Circuit Protection Accessories You maintain the circuit. We’ll maintain an inventory of accessories to help. Your problem: The little things that make your job easier add up. Maybe it’s a lockable cabinet to keep your spares from being scattered across the plant. Maybe it’s having the right fuse puller, so your people don’t put themselves at risk by “improvising” • Box Covers during fuse changeouts. Or maybe you’re an OEM designer or • Fuse Reducers specifying engineer, and that circuit protection problem you’ve • Fuse Pullers, Clip Clamps been wrestling with would disappear if fuses came with a special • Trigger® Indicator gadget that . . . • Shawmut Trigger® Our solution: Look no further than Ferraz Shawmut’s line of • Trigger® Actuator Circuit Protection Accessories. Cabinets, box covers, reducers, • Blown Fuse Indicators pullers, blown-fuse indicators, add-on switches . . . they’re all here. In stock. Under one roof. And ready to meet your circuit • Add-on Switches protection system maintenance needs — or help you solve • IL Indicator specialized design problems. • PSC Microswitches Want more information fast? For more technical or application- • Protistor Microswitches specific information, please call our Circuit Protection Accessories experts, at 978-462-6662; 416-252-9371 in Canada; or visit our website at us.ferrazshawmut.com. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com BOX COVERS ACCESSORIES BOX COVERS COU COW COX Ferraz Shawmut Box Covers fit all standard size boxes with a variety of plug fuse, switch and receptacle combinations. They provide easy access to local protection and control of 125V motors and other equipment. Long life corrosion-protected steel bases. Rating & Approval ➤ Rated 125V AC 15A ➤ UL Listed COY CRU CRW CRX CRY CSU CSW CSX CSY Note: Features and box mounting details on next page. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J BOX COVERS COY-B CCY CATALOG NO. COU COW COX COY CRU CRW BOX COVER FEATURES ACCESSORIES CTY CKA TO MOUNT ON: Edison-Base Fuse Holder 2-1/4” Handy Box Edison-Base Fuse Holder 2-3/4” Switch Box Edison-Base Fuse Holder 4” Octagon Box Edison-Base Fuse Holder 4” Square Box Edison-Base Fuse Holder 2-1/4” Handy Box and Grounding Receptacle Edison-Base Fuse Holder and Grounding Receptacle 2-3/4” Switch Box CRX Edison-Base Fuse Holder and Grounding Receptacle 4” Octagon Box CRY CSU Edison-Base Fuse Holder 4” Square Box and Grounding Receptacle CSW CSY-RL CSY-L Edison-Base Fuse Holder 2-1/4” Handy Box and Single Pole Switch Edison-Base Fuse Holder 2-3/4” Switch Box and Single Pole Switch CATALOG NO. BOX COVER FEATURES TO MOUNT ON: CSX Edison-Base Fuse Holder 4” Octagon Box and Single Pole Switch CSY Edison-Base Fuse Holder and Single Pole Switch 4” Square Box COY-B CSY-L CSY-RL 2 Edison-Base Fuse Holders 4” Square Box Edison-Base Fuse Holder Single Pole Switch and Pilot Light 4” Square Box Edison-Base Fuse Holder Grounding Receptacle Single Pole Switch and Pilot Light 4” Square Box CCY CKA CTY 2 Edison-Base Fuse Holders and 2 Single Pole Switches 4” Square Box J 2 Edison-Base Fuse Holders 4-11/16” Square Box & 250V Grounding Receptacle 2 Edison-Base Fuse Holders 4” Square Box and one 2-Pole Switch Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J FUSE REDUCERS ACCESSORIES FUSE REDUCERS Ferraz Shawmut Fuse Reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection Reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type Reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications. Ratings ➤ For 250 and 600 Volt Class H, K and R fuses ➤ For 600 Volt Class J fuses Approvals ➤ UL Listed Guide No. IZZR ➤ CSA Certified ➤ 30 to 600 amperes ➤ Tested to 200,000A Fuse Reducers – Catalog Numbers CATALOG NUMBERS CLASS H & K (NON-REJECTION) CLASS R (REJECTION) CLASS J (REJECTION) DESCRIPTION 250 VOLTS 632 132 162 R632 R132 R162 - - - Allows 30A fuse to fit 60A clips Allows 30A fuse to fit 100A clips Allows 60A fuse to fit 100A clips 262 212 412 R262 R212 R412 - - - Allows 60A fuse to fit 200A clips Allows 100A fuse to fit 200A clips Allows 100A fuse to fit 400A clip 422 612 622 642* R422 R612 R622 R642* - - - - Allows 200A fuse to fit 400A clips Allows 100A fuse to fit 600A clips Allows 200A fuse to fit 600A clips Allows 400A fuse to fit 600A clips 600 VOLTS 636 162 166 R636 R162 R166 J636 J136 J166 Allows 30A fuse to fit 60A clips Allows 30A fuse to fit 100A clips Allows 60A fuse to fit 100A clips - 266 212 412 - R266 R212 R412 J236 J266 J216 J416 Allows 30A fuse to fit 200A clips Allows 60A fuse to fit 200A clips Allows 100A fuse to fit 200A clips Allows 100A fuse to fit 400A clips 422 612 622 642* R422 R612 R622 R642* J426 J616 J626 J646 Allows 200A fuse to fit 400A clips Allows 100A fuse to fit 600A clips Allows 200A fuse to fit 600A clips Allows 400A fuse to fit 600A clips *Not a pair; rejection end piece only. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J FUSE PULLERS/CLIP CLAMPS ACCESSORIES FUSE clip clamps Ferraz Shawmut Fuse Clip Clamps are used to clamp fuse clips together onto a fuse ferrule or blade. An easy twist of the cap tightens the jaws against the clip, preventing heating by reducing resistance at the point where fuse and clip make contact. This helps prevent loss of spring tension due to annealing from overheating. plastic FUSE pulleRS Ferraz Shawmut Plastic Fuse Pullers are fully insulated, made of high-dielectric, reinforced plastic with notched handles to provide a safe grip. Stronger and more durable than fiber pullers, they are permanently marked with the recommended fuse ampere range. Yellow color for safety. Plastic Fuse Pullers – Catalog Numbers, Sizes DESCRIPTION CATALOG NUMBER SIZE LENGTH (inches) USE WITH FUSES AMPERE DIAMETER RATING VOLTS (inches) 34-001G small 5 0-30 34-002G pocket 7-1/2 0-100 34-003G 31-600 large 11-3/4 31-400 32-250 250 600 250 600 9/32-1/2 - Fuse Clip Clamps – Catalog Numbers, Type, Ratings Ferraz Shawmut Nylon Fuse Pullers are fully insulated, made of high-dielectric, high impact nylon with no-slip handles and protective finger stops for greater safety when inserting fuses. Yellow color for safety. Nylon Fuse Pullers – Catalog Numbers, Sizes DESCRIPTION CATALOG NUMBER SIZE LENGTH (inches) 34-015G small 5 34-016G medium 7-1/4 32-004G 32-005G 32-006G* knife blade 32-007G 100 200 250 400 or 600 600 WEIGHT (ounces) 2 2 2 8 8 * Wide jaws permit clamping split clips. J nylon FUSE pullERS CATALOG USE WITH FUSE CLIPS NUMBER TYPE AMPERES VOLTS 32-001G Ferrule 30 250 32-002G Ferrule 60 250 32-002G Ferrule 30 600 32-003G Ferrule 60 600 USE WITH FUSES AMPERE RATING VOLTS 0-30 0-100 0-60 250 250 600 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J BLOWN FUSE INDICATORS ACCESSORIES TRIGGER® INDICATOR Before After The Trigger Indicator (Catalog Number suffix TI) is available on many blade type fuses, primarily Form 101 semiconductor fuses and some Class L fuses. The TI allows blown fuses to be identified visually, eliminating the need for resistance or continuity testing. After Before Catalog Numbers shawmut TRIGGER® The Shawmut Trigger Indicator is a field-mountable blown-fuse indicator which is wired in parallel with the fuse to be monitored. The striker pin exerts a static force of one pound and may be used to actuate a switch. It is available in 130 volt (TI-130), 600 volt (TI-600), and 1500 volt (TI-1500) ratings. The TI-600 Trigger is a UL Listed accessory. The Shawmut Trigger is not a fuse and should only be used in parallel with fuses rated 70A or higher. To mount the Trigger, use two midget fuse clips (for 13/32” diameter fuses) found in the Fuse Clip section. CAT. NO. VOLTS LENGTH A-in. TI-130 TI-600 TI-1500 0-130 0-600 0-1500 2 2 3-1/2 TRIGGER® actuator The Trigger Actuator (catalog number suffix TA) has two functions and is an option available on many Amp-trap® fuses. First, it provides visual indication of an open fuse and second, it provides a mount for an Add-On-Switch (AOS-) which can indicate a blown fuse via a signal light or initiate appropriate control action. The Trigger Actuator has no measurable I2t or arc voltage effect on fuses rated 65A or higher. It will add 2 to 5 amperes of long term rating and requires a minimum circuit voltage of 5 to 10 volts to activate. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J BLOWN FUSE INDICATORS ACCESSORIES AOS-Q add-on-switch Add-On-Switches contain one single-pole doublethrow contact rated 4 amperes resistive and 1 ampere inductive at 250V AC maximum. Two versions of the Add-On-Switch are available. Catalog number AOS-S has screw terminals. Catalog number AOS-Q accommodates push-on connectors. AOS-S Mounted on fuse AOS-S IL INDICATOR The new “IL” indicator, developed from proven designs, provides a blown fuse indication system which does not sacrifice the excellent I2t characteristics of Ferraz fuses. Its low voltage design requires just 0.9 volts to activate the indicator, thus insuring reliable fuse performance under all conditions. The red pop up button is located in the center of the fuse body for ease of visibility and optimum voltage isolation. Interference with buss bar and cable connection is significantly less than other designs. The addition of the “IL” indicator provides blown fuse indication on virtually all Ferraz fuses. Optional auxiliary microswitches for remote signaling are also available for use with the “IL” indicator. Features/benefits J ➤ Visual Indication or Remote Signaling HIGHLIGHTS: ➤ Optional Auxiliary Microswitches ➤ Low Voltage Design ➤ Center Location ➤ Rugged Construction ➤ Proven Reliability ➤ AC or DC ➤ UL Recognized ➤ Same Size for All Fuses ➤ Retains Optimum Performance ➤ Operation at All Times Above 0.9 Volts - For blown fuse indication on general purpose fuses, please consult factory. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J MICROSWITCHES & STUDS ACCESSORIES Features/benefits ➤ Microswitch systems adapted to the following fuses: - PSC sizes 30, 31, 32, 33 / 70, 71, 72, 73 - Blade-type PSC (PA) sizes 0-1, 2-3 / 70, 71, 72, 73 - PSC sizes 000 / 00 ➤ Highly resistant studs offering optimized connection, excellent electrical contact and high mechanical withstand for stud-style fuses. Applications Data AC IMPULSE INTERRUPTING RATING AC POSITIVE RATED NATURE OF VOLTAGE VOLTAGE FIRE CODE VOLT OPERATING CURRENT CURRENT NON -INDUCTIVE CIRCUIT INDUCTIVE CIRCUIT WITHSTAND TEST CLASS TEST UIMP 1.2/50 UL 94 *** VOLT/CURRENT 30V 110V 250V 30V 110V 250V 20 V 10 A MS 3V 1-5 1000 V 50 mA MS 7V 1-5 1500 V MS 10 V 3 A 3V 1-5 BS 1000 V MS 3V 1-9 BS MS 7V 1-5 BS 1500V 10 mA MS 7V 1-9 BS 50/60 Hz 10A 10A 10A 10A 10A 10A 8,5 kV* 14 kV** DC 8A 0,4A .2A 4A .2A .1A 12 kV* 20 kV** 3A 3A 3A 2A 1A 1A 8,5 kV* 14 kV ** DC 3A 0,5A 0,25A 3A 0,2A 0,1A 12 kV* 20 kV** MS 3V 1-5 ET 1000V 50/60 Hz 3A 3A 3A 2A 1A 1A 8.5 kV* 14 kV** 10 V H.B 50/60 Hz 3 A MS 7V 1-5 ET 1500V 10 mA DC 3A 0.5A - 2A 0.2A - 12 kV* 20 kV** H.B. MS PA 2-5 1500 V 20 V 50/60 Hz 10A 10A 10A 10A 10A 10A 9 kV* 13 kV** 10 A MS PA 2-9 50 mA DC 8A 0,4A 0,2A 4A 0,2A 0,1A VO S PA 2-5 B2 1500 V M 20 V 50 Hz 4A 4A 5A - 5A 5A 12 kV* 16 kV** 5 A MS 4L 2-5 B2 1000 V 100 mA DC - - - - 2A 0,4A 8 kV* 13 kV** VO S 4L 2-5 B6 1000 V M 20 V 50/60 Hz 10A 10A 10A 10A 10A 10A 8 kV* 10 kV** 10 A 50 mA DC 8A 0,4A 0,2A 4A 0,2A 0,1A VO MC 6,3 GR 2-5N 1000 V 20 V 50/60 Hz - 5A 3A - 3A 2A 3.5 kV* 5A 100 mA DC 4A 0.4A - 3A 0.4A MC 36 GR 2-5 1000 V 20 V 50/60 Hz - 5A 5A - 5A 5A 7.5 kV* 5A 100 mA DC 4A 0.4A - 2A 0.4A - H.B. * Between power circuit and microswitch terminals as per IEC 60 and 694 and NFC 64010 (50/60 Hz 1 min. duration in dry air) ** Between power circuit and microswitch terminals Uimp: impulse voltage as per IEC 947-1 ***Between power circuit and microswitch terminals EACH MICROSWITCH WEIGHS LESS THAN 100 g, THEREFORE NO FUME AND SMOKE GRADE IS REQUIRED BY NF F 16-102 STANDARD Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J PSC MICROSWITCHES MS 3V Fuse Sizes: 30 - 33 2 4 ACCESSORIES 1 Fig. 1 X31 MS30014 V1-5 42 Fuse Size Code 39 Sizes 30, 31, 32, 33 position déclenchée switched position 10 6.35 x 0.8 2 1 4 X310014 MS3V1-5 34.6 Fig. 2 32.7 Ref. Number Indication Style Weight (g) MS 3V 1-5 X310014 Standard NO-NC 34 MS 3V 1-5 Low level NO-NC BS W310013 34 MS 3V 1-9 BS T310011 Low level NO-NC 44 MS 3V 1-5 ET R310009 Low level NO-NC 34 (fig.1) (3) (4) (fig. 3) 10 4.75 x 0.5 1 2 R310009 MS3V1-5 ET 4 (3) Same as fig. 1 (4) Same dimensions as fig. 1 but with 2 microswitches side by side (9) Watertightness class Fig. 3 32.7 Fuse Size Code 1 K MS731000 V1-5 3 BS Fig. 4 42 62,5 10 4.75 x 0.5 1 2 4 S310010 MS7V1-5 ET 32.7 Indication Style Weight (g) MS 7V 1-5 J310002 Standard NO-NC 45 MS 7V 1-5 BS K310003 Low level NO-NC 45 Sizes 70, 71, 72, 73 MS 7V 1-9 BS P310007 Double pole NO-NC 55 MS 7V 1-5 ET S310010 Low level NO-NC 55 Fig. 5 Ref. Number (fig.4) (7) (8) (fig. 5) low level IP 50 (9) (7) Same as fig. 4 (8) Same dimensions as fig. 4 but with 2 microswitches side by side (9) Watertightness class Attention: Microswitch systems exclusively designed for Ferraz Shawmut PSC fuses are fitted with a patented trip-indicator, saving the use of an EDV. J MS PA Fuse Sizes: 0 - 70 Fuse Size Code Ref. Number Indication Style Weight (g) Sizes MS PA 2-5 H210158 OF Standard (fig. 7) 32,5 0, 1, 2, 3, MS PA 2-9V J210159 Double (fig. 7) OF 39,5 71, 72, 73 side by side MS PA 2-5 B2 C210360 OF Terminals 2,8 27 Fig. 7 MS PA 2-5 T210398 OF Standard (fig. 7) 70 MS PA 2-9 V210399 Double (fig. 7) OF side by side MS PA 2-5 B2 W210400 OF Terminals 2,8 (fig. 8) Fig. 8 31 37 27 Exclusive “MS PA” indication systems are automatically resettable Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J PSC MICROSWITCHES ACCESSORIES MS Indication System for 000 & 00 Fuses as per DIN 43653 and DIN 43620 Terminals Catalog Number Automatically resettable, these microswitch systems indicate fuse presence (PRES) and proper mounting. In case of improper mounting or fuse melting, terminals 1-4 closed. Reference Number Weight (g) MS 4L 2-5 B6 + PRES (fig. 1) (1) F210156C 30 MS 4L 2-5 B2 + PRES (fig. 2) (2) G210157C 26 (1) 6.3mm Clips (2) 2.8mm Clips Fig. 1 Fig. 2 MC Indication System for BS 88-4 Blown Fuse Trip-Indicator 8,5 20 7 31 Catalog Number Reference Number Weight (g) Y 310015 10 Reference Number Weight (g) MC 6,3 GR 2-5 N with external trip-indicator 11 23 33 28,5 15 Catalog Number 8,4 27 26 23,6 22,5 2,8 13 3,4 MC 36 GR 2-5 for British standard fuses with internal indicator P 092496 10 27 and 36 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J 10 PROTISTOR FUSE MICROSWITCHES ACCESSORIES PROTISTOR® FUSES Microswitch systems for round and square-body fuses (not for PSC Fuses) Features/benefits ➤ Remote signaling systems for fitting on Ferraz Shawmut fuses equipped with microswitch support ➤ Indication of fuse status ➤ Manual Reset ➤ Standard and low current models with different insulation ratings ➤ Watertight types for use in corrosive atmospheres CHARACTERISTICS TYPE Standard AC or DC Impulse AC voltage Insulation voltage test CATALOG NUMBER voltage withstand test Uimp 1,2/50 hs rating (*) (**) Ui (V) MC3E 1-5N 1250V 15 kV 20 kV 20 V MCR3E 1-5N 2200V 20 kV 30 kV 50 mA 1250V 15 kV 20 kV MC3E 1-5NBS MC3E 1-9NBS Low level MCR3E 1-5NBS 20 kV (1) 30 kV MC3E 1-5NET 1250V MCR3E 1-5NET 2200V 20 kV (1) 30 kV MC2R3E 1-5NET 6000V 24 kV (2) 40 kV MC2R3E 1-9NBS IP 50 2200V 23 kV (2) 24 kV (1) 26 kV (2) 32 kV (3) 11 kV MCR3E 1-9NBS MC2R3E 1-5BS Watertight Positive operating min.voltage /min.current 6000V 10 V 10 mA Current rating 5A Current Non-inductive circuit 30 V 110 V 250 V 50/60 Hz 10 A 10 A 7A DC 5A 0.5 A 50/60 Hz 3A 3A DC 3A inductive circuit L/R = 25ms 30 V 110 V 250 V 6A 1.6 A 0.3A 3A 2A 1A 1A 0.5 A 0.25 A 3A 0.2 A 0.1 A 50 Hz 3A 3A 1A 1A DC 0.5A 3A 40 kV 16 kV 10 V 10 mA 3A J 0.2 A Catalog Numbering system: MC3E 1-5 single pole microswitch - MC3E 1-9 double pole microswitch - MCR, MC2R reinforced insulation microswitch * Between power circuit and microswitch terminals as per IEC 60 and 694 and NFC 64010 (50/60 Hz 1 min. duration in dry air) ** Between power circuit and microswitch terminals Uimp: impulse voltage accordong to IEC 947-1 ***Between power circuit and microswitch terminals EACH MICROSWITCH WEIGHS LESS THAN 100g, THEREFORE NO FUME AND SMOKE GRADE IS REQUIRED BY NF F16-102 STANDARD (1) for short body fuses (sizes 30 - 31 - 32 - 33 - 70 - 71 - 72 - 73 - 83 - 84) Except PSC (2) for sizes 100 - 91 - 92 - 93 - 94 - 123 - 124 fuses and longer (3) for sizes 171 - 172 - 173 - 174 fuses and longer Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J 11 Semiconductor Fuses SSeSem iiccioconondnduducuctctootror rFFuFususesesess emm Microswitches Microswitches Microswitches Microswitches ® Microswitch Systems Protistor Fuses ® ® ®Fuses Microswitch Systems Protistor PROTISTOR FUSE MICROSWITCHES ACCESSORIES Microswitch Systems Protistor Fuses Microswitch Systems Protistor Fuses REMOTE SIGNALING WITH 1250 V AC/DC INSULATION VOLTAGE REMOTE SIGNALING WITH 1250Insulation V AC/DC INSULATION VOLTAGE Remote Signalling with 1250 VWITH AC/DC Voltage Catalog REMOTE SIGNALING 1250 V AC/DC INSULATION VOLTAGE Quantity of NO-NC REMOTE SIGNALING WITH 1250 V AC/DC INSULATION VOLTAGE Contact Ref. Weight Pack. Number separated circuits (g) (1) Number Weight Pack. Catalog Quantity of NO-NC Ref. Quantity of NO-NC Catalog Ref. Weight Pack. Contact WeightPack. Pack. Catalog Catalog Quantity of NO-NC standard Number Ref. Weight Quantity of Ref. MC3E 1-5NNumber separated circuits 1NO-NC (g) 39.5 (1) (1)3 D310020 Contact Contact separated circuits Contact Number Number Number Number separated circuits separated circuits Number (g) (g) (g) (1) (1) Number 39.5 3 3 3 lowstandard levelMC3E MC3E 1-5NBS MC3E 1-5N D310020 D310020 39.5 E310021 39.5 1-5N 1 1 1 standard 1 1 2 1 1 12 2 1 2 21 1 1 1 1 39.5 standardMC3E 3 3 MC3E 1-5N D310020 standard 1-5N D310020 39.5 level MC3E 1-5NBS E310021 39.5 45.7 3 3 3 lowlow level MC3E 1-9NBS low level F310022 39.5 MC3E 1-5NBS E310021 39.5 33 3 MC3E 1-5NBSE310021 low low level MC3E 1-5NBS E310021 39.5 lowlevel level MC3E 1-9NBS F310022 45.7 MC3E 1-5NETF310022 lowwatertight level MC3E L310027 45.740.2 3 3 1-9NBS levelMC3E 33 3 MC3E 1-9NBSF310022 low low level 1-9NBS F310022 45.7 watertight MC3E 1-5NET L310027 40.245.7 40.2 3 watertight MC3E 1-5NET L310027 40.2 watertight 3 3 MC3E 1-5NETL310027 watertight MC3E 1-5NET L310027 40.2 REMOTE SIGNALING WITH INSULATION VOLTAGE UP TO 2200 V AC/DC REMOTE SIGNALING WITH INSULATION VOLTAGE UP TO 2200 V AC/DC Remote Signalling with Insulation Voltage up to 2200 V AC/DC Quantity ofVOLTAGE NO-NC Catalog REMOTE SIGNALING WITH INSULATION VOLTAGE 2200 V AC/DC Ref. REMOTE SIGNALING WITH INSULATION UPUP TOTO 2200 V AC/DC Contact Weight Pack. Number separated circuits Number (g) Quantity of NO-NC Weight Pack. Catalog Ref. Quantity of NO-NC Contact Quantity of 1NO-NC Quantity of NO-NC standard Number Catalog Ref.Ref. Weight Weight Pack. WeightPack. Pack. Catalog Catalog Ref. G310023 MCR3E 1-5NNumber separated circuits 1 (g) 51.7 Contact Contact separated circuits Contact Number Number Number (1) Number Number separated circuits separated circuits Number (g) (g) (g) 11 1 1 1 21 1 1 2 12 2 21 1 1 1 1 P310030 51.7 lowstandard levelMCR3E MCR3E 1-5NBS 51.7 standard 1-5N MCR3E 1-5N G310023 G310023 51.7 G310023 51.7 standardMCR3E MCR3E 1-5NG310023 standard 1-5N 51.7 lowlevel level MC3RE 1-5NBS P310030 51.7 H310024 51.7 low MCR3E 1-9NBSP310030 58.0 low level MCR3E 1-5NBS P310030 51.7 MCR3E 1-5NBSP310030 low low levellevelMCR3E 1-5NBS 51.7 low level MCR3E MCR3E 1-9NBS H310024 58.0 Q31003158.0 1-5NETH310024 52.5 lowwatertight level MCR3E 1-9NBS H310024 58.0 levelMCR3E MCR3E 1-9NBSH310024 low low level 1-9NBS watertight MCR3E 1-5NET Q310031 52.558.0 watertight MCR3E 1-5NET Q310031 52.5 Q310031 52.5 watertight MCR3E 1-5NETQ310031 watertight MCR3E 1-5NET 52.5 1 11 1 1 1 11 1 1 1 1 1 11 1 1 1 1 REMOTE SIGNALLING WITH INSULATION VOLTAGE UP TO 6000 V AC/DC REMOTE SIGNALLING WITH INSULATION VOLTAGE UP TO 6000 V AC/DC REMOTE SIGNALLING WITH INSULATION VOLTAGE 6000 V AC/DC REMOTE SIGNALLING WITH INSULATION VOLTAGE UPUP TOTO 6000 V AC/DC of NO-NC Remote Signalling with Insulation Voltage Quantity up to 6000 V AC/DC Contact Catalog Ref. Weight Pack. Number separated circuits Number (g) Quantity of NO-NC Weight Pack. Catalog Ref. Quantity ofofNO-NC Contact Quantity NO-NC Catalog Ref. Weight Pack. Quantity of 1NO-NC Weight Pack. Catalog Catalog Ref. Weight low level Number J310025 1 MC2R3E 1-5NBS Ref. separated circuits 64.0 Pack. (g)(g) Contact Contact separated circuits Contact Number Number Number Number (1) Number separated circuits separated circuits Number (g) Number (g) 1 1 1 1 1 2 1 1 1 2 2 Electrical 2 2 1 N31002964.0 MC2R3E 1-5NETJ310025 lowwatertight level 64.8 1 11 MC2R3E 1-5NBS low level MC2R3E 1-5NBS J310025 64.0 low low levellevelMC2R3E J310025 64.0 MC2R3E 1-5NBSJ310025 1 1 1-5NBS 64.0 watertightl MC2R3E 1-5NET N310029 64.8 low level K310026 64.8 MC2R3E 1-9NBS watertight 70.3 1 11 N310029 MC2R3E 1-5NET watertight watertight N310029 64.8 MC2R3E 1-5NETN310029 1 1 MC2R3E 1-5NET 64.8 low level MC2R3E 1-9NBS K310026 70.3 low level K310026 1 1 MC2R3E 1-9NBS 70.3 diagram of each microswitch circuit low low levellevelMC2R3E K310026 70.3 MC2R3E 1-9NBSK310026 1 1 1-9NBS 70.3 All of these signalling Electrical diagram of microswitch circuit Electrical diagram ofeach each microswitch circuit Electrical diagram each microswitch circuit Electrical diagram of of each microswitch circuit hand resettable and systems are fitted with these signalling systems C All ofsilver-plated All of these signalling systems are are had 3-terminal microswitch All of these signalling systems are 2 All of these signalling systems are 1 resettable and fitted with silver-plated 3hand resettable and fitted with NC C, NO and NC. hand resettable and fitted with hand resettable and fitted with C terminal microswitch C, NO and NC. 3-terminal microswitch 2 1 Csilver-plated The terminal istheon themicroswitch top and 3-terminal silver-plated silver-plated The CCterminal is on topmicroswitch and connection NC NO2 42 C 1C, NO 1 and NC.3-terminal connection isNC. made 6.35 mm NCNC is via 6.35 mm clipsvia except for waterC,made NO and C, NO and NC. C terminal is on the top and NO 4Blown fluse The clips except for watertight models tight models whose clips are 4.8 mm wideand The C terminal is on the top The C terminal is on the top and NONO 4 4 connection is made via 6.35 mm Microswitch OFF whose clips are mmvia wide. connection is 4.8 made 6.35 Blown fluse connection via 6.35 mm mm except is for made watertight models Blown Blown flusefluse clips except for watertight models clipsclips except for watertight models Microswitch OFF whose clips are 4.8 mm wide. Microswitch Microswitch OFFOFF three main holder axes. whose wide. whose clipsclips are are 4.8 4.8 mm mm wide. C 2 1 NC C 2 1 C NC NO2 42 C 1 1 NCNC NONon-blown fluse NO4NO 4 4 Microswitch ON NOTE (2): The 26.4 dimension is the same Non-blown fluse Non-blown Non-blown flusefluse with 1 or 2 separated circuits NO-NC. Microswitch ON NOTE (2): The 26.4 dimension is the same Microswitch Microswitch ON NOTE (2): The 26.4 dimension is same circuits Tests with sine vibrations carried out atthe ambient with scanning ofON the NOTE (2): The 26.4 dimension is the same NOTE (2): The 26.4 dimension is the same with 1 or 2 separated NO-NC. with 1 or 2 separated circuits NO-NC. Spectrum: segment (2 to 16 NO-NC. Hz) x holder = 5 mm with 21stseparated circuits with 1 with or1 sine 2orseparated circuits NO-NC. Tests vibrations carried out at ambient withconstant scanning oftrip the three main axes.peak. Tests Spectrum: with sine1stvibrations carried out attrip ambient with scanning ofmm thepeak. three main holder axes. nd Exponential scanning speed: 1 octave per minute. 2 segment (16 toout 250 constant acceleration = 5three gmain peak. segment (2 to 16 Hz)carried constant X = 5 of sine vibrations out at ambient with ofγthe main holder axes. TestsTests withwith sine vibrations carried at Hz) ambient scanning the three holder axes. Spectrum: 1st2ndsegment (2toto 16 Hz) constant trip with x scanning =γ5+mm peak. Duration: (16 250 Hz) constant acceleration 5 g peak st st segment Exponential scanning speed :51mm octave per minute.2 hours per axis. Spectrum: 1 segment (2 to 16 Hz) constant trip x = peak. Spectrum: 1 segment (2 to 16 Hz) constant trip x = 5 mm peak. nd 2 ndsegment (16 to 250 Hz) constant acceleration γ = 5 g peak. ndInc.-230 Ryan Way, South 2 hours per axis. Courtesy of Steven Engineering, Francisco, CA 94080-6370-Main (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com segment to Duration: 250 Hz) constant acceleration g peak. 2 2 segment (16(16 to 250 Hz)San constant acceleration γ = γOffice: 5=g5peak. Exponential scanning speed : 1 octave J 424 12 per minute. Exponential scanning speed : 1 octave per minute. Exponential scanning speed : 1 octave per minute. Duration: 2 hours per axis. 424 Duration: 2 hours axis. Duration: 2 hours per per axis. 424424