaptor
Use GSA-1 Adaptor
Use GSA-2 Adaptor
B
●
K
L
●
●
“G”
“H”
“J”
“K”
“L”
●
●
–
–
–
–
–
Use GSB-2 Adaptor
Use SCA63 Carrier
Except TIS63M80-63M100
Except OS100M125
Max Assisted Start Motor = 45kW
31
●
RSL FUSE HOLDERS
Safeclip
Class of Gear
Type of Equipment
Type Number Prefix Letters & Current Range
7671 TAN 04/02
INDUSTRIAL PRODUCTS
25 Princes Road Regents Park NSW 2143
Tel: 1300 556 601 Fax: 1300 550 187 www.ip.alstom.com.au