POWER PRODUCT Panelboards Contents 6-2 – 6-7 6-8 6-9 – 6-10 6-11 – 6-12 6-13 6-14 – 6-16 6-17 – 6-18 6-19 6-20 6-21 6-22 6-23 – 6-24 6-25 6-26 6-27 – 6-30 6-31 6-32 6-33 6-34 6-35 – 6-36 6-37 6-42 6-42 6-44 6-45 6-46 PANELBOARDS 6-38 6-39 6-39 6-40 6-41 6 Features, Reference Guide & General Specifications Factory Assembled Panelboard Coding System Type P1 Specifications Unassembled panelboard Main Lug and Main Breaker Branch and Subfeed Breakers Modifications and Additions S1/S2 Replacement parts Enclosure Dimensions Type P2 Specifications Enclosure Selection / Dimensions Unassembled panelboard Main Breaker and Subfeed Breakers Branch Breakers Modifications and Additions Enclosure Dimensions Type P3 Specifications Enclosure Selection / Dimensions Branch Breakers Modifications and Additions Enclosure Dimensions Type S5 Specifications Main Lug and Main Breaker Selection Branch Breakers Modifications and Additions Modifications, Additions, Replacements for Circuit Breakers Type F2 Specifications and Fuse Types Main Lug and Main Fusible Modifications and Additions Modifications, Additions, Replacements for Fusible Switches Panel Skirt/System Types, AC & DC Voltages Panelboards Introduction General This generation of panelboards from Siemens offers the high level of engineering and innovation you’ve come to expect from the leader in power distribution technology. The “P Series” line of panelboards, complimented by the S5 power panels and F2 switchboards, offers a stepped approach to power distribution. Additional strength has been added to an already rugged and durable panelboard family. Engineered specifically to provide maximum flexibility, the new designs simplify wiring and reduce material requirements making them easier to install and less costly than competitive products. At the heart of these product lines is the extensive research and technology found among Siemens circuit protection devices – both fusible switches and molded case circuit breakers. The line is anchored by the innovative P1. Featuring the industry’s most flexible designs, the P1 virtually eliminates common errors, such as feed direction, and main lug versus main breaker. Increasing distribution is simplified by the ability to add feed-thru lugs. Because of its unique design, the P1 meets the majority of lighting panel needs with only six standard sizes. Subsequent steps in the P Series offer increased capacity and more design options: b The highly flexible P2 provides options to fit the most demanding specifications. b Sized more like a lighting panel, the P3 packs the power of a distribution panel in a space-saving design. b The powerful S5 is a distribution panel that allows circuit breakers as branch and main devices. b The F2 anchors the high end of the series. With larger fusible and circuit breaker branch and main devices, the venerable F2 delivers maximum power and flexibility to larger distribution systems. Features Overview P Series lighting panel features include Fas-Latch trim, which is popular among installers; the jacking screw system, that permits adjustments even after wiring has been installed; our exclusive split neutral, and more. Many panelboards have the capability of mixing and matching breakers of different sizes and ratings – or changing from main lug to main breaker, or adding subfeed breakers without changing the box size. Key Panelboard Features P1 P2 P3 S5 • • • • • — • • • • Convertible from Top Feed to Bottom Feed or Vice Versa • — — — — Change from Main Lug to Main Breaker or add Subfeed without changing enclosure size • — — — — Lighting and Appliance Applications PANELBOARDS 6 Power Panelboard Applications Space-Saving, Horizontally Mounted Main Breaker F2 Up To 250 Amps Up To 250 Amps — • • Short-Circuit Rating Label Giving Performance Level • • • • • Standard Aluminum Ground Assembly • • • • • Blank End-Walls Standard Bolted Current-Carrying Parts • • • • • • • • • • Split Neutral • • • • • Connection Accessible from Front • • • • • Screw-Type Mechanical Lugs • • • • • Time-Reducing Wing Nuts to Secure Interior Without Tools • • • • • Main and Branch Devices Connected With Case-Hardened Hardware • • • • • Flush Lock, Concealed Door Hinges/Trim Screws • • • — — Symmetrical Interior Mounting Studs To Eliminate Upside-Down Mounting of Box • • • • • Interior Height Adjustment for Flush Applications • • • — — Mix and Match Fusible Switch Circuit Breaker Capability Shallow Depth — — — — — 5.75" 5.75" 7.75" 12.75" 12.75" Accepts a Wide Range of Fuse Types — — — — • Accepts Vacu-Break Fusible Switch — — — — • Accepts a Wide Range of Circuit Breakers — • • • — • • • • • Optional Compression Lugs • Standard KO’s available on P1 and P2 – 5.75" Deep x 20" Wide boxes and P3 - 7.75" deep x 24" wide boxes. 6-2 Siemens Canada Limited Power Product Catalogue Panelboards General Specifications Service Entrance Equipment When a panelboard is used as service entrance equipment, it must be located as close as practicable to the point of entrance of building supply conductors. Panelboards must be identified as "Service Entrance" at the time of order entry in order to be supplied with the appropriate CSA certification and labelling. Panels must include a connector for bonding and grounding neutral conductor. Please consult CSA, CEC and local inspection authorities for specification and installation guidelines. Integrated Equipment Short Circuit Rating The term “Integrated Equipment Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by CSA. "Series Rated" must be identified at the time of order entry. Standards CSA: C22.2 No.29. Certified under files # 93833 UL: 67 and 50. Listed by Underwriter’s Laboratories, Inc., under “Panelboards” File #E2269, and #E4016. Lug Data Feed-Thru Lugs Fig. G-1 Subfeed Lugs or Double Lug Fig. G-2 Feed-thru lugs are mounted at the opposite end of the main bus from the main lugs or main breaker and are used to connect two or more panelboards to the incoming feeder. The feeder cables are brought into Panelboard 1 and connected to the main lugs or main breaker. Cables interconnecting the two panelboards are connected to the feed-thru lugs in Panelboard1 and are carried over the main lugs in Panelboard 2. This arrangement could be reversed with the main lugs located at the top and the feed-thru lugs at the bottom of the panel. Subfeed lugs are mounted directly beside the main incoming lugs and are used to connect two or more panelboards to the incoming feeder. The feeder cables are brought into Panelboard 1 and connected to the main lugs. Another set of cables that are the same size are connected to the subfeed lugs of Panelboard 1 and are carried over the main lugs of Panelboard 2. 6 PANELBOARDS Wire Connectors Standard wire connectors in Siemens panels are suitable for copper or aluminum cables rated 60/75 degree. Copper main lugs are a price-added option for most panel types and some Circuit Breakers (check with Siemens sales for availability). It should be noted that most copper lugs will only accept copper cables. Some applications, 100% rated devices in particular, require that the cable and connectors be rated 90 degree but are sized to the 75 degree tables. General Standard ground connectors are also suitable for copper or aluminum wire. Ground connector assemblies (EGK, IGK) have (7) 1/0 max. and (15) #6 max. connections. The 1/0 holes are capable of connecting up (3) #10 max. wires. Copper ground assemblies (ECGK, ICGK) are rated for copper wire only and have the same wiring capacity as the Al/Cu connectors. Standard neutrals, like standard main lugs, are also rated for copper or aluminum wire. The neutral cross bar material follows the selection bus. Copper neutral lugs are rated for copper cable only and available as a price added option. Siemens Canada Limited Power Product Catalogue 6-3 Panelboards General Specifications General Bussing Sequence All breakers have bolted connections. The panel design provides bracing up to 200,000A IR CSA short circuit rating. Interiors are designed to accommodate top or bottom feed. Circuit Breaker Lighting Panel Type P1 Circuit Breaker Lighting or Distribution Panel Types P2/P3 Case-hardened, high performance, thread rolling screws are used on branch bus. Circuit Breaker Distribution Panel Type S5 Fusible Switch Distribution Panel Type F2 Panelboard Ratings P1 P2 P3 S5 F2 Max. Voltage 600V AC Max. 250V DC Max 600V AC Max. 250V DC Max. 600V AC Max. 250V DC Max. 600V AC Max. 250V DC Max. 600V AC Max. 250V DC Max. System 1-Phase, 1-Phase, 3-Phase, 3-Phase, 1-Phase, 1-Phase, 3-Phase, 3-Phase, 1-Phase, 1-Phase, 3-Phase, 3-Phase, 1-Phase, 3-wire 3-Phase, 4-wire 3-Phase, 3-wire 1-Phase, 3-wire 3-Phase, 4-wire 3-Phase, 3-wire 6 Description 2-wire 3-wire 3-wire 4-wire 2-wire 3-wire 3-wire 4-wire 2-wire 3-wire 4-wire 3-wire PANELBOARDS Mains Main Lugs Main Breaker Main Switch 125A-400A 100A-400A — 125A-600A 100A-600A — 400A-800A — — 400A-1200A 400A-1200A — 800A-1200A — 200A-600A Circuits 18, 30, 42 18, 30, 42, 54, 66 78, 90, 102, 114 42, 54, 66, 78, 90 — — Branch Ratings 15-100A 15-400A 15-125A 15-1200A MCCB 30A-600A Fusible Branch Disconnect Devices BL, BLH, HBL, BQD, BQD6, BLE, BLEH, BLF, BLHF, BAF, BAFH BL, BLH, HBL, BQD, BQD6, QJ2, QJH2, QJ2H, HQJ2H, ED2, ED4, ED6, HED4, BLE, BLEH, BLF, BLHF, BAF, BAFH, BGL, NGB BL, BLH, HBL, BQD, BQD6, ED2, ED4, HED4, ED6, BLHF, BAF, BAFH, BGL, NGB, NEB, HEB All 15-1200A MCCBs and 30-200A VB switches 30-600A VK/VB switches Subfeed Circuit Breakers ED2, ED4, ED6, HED4, QJ2, QJH2, QJ2-H, FD6, HFD6, FXD6 FD6, HFD6, FXD6, HFXD6 — — — Enclosure Heights - inches (mm) 32, 38, 44 @250 A (813, 965, 1118) 56, 62, 68 @400 A (1422, 1575, 1727) 26, 32, 38, 44, 50, 56, 62, 68, 74 (660-1880) 56, 62, 68, 74, 80 (1422-2032) 60, 75, 90 (1524, 1905, 2286) 60, 75, 90 (1524, 1905, 2286) Standard Trims Fas-Latch – 1 Piece Surface or Flush Fas-Latch – 1 Piece Surface or Flush Fas-Latch – 1 Piece Surface or Flush — — P1 can have 1 subfeed breaker. P2 can have up to (2) FD subfeed breakers. JD and FD breakers are mounted vertical. Limitations apply. 6-4 Trim ring provided for flush applications. A maximum of (4) QJ breakers may be mounted in a P2 Panel and are single mounted. Siemens Canada Limited Power Product Catalogue Panelboards General Specifications General Typical Panelboard Modifications Description Lighting and Distribution Panelboards P1 P2 P3 • • • • • • • • • • Box Type 3R/12 Type 4/4X Drip Proof Hood Gasketed Trim Wider Box Deeper Box — • • • • • • Front Hinged Front Door-in-Door Front Nameplate Door with Padlock • • • • • • • • Standard Standard Interior Aluminum Equipment Ground Bar Copper Equipment Ground Bar Insulated Equipment Ground Subfeed Lugs Feed-Thru Lugs Compression Lugs Copper Lugs — • • • • • • • • • • • • • • • • • • • • • — — — Standard Standard Standard Check Plant For Availability Standard • • • • • • • • • • • Tin plated Aluminum Tin plated Copper Silver plated Copper Copper Plating - Tin or Silver Standard Standard Standard Check Plant For Availability Standard — Tin Std./ Silver Optional Tin Std./ Silver Optional Tin Std./ Silver Optional Silver Std./ Tin Optional Silver Std./ Tin Optional Circuit Breaker Shunt Trips R, J and T Fuse Clips • • • • — — — — • • 200% Neutral • • Power and Distribution Panelboards S5 F2 — • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Available as an option. 6 PANELBOARDS Siemens Canada Limited Power Product Catalogue 6-5 Panelboards Options Standard Trim (FAS-Latch) PANELBOARDS 6 Trim Also available: b Screw to Box Trim b Piano Hinge Trim b Trim with Padlock Door in Door Front Hinged Front 6-6 Siemens Canada Limited Power Product Catalogue Panelboards Special Enclosures Options 6 Type 4/4X Enclosure PANELBOARDS Type 3R and 3R/12 Enclosure Panel Family Portrait Panelboard Family for Lighting and Appliance and Distribution Panel Applications Siemens Canada Limited Power Product Catalogue 6-7 Panelboards Factory Assembled Selection Panelboard Coding System Type of Panel P1, P2, P3, S5, F2 Voltage and System* C = 208Y/120 3Ø 4 W Wye AC - All E = 480Y/277 3Ø 4 W Wye AC - All D = 240 3Ø 3 W Delta AC - All A = 120/240 1Ø 3 W Grounded Neutral AC (2) - All L = 600/347 3Ø 4 W Wye AC - All N = 125V DC 2-Pole Branches Only - All O = 125/250V DC 2-Pole Branches Only - All P = 125/250V DC 2 & 3-Pole Branches - All *For any voltage system not listed, check with sales for availability. Circuits or P1 – 18, 30, 42 P2 – 18, 30, 42, 54, 66, 78, 90, 102 , 114 P3 – 42, 54, 66, 78, 90 Enclosure Height S5, F2 – 60, 75, 90 Main Lug (ML), Main Breaker (See Main Breaker Table coding below) Amperage 100–400A = P1 400– 800A = P3 100–600A = P2 400 –1200A = S5, F2 Bus Plating Tin-Plated Tin-Plated Silver-Plated PANELBOARDS 6 Bus Material Aluminum Copper Copper Letter A C E Bus Code P1 P2 P3 S5 F2 A C E • • optional • • optional • • optional • n/a • • n/a • • Indicates default for this bus type. Feed Location T = Top B = Bottom Mounting S = Surface F = Flush. Flush trims extend 3/4" beyond each side of the base box dimensions on P1, P2 and P3 and extend 1” beyond each side of the base box dimensions on. Main Breaker Coding (Breaker Type) Code (BAF) BA, (BAFH) BF, (BQD) BQ, (BQD6) B6, (BL) BL, (BLEH) BE, (BLH) BH, (BLR) BR, (HBL) HB, (BGL-SWI) B1, (BLE-GFCI) BG, (BLF-GFCI) BC, (CED6) CE, (ED2) ED, (ED4) E4, (ED6) E6, (HED4) H4, (BLHF-GFCI) B4, (NGB) NB, (QJ2) QJ, (QJ2H) Q2, (QJH2) QH, (Q3) HQJ2H, (CFD6) CF, (FD6) FD, (FXD6) FX, (HFD6) HF, (HFXD6) H2, (HHFD6) H1, (HHFXD6) H3, (CJD6) CJ, (HHJD6) H4, (HHJXD6) H9, (HJD6) H6, (HJXD6) H5, (HJXD6H) H7, (JD6) J6, (JXD2) JD, (JXD2H) J2, (JXD6) JX, (JXD6H) JH, (SJD6H) SH, (SJD6) SJ, (SHJD6) SX, (SHJD6H) SY, (SCJD6) SC, (CLD6) CL, (HLD6) HL, (LD6) L6, (LXD6) LX, (SLD6) SL, (SHLD6) S2, CM, (CMD6H) CH, (HMD6) HM, (HMXD6) HR, (HMXD6H) HS, (MD6) MD, (MXD6) MX, (MXD6H) MH, SCMD6 (SO), SCMD6H (SQ), SMD6 (SM), SMD6H (AX), SHMD6 (S5), SHMD6H (S6)(CND6) CN, (CND6H) C6, (HND6) HN, (HNXD6) HT, (HNXD6H) HX, (ND6) ND, (NXD6) NX, (NXD6H) NT, SCND6 (SR), SCND6H (ST), SND6 (SN), SHND6 (AD), SND6H (AY) 6-8 Siemens Canada Limited Power Product Catalogue Panelboards Type P1 Panelboards Reference Features and Benefits The standard Siemens P1 panelboard has some unique features that make it easier to design for an engineer, easier to reconfigure in the field for a contractor, and easier to upgrade and maintain for the owner. What makes it different is its split neutral design and its open ended bus. In the Siemens panel, instead of the common single neutral bus on one end, there is a neutral bus on both sides that is cross-bussed. This makes branch wiring simpler and cleaner – the lead lengths for line and neutral can now be made the same, creating more room and a neater installation. It also allows access to both ends of the bus as a standard feature – this provides the flexibility to make changes in the field, even if it wasn’t part of the original configuration. MAIN BREAKER or SUB-FEED BREAKER MAIN LUGS or FEED-THROUGH LUGS 6 PANELBOARDS INTEGRAL BUS MOUNTED SPD The following can be done to a standard P1 panelboard in the field with no modifications: b b b b b b b Change from top fed to bottom fed Add feed-through lugs Add an Integral bus-mounted SPD Add a sub feed breaker up to 250 amps Change from Main Lugs to Main Breaker Change from Main Breaker to Main Lugs Panel may have up to two ground assemblies. Options are standard aluminum, copper, insulated or isolated aluminum or copper. Mounting provisions in opposing corners of the box are standard. Any of these options may be added after installation. Siemens Canada Limited Power Product Catalogue 6-9 Panelboards Type P1 Panelboards Voltage - 600Y/347V AC Max. 250V DC Max. Amperage - 400 amp Max. Mains 100 amp Max. Branch Short Circuit Rating 100,000 A @ 240Vac* Branch breaker symmetrical interrupting capacity based on CSA's test procedures Feed thru and subfeed lugs may result in lower interrupting ratings if not protected by a main device. Consult sales office. PANELBOARDS 6 Panelboards Certified by CSA under file #165172 Listed by Underwriters’ Laboratories, Inc., under ”Panelboards” File #E2269 for interiors and #E4016 for boxes and fronts. Service 1-phase 2-wire - 120 Vac, 240 Vac, 24 Vdc, 48 Vdc, 125 Vdc 1-phase 3-wire - 120/240 Vac, 125/250 Vdc 3-phase 3-wire - 600Y/347 Vac. and 480Y/277 (when derived from 3-phase 4-wire system), 240 Vac, 120 Vac, 125/250 Vdc 3-phase 4-wire - 208Y/120 Vac, 240/120 Vac, 480Y/277 Vac, 600Y/347 Vac. Enclosure Type 1 enclosure 20” wide x 5.75” deep. b End walls are blank as standard. End walls with knockouts are available. General Ampere Rating Connector Wire Range 100 (1) #14 - 1/0 AWG Al/Cu 125 (1) #4 - 1/0 AWG Al/Cu 225 (1) #4 AWG - 300 kcmil Al/Cu 250 (1) #4/0 AWG - 350 kcmil Al or (1) #6/0 AWG - 350 kcmil Cu 400 (1) #4/0 AWG - 500 kcmil Al or (2) #3/0 AWG - 500 kcmil Cu 125 (1) #6 AWG - 350 kcmil Al/Cu 250 (1) #6 AWG - 350 kcmil Al/Cu 400 (2) 1/0 AWG - 250 kcmil Al/Cu or (1) #2 AWG - 600 kcmil Al/Cu Main Breaker Wire Bending Space Inches (mm) Neutral Location Side Gutter Main Breaker BL, BLH, HBL, BQD, BQD6 NGB ED2, ED4, ED6, HED4 QJ2, QJH2, QJ2-H FD6, FXD6, HFD6 20" w/box 24" w/box (optional) 20" w/box 8.500 (216) 10.500 (267) 11.500 (292) 8.000 (203) 6.125 (156) 6.500 (165) 5.250 (133) 15.000 (381) 10.000 (254) 8.125 (206) 8.500 (216) 7.250 (184) 15.000 (381) 11.500 (292) 11.500 (292) 11.500 (292) 11.500 (292) 26.750 (680) Main Lug End Gutter Dimensions Inches (mm) Amp Rating End Gutter Neutral Location 125 10.500 (267) 11.500 (292) 250 10.500 (267) 11.500 (292) 400 25.500 (648) 26.750 (680) * IR rating will depend on the type of main breaker applied or if main breaker is “Series Rated” with an up stream protective device (circuit breaker or fuse). P1 400 amp main breaker panels have wire bending space available for 600 kcmil. main breaker is vertical mounted. 400A 6-10 Panel Width 20" Panel Width 24" (Optional) A 6.375 (162) 7.375 (187) B 5.500 (140) 7.500 (191) C 6.125 (156) 8.125 (206) D 6.500 (165) 8.500 (216) E 5.250 (133) 7.250 (184) Branch Breaker Side Gutters Main Lug Connectors (phase) Main Breakers BL, BLH, HBL, BQD, BQD6, ED2, NGB, ED4, ED6, HED4, QJ2, QJH2, QJ2-H, FXD6, FD6, HFD6, JXD6, JD6, HJXD6, HJD6. (All main breakers except 400 amp frame are mounted horizontal.) Reference Letter Connector ranges indicated do not apply to all main breaker types. Refer to molded case circuit breaker standard pressure wire connector chart (Section 5) for the connector range of a specific frame. JXD6, HJD6 Panelboard Trims and Doors Standard panelboards are furnished with trim featuring concealed fasteners and hinges with a flush door lock. All are factory-assembled for ease of installation. Trims are fabricated from code gauge steel and finished ANSI-61 grey paint. See page 6-6 for optional fronts. Side Gutter Wiring Space - Inches (mm) Main Breaker Panel Connectors Feed-thru lug and neutral wire bending space is 15.000" (381mm) and 16.250" (413mm) respectively on 400A panel. panel limited to (1) subfeed 250 amperes max. P1 Siemens Canada Limited Power Product Catalogue Weight — Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is: b About 3 lbs. (1kg) per inch (54g per mm) of box height Gauge Steel Boxes Width - in (mm) Height - in (mm) Gauge Steel 20 (508) All #14 Gauge Steel Trims - Surface, Flush 20 (508) All #14 Series Connected Short Circuit Ratings The term “Series Connected Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by CSA. Series ratings must be specified on order at time of entry. See Circuit Breaker Section of this book for combinations available. Panelboards Distributor Stock - Type P1 Reference Interior Numbering System Type P1 Unassembled Panels are completely convertible from main lug to main breaker and vice-versa. Additionally, feed-thru lugs or a subfeed circuit breaker up to 250 amperes can be added without increasing the box height. P 1 C 1 8 ∂ ∂ ∂ ∂ ∂ M C ∂ ∂ 2 5 0 A ∂ ∂ ∂ ∂ 1. P1 Interior 2. Voltage and System A = 120/240V, 1-Phase 3-Wire C = 208Y/120V, 3-Phase 4-Wire L = 600Y/347V, 3-Phase 4-Wire 3, 4. Circuit – 18, 30, 42 5, 6. Mains ML = Main Lug MC = Convertible Mains Select Main Lug Kit or Breaker Mounting Kit on page 6-13 and 6-14 Select Main Breaker Kit on page 6-13 and 6-14 7, 8, 9. Amperage – 400A max 10. Main Bus Material A = Aluminum C = Copper 6 PANELBOARDS Note: Standard bussing in P1 panels is tin plated for aluminum and copper. Standard bus is temperature rated to the maximum amperage in the panel. Branch Breakers Panel Type P1 Voltage (Max.) Breaker Type 240 BL, BLH, HBL, BQD, BQD6 Power Product Catalogue Page 600/347 BQD, BQD6 See section 5 Siemens Canada Limited Power Product Catalogue 6-11 Panelboards Distributor Stock - Type P1 Selection Interior, Box and Trim selection 400A Max. — 20" Wide x 5.75" Deep 1. Determine voltage, system, amperage, bussing material and type of main entry to select the appropriate Interior from the table below. 2. Select the type of box and trim needed and select the appropriate height based on the number of circuits. 3. Select main lug kit or main breaker kit. Note: Main/Subfeed breaker mounting kits may be ordered with or without breaker, see pages 6-13 and 6-14 for selection. 4. List required branch circuit breakers: Type BL, BQD or BQD6 breakers. 5. Select accessories on page 6-15. Type P1 Unassembled Panelboards Interiors Only – Less Branch Breakers Amperes Max. No. Rating Mains of Circuits Boxes Trims Height - Inches (mm) Type 1 Type 3R/12 Surface P1A18ML250A P1A30ML250A P1A42ML250A 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B P1A18MC400A P1A30MC400A P1A42MC400A P1A18ML400A P1A30ML400A P1A42ML400A 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B Cu P1A18MC250C P1A30MC250C P1A42MC250C P1A18ML250C P1A30ML250C P1A42ML250C 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B Cu P1A18MC400C P1A30MC400C P1A42MC400C P1A18ML400C P1A30ML400C P1A42ML400C 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B 250 18 30 42 Al P1C18MC250A P1C30MC250A P1C42MC250A P1C18ML250A P1C30ML250A P1C42ML250A 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B 400 18 30 42 Al P1C18MC400A P1C30MC400A P1C42MC400A P1C18ML400A P1C30ML400A P1C42ML400A 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B 250 18 30 42 Cu P1C18MC250C P1C30MC250C P1C42MC250C P1C18ML250C P1C30ML250C P1C42ML250C 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B 400 18 30 42 Cu P1C18MC400C P1C30MC400C P1C42MC400C P1C18ML400C P1C30ML400C P1C42ML400C 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B 250 18 30 42 Al P1L18MC250A P1L30MC250A P1L42MC250A P1L18ML250A P1L30ML250A P1L42ML250A 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B 400 18 30 42 Al P1L18MC400A P1L30MC400A P1L42MC400A P1L18ML400A P1L30ML400A P1L42ML400A 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B 250 18 30 42 Cu P1L18MC250C P1L30MC250C P1L42MC250C P1L18ML250C P1L30ML250C P1L42ML250C 32 (813) 38 (965) 44 (1118) B32 B38 B44 WP32 WP38 WP44 S32B S38B S44B F32B F38B F44B 400 18 30 42 Cu P1L18MC400C P1L30MC400C P1L42MC400C P1L18ML400C P1L30ML400C P1L42ML400C 56 (1422) 62 (1575) 68 (1727) B56 B62 B68 WP56 WP62 WP68 S56B S62B S68B F56B F62B F68B Main Bus Material Convertible Main Main Lug 250 18 30 42 Al P1A18MC250A P1A30MC250A P1A42MC250A 400 18 30 42 Al 250 18 30 42 400 18 30 42 PANELBOARDS 6 1-Phase, 3-Wire 120/240V 3-Phase, 4-Wire 208Y/120V 3-Phase, 4-Wire 600Y/347V Hinged door included with type 3R/12 enclosures. trims extend 3/4" beyond each side of the base box dimensions. Flush 6-12 Flush Siemens Canada Limited Power Product Catalogue Panelboards Distributor Stock - Type P1 Selection Main Entry Kit Selection Main Breaker Mounting Kits with Breakers Max. Interrupting Rating (kA) Catalogue Number Description 240V 480V MBKBL12100 Kit with 2-Pole BL 100A Breaker 10 – – MBKBL33100 Kit with 3-Pole BL 100A Breaker 10 – – MBKQJ12225 Kit with 2-Pole QJ2 225A Breaker 10 – – MBKQJ33150 Kit with 3-Pole QJ2 150A Breaker 10 – – MBKQJ33200 Kit with 3-Pole QJ2 200A Breaker 10 – – MBKQJ33225 Kit with 3-Pole QJ2 225A Breaker 10 – – MBKED33100 Kit with 3-Pole ED6 100A Breaker 65 25 18 MBKED33125 Kit with 3-Pole ED6 125A Breaker 65 25 18 MBKFD33200 Kit with 3-Pole FXD6 200A Breaker 65 35 22 MBKFD33225 Kit with 3-Pole FXD6 225A Breaker 65 35 22 MBKFD33250 Kit with 3-Pole FXD6 250A Breaker 65 35 22 MBKHF33250 Kit with 3-Pole HFD6 250A Breaker 100 65 25 Kit with 3-Pole JXD6 400A Breaker 65 35 25 MBKJD33400 600V MBKFD33250 (Breaker included) Breaker Mounting Kits without Breaker – Main or Subfeed (250A max.) Amp Rating 100 Breaker Types BL, BLH, HBL 125 ED2, ED4, ED6, HED4 225 QJ2, QJH2, QJ2-H 400 JD6, JXD6, HJD6 3 Phase MBKBL3 1 Phase MBKED1 3 Phase MBKED3 1 Phase MBKQJ1 3 Phase MBKQJ3 1 Phase MBKFD1 3 Phase MBKFD3 1 Phase MBKJD1 3 Phase MBKJD3 MBKFD3 (Breaker not included) PANELBOARDS FXD6, FD6, HFD6 Catalogue Number MBKBL1 6 250 Service 1 Phase Lug Kits – Main and/or Feed-Thru Amp Rating Material Wire Range Al (1) #6 AWG - 350 kcmil Al/Cu 250 Cu (1) #6 AWG - 350 kcmil Cu Al (2) 1/0 - 250 kcmil Al/Cu or (1) #2 AWG - 600 kcmil Al/Cu Cu (1) 1/0 AWG - 600 kcmil Cu or (2) 1/0 AWG - 4/0 AWG Cu 400 400 amp kits is for main only - not allowed as subfeed breaker. Main Service Catalogue Number 1 Phase MLKA1 3 Phase MLKA3 1 Phase MLKC1 3 Phase MLKC3 1 Phase 4MLKA1 3 Phase 4MLKA3 1 Phase 4MLKC1 3 Phase 4MLKC3 breaker selection p. 6-14. Siemens Canada Limited Power Product Catalogue 6-13 Panelboards Circuit Breaker / Lighting and Distribution Selection Type P1 Panelboards Main Breaker Selection Ampere Rating Breaker Type Maximum Interrupting Rating (kA) 240 Vac 480/277 Vac 600Y/347 Vac Catalogue Number Available Trip Values 70 BQD6 65 — 10 B6 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 100 BL BLH HBL BQD ED2 10 22 65 65 10 — — — 14 — — — — — — BL BH HB BQ E2 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 125 NGB ED4 ED6 HED4 100 65 65 100 25 18 25 42 14 — 18 — NB E4 E6 H4 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 225 QJ2 QJH2 QJ2-H FD6 FXD6 HFD6 10 22 42 65 65 100 — — — 35 35 65 — — — 22 22 25 QJ QH Q2 FD FX HF 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 250 FD6 FXD6 HFD6 65 65 100 35 35 65 22 22 25 FD FX HF 250 250 250 400 JD6 JXD6 HJD6 65 65 100 35 35 65 25 25 35 J6 JX H6 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 Subfeed Breakers PANELBOARDS 6 Breaker Type QJ2 Number of Poles Max. Interrupting Rating (kA) 240V 480Y/277V 600Y/347V 2, 3 10 — — Available Trip Values 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 QJH2 2, 3 22 — — 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 QJ2H 2, 3 42 — — 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 ED2 2, 3 10 — — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 ED4 2, 3 65 18 — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 ED6 2, 3 65 25 18 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 HED4 2, 3 100 42 — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 FXD6 2, 3 65 35 22 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 FD6 2, 3 65 35 22 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 HFD6 2, 3 100 65 25 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 Note: For detailed circuit breaker information please consult section 5. For "Series Rating" tested combinations, please consult the Siemens Series Rated Combination Guide p. 5-84. 6-14 Please consult CSA, CEC and local inspection authorities for specification and installation guidelines. No increase in box height, space is already built into P1 panel. Siemens Canada Limited Power Product Catalogue Amperage available in 3 pole breaker only. Panelboards Circuit Breaker/Lighting and Distribution Selection Branch Breakers Selection Guide for P1 3. Select number of poles. 4. Select branch breaker catalogue numbers on page 6-16. 1. Select branch breaker type based on interrupting rating required. 2. Select required amperage. 5. Select ground bar and filler to cover any unused positions. (See replacement parts & accessories on page 6-17.) Branch Circuit Breakers Breaker Type Number of Poles Max. Interrupting Rating (kA) 120V 120/240V 240V 277V 480/277V 347V 600/347V BL 1 2 3 10 — — — 10 — — — 10 — — — — — — — — — — — — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 BLH 1 2 3 22 — — — 22 — — — 22 — — — — — — — — — — — — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 HBL 1 2 3 65 — — — 65 — — — 65 — — — — — — — — — — — — 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100 BLR 2 — — 10 — — — — 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 BLF 1 2 10 — — 10 — — — — — — — — — — 15, 20, 25, 30 15, 20, 30, 40, 50, 60 BLHF 1 2 22 — — 22 — — — — — — — — — — 15, 20, 25, 30 15, 20, 30, 40, 50, 60 BLE 1 2 10 — — 10 — — — — — — — — — — 15, 20, 30 15, 20, 30, 40, 50, 60 BLEH 1 2 22 — — 22 — — — — — — — — — — 15, 20, 30 15, 20, 30, 40, 50, 60 BAF 1 10 — — — — — — 15, 20 BAFH 1 22 — — — — — — 15, 20 BQD 1 2 3 65 — — — — — — 65 65 14 — — — 14 14 — — — — — — 15, 20, 25, 30, 35, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 45, 50, 60, 70, 80, 90, 100 BQD6 1 2 3 65 — — — — — — 65 65 — — — — — — 10 — — — 10 10 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 Available Trip Values BLE, BLEH PANELBOARDS BQD, BQD6 6 BL, BLH, HBL BAF, BAFH Siemens Canada Limited Power Product Catalogue 6-15 Panelboards Circuit Breaker/Lighting and Distribution Selection Branch Breakers Selection for P1 BL Branch Breakers – 10,000A IR AFCI – Branch Feeder Catalogue Number Ampere Rating 15 20 25 30 35 40 45 50 55 60 70 80 90 100 1-Pole 120/240V 2-Pole 120/240V 2-Pole 240V 3-Pole 240V B115 B120 B125 B130 B135 B140 B145 B150 B155 B160 B170 — — — B215 B220 B225 B230 B235 B240 B245 B250 — B260 B270 B280 B290 B2100 B215R B220R B225R B230R B235R B240R B245R B250R — B260R B270R B280R B290R B2100R B315 B320 B325 B330 B335 B340 B345 B350 — B360 B370 B380 B390 B3100 BLH Branch Breakers – 22,000A IR Breaker Type Ampere Rating Catalogue Number BAF - 10,000 IR 1-pole 15 20 B115AF B120AF BAFH - 22,000 IR 1-pole 15 20 B115AFH B120AFH GFCI Personnel Protection (5mA) Breaker Type Ampere Rating Catalogue Number BLF - 10,000 IR 1-pole 15 20 25 30 BF115 BF120 BF125■ BF130 BLF - 10,000 IR 2-pole 15 20 30 40 50 60 BF215 BF220 BF230 BF240■ BF250■ BF260■ BLHF - 22,000 IR 1-pole 15 20 25 30 BF115H BF120H BF125H■ BF130H BLHF - 22,000 IR 2-pole 15 20 30 40 50 60 BF215H BF220H BF230H BF240H■ BF250H■ BF260H■ Catalogue Number PANELBOARDS 6 Ampere Rating 15 20 25 30 35 40 45 50 55 60 70 80 90 100 1-Pole 120/240V 2-Pole 120/240V 3-Pole 240V B115H B120H B125H B130H B135H B140H B145H B150H B155H B160H B170H — — — B215H B220H B225H B230H B235H B240H B245H B250H B255H B260H B270H B280H B290H B2100H B315H B320H B325H B330H B335H B340H B345H B350H B355H B360H B370H B380H B390H B3100H HBL Branch Breakers – 65,000A IR Catalogue Number Ampere Rating 15 20 25 30 35 40 45 50 55 60 70 80 90 100 1-Pole 120/240V 2-Pole 120/240V 3-Pole 240V B115HH B120HH B125HH B130HH B135HH B140HH B145HH B150HH B155HH B160HH B170HH — — — B215HH B220HH B225HH B230HH B235HH B240HH B245HH B250HH B255HH B260HH B270HH B280HH B290HH B2100HH B315HH B320HH B325HH B330HH B335HH B340HH B345HH B350HH B355HH B360HH B370HH B380HH B390HH B3100HH BQD6 Branch Breakers – 10,000A IR max. @ 600/347 Vac Catalogue Number Ampere Rating 15 20 25 30 35 40 45 50 60 70 ■ Built to order. 6-16 1-Pole 347V 2-Pole 600Y/347V 3-Pole 600Y/347V BQD6115 BQD6120 BQD6125 BQD6130 BQD6135 BQD6140 BQD6145 BQD6150 BQD6160 BQD6170 BQD6215 BQD6220 BQD6225 BQD6230 BQD6235 BQD6240 BQD6245 BQD6250 BQD6260 BQD6270 BQD6315 BQD6320 BQD6325 BQD6330 BQD6335 BQD6340 BQD6345 BQD6350 BQD6360 BQD6370 GFCI Equipment Protection (30mA) Breaker Type Ampere Rating Catalogue Number BLE - 10,000 IR 1-pole 15 20 30 BE115 BE120 BE130 BLE - 10,000 IR 2-pole 15 20 30 40 50 60 BE215 BE220 BE230 BE240 BE250 BE260■ BLEH - 22,000 IR 1-pole 15 20 30 BE115H BE120H BE130H BLEH - 22,000 IR 2-pole 15 20 30 40 50 60 BE215H BE220H BE230H BE240H BE250H BE260H■ BQD Branch Breakers – 65,000A IR max. @ 240 Vac Catalogue Number Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 To add shunt trip to BL breakers, see page 6-18 Accessories. Siemens Canada Limited Power Product Catalogue 1-Pole 120/240V 2-Pole 120/240V 3-Pole 240V BQD115 BQD120 BQD125 BQD130 BQD135 BQD140 BQD145 BQD150 BQD160 BQD170 BQD180 BQD190 BQD1100 BQD215 BQD220 BQD225 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290 BQD2100 BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 BQD370 BQD380 BQD390 BQD3100 To add shunt trip to BQD breakers, see page 6-18 Accessories. Panelboards Modifications and Additions Selection Type P1 Panelboards Copper Neutral Lug Kits - 250A Number of Circuits Description Catalogue Number 18 30 42 CNLK18 CNLK30 CNLK42 2 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 200% Copper Neutral Lug Kits - 250A 18 30 42 2NLK18 2NLK30 2NLK42 2 Branch Neutral Strips, 2 Main Neutral Lug, Hardware CNLK42 200% Copper Neutral Lug Kits - 400A 18 30 42 42NLK18 42NLK30 42NLK42 2 Branch Neutral Strips, 1 Main 600 kcmil Neutral Lug, Hardware 250A Branch Neutral Connections No. of connections per neutral bar No. of circuits Branch Neutral Lugs - Wire Size range 18 circuits 30 circuits (1) #6 - 350 MCM Al/Cu 42 circuits Al Neutral bar Std Cu Neutral bar (2) #4 - #14 AWG (8) 1/0 - #14 AWG (9) #4 - #14 AWG (8) 1/0 - #14 AWG (2) #4 - #14 AWG (15) 1/0 - #14 AWG (16) #4 - #14 AWG (15) 1/0 - #14 AWG (22) 1/0 - #14 AWG (23) #4 - #14 AWG (22) 1/0 - #14 AWG 2NLK42 400A Branch Neutral Connections Branch Neutral Lugs - Wire Size range 30 circuits (1) #2 - 600 MCM Al/Cu 42 circuits Al Neutral bar Std Cu Neutral bar (2) #4 - #14 AWG (8) 1/0 - #14 AWG (9) #4 - #14 AWG (8) 1/0 - #14 AWG (2) #4 - #14 AWG (15) 1/0 - #14 AWG (16) #4 - #14 AWG (15) 1/0 - #14 AWG (22) 1/0 - #14 AWG (23) #4 - #14 AWG (22) 1/0 - #14 AWG Type P1 Miscellaneous Parts and Accessories Catalogue Number Description 12-1110-01 1 Directory card for 1-42 circuits 11-1824-01 1 Plastic directory card holder MCHK 1 Metallic directory card holder 10FLHX2 200 BL/BQD breaker line side screws 10FLHX5 500 BL/BQD breaker line side screws FPLK2 2 Spare Fas-latch trim locks with 2 keys BK1 1 Bonding kit for P1 panels EGK 1 Aluminum non-insulated ground bar ECGK 1 Copper non-insulated ground bar EWK1 1 End Wall with knockouts (20" W x 5.75" D) IGK 1 Insulated Al ground bar ICGK 1 Insulated Cu ground bar IMK1 1 Interior adjusting kit JCK24 24 Trim screws and 24 trim clips NBK03 1 Number Strip 1-42 circuits QF3-UL 1 Filler Plate SDKN 1 Dripshield kit (20" W x 5.75" D) TPS9IKITP1 1 P1 mounting bracket for SPD TPS3 09 PANELBOARDS 18 circuits 6 No. of connections per neutral bar No. of circuits NBK03 Type P1 Spare Part Kit Catalogue Number MHKP1 Content b b b b b b 8 trim screws 8 trim clips 1 bonding kit 1 interior adjusting kit 2 Al non-insulated ground bar 2 Cu non-insulated ground bar b 2 Insulated AI ground bar b b b b b 2 Insulated Cu ground bar 1 numbering strip label 1 directory card 1 plastic directory pouch 1 panelboard instruction book Siemens Canada Limited Power Product Catalogue 6-17 Panelboards Type P1 Panelboard Factory Assembled / Modifications and Additions Enclosure Modifications Type 1 with gasket Type 1 with dripshield Type 3R - Waterproof and silicone free Type 3R/12 - Dustproof Type 4/4X - Standard type 304 Stainless Steel Type 4/4X - Type 316 Stainless Wider enclosure - 24” wide Hinged trim Piano hinged trim Trim with padlock Door-in-door trim Screw to the box trim Trim with gasketed door Stainless steel trim Painted boxes Custom colours Panel Skirts See page 6-47 Panel Modifications b b b b Type P1 Panelboards are factory labeled “SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT” when identified as "Service Entrance" at the time of order entry. For regulations governing this feature, please consult CEC, CSA or local electrical authorities. Bus Material Represented by “A”, “C” or “E” in the 11th digit of the catalogue number Standard bussing is tin plated Al, alternate bus bar material can be selected: TPS3 01 - Bus connected - Internally mounted (30A breaker required to feed SPD) - Externally mounted in a 15” high aux. enclosure (30A breaker required to feed SPD) b TPS3 09 - Internally mounted (20A breaker required to feed SPD) - Externally mounted (20A breaker required to feed SPD) b TPS3 12 - Externally mounted (40A breaker required to feed SPD) Feed-Thru Lugs Cannot be used in conjonction with SPD or subfeed breakers Ampere Rating 250 Type Connector Wire Range Al Mechanical (1) #6 AWG - 350 kcmil Al/Cu Cu Mechanical (1) #6 AWG - 350 kcmil Cu Compression (1) #6 AWG - 350 kcmil Al/Cu Al Mechanical (2) #3/0 AWG - 250 kcmil Al/Cu or (1) #3/0 AWG - 600 kcmil Al/Cu Compression Lugs Style Amp Rating Breaker Type Compression Connector Wire Range Box Height Addition N/A (1) #4 AWG - 350 kcmil Al/Cu None 400 N/A (1) 250 - 600 kcmil or (2) #3/0 AWG - 250 kcmil None 125 ED4, ED6, HED4 (1) #12 - 1/0 AWG Al/Cu Box must go to 24" wide 250 FXD6, HFD6 (1) #6 AWG - 350 kcmil Al/Cu Box must go to 24" wide 125 MLO Main Breaker 250 Note: Standard compression lugs used for P1 are range taking lugs and may require a particular crimping tool to accommodate the range. Consult factory for information. b Tin plated copper b Silver plated copper - optionnal Branch and Main Breaker and Accessories see section 6 b Non-Insulated Equipment Ground Bar Copper Non-Insulated Ground Bar Al Insulated Equipment Ground Bar Cu Insulated Equipment Ground Bar 400 Service Entrance Label 6 Ground Bars are shipped with the panel interior factory mounted. BL, BLH, HBL, BQD, BQD6 as branch only. BL, BLH, HBL, ED4, ED6, HED4, uses 1” unit space for shunt trip as a branch device. All others may be used on mains or subfeeds. b Pilot lights b Toggle switches b Push buttons (Devices mounted into a 10" minimum box extension) See section 5 b Handle blocks b Handle locks 6-18 Surge Protective Devices Shunt Trip on Main or Branch Mounted devices PANELBOARDS Panel Modifications (cont.) Grounding of Panelboards Description Selection Siemens Canada Limited Power Product Catalogue Panelboards Panelboard Replacement, Modification, and Additions Selection S1/S2 Panels—All the P1 panel kits for 250 amp and below panels will work for 250 amp maximum S1/S2 panels. 400/600 Amp S1/S2 Lug Kits — Main or Feed-Thru Ampere Rating Material Wire Range Service Catalogue Number 125A/250A Al/Cu (2) 1/0–250 kcmil 1-Phase MLKA1 125A/250A Al/Cu (2) 1/0–250 kcmil 3-Phase MLKA3 400A/600A Al/Cu (2) #4–250 kcmil or (1) 3/0–500 kcmil 1-Phase SMLKA1 400A/600A Al/Cu (2) #4–250 kcmil or (1) 3/0–500 kcmil 3-Phase SMLKA3 Service Catalogue Number SMBKED1 Breaker Mounting Kits Ampere Rating Breaker Types 125A ED2, ED4, ED6, HED4, HED6, HHED6 1-Phase 225A ED2, ED4, ED6, HED4, HED6, HHED6 3-Phase SMBKED3 225A QJ2, HQJ2, HQJ2H 1-Phase SMBKQJ1 225A QJ2, HQJ2, HQJ2H 3-Phase SMBKQJ3 250A FXD6, FD6, HFXD6, HFD6 1-Phase SMBKFD1 250A FXD6, FD6, HFXD6, HFD6 3-Phase SMBKFD3 400A JD6, JXD6, HJD6, HJXD6 1-Phase SMBKJD1 400A JD6, JXD6, HJD6, HJXD6 3-Phase SMBKJD3 600A LD6, LXD6, HLD6, HLXD6 1-Phase SMBKLD1 600A LD6, LXD6, HLD6, HLXD6 3-Phase SMBKLD3 Neutral Kits Catalogue Number 250A max. 30/42 circuit 200% neutral kit 2NLK2 400/600A max. 42 circuit 200% neutral kit 2NLK1 PANELBOARDS Description 6 Ampere Rating QJ mounting kit is for subfeed breakers only, not main breaker. The kit contains mountings for (2) breakers. Siemens Canada Limited Power Product Catalogue 6-19 Panelboards Type P1 Dimensions Type 1 Box Box is symmetrical P1 250A: 18, 30, 42 ccts Type 3R and 3R/12 Box PANELBOARDS 6 P1 400A: 18, 30, 42 ccts P1 250A: 18, 30, 42 ccts P1 400A: 18, 30, 42 ccts Dimensions are interior of the box. Add 5/8" [16mm] to width for absolute dimension. Add 1/8"[3mm] to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. 6-20 Siemens Canada Limited Power Product Catalogue Panelboards Type P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factoryassembled options to meet almost all lighting panel applications. With this design, the ability to mix breaker frames in unit space up to 250 amps will also meet many distribution panel requirements in a much smaller package. Bussing options for the P2 are aluminum and copper. Standard bussing in the P2 panel is tin-plated. Silver-plated copper is also offered as an option. Bus mounted contactors, as mains or sub mains, and subfeed lugs (up to 400 amp) are just a few of the options of this unique panel. P2 is set up around 18, 30, 42, 54, 66, 78, 90, 102.114 circuit configurations. It will also allow the user to configure the panel to the smallest possible size. The P2 panel starts with 9" of unit space (18 circuits of 1" pole breakers). Breakers mounted in unit space can be mixed and matched to meet customer requirements. All 1" pole breakers (BL, BQD, ED frames) are mounted in 3" or 6" pole increments. Breaker frames, above 125 amps, are mounted in 6" single breaker mountings. Branch Breaker Side Gutter Wiring Space - Inches (mm) Reference Letter Amperage – 600 amp max. Short circuit rating 200,000 A IR Maximum / 100,000 A @ 600 Vac symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to 22 KAIC or the lowest rated device installed unless a series combination rating for a main or remote main is indicated. Note that the main device may be mounted remote from the panel. Panelboards Certified by CSA under file #165172 Listed by Underwriters' Laboratories Inc., under "Panelboards" File #E2269 for the interiors and #E4016 for boxes and fronts. Bussing – The P2 panel has more options to meet market requirements. The standard bussing is tin-plated aluminum for amperage up to 400A and is tin-plated copper for 600A. The rating is per the requirements of CSA 22.2 No.29 – the standard for panelboards. The copper bus option for this panel is tin-plated or silver flash. Enclosure – Standard Type 1 enclosure is 20" wide x 5.75" deep. Box Height is determined by main device and unit space. See charts for box height. Panelboards Fronts and Doors Standard panelboards are furnished with trim featuring concealed fasteners and hinges with flush door lock. All are factory assembled for ease of installation. Trims are fabricated from code gauge steel and finished ANSI-61 grey paint. See page 6-6 for optional fronts. Main Breakers BL, BLH, HBL, BQD, BQD6, ED2, ED4, ED6, HED4, CED6, NGB, QJ2, QJH2, QJ2-H, FXD6, FD6, HFD6, CFD6, JXD6, JD6, HJD6, SHJD6, CJD6, SCJD6, LXD6, LD6, HLD6, SLD6, SHLD6, CLD6, SCLD6. A B C D E Panel Width 20" (508) 5.750 (146) 5.125 (130) 4.000 (102) 5.000 (127) 4.625 (117) Branch Breaker Side Gutters A B C D E BL, BLH, HBL BL, BLH, HBL BLF, BLFH BLF, BLFH BQD, BQD6 BQD, BQD6 ED2, ED4, ED6 ED2, ED4, ED6 HED4 HED4 QJ2, QJH2, QJ2-H, HQJ2H (Single Mounted) NGB NGB A B C E Panel Width 20 in. (508 mm) Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is: b About 3 lbs. (1kg) per inch (54g) per mm of box height Gauge Steel Boxes Width - in (mm) Height - in (mm) Gauge Steel 20 (508) 26-74 (660-1880) #14 Gauge Steel Trims - Surface, Flush 20 (508) 26-74 (660-1880) #14 Series Connected Short Circuit Ratings The term “Series Connected Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by CSA. Series ratings must be specified on order at time of entry. See Circuit Breaker Section of this book for combinations available. Siemens Canada Limited Power Product Catalogue 6-21 PANELBOARDS Another unique feature of the P2 panel is that blank unit space can be added to allow for future expansions or modifications. Any expansions or modifications must be in 3" increments. BL, BQD, and ED frame breakers have 3" or 6" pole kits, and can be mixed in unit space by these increments. Breakers of the same frame can cross from one mounting to another if contiguous. QJ frame breakers are mounted in 6" increments for two- and three pole, single mounted units. Changes in the unit space length for BL, BQD, or ED frame breakers require an addition deadfront, center strip kit. Check with sales or the factory for additional unit space kits. Voltage – 600V AC max. 250V DC max. 6 As an example of a minimum panel, (6) 20 amp 1-pole BL breakers (3" of unit space) and a 3-pole 225 amp QJ breaker (6" of unit space) equaling 9" of unit space can be configured in a P2 panel without any extra provisions or space required. FD 250 amp and JD 400 amp breakers are mounted as subfeed breakers outside of unit space. General Panelboards Type P2 Panelboards Selection/Dimensions P2 Box Size Requirements Base Box Size Requirements for P2 Panels with Standard Line Lugs are for 1" module (BL, BQD, ED, NGB) branch breakers and provisions. Unit Spaces range from 9" to 57" (in 6" increments). Boxes range from 26" to 74" high (in 6" increments). Inclusion of optional modifications may require size increases that must be added to these base values to calculate the final box size for the panel (see pages 6-29, 6-30). For service entrance application, breaker is vertically mounted only. - “A” dimension 26 (660) 32 (813) P2 Panels, with standard Line lugs unit space (starting with 9” and adding 6” increments) Main Lugs Main Breakers 125A 225A 225A 250A 250A 125A Horiz. 125A Vert. Horiz. Horiz. Horiz. Vert. Vert. 400A BL, BQD, QJ CED QJ FD FD ED 125A 250A 600A NGB, ED 9 — — 9 — — — — — — 15 9 — 15 9 9 9 — — — 250A CFD — — 400A JD — — 400A CJD — — 600A LD — — 600A CLD — — 38 44 50 56 62 68 74 21 27 33 39 45 51 57 — — 9 15 21 27 33 — — 9 15 21 27 33 — — — — 9 15 21 — — — 9 15 21 27 — — — — 9 15 21 Box Height Inches (mm) “B” dimension (965) (1118) (1270) (1422) (1575) (1727) (1880) 15 21 27 33 39 45 51 9 15 21 27 33 39 45 21 27 33 39 45 51 57 15 21 27 33 39 45 51 15 21 27 33 39 45 51 15 21 27 33 39 45 51 9 15 21 27 33 39 45 9 15 21 27 33 39 45 — 9 15 21 27 33 39 Main breaker wire bending space diagram Side Gutter Neutral Location C D BL 5.75 (146) 8.00 (203) BQD 5.13 (130) 8.00 (203) NGB 4.63 (118) 8.00 (203) ED (horiz.) 4.00 (102) 8.00 (203) 6 ED (vert.) 6.56 (167) 11.13 (283) PANELBOARDS Main Breaker Wire Bending Space - Inches (mm) QJ (horiz.) 5.00 (127) 7.00 (178) QJ (vert.) 10.06 (256) 16.69 (423) FD (horiz.) 5.00 (127) 7.00 (178) FD (vert.) 13.25 (337) 22.72 (577) 400 JD 15.38 (391) 25.00 (635) 600 LD 15.38 (391) 23.00 (584) Panel Amps Breaker Frames 100 125 225 250 Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A Main lug wire bending space diagram Main Lug Connectors Side Gutter Neutral Location C D Panel Amps Std Connectors for Al interior Std Connectors for Cu interior 125 (1) #6 - 2/0 AWG Al/Cu (1) #6 AWG - 350 kcmil Cu 6.62 (168) 8.19 (208) 250 (1) #6 - 350 kcmil Al/Cu (1) #6 AWG - 350 kcmil Cu 11.75 (298) 10.72 (273) 400 (1) #2 AWG - 600 kcmil Al/Cu or (1) 1/0 AWG - 250 kcmil Al/Cu (1) 1/0 AWG - 600 kcmil Cu or (2) 1/0 - 4/0 AWG Cu 14.00 (356) 13.09 (333) 600 (2) #2 AWG - 600 kcmil Al/Cu (2) #2 AWG - 600 kcmil Cu 14.00 (356) 11.00 (279) Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A Vertical main breaker application for ED, QJ and FD adds 6" (152mm) of box height. 6-22 Refer to wire bending space diagrams. Siemens Canada Limited Power Product Catalogue Panelboards Distributor Stock - Type P2 Main Lug Only Reference Interior Numbering System Type P2 unassembled panelboards are available as main lug only and come with provisions for the branch breaker type selected. I 2 C 4 2 ∂ ∂ ∂ ∂ ∂ M L ∂ ∂ 2 5 0 A - BL ∂ ∂ ∂ ∂ ∂ 1. P2 Interior (I2) 2. Voltage and System A = 120/240V, 1-Phase 3-Wire C = 208Y/120V, 3-Phase 4-Wire L = 600Y/347V, 3-Phase 4-Wire 3, 4. Circuit – 30, 42, 66, 78, 90 5, 6. Mains ML = Main Lug 7, 8, 9. Amperage – 600A max 10. Main Bus Material A = Aluminum C = Copper 6 11. Branch connector (provision) Type - BL, BQD, NGB, ED Panel Type P2 Voltage (Max.) Breaker Type 240 BL, BLH, HBL, BQD, BQD6 600/347 BQD, BQD6 PANELBOARDS Branch Breakers Power Product Catalogue Page See section 5 Siemens Canada Limited Power Product Catalogue 6-23 Panelboards Distributor Stock - Type P2 Main Lug Only Selection Interior, Box and Trim Selection 600A Max. — 20" Wide x 5.75" Deep 1. Determine voltage, system, amperage and type of branch breaker connectors to select the appropriate Interior from the table below. 2. Select the type of box and trim needed. 3. List required branch circuit breakers: Type BL, BQD, NGB or ED breakers. Type P2 Unassembled Panelboards Interiors Only - Less Branch Breakers Amperes Rating Mains Max. No. of Circuits Provision Type Boxes Main Lug + provisions Height Inches (mm) Trim Type 1 Type 3R/12 Surface 1-Phase, 3-Wire 120/240V 250 66 78 BL/BQD I2A66ML250A-BL I2A78ML250A-BL 56 (1422) 62 (1575) B56 B62 WP56 WP62 S56B S62B F56B F62B 400 42 66 BL/BQD I2A42ML400A-BL I2A66ML400A-BL 50 (1270) 62 (1575) B50 B62 WP50 WP62 S50B S62B F50B F62B 3-Phase, 4-Wire 208Y/120V 250 42 66 78 BL/BQD I2C42ML250A-BL I2C66ML250A-BL I2C78ML250A-BL 44 (1118) 56 (1422) 62 (1575) B44 B56 B62 WP44 WP56 WP62 S44B S56B S62B F44B F56B F62B 400 42 66 78 90 BL/BQD I2C42ML400A-BL I2C66ML400A-BL I2C78ML400A-BL I2C90ML400A-BL 50 62 68 74 (1270) (1575) (1727) (1880) B50 B62 B68 B74 WP50 WP62 WP68 WP74 S50B S62B S68B S74B F50B F62B F68B F74B 600 66 BL/BQD I2C66ML600A-BL 62 (1575) B62 WP62 S62B F62B PANELBOARDS 6 3-Phase, 4-Wire ED I2L30ML250A-ED 38 (965) B38 WP38 S38B F38B 42 ED NGB I2L42ML250A-ED I2L42ML250A-NGB 44 (1118) 44 (1118) B44 B44 WP44 WP44 S44B S44B F44B F44B 66 BQD6 ED NGB I2L66ML250A-BQD I2L66ML250A-ED I2L66ML250A-NGB 56 (1422) 56 (1422) 56 (1422) B56 B56 B56 WP56 WP56 WP56 S56B S56B S56B F56B F56B F56B 78 BQD6 ED I2L78ML250A-BQD I2L78ML250A-ED 62 (1575) 62 (1575) B62 B62 WP62 WP62 S62B S62B F62B F62B 42 BQD6 ED NGB I2L42ML400A-BQD I2L42ML400A-ED I2L42ML400A-NGB 50 (1270) 50 (1270) 50 (1270) B50 B50 B50 WP50 WP50 WP50 S50B S50B S50B F50B F50B F50B 66 BQD6 ED NGB I2L66ML400A-BQD I2L66ML400A-ED I2L66ML400A-NGB 62 (1575) 62 (1575) 62 (1575) B62 B62 B62 WP62 WP62 WP62 S62B S62B S62B F62B F62B F62B 78 BQD6 ED I2L78ML400A-BQD I2L78ML400A-ED 68 (1727) 68 (1727) B68 B68 WP68 WP68 S68B S68B F68B F68B 90 BQD6 ED I2L90ML400A-BQD I2L90ML400A-ED 74 (1880) 74 (1880) B74 B74 WP74 WP74 S74B S74B F74B F74B 66 BQD6 ED NGB I2L66ML600A-BQD I2L66ML600A-ED I2L66ML600A-NGB 62 (1575) 62 (1575) 62 (1575) B62 B62 B62 WP62 WP62 WP62 S62B S62B S62B F62B F62B F62B 400 600 600Y/347V 30 250 Flush Hinged door included with type 3R/12 enclosures. trims extend 3/4" beyond each side of the base box dimensions. Flush 6-24 Siemens Canada Limited Power Product Catalogue Panelboards Circuit Breaker/Lighting and Distribution Selection Type P2 Panelboards Main Breaker Selection Maximum Interrupting Rating (kA) Ampere Rating Breaker Type 240V AC 70 BQD6 100 BL BLH HBL BQD ED2 125 Ref. Catalogue Number Available Trip Values 600V AC 65 — 10 B6 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 10 22 65 65 10 — — — 14 — — — — — — BL BH HB BQ E2 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 NGB ED4 ED6 HED4 CED6 100 65 65 100 200 25 18 25 42 200 — — 18 — 100 NB E4 E6 H4 CE 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 125 QJ2 QJH2 QJ2H 10 22 42 — — — — — — QJ QH Q2 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 FD6 FXD6 HFD6 HFXD6 CFD6 65 65 100 100 200 35 35 65 65 200 22 22 25 25 100 FD FX HF H2 CF 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 250 FD6 FXD6 HFD6 HFXD6 CFD6 65 65 100 100 200 35 35 65 65 200 22 22 25 25 100 FD FX HF H2 CF 250 250 250 250 250 400 JXD6 JD6 HJD6 SJD6 SHJD6 CJD6 SCJD6 65 65 100 65 100 200 200 35 35 65 35 65 150 150 25 35 35 25 35 100 100 JX J6 H6 SJ SX CJ SC 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 300, 400 200, 300, 400 200, 225, 250, 300, 350, 400 200, 300, 400 600 LXD6 LD6 HLD6 SLD6 SHLD6 CLD6 SCLD6 65 65 100 65 100 200 200 35 35 65 35 65 150 150 25 25 35 25 35 100 100 LX L6 HL SL S2 CL S1 450, 500, 600 250, 300, 350, 400, 450, 500, 600 250, 300, 350, 400, 450, 500, 600 300, 400, 500, 600 300, 400, 500, 600 450, 500, 600 300, 400, 500, 600 225 6 480V AC PANELBOARDS Subfeed Breakers (available in 2-pole or 3-pole) Breaker Type FD6 , FXD6 HFD6 , HFXD6 Mounting Position When Used as Subfeed Breaker Vertical Twin Twin Interchangeable trip main breakers are mounted at the top of the panel only. mounted. Twin mounted subfeed breakers are mounted at the bottom of panelboard only and adds 24" to the panel height. Ampere Ratings For Load 70– 250 70– 250 Maximum Interrupting (kA) Symmetrical 240 Vac 480 Vac 65 35 100 65 Rating 600 Vac 22 25 Note: For detailed circuit breaker information, consult section 5. Vertically Siemens Canada Limited Power Product Catalogue 6-25 Panelboards Circuit Breaker/Lighting and Distribution Selection Type P2 Panelboards Branch Circuit Breakers Max. Amp Rating 70 PANELBOARDS 6 100 125 225 Maximum Interrupting Rating (kA) Breaker Number Type of Poles 120V AC 120/240V AC 240V AC 277V AC 480/277V AC 347V AC 600Y/347V AC Available Trip Values 1 BQD6 2 3 1 BL 2 3 1 BLH 2 3 1 HBL 2 3 BLR 2 1 BLF 2 1 BLHF 2 1 BLE 2 1 BLEH 2 BAF 1 BAFH 1 1 BQD 2 3 1 ED2 2 3 1 NGB 2 3 1 ED4 2 3 1 ED6 2 3 1 HED4 2 3 2 CED6 3 2 QJ2 3 2 QJH2 3 2 QJ2H 3 HQJ2H 3 — — — — — — — — — — — — — — — — — — — — — — — 14 — — — — — 25 — — 22 — — 25 — — 25 — — — — — — — — — — — 10 — — — — — — — — — — — — — — — — — — — — — — — — — — — — 14 — — — — — 18 — — — — — — — — — — — — — — 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 15, 20, 25, 30 15, 20, 30, 40, 50, 60 15, 20, 25, 30 15, 20, 30, 40, 50, 60 15, 20,30 15, 20, 30, 40, 50, 60 15, 20,30 15, 20, 30, 40, 50, 60 15, 20 15, 20 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 20, 25, 30, 35, 40, 45, 50 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 125 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 100, 110, 125, 150, 175, 200, 225 65 — — 10 — — 22 — — 65 — — — 10 — 22 — 10 — 22 — 10 22 65 — — 10 — — 100 — — 65 — — — — — 100 — — — — — — — — — — — — 65 — — 10 — — 22 — — 65 — — — 10 — 22 — 10 — 22 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 65 — — 10 — — 22 — — 65 10 — — — — — — — — — — — 65 65 — 10 10 — 100 100 — 65 65 — 65 65 — 100 100 200 200 10 10 22 22 42 42 100 — — — — — — — — — — — — — — — — — — — — — — — — 14 14 — — — — 25 25 — 18 18 — 25 25 42 42 200 200 — — — — — — — — 10 10 — — — — — — — — — — — — — — — — — — — — — — — — — — — 14 14 — — — — 18 18 — — — 100 100 — — — — — — — Neutral Connections Amps Main Neutral Lugs - Wire Size range Branch Neutral connections Material Wire Size range per neutral rack 125A (1) #6 - 2/0 AWG Al/Cu Standard MB Al (18) #14 - #6 AWG Al/Cu and (3) 1/0 - #6 AWG Al/Cu 250A (1) #6 - 350 MCM AWG Al/Cu Standard MLO Al (36) #14 - #4 Al/Cu and (6) 3/0 - #6 Al/Cu 400A (1) #2 - 600 MCM Al/Cu and (1) #6 - 350 MCM Al/Cu Optional Al / Cu (18) #6 - #14 AWG Al/Cu and (3) 1/0 - #14 AWG Al/Cu 600A (2) #2 - 600 MCM Al/CU and (1) #6 - 350 MCM Al/Cu 1-Pole HED4 15-30A rated 65kA 35-100A rated 25kA 1-Pole ED6 15-30A rated 30kA @ 347V 35-100A rated 18kA @ 347V CED6 breaker can be used in 400A panel with copper bussing only. Panel enclosure required is 24" (610mm) wide. 6-26 Siemens Canada Limited Power Product Catalogue NOTE: QJ Breakers are single mounted in unit space and take 6" of unit space. Limited to (4) per panel max. BL, HBL, BLH and BQD breakers are mounted in common mountings in 3" or (6) pole increments. ED2, ED4, ED6 and HED4 breakers are mounted in common mountings in 3" or (6) pole increments. Panelboards Type P2 Panelboard Kit and Accessories Selection Branch Breaker Connector Kits Kit Number Description BBKB32 BL/BQD 6-pole 3" branch breaker kit Cu/Tin BBKB32AT BL/BQD 6-pole 3" branch breaker kit Al/Tin BBKB32CS BL/BQD 6-pole 3" branch breaker kit Cu/Silver BBKCED32 CED branch breacker kit Cu/Tin BBKCED32CS CED branch breacker kit Cu/Silver BBKED32 ED 6-pole 3" branch breaker kit Cu/Tin BBKED32AT ED 6-pole 3" branch breaker kit Al/Tin BBKED32CS ED 6-pole 3" branch breaker kit Cu/Silver BBKNB32 NGB 6-pole 3" branch breaker kit Cu/Tin BBKNB32AT NGB 6-pole 3" branch breaker kit Al/Tin BBKNB32CS NGB 6-pole 3" branch breaker kit Cu/Silver BBKQ1 QJ 6-pole branch breaker kit Cu/Tin BBKQ1AT QJ 6-pole branch breaker kit Al/Tin BBKQ1CS QJ 6-pole branch breaker kit Cu/Silver Contents Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains connector kit for P2 400A, 24" wide only Kit contains breaker support, inter-phase barrier, (3) A/C connectors, (1) B connector, hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains all connectors and cover plates necessary to mount both 2 and 3-pole breakers Type P2 Miscellaneous Parts and Accessories Type P2 Spare Part Kit 12-1110-01 11-1824-01 MCHK FPLK2 DFK1 DFFP3 EGK ECGK EWK1 IGK ICGK IMK1 JCK24 NBK03 NBK04 NBK05 NBK3 NBK4 NBK5 QF3-UL P2BK1 P2BK2 P2BK3 SDKN 1 Directory card for 1-42 circuits 1 Plastic directory card holder 1 Metallic directory card holder 2 Fas-latch trim locks with 2 keys BL, BQD, ED deadfront kit for 1" (include 7 different length centre strips) 1 Filler plate 3" 1 Aluminum non-insulated ground bar 1 Copper non-insulated ground bar 1 End walls with knockouts (20"W x 5.75"D) 1 Insulated Al ground bar 1 Insulated Cu ground bar 1 Interior adjusting kit 24 Trim screws and 24 trim clips 1 Number Strip 1-42 1 Number Strip 43-84 1 Number Strip 85-126 1 Numbering Button Kit 1@42 1 Numbering Button Kit 43@84 1 Numbering Button Kit 85@126 1 Filler Plate 1" 1 P2 250A Max. Bonding Kit 1 P2 400A Max. Bonding Kit 1 P2 600A Max. Bonding Kit 1 Dripshield 20”W x 5.75”D Catalogue Number MHKP2 Description b b b b b b b b b b b b b b 8 trim screws 8 trim clips 1 bonding kit 600A max. 1 int. adjusting kit 2 Al non-insulated ground bar 2 Cu non-insulated ground bar 2 Insulated Al ground bar 2 Insulated Cu ground bar 1 Directory card 1-42 ccts 1 Directory card 43-84 ccts 1 numbering button kit 1-42 ccts 1 numbering button kit 43-84 ccts 1 Panelboard instruction book 2 plastic directory pouch Siemens Canada Limited Power Product Catalogue 6-27 PANELBOARDS Description 6 Catalogue Number Panelboards Type P2 Panelboard Factory Assembled/Modifications and Additions Enclosure Modifications Description Type 1 with gasket Type 1 with dripshield Type 3R - Waterproof and silicone free Type 3R/12 - Dustproof Type 4/4X - Standard type 304 Stainless Steel Type 4/4X - Type 316 Stainless Steel Wider enclosure - 24” wide Hinged trim Piano hinged trim Trim with padlock Door-in-door trim Screw to the box trim Trim with gasketed door Stainless steel trim b Pilot lights b Toggle switches b Push buttons (Devices mounted into a 10" minimum box extension). Painted boxes Custom colours Panel Skirts Panel Modifications (cont.) Subfeed (Double) Lugs— For Main Lug Panelboards Only Ampere Rating Type 125 Al Mechanical 250 Al Mechanical 400 Al Mechanical Feed-Thru Lugs — Cannot be used in conjonction with SPD or Subfeed Breakers (200% Neutral not available) Amp Rating Type Al Mechanical 125 Cu Mechanical Compression See page 6-47 Al Mechanical Panel Modifications 250 Service Entrance Label PANELBOARDS 6 Type P2 Panelboards are factory labeled “SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT” when identified as "Service Entrance" at the time of order entry. For regulations governing this feature, please consult CEC, CSA or local electrical authorities. Standard bussing is tin plated Al, alternate bus bar material can be selected: b Tin plated copper b Silver plated copper - optional Branch and Main Breaker Accessories Cu Mechanical Compression Al Mechanical 400 Bus Material Represented by “A”, “C” or “E” in the 11th digit of the catalogue number See section 5. b Handle blocks b Handle locks b Aux. Contacts b UVR Cu Mechanical Compression Al Mechanical Cu Mechanical 600 Compression Connector Wire Range (1) #6 AWG 2/0 AWG Al/Cu (1) #6 AWG 350 kcmil Cu (1) #6 AWG 350 kcmil Al/Cu (1) #6 AWG 350 kcmil Al/Cu (1) #6 AWG 350 kcmil Cu (1) #6 AWG 350 kcmil Al/Cu (1) #2 AWG 600 kcmil Al/Cu and (1) 1/0 AWG 250 kcmil Al/Cu (1) 1/0 AWG 600 kcmil or (2) 1/0 AWG 4/0 AWG (1) 250 kcmil 600 kcmil Cu or (2) #6 AWG 350 kcmil Al/Cu (2) #2 AWG 600 kcmil Al/Cu (2) #2 AWG 600 kcmil Cu (2) #6 AWG 350 kcmil Al/Cu (2) 400 kcmil 600 kcmil Al or (2) 400 kcmil 500 kcmil Cu Note: Ref. p.6-29 for box size additions (inches) for optional features Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. 6-28 Connector Wire Range (2) #14 AWG 2/0 AWG Al/Cu (2) #6 AWG 350 kcmil Al/Cu (2) #2 AWG 600 kcmil Al/Cu Note: Ref. p.6-29 for box size additions (inches) for optional features Mounted devices Selection Siemens Canada Limited Power Product Catalogue Contactor b Asco 920 through 225 amps – installed in an 24” auxiliary box b Siemens LEN through 200A - installed in auxiliary box: LEN 30A-60A = Min. 5¾”D x 20”W x 10”H LEN 100A = Min. 5¾”D x 20”W x 18”H LEN 200A = Min. 7¾”D x 20”W x 24”H Increase Capacity Neutral up to 200% (N/A on Feed Thru Lugs & Subfeed Lugs) Main Bus Amps 125 250 400 600 See page 6-29 for unit space adders and compatibility with other options. Grounding of Panelboards Ground Bars are shipped with the panel interior factory mounted. b b b b Non-Insulated Equipment Ground Bar Copper Non-Insulated Ground Bar Al Insulated Equipment Ground Bar Cu Insulated Equipment Ground Bar Shunt Trip on Main or Branch BL, BLH, HBL, NGB, ED4, HED4, HED6, uses 1” unit space for shunt trip. All others may be used on mains or subfeeds. Surge Protective Device see section 9 b TPS3 01 - Bus connected - Internally mounted (30A breaker required to feed SPD) - Externally mounted in a 15" high aux. enclosure (30A breaker required to feed SPD) b TPS3 09 - Internally mounted (20A breaker required to feed SPD) - Externally mounted (20A breaker required to feed SPD) b TPS3 12 - Externally mounted (40A breaker required to feed SPD) Panelboards Type P2 Panelboard Standard Modifications and Additions Selection Box Size Additions for Optional Features - Inches (mm) Main Lugs Main Breakers 125A 250A 400A 600A 26 (660) 0 32 (813) 0 38 38 (965) (965) 6 (all) 6 (all) (152) (152) 0 0 0 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) 12 (305) 6 (152) 12 (305) 24 (610) 6 (152) 6 (152) 12 (305) 12 (305) 12 (305) 6 (152) 12 (305) 24 (610) 12 (305) 12 (305) Options *Min. Box Size 200% Neutral (lug type) Std. Lugs (100% Neut. PNL) CU Lugs (100% Neut. PNL) Comp Lugs (100% Neut. PNL) Feed-thru Standard Lugs Feed-thru Cu Lugs Feed-thru Comp Lugs Subfeed Standard Lugs (1) FD Subfeed (Horizontal Mtg.) (2) FD Subfeed (Vertical Mtg.) 0 N/A N/A 12 (305) SPD 125A 125A Horiz. Horiz. BL, BQD, ED, NGB CED 125A Vert. 225A Horiz. 225A Vert. 225A Horiz. 250A Vert. 250A Vert. 400A JD 400A CJD 50 (1270) 62 (1575) 600A LD 600A CLD ED QJ QJ FD FD CFD 26 (660) 32 (813) 32 (813) 32 (813) 38 (965) 38 (965) 44 (1118) 50 (1270) 0 0 0 N/A 0 N/A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N/A N/A 0 N/A 0 N/A 0 0 0 0 0 0 N/A 0 N/A 0 0 0 0 0 0 6 (152) 6 (152) 12 (305) 6 (152) 6 (152) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) N/A N/A N/A N/A 6 (152) 12 (305) N/A N/A 0 6 (152) 6 (152) N/A N/A N/A N/A N/A N/A 6 (152) 6 (152) 6 (152) N/A N/A N/A N/A N/A N/A N/A 12 (305) 12 (305) 24 (610) 12 (305) 56 62 (1422) (1575) 6 (152) 6 (152) 6 (152) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 12 (305) 24 (610) 12 (305) N/A 12 (305) 24 (610) 12 (305) N/A 12 (305) 24 (610) 12 (305) N/A 12 (305) 24 (610) N/A N/A N/A 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) N/A N/A N/A N/A N/A 6 NOTE: N/A = OPTION NOT AVAILABLE *Min. Box Size, corresponding to 9" of Unit Space. Style MLO Main Breaker Compression Connector Wire Range Amp Rating Breaker Type 125 250 N/A N/A 400 N/A 600 N/A 100 ED2, ED4, ED6, HED4, CED6 250 FXD6, HFD6, CFD6 (1) 350 kcmil Al/Cu 400 600 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 LD6, LXD6, HLD6, CLD6, SLD6, SHLD6, SCLD6 (1) 500 kcmil Al/Cu (1) 500 kcmil Al/Cu (1) (1) (1) (2) (2) (2) (2) #6 AWG - 350 kcmil Al/Cu #6 AWG - 350 kcmil Al/Cu 250 - 600 kcmil Cu #6 AWG - 350 kcmil Al/Cu #6 AWG - 350 kcmil Al/Cu 400 - 600 kcmil Al or 400 - 500 kcmil Cu (1) 2/0 AWG Al/Cu PANELBOARDS Compression Lugs Box Height Addition - Inches (mm) 6 (152) 6 (152) 6 (152) 6 (152) Box must go to 24" wide on CED6 breaker only Add 6" to box height for NØ Box must go to 24" wide for all breakers Requires an additional 6.0" box height 9 (229) 6 (152) NOTE: Standard compression lugs used for P2 are range taking lugs and may require a particular crimping tool to accommodate the range. Consult factory for information. Alternate Lugs Amp Rating Breaker Type MLO 400 N/A Main Breaker 400 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 Style Alternate Connector Wire Range (1) 250 - 750 kcmil Al/Cu or (2) #3/0 AWG - 250 kcmil Al/Cu (1) #4/0 AWG - 750 kcmil Al/Cu Box Height Addition - Inches (mm) 6 (152) 6 (152) Not availabe for feed thru lug. Siemens Canada Limited Power Product Catalogue 6-29 Panelboards Type P2 Panelboard Kits and Accessories Standard Enclosures Catalogue Number Box Height Inches (mm) Type 1 Standard Box Surface Trim Flush Trim Type 3R/12 26 (660) B26 S26B F26B WP26 32 (813) B32 S32B F32B WP32 38 (965) B38 S38B F38B WP38 44 (1118) B44 S44B F44B WP44 50 (1270) B50 S50B F50B WP50 56 (1422) B56 S56B F56B WP56 62 (1575) B62 S62B F62B WP62 68 (1727) B68 S68B F68B WP68 74 (1880) B74 S74B F74B WP74 PANELBOARDS 6 Options For Type 1 Trims Hinged trim – Replace “B” suffix with “H” Door-in-door – Replace “B” suffix with “D” Screw to box – Replace "B" suffix with "C" Trim with padlock – Add "–PL" suffix Metal card holder – Add "M" suffix on all trims Option For 24" Wide Enclosures 24” wide with equal gutter on both sides - Add “24” as prefix Flush trim extend 3/4" on each side of the base box. 6-30 Hinged door included in type 3R/12 enclosures. Siemens Canada Limited Power Product Catalogue Selection Panelboards Type P2 Panelboards Dimensions Type 1 Box Box is symmetrical 6 PANELBOARDS Type 3R and 3R/12 Box Dimensions are interior of the box. Add 5/8"[16mm] to width for absolute dimension. Add 1/8"[3mm] to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens Canada Limited Power Product Catalogue 6-31 Panelboards Type P3 Panelboards Features Another innovation from Siemens is the P3 panel. It is a smaller, footprint distribution panel to fit a number of applications. This panel offers factoryassembled options, and has the ability to mix breaker frames in unit space up to 125 amps. Bussing options for the P3 are aluminum and copper. All bussing in the P3 panel is tin-plated as a standard. Silver-plated copper is offered as an option. PANELBOARDS 6 The P3 panel configurations, defined by the unit space, allow for a given amperage and box height. The P3 panel starts with a 56" high box. Breaker unit space can be mixed and matched to meet customer requirements. All 1" pole breakers (BL, BQD, ED frames) are mounted in 3" or 6" pole increments. Like other distribution panels, the P3 panel can have blank space added into the panel to allow for future expansions or modifications. Any expansions or modifications must be in 3" increments. BL, BQD and ED frame breakers have 3" or 6-pole kits and can be mixed in unit space by these increments. Breakers of the same frame can cross from one mounting to another if contiguous. 6-32 General Voltage – 600V AC max. 250V DC max. Amperage – 800 amp max. Short circuit rating 200,000 A @ 480 Vac / 100,000 A @ 600 Vac IR Maximum symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to 22 KAIC or the lowest rated device installed unless a series combination rating for a remote main is indicated. Note that the main device may be mounted remote from the panel. Panelboards cUL and UL listed, under “Panelboards” File #E2269 for the interiors and #E4016 for boxes and fronts Enclosure – Standard Type 1 enclosure is 24" wide x 7.75" deep x Box Height is determined by main device and unit space. See charts for box height. Panelboards Fronts and Doors Standard panelboards are furnished with trim featuring concealed fasteners and hinges with a flush door lock. All are factory assembled for ease of installation. Trims are fabricated from code gauge steel and finished ANSI-61. See page 6-6 for optional trims. Siemens Canada Limited Power Product Catalogue Branch Breaker Side Gutter Wiring Space - Inches (mm) Reference Letter Panel Width 24” (610) A B C D E 7.750 (197) 7.125 (181) 6.000 (152) 6.625 (168) 5.750 (144) Branch Breaker Wire Bending Diagram A BL, BLH, HBL BLF, BLFH BL, BLH, HBL B BQD, BQD6 BQD, BQD6 C A BLF, BLFH B ED2, ED4, ED6 ED2, ED4, ED6 HED4 HED4 C D NGB NGB D E NEB, HEB NEB, HEB E Panel Width 24 in. (610 mm) Weight – Approximate Total panelboard weight when filled accessories is: b About 5 lbs. (1kg) per inch of box height Gauge Steel of Boxes and Fronts, Surface & Flush Dimensions - Inches (mm) Gauge Steel Width Height Box Front 24 (610) 56-80 (1422-2032) #14 #14 Panelboards Type P3 Panelboards Selection/Dimensions Panel Unit Space to Box Height Requirements Box Height Inches (mm) “B” dimension 56 62 68 74 80 (1425) (1575) (1727) (1880) (2032) Main Lug Wire Bending Diagram P2 Panels, with standard Line lugs unit space (starting with 9” and adding 6” increments) “A” dimension Main Lugs 400A 600A 800A 21 27 33 39 45 21 27 33 39 45 21 27 33 39 45 Main Lug Wire Bending - Inches (mm) Panel Amps Standard Connectors C D 400 (1) #2 - 600 kcmil Al/Cu and (1) 1/0 - 250 kcmil Al/cu 16.00 (406) 17.88 (454) 600 (2) #2 - 600 kcmil Al/Cu 16.00 (406) 17.88 (454) 800 (2) #2 - 600 kcmil Al/Cu 16.00 (406) 17.88 (454) 400A Neutral Connections No. of circuits Neutral Lug Wire Size range 42 circuits Box depth = 7.75 in. (197 mm) Box width = 24 in. (610 mm) (16) #4 - #14 AWG (15) 1/0 - #14 AWG 54 circuits 66 circuits No. of connections per neutral bar (1) #2 - 600 kcmil Al/Cu (23) #4 - #14 AWG (22) 1/0 - #14 AWG 78 circuits 90 circuits 600A - 800A Neutral Connections Neutral Lug Wire Size range 42 circuits 78 circuits PANELBOARDS (16) #4 - #14 AWG (15) 1/0 - #14 AWG 54 circuits 66 circuits No. of connections per neutral bar 6 No. of circuits (2) #2 - 600 kcmil Al/Cu (23) #4 - #14 AWG (22) 1/0 - #14 AWG 90 circuits Siemens Canada Limited Power Product Catalogue 6-33 Panelboards Circuit Breaker/Lighting and Distribution Selection/Dimensions Type P3 Panelboards Branch Circuit Breakers Bolt-On Breaker Type Amps 277V AC 480V AC 600V AC 250V DC 70 BQD6 15-70 — 65 65 — — 10 14 BL 15–60 70 80–100 10 — — — 10 — — — 10 — — — — — — — — — — — — BLH 15–60 70 80–100 — — — 22 22 — — — 22 — — — — — — — — — — — — HBL 15–55 60–100 — — 65 — — 65 — — — — — — — — BLE (GFCI) 15–30 40–60 10 — — 10 — — — — — — — — — — BLEH (GFCI) 15–30 15–60 22 — — 22 — — — — — — — — — — BLF (GFCI) 15–30 40–60 10 — — 10 — — — — — — — — — — BLHF (GFCI) 15–30 40–60 22 — — 22 — — — — — — — — — — — 120V AC 120/240V AC 240V AC BAF 15–20 10 — — — — — BAFH 15–20 22 — — — — — — BQD 15–60 70–100 — — 65 — — 65 — — 14 14 — — 14 14 ED2 15–60 70–100 — — — — 100 100 42 42 42 42 — — 30 30 NGB 15–60 70–100 110–125 100 100 100 100 100 100 100 100 100 25 25 25 25 25 25 — — — 14 14 14 NEB 15–60 70–100 110–125 85 85 85 85 85 85 85 85 85 35 35 35 35 35 35 22 22 22 35 35 35 HEB 15–60 70–100 110–125 100 100 100 100 100 100 100 100 100 65 65 65 65 65 65 25 25 25 42 42 42 ED4 15–60 70–100 110–125 65 — — — — — — 65 65 22 — — — 18 18 — — — — 30 — ED6 15–60 70–100 110–125 — — 100 — — — 65 65 — — — — 25 25 — 18 18 — 30 — — HED4 15–60 70–100 110–125 100 — — — — — — — — — 65 65 — — — — — — — — — 6 100 PANELBOARDS Provisions for Maximum Interrupting Rating (kA) Max. Amp Rating 125 Branch Breaker Connector Kits Kit Number BBKB32 Description BL/BQD 6-pole 3" branch breaker kit Cu/Tin BBKEB32 NEB/HEB branch breaker kit Cu/Tin BBKED32 ED 6-pole 3" branch breaker kit Cu/Tin BBKNB32 NGB 6-pole 3" branch breaker kit Cu/Tin Note: BL, HLB, BLH and BDQ are mounted in common mountings in 3" or (6) pole increments. ED2, ED4, ED6 and HED4, breakers are mounted in common mountings in 3" or (6) pole increments. 6-34 Siemens Canada Limited Power Product Catalogue Contents Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains breaker support, inter-phase barrier, (3) A/C connectors, (1) B connector, hardware Kit contains breaker support, inter-phase barrier, (3) A/C connectors, (1) B connector, hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Panelboards Type P3 Panelboard Factory Assembled/Modifications and Additions Enclosure Modifications Description Type Type Type Type 1 with gasket 1 with dripshield 3R/12 - Dustproof 4/4X - Standard type 304 Stainless Steel Hinged trim Door-in-door trim Screw to the box trim Trim with gasketed door Stainless steel trim Panel Modifications (cont.) Subfeed (Double) Lugs For Main Lug Panelboards Only Ampere Rating Connector Cu /Al Wire Range 400 (2) #2 - 600 kcmil Al/Cu Feed-Thru Lugs — Cannot Be Used in Conjonction with SPD. See page 6-36 for unit space adders and compatibility with other options Painted boxes Custom colours Panel Skirts Selection See page 6-47 Ampere Rating 400 Panel Modifications Bus Material Represented by “A”, “C” or “E” in the 11th digit of the catalogue number Standard bussing is tin plated Al, alternate bus bar material can be selected: b Tin plated copper b Silver plated copper - optional Branch Breaker Accessories Grounding of Panelboards Ground Bars are shipped with the panel interior factory mounted. b b b b Non-Insulated Equipment Ground Bar Copper Non-Insulated Ground Bar Al Insulated Equipment Ground Bar Cu Insulated Equipment Ground Bar Shunt Trip on Branch BL, BLH, HBL, NGB, ED2, ED4, HED4, ED6, uses 1” unit space for shunt trip. Surge Protective Devices 6 See section 5. b Handle blocks b Handle locks b Aux. Contacts b UVR 600 800 Connector Cu /Al Wire Range (1) #2 - 600 kcmil Al/Cu and (1) 1/0 - 250 kcmil Al/Cu (2) #2 - 600 kcmil Al/Cu (2) #2 - 600 kcmil Al/Cu See section 9 PANELBOARDS b TPS3 01 - Bus connected -Internally mounted (30A breaker required to feed SPD) -Externally mounted in a 15” high aux. enclosure (30A breaker required to feed SPD) b TPS3 09 - Internally mounted (20A breaker required to feed SPD) - Externally mounted (20A breaker required to feed SPD) b TPS3 12 (Sold separately) - Externally mounted (40A breaker required to feed SPD) Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. Siemens Canada Limited Power Product Catalogue 6-35 Panelboards Type P3 Panelboard Standard Modifications Selection Option Combinations Amps Incoming Subfeed Lugs Feed-thru Lugs 200% Neutral Min. Box Size - Inches (mm) Unit Space - Inches (mm) 400 Main Lug Only • — — • • • 56 (1422) 56 (1422) 21 (533) 15 (381) 600 Main Lug Only — — • • — 56 (1422) 56 (1422) 21 (533) 15 (381) 800 Main Lug Only — — • • — 56 (1422) 56 (1422) 21 (533) 9 (229) • Available as an option Compression Lugs Style MLO Amp Rating Breaker Type Compression Connectors Box Height Addition 400 N/A (1) 250 - 600 kcmil Cu — 600 N/A (1) 400 - 500 kcmil Al or (1) 400 - 600 kcmil Cu — — 800 N/A (2) 250 - 600 kcmil Cu — NOTE: Standard compression lugs are range taking lugs and may require a particular crimping tool to accommodate the range. Consult factory for information. Alternate Lugs Style Amp Rating Breaker Type Standard AL Connectors Box Height Addition Inches (mm) 400 N/A (1) 250 - 750 kcmil or (2) #3/0 AWG - 250 kcmil Al/Cu 6 (152) 800 N/A (4) #4 - 500 kcmil Al/Cu 6 (152) PANELBOARDS 6 MLO Type P3 Miscellaneous Parts and Accessories Catalogue Number Description 12-1110-01 1 Directory card for 1-42 circuits 11-1824-01 1 Plastic directory card holder MCHK 1 Metallic directory card holder FPLK2 2 Spare Fas-latch trim locks with 2 keys DFK1 BL, BQD, ED deadfront kit for 1" (include 7 different length centre strips) DFFP3 1 Filler plate 3" EGK 1 Aluminum non-insulated ground bar ECGK 1 Copper non-insulated ground bar EWK2 1 End wall with knockouts (24”W x 7.75”D) IGK 1 Insulated Al ground bar ICGK 1 Insulated Cu ground bar IMK1 1 Interior adjusting kit JCK24 24 Trim screws and 24 trim clips NBK03 1 Number Strip 1-42 NBK04 1 Number Strip 43-84 NBK05 1 Number Strip 85-126 NBK3 1 Numbering Button Kit 1@42 NBK4 1 Numbering Button Kit 43@84 NBK5 1 Numbering Button Kit 85@126 QF3-UL 1 Filler Plate 1” DSK724 1 Dripshield 24”W x 7.75”D 6-36 Siemens Canada Limited Power Product Catalogue Panelboards Type P3 Panelboards Dimensions Type 1 Box Box is symmetrical 6 Type 3R and 3R/12 Box PANELBOARDS Dimensions are interior of the box. Add 5/8" [16mm] to width for absolute dimension. Add 1/8" [3mm] to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens Canada Limited Power Product Catalogue 6-37 Panelboards Power and Disribution Selection Type S5 (SPP6) Main Lug Connectors 600 Volts AC, 250 Volts DC Maximum 1200 Ampere Mains 1200 Ampere Maximum Branch UL & CSA Short Circuit Rating — 200,000A IR Maximum Ampere Rating Branch Breaker Symmetrical Interrupting Capacity Based on Underwriters’ Test Procedure 6 (1)–#3/0 AWG-500MCM 400 (2)–#3/0 AWG-250MCM 600 (2)–#3/0 AWG-500MCM 800 (3)–#3/0 AWG-500MCM 1200 (4)–#3/0 AWG-500MCM End Gutters Meets 1996 NEC wire bending requirement, section 373-6. CSA - C22.2 No. 0.12 PANELBOARDS Connectors Suitable for Cu or Al 400 Ampere Rating Main Lug (inches) Main Breaker (inches) 400/600 15.967 13.0 800/1200 15.967 13.0 Panelboards Listed by Underwriters’ Laboratories, Inc., under “Panelboards” File #E2269 for interiors and #E4016 for boxes and fronts. Meet Federal Specification W-C375B/Gen. & CSA File #LR93833. Boxes 38” wide, 12.75” deep (Type 1) 38” wide, 14.25” deep (Type 3R/12) Service 600 Volts AC, 250 Volts DC, Maximum. 1 Phase, 3 Wire; 3 Phase, 3 Wire; or or 3 Phase, 4 Wire. Panelboard Specifications Panelboard Fronts and Doors Standard panelboards are furnished with 4 piece trim with ventilation. Fronts are fabricated from code gauge steel and finished ASA61. Maximum Unit Panel Space Ampere (MLO) Integrated Equipment Short Circuit Ratings The term “Integrated Equipment Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL & CSA. Series ratings must be specified on order at time of entry. Box Height 400A 30” 60” 120/240Volts 120/208 Volts 600 Volts 347/600 Volts 600A 800A 1200A 45” 60” 60” 75” 90” 90” 1 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire Main Breakers All 400A and 1200A frame main breakers are mounted horizontally. Branch Breaker Side Gutters ———A ——— ———B——— ———C——— ———D——— ——E—— ——— F ——— ———— G ———— —— H—— —I— —J— —K— —M— 6-38 BL BLH, HBL, BQD6, NGB ED4, ED6 HED4 QJ2, QJH2 QJ2H FXD6, FD6 HFD6 JXD6, JD6 HJD6 BL BLH, HBL, ED4, ED6 HED4 QJ2, QJH2 QJ2H FXD6, FD6, HFD6 JXD6, JD6 HJD6 Panel Width (inches) Reference Letter 38 (S5) A 14.0 B 10.0 C 8.75 D 8.25 E 7.925 F 7.615 G 11.769 H 13.425 CFD6 I 8.956 JXD6, JD6, LXD6, LD6, SLD6 HJD6, SJD6, HLD6 J 13.0 K 12.0 CJD6, CLD6 M 13.0 CED6 CED6 MD6, ND6, CMD6, CND6, HMD6, HND6 SMD6, SND6 LMD6, HLMD6 Siemens Canada Limited Power Product Catalogue Panelboards Power and Disribution Selection Main Breaker Selection Ampere Rating 400 600 800 1200 Breaker Type JXD6 JD6 HJD6 CJD6 SJD6 LXD6 LD6 HLD6 CLD6 SLD6 MD6 HMD6 CMD6 SMD6 ND6 HND6 CND6 SND6 Maximum Interrupting Rating (KA) 240V 65 65 100 200 65 65 65 100 200 65 65 100 200 65 65 100 200 65 480V 35 35 65 150 35 35 35 65 150 35 50 65 100 50 50 65 100 50 600V 25 20 35 100 25 25 25 35 100 25 25 50 65 25 25 50 65 25 Available Trip Values 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 300, 400 450, 500, 600 250, 300, 350, 400, 450, 500, 600 250, 300, 350, 400, 450, 500, 600 450, 500, 600 300, 400, 500, 600 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 600, 700, 800 800, 900, 1000, 1200 800, 900, 1000, 1200 900, 1000, 1200 900, 1000, 1200 Branch Circuit Breaker Selection Breaker Type BL BLF (GFCI) BLE (GFCI) BLH BLH (GFCI) BQD6 ED2 ED4 ED6 Max IC Rating (KA) 240V 480V 600V 10 — — 10 — — 10 — — 22 — — 22 — — 65 — 10 10 — — 65 18 — 100 18 18 100 42 18 200 200 100 — 100 10 — — 22 — — 42 — — 65 35 — 100 65 — 200 200 — 65 — — 65 35 25 100 65 35 200 150 100 65 35 25 100 65 35 200 150 100 65 35 25 100 65 35 200 150 100 65 35 25 100 65 35 200 150 100 65 50 25 100 65 50 65 35 25 100 65 35 200 150 100 65 35 25 100 65 50 200 100 65 65 50 25 100 65 35 200 150 100 65 35 25 100 65 50 200 100 65 100 — — 85 35 22 100 65 25 65 35 18 200 100 25 65 35 18 200 100 25 65 35 25 14.0” (356) A A B B C C 5.00” (127) D D 5.00” (127) E E 8.75” (222) F F 3.75” (95) 3.75” (95) 3.75” (95) 10.0” (254) 8.75” (222) 8.25” (210) 7.925” (201) 7.615” (193) G 5.00” (127) 11.769” (299) H 8.75” (222) 13.425” (341) I 8.75” (222) 8.956” (227) 13.0” (330) 12.0” (305) 13.0” (330) J K M 10.00” (254) 10.00” (254) 8.75” (222) Space includes housing frame plate with blank cover plate. Provision includes all necessary mounting hardware, less circuit breaker, and includes housing frame cover plate with breaker handle opening. 1 to 6 poles may be mounted in 3.75” (95) of unit space Accessories such as shunt trips on three pole breakers require 6.25” (159) of unit space. Ground fault is not available on branch Sensitrip breakers. Also 10KA at 600Y/347 Volts. Refer to Table 5 for layout dimensions. Siemens Canada Limited Power Product Catalogue 6-39 PANELBOARDS QJ2 QJH2 QJ2-H FXD6 HFD6 CFD6 JXD2 JXD6, JD6 HJD6 CJD6 SJD6 SHJD6 SCJD6 LXD6, LD6 HLD6 CLD6 SLD6 SHLD6 SCLD6 LMD6 HLMD6 MD6 HMD6 CMD6 SMD6 SHMD6 SCMD6 ND6 HND6 CND6 SND6 SHND6 SCND6 NGB NEB HEB NDG LDG NFG LFG NJG Mounting Height Inches (mm) Twin Single Gutter 3.75" (95) — A 3.75" (95) — A 3.75" (95) — A 3.75" (95) — A 3.75" (95) — A 3.75" (95) — A 3.75" (95) 3.75" (95) B 3.75" (95) 3.75" (95) B 3.75" (95) 3.75" (95) B 3.75" (95) 3.75" (95) B 3.75" (95) 3.75" (95) F 3.75" (95) F — 5" (127) 5" (127) C 5" (127) 5" (127) C 5" (127) 5" (127) C 5" (127) 5" (127) D 5" (127) 5" (127) D — 5" (127) G 8.75" (222) 8.75" (222) E 8.75" (222) 8.75" (222) E 8.75" (222) 8.75" (222) E — 8.75" (222) I — 8.75" (222) H — 8.75" (222) H — 8.75" (222) I 8.75" (222) H — — 8.75" (222) H — 8.75" (222) I — 8.75" (222) H — 8.75" (222) H — 8.75" (222) I 8.75” (222) M — — 8.75” (222) M 10” (254) J — — 10” (254) J — 10” (254) J — 10” (254) K — 8.75" (222) H — 8.75" (222) I 10” (254) J — — 10” (254) J — 10” (254) J — 10” (254) K — 8.75" (222) H — 8.75" (222) I 3.75" (95) — — 3.75" (95) — — 3.75" (95) — — 5" (127) — — 5" (127) — — 5" (127) — — 5" (127) — — 6.25" (159) 6.25" (159) — 6 CED6 Available Trip Value Ampere Ratings 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 15, 20, 30, 40, 50, 60 15, 20, 30 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 15, 20, 30, 40, 50, 60 15, 20, 30, 40, 50, 60, 70 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 30, 40, 50, 60 70, 80, 90, 100, 110, 125 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 110, 125 — 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 70, 80, 90, 100, 125, 150, 175, 200, 225, 250 70, 80, 90, 100, 125, 150, 175, 200, 225, 250 70, 80, 90, 100, 125, 150, 175, 200, 225, 250 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 300, 400 200, 300, 400 200, 300, 400 450, 500, 600 250, 300, 350, 400, 450, 500, 600 450, 500, 600 300, 400, 500, 600 300, 400, 500, 600 300, 400, 500, 600 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 600, 700, 800 600, 700, 800 500, 600, 800 800, 900, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 800, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 125 50, 60, 70, 80, 90, 100, 110, 125, 150 50, 60, 70, 80, 90, 100, 110, 125, 150 100, 110, 125, 150, 175, 200, 225 100, 110, 125, 150, 175, 200, 225 250, 300, 350, 400 Branch Breaker Gutter Dimensions For 38”W Distribution Section Panelboards Modifications and Additions Type S5 When required, special constructions or additions to standard panelboards may be specified for all factoryassembled Power and Distribution Panelboards. Below and on the next page are listed many of those available for Type S5 panelboards. In no case do these apply to Narrow (Column) Width Lighting Panelboards or Unassembled Panelboards. 1. Miscellaneous NEMA TYPE Type1 Type 2 (Drip-proof) . . . . . . . . . . . . . . Type 3R Type 12 2. Painted Finish Touch-Up Paint (ASA61, Light Gray) 12 oz. aerosol can, Catalog Number TUP61 3. Miscellaneous Accessories PANELBOARDS 6 Nameplate — laminated, engraved Tamper-Resistant Screws 4. Devices Mounted on Gutter Cover — Includes Device, Mounting — Wired or Unwired Toggle Switch — SPST or 3-way; 15A Pilot Light — General Purpose, Neon or Incandescent Selection 6. MLO Compression Lugs — Available as main lugs and neutral lug. 400 600 800 1200 Consult Sales Office 5 5 5 5 Consult Sales Office 7. Grounding of Panelboards Non-Insulated Equipment Ground Bus Including Ground Lug Insulated Equipment Ground Bus Including Ground Lug 8. Remote Control Switches ASCO 920 600V AC Mechanically Ampere Held Rating 2-Pole 3-Pole 30 60 75 100 150 200 225 Siemens CLH Electrically Held 2-Pole Unit space 20” 3-Pole Unit space 20” 9. Increased Capacity Neutral Ampere Rating Phase Neutral 400 400 600 800 600 800 1200 1200 Unit Space (inches) None None None None Lugs Ampere Rating 400 600 800 1200 BL, BLH, HBL, BQD6,QJ2, QJH2, QJ2-H, NGB Deduct From Available Unit Ampere Aluminum Copper Space Rating (Specify Size ) (Specify Size) (inches) Pushbutton 5. Feed-Thru (One Set Per Panel) Padlocking Device — Padlocks in “OFF” position. Available for: ED4, ED6, HED4, CED6 FXD6, FD6, HFD6, CFD6 JXD6, JD6, HJD6, CJD6, SJD6, LXD6, LD6, HLD6, CLD6, SLD6 MD6, HMD6, CMD6, SMD6, ND6, HND6, CND6, SND6 11. Ground Fault Sensing Relay Kit Equipment Protection (30 ma) For Use with Number of Breaker Types Poles ED4, ED6, HED4 1, 2, 3 Description Basic kit Basic kit with bell alarm 12. Main Bus Standard main bus and ground bus are tin plated aluminum. For copper main bus, neutral bus and ground bus change prefix ‘A’ to ‘C’ on catalog number and contact your sales office for pricing. 13. Copper Lugs — For Main Lug Only Panels Standard main lugs and neutral lugs are tin plated aluminum, UL & CSA listed for use with aluminum/copper cables. For copper lugs in the mains and neutral for use with copper cables only, contact sales. 14. Shunt Trip on Main and Branches Description BL, BQD6, NGB (branch only) 10. Circuit Breaker Accessories Unit Space (Additional inches) 3-Pole 2-Pole MLO Consult Sales 10 Consult 10 Sales 17.5 17.5 Breaker Type Handle Blocking Device Blocks handle in either the “ON” or “OFF” position. Available for: BL, BLH, HBL, BQD6, QJ2, QJH2, QJ2-H, NGB ED4, ED6, HED4, CED6 FXD6, FD6, HFD6, CFD6 JXD6, JD6, HJD6, CJD6, SJD6, LXD6, LD6, HLD6, CLD6, SLD6 QJ2, QJ2H, QJH2, ED2, ED4, HED4 (branch only) All others through 600A 800A and 1200A 15. Sentron TPS (TVSS Modules) 160 KA 240 KA Options Surge Counter Remote Indicator MD6, HMD6, CMD6, SMD6, ND6, HND6, CND6, SND6 For use on main lug, main breaker or main switch panels without subfeed breakers. increase in panelboard height — Consult local sales office. Ground bar not installed in box. For short circuit ratings with remote control switches, consult sales office. For 6-40 Available in 90” high enclosure only. Unit space is 42 1/2” with Test and Monitor Panel; 45” without Test and Monitor Panel. Not available on Sensitrip III. For required unit space — consult local sales office. Price does not include control power transformer. Siemens Canada Limited Power Product Catalogue Price 600 Volt 71⁄2” high units. Mounting height increases to 6.25” when shunt trip is required. Shunt Trip on 100A frame breakers increases mounting height to 6.25” for twin mounting. Not CSA approved. Panelboards Modifications and Additions Replacements for Circuit Breakers Selection Replacement Connecting Strap Guide The following table may be used to obtain the proper connector kit by measuring the exterior dimensions of the panel. Every attempt has been made to make this table complete and accurate. The table is based on panels produced by ITE, Bulldog and Siemens from 1958 to present. Should any questions arise please contact your Siemens sales office for replacements. Panel Type OLD CDP Replacement Max Amps 400 9.75” OLD CDP 600 32” - 38” 38” For use with Series 6 CDP Panelboards, S5, F2, FCI and FCII Switchboards. Height SPP/FPP/CDP/VB 6 1.25” 6FPB01 2.50” 6FPB02 Note MCCB only. 3.75” 6FPB03 5.00” 6FPB05 MCCB only. 10.00” 6FPB10 15.00” 6FPB15 Panelboard Tub Width Depth 9” 30” - 36” - 42” Blank Plates 13.75” CDP/VB6 1200A 600A MCCB series 6 connectors “VB” style units only (*) 12.75” SPP/FPP6 1200A 600A MCCB series 6 connectors “VK” or “VB” style (*) Connecting Strap Kits and FrontFiller Plates For use with NDP-CDP-7, S3 * If switch unit width is 17” it is a vacubreak. If switch unit width is 23” or 28” it is a “VK” switch. Connecting Strap For Use With SPP/FPP, S5, F2 Breakers Catalogue Number Height Inches (mm) Series 6 Number BQD6 (S3 only) 7 BQD6-2 Breakers BL, BLH, HBL, 7 BL-2 BQ, BQH, HB 3.75” (95) 6EQ6 QJ2, QJH2, 2 Pole 7 QJ2-1 BL, BLH, HBL, BQD, BQD6 3.75” (95) 6BL2C 7 QJ3-1 QF3-UL ED2, ED4, ED6, HED4 3.75” (95) 6E62 CED6 3.75” (95) 6CLE2 QJ2, QJH2, QJ2H 5” (127). 6QJ2 FXD6, FD6, HFD6 5” (127) 6F62 QJ2, QJH2 3 Pole Single unit, Panel Mount QJ2, QJH2 3 Pole Double unit, Panel Mount EC4, ED2, ED4, ED6, HED4, HED6 CFD6 5” (127) 6CLF1C Filler 1 Pole JXD2, JXD6, JD2, JD6, HJD6 8.75” (222) 6JJ62 7 QJ3-2 7 E6-2 6CLJ1C 8.75” (222) 6LL61C CLD6 8.75” (222) 6CLL1C SCLD6 8.75” (222) 6SCL61C MD6, HMD6, CMD6, SCMD6, SHMD6 10” (254) 6M61C ND6, HND6, CND6 SND6, SHND6, SCND 10”(254) 6N61C PANELBOARDS 8.75” (222) 6 CJD6, SCJD6 LXD6, LD6, HLD6, SLD6, SHLD6, Connecting Strap Kits For Use With Circuit Breakers in S5 Breaker Type Hieght Inches (mm) Mounting Catalogue Number SNBD NGB 3.75” (95) D NEB, HEB 3.75” (95) D SEBD 5” (127) D SDGD NDG, HDG, LDG NFG, HFG, LFG 5” (127) D SFGD NJG, HJG, LJG 6.25” (159) D SJG2D NJG, HJG, LJG 6.25” (159) S SJG1D These are aluminum connectors. If copper required is please add suffix C. 3.75” (95) plate accommodates six 1-pole breakers. 10” (254) plate accommodates eighteen 1-pole breakers. These connectors are available in copper only. Can be used as fillers or in place of circuit breakers, VK or VB Switches. Siemens Canada Limited Power Product Catalogue 6-41 Panelboards Fusible/Power and Distribution Selection Type F2 Ampere Rating Panelboards Listed by Underwriters’ Laboratories, Inc., under “Panelboards” File #E2269 fo interiors and #E4016 for boxes and fronts & CSA File #LR93833. Ampere Rating Connectors Suitable for Cu or Al 400 (1) - 750 MCM OR (2) - 250 MCM (Cu or Al) 600 (2) - 750 MCM OR (4) - 250 MCM (Cu or Al) 600 800 (3)—#3/0 AWG–500 mcm 800 (3)—#3/0 AWG–500 mcm 1200 (4)—#3/0 AWG–500 mcm 1200 (4)—#3/0 AWG–500 mcm 400 Wire and Cable Range 30 60 100 (1)—#14–#2 AWG (Cu or Al) (1)—#14–#2 AWG (Cu or Al) (1)—#14–#1/0 AWG (Cu or Al) 400 600 (1)—#3/0 AWG–500 mcm (2)—#3/0 AWG–250 mcm (2)—#3/0 AWG–500 mcm Gutters Switch Ampere Rating 200 Boxes 38” wide, 12.75” deep, Type 1 End Gutters (Minimum inches) Side Gutters (Minimum inches) 400 12 7.9 600 12 7.9 800 12 7.9 1200 12 7.9 Ampere Rating (1)—#6 AWG–350 kcmil (Cu or Al) (1) - 750 MCM OR (2) - 250 MCM (Cu or Al) (2) - 750 MCM OR (4) - 250 MCM (Cu or Al) Maximum VB HP Ratings Panelboard Fronts and Doors Standard panelboards are furnished with 4 piece trim. Fronts are fabricated from code gauge steel and finished ASA61. 6 Connectors Suitable for Cu or Al Branch Switch Connectors Service 600 Volts AC, 250 Volts DC, Maximum. 1 Phase, 3 Wire; 3 Phase, 3 Wire; or 3 Phase, 4 Wire. PANELBOARDS Main Lug Panels Main Switch Panel Connectors 600 Volts AC, 250 Volts DC Maximum 600 Ampere Main Switch, 1200 Ampere Main Lugs Only 600 Ampere Maximum Branch UL & CSA Short Circuit Rating — 200,000A IR Maximum Meets 1996 NEC wire bending requirement, section 373-6. CSA - C22.2 No. 0.12 Amp Rating 30 60 100 200 400 Fuses The Proper Fuse Type for the Application is Selected Using the Following Parameters: b Voltage Requirements b Conductor Ampacity b Horsepower Requirements b Maximum Available RMS Fault Current b UL & CSA Fuse Class 240 7.5 15 30 50 – 3 Phase Single Phase DC Volts Volts Volts 240 3 10 15 – – 250 5 10 20 40 50 480 15 30 50 – – 600 20 50 50 – – Maximum VK HP Ratings Amp Rating 30 60 100 200 240 7.5 1.5 30.0 60.0 3 Phase Single Phase DC Volts Volts Volts 240 3 10 15 15 250 5 10 20 40 480 15 30 50 125 600 20 50 75 150 UL & CSA Fuse Classes Interrupting Ratings I2t, Ip Circuits 1-600A 250 and 600V or less AC 10,000A — — Less than 10,000A available 1-600A 250 and 600V or less AC 50,000A — Feeder circuits J 1-600A 600V or less To 200,000A Feeder circuits (motor load small %) RK1 1/10-600A 600V or less 250V or less To 200,000A RK5 1/10-600A 600V or less 250V or less To 200,000A T 1-600A 300 and 600V or less AC To 200,000A L 601-5000A 600V or less To 200,000A I2t-Low Ip-Low I2t-Slightly > J Ip-Slightly > J I2t- > RK-1 Ip- > RK-1 I2t-Low Ip-Low I2t-Low Ip-Low Class H (code) K Lug Amperes Volts is single barrel construction, rated for 2-250 kcmil or 1-500 kcmil cables. 6-42 Fuse clips do not prohibit the use of Class H type fuse in switch. Siemens Canada Limited Power Product Catalogue Feeder circuits (motor load small %) Motor starting currents a factor Non-motor loads Feeder circuits motor loads Panelboards Power and Distribution Selection Type F2 Maximum Unit Panel Space Ampere (MLO) 400A 600A 800A 1200A 30” 45” 60” 60” Box Height 60” 75” 90” 90” 120/240Volts 1 Phase, 3 Wire 120/208 Volts 3 Phase, 4 Wire 600 Volts 3 Phase, 3 Wire 347/600 Volts 3 Phase, 4 Wire Branch Switches 600V Maximum Rating Ampere 30/30A (VK) 60/60A (VK) 100/100A (VK) 200A (VB) 200/200A (VK) 400A (VB) 600A (VB) Maximum Voltage 600V Fusing (1) J, C J, C J, C J, Code, R J J, Code, R,T J, Code, R,T Mounting Height F2 38” W 6.25(159) 6.25(159) 7.5(190) 10(254) 10(254) 15(381) 15(381) Fuse Clip provisions per unit Class T Rating Ampere Rating Ampere 30 60 100 200 400 600 30 60 100 200 400 600 6 Class R PANELBOARDS Single or twin units as listed and are valid for class C or J fuses. If class R or T fuse provisions are required add per table above. Not applicable to VB style units 400A and 600A. Use of auxiliary switch kit will require the use of a 7.5” (190) high unit for 30 and 60 Amp. switches. Refer to Siemens for single phase and DC horsepower requirements. Ratings are based on UL test procedure. CSA will not recognize ratings above 100Hp. Siemens Canada Limited Power Product Catalogue 6-43 Panelboards Modifications and Additions Selection Panelboards Type F2 When required, special constructions or additions to standard panelboards may be specified for all factory-assembled Power and Distribution Panelboards. Below and on the next page are listed many of those available, for Type F2 panelboards. In no case do these apply to Narrow (Column) Width Lighting Panelboards. 1. Miscellaneous 5. Grounding of Non-Insulated Equipment Ground Bus Including Ground Lug Insulated Equipment Ground Bus Including Ground Lug 30 60 75 100 150 200 225 NEMA TYPE Type 1 Type 2 (Drip-proof) Type 3R Type 12 2. Painted Finish Touch-Up Paint (ASA61, Light Gray) 12 oz. aerosol can, Catalog Number TUP-61 Nameplate — laminated, engraved Tamper-Proof Screws 6 4. Devices Mounted on Gutter Cover Includes Device, Mounting — Wired or Unwired PANELBOARDS Unit space 20” Description Toggle Switch — SPST or 3-way; 15A Pilot Light — General Purpose, Neon or Incandescent Phase Neutral Unit Space (inches) 400 400 600 800 600 800 1200 1200 None None None None Ampere Rating 3. Miscellaneous Accessories Ampere Rating 8. Main Bus Standard main bus and ground bus is tin plated aluminum. For copper main bus, neutral bus and ground bus change prefix ‘A’ to ‘C’ on catalog number and contact your sales office for pricing. Unit Space (Additional inches) 3-Pole 2-Pole MLO Consult Sales Office Consult 10 Sales 17.5 Office 10 17.5 11. MLO Compression Lugs Available as main lugs and neutral lug. Deduct From Available Unit Ampere Aluminum Copper Space Rating (Specify Size ) (Specify Size) (inches) 400 600 800 1200 5 5 5 5 12. VK Switch Accessories Item Cat. No. Fuse Pullers (2) 30/60 mp FP2 100 amp FP3 200 amp FP4 13. Sentron TPS (SPD Modules) 100 KA 200 KA 150 KA 250 KA 300 KA Options Surge Counter Remote Indicator 9. Copper Lugs — For Main Lug Only Panels Standard main lugs and neutral lugs are tin plated aluminum, UL & CSA listed for use with aluminum/copper cables. For copper Lugs in the mains and neutral for use with copper cables only, contact sales. Pushbutton For use on main lug, main breaker or main switch panels without subfeed breakers. For increase in panelboard height — Consult local sales office. Ground bar is not installed in box. 6-44 3-Pole 7. Increased Capacity Neutral Description Unit space 20” Siemens CLH Electrically Held 2-Pole 10. Feed-Through (One Set Per Panel) 400 600 800 1200 6. Remote Control Switches 600V AC ASCO 920 600V AC Mechanically Ampere Held Rating 2-Pole 3-Pole Lugs For required unit space — consult local sales office. Price includes increased enclosure height if required. Devices listed by Underwriters’ Laboratories, Inc. When 2 wire control is required. Relay and Terminal Block (9” of unit space required). Siemens Canada Limited Power Product Catalogue For short circuit ratings with remote control switches consult sales office. Panelboard short circuit rating is limited to 5,000 RMS symmetrical. Panelboards Modifications, Additions Replacements for Fusible Switches Selection Replacement Units Amperes Rating 250 Volts Code Fuses Cat. No. 600 Volts Code Fuses Cat. No. 600 Volts J Fuses Cat. No. 600 Volts R Fuses Cat. No. 600 Volts T Fuses Cat. No. 600 Volts C Fuses Cat. No. VK23611CP VK23622CP VK33633CP N/A Height in (mm) VK Switch For Use With FPP6 Panelboards 30/30 60/60 100/100 200/200 N/A N/A N/A N/A N/A N/A N/A N/A VK23611JP VK23622JP VK33633JP VK73644JP VK23611RP VK23622RP N/A N/A N/A N/A VK33633TP VK73644TP N/A N/A N/A V7F3604CP V7H3605CP V7H3606CP V7E3611JP V7E3622JP V7E3633JP V7F3604JP V7H3605JP V7H3606JP N/A N/A N/A V7F3604RP V7H3605RP V7H3606RP N/A N/A N/A N/A V7H3605TP V7H3606TP 6.25 (159) 6.25 (159) 7.5 (90) 10 (254) VB Switch For Use With VB6 Panelboards 30/30 60/60 100/100 200 400 600 N/A N/A N/A V7F3204CP V7H3205CP V7H3206CP N/A N/A N/A N/A N/A N/A 7.5(190) 7.5(190) 7.5(190) 10(254) 15(381) 15(381) Connecting Strap Kits Rating Amperes VB Switch VB6 Cat. No. VK Switch Series 6 Cat. No. 30/30 60/60 100/100 VB6-71 VK6-57 VK6-57 VK6-58 100 200/200 200 400-600 VB6-71 N/A VB6-71 VB6-150 N/A VK6-72 VK6-71 N/A Panelboard Tub Width Depth 9” Panel Type OLD CDP Replacement Max Amps 400 Note MCCB only. 9.75” OLD CDP 600 MCCB only. 32” - 38” 13.75” CDP/VB6 1200A 600A MCCB series 6 connectors “VB” style units only (*) 38” 12.75” SPP/FPP6 1200A 600A MCCB series 6 connectors “VK” or “VB” style (*) 30” - 36” - 42” 6 Blank Plates Height SPP/FPP/CDP/VB 6 1.25” 6FPB01 2.50” 6FPB02 3.75” 6FPB03 5.00” 6FPB05 10.00” 6FPB10 15.00” 6FPB15 For Series 6 Main Devices above 200A, add suffix MS to Catalog Number when ordering. When 2-Pole units are required, use 3-Pole. Series 6 (VB6, CDP6) replacement units and connector kits also accommodates FCI and FCII distributions interiors. Units installed after October 1991 will be FPP6 type. Refer to Siemens for units equipped with auxiliary switches. PANELBOARDS For use with Series 6 CDP Panelboards, S5, F2, FCI and FCII Switchboards. Price is for two brackets – to be included with filler plates. To be used in tubs with 30-200A, VB units or fillers in 125/8” deep tub. Can be used as fillers or in place of circuit breakers, VK or VB Switches. Special order Siemens Canada Limited Power Product Catalogue 6-45 Panelboards Panel Skirts/System Types, AC & DC Voltages Conduit Enclosing Shield (Panel Skirts) AC Voltages Sheet metal to cover conduits above or below a standard panelboard box. 1 phase, 2 wire b 120V 1 phase, 2 wire b 240V 1 phase, 2 wire Skirt Length Width 8, 9, 11, 12 14, 17, 18, 23, 26, 27, 28, 29, 32, 33, 34, 35, 37, 38, 39, 40, 8, 9, 11, 12 14, 17, 18, 23, 26, 27, 28, 29, 32, 33, 34, 35, 37, 38, 39, 40, 25 30, 31, 36 41, 42, 43, 44 25 30, 31, 36 41, 42, 43, 44 Depth 20.00 5.75 20.00 5.75 20.00 5.75 20.00 24.00 24.00 5.75 7.75 7.75 24.00 7.75 24.00 7.75 1 phase, 3 wire b 120/240V 1 phase, 3 wire A B 1 phase, 2 wire, Wye b 277V 1 phase, 2 wire N Panel Skirts Standard Length C 1 phase, 2 wire, Delta b 480V 1 phase, 2 wire A 4 Sides Screw Front B C 8, 9, 10,11, 12, 14, 17, 18, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44 1 phase, 3 wire, Delta b 240/480V 1 phase, 3 wire A B C Busing PANELBOARDS 6 3 b b b phase, 4 wire, Wye 208Y/120V 3 phase, 4 wire 480Y/277V 3 phase, 4 wire 600Y/347V 3 phase, 4 wire A B N C 3 phase, 4 wire, Delta b 240/120V 3 phase, 4 wire b 480/240V 3 phase, 4 wire Single-phase Three-phase phase, 3 wire, Delta 240V, 3 phase, 3 wire 480V, 3 phase, 3 wire 600V, 3 phase, 3 wire 240V, 3 phase, 3 wire, grounded B b 480V, 3 phase, 3 wire, grounded B b 600V, 3 phase, 3 wire, grounded B A B N C 3 b b b b A B C A B N 1 phase, 3 wire, Wye b 208Y/120V 1 phase, 3 wire b 480Y/277V 1 phase, 3 wire C DC voltage N 1 phase, 2 wire b 125Vdc, 2 wire (Up to 125Vdc, MLO option only.) 6-46 Siemens Canada Limited Power Product Catalogue +125Vdc