Fuse Holders, Bases & Disconnects Contents RSM Fuse Holders & Accessories Red Spot Fuse Holders & Accessories Safeclip Fuse Holders & Accessories Modular Fuse Holders DIN Fuse Bases & Accessories DIN Fuse Disconnects – Horizontal DIN Fuse Disconnects – Vertical Series 7 Fuse Holders RSL Fuse Holders 2 ■ ■ ■ ■ ■ ■ World leading Red Spot quality at the right price Smallest BS88 bolt-in fuse holders available Silver plated as standard Fully shrouded for personal safety Insulating sleeves supplied with front wired versions for extra protection Suitable as current limiters when fitted with fuse links RSM Red Spot Fuse Holders Rating A Type Colour Connection Recommended max. cable size Associated fuse link 32A RSM32H Black Front wired 10mm2 NIT2-32 (415V, 550V) 63A RSM63H Black Front wired 25mm2 TIA / TIS 2 100A RSM100H Black Front wired 50mm TIS / OS 160A RSM160H Black Front wired 95mm2 TCP / TFP Accessories Pad-lockable Inserts RS20LOCK Suits RSM32 RS32LOCK Suits RSM63 RS63LOCK Suits RSM100 RS100LOCK Suits RSM160 DIN Rail Adaptor RS20A Suits RSM32 White Fuse Fittings (to match size of RSM black fuse fittings) Type Associated Black Fuse Fitting Copper Link Type Number RS20HWH RSM32H RS20CLINK RS32HWH RSM63H RS32CLINK RS63HWH RSM100H RS63CLINK Copper Link Ratings RS20CLINK=32A RS32CLINK=63A 3 RS63CLINK=100A RS100CLINK=200A RSM FUSE HOLDERS & ACCESSORIES Red Spot Miniature Fuse Holders Panel Drilling Dimensions (viewed from front of panel) RSM FUSE HOLDERS & ACCESSORIES 32A 63A 100A 160A RSM32H RSM63H RSM100H RSM160H mm N P U V 6.4 3.2 9.5 11.1 RSM Dimensions 32, 63, 100 & 160 amp Front Connected Rating Amp A B C H J X Y Z 32 27 29 55 15 16 60 6.6 37 mm 63 32 103 70 15 22 7.0 5.6 49 mm 100 35 110 75 15 24 9.5 5.6 54 mm 160 51 140 100 15 28 14 7.2 74 mm 4 Red Spot Fuse Fittings ■ ■ ■ ■ Fuse fittings to AS2005.21.2 – 1990, BS88: Part 2: 1988, 660 volts AC/DC. Approved by leading authorities and used in equipment approved by Lloyds. Full Shrouding for personnel safety and complete compliance with the direct contact electric shock requirements. Insulating sleeves are fitted to front connected fuse bases to provide increased protection at the cable entry point. Separate base contact insulating shrouds of great strength and flexibility ensure that no “live” metal is dangerously exposed when the fuse carrier is removed. Anti-vibration features protect against release of a fuse-carrier due to vibration in service. In the 400 amp size this includes a safety catch which automatically locks on the insertion of the fuse carrier. Type Numbers Alternative type of connection Rating amp Front Back Front/Back Back Wired 20 RS20H* RS20P RS20PH RS20BW 32 RS32H RS32P RS32PH RS32BW 63 RS63H RS63P RS63PH RS63BW 100 RS100H RS100P RS100PH RS100BW 200 RS200H RS200P RS200PH 400 RS400H RS400P Illustrations & dimensions shown on pages 8-11 Recommended Maximum Cable Sizes Rating amp BW types 10mm 2 10mm2 25mm 2 16mm2 63 50mm2 35mm2 100 95mm2 70mm2 20 32 Cut-away view of 63 amp front connected contact assembly H and PH types 200 400 2 – 2 – 120mm 240mm 5 RS400PH * For Din Rail Mounting order DIN Rail Adaptor Part No: RS20A REDSPOT FUSE HOLDERS & ACCESSORIES Safety Features Application Data HRC Fuse Links Accomodated Extended range of Type ‘T’ to BS.88:Part 2: AS2005.21.2 for motor circuit protection (660V AC) Fuse Fitting Rating Amp Type ‘T’ to BS.88:Part 2 & AS2005.21.2 List No. REDSPOT FUSE HOLDERS & ACCESSORIES Current Rating Amp Rating for Motor Starting Amp 20 20 25 32 32 32 32 32 35 40 50 63 TIS63M80 TIS63M100 63 63 80 100 TIA2L-32L† TIS35L-63L† TCP80L&100L TCP100M125 TCP100M160 TCP100M200 100 100 100 125 160 200 TBC2-63A TC80 & 100A TF125-200A TC80L & 100L TF125L-200L TF200M250 TF200M315 200 200 250 315 TBC2-63A# TC80 & 100# TF125-200# TKF250 & 315# TKM250 & 315A TM355 & 400A TC80L & 100L# TKF250L&315L# TM355L&400L TM400M450 400 450 550/660V 415V AC 550/660V 20 NIT2-20A (550 volts a.c.) NIT2L-20L NIT20M25 NIT20M32 (415 volts a.c.) 32 TIA2-32A TIA2L-32L TIA32M35 TIA32M50 TIA32M50 TIA32M63 63 TIA2-32A TIS35-63A TIA2L-32L TIS35L-63L 100 TIA2-32A† TIS35-63A† TCP80 & 100A 200 400 † Adaptor plate required Type ‘A’ 5BB9306-010 415V AC TIA32M35L TIA32M40L TIA32M50L TIA32M63L # Adaptor plate required Type ‘B’ 5BB9307-010 Method of Cabling Front connected 63 amp fuse fitting Front connected fuse fittings 1. Remove red nylon insulating shroud to release cable sleeve. 2. Remove cable sleeve. 3. Fit cable sleeve over cable. 4. Fit conductor into fuse base terminal and tighten cable clamping screw to secure. If flexible cables are used, their relatively fine strands may be given increased protection by the use of thin wall copper ferrules over the conductor. The following should be taken into account: a) The inside diameter of the thin wall copper ferrule should match that of the bared conductor end as closely as possible. b) The length of the thin wall copper ferrule should match that of the tunnel in the fuse base terminal. c) The wall thickness of the ferrule should be thin enough for the ferrule to be compressed by the tightening of the cable clamping screw. The flexible conductors will then be consolidated within the deformed ferrule. 5. Replace red nylon shroud taking care that it holds the cable sleeve in position by locating the shroud in the groove in the sleeves. 6 Dimensions 20A Red Spot Fuse Fittings Front/Back Connected Back Connected – Surface REDSPOT FUSE HOLDERS & ACCESSORIES Front Connected mm A B C1 C2 D E F G H J K L X Y Y2 Z 27.0 79.0 54.0 55.0 63 58.8 M6 13.5 15.0 16 10.10 29 6.0 5.6 6.6 37 Panel Drilling Dimensions (viewed from front of panel) 7 Dimensions 32, 63 & 100 amp Red Spot Fuse Fittings Front Connected Front/Back Connected Back Connected – Surface REDSPOT FUSE HOLDERS & ACCESSORIES Rating Amp A B C D E F G H J K L X Y Z 32 32 103 70 81.0 73 M6 17.5 15 22 15 29 6.2 5.6 49 mm 63 35 110 75 84.0 78 M8 17.5 15 24 16 29 9.5 5.6 54 mm 100 51 140 100 87 94 M10 22 15 28 23 32 14 7.2 74 mm Panel Drilling Dimensions (viewed from front of panel) mm N P Q R S T U V W 6.4 3.2 36.5 41.3 52.4 51.6 9.5 11.1 46.8 8 Dimensions 200 amp Red Spot Fuse Fittings Front/Back Connected Back Connected – Surface REDSPOT FUSE HOLDERS & ACCESSORIES Front Connected 400 amp Red Spot Fuse Fittings Rating Amp A B C 200 400 D E F G H 70 216 98 254.0 J K L M X Y 136.5 95 171.5 M12 25 192 114 140 M16 32 Z 22 32 22 32 100.0 16 9.5 84 mm 32 36.5 57 38 151 21 32 130 mm Panel Drilling Dimensions (viewed from front of panel) RS400H RS200H RS400P & RS400PH RS200P & RS200PH N mm 19.1 P Q 28.6 85.7 P 9 mm 27.0 Q 69.9 Dimensions Red Spot Fuse Fittings Back Wired Panel Mounted REDSPOT FUSE HOLDERS & ACCESSORIES Type Rating Amp A RS20BW 20 27 RS32BW 32 32 RS63BW 63 35 RS100BW 100 51 B C D E F G All dimensions in mm 80 54 6 30 30 – 103 70 6 40 40 3.2 110 75 6 40 46 3.2 140 100 7 52.6 52.6 11 10 H J DIA K L X Max. Cable Size mm2 – 8 To suit M5 37 5.3 10 6.4 8 M5 49 5.4 16 6.4 8 M5 54 8.7 35 9.5 16 M6 74 12.7 50 Accessories Padlockable Insert Current Rating Amp Type * 20 RS20Lock 32 RS32Lock 63 RS63Lock 100 RS100Lock • Because of the variety of suitable locks available, and customers individual preferences, these devices are supplied without padlocks. DIN Rail Adaptor RS20A for the RS20 range of fittings Bolted Neutral Links Fitting Type Model 20 RS20CLINK 32 RS32CLINK 63 RS63CLINK 100 RS100CLINK Adaptors to fit Semiconductor Fuse Links into Red Spot Fuse Fittings Type To fit fuses Fuse Fitting GSA-1 GSA5 to GSA20 RS32 GSA-2 GSA25 to GSA75 RS100 GSB-2 GSB25 to GSB75 RS100 GSGB16 to GSGB63 RS100 Adaptors to fit small Fuse Links into larger Red Spot Fuse Fittings Type To fit fuses Fuse Fitting AA TIA, TIS RS100 BA TBC, TC, TF, TKF RS400 11 REDSPOT FUSE HOLDERS & ACCESSORIES When ordering please quote the following number: Safeclip Fuse Fittings Features & Benefits ■ ■ ■ ■ ■ ■ ■ NEW easy to remove fuse carrier. Self cleaning, self aligning base contacts. Fuse carriers moulded from tough flame retardant material. No screws or tools required to fit fuse. Made from flame retardant thermoplastic or phenolic. Integral DIN rail mounting feature. Full shrouding and complete compliance with the direct contact electric shock requirements. SAFECLIP FUSE HOLDERS & ACCESSORIES Rating Amp 20 63 20, 32 & 63A 415/550V AC. Complying fully with AS2005.29 – 1990, BS88 : Part 6 : 1988. Type of Connection List Number Colour Associated HRC Fuse Lines Front SC20H Black, White NS2 – 20 NS20M25 & 32 Front SC32H Black, White Back SC32P Black, White Busbar/Front SC32BH Black Busbar/Front SC32BHA+ Black Back Wired SC32BW Black Front SC63H-D Black, White NS2 – 32* Back SC63P Black ES40, 50 & 63 Busbar/Front SC63BH Black ES63M80 NS2 – 32 NS20M25 & 32 * SCA63NS carrier required Note: All fuse fittings provided with DIN rail facility except: SC32 & 63BH; SC63P + Long stud version Accessories Adaptor carrier for fitting Type NS fuse links into SC63 fuse holder Copper links Rating List Number 32 SCA63NS 20/32 63 Recommended Maximum Cable Sizes Rating amp H and PH types 20 16mm2 – 32 16mm2 16mm2 63 25mm2 – 12 BW types SC20/32LINK ESCLINK SAFECLIP Fuse Fitting Dimensions Front Connected Panel drilling viewed from front of panel 63A 20 & 32A; 63A 20 to 63A 20 to 63A Rating amp A B 20 & 32 26.5 75.5 54 16 4 2 – – 6 M5 63 30 96 58 24 5 6 8 5 8 M5 C D E F G H J K Back Connected Panel drilling viewed from front of panel 32A 63A Rating amp 32 63 13 A B 26.5 75.5 30 96 C D E F G H J K L 54 16 5 40 29 M6 2 M5 14 53 16 5 51 32 M8 5 M5 17 SAFECLIP FUSE HOLDERS & ACCESSORIES 20A & 32A SAFECLIP Fuse Fitting Dimensions Busbar/Front Connected 32 & 63 amp Panel drilling viewed from front of panel SAFECLIP FUSE HOLDERS & ACCESSORIES Rating amp 32 32/A* 63 A B C D E 25 81 47 18 5 1 12 29 6 26.5 75.5 54 16 – 1 40 29 6 20 5 1 12 33 8 6 30 96 * Long stud version Back Wired 32 amp 14 53 F G H J K L M N 2 M5 M5 4 2 M6 M5 2 M6 M5 6 Modular Fuse Holders ■ ■ ■ ■ ■ ■ ■ ■ Available in 32A, 50A & 125A ratings. DIN rail mountable. Made from highly temperature resistant polyamide material. Available with integral neon fuse blown indicators. All models (except FMC) are sealable in the closed position. 50A & 125A versions padlockable “open” for maintenance safety. 50A & 125A versions available with a microswitch for remote indication. Conform to IEC269-2. CMS221 Amp 32 50 List No. Type FMC101 1 Pole, Compact FMC101S 1 Pole, Compact + Indication FMC103 3 Pole CMS141 1 Pole CMS141S 1 Pole + Indication CMS141M 1 Pole + Microswitch Fuse Size Fuse Ratings Type 10 x 38 0.5A - 32A 10G 14 x 58 2A - 50A 14G 22 x 58 4A - 125A 22G CMS141SM 1 Pole + Indication + Microswitch 125 CMS221M CMS221 1 Pole CMS221S 1 Pole + Indication CMS221M 1 Pole + Microswitch CMS221SM 1 Pole + Indication + Microswitch Indication refers to fuse blown indication (neon globe built into fuseholder). Microswitch = 3 pin (NC, NO, C) indicates no fuse, holder open, blown fuse (striker fuses only). Accessories List No. Type FMP3 Connector pin for multi-pole FMC type holders MPOLE14 Multi-pole kit for CMS141 – connects up to 10 poles MPOLE22 Multi-pole kit for CMS221 – connects up to 10 poles FMC101 15 MODULAR FUSE HOLDERS Modular Fuse Holder Holders Technical Features – CMS Rating UN(V) Ulmp (kV) Fuse Current Rating IN(A) 0.25 Maximum Fuse Operating Current (A) gG aM gRC UR 0.25 Recommended Copper Wire SIze (mm2) Torque Maxi N.m. 0.25 0.5 1 2 4 6 8 CMS141 690 8 FMC101S 10 10 10 12 12 12 3.5 16 16 16 2.5 20 20 20 2.5 25 25 20 4 32 32 25 6 40 40 40 30 30 6 50 50 50 38 35 10 MODULAR FUSE HOLDERS 1 1 2 4 6 8 10 12 16 CMS221 690 8 CMS141M CMS221 16 20 20 20 4 25 25 25 6 32 32 42 10 40 40 40 6 50 50 50 10 63 51 63 16 80 64 60 25 74 70 35 100 100 125 100 35 4 Modular Fuse Holders and Fuse Links Cross Section of Typical Modular Fuse Base 1 2 3 4 5 6 Base Contact Slide Handle Fuse-link Bolt Material ■ The fuse holders can be fully rated provided that the fuse link does not exceed the holders rated power acceptance: FMC101 3W power acceptance CMS141 4.7W power acceptance CMS221 9.0W power acceptance ■ De-rating for mounting in close proximity is as follows: ■ Maximum cable size for the fuse holders: 10mm compact holder cable up to 25mm2 14mm holder cable up to 35mm2 22mm holder cable up to 35mm2 ■ MODULAR FUSE HOLDERS Base: Polyamide Handle: Thermal Polyester Self extinguishable Contacts: Silver Plated Protection Index – IP20 Live parts are inaccessible Dimensions (mm) Voltage limits for blown fuse indicator operation: up to 3 poles Derating factor = 1 Neon just glowing 65vac/60vdc between 4-6 poles Derating factor = 0.8 Neon glowing strong 100vac/100vdc between 7-9 poles Derating factor = 0.7 50 Amp above 10 poles Derating factor = 0.6 125 Amp 76.5 17 32 Amp A B 59 78 C D F 78 43 76.5 100.5 45 26.5 107 50.5 103 45 17.5 E 45 35 126.5 50.5 DIN Fuse Bases & Accessories 1 Complies with DIN43620 IEC269-2-1 690VAC 6 2 3 DIN FUSE BASES & ACCESSORIES 1 2 3 4 5 6 Terminal Shields NH Fuse Base Separator Insulating Dividers Fuse Shield DIN Rail Clip (optional) Size 00 1 2 Rating Amp 160 250 400 3 630 4 1250 5 4 No of poles Style Type No 1 OB NH00GBASE 1 FS 3 OB2D K-NH00GSHB Style Legend 3 FS NH003PSHB 1 OB NH1GBASE 1 FS 3 OB2D K-NH1G3PB2D 3 FS K-NH1G3PSHB 1 OB NH2GBASE Size 1 FS 3 OB2D OB FS OB2D K-NH00G3PB2D Open base Fully shrouded IP20 Open base plus 2 dividers K-NH1GSHB Spares and Accessories Dividers Terminal Shrouds Fuse Covers Base Separators DIN Rail Clip K-NH2GSHB 00 NH00GDIV NH00TS NH00FC K-NH2G3PB2D 1 NH1GDIV NH1TS NH1FC NH1SEP NH00DRC NH123DRC 3 FS K-NH2G3PSHB 2 NH1GDIV NH2TS NH1FC NH1SEP NH123DRC 1 OB NH3GBASE 3 NH3GDIV NH3TS NH3FC NH3SEP NH123DRC 1 FS K-NH3GSHB 3 OB2D K-NH3G3PB2D 3 FS K-NH3G3PSHB 1 OB NH4BASE Extractor Handle 18 NH-HANDLE Sizes 000 – 4 NH Base Dimensions Dimensions Size 00 N M Q A B F F D E H G O L I C K P J R B C D 20 117 100 E F G 8 2 14 H J K L M N O P Q R 8 56 52 85 84 34 1 104 N A Dimensions Sizes 1, 2, 3 & 4 I 25 145 21,5 DIN FUSE BASES & ACCESSORIES A 32 P B G I C D H O L E K F Q J M R S A B NH1- 60 32 209 176 10,5 30 20,5 25 C D E 250 35 M10 81 71 122,5 146 65,5 125,5 191 256,5 NH2- 60 35 225 201 10,5 30 20,5 25 250 35 M10 81 89 122,5 146 65,5 125,5 191 256,5 NH3- 60 40 241 210 10,5 30 20,5 25 270 35 M12 81 103 142,5 146 81,5 141,5 223 304,5 NH4- 80 45 312 262 11 F 45 G – H 30 19 I – J K L M 45 M16 111 145 N – O 192 P – Q – R – S – DIN Disconnects (horizontal) DIN Fuse Switch-Disconnectors 690V IEC 947-3 ■ ■ ■ ■ ■ ■ Type Rating Poles EN 60947 Sizes 00 and 1 can be interlocked and sealed. Single pole versions available. DIN fuse switch-disconnectors for 1250 A and 1600 A available in single pole and three pole versions for size 4a fuse links (800 – 1600A). Details on request. Type DIND00BB (00/160A) for direct mounting on 60mm busbar systems. Optimal protection against accidental contact and over reaching. High short-circuit making capacity and rated breaking capacity provided by semi-independent manual operation of contacts. Connection DIN FUSE DISCONNECTS – HORIZONTAL DIND003S 160 A 3 STUD DIND00BB 160 A 3 BUSBAR/STUD DIND013S 250 A 3 STUD DIND023S 400 A 3 STUD DIND033S 630 A 3 STUD 1 Protection against overreaching at the top (GO) prevents accidental contact with the upper terminal area. 2 Multifunctional front cover. 3 Optional interlocking and sealing facility. 4 Empty space for company logo. 5 Empty space, e.g. for labelling of circuits. 6 Lock slide for test holes. 7 Test holes to contact blades. 8 Disconnector casing with universal connection. 9 Protection against overreaching at the bottom (GU) prevents accidental contact with the upper terminal area. VDE 0660 10 Divided shrouding with integrated protection against overreaching. 11 Busbar adapter for 60mm busbar system. 20 Accessories for DIN Disconnectors Series 9 Busbar Adaptors For 60mm busbar system. Sizes 1 & 2 Line and Load Shroud Sets Cable Clamp Sets Type 1 BBA01 2 BBA02 Require Clamps Size 00 1 2 Electronic Fuse Monitoring Device: EMDS42TA1 Side Type Top GO-LTL00-3 Bottom GU-LTL00-3 Top GO-LTL1-3 Bottom GU-LTL1-3 Top GO-LTL2-3 Bottom GU-LTL2-3 For Disconnector Size Type Terminal Range Min. - Max. mm 00 CLAMP00 1.5 - 70 * 1 CLAMP1 25 - 150 * 2 CLAMP2 25 - 240 * * Clamp Terminals for Copper and Aluminium Conductors DIN FUSE DISCONNECTS – HORIZONTAL Size Direct Busbar Mounting 160A Disconnector Type DIND00BB (00/160A) for direct mounting on 60mm busbar systems. To fit: 60mm busbar systems (centre to centre) 30mm wide busbar 5-10mm thick busbar 21 Technical Data NH Fuse Switch-Disconnector Series 9 Size 00 Size 1 Size 2 Size 3 Rated operational current le A 160 250 400 630 Thermal current with solid links A 210 325 520 820 Thermal current with fuse-links A 185 290 460 725 Rated voltage Ue V 690 690 690 690 Rated insulation voltage Ui V 750 750 750 750 Rated frequency Hz 40 – 60 Test voltage kVeff 8 400 630 Maximum DIN NH gG fuse link rating A 160 250 Maximum DIN semiconductor fuse rating Call ALSTOM for advice Insulation group ll to VDE 0110 CTI 400 - 600 Rated making and breaking capacity at ~400V; cos ϕ = 0,35 A 1250 2500 3800 3800 at ~500V; cos ϕ = 0,35 A 800 1500 2400 3800 at ~690V; cos ϕ = 0,35 A 480 1000 1600 2000 at ...220V; L/R A 240 375 600 950 Short-time withstand current 1s kAeff 15 27 32 38 Short-circuit rating with protection by means of fuses kAeff 120 120 120 120 k 24 36 48 70 = 15ms Short-circuit making capacity with solid links (peak value) Mechanical lifespan (operations) DIN FUSE DISCONNECTS – HORIZONTAL Permissable ambient temperature >1000 °C -25 bis + 55 Climatic proofing DIN 50016 FW24 (23°C/83% - 40°C/92%) DIN 50017 SFW - 30 cycles DIN 50018 SFW 0,2 S - 2 cycles Shock-proof for use on railways according to VDE 0115 2g / 5g Altitude (without restriction) 3000m Seismic withstand capability to DIN 40046/8 0,8g / 16 Hz - 35 Hz Rated heat dissipation of contacts 3x2.3W 22 3x4.3W 3x9.0W 3x17.3W Type A B C D E F R G L N O S DIND003 105.5 149 83.5 151 43 25 198 79 120 17 M8 33 DIND013 184 230 113 220 64 43.75 295 114 177 24.5 M10 58 DIND023 210 256 127 244 78.5 69.75 332 128 205 24.5 M10 66 DIND033 254 270 142 244 93.5 80 345 135 219.5 30.5 M10 82 * Dimension C1: 132mm with electronic fuse monitoring device fitted Fixing Dimensions Size 00 Size 1 Size 2 23 Size 3 DIN FUSE DISCONNECTS – HORIZONTAL Dimensions DIN Disconnects (vertical) Strip Fuseaways sizes 1 - 3 for Flush and Surface Mounting by JEAN MÜLLER NH Load-disconnect strip fuseaways DIN sizes 1 – 3 for flush and surface mounting. 3-pole switchable 1-pole switchable DIN Size Rated Current Type Weight kg DIN Size Rated Current Type Weight kg 1 250 SL1-3x 5,8 1 250 SL1-3x3 5,8 2 400 SL2-3x 6,1 2 400 SL2-3x3 6,1 3 630 SL3-3x 6,8 3 630 SL3-3x3 7,5 Specials available on request (sizes 00/160A - 4/1250A & 1800A size 3 isolators, pictured) Connection possibilities Screw Connection Standard design Size1: M10 Size 2 and 3: M12 New Delta Contact ■ ■ ■ ■ ■ 4 separately spring loaded contact lines for low contact resistances. 50% greater surface area for low contact temperatures. Optimum arc control while switching loads. Connection to short circuit (50kA) possible without switching aids. High dynamic strength during switching operations. Special strip features ■ ■ DIN FUSE DISCONNECTS – VERTICAL ■ ■ ■ ■ ■ ■ ■ ■ Suitable for busbar mounting with 185mm spacing between busbar centres. Cable connection at the top or bottom can be achieved by simply turning the base moulding of the contacts upside down, while the panel aperture remains unchanged. Removable fuse carrier allows easy mounting. Equal mounting conditions allow combination with size 00 strip fuseaways. Complete protection against electric shock in on- and off-position in accordance with German accident prevention legislation (VBG4). Connection of conductors by means of cable lugs or direct connecting terminals. The hinged cover holding the fuse-link is “parked” in the off-position – this means visible disconnection. Latch-in elements for fixing to the panel. All 3 phases of the 3-pole switchable strip fusaways are switched simultaneously. Hinged cover of 3-pole switchable version can be barred and locked. 24 DIN Disconnects (vertical) Dimensions Accessories Hinged cover for test purposes Suitable for insertion of K-series metering fuses Hinged cover for earthing purposes 1 1 Size 1 Size 2 Size 3 MS-SL1 MS-SL2 MS-SL3 E-SL123 Hinged cover for piggy-back fuse-links HP-SL123 Extended shroud in the connection area HA-SL123 (suitable for sizes 1, 2 and 3) only for SL1, 2 and 3x3 Dimensions 195 99.5 SL... -3x/... 1-pol. switching 24 Rest Position: ~335 30 52 50 154 303 Operating position ~467 SL... -3x3/... 3-pol. switching 25 Sliding Distance DIN FUSE DISCONNECTS – VERTICAL 14 150 14x32 185 662 14 185 8.5x16 185 100 195 DIN Disconnects (vertical) Technical Data NH Load-disconnect Strip Fuseaways for Flush and Surface Mounting DIN Size 1 Size 2 Size 3 Rated current A 250 400 630 Uninterrupted A 325 520 820 Uninterrupted current with solid links A 290 460 725 Rated voltage -V 660 660 660 Rated frequency Hz 40 - 60 Test voltage V 2500 Insulation class to VDE 0110 C which corresponds to degree 3 contamination in accordance with VDE 0109 Rated making - and breaking capacity to VDE 0660 Part 107 at 400V; cos = 0,35 A 2500 3800 3800 at 500V; cos = 0,35 A 1500 2400 3200 at 690V; cos = 0,35 A 1000 1600 2000 375 600 950 at —220V; L/R = 15ms Rated short-time with withstand current 1 sec. kA 20 22 25 Short-circuit protection by fuses (current-carrying capacity) kA 120 120 120 Rated conditional short-circuit current with protection by fuses kA 50 50 50 Rated conditional short-circuit current with solid links and protection by fuses (peak value) 500 V; lp = 120 kA kA 36 48 70 Rated short-circuit making capacity with NH fuse-links kA 105 105 105 Heat dissipation of main current path W 23 49 110 Mechanical lifespan (operations) >1000 °C Permissable ambient temperature Climatic proofing -25 to + 55 DIN 50016 FW* 24 (23°C/83% – 40°C/92%) DIN 50017 SFW** 30 cycles DIN 50018 SFW 0.25; 2 cycles DIN FUSE DISCONNECTS – VERTICAL Shockproof for railway systems to VDE 0115 2g / 5g Altitude above sea level (without restriction) 3000m Resistant to earthquakes in accordance with DIN 40046/8 0.8g / 16 Hz - 35 Hz Tested to VDE 0660 Part 107, VDE 0636 Part 21 * Damp alternating atmosphere ** Damp heat alternating atmosphere 26 Series 7 Insulated House Service Cutouts ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Thermoplastic moulding giving improved mechanical strength and durability. Easy fuse replacement – fuse link self locating in fuse clip. High pressure point contacts – wiping action ensures low resistance with silver plated base contacts. Carrier assembled by means of captive screw. Base moulding in one-piece, increased mechanical strength – eliminates tracking. All phase terminals shrouded by fixed shield which is part of moulding. Plain brass terminals with silver plated contact surface for dependable operation. Tin plated fuse clips. Suitable for cable conductors 2.5 sq.mm to 50 sq.mm. Anti-intrusion plate with double hole sealing facility, 100% tamperproof, allows base to be sealed independently of the handle. 27 SERIES 7 FUSE HOLDERS General Features Series 7 Type Numbers Type No. Rating Amps S71002AFWS Front Wire Fittings Back Wire Fittings Fuse Link 100 Type 2a, RHF30-100 S71002BFW 100 Type 2b, RHLF60-100 S71002BFWAI 100 Type 2b, RHLF60-100 S71002ABWS 100 Type 2a, RHF30-100 S71002BBW 100 Type 2b, RHLF60-100 S71002BBWAI 100 Type 2b, RHLF60-100 AI suffix = fitting fitted with anti-intrusion plate Dimensions Front Wire & Back Wire Base ■ Cable entry holes (backwire) 83mm 88mm 47mm 42mm SERIES 7 FUSE HOLDERS 88mm 66mm Single Hole Fixing Rear View (1 x 6.35mm diameter hole) 28 RSL63 Features and Benefits ■ ■ ■ ■ ■ Fully Shrouded – Ensures complete personnel safety against live metal contact. Insulated Terminal Shrouds – Are fitted to front connected fuse bases to provide increased protection at the cable entry point. Insulated Base Contacts Shrouds – Enables an outgoing circuit to be cabled with complete safety to personnel and with continuity of supply to other circuits. Large Contact Area – Solid brass contacts ensure lasting contact pressure. Patented Non-twist Cable Clamping Screws – Ensures cable strands are firmly clamped into position without damaging the cable strands. Selection Table TYPE CONNECTION VOLTAGE AC VOLTAGE DC RSL63H Front 1200 750 RSL 63PH Front/Rear Stud 1200 750 RSL 63P Rear Stud 1200 750 ASSOCIATED T-C HRC FUSE LINK TAC 2, 4, 6, 10, 15, 20, 25 & 30 TSC 35, 50 & 63 Applications RSL FUSE HOLDERS Short circuit and overload protection when used with T-C HRC fuse links. ■ 1000VAC heating and lighting circuits (mining). ■ Capacitor circuits. ■ A.C. and D.C. motor circuits. ■ Cable overload protection. T-C fuses with minimum fusing currents of 1.5-1-6In will protect cables (PVC insulated copper) when the fuse fitted is equal to or less than the cable rating. ■ Short circuit cable protection offered to PVC insulated copper cables i.e. I2t=K2S2, where I = current which causes fuse to operate in 5 seconds, t = 5 seconds, K = 115, S = conductor cross sectional area in mm2. 29 Dimensions RSL FUSE HOLDERS 30 Fuse Link Selection Chart Current Rating (A) 2-32 40-63 2-20 2-32 35-63 2-63 2-63 80 & 100 80 & 100 125 & 160 80 & 100 125-200 250 & 315 250 & 315 355 & 400 450-630 670-800 5-20 25-75 25-75 16-63 NS ES NIT & NITL TIA & TIAL TIS & TISL TB TBC OS TCP & TCPL TFP TC & TCL TF TKF & TKFL TKM TM & TML TTM & TTML TLM & TLML GSA GSA GSB GSGB 20 ● 32 ● 63 H F G G ● Fuse Switches CM, CMP, CMS, CMSE Red Spot Miniature Fuse Fittings Red Spot 20 “A” “B” “C” “E” “F” – – – – – ● 32 ● 63 ● ● 100 A A E ● 200 ● ● ● 400 B B B ● ● ● 400 B B 630 B 800 B 32 ● ● B B ● ● B B B ● ● ● B B B ● ● ● ● 63 ● ●J 100 ● ● 160 A A 100 C C 200 C C Use AA Adaptor Use BA Adaptor Use CA Adaptor Use GSA-1 Adaptor Use GSA-2 Adaptor B ● K L ● ● “G” “H” “J” “K” “L” ● ● – – – – – Use GSB-2 Adaptor Use SCA63 Carrier Except TIS63M80-63M100 Except OS100M125 Max Assisted Start Motor = 45kW 31 ● RSL FUSE HOLDERS Safeclip Class of Gear Type of Equipment Type Number Prefix Letters & Current Range 7671 TAN 04/02 INDUSTRIAL PRODUCTS 25 Princes Road Regents Park NSW 2143 Tel: 1300 556 601 Fax: 1300 550 187 www.ip.alstom.com.au