High-Performance Passive Devices

advertisement
High-Performance
Passive Devices
In the battle against passive intermodulation (PIM),
CommScope unveils a new standard for passive components.
Table of Contents
Introduction
Why permit a preventable weakness in your network?.......................................................4
What is PIM and what causes it?.....................................................................................4
All about PIM and our experiences
High-performance active components are also highly susceptible to PIM...............................5
Deploy proactive, proven protection against PIM...............................................................6
PIM products in detail
Part number description..................................................................................................7
Air Directional Couplers.................................................................................................8
Attenuators...................................................................................................................10
Coaxial Loads / Terminations..........................................................................................12
Tappers........................................................................................................................14
Hybrid Couplers............................................................................................................16
High Power Splitters.......................................................................................................17
CMAX SISO and MIMO Antennas...................................................................................18
2
For more information, visit commscope.com
Why permit a preventable
weakness in your network?
To streamline the modernization of your LTE network,
you invested a tremendous amount of time, energy,
resources and expertise into a variety of active
components. Imagine commissioning your new
hardware, only to discover a massive, network-wide
spike in PIM caused by your Achilles heel:
low-quality passive components.
Subscribers want it all
Recent wireless usage statistics prove that today’s subscribers
expect “five bars” of signal strength and instant data speeds—
everywhere, all the time:
100%
4G LTE networks
- and the sophisticated
distributed antenna systems (DAS) supporting them—represent
MORE. More capacity. More frequency bands. More
data traffic. More powerful technology. More effective
performance. More revenue potential.
2011
2012
2013
2014
2015
2016
80%
41%
40%
2017
66%
60%
20%
0%
But the modern 4G LTE network is also far
more complex than its predecessors. Capacity
requirements are doubling every year, requiring
higher carrier counts and more efficient modulations
schemes. These challenges introduce a greater
probability of PIM interference—and that can cause
major deployment headaches for you.
TRAFFIC VIA MOBILE DEVICES
6%
2012
2013
80% GROWTH
~ in data traffic across ~
WORLDWIDE WIRELESS NETWORKS
BETWEEN 2012 AND 2013
Source: “Cisco Visual Networking Index: Global Mobile Data
Traffic Forecast Update, 2013–2018”, Feb. 5, 2014
What is PIM and what causes it?
In a passive non-linear radio frequency (RF) circuit, PIM is the interaction of fundamental signal frequencies that produces
extra unwanted signals. These unwanted signals inadvertently produce many signals at other frequencies. These
frequencies, called harmonics (integer multiples), are what cause signal interference.
From an antenna performance perspective,
PIM typically occurs when:
From a design, deployment and usage perspective,
PIM is typically caused by:
• PIM products fail in the receiver band
• Surface oxidation in the RF path
• Two or more transmitter channels share
a common antenna
• Improperly torqued connectors
• Transmitter signal levels are high
• Insufficient metal plating
• Transmitters and receivers are duplexed
• Poor solder connections and splatters
• Contact between dissimilar metals as a
result of insufficient plating of metal
• Structures or objects close to the cell site
• Improperly torqued connectors
• Structures or objects in close proximity to the site
• Loose metal-to-metal contacts
• Nearby ferromagnetic materials
• Component vibration
For more information, visit commscope.com
3
High-performance active components
are also highly susceptible to PIM
Over the years, PIM has evolved from a virtually unknown DAS performance metric into
a critical system requirement. Network performance, as identified by download speed,
is highly susceptible to smaller levels of distortion that significantly impact performance.
Hyper-sensitive antennas and radios, multiple frequency overlays and more components in
the RF path create an environment where the margin for error for PIM continues to shrink.
Download speeds are critical in DAS environments like stadiums, where many components
in the RF path can generate PIM. Splitters, hybrid couplers, directional couplers and
tappers are being installed closer to active signal sources. To accommodate this closer
proximity, minimum PIM specifications for these signal distribution components continue to
rise.
As a result, our suite of -160 dBc (-117 dBm) passive devices represents the
high-performance innovation and cost-effective quality you’ve come to expect from the
Andrew® portfolio of wireless solutions.
Partner with a single-source, end-to-end,
global network infrastructure provider
We address PIM with a holistic, proactive approach. Nothing is left to chance. We
begin with quality soldering and sealing. We use non-ferric designs, thorough testing
procedures, precise field installation and performance optimization to mitigate PIM
interference.
We achieve this quality by blending emerging technology with world-class expertise
and local insight supports by a global presence. Designed to support the extremely high
data rates and multi-channel counts used in applications like MIMO, Andrew -160 dBc
passives are engineered to meet spectrum allocations of 698-2700 MHz.
4
For more information, visit commscope.com
100%
Tested
Deploy proactive,
proven protection against PIM
To achieve consistent performance, every active device in your network must be
supported by a series of passive devices. Yet for every 1 dB reduction in uplink caused
by PIM, 11 percent of coverage is lost. Why take such a risk?
Instead of trying to find and replace poorly performing passive components after
installing them, use -160 dBc Passive Devices as part of your initial deployment.
• Quickly and easily view PIM test data with our WebTrak® internet app
• Offer the optimal customer experience provided by your technology
• Minimize PIM issues during system optimization
• Ensure the greatest possible coverage
• Maximize data throughput
• Accelerate time-to-market
Get the PIM
info you need
Built and tested to last
To ensure durable performance under
extreme environmental conditions, our
engineers expose components to a variety
of stringent tests:
• Electrical stress
• 10G to 50G vibrations
• Accelerated life testing (ALT/HALT)
• +85° C to -35° C temperature fluctuations
To learn more about our groundbreaking -160 Passives Devices,
contact your local CommScope
representative.
View comprehensive testing
results
for your network online using
CommScope’s WebTrak®
app. View swept frequency
plots for specific passive
component related to PIM,
VSWR, insertion loss,
isolation and coupling.
When performance is vital,
peace of mind is priceless
Every CommScope passive device is factory pretested to drive down
signal-to-noise ratio and optimize MIMO antenna performance.
When you see the Andrew brand on your CommScope couplers, hybrids,
splitters and tappers, take confidence in the performance of your network.
For more information, visit commscope.com
5
Part number descriptions
In-building Antenna Model Number Sequence
Antenna
Type
MIMO
Brand
PIM
CMAX - D M 60 - C
P
Nominal Half
Beam Width
U
S
E
i53
Frequency
Group
Outdoor Antenna Model Number Sequence
Brand
Environmental
Rating
CELLMAX - EXT - C
CELLMAX - D - C
P
P
U
U
S
S
E
E - O
Environmental
Rating
Frequency
Group
Splitter Model Number Sequence
Device
Type
PIM
Power
S - * - C
P
U
S
Number of
Outputs
Frequency
Group
E - L - N i6
Connector
Type
Coupler, Hybrid Coupler and Tapper Model Number Sequence
Device
Type
Connector
Type
H - * - C
P
Coupling
Factor
U
S
E - N - Ai6
Internal
Construction
Low IMD
Frequency
Group
Termination Model Number Sequence
Connector
Type
Termination
T
-
*
-
N
Power
Rating
PIM
M
Gender
Connector
Type
AT
-
*
-
Attenuation
6
N
-
PIM
FF
ANTENNA TYPE
O = Omni-directional
D = Directional
PIM
i6 = -160dBc Low IMD
i53 = -153dBc Low IMD
ENVIRONMENTAL RATING
O = Outdoor Rated
EXT = Exterior
FREQUENCY GROUP
T = 300-500 MHz TETRA Band
C = 800-1000 MHz Cellular/GSM Band
P = 1700-2000 MHz PCN/PCS Bands
U = 2000-2300 MHz UMTS/3G Bands
S = 2300-2400 MHz Spread Spectrum Band
E = 698-800/2400-2700 MHz Evolution Band
W = 2700-3800 MHz
NOMINAL HALF POWER BEAMWIDTH
30 = 30˚
60 = 60˚
DEVICE TYPE
S = Splitter
C = Coupler
CT = Tapper
H = Hybrid
T = Termination
AT = Attenuator
SPLITTERS
* = 2, 3, or 4 ways
L = Low power
H = High power
COUPLERS
* = Coupling: 5, 6, 8, 10, 13, 15, 20, 30 dB
A = Air dielectric low IMD
TAPPERS
* = Coupling factor: 6, 8, 10, 13, 15, 20, 30 dB
i6
Attenuator Model Number Sequence
Device Type
BRAND
CELLMAX = CommScope Cell-Max™ Antenna
CMAX = CommScope Cell-Max™ Antenna
i6
Interface
Type
For more information, visit commscope.com
HYBRIDS
* = Coupling factor: 3 dB
A = Air dielectric low IMD
TERMINATIONS
* = Max power rating: 2, 10, 25, 30, 50,100 W
M = Male
F = Female
S = Square section cooling element, default is round
Air Directional Couplers
These couplers are ideal for complex applications. They
enforce very low passive intermodulation, minimize RF
insertion loss and enable multiband frequency coverage.
•
N and DIN Connectors
•
200 W N-type, 300W DIN7-16, -160 dBc
•
IP 65 for indoor and outdoor use
•
Air dielectric version of C-x-CPUSE-x-Ai6 range
C-6-CPUSE-D-Ai6
with 7-16 DIN Female connector
C-5-CPUSE-D-Ai6
C-5-CPUSE-N-Ai6
C-6-CPUSE-D-Ai6
C-6-CPUSE-N-Ai6
C-8-CPUSE-D-Ai6
C-8-CPUSE-N-Ai6
C-10-CPUSE-D-Ai6
C-10-CPUSE-N-Ai6
7-16 DIN Female
N Female
7-16 DIN Female
N Female
200 W
300 W
General Specifications
Brand
Andrew®
Device Type
Interface
Coupler
7-16 DIN Female
N Female
7-16 DIN Female
N Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Average Power, maximum
Coupling
Two +43 dBm carriers
300 W
200 W
4.8 dB
300 W
200 W
300 W
6.0 dB
Coupling Tolerance
200 W
8.0 dB
10.0 dB
±1.0 dB
Impedance
50 ohm
Insertion Loss @ 698 – 2700 MHz
2.5 dB
1.6 dB
1.1 dB
0.7 dB
Isolation @ 698 – 2700 MHz
25 dB
26 dB
28 dB
30 dB
70 W
100 W
Peak Power, maximum
1 kW
Reflected Power, maximum
30 W
40 W
Return Loss, minimum
20.8 dB
VSWR
1.2:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
36.00 mm | 1.42 in
Length
169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
Width
74.50 mm | 2.93 in
75.00 mm | 2.95 in
74.50 mm | 2.93 in
75.00 mm | 2.95 in
74.50 mm | 2.93 in
75.00 mm | 2.95 in
74.50 mm | 2.93 in
75.00 mm | 2.95 in
Net Weight
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
Packed Dimensions
Height
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
Length
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
180.0 mm | 7.1 in
Width
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
Shipping Weight
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
For more information, visit commscope.com
7
Air Directional Couplers
C-30-CPUSE-N-Ai6
with N Female connector
C-13-CPUSE-D-Ai6
C-13-CPUSE-N-Ai6
C-15-CPUSE-D-Ai6
C-15-CPUSE-N-Ai6
C-20-CPUSE-D-Ai6
C-20-CPUSE-N-Ai6
C-30-CPUSE-D-Ai6
C-30-CPUSE-N-Ai6
7-16 DIN Female
N Female
7-16 DIN Female
N Female
200 W
300 W
General Specifications
Brand
Andrew®
Device Type
Coupler
Interface
7-16 DIN Female
N Female
7-16 DIN Female
N Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Average Power, maximum
Coupling
Two +43 dBm carriers
300 W
200 W
13.0 dB
Coupling Tolerance
300 W
200 W
300 W
15.0 dB
20.0 dB
±1.0 dB
Impedance
200 W
30.0 dB
±1.2 dB
50 ohm
Insertion Loss @ 698–2700 MHz
0.5 dB
0.4 dB
0.2 dB
0.2 dB
Isolation @ 698–2700 MHz
33 dB
35 dB
40 dB
50 dB
Peak Power, maximum
1 kW
Reflected Power, maximum
200 W
Return Loss, minimum
20.8 dB
VSWR
1.2:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
36.00 mm | 1.42 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
36.00 mm | 1.42 in
22.00 mm | 0.87 in
Length
169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in 169.00 mm | 6.65 in 155.00 mm | 6.10 in
Width
74.50 mm | 2.93 in 75.00 m m | 2.95 in 74.50 mm | 2.93 in
75.00 mm | 2.95 in
74.50 mm | 2.93 in
75.00 mm | 2.95 in
74.50 mm | 2.93 in
75.00 mm | 2.95 in
Net Weight
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
900.00 g | 1.98 lb
380.00 g | 0.84 lb
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
40.0 mm | 1.6 in
180.0 mm | 7.1 in
Packed Dimensions
Height
Length
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
Width
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
90.0 mm | 3.5 in
Shipping Weight
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
980.00 g | 2.16 lb
420.00 g | 0.93 lb
8
For more information, visit commscope.com
Attenuators
These attenuators are ideal for high power
applications where low PIM is essential.
•
Male to Female and Female to Female connector for both N-Type and DIN-type
•
100 W average power
•
IP65 for indoor and outdoor use
•
Low PIM, -160 dBc @ 2x43 dBm
AT-3-N-FFi6
AT-6-D-MFi6
with 7-16 DIN Female connector
AT-6-N-FFi6
AT-6-D-MFi6
AT-6-N-MFi6
AT-10-N-FFi6
AT-10-D-MFi6
AT-10-N-MFi6
AT-15-N-FFi6
General Specifications
Brand
Andrew®
Device Type
Attenuator
Interface
N Female
N Female
7-16 DIN Male
N Male
N Female
7-16 DIN Male
N Male
N Female
Interface 2
N Female
N Female
7-16 DIN Female
N Female
N Female
7-16 DIN Female
N Female
N Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Attenuation
3.0 dB
Attenuation Tolerance
±0.8 dB
6.0 dB
10.0 dB
15.0 dB
±1.0 dB
Average Power, maximum
100 W
Impedance
50 ohm
Return Loss, minimum
19.0 dB
VSWR
1.25:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-25 °C to +50 °C (-13 °F to +122 °F)
Relative Humidity
Up to 100%
Dimensions
Height
89.00 mm | 3.50 in
Length
210.00 mm | 8.27 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in
Width
167.00 mm | 6.57 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in
Net Weight
3.23 kg | 7.12 lb
89.00 mm | 3.50 in
3.12 kg | 6.88 lb
93.00 mm | 3.66 in
3.49 kg | 7.69 lb
89.00 mm | 3.50 in
3.16 kg | 6.97 lb
89.00 mm | 3.50 in
3.12 kg | 6.88 lb
93.00 mm | 3.66 in
3.49 kg | 7.69 lb
89.00 mm | 3.50 in
89.00 mm | 3.50 in
3.16 kg | 6.97 lb
3.12 kg | 6.88 lb
Packed Dimensions
Height
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
Length
220.0 mm | 8.7 in
270.0 mm | 10.6 in
285.0 mm | 11.2 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
285.0 mm | 11.2 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
Width
190.0 mm | 7.5 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
Shipping Weight
3.41 kg | 7.52 lb
3.29 kg | 7.25 lb
3.65 kg | 8.05 lb
3.32 kg | 7.32 lb
3.29 kg | 7.25 lb
3.65 kg | 8.05 lb
3.32 kg | 7.32 lb
3.29 kg | 7.25 lb
For more information, visit commscope.com
9
Attenuators
AT-6-N-FFi6
with N Female connector
AT-15-D-MFi6
AT-15-N-MFi6
AT-20-N-FFi6
AT-20-D-MFi6
AT-20-N-MFi6
AT-30-N-FFi6
AT-30-D-MFi6
AT-30-N-MFi6
General Specifications
Brand
Andrew®
Device Type
Attenuator
Interface
Interface 2
7-16 DIN Male
N Male
N Female
7-16 DIN Male
N Male
N Female
7-16 DIN Male
N Male
7-16 DIN Female
N Female
N Female
7-16 DIN Female
N Female
N Female
7-16 DIN Female
N Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Attenuation
Two +43 dBm carriers
15.0 dB
20.0 dB
Attenuation Tolerance
30.0 dB
±1.0 dB
Average Power, maximum
100 W
Impedance
50 ohm
Return Loss, minimum
19.0 dB
VSWR
1.25:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-25 °C to +50 °C (-13 °F to +122 °F)
Relative Humidity
Up to 100%
Dimensions
Height
93.00 mm | 3.66 in
89.00 mm | 3.50 in
89.00 mm | 3.50 in
93.00 mm | 3.66 in
89.00 mm | 3.50 in
89.00 mm | 3.50 in
93.00 mm | 3.66 in
89.00 mm | 3.50 in
Length
272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in 247.00 mm | 9.72 in 272.00 mm | 10.71 in 247.00 mm | 9.72 in
Width
130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in
Net Weight
3.49 kg | 7.69 lb
3.16 kg | 6.97 lb
3.12 kg | 6.88 lb
3.49 kg | 7.69 lb
3.16 kg | 6.97 lb
3.12 kg | 6.88 lb
3.49 kg | 7.69 lb
3.16 kg | 6.97 lb
Packed Dimensions
Height
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
Length
285.0 mm | 11.2 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
285.0 mm | 11.2 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
285.0 mm | 11.2 in
270.0 mm | 10.6 in
Width
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
Shipping Weight
3.65 kg | 8.05 lb
3.32 kg | 7.32 lb
3.29 kg | 7.25 lb
3.65 kg | 8.05 lb
3.32 kg | 7.32 lb
3.29 kg | 7.25 lb
3.65 kg | 8.05 lb
3.32 kg | 7.32 lb
10
For more information, visit commscope.com
Coaxial Loads / Terminations
These terminations/loads are ideal for high power applications
where low PIM is essential. They cover from 10 W to 100 W and
can be used to terminating unused/open RF port.
•
Male connectors and female connectors N-Type and DIN-type
•
IP65 for indoor and outdoor use
•
Low PIM, -160 dBc @ 2 x 43 dBm
T-10-DFi6
T-30-NMi6
with N Male connector
T-10-DMi6
T-10-NFi6
T-10-NMi6
T-30-DFi6
T-30-DMi6
T-30-NFi6
T-30-NMi6
7-16 DIN Female
7-16 DIN Male
N Female
N Male
General Specifications
Brand
Andrew®
Device Type
Interface
Termination Load
7-16 DIN Female
7-16 DIN Male
N Female
N Male
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +40 dBm carriers
Average Power, maximum
10 W
Two +43 dBm carriers
30 W
Impedance
50 ohm
Return Loss, minimum
19.0 dB
VSWR
1.25:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-25 °C to +50 °C (-13 °F to +122 °F)
Relative Humidity
Up to 100%
Dimensions
Diameter
44.00 mm | 1.73 in
Length
151.00 mm | 5.94 in 153.00 mm | 6.02 in 142.00 mm | 5.59 in 141.00 mm | 5.55 in 177.00 mm | 6.97 in 170.50 mm | 6.71 in 168.00 mm | 6.61 in 247.00 mm | 9.72 in
Net Weight
0.60 kg | 1.32 lb
44.00 mm | 1.73 in
0.58 kg | 1.28 lb
44.00 mm | 1.73 in
0.52 kg | 1.14 lb
44.00 mm | 1.73 in
0.52 kg | 1.14 lb
54.00 mm | 2.13 in
0.81 kg | 1.79 lb
54.00 mm | 2.13 in
815.00 g | 1.80 lb
54.00 mm | 2.13 in
89.00 mm | 3.50 in
0.76 kg | 1.68 lb
3.12 kg | 6.88 lb
Packed Dimensions
Height
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
Length
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
Width
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
Shipping Weight
0.68 kg | 1.50 lb
0.66 kg | 1.46 lb
0.60 kg | 1.32 lb
0.60 kg | 1.32 lb
0.88 kg | 1.94 lb
900.00 g | 1.98 lb
0.83 kg | 1.83 lb
840.00 g | 1.85 lb
For more information, visit commscope.com
11
Coaxial Loads / Terminations
T-50-NFi6
with N Female connector
T-50-DFi6
T-50-DMi6
T-50-NFi6
T-50-NMi6
T-100-DFi6
T-100-DMi6
T-100-NFi6
T-100-NMi6
7-16 DIN Male
N Female
N Male
75.00 mm | 2.95 in
75.00 mm | 2.95 in
General Specifications
Brand
Andrew®
Device Type
Termination Load
Interface
7-16 DIN Female
7-16 DIN Male
N Female
N Male
7-16 DIN Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Average Power, maximum
50 W
100 W
Impedance
50 ohm
Return Loss, minimum
19.0 dB
VSWR
1.25:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-25 °C to +50 °C (-13 °F to +122 °F)
Relative Humidity
Up to 100%
Dimensions
Height
74.00 mm | 2.91 in
Length
180.00 mm | 7.09 in 173.50 mm | 6.83 in 171.00 mm | 6.73 in 173.50 mm | 6.83 in 240.00 mm | 9.45 in 236.00 mm | 9.29 in 231.00 mm | 9.09 in 230.00 mm | 9.06 in
74.00 mm | 2.91 in
74.00 mm | 2.91 in
74.00 mm | 2.91 in
75.00 mm | 2.95 in
75.00 mm | 2.95 in
Width
60.00 mm | 2.36 in
60.00 mm | 2.36 in
60.00 mm | 2.36 in
Net Weight
1290.00 g | 2.84 lb
1310.00 g | 2.89 lb
1.23 kg | 2.71 lb
60.00 mm | 2.36 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in 130.00 mm | 5.12 in
1.25 kg | 2.76 lb
2.54 kg | 5.60 lb
2.53 kg | 5.58 lb
2.45 kg | 5.40 lb
2.46 kg | 5.42 lb
Height
75.0 mm | 3.0 in
65.0 mm | 2.6 in
73.0 mm | 2.9 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
105.0 mm | 4.1 in
Length
210.0 mm | 8.3 in
200.0 mm | 7.9 in
210.0 mm | 8.3 in
200.0 mm | 7.9 in
200.0 mm | 7.9 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
270.0 mm | 10.6 in
Width
90.0 mm | 3.5 in
85.0 mm | 3.3 in
90.0 mm | 3.5 in
85.0 mm | 3.3 in
85.0 mm | 3.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
135.0 mm | 5.3 in
1500.00 g | 3.31 lb
0.66 kg | 1.46 lb
1.44 kg | 3.17 lb
1.45 kg | 3.20 lb
0.88 kg | 1.94 lb
2.72 kg | 6.00 lb
2.64 kg | 5.82 lb
2.65 kg | 5.84 lb
Packed Dimensions
Shipping Weight
12
For more information, visit commscope.com
Tappers
Tappers support indoor applications in the 700 LTE band, 900 MHz
cellular/GSM band, PCS/DCS-1800 band, and the 3G band to
2700 MHz. Each unit couples a defined fraction of high-power
cellular signal with minimal reflections or loss. The wide frequency
range is ideal for multiband antennas, radiating cable systems and
in-wire base stations.
•
N and DIN Connectors
•
Low dissipation loss
•
•
CT-6-CPUSE-Di6
CT-6-CPUSE-D-Ai6
with 7-16 DIN Female connector
IP 65 for indoor and outdoor use
Spring clip makes wall mounting easy
CT-6-CPUSE-Ni6
CT-8-CPUSE-Di6
CT-8-CPUSE-Ni6
CT-10-CPUSE-Di6
CT-10-CPUSE-Ni6
CT-13-CPUSE-Di6
CT-13-CPUSE-Ni6
7-16 DIN Female
N Female
7-16 DIN Female
N Female
200 W
300 W
General Specifications
Brand
Andrew®
Device Type
Tapper
Interface
7-16 DIN Female
N Female
7-16 DIN Female
N Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 960 MHz | 1710 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Average Power, maximum
300 W
200 W
Coupling
300 W
200 W
6.0 dB
300 W
8.0 dB
Coupling Tolerance
13.0 dB
±1.0 dB
±1.25 dB
0.7 dB @ 1710–2700 MHz
0.7 dB @ 698–960 MHz
0.6 dB @ 1710–2700 MHz
0.6 dB @ 698–960 MHz
±0.8 dB
Impedance
200 W
10.0 dB
50 ohm
1.6 dB @ 1710–2700 MHz
1.6 dB @ 698–960 MHz
Insertion Loss at Frequency Band
1.1 dB @ 1710–2700 MHz
1.1 dB @ 698–960 MHz
Peak Power, maximum
3 kW
Reflected Power, maximum
200 W
Return Loss, minimum
17.7 dB
19.1 dB
20.8 dB
1.3:1
1.25:1
1.2:1
VSWR
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
28.90 mm | 1.14 in
Length
153.60 mm | 6.05 in 141.00 mm | 5.55 in 153.60 mm | 6.05 in 141.00 mm | 5.55 in 153.60 mm | 6.05 in 141.00 mm | 5.55 in 153.60 mm | 6.05 in 141.00 mm | 5.55 in
25.00 mm | 0.98 in
28.90 mm | 1.14 in
25.00 mm | 0.98 in
28.90 mm | 1.14 in
25.00 mm | 0.98 in
28.90 mm | 1.14 in
25.00 mm | 0.98 in
Width
49.30 mm | 1.94 in
43.00 mm | 1.69 in
49.30 mm | 1.94 in
43.00 mm | 1.69 in
49.30 mm | 1.94 in
43.00 mm | 1.69 in
49.30 mm | 1.94 in
43.00 mm | 1.69 in
Net Weight
350.00 g | 0.77 lb
260.00 g | 0.57 lb
350.00 g | 0.77 lb
260.00 g | 0.57 lb
350.00 g | 0.77 lb
260.00 g | 0.57 lb
350.00 g | 0.77 lb
260.00 g | 0.57 lb
50.0 mm | 2.0 in
40.0 mm | 1.6 in
50.0 mm | 2.0 in
40.0 mm | 1.6 in
50.0 mm | 2.0 in
40.0 mm | 1.6 in
50.0 mm | 2.0 in
40.0 mm | 1.6 in
Packed Dimensions
Height
Length
180.0 mm | 7.1 in
Width
95.0 mm | 3.7 in
90.0 mm | 3.5 in
95.0 mm | 3.7 in
90.0 mm | 3.5 in
95.0 mm | 3.7 in
90.0 mm | 3.5 in
95.0 mm | 3.7 in
90.0 mm | 3.5 in
Shipping Weight
420.00 g | 0.93 lb
310.00 g | 0.68 lb
420.00 g | 0.93 lb
310.00 g | 0.68 lb
420.00 g | 0.93 lb
310.00 g | 0.68 lb
420.00 g | 0.93 lb
310.00 g | 0.68 lb
For more information, visit commscope.com
13
Tappers
CT-30-CPUSE-N-Ai6
with N Female connector
CT-15-CPUSE-Di6
CT-15-CPUSE-Ni6
CT-20-CPUSE-Di6
CT-20-CPUSE-Ni6
CT-30-CPUSE-Di6
CT-30-CPUSE-Ni6
N Female
7-16 DIN Female
N Female
General Specifications
Brand
Andrew®
Device Type
Tapper
Interface
7-16 DIN Female
N Female
7-16 DIN Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 960 MHz | 1710 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Average Power, maximum
Two +43 dBm carriers
300 W
200 W
Coupling
300 W
200 W
15.0 dB
300 W
20.0 dB
Coupling Tolerance
200 W
30.0 dB
±1.25 dB
±1.5 dB
Impedance
50 ohm
Insertion Loss at Frequency Band
0.2 dB @ 1710–2700 MHz
0.2 dB @ 698–960 MHz
0.1 dB @ 1710–2700 MHz
0.1 dB @ 698–960 MHz
Peak Power, maximum
3 kW
Reflected Power, maximum
200 W
Return Loss, minimum
20.8 dB
VSWR
1.2:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
28.90 mm | 1.14 in
25.00 mm | 0.98 in
28.90 mm | 1.14 in
25.00 mm | 0.98 in
28.90 mm | 1.14 in
25.00 mm | 0.98 in
Length
153.60 mm | 6.05 in
141.00 mm | 5.55 in
153.60 mm | 6.05 in
141.00 mm | 5.55 in
153.60 mm | 6.05 in
141.00 mm | 5.55 in
Width
49.30 mm | 1.94 in
43.00 mm | 1.69 in
49.30 mm | 1.94 in
43.00 mm | 1.69 in
49.30 mm | 1.94 in
43.00 mm | 1.69 in
Net Weight
350.00 g | 0.77 lb
260.00 g | 0.57 lb
350.00 g | 0.77 lb
260.00 g | 0.57 lb
350.00 g | 0.77 lb
260.00 g | 0.57 lb
50.0 mm | 2.0 in
40.0 mm | 1.6 in
50.0 mm | 2.0 in
40.0 mm | 1.6 in
50.0 mm | 2.0 in
40.0 mm | 1.6 in
Packed Dimensions
Height
Length
180.0 mm | 7.1 in
Width
95.0 mm | 3.7 in
90.0 mm | 3.5 in
95.0 mm | 3.7 in
90.0 mm | 3.5 in
95.0 mm | 3.7 in
90.0 mm | 3.5 in
Shipping Weight
420.00 g | 0.93 lb
310.00 g | 0.68 lb
420.00 g | 0.93 lb
310.00 g | 0.68 lb
420.00 g | 0.93 lb
310.00 g | 0.68 lb
14
For more information, visit commscope.com
Hybrid Couplers
Hybrid couplers combine two wireless carriers to a single antenna
feed or cable. They maximize isolation in wireless bands by using a
few solder joints and contain an air dielectric to minimize loss and
enhance reliability. One feed requires the termination of an output
port in 50 ohms and results in a 3 dB loss per signal. Using both
outputs for two similar feeds eliminates the loss.
•
N and DIN Female Connectors
•
IP 65 for indoor and outdoor use
•
200-watt average power rating
•
Combines non-coherent signals
H-3-CPUSE-D-Ai6
with 7-16 DIN Female connector
H-3-CPUSE-D-Ai6
H-3-CPUSE-N-Ai6
General Specifications
Brand
Andrew®
Device Type
Interface
Hybrid
7-16 DIN Female
Color
N Female
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Average Power, maximum
200 W
Coupling
3.1 dB
Coupling Tolerance
±0.5 dB
Impedance
50 ohm
Insertion Loss at Frequency Band
0.2 dB @ 698–2700 MHz
Isolation at Frequency Band
26 dB @ 698–2700 MHz
Peak Power, maximum
1 kW
Reflected Power, maximum
200 W
Return Loss, minimum
20.8 dB
VSWR
1.2:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
36.00 mm | 1.42 in
Length
Width
Net Weight
26.00 mm | 1.02 in
138.00 mm | 5.43 in
96.00 mm | 3.78 in
85.00 mm | 3.35 in
0.90 kg | 1.98 lb
0.50 kg | 1.10 lb
Packed Dimensions
Height
60.0 mm | 2.4 in
50.0 mm | 2.0 in
Length
170.0 mm | 6.7 in
180.0 mm | 7.1 in
Width
110.0 mm | 4.3 in
95.0 mm | 3.7 in
Shipping Weight
1.00 kg | 2.20 lb
0.60 kg | 1.32 lb
For more information, visit commscope.com
15
Hybrid Couplers
Multiband 4x4 High Power Hybrid Matrices combine 4 input signals into 4
output signals with minimum dissipative loss. Hybrid Matrices can be used
for indoor or outdoor applications. Hybrid Matrices now use air dielectric
technology and as a result offer very low intermodulation characteristics over
a wider frequency range. A wide frequency range allows for use with single
or multiband signal sources. The device is designed to maximize the isolation
and minimize intermodulation.
•
N and 7-16 DIN Female Connectors
•
Multiband frequency ranges from LTE
700 MHz, SMR/cellular, PCS, UMTS and
3G band to 2700 MHz
•
•
•
•
H-4X4-CPUSE-DAi6
with 7-16 DIN Female connector
Minimal RF insertion loss
Low PIM, -160 dBc @ 2 x 43 dBm
High reliability
Connects 4 inputs to 4 outputs
H-4X4-CPUSE-DAi6
H-4X4-CPUSE-NAi6
General Specifications
Brand
Andrew®
Device Type
Hybrid
Interface
7-16 DIN Female
Color
N Female
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Average Power, maximum
100 W
Coupling
6.1 dB
Coupling Tolerance
±1.0 dB
Impedance
50 ohm
Insertion Loss at Frequency Band
0.3 dB @ 698–2700 MHz
Isolation at Frequency Band
25 dB @ 698–2700 MHz
Peak Power, maximum
1 kW
Reflected Power, maximum
100 W
Return Loss, minimum
20.8 dB
VSWR
1.2:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-31 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
34.00 mm | 1.34 in
31.00 mm | 1.22 in
Length
191.00 mm | 7.52 in
181.00 mm | 7.13 in
Width
191.00 mm | 7.52 in
181.00 mm | 7.13 in
1.80 kg | 3.97 lb
1.50 kg | 3.31 lb
Net Weight
Packed Dimensions
Height
45.0 mm | 1.8 in
Length
210.0 mm | 8.3 in
Width
210.0 mm | 8.3 in
Shipping Weight
16
2.30 kg | 5.07 lb
For more information, visit commscope.com
2.00 kg | 4.41 lb
High Power Splitters
Multiband high-power splitters evenly distribute high-power signals
with minimal reflections or loss. The reactive design employs no
resistors, eliminating potential PIM damage. The SMR, PCS, UMTS
and LTE frequency range enables use with single or multiband
antennas and radiating cable systems. Minimal solder joints and
an air dielectric enhance reliability.
•
7-16 DIN Female Connectors
•
IP 65 for indoor and outdoor use
•
Low dissipation loss
•
Spring clip makes wall mounting easy
S-2-CPUSE-H-Di6
S-2-CPUSE-H-Ni6
S-4-CPUSE-H-Ni6
with N Female connector
S-3-CPUSE-H-Di6
S-3-CPUSE-H-Ni6
S-4-CPUSE-H-Di6
S-4-CPUSE-H-Ni6
N Female
7-16 DIN Female
N Female
General Specifications
Brand
Andrew®
Device Type
Interface
Splitter
7-16 DIN Female
N Female
7-16 DIN Female
Color
Silver
Electrical Specifications
Operating Frequency Band
698 – 2700 MHz
3rd Order IMD
-160 dBc (relative to carrier)
3rd Order IMD Test Method
Two +43 dBm carriers
Average Power, maximum
300 W
Impedance
50 ohm
Insertion Loss at Frequency Band
0.2 dB @ 698–2700 MHz
0.3 dB @ 698–2700 MHz
Peak Power, maximum
3 kW
Power Rating, Splitting
300 W
Reflected Power, maximum
300 W
Return Loss, minimum
20.8 dB
Split Loss
17.7 dB
3.0 dB
4.8 dB
VSWR
6.0 dB
1.2:1
1.3:1
Mechanical Specifications
Inner Contact Plating
Silver
Outer Contact Plating
Trimetal
Environmental Specifications
Application
Indoor/Outdoor
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
-35 °C to +85 °C (-13 °F to +185 °F)
Relative Humidity
Up to 100%
Dimensions
Height
25.00 mm | 0.98 in
25.00 mm | 0.98 in
49.00 mm | 1.93 in
43.00 mm | 1.69 in
49.00 mm | 1.93 in
43.00 mm | 1.69 in
Length
156.00 mm | 6.14 in
150.00 mm | 5.91 in
165.00 mm | 6.50 in
159.00 mm | 6.26 in
239.00 mm | 9.41 in
227.00 mm | 8.94 in
Width
73.00 mm | 2.87 in
61.00 mm | 2.40 in
73.00 mm | 2.87 in
61.00 mm | 2.40 in
73.00 mm | 2.87 in
61.00 mm | 2.40 in
Net Weight
382.00 g | 0.84 lb
261.00 g | 0.58 lb
459.00 g | 1.01 lb
300.00 g | 0.66 lb
590.00 g | 1.30 lb
390.00 g | 0.86 lb
Height
40.0 mm | 1.6 in
40.0 mm | 1.6 in
65.0 mm | 2.6 in
65.0 mm | 2.6 in
75.0 mm | 3.0 in
62.0 mm | 2.4 in
260.0 mm | 10.2 in
Packed Dimensions
Length
180.0 mm | 7.1 in
180.0 mm | 7.1 in
170.0 mm | 6.7 in
170.0 mm | 6.7 in
290.0 mm | 11.4 in
Width
90.0 mm | 3.5 in
90.0 mm | 3.5 in
110.0 mm | 4.3 in
110.0 mm | 4.3 in
98.0 mm | 3.9 in
82.0 mm | 3.2 in
Shipping Weight
445.00 g | 0.98 lb
318.00 g | 0.70 lb
546.00 g | 1.20 lb
380.00 g | 0.84 lb
690.00 g | 1.52 lb
470.00 g | 1.04 lb
For more information, visit commscope.com
17
CMAX SISO and MIMO Antennas
These compact wideband antennas are designed to last and 100% tested for VSWR and PIM. Low IMD versions are
treated with even further attention to detail: all joints are soldered, and only the very highest quality components are used.
•
•
•
•
Multiband frequency range:
SMR/cellular, PCS, UMTS,
and LTE
Homogenous patterns
Solid PIM performance
Compact design
CMAX-OMF1-CPUSEi53
CMAX-DMF-CPUSEi53
CMAX-D-CPUSEi53
CMAX-O-CPUSEi53
CMAX-OMH-CPUSEi53
Omni MIMO
Directional MIMO
Directional SISO
Omni SISO
Omni MIMO
Thru-hole ceiling mount (optional)
Thru-hole ceiling mount (optional)
General Specifications
Antenna Type
Application
Indoor
Operating Frequency Band
698 – 960 MHz | 1710 – 2700 MHz
Brand
Andrew®
Includes
Mounting bracket
Mount Type
Thru-hole ceiling mount (optional)
Number of Ports, all types
2
4-hole wall mounting plate and hardware
2
Package Quantity
1
2
1
Pigtail Cable
670-141SXE, plenum rated
Electrical Specifications
PIM Value
3rd Order IMD -153 dBc (2 x 20 W, dBc)
Gain, dBi
Beamwidth, Horizontal, degrees
4.0 @ 698 – 800 MHz
6.4 @ 698 – 800 MHz
6.0 @ 698 – 800 MHz
2.0 @ 698 – 800 MHz
1.5 @ 698 – 800 MHz
4.2 @ 800 – 960 MHz
7.2 @ 800 – 960 MHz
6.0 @ 800 – 960 MHz
2.0 @ 800 – 960 MHz
1.5 @ 800 – 960 MHz
5.5 @ 1710 – 2200 MHz
7.8 @ 1710 – 2200 MHz
7.0 @ 1710 – 2200 MHz
2.4 @ 1710 – 2200 MHz
3.5 @ 1710 – 2200 MHz
5.5 @ 2200 – 2700 MHz
7.6 @ 2200 – 2700 MHz
7.0 @ 2200 – 2700 MHz
3.3 @ 2200 – 2700 MHz
4.3 @ 2200 – 2700 MHz
360 @ 698 – 800 MHz
75 @ 698 – 800 MHz
90 @ 698 – 800 MHz
360 @ 698 – 800 MHz
360 @ 800 – 960 MHz
68 @ 800 – 960 MHz
83 @ 800 – 960 MHz
360 @ 800 – 960 MHz
360 @ 1710 – 2200 MHz
74 @ 1710 – 2200 MHz
65 @ 1710 – 2200 MHz
360 @ 1710 – 2200 MHz
360 @ 2200 – 2700 MHz
67 @ 2200 – 2700 MHz
88 @ 2200 – 2700 MHz
360 @ 2200 – 2700 MHz
Beamwidth, Vertical, degrees
78.0 @ 698 – 800 MHz
72.0 @ 698 – 800 MHz
48.0 @ 698 – 800 MHz
55.0 @ 698 – 800 MHz
62.0 @ 800 – 960 MHz
53.0 @ 800 – 960 MHz
48.0 @ 800 – 960 MHz
55.0 @ 800 – 960 MHz
62.0 @ 1710 – 2200 MHz
46.0 @ 1710 – 2200 MHz
35.0 @ 1710 – 2200 MHz
42.0 @ 1710 – 2170 MHz
69 @ 2200 – 2700 MHz
50.0 @ 2200 – 2700 MHz
35.0 @ 2200 – 2700 MHz
42.0 @ 2200 – 2700 MHz
Vertical
Vertical @ 698 – 800 MHz | Vertical
@ 800 – 960 MHz | Horizontal/
Vertical @ 1710 – 2700 MHz
Frequency Band, MHz
698 – 960 / 1710 – 2700
Polarization at Frequency Band
±45°
Impedance
Vertical
50 ohm
Mechanical Specifications
Color
White
Pigtail Length
Radome Material
500.0 mm | 19.7 in
450.0 mm | 17.7 in
420.0 mm | 16.5 in
500.0 mm | 19.7 in
ABS, UV resistant
ABS, UV resistant
ABS
ABS, UV resistant
RF Connector Interface
N Female
Environmental Specifications
Operating Temperature
-40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity
Up to 100%
Dimensions
Depth
Height
Length
Width
Outer Diameter
Net Weight
18
72.0 mm | 2.8 in
62 mm | 2.4 in
318.0 mm | 12.5 in
262.0 mm | 10.3 in
210.0 mm | 8.3 in
180.0 mm | 7.1 in
1.0 kg | 2.2 lb
850.0 g | 1.9 lb
45.0 mm | 1.77 in
200.0 mm | 7.9 in
0.5 kg | 1.0 lb
For more information, visit commscope.com
135.00 mm | 5.31 in
119.00 mm | 4.69 in
204.0 mm | 8.0 in
204.0 mm | 8.0 in
0.4 kg | 0.9 lb
0.5 kg | 1.1 lb
CMAX SISO and MIMO Antennas
These antennas complement our omni-directional antennas and employ the exact same attention-to-detail in build quality.
•
Low PIM and outdoor variants
•
Homogenous patterns
•
Compact design
•
High gain
CMAX-OMF-CPUSEi53
CMAX-DM20-CPUSEi53
CMAX-DM30-CPUSEi53
CMAX-DM60-CPUSEi53
CMAX-EXT-CPUSEi53
General Specifications
Antenna Type
Omni
Directional MIMO
Directional SISO
Application
Indoor
Indoor | Outdoor
Outdoor
Operating Frequency Band
698 – 960 MHz | 1710 – 2700 MHz
Brand
Andrew®
Includes
Mount Type
Mounting bracket
Poles between 30 – 55 mm with supplied
clamps
Thru-hole ceiling mount (optional)
Number of Ports, all types
2
1
Package Quantity
1
Electrical Specifications
PIM Value
Gain, dBi
Beamwidth, Horizontal, degrees
3rd Order IMD -153 dBc (2 x 20 W, dBc)
2.0 @ 698 – 800 MHz
12.0 @ 698 – 800 MHz
10.7 @ 698 – 800 MHz
8.5 @ 698 – 800 MHz
10.0 @ 698 – 800 MHz
2.0 @ 800 – 960 MHz
13.4 @ 800 – 960 MHz
11.2 @ 800 – 960 MHz
9.2 @ 800 – 960 MHz
11.0 @ 800 – 960 MHz
4.0 @ 1710 – 2200 MHz
12.5 @ 1710 – 2200 MHz
10.7 @ 1710 – 2200 MHz
9.2 @ 1710 – 2200 MHz
11.0 @ 1710 – 2170 MHz
4.0 @ 2200 – 2700 MHz
13.7 @ 2200 – 2700 MHz
11.1 @ 2200 – 2700 MHz
9.2 @ 2200 – 2700 MHz
11.0 @ 2200 – 2700 MHz
360 @ 698 – 800 MHz
26 @ 698 – 800 MHz
34 @ 698 – 960 MHz
62 @ 698 – 800 MHz
68 @ 698 – 800 MHz
360 @ 800 – 960 MHz
23 @ 800 – 960 MHz
29 @ 1710 – 2200 MHz
59 @ 800 – 960 MHz
60 @ 800 – 960 MHz
360 @ 1710 – 2200 MHz
22 @ 1710 – 2200 MHz
33 @ 1710 – 2200 MHz
54 @ 1710 – 2200 MHz
60 @ 1710 – 2170 MHz
360 @ 2200 – 2700 MHz
18 @ 2200 – 2700 MHz
30 @ 2200 – 2700 MHz
62 @ 2200 – 2700
52 @ 2200 – 2700 MHz
Beamwidth, Vertical, degrees
63.0 @ 698 – 800 MHz
66.0 @ 698 – 960 MHz
62.0 @ 698 – 800 MHz
30.0 @ 698 – 800 MHz
61.0 @ 800 – 960 MHz
62.0 @ 800 – 960 MHz
58.0 @ 800 – 960 MHz
28.0 @ 800 – 960 MHz
63.0 @ 1710 – 2200 MHz
57.0 @ 1710 – 2200 MHz
55.0 @ 1710 – 2200 MHz
30.0 @ 1710 – 2200 MHz
60.0 @ 2200 – 2700 MHz
58.0 @ 2200 – 2700 MHz
62.0 @ 2200 – 2700 MHz
30.0 @ 2200 – 2700 MHz
Frequency Band, MHz
698 – 960 / 1710 – 2700
Impedance
Polarization
50 ohm
Horizontal | Vertical
±45°
Vertical
Mechanical Specifications
Color
White
Radome Material
RF Connector Interface
Off-white
White
ABS, UV resistant
PVC, UV resistant
N Female
7-16 DIN Female
686.0 N @ 216 km/h |
154.2 lbf @ 216 km/h
Wind Loading, maximum
Wind Speed, maximum
294.0 N @ 216 km/h |
66.1 lbf @ 216 km/h
216.0 km/h | 134.2 mph
Environmental Specifications
Ingress Protection Test Method
IEC 60529:2001, IP65
Operating Temperature
IEC 60529:2001, IP66
-40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity
Up to 100%
Vibration Test Method
ASTM D4169 | IEC 60068-2-6
Dimensions
Depth
Height
127.0 mm | 5.0 in
127.0 mm | 5.0 in
124.5 mm | 4.9 in
98.0 mm | 3.9 in
150.0 mm | 1.77 in
Length
881.4 mm | 34.7 in
609.6 mm | 24.0 in
299.7 mm | 11.8 in
620.0 mm | 24.4 in
Width
340.4 mm | 13.4 in
340.4 mm | 13.4 in
299.7 mm | 11.8 in
331.0 mm | 13.0 in
8.0 kg | 17.6 lb
7.0 kg | 15.4 lb
2.9 kg | 6.4 lb
4.7 kg | 10.4 lb
Outer Diameter
Net Weight
230.0 mm | 9.1 in
For more information, visit commscope.com
19
CommScope (NASDAQ: COMM)
helps companies around the world
design, build and manage their wired
and wireless networks. Our network
infrastructure solutions help customers
increase bandwidth; maximize existing
capacity; improve network performance
and availability; increase energy
efficiency; and simplify technology
migration. You will find our solutions
in the largest buildings, venues and
outdoor spaces; in data centers and
buildings of all shapes, sizes and
complexity; at wireless cell sites and in
cable headends; and in airports, trains,
and tunnels. Vital networks around the
world run on CommScope solutions.
www.commscope.com
Visit our website or contact your local CommScope representative for more information.
© 2015 CommScope, Inc. All rights reserved.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc.
This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.
BR-108070.2-EN (08/15)