MV Power Distribution Operation and Indication Components on iVB Panel GE Industrial Solutions iVB 12kV Intelligent Embeded Pole Vacuum Circuit Breaker iVB 12kV Intelligent Embeded Pole Vacuum Circuit Breaker is applied for Protection and Control MV Public Power Distribution and Industrial Grid Optional Accessories 1. Manual charge shaft • iTU Intelligent Relay Protection iVB 12kV Intelligent Embeded Pole Vacuum Circuit Breaker for Indoor Use Rated Voltage 12kV Rated Current 630-1250A Rated Short-Circuit Breaking Current 25kA, 31.5kA • Current Transformer 2. Manual close button • Under voltage shunt release 3. Open/Close indicator • Under voltage shunt release time delay 4. Charge indicator module • Network interlock module 6. Manual open button • Key interlock • Closing interlock electromagnetic 8. Machanical counter <The common specification for high voltage switchgear and control gear Standards> <High-voltage alternating current circuit breaker> • GB/T11022-1999 <Common specifications for high-voltage switchgear and control gear standards> • DL/T 402-2007 <High-voltage alternating current circuit breakers> • DL/T 403-2000 <12kV-40.5kV High-voltage alternating current circuit breakers> • DL/T 593-2006 <Common specifications for high-voltage switchgear and control gear standards> 8 4 9. Name plate • Primary moving contact Unit: mm • Interlock component Comprehensive Routine Testing Includes: • Power Frequency Withstand Voltage test from contact to contact, phase to phase and phase to earth • High and low voltage test for open and close circuit • Auxiliary and control circuit dielectric test • Circuit Resistance Test • Open and close speed test • Open and close time test • Contact bounce time • Relay protection multi-operation test • L-Frame 569 Technical Specification Rated voltage kV Rated frequency Hz Rated short time withstand current kA 25 31.5 Rated peak value withstand current kA 63 80 Rated short circuit making current kA 63 80 Operation sequence Action time Pole distance China Xihari Type Test • Dielectric test 205 12 Electircal life 266 430 150 O-0.3s-CO-180s-CO Opening time ≤ 50ms Total breaking time ≤ 65ms Closing time ≤ 60ms mm 8±1 Max. operation over voltage Mechanical life 50 time 548 538 10000 E2 • Temperature rise test 470 • Breaking capacity test • Dynamic and thermal stability test • Mechanical life test • Electrical life test • Mechanical life curve • EMC test 150 205 ≤ 2.5Un Greater China 865 Nanqiao Road, Fengxian District, For more information, please visit www.geindustrial.com 4F, Building 2, CTP, No.1 Hua Tuo Rd. Zhang Jiang Hi-Tech Park ShangHai 201400, China Shanghai, China 201203 T: +86 21 6710 1900 T : +86 21 3877 7888 Printing Code: IN201301B26EN F: +86 21 6710 1901 F : +86 21 3877 7600 © Copyright GE Industrial Solutions 2013 GE Breakers Co.,Ltd iVB Intelligent Embeded Pole Vacuum Circuit Breaker Intelligent and Compact Outline Dimension • Embeded arm <3.6-40.5kV Indoor High-voltage alternating current circuit breaker> <Electrical Relay> 3 • Secondary plug • JB/T 3855-2008 • GB/T 14598 - 2008 9 7 • Undercarrige • IEC 62271-100 • GB1984-2003 6 • Circuit breaker iVB 12kV Intelligent Embeded Pole Vacuum Circuit Breaker Product conforms to: • IEC 62271-1 1 2 7. Ready-to-close indicator Scope of supply <High-voltage alternating current circuit breaker> 5 5. Trip unit Shanghai Intelligence Modular Design Safety, Reliability Bring you reliable power solution Easy for integrated installation Originated from GE's strict quality control system and perfect design Easy for maintenance Highly Integration GE quality control system assurance With outstanding technology,iVB is almost iVB offers reliable solutions for grids With advanced manufactory process and integrated routing test, each free maintenance. When maintenance including newly-built , upgrade and breaker complies with the standards and specifications which ensured the is required, the integrated structure and refurbishment projects with its flexible best quality. interchangeablity makes the process safer function. VCB is the most critical component for MV Switchgear iVB integrates conveniently for you • Easy operation,easy maintenance and high reliability • Consummate and reliable interlock mechanic for personal safety • Recycle of components at 80% High performance current transformer • Rogowski Coil • Excellent linearity and no phase angle error • No risk of secondary open circuit • Easy to install and maintain • Integrated intelligent relay protection,control and precise sensor and easier. And when power fault occurs, iTU operation people can shorten the poweroff period in the absolutely safe area. iTU Intelligent relay protection • Friendly human machine interface • Multi communication protocol support • Smart grid solution Safety Easy for installation iTU Intelligent relay protection and control • LCD display and pull-down menu Transformer Rogowski Coil Protection system which combines with iVB,iTU and low power current iVB is easy to be transported and stored transformer secures the safety of all operations. with its slim size. It can apply for all kinds of demand and even more options with its Three iTU intelligent protection Aux. contact full parameters. Closing or charging status contact • Display all the parameter • iTU1(C3-ADV1)current protection • iTU2(C3-ADV6)current protection,curernt measurement&waveform capture,support Modbus RTU communication protocol • Supervise the status of VCB and shunt release • iTU3(C5-ADV8)current&voltage protection and • Fault recorder measurement,waveform capture,support Modbus RTU communication • Waveform capture and data record protocol • Touch-screen • Manual/auto reset switch • Measuring range plug L Frame • Relay protection input and output UV release • Modbus communication protocol • Option for HMI communication and IEC61850 available Comprehensive interlocks prevent incorrect operation • Standard mechanical and electrical interlock • Padlock for VCB open position Mechanical counter Panel key interlock device shunt release • Key lock for VCB open position • Open/close button lock • Key lock for VCB rack in/out • Network interlock • Rejection feature Charge motor Mechanical device Closing release Network interlock iVB