EBS ETAP Central Battery Systems The ETAP EBS range provides central battery systems for emergency lighting installations, ranging from small to large building projects and from new projects or renovation to standard lighting and specific emergency lighting. EBS products meet all safety, legal and functional requirements. With the EBS system, ETAP provides a full central battery product portfolio which complements its extensive range of high-quality lighting, ­emergency lighting and central monitoring systems. In addition to standard project requirements, central battery systems are very well suited to cover a number of special demands: Strong illumination requirements: in high risk industrial environments where a very high level of illumination must be provided to ensure optimum safety. ETAP | EBS Refurbishment of existing installations: re-use of installed wiring is the key driver. Accessibility issues as often found in production areas, market halls, and sport event areas, or in clean rooms or white rooms. EBS covers your emergency lightings needs Aesthetic integration: in buildings and sites with an architectural concept where escape route and anti-panic lighting is completely integrated into the normal functional lighting. Extended autonomy: a longer autonomy may be necessary in certain hospitals or elderly homes where periods of more than 3 hours of emergency back up are required. Extreme temperature conditions as in open car parks, outside emergency escape routes and cold stores or freezers. The batteries need to be well protected to ensure proper operation under all circumstances. EBS | ETAP The ETAP central battery system range consists of various products to meet the specific needs of each application: EBS Static EBS Superior EBS Static's configuration is pre-defined at the With EBS Superior a new concept of central emer- beginning of a project, based on the specific gency lighting is introduced. It is based on decen- needs. The number of non-maintained and main- tralised intelligence, which means different power tained output circuits and the external switching lines and local emergency circuits are managed possibilities of the latter are pre-customised. The locally. The central source itself can be imple- EBS Static is easy to install and can be commis- mented as battery supply, generator or secondary sioned effortlessly. emergency net supply. Using the EBS Superior a significant reduction in cabling complexity can be EBS Dynamic achieved. EBS Dynamic is a flexible system that can be adapted to the changing needs of a building. It can be extended to manage and operate up to 132 output circuits which can all be easily programmed for the different modes of operation. Predefined systems For buildings requiring limited configuration needs, a number of predefined systems are available. These configurations are readily available and are shipped at short notice. EBS Group EBS Dynamic Light To provide emergency lighting in a small area for Buildings that do not require more then 21 kWh which an energy capacity of 1.5 kWh is sufficient, and need a maximum of 44 output circuits can be ETAP has the EBS Group. The EBS GROUP is an easy equipped with an EBS Dynamic Light system. to install configuration which is ideally suited for small to medium sized building projects. ETAP | EBS The EBS range EBS Static EBS Dynamic EBS Superior ßsimple commissioning ßflexible ßdecentralised intelligence ßno on site configuration ßconfigurable on site ßreduced cabling EBS Group EBS Dynamic Light ßmedium-sized projects ßmax. 44 output circuits ßmax 1.5 kWh ßmax 21 kWh EBS | ETAP Complete solutions With the ETAP centrally supplied systems and our extensive range of emergency and general lighting luminaires, we provide an optimised solution for each application. We guarantee seamless integration of all components, and an easy installation and commissioning. Pre-sales and post-sales assistance Starting from your defined escape route and fire contingency set up, ETAP will guide you throughout the whole emergency lighting project, from concept to implementation. Detailed lighting schemes and system dimensioning can be provided in the study phase. We then work out a detailed quote and assist you during the installation and commissioning. Once the system is up and running, we remain at your service for further assistance and troubleshooting. System integrity under control Using addressable surveillance modules in the emergency lighting luminaires and in the luminaires for general lighting purposes that are part of the emergency lighting, malfunctions of the luminaires can be located and visualised on the integrated LCD display, or transferred to a PC This allows operators and maintenance personnel to quickly and easily ensure emergency lighting ­system integrity. ETAP | EBS EBS properties & advantages Features Benefits System Powerful management capabilities All EBS systems contain a powerful yet easy to use control interface that monitors the normal power ­supply, operates the emergency output circuits and manages the periodic testing schemes of the entire installation. All systems Easy to use and intuitive control tools All ETAP systems are fitted with monitoring features for the electrical circuits, allowing individual luminaires to be monitored. They are visualised on the EBS control panel or a customised surveillance program on PC. All systems Simple configuration When using the addressable FLEX surveillance modules, maintained or non-maintained and switched maintained luminaires can be mixed in the same circuit, thus reducing the number of circuits needed to supply emergency energy to each zone. All systems High flexibility The ETAP EBS range can be customised to the needs of any building or site. Expanding or adapting the system to future changes at a later stage is easily done . EBS Dynamic EBS Superior Off the shelf availability Predefined configurations with a preset number of output circuits and offering a capacity up to 21 kWh, are available immediately. EBS Group EBS Dynamic Light Robust system architecture The EBS Superior system combines decentralised ­intelligence with centralised power management. The system vulnerability is thus minimised. EBS Superior Multi power sourcing The EBS Superior system is designed to operate with multiple power sources: battery supply, emergency generator or secondary mains supply. EBS Superior EBS | ETAP EBS ßComplete solutions ßPre-sales and post-sales assistance ßSystem integrity under control ßPowerful management capabilities ßEasy to use and intuitive control tools ßSimple configuration ßHigh flexibility ßOff the shelf availability ßRobust system architecture ßMulti power sourcing ETAP NV ß Antwerpsesteenweg 130 ß B-2390 Malle ß België ß Tel. 03 310 02 11 ß Fax 03 311 61 42 ß e-mail: info.be@etaplighting.com ETAP Lighting, U.K. Branch ß Unit A ß Hamilton Close ß Houndmills ß Basingstoke ß Hampshire RG21 6YT Tel. +44 (0)1256-818818 ß Fax +44 (0)1256-363358 ß e-mail: enquiries@etaplighting.com ETAP Oficinas centrales ß c/ Mártires Concepcionistas, 3 - 1°D ß 28006 - Madrid ß Tel.: +34 (0)91 402 29 17 ß Fax: +34 (0)91 402 89 16 ETAP Delegación Cataluña ß c/ Comte d’Urgell, 153-E°2a ß 08036 - Barcelona ß Tel./Fax +34 (0)93 451 71 89 ETAP Delegación Norte ß c/ Correo, 11 ß 48005 Bilbao ß Tel. +34 (0)94 415 05 16 ß Fax + 34 (0)94 415 05 21 e-mail: info.es@etaplighting.com www.etaplighting.com 07/07 8011918/008E/0 — Information is provided for guidances only and we reserve the right to change details, as the result of technical development, without prior notice. ETAP Battery System EBS SYSTEM CHARACTERISTICS AND STRUCTURE EBS Static, EBS Group, EBS Dynamic, EBS Dynamic Light Control central Luminaire switching capability per circuit Back-up power supply battery Location of back-up power supply near the control unit Remote maintenance EBS control panel 1 Circuit switching module KCUUE4/220 module 2 Luminaire switching module KCLSM module 3 Communication with GBS LON® Subdistributor cabling two-wire technique EBS MODULE* FOR CONTROL OF STAND-ALONE LUMINAIRES KCADB01 Typ KCFLEX1 To be used with Static, Dynamic, Dynamic Light, Group, Superior Static, Dynamic, Dynamic Light, Group Functionality luminaire control luminaire control and flex technology Address setting rotary coding switch rotary coding switch Max. number of luminaires per circuit 16 16 Back-up power source battery battery (mixed operation in 1 circuit) Switchable with integrated switching relay Voltage 230V / 24V 230V Electronic options K1, K2, K3, K4, K5, K6, K9 luminaire code + C1 luminaire code + C2 * only to be used in combination with electronic ballast 6| WWW.ETAPLIGHTING.COM EBS Superior decentralised stand-alone luminaires battery, emergency generating set, 2nd mains supply independent of control unit via telephone or Internet LON® of EIB® single-wire technique 1 EBS control panel Superior 2 KCSKM module 3 Luminaire switching module KCIOM module 4 Monitoring and control module of the charger KCCMC module KCFLEX2 KCFLEX3 Superior Superior luminaire control and flex technology luminaire control and flex technology (mixed operation in 1 circuit) (gemengde schakeling in 1 kring) rotary coding switch rotary coding switch or automatic addressing 20 20 battery battery, emergency generating set, 2nd mains supply with integrated switching relay for EBS control panel Superior 230V 230V upon request upon request ETAP |7 EBS Technical information 2| WWW.ETAPLIGHTING.COM ETAP central battery system EBS Central emergency lighting can offer a suitable solution in specific situations. Think, for example, of the renovation of existing installations, industrial environments with high light levels, or architectural buildings where the escape route and anti-panic lighting is fully integrated into the lighting system. A central battery may also be indicated where the emergency lighting is not readily accessible or where evacuation takes more time and a long duration is desirable. Emergency power supply devices Electronics cabinet Charging and charge preservation device Switching gear for maintained and non-maintained lighting Control and monitoring device Central battery Luminaires: In all ETAP series (K1, K2, K3, K4, K5, K6, K8 and K9) you can find versions for central power suppy. These luminaires can have the option to be equiped with a module for central control. With LED luminaires it provides monitoring of the electronics, with luminaires with another lamp it provides control of the light source and the electronics. For detailed information please contact your ETAP expert. ETAP |3 EBS Product overview EBS Static Fully automatic, processor controlled monitoring system 19-inch modular technique Steel plate free-standing cabinet Freely programmable for maintained or non-maintained mode Built-in freely selectable individual luminaire or circuit monitoring Central monitoring, also for substations Free programming of all system and customer data possible via PC Individual luminaire monitoring with location indicated in plain text Internal and external bus system Integrated monitoring book (according to EN 50172) for tests and events over a period of more than 2 years Automatic hardware detection, also for retrofitted series connections at the end of the electrical circuit EBS Static EBS Group EBS Group Fully automatic, processor controlled monitoring system 19-inch mounting technique Steel plate free-standing cabinet Individually switchable output circuits with free programming for maintained and non-maintained mode, switched maintained light and stairwell lighting circuit Mixed operation of all types of system modes within one circuit (option) Built-in freely selectable individual luminaire or circuit monitoring Free programming of all system and customer data possible via PC Integrated monitoring book (according to EN 50172) for tests and events over a period of more than 2 years Individual luminaire monitoring with location indication in plain text EBS Dynamic Fully automatic, processor controlled monitoring system 19” mounting technique on swivel frame Steel plate free-standing cabinet with transparent door Individually switchable output circuits with free programming for maintained and non-maintained mode, switched maintained light and stairwell lighting circuit (option) Built-in freely selectable individual luminaire or circuit monitoring Central monitoring, also for substations Free programming of all system and customer data possible via PC Individual luminaire monitoring with location indication in plain text Selection table EBS Static EBS Group Connecting capacity Unlimited 1500 W / 1 h, 500 W / 3 h Number of output circuits Unlimited 4 / 8 / 12 / 16 / 20 Subdistributor Possible DC voltage* 24V / 216V 216V Modular module Mounting of series connections for the lighting circuit Output circuits Fixed wired (maintained/non-maintained) Programmable Optional FLEX technology** Circuit monitoring Included Included Individual luminaire monitoring Optional 1 Included 1 Optional Visualisation Device connection Availability On demand From stock Diagram Page 6 Page 8 * other voltages on demand 1 monitoring module in luminaires required ** mixed operation in the output circuit EBS Dynamic 4| WWW.ETAPLIGHTING.COM EBS Mixed operation of all types of system modes within one circuit Internal and external bus system Integrated monitoring book (according to EN 50172) for tests and events over a period of more than 2 years Automatic hardware detection, also for retrofitted series connections at the end of the electrical circuit EBS Dynamic Light Fully automatic, processor controlled monitoring system 19” mounting technique Steel plate free-standing cabinet with or without control panel cover Individually switchable output circuits with free programming for maintained and non-maintained lighting, switched maintained light and stairwell lighting Built-in freely selectable individual luminaire or circuit monitoring Free programming of all system and customer data possible via PC Individual luminaire monitoring with location indication in plain text Integrated monitoring book (according to EN 50172) for tests and events over a period of more than 2 years EBS Superior Fully automatic, processor controlled monitoring system Modular technique on DIN rail Steel plate free-standing cabinet Compactly structured central unit and substations Mixed operation of all types of system modes within one circuit (option) Programming of each individual luminaire via the master unit Freely selectable power source (battery, emergency power supply, 2nd network) Individual luminaire monitoring for DC and AC mains Built-in freely selectable individual luminaire or circuit monitoring Free programming of all system and customer data possible via PC Single-wire technique for subdistributors High level of reliability through use of intelligent substations with submaster for independent operation Integrated monitoring book (according to EN 50172) for tests and events over a period of more than 2 years Remote maintenance via Internet or telephone Luminaire monitoring with location indication in plain text EBS Dynamic EBS Dynamic Light 21.000 W / 1 h, 7.000 W / 3 h Unlimited Unlimited 20 / 32 / 44 Unlimited Possible 216V 216V 216V Modular module Modular module DIN rail Programmable Programmable Programmable Optional Optional Included Included Included Included 1 Included 1 Included 1 Optional Optional Optional Included Included On demand From stock On demand Page 10 Page 12 Page 14 ETAP EBS Superior EBS Superior Unlimited Possible EBS Dynamic Light |5 EBS Static EBS Static series connections EBS Static contains all necessary and prescribed notification and monitoring devices. All switching, charging and monitoring devices are accommodated in common housing. The consumer output circuits are located in a separate housing section. It is also possible to incorporate a hermetically sealed battery compartment. EBS Static basically comprises the following series connections: - charging and charge preservation device with IU diagram - switching gear for maintained (ML) and non-maintained (NL) lighting - consumer output circuits for ML and NL mounted in a separate housing section, with a Neozed, Diazed or LS switch - control and monitoring device p. 16 - optional auxiliary devices - device and battery cabinet p. 19 Auxiliary devices for EBS Static Components - Network monitoring in subdistributor (UV) p. 20 Options - Transmission and reception unit for individual luminaire monitoring p. 21 - Individual luminaire monitoring module p. 21 basic flex module for mixed operation in the output circuit (flex control to be provided) - Automatic staircase switch (inverter to be provided) p. 22 - Fan control p. 23 time delayed with contactor and motor protection relay with fan with explosion proof fan - Air flow control unit p. 23 - Fuse distributor p. 23 - Subdistributor (SD) module cabinets without functionality maintenance p. 23 module cabinets with 30 minute functionality maintenance (E30) p. 24 - Annunciator panel p. 25 with back-up battery without back-up battery - Printer for operating status notifications and test reports p. 25 parallel Centronix interface printer without take-up spool printer with take-up spool - Telephone modem 6| p. 26 - Temperature monitoring of battery with indication in display p. 26 - Temperature controlled charging p. 26 - Subdistributor power failure notification p. 26 - Earth leakage surveillance p. 26 - External phase selector switch p. 27 - Test software with ECM interface p. 18 WWW.ETAPLIGHTING.COM Installation diagram EBS Static For subdistributor with bus connection, please note that the maximum length of the bus is 1000 m. The bus can be wired in a series or in a star configuration (max. 6 star points) ETAP |7 EBS Group EBS Group series connections Group power supply EBS Group is supplied standard with a maintenance-free sealed OGiV battery with a 5-year design life conform to Eurobat. It contains all necessary and prescribed notification and monitoring devices. The maximum connecting capacity is 1500 W/1h or 500 W/3 h and is available with up to 20 output circuits. EBS Group basically comprises the following series connections: - electronics cabinet - charging and charge preservation device with IU diagram - series connection for the lighting circuit KCUUE4/220 p. 20 - control and monitoring device: EBS Control Panel p. 16 - optional auxiliary devices - combi housing with battery compartment p. 19 - maintenance-free sealed OGiV battery (5-year design life conformto Eurobat) p. 27 Auxiliary devices for EBS Group Components - Network monitoring in subdistributor (UV) p. 20 Options - Module for individual luminaire monitoring p. 21 basic flex module for mixed operation in the output circuit (flex control to be provided) - Monitoring module p. 22 - Remote control panel for the bus p. 25 - Notification panel p. 25 with back-up battery without back-up battery - Printer for operating status notifications and test reports p. 25 parallel Centronix interface printer without take-up spool printer with take-up spool 8| - Temperature monitoring of battery with indication in display p. 26 - Test software with interface p. 18 WWW.ETAPLIGHTING.COM Installation diagram ETAP EBS Group |9 EBS Dynamic EBS Dynamic series connections EBS Dynamic contains all necessary and prescribed notification and monitoring devices. EBS Dynamic basically comprises the following series connections: - electronics cabinet with swivel frame and transparent door p. 19 - charging and charge preservation device with IU diagram p. 19 - series connection for the lighting circuit p. 20 - control and monitoring device: EBS Control Panel p. 16 - optional auxiliary devices - battery housing p. 19 Auxiliary devices for EBS Dynamic Components - Network monitoring in subdistributor (UV) p. 20 Options - Individual luminaire monitoring module p. 21 basic flex module for mixed operation in the output circuit (flex control to be provided) - Automatic staircase switch (inverter to be provided) p. 22 - Monitoring module for light switch position p. 22 - Fan control p. 23 with contactor and motor protection relay with fan with explosion proof fan - Air flow control unit p. 23 - Subdistributor module cabinets without functionality maintenance p. 23 module cabinets with 30 minute functionality maintenance (E30) p. 24 compact - Remote control panel for the bus p. 25 - Notification panel p. 25 with back-up battery without back-up battery - Printer for operating status notifications and test reports p. 25 parallel Centronix interface printer without take-up spool printer with take-up spool 10 | - LON module p. 26 - Telephone modem p. 26 - Temperature monitoring of battery with indication in display p. 26 - Temperature controlled charging p. 26 - Subdistributor power failure notification p. 26 - Earth leakage surveillance p. 26 - External phase selector switch p. 27 - Test software with interface p. 18 WWW.ETAPLIGHTING.COM Installation diagram EBS Dynamic For subdistributor with bus connection, please note that the maximum length of the bus is 1000 m. The bus can be wired in series or in a star configuration (max. 6 star points) ETAP | 11 EBS Dynamic Light EBS Dynamic Light series connections The standard version of EBS Dynamic Light is available from stock and can therefore be used in projects at very short notice. It contains all necessary and prescribed notification and monitoring devices. EBS Dynamic Light basically comprises the following series connections: - electronics cabinet with control panel cover - charging and charge preservation device with IU diagram - series connection for the lighting circuit KCUUE4/220 for a total of 20, 32 or 44 circuits p. 20 - control and monitoring device: EBS Control Panel p. 16 - monitoring module for light switch position p. 22 - optional auxiliary devices - combi housing with battery compartment p. 19 Auxiliary devices for EBS Dynamic Light Components - Network monitoring in subdistributor (UV) p. 20 Options - Module for individual luminaire monitoring p. 21 basic - Remote control panel for the bus p. 25 - Notification panel p. 25 with back-up battery without back-up battery - Printer for operating status notifications and test reports p. 25 parallel Centronix interface printer without take-up spool printer with take-up spool - LON module 12 | - Telephone modem p. 26 - Temperature monitoring of battery with indication in display p. 26 - External phase selector switch p. 27 - Test software with interface p. 18 WWW.ETAPLIGHTING.COM Installation diagram ETAP EBS Dynamic Light | 13 EBS Superior EBS Superior series connections EBS Superior is a modular and therefore highly compact emergency lighting system. It contains all necessary and prescribed notification and monitoring devices. EBS Superior basically comprises the following series connections: - electronics cabinet with transparent door p. 19 - charging and charge preservation device with IU diagram p. 19 - series connection for the lighting circuit KCSKM p. 20 - control and monitoring device: EBS Control Panel Superior p. 17 - optional auxiliary devices - battery housing p. 19 Auxiliary devices for EBS Superior Components - Network monitoring in subdistributor p. 20 - Control/monitoring of the charging device with CMC module p. 20 Options - Module for individual luminaire monitoring p. 21 basic flex module for mixed operation in the output circuit - Monitoring module for light switch position p. 22 - Redundant battery management and charge bus - LAN Ethernet interface - Test software with interface 14 | p. 18 WWW.ETAPLIGHTING.COM Installation diagram ETAP EBS Superior | 15 EBS Control Interface EBS Control Interface Control and monitoring device: EBS Control Panel Communication interface for - EBS Static - EBS Dynamic - EBS Dynamic Light - EBS Group General - Central unit in 19” technique - Simple maintenance by plug and socket connections on all modules - If the deep discharge voltage falls below the threshold, the current is reduced to a few mA - All subunits have decentralised intelligence Operation - Foil keyboard - Data protection via password and factory settings via PC protocol - Flexible programming of switching circuits - Configuration of all parameters via PC with service software - Output circuits are individually programmable as maintained or non-maintained lighting or switched maintained lighting (on EBS Static, only the switchover devices are programmable) - Automatic detection of connected devices and units - Easy retrofitting of output circuits or additional options - 4 integrated timers for control of the maintained lighting circuits - Staircase lighting circuit (1 to 15 minutes) - Continuous or on-demand printing of messages Testing - Freely programmable, automatic function test - Duration test with evaluation of battery capacity - DC isolation monitoring is standard - Battery monitoring with freely selectable taps - Battery voltage monitoring: max/min - Charge current monitoring: max/min Indicators - Illuminated plain text display, 4 lines of 16 characters each - Charge and discharge current in display - Maintained/non-maintained lighting currents are displayed as effective values - Voltage of all 3 power supply phases is indicated in the display - Buffer memory for messages and function tests over 2-year period - Documentation of all factory settings via PC protocol - Log of function tests in internal memory - Log of duration tests in internal memory Control - Adjustable fan run-on - Adjustable fan interval Connection - Easy connection of subunits via BUS - Standard serial RS232 interface for connection of a PC for data acquisition - Connection for temperature sensor for monitoring and display of battery temperature - Central process control interface: all messages via opening/closing contacts - High reliability against interference through potential separation of the processor part - Internal communication via CAN-BUS for high reliability against interference. The entire bus system is isolated via opto-couplers. - All data on the BUS are available for evaluation and control 16 | WWW.ETAPLIGHTING.COM Control and monitoring device: EBS Control Panel Superior EBS Control Interface Communication interface for - EBS Superior General - Microprocessor controlled - Visualisation of the entire system via built-in or connected PC - Optional use of the master unit in substations as submaster system Operation - Foil keyboard - Data protection via password and factory settings via PC protocol - Easy parameterisation via PC with service software or via menu keys - Quick access to frequently used functions via programmable function keys - Programming of each individual luminaire possible - Remote maintenance via telephone or Internet - Automatic detection of connected devices and units - Easy retrofitting of output circuits or additional options - 4 integrated timers for control of the maintained lighting circuits - Staircase light circuit (1 to 15 minutes) Testing - Automatic function and duration tests Indicators - Operating status messages via LED - All messages are indicated as plain text - Illuminated plain text display, 4 lines of 20 characters each - Buffer memory for messages and function tests over 2-year period Control - Adjustable fan run-on - Adjustable fan interval Connection - USB 2.0 interface for connection of a PC - Parallel Centronic-printer interface (optional) - 8 digital inputs for connection of voltage free contacts EBS Mixed Operation FLEX technique Only two instead of six output circuits for maintained lighting, non-maintained lighting and switched maintained lighting modes. Fewer cables Reduced fire load Decreased installation costs Allocation of individual luminaires can be modified at all times Simplified project management ETAP | 17 EBS Visualisation Visualisation ETAP Central Battery Manager – ECM The ECM visualisation system allows central monitoring and operation of EBS emergency lighting systems with the following functions: - Visual representation of all system information - Display of all luminaire or circuits with indication of the configuration - Display of all individual circuit currents - Display of faults with detailed fault data - Display of defective luminaires - Display, storage or print-out of the test logbook - System overview with free naming for all subdistributors, circuits and luminaires - Integrated service module for programming of the system and output circuits - Remote system control: system ON/OFF, maintained luminaires ON/OFF, test initiation, circuit calibration Configuration - CD-ROM incl. CAN dongle / bus interface to be provided - with PC desktop version / bus interface to be provided - Industrial PC built into EBS Dynamic - with built-in laptop 18 | WWW.ETAPLIGHTING.COM Central Battery System – Technical Specifications EBS Technical Specifications EBS Static, EBS Dynamic, EBS Dynamic Light, EBS Superior Mains connection: Supply voltage: Form factor: Radio interference suppression: Enclosure: Protection class: Noise: Perm. ambient temperature: Residual hum: Paint: Door: single phase 230 V / 50 Hz or (depending on the output) three-phase 400 V / 50 Hz UN ±10 % approx. 1.1 with three-phase current / approx. 1.4 with alternating current N (VDE 0875) IP21 I max. 60 dB (A), measured at 1 m distance 0° to 40°C at max. installation height of 1000 m above sea level <5 % with parallel-connected battery RAL 7032 right-hinged / max. opening angle: 180° Dimensions Dimensions H x W x D (mm) Battery compartment dimensions H x W x D (mm) Max. number of output circuits D01/D02 Max. number of series connections for the lighting circuit Max. number of SK modules Device cabinet 1200 x 600 x 430 30 1400 x 800 x 600 57 1800 x 600 x 600 45 5 1800 x 600 x 400 10 1800 x 600 x 400 15 1800 x 800 x 600 79 11* 1800 x 800 x 600 79 22* 1800 x 800 x 600 79 33* ** 35 11* Combi housing 1800 x 800 x 600 600 x 750 x 555 10 Battery housing 1200 x 600 x 430 990 x 570 x 360° 1400 x 600 x 600 1190 x 555 x 555° 1400 x 800 x 600 1190 x 750 x 555° 1800 x 600 x 600 1590 x 555 x 555° 1800 x 800 x 600 1590 x 750 x 555° 2000 x 900 x 600 1790 x 850 x 555° 1800 x 800 x 800 1590 x 755 x 750° 1800 x 1000 x 800 1590 x 950 x 750° * Optionally also available with 450 mm depth ** Additional distributor box is recommended ° Each housing is standard supplied with 2 grid floors for the installation of batteries (capacity 250 kg) OPTION: housing base 100 – 400 mm additional grid floor EBS Group Mains connection: Enclosure: Charger: Battery: Bridging duration: Paint: Door: Dimensions (HxWxD): ETAP 230 V / 50 Hz IP21 1.5 A Maintenance-free sealed lead battery 18 x 12 V / 12 Ah 1500 W / 1h – 500 W / 3 h RAL 7032 right-hinged / max. opening angle: 180° 1200 x 600 x 430 mm | 19 EBS Technical Specifications Serial connection for lighting circuit, KCUUE4/220 for EBS Group, EBS Dynamic, EBS Dynamic Light Art. No.: KCUUE4/220 Model: 19” module Number of outputs: 4 suitable for: circuit or individual luminaire monitoring mixed individual luminaire and circuit monitoring operation Luminaires: 20 per output – 16 per output (with individual monitoring) Switching from circuit to Individual luminaire monitoring possible without hardware changes Fuse: 6.3 A (2-pole) Max. switching capacity: relay 6 A 220 V DC / circuit Dimensions (HxWxD): 129 x 35 x 170 mm for EBS Superior Art. No.: Model: Number of outputs: suitable for: Used in: Connection to master unit: Luminaires: Switch commands: Fuse: Max. switching capacity: Dimensions (HxWxD): Serial connection for lighting circuit, KCSKM EBS Components Functionality and technical specifications - components Mains monitoring module Functionality: Art. No.: Supply voltage: Tripping value: Power input: Contacts: Mounting: Display: Dimensions (HxWxD): Mains monitoring module KCWMU KCSKM DIN rail mounting 4 circuit or individual luminaire monitoring mixed individual luminaire and circuit monitoring operation protection of a single fire compartment main station – substation – individually via 2-wire system bus 20 per output via mains cable 6.3 A (2-pole) 815 W / circuit 90 x 105 x 66 mm (6 TE) Mains monitoring in the case of subdistributors for the detection of undervoltage and mains failure in the single or three-phase mains KCWMU 230/400 V 50 Hz 85% of nominal voltage 3 VA 2 changeover voltage free contacts DIN rail LED ‘OFF’ in case of mains failure 59 x 35 x 59 mm Control and monitoring module of the charge device for EBS Superior Art. No.: Functionality: KCCMC Control and monitoring of the charge device for the Batteries Control and monitoring module of charge device, KCCMC 20 | WWW.ETAPLIGHTING.COM Functionality and technical specifications - options EBS Options Transmission and reception unit for individual luminaire monitoring for EBS Static Functionality: for luminaire and circuit monitoring, built into central System Individual luminaire monitoring module Art. No.: Functionality: Protection class: Input voltage: Ambient temperature: Output range: Dimensions (HxWxD): Art. No.: Functionality: Protection class: Input voltage: Ambient temperature: Output range: Dimensions (HxWxD): Art. No.: Functionality: Protection class: Input voltage: Ambient temperature: Output range: Dimensions (HxWxD): KCADB01 Setting of luminaire addresses via an externally accessible rotary encoding switch IP 20 230 V AC/DC -10°C to +50°C 2 - 120 W 106 x 36 x 24 mm KCFLEX1 for EBS Static, EBS Group, EBS Dynamic KCFLEX2 for EBS Superior Module for individual luminaire monitoring Maintained / non-maintained lighting switch Integrated changeover switch for switched maintained light IP 20 230 V AC/DC -5°C to +50°C 4 - 120 W 165 x 36 x 35 mm KCFLEX3 for EBS Superior Module for individual luminaire monitoring Individual luminaire switching in AC/DC mains via I/O unit (switched maintained light, sML) Setting of luminaire addresses via an externally accessible rotary encoding switch or Programming of maintained lighting (ML) / non-maintained Lighting (NML) via the master unit IP 20 230 V AC/DC -10°C to +50°C 2 - 120 W 137 x 36 x 26 mm Monitoring module KCADB01 Monitoring module KCFLEX1 Monitoring module KCFLEX2 Monitoring module KCFLEX3 Luminaire changeover switch Art. No. Functionality: Input voltage: Protection class: Dimensions (HxWxD): ETAP KCUWE1 (switching capacity: 250 VA) Use of luminaires for general and emergency lighting General lighting: 230 V / 50 Hz Emergency lighting: 180-270 V / AC/DC IP 20 130 x 46 x 31 mm Changeover switch KCUWE1 | 21 EBS Options Distributor changeover switch Art. No.: Functionality: Input voltage: Protection class: Dimensions (HxWxD): KCUWE2 (switching capacity: 250 VA) KCUWE3 (switching capacity: 500 VA) Use of luminaires for general and emergency lighting General lighting: 230 V / 50 Hz Emergency lighting: 180-270 V / AC/DC IP 20 96 x 48 x 50 mm Changeover switch KCUWE2 Automatic staircase switch Functionality: Input voltage: for EBS Static Type: for EBS Dynamic, Dynamic Light Type: Staircase lighting switch (SLS) General lighting: 230 V / 50 Hz AC Emergency lighting: 220 V DC AC/DC multi-function relay without additional inverter Automatic staircase switch (additional inverter required) 200 W inverter for key illumination Light switch position monitoring module for EBS Group, EBS Dynamic, EBS Dynamic Light Functionality: Input channels: Input: Light switch module KCLSM230 Monitoring: art. No.: KCLSM24 art. No.: KCLSM230 art. No.: KCLSM24/230 Max. bus cable length: Switching of output circuits during mains operation via switches/contactors of the general lighting system 16 Assignable to one or more output circuits of a series connection for the lighting circuit, KCUUE4/220 or Flex unit (individual switching) or programmable as staircase lighting switch of emergency luminaires (1 to 15 min.) via voltage free contacts via a 230 V AC external voltage inputs 1-8: 230 V AC external voltage Inputs 9-16: voltage free contacts 100 m Light switch position monitoring module for EBS Superior Functionality: Light switch module KCI0M24 Monitoring: art. No.: KCIOM24 Input channels: Input: Monitoring: art. No.: KCIOM230 Input channels: Input: Light switch module KCI0M230 22 | Max. bus cable length: Switching of output circuits during mains operation via switches/contactors of the general lighting system with LED status indication per input via voltage free contacts 16 Assignable to one or more output circuits of lighting circuit module KCSK module or KCFLEX3 unit (individual switching) or programmable as staircase lighting switch of emergency luminaires (1 to 15 min.) via a 230 V AC external voltage 9 9 x 230 V AC switching input 6 x 230 V AC switching input + mains monitor, 3-phase 8 x 230 V AC switching input + mains monitor, 1-phase 500 m WWW.ETAPLIGHTING.COM Fan control for EBS Static, EBS Dynamic, EBS Dynamic light Type: EBS Options with contactor and motor protection relay with fan with explosion proof fan Air flow control for EBS Static Functionality: Air direction relay Fuse distributor Functionality: Number of output circuits: Decentralised fuse protection of output circuits max. 16 / 24 with fuses D01-D02 or max. 14 / 21 with LS switch 600 x 400 x 250 / 800 x 400 x 250 (mm) Dimensions (HxWxD): Subdistributor module cabinet without functionality maintenance for EBS Static Functionality: Dimensions H x W x D (mm) Changeover device, circuit monitoring, individual luminaire monitoring, bus connection to main device Max. number of fuses Max. number of LS switches 800 x 600 x 250 24 18 1800 x 800 x 400 79 60 for EBS Dynamic Housing: Functionality: Electronics cabinet with lockable door decentralised fuse protection of output circuits 19” rack chassis for lighting circuit module KCUUE220/4 bus connection to main device via 3-wire bus (CAN) easily accessible terminals for the output circuits connection of up to 31 subdistributors for main station: Dimensions H x W x D (mm) Max. number of KUUE220/4 Max. number of output circuits 600 x 400 x 250 5 20 800 x 600 x 250 11 44 1800 x 800 x 450 11 44 1800 x 800 x 450 22 88 1800 x 600 x 450 33 132* * additional distribution cabinet 1800 x 600 x 450 mm required ETAP | 23 EBS Options Subdistributor module cabinet with 30-minute functionality maintenance (E30) for EBS Static Functionality: Dimensions* H x W x D (mm) Changeover device, circuit monitoring, individual luminaire monitoring, bus connection to main device Max. number of output circuits with D01/D02 fuses Max. number of output circuits with LS switches 1000 x 722 x 400 12 18 1150 x 972 x 400 30 30 2050 x 722 x 400 60 72 2050 x 1222 x 400 120 120 * under reserve for EBS Dynamic Housing: Functionality: Subdistributor in E30 for main station: Electronics cabinet in E30 with lockable door decentralised fuse protection of output circuits 19” rack chassis for lighting circuit module KCUUE220/4 bus connection to main device via 3-wire bus (CAN) easily accessible terminals for the output circuits connection of up to 31 subdistributors Max. number of KUUE220/4 Max. number of output circuits 1000 x 722 x 400 5 20 1150 x 872 x 400 11 44 2050 x 1222 x 400 22 88 Dimensions H x W x D (mm) Subdistributor Compact for EBS Dynamic Functionality: Dimensions H x W x D (mm) 24 | incl. integrated lighting circuit modules KCNLE4/220 light switch position monitoring module KCLSM (type upon request, see above) bus interface board easily accessible terminals for the output circuits Number of NLE4/220 plug-in units Number of output circuits 600 x 400 x 250 2 8 600 x 400 x 250 3 12 600 x 400 x 250 4 16 600 x 400 x 250 5 20 800 x 600 x 250 7 28 800 x 600 x 250 9 36 800 x 600 x 250 11 44 WWW.ETAPLIGHTING.COM EBS Options Bus compatible remote control panel for EBS Dynamic and EBS Dynamic Light Art. No.: Functionality: Indications in the display: LED indicators: Supply voltage: Data transmission: Dimensions (HxWxD): KCMTB bus Intelligent annunciator and control panel Remote control of the emergency lighting system Functions identical to those of the EBS Control Panel - switch system ON/OFF - switch maintained luminaires ON/OFF - initiation of function and duration tests - isolation test - LED test - selection of configuration and information menus Use as display unit for substations Indication of battery voltage Indication of charge and discharge current Digital indication of all consumer currents Indication of voltage of all 3 power supply phases Indication of test logbook Indication of luminaire faults Indication of all faults in plain text (4 lines of 16 chars each) Indication of battery temperature (optional) Ready/malfunction Mains operation / battery operation Maintained lighting ON / Non-maintained lighting ON Test mode Deep discharge 220 V DC via 3-wire MTB bus cable: 2 x 2 x 0.8 219 x 185 x 115 mm Remote control panel KCMTB-Bus Annunciator panel Art. No.: Functionality: Signalling device: Protection class: Dimensions (HxWxD): KCMS (with back-up battery) / KCMB (no back-up battery) Indicators: ready, mains operation, battery operation, Series interference Switch: maintained switching range ON/OFF Buzzer with release key IP 20 261 x 150 x 90 mm Notification table Printer for operating status messages and test reports Art. No.: Functionality: KCPSC Written reports in accordance with DIN EN 50172 - all faults and system status changes - end of faults - function and duration test results - all data with date and time Parallel Centronic interface Printer without take-up spool Printer with take-up spool Printer ETAP | 25 EBS Options LON module Functionality: Possible commands: Data provided: LON module Connection of an EBS Dynamic or Dynamic Light System to a LON bus Conversion of system data/commands into LON format System ON/OFF; maintained lighting ON/OFF; start function test; start duration test; reset (abort test) battery voltage; charge current; discharge current; battery temperature; time; various fault messages; various system states; various error messages after function test Telephone modem for EBS Static, EBS Group, EBS Dynamic, Dynamic Light Alarm: 8 permanently programmed messages for EBS Group, EBS Dynamic, EBS Dynamic Light Alarm: permanently programmed messages or plain text on mobile phone, e-mail, radio receiver, fax or PC Temperature monitoring of the battery with indication in display Functionality: Temperature sensor for monitoring the battery temperature with indication in the display Temperature controlled charging Functionality: Charging of the battery as a function of its temperature Subdistributor power failure notification Functionality: Visual indication of a power failure of a subdistributor at the main station Earth leakage surveillance AC Functionality: 26 | Isolation monitoring of IT networks (additional separating transformer required) WWW.ETAPLIGHTING.COM External phase selector switch Functionality: EBS Options Enclosure: Changeover to an intact phase upon failure of one or two phases ISO Output, one-phase Art. No.: Input voltage: Output voltage: Nominal current: Signal contact: KCPSW30 3 x 400 V 230 V 30 A phase failure; no phase Phase selection circuit Output, three-phase Art. No.: Input voltage: Output voltage: Nominal current: Signal contact: KCPSW90 3 x 400 V 3 x 400 V 90 A (3 x 30 A) phase failure; no phase EBS Batteries Batterien OGiV Type of battery * OGi OPzS Model sealed, block enclosed, block enclosed, block Mounting position upright, horizontal upright upright Capacity range in Ah 17-200 25-300 50-300 Nominal voltage in V 12 6/12 6/12 positive elektrode grid grid tubular plates alloy lead-calcium lead-antimony lead-antimony pole screw pole screw pole screw pole elektrolyte AGM vlies fluid fluid housing material ABS SAN SAN plug / valve safety valve plug plug Water refill not possible approx. 2 years approx. 2 years Self-discharge in % per month 3 3 3 Temperature range in °C -10 to +40 -10 to +40 -10 to +40 Ventilation requirement as per DIN 50 272-2 DIN 50 272-2 DIN 50 272-2 Design life as per Eurobat (years) 10-12 12-15 >15 DIN EN 60896-11 DIN EN 60896-11 Battery / cell construction Design life (years) Standard DIN EN 60896-21 & 22 * other batteries upon demand ETAP | 27 The data used in this publication are not binding and subject to change as the result of technological development. 5010794-028E/1 ETAP Lighting, U.K. Branch - Unit 6 – Windsor Business Centre – Vansittart Estate – Windsor - Berkshire SL4 1SE - Tel. +44 (0)1753 829970 - Fax +44 (0)1753 859208 e-mail: enquiries@etaplighting.com - www.etaplighting.com