Doc# 1313 WWW.DLC-LUMISHEET.COM DLC is pound to offer multiple Dimming options for our LED products. From simple control to commercial applications. Our team is eager to help you should you need any assistance. LED Dimming and Controls This documents list dimming options available to dim LED light panels/light bars supplied by DLC for the convenience of customers to select the right dimming options best suit a particular application. Dimming Option - P Pulse Width Modulation (PWM) Dimming Option - M Using top quality Philips pulse width modulation, controlled by 0-10 V DC switches Advantages: • All components UL/cUL Class 2 approved • Smooth dimming (no flickering) Ideal for commercial residential application This option uses magnetic transformers Magnetic Low Voltage Advantages: (MLV) • Less components and simplified configuration • Ready to use wall mount magnetic dimming switch Disadvantage: • May experience flickering at some particular position depending on LED load (typically a minimum 50% load required) Dimming Option - I Ideal for commercial residential application This is a dimming option with a radio frequency remote control and several dimming modes such flashing, fade-in/fade-out (PWN) Advantages: • Plug and play Dimming Option - R (PWM) Ideal for small systems. This is a simple rotary inline dimmer for brightness matching. Ideal for “set &forget” applications 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM Doc# 1313 WWW.DLC-LUMISHEET.COM Dimming Option - P 0-10v LED Dimming Module for 12vdc LED Systems Class 2 Power Unit Outdoor Rated NRTL/C Environmental Ratings PRODUCT OVERVIEW: Symbol Minimum Minimum Unit Operating Ambient Temperature Top -40/-40 +60/+140 °C/°F Storage Ambient Temperature Tst -40/-40 +80/+176 °C/°F illumination settings. Relative Humidity RH - 80 % As with all of Advance's LED drivers, the new Lifetime (failures after 50,000 hours) L50K - 5 % The LED Dimming provides the required dim level to 12 Volt LED lighting systems enabling flexibility to the user to add their own personal touch to the products support such standard features as leaded design, UL and CSA Class 2 rating including inherent short-circuit protection, high power factor, and operation down to –40°C. In addition, the controllers are rated for 50,000+ hours of life and carry A's full five-year warranty. Parameter Electrical Characteristics Parameter 12.0 VDC Efficiency lo >98% typical % 5.0 Max ADC Vo 12.0 VDC - 0-10V (see Technical Requirements) - Output Current Dimming Control • Pulse Width Modulation (PWM) Dimming Unit Vi n Output Voltage DESIGN HIGHLIGHTS: Symbol input Voltage Range Notes: Electrical characteristics at 25°C ambient temperature and at full power. Provides 0-10V Dimming control • Power efficiency Optimization of the usage of the total system power • UL Class 2 Designed for use with any 12V UL Class 2 devices Mechanical Dimensions • UL Outdoor Damp location rated, IP66 Fully potted for moisture resistance 1.35 • Small, compact size Facilitates new, low-profile fixture design 0.99" • ExtremeT low temperature performance (-40°C) Suitable for any outdoor application • Generous high temperature capability 0.15" 5.20" (+60°C ambient; 80°/90°C case rating) Margin flexibility to facilitate fixture design • 5-year warranty offered by the manufacturer Peace of mind for your new products and for end-users... from the industry’s most trusted component maker 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM Doc# 1313 WWW.DLC-LUMISHEET.COM 1. The light output of the LEDs operated by the Dimmable Driver is controlled by DC voltage applied to the control input leads (0-10V DIM purple and gray). 2. The control device must be capable of accepting, or sinking, the DC current flow from the driver. The maximum under any condition is 500 microamps per driver. 3. The control terminals of the driver are isolated from the power lines and are suitable for use as Class II terminals. As many drivers as desired for use with the particular control device may be connected in parallel in a bus configuration. The length of the bus, the wire size of the bus and the number of drivers connected on the bus must be configured so that the DC voltage drop as a function of the resistance of the wire and the control current flowing does not exceed 0.2 volts for dimming controls. For controls used as a minimum/maximum, or hi-lo 2-level application, the maximum DC voltage drop must not exceed 0.5 volt. 4. If the control bus is opened, or if the control device internally opens the control bus under some conditions, the voltage on the control bus will then be a function of the ballast, which is 10V ± 0.5 volt. Maximum light output will be delivered under this condition. 5. If the control bus is shorted either by a mechanical switch in the control or by the circuitry of the control device, or inadvertently in the wiring, the current on the control bus will be 500 microamps per driver maximum. All drivers on the control bus will then operate at minimum light level. 6. As can be determined from the two above items, simple two-level operation of the driver can be achieved by proper usage and application of a simple open/close switch on the control bus with maximum light being achieved when the switch is open and minimum light when the switch is closed. 7. The driver is intended for use with control voltages between 0 (zero) and 10 (ten) VDC. The control equipment must not impose a voltage greater than 11.0-volt peak maximum on the driver control terminals. 8. The DC control voltage should have a maximum peak to peak ripple (low and high frequency ripple) not exceeding 10% of the average VDC. Short-term transient voltage of the control devices must not exceed 14 volts. 9. Control equipment intended to control more than one driver must be capable of sinking the current supplied to the control bus by the maximum number of drivers specified for the control device. At any given level setting it must maintain control bus voltage constant within a range of ±5% as the number of drivers connected to the control bus varies from a minimum of one driver up to the maximum number specified for the control device. 10.D rivers of various ratings (120V, 230V…) may be mixed on the same control system. 11.S ince the control bus is Class II wiring, all control devices that are connected to the power line must have proper isolation between the power line and the control leads. Any control devices that are connected to the power line must have UL approval/ recognition as Class II equipment. *Example only components may not be exactly as show 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM Doc# 1313 WWW.DLC-LUMISHEET.COM Dimming Option - M Dimmable Magnetic Low Volatage Transformers PA-60W(MAG) PA150W(MAG) *Note: The Transformer requires a 50% load if not being used with a dimmer. Do not turn power on before load is connected General This transformer is to be installed in accordance with Article 450 of the National Electric Code. The transformer must be installed in a well-ventilated area free from explosive gases and vapors. Proper operation requires the free flow of air. As this transformer is hard wired , it should only be installed by a qualified electrician. Precautions Before Installing Check the label and ensure the transformer has the proper input voltage, output voltage and wattage for the job. Check the wire marking to ensure they match the wiring diagram on this instruction sheet. Mounting Select a suitable location capable of supporting the weight of the transformer. Use the two keyholes in the transformer case. It is recommended that the transformer be mounted vertically with the wiring compartment pointing down. Input Connections/Grounding Remove the wiring compartment knockouts and install strain reliefs. With power turned off, route the input wires through a strain relief and connect one wire to black and one wire to white. For all wire connections use only UL listed wire nuts and connectors of suitable size and type. The transformer case MUST be grounded in accordance with the N.E.C. Connect the ground wire to the transformer green wire. Output Connections Bring the wires of the light fixture through the other open knockout and connect them to the transformer wires-positive to the red wire and negative to blue wire. Specifications Enclosure • • • • • Enclosure temperature will not exceed 70°C @ 40 °C ambient. Wiring compartment has 2 knockouts sized for 3/4 inch screw cable connectors. The removable cover for the wiring compartment is secured in place by a screw. The enclosure is black powder coated. NEMA 3R Series PA-60W(MAG) PA150W(MAG) Maximum Load 60W 150W Input Voltage 120 V 60 Hz 120 V 60 Hz Output Voltage Full Load 11.5 VDC 11.5 VDC Output Current Full load 4.8 A 12.35 A Input Current Full Load 540mA 1240 mA Open Circuit Volts 12.5 VDC 12.5 VDC Protections Overload Over Current Short Current Overload Over Current Short Current Efficiency 89.20% 85.20% Coil Former Double Section Bobbin Double Section Bobbin Thermal Class B 130 °C B 130 °C Leads Primary PVC 600 V #20 PVC 600 V #18 Leads Secondary PVC 300 V #14 PVC 300 V #12 Dimensions in inches 6.06”(L) x 2.59”(W) x 2.20” (D) 9.06”(L) x 3.06”(W) x 2.81” (D) 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM Certifications ETL for USA and Canada (UL std. 1598, CSA std. C22.2 NO. 66.1) Doc# 1313 WWW.DLC-LUMISHEET.COM Circut Diagram Compatible Dimmers Brand Type Control Watts Lutron Ariadni AYLV-600P Single Pole 450W Lutron Ariadni AYLV-603P 3-Way 450W Lutron Nova NTLV -600 Single Pole 450W Lutron Nova NTLV-1000 Single Pole 800W Lutron Nova NTLV-603P Single Pole/3-Way 450W Lutron Nova NTLV-1003P Single Pole/3-Way 800W Lutron Nova NLV-600 Single Pole 450W Lutron Nova NLV-1000 Single Pole 800W Lutron Ceana CNLV-603P 3-Way 450W Lutron Diva DVLV-103P 3-Way 800W Lutron Diva DVSCLV-103P 3-Way 800W PA-60W (MAG) Auto-Reset Breaker 20 Amp (for150W) 7 Amp(for 60W) Auto-Reset Breaker White Red + Blue Black Input 120 V 60Hz Output 12 VDC 60W / 12 VDC 150W **Please contact us for more options not listed in the above table. Dimensions (inch) PA-150W (MAG) PA-60W (MAG) 2.33" 6.06" 6.56" 2.81" 2.33" 2.81" 9.06" 2.5" 9.88" 3.06" Typical Dimmer Wiring Schematic PA-60W(MAG) PA150W(MAG) Dimmable Magnet Transformer M60L 12DC/M150L 12DC (Max 60W/150W) Input: 120V 60Hz (Black/White) Output: 12VDC Green Blue GND (DC) Red +12 V DC Output White Black Neutral (N) Line Terminate wire for Single pole application Magnetic Low Voltage Dimmer Switch (Not included) Green 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM DLC LED Light Panels Doc# 1313 WWW.DLC-LUMISHEET.COM Dimming Option - I Inline Dimmer with Remote Control Model: DLC-DIM-RF “DLC‐DIM‐RF” is an inline plug‐and‐play dimmer with a radio frequency remote control pad designed for LED lighting applications. It is so tiny that it can be installed anywhere by simply plugging‐in between power adaptor and LED lights. The unit has built‐in static dimming modes, and dynamic control modes such as quick flashing, fading in/fading out, stroking, flickering with speed adjustment etc. 4.5mm 15mm 3.5mm Peak Output Current:6A With RF Remote Control LED LED CONTROLLER Working temperature: -20 ~ 40 °C Supply voltage: 12V DC Output: 1 channel Connection mode: common anode Controller dimension: L35.0 × W15.0 × H4.5mm Remote dimension: L85.9 × W39.6 × H6.9mm Packing size: L123.0 x W90.0 x H13.0mm Net weight: 35g Gross weight: 40g Static power: <0.5W Output current: <6A Output power: 12V < 72W, 24V <144W Frequency of wireless signal: 433M11Z 6.9mm 39.6mm 85.9mm • • • • • • • • • • • • • Dimensions 85.9mm Technical Specifications 5-24V Remote dimensions Controller dimensions Input/Output Specifications (Disconnects) Connect to D.C. 5-24V. LED Power Supply Input DC female: 5.5 x 2.1mm (POWER IN) Connects to LED Lamps (load) Output DC male:5.5 x 2.1mm (POWER OUT) 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM (See next page for more details) Doc# 1313 WWW.DLC-LUMISHEET.COM Instructions Synchronizing Remote Pad One remote pad can control multiple DLC‐DIM‐RF dimming units. For this purpose, it is necessary to synchronize the dimming units with a particular control pad. By factory default, the remote control pad is NOT synchronized to a specific dimming unit. Follow the procedures below to synchronize: 1. Make sure battery (CR2025/CR2032, 3V button battery) is installed. 2. Turn off the power to the dimming unit 3. Press and hold the “LIGHT” button on the remote pad within 3 seconds when powering on the dimming unit. The LED light connected will flash 3 times when the synchronizing process is successful. Troubleshooting: If the remote control does not function, it could be the battery has run out of life, especially when the remote pad was not used for a long time. Exchange the battery and follow the above procedure to synchronize. Descriptions of Remote Control Pad This remote has 11 functions: Turn on/off key. LIGHT BRIGHT + Switch to static color mode from dynamic mode. Modes Table Switch to static color mode from dynamic mode, and change the brightness forward/reverse direction. There are 10 levels. 1 Quick flash 5 Half stroboflash Switch to static mode brightness 100%. 2 Breathing mode 6 Two-thirds stroboflash 50% Switch to static mode brightness 50%. 3 Fading bright and fading out 7 A third stroboflash 25% Switch to static mode brightness 25%. 4 Fading bright and fading dark 8 BRIGHT - 100% MODE + MODE - SPEED + SPEED - Flash Switch to dynamic mode from static color mode, and change the dynamic mode to a forward/ reverse direction. Switch to dynamic mode from static color mode, and change the speed forward/reverse direction, it has 10 levels. Typical Applications ( Not Included ) - With RF Remote Control Peak Output Current 6A + LED LED CONTROLLER + + 5-24V - 12 V DC - Caution: The output voltage of the power supply must match the rated input voltage of the LED light e.g, if the LED light is rated at 12VDC input, connecting a 24VDC output power supply may burn the LED in a few seconds. 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM Doc# 1313 WWW.DLC-LUMISHEET.COM Dimming Option - R Model LN-XDIMMER-1CH-LV A simple rotary style dimmer for manual adjustments or “set and forget” applications. Technical Specification • • • • • • • • • • Output current: <8 A Power output: 12V<96W Working temperature: -20-60 °c Supply voltage: 12V DC optional Output: 1 channel External dimension: L89 Χ W59 Χ H35 mm Packing Size: L96 Χ W64 Χ H65 mm Net weight: 85 g Gross weight: 110g Static power consumption: <1 W Terminal Block Directions for use 1. Connect the out (Load) wire at first, following by the in (power wire); Please ensure a short circuit would not occur between connecting wire before you turn on the power; 2. Adjust rotary dial. It functions, as follows: 3. Rotate dial to the right for greater brightness. (At full right rotation the brightness is greatest.) 4. Rotate dial to the left for less brightness. (At full left rotation the light (load) will be off) Typical Applications POWER +- POWER SUPPLY + - OUTPUT -+ DC 12V 1-866-766-0509 | 1-905-474-0555 | RFQ@DLC-LUMISHEET.COM