No improvisation on safety! Emergency lighting No improvisation on safety! Emergency lighting No! Contents No improvisation on safety! Introduction Quick selection guide 2 4 Emergency light fittings Presentation Range overview Rilux Primalum Luxa Domina Rapida Guardian 12 14 16 20 24 30 36 42 Emergency exit signs Presentation Range overview Astro Guida Quick Signal Maxi Slim 46 47 48 52 56 Conversion kits Presentation Range overview Everlux Ferro Everlux Power 60 61 62 64 Portable emergency lamps Presentation Range overview Top 4 Toplux Jodiolux 66 67 68 68 68 Remote control Teleur 73 Technical guide Contents Lighting and safety signs Design Maintenance Glossary 75 76 77 94 96 Index Numbered parts list ISC00648_01-2008_EN 97 1 Introduction Emergency lighting No! No improvisation on safety! Adapted to all building types, this emergency lighting range is one of the essential stand-by devices guaranteeing safety of occupants. It prevents panic movements in the event of serious problems (fire in particular). P93164 Many ranges to match all your needs perfectly Simplicity The light fittings guarantee safety of people in buildings open to the general public. Their simple design guarantees quick assembly and easy maintenance. By combining Teleur type remote controls with the fittings, the battery charge is preserved. Reliability With more than thirty years’ know-how in emergency lighting, Schneider Electric guarantees the reliability of its products in all circumstances. Thanks to the use of LEDs in stand-by periods, these fittings offer extremely low electricity consumption, thus contributing to building overall energy savings. Safety Automatically actuated in the event of power cuts, these fittings allow, these fittings offer: b clear marking of the emergency exits, b an efficient contribution to safe evacuation of people, b accessory lighting for a period of one to three hours. The fittings comply with European standards EN 60 598-1 & EN 60 598-2-22 and offer a high level of quality and safety meeting the various prevailing regulations. Design The self-contained emergency light fittings and their accessories are designed so as to blend perfectly into the aesthetics of various types of buildings, whether they be flush-mounted, in the false ceiling or surfacemounted. 2 ISC00648_01-2008_EN Emergency light fittings P93015 Rilux, Primalum, Luxa, Domina, Rapida, Guardian P93160 b Attractive design b Installation accessories for many types of ceiling, flush and wall mounts Emergency exit signs Astro Guida, Quick Signal, Maxi Slim P93023 b Long-life light b Modern appearance Conversion kits Everlux Ferro, Everlux Power Portable emergency lamps P93033 Top 4, Toplux, Jodiolux ISC00648_01-2008_EN b Convert ordinary fluorescent luminaire into self-contained emergency luminaires b Compatible with many tubes b Invisible: concealed into the fluorescent tube luminaire b High quality, high flux b Portable and rechargeable b Additional emergency function 3 Quick selection guide Emergency lighting No! No improvisation on safety! Emergency light fittings Rilux Accessories Standard version, IP 40, IK 06 / 07 see page 16 P92687 P92688 P92689 P92690 P93014 Protection rating Autonomy Average flux (lm) Emergency lighting (h) emergency condition / maintained mode P98698 Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) Protective grids Non maintained IP 40 IK 06 1 70 OVA37066E OVA50236E OVA50247E OVA50248E OVA50237E OVA50343E 90 OVA37067E OVA50238E OVA50249E OVA50250E OVA50239E OVA50344E 180 OVA37069E OVA50240E OVA50251E OVA50252E OVA50241E OVA50343E 250 OVA37070E OVA50240E OVA50251E OVA50252E OVA50241E OVA50343E 90 OVA37068E OVA50238E OVA50249E OVA50250E OVA50239E OVA50344E IP 40 IK 06 1 75 / 90 OVA37071E OVA50238E OVA50249E OVA50250E OVA50239E OVA50344E 3 75 / 90 OVA37072E OVA50238E OVA50249E OVA50250E OVA50239E OVA50344E IK 07 IK 06 3 Maintained Primalum Accessories Standard version, IP 42, IK 06 / 07 see page 20 P92687 P92688 Pictogram stickers (set of 10) Pictogram stickers (set of 10) P92689 P92690 P99857 Pictogram stickers (set of 10) EN Pictogram stickers (set of 10) ES Pictogram stickers (set of 10) Protective grids P102892 Protection rating Autonomy Average flux (lm) Emergency lighting (h) emergency condition / maintained mode P98698 Non maintained IP 42 IK 06 1 IK 07 65 OVA37037E OVA50284E OVA50285E OVA50286E OVA50287E OVA50288E OVA50343E 75 OVA37038E OVA50289E OVA50290E OVA50291E OVA50292E OVA50293E OVA50344E 110 OVA37073E OVA50284E OVA50285E OVA50286E OVA50287E OVA50288E OVA50343E 160 OVA37039E OVA50284E OVA50285E OVA50286E OVA50287E OVA50288E OVA50343E 230 OVA37040E OVA50289E OVA50290E OVA50291E OVA50292E OVA50293E OVA50344E Luxa Accessories Standard version, IP 42 / IP 65, IK 06 / 07 / 08 see page 24 P92687 P92688 P92689 P92690 P99857 P93015 Protection Autonomy rating (h) P98698 P93016 Average flux (lm) Emergency lighting emergency condition / maintained mode Pictogram stickers (set of 10) 60 OVA37191E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E 100 OVA37093E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E IK 07 180 OVA37192E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E IK 06 210 OVA37100E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 370 OVA37095E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 60 OVA37193E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E 90 OVA37094E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 115 OVA37194E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E 60 OVA37195E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E 100 OVA37098E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E IK 08 180 OVA37196E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E IK 07 210 OVA37101E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 370 OVA37102E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E IK 07 3 60 OVA37197E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E IK 08 115 OVA37198E OVA50242E OVA50253E OVA50254E OVA50243E OVA50279E OVA50343E OVA50345E 100 / 185 OVA37096E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 90 / 165 OVA37097E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E 100 / 185 OVA37099E OVA50244E OVA50255E OVA50256E OVA50245E OVA50280E OVA50344E OVA50346E Pictogram stickers (set of 10) Pictogram stickers (set of 10) EN Pictogram stickers (set of 10) ES Pictogram stickers (set of 10) Protective grids Flush mounting box Non maintained IP 42 IK 06 1 IK 06 3 IK 07 IP 65 IK 07 1 Maintained IP 42 IK 06 1 3 IP 65 IK 07 1 4 ISC00648_01-2008_EN Spare parts P98733 P98733 Fluorescent tubes Batteries (Ni-Cd) OVA51005E OVA51012E OVA51006E OVA51012E OVA51009E OVA51016E OVA51011E OVA51021E OVA51006E OVA51019E OVA51007E OVA51018E OVA51007E OVA51019E Spare parts P102895 P98693 P98694 P98733 P98733 White frames Grey frames Flush mounting box False ceiling kit Hanging / electrified track kit Fluorescent tubes Batteries (Ni-Cd) OVA53028E OVA53029E OVA53033E OVA53023E OVA50347E OVA51005E OVA51012E OVA53030E OVA53031E OVA53034E OVA53023E OVA50347E OVA51006E OVA51012E OVA53028E OVA53029E OVA53033E OVA53023E OVA50347E OVA51009E OVA51016E OVA53028E OVA53029E OVA53033E OVA53023E OVA50347E OVA51009E OVA51016E OVA53030E OVA53031E OVA53034E OVA53023E OVA50347E OVA51011E OVA51021E P102893 P102894 Spare parts P98733 P98697 White frames P98695 P98696 Black frames Grey frames P98693 Aluminium frames P98694 False ceiling Hanging / kit electrified track kit P101280 P101281 Exit sign kit Exit sign kit Exit sign kit ceiling mounting flag mounting wall mounting - - OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - P98733 P101282 Fluorescent Batteries tubes (Ni-Cd) Pictogram sticker set for exit sign kits OVA51005E OVA51012E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51006E OVA51013E OVA50283E OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51010E OVA51016E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51043E OVA51019E OVA50283E OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51008E OVA51022E OVA50283E OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51037E OVA51019E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51006E OVA51017E OVA50283E OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51044E OVA51038E - OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51005E OVA51012E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51006E OVA51013E OVA50283E OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51010E OVA51016E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51043E OVA51019E OVA50283E OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51008E OVA51022E OVA50283E OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51037E OVA51019E - OVA50349E OVA50351E OVA50350E OVA53036E OVA50348E OVA50347E - - - OVA51044E OVA51038E - OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51007E OVA51013E OVA50283E OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51007E OVA51021E OVA50283E OVA50352E OVA50354E OVA50353E OVA53037E OVA50348E OVA50347E OVA50328E OVA50329E OVA50330E OVA51007E OVA51013E OVA50283E ISC00648_01-2008_EN 5 Quick selection guide (cont.) Emergency lighting No! No improvisation on safety! Emergency light fittings Domina Accessories Self-diagnosis version (Activa) IP 42 / IP 65, IK 08 see page 30 P92687 P92688 P92689 P92690 Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) EN Pictogram stickers (set of 10) ES Pictogram stickers (set of 10) P99857 P99858 Protection Autonomy Average flux (lm) Emergency lighting rating (h) emergency condition / maintained mode Non maintained IP 42 IK 08 1 100 OVA37226E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 140 OVA37212E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 150 OVA37213E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 210 OVA37216E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 400 OVA37224E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 640 OVA37217E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 85 OVA37215E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 100 OVA37227E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 140 OVA37218E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 150 OVA37219E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 210 OVA37222E OVA50267E OVA50268E OVA50269E OVA50270E OVA50271E 400 OVA37225E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 640 OVA37223E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E 85 OVA37221E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E IP 42 IK 08 1 145 / 240 OVA37214E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E IP 65 IK 08 1 145 / 240 OVA37220E OVA50272E OVA50273E OVA50274E OVA50275E OVA50276E P92689 P92690 P99857 3 IP 65 IK 08 1 3 Maintained Rapida Accessories Standard version, IP 42, IK 04 / 05 see page 36 P92687 P92688 P99859 Protection Autonomy rating (h) Average flux (lm) Emergency lighting emergency condition / maintained mode Pictogram stickers (set of 10) Pictogram stickers (set of 10) Pictogram stickers (set of 10) EN Pictogram stickers (set of 10) ES Pictogram stickers (set of 10) 50 OVA37576E OVA50257E OVA50258E OVA50259E OVA50260E OVA50261E 90 OVA37577E OVA50262E OVA50263E OVA50264E OVA50265E OVA50266E 100 / 190 OVA37578E OVA50262E OVA50263E OVA50264E OVA50265E OVA50266E Non maintained IP 42 IK 04 1 IK 05 Maintained IP 42 IK 05 1 Guardian Accessory Spare parts Standard version, IP 65, IK 07 see page 42 P101289 P93018 P98729 P101288 Protection Autonomy rating (h) Average flux (lm) Emergency lighting Protective grids Halogen bulbs Batteries Pb IP 65 IK 07 1 230 OVA41437E OVA50342E OVA51002E OVA51025E 400 OVA41435E OVA50342E OVA51003E OVA51024E 1050 OVA41436E OVA50342E OVA51004E OVA51024E 6 ISC00648_01-2008_EN Spare parts P98698 Protective grids P93016 Flush mounting box P98693 False ceiling kit P101281 P101280 P98694 P101282 Hanging / electrified track kit Exit sign kit Exit sign kit Exit sign kit ceiling mounting flag mounting wall mounting P98733 P98733 Fluorescent tubes Batteries (Ni-Cd) Pictogram sticker set for exit sign kits - OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51037E OVA51016E OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51037E OVA51016E - OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51041E OVA51016E OVA50277E OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51009E OVA51019E - OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51042E OVA51039E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51042E OVA51039E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51041E OVA51040E OVA50277E OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51037E OVA51016E - OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51037E OVA51016E - OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51041E OVA51016E OVA50277E OVA53019E OVA53021E OVA53023E OVA50347E - - - OVA51009E OVA51019E - OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51042E OVA51039E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51042E OVA51039E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51041E OVA51040E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51007E OVA51016E OVA50277E OVA53020E OVA53022E OVA53023E OVA50347E OVA53024E OVA53025E OVA53026E OVA51007E OVA51016E OVA50277E Spare parts P98698 P102832 P98698 P102833 P102898 P98733 P98733 P102897 Protective grids for flush mounting Protective grids for wall mounting Flush Exit sign kit Exit sign kit Exit sign kit Flag type Fluorescent mounting and (visibility 30 m) (visibility 30 m) (visibility 23 m) bracket for exit tubes faste ceiling kit Left and right Down Left + right + sign kits down OVA53012E OVA50343E OVA53014E - - - - OVA51037E OVA51012E - OVA53013E OVA50344E OVA53015E OVA53016E OVA53017E OVA53018E OVA53027E OVA51043E OVA51013E OVA50278E OVA53013E OVA50344E OVA53015E OVA53016E OVA53017E OVA53018E OVA53027E OVA51007E OVA51013E OVA50278E Batteries (Ni-Cd) Pictogram sticker set for exit signs kit OVA53018E - ISC00648_01-2008_EN 7 Quick selection guide (cont.) Emergency lighting No! No improvisation on safety! Emergency exit signs Astro Guida Accessories Self-diagnosis version (Activa) Standard version + see page 48 P92690 + P99857 P98730 + + P98731 P93012 Visibility (m) Autonomy (h) Emergency exit signs Ceiling, hanging and electrified track kit Protective grid EN Exit sign screens for 1 or 2 sides ES Exit sign screens for 1 or 2 sides OVA38466E OVA50356E OVA50357E OVA50281E OVA50282E 1 OVA38464E OVA50356E OVA50357E OVA50281E OVA50282E 3 OVA38465E OVA50356E OVA50357E OVA50281E OVA50282E Self-diagnosis version (Activa), IP 42, IK 06 24 1 Standard version, IP 42, IK 06 24 Quick Signal Exit sign screens Self-diagnosis version (Activa) Standard version + see page 52 P92687 P92688 + + P92689 + + + P92690 + P101292 Visibility (m) Autonomy (h) Emergency exit signs (screen not included) Exit sign screens for 1 side signalling Exit sign screens for 2 sides signalling EN Exit sign screens for 1 or 2 sides Self-diagnosis version (Activa), IP 40, IK 07 28 1 OVA38506E OVA50319E OVA50320E OVA50321E OVA50322E OVA50323E OVA50324E 1 OVA38504E OVA50319E OVA50320E OVA50321E OVA50322E OVA50323E OVA50324E 3 OVA38505E OVA50319E OVA50320E OVA50321E OVA50322E OVA50323E OVA50324E Standard version, IP 40, IK 07 28 Maxi Slim Exit sign screens Standard version, IP 40 see page 56 + P92687 + P92688 + P92689 + + P101277 Visibility (m) Autonomy (h) Emergency exit signs Exit sign screens for 1 side signaling 60 1 OVA38072E OVA53000E OVA53001E OVA53002E OVA53003E OVA53004E 3 OVA38073E OVA53000E OVA53001E OVA53002E OVA53003E OVA53004E 1 OVA38074E OVA53005E OVA53006E OVA53007E OVA53008E OVA53009E 3 OVA38075E OVA53005E OVA53006E OVA53007E OVA53008E OVA53009E 80 8 Exit sign screens for 2 sides signalling ISC00648_01-2008_EN Spare parts P92995 Flag bracket (spare part) Pictogram sticker set (spare part) OVA50355E OVA50246E OVA50355E OVA50246E OVA50355E OVA50246E Accessories + Spare parts P99857 P98732 P101295 + P101302 P101293 ES Exit sign screens for 1 or 2 sides False ceiling mounting kit Hanging kit Wall / flag type bracket Batteries Ni-Cd OVA53032E OVA50318E OVA50314E OVA50316E OVA51014E OVA53032E OVA50318E OVA50314E OVA50316E OVA51014E OVA53032E OVA50318E OVA50314E OVA50316E OVA51015E Accessories Spare parts P101297 P98692 P101296 Protective grids Fluorescent tube Batteries Ni-Cd OVA53010E OVA51034E OVA51019E OVA53010E OVA51034E OVA51019E OVA53011E OVA51035E OVA51039E OVA53011E OVA51035E OVA51039E ISC00648_01-2008_EN 9 Quick selection guide (cont.) Emergency lighting No! No improvisation on safety! Conversion kits Everlux Ferro Spare parts Standard version see page 62 P93022 P101300 P101301 Batteries Conversion kits Batteries Ni-Cd LED side by side OVA43101E OVA51027E OVA51033E in line OVA43102E OVA51026E OVA51033E side by side OVA43103E OVA51029E OVA51033E in line OVA43104E OVA51028E OVA51033E 3.6 V - 2 Ah in line OVA43105E OVA51026E OVA51033E 3.6 V - 4 Ah in line OVA43106E OVA51028E OVA51033E 3.6 V - 2 Ah 3.6 V - 4 Ah Everlux Power Spare parts Standard version see page 64 P101300 P101294 P93023 Conversion kits Batteries Ni-Cd LED 3.6 V - 4.5 Ah Batteries in line OVA43107E OVA51030E OVA51033E 4.8 V - 4.5 Ah in line OVA43108E OVA51031E OVA51033E 6.0 V - 4.5 Ah in line OVA43109E OVA51032E OVA51033E Remote control Teleur see page 73 P93007 Maximum number of luminaires 10 Width in modules of 18 mm Remote control 100 4.4 OVA50325E 500 4 OVA50326E ISC00648_01-2008_EN Portable emergency lamps Top 4 Accessories Spare parts IP 40 see page 68 P101305 P101307 P93163 P93036 P93159 P101304 P93029 Lamp and autonomy main 6W-4h Portable emergency lamp Lamp supports Diffuser signaller Charger Battery Pb Main lamp Auxiliary lamp auxiliary 1.5 W - 15 h OVA41317E OVA50360E OVA50315E OVA50358E OVA51023E OVA51001E OVA51000E Toplux Accessories Spare parts IP 55 see page 68 P101289 P93163 P93036 P101305 P93159 P101304 P93031 Lamp and autonomy Portable emergency lamp Lamp supports Diffuser signaller Charger Batteries Pb Main lamp Auxiliary lamp main auxiliary 10 W - 1 h 30 1.5 W - 15 h OVA41318E OVA50360E OVA50315E OVA50358E OVA51023E (1) OVA51002E OVA51000E 10 W - 4 h 1.5 W - 24 h OVA41319E OVA50360E OVA50315E OVA50358E OVA51036E (2) OVA51002E OVA51000E (1) Lead battery (2) Ni-Cd battery Jodiolux Accessories Spare parts IP 65, IK 07 see page 68 P101303 P101289 P101305 P93159 P101306 P93033 Charger Battery Ni-Cd Main lamp Auxiliary lamp auxiliary Portable emergency lamp Lamp supports main Lamp and autonomy 10 W - 4 h 1.5 W - 24 h OVA41033E OVA50359E OVA50358E OVA51020E OVA51002E OVA51000E ISC00648_01-2008_EN 11 Presentation Emergency light fittings P101575 Avoid public panic for greater safety P101574 No improvisation on safety! P61607 No! b These devices come on in the event of a mains failure to provide a sufficient lighting level. b As a result: v all panic is avoided; v the path and obstacles are made visible for movements in complete safety. b Enhanced with “running man” type stickers, they are transformed into emergency exit signs. b These lighting units can be deactivated, by means of a Teleur remote control, during periods of building inactivity so as to: v ensure their satisfactory operation when the premises are open to the public, and v extend the service life of their batteries. School, administration building, etc. Well designed products Outdoors, factory, very high warehouse, etc. Hotel, office, museum, etc. Special holes for fast, simplified mounting and dismounting. P98734 P98735 P101278 Ease of installation Quick connection by plug-in terminal board. Heads that can swivel in all directions. P101285 P101284 P101283 Discretion, looks, sealing Choice of three colours to adapt to the environment. Simple and discreet. Reinforced sealing. Self-diagnosis version (Activa) 12 P101287 P101286 Adaptable exit sign Some light fittings exist in a self-test version. Domina have such a version. They can make their operational diagnosis and tell whether the light source, the battery or the device is defective. The result of the diagnosis is displayed by a diode that flashes at an appropriate rate and in an appropriate colour. This makes it possible to save time, particularly during the test and maintenance stages. ISC00648_01-2008_EN ISC00648_01-2008_EN 13 Emergency light fittings No improvisation on safety! P102892 Technical specifications Protection rating IP 40 Self-diagnosis Autonomy 1h b IK 06 / 07 3h b IK 06 Adptable exit sign Average flux in non-maintained mode 60 lm 65 lm 70 lm b IK 06 75 lm 90 lm b IK 06 100 lm 110 lm 115 lm 160 lm 180 lm b IK 07 210 lm 230 lm 250 lm b IK 07 370 lm Average flux in maintained mode (emergency condition) 75 lm b IK 06 90 lm 100 lm Installation methods Wall b Flush Ceiling b False ceiling 45° mounting Hanging Electrified track IP 42 or IP 65 b IK 06 / 07 b IK 06 / 07 b IK 06 / 07 / 08 b b IK 06 / 07 b IK 06 b IK 06 b IK 06 / 07 b IK 07 b IK 07 / 08 b IK 07 b IK 07 / 08 b IK 06 / 07 b IK 07 b IK 07 b IK 07 b IK 06 b b b b b b b b 6/11W: 122 x 270 x (55) 6/11 W: 125 x 288 x (58) P102836 b b b b 8W: 100 x 331 x (46) P102837 P99867 Dimensions (mm) - h x w x (d) 6 W: 100 x 255 x (46) P99864 IP 42 b IK 06 The drawings are scale drawings P99865 Luxa P93015 Primalum P93014 Rilux 8/18 W: 142 x 370 x (60) 8 W: 135 x 348 x (58) P99868 No! Range overview P99866 11/18 W: 125 x 280 x (55) Page 14 16 20 24 ISC00648_01-2008_EN Guardian P99858 Technical specifications Protection rating IP 42 or IP 65 Self-diagnosis b Autonomy 1h b IK 08 3h b IK 08 Adptable exit sign b Average flux in non-maintained mode 50 lm 85 lm b IK 08 90 lm 100 lm b IK 08 140 lm b IK 08 150 lm b IK 08 200 lm 210 lm b IK 08 400 lm b IK 08 640 lm b IK 08 1050 lm IP 42 IP 65 b IK 04 / 05 b IK 07 b b IK 04 b IK 05 b IK 07 b IK 07 b IK 07 b IK 07 Average flux in maintained mode (emergency condition) 100 lm 145 lm b IK 08 Installation methods Wall Flush Ceiling False ceiling 45° mounting Hanging Electrified track P93018 Rapida P99859 Domina b IK 05 b b b b b b b b b Horizontally or vertically 6 W: 120 x 284 x (52) 2 x 10 W / 2 x 20 W: 287 x 434 x (168) Dimensions (mm) - h x w x (d) 6/11 W: 149 x 302 x (68) P99871 8/24 W: 169 x 382 x (82) P99872 P99870 P99869 The drawings are scale drawings P99873 b b 8 W: 120 x 360 x (52) 2 x 50 W: 280 x 440 x (230) Page ISC00648_01-2008_EN 30 36 42 15 Rilux Emergency light fittings Standard version IP 40, IK 06 / 07 No! Good performance and attractive design at the right price. P103011 No improvisation on safety! P93014 Up to 250 lumens. P103015 3. Access from five sides With easy-to-drill and pre-stamped holes and 16 mm Ø tube inlet. 16 ISC00648_01-2008_EN P101283 1. Discrete and aesthetic design Small and nicely shaped. P103012 P101278 2. Fast installation Handy: special holes for fitting and removing while leaving the screw in place. P103014 P103013 The connector is fitted right from the start. The connector passes through the quick mounting plate and easily clips into place. Click!! Click!! Mechanical and electrical links are made when the unit clips into place at the last moment. P101286 4. Easy to transform The light fitting can be transformed into an Exit sign with a set of stickers. ISC00648_01-2008_EN 17 Rilux (cont.) Emergency light fittings Standard version IP 40, IK 06 / 07 No! No improvisation on safety! P93014 Technical specifications b b b b b b b b b b b e Available for maintained or non-maintained operation Installation: quick mounting on wall or ceiling Compliant with IEC EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 40, IK 06 / 07 Insulation class: II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Light source: fluorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 24 h P92716 P92718 Dimensions Dimensions (mm) 6W Quick mounting 70 lm A B C 100 255 46 8W 75 and 90 lm 100 331 46 11/18 W 180 and 250 lm 125 280 55 Installation rules (examples with 70 and 250 lm) The photometric data is approximated (average values): for project calculations, scattering coefficients must be taken into consideration. P94340 Rilux 70 lm Installation methods 3m P92717 Wall (installation without accessories) 6.70 m 1 1 1 1 6.70 m 6.70 m P94341 Rilux 250 lm Ceiling (installation without accessories) 3m 9.90 m 1 1 9.90 m 18 1 1 9.90 m ISC00648_01-2008_EN Product catalogue numbers Rilux Protection rating Autonomy Average flux (lm) Lamp (h) emergency maintained rated socket condition mode power (W) Consumption Ni-Cd battery (VA) Weight Cat. no. (kg) Non-maintained P93014 IP 40 IK 06 1 IK 07 IK 06 3 70 - 6 G5 2.5 2.4 V 1.5 Ah 0.55 OVA37066E 90 - 8 G5 2.5 2.4 V 1.5 Ah 0.63 OVA37067E 180 - 11 2G7 2.9 4.8 V 1.5 Ah 0.75 OVA37069E 250 - 18 2G11 3.0 7.2 V 1.5 Ah 0.85 OVA37070E 90 - 8 G5 2.7 6.0 V 1.5 Ah 0.80 OVA37068E Maintained IP 40 IK 06 1 75 90 8 G5 10.1 6.0 V 0.6 Ah 0.65 OVA37071E 3 75 90 8 G5 10.8 6.0 V 1.5 Ah 0.80 OVA37072E Protective grids Teleur remote control Teleur 500 remote control P92688 P92689 P92690 Pictogram stickers (set of 10) P98698 Pictogram stickers (set of 10) P93007 Pictogram stickers (set of 10) P93008 Pictogram stickers (set of 10) P92687 Accessory catalogue numbers Compatibility Dimensions (mm) Cat. no. height x width x depth Rilux 6 W 88 x 240 OVA50236E Rilux 8 W 88 x 316 OVA50238E Rilux 11 / 18 W 120 x 264 OVA50240E Rilux 6 W 88 x 240 OVA50247E Rilux 8 W 88 x 316 OVA50249E Rilux 11 / 18 W 120 x 264 OVA50251E Rilux 6 W 88 x 240 OVA50248E Rilux 8 W 88 x 316 OVA50250E Rilux 11 / 18 W 120 x 264 OVA50252E Rilux 6 W 88 x 240 OVA50237E Rilux 8 W 88 x 316 OVA50239E Rilux 11 / 18 W 120 x 264 OVA50241E Rilux 6 /11/18 W 170 x 333 x 89 OVA50343E Rilux 8 W 180 x 393 x 89 OVA50344E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E Spare parts catalogue numbers P98733 Fluorescent tubes P98733 Batteries (Ni-Cd) ISC00648_01-2008_EN Description Compatibility 6 W, G5 OVA37066E Cat. no. OVA51005E 8 W, G5 OVA37067E, OVA37068E OVA51006E OVA37071E, OVA37072E OVA51007E 11 W, 2G7 OVA37069E OVA51009E 18 W, 2G11 OVA37070E OVA51011E 2.4 V, 1.5 Ah OVA37066E, OVA37067E OVA51012E 6 V, 1.5 Ah OVA37068E, OVA37072E OVA51019E 6 V, 0.6 Ah OVA37071E OVA51018E 4.8 V, 1.5 Ah OVA37069E OVA51016E 7.2 V, 1.5 Ah OVA37070E OVA51021E 19 Emergency light fittings Primalum Standard version IP 42, IK 06 / 07 No! No improvisation on safety! Easy to install, easy to maintain. P106290 2 Primalum is designed in 2 parts for the ultimate in easy installation: 1 - 1 Light fitting with all of the active elements, the reflector and the diffuser. P106296 - 2 Box with the connector. With easy to drill pre-stamped holes and 16 Ø tube inlet. 20 P106289 6. Maximum organization P106286 P106287 5. Access from 5 sides Cable organizer to hold the cables. ISC00648_01-2008_EN P106294 P106295 P106289 1. Fast installation Click!! Click!! Can be pre-installed so that the light fitting then just clicks in place. P106288 Click!! P106285 P106284 2. Safe and easy maintenance Easy access to the parts thanks to the fastened diffuser. Easy, safe battery connection, no risk. P98698 P98693 P98694 P106293 3. Versatile: an accessory for every type of installation For installation in false ceilings, flush-mounted, surface-mounted, in electrical conduits, etc. P106292 P106291 4. Personalized Straight frames in 2 colours: white and grey. P106282 8. Secure fastening P106283 P106287 7. Easy to fasten and align Click!! Several easy ways of fastening the light fitting. ISC00648_01-2008_EN There is no chance of getting it wrong when joining the two parts of the light fitting. 21 Primalum (cont.) Emergency light fittings Standard version IP 42, IK 06 / 07 No! No improvisation on safety! P102892 Technical specifications b b b b b b b b b b b e Available for non-maintained operation Installation: quick mounting on wall or ceiling Compliant with IEC EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42, IK 06 / 07 Insulation class: II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Light source: fluorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 24 h P102835 P102896 Dimensions Coloured frames (white, grey) Installation methods P102838 Wall (installation without accessories) Dimensions (mm) A B C 6/11 W 65, 100 and 160 lm 122 270 55 8/18 W 75 and 230 lm 142 370 60 Installation rules (examples with 65 and 230 lm) The photometric data is approximated (average values): for project calculations, scattering coefficients must be taken into consideration. Flush (installation with flush mounting box) P94340 Primalum 65 lm 3m Ceiling (installation without accessories) 6.70 m 1 1 6.70 m Primalum 230 lm P94341 False ceiling (installation with false ceiling kit + flush mounting box) 1 1 6.70 m 3m Hanging (installation with hanging / electrified track kit) 9.90 m 1 1 9.90 m 1 1 9.90 m Electrified track (installation with hanging / electrified track kit) 22 ISC00648_01-2008_EN Product catalogue numbers Primalum Protection rating Autonomy Average flux (lm) Lamp Consumption Ni-Cd battery Weight Cat. no. (h) (kg) emergency maintained rated socket (VA) condition mode power (W) Non-maintained 1 IK 07 65 - 6 G5 2.5 2.4 V 1.5 Ah 0.55 OVA37037E 75 - 8 G5 2.5 2.4 V 1.5 Ah 0.63 OVA37038E 110 - 11 2G7 2.9 4.8 V 1.5 Ah 0.75 OVA37073E 160 - 11 2G7 2.9 4.8 V 1.5 Ah 0.75 OVA37039E 230 - 18 2G11 3.0 7.2 V 1.5 Ah 0.85 OVA37040E Accessory catalogue numbers OVA37038E OVA51006E Pictogram stickers (set of 10) Pictogram stickers (set of 10) 18 W, 2G11 OVA37040E 2.4 V, 1.5 Ah OVA37037E, OVA51012E OVA37038E OVA51011E 4.8 V, 1.5 Ah OVA37039E, OVA51016E OVA37073E 7.2 V, 1.5 Ah OVA37040E Pictogram stickers (set of 10) Pictogram stickers (set of 10) OVA50289E Primalum 6/11 W 108 x 255 OVA50285E Primalum 8/18 W 131 x 355 OVA50290E Primalum 6/11 W 108 x 255 OVA50286E Primalum 8/18 W 131 x 355 OVA50291E Primalum 6/11 W 108 x 255 EN language OVA50287E Primalum 6/11 W 108 x 255 ES language OVA50288E OVA51021E Primalum 8/18 W 131 x 355 EN language OVA50292E Primalum 8/18 W 131 x 355 ES language OVA50293E Flush mounting box Primalum 6/11 W 138 x 312 x 56 OVA53033E Primalum 8/18 W 158 x 407 x 56 OVA53034E False ceiling kit (also order a flush mounting box) All models OVA53023E Hanging / electrified track kit All models OVA50347E Primalum 6/11 W White 155 x 328 x 8 OVA53028E Primalum 8/18 W White 175 x 425 x 8 OVA53030E Primalum 6/11 W Grey 155 x 328 x 8 OVA53029E P102894 Frames Primalum 8/18 W Grey 175 x 425 x 8 OVA53031E Primalum 6/11 W 170 x 333 x 89 OVA50343E Primalum 8/18 W 180 x 393 x 89 OVA50344E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E P98698 Protective grids Teleur remote control P93007 P98733 Batteries (Ni-Cd) OVA37039E, OVA51009E OVA37073E OVA50284E Primalum 8/18 W 131 x 355 P99857 11 W, 2G7 Dimensions (mm) Cat. no. height x width x depth Primalum 6/11 W 108 x 255 P92687 8 W, G5 Compatibility P92688 OVA51005E P92689 OVA37037E P92690 6 W, G5 P102895 Compatibility Cat. no. P98733 Fluorescent tubes Description P98693 Spare parts catalogue numbers P98694 P102892 IP 42 IK 06 ISC00648_01-2008_EN 23 Luxa Emergency light fittings Standard version IP 42 / IP 65, IK 06 / 07 / 08 No! No improvisation on safety! P106275 Wide range. Luxa has many options so it is suitable for any type of installation: Sealed version IP 65 and unsealed version IP42. Permanent or Not Permanent. Battery operation for 1 or 3 hours. P106280 From 60 to 370 lumens. P106272 5. Quality materials Polycarbonate (PC) used in all of the plastic parts. A sturdy product. 24 7. Easy access P106270 P106271 6. Easy to fasten Various options for fastening the light fitting. Quality pre-stamped holes that are easy to drill through. 16 or 20 Ø tube inlet, to IP standards. ISC00648_01-2008_EN P93015 P106277 P106278 1. Easy installation Separate connector for fast, easy connection. Click!! P106247 Click!! P106274 P106273 2. Safe and easy maintenance Easy access to the parts as the fluorescent tube and the battery are incorporated in one piece. P101280 P98693 P98694 3. Versatile: an accessory for every type of installation Accessories for installing the light fitting in false ceilings, in electrical conduits, flush-mounted, surface-mounted, etc. Converts to an emergency illuminated sign. P92991 P106279 P106276 4. Personalized Curved frames available in 4 colours: black, white, grey and aluminium. P106269 8. Sealed version For places that need installation that is protected from moisture (car park for example). ISC00648_01-2008_EN 25 Luxa (cont.) Emergency light fittings Standard version IP 42 / IP 65, IK 06 / 07 / 08 No! No improvisation on safety! Technical specifications P93015 b b b b b b b b b b b b P92991-P106279 e Available for maintained or non-maintained operation Installation for flush mounting and false ceiling Personalized with coloured frames Compliant with IEC EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42 or IP 65, IK 06 / 07 / 08 Insulation class: II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Light source: fluorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h for models with 1 h autonomy P92692 Dimensions Coloured frames (black, white, grey, aluminium) Dimensions (mm) Installation methods P92702 Wall (installation without accessories) A B C 6/11 W 60, 115 and 180 lm 125 288 58 8W 90, 100, 210 and 370 lm 135 348 58 Installation rules (examples for 60 and 370 lm) The photometric data is approximated (average values): for project calculations, scattering coefficients must be taken into consideration. Luxa 60 lm P92700 Flush (installation with flush mounting box) 3m 6.90 m Ceiling (installation without accessories) 1 1 1 1 6.90 m 6.90 m False ceiling (installation with false ceiling kit + flush mounting box) P94342 Luxa 370 lm 3m 11.20 m Hanging (installation with hanging / electrified track kit) 1 1 11.20 m 1 1 11.20 m Electrified track (installation with hanging / electrified track kit) 26 ISC00648_01-2008_EN Product catalogue numbers Luxa Protection rating Autonomy Average flux (lm) Lamp Consumption Ni-Cd battery (h) emergency maintained rated socket (VA) condition mode power (W) Weight Cat. no. (kg) Non-maintained P93015 IP 42 IK 06 60 - 6 G5 5 2.4 V 1.5 Ah 0.85 OVA37191E 100 - 8 G5 5 3.6 V 1.5 Ah 0.90 OVA37093E IK 07 180 - 11 2G7 5 4.8 V 1.5 Ah 0.98 OVA37192E IK 06 210 - 8 G5 5 6.0 V 1.5 Ah 0.97 OVA37100E 370 - 8 G5 6.5 8.4 V 1.5 Ah 1.10 OVA37095E 60 - 6 G5 5 6.0 V 1.5 Ah 1.05 OVA37193E 90 - 8 G5 5 4.8 V 2.2 Ah 0.97 OVA37094E 115 - 11 2G7 5 6.0 V 2.2 Ah 1.05 OVA37194E 60 - 6 G5 5 2.4 V 1.5 Ah 0.87 OVA37195E 100 - 8 G5 5 3.6 V 1.5 Ah 0.92 OVA37098E IK 08 180 - 11 2G7 5 4.8 V 1.5 Ah 1.00 OVA37196E IK 07 210 - 8 G5 5 6.0 V 1.5 Ah 0.99 OVA37101E 370 - 8 G5 6.5 8.4 V 1.5 Ah 1.12 OVA37102E 60 - 6 G5 5 6.0 V 1.5 Ah 1.07 OVA37197E 115 - 11 2G7 5 6.0 V 2.2 Ah 1.07 OVA37198E IK 06 1 3 IK 07 IP 65 IK 07 IK 07 1 3 IK 08 Maintained IP 42 IP 65 ISC00648_01-2008_EN IK 06 IK 07 1 100 185 8 G5 10.5 3.6 V 1.5 Ah 0.90 OVA37096E 3 90 165 8 G5 10 7.2 V 1.5 Ah 1.10 OVA37097E 1 100 185 8 G5 10.5 3.6 V 1.5 Ah 0.92 OVA37099E 27 Emergency light fittings Luxa (cont.) Standard version IP 42 / IP 65, IK 06 / 07 / 08 No! No improvisation on safety! Pictogram stickers (set of 10) P92688 P99857 Pictogram stickers (set of 10) P92689 Pictogram stickers (set of 10) P92690 Pictogram stickers (set of 10) P92687 Accessory catalogue numbers Dimensions (mm) Cat. no. height x width x depth Luxa 6/11 W 116 x 284 OVA50242E Luxa 8 W 126 x 342 OVA50244E Luxa 6/11 W 116 x 284 OVA50253E Luxa 8 W 126 x 342 OVA50255E Luxa 6/11 W 116 x 284 OVA50254E Luxa 8 W 126 x 342 OVA50256E Luxa 6/11 W EN language 116 x 284 OVA50243E Luxa 6/11 W ES language 116 x 284 OVA50279E Luxa 8 W EN language 126 x 342 OVA50245E Luxa 8 W ES language 126 x 342 OVA50280E Luxa 6/11 W 114 x 272 x 56 OVA50345E Luxa 8 W 124 x 332 x 56 OVA50346E P93016 Flush mounting box Compatibility Frames Protective grids 28 OVA50348E All models OVA50347E Luxa 6/11 W White 141 x 307 x 26 OVA50349E Luxa 8 W White 154 x 367 x 26 OVA50352E Luxa 6/11 W Black 141 x 307 x 26 OVA50351E Luxa 8 W Black 154 x 367 x 26 OVA50354E Luxa 6/11 W Grey 141 x 307 x 26 OVA50350E Luxa 8 W Grey 154 x 367 x 26 OVA50353E Luxa 6/11 W Aluminium 141 x 307 x 26 OVA53036E Luxa 8 W Aluminium 154 x 367 x 26 OVA53037E Luxa 6/11 W 170 x 333 x 89 OVA50343E Luxa 8 W 180 x 393 x 89 OVA50344E Ceiling mounting OVA50328E P101280 Luxa 8 W Pictograms provided 144 x 270 Flag mounting OVA50329E Wall mounting OVA50330E P93007 Exit sign kits Teleur remote control All models P98693 P98694 P98695 Hanging / electrified track kit P98698 False ceiling kit (also order a flush mounting box) All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E ISC00648_01-2008_EN Spare parts catalogue numbers Fluorescent tubes Description Compatibility Cat. no. 6 W, G5 OVA37191E, OVA37195E OVA51005E OVA37193E, OVA37197E OVA51037E OVA37093E, OVA37094E, OVA37098E OVA51006E OVA37100E, OVA37101E OVA51043E OVA37096E, OVA37097E, OVA37099E OVA51007E OVA37095E, OVA37102E OVA51008E OVA37192E, OVA37196E OVA51010E OVA37194E, OVA37198E OVA51044E 2.4 V, 1.5 Ah OVA37191E, OVA37195E OVA51012E 3.6 V, 1.5 Ah OVA37093E, OVA37096E, OVA37098E, OVA37099E OVA51013E 4.8 V, 1.5 Ah OVA37192E, OVA37196E OVA51016E 4.8 V, 2.2 Ah OVA37094E OVA51017E 6.0 V, 1.5 Ah OVA37100E, OVA37101E, OVA37193E, OVA37197E, OVA51019E 6.0 V, 2.2 Ah OVA37194E, OVA37198E OVA51038E 7.2 V, 1.5 Ah OVA37097E OVA51021E 8.4 V, 1.5 Ah OVA37095E, OVA37102E P98733 8 W, G5 Pictogram sticker set (4 pictograms for exit signs kit) P92687 P98733 Batteries (Ni-Cd) OVA51022E OVA50283E P92688 11 W, 2G7 + ISC00648_01-2008_EN P92689 P92689 + + 29 Emergency light fittings No! No improvisation on safety! Domina Self-diagnosis version (Activa) IP 42 / IP 65, IK 08 P106258 The self-testing light fitting. P106259 A light fitting that provides information on how it is working, giving its status and, if there is a fault, the cause of the fault. 30 P106255 P106254 5. Self-diagnosis Self-testing light fitting that performs two types of diagnosis on one LED: 1. Tube verification. 2. Battery life check. ISC00648_01-2008_EN P106251 P106250 P106249 1. Quick installation Separate connector, safe and easy clip-on fitting. P106257 P106253 P106252 2. Safe and easy maintenance Click!! Easy access to the parts because the tube and the battery are incorporated in the actual reflector which can easily be removed. P101280 P98698 P98693 P98694 3. Versatile: an accessory for every type of installation The Domina model has various accessories for installing the light fitting in false ceilings, in electrical conduits, flush-mounted, surface-mounted, etc. Converts to an illuminated sign with an optional accessory. P106281 4. Remote control (optional) - Self-diagnosis synchronization. - Immediate test enable / disable. 7. Sealed version P106256 P106248 6. Pre-stamped holes for easy access Pre-stamped holes that are easy to drill through and 16 or 20 Ø tube inlet. ISC00648_01-2008_EN For places that need installation that is protected from moisture. 31 Domina (cont.) Emergency light fittings No! Self-diagnosis version (Activa) IP 42 / IP 65, IK 08 No improvisation on safety! Technical specifications P99858 b b b b b b b b b b b b e Self-diagnosis version (Activa) Available for maintained or non-maintained operation Installation for flush mounting and false ceiling Compliant with IEC EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42 or IP 65, IK 08 Insulation class: II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Light source: fluorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h for models with 1 h autonomy P99861 Dimensions Installation methods Dimensions (mm) P99863 Wall (installation without accessories) A B C 149 302 68 85, 145, 150, 400 and 169 640 lm 382 82 6/11 W 100, 140 and 210 lm 8/24 W Installation rules (examples for 85 and 640 lm) Flush (installation with flush mounting box) The photometric data is approximated (average values): for project calculations, scattering coefficients must be taken into consideration. P102888 Domina 85 lm Ceiling (installation without accessories) 3m 10.50 m False ceiling (installation with false ceiling kit + flush mounting box) Electrified track (installation with hanging / electrified track kit) 32 1 1 10.50 m 10.50 m Domina 640 lm P102889 Hanging (installation with hanging / electrified track kit) 1 1 3m 14.20 m 1 1 14.20 m 1 1 14.20 m ISC00648_01-2008_EN Product catalogue numbers Domina Protection rating Autonomy Average flux (lm) Lamp Consumption Ni-Cd battery (h) emergency maintained rated socket (VA) condition mode power (W) Weight Cat. no. (kg) Non-maintained P99858 IP 42 IP 65 IK 08 IK 08 1 100 - 6 G5 3.9 4.8 V 1.5 Ah 0.90 OVA37226E 140 - 6 G5 3.9 4.8 V 1.5 Ah 0.90 OVA37212E 150 - 8 G5 4.4 4.8 V 1.5 Ah 0.90 OVA37213E 210 - 11 2G7 5.5 6.0 V 1.5 Ah 1.00 OVA37216E 400 - 24 2G11 6.9 6.0 V 4.0 Ah 2.04 OVA37224E 640 - 24 2G11 6.9 6.0 V 4.0 Ah 2.04 OVA37217E 3 85 - 8 G5 3.7 9.6 V 1.5 Ah 1.30 OVA37215E 1 100 6 G5 3.9 4.8 V 1.5 Ah 0.90 OVA37227E 140 - 6 G5 3.9 4.8 V 1.5 Ah 0.90 OVA37218E 150 - 8 G5 4.4 4.8 V 1.5 Ah 0.90 OVA37219E 210 - 11 2G7 5.5 6.0 V 1.5 Ah 1.00 OVA37222E 400 - 24 2G11 6.9 6.0 V 4.0 Ah 2.04 OVA37225E 640 - 24 2G11 6.9 6.0 V 4.0 Ah 2.04 OVA37223E 3 85 - 8 G5 3.7 9.6 V 1.5 Ah 1.30 OVA37221E Maintained ISC00648_01-2008_EN IP 42 IK 08 1 145 240 8 G5 4.4 4.8 V 1.5 Ah 0.94 OVA37214E IP 65 IK 08 1 145 240 8 G5 4.4 4.8 V 1.5 Ah 0.94 OVA37220E 33 Emergency light fittings No! No improvisation on safety! Domina (cont.) Self-diagnosis version (Activa) IP 42 / IP 65, IK 08 Pictogram stickers (set of 10) P92688 P99857 Pictogram stickers (set of 10) P92689 Pictogram stickers (set of 10) P92690 Pictogram stickers (set of 10) P92687 Accessory catalogue numbers Dimensions (mm) Cat. no. height x width x depth Domina 6/11 W 130 x 227 OVA50267E Domina 8/24 W 150 x 310 OVA50272E Domina 6/11 W 130 x 227 OVA50268E Domina 8/24 W 150 x 310 OVA50273E Domina 6/11 W 130 x 227 OVA50269E Domina 8/24 W 150 x 310 OVA50274E Domina 6/11 W EN language 130 x 227 OVA50270E Domina 6/11 W ES language 130 x 227 OVA50271E Domina 8/24 W EN language 150 x 310 OVA50275E Domina 8/24 W ES language 150 x 310 OVA50276E Domina 6/11 W 152 x 295 x 50 OVA53021E Domina 8/24 W 172 x 375 x 57 OVA53022E P93016 Flush mounting box Compatibility Protective grids 34 P93007 P101280 Exit sign kits Teleur remote control All models OVA53023E All models OVA50347E P98693 P98694 Hanging / electrified track kit P98698 False ceiling kit (also order a flush mounting box) Domina 6/11 W 196 x 346 x 98 OVA53019E Domina 8/24 W 226 x 436 x 110 OVA53020E Domina 8/24 W Ceiling mounting OVA53024E Flag mounting OVA53025E Wall mounting OVA53026E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E Pictograms provided 130 x 336 ISC00648_01-2008_EN Spare parts catalogue numbers Fluorescent tubes Description Compatibility Cat. no. 6 W, G5 OVA37212E, OVA37218E, OVA37226E, OVA37227E OVA51037E OVA37214E, OVA37220E OVA51007E OVA37213E, OVA37215E, OVA37219E, OVA37221E OVA51041E 11 W, 2G7 OVA37216E, OVA37222E OVA51009E 24 W, 2G11 OVA37217E, OVA37223E, OVA37224E, OVA37225E OVA51042E 4.8 V, 1.5 Ah OVA37212E, OVA37213E, OVA37214E, OVA37018E, OVA37219E, OVA37220E, OVA37226E, OVA37227E OVA51016E 6.0 V, 1.5 Ah OVA37216E, OVA37222E OVA51019E 6.0 V, 4.0 Ah OVA37217E, OVA37223E, OVA37224E, OVA37225E OVA51039E 9.6 V, 1.5 Ah OVA37215E, OVA37221E OVA51040E Pictogram sticker set (4 pictograms for exit signs kit) P92687 P98733 Batteries (Ni-Cd) OVA50277E P92688 P98733 8 W, G5 + ISC00648_01-2008_EN P92689 P92689 + + 35 Emergency light fittings Rapida Standard version IP 42, IK 04 / 05 No! Quick installation, maximum integration. P106322 No improvisation on safety! P106324 Thanks to its removable base section and even design. P106318 5. Quality design P106316 6. Easy to fasten and align Diffuser specifically designed to achieve better quality illumination. The diffuser and the reflector have been developed to obtain greater luminous efficiency. 36 Several easy ways of fastening the light fitting and a wide horizontal and vertical cut-out for correct alignment. ISC00648_01-2008_EN Connectors integrated in the base section. P106313 P106312 P106316 1. Fast, easy installation Click!! Maximum speed, just one click and the base section and lamp are joined together. Click!! P106321 P106320 P106319 2. Safe and easy maintenance Easy access to the parts as the various elements are easy to remove. Safe and easy battery connection. P102832 P102898 P102897 P98698 3. Versatile: an accessory for every type of installation Accessories for installing the light fitting in false ceilings, surface-mounted, flush-mounted, flag, etc. Converts to an illuminated sign using methacrylate diffusers which are visible from 30 m. P106315 P106323 4. Perfect integration, sophisticated design It’s smooth, straight lines allow attractive integration in the most exacting surroundings. 8. Adapter, easy access P106314 P106317 7. Connection without any obstacles Separate base section for easy connection. ISC00648_01-2008_EN The light fitting includes an accessory for fitting a 16 or 20 Ø tube. 37 Rapida (cont.) Emergency light fittings Standard version IP 42, IK 04 / 05 No! No improvisation on safety! P99859 Technical specifications b b b b b b b b b b b e Available for maintained or non-maintained operation Installation: quick mounting on wall or ceiling Compliant with IEC EN 60598-2-22 standard Can be inhibited with rest mode via Teleur range of remote controls Protection rating: IP 42, IK 04 / 05 Insulation class: II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Light source: fluorescent lamp Power supply: 230 V, 50 Hz Complete recharge in 12 h P92718 Dimensions Dimensions (mm) B C 50 lm 120 284 52 8W 90 and 100 lm 120 360 52 Installation rules (examples with 50 and 100 lm) Installation methods The photometric data is approximated (average values): for project calculations, scattering coefficients must be taken into consideration. Wall (installation without accessories) Rapida 50 lm P102890 P99862 A 6W Flush (installation with flush mounting box) 3m 5.70 m 1 1 5.70 m Rapida 100 lm P102891 Ceiling (installation without accessories) 1 1 5.70 m 3m False ceiling (installation with false ceiling kit + flush mounting box) 38 7.10 m 1 1 7.10 m 1 1 7.10 m ISC00648_01-2008_EN Product catalogue numbers Rapida Protection rating Autonomy Average flux (lm) Lamp Consumption Ni-Cd battery Weight Cat. no. (h) (kg) emergency maintained rated power socket (VA) condition mode (W) Non-maintained P99859 IP 42 IK 04 1 IK 05 50 - 6 G5 4.5 2.4 V 1.5 Ah 0.80 OVA37576E 90 - 8 G5 4.5 3.6 V 1.5 Ah 0.85 OVA37577E 100 190 8 G5 4.5 3.6 V 1.5 Ah 0.90 OVA37578E Maintained IP 42 ISC00648_01-2008_EN IK 05 1 39 Emergency light fittings Rapida (cont.) Standard version IP 40, IK 04 / 05 No! No improvisation on safety! Dimensions (mm) Cat. no. height x width x depth Rapida 6 W 106 x 274 OVA50257E Rapida 8 W 106 x 350 OVA50262E Rapida 6 W 106 x 274 OVA50258E Rapida 8 W 106 x 350 OVA50263E P92689 Rapida 6 W 106 x 274 OVA50259E Rapida 8 W 106 x 350 OVA50264E Rapida 6 W EN language 106 x 274 OVA50260E Rapida 6 W ES language 106 x 274 OVA50261E Rapida 8 W EN language 106 x 350 OVA50265E Rapida 8 W ES language 106 x 350 OVA50266E Rapida 6 W 147 x 329 x 52 OVA53014E Rapida 8 W 147 x 405 x 52 OVA53015E Protective grids for flush mounting Rapida 6 W 201 x 364 x 41 OVA53012E Rapida 8 W 201 x 443 x 41 OVA53013E Protective grids for wall mounting Rapida 6 W 170 x 333 x 89 OVA50343E Rapida 8 W 180 x 393 x 89 OVA50344E Rapida 8 W Left and right OVA53016E Down OVA53017E Left + right + down OVA53018E Pictogram stickers (set of 10) Pictogram stickers (set of 10) Flag type bracket Teleur remote control 40 P102832 P102833 P102898 Exit sign kit (visibility 23 m) P93007 Exit sign kits (visibility 30 m) P98698 P98698 Flush mounting and false ceiling kit P102897 P99857 Pictogram stickers (set of 10) P92688 Pictogram stickers (set of 10) P92687 Compatibility P92690 Accessory catalogue numbers Rapida 8 W OVA53016E, OVA53017E, OVA53018E OVA53027E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E ISC00648_01-2008_EN Spare parts catalogue numbers Description Compatibility Cat. no. 6 W, G5 OVA37576E OVA51037E 8 W, G5 OVA37577E OVA51043E OVA37578E OVA51007E 2.4 V, 1.5 Ah OVA37576E OVA51012E 3.6 V, 1.5 Ah OVA37577E, OVA37578E OVA51013E ISC00648_01-2008_EN P92688 OVA50278E + P92689 Pictogram sticker set (4 pictograms for exit signs kit OVA53018E) P92687 Batteries (Ni-Cd) P92689 P98733 P98733 Fluorescent tubes + + 41 Emergency light fittings Guardian Standard version IP 65, IK 07 No improvisation on safety! Security guard in large spaces. P106302 No! High power and luminosity for buildings with high roofs. P106299 Fully recharged in 12 hours. P106299 5. Halogen lighting Provides up to 1050 lumens with two high performance halogen beams. P106300 6. Adjustable beams Two individually adjustable beams. Each halogen lamp turns around its axis from 90º to 45º so that they can be turned in any direction, both horizontal and vertical. 42 ISC00648_01-2008_EN P106304 P106303 1. Reliable installation Easy to connect and fit. P106297 P106298 2. Easy to maintain Easy to maintain and replace parts. P106301 P101285 3. Extremely robust to provide a high level of protection Ready for installation outside: IP 65. Robust: IK 07. P101279 4. Just one set The spotlight includes a mount for upright installation. ISC00648_01-2008_EN 43 Emergency light fittings Guardian (cont.) Standard version IP 65, IK 07 No! No improvisation on safety! Technical Specifications P93018 b Provided with 2 searchlights with halogen bulbs with high lighting performance (up to 1050 lm) b The searchlights rotate on their axis from 90° to 45° for pointing in any direction b Non-maintained emergency luminaires b Compliant with IEC EN 60598-2-22 standard b Can be inhibited with rest mode via Teleur range of remote controls b Protection rating: IP 65, IK 07 b Insulation class: II i b Operating temperature: 0…40°C b Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C b Power supply: 230 V, 50 Hz b Complete recharge in 12 h e P92728 P92693 Dimensions Dimensions (mm) A B C 287 434 168 2 x 10 W 200 lm 2 x 20 W 400 lm 287 434 168 2 x 50 W 1050 lm 280 440 230 The searchlights are vertically and horizontally adjustable Installation methods P101279 Wall (vertically) (installation without accessories) Wall (horizontally) (installation with support non provided) 44 ISC00648_01-2008_EN Product catalogue numbers Guardian Protection rating Autonomy Average flux (lm) Lamp (h) rated power (W) socket Consumption Pb battery (VA) Weight Cat. no. (kg) P93018 Non-maintained IP 65 IK 07 1 200 2 x 10 G4 30 6.0 V 7.2 Ah 3.40 OVA41437E 400 2 x 20 G4 27 12 V 7.2 Ah 4.60 OVA41435E 1050 2 x 50 GY6.35 37 2 x 12 V 7.2 Ah 7.50 OVA41436E Accessory catalogue numbers Teleur remote control Dimensions (mm) Cat. no. height x width x depth All models 118 x 118 x 20 OVA50342E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E Compatibility Description Cat. no. OVA41437E 6 V, 10 W OVA51002E OVA41435E 12 V, 20 W OVA51003E OVA41436E 12 V, 50 W OVA51004E OVA41437E 6 V, 7.2 Ah OVA51025E OVA41435E, OVA41436E 12 V, 7.2 Ah OVA51024E P98729 P93007 Protective grid (2 parts) Compatibility Lamps P101289 Spare parts catalogue numbers P101288 Batteries (Pb) ISC00648_01-2008_EN 45 Presentation Emergency exit signs P93013 Appropriate for all applications Hospital, school, etc. P101290 Hotel, office, etc. Easy to order and install Elegant, high-tech Very large size b round shape; b accessories for elegant integration; b LED light source: service life of up to 100,000 h b Visible up to 80 m P106363 b Delivred with: v 5 pictogram stickers to produce all single- and double-sided versions; v bracket for flag installation v cable gland Airport, shopping mall, railway station hall, etc. P101291 b They indicate the direction of evacuation and emergency exits in public places. b The international symbols are understandable by all types of public (foreigners, children, etc.). b Their intuitive understanding makes them very effective in case of panic. b These lighting units can be deactivated, by means of a Teleur remote control, during periods of building inactivity so as to: v ensure their satisfactory operation when the premises are open to the public, and v extend the service life of their batteries. P93011 Guide the public simply and effectively toward the exit P98736 No improvisation on safety! P98737 No! Self-diagnosis version (Activa) Some light fittings exist in a self-test version. Quick Signal and Astro Guida have such a version. They can make their operational diagnosis and tell whether the light source, the battery or the device is defective. The result of the diagnosis is displayed by a diode that flashes at an appropriate rate and in an appropriate colour. This makes it possible to save time, particularly during the test and maintenance stages. 46 ISC00648_01-2008_EN Range overview b IP 42, IK 06 24 m Cold cathode (40,000 h) 10 VA b IP 40, IK 07 28 m LED (100,000 h) 4.5 VA b b b b b b b b b b b b b P99875 P99874 Dimensions (mm) - h x w x (d) 213 x 261 x (35) The drawings are scale drawings IP 40 60 or 80 m Cold cathode (40,000 h) 15 VA 235 x 290 x (60) P99876 Installation methods Wall Ceiling False ceiling Hanging Electrified track Flag type bracket Maxi Slim P98689 P93012 Technical specifications Self-diagnosis Protection rating Visibility distance Light source Consumption Quick Signal P93160 Astro Guida Visibility: 60 m 443 x 644 x (80) P106364 Visibility: 80 m 523 x 804 x (80) Page ISC00648_01-2008_EN 48 52 56 47 Emergency exit signs No! No improvisation on safety! Astro Guida Self-diagnosis version (Activa), IP 42, IK 06 Standard version IP 42, IK 06 All-terrain signs. The self-testing exit sign An emergency exit sign that provides information on how it works, giving its status and, if there is a fault, the cause of the fault. P106366 Strong, versatile installation. Wall. Electrical conduit. Ceiling. Flag, etc. P106367 2. Self-diagnosis Suspended. Self-testing light fitting that performs two types of diagnosis on one LED: 1. Tube verification. 2. Battery life check. P106240 P106246 P106239 1. Practical installation Removable cover for easy connection. 48 P106243 P106242 P106241 Wall mount with cable guide to facilitate installation and subsequent connection. Personalization with easy to apply adhesive pictograms. ISC00648_01-2008_EN P106244 3. Quality Cold cathode ray tube as the light source, providing a product service life of more than 4 years. P106245 4. Just one set There is just one set with everything necessary for installation, including a pack of 5 pictograms and the mount for flag installation. ISC00648_01-2008_EN 49 Astro Guida (cont.) Emergency exit signs No! Self-diagnosis version (Activa), IP 42, IK 06 Standard version IP 42, IK 06 No improvisation on safety! P93012 Technical specifications b b b b b b b b b b b b b b b b e Self-diagnosis version (Activa) Cold cathode light source (working life of 40,000 h) Ni-Cd battery for high efficiency applications Long life, no maintenance needed Compliant with IEC EN 60598-2-22 standard Visibility distance of the sign in compliance with the new EN 1838 standard: 24 m Emergency exit sign operating in maintained modes Can be inhibited with rest mode via Teleur range of range remote controls 5 pictogram stickers included to create all single- and double-sided versions Bracket for flag installation included Protection rating: IP 42, IK 06 Class II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Power supply: 230 V, 50 Hz Complete recharge in 12 h for model with 1 h autonomy P93013 P92695 Dimensions Model All Dimensions (mm) A B C 213 261 35 Installation methods Wall (installation without accessories) P92992 P92993 Astro Guida with accessories included Ceiling (installation with kit not included) Hanging (installation with kit not included) Installation with flag type bracket (included) Electrified track (installation with kit not included) Flag type bracket (installation with accessories included) 50 ISC00648_01-2008_EN Emergency exit sign catalogue numbers Astro Guida screens included Visibility (m) Autonomy (h) Consumption (VA) Ni-Cd battery Weight (kg) Cat. no. 10 4.8 V 0.6 Ah 0.760 OVA38466E 1 10 4.8 V 0.6 Ah 0.760 OVA38464E 3 12 4.8 V 1.5 Ah 0.865 OVA38465E Self-diagnosis version P93012 Maintained 24 1 Standard version Maintained 24 Accessory catalogue numbers Compatibility Dimensions (mm) Cat. no. height x width x depth All models OVA50356E Protective grid IK 10 All models 248 x 296 x 53 OVA50357E All models, for 100 luminaires 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models, for 500 luminaires 90 x 71 x 60 4 mod. of 18 mm OVA50326E 116 x 229 OVA50281E 116 x 229 OVA50282E P98731 P98730 Ceiling, hanging and electrified track kit P93007 Teleur remote control P92690 For 1 or 2 sides signalling + P99857 + + + Spare parts catalogue numbers Cat. no. OVA50355E OVA50246E + P92689 Pictogram sticker set (5 pictograms for all singleand doublesided + versions) P92688 P92687 P92995 Flag bracket + + ISC00648_01-2008_EN 51 Quick Signal Emergency exit signs No! Self-diagnosis version (Activa), IP 40, IK 07 Standard version IP 40, IK 07 No improvisation on safety! Elegant design. The self-testing exit sign An emergency exit sign that provides information on how it works, giving its status and, if there is a fault, the cause of the fault. P106368 P106369 2. Self-diagnosis Methacrylate sign. Top quality rigid pictograms. LED technology. Most agreeable lighting. Self-testing light fitting that performs two types of diagnosis on one LED: 1. Tube verification. 2. Battery life check. P106305 1. Fast installation P106306 P106311 Wiring inlet box for easy connection of the removable connector. Click!! Click!! Wiring inlet box for easy connection of the removable connector. P106307 3. Clip-on pictograms Click!! A most attractive result. The pictograms do not stick to the light fitting’s methacrylate but clip onto it. 52 ISC00648_01-2008_EN P106309 P106310 4. Easy maintenance There are replacement batteries available. The battery can be changed easily by just opening the top cover. A brighter light that is less diffused (more directed) thanks to the use of 15 LEDs. Lasts a long time: more than eleven years’ service life. ISC00648_01-2008_EN 6. Reliable connection P106305 P106308 5. LED lighting Removable connector with identification to prevent incorrect connection. 53 Quick Signal (cont.) Emergency exit signs No! Self-diagnosis version (Activa), IP 40, IK 07 Standard version IP 40, IK 07 No improvisation on safety! P93160 Technical specifications b b b b b b b b b b b b b b b b e Self-diagnosis version (Activa) Long-lasting LED light source (100,000 h) Installation: quick mounting on wall, ceiling or flag Can be installed in false ceiling (with kit not included) Exit sign screens easy to install in precise position Compliant with IEC EN 60598-2-22 standard Visibility distance of the sign in compliance with the new EN 1838 standard: 28 m Emergency exit sign operating in maintained modes Can be inhibited with rest mode via Teleur range of range remote controls Brackets for wall/flag installation included Protection rating: IP 40, IK 07 Class II i Operating temperature: 0…40°C Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Power supply: 230 V, 50 Hz Complete recharge in 12 h for model with 1 h autonomy P92696 Dimensions Model All Dimensions (mm) A B C 235 290 60 P93017 P93010 P92996 Installation methods Wall (installation with accessories included) Ceiling (installation without accessories) Hanging (installation with kit not included) P93011 Quick fix installation with wall / flag type bracket (included) False ceiling (installation with kit not included) Installation with false ceiling mounting kit (not included) 54 Flag type bracket (installation with accessories included) ISC00648_01-2008_EN Emergency exit sign catalogue numbers Visibility (m) P101292 Quick Signal screens not included Autonomy (h) Consumption (VA) Ni-Cd battery Weight (kg) Cat. no. Self-diagnosis version Maintained 28 1 8.5 4.8 V 0.6 Ah 0.80 OVA38506E 1 8.5 4.8 V 0.6 Ah 0.80 OVA38504E 3 8.5 4.8 V 1.5 Ah 0.90 OVA38505E Standard version Maintained 28 Exit sign screen catalogue numbers Dimensions (mm) height x width Cat. no. 232 x 135 OVA50319E 232 x 135 OVA50320E 232 x 135 OVA50321E 232 x 135 OVA50322E 232 x 135 OVA50323E 232 x 135 OVA50324E 232 x 135 OVA53032E P92687 For 1 side signalling P92688 + P92689 + + For 2 sides signalling + P92690 + For 1 or 2 sides signalling P99857 + + + + Accessory catalogue numbers Compatibility All models All models OVA50314E P98732 False ceiling mounting kit Dimensions (mm) Cat. no. height x width x depth 97 x 324 x 85 OVA50318E P101293 Hanging kit P93007 Teleur remote control All models, for 100 luminaires 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models, for 500 luminaires 90 x 71 x 60 4 mod. of 18 mm OVA50326E Wall / flag type bracket ISC00648_01-2008_EN P101295 Batteries (Ni-Cd) P101302 Spare parts catalogue numbers Description Compatibility Cat. no. 4.8 V, 0.6 Ah OVA38504E, OVA51014E OVA38506E 4.8 V, 1.5 Ah OVA38505E OVA51015E All models OVA50316E 55 Maxi Slim Emergency exit signs Standard version IP 40, 60/80 m visibility No! No improvisation on safety! P101290 Visible from quite a distance. P101296 1. High technology light source P103016 Used for 60 or 80 metre visibility distances. Cold cathode light source. P101291 2. Wall or ceiling mounting Easy to adapt without the help of accessories. 56 ISC00648_01-2008_EN P103017 P101277 3. Easy to adapt P1030018 Three kinds of screens can be adapted: left, right and straight. Protection grid. ISC00648_01-2008_EN 57 Maxi Slim (cont.) Emergency exit signs Standard version IP 40, 60/80 m visibility No! No improvisation on safety! P98689 Technical specifications b Visibility distance of the sign in compliance with the new EN 1838 standard: 60 m for M60 and 80 m for M80. b Cold cathode light source (working life of 40,000 h) b Ni-Cd battery for high efficiency applications b Compliant with IEC EN 60598-2-22 standard b Emergency exit sign operating in maintained mode b Can be inhibited with rest mode via Teleur range of range remote controls b Installation even on flammable surfaces b Protection rating: IP 40 b Class I b Operating temperature: 0…40°C b Power supply: 230 V, 50 Hz b Complete recharge in 12 h for models with 1 h autonomy e P98690 Dimensions Model Visibility Dimensions (mm) A B C M60 60 m 443 644 80 M80 80 m 523 804 80 P98691 Installation methods Wall (installation without accessories) Hanging (chain not included) Ceiling (installation without accessories) 58 ISC00648_01-2008_EN Emergency exit sign catalogue numbers Maxi Slim screens not included Model Visibility (m) Autonomy (h) Consumption (VA) Ni-Cd battery Weight (kg) Cat. no. 1 15 6.0 V 1.5 Ah 4.290 OVA38072E 3 15 6.0 V 1.5 Ah 4.740 OVA38073E 1 15 6.0 V 4.0 Ah 5.150 OVA38074E 3 15 6.0 V 4.0 Ah 5.600 OVA38075E Maintained P101277 M60 M80 60 80 Exit sign screen catalogue numbers Cat. no. for M60 M80 For 1 side signalling P92687 OVA53000E OVA53005E + P92688 OVA53001E OVA53006E + P92689 OVA53002E OVA53007E + For 2 sides signalling OVA53003E OVA53008E + OVA53004E OVA53009E + Accessory catalogue numbers Dimensions (mm) Cat. no. height x width x depth M60 550 x 680 x 100 OVA53010E M80 630 x 840 x 100 OVA53011E All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E Teleur remote control P93007 P98692 Protective grids Compatibility Spare parts catalogue numbers Description Compatibility Cat. no. 6.5 W OVA38072E, OVA38073E OVA51034E 7.5 W OVA38074E, OVA38075E OVA51035E 6.0 V, 1.5 Ah OVA38072E, OVA38073E OVA51019E 6.0 V, 4.0 Ah OVA38074E, OVA38075E OVA51039E Ni-Cd batteries ISC00648_01-2008_EN P101297 P101296 Fluorescent tubes 59 Presentation Conversion kits P90841 Convert ordinary fluorescent tubes into self-contained emergency luminaires P101314 No improvisation on safety! P101573 No! P93023 b These devices power the standard fluorescent lighting in the event of a mains failure to provide a sufficient lighting level. As a result: v all panic is avoided; v the path and obstacles are made visible for movements in complete safety. Compatible with many tubes Workshop, factory, etc. Garage, warehouse, etc. P101298 Office, corridor, clean room, etc. Invisible P101299 Straight tubes, circular tubes, compact tubes (but only with 4-pin connector) 2D type tubes Concealed in the fluorescent tube luminaire. 60 ISC00648_01-2008_EN Range overview Technical specifications Suitable for fluorescent tubes up to Duration Compatibility with ballast electromagnetic electronic Can be inhibited with rest mode via remote control Page 58 W 1 h minimum b Everlux Power P93023 P93022 Everlux Ferro b 70 W 3 h minimum b b b 62 64 Warning: Trained personnel must be used to install these products ISC00648_01-2008_EN 61 Conversion kits Everlux Ferro Standard version No! No improvisation on safety! P93022 Technical specifications e b b b b b b b b b b b b Warning: Trained personnel must be used to install these products Suitable for fluorescent tubes up to 58 W Compatible only with electromagnetic ballasts Screw terminals Compliant with EN 61347-2-7 standard Can be inhibited with rest mode via remote control Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Class II i Power supply: 230 V, 50 Hz Mains presence indicator (LED) Ni-Cd battery, in line or side by side Complete recharge in 24 h Tubes % emergency flux (1) and duration according to the conversion kit Socket Lamp G5 4W OVA43101E OVA43103E OVA43105E or OVA43102E or OVA43104E 30% / 1 h 30 26% / 3 h 25% / 2 h 6W 30% / 1 h 30 30% / 3 h 30% / 2 h - 8W 25% / 1 h 30 25% / 3 h 30% / 1 h 30 - 13 W 14 W FHE T5 21 W FHE T5 24 W FHO T5 28 W FHE T5 35 W FHE T5 49 W FHO T5 54 W FHO T5 2x8W 18 W 36 W 2 x 18 W 58 W 22 W 32 W 40 W 10 W 16 W 28 W 38 W GE 10 W 13 W 18 W 26 W 32 W 5W 7W 9W 11 W 36 W 18 W 24 W 36 W 40 W 55 W 25% / 1 h 15% / 1 h 25% / 1 h 19% / 1 h 20% / 1 h 13% / 1 h 24% / 1 h 30 22% / 1 h 30 21% / 1 h 30 18% / 1 h - 25% / 2 h 25% / 2 h 30 25% / 2 h 17% / 2 h 30 20% / 1 h 30 23% / 1 h 32% / 1 h 30 17% / 2 h 18% / 1 h 20% / 1 h 13% / 2 h 12% / 1 h 30 25% / 2 h 23% / 1 h 30 15% / 1 h 20% / 3 h 21% / 2 h 17% / 2 h 15% / 1 h 30 10% / 1 h 30 24% / 3 h 22% / 3 h 21% / 3 h 17% / 2 h 14% / 1 h 30 13% / 2 h 18% / 1 h 30 16% / 1 h - 19% / 1 h 30 20% / 1 h 30 14% / 1 h 12% / 1 h 30 20% / 1 h 8% / 1 h 30 9% / 1 h 27% / 1 h 30 20% / 1 h 17% / 1 h 23% / 1 h 30 16% / 1 h 30 35% / 2 h 30 30% / 2 h 26% / 1 h 30 18% / 1 h 30 8% / 1 h 30 - 25% / 2 h 30 23% / 2 h 18% / 2 h 30 20% / 1 h 13% / 1 h 30 7% / 1 h 30 25% / 2 h 11% / 1 h 30 12% / 1 h 18% / 1 h 30 10% / 1 h 10% / 1 h 30 10% / 1 h 18% / 1 h 30 13% / 1 h 25% / 1 h 30 14% / 1 h 30 12% / 1 h 30 11% / 2 h 34% / 3 h 33% / 2 h 30 10% / 2 h 18% / 1 h 30 10% / 1 h 30 10% / 1 h 30 10% / 1 h 8% / 1 h G13 G10q GR10q G24q Gx24q 2G7 2G10 2G11 OVA43106E - (1) In emergency mode, the luminaire powered by the kit provides a percentage of its nominal flux (typically around 10 %). 62 ISC00648_01-2008_EN Dimensions Batteries P92697 Circuit Model Dimensions (mm) Circuit Battery A B C D E F G H J OVA43101E 157 32.5 140 40.5 - - 26 75 50 OVA43102E 157 32.5 140 40.5 165 35 28 - - OVA43103E 157 32.5 140 40.5 - - 33 96 62 OVA43104E 157 32.5 140 40.5 210 39 35 - - OVA43105E 157 32.5 140 40.5 165 35 28 - - OVA43106E 157 32.5 140 40.5 210 39 35 - - Conversion kits Everlux Ferro Mains load Weight Ni-Cd battery (VA) (kg) Cat. no. P93022 Maintained and non-maintained 5 0.46 3.6 V 2 Ah side by side OVA43101E 5 0.65 3.6 V 4 Ah side by side OVA43103E in line OVA43104E 4.5 0.46 3.6 V 2 Ah in line OVA43105E 7 0.65 3.6 V 4 Ah in line OVA43106E Compatibility Cat. no. in line OVA43102E Spare parts catalogue numbers 3.6 V in line OVA43102E, OVA43105E OVA51026E 2 Ah side by side OVA43101E OVA51027E Batteries Ni-Cd LED P101300 P101301 3.6 V in line OVA43104E, OVA43106E OVA51028E 4 Ah side by side OVA43103E OVA51029E All models OVA51033E Teleur remote control ISC00648_01-2008_EN P93007 Accessory catalogue numbers Compatibility Dimensions (mm) Cat. no. height x width x depth All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E 63 Conversion kits Everlux Power Standard version No! No improvisation on safety! P93023 Technical specifications e b b b b b b b b b b b b Warning: Trained personnel must be used to install these products Suitable for fluorescent tubes up to 70 W Fully compatible with both electromagnetic and electronic ballasts Quick-connect terminal strips Compliant with EN 61347-2-7 standard Can be inhibited with rest mode via remote control Fire behaviour (IEC 60695-2-10), incandescent wire: 850°C Class II i Power supply: 230/240 V, 50/60 Hz ± 10% Mains presence indicator (LED) Ni-Cd battery, in line Complete recharge in 24 h Tubes P93024 Socket G5 G13 G10q 2GX13 GR10q Quick-disconnect terminal strips G24q Gx24q 2G7 2G10 2G11 % emergency flux (1) and duration according to the conversion kit Lamp 8W 14 W FHE T5 T5 GE 21 W FHE T5 T5 GE 24 W FHO T5 28 W FHE T5 T5 GE 39 W FHO T5 54 W FHO T5 18 W Philips 36 W 58 W 70 W 22 W 32 W 40 W 22 W Philips 40 W 10 W 16 W 28 W GE 38 W GE 55 W 10 W 13 W 18 W 26 W 18 W 26 W 32 W 42 W 7W 9W 11 W 18 W 24 W 36 W 18 W 24 W 36 W Philips 40 W Philips GE 55 W OVA43107E 10% / 6 h 10.7% / 4 h 12.3% / 3 h 11.4% / 3 h 5.8% / 4 h 6.1% / 4 h 6% / 4 h 5% / 3 h 5% / 4 h 4.8% / 3 h 6% / 3 h 30 11% / 4 h 30 11% / 4 h 6,7% / 3 h 5,8% / 3 h 30 9% / 5 h 10.7% / 4 h 7.7% / 4 h 6.5% / 3 h 30 7.7% / 4 h 5.7% / 3 h 5.6% / 3 h 12.4% / 6 h 30 10.5% / 5 h 13% / 4 h 4.4% / 4 h 4.5% / 4 h 4.4% / 3 h 4% / 4 h 5.8% / 4 h 5% / 3 h 4.2% / 3 h - OVA43108E 12.1% / 5 h 12% / 5 h 13.8% / 3 h 30 7% / 4 h 6.9% / 3 h 6.6% / 4 h 6.9% / 3 h 5.1% / 3 h 5.5% / 4 h 30 5.8% / 4 h 6.3% / 3 h 13% / 5 h 13,7% / 4 h 7,1% / 4 h 5% / 3 h 30 5.3% / 3 h 30 3% / 3 h 12% / 6 h 14.6% / 5 h 9.4% / 4 h 8% / 4 h 9.4% / 4 h 7.8% / 3 h 30 7.4% / 3 h 13.3% / 6 h 16.4% / 5 h 5.8% / 4 h 4.7% / 4 h 6.3% / 4 h 5.3% / 3 h 30 7% / 3 h 6.1% / 3 h 4.3% / 3 h 4.9% / 3 h OVA43109E 10% / 6 h 14.7% / 4 h 7% / 5 h 15% / 3 h 16% / 3 h 6.6% / 4 h 6.6% / 3 h 8.1% / 5 h 8.3% / 4 h 5.8% / 3 h 30 5.6% / 3 h 7.5% / 5 h 6.8% / 4 h 8% / 4 h 8% / 4 h 16,3% / 5 h 8,9% / 4 h 7% / 4 h 4% / 3 h 30 9.4% / 5 h 8.5% / 4 h 9.4% / 5 h 8.8% / 4 h 8.1% / 4 h 8.3% / 3 h 6% / 5 h 5.8% / 4 h 6.8% / 5 h 6.5% / 4 h 8% / 4 h 5.5% / 3 h 7% / 4 h (1) In emergency mode, the luminaire powered by the kit provides a percentage of its nominal flux (typically around 10 %). 64 ISC00648_01-2008_EN P92698 Dimensions Circuit Batteries Model Dimensions (mm) Circuit Battery A B C D E F G OVA43107E 230 28 220 40 210 39 35 OVA43108E 230 28 220 40 275 39 35 OVA43109E 230 28 220 40 332 39 35 Conversion kits Everlux Power Mains load (VA) Ni-Cd battery in line Weight (kg) Cat. no. P93023 Maintained and non-maintained 5.5 3.6 V 4.5 Ah 0.63 OVA43107E 6 4.8 V 4.5 Ah 0.76 OVA43108E 6.5 6.0 V 4.5 Ah 0.85 OVA43109E Spare parts catalogue numbers P101294 Ni-Cd batteries Compatibility Cat. no. 3.6 V - 4.5 Ah OVA43107E OVA51030E 4.8 V - 4.5 Ah OVA43108E OVA51031E 6.0 V - 4.5 Ah OVA43109E OVA51032E All models OVA51033E P101301 LED Teleur remote control ISC00648_01-2008_EN P93007 Accessory catalogue numbers Compatibility Dimensions (mm) Cat. no. height x width x depth All models (for 100 luminaires) 102 x 77 x 81 4.5 mod. of 18 mm OVA50325E All models (for 500 luminaires) 90 x 71 x 60 4 mod. of 18 mm OVA50326E 65 Presentation Portable emergency lamps Lantern function Thanks to its movable beam and stable base, you can work comfortably, keeping your hands free. 66 P101308 Outdoor emergency response (breakdown service, search and rescue, etc.) P101312 More than a simple portable lamp P101311 Guarding, security applications, etc. Police, fire fighters, etc. P101308 Emergency response in good conditions P101309 No improvisation on safety! P101310 No! Revolving light function using diffuser signaller accessory associated with flash function Emergency lighting function switches on automatically in case of mains failure when plugged into a power outlet ISC00648_01-2008_EN Range overview Page ISC00648_01-2008_EN IP 40 5.5 W (xenon) 3h 320 lux at 2 m 1.5 W (incandescent) 15 h 5 lux at 1 m 10 VA Pb IP 55 10 W (halogen) 1 h 30 490 lux at 2 m 1.5 W (incandescent) 15 h 5 lux at 1 m 10 VA Pb 68 68 Jodiolux P93033 P93031 Consumption Battery Toplux P93029 Technical specification Protection rating Rated power, main autonomy lamp and Illumination auxiliary lamp Top 4 10 W (halogen) 4h 490 lux at 2 m 1.5 W (incandescent) 24 h 5 lux at 1 m Ni-Cd IP 65, IK 07 10 W (halogen) 4h 1300 lux at 2 m 1.5 W (incandescent) 24 h 4 lux at 1 m 6.5 VA Ni-Cd 68 67 Portable emergency lamps No! No improvisation on safety! Top 4 Toplux Jodiolux High quality lamps. 2. Direct recharging from the mains 3. Optional charger Operation equivalent to a normal emergency light. While it is connected to the mains (230 V), the lamp will come on automatically if there is a power failure. Can be recharged directly from the mains through the cable supplied with the product. Recharge time: 24 hours. An optional 12/24 V DC charger can be connected for charging the lamps (in cars for example). P106262 1. Automatic lighting Top 4 Jodiolux IP 40. Battery operation 4-12 hrs. Provides 320 lux at 2 m. Cable incorporated inside. P106266 P106264 IP 65. Battery operation 4-24 hrs. Provides 1300 lux at 2 m. 68 ISC00648_01-2008_EN All models have 2 light sources that are capable of constant operation (for searching) or flashing (for indicating), with a switch for each of the functions. The lamps have handles on the top so that the product is easier to handle and carry. 7. Variety of tones P106260 6. Directable P106267 P106261 5. Ergonomic P106265 All of the models have a directable beam to assist working. Different coloured filters included with each model. Toplux P106268 IP 55. Battery operation 2-15 hrs. Provides 490 lux at 2 m. P93036 P106263 4. Double indication Anti-fog diffuser (Toplux and Top 4) ISC00648_01-2008_EN 69 Top 4 Portable emergency lamps No! IP 40 No improvisation on safety! P93029 Presentation b Top 4 is an emergency spotlight with rechargeable lead batteries and 2 lamps: one 5.5 W xenon lamp and one incandescent 1.5 W lamp. b Ideal for night watches, rescue and similar purposes. Top 4 can also be used as an emergency lamp, thanks to the diffuser-signaller with flashing function on both lamps. b Rugged: designed for heavy-duty applications and made from highly resistant materials. b Rechargeable directly from 230 V supply. The main cable is situated inside the optical unit. b When plugged on power supply, it can switch on automatically when the mains falls. b Versatile: Top 4 can be used as a lantern thanks to the adjustable beam b Optional charger available to recharge Top 4 from car battery. Technical Specifications b b b b b b Both lights can flash Protection rating: IP 40 Class II i Operating temperature: -10…40°C Recharge: 230 V, 50 Hz, recharging time: 24 h Autonomy: 3 h (main light) and 15 h (auxiliary light) Diagram 1m e P93030 P93035 5 lx 320 lx 2m Product catalogue numbers Rated power, type and autonomy main lamp Lamp and 4 colour filters (included) Consumption Pb (VA) battery auxiliary lamp 5.5 W - xenon - 3 h 1.5 W - incandescent - 15 h 10 6V Weight Cat. no. (kg) 4 Ah 1.9 OVA41317E Accessory catalogue numbers Cat. no. P93163 Lamp supports P93036 Diffuser signaller P93159 Charger These accessories are made of painted steel and are useful for fixing the portable lamps to the wall, on motor vehicles, boats, etc., to place units in a handy position. OVA50360E Manufactured to solve the problem of circular signalling, this diffuser is used with Top 4 flashing lamps. It is suitable for use in case of fog, danger, etc. and can be used where 360° lighting is needed. Ideal for fire brigades, construction yards, police, boats, rescue applications, etc. OVA50315E This is used to recharge the portable emergency lamps from 12/24 V DC. Maximum output power: 10 VA (excluding capacitive loads). Output voltage: 220 V, 50 Hz. Dimensions: 65 x 95 x 100 mm. OVA50358E Spare parts catalogue numbers Cat. no. 6V - 4 Ah - Pb OVA51023E xenon - 6 V - 0.9 A - E10 OVA51001E 6V - 1.5 W OVA51000E P101304 Battery P101305 P101307 Lamps 70 ISC00648_01-2008_EN Toplux IP 55 P93031 Presentation b Toplux is a professional rechargeable searchlight resistant to heavy rain (IP 55). b Ideal for military, police, rescue and security applications. Toplux can also be used as an emergency lamp, thanks to the diffuser-signaller with flashing function on both lamps. b It is fitted with two lamps: one powerful iodine lamp (10 W) and one incandescent lamp (1.5 W). b Long distance light beam with range of more than 200 m. b Rechargeable directly from 230 V supply. b When plugged into a power outlet, it can switch on automatically in case of mains failure. b An electronic circuit prevents batteries from discharging completely. b Versatile: Toplux can be used as a lantern thanks to the adjustable beam b Optional charger available to recharge Toplux from car battery. Technical Specifications b b b b b b v v e Both lights can flash Protection rating: IP 55 (special rubber gaskets) Class II i Operating temperature: -10…40°C Recharge: 230 V, 50 Hz, recharging time: 24 h Autonomy: 1 h 30 (main light) and 15 h (auxiliary light) 4 h (main light) and 24 h (auxiliary light) Diagram P93032 P93035 1m 5 lx 490 lx 2m Product catalogue numbers Lamp and included accessories (mains cable, 4 colour filters and shoulder carrying strap) Rated power, type and autonomy main lamp auxiliary lamp 10 W - halogen 1.5 W 1 h 30 incandescent - 15 h 10 W - halogen 1.5 W 4h incandescent - 24 h Spare parts catalogue numbers 6 V - 4 Ah - Pb P93163 Lamp supports OVA51036E P93036 P101306 Diffuser signaller 6 V - 7 Ah - Ni-Cd P101305 P101289 halogen - 6 V - 10 W OVA51002E 6 V - 1.5 W ISC00648_01-2008_EN OVA51000E P93159 Charger Lamps 10 10 Pb 6V Ni-Cd 6V Weight Cat. no. (kg) 4 Ah 2.0 OVA41318E 7 Ah 2.4 OVA41319E Accessory catalogue numbers Cat. no. OVA51023E P101304 Batteries Consumption Battery (VA) These accessories are made of painted steel and are useful for fixing the portable lamps to the wall, on motor vehicles, boats, etc., to place units in a handy position. Manufactured to solve the problem of circular signalling, this diffuser is used with Top 4 flashing lamps. It is suitable for use in case of fog, danger, etc. and can be used where 360° lighting is needed. Ideal for fire brigades, construction yards, police, boats, rescue applications, etc. This is used to recharge the portable emergency lamps from 12/24 V DC. Maximum output power: 10 VA (excluding capacitive loads). Output voltage: 220 V, 50 Hz. Dimensions: 65 x 95 x 100 mm. Cat. no. OVA50360E OVA50315E OVA50358E 71 Portable emergency lamps No! Jodiolux IP 65, IK 07 No improvisation on safety! P93033 Presentation b Jodiolux is a portable professional searchlight provided with high-performance emergency functions and resistant to heavy rain (IP 65). b Ideal for military, police and rescue applications. b It is fitted with two lamps: a powerful iodine lamp (10 W) for high-power lighting, and a small incandescent bulb (1.5 W) for economy lighting. b Long distance light beam with range of 300 m. b Rechargeable directly from 230 V supply. b When plugged into a power outlet, it can switch on automatically in case of mains failure. b Versatile: Jodiolux can be used as a lantern thanks to the adjustable beam b Optional charger available to recharge Jodiolux from car battery. Technical Specifications e b b b b b b b b Case of nylon Compliant with EN 60598-2-8 standards Both lights can flash Protection rating: IP 65 (special rubber gaskets), IK 07 Class II i Operating temperature: -10…40°C Recharge: 230 V, 50 Hz, recharging time: 24 h Autonomy: 4 h (main light) and 24 h (auxiliary light) Diagram 1m 4 lx 1300 lx 2m P93034 Product catalogue numbers Rated power, type and autonomy main lamp auxiliary lamp 10 W - halogen 1.5 W - incandescent 4h 24 h Consumption Ni-Cd battery (VA) Weight Cat. no. (kg) 6.5 2.1 6V 7 Ah OVA41033E Accessory catalogue numbers Cat. no. P101303 Lamp supports Lamp and included accessories (mains cable, 4 colour filters and shoulder carrying strap) P93159 Charger These accessories are made of painted steel and are useful for fixing the portable lamps to the wall, on motor vehicles, boats, etc., to place units in a handy position. OVA50359E This is used to recharge the portable emergency lamps from 12/24 V DC. Maximum output power: 10 VA (excluding capacitive loads). Output voltage: 220 V, 50 Hz. Dimensions: 65 x 95 x 100 mm. OVA50358E Spare parts catalogue numbers Cat. no. 6 V - 7 Ah - Ni-Cd OVA51020E halogen - 6 V - 10 W OVA51002E 6 V - 1.5 W OVA51000E P101305 Lamps P101289 P101306 Battery 72 ISC00648_01-2008_EN Teleur Remote control Ensure satisfactory operation of the lighting units when the premises are open to the public, and save the batteries during long periods of inactivity. P101577 No improvisation on safety! P101576 No! School, gymnasium, auditorium, etc. Shop, office, etc. Presentation P93007 The remote control is used mainly to inhibit emergency operation. The emergency lights and escape route fittings can be switched off when the mains power is off (e.g. when the building is not occupied). It is also used during maintenance operations to switch the emergency light devices on or off. When the mains power is restored, the emergency lights and escape route fittings are automatically reset. They are ready to operate in the event of another black-out. Safety conditions are fully complied with in the building. Advantages Teleur e b Battery endurance is preserved (to ensure maximum autonomy when mains power is restored). The fittings are ready to operate, even after long periods of inactivity. b Longer battery life. Using a Teleur avoids a proof discharge. b Teleur ensures compliance with recent European standards IEC EN 60598-2-22. Technical specifications P93008 Teleur Input Teleur 500 220 / 230 V - 50 / 60 Hz Consumption 2.5 VA Minimum recharging time 24 h 3.5 VA Discharge time Over 200 emergency lamp switchings (with no current from the mains) Case Self-extinguishing polycarbonate (PC) UL 94 V2 Insulation Double insulated Fire behaviour (IEC 60695-2-10) 650°C incandescent wire Teleur 500 e height 102 90 width 77 71 depth 81 60 Width in 18 mm modules 4.4 4 Maximum number of luminaires for each Teleur 100 500 Maximum distance from remote control to luminaires Approximately 500 m Minimum cable size 1 mm2 with 100 luminaires Batteries 5 x 1.2 V, 500 mAh, Ni-Cd Dimensions (mm) Product catalogue numbers Weight (kg) Cat. no. ISC00648_01-2008_EN Teleur 0.30 OVA50325E Teleur 500 0.30 OVA50326E 73 74 ISC00648_01-2008_EN Technical guide No! Contents No improvisation on safety! ISC00648_01-2008_EN Lighting and safety signs 76 Introductory information 76 Design 77 Presentation, standards 77 The 5 main stages 78 System types 81 Emergency light fittings spacing table 82 Connection principle for conversion kits 90 Maintenance 94 Periodic checks and maintenance 94 Glossary 96 Emergency lighting glossary 96 75 Technical guide Lighting and safety signs Introductory information No! No improvisation on safety! Emergency lighting and other systems When we refer to emergency lighting, we mean the auxiliary lighting that is triggered when the standard lighting fails. Emergency lighting is subdivided as follows (EN-1838): Safety lighting It originates from the emergency lighting and is intended to provide lighting for people to evacuate an area safely or for those who try to finish a potentially dangerous operation before leaving the area. It is intended to illuminate the means of evacuation and ensure continuous visibility and ready usage in safety when standard or emergency lighting is needed. Safety lighting may be further subdivided as follows: Safety lighting for escape routes Anti-panic lighting in extended areas It originates from the safety lighting, and is intended to ensure that the escape means can be clearly identified and used safely when the area is busy. It originates from the safety lighting, and is intended to avoid panic and to provide the necessary lighting to allow people to reach a possible escape route area. Emergency lighting and safety signs for escape routes The emergency lighting and safety signs for escape routes are very important for all those who design emergency systems. Their suitable choice helps improve safety levels and allows emergency situations to be handled better. Standard EN 1838 ("Lighting applications. Emergency lighting") gives some fundamental concepts concerning what is meant by emergency lighting for escape routes: "The intention behind lighting escape routes is to allow safe exit by the occupants, providing them with sufficient visibility and directions on the escape route …" The concept referred to above is very simple: the safety signs and escape route lighting must be two separate things. Functions and operation of the luminaires The manufacturing specifications are covered by standard EN 60598-2-22, "Particular Requirements - Luminaires for Emergency Lighting", which must be read with EN 60598-1, "Luminaires – Part 1: General Requirements and Tests". Duration A basic requirement is to determine the duration required for the emergency lighting. Generally it is 1 hour but some countries may have different duration requirements according to statutory technical standards. Operation We should clarify the different types of emergency luminaires: b Non-maintained luminaires v The lamp will only switch on if there is a fault in the standard lighting v The lamp will be powered by the battery during failure v The battery will be automatically recharged when the mains power supply is restored b Maintained luminaires v The lamp can be switched on in continuous mode v A power supply unit is required with the mains, especially for powering the lamp, which can be disconnected when the area is not busy v The lamp will be powered by the battery during failure. 76 ISC00648_01-2008_EN Design Presentation, standards Introduction The integration of emergency lighting with standard lighting must comply strictly with electrical system standards in the design of a building or particular place. All regulations and laws must be complied with in order to design a system which is up to standard. P93161 The main functions of an emergency lighting system when standard lighting fails are the following: b Clearly show the escape route using clear signs. b Provide sufficient emergency lighting along the escape paths so that people can safely find their ways to the exits. b Ensure that alarms and the fire safety equipment present along the way out are easily identifiable. European standards The design of emergency lighting systems is regulated by a number of legislative provisions that are updated and implemented from time to time by new documentation published on request by the authorities that deal with European and international technical standards and regulations. Each country has its own laws and regulations, in addition to technical standards which govern different sectors. Basically they describe the places that must be provided with emergency lighting as well as its technical specifications. The designer's job is to ensure that the design project complies with these standards. EN 1838 A very important document on a European level regarding emergency lighting is the Standard EN 1838, "Lighting applications. Emergency lighting". This standard presents specific requirements and constraints regarding the operation and the function of emergency lighting systems. CEN and CENELEC standards With the CEN (Comité Européen de Normalisation) and CENELEC standards (Comité Européen de Normalisation Electrotechnique), we are in a standardised environment of particular interest to the technician and the designer. A number of sections deal with emergencies. An initial distinction should be made between luminaire standards and installation standards. EN 60598-2-22 and EN-60598-1 Emergency lighting luminaires are subject to European standard EN 60598-2-22, "Particular Requirements - Luminaires for Emergency Lighting", which is an integrative text (of specifications and analysis) of the Standard EN-60598-1, Luminaires – "Part 1: General Requirements and Tests". ISC00648_01-2008_EN 77 Design (cont.) Technical guide The 5 main stages No! No improvisation on safety! The lighting design Certain fundamental elements must be considered for the initial stage of the design job. One of the more important is the plan of the area which is used to determine: b The areas to light. It is also important to consider the position of the fire safety points on the plan to project the area properly. b The exit paths to see if they are escape routes or open spaces. b Areas outside the exit paths such as lifts, toilets and plant rooms. b Outside areas, to determine the lighting necessary outside the exit. b Luminaire operating mode, maintained or non-maintained. b During operation, 1 hour or 3 hours according to the applicable standards. In order to identify these areas, it is very important to apply certain principles based on safety logic, taking points from the EN 1838 standard. In addition, the standard is fundamental to decide where and how to install the luminaires for the emergency lighting. The national laws should be used to decide the lighting parameters for the different areas. Design stages The following diagram can be used to simplify the various steps taken to perform design: Stage 1 at the safety exits and depending on where the safety signs are installed near every first-aid zone 78 near every change in floor level P93483 P93482 near the stairs so that each step receives direct light at each point where there is a change of direction P93487 near and immediately outside each exit P93486 P93485 P93484 at every exit door planned to be used in an emergency P93481 P93480 P93479 Install the luminaires and the safety signs where necessary b Standard 1838, section 4.1, requires the luminaires to be installed at least 2 metres from the floor. This is so that they can be seen if the area needs to be evacuated; the same paragraph explains where and how to install the emergency system luminaires. b Installation of the luminaire signs and safety lighting according to EN-1838. at every corridor intersection near every fire safety device and call point ISC00648_01-2008_EN P92687 Stage 2 P92688 Safety signs for escape routes b It is very important for the best escape route be very clearly marked, allowing fast and safe evacuation of the areas and the buildings. b The effectiveness of the sign basically depends on the size, the colour, the placing and how well the sign can be seen. b European standards have established that word formats, for example "EXIT", should now be considered obsolete, and have decided in favour of pictograms which show a design in white with a green background (the so-called "running man"). P92689 Maximum viewing distance b It is important to ensure that the signs which mark the escape routes are visible from all sides. This depends on the size of the sign as well as its position. b To this end, the regulations provide the following formula: d = s x p, where: v "d" is the maximum viewing distance v "p" is the height of the pictogram v "s" = 100 for externally lighted signs = 200 for internally lighted signs P93162 P93166 The most common format Typical example of measuring position ISC00648_01-2008_EN 79 Design (cont.) Technical guide The 5 main stages (cont.) No! No improvisation on safety! Stage 3 Safety lighting for escape routes b Where the escape routes are up to 2 m wide (according to EN 1838), luminaires must be provided to ensure a minimum level of lighting of 1 lux on the floor along the central line of the escape path. b The lighting should not be less than 0.5 lux along the central section which should not be less than half the width of the escape path. P93167 Example: 2 m wide corridor 1 lux 1m (u 0.5 lux) In some countries there are country-specific divergences that replace the European standard regulations. Anti-panic area lighting b For open areas or those crossed by escape routes, commonly known as Extended Areas or Anti-panic areas, a minimum value of 0.5 lux horizontal lighting on the floor must be guaranteed on the whole non-covered area, excluding a section of 0.5 m on the edge of the area. b The other parameters are similar to those already referred to for lighting escape routes. P93168 Stage 4 b Two notes notes in EN 1838 comment on this topic. v "Note 1: wider escape routes must be considered as groups of 2 m wide routes or else be provided with lighting for extended areas (anti-panic). v Note 2: countries that require different levels of lighting are listed in appendix B." b Emergency luminaire response time should be 0.5 seconds. 50% of the minimum lighting required should be supplied within 5 seconds, while the lighting should be fully functional within 60 seconds. Stage 5 Place the luminaires in the important locations in the building b The lifts, the plant rooms, the elevators, the generator rooms and covered parking areas need emergency light powered by batteries to allow people to work during power failure. u 0.5 lux 0.5 m Light in anti-panic areas. 80 ISC00648_01-2008_EN Design (cont.) System types Standard self-contained luminaire system b This kind of system uses luminaires with built-in batteries, charging circuits, and mains sensing, and guarantees an autonomous switching response in an emergency. b Each area can therefore be equipped with one or more luminaires, which guarantee lighting in emergencies thanks to the power reserve contained in their batteries. b The main advantages are ease of installation and connection, plus the fact that even if one luminaire breaks, all the others remain operative, so that the whole safety system is still functionally operative. b Each device is a self-contained luminaire that switches in case of standard mains failure. There is no need for plant rooms or dedicated power lines. It can be installed anywhere, and maintenance is very limited. b Given the way they work, emergency luminaires do not need dedicated lines, being powered by the standard lines. The luminaires are kept charged by the standard lines, and during black-outs they draw the power they need to operate from the charged batteries. b Conversion kits are included with the self-contained luminaires to power fluorescent tubes inside the luminaires for standard lighting during emergencies. P93489 Information concerning emergency lighting system types Typical connection diagram Connection must be made to an uninterrupted supply line taken from the electrical power supply local circuit. If necessary, you can set the system to implement a remote emergency inhibition. Depending to the model, you can use a Teleur remote control if the luminaire has a rest mode setting. P93488 Self-contained luminaire systems b You can carry out some operations when the mains power supply is on using the Teleur remote control, for example synchronising tests or performing immediate manual operation tests. If the mains power supply is off, the Teleur will shut down the emergency luminaires. Connection diagram with emergency inhibition ISC00648_01-2008_EN 81 Technical guide Design (cont.) Emergency light fittings spacing table No! No improvisation on safety! Escape routes Rilux Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37066E 2.5 A Open (Anti-Panic) areas D E F G H (m) 2.72 2.2 6.2 1.9 5.7 3.1 7.8 2.8 7.8 1.89 2.1 6.7 1.8 5.5 3.3 8.2 2.7 7.9 4 1.06 - 5.9 - 4.2 2.5 8.4 2.4 8.0 5 0.68 - - - - 1.8 8.1 1.7 7.9 2.16 1.8 5.4 1.7 4.3 2.7 6.9 2.6 6.8 OVA37067E 2.5 3 1.50 1.5 5.3 1.4 5.2 2.6 7.2 2.5 7.1 4 0.84 - 4.8 - 4.4 2.4 7.4 2.3 7.3 5 0.54 - - - - - 7.0 - 6.9 2.16 1.8 5.4 1.7 4.3 2.7 6.9 2.6 6.8 3 1.50 1.5 5.3 1.4 5.2 2.6 7.2 2.5 7.1 4 0.84 - 4.8 - 4.4 2.4 7.4 2.3 7.3 5 0.54 - - - - - 7.0 - 6.9 7.98 3.5 9.2 3.2 8.4 4.7 11.0 4.5 7.8 OVA37069E 2.5 3 5.54 3.7 9.4 3.6 9.2 4.8 10.9 4.6 7.9 4 3.12 3.6 9.8 3.3 9.6 4.9 9.9 4.7 8.0 5 OVA37070E 2.5 1.99 3.1 10 3.0 9.9 5.0 10 4.9 7.9 11.28 3.8 9.8 3.6 9.7 4.5 11.4 4.4 11.8 3 7.83 3.9 9.9 3.8 9.8 4.8 12.4 4.9 12.1 4 4.41 4.1 10.5 4.0 10.4 5.2 13.0 5.1 12.8 5 OVA37071E 2.5 2.82 4.0 11.2 3.9 11.2 5.3 14.0 5.0 13.8 1.80 1.7 5.2 1.5 5.1 2.7 6.3 2.4 6.5 3 1.25 1.4 5.1 1.3 4.9 2.6 6.5 2.2 6.7 4 0.70 - 4.6 - 4.4 - 6.2 - 6.6 5 0.45 - - - - - 6.0 - 6.2 1.80 1.7 5.2 1.5 5.1 2.7 6.3 2.4 6.5 OVA37072E 2.5 82 C 3 OVA37068E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array 3 1.25 1.4 5.1 1.3 4.9 2.6 6.5 2.2 6.7 4 0.70 - 4.6 - 4.4 - 6.2 - 6.6 5 0.45 - - - - - 6.0 - 6.2 ISC00648_01-2008_EN Escape routes Primalum Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37037E 2.5 A Open (Anti-Panic) areas D E F G H (m) 2.72 2.2 6.2 1.9 5.7 3.1 7.8 2.8 7.8 1.89 2.1 6.7 1.8 5.5 3.3 8.2 2.7 7.9 4 1.06 - 5.9 - 4.2 2.5 8.4 2.4 8.0 5 0.68 - - - - 1.8 8.1 1.7 7.9 2.16 1.8 5.4 1.7 4.3 2.7 6.9 2.6 6.8 OVA37038E 2.5 3 1.50 1.5 5.3 1.4 5.2 2.6 7.2 2.5 7.1 4 0.84 - 4.8 - 4.4 2.4 7.4 2.3 7.3 5 0.54 - - - - - 7.0 - 6.9 7.98 3.5 9.2 3.2 8.4 4.7 11.0 4.5 7.8 7.9 3 5.54 3.7 9.4 3.6 9.2 4.8 10.9 4.6 4 3.12 3.6 9.8 3.3 9.6 4.9 9.9 4.7 8.0 5 1.99 3.1 10.0 3.0 9.9 5.0 10.0 4.9 7.9 11.8 OVA37040E 2.5 ISC00648_01-2008_EN C 3 OVA37039E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array 11.28 3.8 9.8 3.6 9.7 4.5 11.4 4.4 3 7.83 3.9 9.9 3.8 9.8 4.8 12.4 4.9 12.1 4 4.41 4.1 10.5 4.0 10.4 5.2 13.0 5.1 12.8 5 2.82 4.0 11.2 3.9 11.0 5.3 14.0 5.0 13.8 83 Technical guide Design (cont.) Emergency light fittings spacing table (cont.) No! No improvisation on safety! Escape routes Luxa Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37093E 2.5 A E F G H 9.7 (m) 2.8 7.8 2.7 7.6 3.8 9.8 3.7 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 OVA37094E 2.5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 3.09 2.8 7.8 2.7 7.6 3.8 9.8 3.7 9.7 3 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 11.43 4.8 13.1 4.7 12.8 6.4 15.8 6.3 15.7 3 7.93 4.9 13.3 4.8 12.9 6.6 16.3 6.5 16.2 4 4.46 5.1 14.2 5.0 14.1 6.8 19.1 6.7 19.0 5 2.86 5.0 14.4 4.9 14.2 7.1 19.4 7.0 19.2 3.09 2.8 7.8 2.7 7.6 3.8 9.8 3.7 9.7 3 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 OVA37096E 2.5 5 OVA37097E 2.5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 3.09 2.8 7.8 2.7 7.6 3.8 9.8 3.7 9.7 3 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 5 OVA37098E 2.5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 3.09 2.8 7.8 2.7 7.6 3.8 9.8 3.7 9.7 3 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 5 OVA37099E 2.5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 3.09 2.8 7.8 2.7 7.6 3.8 9.8 3.7 9.7 3 2.14 2.6 7.7 2.4 7.5 3.9 10.1 3.8 10.0 4 1.21 1.7 7.4 1.5 7.2 3.8 10.2 3.7 10.1 5 OVA37100E 2.5 0.77 - 6.2 - 6.1 3.0 10.3 2.9 10.0 8.65 4.1 11.8 2.7 7.8 5.6 13.7 3.7 9.8 3 6.0 4.2 11.9 2.8 7.9 5.7 13.8 4.1 10.1 4 3.38 4.0 12.1 2.9 8.2 5.8 13.9 4.2 10.2 5 OVA37101E 2.5 2.16 3.9 12.0 2.8 8.4 6.0 14.2 4.3 10.3 8.65 4.1 11.8 2.7 7.8 5.6 13.7 3.7 9.8 3 6.0 4.2 11.9 2.8 7.9 5.7 13.8 4.1 10.1 4 3.38 4.0 12.1 2.9 8.2 5.8 13.9 4.2 10.2 5 OVA37102E 2.5 2.16 3.9 12.0 2.8 8.4 6.0 14.2 4.3 10.3 11.43 4.8 13.1 4.7 12.8 6.4 15.8 6.3 15.7 3 7.93 4.9 13.3 4.8 12.9 6.6 16.3 6.5 16.2 4 4.46 5.1 14.2 5.0 14.1 6.8 19.1 6.7 19.0 5 2.86 5.0 14.4 4.9 14.2 7.1 19.4 7.0 19.2 1.81 1.8 6.0 1.7 5.9 2.8 8.0 2.7 7.8 3 1.26 1.6 6.8 1.5 6.6 2.6 8.2 2.5 8.0 4 0.71 - 5.9 - 5.4 - 8.1 - 7.9 5 0.45 - - - - - 7.2 - 6.8 5.62 3.7 9.8 2.7 7.6 5.1 14.2 3.7 8.6 OVA37191E 2.5 OVA37192E 2.5 84 D 3.09 OVA37095E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires C 3 5 Open (Anti-Panic) areas B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array 3 3.90 3.5 10.2 2.8 7.7 5.3 14.1 3.8 8.4 4 2.19 3.4 10.6 2.9 7.8 5.6 13.6 3.9 7.5 5 1.40 3.1 10.4 2.6 7.7 5.4 13.8 3.8 7.2 ISC00648_01-2008_EN Escape routes Luxa (cont.) Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37193E 2.5 A Open (Anti-Panic) areas D E F G H (m) 1.81 1.8 6.0 1.7 5.9 2.8 8.0 2.7 7.8 1.26 1.6 6.8 1.5 6.6 2.6 8.2 2.5 8.0 4 0.71 - 5.9 - 5.4 - 8.1 - 7.9 5 0.45 - - - - - 7.2 - 6.8 5.62 3.7 9.8 2.7 7.6 5.1 14.2 3.7 8.6 OVA37194E 2.5 3 3.90 3.5 10.2 2.8 7.7 5.3 14.1 3.8 8.4 4 2.19 3.4 10.6 2.9 7.8 5.6 13.6 3.9 7.5 5 1.40 3.1 10.4 2.6 7.7 5.4 13.8 3.8 7.2 1.81 1.8 6.0 1.7 5.9 2.8 8.0 2.7 7.8 3 1.26 1.6 6.8 1.5 6.6 2.6 8.2 2.5 8.0 4 0.71 - 5.9 - 5.4 - 8.1 - 7.9 5 0.45 - - - - - 7.2 - 6.8 5.62 3.7 9.8 2.7 7.6 5.1 14.2 3.7 8.6 OVA37196E 2.5 3 3.90 3.5 10.2 2.8 7.7 5.3 14.1 3.8 8.4 4 2.19 3.4 10.6 2.9 7.8 5.6 13.6 3.9 7.5 5 OVA37197E 2.5 1.40 3.1 10.4 2.6 7.7 5.4 13.8 3.8 7.2 1.81 1.8 6.0 1.7 5.9 2.8 8.0 2.7 7.8 3 1.26 1.6 6.8 1.5 6.6 2.6 8.2 2.5 8.0 4 0.71 - 5.9 - 5.4 - 8.1 - 7.9 5 0.45 - - - - - 7.2 - 6.8 5.62 3.7 9.8 2.7 7.6 5.1 14.2 3.7 8.6 OVA37198E 2.5 ISC00648_01-2008_EN C 3 OVA37195E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array 3 3.90 3.5 10.2 2.8 7.7 5.3 14.1 3.8 8.4 4 2.19 3.4 10.6 2.9 7.8 5.6 13.6 3.9 7.5 5 1.40 3.1 10.4 2.6 7.7 5.4 13.8 3.8 7.2 85 Technical guide Design (cont.) Emergency light fittings spacing table (cont.) No! No improvisation on safety! Escape routes Domina Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37212E 2.5 A E F G H 7.2 (m) 3.8 9.1 2.2 5.8 4.5 14.0 2.7 2.57 3.7 9.3 2.1 5.9 4.9 15.9 2.8 7.6 4 1.44 3.0 10.2 1.7 6.0 4.8 17.8 3.0 7.9 OVA37213E 2.5 0.92 - 9.8 - 5.7 4.7 20.2 2.8 8.0 3.70 3.8 9.1 2.2 5.8 4.5 14.0 2.7 7.2 3 2.57 3.7 9.3 2.1 5.9 4.9 15.9 2.8 7.6 4 1.44 3.0 10.2 1.7 6.0 4.8 17.8 3.0 7.9 5 0.92 - 9.8 - 5.7 4.7 20.2 2.8 8.0 4.90 4.2 9.6 2.6 6.3 4.8 11.8 2.7 7.9 3 3.40 4.1 10.7 2.5 6.6 5.6 12.5 2.8 8.5 4 1.91 3.8 12.0 2.4 6.8 5.8 14.2 3.0 8.6 5 OVA37215E 2.5 1.23 2.8 11.4 1.8 7.0 5.7 14.8 2.8 8.8 4.62 4.0 9.4 2.4 6.1 4.6 11.6 2.5 7.7 3 3.21 3.9 10.5 2.3 6.4 5.4 12.3 2.7 7.3 4 1.80 3.7 11.8 2.2 6.6 5.6 13.9 2.8 8.3 5 OVA37216E 2.5 1.16 2.6 11.2 1.7 6.8 5.5 14.6 2.6 8.6 5.16 4.7 11.2 2.6 7.4 5.8 14.4 3.9 8.4 3 3.58 4.8 11.8 2.7 7.6 5.9 14.2 3.8 8.6 4 2.02 3.9 12.2 2.8 7.8 6.2 13.8 3.7 8.8 5 1.29 3.0 12.0 2.7 7.9 6.1 6.0 3.8 8.9 18.82 5.4 13.1 4.0 10.3 5.4 14.0 5.5 12.1 3 13.07 6.0 14.2 4.1 11.0 6.5 15.9 5.8 13.8 4 7.35 7.0 15.7 4.2 11.8 7.6 17.8 5.9 14.2 5 4.70 7.3 17.1 4.4 12.1 8.4 20.2 6.0 15.6 7.2 OVA37217E 2.5 OVA37218E 2.5 3.70 3.8 9.1 2.2 5.8 4.5 14.0 2.7 3 2.57 3.7 9.3 2.1 5.9 4.9 15.9 2.8 7.6 4 1.44 3.0 10.2 1.7 6.0 4.8 17.8 3.0 7.9 5 OVA37219E 2.5 0.92 - 9.8 - 5.7 4.7 20.2 2.8 8.0 3.70 3.8 9.1 2.2 5.8 4.5 14.0 2.7 7.2 3 2.57 3.7 9.3 2.1 5.9 4.9 15.9 2.8 7.6 4 1.44 3.0 10.2 1.7 6.0 4.8 17.8 3.0 7.9 5 OVA37220E 2.5 0.92 - 9.8 - 5.7 4.7 20.2 2.8 8.0 4.90 4.2 9.6 2.6 6.3 4.8 11.8 2.7 7.9 3 3.40 4.1 10.7 2.5 6.6 5.6 12.5 2.8 8.5 4 1.91 3.8 12.0 2.4 6.8 5.8 14.2 3.0 8.6 5 OVA37221E 2.5 1.23 2.8 11.4 1.8 7.0 5.7 14.8 2.8 8.8 4.62 4.0 9.4 2.4 6.1 4.6 11.6 2.5 7.7 3 3.21 3.9 10.5 2.3 6.4 5.4 12.3 2.7 7.3 4 1.80 3.7 11.8 2.2 6.6 5.6 13.9 2.8 8.3 5 1.16 2.6 11.2 1.7 6.8 5.5 14.6 2.6 8.6 5.16 4.7 11.2 2.6 7.4 5.8 14.4 3.9 8.4 OVA37222E 2.5 3 3.58 4.8 11.8 2.7 7.6 5.9 14.2 3.8 8.6 4 2.02 3.9 12.2 2.8 7.8 6.2 13.8 3.7 8.8 5 1.29 3.0 12.0 2.7 7.9 6.1 6.0 3.8 8.9 18.82 5.4 13.1 4.0 10.3 5.4 14.0 5.5 12.1 3 13.07 6.0 14.2 4.1 11.0 6.5 15.9 5.8 13.8 4 7.35 7.0 15.7 4.2 11.8 7.6 17.8 5.9 14.2 5 4.70 7.3 17.1 4.4 12.1 8.4 20.2 6.0 15.6 OVA37223E 2.5 86 D 3.70 OVA37214E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires C 3 5 Open (Anti-Panic) areas B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array ISC00648_01-2008_EN Escape routes Domina (cont.) Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) A OVA37224E 2.5 Open (Anti-Panic) areas D E F G H (m) 12.54 4.9 11.2 3.8 8.7 5.6 13.2 11.1 4.3 8.71 5.3 11.9 4.2 9.0 5.9 14.8 11.2 4.8 4 4.9 5.7 13.8 4.8 9.8 6.1 17.4 11.7 4.9 5 3.14 5.9 15.7 4.9 9.9 6.0 18.0 12.3 5.0 12.54 4.9 11.2 3.8 8.7 5.6 13.2 11.1 4.3 3 8.71 5.3 11.9 4.2 9.0 5.9 14.8 11.2 4.8 4 4.9 5.7 13.8 4.8 9.8 6.1 17.4 11.7 4.9 5 3.14 5.9 15.7 4.9 9.9 6.0 18.0 12.3 5.0 OVA37225E 2.5 2.41 3.0 7.8 2.6 5.8 5.8 14.4 2.5 6.1 3 1.67 2.2 7.7 2.1 5.7 5.9 14.2 2.4 6.3 4 0.94 - 7.4 - 5.3 6.2 13.8 2.2 6.6 5 0.60 - 5.8 - 3.1 6.1 6.0 1.9 6.4 2.41 3.0 7.8 2.6 5.8 5.8 14.4 2.5 6.1 OVA37227E 2.5 ISC00648_01-2008_EN C 3 OVA37226E 2.5 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires B Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array 3 1.67 2.2 7.7 2.1 5.7 5.9 14.2 2.4 6.3 4 0.94 - 7.4 - 5.3 6.2 13.8 2.2 6.6 5 0.60 - 5.8 - 3.1 6.1 6.0 1.9 6.4 87 Technical guide Design (cont.) Emergency light fittings spacing table (cont.) Escape routes Rapida Catalog number Installation height for ceiling mounting Lux level Escape routes directly 1 Lux min. under Along centre line luminaires (m) (lux) (m) OVA37576E 2.5 A Open (Anti-Panic) areas B C Open (Anti-Panic) areas 0.5 Lux min. Luminaires arranged in a regular array D E F G H (m) 2.84 2.3 5.7 2.1 5.8 2.5 7.1 2.7 7.6 3 1.98 2.2 5.8 1.8 5.8 2.6 7.2 2.8 7.7 4 1.11 - 6.1 - 5.7 2.7 7.8 2.7 7.8 5 0.71 - 5.8 - 5.2 2.6 8.0 2.1 7.7 8.1 OVA37577E 2.5 4.49 2.2 6.6 2.4 6.9 3.2 8.4 3.4 3 3.12 2.5 6.7 2.5 7.2 3.3 8.5 3.6 8.4 4 1.76 2.1 6.9 2.1 7.5 3.5 8.6 3.7 8.8 5 OVA37578E 2.5 1.12 1.2 6.8 1.2 7.4 3.4 8.7 3.2 8.7 5.24 2.8 7.0 2.8 7.0 3.2 8.6 3.5 9.0 3 3.64 2.9 7.1 2.9 7.3 3.3 8.7 3.7 9.8 4 2.05 2.6 7.2 2.7 7.6 3.5 8.8 3.9 10.4 5 1.31 1.9 7.3 2.2 7.8 3.4 8.9 3.8 11.0 A and E: Transversal spacing to wall B and F: Transversal spacing between luminaires C and G: Axial spacing to wall D and H: Axial spacing between luminaires 88 ISC00648_01-2008_EN Approximate area (in m2) covered by each unit for different ceiling heights to obtain more than 1 lux on the ground. Catalog number Area with 1 Lux min, at the floor level (m2) Installation height for ceiling mounting (m) 2.5 3 4 5 Rilux OVA37066E 8.8 9.2 6.2 0.0 OVA37067E 5.8 6.9 5.3 0.0 OVA37068E 5.8 6.9 5.3 0.0 OVA37069E 19.3 21.6 23.5 24.8 OVA37070E 23.8 24.3 27.3 31.4 OVA37071E 6.6 6.2 5.1 0.0 OVA37072E 6.6 6.2 5.1 0.0 OVA37037E 8.8 9.2 6.2 0.0 OVA37038E 5.8 6.9 5.3 0.0 OVA37039E 19.3 21.6 23.5 24.8 OVA37040E 23.8 24.3 27.3 31.4 OVA37093E 14.8 14.4 13.3 9.5 OVA37094E 14.8 14.4 13.3 9.5 OVA37095E 41.9 42.9 50.1 51.1 OVA37096E 14.8 14.4 13.3 9.5 OVA37097E 14.8 14.4 13.3 9.5 OVA37098E 14.8 14.4 13.3 9.5 OVA37099E 14.8 14.4 13.3 9.5 OVA37100E 23,0 23.5 24.8 25.2 OVA37101E 23.0 23.5 24.8 25.2 OVA37102E 41.9 42.9 50.1 51.1 OVA37191E 8.9 11.2 8.0 0.0 OVA37192E 18.6 19.6 20.7 20.0 OVA37193E 8.9 11.2 8.0 0.0 OVA37194E 18.6 19.6 20.7 20.0 OVA37195E 41.9 42.9 50.1 51.1 OVA37196E 14.8 14.4 13.3 9.5 OVA37197E 8.9 11.2 8.0 0.0 OVA37198E 18.6 19.6 20.7 20.0 Primalum Luxa Domina OVA37212E 11.3 11.0 9.8 4.5 OVA37213E 13.2 13.7 15.3 14.0 OVA37214E 15.1 17.7 20.4 20.0 OVA37215E 14.3 16.8 19.5 19.0 OVA37216E 20.7 22.4 23.8 23.7 OVA37217E 33.7 39.1 46.3 51.7 OVA37218E 11.3 11.0 9.8 4.5 OVA37219E 13.2 13.7 15.3 14.0 OVA37220E 15.1 17.7 20.4 20.0 OVA37221E 14.3 16.8 19.5 19.0 OVA37222E 20.7 22.4 23.8 23.7 OVA37223E 33.7 39.1 46.3 51.7 OVA37224E 24.4 26.8 33.8 38.9 OVA37225E 24.4 26.8 33.8 38.9 OVA37226E 11.3 11.0 9.8 4.5 OVA37227E 11.3 11.0 9.8 4.5 Rapida ISC00648_01-2008_EN OVA37576E 8.3 8.4 8.7 7.5 OVA37577E 11.4 12.1 12.9 12.6 OVA37578E 12.3 13.0 13.7 14.2 89 Design (cont.) Technical guide Connection principle for conversion kits No! No improvisation on safety! Everlux Ferro Single tube, electromagnetic ballast Before (in maintained mode) P94111 Disconnect the wiring Number of Everlux Ferro standard contact Before: internal diagram of the luminaire. After: diagram with Everlux connected. Ballast 5 4 1 After, in maintained mode Switch Switch ~ ~ 230 V 50 Hz Power supply + Teleur - Teleur P94111 P94112 Non-maintained mode a b 5 4 3 2 1 ~ a b Switch Switch. ~ ~ 230 V 50 Hz Power supply + Teleur - Teleur + Out 230 V - 50 Hz Mains 2 3 Ballast 5 4 3 2 1 + Out Teleur ~ 230 V - 50 Hz Recharge line Teleur 230 V - 50 Hz Mains 230 V - 50 Hz Recharge line Double tube, electromagnetic ballast P94114 Before (in maintained mode) Ballast 5 4 1 2 3 230 V - 50 Hz Mains P94114 After, in maintained mode a b Switch Switch + Teleur - Teleur ~ ~ 230 V 50 Hz Power supply 5 4 3 2 1 Ballast (1) + Out Teleur 230 V - 50 Hz Recharge line 230 V - 50 Hz Mains (1) Only one lamp in emergency mode 90 ISC00648_01-2008_EN Everlux Power Single tube, electromagnetic ballast Before (in maintained mode) P94113 Disconnect the wiring Number of Everlux Power standard contact Ballast 5 Before: internal diagram of the luminaire. After: diagram with Everlux connected. 4 7 2 + Teleur - Teleur L N 230/240 V 50/60 Hz 1 230 V - 50 Hz Mains After, in maintained mode 10 9 8 7 6 5 4 3 2 1 P94117 P94113 Non-maintained mode 6 3 8 + Teleur - Teleur L N + - 230/240 V 50/60 Hz 10 9 8 7 6 5 4 3 2 1 Ballast + - Out Out Teleur Teleur 230 V 50 Hz Recharge line 230 V - 50 Hz Mains 230 V 50 Hz Recharge line Double tube, electromagnetic ballast P94116 Before (in maintained mode) Ballast 5 4 (1) 2 3 7 8 6 1 230 V - 50 Hz Mains P94116 After, in maintained mode + Teleur - Teleur L 230/240 V N 50/60 Hz 10 9 8 7 6 5 4 3 2 1 Ballast (1) + Out Teleur 230 V 50 Hz Recharge line 230 V - 50 Hz Mains (1) Only one lamp in emergency mode ISC00648_01-2008_EN 91 Design (cont.) Technical guide Connection principle for conversion kits (cont.) No! No improvisation on safety! Everlux Power Single tube, electronic ballast Before (in maintained mode) 5 P94115 Disconnect the wiring Number of Everlux Power standard contact Before: internal diagram of the luminaire. After: diagram with Everlux connected. 7 4 L N 3 1 2 8 6 Ballast 230 V - 50 Hz Mains After, in maintained mode + Teleur - Teleur L N 230/240 V 50/60 Hz 10 9 8 7 6 5 4 3 2 1 P94115 P94113 Non-maintained mode + Teleur - Teleur L N + - 230/240 V 50/60 Hz Out 10 9 8 7 6 5 4 3 2 1 Teleur L N 230 V 50 Hz Recharge line Ballast + Out Teleur 230 V 50 Hz Recharge line Double tube (6 contacts) , electronic ballast Before (in maintained mode) 5 4 6 1 P94119 L N 3 2 7 Ballast 8 230 V 50 Hz Recharge line P94119 After, in maintained mode + Teleur - Teleur L 230/240 V N 50/60 Hz 10 9 8 7 6 5 4 3 2 1 (1) (1) Only one lamp in emergency mode L N Ballast + Out Teleur 230 V 50 Hz Recharge line 92 ISC00648_01-2008_EN Everlux Power Before (in maintained mode) 5 4 L N P94118 Disconnect the wiring Number of Everlux Power standard contact Double tube (7 contacts), electronic ballast 3 6 Before: internal diagram of the luminaire. After: diagram with Everlux connected. 2 7 1 8 Ballast 230 V - 50 Hz Mains P94118 After, in maintained mode + Teleur - Teleur L 230/240 V N 50/60 Hz 10 9 8 7 6 5 4 3 2 1 (1) + Out L N Teleur Ballast (1) Only one lamp in emergency mode 230 V 50 Hz Recharge line Double tube (8 contacts), electronic ballast Before (in maintained mode) P94120 L N 5 7 4 3 2 1 8 6 Ballast 230 V - 50 Hz Mains P94120 After, in maintained mode + Teleur - Teleur L 230/240 V N 50/60 Hz 10 9 8 7 6 5 4 3 2 1 (1) + Out Teleur L N Ballast 230 V 50 Hz Recharge line ISC00648_01-2008_EN (1) Only one lamp in emergency mode 93 Technical guide Maintenance Periodic checks and maintenance No! No improvisation on safety! It is important to establish preliminary and periodic checking procedures to ensure the system is up to standard and conforms to all technical and regulation requirements, and above all doesn't lose its safety and functional features over time. Checks Once the system is created, the correct tools should be used to ensure that each area complies with the standard levels of ground lighting levels, where necessary. The viewing distance (in metres) and the legibility of the safety signs should be checked for signing the escape route. Periodic maintenance and check records As regards maintenance the most recent rules come from the standard EN 50172 “Emergency escape lighting systems”, which establish a series of procedures to keep the safety lighting system working efficiently. The first thing the standard recommends is to register the periodic checks in a Log Book. This-will contain details of the routine checks, test results, defects and any other changes in the system, as well as any other maintenance operations. The log book should be kept updated and one person should be responsible for keeping it. It-should always be available for inspection by the competent authorities. The log book should contain the following information as a minimum: b Date the system started working including emergency lighting technical. b Documentation concerning the original design and any changes made to it. b Date and brief description of each service inspection or test. b Date and type of periodic check and operation made (month/year written mm/yy). b Date and brief description of any defects found of the corrective measures taken. b Date and brief description of any change of the emergency lighting system. b When an automatic control system is in place the features should be described. Note: if the automatic control system is used, the printed output can replace a data entry in the log book. Other important information to register may be the following: b Information regarding other safety records, for example alarm systems. b Date and type of periodic maintenance or overhaul made. b Serial number or other details of identification of the safety devices. b Name and address of company and other identification details of the maintenance person in charge. b Clear signature of the person in charge of maintenance. A summary of the basic procedures set by the standards to carry out operations safely and keep the system working efficiently on the other hand are: 1. All checking operations of the system, taking special care to check the duration. The-checks should be carried out during low risk periods to allow for any necessary recharging of the batteries, in order to avoid a black-out creating risky situations; 2. Make a daily check of the energy source power supply indicators and each inhibition circuit if present; 3. Each month (preferably each week) carry-out an operational test of the system, simulating failure of the standard power supply for enough time to allow verification of the start-up of the lighting devices and signs. The duration of the test shouldn't significantly limit the autonomy of the devices tested, but should give enough time to check that the devices are present, clean and that they work properly; 4. At least once a year, carry out (or-preferably every six months) a discharge test on each lighting and sign luminaire simulating loss in standard power supply for sufficient time. The type of test should reflect the points noted in paragraph 3 insofar as possible. Note: if an automatic control system is being used, the results of the duration tests must be recorded. 94 ISC00648_01-2008_EN GREEN Luminaire working FLASHING RED 0.5 Hz Luminaire failure 2 Hz Self-containend luminaire systems with selfdiagnosis The luminaires belonging to this series are called Activa, they use technology that allow them to make periodic automatic and autonomous functional and duration checks, thus ensuring greater system reliability and safety. RED Battery faulty or disconnected. The functional tests are carried out automatically every 7 days and the duration tests every 12 weeks. Any defects are indicated by a single multi-coloured LED which shows a pre-determined colour when the system detects a fault. ALTERNATE GREEN and RED Test inhibited Connecting these luminaires is also very easy. They are powered by the mains system and are the same as the STANDARD luminaires. FAST FLASHING RED Connection error If the mains power supply is off, the Teleur can shutdown the emergency luminaire just as it would for the standard luminaires. You can carry out some operations when the mains power supply is on with the Teleur remote control, for example synchronising the tests, inhibiting the checks or carrying out immediate manual functional tests. FLASHING GREEN 0.5 Hz Test in progress A multi-coloured LED displays the status of the luminaire ISC00648_01-2008_EN 95 Technical guide Glossary Emergency lighting glossary No! No improvisation on safety! The majority of these definitions are extracted from the European standards EN 1838 and EN 60598-2-22. Emergency escape lighting That part of emergency lighting that provides illumination for the safety of people leaving a location or attempting to terminate a potentially dangerous process before doing so. Emergency exit A way out that is intended to be used during an emergency. Emergency lighting Lighting provided for use when the supply to the normal lighting fails. Emergency luminaire rated lumen output Lumen output as claimed by the luminaire manufacturer 60 s (0.5 s for high-risk task-area lighting luminaires) after failure of the normal supply, and continuously to the end of rated duration of operation. Emergency mode State of a self-contained emergency luminaire that provides lighting when energized by its internal power source, the normal supply having failed. Escape route A route designated for escape in the event of an emergency. Escape Route Lighting That part of emergency escape lighting provided to ensure that the means of escape can be effectively identified and safety used when the location is occupied. Externally illuminated safety sign A sign that is illuminated, when it is required, by an external source. Internally illuminated safety sign A sign that is illuminated, when it is required, by an internal source. Lumen (lm) Unit of measurement to quantify the amount of light provided by the luminaire (it’s important to specify "the luminaire", because from the nominal value of the light source must be deducted the reduction of light due to the glass cover, the reflector and light source aging). Lux (lm/m ) Unit of measurement to quantify the amount of light provided by the luminaire to a 1 m2 area (for example: 1 lux means 1 lumen measured on a 1 m2 area). 2 Maintained emergency luminaire Luminaire in which the emergency lighting lamps are energized at all times when normal or emergency lighting is required. 96 Maximum overcharge rate Maximum continuous charge rate that may be applied to a fully charged battery. Non-maintained emergency luminaire Luminaire in which the emergency lighting lamps are in operation only when the supply to the normal lighting fails. Normal mode State of a self-contained emergency luminaire that is ready to operate in emergency mode while the normal supply is on. In the case of a normal supply failure, the self-contained luminaire automatically changes over to the emergency mode. Normal supply failure Condition in which the normal lighting can no longer provide a minimum illuminance for emergency escape purposes and when the emergency lighting should become operative. Open Area (or Anti-Panic Area) Lighting That part of emergency escape lighting provided to avoid panic and provide illumination allowing people to reach a place where an escape route can be identified. Rated duration of emergency operation Time, as claimed by the manufacturer, that the rated emergency lumen output is provided. Remote inhibiting facility Means for inhibiting remotely a luminaire associated with an emergency lighting system. Remote inhibiting mode State of a self-contained emergency luminaire which is inhibited from operating by a remote device while the normal supply is on and in case of a normal supply failure the luminaire does not change-over to emergency mode. Rest mode State of a self-contained emergency luminaire that has been intentionally extinguished while the normal supply is off and that, in the event of restoration of the normal supply, automatically reverts to normal mode. Safety sign A sign which gives a general safety message, obtained by a combination of colour and geometric shape and which, by the addition of a graphic symbol of text, gives a particular safety message. Self contained emergency luminaire Luminaire providing maintained or non-maintained emergency lighting in which all the elements, such as the battery, the lamp, where provided, are contained within the luminaire or adjacent to it (i. e., within 1 m cable length). ISC00648_01-2008_EN Numbered parts list Index No! No improvisation on safety! OVA37000 OVA37037E Primalum, non-maintained, 1 h, 65 lm ...................................................................23 OVA37038E Primalum, non-maintained, 1 h,75 lm ....................................................................23 OVA37039E Primalum, non-maintained, 1 h, 160 lm .................................................................23 OVA37040E Primalum, non-maintained, 1 h, 230 lm .................................................................23 OVA37066E Rilux, non-maintained, 1 h, 70 lm ..........................................................................19 OVA37067E Rilux, non-maintained, 1 h, 90 lm ..........................................................................19 OVA37068E Rilux, non-maintained, 3 h, 90 lm ..........................................................................19 OVA37069E Rilux, non-maintained, 1 h, 180 lm ........................................................................19 OVA37070E Rilux, non-maintained, 1 h, 250 lm ........................................................................19 OVA37071E Rilux, maintained, 1 h, 75 lm..................................................................................19 OVA37072E Rilux, maintained, 3 h, 75 lm..................................................................................19 OVA37073E Primalum, non-maintained, 1 h, 110 lm .................................................................23 OVA37093E Luxa, non-maintained IP 42, 1 h, 100 lm................................................................27 OVA37094E Luxa, non-maintained IP 42, 3 h, 90 lm..................................................................27 OVA37095E Luxa, non-maintained IP 42, 1 h, 370 lm................................................................27 OVA37096E Luxa, maintained IP 42, 1 h, 100 lm .......................................................................27 OVA37097E Luxa, maintained IP 42, 3 h, 90 lm .........................................................................27 OVA37098E Luxa, non-maintained IP 65, 1 h, 100 lm................................................................27 OVA37099E Luxa, maintained IP 65, 1 h, 100 lm .......................................................................27 OVA37100E Luxa, non-maintained IP 42, 1 h, 210 lm................................................................27 OVA37101E Luxa, non-maintained IP 65, 1 h, 210 lm................................................................27 OVA37102E Luxa, non-maintained IP 65, 1 h, 370 lm................................................................27 OVA37191E Luxa, non-maintained IP 42, 1 h, 60 lm..................................................................27 OVA37192E Luxa, non-maintained IP 42, 1 h, 180 lm................................................................27 OVA37193E Luxa, non-maintained IP 42, 3 h, 60 lm..................................................................27 OVA37194E Luxa, non-maintained IP 42, 3 h, 115 lm ................................................................27 OVA37195E Luxa, non-maintained IP 65, 1 h, 60 lm..................................................................27 OVA37196E Luxa, non-maintained IP 65, 1 h, 180 lm................................................................27 OVA37197E Luxa, non-maintained IP 65, 3 h, 60 lm..................................................................27 OVA37198E Luxa, non-maintained IP 65, 3 h, 115 lm ................................................................27 OVA37212E Domina, non-maintained IP 42, 1 h, 140 lm ...........................................................33 OVA37213E Domina, non-maintained IP 42, 1 h, 150 lm ...........................................................33 OVA37214E Domina, maintained IP 42, 1 h, 145 lm ..................................................................33 OVA37215E Domina, non-maintained IP 42, 3 h, 85 lm .............................................................33 OVA37216E Domina, non-maintained IP 42, 1 h, 210 lm ...........................................................33 OVA37217E Domina, non-maintained IP 42, 1 h, 640 lm ...........................................................33 OVA37218E Domina, non-maintained IP 65, 1 h, 140 lm ...........................................................33 OVA37219E Domina, non-maintained IP 65, 1 h, 150 lm ...........................................................33 OVA37220E Domina, maintained IP 65, 1 h, 145 lm ..................................................................33 OVA37221E Domina, non-maintained IP 65, 3 h, 85 lm .............................................................33 OVA37222E Domina, non-maintained IP 65, 1 h, 210 lm ...........................................................33 OVA37223E Domina, non-maintained IP 65, 1 h, 640 lm ...........................................................33 OVA37224E Domina, non-maintained IP 42, 1 h, 400 lm ...........................................................33 OVA37225E Domina, non-maintained IP 65, 1 h, 400 lm ...........................................................33 OVA37226E Domina, non-maintained IP 42, 1 h, 100 lm ...........................................................33 OVA37227E Domina, non-maintained IP 65, 1 h, 100 lm ...........................................................33 OVA37576E Rapida, non-maintained IP 42, 1 h, 50 lm ..............................................................39 OVA37577E Rapida, non-maintained IP 42, 1 h, 90 lm ..............................................................39 OVA37578E Rapida, maintained IP 42, 1 h, 100 lm ...................................................................39 OVA38000 OVA38072E Maxi Slim, maintained, 60 m, 1 h ...........................................................................59 OVA38073E Maxi Slim, maintained, 60 m, 3 h ...........................................................................59 OVA38074E Maxi Slim, maintained, 80 m, 1 h ...........................................................................59 OVA38075E Maxi Slim, maintained, 80 m, 3 h ...........................................................................59 OVA38464E Astro Guida, maintained, 24 m, 1 h ........................................................................51 OVA38465E Astro Guida, maintained, 24 m, 3 h ........................................................................51 OVA38466E Astro Guida, maintained, (Activa), 24 m, 1 h ..........................................................51 OVA38504E Quick Signal, maintained, 28 m, 1 h ......................................................................55 OVA38505E Quick Signal, maintained, 28 m, 3 h ......................................................................55 OVA38506E Quick Signal, maintained, (Activa), 28 m, 1 h ........................................................55 OVA41000 OVA41033E Jodiolux, 10 W - 4 h, 1.5 W - 24 h...........................................................................72 OVA41317E Top 4, 6 W - 4 h, 1.5 W - 15 h .................................................................................70 OVA41318E Toplux, 10 W - 1.5 h, 1.5 W - 15 h ..........................................................................71 OVA41319E Toplux, 10 W - 4 h, 1.5 W - 24 h .............................................................................71 OVA41435E Guardian, non-maintained, 1 h 400 lm...................................................................45 OVA41436E Guardian, non-maintained, 1 h 1050 lm.................................................................45 OVA41437E Guardian, non-maintained, 1 h 200 lm...................................................................45 OVA43100 OVA43101E Everlux Ferro, 5 VA, 3.6 V, 2 Ah, batteries side by side ..........................................63 OVA43102E Everlux Ferro, 5 VA, 3.6 V, 2 Ah, batteries in line ...................................................63 OVA43103E Everlux Ferro, 5 VA, 3.6 V, 4 Ah, batteries side by side ..........................................63 OVA43104E Everlux Ferro, 5 VA, 3.6 V, 4 Ah, batteries in line ...................................................63 OVA43105E Everlux Ferro, 4.5 VA, 3.6 V, 2 Ah, batteries in line ................................................63 OVA43106E Everlux Ferro, 7 VA, 3.6 V, 4 Ah, batteries in line ...................................................63 OVA43107E Everlux Power, 5.5 VA, 3.6 V, Ah...........................................................................65 OVA43108E Everlux Power, 6 VA, 4.8 V, Ah..............................................................................65 OVA43109E Everlux Power, 6.5 VA, 6.0 V, Ah...........................................................................65 ISC00648_01-2008_EN 97 Index Numbered parts list (cont.) OVA50200 OVA50236E Set of 10 pictograms for Rilux 6 W (running man towards the right) .......................19 OVA50237E Set of 10 pictograms for Rilux 6 W (exit) ................................................................19 OVA50238E Set of 10 pictograms for Rilux 8 W (running man towards the right) .......................19 OVA50239E Set of 10 pictograms for Rilux 8 W (exit) ................................................................19 OVA50240E Set of 10 pictograms for Rilux 11/18 W (running man towards the right) ................19 OVA50241E Set of 10 pictograms for Rilux 11/18 W (exit) .........................................................19 OVA50242E Set of 10 pictograms for Luxa 6/11 W (running man towards the right) ..................28 OVA50243E Set of 10 pictograms for Luxa 6/11 W (exit) ...........................................................28 OVA50244E Set of 10 pictograms for Luxa 8 W (running man towards the right) .......................28 OVA50245E Set of 10 pictograms for Luxa 8 W (exit) ................................................................28 OVA50246E Set of 5 pictogram stickers for Astro Guida (spare part) .........................................51 OVA50247E Set of 10 pictograms for Rilux 6 W (running man towards the left) .........................19 OVA50248E Set of 10 pictograms for Rilux 6 W (running man downward).................................19 OVA50249E Set of 10 pictograms for Rilux 8 W (running man towards the left) .........................19 OVA50250E Set of 10 pictograms for Rilux 8 W (running man downward).................................19 OVA50251E Set of 10 pictograms for Rilux 11/18 W (running man towards the left) ..................19 OVA50252E Set of 10 pictograms for Rilux 11/18 W (running man downward) ..........................19 OVA50253E Set of 10 pictograms for Luxa 6/11 W (running man towards the left) ....................28 OVA50254E Set of 10 pictograms for Luxa 6/11 W (running man downward) ............................28 OVA50255E Set of 10 pictograms for Luxa 8 W (running man towards the left) .........................28 OVA50256E Set of 10 pictograms for Luxa 8 W (running man downward) .................................28 OVA50257E Set of 10 pictograms for Rapida 6 W (running man towards the right) ...................40 OVA50258E Set of 10 pictograms for Rapida 6 W (running man towards the left)......................40 OVA50259E Set of 10 pictograms for Rapida 6 W (running man downward) .............................40 OVA50260E Set of 10 pictograms for Rapida 6 W (exit in EN) ...................................................40 OVA50261E Set of 10 pictograms for Rapida 6 W (exit in ES) ...................................................40 OVA50262E Set of 10 pictograms for Rapida 8 W (running man towards the right) ...................40 OVA50263E Set of 10 pictograms for Rapida 8 W (running man towards the left)......................40 OVA50264E Set of 10 pictograms for Rapida 8 W (running man downward) .............................40 OVA50265E Set of 10 pictograms for Rapida 8 W (exit in EN) ...................................................40 OVA50266E Set of 10 pictograms for Rapida 8 W (exit in ES) ...................................................40 OVA50267E Set of 10 pictograms for Domina 6/11 W (running man towards the right)..............34 OVA50268E Set of 10 pictograms for Domina 6/11 W (running man towards the left) ................34 OVA50269E Set of 10 pictograms for Domina 6/11 W (running man downward) .......................34 OVA50270E Set of 10 pictograms for Domina 6/11 W (exit in EN) .............................................34 OVA50271E Set of 10 pictograms for Domina 6/11 W (exit in ES)..............................................34 OVA50272E Set of 10 pictograms for Domina 8/24 W (running man towards the right) .............34 OVA50273E Set of 10 pictograms for Domina 8/24 W (running man towards the left)................34 OVA50274E Set of 10 pictograms for Domina 8/24 W (running man downward) .......................34 OVA50275E Set of 10 pictograms for Domina 8/24 W (exit in EN) .............................................34 OVA50276E Set of 10 pictograms for Domina 8/24 W (exit in ES) .............................................34 OVA50277E Set of 4 pictograms for Domina exit signs kit .........................................................35 OVA50278E Set of 4 pictograms for Rapida exit signs kit OVA53018 ........................................41 OVA50279E Set of 10 pictograms for Luxa 6/11 W (exit in ES) ..................................................28 OVA50280E Set of 10 pictograms for Luxa 8 W (exit in ES) .......................................................28 OVA50281E Exit sign screens for Astro Guida (exit in EN) 1 or 2 sides ......................................51 OVA50282E Exit sign screens for Astro Guida (exit in ES) 1 or 2 sides ......................................51 OVA50283E Set of 4 pictograms for Luxa exit signs kit ..............................................................29 OVA50284E Set of 10 pictograms for Primalum 6/11 W (running man towards the right) ...........23 OVA50285E Set of 10 pictograms for Primalum 6/11 W (running man towards the left) .............23 OVA50286E Set of 10 pictograms for Primalum 6/11 W (running man downward).....................23 OVA50287E Set of 10 pictograms for Primalum 6/11 W (exit in EN) ...........................................23 OVA50288E Set of 10 pictograms for Primalum 6/11 W (exit in ES) ...........................................23 OVA50289E Set of 10 pictograms for Primalum 8/18 W (running man towards the right)...........23 OVA50290E Set of 10 pictograms for Primalum 8/18 W (running man towards the left) .............23 OVA50291E Set of 10 pictograms for Primalum 8/18 W (running man downward) ....................23 OVA50292E Set of 10 pictograms for Primalum 8/18 W (exit in EN) ..........................................23 OVA50293E Set of 10 pictograms for Primalum 8/18 W (exit in ES)...........................................23 OVA50300 OVA50314E Hanging kit for Quik Signal ....................................................................................55 OVA50315E Diffuser signaller for Top 4 or Toplux ................................................................ 70, 71 OVA50316E Wall / flag type bracket for Quik Signal (spare part) ...............................................55 OVA50318E False ceiling mounting kit for Quik Signal ..............................................................55 OVA50319E Exit sign screen for Quick Signal (running man towards the right), 1 side ..............55 OVA50320E Exit sign screen for Quick Signal (running man towards the left), 1 side ................55 OVA50321E Exit sign screen for Quick Signal (running man downward), 1 side ........................55 OVA50322E Exit sign screens for Quick Signal (running man), 2 sides .....................................55 OVA50323E Exit sign screens for Quick Signal (running man downward), 2 sides ....................55 OVA50324E Exit sign screens for Quick Signal (exit in EN) 1 or 2 sides ....................................55 OVA50325E Teleur ....................................................................................................................73 OVA50326E Teleur 500 .............................................................................................................73 OVA50328E Ceiling mounting exit sign for Luxa 8 W .................................................................28 OVA50329E Flag mounting exit sign for Luxa 8 W .....................................................................28 OVA50330E Wall mounting exit sign for Luxa 8 W .....................................................................28 OVA50342E Protective grid (2 parts) for Guardian.....................................................................45 OVA50343E Protective grid for Rilux, Primalum, Luxa or Rapida (6/11/18 W) ......... 19, 23, 28, 40 OVA50344E Protective grid for Rilux, Primalum, Luxa or Rapida (8 W) ................... 19, 23, 28, 40 OVA50345E Flush mounting box for Luxa 6/11 W......................................................................28 OVA50346E Flush mounting box for Luxa 8 W ..........................................................................28 OVA50347E Hanging / electrified track kit for Primalum, Luxa or Domina ...................... 23, 28, 34 OVA50348E False ceiling kit for Luxa ........................................................................................28 OVA50349E White frame for Luxa 6/11 W .................................................................................28 OVA50350E Grey frame for Luxa 6/11 W ...................................................................................28 OVA50351E Black frame for Luxa 6/11 W ..................................................................................28 98 ISC00648_01-2008_EN OVA50352E White frame for Luxa 8 W ......................................................................................28 OVA50353E Grey frame for Luxa 8 W........................................................................................28 OVA50354E Black frame for Luxa 8 W.......................................................................................28 OVA50355E Flag bracket (spare part) for Astro Guida ...............................................................51 OVA50356E Ceiling, hanging and electrified track kit fot Astro Guida ........................................51 OVA50357E Protective grid for Astro Guida ...............................................................................51 OVA50358E Charger for Top 4, Toplux or Jodiolux......................................................... 70, 71, 72 OVA50359E Lamp support for Jodiolux .....................................................................................72 OVA50360E Lamp support for Top 4 or Toplux ..................................................................... 70, 71 OVA51000 OVA51000E Lamp, 6 V, 1.5 W for Top 4, Toplux or Jodiolux ........................................... 70, 71, 72 OVA51001E Lamp, xenon, 6 V, 0.9 A, E10 for Top 4 ..................................................................70 OVA51002E Lamp, halogen 6 V, 1.5 W for Guardian, Toplux or Jodiolux ....................... 45, 71, 72 OVA51003E Lamps, 20 W for Guardian.....................................................................................45 OVA51004E Lamps, 50 W for Guardian.....................................................................................45 OVA51005E Fluorescent tube, 6 W G5 for Rilux, Primalum or Luxa .............................. 19, 23, 29 OVA51006E Fluorescent tube, 8 W G5 for Rilux, Primalum or Luxa .............................. 19, 23, 29 OVA51007E Fluorescent tube, 8 W G5 for Rilux, Luxa, Domina or Rapida .............. 19, 29, 35, 41 OVA51008E Fluorescent tube, 8 W G5 for Luxa ........................................................................29 OVA51009E Fluorescent tube, U11 W 2G7 for Rilux, Primalum or Domina ................... 19, 23, 35 OVA51010E Fluorescent tube, 11 W 2G7 for Luxa ....................................................................29 OVA51011E Fluorescent tube, U18 W 2G11 for Rilux or Primalum ...................................... 19, 23 OVA51012E Battery, Ni-Cd, 2.4 V, 1.5 Ah for Rilux, Primalum, Luxa or Rapida ........ 19, 23, 29, 41 OVA51013E Battery, Ni-Cd, 3.6 V, 1.5 Ah for Luxa or Rapida............................................... 29, 41 OVA51014E Battery, Ni-Cd, 4.8 V, 0.6 Ah for Quik Signal ..........................................................55 OVA51015E Battery, Ni-Cd, 4.8 V, 1.5 Ah for Quik Signal ..........................................................55 OVA51016E Battery, Ni-Cd, 4.8 V, 1.5 Ah for Rilux, Primalum, Luxa or Domina ....... 19, 23, 29, 35 OVA51017E Battery, Ni-Cd, 4.8 V, 2.2 Ah for Luxa .....................................................................29 OVA51018E Battery, Ni-Cd, 6 V, 0.6 Ah for Rilux........................................................................19 OVA51019E Battery, Ni-Cd, 6 V, 1.5 Ah for Rilux, Domina or Maxi Slim M60 ................. 19, 35, 59 OVA51020E Battery, Ni-Cd, 6 V, 7 Ah for Jodiolux .....................................................................72 OVA51021E Battery, Ni-Cd, 7.2 V, 1.5 Ah for Rilux, Primalum or Luxa ........................... 19, 23, 29 OVA51022E Battery, Ni-Cd, 8.4 V, 1.5 Ah for Luxa .....................................................................29 OVA51023E Battery, Pb, 6 V, 4, Ah for Top 4 or Toplux ......................................................... 70, 71 OVA51024E Battery, Pb, 12 V, 7.2 V for Guardian .....................................................................45 OVA51025E Battery, Pb, 6 V, 7.2 Ah for Guardian......................................................................45 OVA51026E Batteries, Ni-Cd, 3.6 V, 2 Ah, in line for Everlux Ferro ............................................63 OVA51027E Batteries, Ni-Cd, 3.6 V, 2 Ah, side by side for Everlux Ferro ...................................63 OVA51028E Batteries, Ni-Cd, 3.6 V, 4 Ah, in line for Everlux Ferro ............................................63 OVA51029E Batteries, Ni-Cd, 3.6 V, 4 Ah, side by side for Everlux Ferro ...................................63 OVA51030E Batteries, Ni-Cd, 3.6 V, 4.0 Ah for Everlux Power...................................................65 OVA51031E Batteries, Ni-Cd, 4.8 V, 4.0 Ah for Everlux Power...................................................65 OVA51032E Batteries, Ni-Cd, 6.0 V, 4.0 Ah for Everlux Power...................................................65 OVA51033E LED for Everlux Ferro or Everlux Power .......................................................... 63, 65 OVA51034E Fluorescent tube for Maxi Slim M60 ......................................................................59 OVA51035E Fluorescent tube for Maxi Slim M80 ......................................................................59 OVA51036E Battery, Ni-Cd, 6 V, 7 Ah for Toplux ........................................................................71 OVA51037E Fluorescent tube, 6 W G5 for Luxa, Domina or Rapida .............................. 29, 35, 41 OVA51038E Battery, Ni-Cd, 6 V, 2.2 Ah for Luxa ........................................................................29 OVA51039E Battery, Ni-Cd, 6 V, 4.0 Ah for Domina or Maxi Slim M80 ................................. 35, 59 OVA51040E Battery, Ni-Cd, 9.6 V, 1.5 Ah for Domina ................................................................35 OVA51041E Fluorescent tube, 8 W G5 for Domina....................................................................35 OVA51042E Fluorescent tube, 24 W 2G11 for Domina ..............................................................35 OVA51043E Fluorescent tube, 8 W G5 for Luxa or Rapida .................................................. 29, 41 OVA51044E Fluorescent tube, 11 W 2G7 for Luxa ....................................................................29 ISC00648_01-2008_EN 99 Index Numbered parts list (cont.) OVA53000 OVA53000E Exit sign screen for Maxi Slim M60 (running man towards right) 1 side..................59 OVA53001E Exit sign screen for Maxi Slim M60 (running man towards left) 1 side ....................59 OVA53002E Exit sign screen for Maxi Slim M60 (running man downward) 1 side......................59 OVA53003E Exit sign screens for Maxi Slim M60 (running man) 2 sides ...................................59 OVA53004E Exit sign screens for Maxi Slim M60 (running man downward) 2 sides ..................59 OVA53005E Exit sign screen for Maxi Slim M80 (running man towards right) 1 side..................59 OVA53006E Exit sign screen for Maxi Slim M80 (running man towards left) 1 side ....................59 OVA53007E Exit sign screen for Maxi Slim M80 (running man downward) 1 side......................59 OVA53008E Exit sign screens for Maxi Slim M80 (running man) 2 sides ...................................59 OVA53009E Exit sign screens for Maxi Slim M80 (running man downward) 2 sides ..................59 OVA53010E Protective grid for Maxi Slim M60 ..........................................................................59 OVA53011E Protective grid for Maxi Slim M80 ..........................................................................59 OVA53012E Protective grid for flush mounting Rapida 6 W .......................................................40 OVA53013E Protective grid for flush mounting Rapida 8 W .......................................................40 OVA53014E Flush mounting an false ceiling kit for Rapida 6 W .................................................40 OVA53015E Flush mounting an false ceiling kit for Rapida 8 W .................................................40 OVA53016E Exit signs kit visibility 30 m for Rapida 6 W (running man left and right) ................40 OVA53017E Exit signs kit visibility 30 m for Rapida 6 W (running man towards downward) .......40 OVA53018E Exit signs kit visibility 23 m for Rapida 8 W (running man left and right and down) .40 OVA53019E Protective grid for Domina 6/11 W .........................................................................34 OVA53020E Protective grid for Domina 8/24 W .........................................................................34 OVA53021E Flush mounting box for Domina 6/11 W .................................................................34 OVA53022E Flush mounting box for Domina 8/24 W .................................................................34 OVA53023E False ceiling kit for Primalum or Domina.......................................................... 23, 34 OVA53024E Exit signs kit, ceiling mounting for Domina.............................................................34 OVA53025E Exit signs kit, flag mounting for Domina .................................................................34 OVA53026E Exit signs kit, wall mounting for Domina.................................................................34 OVA53027E Flag type bracket for Rapida exit signs kit..............................................................40 OVA53028E White frame for Primalum 6/11 W ..........................................................................23 OVA53029E Grey frame for Primalum 6/11 W ...........................................................................23 OVA53030E White frame for Primalum 8/18 W ..........................................................................23 OVA53031E Grey frame for Primalum 8/18 W ...........................................................................23 OVA53032E Exit sign screens for Quick Signal (exit in ES) 1 or 2 sides.....................................55 OVA53033E Flush mounting box for Primalum 6/11 W ..............................................................23 OVA53034E Flush mounting box for Primalum 8/18 W ..............................................................23 OVA53036E Aluminium frame for Luxa 6/11 W ..........................................................................28 OVA53037E Aluminium frame for Luxa 8 W ...............................................................................28 100 ISC00648_01-2008_EN No improvisation on safety! ART.XXXX © Schneider Electric - All rights reserved Schneider Electric Industries SAS 89, boulevard Franklin Roosevelt F-92505 Rueil-Malmaison Cedex Tel: +33 (0)1 41 29 85 00 www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Publishing: Schneider Electric Industries SAS Design: Printing: ISC00648 01-2008